Loading...
HomeMy WebLinkAbout1000-40.-3-8 L OFFICE LOCATION: ��OF SO(/lyO MAILING ADDRESS: Town Hall Annex P.O. Box 1179 54375 State Route 25 * Southold, NY 11971 (cor. Main Rd. &Youngs Ave.) Southold, NY 11971 G� Q Telephone: 631 765-1938 Fax: 631765-3136 �y00UNTY, LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD MEMORANDUM To: Jim King, President Town of Southold Board of Trustees From: Mark Terry, Principal Planner LWRP Coordinator Date: September 13, 2012 Re: Proposed Wetland Permit for RICHARD WINDMULLER & CAROLINE ROCCHETTA SCTM#1000-40-3-8 GreenLogic LLC on behalf of RICHARD WINDMULLER & CAROLINE ROCCHETTA request and Administrative Permit to install a ground mounted solar electric system. Located: 285 Queen Street, Greenport. SCTM#40-3-8 The proposed action has been reviewed to Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to me, it is my recommendation that the proposed action is EXEMPT from LWRP review pursuant to: § 268-3. Definitions. MINOR ACTIONS item "G" which states: G. Minor temporary uses of land having negligible or no permanent impact on coastal resources or the environment; Pursuant to Chapter 268, the Board of Trustees shall consider this recommendation in preparing its written determination regarding the consistency of the proposed action. Cc: Lori Hulse, Assistant Town Attorney Town of Southold LWRP CONSISTENCY ASSESSMENT FORM A. INSTRUCTIONS 1. All applicants for permits' including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. "Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. 2. Before answering the questions in Section C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the To of Southold Local Waterfront Revitalization Program. A proposed action will be evaluated to its significant beneficial and adverse effects upon the coastal area(which includes all of Southol To 3. If any question in Section C on this forth is answered "yes", then the pro may affect the achievement of the LWRP policy standards and conditions contained in i cy review law. Thus, the action should be analyzed in more deen I ed prior to making a determination that it is consistent to the mah le the LWRP policy standards and conditions. If an action cannotnsistent wt the LWRP policy standards and conditions,it shall not be undertak A copy of the LWRP is available in the followt the Town of Southold's website(southoldtown.northfork.net), the Boarlocal libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION AUG - 8 2012 scTM# IDOU _ 40 _ 5 southhold Town The Application has been submitted to(check appropriate response): Board of Trustees Town Board © Planning Dept. 7 Building Dept. [3 Board of Trustees 1. Category of Town of Southold agency action(check appropriate response): (a) Action undertaken directly by Town agency(e.g.capital AUP 1 2012 construction,planning activity,agency regulation, land transaction) (b) Financial assistance(e.g.grant,loan,subsidy) (c) Permit,approval,license,certification: ®/ Nature and extent of action: I n sla ( l Qrt)1,i,rJ m ouni S o la�e sis-6ry-) Location of action: a g S Q(.lEtV1 S1-F ✓ f Site acreage: 0• C1 tG S Present land use: '(.R 51 /1 C�- t aa n Present zoning classification: eS l drn-6 �- nen -C OrAr V-+t Nt9 2. If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: �/// II (a) Name of applicant: win�Mkj�er/Kocr-keft (b) Mailing address: (c) Telephone number: Area Code( ) (d) Application number,if any: Will the action be directly undertaken,require funding,or approval by a state or federal agency? Yes ❑ No ff If yes,which state or federal agency? DEVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space,makes efficient use of infrastructure,makes beneficial use of a coastal location,and minimizes adverse effects of development. See LWRP Section III-Policies; Page 2 for evaluation criteria. ❑Yes ❑ No ►dNot Applicable Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LV;"Section III-PPollicIes Pages 3 through 6 for evaluation criteria 13 YesEl No Ef Not Applicable Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section III—Policies Pages 6 through 7 for evaluation criteria Yes Q No Not Applicable Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III—Policies Pages 8 through 16 for evaluation criteria 13 Yes D No WNot Applicable Attach additional sheets if necessary Policy S. Protect and improve water quality and supply in the Town of Southold. See LWRP Section III —Policies Pages 16 through 21 for evaluation criteria 0 Yes E] No allot Applicable Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife habitats and wetlands. See LWRP Section III—Policies; Pages 22 through 32 for evaluation criteria. Yes Q No R Not Applicable Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III — Policies Pages 32 through 34 for evaluation criteria. 0 YesDNoEjjrNot Applicable Attach additional sheets if necessary Policy S. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III—Policies; Pages 34 through 38 for evaluation criteria. Yes ❑ No ULi Not Applicable PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III—Policies; Pages 38 through 46 for evaluation criteria. nn ry ❑ YeD No E Not Applicable Attach additional sheets if necessary WORIONG COAST POLICIES Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section III—Policies; Pages 47 through 56 for evaluation criteria. Q Yes ❑ No 9Not Applicable Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section III—Policies; Pages 57 through 62 for evaluation criteria. 13Yes ❑ L�No Not Applicable Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III —Policies; Pages 62 through 65 for evaluation criteria. 0 Yes ❑ No L2 Not Applicable Attach additional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral. resources. See LWRP Section III—Policies;Pages 65 through 68 for evaluation criteria. Q Yes ❑ No Not Applicable Created on 512510511:20 AM SURVEY OF PROPERTY N AT ARSHAMOMOO UE . +� STONE N TOWN OF SOUTHOLD SUFFOLK COUNTY, N. Y. 1000-40-03-08 fiG \ Y y o SCALE.- 1'-30' Q� y o APRIL 30, 2009 UNpUSKpS60 P' y y n pg� N/O/F M• Mp 221' ECEOWEcs 11 � SuSpN a 's y y 03o D D 2 MARY pNN BOKEN y y m y y AUG - 8 2012 NCE % w Southhold Town N 56,30E X aE INCE I y Board of Trustees o p / y _ ROD x k b N y WETLANDS y ^ Y Z x _ m I—X-lx X X Im y C p "b. ('7 `7 Z Vl � SPS g I y � n 6 I y r+T 5 O2 Ry y CERTIFIED T0: �aEs yopME HN y RICHARD WINDMULLER FR CAROLINE ROCHETTA 1` 0 CONC � sF a CONTINENTAL HOME LOANS y y y B/RDGER ABSTRACT, LLC 1 pdrvEµav` �� STEWART TITLE INSURANCE COMPANY SHELL y y 236,15 y N m e i y 0. N y AREA=39,5 yFT. r+ FENCE cx�%� MErZCs 'y wvn� scot. � y .t. ,x X,,. T1J AL) B(OG �O � pC (DELAP.) INS � ,x S7g•,}2.5�,W((DEED) SEVEN p� '� N. Y.S. LIC. NO. 49618 , S75 42 0� �ENORE & - R5, P.C. N/ ANY ALTERATION OR A0011]ON TO THIS SURVEY /S A VOCATION FAX (631) 765-1797 - OF SEC77ON 7209OF THE NEW YORK STATE EDUCATION LAW. EXCEPT AS PEP, SECTICN 7209—SUBDIVISION 2. ALL CERTIFICATIONS R STREET HEREON ARE VALID FOe' THIS MAP AND COPIES THEREOF ONLY IF 09_1�6 SAID AlAP OR COPIES PEAR THE IMPRESSED SEAL OF THE SURVEYOR so MY 11971 v WHOSE SIGNAT::IRE APPaARS HEREON. 2 Strings of 6 SunPower 327 W panels, Each string 1962 watts I Array total of 3924 Wafts r All panels to be grounded as per NEC code 2,30 AMP two pole DC switches from panels to inverter F F SUNPOWER SPR 4000m INVERTER 240 VAC pffAUG WE 240 VAC from inverter to a 30 p Amp switch near utility meter 2012 Southhold Town Board of Trustees Gt GREENLOGICO ENERGY ELIMINATING THE COST OF ENERGY Ground Mount GreenLogic, LLC Proposed 3.924 kW Panel Dimension = 41.18"x 61.39" 12 SunPower 327W Array Length = 247.08" SunPower 327W Winmuller, Richard DPW Ground Mount Array Height= 285 Queen St Azimuth = 1800 Surface Dimensions = Greenport, NY 11944 Pitch = 20° Magic#_ Scale 3/16° = 1.0' DPW Ground Mount Layout Created By: CDH Date: 4.18.12 Energy Consultant: JPHS SUNPOWERE20/327SOLAR P. 20% EFFICIENCY SunPower E20 panels are the highestJ. efficiency panels on the market today, providing more power in the some amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest- efficiency panels with the highest-efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels per install. This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Moxeoni°'cell THE WORLD'S STANDARD FOR SOLARTv technology and advanced module SunPowerr E20 Solar Panels provide today's highest efficiency and design ensure industry-leading reliability performance. Powered by Sum Power Maxeonr°' cell technology, the E20 series provides panel conversion efficiencies of up to 20.1%. The E20's low voltage temperature coefficient, anti-reflective glass and exceptional low-light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% 15% 10% _ 5% Aft THIN FILM CONVENTIONAL E PEZ E7I�1 MAXEON M CELL SERIES SERIES SERIES TECHNOLOGY sunpowercorp.com Patented all-back-contact solar cell, providing the industry's highest O efficiency and reliability g V� US SUNPOWERSOLAR P. MODEL: SPR-327NE-WHT-D ELECTRICAL DATA IN CURVE Aluwred.1 anda,dTw1Cous.[STCI:mad.d 1"W/e'."15,aiM.11.,amvue 25°c Peak Power(+5/-3%) Pmax 327 W 7 1000 W/ 6 1111ow/m= Cell Efficiency n 22.5% 5 Panel Efficiency It 20.1 % 4 goo w/m Rated Voltage VmPP 54.7 V 3 Rated Current ImpP 5.98 A V 2 50OW/na Open Circuit Voltage Va 64.9 V 1 201Short Circuit Current Isc 6.46 A 0 Maximum System Voltage UL 600 V 0 10 20 30 40 50 60 70 Temperature Coefficients Power(P) -0.38%/K Current/voltage characteristics with de{wnda�ence oonModlance and module ternosonam. Voltage(Va) -176.6mV/K Current(I.) 3.5mA/K TESTED OPERATING CONDITIONS NOCT 45a C+/-2'C Series Fuse Rating 20A Temperature -40'F to+185°F I-40a C to+85'C) Grounding Positive grounding not required Max load 113 psf 550 kg/012(5400 Pa),front(e.g.snow) w/specified mounting configurations MECHANICAL DATA 50 psf 245 kg/012(2400 Pa)front and back (e.g.wind) Solar Cells 96 SunPower Maxeon`m cells Front Glass High-monsmission tempered glass with Impact Resistance Hail: (25 mm)at 51 mph(23 m/s) anti-reflective(AR)coating Junction Bax IP-65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm WARRANTIES AND CERTIFICATIONS Output Cables 1000 mm cables/MulttConact IMC4)connectors Warranties 25-year limited power warranty Frame Anodized aluminum alloy type 6063 (black) 10-year limited product warranty Weight 41.0 lbs(18.6 kg) Certifications Tested to UL 1703.Class C Fire Rating DIMENSIONS 2X 11,0[431 MM (A)-MOUMING HOLES (B)-GROUNDING HOLES33(118] —{ i�a577[MMI iso 17,071 (IN) la 06.6[.26) 10x0411.171 CJI 322[12.69] ,X=A[9.091 Is m B2B 3 1H _ ry 1 n — 1559161391 4611411 +I (A) 915[MWI 1200[4754[ 12[471 15"I ui'5] Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. 02011 SuWa rCwpo .SUNMWER,Aw SoNo rL9 .aMTHEW W'SVANDARDFORS ,md M4XEONannadwarlaw,plrlemdn arm, sunpowercorp.com d SunPawx Ca,pwmba In dm US and akar wunnim ar wall.AR Righa Rwvd.Spcikdion.iwLdd in this dmaahr on r,bha a large wWwm m1ne. Dwumem#00145464 Rar•8/RR_EN a 11_"6 SUN • • • 3000m • • 4000m INVERTERS EXCEPTIONALD PERFORMANCE BENEFITS - Reliable and Robust Design Proven track record for durability and longevity High Efficiency Weighted CEC efficiency over 95% and peak efficiency over 96% Reduced Installation Cost Integrated DC disconnect with fuses _' lowers material costs and labor requirements Attractive Aesthetics Integrated disconnect eliminates need for visible conduits to inverter Ideal Output Ideal for residential applications SunPoweri° 3000m and 4000m Inverters offer exceptional reliability and superior performance. Innovative design and advanced testing are combined to create a durable inverter for optimal system performance over the long term. Both models are backed by a standard 10-year warranty. SPR-3000m and SPR-4000m sunpowercorp.com 1-800-SUNPOWER SUN • • WER 3000m and 4000 ' EXCEPTIONAL •' Electrical Data SPRm Efficiency Curves loo SPR-3000m SPR-4000m 95 250 Vda AC Power 3000 W 3500 W 0 208 V 4000 W 0 240 V 480 Vrk v 85 AC Maximum Output Current 15A,13A 17A t,E 80 I@ 208V,240V) 75 AC Nominal Voltage/Range 183-229 V 0208 VAC 183-229 V0208 VAC 70 211-264 V 0240 VAC 211-264V0240VAC 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% %of Rated Output Power AC Frequency Range 60 Hz/59.3 Hz- 60 Hz/59.3 Hz 60.5 Hz 60.5 Hz Mechanical Data Power Factor 1 1 Shipping Dimensions W x H x D(inches) 23.5'x 18.5-x 160' Unit Dimensions W x H x D(inches) 17.8"x 13.8^x 9.3' Peak Inverter Efficiency 96.5% 96.8% Inverter Weight 88 lb, CEC Weighted Efficiency 95.0%0208V 95.5%0208V Shipping Weight 9A lb, 95.5%0 240 V 96.0% 240 V Forced Air/Sealed Cooling Electronics Enclosure Recommended Array Input 3750 W 4375 W 0 208 V Power(DC @ STC) 5000 W 0 240 V Enclosure NEMA 311 Mounting wall Mount Bracket Standard DC Input Voltage Range 200-500 V 0208V 250-600V 0208 VAC 200-500 V 0240V 250-600V 0240 VAC Ambient Temperature Range -13 to+113-F Peak Power Tracking Voltage 175-400 V 0208 VAC 220-480 V 0208 VAC Warranty and Certifications g g 200-400V 0240 VAC 250-480 V0240 VAC Warranty 10 year limlbd.,only DC Max.Input Current 17 A 18 A Certifications Compliance:IEEE-929,IEEE-1547,UL 1741-200.5, UL 1998,FCC Pan 15 A 8 0 DC Voltage Ripple <5% No.of Fused String Inputs d it Power Consumption: <7 W/0.1 W Standby/Nighttime O Fused DC Disconnect Standard;Complies w NEC Standards DD Configurable in the field with integrated grounding kit: Electrical Grounding SunPower-Solar Panels:DC circuit posevely grounded Serengeti-Solar Panels:DC circuit uegai grounded About SunPower Founded in 1985, SunPower Corp. (Nasdaq: SPWRA, SPWRB) designs, manufactures and delivers the planet's most powerful solar technology broadly available today. Residential, business,government and utility customers rely on the company's experience and proven results to maximize return on investment. SUNPOWER and IM Sl1NPOWER kgo vra ncd—n or m,remA nademmka d SunPower Cursum ur, .Sun powercorp.cO rn ®wmh]010 SunPawx Coryvanon NI dgM1e nerved SpaalkcaRonr iiuluded in thlr dorosMel ore rubl.a ro cho,ge wlAwt w<e. OmmsuY001-16946,Aar•A Pacifico Engineering PC _. _ Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 . MM Iff� Fax: 631-382-8236 www.pacficoengineering.com >,r:M� engineer@pacificoengineering.cam m July 26, 2012 ) r= ( , , [ Town of Southold Building Department 54375 Route 25, P.O. Box 1179 `' AUG - 8 2012 L� Southold, NY 11971 Subject: Solar Energy Installation for Snuthhoid Town Richard Windmuller Section: 40 Board of Trustees 285 Queen Street Block: 3 Greenport, NY 11944 Lot: 8 1 have reviewed the proposed renewable energy installation at the subject address.The structure can support the imposed live and dead loads.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. The climactic and load information is below: CLIMACTIC AND Ground Wind Live load. GEOGRAPHIC DESIGN Category Snow Load, Speed,3 pnet30 per CRITERIA pg see gust, ASCE 7, mph psf Ground Mount A C 20 120 21 Solar Array l� s Ralph Pacifico, PE Professional Engineer jl�b Raiic6[.AadM(�'1dqoEnoinaer ray ON11 1t3�scE04744306 LOGIC ELIMINATING INE COSI Oi ENERGY X\ XXXXX xxxxxx DRAWING NUMBER: PSAW Enp woft PC 1 OF 3 Pt=�0es'om�o s.k W nm GROUNDMOUNT LAYOUT •Alva s double check measurements ' '1NNIX(1X182WIJC24GW4M GreenLogic, LLC —Approved 3.924kw Panel Dimension =61.39"x41.18" Layout 12 SunPower 327w i%��CF�N—�; Array Length = 252.08 t W y " DPW Ground Mount Array Height = 122.78" / eH ' ' Richard Windmuller Azimuth = 180° 'e <" Surface Dimensions = N/A e�� 285 Queen Street Pitch = 30' Magic#= N/A Green ort, Ny Scale 3/16" = 1.0' PON /L ISSUE /SPECIAL NSTR TIONS PROJECT COMENT COUNT � A)Attachment type and count: Sunpower 327w ,\ • Attachment Point B) Rail type and count: DPW Ground Mount DPW Power Rail a h ac c'o `ro essiona n ineer Layout Created B : MVP Date:7-12-12 Nrs Elrl08fiT921y1i� eRTeona�Yao LOGIC \ A\ /1\\ /1\ /1 ELIMINATING THE C051 GE ENERGY / \Y 7 _F_j__\X/ txtZ x1x T „V," M Ground Mount Specifications j Panel = SunPower 327w Panel Dimension =61.39"x 41.18" GM Array Pitch = 30 degrees Concrete Footing Dimensions = 30"x48" Front Leg Height Above Ground = 9" Rail = DPW Power Rail P8 1_ AO0 I CarcfeM Foo@p F.MV DRAWING NUMBER: PedhO Engk" p PC 2 OF 3 roON140.8WAftWiIM GROUNDUNT DETAIL ".,N•Aiwa s double check measurements MOw�c**. " GreenLogic, LLC—Approved 3.924kw Panel Dimension =61.39"x41.18" Layout 12 SunPower327w ;r tuE �•, Array Length = 252.08' DPW Ground Mount Array Height = 122.78" ; ' i `?.N\ Richard Windmuller Azimuth = 180° Surface Dimensions = N/A d, ' 285 Queen Street Pitch = 20" Magic# = N/A = I i; Greenport, NY NOT TO SCALE ISSUES I SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT Sunpower 327w A)Attachment type and count: \\•'L. �. rJ°/I Z;� 'ji • Attachment Point B) Rail type and count: DPW Ground Mount DPW Power Rail a ac a n (neer NYS Emr min W W02�047M 00 Layout Created BY: MVP Date:7-12-12 LOGIC' I LIMINVINC THE COST Of ENCNGY - xxx X__ x DRAINING NUMBER: Pads -PC P09R 14M.8yri,w ilm 3 OF 3 031iM�08 OUNDMOUNT STRING' 2x6 on SPR4000m 'Aiwa s double check measurementsf m�'md WIA GreenLogic, LLC—Approved 3.924kw Panel Dimension =61.39"x41.18" F ; ?, Layout 12 SunPower 327w Array Length = 252.08" DPW Ground Mount Array Height= 122.78" Richard Windmuller Azimuth = 1800 Surface Dimensions = N/A 285 Queen Street Pitch = 30° Magic#= N/A ( j Greenport, NY Scale 3/16" = 1.0' ISSUES rSPECIAL INSTRUCTIONS r PROJECT COMPONENT COUNT Sunpower327w A) Attachment type and count: , Attachment Point B) Rail type and count: DPW Ground Mount DPW Power Rail _ff >J`°_ _F_` a aC o ro ss'ona n (neer Mvs uoe aesiaz w Iiol s�aTusao Layout Created By: MVP Date: 7-12-12 %rJ NF; , END CLAMP TYP. SPR327 MODULE P14 STRONGBACK / , 1 TYP. n RAIL BRACKET 123.01" TYR .25" 61.38" MODULE LENGTH 79.53" TYP.j i� /i G' 30' 9" SUPER POST 17" 48" .: e • 4. ' DIRECT POWER AND WATER 0000 VASSAR DRIVE NE ALBUQUERQUE.NEW MEXICO 87107 30" 96" DPW m. P8-TTRGMI2-G SUNPOWER- SOLAR SPR327-OP-30•-120MPH-25PSF SIDE VIEW GREENLOGIC ^ CML nw 7-1342 J.R. J.T. 1 ,.,..Mrrs"..�.. NBNDMULLER ru.anro A%.; 252"FINAL CUT(2 z 12W=257 STANDARD LENGTH) SPR327 MODULE MODULE 7 .vil L WIDTH ?PIIf P8 POWER RAIL TYP. TYP. \ i 61.38" MODULE LENGTH MID CLAMP TW. TYP. PS POWER RAIL TYP. P14 POWER -� RAIL TYP. END CLAMP P8POWER TYP. RAIL TYP. �• t 1 1 ..'" 32"MAX. " (4 STRONGBACKS) DIRECT POWER AND WATER 4000 VASSAR DRIVE NE FRONT VIEW ALBUQUERQUE.NEW MEXICO 87107 DPW " P8-TTRGMI2-G-SUNP0WER- SOLAR SPR327-OP-30'-120MPH-25PSF GREENLOGIC CML o,n 7-13-12 vnoxcr e�". J.R. ".n 2 WINDMULLER .a"maae�o H,.wrrew�. Wi��yYf Yl"AIO J_ 5/16"TURN BOLT 8 FLANGE NUTS moi, 3"x1.5"x.130" ALUMINUM CHANNEL P6 POWER RAIL SEE P14STRONGBACK VIEW A VIEW A LEG 3"x1.5'k130" ALUM.CHANNEL CROSS BRACE P6 POWER RAIL (EVERY OTHER BAY) 64"TYP. 4LEGS BACK VIEW DIRECT POWER AND WATER (PARTIAL, NOT TO SCALE) 40W VASSAR DRIVE NE ALBUQUERQUE,NEW MEXICO 87107 DPW n— PS-TTRGM 12-GSU NPOW ER- SOLAR SPR327-OP-30"-120MPH-25PSF GREENLOGIC � CML art_ 7-13-12 wo« `"'�". J.R. 3 WINOMULLER