CERTIFICATE OF OCCUPANCY
No: 36014 Date: 10/18/2012
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 2025 Sigsbee Rd, Laurel,
SCTM #: 473889 Sec/Block/Lot: 144.-2-17
Subdivision: Filed Map No.
conforms substantially to the Application for Building Permit heretofore
8/23/2012 pursuant to which Building Permit No.
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
electric Solar Panel system on an existing one family dwelling as applied for.
Lot No.
filed in this officed dated
37538 dated 9/24/2012
The certificate is issued to
Magg, Thomas
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
37538 10/4/12
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 37538
Date: 9/24/2012
Permission is hereby granted to:
Magg, Thomas
67 Apache Dr
Manalapan, NJ 07726
To:
construct an electric Solar Panel system as applied for
At premises located at:
2025 Sigsbee Rd, Laurel
SCTM # 473889
Sec/Block/Lot # 144.-2-17
Pursuant to application dated
To expire on 312612014.
Fees:
8/23/2012
and approved by the Building Inspector.
SINGLE FAMILY DWELLING - ADDITION OR ALTERATION
CO - ADDITION TO DWELLING
Total:
$50.00
$50.OO
$100.00
/~X'~"~uildin~ '
Inspector
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF occUPANCY
This' application must be filled in by typewriter or ink and submitted to the Building Department with the following:
For new building or new use:
1. Final survey of property with accurate'location of all buildings, property lines, streets, and unuzual namra} or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3-. Approval of electrical installation from Board 0fFire Underwriters.
4. 'Sw. orn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead..
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance'from architect or engineer responsible for the building~
.6. Submit Planning Board Approval of completed site plan requirements.
For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "Pre-existing" land uses'.'
I. Accurate survey of proPerty showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly ¢0mpleted application and con. sent to inspect signed by the applicant. Ifa Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to thc applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00~
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of.Occupancy - $:25
4. Updated Certificate of Occupancy - $50.00
- 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $ l 5.00
(check one)
New Construction: Old or Pm-existing Building:
Location ofProperty.~ 2 o 2, ~ ! ~ ,'c~ ~ [~_p~. ~°o~
. House No.. ~7~~ ' Street
Owner or Owners of Property: ~ ~/~ ~'~
.. _ / ,4[
Suffolk County Tax Map No 1000, Section l ~ Block
Subdivision
3 75- 5%
Health Dept. Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $ 5~0. f
Hamlet
Filed Map.
Date of Permit. t~_ 2~- t 21. Applicant:
Underwriters Approval:
Final- Certificate: /
(check one)
~4t~pplicant Sign~atur~
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
Telephone (631 ) 765-1802
Fax (631) 765-9502
ro.qer, richert~,town.southold.ny, us
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Thomas Magg
Address: 2025 Sigsbee Rd City: Mattituck St: NY Zip: 11952
Building Permit #: 37538 Section: 144 Block: 2 Lot: 17
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: home owner DBA: License No:
SITE DETAILS
Office Use Only
Residential ~ Indoor ~ Basement ~ Service Only ~
Commerical Outdoor 1 st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 3 ph Hot Water GFCI Recpt Wall Fixtures ~ Smoke Detectors
Main Panel NC Condenser Single Recpt Recessed Fixtures ~ CO Detectors
Sub Panel NC Blower Range Recpt Fluorescent Fixture ~ Pumps
Transformer Appliances Dryer Recpt Emergency Fixtures~ Time Clocks
Disconnect Switches Twist Lock Exit Fixtures [~j Tvss
Other Equipment: PHOTOVOLTAIC SYSTEM to include, 15-Canadian Solar cs6p-230p panels with.
micro inverters, terminating at a 20a circuit breaker in main service panel
Notes:
Inspector Signature:
Date: Oct 4 2012
81-Cert Electrical Compliance Form.xls
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST
[ ] FOUNDATION 2ND
[ ] FRAMING/STRAPPING
[ ] FIREPLACE & CHIMNEY [
[ ] FIRE RESlSTANT CONSTRUCTION [
[ ] ELECTRICAL (ROUGH) [
[ ] ROUGH PLBG.
[ ] II~SiJLATION
[~]/~INAL $oL~,~ ~)~~
] FIRE SAFETY INSPECTION
] FIRE RESISTANT PENETRATION
] ELECTRICAL (FINAL)
REMARKS:
~ ~
DATE
f
TOWN OFSOUTHOLD
· BUiLDING'~DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork. net
Examined
Approved
Disapproved
% ,20
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check V/
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mailto: 2' Z5
Phone: ~3~-3/0-'33
Building Inspector
PPLICATION FOR BUILDING PERMIT
[ ........ ~ Date
~0\~l',', c,~ ,,~ ...... ~ ..... INSTRUCTIONS
a. This application MUST be completely filled in by ~pewriter or in i~ and submi~ed to the Building Inspector with 4
sets of plans, accurate plot pl~ to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Pe~it to the applicant. Such a pe~it
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in pa~ for any purpose what so ever until the Building Inspector
issues a Ce~ificate of Occupancy.
fi Eve~ building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
prope~ have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pe~it for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS ~BY MADE to the Building Depa~ment for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk Count, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises ~d in building for necessa~ inspections.
( cant orn~ if a co~oration)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises "'T- h o ~t 0. $ ~ fl. c[.o~
(A~'8~ the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No. 5e i ~-
Plumbers License No.
Electricians License No. Se 14:.
Other Trade's License No.
Location of land on which proposed work will be done:
House Number Street
Hamlet
County Tax Map No. 1000 Section
Subdivision
Block '~-
Filed Map No.
Lot
s~ate existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy ~; ~ c~! ~z ~ at ~' (. 7 I'~ o }a f'
b. Intended use and occupancy. C=o,. r,t -~
o
Nature of work (check which applicable): New Building
Repair Removal Demolition
Addition
Other Work
4. Estimated Cost ~ ("l ooo Fee
5. If dwelling, number of dwelling units
If garage, number of cars
Alteration
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of exi§ting structures, if any: Front %$ Rear
Height]'~- Number of Stories ~
Z~
Depth JrO
Dimensions of same structure with alterations or additions: Front ~ ¢
Depth 4- c~ Height ~ ~ Number of Stories
Rear
8. Dimensions of entire new construction: Front
Height Number of Stories
Rear Depth
9. Size of lot: Front Rear
10. Date of Purchase i / Z'or//I ~~0~' Name of Former Owner
11. Zone or use district in which premises are situated
Depth
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO If
13. Will lot be re-graded? YES__ NO V/' Will excess fill be removed from premises? YES
NO //'
14. Names of Owner of premises
Name of Architect
Name of Contractor
Address
Address
Address
7_0 Z~£;,qs~e~- ?oi. Phone No.
u,~ tt,'eve h,~ ~avO~Sr Phone No
Phone No.
z - t0- 3:3 5
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
NO /
16. Provide survey, to scale, with accurate foundation plan and distances to property lines. ~/o C,h~¢
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO V/
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY
~-ho ~t ¢ ~ ~ q ~ ~ being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signiffg contract) above named,
(S)He is the 0
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this ~ 20 /c~ '"//--'~
~,,~/,~dayof,/.,/_ ~-. , -~///~. ,',..~' pAiRiCiARiC,~~ ~,~/
N~tary Public No. 3~-4741154 S~gnature of ~pp~cant
0ualified in Nassau / Suffffk Co~li~
Commission Expires /~/~///~
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
Telephone (631) 76.5-1802
ro.qer, mdChert~,~w(ena.l's).JuCu~l~So(~l, n y. us
BU~ ~c
TOWN OF' SOUTHOLD
APPLICATION FOR ELECTRICAL INSPECTION
Company Name: 5¢ ( ~
'Name: ~(% o.~. ~: .N1¢ o~.
NO.:
Date:
No.: 73 a-2t0-~3~ ~
JOBSITE INFORMATION:
*Name:
*Address:
*Cross Street:
*Phone No.:
Pe~it No.: . ~ ~ ~ ~
Tax-Map .District: 1000 Section: ~ ~ 4 Block:
*BRIEF DESCRIPTION OF WORK (Please Print Clearly)
(*Indicates required information)
Lot:
· 'YES N~ YES / NO
(Please Ci.rcle All That Apply)
*Is job ready for inspection:
*Do-you need a Temp Certificate:
Rough In Final
Temp Information. (If. needed) ·
*Service'Size:.
~ .3...~ ~o0 ~.0 ~ ~oo ~..o .00 O~e.
·New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additienal Information: PAYMENT DUE WITH. APPLICATION
82~Request for Inspection Form
Condon Engineering, P.C.
Ne~ Yor~ State Licensed Profea~onal Engineem
17~, ~b~ Ro~d
~~, ~ Y~ 11~2
631-2~8-1986
Fax 631-2982651
September 20, 2012
Mr. Mike Verity
Building Department
Southold To~n Hall
53095 Route 25
P.O. Box 1179
Southold, New York 11971
Dear Mr. Verity:
As requested, I made a visit to the 2025 Sigsbee Road residence in MatlJtuck, New York on
September 18, 2012 to evaluate the existing roof struc~re where the new solar panels are
proposed.
Based on the specifications the panels and the rack mounting system will produce a gravity load
of appmximak~ 2.8 pounds per squa,-e foot. Based on this load it is my professional opinion
based on my familiarity with the building that the existing roof will be able to supfloft the weight of
the solar panel system as well as the Code presc~bed 20 pounds per square foot snow load.
If you have any questions please call me at 298-1986.
Yours truly,
SEP 2 1 2012
BLDG. DEPi.
TOWN OF SOUIHOLD
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
Telephone (631 ) 765-1802
Fax (631) 765-9502
October 15, 2012
BUILDING DEPARTMENT
TOWN OF SOUTI-IOLD
Thomas Magg
67 Apache Dr
Manalapan, NJ 07726
Re: 2025 Sigsbee Rd, Laurel
TO WHOM IT MAY CONCERN:
The Following Items Are Needed To Complete Your Certificate of Occupancy:
NOTE: An Architect or Engineer needs to certify that the panels were fastened to the roof according
to NYS Building Code conforming with wind load requirements.
A fee of $50.00.
__ Final Health Department Approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
__ Trustees Certificate of Compliance. (Town Trustees # 765-1892)
Final Planning Board Approval. (Planning # 765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
BUILDING PERMIT: 37538 - Solar Panels
TOWN OF SOUTHOLD PROPERTY RECORD CARD /,~/..~"-~
OWNER STREEI' "~_~'~ VILLAGE DIST' SUB. LOT ~'~
RES. ~ S~S. ~ VL. FARM COMM. CB. MISC. Mkt. Value '-
~N D IMP. TOTAL DATE REMARKS
N~ NOR~L BELOW ABOVE
F~M Acre Value Per Value
Acre .,
Tillable 1
Tillable 2
Zillable 3
Woodland
Swampland FRONTAGE ON WATER
Brushland FRONTAGE ON ROAD
~Ouse Plot DEPTH /
~ ~ ~ ~ ~ BULKH~D
Total DOCK
M. Bldg.
Extension
Extension
E~nsion
Porch
Porch
Breezeway
Garage
Patio
O.B.
Total
Foundation Bath /
COLOR
,"Basement
/ Ext. Walls
/ Fire Place
Type Roof
/?J.j Recreation Roorr
Dormer
Driveway
Floors
Interior Finish
Heat
Rooms 1st Floor
Rooms 2nd Floor
Dinette
K.
LR.
DR.
BR.
FIN. B.
Co? '
Thomas Magg
2025 Sigsbee Road
Mattituck, NY 11952
August 20, 2012
Town of Southold
Building Department
Town Hall
Southold, NY 11971
Re: Solar Panels 2025 Sigsbee Road
Dear Building Department:
Please find the following attachments to my application for solar
1) Solar Mounting Plans
ELECTRICAL
INSPECTION REQUIRE
APPROVED AS NOTED
~WlNO IN~Y~ON~~
2) Solar Electdc Drawings
3) Stamped Engineering Report by New York Certified Professional~~PANCY OR
4) Equipment Datasheets for All Equipment Being Installed
5) PVWattsCalculations USE iSUNLAWFUL
I have also included the following description and details to supplement t~i~ atta~rfients:'- ~- -
1) Overall Description of the System L,,?~ t, ~ .
The Solar Photovoltaic System to be installed consists of an Array of 15 AC Modules. Each
AC module consists of a Canadian Solar CS6P-230P 230 watt solar panel coupled with an
UL listed Enphase M215 Micro-inverter. Each Enphase M215 Micro-inverter is connected to
a factory made AC Trunk Cable consisting of 12-3 with ground outdoor rated cable. The
connection is via a waterproof connector that can only be disconnected with an Enphase
disconnect tool. The AC Trunk Cable is then routed through the gable and connects in a
junction box to 12-3 NM Romex wire that is routed from the junction box to the main
electrical panel. The wire is supported by cable staples every 3 feet along the rafters when
running parallel and via %" holes more than 1.5" from edge of rafters when running
perpendicular to the rafters. The 12-3 NM Romex terminates in the main electrical panel via
a 20 Amp 2 pole circuit breaker (240 AC), whereas the neutral and ground terminate in the
grounding buss bar. The system is further grounded by a continuous bare ~ conductor
which connects to each of the modules and rack and then connects to a #6 shielded
conductor which is routed to the main electrical panel and the terminates in the grounding
buss bar. As needed irreversible cdmps will be used for any connection with the ~6
conductor.
The total DC Rating of the system is 3.45 kW. With a derating factor of .858 as calculated
by PVWatts results in an AC Rating of 2.96 kW with a yeady production of 4031 kWh.
Please see attached specifications for. 1) Canadian Solar CS6P-230P Solar Panel, 2)
Enphase M215 Micro-inverter, and 3) Enphase Engage AC Trunk Cable.
2) Electrical Calculations for conductor ampacity: Each NC Micro-inverter generates a
nominal 0.8958A. For 15 micro-inverters this is a total of 13.43A.
NEC (Article 210.19, FPN 4), recommends that branch circuit conductors be sized for a
maximum of 3% VRise. VRise in this circuit is a sum of the Enphase Engage Cable, the AC
Branch Circuit to the dedicated circuit breaker, the connection at the AC junction box and the
circuit breaker at the main load center. The VRise per the factory Enphase Engage Cable
for 15 microinverters in a 1 .Om portrait cable run is 1.52 volts or 0.63%. VRise for the AC
branch circuit: VRise = (amps/inverter * # of inverters) * (resistance / foot) * (2 Way Wire
Length). Using 12-3 solid, and NEC chapter 9 table 8, the resistance of the conductor is
.00201 ohm#cot. The wire length is 73 feet. Therefore, VRise = (0.8958A * 15) * (.00201) *
(2 * 73) = 3.94 volts. VRise is % is 3.94 volts / 240 volts = 1.643%. The combined VRise %
= 0.63% + 1.643% = 2.273%. This leaves 0.727%. The OCPD and connection is the AC
junction box would be negligible and far less than 0.727%, which keeps the VRise within
NEC requirements.
I can be reached at tma(~(~..ma(~(~net.com or 732-310-3388 (mobile) or 208-694-5069 (fax)
if you require any further details.
Thank You,
Sincerely,
Thomas Magg
2025 Sigsbee Road - Solar Panel Plan
Lat 40,979
Lonl~ -72.534
Pitch 22.3 deg
Orient 163 deg
Proposed Location of
Solar Panels on House
Flange Attachment
CLICKSYS Beam
Solar Panel
CSP*230P 64.5# x 38.7" x 1.57"
Existing Skylight
196"
203.5"
216"
I 2 I $ 4, '
Electrical Line Diagram - 2025 Sigsbee
Road, Mattituck, NY
Existing #6 AWG GEC /
Existing Grounding
Electrode
' I 2 I 3 I' · I
Peak Soia? LLC
PROPRIETARY
SolarMount I-Series, 2.5 Beam Engineering Report, Page 1 of 2
90 mob Wind Chart I Max Span (inches)
Ground Snow Point Loads (pounds): Up/Down/Side
Module Size 0 20 30 40
52" x 35"I 76 67 57 51
~ 315/355~ 73 2711392~ 123 231/385~ 144 205~ 423/163
65"
x
40"
63 56 51 45
319/365/75 284/410/129 259/430~ 161 2291473/182
50 44 41 37
3001344/70 267/386/121 245/414/155 224/4611177
1t0 mph Wind Chart
Ground Snow
Module Size 0 20 30 40
64 62 57 51
399/423~ 61 386/437/115 354/455/144 314/4521163
53 51 48 45
419/434/63 397/449/118 372/479/152 3511509/182
42 41 38 36
386/409/59 373/422/111 350/450/143 33114771172
77" x 51"
52" x 35"
65" x 40"
77" x 51"
120 mph Wind Chart
Ground Snow
Module Size 0 20 30 40
52" x 35"
65" x 40"
77" x 61"
150 mph Wind Chart
Ground Snow
Module Size 0 20 30 40
52" x 35"
65" x 40"i
59 59 55 51
4421458~ 56 437~ 463/108 413/490/140 375/495/163
49 48 46 43
4541479/58 449/475/11 t 424~ 500/144 40315301174
39 38 36 34
427/440/55 423/447/105 399/474/136 379/4991164
77" x 51"
48 48 48 46
566/550/46 569/559/89 565/566/122 544/588/149
40 40 39 38
5811574147 581/574/91 581/581 / 125 559~ 504/153
31 31 31 30
547/540/44 547/540186 5471547/118 525/569/t 44
upmm
-]- module
/ module S~de
//module
[Know¥our Iimit~! 1
Check atlachm~nt
load limits.
· Long edge of module must be perpendicular to the beam ~,: .,
· The installer must compb/wflh the resp~sibi#bes and instructions described in the Install mmtual /,~ ~...- ·
SolarMount I-Series, Beam Engineering Report, Page 2 of 2
2.S
En~ineerin;i Variable~
Description Variable Value Units
Building Height h 30 ft
Roof Pitch 0-45 degrees
Wind Exposure Category C
Importance Factor ! 1
EffecFrve Wind Ares 50+ f12
Topographic Factor Kzt 1
Roof Zone 1 (use 1/2 span for zones 2 and 3)
Design Wind Loads
Basic Wind Speed (mph) I 9_.~0 110 12~0
Max Design Wind Load, Pnet; Uplift (pst} I -19.2 -28.7 -34.2
Max Design Wind Load, Pnet; Downforce (psf) 17.5 26.0 31.1
-53.3
48.4
Deadt Snow; and Eartheluake Loads
Dead Load; m/n/max 2 / 3.5 psf
Earthquake Load 2.8 psf
Ground Snow Load1 Pg, (pounds/fi2.) ~ _0 2._~0
Max Sloped roof snow load (psf) I 0.0 20.0
Max Distance between splices (inches, feet) 653~ 54 336, 28
3_.Q0 4...~0
25.2 33.6
245~ 20 193~ 16
Distributed Loads for 65" x 40" module, pounds/inch
lemaller modules -20%I lar~er modules
Ground Snow Load (psf)
Wind Load (mph) 0 20 30 40
Upli~
J- module
.L module Side
.1_: perpendicular/normal
II: parallel
' 9_.~ 4.06 4.06 4.06 4.06
4.65 5.87 6.75 8.37
0.95 1.84 2.53 3.22
110 6.21 6.21 6.21 6.21
6.57 7.02 7.98 8.94
0.95 1.84 2.53 3.22
120 7.44 7.44 7.44 7.44
7.71 7.88 8.83 9.79
0.95 1.84 2.53 3.22
150 11.77 11.77 11.77 11.77
11.63 11.63 11.77 12.73
0.95 1.84 2.53 3.22
For installations that do not comply with the limitations on page 1, refer to www.unirac,com
for an engineering design guide to manually calculate loads or contact your distributor,
The design is based on and in compliance with the following codes/standards:
1. 2003 International Buildinq Code, by International Cede Council, Inc., 2003.
2. 2006 International Build/hR Code, by International Code Council, Inc., 2006.
3. Aluminum Des/an Manuah Specifications and Guidelines for Aluminum Structures. by The Aluminum
Association, Washington, D.C., 2005.
4. 2007 California Build/hR Code (CBC),
Cede Council, Inc., 2006.
based on the 2006 International Building Code, by
James A. Marx, Jr.
Professional Engineer
10 High Mountain Road
Ringwood, NJ 07456
cmail: jamlight~vcrizon.net
Thc installer is r~spunsibl¢ for datermining thc
loading and that ~11 the listmJ r~quiremcnts are met
when applying thc charts. Conditions outside thc
rcquircnmnts and limitations may b~ l'casiblc, but
shall bc designed with Unirac consultation.
Unirac -.~OLARMOUNTi Configurator Results
http://unirac.eom/eonfigurators/estimator_iseries/?module=clicksys&tas...
SOLARMOUNTiTM Configurator Results
paint L~ad~
Point Load, Down: 388 pounds
Point Load, Up 327 pounds
Point Load, SKle; 111 pounds
· Base par[ numbers ace shown; please see 1he U NIRAC Master p~tce List ladfl for corn p}ele number and pncmg
For installations that do not comply with the limitations below, please refer to the SolarMount confiqurator.
[tim stamped engineerint3 reports fi~r other states, please r~fer to our SolarMount-I Technical sw~)ort l)aae.
1 of 3 8/22/2012 3:50 PM
CanadianSolar
Key Features
· 6 years product warranty (materials and workmanship);
25 years modulepower output warranty
· Industry leading plus only power tolerance: +5W (+2.1%)
· Strong framed module, passing mechanical load
test of5400Pa towithstand heavier snow load
· The 1st manufacturer in PV industry certified for
ISO:TS16949 (The automotive quality management
system) in module production since 2003
· ISO17025 qualified manufacturer owned testing lab,
fully complying to IEC, TUV, UL testing standards
On-grid Module
CS6P is a robust solar module with 60 solar
cells. These modules can be used for on-grid
solar applications. Our meticulous design and
production techniques ensurea high-yield,
long-term performance forevery module
produced. Our rigorousquality control and
in-house testing facilitiesguarantee Canadian
Solar's modules meetthe highest quality
standards possible.
Applications
· On-grid residential roof-tops
· On-grid commercial/industrial roof-tops
· Solar power stations
· Other on-grid applications
Quality Certificates
· IEC 61215, IEC61730, UL1703, CEC Listed,CE
· ISO9001: 2008: Standardsfor quality
management systems
· ISO/TS16949:2009: Theautomotive quality
management system
· QC080000 HSPM:The Certificationfor
Hazardous Substances Regulations
www.canadiansolar.com
CS6P-210/21 512201225123012351240P
Electrical Data
C86P-210F CS~P.215P 28eP~220P CS~P,22gF CS6P~230P
Nominal Maximum Powerat STC (Pmax) 210W 215W 220W 225W 230W 235W 240W
Optimum Operating Voltage (Vrnp) 29V 29V 29.2V 29.4V 29.6V 29.8V 29.9V
Optimum Operating Current(Imp) 7.25A 7.4A 7.53A 7.65A 7.78A 7.9A 8.03A
Open Circuit Voltage (Voc) 36.4V 36.5V 36.6V 36.7V 36.8V 36.9V 37V
Short Circuit Current {Isc) 7.89A 8.01A 8.09A 8.t9A 8.34A 8.46A 8.59A
__~Operating Temperature -40~C~+ 85~D
Maximum System Voltage 1,000V (IEC) 1600V(UL)
Maximum Series Fuse Rating 15A
Power Tolerance +SW
Pmax -0.43%?C
Voc -0.34
Temperature Coefficient
Isc 0.065
NOCT 45"(~
Under Standard Test Conditions (STC) of irradiance of 1000w/m=, spectrum AM 1.5 and cell temperature of 25'C
Mechanical Data
Cell Type Poly-crystalline
Cell Arrangement 60 (6 x 10)
Dimensions 1638 x 982x 40mm (64.5x 38.7 xl.57in)
Weight 20kg (44.1 lbs)
Front Cover Tempered glass
Frame Material Anodized aluminium alloy
Standard Packaging (Modules per Pallet) 20pcs
Engineering Drawings
*Specifications included in this datasheet are subjec~ to changewithout prior notice.
I-V Curves (CS6P-240P
About Canadian Solar
Canadian Solar is a vertically-integrated manufacturer
of ingots, wafers, cells, solar rnodulesand custom-
designed solar powerapplications. Canadian Solar
was founded in Canada in 2001 and was successfully
listed on NASDAQExchange (symbol: CSIQ)In
November 2006.
By the end of 2008, Canadian Solar has a module capacity ofover
600MW. Withrevenue of 709.2 million dollars in2008, a 134%
growth in revenueover 2007, CanadianSolar has becorneone of
the fastest-growing companiesin the solarlndustry.
lei
ENPHASE
MICROINVERTER
M215
enphase
leis.
Tl~e Enphase Energy Microinverter System improves energy I~arvest,
increases reliability, and dramatically simplifies design, installation and
management of solar power systems. The Enphase System includes the
microinverter, the Envoy Communications Gateway, and Enlighten,
Enphase's monitoring and analysis software.
PRODUCTIVE
I- Maximum energy production
- Resilient to dust, debris and shading
- Performance monitoring per module
RELIABLE
I - System availability greater than 99.8%
- No single point of system failure
SMART
I- Quick & simple design, installation and management
24/7 monitoring and analysis
SAFE
I- Low voltage DC
Reduced fire risk
C~S
MICROINVERTER TECHNICAL DATA
Input Data (DC)
Recommended maximum input power (STC)
Maximum input DC voltage
Peak power tracking range
Operating range
Min./Max. start voltage
Max. DC short circuit current
Max. input current
Output Data (AC)
Maximum output power
Nominal output current
Nominal voltage/range
Extended voltage/range
Nominal frequency/range
Extended frequency/range
Power factor
Maximum units per 20A branch circuit
Maximum output fault current
Efficiency
M215-60-2LL-S22/S23
M215~O0-2LL-S22-NA/S23-NA (Ontario)
260W
45V
22V- 36V
16V 36V
26.4V/45V
15A
10.5A
@208 Va¢ @240 Vac
215W 215W
1.0 A* 0.9 A*
208V/183V-229V 240W211V-264V
208V/179V-232V 240W206V-269V
60.0/59.3-60.5 60,0/59.3460.5
>0.95 >0~95
25 (three phase) 17 (single phase)
1.05 Arms, over 3 cycles; 25.2 Apeak, 1.74ms duration
CEC weighted efficiency
Peak inverter efficiency
Static MPPT efficiency (weighted, reference EN S0530)
Dynamic MPPT efficiency (fast irradiation changes, reference EN S0530)
Night time power consumption
Mechanical Data
Ambient temperature range
Operating temperature range (internal)
Dimensions (WxHxD)
Weight
Cooling
Enclosure environmental rating
Features
Compatibility
Communication
Warranty
Compliance
96.0%
96.3%
99.8%
99.9%
46mW
-40°C to +65°C
-40°C to +85°C
17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0")*
1.6 kg (3.S lbs)
Natural convection - no fans
Outdoor - NEMA 6
Pairs with most 60-cell PV modules
Power line
2S-year limited warranty
UL1741/IEEE1547, FCC Part 15 Class B
CAN/CSA-C22.2 NO. 0-M91,0.4 04, and 107.1-01
*Arms at nominal voltage
*without mounting bracket
Enphase Energy, Inc.
201 1st Street, Petaluma, CA 94952
877 797 4743 www.enphase corn
05/17/201
~j~ Printed on 100 percent recycled pape~
The Engage Cable is a continuous length
of 12AWG cable with pre-installed
connectors for Enphase Microinverters
to plug into. The cable is handled
like standard outdoor-rated electrical
wire, allowing it to be cut, spliced and
extended as needed.
The Engage Accessories complement the
Engage Cable and give it the ability to
adapt to any installation.
ENGAGE
SYSTEM
FAST
FLEXIBLE
SAFE
I- Quick installation
- Large branch capacity
- Simple design
No additional cables
I- No high voltage DC
- Reduced fire risk
C US
" CABLING ACCESSORIES - DETAILS and SPECIFICATIONS
Voltage
240VAC, 4 conductors
240VAC, 4 conductors
208VAC, 5 conductors
208VAC, 5 conductors
Connector Spacing Accommodates PV module orientation
1.025 meter (40") Portrait
1.7 meter (67") Landscape
1.025 meter (40") Portrait
1.7 meter (67") Landscape
Description
Cable temperature rating
Cable insulator rating
UV exposure rating
Conductor gauge
Compliance
Rating
90°C (194°F) wet/dry
THWN-2
UL 746 C, F1
12AWG
UL1741; CAN/CSA C22.2
Nos. 0, 21, 42, 65, ~53,
182.1,182.2, and 182.3; IEC
60529 IP67
Model Number Orientation # Connectors Approx weight
ET10-240-40 Portrait 40 40 lbs
ET17 240-40 Landscape 40 45 lbs
ET10-208-30 Portrait 30 30 lbs
ET17-208-30 Landscape 30 35 lbs
*additional lengths available through Enphase authorized
distributors.
Branch Terminator
One terminator needed per branch circuit
ET-TERM-10 (quantity 10)
Watertight sealing cap
One needed to cover each unused
connector on the cabling
ET-SEAL-10 (quantity 10)
Disconnect tool
Plan to use at least one per installation
ET DISC-05 (quantity 5)
Cable clip
Many needed to fasten cabling to the
racking or to secure looped cabling.
ET-CLIP-100 (quantity 100)
142-00013 Rev 01
Enphase Energy, Inc.
201 1st Street
Petaluma, CA 94952
Phone: 877-7974743
Fax: 707-763-0784
PVWatt$.v.2: AC Energy and Cost Savings http://rredc.nrel.gov/solar/caleulators/PVWATTS/version2/pvwattsv2.egi
AC Energy
&
Cost Savings
Station Identification Results
Cell ID: 10271369 Solar AC Energy
State: INew York Month Radiation Energy Value
(kWh/m2/day)(kWh) ($)
Latitude: 141'1 °N 1 I 2.34 [ 209'I 29.12
Longitude: 172.7 ° W
2 [ 3.13 I 256 I 35.67
PV System Specifications 3 [ 4.29 I 379 [ 52.81
DC to AC Derate Factor: 10.828 5 [ 5.32 I 443 I 61.72
AC Rating: 12.86kW 6 [ 5.78 ] 456 [ 63.53
Array Type: IFixed Tilt 7 [ 5.33 I 428 F 59.63
Energy Specifications 10I 3.64 '[ 307I 42.77
[Cost of Electricity: [13.9 e/kWh
12 [ 2.19 [ 189 [ 26.33
t -
~ Output Results as Text [
(Gridded data is monthly, hourly output not available.) Saving Text l¥om a Browser
[ Run PVWATI'S v 2 for another location I Run PVWATTS v 1
['lease send questions and comments to ~Vebn,aste,
l?scla me, a,,~ cops~r,ght
1 of 1 8/22/2012 5:26 PM
PVWATTS v.I - Derate Factor Calculation
http://rredc.nrel .gov/solar/calculatom/PV WATI'S/derate.cgi
If the default overall DC to AC derate factor of 0.77 is not appropriate for your PV system,
you may use this calculator to determine a new value by changing one or more of the
component derate factors in the table and clicking the "Calculate Derate Factor" button. You
may enter values within the ranges shown in the table. Values outside the ranges are reset to
to the default values by the derate calculator. The new overall DC to AC derate factor may
be hand entered, or copied and pasted, into the "DC to AC Derate Factor" field on the PV
Systems Specifications section of the PVWATTS input form. Click on HELP below the
table for information about DC to AC derate factors.
Calculator for Overall DC to AC Derate Factor
Component Derate Factors Component
Derate Values
I PV module nameplate DC rating 0.98
[ Inverter and Transformer .96
I Mismatch 0,98
I Diodes and connections 0.995
I DC wiring 0,98
I AC wiring 0.99
] Soiling 0.95
I System availability 0.98
I Shading 1
I Sun-tracking 1
1
I Age
Range of
Acceptable Values
0.80- 1.05
0.88 - 0.98
0.97 - 0.995
0.99 - 0.997
0.97 - 0.99
0.98 - 0.993
0.30 - 0.995
0.00 - 0.995
0.00- 1.00
0.95- 1.00
0.70- 1.00
Overall DC to AC derate factor 0.828
Calculate Derate Factor
1 of I 8/22/2012 5:24 PM