Loading...
HomeMy WebLinkAbout35236-ZTown of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 4/23/2012 CERTIFICATE OF OCCUPANCY No: 35554 Date: 4/23/2012 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: ADDITION/ALTERATION 7345 SOUNDVIEW AVE SOUTHOLD, Sec/Block/Lot: 59.-6-5.2 Filed Map No. conforms substantially to the Application for Building Permit heretofore 12/23/2009 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: conversion of decks and front stoop to living space on an existing one family dwelling as applied for. Lot No. filed in this officed dated 35236 dated 12/23/2009 The certificate is issued to ZBIGN1EW & ANNA KOZLOWSKI (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 2082715 5/1/06 Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35236 Z Date DECEMBER 23, 2009 Permission is hereby granted to: ZBIGNIEW & ANNA KOZLOWSKI 7345 SOUNDVIEW AVE SOUTHOLD,NY 11971 for : ALTER3tTION & ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS at premises located at County Tax Map No. 473889 Section 059 pursuant to application dated DECEMBER Building Inspector to expire on JUNE 7345 SOUNDVIEW AVE SOUTHOLD Block 0006 Lot No. 005.002 23, 2009 and approved by the 23, 2011. Fee $ 250.00 / - - v Aufhorized~lgnature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. ~5..6 Date SEPTEMBER 19, 2005 Permission is hereby granted to: ZBIGNIEW & ANNA KOZLOWSKI 7345 SOUNDVIEW AVE SOUTHOLD,NY 11971 for : ALTERATION & ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR; FLOOD PERMIT INCLUDED at premises located at County Tax Map No. 473889 Section 059 pursuant to application dated AUGUST Building Inspector to expire on MARCH 7345 SOUNDVIEW AVE Block SOUTHOLD 0006 Lot No. 005.002 22, 2005 and approved by the 19, 2007. Fee $ 250.00 Rev, 5/8/02 ORIGINAL Form No. 6 TOWN OF SOUTItOLD BUILDING DEPARTMENT TOWN HALL 765-1802 OCC APPLICATION FOR CERTIFICATEOF This application must be filled iu by typewriter or ink and submitted to the Building Department with the foI~wing: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. Submit Plamfing Board Approval of completed site plan requirements. 1. Accurate survey of property showing all property lines, streets, building and unusual uatural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupaacy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Connnercial $15.00 New Construction: Old or Pre-existing Building: Location of Property: __ }louse No. Street Owner or Owners of Property: ~B/N.,t- 2d~/~ A) [~C~fA.J Suffolk County Tax Map No 1000, Section o~'q Subdivision -7~ <>-'~.~ ~ ~ Date.__ ~f,2t~_/,_f-~ (check oue) Block Filed Map. Hamlet Lot: PermitNo._ .~t~_ .,~ ~. DateofPcnnit. ~C~[Z2[O~- Applicant: Health Dept. Approval: i-/~?~- 0 3~t~,{~[~ Underwriters Approval: Plamfing Board Approval: .~ CT[U[ ~ 1~0~--)''~ ,5'(-[~- ~.~--.~'. ~ Request for: Temporary Certificate Final Certificate: x,~ Fee Submitted: $ (check one) Applicant Signature BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by SJ O'CONNOR ELEC. CONTR. 1195 SHIPS DRIVE SOUTHOLD, NY 11971 ZIGGY KOZOLWSKI 7345 SOUNDVIEW AVE SOUTHOLD, NY 11971 Located at 7345 SOUNDVIEW AVE SOUTHOLD, NY 11971 Application Number: 2082715 Certificate Number: 2082715 Section: Block: Lot: Building Permit: BDC: ns11 Described as a Residential 0-599 square fi. occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Second Floor, Attached Garage, Outside, Porch/Deck, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the 1st Day of May, 2006. Name QTY Rate Rating Circuit Type Miscellaneous 2nd floor addition-service & patio Alarm and Emergency Equipment Sensor 3 0 Wiring and Devices Outlet 12 0 Fixture 12 0 Outlet 16 0 Receptacle 11 0 Switch 7 0 Paddle Fan 2 0 Service 1 Phase 3W Service Rating 150 Amperes Service Disconnect: 1 150 Meters: I Smoke Fixture Incandescent General Purpose General Purpose General Purpose cb seal 1 of 1 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING ~ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE ~-~ ~'~ . INSPECTOR__~~-- ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]RRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE 13 To: Town of Southold JAMESJ. DEERK()SKI, P.E. 260 Deer Drive Mattimck, N.Y. 1195~2 (631) 298-7116 Re: Stral)l)inffFrmning/Phnnbing InsI)cction Kozlowska 734,5 Soumlvicw Ave. Southold, NY 11!)71 To Whom h May Coll¢Crll: This loiter ecrlifics that all wind straI)lfir~g on thc above mentioned I)rqjcct is in tact, and meets all statc m~(l local building codes. A Framin~Plumbing Ii]spcclion was :-ds() Pcffornmd on this Slrucmrc, and 'all framing and Phlmlfing was done corrcclly mul als() mccts all state and local building codes. A prcssurc test was als() pcrtbrmcd on Ihe wastc/watcr phlmbing systems. Any questions plcasc lk'¢l l?ec to call. Jal%~~koski I'.E. JAMES.|. DEERKOSKI, P.E. 260 Deer Drive Matfituck, N.Y. 11952 (631) 298-7116 ]daa&- To: Tom~ of Soutl~old Re: S trapping/Frmning/Plumbing Inspection Kozlowska 7345 Soundview Ave. Southold, NY 11971 Permit# 31~6Z ~S ~.5~,' To Whom It May Concern: This letter ccrtifies that all wind straI)piug on the above inentioned project is in tact, va~(t meets all state m~d local building codes. A Framing/Plumbing Inspection was also Performed on tiffs Structure, and all franfing and Plumbing was done correctly m~d also meets all state and local building codes. A pressure test was also performed on the waste/water plumbing systems. Any questions please t~cl free to call. J~~koski P.E. JAMES J. DEERKOSKI, P.E. ~260 Dccr Drive Mattimck, N.Y. 1195~ (631) '298-7116 To: Tovm ol'Southold To '¢,Zhom h Ma)' Concern: An Insulation Insl)cctiol~ ,,vas l)rcli)rmc(l at thc abovc mcntioncd property, 'all insulation was installcd as pcr Plan m~(1 meets 'all State and local Building Codes. Any questions plcasc fccl l?cc to cml. Sinccrcly james J. De&~)ski I'.E. JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattimck, N.Y. 11952 (631) 2!t8-7116 To: Town o1' Southold Re: First & Second Foundation Inspections Kozlowska 734.5 Soundvicw Ave Southold, NY 11901 Permit# ~'~6z g~-~L To Wholll It May CollCerll: This letter ccrtitles that a lirst & second lbundation inspections were l)rcformcd ()il IBc al)ore mentioned property and was all done correctly and meet all stale vmd local lmilding eodcs. Any questions please lkcl ti'cc to call. FIELD INSPECTION REPORT i DATE COMMENTS ~ ~ FOUNDATION (2ND) ~'~ FIN~ ~DITION~ COMMENTS ~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HA[eL SOUTHOLD, NY 11971 TEL: (6,31) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined Approved Disapproved a/c Expiration ,¢/t' ? ,20v7 PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey_ Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: Phone: /Building Inspector APPLICATION FOR BUILDING PERMIT Date O0 ,?~ ,200'~-- INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new perrrfit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the constmction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sqgnature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises o~/3/~/a?~j /</zsvz~/O~s3~/ (As on the tax roll or latest deed) if applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section ~- c/ Block Subdivision Filed Map No. 2. State existing use and ~ccupancy ~f premises and intended use and ~ccupancy ~f pr~p~sed c~nstructi~n: a. Existing use and occupancy b. Intended use and occupancy Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars Addition ~ Alteration Other Work Fee (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Number of Stories Rear _Depth Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories Rear 8. Dimensions o f entire new construction: Front Height Number of Stories Rear Depth 9. Sizeoflot: Front /)*-3 ' Rear 12'5, ~f Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES__ NO__Will excess fill be removed from premises? YES NO 14. Names of Owner of premises e r~/~,~£,~ I.(o2[,~/~ Address 73vr ~ac_e~,_z- Phone No. Name of Architect Address Phone No Name of Contractor _~'. 5'~../~,r~. r~s~/ Address)~,r~,~ /~J7 ~Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) COUNTY OF , '~ ~¥x ,¢,~o KO "l~\ 0 ~ ~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the ~ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to be~re me this dayof ~ 20 O_~ Notary P~lic /- Signature of Applicant Board Of $outhold Town Trustees SOUTHOLD, NEW YORK PERMIT NO...~.! .......... ISSUED TO ZBZON~EW KOZL0WSKI Pursuant to the provi[ions of Chapter 615 of the L~ws of the State of New York, 1893, and CJ~apter 404 of the ~ws of the State of New York 19521 and the Southold ToWn Ordinance tiffed ?REGULATING AND THE PLACING OF OBSTRUCTiQNS IN AND ON TOWN WATERS AND PUBLIC LANDS and the REMOVAL OF SAND, GRAVEL'OR OTHER MATERIALS~F. ILOM LANDS .UNDER TOWN WATERS:IL and in accordance wlfJ~ The Resoldlon of The Board adopted at a meeting held on .20..°...5......, and in consideration of the sum of $.._:~.~.~.:.P.0 ....... paid by .................... ~.~.~.-5.~?~...~..o..~.~.~ ~..k..~-. .............................................................. ., ........... ~ ......... of ......... ~.q.~.~.~P.~ ....................................................... N, Y. and. subject fo the Terms and Conditions listed on the reverseside hereof, of Southold Town' Trudees authorizes and permits the following: Wetland Permit to expand the existing single-family dwelling by converting decks and the fron~ stoop into interior living space, amd mll as depicted~ on the survey prepared 'by John ~. Metzger last dated August 25, 2004. all in accordance with the deta~d specifications as presented in .the orlg;nafing appl'm, afion. IN WITNESS WHEREOF, The said Board Of Trustees here- by causes ifs Corporate Seal to. be a~xed, and these ~.resenfs fo be subs~'bed by 'a 'majority of the satd Board .as of thee date. James F. King, President Jill M. Doherty, Vice-President Peggy A. Dickerson Dave Bergen Bob Ghosio, Jr. Town Hgll Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 0508C Date: January 19. 2010 THIS CERTIFIES that the cxoansion of the e~!.~tin~ dw¢llin? by convertin~ decks and front stoop into interior livina soaco At 7345 Soundview Avenue, Southold, New York Suffolk Co~mty Tax Map # 59-6-5.2 Conforms to the applications for a Trustees Permit heretofore filed in this office Dated 12/29/04 pursuant to wlflch Trustees Wethmd Permit # 6061 Dated 1/19/05 was issued eouforms to all of the requirements and conditions of the applicable provisions of law, The project for which this certificate is being issued is for the expansion of©xisting dwelline bv convertin~ decks and front stony into interior livin~ snace The certificate is issued to Zbianiew Kozlowski owner of the aforesaid property.' Authorized Signature NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DEC PERMIT NUMBER 1-4738-03360/00001 FACILITY/PROGRAM NUMBER(S) PERMIT Under the Environmental Conservation Law EFFECTIVE DATE 16 November 2004 EXPIRATION DATE(S) 30 November 2009 TYPE OF PERMIT · New [] Renewal El Modification [] Permit to Construct [] Permit to Operate [] Article 15, Title 5: Protection of Waters [] 6NYCRR 608: Water Quality Certification [3 Article 27, Title 7; 6NYCRR 360: Solid Waste Management [] Article 15, Titla 15: Water Supply [] Article 15, Title 15: Water Transpod [] Article 15, Title 15: Long Island Wells [] Adicle 15, Titla 27: Wild, Scenic and Recreational Rivers [] Article 17, Titles 7, 8: SPDES [3 Article 19: Air Pollution Control [] Adicle 23, Title 27: Mined Land Reclamation · Article 24: Freshwater Wetlands [] Adicle 25: Tidal Wefiands [] Article 27, Title 9; 6NYCRR 373: Hazardous Waste Management [] Article 34: Coastal Erosion Management [] Article 36: Floodplain Management [] Articles 1, 3, 17, 19, 27, 37; 6NYCRR 380: Radiation Control SSUED TO I TELEPHONE NUMBER I 631-765-5040 -ADDRESS OF PERMITTEE 7345 Soundvlaw Avenue, Southold, NY 11971 CONTACT PERSON FOR PERMI~I'ED WORK I TELEPHONE NUMBER \NAME AND ADDRESS OF PROJECT/FACILITY 7345 Soundview Avenue, Southold SCTM: 1000-059-06-5.2 COUNTY I TOWN Suffolk Southold DESCRIPTION OF AUTHORIZED ACTIVITY: IWATERCOURSE I NYTM COORDINATES Great Pond E: 713.9 N: 4549.0 Expand the existing single family dwelling by converting decks and the front stoop into interior living space. InsT~all an additional drywell to capture roof runoff. All work is to be done in accordance with the attached plans stamped NYSDEC approved. By acceptance of this permit, the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations, the General Conditions specified (see page 2 & 3) and any Special Conditions included as part of this permit. PERMIT ADMINISTRATOR: George W. Hamrearth, Deputy Permit Adreinstrator ADDRESS Region 1 Headquarters Bldg. #40, SUNY, Stony Brook. NY 11790-2356 DATE Page 1 of 4 /O~a-,,.~-~-~TOWN OF SOUTHOLD pROpERTY RE¢:ORD CARD OWNER STREET~ 7(-~ ~5 VILLAGE I DIST. SUB. LOT ~ES.~/~ J S~S. VL. FA~ COMM. CB. MISC. Mkt. Value / ~ND IMP. TOTAL DATE REMARKS Tillable 3 Woodland Br~kland FRONTAGE ON ROAD ~ouse Plot DEPTH Total DOCK ~. BI~. Extension Extension PoKo'.l- Breezeway Garage Patio Total COLOR Foundation ~7~1Basement IExt. Walls ~./~d:ire Place /~' oITyp~ Roof IRecreation Room / Bath Floors Interior Finish Heat Rooms 1st Floor Rooms 2nd Floor Dinette LR. DR. BR. FIN. B. ~d'Q~D°r.mer Driveway Town Hall Annex 54375 Main Road P.O. Box 1179 Southold. New York I 1971-0959 Telephone (631 ) 765-1802 Fax (631 ) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD 1ST NO'ITCE October 22nd, 2008 Zbigniew & Anna Kozlowski 7345 5oundview Avenue 5outhold, NY 11971 7345 5oundview Ave. (Addition/Alteration) 5CTM # 59.-6-5.2 bear Mr. & Mrs. Kozlowski, Please be advised that your Building Permit # 31456 issued 5eptember 19th, 2005 has expired. According to the Code of the Town of 5outhold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit please submit a fee of $250.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions please call us at 631-765-1802 Respectfully, 5outhold Town Building bept. Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-(}959 Telephone(631)765-1802 Fax(631)765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD November 26th, 2008 Zbigniew & Anna Kozlowski 7345 5oundview Avenue 5outhold, N.Y. 11971 2nd NO'TZCE RE: 7345 5oundview Ave. (Additions/Alterations) 5CTM: # 59.-6-5.2 bear AAr. & ~Ars. Kozlowski, Please be advised that your Building Permit # 31456 issued September 19th, 2005 has expired. According to the Code of the Town of 5outhold, a Certificate of Occupancy must be issued before the use of the structure. To renew your Building Permit, please submit a fee of $250.00; at time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 765-1802. Respectfully, 5OUTHOLD TOWN BUILDINfi DEPT Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD ,Tanuary 12*h, 2009 Zbigniew & Anna Kozlowski 7345 5oundview Avenue 5outhold, N.Y. 11971 FINAL NOTICE RE: 7345 5oundview Ave. (Additions/Alterations) 5CTM: # 59.-6-5.2 bear Mr. & Mrs. Kozlowski, Please be advised that your Building Permit # 31456 issued September 19th, 2005 has expired. According to the Code of the Town of 5outhold, a Certificate of Occupancy must be issued before the use of the structure. To renew your Building Permit, please submit a fee of $250.00; at time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 765-1802. Respectfully, 5OUTHOLD TOWN BUILDING DEPT cc; code enforcemenf cc; legal deporlmenf Tclcllhom' (631) 763-180~2 Fax (6;11) BI ,ILl)IN(, I)I~;PAIITMI:,NT TOWN OF SOUTHOLD December 21st 2009 Zbignew & Anna Koslowski 7345 5oundview Avenue 5outhold, N.Y. 11971 Re: 7345 5oundview Ave. / Violation 5¢TM# 1000-59.-6-5.2 To Whom This May Concern: Your BUILDING PERM~I' # 31456 for construction of an ALTERATIONS & ADDrr~oN5 has been referred to me because you have not responded to requests to obtain your Certificate of Occupancy as required by 5outhold Town code. Pursuant to 144-15A, of the 5outhold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Tnspector.' Therefore, you have ten days from the receipt of this letter to submit a check made out to the Town of $outhold in the amount of $2~0.00: to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Damon Rallis, Zoning Inspector 5outhold Building Department Town Hall Amwx a 1375 Main Road P.(). Box 1 St)udlold, ~Y IIPTI 09,~9 Tdcphonc (631 ) 765- I l'ax (631) 7 BI!ILl)IN(; 1)EI'ARTMISNT TOWN OF $OUTHOLD December 29, 2009 Zbigniew Kozlowski 7345 Soundview Avenue Southold, NY 11971 TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Building Permit: Electrical Underwriters Certificate. A fee of $25.00. Final Health Department approval. Plumbers solder certificate (all permits involving plumbing after 4/1/84.) Trustees Certificate of Compliance. Final Planning Board Approval. Final Fire Inspection from Fire Marshal. Final inspection from the Building Department. Final Landmark Preservation approval. 35236-Z addition/alteration Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 March 19, 2012 BUILDING DEPARTMENT TOWN OF SOUTHOLD Anna & Zbigniew Kozlowski 7345 Soundview Ave Southold, NY 11971 TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupanc __ Application for Certificate of Occupancy. (Enclosed) __ Electrical Underwriters Certificate. (contact your electrician) 'J A fee of $25.00. (outdated check enclosed) __ Final Health Department Approval. ~-Fl'~ers Solder Certificate. ' ~:..~.~;.~ (All perm ts mvu,.,,,~ ~..~!!~_~,...__ __ Trustees Certificate of Compliance. (Town Trustees # 765-1892) __ Final Planning Board Approval. (Planning # 765-1938) __ Final Fire Inspection from Fire Marshall. __ Final Landmark Preservation approval. BUILDING PERMIT: 35236 - Addition/Alterations Permit Number Checked By/Date REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSoflware Version 3.6 Release 1 Data filename: C:LProgram Files\Check~REScheckUENSEN.rck PROJECT TITLE: ADDITION COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached ! or 2 Family HEATING TYPE: Nan-Electric WINDOW/ WALL RATIO: 0.23 DATE: 02/23/05 DATE OF PLANS: 02/2005 PROJECT DESCRIPTION: EDWARD JENSEN SUNSET WAY RD. SOLrI~OLD, NY COMPLIANCE: Passes Maximum UA = 396 Your Home UA = 395 0.3% Better Than Code (HA) Gross Glazing Area or Cavity Com. or Door Perimeler R-V~ue ~ U-Factor UA Ceiling 1: Cathedral Ceiling (no attic) 1314 30.0 0.0 45 Wall 1: Wood Frame, 16" o.c. 1052 15.0 0.0 60 Window 1: Wood Frame:Double Pane with Low-E 232 0.350 81 Door 1: Solid 44 0.350 15 Wall 2: Wood Frame, 16" o.c. 1160 21.0 0.0 51 Window 2: Wood Frame:Double Pane with Low-E 228 0.350 80 Door 2: Glass 39 0.340 13 Floor 1: All-Wood Jois~Truss:Over Unconditioned Space 955 38.0 0.0 25 Floor 2: Ail-Wood Joist/Truss:Over Outside Air 977 38.0 0.0 25 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance with this Code. REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.6 Release 1 DATE: 02/23/05 PROJECT TITLE: ADDITION Bldg. Dept. Use [ ] [ ] [ I [ I [ ] [ ] [ ] [ ] [ ] [ ] [ 1 Ceilings: 1. Ceiling 1: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: 2. Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break7 [ ] Yes [ Comments: ] No Window 2: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes Frame Type_ Thermal Break? [ ] Yes [ Comments: ] No 1. Door 1: Solid, U-factor: 0.350 Comments: 2. Door 2: Glass, U-factor: 0.340 Conunents: Floors: 1. Floor 1: All-Woed Joist/Tress:Over Unconditioned Space, R-38.0 cavity insulation Comments: 2. Floor 2: All-Wood JoistfFruss:Over Outside Air, R-38.0 cavity insulation Comments: Air Leakage: Joints, penetmtions, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1 ) Type IC mted, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. 1 [ ] [ 1 [ ] [ I [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ I [ ] [ ] [ I [ I [ ] [ ] Vapor Retarder: Required on the warm-in-winter side of ail non-venWxl framed ceilings, wails, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materiais and equipment must be identified so that compliance can be determined. Manufacturer manuals for ail installed heating and cooling equipment and service water heating equipment must be provided. Insolation R-values and glazing U-faetors must be clearly marked on the building plans or specifications. Duct Insolation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Remm ducts in unconditioned spaces (except basements) must be insulated to R- Return ducts in unconditioned spaces (except basements) must be insulated to R-2.. Insolation is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 18lA or UL 18lB. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for. each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-oombustible fireplace doors. Fireplaces must be provided with a source of oombustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is pan of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insolate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thiekne~ in lnchea by Pine Sizes Hea~ed Water N n- ir 'n Circulatine Mains and Runoms ~ Un to 1" Un to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipe& Fluid Temp. Insulation Thickness in Inches bv Pine gi?eg Pinine System T _vpes Ranee (FI Heating Systems Low Pressure/Temperature 201-250 Low Temperature 120-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant, 40-55 and Brine Below 40 2" Runouts ~ 2.5" to 4" 1.0 1.5 1.5 2.0 0.5 L0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) !'ii ADDITION TO rl 000 rlClO 000 :I : 000 or'to flor1 000 000 OhO FRONT ELEVATION SCALE: 1/4" = 1'-0" l,, cERTIFICATION OF L_F__FT ELEVATION I~OOD ZO~Z¢~ NoT~ SUlLO,.~ AT 0 765-1802 8AM TO 4PM FOR ~E ~M pLy WIT~ CHAPTER "46" FOLLOWING ~NSPECTIONS: ,:, R DAMAGE PREVENTION 1. FOUNDATION - ~O R~UIRED FOR POURED CONCR~E , m_D TOWN CO~E, 2. ROUGH - F~M~NG & PLUMBING 3. INSU~TION OCCUPANCY OR,,.. FINAL- CONSTRUCTION MUST U~Ffl~H~I ~I-~I-~E COMPLETE FOR C O WIT~T C~T~lC~TE~ou~m~s o~ T.~ co~s O~.EW [ STATE, NOT RESPONSIBLE FOR ,mDt~RW~.~R$ CER'riFICA'~ REAR ELEVATION SCALE: 1/4-" ELEVATION ~GAI F: /4" = 1'-0" 22'-0" 60'-0" 24-'-0" ,7 TYP ]~,"X~.6," CONG. PIER WZ 24 ×24' gONG FTG 3'-0" BELOW GRADE MiN 2~'X18 AC,CESS OPENING EXISTING HOUSE AN /- 1/2" LVL HEADER G65 G65 2 - 2XR DF#2 HEADER ~ 2 - 2×8 DF#2 HEADER REMOVE EXISTING DECK g REMOVE EXISTING DECK P ~ ~ ~ ~ COVERED ~ - COVERED I I ~ 1-3/4~1B L~ HEADER (AET WlOX3B SFEEL ~EA~) ~ I' , Z ' ~ EXISTING BS~ISTING~MOV~DWALL TO :~ ~. ~_~,,~,o,,~,~. ~,..~ 1ST FL PLAN SCALE: 1/4"= 1'_0" 2ND FI Pl. AN "' :" /4"1'--0" .3C, AI I , 1=~ UJ 2X6 DFC2 ~12"0C ~oon UND~RLAYMENT r~ EXISTING 1/2' 4-PLY FiR CDX SHEATH~N6 HOUSE 2X8 DFC2 RR ~16"0C ROOF: 4 - 1-3/4x18 LVL HEADER ~ ASPHALT ROOFING (ALT. WlOX~9 STEEL BEA~) ~ - ,~ ALT' EPDM ROOFING EXTERIOR WALL: ICE ~ WATER BARRIER ~ ~ ~ 5/8" T1 11 EXT $~DINO, 8"0C /2" UNDERLAYMENT INSULATION. 0 1~ FELT UNDERLAYMENT 1 4 PLY FIR CDX SHEATHING CEILING. R21 I ~ 2X~ DF~2 STUDS ~16"0C 2X8 DFC2 RR ~16"0C ~ R15 INSULANON WALLS: R15 ~ 8" COLUMN FkO0~ ~30 3/4" SUBFLOOR~ : 2X6 PT PLATE ~ TERMITE SHIELD ~ 2X8FO ~16"0C J SILL GASKET ~ ~ a W/ 24"X24" CONC FTG, .~ ~u~oo~ ~x'.., o SCALE: 5/8"= 1'-0" " 0" SCALE' 3/8 = 1' A~PIdALT ~ H I NGLB5 l/2' CDX PLYVv'OOD PROVIDE USP RT20- CONNECTOR (TYP.) 2-2" X G" TOP PLATE 2" X G" `STUD WALL -- PROVIDE U`SP R`S I 3G" CONNECTOR (TYP.) PROVIDE USP ~ I G-R 2 I" CONNECTOR 2- I 3/4"X I I 7/8,'1 LVL RIDGE ~2 -1-3 (ALT. 2" X G" `STUD KNEE WALL m--2"X6"RR IG"OC 2" X I O" LEDGER CONNECTED TO E)(I`ST~NG ROOf= 6CJ @16"0C 13 PROVIDE JU`S 2(; U`SP CONNECTOR ROOF: ASPHALT ROOFING ALT,: EPDM ROOFING DF#2 ICE & WATER BARRIER UND~RLAYMENT 1/2' 4-PLY FIR C,,B.X SHEATHING 2X8 DF#2 RR @16 0C 2-1 3/4"X I I 7/,5" LVL MEADER 5 - 2x10 HEADER LVL HEADER STEEL BEAM) EXISTING CONC. `SLAB D(I,~TING 8" CONC. WALL C C oCALE. ,3/8" EXISTING .STUD WALL 0" z" × G" RR 2" X 4" CJ COLUMI' 2" X 4" LEDGER BOLTED TO W/ I/2" CARRIAGE BOLT6 2" X G" LEDGER BOLTED TO MOUDE~ I G"OC I G"OC 0" GIRDER , ! G~E~J~_AL C_ON _STRU CTIO N NOTES 1. The mformafion on this set of ccnstnJctlon documents is to relate basic design intent and framing detell$. They are intended as a construction aid, not a substitute for generafly accepted good building practice and comp0ance wdh current New York sta~e bufld~ng codes. The general contractor is responsible for providing standard conalmction data[Is and procedures to ensure a professionally finished, structurally sound, and wedtpelpreof completed product. 2. General CentaUr to coordinate all sub contra~ora, ~cpedullng of work, and G~NERAL_ ~UNDATI(~N NOTE ~S I General contractor to review plans, elevations, and details to determine mtended heights of finished floor(s) above typical grade. 2. Att footings fo rest on undisturbed soil 3. Provide ~" expansion joint material between all concrete slabs and apuffing concrete or masonry wafls occumng in este,or or unheated interior areas. 4. Concrete on 4" sand or g~ave[ fill minimum, with 6x6 - 10110 wire mesh reinforcing. ]ntedor slabs to be placed Oh 6 mil. fltebiltzed polyethylene vapor barrier. 5. ProVide crawl ~paca ~tanfilatlon per focal code requirements. 6. General confla~or th install cop.r-tax (or bopper) sheet n~fal tam~ite shlalds batsmen all wood ~urtoces that are exposed to concret~ or masonry su~toces 7. Dampproof exterior of fouodafion wnh a bituminous ccafing as per code and soil conditions. GENERAL 1. Dimensions shall take precedent over scale drawings (do not scale drawfoge), 2, All Intedor wallfl to be covered with ½" gypsum board with motet comer ralrfforclng Tape, float, end sand (3 coats) 3 Walls common to garage and house to have a layer of 518", fire rated gypsum board at garage side with fi'-0" return on adjacent walls and ceiling, Manufactured lumber requires 2 layem of 9/9", flra rated gypsum board 4~ All bath and toilet area wells and ceilings adjonsht to v/el areas to have water resistant gypsum board, or wall tile set on wondmrbcard or equal. 1. All walls, 2x4 and 2x~, to be Stud grade or be~ter 16" o/c. All other framing mstedal to be #2 douglas fir or Petter. 2. All wood flaming in contact with concrete or malionry to be pressure treated. 3~ Provide double floor joists under all walls parallel to floor JoiSt span dirocbon ualess othem~ae specified. 4~ Provide x-bracing or salad brecklng at a maximum of 8'-0" o/c for alldimensional lumber floor jolsta. 5. Froot consttostien: %" t~ngue and groove plywood subflbor. Finished mateda[ th be applied over subfloor. Glue and screw plywood decking to flapr jofafo. 6. All window and door headem to pe minimum (2) 2x10 unless otherwise sbsc~ed. All irdedor headers to pe (2) 2x10 unless otheIwjse specified. 7. Provide f~ll solid blocking under all beadng walls 5. All beams to have adequate beadn9 at each end or as spes~ed. 9r All flUSh beam and joist tnteraecfions to have galvanized hangers 10 Typical exterior walls and roof to pe sheathed wi~ ~" extedor grade plywood or 7/16" OSB plywood, group 1, APA rated. Plywood to span over all pfates and headersr 12. Ex'tenor flashing to pe correctly installed at all connections Petween roots, walls, practices GENER~AL pLUMBti~G N_O_TES safety requirements 2. If wall plates or joists are cat during the installation of plumbing fixtures or equipment provide bracing ta tie flaming back together. GENERAL HVAC SYSTEM NOTES 1 Mechanicall subcontractor is reaponalbts for adhedng to all applicaale codas and safety requirements, 2 HVAC subcon$-actor to futiy coordinate all system data and requirements with the equipment supplier. JOINT DEBORtPTIOR ~ MAIL QUALI~Ty NAIL SPA¢INB TABLE 3.7 3. HVAC subpontmstor to provide baal system layout dra~ng and submit it to general conflactor, owner, and equipment supplier f~r final review and approval. NEW CODE CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA ~A'I~IER~IG SEVERE ~NU~ I LINE DEP'R-I 3'-0" ]~RMI~E MODERATE TO HEAVY DECAY SLIGHT TO MODERA'rE ~VINTER DESIGN TEMP~ 11 ICE SHIELD UNDER- nS PER MANUFAC~JRER'S AFf~E~'~QU(~O ~P~diF~CA~Ns / ~¥ATE CO~E' =LOAD HAZARDS GENERAL WIND PROTECTION CONNECTION NOTES Adapted from Standard for Hurdcane Resistant Residential Constmstion; ~TD 10-99 and 1995 SBC High Wfod Edition W~ed Frame Conalrocfion Fasteners and Connectors for Wood Frame Construction 1 A continuous 10ad path between footings, foundations walls, floors, studs and roof framing shall be provided. 2 Approved connectors, anchors and other fastening devices not included in the Standard Building Code, Table 2306.1 shall be installed in accordance with rnanufa(~ture~'s recommendations. 3 Metal plato~, connectors, screws, bolts, and nails exposed directly to the weather or subject to salt car;calan In costal ereas, shall be stainless steel or hot dipped galvaclzed 12 Z 2 3 3:12 5 1~ !, 4:12 4 1' ~12 3 7:12 3 ~ ~1: 3 121: 3 TABLE 3.4, 1995 S~C HiGH WiND EDITION WOOD FRAME CONSTRUCTION MANUAL RAFTER SPACING 18" OIC 1120 mph FASTEST WIND~PEED ROOF ROOF NUMla~R PITCH q.PAN (ft) OF NAILI STRUCTUFV~L WOOD PANELS FOR WIND-BO~RN_~E DEBAR_. _S PROTECTION MULTIPLE SECTION ASSEMBLY: 114" THICK BOLTS O 2' CC SHUTTER ASSEMBLY FOR PANEL SPANS: 0 < 4'-0'' WIDE 8PAN TABLE 16~$,1A 23/32" APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD (OVERLAP AROUND OPENINGS 4") USE AC GRADE W/2 COATS EXTERIOR PAINT 2 SIDES, 4 EDGES LABEL ACCORDING TO LOCATION. ASSEMBLY. ATTACHING STRUCTURAL PANEL' FASTEN TO BUILDING wi #8x3" (wi WASHERS) GALVINIZED OR STAINLESS STEEL WOOD SCREW O 16" O C. OR BETTER ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING' #10 TEE NUTS ATTACHED TO BLDG. w/#10x 1 ~2" (W/WASHERS) MACHINE BOLT @ 12" O C WHERE SCREWS ATTACH TO MASONRY OR MASONRY STUCCO, THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HALVING A MINIMUM WtTHDRAWL CAPACITY OF 490 lbs BHUTrER ASSEMBLY N.T.S. FOR PANEL SPANS: 4'4" OR WIDER SPAN SPECIFICATIONS AND ASSEMBLY IDENTICAL TO 0 < 4~-0" SPAN. NOTE ADDITIONS. 2x4 STRONG-BACKS I~ 24" CC ASSEMBLY. 1). PREASSEMBLE PLYWOOD TO 2x4'S # 10x3" (wi WASHERS) GALVINIZED OR STAINLESS STEEL WOOD SCREW @ 12" O.C ALTERNATIVE FOR OPENING PROTECTION WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/15" AND MAXIMUM PANEL SPAN OF 8'-0" SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS, PANELS SHALL SE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED TABLE 1609.1,4 '1 A ~RAFTER/RIDGE/RAFTER WrrH CT A1 ~E~RIDGE/~ERw/ocT B ,~E~P~T~STUD B ~E~P~TE PLATE/STUD C HEADE~STUD H~DE~JACK c H~DE~S~D D FLOOR TO FLOOR D  KING S3llD8 A1 ~E~RIDGE/~ERw/ocT B ,~E~P~T~STUD B ~E~P~TE PLATE/STUD C HEADE~STUD H~DE~JACK c H~DE~S~D D FLOOR TO FLOOR D , FLOOR TO FLOOR E STUD/P~TE/SILL E ~ STUD/P~TE P~T~SILL G ~POS~ ANCHORS