Loading...
HomeMy WebLinkAbout37337-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 7/3/2012 No: 35791 Date: 7/3/2012 THIS CERTIFIES that the building ALTERATION Location of Property: 760 OLD PASTURE ROAD CUTCHOGUE, SCTM #: 473889 Sec/Block/Lot: 103.-11-20 Subdivision: Filed Map No. conforms substantially to the Application for Building Permit heretofore 3/8/2010 pursuant to which Building Permit No. Lot No. filed in this officed dated 37337 dated 6/29/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: dormer alteration and deck addition to an existing one family dwelling as applied for. The certificate is issued to THOMAS & ISABEL WACKER (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED ~Sig~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37337 Date: 6/29/2012 Permission is hereby granted to: THOMAS & ISABEL WACKER 600 6TH STREET BROOKLYN, NY 11215-3702 mo~ DORMER ALTERATION TO AN EXISTING DWELLING AS APPLIED FOR.REPLACES EXPIRED B.P. # 35396 At premises located at: 760 OLD PASTURE ROAD CUTCHOGUE SCTM # 473889 Sec/Block/Lot # 103.-11-20 Pursuant to application dated To expire on 12/29/2013. Fees: 3/8/2 010 and approved by the Building Inspector. PERMIT RENEWAL CO - ADDITION TO DWELLING Total: $176.00 $50.00 $226.00 (THIS FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35396 Z Date MARCH 16, 2010 Permission is hereby granted to: I & T WACKER 760 OLD PASTURE RD CUTCHOGUE,NY 11935 for : DORMER ALTERATION TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 760 OLD PASTURE RD CUTCHOGUE County Tax ~ap No. 473889 Section 103 Block 0011 Lot No. 020 pursuant to application dated MARCH 8, 2010 and approved by the Building Inspector to expire on SEPTEMBER 16, 2011. Fee $ 200.00 Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF $OUTI'IOLD BUILDING DEPARTMENT TOWN HALl, 765-1g02 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new bniidiug or new use: Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. ofwat~ supply and sewerage-disposal (S-9 form). 3, Approval ofeloctrical installation ~om Board of Fire Underwrlt~ra. 4, Swum ,~tat~ment fi'om plumber cea'tifying that the solder used in syst~.nn contains less than 2/10 of I% lead. 5. C. ommercial building, industrial building, multiple residenc~ and similar buildings and installations, a ccrtii]cate of Code Compliance £rom architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed sit~ plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and unusual natu~-al or topographic fealnres. 2. A properly completed application and consent to inspoct signed by thc applicant. If a Certiiicalc of Occupancy is denJ~l, the Building Inspector shall state the reasons therefor in writing to tile applicmlt. C. Fees I. Certificate of Occupancy - New dwelling $50.00, Additior~ tO dwolling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to acce.~o~ building $50.00, ~usinesses $50.00. 2. Cer~ificata of Occupaney on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate o f Occupancy - Rcsidgnlial $15.00, (;ommercial $1 $.00 New Construction: Lo(:atiou ofProporly: ~.~ (~_0 House No. Owner or Owner~ of Property'..--~ Suffolk County Tax Map No 1000, Section Subdivision -- Dale. Old or Pr~:-¢xisting Building: ~ St~t to3 (check one) Hamlet Health Dept. Approval: ~ ( ~ Planning Board Approval: ~ I ~ ~'~ Request for: T~nnporary Certificate Fee Suh~niHcd; $ _~"C~~' Block CDC) 11 Lo, C3 0 Filed Map. ~ Lot: __ ~ Applicant: ~ ~ld, ~'~.~-'7oc_ ~'OIL ~Oe~ Und~rite~ Approval: - '~ Final C~atificatc: ~ (check oac) TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. ] F~NDATION 2ND [ ]INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ] FIRE RESISTANT COflSTRUCTION [ ] I:IREI~SISTANTPF. NETRATIOfl TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ! RO~UG/H PLBG- [ ~"INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT FENETRATION DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPTi 765-1802 INSPECTION [/~FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] FlOUGH PLBG. [ ]INSULATION [ ]FINAL [ ]fiRE SAFETY I.S~ECn0. ]FIRE IIESlSTAHT PENETRATION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]F~NDATION2ND [ ]INSULATION [,/] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE INSPECTOR ~ /-'~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING/STRAPPING [ ]FIREPLACE & CHIMNEY ROUGH PLBG. INSULATION ~']/FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSll~UCTION[ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE 7' ~ ~- / ~ INSPECTOR FOUNDATION (1ST) · ROUGH ~O & PL~G ~S~ON PER N. Y. STATE E~R~ CODE .tWN OF SOUTHOLD 3UILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined ~/~ ,20 Approved Disapproved Expiration q//3 , 20 // PERMIT NO. ff ~3 ? L BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. ~,~ Trustees ~/~ Contact: Mail to: ~.4Q~IRb~IY~ Phone: Iq'-I p Cotdi tO'-/ qs'8 '7  . Building Inspector ~--~['"'~ ,, ~nta //~PPLICATION FOR BUILDING PERMIT Date a -x4. /3 ,20 ['~~t..,.~ / INSTRUCTIONS ..... ~p~lytff/y,,~fi)l~d" ~ ob~yl~t~yapa,,e,~writer or in ink and submitted to the Building Inspector with4 sets of b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the i~suance of a Building Permit pursuant to the Building Zone Ordinance of the Town o.f Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signa~re of applicam or name, if a co~oration) (Mailing ad.ess of applic~t) State whe~er applic~t is owner, lessee, agent, ~chitect, en~neer, general contractor, elec~ci~, plmber or builder N~eofo~erofpremises [X~g~ ~ ~ ~ (As on the t~ roll or laest deed) If applic~t is a co~oraion, si~amre of duly authorized ~me ~d title of co.orate officer) Builders License No. ~47 [ ~ Plumbers LicenseNo. ElectficiansLicenseNo. Other Trade's License No. 1. Location of land on which proposed work will be done: _ Hous~ Number Street Hamlet County Tax Map No. 1000 Section [ 0 3 Block [ ( Subdivision Filed Map No. (Name) Lot Lot State existing use and occupancy of premises and intended use and occupancy of proposed coRstruction: a. Existing use and occupancy ~ ] (k] F_M.,E. ~D'kl t--~ b. Intended use and occupancy ~llk~(~'~_, ~t~A-WItL,~ 3. Nature of work (check which applicable): New Building Repair Removal Estimated Cost If dwelling, number of dwelling units If garage, number of cars Addition Alteration Demolition Other Work Fee (Description) (To be paid on filing this application) Number of dwelling units on each floor /kd tax-. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front ,~6~ CiD [~ Rear Height r'L,~- Ou Number of Stories ~ y'~.. Dimensions of same structure with alterations or additions: Front Depth Depth_ Height Number of Stories Dimensions of entire new constru , t Height Sizeoflot: Front Q.O[~0~ t' ~5/),~ Rear ,3 ~-~.O6 Depth '2"Z~c',2'g'~ I(0.o~ 10. Date of Purchase ~)IEF--' ?.-00~ Name of Former Owner 11. Zone or use district in which premises are situated ~P,,~[ 0 t~x3T ~A4--~ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO V 13. Will lot be re-graded? YES NO v/ Will excess fill be removed from premises? YES NO V -- : 0c, O 14. Names of Owner of premises ~O hrC. ff..~-q~ Address Nme of Architect Address Phone No Nme of Contractor ~ ~- /~ Address ~0~7 PhoneNo. 15 a. Is this prope~y within 100 feet cfa tidal wetland or a freshwater wetland? *YES * IF YES, SOUTHOLD TO~ TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this prope~y within 300 feet cfa tidal wetted? * YES ~ NO__ ' * IF YES, D.E.C. PERMITS MAY BE REQUIRED. ~ ~ 16. Provide su~ey, to scale, with accurate foundation plan and distances to prope~y lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) CONNIE 8. 8UNCp, S S: Notaq/Public, State of New ¥o r~ No. 01806185050 COUNTY OF ,~'(,.) [~LJ~... Ouafifed n Suffolk Couet,j Corem ss on Expires April 14, 20/~ ?~"'~ ¢~_"[-D O"~,.~O{¢,~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and beliefi and that the work will be performed in the manner set forth in the application filed therewith. Sworq tO before me thins/,x ~, _ 8--1L~ day of ~'1 'k.Cv[ C~ 2Q~.)__ Notau Public Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 February 17, 2010 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Ms. Joan Chambers Environment East, Inc. 2885 Indian Neck Lane P.O. Box 197 Peconic, NY 11958-0197 RE: THOMAS & ISABEL WACKER 760 OLD PASTURE RD., CUTCHOGUE SCTM#103-11-20 Dear Ms. Chambers: The Southold Town Board of Trustees reviewed the survey prepared by Nathan Taft Corwin III last revised February 1, 2010 and determined the proposed increase in the size of two roof dormers on the existing dwelling to be out of the Wetland jurisdiction under Chapter 275 of the Town Wetland Code and Chapter 111 of the Town Code. Therefore, in accordance with the current Wetlands Code (Chapter 275) and the Coastal Erosion Hazard Area (Chapter 111 ) no permit is required. Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal and/or freshwater:~atlands jurisdictional boundary or seaward of the coast~f~.~,:osion hazard area as indicated ~ove, or within 100' landward from the top of the bluff andi0r wetlands jurisdictional boundary, without further authorization from the Southold Town Board of Trustees pursuant to Chapter 275 and/or Chapter 111 of the Town Code. It is your responsibility to ensure that all necessary best management practices are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction and Coastal Erosion Hazard Area, which may result from your project. This determination is not a determination from any other agency. If you have any further questions, please do not hesitate to call. Since[ely, ~/1' I ~jJ. Do herty,~n?'-/~ Board of Trustees JMD:lms New York State Department of Environmental Conservation Division of Environmental Permits, Region 1 SUNY @ Stony Brook 50 Circle Road, Stony Brook, NY 11790-3409 Phone: (631) 444-0365 · Fax: (631) 444-0300 Webslte: www.dec.ny.gov February 19, 2010 Mr. Tom Wacker 600 6~h St. Brooklyn, N.Y. 11215 LETTER OF NO JURISDICTION TIDAL WETLANDS ACT Alexander B. Grannis Commissioner Re: Application #1-4738-03954/00001 760 Old Pasture Rd., Cutchogue, N.Y. SCTM# 1000-103-11-20 Dear Mr. Wacker, Based on the information you have submitted, the Department of Environmental Conservation has determined that the property landward of the 10 foot elevation contour as shown on the survey prepared by Nathan Taft Corwin Ill, dated 12/2/09, is beyond Tidal Wetlands Act (Article 25) jurisdiction. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permiL It is your responsibility to ensure that all precautions are taken to prevent any sedime.n.t.a~n or other alteration or disturbance to the ground s~dace or vegetation within Arti~25 jurisdiction which may reSult from your project. S'[~ch precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20, wide construction area) or erecting a temporary fence, barrier, or hale bay berth. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. · SlPe~rely, / ~ f LauraScovazzo ?/ ~ Permit Administrator CC: Environment East, Inc., MHP, File 'Southold Eros;on, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: $.C.T.M. ~ THE FOLLOWING ACTIOKS MAY REQUIRE THE 81/~_u_!~!~_ _-_ OF A District 8~lon ~ I ~ &TORI~A~ ~N DRAINAGE AND EROSION CONTROL PLAH Bh)ckL~" CERTIFIED BY A ESIGN RO ESSIONAL THE 8TATE OF EW Item Number: (NOTE: A Check Malt (~') for each Qoastlon Is Requtred for a Comp[els Appllcellon) Yes No Will this Project Retain All Storm-Wathr Run-Off Genemisd by a Two (2') Inch Rainisll on Site? 0~is item will In~lude all raft-off created by site cleating and/or construction acitvitles as well as all Site Improvements and the permanent croedoa of Impengx~s surfaces.) Does the Sits Plan end/or Survey Show All Proposed Dralnege Structures Indicating Size & Location? This Item shall Include all Proposed Grade Changes and Slopes Contro#ing Suffaee WatsrFIowi Witi thts Project Reguim any Land Filling, Grading er Exeavaiton where there is a change ts the Natural ~ Existing Grade Isvolvlng mom than 200 Cuble Yards of Mal~tal wlthln any Pamal? Will this Appllee~<)n Regulm Lend Dtska~ng Acitvtiiss Eecempesstng an Ama in Excess of r~ Five Thousand (5,000) Square Feet ct' Graond Surface? Is them a Natural Water Coume Running through the Site? ~ Is this Project within the Trustees juitsdicfion or within Ore Hundred (1~0') ~ of a Wetland or Beach? Will there be Site preparation en Existing Grade Slopes which Exceed Fiiteen (15) feel of Vertical Rise to ~ O~e Hundred (100') of Hodzcetsl Distance? Will Driveways, Pagdng Areas or other Impen~ous Surfaces ha Sloped to Direct Storm-Water Run-Off r"~ into and~or in the direction of a Town fight-of-way? Will this Project Require the Placement of Material, Removal of Vegetation and/or the Conslructio~ of any Item Within the Town Right-of-Way or Road Shoulder Area? (Thts Item will NOT Include the instillation of Driveway Aprons.) Will this Project Require Site Pmparatien within the One Hundred (100) Year Floodplain of any Watercoume? r~ NOTE: If Any Answer 1o Questions One through Nine Is Answered wIth s Cheok Mank th the Box, a Storm-Water, Grading, Draioeg~ & Erosion Control Plan Is Required and Must be Submitted for Review Prior to tssuanoe of Any Building Perm/il EXEMPTION: Yes No Does this project meet the minimum standards for ctssclf~a6~n as an Agdcuffural Note: If You Answered Yes to this Que~=flon, s Storm-Water, Grading, Drainage & Erosion Control Plan Is NOT Requlredl STATE OFNEWYORK, ~, ,~0._/~ ('/~ v-~COUNTY OF .....~..L~ ............ SS , "'~' .... i~ of ~du~'~'~;~ ................. being duly sworn, dcpos~ and says that he/sbe is the applicant £or Permit~ And that he/she is the , CON,lIE O BUNCH NotarY Public, State of New Y0rg ......................................... ::'?"- ........ ~ .............................................. .No:GtgU~.l,gS§Sfl .................. Ioof, Conlracim',~lmt, Caxpomie office~, sic.) Oua!ified in. Suff01lI.Co?~/c~ ,an /o rep=e.ti vcofthe O e ofO e . antho zed to pe o moag l o 5 'g ] l rild o make and file this application; that all statements conlained in this application are true to the best of his knowledge and belie~ and that the work will be performed in the manner set forth in the application fried herewith. Sworn to before me this; ........... ....................... .................. ......................... ......... ...... ................ FORM - 06107 Town Hall Anncx 5~S75 M~in Read P.O. Box 1179 Souchold, NY 11971.-~J 59 BUILDING DEPARTMENT · TOWN OF SOUTHOLD APPLICATION FOR FU=CTRICAL INS~F:CTION tREQUESTED BY: Company Name: ~lame: Date: ~-- 20 -16 License No.: ~,ddress: Phone No.: JOBSITE INFORMATION: *Name: *Address: *Cross Street: *Phone No.: Permit No.: Tax Map District: (*Indicates required information) 73 - 7q7q 1000 Section: [O ~ Blcck: d)O II *BRIEF DESCRIPTION OF WORK (Please Print Clearly) (Please Circle All That Apply) *Is job ready for inspection: *Do you need a Temp Certificate: Temp Information (If needed~ *Service Size: I Phase *New Service: Re-connect Additional Information: Lot: -I 3Phase 100 YES / NO Final YES ~) 150 200 300 350 400 Other Underground Number of Meters Change of Service Overhead PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form Environment East, Inc. 2885 Indian Neck Lane P.O. Box 197 Peconic, New York 11958-0197 631-734-7474 Fax: 631-734-5812 Concerning Permit # 35396 Wacker Residence 760 Otd Pasture Rd. Cutchogue Please find attached ptans of the front entry stoop for this residence. Thank-you, Joan Chambers Environment East, Inc. 2885 Indian Neck Lane P.O. Box 197 Peconic, New York 11958-0197 631-734-7474 Fax: 631-734-5812 Wacker Residence Permit # 35396 Cutchogue May 19, 2010 We have changed the original plans: substituting an Anderson FWGD 1110611-3 for the 6'-0" slid. gl. dr. and window shown on the original plans. Attached are the revised elevation and first floor plan. Thank-you,~ Joan Cha re~]~ Southold Town Building Department P.O. Box 1179 54375 Main Road Southold, New York 11971 (631) 765-1802 Parcel 1D: 103.-11-20 Permit #: 35396 Permit Date: 3/16/2010 Expiration Date: 9/16/2011 BUILDING PERMIT RENEWAL LETTER Dated: 6/5/2012 Applicant: Location: Work Description: THOMAS & ISABEL WACKER 760 OLD PASTURE ROAD CUTCHOGUE ALTERATION DORMER ALTERATION TO AN EXISTING DWELLiNG AS APPLIED FOR A FEE OF $176.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Address: THOMAS & ISABEL WACKER 600 6TH STREET BROOKLYN, NY 11215-3702 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All work on the project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. FOR SUCH USE BY STATE LAND TITLE ASSOCIATI ~No. 50467 I4rICICHAM Nathan Taft Corwin III Land Surveyor Title Surveys -- Subdivisions -- Site Plans -- Construction Layout PHONE (631)727-2090 Fax (631)727-1727 UNAUTHORIZED ALTERATION OR AODiTION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED. AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. AND TO THE ASSIGNEES 0~' THE LENDING INSTI-- iF__ fi o ~ REScheck Software Version 4.2.0 Compliance Certificate ALL CONS'~. MEETTHE REQU?, ,,H~:_..~Z~._.. { ..~?.~ RESIDEN~DESOF rL~;,: o~.A~E.NOTFY .... ;:: .,' , ,,:7" Project Title: WACKER NEW ..... ~ .... 765-1802 8A!.] '~"~,., ..... 4~ i,i FOR '":!,= Energy Coda: 2007 New York Energy Consen~ation Construction Code Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 9% Heating Degree Days: 5750 Constmction Site: 760 OLD PASTURE RD, CUTCHOGUE, NY Compliance: '13.9% Better Than Code FOLLOWING FO;:i FOLJREiD CC ;CRfT~E 2. ROUGH - F~?LT;(~ & P_U ?lNG 3. !NSULAT~CN 4. FINAL - COHS' Ri '3];C'N k. iUST ~ner/Agent: Desi~r/~]~E F.'q ALL CON~TRU.,,IOh 3-t'.~[.L L~x~_ THE UNDERWRrT? CERTIFICATE REQUIREMENTS 0~ T).E:~. ,"'"~' OK.. NEW FOR Maximum UA: 144 Your UA: 124 Ceiling 1: Flat Ceiling or Scissor Truss i~'t/ OR 165 Ceiling 2: Flat Ceiling or Scissor Truss ~ 165 Ceiling 3: Flat CeilingorScissorTnJssUS1'' ISUNLAWFUL 31 Ceiling 4: Flat Ceiling or Scissor TrUSSr, ¢~ ,~ ~, '~ 31 Ceiling 5: Cathedral Ceiling (no attic) t, '.' Ii HOUT CERTIF!OATE 21.0 0.0 8 21.0 0,0 8 21.0 0.0 1 21.0 0.0 1 21.0 0.0 2 Ceiling 6: Cathedral Ceiling (no attic)~,. ,,- ,~.,,..~ 49 21.0 0.0 2 Ceiling 7: Cathedral Ceiling (no attic) ~.i' t~' --' V '.--,"~'~,' ~'1 F';,:"~,.,'i 49 21.0 0.0 2 Ceiling 8: Cathedral Ceiling (no attic) 49 21.0 0,0 2 Wall 1: Wood Frame, 16" c.c. 121 15.0 0.0 8 Window 1: Wood Frame:Single Pane 13 0.490 6 Wall 2: Wood Frame, 16" C.C. 171 15.0 0.0 11 Window 2: Wood Frame:Double Pane with Low-E 15 0,280 4 Window 3: Wood Frame:Double Pane with Low-E 15 0.280 4 Wall 3: Wood Frame, 16" o,c. 88 15.0 0,0 7 Wall 4: Wood Frame, 16" C.C. 121 15.0 0.0 9 Wall 5: Wood Frame, 16" c.c. 121 15.0 0.0 8 Window 4: Wood Frame:Single Pane 13 0,490 6 Wall 6: Wood Frame, 16" o,c. 171 15.0 0.0 11 Window 5: Wood Frame:Double Pane with Low-E 15 0.280 4 Window 6: Wood Frame:Double Pane with Low-E 15 0.280 4 Wall 7: Wood Frame, 16" C.C. 88 15,0 0.0 7 Wall 8: Wood Frame, 16" c.c. 121 15.0 0.0 9 The proposed building represented in this document is consistent wit~.tt~l~lildin~s, f43ecifications, and other calculations submitted with this permit application. The proposed systems have been~'~si~_ ~~'Y, ork Energy Conservation Construction Code requirements. When a Registered Design Professional has,l~d' sig~e~ t~¢~[,'Jhey ara attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or spavin ~omCian'(~'~4th this Code. Name - Title Sig nai'~r~ Date Project Title: WACKER RESIDENCE Report date: 03/03/10 Data fllename: Untitled.rck Page 1 of 1 38'-10' 2-3/8' X 9" ST. FL. PL. W/2-2X10 HEADER FWGD 1110611-3 EXIST. DIN. RM. F_XJST. ENTRY NO CHANGES EXJST. KITCHEN NO CHANGES EXIST. MUDRM. NO CHANGES WACKER RESIDENCE FIRST FLOOR PLAN ENVIRONMENT EAST INC 1/4" = 1'~)" 3.1.10 REV. 5.17.10 EXIST. CLOSET NO CHANGES EXIST. T~VO CAR GARAGE NO CHANGES 2-3/8" X 9' ST. FL PL WI 2-2X10 HEADER FWGD 1110611-3 EXIST. SUNROOM NO CHANGES EXIST. CHIMNEY (NO CHANGES) V _ _ ~ ~CEDAP. SHINGLES TO MATCH EXJST.. 2 -ANDER ~ WDH 304~ ~4-1/8" X ~ /8' I~O. i . - F__XIST. ASPHALT SHINGLES , ,~'/' ~'~,. NEW DORMER 2 - ANDEP~ I WDH 3~ ~1~' ~ -7~' ~O. WACKER RESIDENCE REVISED SOUTH ELEVATION ENVIRONMENT EAST INC 1/4" = 1"0" 4.15.10 ES TO MATCH F--XJST. ~J~KE D~OARD ~ TO MATCH EXIST. WACKER RESIDENCE FRONT STOOP 1/4' - 1'-0' 12.13.10 ;' TALL MASONRY WALL ~SONRY FTG. TO 3'-~ BELOW GRADE r CONC. BL. W~LL FACED WITH STONE. ALL nn~l~-rp ;,--,~, DATE: ......... · ,v,~ SHALL - MEET THE E:.Q;J.:. !: 'ENTS OF THE FEE:.~q.~.. _~. CODES OF NE. "" ' ~ ~,,;(oTATE, NOTIFY BU;LO'"q': P:iF~.R~ENT AT -.~:~t.,[ 765-1802 8 AM T'> ' ~ ~ *r.~ FOR THE 1. FOUNDATION FOR POURED ';:' ~-~,~ ,;t~' 2. ROUGH - FR~,r,.;,'~G & FLU~BiNG 3. INSULATION 4. FINAL - CONSTRUCTION MUST ALL CONSTRUCTION SHALL MEET THE UNOERWR~RS CE~FICATE REQUIREMENTS OF THE COUES OF NEW ~a~lIDcn, . YO~,STAT~ NOT ~SPONS BI.E FOR ~,¥1T~-,~.. ~.;EF(I'IFtCATE OF CCC, !FANCY PROJECT NAME: wAc~ TOM & ISAJ~EL PROJECT LOCATION: 760 OLD PASTURE RD. CUTCHOGUE 1. USE & OCCUPANCY: SINGLE FAMILY DETACHED 2. HEIGHT OF NEW CONSTRUCTION: SQ. FT. OF NEW CONSTRUCTION: ~ SQ. ~ X 2 = 64 8CLFT. 3. TYPE OF CONSTRUCTION: WOOD FRAME 4. DESIGN CRITERIA - PRESCRIPTIVE DESIGN AS PER AF&PA WOOD FRAME CONSTRUCTION MANUAL 5. FRAMING ELEMENTS AS SPECIFIED ON PLANS LUMBER SPECIES: #2 OR b= ~ I=R DOUGLAS FIR FOR FRAMING MEMBERS #1 S. YELLOW PINE (ACQ) IN CONTACT WI GRADE 1/2' CDX PLYWD. ROOF & WALL SHEATHING 3/4' CDX PLYWD. SUBFLOOR SIDING AS SPECIFIED ON PLANS DECKING AS SPECIFIED ON PLANS 6. DESIGN LOAD CALCULATIONS MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS DECKS (IN POUNDS PER SQUARE FT.) 40 A~TlCS WITHOUT STORAGE 10 ATtiCS WITH STORAGE 20 SLEEPING ROOMS 30 CRITERIA FOR CALCULATION OF DEAD LOAD WILL BE ACTUAL WEIGHTS OF MATERIALS REFERENCED TO ~1~ ARCHITECTURAL GRAPHIC STANDARDS. SNOW LOAD IS CALCULATED AS 30 LBS PER SQ. FT. SEISMIC CONSIDERATIONS: THIS STRUCTURE WILL CONFORM TO CODE SECTION R301.2.2.3 IN THAT ANCHORED STONE AND MASONRY VENEER SHALL BE LIMFFED TO THE FIRST STORY & NOT EXCEED 5' IN THICKNESS. THIS STRUCTURE WILL CONFORM TO CODE SECTION R301,2.2.4 IN THAT AVERAGE DEAD LOADS WILL NOT EXCEED 15 PSF ROOFS & CEILINGS 10 PSF FLOORS 15 PSF WOOD FRAME WALLS THIS DWELLING IS LOCATED IN DESIGN CATAGORY 'C' SO IS EXCEMPT FROM FURTHER REQUIREMENTS OF THE SEISMIC CODE. EXPOSURE & UPLIFT CATAGORY IS 'C' - URBAN AND SUBURBAN AREAS. 7. SEE ATTACHED WINDOW & DOOR SCHEDULE 8. LOAD PATHS FROM ROOF TO FOUNDATION WILL BE AS DESCRIBED ON SECTION. 9. NAILING SCHEDULE: JOIST TO SILL OR GIRDER - 3 ~D TOP PLATE TO STUD 2 - 16D BUILT UP HEADERS 16D ~ 16" O.C. EA. SIDE CEIL. JOISTS TO PLATE 3 - 8D HEADER TO STUD 4 - 8D CEIL. JOISTS TO RAFTERS 3 - 10D RAFTER TO PLATE 2 - 16D ROOF RAP I ~RS TO RIDGE,VALLEY OR HIP RAFTERS 4 - 16D COLLAR TIES TO RAFTERS 3 - 8D 1/2' PLYWD ROOF SHEATH. 6 ~D (12 FIELD) 1/2" PLYWD FLOOR SHEATH 6 - 6D (12 FIELD) 1/2" PLYWD WALL SHEATH 6 - 6D (12 FIELD) WIND LOAD CONNECTIONS RAFTER TO WALL CONNECTORS WILL BE "SIMPSON STRONG TIE MODEL # H8' W/ 10-10D X 1-1/2" FASTENERS OR EQUAL. ~ CONNECTORS WILL BE "SIMPSON STRONG TIE MODEL #RPS4' W/ ~8D X 1-1/2" FASTENERS OR EQUAL. 10 MEANS OF EGRESS: THIS STRUCTURE WILL CONFORM TO EGRESS REQUIREMENTS AS DETAILED IN SECTION R310 AND EGRESS IS NOTED ON ATFACHED FLOOR PLANS. 11, PLUMBING RISER DIAGRAM-NoT~-No ~LTERA~ON TO E~ST. I~UMBING. 12. LOCATIONS OF FIRE ALARMS ARE NOTED ON ATFACHED PLANS. 13 TRUSS CERTIFICATIONS ARE A~ACHED IF REQUIRED. 14 ENERGY CODE CALCULATIONS ARE DONE BY "RESCHECiC SOFTWARE - SEE ATTACHED NOTE THAT ALL DESIGN ELEMENTS AND LOAD PATH CALCULATIONS ARE BASED ON INFORMATION CONTAINED IN THE AMERICAN FOREST AND PAPER ASSOCIATION WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS. EGRES~ WIND ENERGY UGHT & VI~ITILATION WINDOW SCHEDULE c~.~ ~. SQ.~. iNUMBER LOCATION ROUGH OPENING OPENING OPENING UNIT RATING SHiJ~leR VALUE VALUE ROOM VENT 1. DIN. RM. 32-1/8' X4~7/8' 3~7/8' X 2A-1/4' 5.70 14.85 DP 50 NA .48 28 5.73 2. DIN. RM. ~4~ Xg-11' 2~1/8" X 7~1r 15.31 40.76 DP 40 SEE DETAJL .48 ~8 15.31 199 21.o4 t0.5 [ LIV. RM. g4)'Xg-11' 2~t/8'X78~/1~ 10.31 40.76 DP40 8EEDETAJL .48 ~8 15.31 4. UV. RM. 3"2-1/8' X4~7/8' 3~7/8' X 2~1/4" 5.70 14.85 DP 50 NA .48 ~8 5.73 199' 21.04 10~ 5. BEDRM1 3'2-1/8'X4~7/8" 3~7~'x24-1/4" 5.70 14.85 DPS0 NA .48 ~8 5.?3 6. BEDRM1 ~2-t/~'X4~7/8' 3~7/8'X24-1/4' 5.70 14.85 DPS0 NA .48 28 5.73 140' 11.48 8.1 7. BEDRM 2 32-1/8' X4~7/8' ~7~ X2~1~' 5.70 14~5 DP 50 NA 8. BEO~M2 3"2-1/~x4~7/~ 3~7~8'X2~1/4" 5.70 14.85 DPS0 NA .48 ~8 5.73 GENERAL NOTES FOR WOOl) PN~EI..~ FOR WIND-BORNE DEBR~ PROTECTION ALI. PANEI..~ WILL BE 1/2' CDX PLY~NOOD. TI-IEY WILL BE INSTAH = n WITH #8 WOOO ~.l~.~,~/S ~ t2' OC ~ THE 8CREW~ WILL PENETI~ATE 1-1f2' IdlN, INTO W,N.L ~-IEAll.flNG. THE F/~I'ENERS WILL BE INSTA~ ~ I;:n 1/2' FROM THE PANEL E3)GE (MIN.) THE SIZES REQUIRED FOR THE PANELS ARE 8HOWN BELOW. NOTE TI..iAT ON THE PANEt. S THAT ARE LONGER TI-IGAN 4'0" WE WILL INSTALL TWO 2 X 4 STir r~ERS ALONG 'n-lE LENGll-I DIMENaK)N OF EACH pANERL wm-I 2 - #8 SCREWS AT EACH END AND AT 12' OC ALONG 11-1E LENGTH OFTHE 2X4. STIFFENER~SHALL BE PLACED 1 FOOTOFFTHE CENTER OF THE PANEL CENTERLINE. [~='F~L #t WACKER ENCE DORMER EXPANSION ENVIRONMENT EAST INC. 3.3.10 EXIST. CHIMNEY (NO CHANGES) ', EXIST. DORMER TO BE ENLARGED SEE DWG. EXIST. 36' X 41" SINGLE PANE WOOO DH WINDOW. 8/8 EXIST. ASPHN.T SHINGLES  EXIST. DORMER TO BE E WOOD DH WINDOW. 8/8 EXIST. '-0" SLIDING GL S DOOR I WACKER RESIDENCE EXISTING SOUTH ELEVATION ENVIRONMENT EAST INC 1/4" = 1'-0' 3.1.10 EXIST. MASONRY STOOP EXIST. CEDAR SHINGLES EXIST. '-0" SLIDING GL ,S DOOR 4LARGED ~NE Al'nc EXIST. 36" PANE WOOO DH WINDOW. 8/8 EXISTING PARTIAL SECTION ENVIRONMENT EAST INC 1/4" = 1'-0" 3,1,10 EXIST. CHIMNEY (NO CHANGES) NEW DORMER ASHPALT SHINGLES TO MATCH EXIST. 1X 6 VERSATEX RAKE BOARD CEDAR SHINGLES TO MATCH EXIST. EXIST. ASPHALT SHINGLES 12 NEW DORMER I X 6 VERSATEX 2 - ANDERJ I WDH 3046 3~-1/8' X4 ta'RO EX]ST. } TO MATCH EXIST. N ¥ REPLA( XJST. WI NE~ ~11L 6'-0' X ( 'R.O. W~H 3048 3~-1/8' X 4'8-7/8' NEW FRAMED STOOP WACKER RESIDENCE PROPOSED SOUTH ELEVATION ENVIRONMENT EAST INC 1/4' = 1"0' 3.1.10 II EXIST. MASONRY STOOP II REPL~ F_XlST. WINEV YG60611L 6~-0' X l I' R,O. WDH3046 3~t/8'X 4~7ff NEW FRAMED STOOP I 3/4' X ;~1~" T&G PVC PORCH FLOORING -- EX]ST. FLOOR FRAMING NO CHANGES ADD NEW 1-3/4' X '11-1/2' MICRO LAM ~--~ REPLACE EXIST. 1Z-0' SLID. GL. DOOR W/NEW ANDERSON FWG60611L 6'4)' X ~-11" R.O. I I II EX]ST. FLOO~ele NOCH~GES.~C~: PROPOSED PARTIAI~cTION~ ENVIRONMENT EAST INC 1/4" = 1'~" 3.1.10 T NEW WDH 3048 REPLACE EXIST. 3'2-1/8" X W/NEW FWG60611L 4'8-7/8' 6'-0' X 6'-11' P.O. L, · 1-3/4' x 11-1J2' MICRO LAM HEADER 7'-11' ~' EXIST. DIN. RM. EXIST. ENTRY NO CHANGES NEW REPLACE EXIST. WDH 3046 W/NEW FWd11L 3'2-1/8" X 6-0" X 6'-11" R.O. 4"8-7/8" 1-3/4' x 11-1/2' MICRO 1.~ HEADER 2,_ 3 7'-11~ EXIST. LIV. RM. EXIST. KITCHEN NO CHANGES EXIST. MUDRM. NO CHANGES WACKER RESIDENCE FIRST FLOOR PLAN ENVIRONMENT EAST INC 1/4' = 1'-0' 3.1.10 F-.XJST. CLOSET NO CHANGES EXIST. TWO CAR GARAGE NO CHANGES I 0'-8 1/4' 2 - ANDERSON WDH 3046 3'2-1/8" X 4'8-7/8" Al'nC - 2-2X101 BEDROOM WACKER RESIDENCE SECOND FLOOR ENVIRONMENT EAST INC 1/4' = 1'-0" 3.4.10 0'-8 1/4' 2 - ANDER~3N WDH 3046 3'2-1/8' X 4'8-7/8' RO SURVEY OF PROPERTY ~ITUA T£ CUTC..HO GUE TOWN OF ~ SUFFOLK COEV~TY, NEW YORK S.C. TAX No. 1000-105-11-20 SCALE 1"--50' DECEMBER 2, 2009 FEBRUARY 1, 2010 ADDED TOPOGRAPHICAL SURVEY AREA 99,217 sq. ff. <TO TIE LINb) 2.278 aC. CERTIFIED TO' THOMAS S. WACKER ISABEL J. WACKER FIDELITY NATIONAL TITLE INSURANCE COMPANY S NOTES 1. ELEVATIONS ARE REFERENCED TO N.GV,D 1929 DATUId EXISTING ELEVATIONS ARE SHOWN THUS:~L:~ EXISTING CONTOUR LINES ARE SHOWN THUS / / / / / / / Y % Lic No 50467 / d~ f( go \ \ TO THIS SURVEY IS A VIOLATION Of SECTION 7209 OF THE NEW YORK STATE EDUCATION [AW COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S iNKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED '%. THE EXISTENCE OF RIGHTS OF WAY AND/OR EASEMENTS OF ~ECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED Nathan Taft Corw,n III Land Surveyor PHONE (6~1)727-2090 OFFICES LOCATED AT 1586 Moln Rood Fox (651)727-1727 29 309