HomeMy WebLinkAbout37301-Z ~,~T'yjF~,
f Town of Southold Annex 7/26/2013
+'yh ~ P.O. Box 1179
_ ~ 54375 Main Road
~t~~ Southold, New York 11971
''h,:.,~,YZ,.,a
CERTIFICATE OF OCCUPANCY
No: 36418 Date: 7/26/2013
THIS CERTIFIES that the building RESIDENTIAL ALTERATION
Location of Property: 120 Richmond Rd, Southold,
SCTM#: 473889 Sec/Block/Lot: 51.-6-IS
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
6/8/2012 pursuant to which Building Permit No. 37301 dated 6/18/2012
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
GAS HEATING SYSTEM AS APPLIED FOR
The certificate is issued to Koukounas, Konstantinos &Koukounas, Age
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
Aut r' S' natur~
TOWN OF SOUTHOLD
' ` BUILDING DEPARTMENT
~ TOWN CLERK'S OFFICE
• SOUTHOLD, NY
" ~ BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit 37301 Date: 611812012
Permission is hereby granted to:
Koukounas, Konstantinos &Koukounas, Ageliki
24-13 35th St
Astoria, NY 11103
To: install a Gas Heating System as applied for
At premises located at:
120 Richmond Rd, Southold
SCTM # 473889
Sec/Block/Lot # 51.-6-15
Pursuant to application dated 6/8/2012 and approved by the Building Inspector.
To expire on 12/18/2013.
Fees:
SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00
CO -ALTERATION TO DWELLING $50.00
Total: $250.00
-
Building Inspector
p/'/~~
Form 10.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Deparnnent with the following:
A. For new building or new use:
I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I % lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
I . Certificate of Occupancy -New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certitcate of Occupancy -Residential $15.00, Commercial $15.00
Date.
New Construction: Old or Pre-existing Building: (check one)
Location of Property: 1 ~Y V 111 ~~tYr~(l~ t~L. ~~-C~
House No. Street Hamlet
Owner or Owners of Property: '?1;~11'~ ~ (t~ j ~ V ~~~L M.'~>L' (1Q5
Suffolk County Tax Map No 1000, Section ~ ~ Block - ~ Lot
Subdivision Filed Map. Lot:
Permit No. ~ 3 d I Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval /
Request for: Temporary Certificate Final Certificate: I/ (check one)
Fee Submitted: $ -~r/~(,
A licant ignature
o~~,pF SOUTy
TOWN ~ SOUTNOLD BUILDING DE T.
765.1802
1 N
[ ]FOUNDATION 1ST [ ]ROUGH G.
[ ]FOUNDATION 2ND [ ] IN CATION
[ ]FRAMING /STRAPPING [ FINAL
[ ]FIREPLACE 8~ CHIMNEY [ ]FIRE SAFETY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION [ ]FIRE RESISTANT PENETRATION
[ ]ELECTRICAL (RO/UGH) [ ] ECTRICAL (FINAL)
REMARKS: ~ If/,1~~ ~.,LcJ-tJ f ,C~
~ ~
'7~
~ ~
DATE ~SPECTOR
J
ho~,~oF so~Tyo6
~ ~
TOWN OF SOUTNOLD BUILDING DEPT.
765-1802
1 NSPECTION
[ ]FOUNDATION 1ST [ ] RO N PLBG.
[ ]FOUNDATION 2ND [ ] 1 ULATION
[ ]FRAMING /STRAPPING [ FINAL
[ ]FIREPLACE 8~ CFIIMNEY [ ]FIRE SAFETY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION [ ]FIRE RESISTANT PENETRATION
( ]ELECTRICAL (ROUGH) [ ]ELECTRICAL (FINAL)
REMARKS: -
J
DATE ~ INSPECTOR
FIELD IlVSPECf~ON REPORT DATE COM4VIENTS
~ ~
FOUNDA'iTON (1ST} O
~ ~
C
a
FOUNDATION (ZND) ~
z
ti o
y
Roucx FxaNINC & y
PLUNKING
A
W
INSULATION PER N. Y. O
STATE ENERGY CODE C
- ~
r
FINAL
- ~q - ~ ADDITIONAL COMMENTS p
~Xq ~
~ o
z z
N A
9u
04
o
z
~e
TOWN OF SOUTHO~D BUILDING PERMIT APPLICATION CHEC6LIST
BUILDING DEPARTMENT , Do you have or need the following. before applying"
- ('T'OWN HALL board of Heahh
~ ~ ~ SOUTHOLD, NY 11971 4 sets olBuilding Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Survey
SoutholdTown.North Fork.net PERMI D ' eck
N ~ ptic form
Co ~ ~ ~ ~ Y.S. D.E.C.
ustees
/ oud Permit
Examined 1! .20~ JUN -8 P012 orm-Water Assessmem Porm
C ~~y~
Approved~((~20~ it to: 'Td~G
Disapproved a/c / BLDG. DEPT. _ _
T04JN Of SOUTHOLD ri one, _ (v/~/v'~4l
[zpiration r 20 I ~ / 1
' /Building Inspector
APPLICATION FOR BUILDING PERMIT
Date , 20_i_~
INSTRUCTIONS
a. This application MUST be completely filled in by h~pewrirer or in ink and submitted m [he Building Inspector with 4
sets ofplans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location o(lot and e(buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Llpon approval of this application, the Building Inspector will issue a Building Permit to the applicant Such a permit
shall he kept on the premises available Ibr inspection throughout the work.
e. No building shall be occupied or used in whole or in pan fur any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
C F.very building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within I8 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, [he extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Uepartntenl for the issuance o(a Building Permit pursuant to the
Building Zone Ordinance o([he Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction ofbuildings, additions. or alterations or (or removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building cod~ire sin de, a regulatioq , an to admit
au[IlpriZedjgsp¢e'ors ~p Qremrises and in building for necessar} inspections. I CS~oJ, °Alrf/J
I~~~ i~ UNLAWFUL (Signatureofa icantorna~ e,ifacorporalion)
~11T~-~i !T CERTIFIC~?TE ~(o~ n~Mt~
(Maili r a rV ~
tt ii ~ r~ ~I;,y, c l I
St3if IwhetMOw'2p(Slit~nd s~bwaer~ lessee, agent. architect, engineer, general contraR6Y'~~ 1®t1dr
ELECTRICAL
F-
` ~NOTIFY BUILDING DEPARTMENT AT
Name of owner of premises vxJ~e...~NV~.L C~F~rt8U~0' 8 TO 4I?~ enR THE
(As un the tax roll or latest d~LO`:VING INSPECTIONS: r
Ifapplicant is a corporation, signature of duly authorized officer 1. Fi~UNDATION -TWO REQUIRED
FUR POURED C011CRETE
(Name and title of corporate officer) 2 ROUGH -FRAMING PLUMBING,
Builders License No. STFEPPIWG. ELECTRICAL 6 CAUtKIMG
Plumbers License No. ~~ry~ ~ 3. WSUUFTIORL -
ElectriciansLicenseNo. 4. FINAL-CONSTRUCTIONBELECTRICAL
Other'I'mde's License No. MUST BE COMELETE FOR C.O.
lilt CONSTRUCTION 3FMWl MEET THE
L `L1oca-tion ofllla~nd on which pr`oposed~w`ork will a done: SRI/EU~IiII~R{EMEIyyT3~fKp~T~HpE~PrrO~DpE~3~4p1FpNEW
w\~~~V"~O KC- ,-~y ~6V ~ l M1I~YI~. rw/T rKJ~VrtiIrW,G rVr\
House Number Street Flaml ~ ERRORS
County Tax Map No. 1000 Section~_Block ~ Lot
Subdivision Filed Map No. Lot
n •
r9. State existing use and occupancy of premi ~s and intended use and occupancy of proposed construction:
• a. Gsisting use and occupancy O(h'u 1'
• b. Intended use and occupancy ~~P "~1Q~_(1Q ~~~'K.M'
3. Nature of work (check which applicable): New Building Addition~Alteration
Repair ~ Removal Demolition Other Work
(Description)
4. Estimated Cost ~ '2r gOO Fee
(To be paid on filing this application)
5. Ifdwelling, number of dwelling units 5+.. Number of dwelling units on each Door
If garage, number of cars
6. !f business, commercial or mixed occupancy. specify nature and extent of each h~pe of use. t~
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stones
9. Size of lot: Front Rear Depth,^, 11
10. Dale of Purchase Name of Former Owner ~ O \v
I I. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded'? YES NO Will excess fill be removed from premises? YF,S NO
14. Names of Owncr of premises Address Phone No.
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet ofa tidal +vetland or a freshwater wetland? *YES NO
* 1F YES, SOUTI TOLD TOWN TRUSTGES & D.G.C. PERMITS MAY l3E REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survcy, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at IU feet or below, must provide topographical data on survey.
1 R. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES. PROVIDE A COPY.
STATE OF NEW YORK)
II S.
`F-~l_.dX++:-T 1 • being duly sworn. deposes and says that (51he is the applicant
(Name of rvidual signing wntracQ above nam~ed/,~
(S)He is the ~ P~~ t°~ ~ • V `r ~T~ _
(Contractor, Agent, Corporate tcer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application:
that all statements wntained in this application are true to the best of his knowledge and belief; and that the work will be
performed in [he manner set forth in the application tiled therewith.
Sworn to before me th
day of 20~
CAROL R. McCabe
Notary Public ary U ic, State Of eW 0 Si nature o Ap w,or
No. Ot MC6130792
Qualified in New York County
Commission Expires July 25, 20 ~.1.
I IE#I,. ~A 4A I! 4a eei. s if~~ +#iY4" _ _
0
r'.::
_ .•cE ....xi:....
TM ~
~E~S2 Boiler
n_ ~ ~ iency, Natural Draft,
~ ~~zh~
EV}i~li`~t X' ~ t
(~fll~ y ?fi4 t~3i6 t P
u
fi t
~ r~ ~ , ~$'S% ~AF.U~E~~
,
o r
_m
Featwres Burnham iQ Control-System'" .
• True Plug 8c Play Contro#s Utilizing
Burnham iQ t?ption Gards; ~
- Outdoor Reset '
(with Domestic Hot WaterPriority) '
-Auxiliary High Limit s,
-.low Water tut-off '
Ifi
~a
- - Optional LCD Touch Screen Display
~
s' Improved Bailer Operation
i.
~,I
y
The ONLY 85% AFUE Atmospheric
Cast Iron Boiler Made in America
Qualifies for Energy Star Rebates
• Efficient Operation Saves
Homeowners Money!
• Innovative Design and Appearance
- _ Ideal Replacement for Millions of
Existing Boiler Installations
• 7 sizes, 70-280 MBH input
A Consumers Digest "Best Buy"
r .~:r~u~~
Burnham
Limited by
o Eifetime Boiler Compam~
,:r..., , Warranty
GREATER ENERGY SAVINGS
25
i
~ ~ _
r
~ ~ ~
~ ~ ~,,,n~q..:~ v1c
u
It's a whole New Game
;~~vavii~ w:= ,
.a°- nd the Burn 2 is in the Lead !
'~P.,.nP r , a~.yi ~
end,
' Meet the ES2...Unmatched Anywherei
U.S. Boiler Company is proud to introduce the new Burnham f52 boiler...
the first all new atmospheric, gas•fired; €~,t iron bait for hone heating ttrat
has been designed in decades. Boastint~aptoven, long-lasting, Americatt-
made cast iron heat engine, the ease & slm~kitY of atmospheric vetr~;
an exclusive control system that provitsfi~aAtres unrivaled bYatlyBet
in the market, an outstanding 85°k effjcBItGY STAi~ '~r~h
atmospheric gas boiler, and an attractit~. 6kr which'is or
superior to the design of the most sap ' ° , 't#tondensiflg boilers.
Who else can provide all of this to one~a " '
The answer is simple... NOBODY!
'4 Only U.S. Boiler Company hag wed great ~t .
~ savings with "green` E ratings; ble
Rw long-lasting cast troy iiew, m " : ~ ;
atmospheric gas `that is ~#-J~merica!
`The Ulti ' ~ ~epl Boiler
Why is tha mate rep.: id~i'? Because we make it si "
The ES~f.' , `designed to#~a ;ur''feplacement. Boiler conng,~tiory4,,.,.._
arec;#a`with ind
us~y , , 'near boiler piping configur s ,
Ge this means tt~t~,t ' r does not need to install a L
aping to conned t!I~* ' _ 'Rt Home's existing system.
' .rzpF ~I
R8'~etJt ds 8 Additionally rf yc~trf a a~ ~fte over two million Amer ~ F
equipped wrth aer _ ne d) gas boiler,
COt1SBtN@rS ,
~ have the basis fw~ q ~agrht n y ° "system th ~w it . '
~~gest take fulladvanta~~g ne ngcapabil'
r B@st BUy it's as simple as''. ~t neylinerthae ' s t ` ~ rk
of your chimney,t}I' {fNid 'i~irients w ~ '
The performance and. value of the ES2 ~
installing contr~ipr. t~, ~
has been recognized by Consumers LF ,
Digest Magazine. Retently, it achieved a
The ES2 is the f"tt3t ' `made, atmosphe
Consumers Digest "Best Buy" rating: boiler to allow tlteu~#€1 ~ himney. Previous *x
mm .m
"Tfre E51 delivers unmatched quality if a homeowner to a high efficien ,
and efficiency for an economy fioilar, replacement, they ~
~ov~e~
It is one of the least expensive models usually meant ~ ` ' ` aru! p~ ~ n
that we could find That includes wall, or the four ~ fiom fft~ ga§ ts~t~.
new Esz, you c~ get fsg?i tell ~'sti~ r
outdoor reset as an option for you " '
additional energy savings And you existing chimney ; , 'rteti the chamncy and liner meet the r~uirenrents
can add outabor reset among other specified by the inar~kifat,`tttter's r on insttutt;ons,:paing so yyl!
features, to this model via a simple Provide you with years of quiet, clean, efficient home }testing. In atldi#ion,
lu m module-a feature that's- the E52 has been designed with at low profile draft diverter. This means that
A g the vent connection to tltethimney has been lowered up to 19", making
typical of Bumham's penchant for easy vent installation quick and easy,
instatlation. "
26
I
c-~
America
The Best Boiler for Most Homes
The E52 was created with a single goal in mind - strike a balance
between high efficiency and real-world practicality. U.S. Boiler Company i4
has taken the proven, reliable and simple design of an atmospheric cast i ' ~ j ~ r';i~
iron boiler and!has attained what no other domestic manufacturer has on
this kind of boiler:.. an ENERGY STAR certification.
Designed to handle the kind of high water volume systems present in
mast homes, the rugged E52 cast iron heat exchanger can easily operate
with lower system return water temperatures than conventional cast
imn boners. Most cast iron boners require a minimum of at least 140°F
return water temperatures to prevent damage to the heat exchanger. The
€52 fia5 been designed to accept return water temperatures as low as
t tp°F without rnmpFcated piping ar additional controls. This means that
the boiler does nothaue to fire at a high rate to maintain comfortable -
temperatures in the home, which translates in HIGH EFFICIENCY and
ENERGYsavfngst _
AIsD the E52 is equipped, as standard, with the powerful, IQ Boiler -
~onttpl System which prouides operating controls and constantly d::' .
rs the E52 hour to help maximize operating efficiencies; and "
' her with an oprianaf Qutdoar Reset Control can provide unparalleled ' "
= ~ficiencies that can provide even greater energy savings. _ ' `
r~,. In additioh, the cast iron used in each E52 is manufattured using some _
of tfie most advanced faun~y.. ent and techniques available at
jt' ~umha F~ndry, LLC in ENSk7, flGO alarutpear^e of mind -
; ; ~ Look no #t tha E52. Each E52 is hacked by
i; TIMEWAf3Rrk' .,~tu}the ex€hangei'Additional
able bypur et~,SgiTOifer'El~tlWarranty
i esblanket ~ on~taltsandlafxarfor5ort0
i °~tom zrf u4staflahori.
'x~~
s
iiGY STAFF ~
STAR is a jointpr lrydteEfAmrdtfte U.S.
..itf Energy Therrgoaf essr~ridentifk~ale
of showing co fir' are the most energy
' . ENERGY57AR ha+~savedharrreowners ~ ~
~6~kat En utility,tosts. ~ ~ ~ ~ ~ 0.
3i
tnarrers y c ~I~ I°
'
thvhrg the E52 an Efd i4R certipeat~rn ~ ,
means That the purchase of an €52 may gttaflEy for ~
~S I
feskral and state tax rebatesthatrum-ENERGY ~ / _
S7AR froilers are not eligib~ for Additionafutflity n h, ~ _ _ _
rebates may also apply. Further details on these ~ ~ t'~"s3,`~r
l'
rebates are available online. Please visit r #4a`it ~ 1 ~ - _
www.dsireusa ora for a complete listing of available rebates. rr~; ~ ~ ,
~,!r
~
z ~ _ ,L - ~
s_v
~~@4r
ti@ _
'Draft Diverter
E ~ ¦ ¦ ¦ t reduces installed boiler height
up to 19", allowing a broader
The Inside Stol"~ ~ range of mstallations.lndudes
} 3~t a built-in, factory wired, i
- ~
v~ ~r~~ ~~tJif integrated spill switch.
P6Ity., a.~ta P
r
3 `'~S J }
elf,:: ;
Optional Di~lay Vent Connector Kit
Durable'. Saves time & simplifies
mntrasting installation, includes 5'
polyethy~ne hood flexible insulated double
I€ari tse fitted with wall vent connector
';;optional LCD touch and adapters for easy
'screen display connection to the
- chimney system
Convenient r
12Htction Boz
Withplenty of room for 120V
connections '.'~Ta
~~i"'
~;r
Supply & Return Tappings ~ " _
Match locations for industry- mw
®i(: Concealed
standard installations. Makes _ - Controls
replacing and older boiler easy! _ All boiler controls
~
~ ;;r are located inside
Ja' m the boiler jacket for
Attractive, Modern, ; safety and a clean
Insulated, Powder Coated i appearance
?E
Steel Jacket ~
Tough powder coated ~ POWDER Trapezoidal Legs
steel acket deli ned conreo with Nylon Glides
1 9 rouox°
for durability and great ~~E;l Allow for easy
appearance. Jacket is positioning of the
lined with thick insulation, and has an l,~ boiler, and protect
additional layer of insulation at the base i against potential
of the boiler. damage to flooring
a mw
]~4f
i ~0 _
#r Limited Lifetime Warranty
r The ES2 is protected with a limited lifetime warranty on the heat exchanger. Additional
" coverage is available by purchasing the U.S. Boiler Extended Warranty Plan which provides
blanket protection on parts and labor for 5 or 10 years from the date of installation.
Burnham AltianCe SLT`~tttdirect-fired Water Heaters'
Por an abundant supplynf domestic hatwater, fJesure to use an BurrrhamABiance SL indirect-tired water heater
with every bculer application. the Alliance SL water heaters are designed with an effective frydrastone lining that
offers superior corrosion resistance and outstandiru„t perfrzmance in a wide variety of water co~tior~s. Water
heaters are tvadable in five sizes. and come with a unique 1 Df2/t warranty -16 Yeats on the tank and Lail, 2
years tabor and 1 year on parts. An optional lifetime warranty is also available:
28
kf
IQ;Boiler tor?trol
Integrates aquastat, relay,
andlignition functions into a
single module. Mounted an
hinged panel for ease of access.
IQ Option Paml t
Accepts optional IQ Option f
Catdsforsimple "plug & play"
instgllatronof: W~ "s ,lt~' `1
-Outdoor Reset
- Low Water Cutoff Proven G3 Heat
-aquastat Y Exchanger
° a: Made of specially
ie'' ~ formulated BC25-HSi
high silicon grey iron,
this heat exchanger has
,
been precision formed to
create turbulent water
flow throughout all areas
of the heat exchanger,
eliminating hot and cold
.r
spots, and maximizing
'nr heat transfer.
~ ' F$ ,
I t 4'
Step Opening Gas Valve
This type of gas valve enables the Cast iron, proven for long life
boiler to light on low fire. Once a
flame is established, the valve gently
opens to full fire safely and smoothly.
This provides quiet ignition and
promotes long boiler life. i ,
3;4'Gg.
h G
G3 Base
F
Featuring heavy gauge steel construction, this base provides
unmatched stability and safety through its wrap-around design,
The design also provides a tighter seal with fewer joints. Thick
insulating plates direct the heat from the burner tubes upward into
a
_
the heat exchanger, helping to fully utilize every BTU possible from _
the combustion process. fie bestand ~~w~t'g;;,
longest lasting in -
y ~ k
Made.in~' i _
.
America.l,l,~~~
j_= a~ 1 m.
v ~3
s~„
t .s~
"mss
P' _
I
f
i
;Helps Improve Efficiency,
.`•.,.m Saving Energy and Money!
i~ w
ols, Like No Other...
~ . _„i,;~;.~
° G3 heat exchanger is the brawn of the ES2 Boiler, the IQ Boiler Control System is
.,..,ti..~ ~ the brains. The IQ Control System is designed specifically for the next generation of high
efficiency cast iron boilers. It simplifies boiler operating controls by combining all the
typical boiler safety controls, including ignition, into one central control module. LCD
readouts clearly communicate system status updates, and The end result is a control
system which is simple to read, simple to set up, and simple to diagnose.
The IQ Option Panel resides below the boiler control. The Option Panel permits the
addition of features to the boiler by way of Burnham's exclusive IQ Option Cards. These
~P' IpI V" ii~~~~~ option cards allow the "plug-n-play" installation of such features as Outdoor Reset,
i~ ~ ~ i ~ jl{ Low Water Cutoff, and an auxiliary Aquastat. Thanks to the unique design of the IQ
Option Panel, installation of these boiler control upgrades are extremely easy for the
qualified technician to perform.
' m.. IQ Outdoor Reset Card -for Increased Energy Savings
w-3w
A weather-sensitive control that adjusts the boiler temperature up or down based on
4~` c^-,
the outdoor air temperature. It's a simple concept. On cooler days, a home requires
t more heat to remain at a comfortable temperature inside. On these days, the boiler
r:.; m temperature is automatically adjusted upward. By contrast, on warmer days, a home
- requires less heat to maintain comfort, so the boiler temperature is adjusted down.
- Adjusting the boiler temperature has several advantages. Often it allows the boiler
to operate at a lower temperatures ,which enhances efficiency and can deliver
savings of 15-20°/a. It maximizes the comfort of the heating system by allowing the
boiler to run for longer cycles at a steady temperature, minimizing wasteful on/off
cycling. Adding the benefits of outdoor reset to the ES2 boiler is as simple as plugging
~°4:" the Option Card into the IQ Option Panel and connecting a 2-wire sensor. Additionally,
' ~ the IQ Outdoor Reset 0 tion Card contains man
p y powerful features normally found only
on large stand-alone control packages, such as:
• Selectable Domestic Hot Water Priority
Selectable & Adjustable Domestic Priority Protection
Adjustable Domestic Setpoint
• Selectable and Adjustable Temperature Boost
Y All settings on the IQ Outdoor Reset Option Card can be customized for ideal
performance in any heating system.
Heating System Efficiency in Relationship to
System Retum Water Temperature
2~ is
This is the ONLY boiler that T
takes real advantage of r 'S -
outdoor reset control. s = t~l
Because of the ES2's exceptional G3 heat a I
exchanger, theESl6oilercansafelyhandle W ~ repswmatonm.,.r.aae.uaaaw
-(aYMIPAfklryOraMeol lW Fb prevent
return water temperatures as lowas 110°F, sraeaa•.mm aw neei e,pw"x,
which significantly increases the system a '~''"inYhai°"0`""""""°"`r-
efficiency ofmost heating systems. Even
Aigher system efficiencies can be achieved by sy~m ~C1CnCy
adding the IQ Outdoor Reset Card to the IQ o -
Bailer Control System in an ES2, resulting in J ;I ~
more fuel savings and improved comfort. r
100°F 110°F 130°F 110°F 1e0°F 150°F 160°F 1]0°F 160°F
Heating SyAem fte[um Water Temperature
30
IQ Low Water Cut-Off (LWCO) Burnham lQ Option
Option Card Lard; LowWater
Cutoff with
• A safety device designed to disable the boiler if it senses that Manual Reset . a
,t''
the water level has dropped below safe operating limits. In some
areas this device is required by code to be on every new boiler ~ -
installation. Available in auto and manual reset versions, the IQ ;
LWCO Option Card plugs easily into the IQ Option Panel and feature ~ r_ '
a one-wire connection to the 3l4" sensor probe which is mounted
in the near boiler system piping. These cards feature built-in
diagnostics, adjustable setpoint & differential, and manual reset
versions are compatible with CSD-1 in the U.S. and Canada. Bumham IQ option card,
LowWater Cutoff with
- Automatic Reset
IQ Aquastat Option Card
An additional temperature sensing device that will disable the boiler
if it exceeds the built-in temperature limit. Required by local code in Burnham IQ option
some areas, the Aquastat Option Card plugs easily into the IQ Option card,Aquasrarwirh -
Panel and connects to the temperature sensor with a single plug-in Manual Reser
connection. IQ Aquastat cards feature built-in diagnostics, adjustable
setpoint & differential, and manual reset versions are compliant with ! `;p
CSD-1 in the U.S. and Canada.
_r
IQ Option Card List
Part Number Description
102723-01 IQ Outdoor Reset Option Card
102771-01 IQ LWCO Option Card -Auto Reset
102714-01 IQ LWCO Option Card -Manual Reset Burnham IQ Option
102717-01 IQ Hi Limit (Aquastat) Option Card -Auto Reset ~ card;Aquastai with
Automatic Reset
102720-01 IQ HI Limit (Aquastat) Option Card -Manual Reset
LCD Touch Screen Display
The IQ Touch Screen Display Kit offers the option of adding astate-of ~ ~
the-art 3.5" multi-color LCD touch screen display to the E52 boiler. The
display mounts in a special knock-out in the plastic hood above the front
door of the ES2 boiler and communicates with the IQ Boiler Control and
IQ Option Cards. All boiler settings, status and errors are displayed in
full text on the bright backlit display. The display features easy-to-follow
full-text explanations of all control settings, as well as help screens with
comprehensive diagnostics and troubleshooting information. In the event
of a boiler error or lock-out, the touch screen display turns red and flashes.
The display connects to the IQ control through a simple plug-in connection. ~ `x n,,,r;
The IQ Boiler Control System ~ c
,~l
a~«
Available EXCLUSIVELY from ~ a ~ w--_-- -
,
Boiler ~ ~-k
$A y`
i~`:
~:i.
~t~ /~~'~~~J 1.~
Ratings `ICIV~ tJ l~'R Mama
DOE 1=8RR Water
Male1 Input. Heating Capacity Ratings Eledricai
Number' (MBN) (MBH}' (MBH) AfUE°k Requirements**
ES23 70 59 51 85.0 <2 Amps
ES24 105 88 77 85.0 <2 Amps
ES25 140 118 102 85.0 <2 Amps
ES26 175 147 128 85.0 <2 Amps
ES27 210 176 153 85.0 <2 Amps
E528 245 206 179 85.0 <2 Amps
E529 280 235 205 85.0 c2 Amps
' Add suffix "N'" for na[wal gas, or suffix "C' for LP gas models
"Requirementior controls only, add (or amp draw of circulators.
All modek certifed for use from sea level to 10,000 (eet In elevation. Outputs are reduced by 2% per 1,000 feet In elevations from 5,000 to 10,000 (eet.
All ES2s are shipped with 30 psi relief valves, MAWP is 50 psi.
Specifications
Dimensions (inches) ConnettiarK (inches) Water Approx.
Mods CraS Retief Colftent ; Shipping Wt.
Number i N~idtlt Heist ;Depth Vent Supply Retum Valve Vahre (gal.) (Ibs-}
ES23 12-3/4" 41" 33" 4" 1-1 /4" 1-1/4" 1/2" 3/4" 2 250
ES24 15-1 /2" 41" 33" 5" 1-1 /4" 1-1/4" 1/2" 3/4" 3 300
ES25 18-1/2" 41" 33" 6" 1-1 /4" 1-1 /4" 1/2" 3/4" 4 350
ES26 21-1/2" 41" 33" 6" 1-1 /4" 1-1 /4" 1/2" 3/4" 5 410
ES27 24-3/4" 41" 33" 7" 1-1 /4" 1-1/4" 3/4" 3/4" 6 460
ES28 24-3/4" 41" 33" 7" 1-1 /4" 1-1/4" 3/4" 3/4" 7 510
ES29 30-3/4" 41" 33" 8" 1-1 /4" 1-1/4" 3/4" 3/4" 8 560
6" MIN' 12"
MAX
23"**
40~~FLUE
0
34"ELECTRICAL o VENTILATION AIR
gq' ~ INLET OPENINGS"'
27° PPLV
0
6" °
41" 18" A
15"R RN
12"
MAX
FLOOR FLOOR
LINE ~ ~ ~ 0 LINE ~ 4„~
4„ „W„ r1„
NOTES: D° 13" 24" 29"31" 43"
Caution: chimney, liner, and vent connector must meet requirements
specified by manufacturer i installation instructions w~.g~~~~~p
' Minimal radial distance around vent pipe and breeching miter CUm~ny
" Add height required to maintain 6" deaance from all breeching components
Area of each opening 1 zq. inch for ea[h 1,000 BTUH input-with minimum
of 100 sq. Inches. Height of opening should be half the width. m 2011 U.B. Boiler Company, Inc.- Lancaster, PA
The Best Buy Seal is a registered o-ademark of Consumers Digest Communications LLC and is used under license Phone: 1-888-432-8887 • www.usboileebumham.[om
32
I
i'
' RenF=w.
i
SUFFOLK COUNTY DEPARTMENT
OF CONSUMER AFFAIRS
MASTER
PLUMBER
N~MF
ROBERT DEMONTE
This des that the a10NEf~
DEMONTE PLUMBING a NEATING CORP
bearer is duly
licensed by the ow....
County of Suffolk 10/31/2007
Ctillord Coleman 43660-MP
a„~„ I evnuimx o"fr 10!01/2013