Loading...
HomeMy WebLinkAbout37335-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 9/11/2012 No: 35938 Date: 9/11/2012 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: RESIDENTIAL ALTERATION 65 Ryder Farm Ln, Orient, Sec/Block/Lot: 15.-8-1.4 Filed Map No. Lot No. filed in this officed dated 37335 dated 8/7/2012 conforms substantially to the Application for Building Permit heretofore 6/18/2012 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built" conversion of existin~ barn to one family dwelling with covered entry and deck steps as applied for per ZBA #6292, dated 7/30/09. The certificate is issued to Fischer, Nancy L (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 8/20/12 R10-12-0044 37335 7/23/12 8/20/12 Joe Whitecavage /~t~ riz~( Signa(ure TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37335 Date: 8/7/2012 Permission is hereby granted to: Fischer, Nancy 38785 Route 25 Orient, NY 11957 To: "As Built", Conversion of an Accessory Structure (Barn) into a Single Family Dwelling; Kitchen, Living Room, Dining Room, 3 Bedrooms, 2 Baths, Foyer, Laundry, Decks, as applied for. At premises located at: 38785 Route 25, Orient SCTM # 473889 Sec/Block/Lot # 15.-8~ Pursuant to application dated 6/18/2012 To expire on 2/6/2014. Fees: and approved by the Building Inspector. CO - ALTERATION TO DWELLING SINGLE FAMILY DWELLiNG - ADDITION OR ALTERATION Total: $50.00 $1,402.40 $1,452.40 Building Inspector Form No. 6 TOVVN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF occUPANcy Thi~ application must be filled in by typewriter or ink and submitted to the Building Department with the follOWing: A~ For new building or new use: 1. Final survey °f Pr°petty with accurat¢'localion of all buildings, property lines, streets, and unusual natural or topographic featur6s. - 2.Final Appr°val fr°m Health DepL of water supply and aewemgcMisposal (S.9 fcwm). Approval ofok~triea[ installation from Board 6fFire Underwriters. ' 4. 'aw. om statement from plumb, or ee, rtffying that tho solder used.in system contains leas than 2/10 of 1% lead. 5. Commer~nl building, industrial building, mtfltiptc reaidenoea and similar buildings and installations, a certificate of Code ComPlianceTrom architect or engineer responsible for the building; .6. Submit planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957} don-conforming us~s, or buildings 'and "pre--existgng" land uses." 1. -Accurate survey of property showing all property lines,'streeta, building and. unusufil natural or topographic features. - · 2. A properly -.~.:mpleted application and consent to inspect signed.by the applicant. If a Certificate of Occupancy is denied, the BUilding Inspector shall state the reasons therefor in writing to the applicant. 1. Certificaie of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Akerations to dwelling , Swimmirlg pop1 $50.00~ Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00; 2. CeFtifleat¢ of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $:25 · 4. Updated Certificate of OCcupancy- $50.00 · 5. Temporary Certificate Of Occupancy - Residential $15.00:, Commercial $15.00 lew Construction: Old or Pre-existing Building: ' (check one) HOuse ]NO. ttffolk .Co. un~ Tax Map NO1000, Section abdiviai~n Street Fried Map. q- ~ j>- ApplieaaK' Undmwiter~ Approval: Final Certificate: Hamlet : __ (check one) Av~li~c nl Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY I 1971-0959 Telephone (63 I) 765-1802 Fax (631) 765-9502 ro.qer, richert~town.southo d ny us BUILDING DEPARTMENT TOWN OF' SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Dan & Nancy Fischer Address: 38785 Main Rd City: Orient St: NY Zip: 11957 Building Permit #: 37335 Section: 1 5 Block: 8 Lot: 1.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: as built DBA: Paul Burns Electric License No: 3892-e SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage Service I ph Service 3 ph Main Panel Sub Panel Transformer Disconnect Other Equipment: INVENTORY Hot Water GFCI Recpt NC Condenser Single Recpt A/C Blower Range Recpt Appliances Dryer Recpt Switches Twist Lock 5-paddle fans, 2-exhaust fans Ceiling Fixtures J~ HID Fixtures Wall Fixtures 121 Smoke Detectors Recessed Fixtures[~ CO Detectors Fluorescent Fixture ~.~ Pumps Emergency Fixturesl.~ Time Clocks Exit Fixtures [~J TVSS Notes: Inspector Signature: Date: Aug 20 2012 81-Cert Electrical Compliance Form.xls Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 BUILDING DEPARTMF_aNT TOWN OF SOUTHOLr~ Telephone (631 ) 765-1802 Fax (631 ) 765-9502 CERTIFICATION Date: Building Permit No. ~ 7ff~5 Owner: ,~'/',~ /~P~ Y L . F/ SC4/ffI~ (Please print) Plumber: ,~o-~ t~ ,~: ~-~.~ (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Sworn to before me this day of~~ , 20 Notary Public, County (Plumbers Signature) TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ [ ] ELECTRICAL (ROUGH) REMARKS: [ ] ROUGH PLBG. [ ] INSULATION ] FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION '~ ELECTRICAL (FINAL) DATE iNSPECTOR~--- r'~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ]ELECTRICAL (ROUGH) REMARKS: [ ] ROUGH PLBG. [ ]IN. iON [/] FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION ] ELECTRICAL (FINAL) DATE INSPECTOR JAMES J. DEERKOSKI P.E. 260Deer Drive Mattituck, NY 11952 (631) 774 7355 jamesdeerkoski~yahoo.com Date: August 24, 2012 To: Town of Southold Building Dept Re: Fischer 38785 Route 25 Orient, NY 11957 Permit# 37335 To Whom It May Concern: This letter certify that the conversion of an Accessory Structure into a single family dwelling at the above mentioned location has been built in conformance with all local and New York State Building Code. Also this structure has been constructed to the specifications of the submitted plans. Ox. ,C.,,Any questions feel free to call. '.,. Singerely, Jhlnes'J Deerkoski P.E. mL~~Om~,OX~ ~,~ CO .M~Va~S · FOUNDATION (1ST) ~ ! ROUGH ~G & ~ ~ PL~G STA~ E~R~ CODE ~1~/ /~ '~ ~ " I I/)~ , TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWn SOUTHOLD, NY 11971 FAX: (631) 765-9502 SOutholdTown. NorthFork. net B~ldiag Insp~or BUILDING PERMIT APPLICATION CHECKLIST Do y~m have or need It~ foil~. ~ing, before applying? Board of Health 4 sets o f Building Pisris Planning Bo~aooroval Survey V' Cheek Septic Fomt T~ Storm-Water Asses.n'aent Form APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS ;20// o. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, aecurate plot plan to scale. Fee aecording to schedule. b. Plot plan showing location of lot and of binldings on premises, relationship to adjoining premises or public streets or ~re&s, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any pta-pose what so ever until the Building inspector issues a Certificate of Occupancy. L Every builtFmg permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. lfno zoning amendments or other regulations affecting the property have been enacted in the int¢fim~ the Building inspeetot may aulhotize, in.writing, the extension of the Perrmt for an addition s~x months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to thc B uihTmg Department for the issuance of a Building permit pursuant to the Building Zone Ordinance of the Town of Senthold, Suffolk Couaty, New York, and other applicable Laws, Ordinances or Regulations, for the constxuction of builffmgs, additions, or alterations or for removal or demolition as berein described. The applicant agrees to comply with all applicable laws, ordinmcea, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. {~aatu~ of I~pticant or name, if~ corporation) (Mailing a4dress of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameorownerofpremises/~ ~CV L. ~/~t C.h~/ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer 0qame and title ot'c0rP°mte officer) Builders Lieens¢ No. Plumbers License No. Electricians License No. Other Trade's License 1. Location of land on which proposed work will he done: --%¢ ;'A.c /~,,~.., /eo,,_.g House Number Street Hamlet County T~x Map No. 1000 Section /~ Block afl Lpt // Subdivision Filed Map No. Lot, 2. State existit~g use anti occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended usc and occupancy 3. Nature of work (check which applicable): New Building Addition Repair Removal Demolition Other Work - 4. Estimated Cost Fee 5. If dwelling, number o f dwelling units If garage, number of cars Alteration (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. Ifbusincss, commercial or mixed occupancy, specify nature and extent of each type of ese. 7. Dimensions of existing stmctares, if any: Front ~'2- Rear Jif. Z. Depth Height -/~'" ~',~ ~,d~e Number of Stodes / Dimensions of same structure with alterations or additions: Front 6,.4/z-/Y,~/y'~'fB Rear Depth Height.__~ Number of Stories 8. Dimensinns of entlrc new constructinn: Front ~/Y ~)Y,d///d ~r Depth Height . Number of Stories / 11. Zone or usc district in which premises arc situated ,~_ 12. Docs proposed construction v oJatc any Zoning law, ordinance or regulation? YES__ NO v/ 13. Will lot be re-graded? YES NO ,~11 excess fill be removed from premises? YES NO 1 $ a. Is this proporty within 100 fcct of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE ~EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO v" * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If clevatinn at any point on property is at 10 feet or below, must provide topographical dam on survey. 18. Are there any covenants and restrictions with respact to this property? * YES · IF YES, PROVIDE A COPY. NO STATE OF NEW YORK) ~' 1[,13 [".'~ ' L ~ ~ Ch~.~- being duly sworn, dcpescs am:l says that (s)be is the appliceat (Name o f individfial signing contract) above named, (Contractor, Ag~at, Corporate Officer, etc.) of said owner or owners, and is duly authorlzcd to perform or have performed the said work and to make and file this application; that all statements contained in this application orc haae to the best of his knowledge and belief, and that the work will be performed in thc manner set forth in thc application filed therewith. Sworn to before me th'~ ~ . ~/ N~tary~ublic LINDA $. CARLSON S;g~a~rcdfApplicant---'~..~ Notary Public, State of New York No. 01CA6137178 ...___O~al)fied_in Suffolk County Office Location: Town Annex/First Floor, Capital One Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 Mailing Address: 53095 Main Road Rd. Box 1179 Southold, NY 11971-0959 http://southoldtown.north fork.net BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 Fax (631) 765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION REGULAR MEETING HELD JULY 30, 2009 ZBA File # 6292 - Daniel and Nancy Fischer Property Location: 38785 Route 25, Orient CTM # 1000-15-08-1.1 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated ?? _2009 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. PROPERTY FACTS/DESCRIPTION: The applicant's property contains 72,665 square feet in area and is improved wilh a single-family, two story frame dwelling, a one story frame improved barn and two accessory structures (play house and shed), as shown on a survey prepared by John T. Metzger dated April 12, 1990 and revised June 16, 2008. BASIS OF APPLICATION: Requests for Variances, based on an application to the Building Department and the Building Inspector's February 4, 2009 Notice of Disapproval concerning a proposed subdivision of property for the following reasons: (1) the proposed subdivision is not permitted with less than a minimum 40,000 square foot lot size in the R-40 District, for proposed Lots #1 and #2; (2) the existing as-built (without permits) one story structure is proposed on Lot #2 with a side yard setback at less than the code-required minimum of 15 feet (3) the existing accessory shed is less than the code required minimum of 10 feet. Note: Shed was moved to conform with side yard setback code provision upon granting of proposed subdivision and new proposed lot lines. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this applicalion on June 25, 2009, at which time written and oral evidence were presented. Based upon afl testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: · Page 2- ,luly 30, 2009 ZBA File Ct 6292 - Oaniei and Nancy Fischer Property Location: 38785 Route 25, Odent CTM # 1000-15-8-1 1 AREA VARIANCE RELIEF REQUESTED: The applicant is requesting area variances for a proposed subdivision of the existing parcel into two equal sized lots. The area variances are for a lot size of 36,333 square feet for proposed Lot #1 and a lot size of 36,332 square feet for proposed Lot #2 where the code requires a minimum of 40,000 square feet per Lot. Proposed Lot #2 will also require an area vadance for a Side Yard setback reduction with the conversion of the existing improved accessory barn structure into a principal dwelling. This existing improved accessory barn structure has a Side Yard setback of 11.4 feet where the code will require a 15.0 foot Side Yard setback. As shown on the Survey of Property prepared by John T. Melzger L.S dated April 12, 1990 and revised June 16, 2008. ADDITIONAL INFORMATION: The applicant has previously been before the board under ZBA Fil~ # 5883 requesting area variances for a similar subdivision of this same parcel and was denied relief. In response to a request for comments from the ZBA, The Town of Southold Planning Board, in a Memorandum dated May 4, 2009 addressed to the Zoning Board of Appeals states that it has inspected the site and analyzed the lots and lot sizes in the surrounding neighborhood and has concluded that it has no objection to the issuance of the requested variances under this application. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Town Law §267-b(3)(b)(3)(1). Grant of the variances will not produce an undesirable change in the character of the neighborhood or a detriment to nearby propedies. The proposed lot sizes are consistent with the existing lot sizes in the surrounding neighborhood. The side yard variance requested adjoins a Town of Southold owned Recharge Basin, which is heavily vegetated and buffers the existing improved accessory barn structure from the neighboring property to the North. 2. Town Law §267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than area variances. The existing parcel is 72,665 square feet and therefore cannot be subdivided to create two cede conforming lot sizes of 40,000 square feet each. Upon granting the approval of the lot size variances to create the subdivision, the improved existing accessory barn structure will require a Side Yard variance because it will then be interpreted as a dwelling under the code. 3. Town Law §267-b(3)(b)(3). The area variances for the two proposed lots require a 9.17% variance each, which is not substantial. The side yard variance would be 24% and not substantial when considering this Side Yard adjoins a well vegetated Recharge Basin. 4. Town Law §267-b(3)(b)(5). The difficulty to require variances for the two equal lot sizes of the proposed subdivision has not been self created because the original parcel consists of only 72,665 square feet where the code would require 80,000 square feet in this padicular case. The difficulty has been self-created with respect to the request for a Side Yard vadance for the improved existing accessory barn structure. The difficulty came when the owner improved an existing conforming accessory barn structure to a dwelling. Page 3 - July 30, 2009 ZBA File # 6292 - Daniel and Nancy Fischer Prope~ Location: 38785 Route 25, Orieut CTM # 1000-15~-1~1 5, Town Law §267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6, Town Law §267-b. Grant of the relief requested is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of the subdivision of his property, while preserVing and protecting lhe character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member Weisman, and duly carried, to GRANT the variance as applied for, as shown on the Survey of Property (1000-15-08-1,1) by John T. Metzger, dated April 12, 1990 and revised June 16, 2008. Vote of the Board: Ayes: Members Goehringer (Chair~n, we?~smaa...and Schneid/er. This Resolution was duly adopted (4-0). / /C~-rd P. Goehringer, Chairman,~//.,~009 $oulhold Town Cleft Town of Southold Erosion,Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPB~TY LOGAT~N: 8~,TJ~ ~: THE FOLLOWIN~ ACTION8 MAy REQUIRE THE 8UBMI88~ON OF A L~ GAkii~ir'u BY A D~al~e( PROFESSIONAL IN I~E ~I'ATE OF NEW YORK. $COPEOFWO~ - ]~O~OSED CON~-IIKi~CTZON IT~# / ~O~A~$Y-~-~T I Yes No (Include Total Ama of all Parcels rocatsd w~hin I Will this Pm~ct RMaIn AIl Stom~-Water Run-Off Slop~ ~g S~ Wa~r F~. and ~m~ ~1 ~s ~ ~ ~ u~ ~ ~ m~ be ~n~ned ~ghout ~ En~ ~n P~. E~g O~e In~ ~ ~ ~ ~Y~s ~al ~ any ~? 5 ~1 ~is ~on ~ulm ~ ~ ~ (5,~ S.F~) S~m F~ of G~nd Su~? ~? Is ~ ~Je~ ~ ~e ~d~ ~ ~ ~ ~: or~ffi~ ~ ~ (1~') ~ ~ a ~ ~ ~ ~ W~ ~ ~ ~ ~. ~ ~ ~.1 Su~ ~ S~p~ ~ Dlm~ ~-W~ ~ ~'AI~ OF NEW YO~ C ~ t ~ ~at~he~ 0~ ~or ~pm*m~fi~ of ~e ~er or ~, ~d ~ d~ ~d~o~d m ~o~ or ~ peffo~ ~e ~d ~ ~d m · at ~ ~rk ~ ~ ~om~ in ~e m~ ~ f~ ~ fl~e ~p~on ~ h~dfl~. S~m m b~o~ me ~; FORM - 06/10 Notary Publlc, State of New York No. 01 CA6137178 Qualified in Suffolk County /.~ Commission Expires Nov. 14, 20 P.O. ~ 11~9 TcJcpbonc ((~1) 7~1~0~ BUn ~G DEPAI~q~IENT TOWN OF 8OUTHOT.n APPLIC^TION FOR I::LECTRICAL INSPEOTION REQUESTED BY: , Name: Name: Date: JOBSITE INFORMATION: (*Indicates required information) *BRIEF DESCRIPTION OF WORK (Please Print Cleady) (Please Circle All That Apply) *Is job ready for inspection: *DO you need a Temp Certificate: ~NO Rough In ~ YES / NO *Sen~ce Size: 1 Phase *New Service: Re-mnnect Additienal Information: Temp Infonnatlen (If. needed} 3Phase Unden3round Number of Meters Change of Sen~ce PAYMENT DUE WITH ~d:~PLICATION 82q~uest ~o~ In~oecUon Fo~m PLANNING BOARD MEMBERS DONALD J. WILCENSK/ Chair WILLIAM J. CREMEHS KENNETH L. EDWARDS JAMES H. RICH III MARTIN H. SIDOR PLANNING BOARD OFFICE TOWN OF SOUTHOLD MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 June 5, 2012 Charles R. Cuddy, Esq. P.O. Box 1547 Riverhead, NY 11901 Re~ Final Approval: Standard Subdivision for Daniel Fische_r Located at 3878~ NYS Route 25, ~)ri~nt SCTM#1000-15-8-1.1 Zoning District: R-40 Dear Mr. Cuddy: The Southold Town Planning Board adopted the following resolution at a meeting held on Monday, June 4, 2012: WHEREAS, this proposal is to create a 2-lot standard subdivision on a 1.6682 acre parcel where Lot 1 is 36,333 square feet and Lot 2 is 36,332 square feet in the R-40 Zoning District; and WHEREAS, the Southold Town Zoning Board of Appeals granted approvals for Lots 1 and 2 for lot area variances and a side yard setback variance on July 30, 2009; and WHEREAS, on March 9, 2010, the Southold Town Planning Board granted Sketch Approval on the map prepared by John Metzger, L.S., dated July 15, 2009; and WHEREAS, on September 13, 2010, a Preliminary Public Hearing for the above- referenced application was held and closed; and WHEREAS, on November 15, 2010, the Southold Town Planning Board granted Conditional Preliminary Approval; and WHEREAS, on February 24, 2011, the agent submitted an application for Final Plat Approval along with the Final Application Fee in the amount of $500.00; and Fischer PaRe Two June 5, 2012 WHEREAS, on October 3, 2011, the Southold Town Planning Board reviewed the Office of the Town Engineer's comments and decided that in place of a full SWPPP the Board would require storm water calculations; and WHEREAS, on April 9, 2012, the agent met with the Planning Board at their Work Session to discuss the requested storm water calculations. The Planning Board agreed that the calculations were not necessary due to the fact that the site is already improved. Additionally, the Planning Board required a Covenant and Restriction restricting that storm water be retained on-site; and WHEREAS, on April 18, 2012, the agent submitted revised Covenants and Restrictions; and WHEREAS, on April 25, 2012, the agent submitted the required Park and Playground Fee and the Administration Fee; and WHEREAS, on May 16, 2012, the agent submitted five mylars and six paper prints which had been endorsed by the Suffolk County Department of Health Services; and WHEREAS, on May 21,2012, the Planning Board, at their Work Session, accepted the revised Covenants and Restrictions and agreed to waive the final hearing pursuant to Section 240-56 of the Southold Town Code; and WHEREAS, on May 30, 2012, the agent submitted Covenants and Restrictions recorded with the Suffolk County Clerk, Liber 12694 and Page 708; be it therefore RESOLVED, that the Southold Town Planning Board grants Final Approval, on the ma~q, ~.ntitled "Final Plan Fischer Property", dated Aori112. '[990 and last revised January 17, ~2012, prepared by John T. Metzger, Peconic Surveyors P.C., a~zes the Chairman to endorse the map. Upon endorsement of the Final Plat by the Chairman, the mylars and paper prints must be picked up at this office and the Final Plat filed with the Suffolk County Clerk by the applicant within 62 days of the date of Final Plat Approval, or such approval shall expire. Final Plat Approval shall be determined in accordance with §276 of the New York State Town Law. Final Plat is void if revised after approval. No changes, erasures, modification(s), or revisions shall be made to any Final Plat after it has been approved by the Planning Board, and such approval has been endorsed in writing on the plat, unless the said plat is first re-submitted to the Planning Board and the Planning Board approves any modifications. In the event that any such Final Plat is filed without complying with this requirement, the same shall be considered null and void, and the Planning Board shall institute proceedings to have the Final Plat stricken from the records of the Suffolk County Clerk. Fischer PaRe Three June 5,2012 If you have any questions regarding the above, please contact this office. Very truly yours, Donald J.~censki Chairman Encl. cc: Building Dept. w/map Assessors w/map ,, 3 733- BUILDING PERMIT EXAMINER CHECKLIST" *Date Submitted: 6 -~- [ ~l.~ Date Reviewed: Appheant: . /V ~ ~ ~ ~ Owner: ~ff~ ~~ 8CTM, 1000- /S -- g I, ~ Subd,wsmn: 0.~~Zone: a'~° Conforming?~ Property Address: Building Permits (Open/Expired): B? -Z / C/0 Z- , Info: BP __-Z / C/0 Z- , Info: BP -Z / C/0 Z- Single & Separate Search Required? Y or~2)Determination: REQ. Lot Size: ACT. Lot Size: REQ. Front ACT. Front REQ Side , Info: ACT. Side City: Pre COs7 BP __-Z / C/0 Z- , Info: BP__-Z / 12/0 Z- , Info: __ REQ. LOt Coy. o~o'~ ACT: Lot Cov. REQ. Rear__ PROP. Rear REQ. Height. 3~t ACT. Height. R~Z~. $o'r8 $1~5 .. /I CT Waterfront~ o(~ ~ ~ ~~ , lfy~, water body: - Panel~ '- Flood Zone: ~ BUl~ea~BluffDistance: ~DITIONAL APPROVALS ~QUI~D ~C~ ~ (¢) SI~, ~[~ O~u~V~ ~ Suffolk County Health: or N- If yes, *Bed~: ~ *Date: ~-~ff~Permit~: g 10-l~-~rown Septic: ' - If no, certification required: Y or N Received: Y or N By: ~S DEC: ea~c ~at*5 Y or~ Date: / / Permit ~: or NJ Letter - Notes: Southold Trustees: Y o~- Date: / / Permit ~: or NJ Letter - Notes: SoutholdZBA~rN-Date: 7/ff~/ 07 Permit~: -Notes: Southold Planning:~or N - Date: ~ / ¢ / ]~ Permit ~: - Notes: ~ ]d7-/2~ ~ ~ Town Landmark C of A: Y o~TE: / / *~S CODE ~omp~ance (page 2): Y or .Fee Structure: Foundation: 33 SF First Floor: I ~' ~' 0 SF Second Floor: SF Other: SF Total: [ o~-..,q',z3 SF Calculation: (2 oFo 1°a'5-3 xs ,5-o I ,,,to + Initial Fee: $ ~-O 0, o O + Additional Fee ( ): $ SFX$, + Initial Fee: $ + Additional Fee ( a4-$u~:): $ 70 ]. kO .5-0,oo 8UlkT FIZE q~70/.;l. 0 TOTAL:$ Iff`oil., '.f-o NEW YORK STATE CODE COMPLIANCE CHECICLIST C.LIMATIC/GEOGRAPHIC DI~SIGN CRITERIA: Grolmd Snow Load: ~0 Weathering: Severe__ -Frost Depth: 36"__ Design Temp: 11 __ 'Ice Shield Underlay: YE8 USE/OCCUPANCY CLASSIFICATION'. HEIOIZIT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEEREDfPRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: Y/Iq WALL ST1UI)s: Y/N CEILING JOISTS: YfN FLOOR JOISTS: YfN LUIM[BER SPECIES AND GIR_AI)E: YfN Wind Speed: 120MPH__ Seismic Design Categoryi B , Termite: M-H' Decay: S-M Flood Hazards: GIRDERS; Y/lq ROOF WINDOW AND DOOR SCHEDULE: · MISSLE TEST REQUIREMENTS: Y/N EGRESS 5.? S.F.: Y/iN LIGHT 8%: Y/N ~rENT 4 %: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: YfN (R~$¢it~c~ TOTAL COMPLIENCE7 Y/N (~TU~ TO ]PAGE ONE) MAP OF ORIENT BY THE SEA FILED OCT. 23, 1961 FILE NO. \ 3444 TOWN OF SOUTHOLD FINAL MAP REVIEWED BY ZBA SEE DECISION # ~,~ PAVED '~ --I --I'--'-Q91YQ # NOI$1O=IO =l=lS YSZ A8 aaM~llA~t~l dVlN "]¥NI.-I SURVEY OF PROPER T Y A T ORIENT TOWN OF SOUTHOLD SUFFOLK COUNTY, N. Y. 1000 - 15 - 08 - 1.1 Scale I"= 40' April 12, 1990 ._' ,., :f~/..~ 4~.~. ~.N_o,.~'~'~ ' 90- 170 SCDHS Re/.# MAP OF ORIENT N 88' 28' 00" E 107,08: . p BY- THE' LOT FILED ~)cT. 23, I;81 FILE NO. 3444 SOUTHOLD Town OF N 88' Off' 20" E c~ L 0 T NUMBERS ARE REFERENCED TO ~ SUBDIVISION- "FISCHER PROPER~'Y' FILED IN THE OFFICE OF THE SUFFOLK COUNTY CLERK. SURVEY OF PROPERTY AT ORIENT TO WN OF SOUTHOLD SUFFOLK COUNTY, N Y. lOqO - 15 - 08 - PlO L 0 T 1.1 (~ x I SI'Y FR. ,' HOUSE Sca/e: 1" = 40' July 3, 2012 oO S ~o Ted Borinq by ~¢DONALD G£OSCIENC[ II/I;Z/09 c"L )ARK BRO~N LOAM · OL ~ROWN SILT OL 18' BROWN FINE COARSE.~4ND SW [ F~£ TO COARSE SAND SW The locations of wells and cesspoo~ shown hereon are from field observations and or ~om dolo obtained ~om o/hers. Therefore lhe~ Iocdions and or exisle~ce ~ no/ gu=ranlee~ am familiar with the STANDARDS FOR APPROVAL AND CONSTRUCT/ON OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by /he conditions se/ forlh /herein and alt /he perm# to consiruc(. FEMA FLOOD ZONE A,VY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECT/ON 7~09 OF THE NEW YORK STATE EDUC~ TION LAW. EXCEPT AS PER SECTION 7~09 - SUBDI~ E. ALL CERTfF~CATION$ HEREON ARE VALID FOR THIS MAP ~ COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR IVNOEE S/GNA TURE APPEARS HEREON. ELEVAT/ONS ARE REFERENCED TO NA VD88 N,'~'~S, LI~i NO. 49618 /~ECONIC S'U~/YEYORS, P.C. [651] 765 - 5020 FX (631) 765 - 1797 P.O. BOX 909 /230 TRAVELER STREET SOUTHOLD, N.Y. 11971 90-1 TO GENERAL NOTES CONSTRUCTION NOTES: FOUNDATION NOTES: FRAMING NOTES WIND FRAMING NOTES DECK AND COVERED PORCH NOTES: PLUMBING NOTES HVAC SYSTEM NOTES ELECTRICAL NOTES: NAILING SCHEDULE ROOE _FRAMING: WALL FRAMING: FLOOR FRAMING: ~OOF SHE/ ,TFlNG: CEILING SHEATHING: WALL SHEATHING: FLOOR SHEATHING: NOTES: PLAN CONTENTS: CLIMATIC & GEOGRAPHIC DESIGN CRITERIA ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: 4' PERIMETER EDGE ZONE NOTES WALL SHEATHING REQUIREMENTS FOR WIND LOADS: NOTES NOTE; WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS . :, ' ~ SCDHS ReL # SlO-10-O004 ~ N 88' 2~' 00' E, l~,~l' I ~__ " ' ' ~ (NOT TO SCALE / ~'r o~rr. de"r ~ erm~. UTILITIES ELECTRIC TELEPHONE CA BL EVISION SEPTIC SYSTEMS PRIVATE WELLS ~.~ FEMA FLOOD. ZONE X - ELEVATIONS ARE REFERENCED TO NAVD$8 AREA = 1.6682 Acr~ Tesl Belin ~°~ ' FINAL PLAN FISCHER PROPER TY AT ORIENT TOWN OF SOUTHOLD SUFFOLK COUNTY. N. Y. Scale I;' = 40' APRIL 12, 1990 Dec. 7, 2009 Jan. /4, 2010 (trees) . Marcho~,.6, 2010 faddillons) Aug. 5~ 2010 ~revi$ions) Dec. 31~ ZOiO (~dd/I/ons) · Covenam & Re~ctlon~ /"~E ~ zP'-L~L PAGE ~._.~_~ APPROVED BY PLANNING BOAR, D TOWN OF SOUTHOLD DATE JUN O- $ ~012 SUFFOLK COUNTY DEPARTMENT OF HEALTH' SERVICES ~ HAUPP~AUGE~ N.Y. FEB ! 7 _ ROAD P~ APPROVED IN ACCORDANCE WITH BOARD OF R~V[EW DETERmINATiON DATED ~T ~ ~ ~ ~ ~ ~ ~CT TO S~ I HERESY CERTFY THAT THE WATER SUPPLYI$) AND/OR SEWAGE DISPOSAL FOR TNIS PROJECT WERE DESIGNED BY ME OR UNDER MY DIRECTION CAREFUL AND TROROUC+I STUDY'OF THE SOIL~ SITE AND GROUND R CONDITIONS ALL LOTS AS pROPOSED,-CONFOR~ TO THE SUFFOL~ Y DEPARTMENT OF HEALTH SERV CES CONSTRUCTION OF THIS DATE. FIRE DISTRICT - SCHOOL DISTRICT - ORIEN7 The locations of we/Is and cesspools shown hereon ore from field observofions end or from do/~ obtoined .from o/hers. Therefore Iheir Ioco/ion$ end or exislence Is nol guaron/eed. NYS LIC NO. 49619 s, P.C. (631) 765 - 50~0 FAX 1631) 765 - 1797 P. O. BOX 909 IZ$O TRAVELER STREET ('~i'~ I $OUTHOLD, N.Y. SCDH$, Ref ¢/: RIO-II-OOJ8 APPROVED (BARN] CROSSECTION HEX SEPTIC SYSTEM ..... ~ .~ ~ow~ o, ~o~,o,~ ....... N UTILITIES EL EC TRIC TELEPHONE CABLEVIS/ON GAS SEPTIC SYSTEMS PRIVATE II~"LLS FEMA FLOOD ZONE X ELEVATIONS ARE REFERENCED TO NAVD88 AREA = 1.6682 Acre~ 18' FISCHER PROPE/? TY ~ A T ORIENT TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. !000- 15- 08 - 1.1 Scde 17 = 40' APRIL 12, 1990 Dec. 7, 2009 JQn. /4~ 2010 (/Tees, JUNE 8~ 2011 JUL Y ~5, ~011 (revisions] CROSSECTION IMPROVED SEPTIC SYSTEM Ely. Fr. Rouse) EL, 12.5 RI o - I/, o The Iocallon$ of wells and cesspools shown hereon are from field observalions and or from data obtolned from ofhers. Therefore Iheir Iocafions and or ex/slence i$ nor guoranfeed, (EJll 765-5020 FAX (631I 765-1797 P.O. BOX 909 1250 TRAVELER STREET SOUTHOLD, N.Y. 11971 ,?~0-/ ~0 GENERAL NOTES: 1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR - LARCH, STRUCTURAL GRADE NO. 2 OR BETTER. 2. ALL SHEATHING TO BE APA RATED, STURD-I-FLOOR, EXPOSURE 1, 5/8" MIN. THICKNESS'OR AS NOTED. 3. ALL SUBFLOORING TO BE APA RATED, STURD-I-FLOOR, EXPOSURE 1, 3/4" MIN. THICKNESS.ALL EDGES OF PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND NAIL PLYWOOD SUBFLOOR TO JOISTS. 4. ALL HEADER'S 6'-0" AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS, 9'-0" AND OVER WITH TRIPLE UPRIGHTS. ALL HEADERS SHALL BE A MINIMUM OF 2) 2 x 8'S, OR AS SHOWN ON DRAWINGS. 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS AS PER N.Y.S. CODE, OR AS NOTED, @ 8'-0" D.C. MINIMUM. PROVIDE 2" SPACE FOR AIR CIRCULATION IN ROOFS. 6. DOUBLE FRAMING AROUND ALL OPENINGS (stairs, skylights, chimneys, etc.), OR AS NOTED ON DWGS. 7. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITION, OR AS NOTED ON DWGS. Nailing Zones for Roof Sheathing in 120 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH MPH Peak Gust Wind Zone RATED GALVANIZED METAL CONNECTORS BY "TECO" OR -- -- APPROVED EQUAL. 9. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. BUILDING Rancid,,, r 6 o.c. r ,.o.c. I ' o.c. r CODE AS A MINIMUM. ALL 2 x 6 STUDS SHALL RECEIVE 5) 1Od Nailing Raqulmmente for 120 MPN, 3 Beg. Peak Gust, NAILS AT SILL AND PLATE. ALL EXTERIOR NAILS SHALL BE ~"~lckRoof Bheathlag with 8d Common Nails GALVANIZED. Roof Sheathing Nailing Details 10. PLYWOOD SHEATHING TO BE NAILED WITH 8d @ 4" O.C EXTE?.R EDGES AND 6a @ 2 D.C. INTEmEDIATE. 11. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING AND WATER-PROOFING.. 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUDWITH GALVANIZED HURRICANE TYPE CONNECTORS BY "TECO" OR APPROVED EQUAL. FOR TIMBER PILE FOUNDATIONS, PROVIDE HUIL~CANE CLIPS AT ALL PERIMETER JOISTS TO GIRDER CONNECTIONS. 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA PACIFIC GPI SERIES WOOD I-BEAMS AND LVL PRODUCTS OR EQUAL. ALL JOIST GIRDERS AND HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS. WEB STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND BEARING POINTS AT A MINIMUM. A SINGLE 1 3/4" LVL RIM JOIST SHALL BE REQUIRED AT FLOOR PERIMETERS. HANDLING, STORAGE, AND ERECTION OF COMPONENTS SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS. 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" DIA. GALVANIZED MACHINE BOLTS @ 12" O.C. WINDOWS - GLAZED OPENING FOR NEW CONSTRUCTION, EXTERIOR WINDOWS MUST BE PROTECTED VIA GLAZING MEETING THE LARGE MISSILE TEST CERTIFICATION OF ZONE II ASTM E 1886-97 AND ASTM E 1996-99 OR VIA STRUCTURAL SHUTTERS WITH ATTACHMENT HARDWARE PROVIDED. NEW STRUCTURES LOCATED WITHIN ONE (1) MILE OF THE MEAN HIGH WATER MUST HAVE GLAZING CONFORMING TO WIND ZONE III, MISSILES DEFINED IN PARAGRAPH 6 OF ASTM E 1996-99. GLAZING CONFORMING TO WIND ZONE II, MISSILES CAN BE USED AT A DISTANCE GREATER THAN ONE MILE OF THE COASTLINE. Table 3.1 Nailing Schedule (Woed Framed Construction Manual 1995 BBC High Wind Edi~n, Page 110) JolrdDesedption ] NumberofNails r NailSpadng ROOF NAILING Rafter to Top Plate (Toe -nailed} Ceiling Joist to Top Plate (toe -nailed) Ceding Jaist to Pamllai Rafter (Face -nailed) Ceiling Joist Laps Over Par~tices (Face -nailed} Collar Tie to Rafter {Toe-nailed) Blocking to Rafter (toe nailed) Rim Board to Rafter (End Nailed) WALL FRAMING :4-8d 4-8d · 16d 2-1~d 2-8d 2 - 16d Top Plate to Top Plate (Face -nailnd) Top Plates at Intemectlons (Face -nailed) Stud to Stud (Face -nailed) Header to Header (Face -nailed) Top or Bottom Plate to Sted (End Nailed) 2- 16d (1) 4-16d 2- 16d 16d 2-16d 3 - 16d 4-16d permit per jaist each lap each perUe each end each end per fcet joists - each aide 24' o.c. 16" c.c. along edges par 2x4 stud per 2x6 sted per 2x8 stud Bottom Rate to Floor Joist, Band Joist, End joist or Bloc, king (Tce-nallad) 2 - 16d (1,2) per foot FLOOR FR,~IING Joist to Bill, Top Plate or Girder ('roe -nailed) :.~ 4 - 8d per Joist Bridging to Joist (toe-nailed) f 2 - 8d each end Blocking to Joist (too-nailed) 2- 8d each end Blacking to Bill or Top Plate (Toe-nailed) 3 - t 6d each block Ledger Strip to Beam (Face-nailed) 3 - 16d each joist Joist on Ledger to Beam (toe-nalted) 3 - 8d par jobt Band Joist to Joist (End-nailnd) 3-16d per jofst Band Joist to Sill or Top Plate (Too-nailed) 2 - 16d (1) per fcet ROOF SHEATHING Structural Parole 8d (Detail shoot CEILING SHEATHIN ,Gypsum Waillx~rd ftd ceaiers I 7" edge / 10"field WALL SNEATHINI Structural Panels Gypsum Wallboard 8d 8" edge / t 2" field 5d coolam 7" edge / 10" field FLOOR SHEATHING Structural Panels 8d t' o.r less 6" edge / 12" field (1) Nailing r~,',lremenla are based on wall shaathlng nailed 6 co-center at the panel edge. If wll shaathlng Is nailed 3 on-coMer at the panel edge to obtain higher ahaar oapaaitlas, nailing requirements thr structural membom shall be doubled, or altemate connectom, such as shear plates, shall be used to malotela load path. (2) When 1,'edl sheathing lo continuous over connected membam, the tebulai~ number of nails shall be pen~lfted to be reduced to 1 - t 6d nail per foot. SIMPSON L~TA~6 STRN~ RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTE~ 236 OF THE TOWN CODE Typical Window and Door Header Strapping Detail Each Corner NTB COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS RE, QUI/J3ED AND CONDITIONS OF _ v f SOUTHOLDTOWNZBA SOUTNOL0 TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y3, DEC AF'PRAVE? AS NOTED ALL CONStRUCTiON SHALL MEET~E PEO~iREMENTS OF THE CODES OF NEW ~ ~,RK STATE NOT RES~NSIBLE FOR DESIGN OR CONSTRUCTION ER~RS, r Il --II ]]- I ir L -- LL L IL -- I ~ ELECTRICAL I ~' INSPECTION REQUIRED I " PLU,I -i W~ JNEGTflEED ~TE~ING BEFORE C~ERIN~ I ro~ ~w ~P~ ~s~a~ w~ ~ CERVF~~A~y 8OL~R U$~D IN WA TER ~~ ~ SUPPLY SyS~M.C]N~T m / ROOF PT ,AN LLI CO A1 DOOR ErIIWIING tn. rtL BASEMENT FOUNDATION PLAN Y4" = 1'-0" ~ WATER SUPPLY 7'-9" ANDERSEN C~7X14 CLOSET CLOSET CLOSET CLOSET BATH TiLE 3'-7" 1%0" 1%0" ROOM ri ~J Il NL2832 42'4)" 1FLooR PI'AN A2 SOUTH ELEVATION '/4 "~ ~,-o,, 1 _F, AS~T ELEVATION lA" = 1'-0" 3 SECTION VIEW A3