HomeMy WebLinkAbout37335-ZTown of Southold Annex
P.O. Box 1179
54375 Main Road
Southold, New York 11971
CERTIFICATE OF OCCUPANCY
9/11/2012
No: 35938 Date: 9/11/2012
THIS CERTIFIES that the building
Location of Property:
SCTM #: 473889
Subdivision:
RESIDENTIAL ALTERATION
65 Ryder Farm Ln, Orient,
Sec/Block/Lot: 15.-8-1.4
Filed Map No.
Lot No.
filed in this officed dated
37335 dated 8/7/2012
conforms substantially to the Application for Building Permit heretofore
6/18/2012 pursuant to which Building Permit No.
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
"as built" conversion of existin~ barn to one family dwelling with covered entry and deck steps as applied for per ZBA
#6292, dated 7/30/09.
The certificate is issued to
Fischer, Nancy L
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED 8/20/12
R10-12-0044
37335
7/23/12
8/20/12
Joe Whitecavage
/~t~ riz~( Signa(ure
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 37335 Date: 8/7/2012
Permission is hereby granted to:
Fischer, Nancy
38785 Route 25
Orient, NY 11957
To:
"As Built", Conversion of an Accessory Structure (Barn) into a Single Family Dwelling;
Kitchen, Living Room, Dining Room, 3 Bedrooms, 2 Baths,
Foyer, Laundry, Decks, as applied for.
At premises located at:
38785 Route 25, Orient
SCTM # 473889
Sec/Block/Lot # 15.-8~
Pursuant to application dated 6/18/2012
To expire on 2/6/2014.
Fees:
and approved by the Building Inspector.
CO - ALTERATION TO DWELLING
SINGLE FAMILY DWELLiNG - ADDITION OR ALTERATION
Total:
$50.00
$1,402.40
$1,452.40
Building Inspector
Form No. 6
TOVVN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF occUPANcy
Thi~ application must be filled in by typewriter or ink and submitted to the Building Department with the follOWing:
A~ For new building or new use:
1. Final survey °f Pr°petty with accurat¢'localion of all buildings, property lines, streets, and unusual natural or
topographic featur6s. -
2.Final Appr°val fr°m Health DepL of water supply and aewemgcMisposal (S.9 fcwm).
Approval ofok~triea[ installation from Board 6fFire Underwriters.
' 4. 'aw. om statement from plumb, or ee, rtffying that tho solder used.in system contains leas than 2/10 of 1% lead.
5. Commer~nl building, industrial building, mtfltiptc reaidenoea and similar buildings and installations, a certificate
of Code ComPlianceTrom architect or engineer responsible for the building;
.6. Submit planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957} don-conforming us~s, or buildings 'and "pre--existgng" land uses."
1. -Accurate survey of property showing all property lines,'streeta, building and. unusufil natural or topographic
features. - ·
2. A properly -.~.:mpleted application and consent to inspect signed.by the applicant. If a Certificate of Occupancy is
denied, the BUilding Inspector shall state the reasons therefor in writing to the applicant.
1. Certificaie of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Akerations to dwelling
, Swimmirlg pop1 $50.00~ Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00;
2. CeFtifleat¢ of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $:25
· 4. Updated Certificate of OCcupancy- $50.00
· 5. Temporary Certificate Of Occupancy - Residential $15.00:, Commercial $15.00
lew Construction: Old or Pre-existing Building: ' (check one)
HOuse ]NO.
ttffolk .Co. un~ Tax Map NO1000, Section
abdiviai~n
Street
Fried Map.
q- ~ j>- ApplieaaK'
Undmwiter~ Approval:
Final Certificate:
Hamlet :
__ (check one)
Av~li~c nl Signature
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, NY I 1971-0959
Telephone (63 I) 765-1802
Fax (631) 765-9502
ro.qer, richert~town.southo d ny us
BUILDING DEPARTMENT
TOWN OF' SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Dan & Nancy Fischer
Address: 38785 Main Rd City: Orient St: NY Zip: 11957
Building Permit #: 37335 Section: 1 5 Block: 8 Lot: 1.1
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: as built DBA: Paul Burns Electric License No: 3892-e
SITE DETAILS
Office Use Only
Residential ~ Indoor ~ Basement ~ Service Only ~
Commerical Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
Service I ph
Service 3 ph
Main Panel
Sub Panel
Transformer
Disconnect
Other Equipment:
INVENTORY
Hot Water GFCI Recpt
NC Condenser Single Recpt
A/C Blower Range Recpt
Appliances Dryer Recpt
Switches Twist Lock
5-paddle fans, 2-exhaust fans
Ceiling Fixtures J~ HID Fixtures
Wall Fixtures 121 Smoke Detectors
Recessed Fixtures[~ CO Detectors
Fluorescent Fixture ~.~ Pumps
Emergency Fixturesl.~ Time Clocks
Exit Fixtures [~J TVSS
Notes:
Inspector Signature:
Date: Aug 20 2012
81-Cert Electrical Compliance Form.xls
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, New York 11971-0959
BUILDING DEPARTMF_aNT
TOWN OF SOUTHOLr~
Telephone (631 ) 765-1802
Fax (631 ) 765-9502
CERTIFICATION
Date:
Building Permit No. ~ 7ff~5
Owner: ,~'/',~ /~P~ Y L . F/ SC4/ffI~
(Please print)
Plumber: ,~o-~ t~ ,~: ~-~.~
(Please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1%
lead.
Sworn to before me this
day of~~ , 20
Notary Public,
County
(Plumbers Signature)
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST
[ ] FOUNDATION 2ND
[ ] FRAMING / STRAPPING [
[ ] FIREPLACE & CHIMNEY [
[ ] FIRE RESISTANT CONSTRUCTION [
[ ] ELECTRICAL (ROUGH)
REMARKS:
[ ] ROUGH PLBG.
[ ] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
] FIRE RESISTANT PENETRATION
'~ ELECTRICAL (FINAL)
DATE
iNSPECTOR~--- r'~~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]FIRE RESISTANT CONSTRUCTION
[ ]ELECTRICAL (ROUGH)
REMARKS:
[ ] ROUGH PLBG.
[ ]IN. iON
[/] FINAL
] FIRE SAFETY INSPECTION
] FIRE RESISTANT PENETRATION
] ELECTRICAL (FINAL)
DATE
INSPECTOR
JAMES J. DEERKOSKI P.E.
260Deer Drive
Mattituck, NY 11952
(631) 774 7355
jamesdeerkoski~yahoo.com
Date: August 24, 2012
To: Town of Southold Building Dept
Re: Fischer
38785 Route 25
Orient, NY 11957
Permit# 37335
To Whom It May Concern:
This letter certify that the conversion of an Accessory Structure into a single family
dwelling at the above mentioned location has been built in conformance with all local
and New York State Building Code. Also this structure has been constructed to the
specifications of the submitted plans. Ox.
,C.,,Any questions feel free to call.
'.,. Singerely,
Jhlnes'J Deerkoski P.E.
mL~~Om~,OX~ ~,~ CO .M~Va~S ·
FOUNDATION (1ST) ~ !
ROUGH ~G & ~ ~
PL~G
STA~ E~R~ CODE
~1~/ /~ '~ ~ "
I I/)~
,
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWn
SOUTHOLD, NY 11971
FAX: (631) 765-9502
SOutholdTown. NorthFork. net
B~ldiag Insp~or
BUILDING PERMIT APPLICATION CHECKLIST
Do y~m have or need It~ foil~. ~ing, before applying?
Board of Health
4 sets o f Building Pisris
Planning Bo~aooroval
Survey V'
Cheek
Septic Fomt
T~
Storm-Water Asses.n'aent Form
APPLICATION FOR BUILDING PERMIT
Date
INSTRUCTIONS
;20//
o. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, aecurate plot plan to scale. Fee aecording to schedule.
b. Plot plan showing location of lot and of binldings on premises, relationship to adjoining premises or public streets or
~re&s, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any pta-pose what so ever until the Building inspector
issues a Certificate of Occupancy.
L Every builtFmg permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. lfno zoning amendments or other regulations affecting the
property have been enacted in the int¢fim~ the Building inspeetot may aulhotize, in.writing, the extension of the Perrmt for an
addition s~x months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to thc B uihTmg Department for the issuance of a Building permit pursuant to the
Building Zone Ordinance of the Town of Senthold, Suffolk Couaty, New York, and other applicable Laws, Ordinances or
Regulations, for the constxuction of builffmgs, additions, or alterations or for removal or demolition as berein described. The
applicant agrees to comply with all applicable laws, ordinmcea, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
{~aatu~ of I~pticant or name, if~ corporation)
(Mailing a4dress of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Nameorownerofpremises/~ ~CV L. ~/~t C.h~/
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
0qame and title ot'c0rP°mte officer)
Builders Lieens¢ No.
Plumbers License No.
Electricians License No.
Other Trade's License
1. Location of land on which proposed work will he done:
--%¢ ;'A.c /~,,~.., /eo,,_.g
House Number Street
Hamlet
County T~x Map No. 1000 Section /~ Block afl Lpt //
Subdivision Filed Map No. Lot,
2. State existit~g use anti occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy
b. Intended usc and occupancy
3. Nature of work (check which applicable): New Building Addition
Repair Removal Demolition Other Work
- 4. Estimated Cost Fee
5. If dwelling, number o f dwelling units
If garage, number of cars
Alteration
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. Ifbusincss, commercial or mixed occupancy, specify nature and extent of each type of ese.
7. Dimensions of existing stmctares, if any: Front ~'2- Rear Jif. Z. Depth
Height -/~'" ~',~ ~,d~e Number of Stodes /
Dimensions of same structure with alterations or additions: Front 6,.4/z-/Y,~/y'~'fB Rear
Depth Height.__~ Number of Stories
8. Dimensinns of entlrc new constructinn: Front ~/Y ~)Y,d///d ~r Depth
Height . Number of Stories /
11. Zone or usc district in which premises arc situated ,~_
12. Docs proposed construction v oJatc any Zoning law, ordinance or regulation? YES__ NO v/
13. Will lot be re-graded? YES NO ,~11 excess fill be removed from premises? YES NO
1 $ a. Is this proporty within 100 fcct of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE ~EQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO v"
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If clevatinn at any point on property is at 10 feet or below, must provide topographical dam on survey.
18. Are there any covenants and restrictions with respact to this property? * YES
· IF YES, PROVIDE A COPY.
NO
STATE OF NEW YORK)
~' 1[,13 [".'~ ' L ~ ~ Ch~.~- being duly sworn, dcpescs am:l says that (s)be is the appliceat
(Name o f individfial signing contract) above named,
(Contractor, Ag~at, Corporate Officer, etc.)
of said owner or owners, and is duly authorlzcd to perform or have performed the said work and to make and file this application;
that all statements contained in this application orc haae to the best of his knowledge and belief, and that the work will be
performed in thc manner set forth in thc application filed therewith.
Sworn to before me th'~ ~ .
~/ N~tary~ublic LINDA $. CARLSON S;g~a~rcdfApplicant---'~..~
Notary Public, State of New York
No. 01CA6137178
...___O~al)fied_in Suffolk County
Office Location:
Town Annex/First Floor, Capital One Bank
54375 Main Road (at Youngs Avenue)
Southold, NY 11971
Mailing Address:
53095 Main Road
Rd. Box 1179
Southold, NY 11971-0959
http://southoldtown.north fork.net
BOARD OF APPEALS
TOWN OF SOUTHOLD
Tel. (631) 765-1809 Fax (631) 765-9064
FINDINGS, DELIBERATIONS AND DETERMINATION
REGULAR MEETING HELD JULY 30, 2009
ZBA File # 6292 - Daniel and Nancy Fischer
Property Location: 38785 Route 25, Orient
CTM # 1000-15-08-1.1
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this
application and determines that this review falls under the Type II category of the State's List of Actions, without
further steps under SEQRA.
SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk
County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its
reply dated ?? _2009 stating that this application is considered a matter for local determination as there
appears to be no significant county-wide or inter-community impact.
PROPERTY FACTS/DESCRIPTION: The applicant's property contains 72,665 square feet in area and is
improved wilh a single-family, two story frame dwelling, a one story frame improved barn and two accessory
structures (play house and shed), as shown on a survey prepared by John T. Metzger dated April 12, 1990 and
revised June 16, 2008.
BASIS OF APPLICATION: Requests for Variances, based on an application to the Building Department and the
Building Inspector's February 4, 2009 Notice of Disapproval concerning a proposed subdivision of property for
the following reasons: (1) the proposed subdivision is not permitted with less than a minimum 40,000 square
foot lot size in the R-40 District, for proposed Lots #1 and #2; (2) the existing as-built (without permits) one story
structure is proposed on Lot #2 with a side yard setback at less than the code-required minimum of 15 feet (3)
the existing accessory shed is less than the code required minimum of 10 feet.
Note: Shed was moved to conform with side yard setback code provision upon granting of proposed subdivision
and new proposed lot lines.
FINDINGS OF FACT
The Zoning Board of Appeals held a public hearing on this applicalion on June 25, 2009, at which time written
and oral evidence were presented. Based upon afl testimony, documentation, personal inspection of the
property, and other evidence, the Zoning Board finds the following facts to be true and relevant:
· Page 2- ,luly 30, 2009
ZBA File Ct 6292 - Oaniei and Nancy Fischer
Property Location: 38785 Route 25, Odent
CTM # 1000-15-8-1 1
AREA VARIANCE RELIEF REQUESTED: The applicant is requesting area variances for a proposed
subdivision of the existing parcel into two equal sized lots. The area variances are for a lot size of 36,333 square
feet for proposed Lot #1 and a lot size of 36,332 square feet for proposed Lot #2 where the code requires a
minimum of 40,000 square feet per Lot. Proposed Lot #2 will also require an area vadance for a Side Yard
setback reduction with the conversion of the existing improved accessory barn structure into a principal dwelling.
This existing improved accessory barn structure has a Side Yard setback of 11.4 feet where the code will require
a 15.0 foot Side Yard setback. As shown on the Survey of Property prepared by John T. Melzger L.S dated
April 12, 1990 and revised June 16, 2008.
ADDITIONAL INFORMATION: The applicant has previously been before the board under ZBA Fil~ # 5883
requesting area variances for a similar subdivision of this same parcel and was denied relief.
In response to a request for comments from the ZBA, The Town of Southold Planning Board, in a Memorandum
dated May 4, 2009 addressed to the Zoning Board of Appeals states that it has inspected the site and analyzed
the lots and lot sizes in the surrounding neighborhood and has concluded that it has no objection to the issuance
of the requested variances under this application.
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal
inspections, the Board makes the following findings:
1. Town Law §267-b(3)(b)(3)(1). Grant of the variances will not produce an undesirable change in the
character of the neighborhood or a detriment to nearby propedies. The proposed lot sizes are consistent with
the existing lot sizes in the surrounding neighborhood. The side yard variance requested adjoins a Town of
Southold owned Recharge Basin, which is heavily vegetated and buffers the existing improved accessory barn
structure from the neighboring property to the North.
2. Town Law §267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method,
feasible for the applicant to pursue, other than area variances. The existing parcel is 72,665 square feet and
therefore cannot be subdivided to create two cede conforming lot sizes of 40,000 square feet each.
Upon granting the approval of the lot size variances to create the subdivision, the improved existing accessory
barn structure will require a Side Yard variance because it will then be interpreted as a dwelling under the code.
3. Town Law §267-b(3)(b)(3). The area variances for the two proposed lots require a 9.17% variance each,
which is not substantial. The side yard variance would be 24% and not substantial when considering this Side
Yard adjoins a well vegetated Recharge Basin.
4. Town Law §267-b(3)(b)(5). The difficulty to require variances for the two equal lot sizes of the proposed
subdivision has not been self created because the original parcel consists of only 72,665 square feet where the
code would require 80,000 square feet in this padicular case. The difficulty has been self-created with respect
to the request for a Side Yard vadance for the improved existing accessory barn structure. The difficulty came
when the owner improved an existing conforming accessory barn structure to a dwelling.
Page 3 - July 30, 2009
ZBA File # 6292 - Daniel and Nancy Fischer
Prope~ Location: 38785 Route 25, Orieut
CTM # 1000-15~-1~1
5, Town Law §267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential
community will have an adverse impact on the physical or environmental conditions in the neighborhood.
6, Town Law §267-b. Grant of the relief requested is the minimum action necessary and adequate to enable the
applicant to enjoy the benefit of the subdivision of his property, while preserVing and protecting lhe character of
the neighborhood and the health, safety and welfare of the community.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under
New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member
Weisman, and duly carried, to
GRANT the variance as applied for, as shown on the Survey of Property (1000-15-08-1,1) by John T.
Metzger, dated April 12, 1990 and revised June 16, 2008.
Vote of the Board: Ayes: Members Goehringer (Chair~n, we?~smaa...and Schneid/er. This Resolution
was duly adopted (4-0).
/ /C~-rd P. Goehringer, Chairman,~//.,~009
$oulhold Town Cleft
Town of Southold
Erosion,Sedimentation & Storm-Water Run-off ASSESSMENT FORM
PROPB~TY LOGAT~N: 8~,TJ~ ~: THE FOLLOWIN~ ACTION8 MAy REQUIRE THE 8UBMI88~ON OF A
L~ GAkii~ir'u BY A D~al~e( PROFESSIONAL IN I~E ~I'ATE OF NEW YORK.
$COPEOFWO~ - ]~O~OSED CON~-IIKi~CTZON IT~# / ~O~A~$Y-~-~T I Yes No
(Include Total Ama of all Parcels rocatsd w~hin I Will this Pm~ct RMaIn AIl Stom~-Water Run-Off
Slop~ ~g S~ Wa~r F~.
and ~m~ ~1 ~s ~ ~ ~ u~ ~
~ m~ be ~n~ned ~ghout ~ En~
~n P~.
E~g O~e In~ ~ ~ ~ ~Y~s
~al ~ any ~?
5 ~1 ~is ~on ~ulm ~ ~ ~
(5,~ S.F~) S~m F~ of G~nd Su~?
~? Is ~ ~Je~ ~ ~e ~d~
~ ~ ~ ~: or~ffi~ ~ ~ (1~') ~ ~ a ~ ~
~ ~ W~ ~ ~ ~ ~. ~ ~ ~.1 Su~ ~ S~p~ ~ Dlm~ ~-W~ ~
~'AI~ OF NEW YO~ C ~ t ~
~at~he~
0~ ~or ~pm*m~fi~ of ~e ~er or ~, ~d ~ d~ ~d~o~d m ~o~ or ~ peffo~ ~e ~d ~ ~d m
· at ~ ~rk ~ ~ ~om~ in ~e m~ ~ f~ ~ fl~e ~p~on ~ h~dfl~.
S~m m b~o~ me ~;
FORM - 06/10
Notary Publlc, State of New York
No. 01 CA6137178
Qualified in Suffolk County /.~
Commission Expires Nov. 14, 20
P.O. ~ 11~9
TcJcpbonc ((~1) 7~1~0~
BUn ~G DEPAI~q~IENT
TOWN OF 8OUTHOT.n
APPLIC^TION FOR I::LECTRICAL INSPEOTION
REQUESTED BY:
, Name:
Name:
Date:
JOBSITE INFORMATION: (*Indicates required information)
*BRIEF DESCRIPTION OF WORK (Please Print Cleady)
(Please Circle All That Apply)
*Is job ready for inspection:
*DO you need a Temp Certificate:
~NO Rough In ~
YES / NO
*Sen~ce Size: 1 Phase
*New Service: Re-mnnect
Additienal Information:
Temp Infonnatlen (If. needed}
3Phase
Unden3round Number of Meters Change of Sen~ce
PAYMENT DUE WITH ~d:~PLICATION
82q~uest ~o~ In~oecUon Fo~m
PLANNING BOARD MEMBERS
DONALD J. WILCENSK/
Chair
WILLIAM J. CREMEHS
KENNETH L. EDWARDS
JAMES H. RICH III
MARTIN H. SIDOR
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
MAILING ADDRESS:
P.O. Box 1179
Southold, NY 11971
OFFICE LOCATION:
Town Hall Annex
54375 State Route 25
(cor. Main Rd. & Youngs Ave.)
Southold, NY
Telephone: 631 765-1938
Fax: 631 765-3136
June 5, 2012
Charles R. Cuddy, Esq.
P.O. Box 1547
Riverhead, NY 11901
Re~
Final Approval: Standard Subdivision for Daniel Fische_r
Located at 3878~ NYS Route 25, ~)ri~nt
SCTM#1000-15-8-1.1 Zoning District: R-40
Dear Mr. Cuddy:
The Southold Town Planning Board adopted the following resolution at a meeting held
on Monday, June 4, 2012:
WHEREAS, this proposal is to create a 2-lot standard subdivision on a 1.6682 acre
parcel where Lot 1 is 36,333 square feet and Lot 2 is 36,332 square feet in the R-40
Zoning District; and
WHEREAS, the Southold Town Zoning Board of Appeals granted approvals for Lots 1
and 2 for lot area variances and a side yard setback variance on July 30, 2009; and
WHEREAS, on March 9, 2010, the Southold Town Planning Board granted Sketch
Approval on the map prepared by John Metzger, L.S., dated July 15, 2009; and
WHEREAS, on September 13, 2010, a Preliminary Public Hearing for the above-
referenced application was held and closed; and
WHEREAS, on November 15, 2010, the Southold Town Planning Board granted
Conditional Preliminary Approval; and
WHEREAS, on February 24, 2011, the agent submitted an application for Final Plat
Approval along with the Final Application Fee in the amount of $500.00; and
Fischer PaRe Two June 5, 2012
WHEREAS, on October 3, 2011, the Southold Town Planning Board reviewed the
Office of the Town Engineer's comments and decided that in place of a full SWPPP the
Board would require storm water calculations; and
WHEREAS, on April 9, 2012, the agent met with the Planning Board at their Work
Session to discuss the requested storm water calculations. The Planning Board agreed
that the calculations were not necessary due to the fact that the site is already
improved. Additionally, the Planning Board required a Covenant and Restriction
restricting that storm water be retained on-site; and
WHEREAS, on April 18, 2012, the agent submitted revised Covenants and Restrictions;
and
WHEREAS, on April 25, 2012, the agent submitted the required Park and Playground
Fee and the Administration Fee; and
WHEREAS, on May 16, 2012, the agent submitted five mylars and six paper prints
which had been endorsed by the Suffolk County Department of Health Services; and
WHEREAS, on May 21,2012, the Planning Board, at their Work Session, accepted the
revised Covenants and Restrictions and agreed to waive the final hearing pursuant to
Section 240-56 of the Southold Town Code; and
WHEREAS, on May 30, 2012, the agent submitted Covenants and Restrictions
recorded with the Suffolk County Clerk, Liber 12694 and Page 708; be it therefore
RESOLVED, that the Southold Town Planning Board grants Final Approval, on the ma~q,
~.ntitled "Final Plan Fischer Property", dated Aori112. '[990 and last revised January 17,
~2012, prepared by John T. Metzger, Peconic Surveyors P.C., a~zes the
Chairman to endorse the map.
Upon endorsement of the Final Plat by the Chairman, the mylars and paper prints
must be picked up at this office and the Final Plat filed with the Suffolk County
Clerk by the applicant within 62 days of the date of Final Plat Approval, or such
approval shall expire. Final Plat Approval shall be determined in accordance with
§276 of the New York State Town Law.
Final Plat is void if revised after approval. No changes, erasures, modification(s),
or revisions shall be made to any Final Plat after it has been approved by the
Planning Board, and such approval has been endorsed in writing on the plat,
unless the said plat is first re-submitted to the Planning Board and the Planning
Board approves any modifications. In the event that any such Final Plat is filed
without complying with this requirement, the same shall be considered null and
void, and the Planning Board shall institute proceedings to have the Final Plat
stricken from the records of the Suffolk County Clerk.
Fischer PaRe Three
June 5,2012
If you have any questions regarding the above, please contact this office.
Very truly yours,
Donald J.~censki
Chairman
Encl.
cc: Building Dept. w/map
Assessors w/map
,, 3 733-
BUILDING PERMIT EXAMINER CHECKLIST" *Date Submitted: 6 -~- [ ~l.~ Date Reviewed:
Appheant: . /V ~ ~ ~ ~ Owner: ~ff~ ~~
8CTM, 1000- /S -- g I, ~ Subd,wsmn: 0.~~Zone: a'~° Conforming?~
Property Address:
Building Permits (Open/Expired): B? -Z / C/0 Z- , Info:
BP __-Z / C/0 Z- , Info: BP -Z / C/0 Z-
Single & Separate Search Required? Y or~2)Determination:
REQ. Lot Size: ACT. Lot Size:
REQ. Front ACT. Front REQ Side
, Info:
ACT. Side
City:
Pre COs7
BP __-Z / C/0 Z- , Info:
BP__-Z / 12/0 Z- , Info: __
REQ. LOt Coy. o~o'~ ACT: Lot Cov.
REQ. Rear__ PROP. Rear
REQ. Height. 3~t ACT. Height. R~Z~. $o'r8 $1~5 .. /I CT
Waterfront~ o(~ ~ ~ ~~ ,
lfy~, water body: - Panel~ '- Flood Zone: ~ BUl~ea~BluffDistance:
~DITIONAL APPROVALS ~QUI~D ~C~ ~ (¢) SI~, ~[~ O~u~V~ ~
Suffolk County Health: or N- If yes, *Bed~: ~ *Date: ~-~ff~Permit~: g 10-l~-~rown Septic:
' - If no, certification required: Y or N Received: Y or N By:
~S DEC: ea~c ~at*5 Y or~ Date: / / Permit ~: or NJ Letter - Notes:
Southold Trustees: Y o~- Date: / / Permit ~: or NJ Letter - Notes:
SoutholdZBA~rN-Date: 7/ff~/ 07 Permit~: -Notes:
Southold Planning:~or N - Date: ~ / ¢ / ]~ Permit ~: - Notes: ~ ]d7-/2~ ~ ~
Town Landmark C of A: Y o~TE: / / *~S CODE ~omp~ance (page 2): Y or
.Fee Structure:
Foundation: 33 SF
First Floor: I ~' ~' 0 SF
Second Floor: SF
Other: SF
Total: [ o~-..,q',z3 SF
Calculation:
(2 oFo
1°a'5-3 xs ,5-o I ,,,to
+ Initial Fee: $ ~-O 0, o O
+ Additional Fee ( ): $
SFX$,
+ Initial Fee: $
+ Additional Fee ( a4-$u~:): $ 70 ]. kO
.5-0,oo
8UlkT FIZE q~70/.;l. 0 TOTAL:$ Iff`oil., '.f-o
NEW YORK STATE CODE COMPLIANCE CHECICLIST
C.LIMATIC/GEOGRAPHIC DI~SIGN CRITERIA:
Grolmd Snow Load: ~0
Weathering: Severe__ -Frost Depth: 36"__
Design Temp: 11 __ 'Ice Shield Underlay: YE8
USE/OCCUPANCY CLASSIFICATION'.
HEIOIZIT/FIRE AREA:
TYPE OF CONSTRUCTION:
DESIGN CRITERIA: ENGINEEREDfPRESCRIPTIVE
FULL FRAMING DESIGN ELEMENTS: Y/N
HEADERS: Y/Iq WALL ST1UI)s: Y/N
CEILING JOISTS: YfN FLOOR JOISTS: YfN
LUIM[BER SPECIES AND GIR_AI)E: YfN
Wind Speed: 120MPH__ Seismic Design Categoryi B ,
Termite: M-H' Decay: S-M
Flood Hazards:
GIRDERS; Y/lq
ROOF
WINDOW AND DOOR SCHEDULE:
· MISSLE TEST REQUIREMENTS: Y/N
EGRESS 5.? S.F.: Y/iN
LIGHT 8%: Y/N
~rENT 4 %: Y/N
NAILING/CONSTRUCTION SCHEDULE: Y/N
MEANS OF EGRESS: Y/N
PLUMBING RISER DIAGRAM: Y/N
LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N
TRUSS DESIGN: Y/N
CERTIFICATION: Y/N
ENERGY CALCS: YfN (R~$¢it~c~
TOTAL COMPLIENCE7 Y/N (~TU~ TO ]PAGE ONE)
MAP OF ORIENT BY THE SEA FILED OCT. 23, 1961 FILE NO. \
3444
TOWN OF SOUTHOLD
FINAL MAP
REVIEWED BY ZBA
SEE DECISION # ~,~
PAVED '~
--I --I'--'-Q91YQ
# NOI$1O=IO =l=lS
YSZ A8 aaM~llA~t~l
dVlN "]¥NI.-I
SURVEY OF
PROPER T Y
A T ORIENT
TOWN OF SOUTHOLD
SUFFOLK COUNTY, N. Y.
1000 - 15 - 08 - 1.1
Scale I"= 40'
April 12, 1990
._' ,., :f~/..~ 4~.~. ~.N_o,.~'~'~ '
90- 170
SCDHS Re/.#
MAP OF ORIENT
N 88' 28' 00" E
107,08:
. p
BY- THE'
LOT
FILED ~)cT. 23, I;81 FILE NO.
3444
SOUTHOLD
Town OF
N 88' Off' 20" E
c~
L 0 T NUMBERS ARE REFERENCED TO ~
SUBDIVISION- "FISCHER PROPER~'Y'
FILED IN THE OFFICE OF THE SUFFOLK
COUNTY CLERK.
SURVEY OF PROPERTY
AT
ORIENT
TO WN OF SOUTHOLD
SUFFOLK COUNTY, N Y.
lOqO - 15 - 08 - PlO L 0 T 1.1
(~ x I SI'Y FR.
,' HOUSE
Sca/e: 1" = 40'
July 3, 2012
oO S
~o
Ted Borinq
by ~¢DONALD G£OSCIENC[
II/I;Z/09 c"L
)ARK BRO~N LOAM
· OL
~ROWN SILT OL
18'
BROWN FINE
COARSE.~4ND SW
[ F~£ TO COARSE
SAND SW
The locations of wells and cesspoo~
shown hereon are from field observations
and or ~om dolo obtained ~om o/hers.
Therefore lhe~ Iocdions and or exisle~ce
~ no/ gu=ranlee~
am familiar with the STANDARDS FOR APPROVAL
AND CONSTRUCT/ON OF SUBSURFACE SEWAGE
DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES
and will abide by /he conditions se/ forlh /herein and alt /he
perm# to consiruc(.
FEMA FLOOD ZONE
A,VY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION
OF SECT/ON 7~09 OF THE NEW YORK STATE EDUC~ TION LAW.
EXCEPT AS PER SECTION 7~09 - SUBDI~ E. ALL CERTfF~CATION$
HEREON ARE VALID FOR THIS MAP ~ COPIES THEREOF ONLY IF
SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR
IVNOEE S/GNA TURE APPEARS HEREON.
ELEVAT/ONS ARE REFERENCED TO NA VD88
N,'~'~S, LI~i NO. 49618
/~ECONIC S'U~/YEYORS, P.C.
[651] 765 - 5020 FX (631) 765 - 1797
P.O. BOX 909
/230 TRAVELER STREET
SOUTHOLD, N.Y. 11971 90-1 TO
GENERAL NOTES
CONSTRUCTION NOTES:
FOUNDATION NOTES:
FRAMING NOTES
WIND FRAMING NOTES
DECK AND COVERED PORCH NOTES:
PLUMBING NOTES
HVAC SYSTEM NOTES
ELECTRICAL NOTES:
NAILING SCHEDULE
ROOE _FRAMING:
WALL FRAMING:
FLOOR FRAMING:
~OOF SHE/ ,TFlNG:
CEILING SHEATHING:
WALL SHEATHING:
FLOOR SHEATHING:
NOTES:
PLAN CONTENTS:
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA
ROOF SHEATHING REQUIREMENTS FOR WIND LOADS:
4' PERIMETER EDGE ZONE
NOTES
WALL SHEATHING REQUIREMENTS FOR WIND LOADS:
NOTES
NOTE;
WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS
. :, ' ~ SCDHS ReL # SlO-10-O004
~ N 88' 2~' 00' E, l~,~l' I ~__ " ' ' ~ (NOT TO SCALE
/ ~'r o~rr.
de"r ~ erm~.
UTILITIES
ELECTRIC
TELEPHONE
CA BL EVISION
SEPTIC SYSTEMS
PRIVATE WELLS ~.~
FEMA FLOOD. ZONE X -
ELEVATIONS ARE REFERENCED TO NAVD$8
AREA = 1.6682 Acr~
Tesl Belin
~°~ ' FINAL PLAN
FISCHER PROPER TY
AT ORIENT
TOWN OF SOUTHOLD
SUFFOLK COUNTY. N. Y.
Scale I;' = 40'
APRIL 12, 1990
Dec. 7, 2009
Jan. /4, 2010 (trees) .
Marcho~,.6, 2010 faddillons)
Aug. 5~ 2010 ~revi$ions)
Dec. 31~ ZOiO (~dd/I/ons)
· Covenam & Re~ctlon~
/"~E ~ zP'-L~L PAGE ~._.~_~
APPROVED BY
PLANNING BOAR, D
TOWN OF SOUTHOLD
DATE JUN O- $ ~012
SUFFOLK COUNTY DEPARTMENT OF HEALTH' SERVICES
~ HAUPP~AUGE~ N.Y.
FEB ! 7
_ ROAD
P~
APPROVED IN ACCORDANCE WITH BOARD OF
R~V[EW DETERmINATiON DATED ~T ~ ~ ~ ~ ~ ~ ~CT TO S~
I HERESY CERTFY THAT THE WATER SUPPLYI$) AND/OR SEWAGE DISPOSAL
FOR TNIS PROJECT WERE DESIGNED BY ME OR UNDER MY DIRECTION
CAREFUL AND TROROUC+I STUDY'OF THE SOIL~ SITE AND
GROUND R CONDITIONS ALL LOTS AS pROPOSED,-CONFOR~ TO THE
SUFFOL~ Y DEPARTMENT OF HEALTH SERV CES CONSTRUCTION
OF THIS DATE.
FIRE DISTRICT -
SCHOOL DISTRICT
- ORIEN7
The locations of we/Is and cesspools
shown hereon ore from field observofions
end or from do/~ obtoined .from o/hers.
Therefore Iheir Ioco/ion$ end or exislence
Is nol guaron/eed.
NYS LIC NO. 49619
s, P.C.
(631) 765 - 50~0 FAX 1631) 765 - 1797
P. O. BOX 909
IZ$O TRAVELER STREET ('~i'~ I
$OUTHOLD, N.Y.
SCDH$, Ref ¢/: RIO-II-OOJ8
APPROVED (BARN]
CROSSECTION HEX SEPTIC SYSTEM
..... ~ .~ ~ow~ o, ~o~,o,~ .......
N
UTILITIES
EL EC TRIC
TELEPHONE
CABLEVIS/ON
GAS
SEPTIC SYSTEMS
PRIVATE II~"LLS
FEMA FLOOD ZONE X
ELEVATIONS ARE REFERENCED TO NAVD88
AREA = 1.6682 Acre~
18'
FISCHER PROPE/? TY
~ A T ORIENT
TOWN OF SOUTHOLD
SUFFOLK COUNTY, N.Y.
!000- 15- 08 -
1.1
Scde 17 = 40'
APRIL 12, 1990
Dec. 7, 2009
JQn. /4~ 2010 (/Tees,
JUNE 8~ 2011
JUL Y ~5, ~011 (revisions]
CROSSECTION IMPROVED SEPTIC SYSTEM Ely. Fr. Rouse)
EL, 12.5
RI o - I/, o
The Iocallon$ of wells and cesspools
shown hereon are from field observalions
and or from data obtolned from ofhers.
Therefore Iheir Iocafions and or ex/slence
i$ nor guoranfeed,
(EJll 765-5020 FAX (631I 765-1797
P.O. BOX 909
1250 TRAVELER STREET
SOUTHOLD, N.Y. 11971 ,?~0-/ ~0
GENERAL NOTES:
1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS
FIR - LARCH, STRUCTURAL GRADE NO. 2 OR BETTER.
2. ALL SHEATHING TO BE APA RATED, STURD-I-FLOOR, EXPOSURE
1, 5/8" MIN. THICKNESS'OR AS NOTED.
3. ALL SUBFLOORING TO BE APA RATED, STURD-I-FLOOR,
EXPOSURE 1, 3/4" MIN. THICKNESS.ALL EDGES OF PLYWOOD TO BE
SET ON SOLID BLOCKING. GLUE AND NAIL PLYWOOD SUBFLOOR
TO JOISTS.
4. ALL HEADER'S 6'-0" AND OVER SHALL BE SUPPORTED WITH
DOUBLE UPRIGHTS, 9'-0" AND OVER WITH TRIPLE UPRIGHTS. ALL
HEADERS SHALL BE A MINIMUM OF 2) 2 x 8'S, OR AS SHOWN ON
DRAWINGS.
5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND
FLOOR BEAMS AS PER N.Y.S. CODE, OR AS NOTED, @ 8'-0" D.C.
MINIMUM. PROVIDE 2" SPACE FOR AIR CIRCULATION IN ROOFS.
6. DOUBLE FRAMING AROUND ALL OPENINGS (stairs, skylights,
chimneys, etc.), OR AS NOTED ON DWGS.
7. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL
PARTITION, OR AS NOTED ON DWGS. Nailing Zones for Roof Sheathing in 120
8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH MPH Peak Gust Wind Zone
RATED GALVANIZED METAL CONNECTORS BY "TECO" OR -- --
APPROVED EQUAL.
9. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. BUILDING Rancid,,, r 6 o.c. r ,.o.c. I ' o.c. r
CODE AS A MINIMUM. ALL 2 x 6 STUDS SHALL RECEIVE 5) 1Od
Nailing Raqulmmente for 120 MPN, 3 Beg. Peak Gust,
NAILS AT SILL AND PLATE. ALL EXTERIOR NAILS SHALL BE ~"~lckRoof Bheathlag with 8d Common Nails
GALVANIZED. Roof Sheathing Nailing Details
10. PLYWOOD SHEATHING TO BE NAILED WITH 8d @ 4" O.C
EXTE?.R EDGES AND
6a @ 2 D.C. INTEmEDIATE.
11. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING AND
WATER-PROOFING..
12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND
STUDWITH GALVANIZED HURRICANE TYPE CONNECTORS BY
"TECO" OR APPROVED EQUAL. FOR TIMBER PILE FOUNDATIONS,
PROVIDE HUIL~CANE CLIPS AT ALL PERIMETER JOISTS TO GIRDER
CONNECTIONS.
13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA PACIFIC
GPI SERIES WOOD I-BEAMS AND LVL PRODUCTS OR EQUAL. ALL
JOIST GIRDERS AND HEADERS SHALL HAVE BEARING STIFFENERS
INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS. WEB
STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND BEARING
POINTS AT A MINIMUM. A SINGLE 1 3/4" LVL RIM JOIST SHALL BE
REQUIRED AT FLOOR PERIMETERS. HANDLING, STORAGE, AND
ERECTION OF COMPONENTS SHALL BE AS PER MANUFACTURERS
RECOMMENDATIONS.
14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" DIA.
GALVANIZED MACHINE BOLTS @ 12" O.C.
WINDOWS - GLAZED OPENING
FOR NEW CONSTRUCTION, EXTERIOR WINDOWS MUST BE PROTECTED VIA GLAZING MEETING
THE LARGE MISSILE TEST CERTIFICATION OF ZONE II ASTM E 1886-97 AND ASTM E 1996-99
OR VIA STRUCTURAL SHUTTERS WITH ATTACHMENT HARDWARE PROVIDED. NEW STRUCTURES
LOCATED WITHIN ONE (1) MILE OF THE MEAN HIGH WATER MUST HAVE GLAZING CONFORMING
TO WIND ZONE III, MISSILES DEFINED IN PARAGRAPH 6 OF ASTM E 1996-99. GLAZING CONFORMING
TO WIND ZONE II, MISSILES CAN BE USED AT A DISTANCE GREATER THAN ONE MILE OF THE COASTLINE.
Table 3.1 Nailing Schedule (Woed Framed Construction Manual 1995 BBC High Wind Edi~n, Page 110)
JolrdDesedption ] NumberofNails r NailSpadng
ROOF NAILING
Rafter to Top Plate (Toe -nailed}
Ceiling Joist to Top Plate (toe -nailed)
Ceding Jaist to Pamllai Rafter (Face -nailed)
Ceiling Joist Laps Over Par~tices (Face -nailed}
Collar Tie to Rafter {Toe-nailed)
Blocking to Rafter (toe nailed)
Rim Board to Rafter (End Nailed)
WALL FRAMING
:4-8d
4-8d
· 16d
2-1~d
2-8d
2 - 16d
Top Plate to Top Plate (Face -nailnd)
Top Plates at Intemectlons (Face -nailed)
Stud to Stud (Face -nailed)
Header to Header (Face -nailed)
Top or Bottom Plate to Sted (End Nailed)
2- 16d (1)
4-16d
2- 16d
16d
2-16d
3 - 16d
4-16d
permit
per jaist
each lap
each
perUe
each end
each end
per fcet
joists - each aide
24' o.c.
16" c.c. along edges
par 2x4 stud
per 2x6 sted
per 2x8 stud
Bottom Rate to Floor Joist, Band Joist, End joist or Bloc, king (Tce-nallad) 2 - 16d (1,2) per foot
FLOOR FR,~IING
Joist to Bill, Top Plate or Girder ('roe -nailed) :.~ 4 - 8d per Joist
Bridging to Joist (toe-nailed) f 2 - 8d each end
Blocking to Joist (too-nailed) 2- 8d each end
Blacking to Bill or Top Plate (Toe-nailed) 3 - t 6d each block
Ledger Strip to Beam (Face-nailed) 3 - 16d each joist
Joist on Ledger to Beam (toe-nalted) 3 - 8d par jobt
Band Joist to Joist (End-nailnd) 3-16d per jofst
Band Joist to Sill or Top Plate (Too-nailed) 2 - 16d (1) per fcet
ROOF SHEATHING
Structural Parole 8d (Detail shoot
CEILING SHEATHIN
,Gypsum Waillx~rd ftd ceaiers I 7" edge / 10"field
WALL SNEATHINI
Structural Panels
Gypsum Wallboard
8d 8" edge / t 2" field
5d coolam 7" edge / 10" field
FLOOR SHEATHING
Structural Panels 8d
t' o.r less 6" edge / 12" field
(1) Nailing r~,',lremenla are based on wall shaathlng nailed 6 co-center at the panel edge. If wll shaathlng Is nailed 3
on-coMer at the panel edge to obtain higher ahaar oapaaitlas, nailing requirements thr structural membom shall be
doubled, or altemate connectom, such as shear plates, shall be used to malotela load path.
(2) When 1,'edl sheathing lo continuous over connected membam, the tebulai~ number of nails shall be pen~lfted to be
reduced to 1 - t 6d nail per foot.
SIMPSON L~TA~6
STRN~
RETAIN STORM WATER RUNOFF
PURSUANT TO CHAPTE~ 236
OF THE TOWN CODE
Typical Window and Door Header
Strapping Detail Each Corner
NTB
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS RE, QUI/J3ED AND CONDITIONS OF
_ v f SOUTHOLDTOWNZBA
SOUTNOL0 TOWN PLANNING BOARD
SOUTHOLD TOWN TRUSTEES
N.Y3, DEC
AF'PRAVE? AS NOTED
ALL CONStRUCTiON SHALL MEET~E
PEO~iREMENTS OF THE CODES OF NEW
~ ~,RK STATE NOT RES~NSIBLE FOR
DESIGN OR CONSTRUCTION ER~RS,
r Il --II ]]- I ir
L -- LL L IL --
I ~ ELECTRICAL
I ~' INSPECTION REQUIRED
I " PLU,I
-i W~ JNEGTflEED
~TE~ING BEFORE C~ERIN~
I
ro~ ~w ~P~ ~s~a~ w~ ~ CERVF~~A~y
8OL~R U$~D IN WA TER
~~ ~ SUPPLY SyS~M.C]N~T
m
/
ROOF PT ,AN
LLI
CO
A1
DOOR
ErIIWIING tn. rtL
BASEMENT
FOUNDATION PLAN
Y4" = 1'-0" ~
WATER
SUPPLY
7'-9"
ANDERSEN C~7X14
CLOSET
CLOSET
CLOSET
CLOSET
BATH
TiLE
3'-7" 1%0" 1%0"
ROOM
ri
~J
Il
NL2832
42'4)"
1FLooR PI'AN
A2
SOUTH ELEVATION
'/4 "~ ~,-o,, 1 _F, AS~T ELEVATION
lA" = 1'-0"
3
SECTION VIEW
A3