Loading...
HomeMy WebLinkAbout37471-ZSubject Location Existing Location Coverage (-75dBm) Map: Existing Coverage Including LI13-058A Site ID: LI13-058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 T..Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/18/2011 Subject Location Existing Location Coverage (-7$dBm) Map: "Gap Map" coverage without LI13-058A Site ID: LI13.058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 ..Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/18/2011 Subject Location Existing Location Coverage (-85dBm) Map: Existing Coverage Including LI13-058A Site ID: LI13-058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 ,Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/18/2011 · Subject Location · Existing Location ~ Coverage (-85dBm) Map: "Gap Map" coverage without LI13-058A Site ID: LI13-058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 q:..Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/18/2011 Subject Location Existing Location Coverage (-95dBm) Map: Existing coverage including LI13-058A Site ID: LI13-058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 N..Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/1812011 · Subject Location · Existing Location Coverage (-95dBm) Map: "Gap Map" coverage without LII3-058A Site ID: LI13-058A Site Name: Southold Substation Site Address: Main Rd, Southold NY 11944 ..Mobile Prepared by: Udaya Malikarjunappa RF Engineer for T-Mobile Map Date: 07/18/2011 ~1-'~ SITE PLAN SCALE: lrr=lO0' 0 / / I / MAiN ROAD 703 64450' O' 50' 100' WILLIAM K COLLINS, AIA A R C H I T E C T S, L LP W~C ~ NO. I0-8705 Northeast LLC 80UTHOLD SUB~rATIOIV M^IN ~OAD SOUTHOLD, NY l 179 1115058,4 COLLOCATION UTIUTY POLE FULL SITE PLAN NUMBER A-la i WILLIAM F, COLLINS, AIA 3500 SUNRISE HIGHWAY GREAT RIVER NY 11739  [50UTHOLD 5UBSTA T/ON/MAIN ~OAD, 50UTHOLD. NY 11 ~71 ' ; Mobile Mo~hea:~ EEC PAUL 3. TURN SUGmRGHTO~O SUNRISEH~ I I ~o A / 3/ U~.~RNSUG~RIGHTONTOCR~KE~/EMORICHES~RH~DRD~' DA~ J I / ~ SOUTHO~, NY 11791 ~ : I E~ GROUN~NG SCHE~.C & D~AIH 04,20,18 8 09/03~10 ~ APPRO~D ~ NOrD J TITLE 5HE~ J RE, NIELSEN, HUBER AND COUGHLI~ATE ~ DISAPPROVED/R~S[ k T-- J 8 L i SEE 1/A-lo FOR FULL SITE PLAN r SURVEY DISCLAIMER; MARKOUT REOUIRED - UNDERGROUND FACILITIES AND/OR COUNTERPOISE IN AREA HIGH VOLTAGE AREA EXISTING B4'-O" HIGH WOOD UTILI~( POLE TO REMAIN / o\ \ 1/A-2~F~OR ADDITIONAL INFORMATION.) ~ ,~ SURVEY DISCLAIMS;R; ANY PROPER~I' OR EASEMENT LINE MARKER THAT IS DISTURBED AS A RESULT OF THIS PROJECT SHALL BE REESTABLISHED IN PLACE BY A PROFESSIONAL LAND SURVEYOR TO ACCURATELY DELINEATE LIPA PROPERTY OR EASEMENT LINES. NQT~; DRAWINGS DEPICT THE ~NSTALLAT~0N OF NEW ANTENNAS, CABLING ETD, THAT ARE MOUNTED TO NEW STEEL UTILITY POLE A NEW STEEL POLE, ANTENNA MOUNT ASSEMBLY, AND REINFORCED CONCRETE FOUNDATION TO BE DESIGNED BY A NEW YORK STATE LICENSED PROFESSIONAL ENGINEER. SIGNED AND SEALED DOCUMENTATION FOR THIS WORK SHALL BE FILED SEPARATELY AND CONCURRENTLY WITH THESE DOCUMENTS. ALL SUCH WORK SHALL BE PERFORMED BY OTHERS IENVIRONMENTAL REVIEW & DISCLAIMER: PRIOR TO STARTING CONSTRUCTION. TH~S PROdECT MUST BE REVIEWED BY QUALIFIED PERSONNEL TO VERIFY THAT THIS PROJECT IS COMPLIANT WITH ALL FEDERAL. STATE AND LOCAL ENVIRONMENTAL. WETLAND AND E~RED SPECIES REGULATIONS GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH PROVISIONS OF LOCAL, STATE, AND FEDERAL. LAWS, ORDINANCES. AND REGULATIONS WHEREVER APPLICABLE 2 EACH CONTRACTOR SHALL BE HELD TO HAVE VISITED THE SITE AND TO HAVE VERIFIED ALL EXISTINC CONDITIONS PRIOR TO SUBMISSION OF BID 5. IN ALL CASES, DRAWINGS SHALL NOT BE SCALED FOR INFORMATION. FIGURED DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. 4 CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND JOB CONDITIONS, AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, CONFLICTS, AND/OR OMISSIONS WHICH WOULD INTERFERE WITH THE SATISFACTORY COMPLETION OF THE WORK. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL RESPONSIBILITY AND LIABILI~ ARISING THEREFROM 5. ALL ITEMS OF WORK IDENTIFIED ON THE DRAWINGS BY NAME, NOTE, OR MATERIAL DESIGNATION ARE NEW, UNLESS OTHERWISE NOTED. 6. ALL NEW MATERALS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS LATEST PRINTEO SPECIFICATIONS. AND WITH ALL APPLICABLE CODE REQUIREMENTS 7. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH BEST STANDARD TRADE PRACTICES. EACH TRADE SHALL COOPERATE WITH OTHER TRADES TO FACILITATE JOB SCHEDULING AND COMPLETION. 8. PROPRIETARY NAMES IDENTIFYING ITEMS OF WORK ARE USED TO DESIGNATE THE STANDARD OF CONSTRUCTION. ITEMS OF EQUAL QUALITY MAY BE SUBMITTED FOR THE ARCHITECTS RE%IBW AND APPROVAL. g- EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ADJOINING REMAINING AREAS AS A RESULT OF HIS WORK, AND SHALL REPAIR DAMAGED SURFACES TO THEIR PRE-EXISTING CONOITIONS OR AS MAY BE REOUIRED TO COMPLETE THE ENTIRE SCOPE OF THE WORK 10. ALTERATIONS TO EXISTING WORK SHALL BE PATCHED AND FINISHED, AS NECESSARY, TO MATCH EXISTING CONTIGUOUS SURFACES OR NEW FINISHES SHOWN. 11. AT THE COMPLETION OF EACH WORKDAY, EACH TRADE SHALL BE RESPONSIBLE FOR CLEANING UP THEIR WORK. RUBBISH REMOVAL SHALL BE DONE IN A DUST INHIBITIVE FASHION, AND THE JOB SITE SHALL BE FREE OF ALL DEBRIS AND BROOM CLEAN UPON COMPLETION. 12. CLEAN ALL FLOORS. WALLS. DOORS. MISC.. GLASS. E~C. LEAVING JOB FREE OF DUST AND DEBRIS. PRIOR TO PROJECT COMPLETION. 13. EXISTING EQUIPMENT AND MATERIALS TO BE REMOVED, WHICH ARE NOT REOUIRED TO BE RELOCATED OR RETAINED BY THE OWNER. SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND BE REMOVED FROM THE PREMISES. 14. INDICATIONS OF WORK TO BE REMOVED ARE GENERAL ONLY, AND ARE NOT INTENDED TO SHOW ALL ITEMS WHICH MAY REQUIRE REMOVAL. SUCH ITEMS SH~q_L BE REMOVED, RELOCATED, AND/OR REINSTALLED, AS REQUIRED FOR INSTALLATION OF NEW WORK. 15, THESE DOCUMENTS DO NOT AUTHORIZE DETERMINING THE PRESENCE, NOR THE REMOVAL OF ASBESTOS OR OTHER HAZARDOUS MATEREAJ_S. IF DURING THE COURSE OF THE PROJECT, ASBESTOS OR OTHER HAZARDOUS MATERIAL CONTAMINATION IS SUSPECTED. THE CONTRACTOR SHALL NOTIFY THE CARRIER'S PROJECT MANAGER WITHIN 24 HOURS, CONTRACTOR SHALL SUSPEND WORK IN THE AFFECTED AREA UNTIL SUCH A TIME THAT SAID AREA IS CERTIFIED CONTAMINATION-FREE. IN THE INTERIM, THE CONTRACTOR SHALL ENDEAVOR TO RESCHEDULE WORK TO AREAS UNAFFECTED BY SUSPECTED CONTAMINATION IN ORDER TO MINIMIZE DELAY ID THE PROJECT SCHEDULE. 16. ALL MECHANICAL AND ELECTRICAL WORK SHALL BE IN FULL CONFORMANCE WITH N.Y.S. UNIFORM FIRE PREVENTION AND BUILDING CODE. AND ALL OTHER APPLICABLE CODES AND REGULATIONS. 17. ELECTRICAL WORK SHALL BE INSTALLED BY AN ELECTRICIAN LICENSED IN SUFFOLK COUNTY IN ACCORDANCE WITH NEW YORK STATE AND NATIONAL ELECTRICAL CODES. A NEW YORK BOARD OF PINE UNDERWRITER'S CERTIFICATE SHALL BE OBTAINED FOR ALL ELECTRICAL WORK, AND SUPPLIED TO THE OWNER AND ARCHITECT. lB. PROVIOE ANY AND ALL TREATED WOOD BLOCKING/RACKING OR 14 DA. DALV. FLAT STOCK BACKING AS REQUIRED ED ENSURE PROPER AND ADEQUATE SUPPORT (IN COMPLIANCE WITH NEW YORK STATE BUILUING CODE MINIMUM LOADING REOUIREMENTS WHERE APPLICABLE) OF VARIOUS ITEMS INCLUDING, BUT NOT NECESSARILY LIMITED TO, HANDRAILS, SHELVING. CABLE TRAYS, CONDUITS, EEC 19 ADA COMPLIANCE: THE FACILITY IS A NORMALLY UNOCCUPIED MOBILE RADIO FACILITY. GENERAL SITE NOTES: I. ALL SITE WORK TO CONFORM TO THE LATEST TOWN OF SOUTHOLD PLANNING BOARD SPECS. AND STUB. 2. 'UEWATER' ALL TRENCHES AB REQUIRED DURING INSTALLATION OF ALL FOOTING AND FOUNDATION TO ENSURE PROPER DEPTH AND STRUCTURAL INTEGRITY OF CONCRETE. 3~ THE DEVELOPER SHALL COMPLY WITH APPROVED WORKING DRAWINGS AND REQUIREMENT SHEETS NO DEVIATION WILL BE PERMITTED EXCEPT BY WRITTEN APPROVAL OF THE TOWN GE SOUTHOLD PLANNING BOARD. 4. COMPACTION UNDER STRUCTURES, BUILDING SLABS, STEPS, PAVEMENTS AND WALK WAYS SHALL BE 95% MAXIMUM DRY OBNSITY, ABTM D 1557. COMPACTION UNDER LAWNS OR IN UNPAVED AREAS, 85% MAXIMUM DRY DENSITY, ABTM D 1557. B* ALL ELECTRIC AND TELEPHONE SERVICES SHALL BE INSTALLED UNDERGROUND. 6, ELECTRICAL CONTRACTOR TO TONE PATH OF EXISTING CABLE AND PROVIDE MARK-OUTS. HAND EXCAVATE NEAR ANY UNDERGROUND PIPES, UDUTIES, OR STRUCTURES. 7. CONTRACTOR SHALL CONTACT LOCAL UTILITY COMPANIES AND "DIG-SAFE" OR OTHER AUTHORIZED AND LEGALLY AND COMMERCIALLY ACCEPTABLE UTILITY LOCATOR SERVICE IN ORDER TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES WITHIN AREAS OF WORK PROVIDE ALL NECESSARY MEANS OF PROTECTION OF SAID EXISTING UTILITIES AS REQUIRED TO ACCOMMODATE NBW WORK. COORDINATE ALL REQUIRED RELOCATION WORK WITH THE AFFECTED UTILITY PROVIDER. B. ALL WASTE MATERIAL INCLUDING RUBBISH, STUMPS, DEBRIS, ETD, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND BE REMOVED FROM THE SITE. §~ CONTRACTOR TO MINIMIZE THE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION, EROSION CONTROL MEASURES, iF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMEN! CONTROL. 10. ALL CONCRETE USE0 FOR ON-SITB CONSTRUCTION SHALL BE AIR ENTRAINED, MINIMUM 4,000 PSi AT 2B DAYS 11 IF EXISTING DRAVEL BEDDING IS REMOVED, STOCKPILE, AND REBPREAD AS REQUIRED TO ACCOMMODATE NEW WORK RFRTORF I ANDgCAPE FI!TEN FABRIC AS WELL PRO\FIDE ADDITIONAL k4~TFRIA[~ AS REODIRFD l~ l~O~ NO. 10-8705 T-..Mobile- IXiorth~t LLC SUITE D-205 SI"I'E Ih~OI~k~lA'IlON ~IN ROAD SOUTHOLD, NY 11791 LII3058A DI~IGN TYPE COLLOCATION UTIUTY POLE ARCHITECTURAL SITE PLAN & GENERAL NOTES EXISTING 4' 0" WIDE LOCKABLE SWING GATES TO REMAIN, TYPICAL FOR [2] 7'-6" EXISTING SECTOR 'C' ANTENNA TO BE REPLACED, IN PLACE, WITH NEW SECTOR 'C' ANTENNAS, (TYP. (1) PER SECTOR). SEE DETAIL 3/A-3 FOR ADDITIONAL INFORMATION EXISTING 6'-O" HIGH CHAIN LINK FENCE WITH (2) 4'-0" WIDE LOCKABLE GATE TO REMAIN EXISTING SECTOR 'B' ANTENNA TO BE REPt.~CED, IN PLACE, WITH NEW ~CTOR 'B' AI,~TENNAS. (TYP. (I) PER SECTOR). SEE DETAIL 3/A-3 FOR ADDfflONAI. INFORMATION (2) EXISTING EQUIPMENT CABINETS TO REMAIN EXISTING CONCRETE SLAB TO REMAIN ~) ENLARGED EQUIPMENT PLAN SCALE: 3/16"=1'-0" NOTE: (1) CABINET TO BE ERICSSON RBS WCDMA MACRO OUTDOOR BASE STATION CABINET SUPPLIED BY T-MOBILE, AND INSTALLED 8Y CONTRACTOR, REFER TO CABINET MANUFACTURER SPECIFICATIONS AND DRAWINGS FOR MORE INFORMATION. SPECIFICATIONS FOR ERICSSON RBS 3106: 5,S5' TALL x 4.27' WIDE x 304' DEEP CELL CAPACITY: 1-12 CELL-CARRiERS PER CABINET ' WEIGHT: 1874 LBS FULLY EQUIPPED (SXA CONFIGURATION, 200 Ah BATTERY) ELECTRIC REOU:RED: 208-250 VAC PHASE), IO0-A3B VAC (2-3 PHASE) PURCELL EQUIPMENT CABINET MOUNTED TO UMTS CABINET ~ ~:~)_TYPICAL UMTS CABINET DETAILS SCALE: 3/8"=1' 0" NEW T-MOBILE BABE STATION CABINET SUB-BASE TO NEW PRECAST CONCRETE PAD WITH 1/2" S/S RODS SET IN HILTI HIT HY-150 CHEMICAL ANCHORS. MINIMUM 3-1/2" EMBEDMENT (TYP) (1) NEW UMTS CABINET SECURED TO PRECAST CONCRETE PAD, SET ATOP GRADED AREA WITHIN THE EXISTING EQUIPMENT COMPOUND. SEE DETAIL 2 THIS SHEET NEW T-MOBILE PURCELL EQUIPMENT CA~INET MOUNTED TO PROPOSED UMTS ROSS106 EQUIPMENT CA~INET N~/ 2" CONDUIT IN IRENCH TO BE ROUTED FROM NEW UNTS RBS3106 TO EXISTING METER AND 0ISCONNECT SWITCH AND NEW 2" CONI~JIT PROM N[~ PURCELL CA~INET TO TELC0 BOX FOR FlOR RUN, SEE ~ICAL DETAIL 2/A-3 FOR EXISTING SECTOR 'A' ANTENNA TO B~ REPLACED. IN PLACE. WITH NEW SECTOR 'A' ANTENNAS,[(TfP, (1) PER SECTOR). SEE (2) NEW T-MOBILE BOOSTER CABINETS, SET ATOP EXISTING EQUIPMENT PAD (I) EXISTING GPS UNIT MOUNTED TO EQUIPMENT CABINET TO REMAIN UNISTRUT PLO00 EQUIPMENT RACK TO DE HIGH STRENGTH HOT DIPPED GALVANIZED GALV. POST CAP 2"e GALV SCHEDULE 40 PIPE UNISTRUT PLO00 BRACE (AS ATTACH UNISTRUT TO POST WITH 3/8"e GALV. U-BOLTS. PRO.DE ALL NECESSARY HARDWARE WATERPROOF SEALANT 3/4" CHA~FER (TYP.) RESTORE EXISTING SURFACING AT AREAS DISTURBED BY ;, TO MATCH EXISTING 12"¢ SONOTUBE FORMED CONCRETE FOOTINGS PAINT PORTIONS OF POST TO BE EMBEDDED IN CONCRETE PAINT (TYP.) ~ DETAIL · UNISTRUT H-FRAME WILLIAM I~ COLLINS, AIA A R C H I T E C T S, LLP 'WFC i~.OJECT NO. I0-8705 · T...Mo' ile. Northeasl LLC 80UTttOLD 8UI~I'ATION MAIN ROAD SOUl. OLD, NY ! 1791 UI3058A COLLOC.~TION UTILITY POLE ENLARGED EQUIPMENT PLAN & DETAILS Sl~ NU~E~ T A-2 ~J~lr.0. EXISTING WOOD UTILITY POLE (TYP. AT ALL SECTORS) ~T.O.cABiNETsEX. EQUIPMENT GRADE ~'~ NORTHWEST ELEVATION SCALE: 1'= 10' O" T-MOBILE ANTENNAS (TYP. (I) PER SECTOR). SEE 84'-0" HIGH WOOD UTILI~ POLE TO REMAIN (2) EXISTING EQUIPMENT CABINETS ATOP EXISTING CONCRETE SLAB TO REMAIN EXISTING CPS UNIT MOUNTED TO EXISTING EQUIPMENT CABINET TO REMAIN EXISTING TELCO PANEL AND PRNME, BEYOND. TO BE REMOVED AND REP!.~CED, IN PLACE, WITH NEW UNISTRUT H-ERAME NEW PURCELL EQUIPMENT CABINET MOUNTED TO SIDE OF NEW UMTS EQUIPMENT CABINET NEW UMTS CABINET SECURED TO PR[CAST CONCRETE PAD, SET ATOP GRADED AREA '//',THIN THE EQUIPMENT COMPOUND, SEE DETNL 2/A-2 (2) NEW BOOSTER CABINETS ATOP EXISTING CONCRETE SLAB. SEE DETAIL 4/A-3 (~ TYP. UTILITY TRENCHING DETAIL SCALE: 5/4" : 1'-0" 4 ?/s" k FRONT VIEW IANTENNA -MFG: ANDREW - DECIBEL -PART NO.: ADFD182A-6565B-XDM -±45' DUAL POLE QUAD ANTENNA *FULLY COMPATIBLE WITH ANDREW TELETILT® REMOTE CONTROL ANTENNA SYSTEM (~) ~ICAL ANTENNA DETAILS SC L~.1/2" Z ~ DETAIL ® BOOSTER CAB. SCALE: 3/8" = 1'-0" WILLIAM F. COLLINS, AIA A R C H I T E C T S, LLP WFC PROJECT NO. 10-,8705 · T...Mobile- Northeast LLC $OUTHOLD SUBSTATION MAIN ROAD SOUTHOLD, NY 11791 LI I 3058,4 DI~ION ~ COLLOCATION UTILITY POLE SHEBT TITLI] NORTHWEST ELEVATION & DETAILS ANTENNA SCHEDULE MANUF - MODEL# ANDREW: ADFDI82A 6565B-XDM ANDREW: ADFDI82A-6565B-XDM ANDREW: ADFD102A-6565B-XDM ~ ANTENNA SCHEDULE SCALE: N.T,$. BILL OF MATERIALS DESCRIPTtON MANUFACTURER PART # NORTEL S1BOO0 BTS NORTEL GROUND KITS EX. CABLEWAVE DIN(M)-DIN(M) I/B" - 8'-0" SUPERFLEX JUMPERS CABLEWAVE DIN(M)-DIN(M) I/2" - 6'-0" JUMPERS CABLEWAVE EX. DIN(F) CONNECTORS ANTENNA MOOEL NO. ADFD182A65BR2DM BOOSTER CABINET PPC CABINET UMTB CABINET ANDREWS MADNETEK CCi MARCON~ ERICSSON RBS 3106 (~ BILL OF MATERIALS SCALE: NTB LEGEND NEW EXISTING FUTURE r-----I TYP. SECTOR CABLE POL ANTENNA (TYP 1 PER SECTOR) STO JUMPERS CABLE CABLES RAC24 8'-0" SUPERFLEX JUMPERS GENERAL NOTES 1. ALL INDICATIONS OF- NORTH ARE EOR REFERENCE ONLY. CONTRACTOR TO VERIFY iN FIELD TRUE NORTH PRIOR TO SECTOR ANTENNA INSTALLATION. 2. CABLE LENGTHS LISTED ARE APPROXIMATIONS BASED ON THESE PLANS AND ARE NOT INTENDED TO BE USED FOR ORDERING CABLE. ALL CABLE LENGTHS MUST BE V.I.E. 5. THE CONTRACTOR SHALL INSTALL BRASS TAGS (SUPPLIED BY T-MOBILE) AT EACH END OF ALL ANTENNA CABLES DENOTING THE NUMBER OF TAPE MARNING BANDS AND COLOR OF TAPE MARKING BANDS. 4. ANTENNA CABLES WILL BE COLOR CODED AT THE ANTENNA. FILTER INJECTION CABINET, JUMPER CONNECTIONS AND THE BTS CABINET 5 THE CONTRACTOR SHALL iNSTALL DRIP LOOPS ON ALL ANTENNA AND JUMPER CABLES. B THE CONTRACTOR SHALL INSTALL ADDITIONAL CABLE SUPPORTS AS NEEDEB TO MAtNTAIN A MINIMUM SPACING OF 5'-0" ON CENTER. 7. THE CONTRACTOR WILL RECORD THE LOCATION AND SERIAL NUMBERS OF ALL ANTENNAS, ANTENNA CONTROLLER MOTORS. AND THEIR CORRESPONDING INSTALLED LOCATION AT THE TIME OF CONSTRUCTION. B ALL ANDREWS MOTORS ARE GENDER SPECIFIC, AND WILL BE WIRED STARTING WITH THE MALE ENO OF THE CABLE AT THE BTS AND CONTINUE ALONG THE BUN FOLLOWING THE 'FEMALE UP RULE'. MIN. CABLE BEND~G RADIUS UNLESS OTHERWISE NOTED: FOR SECTORS 0'-100' USE 7/B" e CABLE FOR SECTORS ~01'-150' USE 1-1/4" · CABLE FOR SECTORS 1Sl'& ABOVE USE EX e CABLE TX/EX TX/EX TX/RX TX/RX TX/RX TX/RX ]X/RX TX/RX TX/EX TX/RX TX/RX TX/RX TX/EX TX/EX TX/RX IX/EX TX/RX IX/RX TX/EX TX/RX ~ ~ TX/EX L~ TX/RX o ? TX/RX z TX/EX TX/RX TX/RX TX/RX TX/RX  EX SUPERFLEX JUMPER (TYP.) ~EX. JUMPER (TYP) / DIN (r) / SECTOR 'A' DIN (F) / DIN (M)/ EXISTING CABLE (TYP FOR SECTOR "A") DiN iM')/ OUAD POL SECTOR 'B' DIN (F) J]n1DDIN (M)~ [~EXISTING CABLE (TYP FOR SECTOR "B") DINDIN (M)(F) OU~O POL SECTOR 'C' DIN (F) EXISTING CABLE (TYP FOR SECTOR "C") DIN (F) ~ DIN (M) QUAD POL ~ I I [~,J~ ~[AND~R~E?: ~ADfD1~82~AF6~B~65BTX~D~, /1 WILLIAM F. COLLINE~ AIA A R C H I T E C T & LLP WFC FgOIECF NO. 10-8705 J · .Mobile- Northeast LLC ..~OUTHOLD SUBSTATION MAIN ROAD $OLrrHOLD, NY I 1791 UI3058A DB~GN I'Y~ COLLOCATION U~UTY POLE ANTENNA SCHEDULE, B.O,M., & ROUTING SCHEMATIC ABBREVIATIONS AND LABELS .... NE ---- NEW UNDERGROUND ELECTRIC '~ " ] NEUTP~L ~ .... E - -- EXISTING UNDERGROUND ELECTRIC ~) DESIGN CRITERIA CONTRACT A SEPARATE VENDOR FOR THE ACTUAL (~ E~ECTR,CAL DES,O. AND S.A~L COORD,.ATE T.E ABBREVIATIONS ABBREVIATIONS AND LABELS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHEO GRADE AWO AMERICAN WIRE GAUGE C CONDUIT CB CIRCUIT BREAKER EMT ELECTRICAL METALLIC TUBIND DND GROUND MC METAL CLAD CABLE MOB MAIN CIRCUIT BREAKER WILLIAM F. COLLINS, A R C H I T E C T ~, LLp ~ ~ NO. 10-8705 · ...Mobile- Northeast LLC $500 SUNRI$[ HWY. SUIT[ 0-203 SOUTHOLD SUBSTATION MAIN ROAD SOUTHOLD. NY 11791 LII3058~ D~IGN TYPE COLLOCATION UTILITY POLE SH~Er Tfrt,E GENERAL ELECTRIC NOTES & SYMBOLS F-I NEW T-MOBILE EQUIPMENT. ---- ] ('-- A R C H I T E C t ~ L Lp '~ ', I EXISTINC NO CHANCE ....... . "' ~ RISER DIAGRAM L,~, CONTACT NAME: WARREN STOKER (XXX) XXX-XXXX ~ I j ......... ~ BTS "1" BTS "2" UMTS ~E S C PROPERTY LINES (TYP) ~ J ~ I ~ O ............ ~ ~ / ~ ..,,"' 1 ~ ~ ,/ /!.~S 45'38'10' W .16~07 -~ ~z/~~d K~Y NOTES ~ SO'HOLD. ~ 11791 MAIN ROAD ~NORTEL SOB BASE gROUND BAR (N6~) ~ EX gOAXlAL CABL~ GROUNDING KIT ~TELcoCONDUIT~oxFROM MAIN DEMA~C SOURCE TO LII3OSSA J / SERVICE PLAN DISTURBANCES SUCH AS CORE DRILLING SHALL BE ~8~ plAY'AM : RGS ELECTRICAL CONDUITS ~ NEW LOCAL WEATHERPROOF SCALE: I" = 100' COORDINATED WITH THE BUIL01NG'S "ANAGE.ENT NORTH ~' oCAL[ NO oCAL[ ~CONTR~CToRTELCO DE.ARC SUPPLIED BOX INSTAUEOBy T .OBILEBY ~ PURCELL 2" RGS TELOOcABiNE,CONDUIT FOR FIBER RON 10 E--2 8 J O~OUND~I~ KEY NOTES X X~; (~) NORT[L OROUNO BAR (NOB) ~ SECTOR CABLE GROUND BAR (SCGB) ~ ~ ~6 AWG STR~DED GREEN THWN INSULTED COPPER WIRE FROM COAXIAL GROUND KITS (CGK) AT ~ . ~ ~ ~ COMMUNICATIONS CABINET ENTRY. TO SCG8 (~PIC~ FOR ~CH ANTENNA CABLE.) ~ ~2/0 AWG SOLID TINNED COPPER WIRE FROM EACH SCOB TO EOUIPMENT GROUND RING (EGR) ~ ~ AWG SOLIO TINNED COPPER WIRE FROM EACH NOB TO [GR W · "-. x ~ ~2 AWG SOLID TINNED COPPER WIRE FROM UNISTRUT METER FRAME TO EGR. ~ ~ ~2 AWG SOLID TINNED COPPER WIRE FROM CABLE TRAY TO ~ ~ ~ COAXIAL GROUND KIT (CGK) DO ~T INSTALL ON B~NDS. (S~E DETAILS 2 & 3/E-4,) ~ ~ ~. 1~705 . ~. ( ~ ¢ ~ , . * '6 AWG STRANDED GREEN THW' INSULTED COPPER WIRE FROM CGK TO SECTOR ~T/NNA GROUND ® ~U'j~_ ~~ ~ STEEL POLE GROUND B~. (PGB) - ~ ~ ~2/0 AWG SOLID TINNED COPPER WIRE FROM PGB TO NEW ST[EL POLE GROUND RING. (PGR) J ~ ~2/0 AWG SOLID TINNED COPPER WIRE FROM ~TTERY CABINET GROUND B~ TO EGR. BELOW GR~E. CONNECTED TO GROUND R~S THAT ARE INCORPORATED INTO EXTERIOR GROUND RING. ALL CONNECTIONS ARE TO BE ~ WELDED ~D SP~O WITH COLD-~VANIZED PNNT ~ ~2/0 AWG SOLID TINNED COPPER WIRE EQUIPMENT GROUND RING (EGR) BURIED 42" M~N. BELOW ~ GROUND RODS THAT ~E INCORP~TED INTO EXTERIOR GROUND RING. ~C~~~ ,/ e ~ ~L CONNECTIONS ~E TO BE C~ WELDED AND SPAYED WITH COLD-G~V~IZED PNNT. I ~OT[. GROUNDING LEGEND: ~ BURIED 36" BELOW FIN. G~E (SEE DUAIL 3/E-5.) REFER TO GROUN01NG SCHEMATIC · GROUNDING SYSTEM CONNECTIONS~ ~ ~6 AWG ST~NDED COPPER WIRE JUMPERS CONNECTED :~,m~... GROUNDING PLAN ~.~ ~,ou.o~.~ .o~[s ~/~-, ,o. ~ CO~,~R ~,ou,o ,ODS (CA~ W~ ALL CO..~C~,O.S) .RD. ,[,C~ S~CT~O,S TO ,[~C~ ,OSTS SCALE: 1/8"=1'-0" ADDITIONAL INFORMATION. ~ COPPER GROUND ROD IN TEST WELL NORTH ~ ~2 AWG STR~DEO TINNE0 COPPER WIRE FROM FENCE POSTS TO EGR. (MULTIPLE L~DS REQUIRED. SEE P~ FOR L~ATIONS.)  ~ ~2 AWG STR~DED TINNED COPPER WIRE FROM EACH BOOSTER CABINET GROUND BAR TO EGR NOT~; (MULTIPLE L~DS REQUIRED. SEE PLAN FOR LOCATIONS.) BETHOOOL00YFoRTHrS S'EOIFIcO[TAIL DE~JgTSA'TENNA~OR ~"E~AL ~OUNOINOMoUNTIN~ANTEN"A ~ANTENNA MOUNTJN~ ~ '~ AW~ SOUD TINNE0'~/O AW~ COPPER WIRE FROM [LEC PANEL ~"OUNg BAR TO [~R' ~ .Mob ? PIPE AND ~ ~2 AWG SOLIO TINNED COPPER WIRE FROM TELCO PANEL GROUND BAR TO EGR. INSTAL~TIONS, SEE ARCHITECTURAL DRAWINGS RE~TED MOUNTING ~RDWARE ~ SOLID TINNED COPPER WIRE FROM RBS 3106 GROUND BAR TO EGR. Northeast L EXISTING 1/2" COAXIAL JUMPERS 35~ SUNRISE H~.J ~P MAIN ROAD/ ANEL ANTENNA (SEE ANTENNA  SCHEDULE. DWG A-4) SO~O~,~ 11791 ~T~P. x w UI~O58A 1 ,%__ - U~ POLE TYP ~ ~ J COMMUNICATIoNEXIST~NG ANTENNAEQuiPMENTCOAXIAL CABLE TO EQUIPMENT GROUNDING EXISTING GROUND LEAD TO MASTER GROUND PLAN ~ DETAILS ~P. ANTENNA GROUNDING D~AII.BAR SCALE: NO SCALE E-3 , (SECTOR 'A') MULTIPLE COAXIAL (~GROUNB IYP UPPER PORTION OF EXISTING POLE BOTTOM OF EXISTING POLE EDSDNG BCW ('P~P) MULBPLE GROUND ROOS (SECTOR 'B') ANTENNA SUPPORT ~ ASSEMBLIES TYP (SECTOR 'C') (SECIOR REFER TO l/A-2 FOR NEW EQUIPMENT TO BE INSTAL~'ED AND GROUNDED ACCORDli~GLY. (SECTOR 'A') (SEClOR 'B') (SECTOR 'C') (GPS) (~) GROUNDING SCHEMATIC SCALE: NO SCALE ~CONDUITS (SEE GROUNDING NOTE #15) SEE GROUNDING KEY NOTES, DRAW)ND E-3. (TYp.) JUMPER FROM ANTENNA CONNECTORS~ GROUND WIRE TO BE CRIMPED TO #2 SOL~D TINNED GROUND WIRE TO BROUNO COAXIAL CABLE BETWEEN ANTENNA AND BTS JUMPERS & SCOTCH COTE)~ STD. CABLEWAVE~'~''''~''~'~'"~ KIT (TYP,) DO I~OT INSTALL GROUND KIT AT BETWEEN ANTENNA JUMPER CABLE A BEND AND ALWAYS DIRECT AND BTS JUMPERS PROM BTS GROUND WIRE DOWN TO CIBBE. CABLE GROUNDING KiT DETAILS (EXISTING) SCALE: 3"= I '-0" GRO~UNDING NOTES: ALL GROUNDING SHALL COMPLY WITH THE MOST RECENT REQUIREMENTS OF NEC ARTICLES 250 AND 810 AND T-MOBILE STANDARDS ALL DETAILS ARE SHOWN IN GENERAL TERMS ACTUAL GROUNDING INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. IT IS NOT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO DEPICT EVERY PIECE OF EOUIPMENT AND DETAIL BUT RATHER TO SHOW SYSTEMS TO BE INSTALLEB. PROVIDE SYSTEMS WITH ALL APPURTENANT EQUIPMENT OR COMPONENTS, WHETHER SHOWN OR NOT, TO MAKE A COMPLETE OPERATIONAL SYSTEM IN COMPLIANCE WITH THE CRITERIA SET FORTH. RESISTANCE TO GROUND SHALL BE 10 OHMS OR LESS, MAX CONTRACTOR SHALL EMPLOY A GROUNDING EVALUATION COMPANy SUCH AS D&H DEVELOPMENT (B1S-4B1-29Bg) OR ~QUAL NOTIFY T-MOBILE PROJECT MANAGER IF THERE ARE ANY SITE SOIL/RESISTANCE CONDITIONS THAT MAY PRECLUDE OR HAMPER A PROPER AND COMPLIANT 8 ALL BENDS, CURVES, AND CONDUCTOR SPLICES SHALL BE IOWARDS THE GROUND LOCATION (GROUNDED END) OF THE CONDUCTOR AND SHALL MEET OR EXCEED MINIMUM BENDING RADII. GROUNDING CONDUCTORS #6 AND LARGER SHALL HAVE A MINIMUM BENDING RADIUS OF 12', GROUNDING CONDUCTORS #6 AND SMALLER SHALL HAVE A MINIMUM BENDING RADIUS OF 8". 9 UNLESS OTHERWISE NOTED. GROUNDING CONDUCTORS 10. GPS TRANSMISSION LINES SHALL HAVE AT LEAST (1) GROUND KIT INSTALLED AT THE WAVEGUIDE ENTRANCE PORT. 11. PROVIDE ALL NECESSARY GROUNDING KITS AND HARDWARE, ' ~JUMPER CABLE CONNECTORS~COAXlAL CABLE ~TAPE (1 LAYER) VERTICAL CONNECTIONS SHOULD BE TAPED FROM THE BDT[OM UP TO ~TEP 3 TAFFY TAPE) CONNECTION. ~ AND ,3 LAYERS ,3/4" TAPE, ALL TXPE J ~UR[[ ~YERS OF ELECIRIC~ ~ AN~NNA CABLE WA~RPR~FING DETAIl hi tp://www.wfcala.c eJ WJ~2 J~..OI~2T NO, 10-8705 · T...Mobile. Northeast LLC ~0U17t0I~ SD'Bi~ATION MAIN ROAD SOUTHO~, ~ I 1791 UI3058A CO~O~ON UTIU~ POLE GROUNDING SCHEMATIC A DETAILS