HomeMy WebLinkAbout36303-ZTown of Southold Annex
P.O. Box 1179
54375 Main Road
Southold, New York 11971
8/17/2012
CERTIFICATE OF OCCUPANCY
No: 35885
Date: 8/16/2012
THIS CERTIFIES that the building
Location of Property:
SCTM #: 473889
Subdivision:
ACCESSORY GARAGE
830 Clearview Road, Southold, NY 11971,
Sec/Block/Lot: 89.-3-11.5
Filed Map No.
Lot No.
filed in this officed dated
dated 4/6/2011
conforms substantially to the Application for Building Permit heretofore
3/29/2011 pursuant to which Building Permit No. 36303
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
nonhabitable nonheated nonairconditioned accessory two car garage with half bath and storage above as applied for per
ZBA #6440, dated 3/3/11.
The certificate is issued to
Friedman, Joel & Jami
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED 6/20/12
R 10-11-0044 8/6/12
36303 8/14/12
~ Charl~s Sander:
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 36303
Date: 4/6/2011
Permission is hereby granted to:
Friedman, Joel & Jami
6 Cold Spring Hills Road
Huntington, NY 11743
To:
Ad_!.!_~. ~,[L,- _:;'::;;.,~; Detached Assessory Garage (Non-Habitable),
2 car, 2 stories, as applied for.
At premises located at:
830 Clearview Road, Southold, NY 11971
SCTM # 473889
Sec/Block/Lot # 89.-3-11.5
Pursuant to application dated
To expire on !0/5/2012.
Fees:
3/29/2011 and approved by the Building Inspector.
CO - ACCESSORY BUILDING
SINGLE FAMILY DWELLING - ADDITION OR ALTERATION
Total:
$50.00
$746.80
$796.80
Building Inspector
TOWN OF SOUTIIOIA)
BUILDING DEPARTM ICNT
TOWN ItAI,L
765-1802
APPI ~ICATION I:OR CI~'RTII~'ICATE OF ()(GUI>AN(
lhis application must bc 1511cd in I~y ypcwrllcl' or ink allot submitted to the 13~.lilding Depa
A. For new building or new use:
Final survey ol property with accurate location of all buildings, property lines, streets, and nnnsua[ natural or
topographic l~aturcs.
2. final Approval from Ilcallh Dcpt. oC water supply aud sewerage disposal (S-9 lk~rm).
3 Approval ol'elcctrical instnllation l¥om l~oard ol'l:irc Uuderwriters.
Sworll stalcmenl From plumber co,lilting that the solder used iu system comains less than 2/10 of 1% lead.
Commercial building, indnstria[ buildiug, multiple residences and similar buildings and installatious, a certificate
of Code Compliance I¥om architect or engineer responsible for the building.
6. Submit Plauning lgoard Approval of complclcd site plan requirements.
I?~. For existiug buildiugs (prior to April 9, 1957) nou-conformiug uses, or buil(lings aud "pre-existing" land uses:
1. Accurate survey of' property shuwmg all properly lines, streets, building and unusual natural or topographic
2 A properly compleled application and consent to inspect sigued by thc applicant. Ifa CcrlilScalc ol'Occupancy is
denied, the Building Inspcclor shall stale Ibc reasons therefku- in wriling to thc applicatit.
C.
1 Ccrtit]cate of Occul>ancy New dwelling $50.00, Additions to dwclling $50.00, Altcralions t,.> dwelling $50.00,
Swimming pool $50.00. Accessory bnilding $50.00, Additions lo accessory building $5000. I:~usinesses $50.00.
2. Ccrtilicale of£)ccupancy ot~. Pl'C-cxistiug Building - $100.00
3. Copy o['Certiticatc o['Occt.tpancy - $.25
4 tlpda/ed Certificate of()ccupai~cy - $50.00
5 i'cmpolzlry Certilqcatc ol'(>ccttpancy I{csidcnlial $I5.00, Commercial $1500
New Construction: ~ Old or Pre existing BtPlding: (check one)
l louse No. 'Street 1 lamlet
Ownc~ or Owners oF Properly:
Suffolk County Tax Map No 1000, Secliou
Permit No. [)ate of Permit.
Block ,~. Lot //, 5
Applicanl:~
_ _ Underwriters Approval: _
Health Dept. Approval:
Planniug Board ,'\pproval: .............
Reqtlcsl I~)r: Tcntporary Get, ii'cate Final CeNificatc: ___~ (check one)
zkpplicant Signattuc
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971-0959
Telephone (631 ) 765-1802
Fax (631) 765-9502
roger, richert~,town.southold.n¥.us
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Friedman
Address: 830 Clearview Rd City: Southold St: NY Zip: 11971
Building Permit #: 36303 Section: Block: Lot:
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Afton Electrical ContractingLicense No: 42941-me
SITE DETAILS
Office Use Only
Residential ~ Indoor ~ Basement ~ Service Only
Commedcal Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Wall Fixtures Smoke Detectors
Service 3 ph Hot Water GFCI Recpt
Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel NC Blower Range Recpt Fluorescent Fixtun~u Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches Twist Lock Exit Fixtures L_J TVSS
Other Equipment: 2 story garage, 1-combination smoke/co detector, 3-GFCI circuit breakers
Notes:
Inspector Signature:
Date: Aug 14 2012
81-Cert Electrical Compliance Form.xls
P.1
~EB 03 '04 11:~ SOUTHOLD BU1LDIr~ 6~1 765 9502
] ow, H~II, $3095 Main Road
P.O Box llTg
Soulhold. )qcw Yolk ) lgT1-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATION
Fax (631) 765-9502
Tclephone (631) 765 1802
Date:
Building Permit No.
(Please print)
[Please prim)
I certify that the solder used in the water st~pply system contains less thmq 2/I0 of 1%
Icad
Sworn to bei-orc me this 2~ ~Z)
day of 3C°q''-L- · 20 t 2__
(Plumbers Signatme)
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[~/~FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE&CHIMNEY [ ] FIRE SA,-,' ~ ~' INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] RRE RESISTANT PENETRATION
REMARKS: ~/,~/~/~ ~ ~-~
DATE '~'-'~Y- /<~
INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
~.~ [ ]FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] RRE RESISTANT CONSTRUCTION [ ] I:IRE RESISTANT PENETRATION
REMARKS:
DATE
INSPECTOR ~'~ ~
TOWN ~
OF SOU~50.~8DoB2UILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST
] FOUNDATION 2ND
] FRAMING / STRAPPING
] FIREPLACE & CHIMNEY
RISTANT CONSTRUCTION [
ICAL (ROUGH) [
ROUGH PLBG.
INSULATION
FINAL
FIRE SAFETY INSPECTION
FIRE RESISTANT PENETRATION
ELECTRICAL (FINAL)
REMARKS:
DATE
INSPECTOR~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPEC
[ ] FOUNDATION 1ST [1/] ROUGH PLBG.
[ ] FOUNDATION 2ND
[ ] FRAMING / STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] RRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL ~)~OUGH), [ ] ELECTRICAL (FINAL)
REMARKS: ',~ - 'J ~ -
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
FOUNDATION 1ST
FOUNDATION 2ND
[ ],~JGH PLBG.
[ ,~ INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIR~KSAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [/,~FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS: '-~/--~ ~P '~ ~ ~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ] FIRE RESISTANT CONSTRIJCTION [
ROUGH PLBG.
INSULATION
FINAL
FIRE SAFETY INSPECTION
FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (~,OUGH) [ ] ELECTS#GAL (FINAL)
REMARKS: ' ~" / ~ '-~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECT/ION
[ ] FOUNDATION 1ST [,~I:IOUGH PLBG.
] FOUNDATION 2ND
] FRAMING / STRAPPING
] FIREPLACE & CHIMNEY
] INSULATION
] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL~ROUGH) [ ] EL~ECTRICAL (FINAL)
~REMARKS: ~
DATE
INSPECTOR~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECT/ION
[ ] FOUNDATION 1ST [~'~ROUGH PLBG.
[ ]FOUNDATION 2ND [
[ ]FRAMING / STRAPPING [
[ ]FIREPLACE & CHIMNEY [
[ ] FIRE RESISTANT CONSTRUCTION [
ELECTRICAL (ROUGH) [
REMARKS: ~A~ ~r?'-~/~ ~.~.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
] FIRE RESISTANT PENETRATION
] ELECTRICAL (FINAL)
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECT/ION
[ ] FOUNDATION 1ST [~/]"ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ]FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION I ] FIRE RESISTANT PENETRATION
[ ]ELECTRICAL (R~/~U~H) ~,[ ! ELE~CTRICAL ~
REMARKS: ~
DATE ~//~/f~''~ INSPECTOR~~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] ROU~.
[ ] IN~JLATION
[~NAL
[ ] FIRE SAFETY INSPECTION
FOUNDATION 1ST
FOUNDATION 2ND
FRAMING / STRAPPING
FIREPLACE & CHIMNEY
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUG~H) [ ] ELE~CTRICAL (FI ,NAL)
REMARKS: /~×~/,~ x~/~r /~--- ~t~
DATE
INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICA~H) [ ] ELECTRICAL (FINAL)
R EM j R KS: '~'~/?~/.~/.~--~-~ /~t/~ ~//J~
DATE ~:>/~'//Y'-' INSPECTOR ~/~/ {~
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INS~ION
FRAMING/STRAPPING [~rFINAL
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
A
[ ] ELECTRICAL (ROUGH) ~]..ELECTRICAL (FINAL)
REMARKS:
DATE
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net
Examined ~L ...- 4 ,20 II
A. pproved L~ ~- (~ ,20 I[
Expiration / O -- ~- ,20 1~.~
MUST be
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying'?
Board of Health
4 sets of Building Plans
Plmming Board approval
Survey_
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mailto:
Phone:
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date ,20
INSTRUCTIONS
completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced betbre issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department lbr the issuance of a Building Pemlit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building tbr necessary inspections.
(Signature of applicant or name, ifa corporation)
- (Mailing ad'ess of yplicant)' '/
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises <_'ff~O~&
If applicant is a corporation, signature of duly authorized
(Nmne and tit(e ;(2rporate officer)
(As on the tax roll or latest deed)
officer
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
House Number Street
Hamlet
County Tax Map No. 1000~_,Section ~ Block ..~
Subdivision ~"_~>/h~ ,,/~ i~/q'J¢_~C Filed Map No,
Lot //.
Lot
3. Nature of work (check which applicable): New Building
Repair Removal Demolition
4.
5.
State existing use and occupancy of premfi>es~and~intended use and occupancy of proposed construction:
a. Existing use and occupancy
b. Intended use and occupancy
Alteration
Estimated Cost
If dwelling, number of dwelling units ~ '"
If garage, number of cars ~--
Addition
Other Work
Fee
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor -
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
8. Dimensions of entire new construction: Front
Height 2. I '. ~,~/ Number of Stories
9. Size oflot: Front /~,.,¢}¢~' Rear
Dimensions of existing structures, if any: Front Rear _Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front ,/~ Rear
Depth /VA- Height ./~ Number of Stories ~
Rear ~-~/ Depth ,.-~2,
10. Date of Purchase ?_019'7
Depth
Name of Former Owner
ll. Zone or use district in which premises are situated a-HO LOb0 ~)(_/~51Tl~
12. Does proposed construction violate any zoning law, ordinance or regulation? YES ~ NO
13. Will lot be re-graded? YES__ NO X Will excess fill be removed from premises? YES NO
14. Names of Owner o f premi ses~Addres ~Phone No.~l -)) 7z/q- 7~,~7~L~
Name of Architect~-'~/:~/~'T, ~, ~/~/.Address~Phone No ~,~ -~l~O
Name of Contractor I Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES,~ NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES~ NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES__ NO/h~
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY
(Name of individual-signing
cTact) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
being duly sworn deposes and says that (s)he is the applicant
CONNIE D. BUNCH
Nota~J Public, State of Now Yonk
Qualified in Suffolk Count~
Commission Expires April 14, 2
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this h
c~5-~ day of (x~
Notaw Public
Signature of Applicant
TOWN. OF SOUTHOLD
BUILDING DEPARTMENY
TOWN HALL '
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net
Examined ,20
Approved ,20
Disapproved a/c /~f
Expiration ,20__
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mail to:
Phone:
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date ,20
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in builcF~ng for necessary inspections. // ~
Ir~F 'l]]l (Signature of applicant or name, ifa corporation)
Itlll
II Ltl
l, ~- / -'~"-] (Mailing ~address o f~p~lic~nt ) t '
State whether a )l.icant is~0~l~5,,~i{§t~, agent, ~ 'chitect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corpor~at~_signature of duly authorized officer
(Name and title of'corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
L~on of land on_which proposed worj~will be done:
o FZ -,z oJ Mr
House Number Street
Hamlet
County Tax Ma,c;No. 1000 Section /~St'/ BI.~.~O~: . ~., ,,~
Subdivision ~Pr~-.~ ~/°/'tT-~ *°~~'~O
Lot
Lot
11.5'
2. State existing use and occupancy of premises and intended use and occupancy of proposed c'onstmction:
Existing use and occupancy
Intended use and occupancy
3. Nature of work (check which applicable): New Building
Repair Removal Demolition
4. Estimated Cost
5. If dwelling, number of dwelling units PO/OF
If garage, number of cars 2_
Addition Alteration
Other Work
Fee
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor PO/fir
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
Dimensions of existing structures, if any: Front A)/¥ Rear Depth
Height_ Number of Stories
Dimensions of same structure with alterations or additions: Front ./XJP~ Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front ~
Height 2. I i (,, ~ t Number of Stories
9. Size oflot: Front [~,~,~t./' Rear [tq.:31
Rear ,~ 2- Depth
I
Depth /"4 qq. 38'
10. Date of Purchase 20~)~ Name of Former Owner
11. Zone or use district in which premises are situated g
12. Does proposed construction violate any zoning law, ordinance or regulation? YES ~ NO
13. Will lot be re-graded? YES NO ~, Will excess fill be removed from premises? YES NO
14. Names of Owner ofpremises~ ~ZI~D/la0~ Address/-/mrr~aJ~fi~a/2~4 II?'t_.q Phone No.~q/'/~ 7q¥- 75,~
Name of Architectq~l~] ~ .~7~/7/.~ 45'.~. Address~~~t~Phone NotTa313 20/~-~1~
Name of Contractor- ~ - -- ' Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ~ NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet ora tidal wetland? * YES ~' NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES -
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY
~ being duly sworn, deposes and says that (s)he is the applicant
(Name of individual si~ing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Jill M. Doherty, President
James F. I~ng, Vice-President
Dave Bergen
Bob Ghosio, Jr.
John Bredemeyer
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1892
Fax (631) 765-6641
July 15, 2010
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
Jeffrey T. Butler, P.E., P.C.
206 Lincoln St.
Riverhead, NY 11901
RE:
JOEL FRIEDMAN
830 CLEARVlEW RD., SOUTHOLD
SCTM#89-3-11.5
Dear Mr. Butler:
The Board of Trustees reviewed the site plan prepared by Jeffrey T. Butler, P.E., P.C. and
determined the proposed detached garage to be out of the Wetland jurisdiction under Chapter
275 of the Town Wetland Code and Chapter 111 of the Town Code.
Therefore, in accordance with the current Wetlands Code (Chapter 275) and the Coastal
Erosion Hazard Area (Chapter 111 ) no permit is required. Please be advised, however, that no
construction, sedimentation, or disturbance of any kind may take place seaward of the tidal
and/or freshwater wetlands jurisdictional boundary or seaward of the coastal erosion hazard
area as indicated above, or within 100' landward from the top of the bluff and/or wetlands
jurisdictional boundary, without further authorization from the Southold Town Board of Trustees
pursuant to Chapter 275 and/or Chapter 111 of the Town Code. It is your responsibility to
ensure that all necessary best management practices are taken to prevent any sedimentation or
other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands
jurisdiction and Coastal Erosion Hazard Area, which may result from your project.
This determination is not a determination from any other agency.
If you have any further questions, please do not hesitate to call.
Sincerely,
Jill k,~Doherty, PresidentjC/
Boa~! of Trustees
JMD:lms
NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION
· 'Facility DEC ID 1-4738'-00956
PERMIT
Under the Environmental Conservation Law (ECL)
Permittee and Facility Information
Permit Issued To:
JOEL FRIEDMAN
830 CLEARVIEW RD
SOUTHOLD, NY 11971
(631) 208-8850
Facility:
FRIEDMAN PROPERTY
830 CLEARVIEW RDISCTM# 1000-89-3-11.5
SOUTHOLD, NY 11971
Facility Application Contact:
JEFFREY T BUTLER
PO BOX 634
SHOREHAM, NY 11786-0634
(631) 821-8850
Facility Location: in SOUTHOLD in SUFFOLK COUNTY Village: Southold
Facility Principal Reference Point: NYTM-E: 719.066 NYTM-N: 4545.8
Latitude: 41002'02.3'. Longitude: 72023'38.4''
Project Location: 830 Clearview Road - Watercourse - Cedar Beach Harbor/Peconic Bay
Authorized Activity: Selectively cut phragmites in dock area. Remove dead trees in upland area.
Construct a detached garage and driveway. All work must be in accordance with the attached plans
stamped NYSDEC approved on 2/18/11. (LJS)
Permit Authorizations
Tidal Wetlands - Under Article 25
Permit ID 1-4738-00956/00004
New Permit Effective Date: 2/18/2011
Expiration Date: 2/17/2016
NYSDEC Approval
By acceptance of this permit, the permittee agrees that the permit is contingent upon strict
compliance with the ECL, ali applicable regulations, and all conditions included as part of this
permit.
Authorized Signature:
Permit Administrator: LAURA J SCOVAZZO, Deputy Regional Permit Administrator
Address: NYSDEC REGION 1 HEADQUARTERS
SUNY ~ ST~ONY BROOKI50 CIR. CLE RD
STONY B./I~OOK, NY 1 !,~90//-34~~)
Date ;7/~.'.~/~///
Page I of 5
NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION
· 'Faci|fty DEC ID 1-4738'-00956
Distribution List
JEFFREY T BUTLER
Habitat - TW
LAURA J SCOVmZZO
Permit Components
NATURAL RESOURCE PERMIT CONDITIONS
GENERAL CONDITIONS, APPLY TO ALL AUTHORIZED PERMITS
NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS
NATURAL RESOURCE PERMIT CONDITIONS - Apply to the Following
Permits: TIDAL WETLANDS
1. State May Require Site Restoration If upon the expiration or revocation of this permit, the project
hereby authorized has not been completed, the applicant shall, without expense to the State, and to such
extent and in such time and manner as the Department of Environmental Conservation may require,
remove all or any portion of the uncompleted structure or fill and restore the site to its former condition.
No claim shall be made against the State of New York on account of any such removal or alteration.
2. State Not Liable for Damage The State of New York shall in no case be liable for any damage or
injury to the structure or work herein authorized which may be caused by or result from future operations
undertaken by the State for the conservation or improvement of navigation, or for other purposes, and no
claim or right to compensation shall accrue from any such damage.
3. Conformance With Plans All activities authorized by this permit must be in strict conformance
with the approved plans subknitted by the applicant or applicant's agent as part of the permit application.
Such approved plans were prepared by Jeffrey T. Butler last revised 11/22/10 stamped NYSDEC
approved 2/18/11 .
4. State May Order Removal or Alteration of Work If future operations by the State of New York
require an alteration in the position of the structure or work herein authorized, or if, in the opinion of the
Department of Environmental Conservation it shall cause unreasonable obstruction to the free navigation
of said waters or flood flows or endanger the health, safety or welfare of the people of the State, or cause
loss or destruction of the natural resources of the State, the owner may be ordered by the Department to
remove or alter the structural work, obstructions, or hazards caused thereby without expense to the State,
and if, upon the expiration or revocation of this permit, the structure, fill, excavation, or other
modification of the watercourse hereby authorized shall not be completed, the owners, shall, without
expense to the State, and to such extent and in such time and manner as the Department of
Environmental Conservation may require, remove all or any portion of the uncompleted structure or fill
and restore to its former condition the navigable and flood capacity of the watercourse. No claim shall
be made against the State of New York on account of any such removal or alteration.
Page 2 of 5
NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION
· 'Facility DEC ID 1-4738-00956
5. Precautions Against Contamination of Waters All necessary precautions shall be taken to
preclude contamination of any wetland or waterway by suspended solids, sediments, fuels, solvents,
lubricants, epoxy coatings, paints, concrete, leachatc or any other environmentally deleterious materials
associated with the project.
6. Notice of Commencement At least 48 hours prior to commencement of.the project, the permittee
and contractor shall sign and return the top portion of the enclosed notification form certifying that they
are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion
of project, the bottom portion of the form must also be signed and returned, along with photographs of
the completed work.
7. No Construction Debris in Wetland or Adjacent Area Any debris or excess material from
construction of this project shall be completely removed from the adjacent area (upland) and removed to
an approved upland area for disposal. No debris is permitted in wetlands and/or protected buffer areas.
8. Storage of Equipment, Materials The storage of construction equipment and materials shall be
confined within the project work area and/or upland areas greater than 1 O0 linear feet from the tidal
wetland boundary.
9. Activities Consistent with Approved Plans All activities and marsh alterations must be consistent
with the approved plan. Activities or alterations beyond the scope of the approved project and/or not
explicitly authorized by the permit will require further written approval of the Regional Habitat.- TW
office prior to commencement.
10. Driveway/Parking Area of Pervious Material Driveway and parking areas shall be constructed of
NYSDEC-approvcd pervious materials.
11. Phragmites Removal Phragmites removal is limited to selective cutting using hand tools only
(heavy machinery prohibited) to a minimum height of 12" above the root base. No vegetation other than
phragmites shall be disturbed in the authorized area. Cutting shall be performed once annually between
July 15 and August 1 of each calendar year for the life of the permit. Cut shoots shall be completely
removed from the siteand disposed of at an authorized upland facility.
GENERAL CONDITIONS - Apply to ALL Authorized Permits:
i. Facility Inspection by The Department Thc permitted site or facility, including relevant records, is
subject to inspection at reasonable hours and intervals by an authorized representative of the Department
of Environmental Conservation (the Department) to determine whether the permittee is complying with
this permit and the ECL. Such representative may order the work suspended pursuant to ECL 71- 0301
and SAPA 401(3).
The permittee shall provide a person to accompany the Department's representative during an inspection
to the permit area when requested by the Department.
Page 3 of 5
NEW YORK STATE D. EPARTMENT OF ENVIRONMENTAL CONSERVATION
· Facil~ity DEC ID 1-4738-00956
A copy of this permit, including all referenced maps, drawings and special conditions, must be available
for inspection by the Department at all times at the project site or facility. Failure to produce a copy of
the permit upon request by a Department representative is a violation of this permit.
2. Relationship of this Permit to Other Department Orders and Determinations Unless expressly
provided for by the Dcpartmant, issu~ce of this permit does not modify, supersede or rescind any order
or determination previously issued by thc Department or any of the terms, conditions or requirements
contained in such order or determination.
3. Applications For Permit Renewals, Modifications or Transfers The permittee must submit a
separate written application to the Department for permit renewal, modification or transfer of this
permit. Such application must include any forms or supplemental information the Department requires.
Any renewal, modification or transfer granted by the Department must be in writing. Submission of
applications for permit renewal, modification or transfer are to be submitted to:
Regional Permit Administrator
NYSDEC REGION 1 HEADQUARTERS
SUNY @ STONY BROOKI50 CIRCLE RD
STONY BROOK, NY11790 -3409
4. Submission of Renewal Application The permittee must submit a renewal application at least 30
days before permit expiration for the following permit authorizations: Tidal Wetlands.
5. Permit Modifications, Suspensions and Revocations by the Department The Department
reserves the right to modify, suspend or revoke this permit. The grounds for modification, suspension or
revocation include:
a. materially false or inaccurate statements in the permit application or supporting papers;
b. failure by the permittee to comply with any terms or conditions of the permit;
c. exceeding the scope of the project as described in the permit application;
d. newly discovered material information or a material change in environmental conditions, relevant
technology or applicable law or regulations since the issuance of the existing permit;
noncompliance with previously issued permit conditions, orders of the commissioner, any
pr6visions of the Environmental Conservation Law or regulations of the Department related to
the permitted activity.
6. Permit Transfer Permits are transferrable unless specifically prohibited by statute, regulation or
another permit condition. Applications for permit transfer should be submitted prior to actual transfer of
ownership.
Page 4 of $
NEW YORK STATE D. EPARTMENT OF ENVIRONMENTAL CONSERVATION
'Facility DEC ID 1-4738-00956
NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS
Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification
The permittee, excepting state or federal agencies, expressly agrees to indemnify and hold harmless the
Department of Environmental Conservation of the State of New York, its representatives, employees,
and agents ("DEC") for all claims, suits, actions, and damages, to the extent attributable to the
permittee's acts or omissions in connection with the pcrmittce's undertaking of activities in connection
with, or operation and maintenance of, the facility or facilities authorized by the permit whether in
compliance or not in compliance with the terms and conditions of the permit. This indemnification does
not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or
intentional acts or omissions, or to any claims, suits, or actions naming the DEC and arising under
Article 78 of the New York Civil Practice Laws and Rules or any citizen suit or civil rights provision
under federal or state laws.
Item B: Permittee's Contractors to Comply with Permit
The permittee is responsible for informing its independent contractors, employees, agents and assigns of
their responsibility to comply with this permit, including all special conditions while acting as the
permittee's agent with respect to the permitted activities, and such persons shall be subject to the same
sanctions for violations of the Environmental Conservation Law as those prescribed for the permittec.
Item C: Permit'tee Responsible for Obtaining Other Required Permits
The permittee is responsible for obtaining any other permits, approvals, lands, easements and rights-of-
way that may be required to carry out the activities that are authorized by this permit.
Item D: No Right to Trespass or Interfere with Riparian Rights
This permit does not convey to the permittee any right to trespass upon the lands or interfere with the
riparian rights of others in order to perform the permitted work nor does it authorize the impairment of
any rights, title, or interest in real or personal property held or vested in a person not a party to the
permit.
Page 5 of 5
FORM NO. 3
NOTICE OF DISAPPROVAL
DATE: September 20, 2010
TO:
Jeff Butler for
Joel Friedman
P O Box 634
Shoreham, NY 11786
Please take notice that your application dated September 16, 2010
For permit for construction of an accessory garage at
Location of property 830 Clearview Road, Southold, NY
County Tax Map No. 1000 Section 89 Block 3 Lot 11.5
Is returned herewith and disapproved on the fbllowing grounds:
The proposed construction is not permitted pursuant to Art. I1! Sec. 280-15:
In the case of a waterfront parcel, accessory buildings & structures may be located in the
front yard, provided that such buildings.., meet the front yard principal setback.., and the
side yard setback requirements tbr accessory buildings in Section B.
In the R40 zone the principal required front yard setback is 50'.
The proposed garage is setback 12' from the R.O.W.
Also, the construction is not permitted pursuant to 280-15~D.
The dormers are permitted up to 40% of the roof width.
The proposed construction stipulates 46% dormers.
Patricia Conklin, Permit Examiner
BOARD MEMBERS
Lesli~ Kanes Weisman, Chairperson
James Dinizio
Gerard P. Goehringer
George Homing
Ken Schneider
Southold Town Hall
53095 Main Road · RO. Box 1179
Southold, NY 11971-0959
Office Location:
Town Annex/First Floor, Capital One Bank
54375 Main Road (at Youngs Avenue)
Southold, NY 11971
http://southoldtown.northfork.net
ZONING BOARD OF APPEALS
TOWN OF $OUTItOLD
Tel. (631) 765-1809 · Fax (631) 765-9064 ~
IIUi
I//J
~I~ ~0ICANT J el Fn ~,]~/ ~
:o 'edm~ SCTM O00-89-3-11.~n~,xr?~rt.~
PROPERTY LOCATION: 830 Clea~iew Rd.,(adj. to Cedar Beach Harbor), S~~
7
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this
application and determines that this review falls under the Type II category of the State's List of Actions, without
further steps under SEQRA.
SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk
County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its
reply dated Dec. 29, 2010 stating that this application is considered a matter for local determination as there
appears to be no significant county-wide or inter-community impact.
LWRP: This application has been reviewed under Chapter 268, Waterfront Consistency review of the Town of
Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the
information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the
records available to us, it is our recommendation that the proposed action is Exempt from LWRP policy standards
and therefore is CONSISTENT with the LWRP.
PROPERTY FACTS/DESCRIPTION: Subject property is a 52,682 sq. ft. lot with 136.84' on Clearview Rd.,
499.38' on the north property line, 119;31' along Cedar Beach Harbor, and 647.89' on the southern property line.
It is improved with a one and a half story dwelling as shown on the survey dated 2/27/07 by Destin G. Graf, LS.
BASIS OF APPLICATION: Request for Variance from Code Section 280-15 and 15D and the Building
Inspector's September 20, 2010 Notice of Disapproval based on an application for building permit to construct an
accessory garage at; 1) at less than the code required fro.._~nt yard setback of 50 feet, 2) dormers at more than the code
per~m~itted 40% of the roo~ ~ ' -- ~ --
RELIEF REQUESTED: The applicant l~O/pos~s to construct a 747.5 square foot accessory garage in a front yard
having a proposed front yard setback o1[ 12 fe~ where 50 feet is required from the R.O.W. / easement street line.
The appli~xt also proposes to construc~t~me accessory garage having a gable style roof with opposing roof
dormers o4~/o of the width of the gable roofs where a maximum of 40% is permitted by Code.
AMENDED APPLICATION: During the public hearing, the applicant was asked the purpose of the additional
percentage of dormers and they stated it was necessary for the layout of a weight training room. The applicant's
agent was asked to submit the layout of the purportedly necessary weight training equipment on the second floor of
the proposed accessory garage to support the request for the roof dormer variance. The applicant did not submit the
Page 2 - March 3,2011
ZBA File#6440 - Friedman
CTM: 1/)00-89-3-115
Board requested equipment layout, but instead submitted on February 1,2011 an amended proposed plan changing
the gable style roof to a gambrel style roof with proposed roof dormers having 24.6% of the width of the gambrel
style roof thus eliminating the need for a roof dormer variance. There was no amendment to the proposed front
yard setback.
ADDITIONAL INFORMATION: A previous appeal #5886 granted a front yard setback of 13.3 feet from the
ROW / easement street line for a proposed 24 foot by 42 foot (1008 sq. fi.), 1 ½ story attached garage addition.
This current proposed accessory garage is proposed at 12 feet from the ROW which is 1.3 feet closer to the ROW
than what was previously granted for a principal dwelling addition. The subject parcel has ingress and egress via a
50 foot wide ROW which is bisected by the shared property boundary of the adjoining property owner to the north,
thereby creating the 25 foot wide continuous ROW through this subject parcel parallel to its northern property line.
By site inspection, this ROW appears to end at the subject parcel, however the area tax map shows this ROW
continues southwesterly through an adjoining parcel to the south. This continuance of the ROW, indicted by the
area tax map, is not improved for vehicular access and it is heavily treed.
There are no objections to this appeal on file and there were no objections voiced at the public hearing.
FINDINGS OF FACT/REASONS FOR BOARD ACTION:
The Zoning Board of Appeals held a public hearing on this application on January 6, 2011, at which time written
and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property,
and other evidence, the Zoning Board finds the following facts to be true and relevant and makes the following
findings:
1. Town Law §267-b(3)(b)(1). Granting of the requested variance will not produce an undesirable change in the
character of the neighborhood or a detriment to nearby properties. The style and size of the proposed accessory
garage is in keeping with what exists in the neighborhood. The subject parcel has the last dwelling along this
ROW, so there will be no detriment to other users of the ROW.
2. Town Law §267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible
for the applicant to pursue, other than an area variance. The subject property is located on Cedar Beach Harbor and
therefore the conforming location for an accessory structure includes the front yard. The principal dwelling has a
48.3 foot front yard setback from the ROW street line, where 50 feet is required by Code, thus any structure
proposed in this front yard will require at least a front yard setback variance.
3. Town Law §267-b(3)(b)(3). The variance granted herein is substantial. It represents a 76% variance relief, the
proposed accessory garage will require a variance for a front yard setback of 12 feet from the ROW instead of the
required 50 feet. However, this is a private right of way and the placement of the accessory garage will not interfere
with the travel of others.
4. Town Law §267-b(3)ib)(4) No evidence has been submitted to suggest that a variance in this residential
community will have an adverse impact on the physical or environmental conditions in the neighborhood. The rear
yard of the subject parcel contains wetlands and abuts Cedar Beach Harbor. Less environmental impact will occur
by locating the proposed accessory garage in the conforming front yard.
5. Town Law §267-b(3)(b)(5). The difficulty has been self-created. The applicant pumhased the parcel after the
Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the
limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of pumhase.
6. Town Law §267-b. Grant of requested relief for a front yard setback variance is the minimum action necessary
and adequate to enable the applicant to enjoy the benefit of an accessory garage in a front yard, while preserving
and protecting the character of the neighborhood and the health, safety and welfare of the community.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under
New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member Goehringer, and
duly carried, to
Page 3 - Ma~ch 3,2011
ZBA File#6440 Friedman
CTM:.,1000-89-3-11.5
GRANT, the amended application for just the front yard Cack'XO~ariance as applied for, and shown on the Site
Plan/Survey ~p,r, epared by Jeffrey T. Butler, P.E., P.C. dated~2/02/203,O entitled "Site Plan for Friedman Residence,
Bayview, NY Page 1 of I, ar. ad4he~e~_men.4ed~hitectural ~[rawin~ of the proposed accessory garage prepared by
Jeffrey T. Butler, P.E. date~ary 28, 2011 ehgtitled Prop~d Detached Garage" indicating a redesign of roof
style and eliminating the need for a r-~-of dormer~ariance.
1. No central heating or air conditioning shall be installed in the accessory garage "~
~above conditions be written into the Building Inspector's Certificate of Occupancy, whenissued}
_
Any dema'~frm-fr, om. lhe survey, site alan and/or architectural drawings cited in this decision will result~.~d~ and/or a
possible denial by the Building Department of a build/ng permit, and may reqmre a new application and public hearing before
the Zoning Board of Appeals.
Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or
survey site maps, are not authorized under this application when involving nonconformities under the zoning code. This action
does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the
Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action.
The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of
nonconformity.
Vote of the Board: Ayes~ Members Weisman (Chairperson), Dinizio, Goehringer, Schneider, Horn£ng. This Resolution was duly adopted (5-
o;.
4
Leslie Kanes Weisman, Chairperson
Approved for filing ,~ /F~ /2011
/
Town of Southold
I~ Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM
PROPERTY LOCATIOH: S,C,T,M. #: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A
CERTIFIED BY A DESIGN PROFESSION~ IN THE STATE OF NEW YOR~
SCOPEOFWO~ - PROPOS~ CON~U~ON ~ / WO~S~S~ ] Yes No
a. What ~ lhe Total Area of the Pm~ Parcels?
(,ncl~eTotalAr~ofaliPamel~lacatedwithin D~ ~ 1 WillthisProjectRetain~lSto~-WaterRun~
fha Smpe of Wo~ for Proposed Co~tru~ion) ~s.~ / Ams) (This item ~ll include all run.off crea~ by site
b. What is the Total Ama of Land Clearing clearing and/or ~nstruct~n ac~es as welJ ~ all
tS.F.,A~,~ 2 Does the Site Plan and/or Su~ey Show ~1 Propos~
item shall include all Pro~s~ Grade ~nges and
~~ fT~ ~.ff~ ~ 3 Daes~e~itePlanand/°rSu~ey~s~ibe'eemsi°n
~nd sediment con~o~ practices Ihaiw]ll ~ used to~ , ,
~ ~ {~, ~~ ~nfolsite erosion and stem water discharges. This
Excavation where there is a c~nge to the Natural
~ .~ ~',~ , ~ Exlsting Grade Involving moro ~an 200 Cubic Ya~, ~
~~~l~v-'a'~ of Materia{ within any Pardi?
Encompassing an Area in Excess of Five Thou~
(5.000 S.F.) Square Feet of Gmu~ Suite?
6 Is there a NaOmi Water Coume Running through ~e ~ , /
SwPPP's Shall m~l ~e Minimum R~uiremen~ of ~a SPDES ~ral Pem~t 8 Will Driveways. Paring Areas or o~er Im~ious ~ ~/
required, post~nsmcti~ storm water ma~e~n~ pracUms that ~ll be u~d and/or Removal of Vege~flon and/or ~e C~stm~on of any~[ ~ ~
GUNNIE D. BUNCH
STATE OF NEW YO~, ~ /~ · /~ ~*ota~ Pub~. ~e ~ ~w Yo~
~d that hdshc is ~e . ~~ .............................................................................
O~er ~or ~presenmfive of fl~e Om~er or O~ers, ~d is duly aufl~ofized to peflbm~ or have pedbm~ed ~e smd work m~d to
m~e md t~e ~s application; ~at ~1 statements centred in tiffs application ~e ~e to d~e best of ~s h~oMed~ m~d belief; ~md
fl~at fl~e work mil be peffomed in ~e m~ner set foffi~ in ~e applimfion filed hereMfl~.
FORM - 06/t0
Town of Sou
__ thold
Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FOI~NI
PROPERTY LOCATION: S.C.T.M. #:
'~HE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF
STORM'WATERl GRADING, DRAINAGE AND EROSION
CERTIFIED BY A DESIGN PROFESSio~ NEW
Item N urnber: (NOTE: A Check Mark (,~') for each Question Is Required for a Complete Application)
Yes
1
2
3
Will this Project Retain All Storm:Water Run-Off Generated by a Two (2") Inch Rainfall on Sile?
(This item will include ali run-off creeled by sile clearing and/or construction activities as well as all Site
Improvements and the permaneel creation of impervious sur[aoes.)
Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location?
This Item shall include all Proposed Grade Changes and Slopes Controlling Sur[ace WaterFIowJ
Will this Project Require any Land Fil!ing, Grading or E×cavation where there is a change to the Nalural
Existing Grade Involving more than 200 Cubic Yards of Maledal wi[hie any Parcel?
4
Will this Appricalion Require Land Dislurblng Activities Encompassing an A ~a in Ex¢:ess of
Five ~housand (5,000) Square Feel of Ground Surface?
5
6
Is U~ere a Natural Water Course Running through the
Is this Project wilhin the Tlusleesjurisdiclionorwithm On( Hundred (100'! feetofu V/e al~<,rB,~ach;
7
8
9
No
S~IAq IL t )F NEW YOI~K,
tn~ a~d file this applica~on; fl~at all s~temems comained m ii]ia appl~cabon ale t~c to d~e 10est el his knowledge and 1oelief; and
fi]al fite wort( will be pe~fo= reed iu d~e m~ne~ set forth iu fl~e application filed herewid~
Notary
Public:
FORM- 06/07
To~ ~
P.O.
~ ~
BU~ r~ING D~PARTMENT
TOWN OF 8OWI'HOLD
APPLICATION FOR F~ FCTRICAL INSPECTION
JOBSITE INFORMATION:. (*Indicates required infommuon)
*Name:
· a~: ~O C/~r~',e~o- (<o~a ~~o \~ ~,,
· Phone No.:
· ~EjEF DES.C~PT~ON OF WORK (P~e [mm c~a~y) ' ~2
*Is job ready for inspection:
*Do.you need a Temp Cerliflcate:
Temp Inform~ (If-needed]
*Service Size: 1 Pha.e
YESI NO
~ ~r In~edi~ F~m '
Final
BUgLDING PERMIT EXAMINER CHECKLIST *Date Submitted: 3~5~1 Date Reviewed:
Applicant: /~.~ ~ Owner~x ~9~F~
PropertyAddress: ~0 ~ ~ City:~ PreC0s? ~
Building Permits (Open/Expired): Bp ~ -z/C/0 Z- -- , Info:
BP__-Z / C/0 Z-__, Info: BP -Z / C/0 Z- . Info:
Single & Separative Search Required? Y o~/~etermination: - ~
REQ. Lot Siz'~~'e4- 7~/~-) ACT. Lot Size: ~-~
g-
REQ. Front ~ ~ REQ Side "ACT. Side
BP__-Z / C/0 Z-__, Info:
BP__ -Z / C/0 Z-__, Info: __
REQ. Lot Cov. __
REQ. Rear__
ACT: Lot Cov.
PROP. Rear
REQ. Height ACT. Height eT ~ · ~ l~[~. ~,,~ St~$~A CT
Project,~escription: .~ ~ ~ ~~ ~: ~Z ~~
Waterffont~r ~7~ ~ ~. .
Ifyes, waterbody:~~ Panel~ ~ FloodZone:~Bul~ead/BluffD~stance: '
ADDITIONAL APPROVALS ~QUI~D ~;~,cb~~
Suffolk County Heal--yes *Bed~: *Date: / / *Permit~: T
~ - If ao, eertifieatiou required~ ~r N Received: Y or N By:
~S DEC: ~cw~a~r N- Date: ~1~ Permit ~: ~-~7~- ~-~O~a~or~ Lc~t~i ~otes:
SoutholdTrustees: Yo~Date: '~,/:,/0 Permit~: o~~Notes:
SoutholdZBA:~orN-Date: ~ /~/// eermitg: ~ -Notes:
Southold Planning: Y o~- Date: / /__ Permit #:
Town Landmark C of A: Y o~)TE: / /
1~' ,x,,~ ,~.~,~
- Notes:
*NYS CODE Compliance (page 2)/Y)or N
/
Fee Structure:
Foundation: SF
First Floor: ,~ ~c ~- SF
Second Floor: (~ ] t~ SF
Other: SF
Total: ].-.g ~7 SF
Calculation:
13(o7
+ Initial Fee: $ ~--0 0. o O
+ Additiongl Fee ( ): $
SF X $
+ Initial Fee: $
+ Additional Fee ( ): $.
TOTAL: $
NEW YORK STATE CODE COMPLIANCE CHECKLIST
CLIMATIC/GEOGRAPHIC DESIGN CRITERIA:
. Grolmfl Snow Load: 20
Weathering: Severe__ -Frost Depth: 36" __
Design Temp: 11 -. tee Shield Underlay: YES
USE/OCCUPANCY CLASSIFICATION:
· HEIGHT/FIRE AREA: ,
TYPE OF CONSTRUCTION:
DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE
FULL FILAMING DESIGN ELEMENTS: YIN 0
IlEAl)ERS: YfN WALL STUDS: Y/N
CEILING JOISTS: ¥/N FLOOR JOISTS: ¥/N
LUS~IBER SPECIES AND GRADE: YfN
Wind Speed: 120MPH__ Seismic Design Category." B
Termite: M-H Decay:
Flood Hazards:
GLILDERS: YfN
ROOF ILAJ[VTERS:
W1]qDOW A3qD DOOR SCHEDULE: 1)l\
.MISSLE TEST REQUIREMENTS: Y/N
EGRESS 5.'7 S.F.: Y/N
LIGHT 8%: Y/N
VENT 4%: Y/N
NAILING/CONSTRUCTION SCHEDULE: Y/N
MEANS OF EGRESS: Y/N
PLUMBING RISER D[AGILAM: Y/N
LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N
TRUSS DESIGN: YFN
CERTWICATION: Y/N
ENERGY CALCS: Y/N
TOTAL COMPLIENCE?'(Y}/N (RETURN TO PAGE ONE)
RECEIVED
80~,RD OI~ APP~I~
January 31,2011
Vicki Toth, Clerk
Zoning Board of Appeals
Town of Southold
P.O. Box 1179
Southold, NY 11971
Re: Application of Joel and Jami Friedman
Dear Ms. Toth:
Realizing that the Board was concerned about the request that we be given a variance to
exceed the permitted 40 percent dormer area on the proposed garage, we have redesigned
the structure so as to eliminate the need for a variance regarding the dormers. I enclose
herewith seven prints of the new design showing not only the new dormer space to be just
24.6%, but also showing the bathroom enclosed on the first floor as discussed with the
Board at the hearing.
With this submission, I believe our only request is for the variance as to the side yard
down to 12 feet.
FJY:vv
Enclosures
cc: Butler Engineering
Franci~J. Yak~ski
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY 11971 (}959
Telephone (631 ) 765-1802
Fax (631 ) 765-9502
BUILDING DEPARTMENT
TOWN OF SOUTItOLD
STOP WORK ORDER
TO: Joel B & Jami Friedman
6 Cold Spring Hills Road
Huntington, New York 11743
YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK AT:
830 Clearview Road, Southold
TAX MAP NUMBER- 1000-89-3-11.5
Pursuant to Section 144-8A(1) & 280-153 of the Town of Southold, New York,
you are hereby notified to immediately suspend all work and building activities
until this order has been rescinded.
BASIS OF STOP WORK ORDER:
Construction beyond scope of Zoning Board of Appeals decision #6440
dated 3/3/11.
CONDITIONS UNDER WHICH WORK MAY BE RESUMED:
When Zoning Board and Building Department have issued approvals for all
changes.
FAILURE TO REMEDY THE CONDITIONS AFORESAID AND TO COMPLY
WITH THE APPLICABLE PROVISIONS OF LAW MAY CONSTITUTE AN
OFFENSE PUNISHABLE BY FINE, IMPRIS.~NMENT OR BOTH.
G a p//F i s~ /
Building Inspector
IT SHALL BE UNLAWFUL TO REMOVE THIS NOTICE WITHOUT WRITTEN
CONSENT OF THE ISSUING AGENCY.
Jeffrey T. Butler, P.E., P.C.
Architectural and Engineering Services
206 Lincoln Street
Riverhead, NY 11901
Tel: (631) 208-8850
Fax: (631) 727-8033
January 18, 2012
Mr. Gary Fish
Town of Southold
Building Department
RE: Amendment of Permit #36303 (SCTM 1000-89-3-11.5)
Dear Gary,
Attached please fred 4 copies of the floor plan which has been revised to show the as built
conditions as you requested. Please note that the owner added a washer and dryer hook up and a
slop sink on the garage level. They did this due to the persistent flooding of the basement of the
existing house which has mined the existing washer and dryer. Efforts to mitigate this problem
have failed, so they would like to relocate the laundry area to the garage.
Please do not hesitate to call this office with any questions.
~utl.....Enclosures er,
P.E.
BOARD MEMBERS
Leslie Kanes Weisman, Chairperson
James Dinizio Jr.
Gerard P. Goehfnger
George Homing
Ken Schneider
Town Hall Annex, Capital One Building
54375 Route 25 at Youngs Road
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765'1809
Fax (631) 765-9064
http://southoldtown.northfork, net
ZONING BOARD OF APPEALS
MEMORANDUM
TO:
FROM:
RE:
DATE:
Gary Fish, Building Department
Leslie Kanes Weisman, Chairperson/Department Head, ZBA
ZBA decision #6440 Friedman accessory garage
January 26, 2012
Dear Gary,
As per our conversation today regarding the Friedman accessory garage, I reviewed the
plans that were approved in ZBA decision #6440 signed fbr filing by me on 3/7/2011,
and compared them to the amended 1 st floor and 2nd floor plans recently submitted to the
Building Department. Those plans differ in a number of ways from the plans cited in the
ZBA decision and appear to exceed the scope of work authorized by the Zoning Board.
1 will schedule a review by the Board Members on our next Regular Meeting agenda on
February 2, 2012, so that The Board can make a determination as to how to proceed, l
will inform you of the Board's decision immediately thereafter. Meanwhile please infbrm
the property owner and his contractor that work should be stopped until then.
6317274130
04:47:33 p.m. 02-17-2012
FRANCIS J. YAKABO$III
cma~l: francis_.wkabos ki~yahoo.co m
RECEIVED
BOARD OF APPEALS
2/2
February 17, 2012
I"ia I:~ c~i ~ ile: 631 76.5. 9064
Vicki Toth, Clerk
Zoning Board of Appeals
Southold l'own Hall
53095 Maia Road
P.O. Box I 179
Southold, NY 11971-0959
Re: ZBA File #6440~ Joel Friedman
l)car Ms. 'l'ofl~,
I haxc ) our note regarding the hearing lbr the 5'h of April. [ thought my most recent
letter was clear. Wc wanted to go back to our original approved plan so that we could keep on
going. Based on that lhct, 'a,e really don't want to go to another hearing,
Please do get back to me as we would like to resume constraction as soon as possible,
I'JY:jk
BOARD MEMBERS
Leslie Kanes Weisman, Chairperson
James Dinizio, Jr.
Gerard P. Goehringer
George Homing
Ken Schneider
Southold Town Hall
53095 Main Road · P.O. Box 1179
Southold, NY 11971-0959
Office Location:
Town Annex/First Floor, Capital One Bank
54375 Main Road (at Youngs Avenue)
Southold, NY 1 I971
http://southoldtown.northfork.net
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD
Tel. (631) 765-1809 · Fax (631) 765-9064
March 6, 2012
Francis J. Yakaboski
Attorney and Counselor at Law
456 Griffing Avenue
Riverhead, NY 11901
RE: Joel Friedman, ZBA Application #6440
Dear Mr. Yakaboski:
At the Regular Meeting of the Zoning Board of Appeals held on March 1, 2012,
the Board discussed your letter dated February 17, 2012 and stamped received by the
Board of Appeals on February 21, 2012. Since you indicated in that letter that your current
intention is to conform strictly to the architectural plans and conditions and terms approved
by the ZBA in it's Findings and Determination #6440 and signed by me on 3/7/2011, the
Board voted by Resolution to rescind the motion to re-open the hearing on the original
application.
I will send a letter to the Building Department advising them of the motion and your
client's intention to revert back to the original approved plans for the accessory garage. If
you have any questions, please contact our office.
Leslie Kanes Weisman
Chairperson/Department Head
Cc: Melissa Butler, Agent for owner
OWNER AUTHORIZATION
(M~ere the applicant is not the owner)
. o\'dlcr oI:l]lc propert? located al
(Prnpcll~ AddrcsM
located
(Ad&ess)
~,~ ~ ./k,/ Z/~/Lq 2;-~ .2~.?,4. tx, fda5 R lo act on my behalf and take all actions nccessar.,, lbr
/,
and issuance ol'a Variance and Building Permit Ibr the above properl3,.
-J=, ,J'~TTRFT'(5'F' Iq~OPER'I '~ ()WNI{R
CONSENT TO INSPECTION
Owner(s) Name(s)
the undersigned, do(es) hereby state:
That the unders'mned (is) (are) the owner(s) of the premises in the Town of
Soutbold, located at ~2gO ff[~4~l'gffl61/~ ~
which is sb9.kvn and designated on the Suffolk County Tax Map as District I000,
Section ~ ,Block -.3 ,Lot ]/.:~ -
That the undersigned (has) (have) filed, or cause to be filed, an application in the
Southold Town Building Inspector's Office lbr the following: ~]/_dD//~/ff-~
/ ·
That the undersigned do(es) hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon, to conduct such inspections as they may deem necessary with
respect to the aforesaid application, including inspections to determine that said premises
comply with all of the laws, ordinances, rules and regulations of the Town of Southold.
The undersigned, in consenting to such inspections, do(es) so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws, ordinances, rules or
regulations of the Town of Southold,
Dated:
(Signature)
(Print Name)
(Signature)
(Print Name)
BOARD MEMBERS
Leslie Kanes Weisman, Chairperson
James Dinizio, Jr.
Gerard R Goehringer
George Homing
Ken Schneider
Southold Town Hall
53095 Main Road · P.O. Box 1179
Southold, NY 11971-0959
Office Location:
Town Annex/First Floor, Capital One Bank
54375 Main Road (at Youngs Avenue)
Southold, NY 11971
TO:
FROM:
RE:
DATE:
http://southoldtown.northfork.net
ZONING BOARD OF APPEALS
TOWN OF SOUTItOLD
Tel. (631) 765-1809 · Fax (631) 765-9064
MEMORANDUM
Michael Verity, Chief Building Inspector
Gary Fish, Building Inspector
Leslie Weisman, Chairperson/Depath~ent Head 2
Joel Friedman accessory garage, ZBA Application #6440
March 5, 2012
[C: '.: ::OLD
This is to inform you that at the Regular Meeting of the Zoning Board of Appeals on
March 1, 2012, the Board discussed a letter (see attached) dated February 17, 2012 from
Mr Yakaboski, the attorney for Joel Friedman (ZBA Application/Decision # 6440). In
that letter he stated that his client now intends to conform strictly to the architectural
plans and conditions and terms approved by the ZBA in it's Findings and Determination
which was signed by me on 3/7/2011. As a result, the Board voted by Resolution to
rescind the motion to re-open the hearing on the original application. I informed Mr.
Yakaboski that I would send a letter to the Building Department advising you of the
ZBA's motion and his client's ihtention to. revert back to the original approved plans for
the accessory garage. If you have ahy questions, please feel free to contact me or our
Board Assistant Vicki Toth.
Ve~ t~tl.7 .yours,
Leslie Kanes Weisman
Chairperson/Department Head
Jeffrey T. Butler, P.E., P.C.
Architectural and Engineering Services
206 Lincoln Street
Riverhead, NY 11901
Tel: (631) 208-8850
Fax: (631) 727-8033
March 23, 2012
Mr. Pat Conklin
Town of Southold
Building Department
RE: Request to lifl Stop Work Order for Permit #36303 (SCTM 1000-89-3-11.5)
Dear Pat,
In light of the Stop Work Order for the above referenced project, this application was
referred to the Zoning Board of Appeals to consider keeping the half bath on the second floor. The
applicant has decided to go back to the original plan as approved by the ZBA and put the half bath
on the garage level. The attached correspondence from the ZBA indicates that they were going to
communicate this to your department. Please review this letter and my attached plans indicating
the half bath on the garage level and advise me as to when the applicant can proceed with
construction.
Please do not hesitate to call this office with any questions.
Sincerely,
Enclosures
MAR ?_ 3 2012
,:q[ log DE?I
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold. NY 11971 0959
Telephone (631) 765 1802
Fax (63 I) 765-9502
August2,2012
BUILDING DEPARTMENT
TOWN OFSOUTHOLD
Joel & Jami Friedman
6 Cold Spring Hills Rd
Huntington, NY 11743
Re: 830 Clearview Rd, Southold
TO WHOM IT MAY CONCERN:
**NOTE: Final Approval required from Zoning Board of Appeals
Application for Certificate of Occupancy. (Enclosed) '
v'/ Electrical Underwriters Certificate. (contact your electric /
A fee of $50.00. ~
' . ( p rmits involving plumbing after 4/1/84)
__. Trustees Certificate of Compliance. (Town Trustees # 765-1892)
Final Planning Board Approval. (Planning # 765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
BUILDING PERMIT: 36303 - Addition to Single Family Dwelling
Jeffrey T. Butler, P.E., P.C.
Architectural and Engineering Services
206 Lincoln Street
Riverhead, NY 11901
Tel: (631) 208-8850
Fax: (631) 727-8033
August 10, 2012
Mrs. Pat Conklin
Building Department
Town of Southold
P.O. Box 1179
Southold NY 11971
Sll~fi
RE: Building Permit # 36303 (SCTM 1000-89-3-11.5)
Dear Pat,
Enclosed, please find the following documents:
1. 1 Original Board of Health Final Survey
2. 1 Original Solder Certificate
I will forward the Electrical Certificate under separate cover.
Please note that I did speak to the Zoning Board of Appeals to see what will be required to
obtain f'mal approval. They recommended that we first send the final survey to the Building
Departmem for review. Once the Building Department reviews the final survey they will speak to
a member of the Zoning Board.
Please do not hesitate to call this office with any questions.
Sincerely,
Melissa Butler
Enclosures
JOB No. 04-21B
TAX LD, No. 1000-89-03-11.5
ORCHARD LAN~
/
/
SUSJECT LOT 52,682 SQ FT
SUBJEC:r T,O ANY S'TATE OF FACTS
TI{AT AN ACCURATE ABBTRACT
OF TITLE MAY SHOW,
CEDAR BEACH
HARBOR
FILE MAP No. 90 12/20/27
CEDAR BEACH PARK PlO LOT47
SURVEY OF: LOT "D"
MAP OF MINOR SUBDIVISION FOR
ROBERT AND ALDONA NORKUS
BAYVlEW, TOWN OF SOUTHOLD
3ERTIFIED ONLY TO:
CITIMORTGAGE, INC.
BY DESTIN G. GRAF N.Y.S. LIC No. 50067
SUFFOLK COUNTY, NEW YORK
DATE: 02/27/2007 SCALE: 1"=40'
DESTIN G. GRAF
LAND SURVEYOR
P.O. BOX 704
ROCKY POINT, N.Y. 11778
(631) 821-3442
~NE~AL NOTES
I. ORAMIN®D ARE NOT TO BE E/'-,ALED; DIMENC..,IONS TO
eOVERN. PROJECT C, OORPlNATOR DHALL tCE NOTIEIEP
DP ANY PlSCRE-PANCIES.
2. GPEOIAL CARE ~HALL BE TAKEN TO ASSURE MINIMUM
DISRUPTION DP ALL OC,GUPIED PREMISES, EXlSTINe
IMPROVEMENTS AMP UTILITIES.
D. GENERAL CONTRACTOR SHALL PROTECT THE SAFETY
OF THE eENERAL PUBLIC BY EREGTIN¢ ALL REQUIRED
CohLSTRUC.,TION.
5. ALL MATERIALS ARE TO BE NEH AS 5PECIFIEP PER
CONSTRdCTION DOCUMENTS. ANT' ~ED PIX'~)RES OR
b. eENERAL CONTRACTOR SHALL COORPINATE HIS
HOR~ HITH THE INORK Of= ALL OTHER CONTRACTORS,
AND t~UILDIN~ MANAeEMENT.
J. ALL MATERIALS !4ILL BE INDPECTEP AND ALL
DEFECTS AND IRREeULARITIEO IN HA~RIAL5 AND
COLOR MATCHES OR OTHER SPECIAL 5I~ATION5 HHICH
BRO~T TO T~ A~ENTION OF THE PROJECT
COO~I~TOR FO~ APP~VAL PRI~ TO INSTALLATION.
~*. ALL IMANUFAC~JRER~ INSTRUCTIONS 5HALL
FOLLOHED COMPLETELY.
q. R~MOVE ALL PEBRI5 AT END OF EACH HOPJ~ PAT' IN
OP4~ER TO ASDURE A CLEAN AN[;' HELL KEPT
ENVIRONMENT.
IO. PLUMf~IN¢= AN[::) ELECTRICAL CONTRACTORS ARE
RESPONSIBLE FOR SION-OFF FR~OM BUILDIN~
PEPARTi'4ENT UPON COMPLETION DP JOB.
II. ALL PJORK SHALL DE eUARANTEEp FOR A PERIOD DP
DP ONE 'YEAR UNLESS OTH~RHI.~E NOTE[;,. ALL
CONTRACTORS SHALL SUBMIT THIs C-UARANTEE IN
HRITINO HITH REQUEST FOR FINAL PAYMENT,
12. ALL MATERIALB DCED SHALL DE OF FIRE RETARDENT
OUALIT'Y,
D EAINAC::,E
LEAGHIN~ POOL /
2 CAN 6ARAOE
HEIC~HT--21,5'
'M~ 5G. FT.
811
(iht other states)
five boroughs of New York City and Nassau and
DigNet, t -800-2724480 or 811, at least 48 haurs
but no more than t 0 working days (excluding
weekends and legal holidays) pdor to beginning
any me~anized digging or excavation work to
ensure undengmund linea are markad.
Excavators and contractors can also sL~bmlt
locate requests online, through ITIC. If you do not
currently use ITIC, please carl 1~00-524-76D3
for mom InformaNon.
encouraged to call ae well when planning any
type of digging on their pmpeRy. Homeowners
calling 811, the national call before yau dig
personal pmpedy, R is the contmctar'a
raspr~naibility-NOT the homeowner's-to contact
DlgNet. Having utility lines marked pnor to
SITE
~ENEP. AL NOTE5 GONT'D
IE~. OAS, ELECTRIC, SEHEP-,., E'01NER, HATER ANP OTHER
SERVICE CONNECTIONS BHALL BE DISCONNECTEp,
REMOVED OR SEALED IN CO~FORMIT~ Hl~ THE
APPLICABLE RE~LATIONS OF THE PUBLIC UTILIT.Y OR
THE MUNICIPAL AeENC'Y HAVIN¢ JURISDICTION DURIN~
PEMOLITION PHASE.
14. FOLLOH APPLICABLE BTAkDA~;:~ IN POCUMENTB AND
PUBLICATIONS DP THE FOLLOHIN~ AD~OCIATIONB AMP
A'~,ENCIE,S~ NATIONAL FIRE PF~2TEC,TION A~OCIATION
(NFPA), UNDEP4NRITERS LABOR, ATORIES, INC, (~L),
NATIONAL ELECTRICAL MANUEAC'i~RES ASSOCIATION
fi, IRMA), AMERICAN NATIONAL 'STANDARPB INSTITUTE
(ANSI).
INC.
TORh'i IDRAINA®t== GALG..
(Pf~DVIDED FOR PF~DPOSED 2~"X~2.5' D (.;AR ~ARAeE)
VOLUME = AREA x RAINFALL x COEPFICIENT
UDE,
PLAN
LINE / 5¥ME~OL LE®END
PROPERTY LINE
9ETBAOK LINE
PHOTO KEY ~
TEST HOLE
LEAOHIN~ POOL N/OPEN ORATE
EXISTINd~ CONTOUR %
EXICTIN~ 6RAPE x 6.0
ORCHARD LANE
/
//
/// / /
EX. HELL
/
~ POOL
"' / /'
SHELE,'Y S. BLEIFELP
TEST!HOLE DATA
EL, q
I. COLLAR DEF'~ 15 NOT RE~IRED NHEN RA/EABLE i,~TF_J~I~. EXISTS FOR F-~LL PEPTH.
2. COLLAR MA'I~IAL .~HALL BE GLEAN eP. AVEL ~ BAN~ PUN.
TYPICAL STORM HATER
LEACHIN¢ POOL (SD) DETAIl
NOT TO 5GALE
ADJACENT LOT AREA COVERAGE DATA:
ADJACENT LOT AREA =
TL LOT ARE. A - (HETLAHD A~ + AREA BEyoHO ~OO' ~TLAND 0FPCET DOUNDRY)
DD,&2~ 5~.FT. = 52~b~ 5G~.PT. - (17/2~ 50.FT. + I,q72
TOTAL REC-ULATED ADJACENT AREA = D5~2~ CB.PT.
ADJAE, ffi, IT AREA LOT COVERAGE,
EXICT,~ 12-~5.O5 50.FT.
PROPOSED= I,qe5 5~.Fr.
LOT
(F~MALL¥ CARRIe
McDONALp)
AREA OF DEAD
~4~ REHOVAL
(TOTAL AREA = &~MO .~G.FTJ
PROPOSED SITE PLAN:
BITUATE AT,
BA.YVIE~fl, N'Y
TOMN OF 5OUTHOLD
5UPFOLK. COUNT.Y, NEH 'YORK
SC, TM NO.~ IO00-08q-D-p/o II.D
ZONINe DISTRICT, "R-40" REDIPENTIAL LOH-DEhLSlTY, I AC
A~A ~ BITE~ 52,b&8 a.D. (I.21 AOJ
[TO TIE LINE)
AREA OP DHL~ 1,167.~1 S.P. (PT PRNT)
AREA OF SHED: 67,24 S.F.
A~A ~ PROPOSED ~A~E, %4~, B~F.
SITE PLAN BASED ON ORleINAL SURVey BT,
DESTIH ~,. C-RJkF, LAND 'E~RVE'YC, f~
P,O. BOX -/04-
P, (6~1) ~21-B~2
[;,ATE. O2-~, ~E. P' = ~-O"
O~ER~
~O~ ANP ~AHI F~I~HAN
~O~TAL DI~IG?~ ~O~THOLP
~OL ~I~T~I~T~
FIRE DIStriCt, ~UT~LD
ELECTRIC~ ~E~VICE. LIPA
PL~D ZONEJ DEE ~ PLAN ~EHA HAP NO. D&lODCOl~.
~ITE I~ IN G~UND~R H~HENT ZONE
AREA OF
PHRA~MITE MAINTENANCE
'TOTAL A~ = 15,055
/
J
· ~ TIHDER 6ATN/q_K
~ ~ r,LOATING DOCK
CEDAR BEACH
HARBOR
MAP:
ZONING INFORMATION:
RESIDENTIAL LOW-DENSP~' (R-40):
LOT SIZE: 40,000 SQ.FT. (1 AC)
EXISTING,, 52,668 SQ,FT, (1,21 AC)
PROPOSED: N/C
LOT
LOT
WIDTH: 150 FT, MIN
EXISTING: 136,84 FT,
PROPOSED: N/C
DEPTH: 175 FT. MIN
EXISTING; 449,38 FT
PROPOSED: N/C
FRONT YARD SETBACK (PRINCIPLE): 50
EXISTING: 76,9 FT TO PROP. LINE
48,3 FT TO R,O.W,
PROPOSED: N/C
SIDE
YARD SETBACK (PRINCIPLE):
EXISTING: 20,2 FT
PROPOSED: N/C
FT MIN
BOTH
15 FT MIN
SIDE YARDS SETBK=(PRINCIPLE): 35 FT
EXISTING: 42,5 FT
PROPOSED: N/C
REAR YARD SETBACK (PRINCIPLE): 50 FT MIN
EXISTING: ±390.2 FT
PROPOSED:
LOT COVERAGE: 20% MAXIMUM (10,535.6 SQ.FT.)
EXISTING: 2,34A (1,255 SQ,FT,)
PROPOSED: 3.77% (1,985 SQ.FT.)
BUILDING HEIGHT', .35 Fi' MAXIMUM
EXISTING', 22'-0"
PROPOSED: N/C
NUMBER OF STORIES: 2Y2 MAXIMUM
EXISTING: 2 STY (DWLG)
PROPOSED: N/C
MIN
FRONT YARD SETBK (ACCESSORY/WATERFRT): 50'
EXISTING: 103,6 FT (SHED)
PROPOSED: 36.8' TO P.L. (GARAGE)
12,0' TO R,0,W, (GARAGE)
RELIEF REQUESTED
REAR/SIDE YARD SETBACKS (ACCESSORY):
EXISTING: 3,5 FT (SHED)
PROPOSED: 15 FI' (GARAGE)
i BUILDING AREA (ACCESSORY): 750 SQ.FT,
EXISTING: 67,24- SQ,FT, (SHED)
PROPOSED: 748 SQ,FT. (GARAGE)
15' MIN
MAX
BUILDING HEIGHT (ACCESSORY/SLOPING): 22' MAX
EXISTING: 9.0 FT, (SHED)
PROPOSED: 21.5 FT. (GARAGE)
MIN
SITE ~ETLANDS AREA : I-/,O68 SC.PT..
N¥S DEC APPLICATION I.D.: I-4-/~8-OOq56 / 00004
PREVIOUS ZBA APPROVAL: ZBA FILE No. 5886
,SCOPE OF
I. PROPOSED MAINTENANCE OP PHR~eMITES ALON~ CATHALK,
OOC~ ANO ~ITHIN A~A INOIOA~D. THE P~OMlm~ ~ILL ~E
HAND OUT TO A HEI~T OF NOT LE~ ~AN 12" A~ THE
¢~ND. OU~IN~ HILL BE REMO~ P~M ~E A~A BT
HAND AND PROPE~T PlSP~Ep OF. ~,':~' %
JURIDDICTIO~ AR~. '""
T
~- ..
x~~-
.~ ~ <
AGE:
TAX I.D. No. 1000-89-0,3 11.5
JOB No. 04 21UC
SURVEY PURPOSE: UNDER CONSTRUCTION - GARAGE
SURVEY OF: LOT "D"
MAP OF MINOR SUBDIVISION FOR
ROBERT AND ALDONA NORKAS
BAYVIEW, TOWN OF SOUTHOLD
SUFFOLK COUNTY, NEW YORK
suRVEY 0ATE: 05/24/2011 SC^I_E: 1,,=40,
BY Des[in G Graf NYStcLe License No 50067
ORCHARD LANE
202,
e
CEDAR BEACH
HARBOR
DESTIN GRAF PLS., PC
P.O BOX 704
ROCKY POINT, NEW YORK 11778
PHONE [651]-821 5442
TAX I.D. No. 1000-89-05 11 5
JOB No. 04-21UC,
REV 07//22/2012 - WA1ER SERVICE SEPTIC/DRIVEWA~
SURVEY
SURVEY DATE:
e
OF: LOT "D"
MAP OF MINOR SUBDMSION FOR
ROBERT AND ALDONA NORKAS
BAYVIEW, TOWN OF soUTHoLD
SUFFOLK COUNTY, NEW YORK
05/29/2012SCALE:
BY Deshn G Grot N.YS[ote License No. 50067
CEDAR BEACH
HARBOR
DESTIN GRAF PLS, PC
P O. BOX 704
ROCKY POINT, NEW YORK 11776
PHONE [631] 821-5442
NOTES,
TYPICAL STORM HATER
POOL (SD) DETAIl
TOTAL MAXIMUM BEDROOrvIS -' YEARS FROM [
- 5×ISTIN~ /
~ PI~E HTDP. ANT
PPRQV~J.
N/p LAMDDA
A550GIATE6, lNG,
PROPOSED 5TORH
I ' 8'e X 3' DEEP
LEAGHIt~' POOL /
H/BATHROOM ON ~.AB
HEleHT=21.5', 14~ ~X~. PT.
F.P. EL. 112'
TYPICAL S¥OT'EMt
Ii
TYPICAL PLOT LA'f'OUT
& tON6 I~ANP
800-2124 801 811
www dignetnyclL com
By law, excavators and con~"actors working in the ~ive boroughs of NewYerk
City and Nassau and SuffoJk Ceustles on Long Island must contact DIgNet,
1-800-272-4480 or 811, at least 48 hours but no mom than 10 woralng days
(excluding weekends and legal holidays} Odor to beginning any mechanized
digging or excava~Jen work th ensure underground lines am marked. Excavators
and con'mastom can also submit locate requests online, through ITIC. If you do
not currently u~e ITIC, please call 1 -g0D-524-76D3 for more information.
For safety masons, homeowners am strongly en~uraged to c, all as well when
planning any type of digging on their property. Homeowners can contact us
directly et 1-B00-272-4480 or by calling 811, the national call before you dig
number. For excavation work completed on pemonal pmpeAy, it is the
contmcfoCs responsibility-NOT the homeowner's-to c, ontast DigNSt. Having
pROP. OANITARY 0Y0.
IPJ~ I-ICO0 eAL. 5EPTIG TANK
'~-~,'ex4' EFF. DF'TH L.P.
ti ~RADE NITHIN 20'
N/P
SHELE~T S. DLEIPILID
S F LAN
STORM .DRAINAGE CALC:
(pROVII:~I::> POR PI;~OposED 25'x~,25' 5 GAR ~A~5~
VOLUME = A~A x ~INFALL x
A~ = ~ 5.P,
~INPALL
CO~PIGIENT OF RODE = 1.0
VOLUME ~UI~D = 124.q2
(I) ~'~XD~ DEEP LEAOHIN~ P~L5
VOLUME P~VIDE~ = 12~32 GU,PT,
//
°R C//ARD LANE
- PROp I
5ERV TO ~AP~E
I" H'rR
5ERV, TO
48 Hours In Advance,
~ENEp.,AI_ NOTES
pOOL
120
//
LINE / SYMBOL LE®END
PROPERTY LINE
SETBACK LINE
STORM DP~AIN PJPJN® 50
PENCE -~
PHOTO KEY
TEST HOLE
LEACHING POOL w/OPEN ~RATE
EXISTIN® CONTOUR
EXISTIN® 5RADE x 6.0
INLET
HIN 4"<P Af~
PIPE F1Tr.4'I J~" / PT.
20"HIN LI~ER ,'4CE55
0¢'~11~ FOR
MAINTI~JAN~E
ELEVATION
INLET
PLAN VIEH
SEPTIC TANK - IOOO CAI-.,
FINAL ~E
PIF~ PITGH~'/PT,
5' Hill.
LP
~C~LLA~ MATJ~RIAL.~ 5~Tf;~.~TiON)
/~ RATEABLE ~IL
SANITARY LEACHIN~ POOL (LP)
5GALE, N.T.5.
LOCATION HAP..
ADJACENT LOT AREA COVERAGE DATA:
ADJACENT LOT AREA =
TL LOT AREA - (I~TLAND AREA + AREA BEYOND 5OO' HETLAND OFFSET BOUNDRY)
~2~ SC,PT. = 52~6~. 5~,FT. - (l'7.0~g, 5dJ~'~', + I?F/2 5~,FT,)
TOTAL REC:~ULA'r~ ADJACENT ~ = ~2~ SC.FT.
~G~T A~ L~
~ISTI~, 1~55.O5 ~.
~P~, I,~g~ ~.FT. ~.q~)
PROPOSED SI-I- PLAN:
51TUATE
BAYVIEN, NY
TOMN OF c"~DUTHOLD
~UFFOLK. GOUNTT', NEH
5GTM NO., IO00-O~,,~-=J-p/O 11.5
ZONII~ OI~TRIGT~ "R-x~D'' P-.ESIDENTIAL LOH-OENSIT'f, I Afl,
AREA OP 51TE. 52D66 5.E. (I.21 AC,) N/fi,
(TO TIE LINE)
AREA OF [~L~: 1,1~-/.~1 9.P. (ET F:~.NT) N/fi,
AREA OF
AREA OF PP',OPOSED 5ARA~E~ 14g' 5.F.
PHI~NITE MAIN'IENN~E
(TOTAL AREA = 15.O55 SC,PT)
/
/ /
/
ZONING INFORMATION:
R_ESIDENTIAL LOW-DENSITY (R-40):
LO]' SIZE: 40,000 SO.ET, (1 AC)
EXISTING: 52,668 SQ,FT, (1,21 AC)
PROPOSED: N/C
LOT WIDTH: 150 FT, MIN
EXISTING: 136.84 ET,
PROPOSED', N/C
LOT DEPTH: 175 FI', MIN
EXISTING= 449.38 FI'
PROPOSED; N/C
FRONT YARD SETBACK (PRINCIPLE): 50 FT
EXISTING: 76,9 ET TO PROP, LINE
48,5 Fi' TO R,O,W,
PROPOSED: N/C
SIDE YARD SETBACK (PRINCIPLE): 15 FT
EXISTING: 20,2 FI'
PROPOSED,, N/C
UlN
MIN
BOTH SIDE YARDS SETBK
EXISTING: 42,5 FT
PROPOSED: N/C
(PRINCIPLE): 35 FT MIN
RD,R YARD SETBACK (PRINCIPLE):
EXISTING: ±590.2 FT
PROPOSED: N/C
50 FT MIN
LOI COVERAGE: 20% MAXIMUM (10,533,6 SQ,FT,)
EXISTING: 2.34% (1,235 SO.FT.)
PROPOSED: 3.77% '(1,983 SQ,FT,)
BUILDING HEIGHT: 55 ET MAXIMUM
EXISTING: 22'-0"
PROPOSED: N/C
NUMBER OF STORIES: 2,1/2 MAXIMU~
EXISTING: 2 S'P((DWLG) OCT 2 8 2011
PROPOSED'. N/C
BLDG DEPI,
FRONT YARD SETBK (ACCESSORY/WATERFRT): 50'
EXISTING: 103,6 ET (SHED)
PROPOSED: 36.8' TO P,L, (GARAGE)
12,0' TO R,O,W, (GARAGE)
REUEF GRANTED
REAR/SIDE YARD SETBACKS (ACCESSORY):
EXISTING: ,3.5 Fi' (SHED)
PROPOSED,, 15 FI' (GARAGE)
15' MIN
BUILDING AREA (ACCESSORY): 750 SO.FY,
EXISTING: 67,24 SO,FT, (SHED)
PROPOSED: 748 SQ,FT, (GARAGE)
MAX
BUILDING HEIGHT (ACCESSORY/SLOPING): 22'
EXISTING: 9.0 FT, (SHED)
PROPOSED,, 21,5 Fr. (GARAGE)
MAX
MIN
SITE HETLANDS AREA = I-/,0~8 SO.FT.
O'
TOPSOIL ~ ~ ~ C E D A R B E A C HN¥S DEC APPLICATION I.D.: I-4-B8-ooq56 / 00004
Le H A R B 0 R PRI:VIOUS ZBA APPROVAL, ZBA FILE No. 5886
.~,.,, ~ SCOPE OF ~O~K:
~ I. PR,OPOSED HAIN~NCE OF PH~MITE5 ~O~ CAT--K,
D~ AND HI'IN A~A INENOA~D. THE PH~HITE5 MILL BE
HAND COT TO a HEIGHT ~ NOT LES5 THAN 12" a~ THE
-I- ST HOLE DATA
E, ROUND. GUTTING5 HILL DE REMOVED PROM THE AREA BY
HAND AND PROPERLY DISPOSED OP.
2. PF~f:=OSED REMOVAL DP I~EAD TRJ~5 HITHIN TRUSTEE~
JORISENGTIONAL AREA,
5. PP. OPOSE~ 25' X ~2.5' PETAGHED 2 fi,At~ ~'AP./~E INITH
BATHROOM.
4. NP_[,fl ~EPTIG ~¥~TEM FOR C=ARA~E ~4/RE~TROOM,
ENEI AL NOTES 6ENEP. AL NOTES GONT'D O AINA E GALO:
~OVERN. PROJECT C~RPI~TOE 5HA~ BE NOTIPIE~ SERVICE ~ON~GTION5 ~HALL BE DI~ON~TE~, ~ E ~
OF ANT DIGC~PANCIEE. ~MOVED O~ 5E~ED IN CONPORMI~ HITH THE '
DI~ION OF ALL OCCUPIED PREHIEE~, EXIETIN5 DEMOLITION P~DE. -- -- - ~LICABL~
IMPR~EMENT5 AND UTILITIE5. 14. FOLLOH APPLICABLE ~TA~ARD5 IN ~6UHENT5 AND ~ ~ ~ COEFFICIENT OF ~P: I,O
OF T~ DENE~L PUBLIC BY E~CTIN~ ALL RE~I~D A5ENClEE, NATIO~L FI~ F'RO~CTION AD~CIATION ~ VOLUME ~UI~: 124.~2 GU.PT.
COnTRiTION. ~TIO~ ELECTRICAL MA~PA6~5 AE~CIATION 5' MIN. ~ (I) g'~X~' DEEP' LEA~HIN~ POOL~
4. NO MATE~I~ ~BETI~TION ~HALL B~ HALE ~IT~T (AN~I). ~ ~ . VOLUHE ~lpED: 12~.~2
PI~T INPO~MIN~ THE ~61~E~. ~BMIT ~TI~ I ~ - ~ ~ ~ ' I
HATERIAL SPECIFICATION5 AND ~AMPLE~ PO~
CONDTRUOTION DOCUHENT~. ANY ~ED FIX~5 OR ~ ~ ~ ~ ~ ~
AND ~ILDIN¢ MAN~EH~T. t ~ ~ (~TIO~ ~~ ~' ' I~ ~ , z
' LOCATION HAP=
COO~l~rOR FOR APP~VAL PEI~ TO INfiTA~ATION. ( I. ~ ~ I~ ~T m~l~ ~Hm ~em ~RlAL ~I*T* ~o~ ~ mmH. ~JACE~ LOT ~A CO~,~GE DATA: ZON G O TION:
~. HANUPAO~R~ I~UOTION5 ~HALL BE . / 2. ~L~R HA~l~ 5~L BE OLE~ ~L ~ BA~ ~N. RESIDENTIAL L0W-DENSI~ (R-40~:
FOLLO~D COHPLETEL%. / F % L~ ~A - (~T~NO A~ * A~A ~YO~ ~' ~LAND O~ ~DRY) LOT SIZE: 40,000 SQ,~. (1 AC)
q. ~H~E ALL DEBRIS AT ~ DP EACH NOPE DAY IN / ¢ EXISTING: 52,668 SQ,~. (1.21 AC)
O~ER ENVIRONMENT. TO A~EURE A GLEAN AND ~LL ~PT , / / 2 .0, 'LEACHIN¢ ~PIOAL POOL 5TORH (5D) TER DETAIL TOT~ ~2~ ~D ~'~' = 52~¢~ AD~O~T ~ = ~'~' - f11¢¢ 55~2a ~FT. ~.FT.~ + I,q12 ~.FTJ PROPOSED: N/C
IO PLUHD N~ AND ELECTRIO~ OONT~CTOR5 ARE / / ~ ~ NOT TO 5Call AD~T ~ LOT ~VE~, LOT WIDTH: 150 ~, MIN
~SPONSIBLE FOR ~ICN-OFP F~H ~lLPl~ , / /[~ ~ -- ~IETI~, 1~.O5 ~.~. ~) EXISTING: 136,84 ~,
OF ONE YEAR UNLE55 OT~IEE NOTED, ALL ..... .?%~ .,,, _¢.~ /,,o~~ ~ j LOT DEPTH: 175 ~. MIN
OONT~OTOR5 5HALL 5UBHIT THIS ~A~N~E IN AE~l*l:~, ,m~. ~ ~ ~ ~,.~ / ......... EXISTING: 449.38 ~
~ITIN~ ~ITH ~ST ~O~ ~I~L P*~NT.~// - // PROPOSED 5lTL PLAN: , PROPOSED: N/C
~OALl~ / Z% ~ /' %~ .~'*~. / BA~IB, NT FRONT YARD SETBACK (PRINCIPLE): 50
' / ~/ ~ / //; .¢~v~ / TO~NOF ~HOLP EXISTING: 76.9 ~ TO PROP. LINE
/ ~~ ~% ~; / ~ ZONIN~ ~I~T~IOT, "~-~" ~l~"Ab bO~-~E~'~, I AC PROPOSED: i/C
/ ~~/<~%L~1~/ I ~ ~ ~ SIDE YARD S~BACK (PRINCIPLE): 1~
/ /~ ./~,~ % /~:1 ~6. A~A¢51TE, 52~gE.P.(I.21AO) WO EXISTING: 20.2 ~
/ ~ ~ /~%~ . %% k~ ~. (TO TIE Ll~ PROPOSED: N/C
~ ~ '/ ~ A~ ..'. 'h~ .~ ~ ~. ~ ~ a~a ~ DHL~, I,l&~.~l ~.~. ~T P~NT)
% / ~*~~~~ ~ ~ ~.~ ~ m~m~T~mHleH A~ACeH~, ~.245.F. ~ = IBOTH SIDE YARDS S~BK (PRINCIPLE): 35
/ ~. HUBBA~P '
~ .~~ ~_ , NoDDeD) _'~'-I A. PATE,P' (~51)O2_~_~,g21-~2~, I" = ~'-O" PROPOSED:EXISTING: '390.2N/C ~
2n, ~ I ~ :
~ - ~ -~ OH~R, LOT COVERAGE: 20% MAXIMUM (10,533.6 SQ.~.)
/ ~ '~ JOEL AN~ JAHI FRIEDMAN EXISTING: 2,54% (1,255 SQ,~,)
b~ ~ FOeTAL DIE. lOT, 50UTHOLD ~PROPOSED: 5.77% (1,983 SQ.~.)
~ /~ ~P~DA~AOF~AD s FIRE DISTRICT, 5¢T~LD
~ / ~ /~E~H~ ~ ELEC~IC~ SERVICE, lIPA BUILDING HEIGHT: 55 ~ MAXIMUM
~ / (TOT~ A~: ¢~ ~.PfJ ~ ~R SERVICE, ~LL EXISTING: 22'-0"
/ ~ FLOOD ZOO, 5EL ~1~ PLAN (P~HA HAP NO. ~lO~O01~. PROPOSED: N/C
~~ NUMBER OF STORIES: ~ MAXIMUM
EX~STIN6:2 S~ (DWLG)
PROPOSED: N/C
' !~L~LL~~, ~ FRONT YARD S~BK (ACCESSORY/WATERFRT): 50' MIN
EXISTING: 105,6 ~ (SHED)
~P~OP~ED A~ OP PROPOSED: 56.8' TO P.L (GARAGE)
~ /pH~Hl~NAl~E // 12,0' TO R,O,W, (GARAGE)
(TOT~ A~ = 1~5 ~J /// R~lEf REDDENED
' ~ / / R~R/SIDE YARD S~BACKS (ACCESSORY):
EXISTING: 5,5 ~ (SHED)
' / ~1/// ii PROPOSED: 15 n (GARAGE)
~ I/ BUILDING AR~ (ACCESSORY): 750 SQ.~, MAX
/7 EXISTINg: 67,24 SQ,~, (SHED)
ProPOSED: 748 SQ.~. (GARAGE)
BUILDING HEIGHT (ACCESSORY/SLOPING): 22' M~
EXISTING: 9.0 ~. (SHED)
i ~ I ~?TI~BE,~ PROPOSED: 21.5 ~, (GARAGE)
i · ~,l - TIMB~ISTI~6~"* SITE HETLANDS A~EA = l~,O68 S~.FT.
DigNet, 1-DO0-272~4800r811,atleast48hours ..... _ ~ - -'"~ ~*~ NYS DEC APPLICATION I,D.= 1-42~8-OOq56 / 00004
C E D A R B E A C H PREVIOUS ZDA APPROVAL: ZBA FILE No. 5886
~...... 2' ~II/ ' "~ ~ HARBOR
I, ~OPOSEP "AIN~NOE OF "H~eHI~S ALONe CATtLe,
HAND OUT TO A HEI~T OF NOT LEE5 ~AN 12" A~ THE
en~umgedto~llas~li~en plannlngany ~_// DRAWL ~ ~ ~*' CR~NO. O~IN~ MILL BE REMO~D F~H
TAE~LE R402,2
MINIMUM SPECIFIED COMPRESSIVE
~TRENGTI4 OF CONCRETE
MINIMWM 6PECIFIED
COt'iPI~E~JVE 6T~TH
· ~TH~i~N~ POTENTIAL
T~PE O~ LOCATION~ OF
f~IDGE VENT DETAIL
TOP OF SUEr[DeR
TOP OF FOOTINr"
TAtBLE R3OI.4
MINIMUM UNIFORMLY DI~TRItBUTED LOAD5 (P6I)
40
20
40
40
200
All non-engineered [umber to be
32' 6"
i 3' 6" 9' 6" 12' O" 7' 6"
32' 6"
FLOOR
B 5/4" ~U~FLOO~ I~ %, \
,SECTION A-A
FAI
411
PL!JMt~ING f~16Ef~ DIAGf~AH (N'r,5)
UNE×CAYATED
1' 10" 3'4"
2' 8" 10' 4" 10' 4" 2' 4"
32' 6"
FOUNDATION PL__~N
32' 6"
,'[/'
i\,,'
Ii
ATTIC STORAGE/
EXERCISE
8' 0"
X
ROOF PLAN
II-1&-2011 f~EvISION TO PEI~HIT e3~303
PUT HALF 15ATH ~ACK IN PLAN
ENGINEEr:
JEH-t~E'Y T. E~UTLEf~, P.E
PAGE:
2oF4
MINrM~M ~PECIFI~ ~ ........
· ~TWERINN~ p~TENTIAL
TTPE OR LOCATION~ OF ~ --- ~ ~ '
D. CONCR~E 5N~LL BE AIR ~AIN~. TOTAL AIR ~NT~T (P~CENT BT VO~HE OF CONCR~ O O .--~--r-~ ~ ~ ' ~ ~
5HALL NOT BE LES~ THAN 5PERC~TOR ~ORETHAN~P~C~T. ~ ~ ...... b_' ' i u~ ~ ~ ~ ~ , . ~, ,' ,~ : ~ ~, ,
3' 6" 9' 6" ]2' 0" 7' 6" ........
.... Y [0' 3~ 4" 2' 8" ]0' 4" ]0' 4" 2' 4"
32' 6"
MENT DETAIL FEOO PLaN
(0.48 kN/m2) for floor assemblTes, excep~ as fur[her limited by = 2 C~R ~R~ 2X4 eTUDe
2. Fourteen pC (0.67 kN/m2) for ,x(erlor light-frame cold-formedst,,l wallin ~,,TIN~ NOU,,
[XC [P~]ONil Roof/ce"lng dead load, not ,,ceedl,g 25 p.f 0.19 TO, OF ~OTIN~ ..... ~HltE ~NIFl ~ ~ 6ECTION ~'A ~ - Il l: :; [ --
R~IR~T. 2oF4
C~t m~oN 1-19-2Oil REVI6ION TO PER~IT e3~305
TABLE R402,2
MINIMUM ~PECIFIED COMPRESSIVE
STRENGTH OF CONCRETE
MINrML~M
UJEATNERINN.~ POTENTIAL
TYPE OR LOCATION~ OF
CONCRETE STRUCTURE6 NE~I~IB~ MOD~ATE 6EYRE
TABLE
M[NIMLIM 5PEC;IFIED C. OMPRE6,%I%'E
FIINIPP iN 1SPECIFIED
COMP~E~I'VE 6T~B4&TH
IHEATHERINN& POTENTIAL
TYPE OR LOC:;ATIONE~ OF
f~IDOE V'ENT DETAIL
{0.48 kN/m2) for floor assemblies, excep~ as furEher [ImTfed by
2, FeurEeen pal (0.67 kN/m2) for exterior lighE-fr~me cold-formed
5, Ten per (0.48 kN/m2) far InEerTor Jlght-frame wood w~ll~.
TABLE R501.4
MINIMUM UNIFORMLY' DISTRIBUTED
J
32' 6"
i 3' 6" 9' 6" 12' 0" 7' 6"
32' 6"
FLOOR PLAN
.SECTION A-A
PLUMEHN~ RI6ER DIA&RAM (NTS)
UNEXCA',/ATEID
FOUNDATION PLAN
32' 6"
ATTIC
EXEf~CI6E
32' 6"
ROOF PLAN
MAR 2 3 2012
BI DG DEPT.
L__ fow~ OF SOUTHOLD
11-1~,-2011 f~EVI,~ION TO PERMIT
1-19-2011 F~E'VIE;,ION TO PERHIT e3~,3,O3,
3-1D-2Oll t~EvISION TO PERMIT #3~303
PA E:
2or4
I
MINIMUM ~PECI;IED
~T~N~TH O~ CONCreTE [ ........
MINIMUM ePECIFI~
r .... ..............................................................................................
TTPE O~ LOC~TION~ OF ~,~, ~ ,
FO~ 61, I pOUND P~ ~QUA~E IN~ · ~.~5 KPA. ~~_ ~ CLG N~T ~'2" O~ 6LA~ , .[ ~ ~ PITCH TO O,H.D. ~ ~PO~ ~T ~ADE ~ '
DU~ING CON~UCTION 6HALL BE AIR-~TRAIN~ CONCRETE IN AC~RDANCE ~Th ~O~OTE D. : = ~ ~ ~ ~ ~ ~ ,'~ [ ~ ~.,
3' 6" 9' 6" 12' O" 7' 6"
FLO0 PLAN FOUNDATION PLAN
coN~ ~ ~/ 8' 0" i ?' ]0" ~ ~ ~ '"
~s ................................................................
5, Ten psf (0,48 kN/m2) for [.Jar[or light-frame wood w.lla, 4II p~ ~NC. ~B- 30~ P.¢,L ; ................................................ ~ .............
, -
, ................. . 4. v~ 32' 6"
TABLE ~OL4 ~¢N~I OOF PLAN
MINIM~ ~NIFO~MLY DI~T~IBUT~ LO~D$ (P~I)
~E LIVE LOAD ' :
8TAil8 40
Jail non-e.ginaered lumber [o be ~
~[a~ ~]~ CO~CT[O~ I 1-19-2OH REVISION TO P~MIT
~E~UIR~T~ CAST IRON
~E ~AP ~U~MIT A~ ~UlLT HA~ ~ATH ~YOaT
PLUMBING RISE DIAGRAM (NTS)
MINIMUM SPECIFIED COMPRE581VE
~TI~ENGTH OF CONCreTE
MINIMUM ~PECIFI~
COMP~E6iVE ~GTH
~THE~INN~
TYPE OR LOCATION~ OF
DE61~N
CRITERIA:
60IL BEA~IN~ CAPACIT~ FO~ Till6 6lTL ~ D~AIL ~H~ ~R ~INDI6UDJECT TO DAMAGE
I~ ~ED ON TE~T HOEE~ ~ OTHER~ CERTIFICATION OF ~l~ ~ CONN~CTION ~OU~ , ea~[c F~OeT
2,000 PSI (~,~P) PER TABLE R401.4.1 REQUIRED. LO~D (MPH) :AT.CRT :CATA~ORT ~EATH~IN~ DEPTH T~MI~ DECA~ T~P I~ ~UI~ HAZARDS LOAD LOAD ~UCTION LOAD CLarIFICATION
OF THE 200~ ~ESIDENTI~L CODE ~p~ pROTECTION ~T 4b p,~ 120 ~ I C ~E~E 3~" ~OD~ATE 6LlaHT TO ~0~
OF NE~ TORK STATE ELECTRICAL ~su~N~ TO ~eo~.~.4,
FA~TENIN~ ~H~WI F ON
INSPECTION REQUIRED ~A~ e~ ~ T~ ~
T~LE R301.5 2010 N~ ~OR~ ~TATE CO~E:
COMPLY WITH ALL CODES OF ~NIMUM UNIFORMLT DIS~I~UT~ LOAD~ (P~I) T~ plane h~e been ~r~n Iff e~e mith
APPROVED AS NOTED NEW YORK STATE & TOWN CODES =om Re.ldemlal Coda or New ~ e~ ~
pATE~B P ,3~3 °~ AS R~D AND CONDITIONS OF u,s LrV~ ~o~ ~-'.'.t~ ~a ,h. ~o~n or
~OTiFY BUILDING DEPAR~E~ AT SOUTHOLD TOWN P~NNING BOAR0 PAS~EN~ ~EHICLE 5A~a~ ~O TABLE
765-1802 8 AM TO 4 PM FOR THE ~ ,, SOU~0LDTOWNTRUSTEES Awmc~ ~ITH 5TO.AGE 20 ALLO~A~LE D~LECTION OF
1 FOUNDAT(ON - TWO REQUIRED N,Y,S. DEC ~o0~ OTN~ THAN ~IN~ ~00~ ~ ~T~UCTUAL
~oR POURED CONCRE~ ~ STA~ ~ ~TRUCTUAL ~E~B~
2 R dGH- FRAMING, PLUMBING, ~ARD~i~ AND HANDRAIL~ 200
S~RAPPING, ELECTRICAL ~ CAULKING PROPOSED ~OOF DOR~ ~ATIO~ __ D~LECTION
4 FINAL- CONSTRUCTION & E~C~ICALPLUMBING~/32.5 =.24~ (24.&%) TABLE R3OL~ ~,~ ~ n~ ~m~,~ ,w~ .o ,~
MUST BE COMPETE F~ C,O. A~[~MBING W~TE ~AX ALEO~ED P~ 2~0-15~ = ~0~~
ALLCONSTRUCTION~L~ &WA~R~6~EED, ~INIMU~ ~OOF LI~E LOAD6 IN POUND6-FORCE ~,~,.rm=~
REOUIREMENTS OF THE C~ES OF NEW TEeING'DEFOE ~RING PER 6QUARE FOOT OF HOrIZONTaL P~OJECTION .~o~ .~ .~m c.mu.~
YORK STATE. NOT ~NS~LE F~ 3 ~' ~ ~I~UTA.y
DESIGN OR CON~TI~ E~S. 4~ rN S~4,E ~ ~ OT,~ ~ ,~ ~0
~ ~ ~0" 7' 10" 4' 0" ~' 4". ~0 =,~ 0~.
HAS BEE~AP~ .,~.. ,~ .~ ~ ,,.~ ~o ~ ~...
PURSUANT TO CHAPTER 230 ' lint2 J Ami non-engineered lumber to be Douglae Fir ~2 0r better
OF THE TOWN CODE, o~s
ONL~DCON~NTBEFOI ~ ..... ~,,~o~=~=4~,0~=)~==~=. ~RR30 .2.2. De~d Dada for wa,~ =boy. grade ~h,JI not exceed:
C¢RTIF~OF~OUPA~~ ~~o~:~.~o~.~.~0~,~1. Rfteen psi (0.72 kN/m2) for exterior I[eh~-fmm= wood
E~EED~fOOF I%~L ~ ~t T~n psf (0.48 kN/m2) far ~nterlor light-frame ~ood woH,.
OCCUPANCY OR --- ., 5. Eigh[y ps¢ (~.~3 kNit2)'.r 8-,.c,-~h[ck (205 ~m)
WITHOUT
CERTIFICATE
OFOCCUPANCY ~mL--m~.we bracing amounts In Ch.pier R6 ere ,ncre.sed ,.
' , woo.
,, , ', ,,
', ' ' , '. : FOR WALL OPENING PROTECTION 0F120 MPH 3-SECOND WIND GUSTS
' '. ' ( M~IMUM MEAN ROOF HEIGHT: 35')
r. ................................................................................................. I ............................................................................
,
F~ONT ELEVATION ~IONT 61DE EKEVATION SHUTTER ASSEMBLY
, ,
' MACHINE BOLT ~ 12' O.C, / ~ ~ ~ , I
-=- --
~ 19 19 ULTIP~ 6ECTION
_ _ ', ,, ,,
SHUTTERASSEMBLY ~ ', , ~ h ,
~m mm mm ,
REA~ ELEVATION LEFT 61DE ELEVATION ~ACHINE ~OLT - 12'
WlN~ SWBQ~CT TO ~AMA~E P~O~
TABLE ~40~.~
MINIMUM SPECI;IED ~OMPt~E~$1V'E 32' 6"
COMPRE6I~E 6~TH ~'C)
· ~TWERINNG P~TENTIAL
~T ~ALLe, FOUND~TIONe AND OTH~ CONCeal NOT 2,~ 2~OO
A. AT ~ Pst, ,
-~ .... ~ , , , ,
: I
__
,,
' ' ' L' 10" 3' 4" 2' 8" 10' 4" ~, . , 10' 4"
32' 6"
TO~
EXCEPTION= Roof/ceiling dead loads not exceeding 25 psi (1.19 TOP
A=IC6 ~IT~ .TORA~E 20
TAESLE 1~402.2
MINIMUM Sf::'ECIf:IED COMP~EE;$1VE
STRENGTH OF CONCRETE
MINIMUM 6F>EC. IFIED
COMPRE61¥E 6Tf~ENGrTH
UJE~TNEI~INNG POTENTIAL
T¥~E 01~ LO~;ATION6 O{=
CONCt;~ETE E;,Tf~:UCTUI~EE; N~LI~-1tBLE MODER!ATE ~,EvEf~E
BA6Et-1ENT ~ALL6, FOUNDATIONe AND OTN~ CONtROl NOT 2,~ 2~00
~. ~. ~.'~°8
........................ !\ /I .................... [\ /t ....... ~'~ .............
I~/ ~/I ~
~---- ~-~ t J + ----~-
,~ 1, ,~-~- .
I /I'% II I /'"k ~ ~
........................ ,. . ........................ ............. .......
~'o'~ x e.~.. ~8'o"
FOUNDATION CLEAR~ANCE F~OM ~,LOPE$
, ~ ' ~ GABLE ENd,ALL
O~T~/DE CO~N~
~E LOCAT~ IN T~E ~A~E ~ ~- ~ NA{~ ~A~ ON
~o,,~,~,m TOP PLATE FR~MINO TO ACCOMMODATE PIPINO ~ ~,a,~**..o.~.
NO CEILING ~C~T~ ~ ~L~KIN~
NOTCNIN~ AND BORED HOLE LIMITATION5 ~'~"""~" ~
~OWOH P~TE ~ NOTCHINa PROVI~ION~
LOCA~ IN ~IDDLE ~NE-THIRD ~ILL PLA~ ~ --
BO~ NOL~ ~HALL NOT/ TBD D~TH. TH~ 6~ ~T BE z FOUNdATiON ~ -=~ ---~---T~--- ~-- AT BO~O~ OF ~ 6T~ IN
DOUBLE ~ND NO HOR~ T~A~ ~o ,, ~,, UPLm~ ~ ADDITmON TO CONNECTOm AT
NOTCHINO AND BORED HOLE LIMITATION~ PL~OEM ~MIN~ INT~M~IATE
FO~ EXTERIO~ DALL5 AND BEARING DALLSTTPICAL DALL,FLOOR AND ROOFF~AMING~o.~,.~ L~ T.AN . ~2, U~ D~P ~/~ IO~ NAIL~ IN ~D ~"D 4,0~ .AIL. IN PLATE
(DFCM 2OOI 5BC HIGH DIND EDITION) TTPICAL FRAMIN~ AND UPLIFT FIGURE R30~.2
CONNECTION5 FOR OPENINGS MINIMUM FIXTURE
120 MILE PER HOUR ZONE - NAILIN 6C;WEDLILE
(TAtSLE 3.1, UJFCM NK'-H [UIND EDITION)
JOINT DESCRIPTION I NUMBER OF NAILS I NAIL SP4,CING
ROOF FRAMING
JO~T h~P~ OV~ P~TITION~ ~A~H-NAIL~) ~-I~ ~h LAP
TIE TO ~AF~ (F~E-NAIL~) ~ P~ TIE
BLOC~IN~ TO ~FT~ ~OE-NAIL~)
·ALL ~MIN~
FLOOR
ROOF ~HEATNIN~
OEIMN~ ~N~TNIN~
F~ ~H~TNIN~
(TABLE 3,11 mFCM NIGH UJIND EDITION.)
[/JALL SHEATHING ATTACHMENT REQUIREMENTS FOR mIND LOADS
(110 MPH ~-E}ECOND GUST · ~O MPN FASTEST-MILE U. IIN~ Spm~'r'~ {PER TAISLE
SHEATHING LOCATION STUD SPACING STRUCTURAL SHEATHING MAXIMUM NAIL SPACING
(~EE HOTE D (INCHES, O.C.) OR PANEL SIDING FOR ~,d COMMON NAILS
(SEE HOTE 5) (INCH., P.O.)
("TABLE 3.2B [UFCM NIGH IUIND ED[TION-2OO1)
SILL Ot~ BOTTOM PLATE TO FOUNDATION ANCHOR BOLT CONNECTIONS RESISTING LATERAL 4 SHEAR LOADS
MAXIMUM ANCHOR MAXIMUM ANCHOR
5oTroM PLATE TO FOUNDATION FOUNDATION
BOLT 6PACING (IN.) BOLT ~PACING (IN,.)
BOLT CONNECTION RE$I&TIN~ 6UP~'ORTrN~ (1/2" ANCHOR ~OLT~) (5/~" ANCHOR ~OLT~)
'fha design of this structure Is based upon the presc~pflve approach using the
Wood Frame Construction Manual, High Wind Edition (WFCM) published by The Amedcan Forest
and Paper Association, (2001)
Non-structural elements are based upon The New York State Residential Code- 2010 Edition
For the Climatic and Geographical Design Criteria, see Table R3Of .2(1 ) on cover sheet.
All non-engineered lumber to be Douglas Fir #2 or beifer
Wind Umitstions-Seciton R301.2.1
Design Criteria-Section R301.2.1.1 (See Table R301,2,1.2 f~r Wind-Borne Debris Protection
Fastening Schedule For Wood Structural Panels)
Dead Load-Section R30t .4
Live Load-Section R301.5
Light and Vectllstlon-Sestlon R303
Minimum Room Areas-Section R304
Ceiling Height-Section R305
Santiation-Sectlon R306
Toilet Path and Shower Spaces-Section R307
Glazing-Sestlon R308
Garages and Carports-Section R309
Emergency Escape and Rescue Obenings-Seaiton R310
Ex..Section R311
Stelrwayp-Sectlon R3t 1.5
Handrails-Section R311.5.6
Guards-Section R312
Smoke Alarms-Sect[on R313
Foam Plastic-Section R314
Flame Spread and Smoke-Section R315
Insulation-Section R315
Dwelling Unit Seberefion~ecfion R317
Matalure Vapor Retarders-Section R318
Pmtocfion Alt alnst Decay-Section R319
Pretectbn Against Termitss-Sectlon R320
Site Address-Seciton R321
Accessibility-Section R322
Flood Reslstaat Constrdctlon-Sectlon R323
Foundafions-Chapter 4
Design based upon presump5ve load bearing values of sandy gravel and/or gravel at 3000 pounds
per square fool Contractor to consult Enitineer if different soil materials are found upon excavation,
or test hole, far alternative faoting and foundation wall deslitn,
5~8" Anchor Bolts (SSTB 28) See chart on this sheet for spacing
30" x 30" x 1Z' deep poured concrete colurnn foofings, 3000~ test
All foofings to be carried down to undisturbed soil
by the beckflll (Section R404,1.7)
Floom-WFCM Prescriptive Method
Floor framing shall be nailed in accordance with Table 3.1 WFCM HIGH WIND EDITION
greif ste pplng-Sectlon R502.t2
Fireblocldng-Sestion R502,13
Floor Construction:
%" PGe plywood subfloor, fasten per Tabta 3.1 WFCM
Floor joists:See Foundation and Floor Plans, spacing as noted
Fasten per Table 3.1 WFCM
2-2x6 ACQ sill with copper termite shield and sill seal
Finish floors per agreement
Wall Constructlon-WFCM Prescriptive Method
Wall framing and finishing shall be nailed and or screwed in accordance with
Tbele 3,1 WFCM
lx6 Pine tsscla, wrap
Overhangs as noted
Vinyl vented sctflts
Aluminum gutters and leaders
Siding:See Elevations
Tyvek housewrap
~' OSB sbeathlng, see fastsnlng schedule, Table 3.1 WFCM
2x6 EVLuda ~ 15" o.o~ with 2x6 shes and doubta 2x6 ptats
%" Gypsum wail board
5/8" Type X GWB in garage
%" MR GWS In wet areas
At least one window In each sleeping room shell comply with the exit reqalrements of section R310
Note drilling and notching Ilmltetions In figure R602.6(1 ) for beating walls
and figure R602.6(2) for non-bearing walls.
Follow extedor comer framing detell fiiture R602.10.S
Roof .Assemblies- WFCM Prescriptive Method
AnphaR atdp shingles shall have a minimum of six(6) faatenere per shingle (section R905.6)
Undetiayment application (Sect[on R905.2.7)
For roof slopes of two(2) units vertical in Iwalve(f 2) units horizontal ( 17-perceat slope),
up to faur(4} units vedlcal in twalve(l 2) units horizontal (33-perceat slope), underlayment
shall be hvo(2) layers applied In the foltswIng manner. Apply a 19-Inch (483 mm) strip of
undedayment felt parallel with and starting at the eaves, tsstened sufficrenity to hold in place.
StaKing at the cave, apply 36-Inch-wide (914 mm) sheets of underlayment, overlapping
successive sheets 19 Inches (483 mm). and fastened sufficiently TO hold In place.
For roof slopes of tour(4) units vertical In N,'alve(12) units
Ice Protection (Section R 995.2.7,1 )
Underlayment In Hiith wind (Section R 905,2.7.2)
Flashing (Section R 905.2.8)
Chimney's and Firesodcas-Chaptsr f0
Energy Efficiency-Chapter 1 t, see attached report
Mechanical-Chapter 12
General Mechanical Systems-Chapter 13
Heating and Cooling Equipment-Chapter 14
Exhaust Systems-Chapter 15
Duct Systems-Chapter 16
Combustion Air-Chapter I7
Chimneys and Vents-Chapter 18
Plumblng-PartVII
Sfmpson S~,ror~:2-Tle
N'2,S CLIPS e I~" O.C.
AT EACH STUD
GENERAL NOTES:
1. All work shall be pedormed in accordance with all state,
municipal, local zoning and betiding codes and ordinances
having Jurisdiction and best standards of construction
practice.
The American Institute of Architects Conditions shall apply
to all work performed on this project.
2. The Contractor shall vedN all conditions at the site, Any
discrepancies must be brought to the atiJention of the Engineer
prior to c~mmencement of consbustion. The Contractor shall be
except for hidden job conditions,
will be of good quality, free Imm faults and defects for a period
and/or the building as designed without the expressod wr~en
Insurance coverage Inctudlng ststufo~ pallcies (Worker
less that $5 million and automobile liability and damage
coverage not less than $2 million. The Engineer shall be
8. A single station smoke detector alarm devbe shall be installed
as per New Yark State Code.
1 t, All electrical work to be in accordance to the rules and
13. Do not scale drawings. Use figure dlmenslons only.
shall remain the property of the Engineer whether the pro)est for
Inspecitons and cer88catlans as required or requested by the owner,
FOLLOW PRODUCT SELECTION GUIDE AND
ANCHOR BOLTS IN FOUNDATION USE;
SSTB28 WITH BEARING PLATE, SEE FOUNDATION
NOTES FOR SPACING
SILL PLATE TO RIM JOIST USE:
LTP4 16" O.C. AT EXTERIOR PERIMETER
AND GARAGE/HOUSE COMMON WALL
USE 4 8d NAILS AT EACH END
GARAGE STUD TO GARAGE SILL PLATE USE:
SSP CONNECTOR AT f6" P.O.
USE 4 8d NAILS AT EACH END
RIM JOIST TO STUD CONNECTION USE:
MTS 12, 15" O.C.
USE 4 8d NAILS AT EACH END
FLOOR TO FLOOR CONNECTION USE:
MSTA 36, 10" O.C.
USE 4 8d NAILS AT EACH END
FOR CANTILEVER CONDITION USE MTS12, 16" O.C.
USE 4 8d NAILS AT EACH END
RAFTER TO STUD CONNECTION USE:
MTS 12, EACH ROOF RAFTER
USE 8 ~5d NAILS AT EACH END
RAFTER TO RIDGE TO RAFTER CONNECTION USE:
CS20 USE 6-tid NAILS IN EACH END
AT EACH ROOF RAFTER
DECK POST TO CONCRE]E CONNECTION USE:
PBS44A FOR EACH POST- USE 14 - 16d NAILS
DECK POST TO GIRDER CONNECTION USE:
PC44 FOR EACH POST
GIRDER TO DECK JOIST CONNECTION USE:
MTS12 @ EACH JOIST
PORCH POST TO DECK USE:
2 -AC4 - USE 14 - 16d NAILS
PORCH POST TO GIRDER USE: 2 - AC4
USE 14- 16d NAILS
PORCH ROOF RAFTER TO GIRDER USE:
MTS 12AT EACH ROOF RAFTER
m
m
crABIE 3.10 UJFCM HIGH UJIND EDITION)
ROOF 6HEATNING ATTACHMENT RE,QUIREMENT6 FOR UJIND LOADS
(110 MPH 3~ECOND GLINT · eOMPN FASTEST-MILE [gIND SPEED ~PER TAtSLE
SHEATHING LOCATION 6TUD SPACING STRUCTURAL SHEATHING MAXIMUM NAIL SPACING
(SEE NOTE I.) (INCHES. O.C.) OR PANEL bIDING FO~ B~ COMMON NAIL6
(~ NO~ 3) (INCH., O.CJ
CSI~ 1¼"COILED STRAP -
I&" O.C. USE 4-&d NAILS
-- AT EACH STUD, mRAp
UNDER 6ILL P~TE
MIN OV~LAP [6 12"
6TUg TO ROOF RAFTER
CONNECTION
6ILL PLATE TO RIM JOI6T AND
RIM JOI6T TO . TIJD CONNECTION
SImpeon Strc~ncI-T1e
C61~ I~" COILED STRAP -
I&" O,C, USE 4~t NAILS
AT ~CN 6T~D
MIN OVEELAp 16 2~ii
FLOOR TO FLOOR CONNECTION
CSI~ 1~." COILED
STRAp [UlN MIN 12"
OVERLAP AT EACH
FLOOR TO FLOOR CONNECTIONS-
CANTILEVER CONDITION
I/2" SPACING
ALLOWS
HOLDDO[/JN
INSTALLATION
(HOUR,)
I 3/4'1 MINIMUM
EDGE DISTANCE
:AT
24" O.C. ALLO!,US
HOLDDOiliN
IN~,TALLATION
COMMON
NAIL~ AT IO" O,C,
CONNECTED TO
/ 51mp~n S~.roncI-T1a
U210 2X~
AT EACH RAFTER:
4-1Od x I I/2"
NOTE:
ATTACH LEDGER TO FRAMIN~
MEMBER ~ITH 2-1/~" X 5" LA~
~OLT6 ~T I~" ON CENT~
WOLD DOUJN tSRACK. ET6 AT 8WEAR WALL CORNERS,
SEE pLAN
AND WINDOW AND DOOR OPENING
(FLOOR TO FLOOR 4 FLOOR TO
FOLINDATION;tUFCM FIGURE 3.E,a 4
eon
U210
EACH CEILING JOIST
4-10d x I I/2"
AT EACH DEC~./PORCH JOIE~T
4-1Od x I I/2"
FOUNDATION ~'~ TYPICAL PORCH/DECK ~T~=S ~lTh BP AT ~CH PO~T ~OTING T~51ON-~AP
ANCNO BOLT DETAIL PORCh COLUMN CONNECTION
P,4,GE:
4of4
~ECE~ED
FEB 0 1 2011
BOARD OF APPEALS
F:~ONT ELEVATION
I
i ~
I
FOUN~DATION pLAN
SECTION
PAGE:
2o~'2