Loading...
HomeMy WebLinkAbout37012-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 8/27/2012 CERTIFICATE OF OCCUPANCY No: 35914 Date: 8/27/2012 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 165 Love Ln, Mattituck, SCTM #: 473889 Sec/Block/Lot: 141.-4-31.4 Subdivision: Filed Map No. conforms substantially to the Application for Building Permit heretofore 2/3/2012 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and new foundation under an existing commercial building as applied for. Lot No. filed in this officed dated 37012 dated 2/24/2012 The certificate is issued to Totora, Leonard&Totora, Louise (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 8/24/12 37012 8/13/12 /~ Gary Bulkins~./ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37012 Permission is hereby granted to: Totora, Leonard & Totora, Louise Date: 2/24/2012 420 Lenox Rd Huntington Sta, NY 11746 To: construct a new foundation under an existing building & alterations to an existing commercial building as applied for At premises located at: 165 Love Ln, Mattituck SCTM # 473889 Sec/Block/Lot # 141 .-4-31.4 Pursuant to application dated To expire on 8125/2013. Fees: 2/3/2012 and approved by the Building Inspector. NEW COMMERCIAL, ALTERATION OR ADDITIONS CO - COMMERCIAL Total: $794.00 $50.00 $844.00 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildiugs, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less thao 2/10 of I% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for tile building. 6. Submit Planuing Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" laud uses: 1. Accurate survey of property showing all property lines, streets, building and uuusual natural or topographic features. 2. A properly completed application and consent to iuspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Building Inspector slmll state the reasons therefor iii writing to the applicant. C. Fees I. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupaucy on Pre-existing Buildiug- $100.00 3. Copy of Certificate of Occupancy - $.25 - 4. Updated Cellificale of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Cmnmercial $15.00 Old or Pre-existiug Building: ~/ (check one) Street Ham let T~ToB Iql mo k New Construction: Location of Property: '""-J [(O ~-- House No. ©wner or Owuers of PropetScy."~ ]..C:,k)l,~ol~ Suffolk County Tax Map No 1000, Section Sufidivision Permit No. Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ --~(~ , 0 (~ Date of Permit. Filed Map. Lot: Applicany: Underwriters Approval: Final Certificate: 'q~ (check one) Town Hall Annex 54375 Main Road P.O. Box 1179 Southold. NY 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 roger r chert~town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Torora &ddress: 165 Love Lane City: Mattituck St: NY Zip: 11952 Suilding Permit#: 37012 Section: 141 Block: 4 Lot: 31.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE 3ontractor: DBA: Custom Lighting of Suffolk License No: 38893-me SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage Service 1 ph 2~200~ Service 3 ph Main Panel ~ Sub Panel Transformer Disconnect ~200a Other Equipment: INVENTORY Hot Water GFCI Recpt NC Condenser Single Recpt NC Blower Range Recpt Appliances Dryer Recpt Switches Twist Lock 62ft lighting track Notes: Ceiling Fixtures [~ HID Fixtures Wall Fixtures ~ Smoke Detectors Recessed Fixtures ~.~ CO Detectors Fluorescent Fixtun ~ Pumps Emergency Fixture Time Clocks Exit Fixtures [~ TVSS 1-paddle fan, 3-combination exit/emergency lights, 2-combination smoke/co detec Inspector Signature: Date: Aug 13 2012 81-Cert Electrical Compliance Form.xls Town Hall Annex 54375 Main Road P.O. Box I 179 Southold, New York 11971-0959 BUILDING DEPARTMENT TOWN 01' SOUTHOLn Telephone (631) 7654802 Fax (63 I) 765-0502 AUG 2 3 2012 ~ID5 D£P]. TOWN OF SOUTHOL9 CERTIFICATION Date: ~. 3 "'/- I ~ Building Permit No. 2 ~ 0 I 2 Owner: (Please print) Plumber: ~'Alx~/ /3 o F/</~'S (Please print) I certify that the solder used in the water supply system contains less than 2/10 o'f 1% lead. Sworn to before me this ~/-~ dayof , ~,~ kX~~- 20\q- ALBENA MITOVA NOTARY PUBLIC-STATE OF NEW YORK NO. 01 MI6249841 Qualified in Suffolk County My Commls$1oll Expffea O¢lol~el 1 I, 2015 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [~FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRI.CAL (ROUGH) [ ] ELECTRICAL (FINAL) DATE ~ ~//~//~-~ INSPECTOR /~'~~ J7o/;- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ~FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]ROUGH PLBG. [ ] FOUJ~iBrATION 2ND [ ]INSULATION [~'~MING/~ [ ]FINAL ] FIREPLACE & CFIIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESIS'rAITr PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE /'~/~! .///~/'/ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 [ ] FOUl 1ST [] 2ND / STRAPPING [ ] FIREPLACE & CHIMNEY ROUGH PLBG. INSULATION FINAL FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FIliAL) REMARKS: 4~-'/~~ ~t'g/~:-" / TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION l ST [ FOUNDATION 2ND [ FRAMING / STRAPPING [ FIREPLACE & CHIMNEY [ FIRE RESISTANT CONSTRUCTION [ ~'~LECTRICAL (ROUGH) [ REMARKS: ROUGH PLBG. INSULATION FINAL FIRE SAFETY INSPECTION RRE RESISTANT PENETRATION ELECTRICAL (FINAL) INSPECTO~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE~AFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ,-']lqRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] EL~_ECTRICAL/(FII..~KET--~'~ REMARKS.LL' ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTI/ON FOUNDATION 1ST [ ] ~tI'GH PLBG. FOUNDATION 2ND [/,/]/'INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELE~K~q~ REMARKS: DATE INSPECTOR~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING/STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ [ ] ELECTRICAL (ROUGH) REMARKS: [ ] ROUGH PLBG. [ ]INSULATION ]FINAL ]FIRE SAFETY INSPECTION ]FIRE RESISTANT PENETRATION ~] ELECTRICAL (FINAL) DATE ~~~-~----- I NSPECTO~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO,~GH PLBG. [ ] FOUNDATION 2ND [ ]~ULATION [ ] FRAMING/STRAPPING [//] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUOTION [ ] RRE RESISTANT PENETRATION [ ] ELECTRI~ROUGH) [ ] ELECTRICAL (FINAL) REMARKS..,~/ - ~ ~,~2 DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-¶ 802 INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: ~ ~ DATE ~ INSPECTOR .TOWN OF'SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork.net Examined ,20 Approved 0~'~ D~noved FEB -3 2012 BLDG DEPI. TOWN OF SOUE~OLD PERMIT NO. BU1LD1NG PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS Doq]{S g. ,20 I~. a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. lfno zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections~ ~ (Signature of applicant or name, if a corporation) P..e.8ol( qf0cwhc- , I lqa/ (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises L~--astYzgC~ T'o~oC(K (hq& J,,-OL)'{$e T-O4-O~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: I T Loue House Number Street Hamlet County Tax Map No. 1000 Section I ~l Block t"l Lot ..~[, t~ Subdivision Filed Map No. Lot 2. State existing use and occupancy of p. remises and intended use and occupancy of_propo, sed construction: a. Existing use and occupancy ~ccvv~_<-[,~ ~ ~/~.~ \ ~\o~ ar ~elr~, i b. Intended use and occupancy ~ cc'~lx3,[ ~. 3. Nature of work ~check which applicable): New Building Repair .~ Removal Demolition - 4. Estimated Cost lOOjO00 5. If dwelling, number of dwelling units If garage, number of cars Fee Addition Alteration Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ~ O, Height. I ~,, ~ t Number of Stories Dimensions of same structure with alterations or additions: Front 0,o. 3 Depth ;~ q. 3' Height ~ (o-O' Number of Stories 8. Dimensions of entire new construction: Front ~o. f' Rear ~' '~ ~ Height [ (o .O~ N umber of Stories ~ 10. ~. 9. Size of lot: Front ',~ (~ ' 0 Rear .~ ~,' ~ 7 Depth -~O . O .Depth Rear .Depth ~c~,3 r 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated ]4 ~3 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO 13. Will lot be re-graded? YES NO ~/~ Will excess fill be removed fmm pre~i, ses? YES NO 14. Names ofOwnerofpremises L~L~i$~ ~¥1~a'~qAddressH°~~r~'-'~u~lr~L ~ Vel PhoneNo. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO v-/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO V'/ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ~ 1(2.~r-(~ ~'fS'O,q.o,h b being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, CONNIE D. BUNCH (S)He is the ~-~.I[Ial' f~O-- JfOC' [ [ ~.~--~ C~ Notary~e.Pul>liC'-n'~ -sUe! 8-r'nnoState of New Yo~k (Contractor, Agent, Corporate Officer, etc.) Qua#lied in Suffolk County Commission Expires April 14, of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi~ . ~'~(~/',~. day of ¢~ 20~ Notary Public Signature of Applicant TOwn of, Southold ~ ~ !Erosion, Sedimentation & Storm. Water Run.off ASSESSMENT FOR~" ~ ¢ t.oc~o~ $.C.T,~. ~ THE FOU.OWING ACTIONS MAy REQU!,a_; THi; ~:¥_~_u.!_~$10N OFA STOI~-~5?.~TF~ 6EADING~ DRAII~AGB ANB r., ,~!~... ~O~ PLAN ~sOng ~ I~M~ ~ ~ ~ Cubic y~ of ~te~ ~.~y Pam~ E~ an (5,~ S.F.) ~re F~t 6 Is ~em a Na~ Wa~ Site? ~ ~ P~ T~ ju~di~ ~ml ~ ~p ~ul~: ~ ~in ~~ ~s~M~(t)a~ w~ ~ Rfl~ (15) ~t ~V~ml ~O to ~'A~OF~YO~ ~. ~ 0 ~ C~W OF .~.~ ............ ~t I ................ ~.~.~.~ ................... ~g ~ ~m, de~ ~d ~ ~t ~she is ~e ap~t for P~ .................. ~""i~7~.~~;~ ............................................ ~ ~or ~p~n~e of ~e ~ ~ ~ ~d ~ d~y au~o~ ~t ~ ~rk'~ ~ ~o~ed in ~e m~ set f~ ~ ~e a~on ~ed ~. S~ to ~o~ me ~s; ........ ......................... ......... (~) FORM - 06110 CONNIE D. BUNCH Notary Public, State of New York No. 01BU6185050 Qualified in Suffolk County ^ Commission Expim~ April 14, 2U_~g Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 119714)959 Telephone (631) 7~5-1809~ roosr, richerid~ (v~n~Js) o~ ueu~l~o~.nv, us BUILDING DF~PARTMENT TOWN OF SOUTHOLr~ APPLiCATiON FOR ELECTRICAL INSPECTION ~,ompany Name: Name: License No.: Address: Phone No.: REQUESTED BY: ~"~ ~'~Of-,Oc3~,.~ Date: JOBSITE INFORMATION: (*IndiCates required information) *Name: '-~(~'~'0 ~- ~ *Address: *Cross Street: *Phone No.: Permit No.: Tax Map District: \ (0% 1000 Section: I ~ I Block: *BRIEF DESCRIPTION OF ~V¥ORK (Please Print Cleady) 60 ~"-~, .- (Please Circle All That Apply) *Is job ready for inspection: *Do you need a Temp Certificate: Temp 'Information (If~.~ed}~ *Service Size: ~Phas~ 3Phase *New Service: Re-connect Additional Information: 82-Request for Inspection Form 100 Underground ~/NO YES / {~ Final 150 ~ 300 350 400 Other Number of Meters Change of Service Overhead PAYMENT DUE WITH APPLICATION COMcheckSoftware Version 3.9.0 Envelope Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: 165 Love Lane Construction Site: 165 Love Lane Mattituck, NY 11952 Owner/Agent: Seth Howe STUDIOHOWE 136 Main Street Amaganseft, NY 11930 2123666400 seth@sfadiohowe.com FEB Designer/Contractor: Richard Principi Pdncipi Construction 551 Moctauk Highway Amaganseft, NY 11930 1 0 2012 BLDG. DEPI'. TOWN OF SOUTHOLD Section 2: General Information Building Location (for weather data): Suffolk, New York Climate Zone: 4a Building Type for Envelope Requirements: Non-Residential Vertical Glazing / Wall Area Pct,: 9% Activity Tv~eCst Floor Area Retail 650 Section 3: Requirements Checklist Climate-Specific Requirements: Component Name/Description Gross Cavity Cont. Propeeed Budget Area or R-Value R-Value U-Factor U-Factor(a) Perimeter Roof 1: Attic Roof with Wood Joists 650 38.0 0,0 0,027 0.027 Exterior Wall 1: Wood-Framed, 16" c.c. 800 19.0 0.0 0.067 0.089 Window 1: Wood Frame:Double Pane with Low-E, Clear, SHGC 154 -- -- 0.300 0.400 0.40 Door 1: Wood, Swinging 45 -- -- 0.500 0.700 Basement Wall 1: Solid Concrete:10" Thickness, Normal Density, 900 20.0 0.0 0.059 0.579 Furring: Wood, Wall Ht 8.0, Depth B.G. 0.0 Floor 1: Wood-Framed 650 38.0 0,0 0.027 0.033 (a) Budgel U-factom are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: [] 1. All joints and penetrations are caulked, gaskefad or covered with a mois{ure vapor-permeable wrapping material iosfatfad in accordance with the manufacturer's installation instructions. ~1 2. Windows, doors, and skylights certified as meeting leakage requirements. [] 3. Component R-values & U-factors labeled as certified. ~1 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. [] 5. 'Otber~ components have supporting documentation for proposed U-Facfars. r~ 6. insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation, [] 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with mofodzed dampers. Project Title: 165 Love Lane Data filename: C:\Users\HOWE\Desktop\LoveLane~Energy report\LoveLane 2.cck Report date: 02/08/12 Page 1 of 12 [] 8. Cargo doom and loading dock doors ars weather sealed. [] 9. Recessed lighting fixtures installed in the building envelope ars Type lC rated as meeting ASTM E2831 ars sealed with gasket or caulk r~ 10. Building entrance doom have a vestibule equipped with self..ciosing devices. Exceptions: ~1 Building entrances with revolving doors. [] Doors not intended to be used as a building entrance. [] Doors that open directly from a space less than 3000 sq. fi. in ama. ,~] Doors used primarily to facilitate vehicular movement or matahals handling and adjacent personnel doors, [] Coors opening directly from a sleeping/dwelting unit Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9,0 and to comply with the mandatory requirements in the Requirements Checklist. When a Registered D~sign Professional has stamped and signed this page, they are attesting that to the pest of his/her knowledge, belief, and professional judgment, such plans or specifications ars in compliance with this Code. Nar~e - 3:itle ' I Datet ' ~ Project Title: 165 Love Lar~ Report date: 02/08/12 Data filename: C:\Users\HOWE\Desktap\LoveLane\Energy report~oveLane 2,cck Page 2 of 12 COMcheck Software Version 3.9.0 Interior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: 165 Love Lane Construction Site: 165 Love Lane Mattituck, NY 11952 Owner/Agent: Seth Howe STUDIOHOWE 136 Main Street Amagansett, NY 11930 2123666400 eelh@studiohowe,nom Designer/Contractor: Richard Pdncipi Pdncipi Construction 551 Montauk Highway Amagansett, NY 11930 Section 2: Interior Lighting and Power Calculation A Ama Category B C D Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Retail 650 1,5 975 Total Allowed Watts = 975 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture iD: Description I Lamp I Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Retail (650 sq.ff.) Linear Fluorescent 1: 48" T8 25W (Super T8) / Electronic 2 8 25 200 Total Proposed Watts = 200 Section 4: Requirements Checklist Lighting Wattage: [] 1. Tolal proposed watts must be tess than or equal to total allowed watts, Allowed Watts proposed Watts Complies 975 200 YES Controls, Switching, and Wiring: [] 2, Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. [] 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: L~ Contiguous daylight zones spanning no more than Iwo orientations are allowed to be controlled by a single controlling device. ~] Daylight spaces enclosed by walls or ceiling height partitior~s and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. [] 4. Independent controls for each space (switch/occupancy sensor). Exceptions: [] Areas designated as secudty or emergency areas that musl be continuously illuminated. Prdject Title: 165 Love Lane Report date: 02/08112 Data fllename: C:\Users\HOWE\Desktop\LoveLane\Energy report\LoveLane 2.cck Page 3 of 12 ~1 Lighting in slairways or corridors that are elements of the means of egress. [] 5. Master switch al entry to hotel/motel guest room. ~1 6. Individual dwelling units separately metered. [] 7. Medical task lighting or arlJhistory display lighting claimed to be exempt from compiianse has a control device independent of the conlml of the nonexempt lighting. ~1 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 pement by either controlling ell luminairec, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of of her lamps, or switching each luminaire or each lamp. Exceptions: [] Only one luminaire in space, [] An occupant-sensing device controls the area, ~1 The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ~1 Areas that use less than 0.6 Watts/sq,ff. [] 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: [] Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safely or secudly. [] 10. Photocell/astronomical time switch on exterior lights. Exceptions: ~1 Lighting intended for 24 hour use. [] 11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: [] Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. ll, ll~. ,ill llilllllll* i ~l~_~*~'~l'~ 'l~ [ _l_~_~ll ........... r_-iiii[?lll~,T Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application, The proposed lighling system has been designed 1o meat the 2010 New York Energy Conservation Construction Code requirements in COMcheckVersion 39.0 and to comply with the mandatory requirements in the Requirements Checklist. Nam;- mitl~ ' t -- Signature Date I , Projecl Title: 165 Love Lane Report date: 02/08/12 Data filename: C:\Users\HOWE~Desktop\LoveLane\Energy repart\LoveLase 2.cck Page 4 of 12 COMcheck Software Version 3.9.0 Exterior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Construction Site: 165 Love Lane Maitituck, NY 11952 Project Type: New Construction Project Title: 165 Love Lane Exterior Lighting Zone: 2 (Neighborhood business district) Owner/Agent: Seth Howe STUDIOHOWE 136 Main Street Amagansett, NY 11930 2123666400 seth@studiobewe~com Designer/Contractor: Richard Priocipi Principi Construction 551 Moctauk Highway Amaganseit, NY 11930 Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts I Unit (B x C) Main entry 1 It of door width 20 Yes 20 26 Total Tradable Watts* = 20 26 Total Allowed Waits = 20 Total AJlewed Supplemental Watts** = 600 · Wattage tradeoffs ara only allowed between tradable areas/surfacas. ** A supplemental allowance equal to 600 watts may be applied toward compliance of beth non-tradable and tradable araas/surfaces. Section 3: Exterior Lighting Fixture Schedule A Fixture ID: Description I Lamp/Wattage Per Lamp I Ballast B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Main entry (1 It of door width}: Tradable Wattage Compact Fluorescent 1: Twin Tube 13W/Electronic 1 2 13 26 Total Tradable Proposed Watts =26 Section 4: Requirements Checklist Lighting Wattage: [] 1. W~thin each non-tradable ama/surface, total proposed watts must be less than or equal to tdtat allowed watts. Across all tradable areas/surfaces, total proposed waits must be less than or equal to total allowed watts. Compliance: Passes using supplemental allowance walls. Controls, Switching, and Wiring: [] 2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. [] 3, Lighting not designated for dusk-tc-dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. [] 4, Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. [] 5. All time switches are capable of retaining programming and the time setting dudng less of power for a period of at least 10 houm, Project Title: 165 Love Lane Report date: 02J08/12 Data filename: C:\Users\HOWE\Desktop\LoveLane\Energy repori\LoveLane 2.cck Page 5 of 12 Exterior Lighting Efficacy: [] 6. Allextarior buildinggroundsluminairesthatoperatealgreaterthan 100Whaveminimumefficacyof601umen/watt. Exceptions: I-I Lighting that has been claimed as exempt and is identified as such in Section 3 table above. ~1 Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. [] Emergency lighting that is automatically off during normal building operation. [] Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations sabmilted with this permit application. The proposed lighting system has been designed to meel the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.0 and tu comply with the mandatoPj requirements in the Requirements Checklist. Name - ~tl~ ' I -- Signature Date ' Projecl Title: 165 Love Lane Report date: 02/08/12 Data filename: C:\Usars\HOWE\Desk~p\LoveLane~Energy rebort\LoveLane 2.cck Page 6 of 12 COMcheck Software Version 3.9.0 Mechanical Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type: New Construction Project Title: 165 Love Lane Construction Site: 165 Love Lane Mattituck, NY 11952 Owner/Agent: Seth Howe STUDIOHOWE 136 Main Street Amagansett, NY 11930 2123666400 seth@studiohowe.cem Designer/Contractor: Richard Principi Pdncipi Construction 551 Montauk Highway Amagansett, NY 11930 Section 2: General Information Building Location (for weather dale): Suffolk, New York Climate Zone: 4a Section 3: Mechanical Systems List Quantity_ System Tvoo & Descrietion HVAC System I (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 50000 kBtu/h, Efficiency = 82.00% Ec Cooling: 1 each - Split System, Capacity = 36000 kBfu/h, Efficiency = 14.20 EER, Air-Cooled Condenser, Air Economizer Section 4: Requirements Checklist Requirements Specific To: HVAC System 1: [] 1. Equipment minimum efficiency: Central Furnace (Gas): 80.00 % Ec [] 2. Equipment minimum efficiency: Split System: 9.50 EER (9,2 IPLV) [] 3. Discharge dampers prohibited with fan motors · 25 hp [] 4. Integrated air economizer requirad I~1 5. Cooling system provides a means to relieve excess outdoor air during e~3nomizer operation. [] 6. Hot gas bypass prohibited unless system has multiple steps of unloading or co~inuous capacity modulation I~1 7. Hot gas bypass limited to 25% of tofal cooling capacity Generic Requirements: Must be met by all systems to which the requirement is applicable: [] 1. Plant equipment and system capacity no greater than needed to meet loads Exception(s): [~ Standby equipment automalically off when primary syslem is operating [] Multiple units controlled to sequence operation as a function of load ~1 2. Minimum one temperafura control device per system [] 3. Minimum one humidity central device per installed humidification/dehumidification system I-I 4. Load calculations per ASHRAE/ACCA Standard 183. [] 5. Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2-hour occupant override, 10-hour backup Exception(s): [] Continuously operating zones [] 2 kW demand or less, submit calculations ~1 6. Outside-air source for ventilation; system capable of reducing OSA to raquirad minimum [] 7. R-5 supply and return air duct insulation in unconditioned spaces Project TitJe: 165 Love Lane Report date: 02/08/12 Data filename: C:\Users\HOWE\Oesktop\LoveLane\Energy reportM_oveLane 2.cck Page 7 of 12 R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception(s): ~1 Ducts located within equipment F"~ Ducts with intedor and extedor temperature difference not exceeding 15°F. [] 8. Mechanical fasteners and sealants used to connect ducts and air distdbufion equipment [] 9. Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics Exception(s): [] Continuously welded and locking-type longitudinal joints and seems on ducts operating at static pressures less than 2 inches w.g. pressure classification [] 10,Hof water pipe insulation: 1.5 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1.5 in, for pipes <=1.5 in. and 1,5 in, for pipes >1,5 in. Steam pipe insulation: 1.5 in, for pipes <=I,5 in. and 3 in. for pipes >1.5 in. Exception(s): [] Piping within HVAC equipment. [] Fluid temperatures between 55 and f05°F. [] Fluid not heated or cooled with renewable energy, [] Piping within room fan.coil (w~th AHRI440 rating) and unit ventilators (with AHRI840 rating). [] Runouts <4 ft in length. [] 11.Operation and maintenance manual provided to building owner [] 12.Thermostatic controls have 5°F deadband Exception(s): [] Thermostats requiring manual changeover between heating and cooling [] Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. [] 13. Balancing devices provided in accordance with IMC (2006) 603.17 [] 14. Demand control ventilation (DCV) present for high design occupancy areas (>40 pemon/1000 fl2 in spaces >500 fl2) and served by systems with any one of 1) an air-side economizer. 2) automatic modulating control of the outdoor air damper, or 3) a design ouldoor airflow greater than 3000 cfm. Exception(s): [] Systems with heat recovery. [] Multiple-zone systems without DDC of individual zones communicating with a central control panel. [] Systems with a design outdoor atdlow less than 1200 cfm. [] Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. [] 15. Motadzed, automatic shutoff dampers required on exhausl and outdoor air supply openings Exception(s): [] Gravity dampers acceptable in buildings <3 sfodes [] Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are interlocked with fan [] 16.Automatic controls for freeze protection systems present [] 17. Exhaust air heat recovery included for systems 5,000 cfm or greater with more lhan 70% outside air fraction or spec~cally exempted Exception(s): Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the Intemational Mechanical Code prohibits the use of energy reoovery systems. []Systems serving spec. es that are heated and nol cooled to less than 60°F. []Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. []Heating systems in climates with less than 3600 HDD. []Cooling systems in climates with a I percent cooling design wet-bulb temperature less than 64°F. []Systems requiring dehumidification that empfoy energy recovery in series with the c~31ing ceil. [] Laboratory fume hood exhaust systems that have either a variable air volume system capeble of reducing exhaust and makeup air volume to 50 percent or less of design values or, a separate make up air suppiy meeting the following makeup air requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 2°F below room setpoint temperature, c) cooled to co lower than 3°F above room setpelnl temperature, d) no humidification added, e) no simultaneous heating and cooling, Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, speelfications and other celculetions submitted with this permit application, The proposed mechanical systems have been designed to meet the 2{310 New Project Title: 165 Love Lane Report date: 02/08/12 Data fllecame: C:\Users\HOWE\Desktop\LoveLane\Energy regert~LoveLane 2.cck Page 8 of 12 York Energy Conservation Construction Code requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title ~ f ' Signature Date I ' I - Section 6: Post Construction Compliance Statement HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment provided to the owner. F~i HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. E] Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer*Name Signature Date Project Title: 165 Love Lane Report date: 02/08/12 Data fllename: C:\Users\HOWE\Desktop\LoveLane\Energy report~LoveLane 2.cck Page 9 of 12 COMcheck Software Version 3.9.0 Mechanical Requirements Description 2010 New York Energy Conservation Construction Code The following list provides mom detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1: 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90,1 Code and must meet the following minimum efficiency: Central Furnace (Gas): 80.00 % Ec 2. The specified heating and/or ccoting equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency: Split System: 9.50 EER (9.2 IPLV) 3~ Fans with motors > 25 hp may not be equipped with discharge dampers. 4. An integrated air economizer is required for individual cooling systems over 54 kBtu/h in the selected project location and allows simultaneous operation of outdoor-air and mechanical cooling. 5. Cuoling systsm provides a means to retieve excess outdoor air during economizer operation to prevent overpressudzing the building. 6. Cooling systems must nof use hof gas bypass or ofher evaporator pressure control unless the equipment is designed with multiple steps (or continuous) capacity modulation. 7. For cooling systems > 240 kBtu/h, maximum hot gas bypass capacily must be no more than 25% of total cooling capacity. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. All equipment and systems must be sized to be no greater than needed to meet calcolated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. Exception(s): - The equipment andlor system capacity may be greater than calculated loads for stendby purposes. Standby equipment must be automatically controlled to be off when the pdmary equipmeof and/or system is operating. ' Multiple units of the same equipment tybe whose combiced capacities exceed the celculatsd load are allowed if they are provided with controls to sequence operation of th~ units as the toad increases or decreases. 2. Each heating or cooling system serving a singte zone must have its own tempereture control device. 3. Each humidification system must have its own humidity control device. 4. Design heating ecd cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 5. The system or zone control must be a prngremmable thermostet or other automatic control mseting the following critsria: a) capable of setting back temperature to 55°F dudng heating and setting up to 85°F during cooling, b) capable of automatically setting hock or shutting down systems during unoccupied hours using 7 d~ferent day schedules, c) have an accessible 2-hour occupant override, d) have a batte~ back-up capable of maintaining programmed settings for at least 10 hours without power. Exception(s): - A sethock or shutoff control is not required on thermostats that control systems serving areas that operate continuously. - A sethock or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less. 6. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be capable of reducing outduor-air flow to the minimum required leve~s. 7~ Air ducts must be ir~sulatsd to the following levels: a) Supply and return air ducts for conditioned air located in unconditioned spaces (spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics, crawl spaces, unheated basements, and unheated garages. b) Supply and return air ducts and plenum~s must be insulated to a minimum of R-8 when located outside the building. c) When ducts are located within extedor components (e.g., floors or roofs), minimum R-8 insulation is required only between the duct and the building exterior. Exception(s): - Duct insulation is not required on ducts located within equipment, - Duct insulation is not required when the design temperature difference betwsen the intsder and exteodr of the duct or plenum does not exceed 15°F. 8~ Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts fu fans and other air distribution equipment, including multipla-zone terminal units. Project Title: 165 Love Lane Report date: 02/08/12 Date fllename: C:\Users\HOWE~Desklop\LoveLane~Energy reporflLoveLane 2.cck Page 10 of 12 9, All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A and shall be marked '181A-P' for pressure sensitive tape, '181A-M' for mastic or '181A-H' for heat-sensitive tape. Tapes and mastics used to seal flexible air ducts and flexible air connectors shall comply with UL 181B and shall be marked '181B-FX' for pressure-sensitive tape er '181B-M' for mastic. Unlisted duct tape is not permitted as a sealant on any metal ducts. Exception(s): - Continuously welded and locking-type longitudinal joints and seams on ducts operating at static pressurss less than 2 inches w.g pressure classification. 10. Ail pipes serving space..conditioning systams must be insulatsd as follows: Hot water piping for heating systems: I 1/2 in. for pipes <=1 1/2-in, nominal diameter, 2 in, for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 1/2 in, insulation for pipes <=1 1/2-in. nominal diameter I 1/2 in. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1 1/2 in. insulation for pipes <=1 1/2-in. nominal diameter 3 in. insulation for pipes >1 1/2~in, nominal diameter. Exception(s): - Pipe insulation is not reequired for factory-installed piping within HVAC equipment. - Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55OF and 105oF. - Pipe insulation is not required for piping that conveys fluids that have not bsen heatad or cooled through the use of fossil fuels or electric power. - Piping within room fan-coil (with AHRI440 rating) and unit ventilafors (with AHRI840 rating). - Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve and HVAC coil. 11. Operation and maintenance documentation must be provided to the owner that includes at least the following information: a) equipment capacity (input and output) and required maintenance actions b) equipment operation and maintenance manuals c) HVAC system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired or riehl-determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming comments d) complete narrative of how each system is intended to operate, 12. Thermostats controlling both heating and cooling must be capable of maintaining a 5°F deadband (a range of tampereture where no heating or cooling is provided), Exception(s): - Deadband capability is not reduired if the thermostat does not have automatic changeover capability between heating and cooling. - Special occupancy or special apeiicaflons where wide tampereture ranges are not acoeptable and are approved by the authority having jurisdiction. 13, Balancing devices provided in accordance with IMC (2006) 603.17, 14. Demand control ventilation (DCV) required for high design ocoupency areas (>40 parsec/1000 ft.?. in spacas >500 fi,2} and served by systems with any one of 1 ) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor airflow greater than 3000 cfm. Exception(s): - Systems with heat recovery, - Multiple~zone systems without DDC of ladividual zones communicating with a cenlral central paoel. -Systams with a design outdoor a[rttow lass than 1200 cfm, - Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 15. Outdocr air supply and exhaust systems must have motorized dampers that automatically shct when the systems or specss served are not in use. Dampers musl be capable of automatically shutting off during preoccupancy building warm-up, cool-down, and setback, except when ventilation reduces energy costs (e.g., night purge) or when ventilation must be supplied to meet code requirements. Both outdoor air supply and exhaust air dampers must have a maximum leakage rate of 3 cfm~2, at 1,0 in w.g. when tested in accordance with AMCA Standard Excaption(s): - Gravity (non-motorized) dampers are acceptable in buildings less than three stories in height. -Systams with a design outside air intake or exhaual capacity of 300 cfm (140 L/s) or less that are equipped with mctor operated dampers that open and close when the unit is energized and de-eneq3ized, respectively. 16. All freeze protection systems, including self-regulating heat tracing, must include automatic conlrols capable of shutting offthe systamswhen outside air tamperaturos are above40°F orwhen the conditions ofthe protected fluidwill prevent freezing, Snow-and ice-malting systems must include automalic controls capable of shutting off the syslems when th~ pavement temperature is above Project Title: 165 Love Lane Report date: 02/08/12 Data fitsname: C:\Users\HOWE\Desktop\LoveLana\Energy repert\LoveLane 2.cck Page 11 of 12 50°F and no precipitation is telling, and an automatic or manuel control that wilt allow shutoff when the outdoor temperature is above 40°F. 17. Individual fan systoms with a design supply air capacity of 5000 cfm or greater and minimum outaide air supply of 70 percent or greater of the supply air capacity must have an energy recovery system with at least a 50 percent effectiveness. Where cooling with outdoor air is required there is a means to bypass or control the energy recovery system to permit cooling wilh outdoor air. Exception(s): - Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust system.s that tha International Mechanical Code prohibits the use of energy recovery systems. Systems serving spaces that are heated and not cooled to tess than 60°F. Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. Heating systems in climates with less than 3600 HDD. Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. Systems requiting dehumidification that employ energy recovery in sehes with the cooling coil.. Laboratory fume hood exhaust systems that have either a vadable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 2°F below room eatpoint temperature, c) cooled to no lower than 3°F above reom cetpoint temperature, d) no humidification added, e) no simultaneous heating and cooling. Project Title: 165 Love Lane Reperi date: 02/08/12 Data fllename: C:\Ueare\HOWE\Desktop\LoveLane\Energy report\LoveLane 2.cok Page 12 of 12 APPROVED AS NOTED DATE~.p. # ~?~/2.. FEE:?lf''~ f~' ° D BY ~ NOTIFY BUILDING DEPART~'I~T AT 765-1802 8 ~ TO 4 PM~OR THE FOLLO~NG INSPECTIONS: 1 FOUNDATION- TWO REQUIRED FOR POURED CONCRETE 2. ROUGH* FRAMING, PLUMBING STRAPPING ELECTRICAL & CAULKING 3 INSU~TION 4 FINAL- CONSTRUCTION & ELECTRICAL MUST BE COMPL~E FOR C O ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE NOT RES~NSlBLE FOR ~SIGN OR CO~TION ERRORS. ELECTRICAL INSPECTION REQUIRED PLUMBER CERTIFICA T/ON ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY SOLDER USED IN WA TER SUPPLY SYSTEM CANNOT EXCEED 2,/10 OF I% LEAD OCCUPANCYOR USEISUNLAWFUL WITHOUTCERTIFICATE OFOCCUPANCY ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. PLUMBING ALL PLUMBING WASTE & WATER UNES NEED TESTING BEFORE COVERING RETNN STORM WATER RUNOFF PURSUANT TO CHAPTER 2~ OF THE TOWN CODE. FIRE INSPECTION REQUIRED BEFORE OPENING EXTERIOR I LAYER ~" TYPE 'C' EXTERIOR GWB OVER EXISTING SHEATHING AT EXTERIOR WOOD SIDING INTERIOR BI DG DEPI. TOV~N OF SOUTH(ILO 2x6 WOOD STUDS, 16" O.C. FIREBLOCKED 2 LAYERS ~" TYPE X GWB AT INTERIOR NOTE: NAILS TO BE CEMENT COATED, ALL NAILHEADS TO BE COVERED WITH JOINT COMPOUND. ALL GWB JOINTS TO BE COVERED WITH TAPE AND COMPOUND. 2 HOUR FIRE RATED WALL (SOUTH WALL ONLY) ANSI/U.L # 263 165 LOVE LANE 2 HOUR FIRE-RATED WALL DETAIL 1"= 1'-0" STUDIOHOWE 022212 5 SURVEY OF DESCRIBED PROPERTY SITUATE A T MA TTITUCK TOWN OF SOU'I'HOLD SUFFOLK COUNT~, NEW YORK S.C.T.M. DIST. 1000 ~ ~. 141 BLK. 3 0 5 10 15 20 25 30 35 40 SCALE: 1" = 10' DATE: DECEMBER 23, 2011 LOT AREA: 2,533 SQ. FT. = O.058 ACRE 45 CERTIFIED TO: RICHARD PISACANO BROADWAYABSTRACT FIRST AMERICAN TITLE INSURANCE COMPANY JOB NO.: 2011-199 MAP NO.: FILED: REVISIONS: ADD ADDITIONAL CERTS. 1/11/12 LICENSE N0.:050363 HANDS ON SURVEYING 26 SILVER BROOK DRIVE FLANDERS, NEW YORK 11901 TEL: (631)-369-8312 - FAX:(631)-369-8313 MARTIN D. HAND L.S WALKWAY FE8-~-~OI~ 01:09P FROM: T0:1631765950~ P.1 EXTERIOR I LAYER ~' TYPE 'C' EXTERIOR GWB OVER EXISTING SHEATHING AT EXTERIOR WOOD SIDING INTERIOR 2X6 WOOD STUDS, 16" O.C. FIREBLOCKED 2 LAYERS ~" TYPE X GWB AT INTERIOR NOTE NAIG TO BE CEMENT COATED. ALL NAILHEADS TO BE COVERED WITH JOINT C~ND. ALL GWBJOINTS TO BE COVERED ~qTH TAPE AND COMPOUND. 2 HOUR RRE RATED WALL (soum WALL o~.~) ANSI/U.L # 263 165 LOVE LANE 2 HOUR FIRE-RATED WALL DETAIL 1"= 1'-0" STUDIOHOWE 022212 ~i2" HIGH WOOD FOURED-IN-PLACE 8" CONCRETE SLACK GUARDBAIUJ:ENCE /3 ~ CONCRETE STAIR WALL AT STAIR 13'-9" 4'-0" TO CODE LANDING 15 T. @ Il' EXTERIOR NEW CONCRETE STAIR TO LANDING CONCRETE SLAB- BASEMENT CE/VE/~,q/ /VO'ES SLOPETODRAIN 7 42"HIGH I / NBW BATHROOM , A. All work, construct/on cnw mo~er/o/s sho// comply w/th i ~/ WINDOWIN = ~ /~--RELOCATED 165 LOVE LANE EXISTING o. ~_~.,/-" REAR DOOR o// pro,/:si'one of /Vew York Store codes cod w/th other ~ ~, u, OPENING rules, regu/otl'ons one ordl'flonees governl~yg the p/ace of ' BATHROOM~ MATTITUCK the drow/~gs. /t sho// be the respons/D/'l/¢ of the 2003CODE , ,,-~ .... . IS". controctor to ihsto// the work /~ conformonce wtth ~he ~ORG~ARBAR - . . - code cod fo br/ng to the c]t~ent,'on of the Arch,'tect coy DETAILSSEE ~ '- ~-- WINDOW d/screponc~e or conf//~ts betw/een ~he requ/~'emen~s of the s CONCRETE ] SHEETA-S ~.., BATHROOM ' / ~ DOOROPENING code and the drow/ngs before proceed/ns with the work. ]'..0"×~'~"/ ' SOLID FIBERGLASE ~- -- -' ~. £ontractor Zs reepone/b/e for thoroughly exom/~/~g s/te DOOR&F~E cond/~/ons cod c/rchtteeturo/ dra.w/~'/ge pr/or to b/'d cynd stc/rt-=~* ~'~-~ .~---~NEWlNTERIOR ofconstruebbn. ]i' ] i ~ PARTITIONE - WASH ~" GWB OVER IN EXISTING DOOR C. ~-he /~reh/'tect /'~ not respons/'b/e fox ~'ob sofety /~ /'~$ 2xWOODSTUDS OPENING ent, ety, , otud,' g workmen, ox ony other ent,¥y -- STUD IO H OWE '~ 10~ REINFORCED .. ROOM ~. OontrdTctOr~ cho/'ee$ os to ~he /'TTeone of oonetruet/o/'7, STORAGE the sequences of cons~ruetlbn, cod safety preeoutlbns . 10 x20 CONTINUOUS ' i>vc/dent there~o, are not per! of the Archttect's respone~bt//ty. __ i28 MAIN STREET ~ S/~n/~g of controc~ w/7/ be cons~tiered os ev/dence ~ha~ i AMA~ANSETT, NY l l~20 the contractor has stud/ed the requirements cod has m"~NFORC~D SAk~ N~VVWlNDOWS f~7e mermen AZ operat/on, agreed o// A// necessary work to ?-he meet ~ contractor tea~~ d~owi>ygs, be oondtflbns done she~~ end/n of pay ~ obto~b ~horough code off fees, and o// perm/ts end perfect g/wew°rkmon//ke o//ond oohbee,.~~ii ~~' BA~£MENT CO~CR~B BLOCK WALL ~ &COUNTER m~PLAY AS ~QUlRED REBUILD ~ER~OR WALL~ IN EX~STmG OPENINGS .... ~ ~ ~Mo~lud~oho~e.oom 2i2.2~.~00 2i2.2~.0400 V F ~, Con[rec(or [o submit construeD'on schedule, /hsuronce HOUAFIAE~TED cerb'flbotes, end WOl'Vers O/ fl'eR before s~or~ o/ FLOORJOI~ ~O,,,,r,,oi,r,iIFHOLD COAS~FUC~I~. ~ DISP~Y SHELVING TJ1560 ~ 12" O,C notOrch/'teCtscd/e/pdrowlhgs.wn'tlbg of on/ dl~creponc/~s I~ drow/bgs, Do ', ~ ', :}' BACK-upSlGNWlBA~ERY I. De[elYs ore ~tended to show me[hod cod monner of : DISP~Y occomp//~h/~g ~he ~ork. ~/~or mod/f/cobbns me~ be ~ WINDOW WINDOW requ/~ed ~o su/~ ybb d/~ens/bns or cond/bbns cod shaft be ~ ~ ~~ . ~hc/uded ~s port of the ~ork. / · J The dronings cod spec//~ohbns ore ~o be ~oken REBUILDSTORE~gONT ~ FOUNDATIONTO~IN- TO~MAIN-~PAI~ toge~he~ No~eve~ eon t~ems eppeon~g ~ on~ one cod FOUNDATIONA~gEQUIKED :~ ~BUILD~BEQUIR~D ~AEQUI~D S~D~ not $he other ~ sbY/ por~ o/ th/~ con,reeL Should ~here be ~ny d~creponcy be~een the drawings cod the bu$ c/eor~ i~p/l'ed os necessory to complete ~he proj'ec~ = i'-O" i/4" = i'-0" 1/4" = 1'-0" sho// be /~c/uded os /u/~ drown. ~ All rough end ~/~h e/ec~n~e/ work sho// be /~s~//ed ~o meet local crud s~ote code requirements ond sho// be U.L. oppro ~ed. 70.00' - PAOPER~ LINE ' ' NOTES: L. All ~ork to comp~ w/Yh hood/cop cod d/sob/7/~/es .... ~ ~ requirements os pu~ forth b/ not/cool code. ~ ' CONSTRUCTION CONSI~S OF REPAIR& RESTO~TION : ...... ONLY OF EXISTING STRUCTURE M. ~// ~ork ~o be done dun~g normo/ ~ork/~g hours,, DOWNS~UT I Un/eSS o~herw/~e ep~roved or regu/~ed ~ bu/Yd/~g. , PIPEDTO CONCRETEWALKWAY I ~ ' ~ ~ ~ .... ""' 2010 NY STATE PLUMBING CODE TJTLE AND CO'RIGHT PRJ~LEG~ A~ AND SHALL AT ALL TIM~ RE~AIN un/ess o~herw~e spec/f~d. They shall be free of oll , Federal Specl'f/c~flbns, or o~her acceptable stondards. ~ /~ ~x . '~ [ X/ 16~ LOVE ~NE "~ .... '. ALL AESTO~TION WORK COMPLIES WITH NYE SHEET TITLE: O. Shop drow/~gs ~o be subm/t~ed for opprovo/ po'or ~o ~ ~ ~ I ~ ONESTOAYW0OD :~ ~ ~ SECTION I6.09-WlNDLOADSofI~0MPH. , . z , GENE L NOTES ordering cod ~Ns~ol/ebbn. ~ x / ~ - F~ED BUILDING ~ u P. /nvesh~ete stfe deb'very cod s~oroge condthbns ~ ' 8 ......... ~1 ~o~m~ ~ u ~ .......... .,~ FIRE PROTECTION: SITE PLAN, ~l~ /I ~oo~m~ : ~ ~* :' ~ ALL NEW INTERIOR FINISHES TO COMPLY WITH thoroughly. Store motenbls os requ/ked by owner. ~h~ I ~o~,,.<1 .~o.c~--- ~~~' ~. FLOOR PLANS eft moten'o/s zh sx~es ~ppropn~e ~o s/te restn~hbns. ~1 ~m~m~. ~)~n9 .:. """ ~ NY STATE FIRE SAF~ CODE. PROVIDE S~OKE {~)"'~"'m~ ' 3~ _ _ , .... , ................. DETECTORS AS INDICTAED AND FIRE EXTINGUISHERS CONCR~E DR~ELL F O. Nemove ~// debriS, unused equ/~men~ ~nd mo~em~/s. W~ED~.~L~m : ~EEQUIEED h~es. Oon~r~c~or ~o pro~ec~ ~// ~or2 from domoge. ',~~__ NTS VARIES ~, Oom[r~o~or ~o /eove jbb /~ c/e~n cond/hbn. A// 7o.oo'. PEOPEE~LINE moran'o/s, work, cod equipment to be c/ached ~o ~"ADS,PING D~INLINES DATE: sob~/ac(/~n of 02i5i2 S. A// requlked p/umblhg sign-o/rs, chonge orders, punch h~$ /~ems, e~c. ~o be received god opproved by Archi'~ec~ J65 LOVE~NE before h~o/ peymenf. HA~ITUCK, N~ YORK OCCUPANCY ~PE 'M' SHEET NO: Z m// work mo(enb/s cod equl~men~ ~o be guoronteed for ~o S.C.M.T. District: 1000 PEA NYSmte Code-30SF/pp / CONCRETE SLAB- SLOPE TO DRAIN 7 I / SOLID FIBERGLASS DOOR & FRAME BASEMENT STORAGE 10" REINFORCED CONCRETE BLOCK BASEMENT WALL NEW CEDAR SHINGLE NEW FIXED WINDOW IN EXISTING LOCATION NEW SHINGLE ROOF OVER PLYWOOD OVER EXISTING T&G WOOD EXISTING STOREFRONT TO REMAIN - REPAIR AS REQUIRED ~EAST ELEVATION (STREET) 1/4" = 1'-0" NEW SHINGE ROOFING NEW GALVANIZED -- METAL GUTFERS SHINGLE EXTERIOR EXISTING OPENINGS EXISTING DOOR (~ NORTH ELEVATION 1/4" = 1'-0" ~- WOOD FENCE AT STAIR 42" HIGH NEW CEDAR SHINGLE NEW DOOR IN EXISTING WINDOW OPENING NEW FIXED WINDOW IN EXISTING LOCATION~ NEW WINDOW IN EXISTING DOOR OPENING NEff WINDOW IN EXISTING OPENING (~ WEST ELEVATION (REAR YARD) 1/4" = 1'-0" NEff SHINGE ROOFING NEW GALVANIZED [" 42" HIGH WOOD FENCDGUARDRAIL AT BASEMENT STAIR (~ SOUTH ELEVATION 1/4"= 1'-0" NEW WINDOW [N -- EXISTING OPENING REINFORCED CONCRETE LANDING/SLAB- ~ R~BAR 12" O.C, MIN. 8" REINFORCED BLOCK WALL @ STAIR /BASEMENT 42" HIGH 34" ABOVE NOSING CONCRETE BASEMENTSTAIR - 15Treads@ I1" GRADE - SLOPE AWAY FROM BUILDING ~"/FT. MIN, ~ GALVANIZED STEEL GUTrERD DRAIN TO DRYVVELLS CONTINUOUS VENTING REBUILD EXTERIOR WALLS AS REQUIRED SISTER IN 2x6" WOOD STUDS 16' O,C, EXISTING T&G BOARDS TO REMAIN 1/2' PLYWOOD SHEATHING OVER EXISTING BOARDS CEDAR SHINGLES OVER BUILDING PAPER R-19 INSULATION IN WALLS - TYPICAL ~" x 12'' GALV. ANCHOR BOLTS @ 32" O,C, ~. GALV. FLASHING & TERMITE SHIELD 6" FILLED C,M,U, WITH REINFORCING 10" CONCRETE BLOCK WALL WITH VERTICAL ~4 REBAR & HORIZONTAL STEEL REINFORCING WIRE WATERPROOFING MEMBRANE FOOTINGS ON UNDISTURBED SOIL ROOF SHINGLES OVER ROOFING FELT NEW ~" PlYWOOD ROOF EXISTING T&G BOARDS TO REMAIN NEW 3~" x 12" MICROLAM RIDGE BEAM EXISTING ROOF RAFTERS- SISTER NEW 2x10 TO EACH RAFTER R-38 BATT INSULATION ~.~ s~,, GYPSUM WALL BOARD FINISHED INTERIOR - TYP. ~ EXSITING 2x JOISTS @ 24" D.C. - SISTER NEW 2x10 TO BACH JOIST NEW 2x8 HEADERS AT EXISTING WINDOW OPENINGS NOTE: SOUTH WALL TO BE TWO HOUR FIRE RATED - 2 LAYERS ~" TYPE X GWB AT INTERIOR I LAYER s/,,, TYPE C EXTERIOR GWB OVER EXISTING SHBATHING AT EXTERIOR FINISH FLOORING TO BE DECIDED PLYWOOD SUBFLOOR ~ NEW DOUBLE HUNG WINDOWS INSULATED GLASS- PROVIDE FLASHING AS REQ. ALL WINDOWS & DOORS TO HAVE REMOVABLE HURRICANE SHUTrERS- See Detail Sheet A-S 2xE SILL PLATE ~ BOLTED & GLUED REPLACE EXISTING FLOOR JOISTS W/ TJI S60 @ 12`' D.C. R-38RATTINSULATION FOOTINGS- CONTINUOUS (2) #5 REBAR, MIN, 3 ABOVE FOOTING BASE 4 CONCRETE SLAB ON GRADE W/WELDED WIRE MESH REINFORCING ~.~ JOISTS VAPOR BARRIER (~ SEGTION/ELEVATION @$TAIR 1/4" = 1'-0" ~ BUILDING SECTION 1/2" = 1'-0" Alterations to 165 LOVE LANE MATTITUCK NEW YORK STUDIOHOWE architecture 136 MAIN STREET AMAGANSETT, NY 11930 212.366.6400 V 212.366.0400 F info@studiohowe.com R E V I 8 I O N S SHEET TITLE: BUILDING SECTION & EXTERIOR ELEVATIONS SCALE: VARIES DATE: 021512 SHEET NO: A-2 ROOF EXISTING 4"VENT5 FIRST FLOOR 1 1/2" Vent Vent Lay 2" 11/2" Vent II Sink U RELOCATED FIXTURES IN EXISTING BATHROOM BASEMENT C,O. TO EXISTING SANITARY ~) RISER DIAGRAM 3" No. 8 SCREWS 12"O.C. (TYP.) PLYWOOD PLASTIC-COATED PERMANENT WOOD SCREW ANCHORS ' PLYWOOD WASHER (TYP,) No. 8 SCREWS 12" O.C, DETAIL A - TYPICAL ATrACHMENT OF PLYWOOD OPENINGS PROTECTION TO WOOD-FRAME BUILDING Alternate to 120 MPH Certified Window Installation P ood Panel Window and Door Protection for Wood Framed NT$, LIGHT WOOD-FRAME WALL / PLYWOOD OPENINGS PROTECTION; THICKNESS DEPENDS ON WINDOW OPENING WIDTH (I) NOTE: IN LIEU OFSCREWS, LUGS WITH NUTS AND WASHERS MAY BE USED ~ TYPICAL STRUCTURAL DETAILS 36 min 24 miln 1' ~,,,=' 12 mm 51g 305 transfer 12 max 305 39-41 990- 1040 54 r'nin 1370 42 min 1065 ..... Fig. 604.5.t Side Wall Grab Bar for Water Closet ~ BATHROOM GRAB BARS ~" PLYWOOD -- SUBFLOOR- NAIL & GLUE TO JOISTS TJIJOISTS 12" C.C. -- Tim 560- ~" x 14" 'TRUS-JOIST' 'WITH BLOCKING PANELS 100 lb LIVE LOAD 20 LB DEAD LOAD (RETAIL) TJI JOISTS IN COMPLIANCE AND CERTIFIED BY ICC EVALUATION SERVICES ~ FLOOR LOAD DIAGRAM Simpson LSTA30 Ridge Strap al each Rafter R' Beam StraB g Detail il SIMPSON LSTA36 STRAP J MTS30 Rafter Strap at each Rafter Tail T ypical Window and Door Header Detail Each Corner NTS H2A CONNECTOR Simpson H2A Hurricane Ties at each Rafter Tail EXCAVATION NOTES: 1 BACKFILLING SHALL NOT OCCUR UNTIL THE FIRST FLOOR PLATFORM HAS BEEN INSTALLED AND SECURED, Z. ALL BACKFILL MATERIAL SHALL BE FREE OF LARGE BOULDERS ( GREATER THAN 2,5" 3. ALL DRAINAGE TILE AND WASTE PIPING SHALL BE PROPERLY PITCHED AND SUPPORTED ALONG ITS ENTIRE RUN Foundation Notes: The bottoms of all footings are to be Installed a minimum of 3' below grade unless Indicated otherwise. 7. All masonry watis shag be constructed with galv. wall reinforcing, Reln~clng to be heaw-duJy truss4ype, Reinforcing shall be ASTM 615 Grade 60. 6" IPls ta 95% of maximum dry bensdy, Framing Notes: The contractor is to vedfy all measurements in the geld and any discrepancies are ta be brought to the agerdion of the Architect or Engineer p~or to construction, Woad Framing 1, Ail lumber is lo be No. 2 or beUer Douglas Eir Lamb iN) with ~e following minimum specigcteions: Fb = 825 psi Fy =95 psi Fc perp = 625 psi E = 1,600,000 psi 2, AP Laminaled Veneer Lumber is to have the following minimum sbedPcations: Fb = 2,9gO psi Fy = 290 psi Fc perp = 650 psi E = 1,900,0OD psi 3. All beams fabricated wgh mulbple Laminated Veneer Lurcber boards are to be nailed/bolted in accordance wita [ha manutactarePs speciPcagons, 4 Alt straps, connectors, plates, belts, nails, etc. are to be galvanized or stainless steel. Designated c~nnectom, strap etc. on these drawings ara made by Simpson unless indicated othen~ise, AP connectors, straps etc. are to be natied/boged in accordance with the manufacturer's speciPcafions, 5, Alt Poor sheathing is to be 23132 inch AC [yps ply~be, wita an APA span rabeg of 48124. Floor eheaCttng shall be glued and screwed to the tioor joists ( 6" C.C. edges and 12" O.IC, field ). Solid btoCfilng is to be inslaltsd every 8' max or mid span of all tioor Jelsta wita spans exceeding B'. Double jtssta are to be instaltsd below paratiel walls, Blocking is to be instaitsd at all point Icad beadng pOlnta. Walls are to be frameb with 2x§ inch studs spaced 1 g inches O,C, unta~s indicated other,wise, All Joist and beam hangers and tardeners used on the extador are to be Simpson TyI~ 30~, er 316 Stainless Steel. Ail bolts nuts and washers are lo be stainless steel or hot dipped galvanized, Steel 1 -All steel is to be ASTM Specification A-36 2 - All bolted connections are to be trade with A-325 belts. SIMPSON LSTA36 STRAP SIMPSON LTP5 STRAP T ypical Wall and Sill Stra Detail CONNECTION FASTENING.,m LOCATION SIMPSON STRONGTIE i/8' X 6" TITAN HD AT EACH CORNER Wall Corner Connection Detail At Foundation Alterations to 165 LOVE LANE MATTITUCK NEW YORK iTUDIOHOWE architecture 136 MAIN STREET AMAGANSETT, NY 11930 212.366.6400 V 212.366.0400 F info@studiohowe.com ,JlmJ FOR CONSTRUCTION R E V I S I O N S SHEET TITLE: STRUCTURAL DETAILS SCALE: VARIES DATE: 021512 SHEET NO: A-3