Loading...
HomeMy WebLinkAbout35024-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 6/21/2012 No: 35758 Date: 6/21/2012 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 2950 ROCKY POINT RD EAST MARION, SCTM #: 473889 Sec/Block/Lot: 31.-2-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore 10/31/2008 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: filed in this officed dated 35024 dated 9/24/2009 one story addition/alteration to an existing one family dwelling as applied for per ZBA #6287, dated 7/21/09. The certificate is issued to MICHAEL CONWAY (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 35024 9/30/11 7~~atur% FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35024 Z Date SEPTEMBER 24, 2009 Permission is hereby granted to: MICHAEL CONWAY 392 3RD ST. UNIT 8 BROOKLYN,NY 11215 for : ONE STORY ADDITION/ALTERATIONS TO SFD PER APPROVED PLANS AND ZBA #6287 AS APPLED FOR. at premises located at 2950 County Tax Map No. 473889 Section 031 pursuant to application dated OCTOBER Building Inspector to expire on MARCH ROCKY POINT RD EAST MARION Block 0002 Lot No. 001 31, 2008 and approved by the 24, 2011. Fee $ 200.00 Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildiugs, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of'electrical installation fi'om Board of Fire Uuderwriters. 4. Sworn statement frown plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, iudustrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. Bo For existil:g bui!dings (prior to April 9, 1957) non-conforming uses, or baildings and "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and uuusual natural or topographic features. 2. A properly completed applicatiou and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Bni[ding Inspector shall state the reasons therefor in writing to the applicant C. Fees I. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50 00, Swimming pool $50 00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00 2. Certificate ofOccupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy- $25 4. Updated Ce~"tificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Coulmercial $15.00 New Construction: Location of Property: Old or Pre-existing Building: 2 ,e, cy_x I ?o1 4 ,def. House No. Street Owner or Owners of Prope,ly: ]¢[/'~;["]~I~'[ Suffolk County Tax Map No 1000, Section Su6division Permit No. -~ -~(~2q Date of Permit. Health Dept. Approval: Date. o~"/~'k.~ I"~,~ ~..~r/-'~...~ W'/ (check one) B lock Filed Map. Applican!: Underwriters Approval: Hamlet Lot: Planning Board Approval: Request for: Temporary Certificate Fee Subnldted $ ~"-~ ""- Final Certificate: (check one) TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [p~FO_UNDATION 1ST [ ] ROUGH PLBG. [~'F~UNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] FtqEREmTANTC0mmUCn0. [ ] FINAL ] FIRE $A~-,-; ~ INSPECTION ] RRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] ROUGH PLBG. ~INDATION 2ND FRAMING / STRAPPING FIREPLACE & CHIMNEY [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT COHmUCTIOfl [ REMARKS: ~.~<~.~.~ ~ / ~ ] FIRE RESISTANT PENETRATION DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 ] FOUNDATION 1ST ] FOUNDATION 2ND ] FRAMING / STRAPPING ] FIREPLACE & CHIMNEY ] F~RESmSTA.TCOm'mUCTm~ INSPECTION [ ~ PLBG. [ ,/] INSULATION [ ] FINAL [ ] FIRE SA,-,- m ( INSPECTION [ ] m~,WTm'ENLm~ATI0N REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION  [ ] FIRE RESISTANT PENETRATION [ ] ELE(; ;.ICAL (FINAL) DATE INSPECTOR~'~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INS~JL'~ION FRAMING/STRAPPING [~'~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION[ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: ~~-~ C~'~ INSPECTOR lq~/;/.~ INSpEC'~ON REPORT DA~ FO~A~ON (1ST) FO~A~ON (2~) PL~G STA~ E~GY CODE , , ~D~ION~ COUNTS TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N~Y 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Disapproved a/c Expiration PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Storm-Water Assessment Form - Mail to: Phone: Building Inspector APPLICATION FOR BUILDING PERMIT Date /o- qt9 ,2001;' INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced belbre issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available Ibr inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~re o%~ name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner ofpremises ~ td~"~ d Co* WO7 (As on the t~ roll or latest deed) If applicant is a co¢oration, si~ature of duly authorized officer (Name and title of corporate officer) Builders LicenseNo. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Hamlet ~ .~ { SubdivisionC°UntyTax MapNo. (000 Section t'/'~3 <~q ~B~_L~' - !__ t 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building_ Repair Removal Demolition Addition Other Work 4. Estimated Cost 5. if dwelling, number of dwelling units If garage, number of cars -Fee' C.,-.~Alteration (Description) j~:. (To be paid on filing this application) lqu~Ber of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Dimensions of same structure with alterations or additions: Front Depth Go"" Height /'~ ' 10. Date of Purchase Dimensions of entire new construction: Front Height / ~ Number of Stories Size of lot: Front ~'o, 13 Rear /oo Number of Stories Rear ,2_'-/ .Depth ~ lO / ~r/ .~lO. Depth Depth Rear S-' Name of Former Owner If]teK 11. Zone or use district in which premises are situated (L-~ ¢52 12. Does proposed construction violate any zoning law, ordinance or regulation? YES / NO__ 13. Will lot be re-graded? YES NO /Will excess fill be removed ~om premises? YES NO 14. Names of Owner of premises ~lcgOr[ ~7 Address ~LvW W..V . Phone No. Name of Architect Address ' / / Phone No N~e of Contractor~ Address~,~x~gq ~,~ Phone No. 15 a. Is this prope~y within 100 feet of a tidal wetl~d or a freshwater wetland? YES NO * IF YES, SOUTHOLD TO~ TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this prope~y within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrict!~ns with respect to this property? * YES NO t./ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) ~, c/~ d,t4 /~g."*/ being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, /~)He is the O0"*dTt~t~,{ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this ~Z~\~'f dayof C~ Notary Pu% FORM NO. 3 NOTICE OF DISAPPROVAL TO: Richard Feehan For Michael Conway P.O. Box 364 Orient, NY 11957 Please take notice that your application dated October 31, 2008 DATE: November 6, 2008 For permit to construct an addition and alteration to an existing single family dwelling at Location of property: 2950 Rocky Point Rd., East Marion County Tax Map No. 1000 - Section 31 Block 2_ Lot 1_ Is retumed herewith and disapproved on the following grounds: The proposed addition and alteration to this existing single family dwelling, on a non- conforming 21,000 +/- square foot lot in the Residential R-40 District is not permitted pursuant to Article XXII1 Section 280-124, non-conforming lots, measuring 20,000 to 39,999 square feet in total size, require a minimum side yard setback of 15 feet, proposed construction is shown at 10 +/- feet. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file, Z.B.A. Office Location: Town Annex/First Floor, Capital One Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 Mailing Address: 53095 Main Road P.O. Box 1179 Southold, NY 11971-0959 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 Fax (631) 765-5 FINDINGS, DELIBERATIONS, AND DETERMINI MEETING HELD JULY 21, 2009 ZBA FILE # 6287 - MICHAEL CONWAY, Applicant PROPERTY LOCATION: 2950 Rocky Point Road, East Marion TOWN O~ SOUTHOLD CTM 31-2-1 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. PROPERTY FACTS/DESCRIPTION: The subject property is a non-conforming 21,000+/- square foot lot measuring 100 feet along Rocky Point Road and 210 feet deep. It is improved with a single-story, one family dwelling as shown on the survey prepared by Otto W. Van Tuyl and Son dated November 26, 1963. BASIS OF APPLICATION: Request for a Vadance under Section 280-124, based on the Building Inspector's November 6, 2008 Notice of Disapproval conceming a proposed addition and alterations to the existing single-family dwelling on a nonconforming 21,000+/- square foot lot, stating that the new construction will be less than the code-required minimum side yard of 15 feet. LWRP: This application is not subject to review under Chapter 268 because the variance relief requested does not involve features that relate to a regulated natural feature or a bulkhead or other shoreline. RELIEF REQUESTED: The applicant proposes an addition on the rear of their single-family dwelling measuring 5 ft. by 24 ft. to expand the size of the living room. The addition will maintain the pre-existing non-conforming side yard setback at 10 feet, where the code requires 15 feet. REASONS FOR BOARD 'ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the followinQ.findings: 1. Town Law .~267-b(3)!b)(3)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The proposed addition is only 5 ft. deep and 18 fl. high and will be in the very large rear yard of thi~ property, so it will not be visible from the read. The rear yard and side yards are screened from neighbors by mature trees:and vegetation. 2. Town Law .~267-b(3)(b)(2). The benefit sought cannot be achieved by some method, feasible for the applicant to pursue, other than an area vadance because the house was originally built many years ago with a 10 ft. side yard (nonconforming). Stepping back the proposed addition by another 5 feet would create a much less functional and attractive amhitectural solution to the applicant's needs for an expanded living room space. Page 2 - July 21, 2009 ZBA FILE # 6287 - MICHAEL CONWAY CTM 31-2-1 3. Town Law ~267-b{31(b)(3). The vadance granted herein/s not substantial in so far as the proposed addilion will maintain an exisling 10 fl. side yard and the fact that the house is located vary dose to the sou~erly pmde~ line, leaving a 16 +/- foot on the side yard on the norlh on a vary narrow lot. 4. Town Law ~267-b(3)(b){S). The difficulty has not been self-a'eated but is the result of a )re-exislJng non-conforming side yard. 5. Town Law ~267~31¢b~4). No evidence has been subrnit~ed to suggest that a variance in this residential community will have an adverse impact on ~e physical or envimnmantal condilJons in the neighborhood. The subject pmpsrty is fiat, and the proposed addition is to be built on slab without land disturbance. 6. Town Law ~267-b. Grant of the requested relief is the minimum action necessa~ and adequate to enable the applloant to enjoy the benefit of an expanded living mom space, while preserving and protec~ng the character of the neighborhood and the health, safer7 and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying ~ balandng test under New York Town Law 267-B, motion was offered by Member Weisman, seconded by Member Schneider, and duly canied, to GRANT the variance as applied for and shown on the architectural plans dated October 2008 (Project No. 08051) numbered sheets 1-5 prepared by Edward J. Cebul, Design Den, subject to the following Condition: The extension sh~ll be oufitlsd with ~lUt~rs and leaders as per code Any devialbn from the variance given such as extensions, or demolrdons which am not shown on the applicant's diagrams or survey site maps, are not authorized under this applicalfo~ when involving nonconformities under the zoning code. This action does not autY~)dze or condone any current or future use, setback or other feature of the subject pmpsn'y that may violate the Zoning Code, other than such usus, satbasks and other features as am exprassly addrassud in this action. The Board reserves the right to subslitute a simila~ design that is de minimla in nature for an ahemlion that does not increase Vote of the Board: Ayes: Members Goehringer (Chairman), Simg~, Waisman, ~/Sc~lder~)~lay:~/i~wnber Resolution was duly adopted (4-0). / _~ ~._.//~/ /GERA~R~P. OOEHRING~-~, CHAIN ~)pi~ov~ forFiling 7-27-09 Simon. This Town of Sou __ thold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FOS~I PROPERTY LOCATION: S,C,T,M. #: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF ~ STORM-WATER, GRADING, DRAINAGE AND EROSIOH CONTROL PLi~I CERTIFIED BY A DESIGN PROFESSI('~NAL IN THE STAT~. Item Number: 1 2 3 4 (NOTE: A Check Mark (~') for each Question is Required for a Complete Application) Will this Project Retain All Storm-Waler Run-Off Generaled by a Two (2"/ inch Rainfall on Site? (This iLem will include all run-off created by site clearing and/or conslruction activities as well as all Sile Improvements and the permanent creation of impervious surfaces) Does tile Sde Plan and/or Su~,ey Show All Proposed Drainage Structures Indicating Size & Location? This Item shall include all Proposed Grade Changes and Stopes Controlling Surface Wated:low! Will this Project Require any Land Fil!ing, Grading or Excavation where there is a change to lhe Natural Existing Grade Involving more than 200 Cubic Yards of Matedal within any Parcel? Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five fhousand (5,000) Square Feei or Ground Sudr~lce? (This ilem will NOT include tile Installation of Driveway Aprons.) Yes hlc Y e~s N~ STATt,; OF NE\~' YORK COl JNTS' (); ................. Owue~ and/o~ rep[eseuta~xe of O~e OX~lleI O( 0 le s, a d ~s duly au~ouzed to perform or have performed O~e smd ~ork and make m~ct file this applica~on; O~at all s~temems conUincd iu ~is applica~ou am m~e to O~e best of his ~owledge mid beliefi O~a~ Om work will be perfi~rmed m fl~e m~mer set forO~ m Ore applica~on filed he~ewiO~ Sworn ~o before me FORM - 06/07 Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD Telephone (631 ) 765-1802 Fax (631 ) 765-9502 ro.qer.richert~,,town.southold.ny.us CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Conway Address: 2950 Rocky Point Rd City: East Madon St: NY Zip: 11939 ~uilding permit #: 35024 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Hubbard Electric License No: 4709-me SITE DETAILS Office Use Only Commefical Outdoor 1st Floor New Renovation 2nd Floor Addition Survey Attic Service 3 ph Hot Water Main Panel NC Condenser Sub Panel NC Blower Transformer Appliances Disconnect Switches Other Equipment: 1 -paddle fan INVENTORY Duplec Recpt GFCI Recpt Single Recpt Range Recpt Dryer Recpt Twist Lcck ~  Service Only ~ Pool Hot Tub Garage Ceiling Fixtures ~ HiD Fixtures Wall Fixtures ~'1 Smoke Detectors Recessed Fixtures ~ CO Detectors Fluorescent Fixture ~ Pumps Emergency Fixtures~__.~ Time Clocks Exit Fixtures [~..j TVSS Notes: inspector Signature: Date: Sept 30 2011 81-Cert Electrical Compliance Form Town Hall Annex $4375 Ma~n Road P.O. Box 1179 Southold, NY 11971-09,59 Telephone (631) 765-180') ro~ter richert~,~w(~.~o7 u~o~.n¥.us BUILDING DEPARTMF. aNT TOWN OF $OUTHOLr~ APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Company Name: Name: License No.: Address: Phone No.: Date: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: ~ / *Phone No.: Permit No.: Tax Map District: 1000 Section: ~/~ 3, ~'~ Block: 3 / Lot: ~.-I *BRIEF DESCRIPTION OF WORK (Please Print Clearly) ~., (Please Circle All That Apply) *Is job ready for inspection: *Do you need a Temp Certificate: Temp Information (If needed} *Service Size: 1 Phase 3Phase 100 *New Service: Re-connect Underground Additional Information: Rough In Final 150 200 300 350 400 Other Number of Meters Change of Service Overhead PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD October 7, 2011 Michael Conway 392 3~d St. Unit 8 Brooklyn, NY 11215 Re: 2950 Rocky Point Rd, East Marion TO WHOM IT MAY CONCERN: The Following Item(s) Are Needed To Complete Your Certificate of Occupancy: ~" Applic~/for Certificate of Occupancy. (Enclosed)  E lectrica!~erwriters Certificate. / A fee of $~. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing sfter 4/tl84) __ Trustees Certificate of Compliance. (Town Trustees #765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. - Bob Fisher Final Landmark Preservation approval. BUILDING PERMIT: 35024- Addition/alterations Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (63 I) 765-9502 April 23, 2012 BUILDING DEPARTMENT TOWN O1* SOUTI-IOLD Michael Conway 392 3rd St Unit 8 Brooklyn, NY 11215 RE: 2950 Rocky Point Rd, East Marion TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: /~ Application for Certificate of Occupancy. (Enclosed) / Electrical Underwriters Certificate. (contact your electrician) / A fee of $50.00. __ Final Health Department Approval. __ Plumbers Solder Certificate. (All permits involving plumbing after 4/1184) __ Trustees Certificate of Compliance. (Town Trustees#765-1892) __ Final Planning Board Approval. (Planning # 765-1938) Final Fire Inspection from Fire Marshall. __ Final Landmark Preservation approval. BUILDING PERMIT: 35024- Addition/Alterations June 12,2012 Buildings Department Town Hall Annex 54375 Main Road PO Box ].179 Southold, NY 1:197:1-0959 To Whom It May Concern: Enclosed please find my application for certificate of occupancy and a check for $50 covering your fee. My husband, Michael Conway, died earlier this year (copy of Death Certificate enclosed), and the house has passed to me through his estate. Unfortunately, I don't know who the electrician is who did the work for Richard Feehan, the general contractor from Allied Builders who buil~'this project. I know Richard submitted the building survey to you. When I asked Richard earlier this year about the electrical inspection, he told me that the electrician had filed his paperwork with you. If you cannot locate this paperwork, please be in touch with Richard Feehan directly at (631) 323-2406 or (631) 553-2386. I can be reached at (9:17) 499-6320 if you need to discuss this further. Many thanks for your help with this. Sincerely, 392 Third Street, Apt 8 Brooklyn, NY 1:1215 Cc: Richard Feehan Box 364 Orient, NY 11957 ~ TRANS(~RIPT / DEATH 'DATE FILED THE CiTY Of NEW YORK- DEPARTMENT ALTH AND MENTAL HYGIENE ~ertificate N6, 156-12'000204 CERTIF CATE OF DEATH ': w¥O C,TY l AND M~NTAL HYGIENE LEGAL NAME MICHAEL JANUARY 04, 2012 01:53 PM 1. DECEDENT'S , ~ ~ / (First, Middle, Last) 2c, T~pe of Place 4 [~ Nursing Home~-ong CONWAY / -~d. Any Hospice care 2e. Name of hospital or other tacil~ (i~ not lasility, street address) n last 30 days 1 [~Yes 2 · No pita! !, 6. CertiSer: I certify that death occurred at the time, date and place indicated and that to the best of my knowledge b'auma§~ injury or poisoning DID NOT play any part in causing death, and that death did not oc~r in any unusual manner and was due entirely to NATURAL CAUSES. See Instructions on reverse of cedltlcate. Nameof Physisian Annie Ressalam MD ! , (Type or Print) ; ~ress 506 Sixth Street, Br06klyn, New york 11215 7b- County 8. Date of Blrth (Month) (Day) (years) Signature , Signature Elsctronicagy Authenticated License No.~43701~ Date JAN-01-2012 :8 11215 Under 1 Year Under 1 D~y 10. Social Security Ne. September 25 1951 60 5[3 Associate,¢egree (p.g,, AA,~) ,,; 6 ~ Bache ~'s degt~ (~.g: BA';"~, Edward Conway Simmen 8~Unknown Robin Simme~ ~ Maiden Nam~ Prior to first marriage) (First. Mlddte, Last} Bernadette Young: -- ' 20c, Address IStrdet and Number ADt. No. Cdy & State 392 3 Street B, [ ZiP Code 21 d. Date of Disposition 01 06 2012 Brooklyn New York Blair-M~?7~rella Funera~ Home 723 Coney Island Avenue, Brooklyq, New York 11218 VR 15 or alteration ol this trahscrlpt is prohibited by §3 19(b) of the New York City Health Code if the DATE ISSUED January 05; 2012 Order No. 20120100934 Steven P. S w rtz, ~-h~D. Cit'~egistrar X0001159~ AC. pRD. CERTIFICATE OF LIABILITY INSURANCE GEORGE FORMES 1115 MAIN ROAD SUITEA2 PO BOX 2336 AQUEI~OGUE, N.Y, t1931 RICHARD FEEHAN PO BOX 364 ORIENT, NY 11957 09/29/2009 631-722.4100 THIS CERTIFICATE 18 ISf~UED A~ A MATTER OF IN~-O~,ieATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AMEND, E~END OR ALTER THE COVE~GE AFFORDED BY THE POLmlES BELOW, / NSURERS AFFORDING COVERAeE COVERAGES 'I'H~ POLICIES OF INSURANCE I. ISTEO EI~LOW HAV~ BEEN ISSUED TO T~E INSURED NAMED ABOVE FOR THE POLICY PERIOD rNDICATED, NO?WITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER OOCUMENT WITH RESP;CT TO WHICH THIS CERTIFICATE MAY ~E ~$$UED OR MAY pERTAIN. THE INSURANCE AFFORDED ~Y THE POLtCIES OE$CRIBEO HEREIN IS SUBJECT TO ALL TH~ TERMS. EXCLUSIONS AND CONDITION~ OF ~UCH POUC E~ AGGREGAT; LIMITS SHOWN MAY HAVE BEEN REDUCED ~Y ~AID CLAIMS. ..................... ANY AUTO 07/07/09 RETENTION OTHER 3101W6638 I, 07/07/09 CARPENTRY i 07/07/10 .__! ooo _ooo_ ..... Z,9_oo,~o_o_o_. ___ 2 o_o_.o_o_9o__ 100,000 ~o~o oo~o 500,0OO CONWAY PERMIT APPLICATION CERTIFICATE HOLDER TOWN OF SOUTHOLD TOWN HALL 5309§ ROUTE 25 PO BOX 1179 SOUTHOLD, NY 11971 ACORD 25 (200~108) CANCELLATION ~"-- 'ACORDCORPORATION t988 REScheck Software Version 4.2.0 Compliance Certificate Project Title: CONWAY PROJECT Energy Code: 2007 New York Energy Conservation Construction Code Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type Non-Electric Glazing Area Percentage: 29% Heating Degree Days: 5750 Construction Site: 2950 ROCKY POINT ROAD EAST MARION, NY 11957 Owner/Agent: CONWAY 2950 ROCKY POINT ROAD EAST MARION, NY 11957 Compliance: 0.7% Better Than Code Maximum UA: 140 Your UA: 139 Designer/Contractor: ALLIED BUILDERS MAIN ROAD ORIENT, NY 11957 631 553 2386 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Deiling (no attic) Wall 1: Wood Frame, 16"o c Window 1: Wood Frame:Double Pane with Low-E Door 1: Glass Floor 1: Slab-On-Grade:Unheated Insulation depth: 25' Boiler 1: Other (Except Gas-Fired Steam) 85 AFUE 250 380 0 0 8 220 19 0 0 0 11 512 13 0 3 0 26 69 0~310 21 79 0.320 25 64 7.5 48 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application The proposed systen~s have been designed to meet the 2007 New York Energy Conservation Construction Code requirements When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of hia/her knowledge, belief, and professional judgment, stroh plans or specifications are in compliance with this Code SEP Project Title CONWAY PROJECT Repo~t date: 10/17/08 Data filename: C:~Documents anc Settings\EDWARD CEBUL\My Documents~ACAD PROJECTS\RES CHECK ENERGY CALCS\CONWAY JOB rck Page 1 of 4 REScheck Software Version 4.2.0 Inspection Checklist Ceilings: _J Ceiling 1: F~at Ceiling or Scisso~ Trus~% R-38 0 cavity insuiahan ...J Ceiling 2 Cathedral Ceiling (no attic), R-19 0 cavity insulation Comments: Above-Grade Walls: Wal~ 1: Wood Flame, 16" o c, R-13 0 cavity ~- R-3 0 continuous insulation Windows; Window 1: Wood Frame:Double Pane with Low-E, U factor: 0310 For windows without ~abeled U-factors, desorib~ features: #Panes _ Frame Type _ Thern~a~Break? Yes No Door 1: Glass, U-factor: 0.320 Floors; ...J F~oor 1: Slab-On-Grade:Unheated, 25' insulation depth, R-75 r, ontinuous insulation Slab insulation extends down from the top of the slab to at least 2 5 ft OR down to at least the bo,om of the slab then horizontally for a total distance of 2.5 IL Exterior if~sulation has a rigid, opeque, weather-resistant p~otective covenng that (;overs the exposed (above-grade) insutation and extends at least 6 in below grade Heating and Cooling Equipment: Boiler 1: Other (Except Gas-Fired Steam) 85 AFUE or higher Make and Model Number: Air Leakage: Joints, penetrations, and all other such openings in the buildin9 envelope that are sources of air leakage are sealed Recessed lights are 1 ) Type lC rated, or 2) installed inside an appropriate air tight assembly with a 0.5" clearance from combustible materials If non4C rated, hxtures are i¢~stalled with a 3" clearance from insulation. Vapor Retarder: j Installed on the warm in-winter siee of all non-vented flamed ceilings, walls, and floors Materials Identification; _.1 Materials and equipment are installed in accordance with !he manufacturer's installation instructions ,...1 Materials and equipment are identified so that compliance can be determined ~, j Manufacturer manuals for all installed heating and cooling equipment and service water heatin _j Insulation R-values, glazing U-factors, and heating equipment efficiency are eleady marked on~l Insulation is ir~stalied acoording to manufacturer's instructions, in substantial contact with the s ~ that achieves the rated R-value without compressing the insulation Duct Insulation: ' _] Supp y duc s n uncood one I at ic-~ or ou side the building are instJlated to at least R-8 Project Title: CONWAY PROJECT Repolt date: 10/17/08 Data filename: C:kOocuments and Settings\EDWARD CEBUL\My Documents\ACAD PROJECTS\RES CHECK ENERGY CALCS\CONWAY JOB.rok Page 2 of 4 . Rerun%ducts in unconrgtioned attics or outside the building are insulated to at least Supply ducts in unconditioned spaces are insulated to at leagt R-8 Return ducts in unconditioned spaces (exo3. pt basements} are insulated to R-2 Insulation is not required on return ducts in basements Duct Construction: All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes Tapes and m~stios are rated UL 181A or LJL 181B Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. wg. (500 Pa) Temperature Controls: Electric Systems: Fireplaces: Fireplaces are instal{ed with tight fitting non-combustible fireplace doors State, the Residential Code of New York State or the New York City Building Code, as applicable Service Water Heating: is par~ of a circuJatir~g system Circulating hot water pipes are insulated Id the levers in Table 1 Circulating Hot Water Systems: Swimming Pools: Heating and Cooling Piping Insulation: HVAC piping conveyln9 fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2 Project Title: CONWAY PROJECT Report date: 10/17/08 Data fllename: C:\Docum~nts and Settings~EDWARD CESUL\My DocumentskACAD PROJECTS\RES CHECK ENERGY CALCS\CONWAY JOB rck Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circu.lating Mains and Runouts Iteated Water Lip to 1" Up to 1 25" 1 5" to 2 0" Over 2" Temperature f70 180 05 i~i 1 ~ 20 140-169 0.5 0.5 ~.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVA C Pipes Fluin Temp Piping System Types Range(OF) Heating Systems Low Prossure/Temperature 201 250 1 0 1 5 Low Temperature 120-200 0 5 I 0 Steam Condensate (for feed water) Any 1 0 1 0 Cooling Systems Chilled Water Refrigerant a~d 40 55 0 5 0 5 Bri[~e BeLow 40 1.0 1.0 Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" a~d Less 1 25" to 20" 2 5" to 4" 15 2 0 15 20 075 10 NOTES TO FIELD: (Building Department Use Only) Projec[ Title: CONWAY PROJECT Repor~ date: 10/17,'08 Data fi~onam¢, C:\Documents and Setdngs~EDWARD CEBUL\My Documents\ACAD PROJECTS\RES CHECK ENERGY CALCS\CGNWAY ,lOB rck Page 4 of 4 t RIGHT SIDE VIEW SCALE 1/8" = 1' REAR ELEVATION SCALE 1/8" = 1' LEFT SIDE VIEW SCALE 1/8" = 1' COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF BOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S. DEC PROPOSED FIRST FOR FLOOR THE EXTENSION CONWAY PROJECT ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. 2950 ROCKY POINT RD EAST MARION,NEW YORK 1 of 5 TITLE SHEET 2of5 3of5 4of5 5of5 INDEX FLOOR & FOUNDATION PLANS & DETAILS SECTION AND DETAILS CODE COMPLIANCE CODE COMPLIANCE PURSUANT TO CHAP IIr-I~/.Gu SF THE TNWN Gog~, NAILING & CONNECTIONS OCCUPANCY OR WITNI~I IT RF:RTII::IFt. AT~ OF OCCUPANCY FEE: C~OF). {hi BY V ~ 765-1802 8AM TO 4PM FOR THE 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3 INSULATION BE COMPLETE FOR CO. REQUIREMENTS OF THE CODES OF NEW DESIGN OR CONSTRUCTION ERRORS TOWN OF SOUTHHOLD USE RESIDENTIAL OCCUPANCY CLASS RES. HEIGHT OF BUILDING NOT TO EXCEED 2 1/2 TYPE OF CONSTRUCTION TYPE 5 JOB DESCRIPTION: FIRST FLOOR ADDITION STORIES PLAN PREPARED FOR RE~IEW 10/12/O8 REVISION DATE FRONT ELEVATION  TITLE SHEET LOCATION: 2950 ROCKY POINT RD. OWNER: MR. CONWA Y MA;~wARR°~°J'DESIGN °¢~'~uN['DEN NY ,,gS~ DRAWN BY: EJC SCALE: AS NOTED PROd No. 08051 JCHECKED BY: SP FILE: DATE: OCT. 2008 SHEET No. OF I NEW EXTENSION TO LIVING ROOM NEW EXTENSION TO LIVING ROOM LIVING ROOM · ~, !~ OeMO WALL LIVING ROOM *' x ~ ~ NEW WALL I EXISTING WALLS FOUNDATION PLAN SCALE 1/4" = 1' BEDROOM ~ CARB~ M~OXIDE DE~CTORS SHA~ BE mN ACCORDANCE ~m STA~ mPC REQUmREMENTS m ~NSL , ~o~. ~ V~N?ILA?ION AND LIGHT ~ SUS-~ASE BEDROOM SECTION "A"-"A" BATHROOM FRONT D SITTING ROOM OR ENTRANCE FOYER FLOOR PLAN SCALE 1/4" = 1' t~ FOUNDATION PLAN LOCATION: 2950 ROCKY POINT RD. OWNER: MR CONWA Y ALL/ED BUILDERS CUSTOM REMODELINO MAiN ROAD, ORIENT, NY 11957 EDWARD d. CEBUL SHEET No. DESIGN DEN ENGINEERS, PLANNERS, DESIGNERS / 6 HOWE ROAD, CORAM, NEW YORK 11727 PHONE & FAX (631) 698--4257 OF pR~P~O FOR ~'4~ m/~2/OS BY: EJC SCALE: AS NOTED PROd No. 08051 ~. REVISION DATE CHECKED BY: SP DATE: OCT. 2008 f II SUPPBRT SHUTTER SHUTTER DESIGN NOTES: I. SHUTTERS MEASUREMENTS TO BE ADJUSTED TO FIT INSIDE OF WINDOW FRAME. 2. PLYWOOD TO BE FASTENED TO THE ! "X4" WITH 1 ~" NON-RUSTING WOOD SCREWS INSTALLED FROM THE PLYWOOD SIDE EVERY 6" OC. 3. SHUTTERS TO BE STORED ON SITE FOR USE DURING STORMS. 4. HOME OWNER TO BE INSTRUCTED ON THE INSTALLATION. RIDGE TO PLANS) ~/2' cox NOTE- ROOF VENT ,.~.ALL DE 'RI.D~E, FILTER S~¢INGLE VENT' AS APPRO'~D EC4JAL INSTALL IN AC~DANCE ~7H MANU~)AC)URES ~DGE VENT DETAIL NTS FACE MOUNT JOIST HANGERS SCALE. N,TS. 2X 8EARING WALL - HEADER DETAIl TOP TEFRA lNG TAIL $1UDS OUTSIDE CORNER INSIDE CORNER SIMPSON 7 HURRICANE CONT, VENTED 2"x4"~16" O.C. SllJD WALL VYNAL SIDING OVER 3/8' RIDGE INSULATION OVER HOUSE OVER 1/2" PLYWOOD SHEATHING RIDGE VEN)' cont. 2"x10" RIDGE 2"X8' RAFTER 16"0,E INSULATION LATION (t),lP.) OUR NEW SLAB /~TO MATCH EXISI)NG BUILD NEW ROOF ~COMPACTED SUB-BASE INSULATfON ASPHALT ROOF SHINGLES OVER 15 L~. FELT OVER 1/2" PLYWOOD SHEAllHING INSULATION 5/8" ¢ ANCHOR BOLTS O 3'-0" O.C. SECTION "B"-"B" SCALE 1/4" = 1' REVISION DATE SECTIONS AND DETAILS LOCATION: 2950 ROCKY POINT RD. OWNER: MR CONWA Y ALLIED BUILDERS CUSTOM REMODELING MAIN ROAD, ORIENT, NY 11957 EDWARD J. CEBUL DESIGN DEN ENGINEERS, PLANNERS. DESIGNERS 6 HOWE ROAD, CORAM, NEW YORK 11727 PHONE & FAX (631) 698--4257 SHEET 3 OF DRAWN BY: EJC SCALE: AS NOTED PROd No. 08051 CHECKED BY: SP FILE: DATE: OCT. 2008 5 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE TYPE OR LOCA110NS OF CONCRETE CONSTRUCTION Basement walls, foundations and other concrete not exposed to the weather 2,500c Basement slabs and interior slabs on grade, except garage floor slabs 2,500c Basement walls, foundation walls, exterior walls and other vertical concrete work exposed to the weather 5,000d Porches, carport slabs end steps exposed to the weather, and garage floor slabs For SI: 1 pound per square inch = 6.895 kPa. a. At 28 days psi b. See Table RRB01 2(1) for weathering potential. MINIMUM SPEARED COMPRESSIVE S~ENGTHa(t'C) Weathering potentialb Severe 5,500d,e c. Concrete in these locations that may be subject to freezing and thawing during construction shall be air-entrained concrete m accordance with Footnote d. d. Concrete shall be air entrained. Total air content (percent by volume of concrete) shall not be less than 5 percent or more than 7 percent. e. See RR402.2 for minimum cement content. ROOFING NOTES: Asphalt strip shingles shall have a minimum of six fasteners per shingle in the 110-120 mph wind zones R9905.2.7.1 Ice protection. In areas where the average daily temperature in January is 25T (-4'C) or less or when Table R9501.2(I) criteria so designates, an ice barrier that consists of a least two laysrs of underla~ment cemented together or of a self-adhering polymer modified bitumen sheet, shall be used in lieu of non. el undeda~rnent and extend from the cove's edge to a point at least 24 inches (610 mm) inside the exterior wag line of the building. R9905.2.7 Underlayment applicabon For roof slopes from 1we units vertical in 12 units horizontal (17-percent slope), up to four units verbcal in 12 units hm'izonta~ (33-percent slope), undeda~rnent shall be two Joysrs applied in the following manner. Apply a 19-inch (485 mm) strip of underlayment felt parallel with and starting et the eaves. fastened sufficiently to hold in place. Starting at the cave, apply 56- inch-wide (914 mm) sheets of undeda~ent, overlapping successive sheets 19 inches (483 mm), and fastened sufficiently to hold in place For roof slopes of four units ve~ticel in 12 units horizontal (35-percent slope) or greater, underla~nent shall be one layer applied in the following manner. Underla~ment shall be applied shingle fashion, parallel to and starting from the eave and lapped 2 inches (51 mm), fastened sufficiently to hold in place End laps shall be offset by 6 feet (1829 mm). PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALS CLASS OF MATERIAL Sandy grovel end/or gravel (GW and GP) Sand, silty sand, clayey sand, silty grovel and clayey gravel (SW, SP, SM, SC, GM and Ge) Clay, sandy clay, silty clay, clayey silt, silt and sandy silt (CI, ML, MH and CH) LOAD-BEARING PRESSURE (pounds per square foot) 3,000 2,000 1.500b §R9905.2.8 Flashing Flashing for asphalt shingles shall comply with this section. §RR905.2.8.1 Base and cap flashing Base and cap flashing shall be installed in accerdance with manufacturer's installation instructions. Base Bashing shall be of either corrosion-resistant metal of minimum nominal O.019-inch (0.483 mm) thickness or mineral surface roll roofing weighing a minimum of 77 pounds per tO0 square feet (3.76 kg/m2). Cap flashing shall be corrosion-resistant metal of minimum nominal O.019-inch (0.485 mm) thickness. §R9905.2.8.2 Valle, ye. Valley linings shall be iastalled in accordance with manufacturers installation instructions before applying shingles. Valley linings of the following types shall be permitted: 1 For open valley (valley hning exposed) lined with metal, the volley lining shall be at least 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R9905.2.8.2. 2. For open valleys, valley liniag of two plies of mineral surface roll roofing, compyng with AS~I D 249, shall be permitted. The bottom Ioysr shall be 18 inches (¢57 mm) and the top layer a minimum of 56 inches (914 mm) wide. 5. For closed valleys (volJey covered with shingles), valley lining of one ply of smooth rol~ roofing compyng with ASTM D 224 Type II or Type UI and at least 56 inches (914 mm) wide or valley lining as described in Items 1 and 2 above shall be permitted. Specialty underloyment complying with AS1MD 1970 may be used in lleu of the lining material. TABLE R9905.2.8.2 VALLEY LINING MATERIAL MINIMUM IHICKNESS WEIGHT MATERIAL (inches) GAGE (pounds) Copper .... Aluminum 0.024 -- Stainless steel -- 28 Galvanized 26 (zinc steel 0.0179 coated Zinc alloy 0.027 Lead .... Painted terne .... 2-1/2 20 For SI: 1 inch = 25.4 mm, 1 pound = 0.4,5~- kg. §R9905.2.&5 Crickets and saddles A cricket er saddle shall be installed on the ridge side of any chimney greater than 50 inches (762 mm) wide Cricket or saddle coverings shall be s~eet metal or of the same material os the roof covering. §RR905.2.8.4 S~dewall flashing. Flashing against a vertical sidewall shall be by the step-flashing method. {R9905.2.8.5 Other flashing. Rashlng against a vertical front wall, as well as soil stack, vent pipe and chimney flashing, shall be applied according to asphalt shingle manufacturer*s printed instructions. CODE COMPLIANCE DESIGN CRITERIA American Forest and Paper Association (Ar&PA) "WOOD FRAME 1995 HIGH WIND EDISON CONS~UCTION MANUAL FOR ONE AND TWO FAMILY DWELLINGS" and the "RESIDEN~AL CONS~UCTION CODE OF NEW YORK STATE. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA (TABLE 301.2(1) SUBJECT TO DAMAGE FROM GROUND WIND SEISMIC WEAk,HER- FROST Wr~R iCE S]UELD FLOOD SNOW SPEED DESIGN lNG LINE YERMITE DECAY TEMP [JNDE~LAYMENT LOAD (mph) CATEGOR'~ DEPTH DF31GN HAZARDS 9501.2 (5) 9301.2 (4) 8301 2 (2) fl301.2 (5) t301.2 (6) 9301.2 (7) REQUIRED 120 Mod. to ~n accordance w/ 4`5 PSF MPH C Severe 36" heavy Slight 11' sec 905.2.7.1 N/A FASTENER SCHEDULE FOR STRUCTURAL MEMBERS NUMBER AND TYPE OF DESC. OFBUILDING ELEMENTS FASTENER SPACINGOFFASTENERS FASTENER SCHEDULE FOR STRUCTURAL MEMBERS (conrd) DESCRIPTION DESC. OF BUILDING MATERIALS OF SPACING OF FASTENERS Joist to sill or girder, toe nall joist, face nail 2' subfloor to jolt or girder, bgnd and face nail Sole plate to joist or blocking, face nall Top or sole plate to stud, end nail Stud to sole plate, toe nail Double studs, face nail Double top plates, face nail Sole plate to joist or blocking at braced wall panels Double top plates, minimum 4,8-inch offset of end joints, face nail in lopped area Btacking between joists or rafters to top plate, toe nail Rim joist to top plate, toe nail Top plates, laps at corners and intersections, face nail Built-up header, two pieces with ti2' spacer Continued header, two pieces Ceiling joists to plate, toe nail Continuous header to stud, toe nail Ceiling joist, lops over partitions, Ceiling joist to parallel rafters, lace nail gaffe' to plate, toe nail 1" x 6' sheathing to each bearing, face nail I" x 8' sheathing to each bearing, face nail Vfider than 1" x 8' sheathing to each bearing, face nail Built-up corner studs Built-up girders end beams, 2-inch lumber layers 2 staples, 16d 16" o.c. or 2-t6 10d 24' o.c. 8d 16d 5-8d 4-8d 2-8d 2 staples, 2-8d 2 staples, 2-8d 5 staples, 1-3/4 3-8d 4- stapres, 1Od 1Od 19/32 - 1 1-1/8 - 1-1/4 MATERIALS Other wall sheathing (hi 1/2" regolar cellulosic fiberboard sheothlng 5/8 gypsum sheathing along each edge along each Intermediate Edges supports 24" o,c. Noil eoch Ioysr os follows: 32' o.c, 2" plonks 2-16d Root rafters to ridge, wiley or hip rafters: toe nail 4,-16d face nall 3-16d Rafter ties to rafters, face 3-8d -- Wood structural panels, subfloor, roof and wall sheathing to fromlng, and particleboard wall sheathing to framing 5/16 - 1/2 6d common nail 6 (subfloor, wall) 8d common nail 6 (rooOf 8d common nail 6 10d common nail or 6 8d deformed hall (b,c,d,e) (ii (inches) 1-1/2 galvanized roofing 3 hall 6d common nail staple 16 go., I-1/2 long 1/2 structural cellulosic 1-1/2 galvanized roofing 3 fiberboard sheathing nail 8d common nail staple 16 ga., 1-1/2 long 25/32 structural 1-3/4, galvanized roofing 3 cellulosic fiberboard nail 8d common nail sheathing staple 16 ga., 1-3/4, long 1/2 gypsum sheathing 1-1/2 galvamzed roofing 4 nail; 6d common nail; staple galvanized, Type W or S 1-3/4 galvanized reofing nail; 8d common nail; staple galvanized, 1-5/8 long; 1-5/8 screws, edge Type W or S Wood structural panels, combinotiofl subfloor underla~nent to framing 3/4 and less 6d deformed nail or 6 8d common nail 7/8 - 1 8d cornmon nail or 6 8d deformed nail 8d deformed nail 12 REVISION DATE (551 Mpa) for shank diameter of 0.192" (20d common nail), 90 ksi (620 0.177", and 100 kel (689 Mpa) for shank diameters of 0.14,2" or less. supports where spans are 48 inches or greater. At each bearing Table RR602.3(1) E For regions ha~ing basic wind speed of 110 mph or greater, 8d deformed end wails, if mean roof height is more than 25 feet, up to 55 feet 129 attaching wood structural panel roof sheathing to gable e~d wall 129 on center to gable end wall framing. CODE COMPLIANCE LOCATION: 2950 ROCKY POINT RD. OWNER: MR CONWA Y ALL/ED CUSTOM MAIN ROAD. EDWARD J. BUILDERS REMODELING ORIENT, NY I 1957 CEBUL SHEE~ DESIGN DEN ENGINEERS, PLANNERS, DESIGNERS ~- 6 HOWE ROAD, CORAM, NEW YORK 1 1727 PHONE & FAX (631) 698--~-257 OF DRAWN BY: EdC SCALE: AS NOTED PROJ No. 08051 CHECKED BY: SP FILE: DATE: OCT. 2008 J CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA ITABLE 301.211) SNOW DESIGN FROST UNE DESIGN UNOERLA'~.JENT FLOOD LOAD SIO[ED {UpRI CAI1EG~RY 'IEATH[RIR6 DEPTH TERMI~ DECAY TEMP. REQUIRED HAZARDS ~301.2 (5] R301.2 (4) ~301.2 (2) R501.2 (3) R301 2 (6) R30 2 (7: R905.2.7.1 NAILING SCHEDULE FROM IAK~OD FRAME CONSTRUCTION bIANUAL, 1995 ED JoiNY OESCR,P"ON I:=ENDE I ?.% I R%NG I Z' I ROOF FRAMING RAFTER TO TOP PLATE TABLE 5.5A 3-8d PER RAFTER 288 LBS, 102 LBS. (TGE NAILED) CEILING JOIST TO TOP TABLE 5.SA 5-Sd PER JOIST 286 LBS* 102 LBS PLATE (TOE NAILED) CEILING JOIST TO TABLE 3-7 6--1Hd EACH LAP ~44 LBS. 187 LBS. PARN_LEL RAFTER (FACE-NAILED) CEILING JOIST LAPS TABLE 3-7 H-16d EACH LAP 44-4 LBS. 187 LBS. O~ER PAR~ISIONS (FACE-NAILED) COLLAR 3TE TO TABLE 3-4 4--8d PER 31E 252 LBS. g9 LBS. RAFTERS (FACE-NAILED) DLOCKING TO RAFTER 2-8d EACH END 192 LBS 68 LBS. (TOE NAILED) RIM HOARD TO RAFTER 2-16d EACH END 256 LBS. 0 L~S. (END NAILED) WALL FRAMING TOP PLATE TO TOP PLATE 2-16d (1) PER FOOT 296 LBS. 125 LBS. (FACE NAILED) TOP PLATES AT INTERSECTIONS 4-16d JOINTS - EACH SiDE 592 LBS, 250 LBS. (FACE NAILED) STUD TO SS1JD (FACE NAILED) 2-16d 24-"0,C. 296 LBS. i 25 LBS. HEADER TO HEADER (FACE NNLED) 16d 16' O.C ALONG 9)CES 14-8 LBS. ! 62 LBS. TOP OR BOTTOM PLATE 2-16d PER 2X4- STUD 256 LBS, ! 0 LBS. TO STUD ( END NAILED) 5-16d PER 2X6 SI~JD 584- LBS. 0 LBS · -16d PER 2XH STUD 512 LBS. 0 LBS BOTTOM PLATE TO FLOOR JOIST 2-16d (1,2) PER FOOT 582 LBS. 164 LBS BAND JOIST ENDJOIST OR BLOKING (FACE NAILEO) FLOOR FRAMING (TO{[ NAILED) BLOCKING TO JOIST 2-Sd EACH END 192 LBS. 68 LBS (TOE NAILED) JOIST ON LEDGER TO BEAM 3-Sd PER JOIST 286 LBS. 102 LBS, (TO~ NAILED) BANDJOIST TO S~LL OR 2-16d0) PER FOOT 316 LBS. 118 LBS. TOP PLATE (TOE NAILED) NAILING SCHEDULE FROM WOOD FRAME CONSTRUCTION MANUAl., 19~5 ED J N DESOR,P ON I:=ENCEI OF NAILS SPACING FLQOR SH EATHIN~ STRUCTURAL PANELS I I6" EDGES/12" RELD 153 LBS, PER SUPPORT 226 LBS. I PER SUPPORT 539 LBS. PRESUMPTIVE i~OAD-BEARING VALUES OF FOUNDATION MATERIALS LOAD--BEARING PR CLASS OF MA~RIAL pounds per square foot) TABLE 602A2 (SSTD 10-99) DESIGN WIND LOAD FOR WINDOWS AND DOORS (psf) ~31N BUILDINGS WITH A MEAN ROOF HEIGHT (MRH)~ OF 30 FEET W/BASIC WIND SPEED ~OF 110 mph I~ ~F IIDOW ~ ~t A ~ ~T.) POS (+) RES (-) NEC (-) 0 < A < 25 39 -39 -45 25 'C A < 50 37 -38 -42 50 ~. A < 100 35 -37 -40 100 ~ A < 200 34 -36 -38 200 ~. A 32 -35 -36 REVISION TABLE 301.4 MINIMUM UNIFORMLEY DISTRIBUTED LIVE LOADS USE LIVE LOAD EXSERIOR BALCONIES 60 DECKS 40 PASSENGER VEHICLE GARAGES o 50 a ATRCS ~PHOUT STORAGE 10 ATTICS W/ STORAGE 20 ROOF LOAD (SNOW LOAD CONVERSION) (AS PER ASCE 7-98 SECTION 7 0) ( R501.2~51 Y P, = .7(.9)(1)(1)(4§~8.3S Cs = .85 24 ~ + 10(a.) = 34 I..B~rr. TABLE 301.6 A~LOWABLE DEFLECTION OF STRUCTURAL MEMBERS ALLOWABLE STRUCTUP~J- MEMBER DEFLECTION RAFTERS HAVING SLOPE GREATER THAN L/180 3/12 W/ NO FIN. CEIUNG ATTACHED INTERIOR WALLS AND PARtitIONS H/lBO FLOORS AND PLASTERED CEILINGS L/360 STRAPPING & ANCHORING SCHEDULE (BASEMENT) TITLE SHEET LOCATION: 2950 ROCKY POINT RD. OWNER: MR CONWA Y ALL/ED t UILD£RS CUSTOM RP'MODELING MAIN ROAD, ORIENT, NY 11957 EDWARD ~. CE~U~ DESIGN DEN IY[i\~.~*~ ~ ENGINEERS, PLANNERS. DESIGNERS 6 HOWE ROAD. CORAM, NEW YORK 11727 SHEET OF No. 5