Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
36862-Z
Town of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 10/1/2012 No: 35981 Date: 10/1/2012 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: ACCESSORY GARAGE 440 JERNICK LANE SOUTHOLD, Sec/Block/Lot: 70.-3-18 Filed Map No. conforms substantially to the Application for Building Permit heretofore 11/20/2008 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: 12 'X 26' ~arage addition to an existing one family dwelling as applied for. Lot No. filed in this officed dated 36862 dated 12/7/2011 The certificate is issued to RONALD & JEAN YEDLOUTSCHNIG (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 36862 9/20/12 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 36862 Date: 12/7/2011 Permission is hereby granted to: RONALD & JEAN YEDLOUTSCHNIG 440 JERNICK LANE SOU~I-IOL. D~ Ny ~ 1971 To: CONSTRUCTION OF A 12'X 26' GARAGE ADDITION AS APPLIED FOR.REPLACES EXPIRED B.P. # 34317 At premises located at: 440 JERNICK LANE SOUTHOLD SCTM # 473889 Sec/Block/Lot # 70.-3-18 Pursuant to application dated To expire on 617/2013. Fees: 11/20/2008 and approved by the Building Inspector. PERMIT RENEWAL Total: $100.00 $100.00 Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Mall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERi, IT NO. 34317 Z Date NOVEMBER 25, 2008 Permission is hereby granted to: RONALD YEDLOUTSCMNIG 440 JERNICK LA SOUTHOLD,NY 11971 for : CONSTRUCTION OF A 12'X 26' GARAGE ADDITION AS APPLIED FOR at premises located at 440 County Tax Map No. 473889 Section 070 pursuant to application dated NOVEMBER Building Inspector to expire on MAY JERNICK LA SOUTMOLD Block 0003 Lot No. 018 20, 2008 and approved by the 25, 2010. Fee $ 200.00 Authorl Jed Sigriature COPY Rev. 5/8/02 Form No. 6 TOWN OF SO1JTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCcupANcy This application must be filled in by typewriter or ink and submitted to the Building Department with the following: For new building or new use: 1. Final survey of property with acCUrate'location of all buildings, property lines, streets, and unusual natura} or topographic featur6s. 2. Final Approval from Health D~pt. of water supply and sewerage-disposal (S-9 form). 3. Approval ofelectrieal installation from Board 0fFire Underwriters. 4. Sw.orn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance'from architect or engineer responsible for the building: 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and. unusual natural or topographic features. 2_ A properly c4?mpleted application and cor~sent to inspect signed by the applicant. If a Certificate of Occupancy ia denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certifica[e of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimmir~g pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00~. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of.Occupancy- $:25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: Old or Pm-existing Building: ~ Location of Property: /-~qc0 x..jcg, t~nlCk l~.~na.~.. House No. Street · Owner or Owners ofPreperty: .~0'3q~ ~._ + -~ dLa~. - Suffolk County Tax Map No 1000, Section '-~) Subdivision P~rmit No. 3(J9 ~t ? Date of Permit. Health Dept. Approval: (check one) Block ~ Lot Filed Map. Applicant: Underwriters Approval: H~a let Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Final Certificate: (cheek one) Applicant Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southo}d, NY 11971 0959 Telephone(631)765-1802 Fax(631)765-9502 roger.riche~C, town.southold.ny.us BUILDING DEPARTMENT TOWN OFSOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: R & J Yedloutschnig Address: 440 Jernic Lane City: Southold St: NY Zip: 11971 Building Permit #: 36862 Section: 70 Block: 3 Lot: 1~ WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Elec Tec Inc License No: 4814-me SITE DETAILS Residential Commedcal New Addition Service 1 ph Service 3 ph Main Panel Sub Panel Transformer Disconnect Other Equipment: Office Use Only Indo°r F~ Basement ~ Service Only~ Outdoor 1st Floor Pool Renovation 2nd Floor Hot Tub Survey Attic Garage INVENTORY Hot Water GFCI Recpt NC Condenser Single Recpt A/C Blower Range Recpt Appliances Dryer Recpt Switches Twist Lock Ceiling Fixtures [~ HID Fixtures Wall Fixtures I 11 Smoke Detectors Recessed Fixtures[~ CO Detectors Fluorescent Fixture ~.~ Pumps Emergency Fixturesl.__~ Time Clocks Exit Fixtures [__~ TVSS Notes: Inspector Signature: Date: Sept 20 2012 81-Cert Electrical Compliance Form.xls TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ] ROU~PLBG. [ ]FOUNDATION 2ND [ ]~.~OLATION [ ]FRAMING/STRAPPING [~/J FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) _ [ ] ELECTRICAL (FINAL) REMARKS: /~/~~/~OWN ~ INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ~ELECTRICAL (FINAL) REMARKS: DATE -~~ INSPECTO~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO.~GH PLBG. [ ] FOUNDATION 2ND [ ]~I~ULATION [ ] FRAMING/STRAPPING [~/] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE ~:'~:/~ INSPECTOR ~~L~/~ Date: To: Re: JAMES J. DEERKOSKI P.E. 260Deer Drive Mattituck, NY 11952 (631) 774 7355 September 17, 2012 Town of Southold Building Dept Garage Yedloutschnig 440 Jemick La. Southold, NY 11971 Permit#36862 To Whom It May Concern: This lett~ertifies that the foundation~ fr~ rang and wind strapping at the above mentione~b~age addition was constm[tecs per submitted plans, and in conformance with all Sta~e ~ ~s. Any quos ~s feel free to call. //~/~X~ ~ , - ly, ~~~~~f~ ~ James~eerkoskiP.E. FIELD INSPECTION IIEPORT ~OUreOXT~ON oST) ~.~ FO~DATION (2ND) ROUGH F~G & PER N- Y. ~S.~ATION STATE ENERGY CODE [~//9 / / /~/- ~ ., F~ ~D~ON~ CO~S ,./ -/- , ~o . Town Southold ErosEon, Sedimentation & Storm-Water Run-off ASSES8MENT FOI~M PROPERTY LOCATION: S.C.T.NL #: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A I)~stric{ Sec[ion ~3~ock Lot CERTIFIED BY A DESIGN PROFESSIdNAL IN THE STATI-= ~F NEW Y0~, (NOTE: A Check Mark (~) for each Question is Required for a Complete Application) Yes 1 Will this Project Retain All Storm-Weler Run-Off Generated by a Two (2") Inch Rainfall on Site? (This item will include all run-off created by site clearing and/er construction activities as well as ail Site -- Improvements and tile permanent creation of impervious sur[eoes,) / 2 Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location? This I~em shall include ell Proposed Grade Changes and Slopes Controlling Sudace WaterFIowl -- ~raber: Will Ihis Projecl Require any Land Fill, lng, Grading or Excavation where Ihere is a change 1o the Natural Existing Grade Involving more than 200 Cubic Yards of Matedal within any Parcel? 3 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess Five Thousand (5,000) Square Fee of Ground Surface? 4 Is there a Nalural Water Course Running through Ihe Site? Is [his Project wifllin lhe lruslees jurisdiction or withirl One Hundred (100') feet cfa Wetland or Beach? 5 Will Ihere be Site n~ paration on Exisling Grade Slopes which Exceed Fifteen (15) teal or Vedical Rise One Hundred (100') of Horizontal Distance? 6 7 Will this P~oject Require tht; Placement of Material, Remo,cal of Vegelation and/or the CorlslnJclio¢~ of anyllenlVCdhinlll( To'¢,nRight of Way or Road Shoulder Area? (This ilem will NOT include the Installation of Driveway Aprens.) 8 9 Will this Prmi(ctRequ(r~ Sfle Prepa~a[ion wilhm the One Hundred (100) YearFIoodplah~ofanyVVatercourse? NOTE: If AnyAnsv, er to Questions One throughl,iine is Answered with a Check Mark in the Box, a Storm-Water, Grading, EXEMPTION: Ye~s Does this projecl meet the minimum slandards for classification as an Agdcultural Project? STATI,; OF NEW YOI~K, o1 0 ,ss Owue~ and/et reprcsenctuxc of fl~ 0 I e of ()~ ae~ s, m~d Is ch]Iv aud~orlzed to perfoun or Ilex,re petfummd ~e sad %5r01[ aod to make:: al~d file riffs apptica~on; d~a( Mi slatement,s (:unmincd m this applicaaon are bxte to thc best o[his ~owledge and belief; and ~at fl~e work will be pel fo~ reed m iix, m;mm:r set ~ordt in dee application filed he~ewi~ Sworn to before n~e FORM - 06107 ~mmission ~pir~Juy28, Town I-Iall Am,z~ 54375 Main Ro~i P.O. Box 1179 · Sou~ ~ 11971-0959 T,d~ (~1) 765-1802 BUH~ING DEI'A.R'DJENT TOWN O1~ SOTJTHO!.r~ APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Company Name: ~_~.l~c.._ ~-~-_C_ Name: License No.: Address: Phone No.: *Name: *Address: *Cross Street: *Phone No.: Permit No.: Tax Map District: JOBSITE INFORMATION: (*Indicates required information) 1000 Section: ~ Block: ,'~ *BRIEF DESCRIPTION OF WORK (Please Print Clearly) (Please circle All That Apply) *Is job ready for inspeclion: *Do you need a Temp CerGficate: Temp'information (If needed]. *Service Size: I Phase 3Phase *New Service: Re-connect Additional Information: 82-Reque~ for Inspection Form ( NO Rough In Final 100 150 200 300 350 400 Olher Underground Number of ~ Change of Service Overhead PAYMENT DUE WITH APPLICATION Southold Town Building Department 54375 Main Road Southold, New York 11971 (631) 765-1802 Parcel ID: 70.-3-18 Permit #: 34317 Permit Date: 11/25/2008 Expiration Date: 5/25/2010 BUILDING PERMIT RENEWAL LETTER Applicant: Location: Work Description: Dated: 11/22/2011 RONALD & JEAN YEDLOUTSCHNIG 440 JERNICK LANE SOUTHOLD ACCESSORY GARAGE CONSTRUCTION OF A 12'X 26' GARAGE ADDITION AS APPLIED FOR A FEE OF $100.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Address: RONALD & JEAN YEDLOUTSCHNIG 440 JERNICK LANE SOUTHOLD, NY 11971 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All work on the project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. TOWN OF SOUTHOLD PROPERTY RECORD CARD ,OWNER STREET //~/Z~/~) VILLAGE DIST. SUB. LOT ~. FORMER OWNER N E ACR. · ', RES. S~S. U VL. FARM CO~. CB. MlCS. Mkt. Valu. ~ND IM~. TOT~ DATE R~RKS o~'~oo~ ~'-~' '~- ' ' AGE BUlLQING CONDITION NEW NOeL BELOW ABOVE FA~ Acre Valu~ P~t , Acre Tillakl~ FRONTAGE ON WATER W~lond FRONTAGE ON ROAD M~dowl~d DEPTH Hous~ Plat BULKH~D Tatal COLOR M. Bldg. Extension Extension Extension Porch Breezewoy Garage Patio ~ Toro! Foundation Basement /~ 0 ~Ext.'Walls Fire Place Type Roof Recreatio~ Room Dormer Bath Floors Interior. Finish Heot Rooms 1st Floor Rooms 2nd Floor Driveway / ~. Dinette S~ .~K. DR' BR. FIN. B LOT AREA~ ,~?,~1.'1 ~. 1~. cJ / · ~ ~'~ 127.~' [ '" ": ~ ~ ~. 1~7~ ~ 12-~7-2~1 O~D ONLY ~: ~E ~ ~. ~ROLD F. T~HON JR. P.C. ~ND S~OR ~ YORK, 1~92 F k CERTIFICATION REOUIRED. RL~UIREMENI'8 co~so~w yo~ OCCUPANCY OR USE IS U~W~L ~.ow.~ AP~OV~ED AS NOTED ~" CCA ,-~zq ~ ~ ~ BY'_ ~E:~ DEPARTME~ ~ ~G ~SPECTDNS: ~. ~DA~ - TWO ~ R~ ' ~ING & PLU~G ~ ~T~ ~ ~. ~TPtJCT~ ~ ~ m~ c.o. r~ FRONT ELEVATION SCALE: 1/4": 1'-0" NEW EXIST REAR ELEVATION SCALE: 1/4" = 1'-0" OCCUPANCY OR OFC" AP?ROVED AS NOTED ~4 r, H phone: (631) 298-2250 e-mail: michael@ mchdesignservices.com rTl m DRAWN BY: MH November 16, 2008 ~iATER RU'~ PURSUANT TO CHAPTER 2 r-.,I OF THE TOWN CODE, i N U JNDERWRIER~ j~F,,, DATL I RIGHT ELEVATION SCALE: 1/4" = 1'-0" M n H www.mchdesianservices,com phone: (631 } 298-2250 .--mail: rnichaeJ@ mchdesig nser~ices.com DRAWN BY: MH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NOI :XISTINGI EXISTING EX~STING FOUNDATION PLAN SCALE: 1/4" = 1'-0' ~ n H phone: (631) 298-2250 e-mail: mlchael@mchdeslgnservices.com DRAWN BY: MH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NOi XISTIN( ] EXZS'rzNG EXISTING FLOOR PLAN SCALE: 1/4" = 1'-0' 'F mm GARAGE ~ C H Design Services (631) 298-2250 e-maih mlchael~ mchdes[gnservices.com DRAWN BY: NH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NO[ EXISTIN~ EXISTING i ROOF PLAN SCALE: 1/4" = 1'-0' NI ~, H phone: (631) 298-2250 a-mail: michael@ mchdesrg nservlces.co m r.~ rTl ~ I I DRAWN BY: MH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NOI / o (EXISTING) rPc CONRETE SLAB FOUNDATION SECTION A-A SCALE: 1/4" = 1'-0" fi' /~/,/I i/ , i*llll// '/ ! /ilar , , 1 WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAl AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION ~ WINDBORNE DEBRIS PROTECI]ON FASTENING SCHEDULE FOR WOOD STRUCTURAL PANEl-C; WOOD STRUCTURAL PANELS WTrH A MINIMUH THTCKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMTITED FOR OPENING PROTECTION IN ONE- AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WTrH AITACHHENT HARDWARE PROVIDED. (REFER TO SECTION 1609.:L4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RE_~DENTIAL CONSTRUCT[ON CODE). THIS IS NOT A SUB~ i t i uT[ON FOR DESIGN-PRESSURE. ALL OPENINGS HUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE. ALE PANELS IqUST BE OJT TO SIZE AND READY TO USE ON ANY NEW W[NOOWS AND DOORS. SHu I I ~N~ MUS-I' BE HARKED FOR WHAT OPENING [T IS TO (]OVER. HARDWARE HUST ACCOHPANY SHLITIERS FOP, INSTALLATiON. M C H Desion Services www. mchdesiQnservices.com ,hone: 331) 298-2250 mail: michaelL~mchd eslgnservlce$.com DRAWN BY: MH November 17, 2008 SCALE: 1/4" = 1'-0" SHEET NOI STORM WATER MANAGEMENT DETAILS N.T.S. OGEE GUl~ER - STANDARD 5" NEW ROOF AREA: sqo SQ. FT. AT 100% WATER RUNOFF: 65.2 CU. FT, PROVIDE :11) g'X2' DEEP DRYWELL [OR EQUAL] DRYWELL CAPACITY: 8'4-.5 CU. FT. EXISTING EXISTING I M P, H Design Services www,mchdesionservices.com phone: (631) 298-2250 e-maih michael@mchd esig nservices.com DRAWN BY: MH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NOI M D H Design Services www. mchdesianservices.com phone: (631) 298-2250 a-maih michael@ mchdesignservlces.com © DR~W~ BY: MH November 16, 2008 SC_~LE: 1/4" = SHEET NOI GENERAL NOTES CONSTRUCTION NOTES: FOUNDATION NOTES: FRAMING NOTES WIND FRAMING NOTES DECK AND COVERED PORCH NOTES: to g[rdar(s), PLUMBING NOTES HVAC SYSTEM NOTES ELECTRICAL NOTES: ALTHOUGH EVERY EFFORT HAS SEEN MADE IN PREPARING THFSE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALI DETAILS AND DIMENSIONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES. THESE DRAWINGS CONFORM TO GENERALLY ACCEPTED BUILDING PRACTICES, HOWEVER STATE AND LOCAL CODES VARY WIDELy. THE DESIGNER SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONS~UCT~ON SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THE PRINTED NAILING SCHEDULE ROOF FRAMING: WALL FRAMING: JOINT DESCRIPTION NAJL NNL QI~ SPACING NOTES FLOOR FRAMING: JOINT DESCRIPTION NAtL NAIL Q~' SPACING NOTES PER TOE JOIST TO 4-8d COMMON JOIST NAIL SILL, TOP pLATE DR GIRDER BRIDGING EACH TOE ROOF SHEATHING: NAIL NAIL JOINT DESCRIPTION QTY, SPACING CEILING SHEATHING: WALL SHEATHING: IOINT DESCRIPTION NAIL NAIL Q~ SPACING S~RUCTURAL 8d COMMON AS PERTABLE 3.~ PANELS WFCM - SBC 7116" OSB 3" O.C EDGE pLYWOOD 6d COMMON 6' O,C, FIELD GYPSUM 7" O C, EDGE WALLBOARD 5d COOLERS 10' O*C. FIELD FLOOR SHEATHING: NAIL NNL JOINT DESCRIPTION Q~. SPACING 1" OR LESB 8d COMMON 12" O C. FIELD STRUCTURAL PANELS 6" D.C. EDGE NOTES: THESE NOI~S ARE ONLY TO BE REFERRED TO IF MENTI~3 NED IN SCHEDULE NOTES ONLY, 1). Nailing requ]tement~ am based on Wall sheathir*g PLAN CONTENTS: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL BUILDING USE RESIDENT[AL DWELLING BUILDING HEIGHT (SEE pLANS) CLIMATIC & GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC ~EJkl FROST WIN'i'ER ICESISELD FLOOD SNOW SPEED DESIGN THERING LINE TERMITE DECAY DESIGN UNDERLAYMENT HAZARD~ ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: SHEATHING LOCATION N~IL SPACING NAIL SPACING AT IN I~RMEDIATE SEE NO3]ES: 1,3 AT PANEL EDGES SUPPORTS IN THE PANEL FIELD NOTES 8d COMMON ~ 6" O C §d COMMON ~ 6~ D.C. SEE NOTES: 1.3 8d COMMON ~ 6" O.C, 8d COMMGN ~ 12" O C SEE NOTES: 1 ( BOTH FIELDS) 8d COMMON ~ 4" O,C. 8d CGMMDN ~ 4' O.C NOI~; 2 FOR PANEL ~:]ELD NOTES THESE NOTES ARE ONLY TO BE REFERRED TO ~F MENTIONED IN BCHEDULE NOTES ONLY WALL SHEATHING REQUIREMENTS FOR WIND LOADS: BHEATHING LOCATION NAIL SPACING NAIL SPACING AT IN.RUED[ATE NOTES AT P,~N E L EDGES SUPPORTS IN THE PANEL FIELD 4' EDGE ZONE ~J COMMON ~ 6" D.C. SE~ NOTES: 1, 3 ( BOTH FIELDS NOTE~ THESE NOI~S ARE ONLY TO BE REFERRED TO IF MENTrONEO IN SCHEDULE NOTES ONLY NOTE: CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. tvl E H Design Services www, mchdesionservices.com 298-2250 ~-mail: micha el@mchdeslg nservJces,com DRAWN BY: MH November 16, 2008 SCALE: 1/4" = 1'-0" SHEET NOI