Loading...
HomeMy WebLinkAbout36166-ZP.O. Box 1179 54375 Main Road Southold, New York 11971 CERTIFICATE OF OCCUPANCY 3/15/2012 No: 35495 Date: 3/15/2012 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: ADDITION/ALTERATION Equestrian Avenue, Fishers Island, Sec/Block/Lot: 9.-3-11 Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this ofliced dated 2/3/2011 pursuant to which Building Permit No. 36166 dated 2/3/20 ! 1 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and additions, including pergola covered porches, to an existing one family dwelling as applied for. The certificate is issued to Peter & Katherine Baccile (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 10/5/11 36166 2/16/12 _ Tom Ravino FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUII~JING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 36166 Z Date FEBRUARY 3, 2011 Permission is hereby granted to: PETER & KATHERINE BACCILE 5 ASHTON DRIVE GREENWICH,CT 06831 for : ADDITIONS & ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING ONLY AS APPLIED FOR. THIS PERMIT REPLACES EXP. BP # 34414 at premises located at County Tax Map No. 473889 Section 009 pursuant to application dated FEBRUARY Building Inspector to ex~ire on AUGUST EQUESTRIAN AVE FISHERS ISLAND Block 0003 Lot No. 011 3, 2011 and approved by the 3, 2012. Fee $ 200.00 Authorized Signature Rev. 5/8/02 ORIGINAL FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUII~)ING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 3~4~14 Z Date FEBRUARY 5, 2009 Permission is hereby granted to: PETER E BACCILE 73 BURNING TREE RD GREENWICH,CT 06830 for : ADDITIONS & ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING ONLY AS APPLIED FOR. THIS PERMIT REPLACES BP32743. at premises located at County Tax Map No. 473889 Section 009 pursuant to application dated FEBRUARY Building Inspector to expire on AUGUST EQUESTRIAN AVE FISHERS ISLAiqD Block 0003 Lot No. 011 5, 2009 and approved by the 5, 2010. Fee $ 200.00 Authorized S~gnature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32743 g Date FEBRUARY 21, 2007 Permission is hereby granted to: PETER E BACCILE 73 BURNING TREE RD GREEAVWICH,CT 06830 for : ADDITIONS AND ALTER3~TIONS TO AN EXISTING SINGLE FAMILY DWELLING ONLY AS APPLIED FOR. at premises located at County Tax Map No. 473889 Section 009 pursuant to application dated JANUARY Building Inspector to expire on AUGUST EQUESTRIAN AVE FISHERS ISLAND Block 0003 Lot No. 011 23, 2007 and approved by the 21, 2008. Fee $ 200.00 ed Si~ Rev. 5/8/02 COPY Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUP This application must be filled in by typewriter or ink and submitted to the Building D, A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, topographic features. ~ent with the _f.~llo?_~a~ \ ke~x-an'd-~usual natural or 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electricaI installation from Board of Fire Underwriters. 4. Swom statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Old or Pre-existing Building: ~ (C~eCk one) ' LocationofProperty: '24-~>~ ~-~o~'~'i-~-~t:~x~ ~/~-~ House No. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Subdivision Permit No. ~(.~ I C-O ~ - 7_. Health Dept. Approval: Date of Permit. Block B Lot Filed Map. Lot: Applicant: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ '~0 · 12~ Final Certificate: (check one) ApplicantlSignature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (631 ) 765-9502 ro.qer, richert~.town.southo d nv us BUILDING DEPARTMENT TOWN OF SOUTI-IOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ssued To: Baccile ~,ddress: 2489 Equestrian Ave City: Fishers Island St: NY Zip: 6390 ~uilding Permit #: 36166 Section: 9 Block: 3 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE 3ontractor: DBA: Connected Systems LLC License No: SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement [~ Service Only ~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 3 ph Hot Water GFCI Recpt Main Panel NC Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment: Ceiling Fixtures [~ HID Fixtures Wall Fixtures 1381 Smoke Detectors Recessed Fixtures~[] CO Detectors Fluorescent Fixture~.~ Pumps Emergency Fixtures~ Time Clocks Exit Fixtures [~J TVSS CERTIFICATE COVERS MAIN HOUSE< POOL HOUSE< AND POOL 8-exhaust fans, 1-wirlpool bath, 7-cabinet lights, 1-9 zone gas boiler Notes: POOL HOUSE includes-8-recpticles, 15-GFCI's, 22-switches, 14-lights, 1-exhaust fan POOL EQUIPMENT-bonding, 1-control panel, 2-3/4 hp pumps, 3-2 hp pumps, 3-pool lights, 1-pool cover motor Inspector Signature: Date: Feb 16 2012 81-Cert Electrical Compliance Formxls P,O. IB~: Itt9 Fax (~.$1) IIUILOINO I)F.,~ARTMENT TOWN OF ~ou'rHot.n CERTIFICATION Building Permit No.'~ Owner: Plumber: (please print) (please print) 1 certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Sworn to before me this '~ dayof ~t'~ , 20/// Notary Public, ~b/~// County (Plumbers Signature) 07/~9/~011 13:33 FM~ $~1 788 7798 FISHERS ISLAND [~ILITY Fishers Island Utility Company P.O. Drawer E Fishers l~land, NY 06390 631 788 7251 Date 7/29/2011 TO: Gary Fish FAX#1 765 9502 From: Bob Wall FAX # 631 788 7798 SubjectBaccile Pool Mouse BP ~ 35931 Pool gates have been Corrected. Graspable hand Number of pages including this one 1 Fo~o~ (~s~) FO~ATION (2~) / PLD~G ~SULATION PER N. Y. STATE E~RGY CODE ~D~ION.~ COMMENTS "-. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. north fork. net/Southold/ ! Examined _ ^pprov.d lai Disapproved a~c Expiration ,20 PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form Trustees Contact: Mail to: Phone: APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building inspector with 3 sets of plans, accurate plot plan m scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises avallabIe for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. fi Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. lfno zoning amendments or other regulations affecting the pmpert~ have been enacted in the interim, the Building inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance ora Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein deschbed. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, ifa corporation) (Mailing ad&¢~s of ~pplicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders LicenseNo. Plumbers LicenseNo. Electricians LicenseNo. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number ~Street Hamlet County Tax Map No. 1000 Section Subdivision Block .~ Filed Map No. (Name) Lot 2. State existing use and occupancy of premises anti intended use ~nd occupancy of proposed construction: a. Exl*sting use and occupancy ca~l~[~ - ~ztl~[.~ b. Intended use and occupancy ~IV~;~J~- ,,~(~q, 3. Nature of work (check which applicable): New Building_ v/ Addition Repair ~/ Removal Demolition Other Work 4. Estimated Cost ~'001 ~ 5. I f dwelling, number of dwelling units If garage, number of cars Alteration (Description) Fee (To be paid on filing this application) I Number of dwelling units on each floor Iq/p, 6. I f business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions ofexisting structures, ifany:Front II~UIo" Rear llSLIo' Depth Height ~ 4; '"I ~' Number of Stories ~ Dimensions of same structure with alterations or additions: Front I 2.~ ~- ~-" Rear Depth g J ' Height ~ :- '"/" Number of Stories 8. Dimensions of entire new construction: Front ~'~ ;' ~" Rear ~- ~ ~ ·" Depth Height I"l ~' 6," Number of Stories t 9. Size oflot: Front } ~' J-""~Ot Rear ~59J),~'~ I Depth ~%~ t 10. DateofPurchaseJantOa0 2OO~ Same ofFormer Owner ~"~/le ~ttt/ 11. Zone or use district in which premises are situated ~, - ~' ~ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO 13. Will lot be re-graded? YES NO v/Will excess fill be removed fi~om premises? YES v/ NO 14. NamesofOwnerofpremises ?eJ~r' l~0t6C.,l~O Addresstqv-t~n~l&~£,';- 0Ol~l~oneNo. NameofArchitect }~;lhb E m'ga~euM ,t~ch~l~Aa~at'ret~s ~,:to ~. ~,g, 0~t ,nyPhoneNo /Z~2'~oqS - ~fl~ B NmeofContractor {no4 5e~c~d) Address PhoneNo. 15 a. ls ~is prope~ within 100 feet of a tidal wetl~d or a ~eshwater wetl~d? * YES ~ NO · IF ~S, SOUTHOLD TO~ TRUSTEES & D.E.C. PE~TS ~Y BE ~QUIRED. b. Is ~is prope~ wi~in 300 feet ofa tidfl wetl~d? * YES ~ NO · 1F YES, D.E.C. PE~ITS ~Y BE ~QUI~D. 16. Provide sun, ey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) COUNTY OF~~lv/og)~S: ~ ~i~ .(.(~ },~ ~ ~ [I ~ being duly sworn, deposes and says that (s)he is thc applicant (Name of individual signing contract) above named, (6~He is the 2~4(f~'11 '~q~ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to,before me thisrx ~r~ day of/~~(.~)~/~l/~_ 54_.4.)~o._.Q200'7 Nota~ Public Notaq/p ,- ub.c, State of New York No. 30-4636487 C Qualified in Nassau County ommission Expires March 30, 200..~ 12/13/2811 0S:18 0684341538 CONNEOTED SYSTEHS LL PAGE 87/10 P.O. Ik~ 11~ So~ho~d~ NY 11g?1-0959 ?elepSonc (631) Uoeme No.: BY: BUILDING DI~ARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION 3,: JOBSITE INFORMATION: (*Indicates required information) *Address: *Cross Street: *Phone No.: Permit No.: Tax,Map DisbiCt: *BRIEF DESCRIPTION OF WORK (Please Print Cleady) / o0 /O loo (Ple~ Cl~ ~ That ~ply) (~NO Rough In ~ YES / NO Temp Information (If needed} *$e~ce Size: ~ 3Phase 100 *New Service: Re-oonned Additional Information: 150 200 300 350 (~ Other Number of Meters Change of 8ervioe Overhead PAYIVIENT DUE WITH AI~ .P. UCATION 824~ue~t for Inspection Form Kinlin Rutherfurd Architects PLLC 330 West 38,h Street, Suite 1006 New York, NY 10018 222,695.2988 775582,1736 fax August 3, 2010 Pat Conklin Southold Building Department Town Hall Annex Building 54375 Route 25 P. O. Box 1179 Southold, NY 11971 (631) 765 - 1802 Dear Pat, We are requesting a six-month Permit extension for the construction project at the Baccile residence on Fishers Island, NY. The permit number is 34414. Please call our office, or send a response to confirm you have received our request. Best Regards, www.kinlinrutherfurd.com Page I of 1 To;xn llall A]mcx ,51375 Mare Road ILO. Box 1179 Soudlokl, NY 11971-0959 Tclcphonc ((;31) 765-1802 Fax (631) 765-9,502 BI !IIJ)IN(; 1)EI'AP, TMENT TOWN OF $OUTHOLD February 3rd,2011 Kinlin Rutherfurd Architects, PLLC 330 West 38th Street Suite 1006 New York, N.Y. 10018 Equestrian Avenue SCTM: 1000-9.-3-11 To Whom It May Concern: Thank you for your payment. Enclosed please find your receipt and a copy of your renewed Building Permit # 36166. This permit replaces your expired Building Permit # 34414. Please call our office at (631) 765-1802 as soon as you are ready for an inspection. THANK YOU, SOUTHOLD TOWN BUI:LDING DEPT. Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (631 ) 765-9502 BUILDING DEPARTMENT TOWN' OF' SOUTHOLD November 18, 2011 Peter Baccile 5 Ashton Drive Greenwich, CT 06830 NOTE: Equestrian Avenue, Fishers Island TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: '%'J Application for Certificate of Occupancy. (Enclosed) '""J Electrical Underwriters Certificate. ~ A fee of $50,00 __ Final Health Department Approval. Plumbers Solder Certificate. (~1 permits involving plumbing after 4/1/84) __ Trustees Certificate of Compliance. (Town Trustees#765-1892) __ Final Planning Board Approval. __ Final Fire Inspection from Fire Marshall. __ Final Landmark Preservation approval. BUILDING PERMIT: 36166-Z additions/alterations Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: Baccile House Report Date: 12/13/06 Data filename: K:\1-ACTl~l\73-BAC-1\Docs\(06)13-1\Baccile.rck Energy Code: Location: Construction Type: Heating Type: Non-Electric Glazing Area Pementage: 21% Heating Degree Days: 4910 Construction Site: Equestrian Avenue Fishers Island, NY New York State Energy Conservation Construction Code New York County, New York Detached 1 or 2 Family Owner/Agent: Peter Baccile 73 Burning Tree Road Greenwich, CT 06830 Designer/Contractor: Seth Adams Kinlin Rutherfurd Amhitects 330 West 38th Street New York, NY 10018 212.695.2988 seth @ kinlinrutherfu rd.com Ceiling 1: Flat Ceiling or Scissor Truss: Wall 1: Wood Frame, 16" o.c.: Window 1: Wood Frame:Double Pane with Low-E: Door 1: Glass: Floor 1: Ali-Wood Joist~l'russ:Over Unconditioned Space: 81 49.0 0.0 2 267 18.0 0.0 13 35 0.360 13 20 0.330 7 81 25.0 0.0 3 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance wit, h this ~ode. Builder~D-e;igner Company U~me Baccile House Page 1 of 4 REScheck Software Version 3.7.3 Inspection Checklist Date: 12/13/06 Ceilings: ~1 Ceiling 1: Flat Ceiling or Scissor Truss, R-49.0 cavity insulation Comments: Above-Grade Walls: Wall 1: Wood Frame, 16" o.c., R-18.0 cavity insulation Comments: Windows: Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.360 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No Doors: Door 1: Glass, U-factor: 0.330 Comments: Floors: Floor 1: ~l-Wood Joist/Truss:Over Unconditioned Space, R-25.0 cavity ineulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed, Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" c~earance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and ccoling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factom must be clearly marked on the building plans or specifications. Duct Insulation: I~ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. [] Return ducts in unconditioned spaces (except basements) must be insulated to R- ~l Return ducts in unconditioned spaces (except basements) must be insulated to R-2. · Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B~ Baccile House Page 2 of 4 Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w,g, (500 Pa), The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electdc meters are required for each dwelling unit, Fireplaces: [] Fireplaces must be installed with tight titting non-combustible fireplace doors. ~1 Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system, [] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Baccile House Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1,0 1.5 100~139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Typ?s Range(°F) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Baccile House Page 4 of 4 REScheck Software Version 3.7.3 Inspection Checklist Date: 12/13/06 Ceilings: I~ Ceiling 1: Flat Ceiling or Scissor Truss, R~.9.0 cavity insulation Comments: Above-Grade Walls: [] Wall 1: Wood Frame, 16" o.c., R-18.0 cavity insulation Comments: Windows: [] Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.360 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Doors: [] Door 1: Glass, U-factor: 0.330 Comments: Floors: Floor 1: Ali-Wood JoisFTmss:Over Unconditioned Space, R-25.0 cavity insulation Comments: Air Leakage: ~1 Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed, [] Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ~1 Materials and equipment must be identified so that compliance can be determined. ~1 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building must be insulated to R-8, [] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. {~ Retum ducts in unconditioned spaces (except basements) must be insulated to R- [] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. · Insulation is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Baccile House Page 2 of 4 Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g, (500 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adiusting the space temperature set point of the largest zone, Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: r~ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ~1 Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: I~1 Water heaters with vertical pipe dsers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. CI Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating end Cooling Piping Insulation: r~ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Baccile House Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Range(°F) Insulation Thickness In Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Deparlment Use Only) Baccile House Page 4 of 4 SHEETLOG iSSUED SHEET 01.18,07 A001 01.18.07 A002 01.18.07 A020 01.18.07 A030 01.18.07 A031 01.18.07 A032 01,18.07 A033 01,18.07 Al00 01.18.07 A101 01.18.07 A102 01.18,07 A103 01.18.07 A104 01.18.07 A201 01.18,07 A202 01,18,07 A203 01,18.07 A204 01.18.07 A401 01.18.07 A402 01,18.07 A501 01.18.07 A601 01.18.07 P101 01.18.07 S101 01.18.07 S102 01.18.07 S104 DESCRIPTION TITLE SHEET GENERAL NOTES SITE PLAN BASEMENT DEMOLITION PLAN FIRST FLOOR DEMOLITION PLAN SECOND FLOOR DEMOLITION PLAN THIRD FLOOR DEMOLITION PLAN BASEMENT CONSTRUCTION PLAN FIRST FLOOR CONSTRUCTION PLAN SECOND FLOOR CONSTRUCTION PLAN THIRD FLOOR CONSTRUCTION PLAN ROOF PLAN SOUTH ELEVATION EAST ELEVATION NORTH ELEVATION WEST ELEVATION WALL SECTIONS WALL SECTIONS WINDOW DOOR SCHEDULE CODE ANALYSIS RISER DIAGRAMS FIRST FLOOR FRAMING PLAN SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN BACCILE HOUSE FISHERS ISLAND NEW YORK TAX MAP: 1000 SECTION :009 BLOCK :3, LOT 11 COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TOWN ZSA SOUTNOLD TOWN P~ANNING BOARD SOUTHOLD TOWN TRUSTEES N,Y,S, DEC CERTIFICATION OF NAILING & ;ONNECTiON8 PLUMBER CERTIFICATK)N ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANC~I " SOLDER USED IN WATER SUPPLY S YS TEM CA NNOT EXCEED 2/10 OF 1% LEAD. ALL CONSTRUCTION SHALL MEET THE PF©UIREMENTS OF THE CODES OF NEW YORK STATE. 0CCUFAHCY OR USE iS U%?,WFUL WITI--t0U'! CF. ~<[IFICATE OF CC{id;:' 'J ;,;:,Y OFF/ { s.p. # ~99q%~ BUILDING DEPARTMENT AT 8AM TO 4PM FOR THE INSPECTIONS: FOUNDATION - TWO REQUIRED FOR POURED CONCRETE ~. ROUGH * FRAMING & PLUMBING ~. INSULATION ,~. FINAL -CONSTRUCTtON MUST ! SE COMPLETE FOR O O. ,&.LL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW yORK STATE. NOT RESPONSIBLE FOR IESIGN OR CONSTRUCTION ERRORS. ,, / RU.o PLUMBING ALL PLUMBING WASTE &wATER LINES NEED 't'ESTtNG BEFORE coVERWIG OOtCPL¥~t'/~TH C' FLOOD DAblAGE pREVEN'TtON sou~.o~o TOW. ~OO~' PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC 12,18.06 SCHEMATIC DESIGN 11,03.06 ~CHEMATIC DESIGN 09.15.06 REVISION ISSUE DA~ BACCILE HOUSE JAN 2 , J KINLIN RUTHERFURD ARCHITECTS, PLLC TITLE PAGE HALF SCALE PROJECT: 73 AO01 L¢-I II-I AL NU I 1, PROPER PERMITS SHALL BE OBTAINED FROM THE SOUTHOLD SEPT OF BUILDINGS FOR WORK SHOWN, 2, ALL PLUMBING WORK SHALL BE PERFORMED BY PLUMBERS LICENSED IN NY, AND SHALL CONFORM TO THE BUILDING CODE OF NEW YORK STATE 3, ALL ELECTRICAL WORK SHALL BE PERFORMED BY ELECTRICIANS LICENSED IN NY, AND SHALL CONFORM TO THE BUILDING CODE OF NEW YORK STATE, 4. CONTRACTOR SHALL OBTAIN A COMMERCIAL GENERAL LIABILITY INSURANCE POLICIE, IN THE AMOUNT OF tt2,000,OO0, AND WORKMEN'S COMP. AND EMPLOYEES' LIABILITY INSURANCE COVERING ALL EMPLOYEES OF CONTRACTORS AND SUBCONTRACTORS. S. ALL REQUIRED PERMITS SHALL BE OBTAINED, CONSTRUCTION NOTES 1. ALL WORK PERFORMED, INCLUDING MATERIALS FURNISHED, WORKMANSHIP, MEANS AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE APPLICABLE AND LATEST REQUIREMENTS OF THE BUILDING CODE OF NEW YORK STATE, ANY FIRE DEPARTMENT REGULATIONS, UTILI~ COMPANY REQUIREMENTS, AND GENERAL CONDITIONS AIA DOCUMENT #A201, (OR APPLICABLE AGREEMENT), 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE BUILDING DEPARTMENT OF SOUTHOLD, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY THE OOVERNLNG AGENCIES. 5. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY THAT ALL EXISTING CONDITIONS AGREE WITH INFORMATION SHOWN ON THE DRAWINGS. ANY CONFLICTS, OMISSIONS OR DISCREPANCIES SHALL BE BROUGHT TO THE A~ENTION OF THE DESIGNER AND OWNER FOR RESOLUTION PRIOR TO COMMENCEMENT OF ANY WORK. NO ALLOWANCES WILL SUBSEQUENTLY BE MADE ON CONTRACTOR'S BEMALF FOR ANY ADDITIONAL EXPENSES WHICH ARE INCURRED DUE TO NEGLECT OR WHICH COULD HAVE BEEN REASONABLY FORESEEN BY PRIOR INSPECTION OF EXISTING CONDITIONS, 4. PRIOR TO COMMENCING WORK, ORDERING OF MATERIALS AND SHOP FABRICATION OF ANY MATERIALS, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AS INDICATED ON THE DRAWINGS AND SHALL REPORT ANY DISCREPANCIES TO THE DESIGNER AND OWNERS REP. FOR RESOLUTION. 5. DRAWINGS INDICATE LOCATION, DIMENSIONS, REFERENCE, AND ~PICAL DETAILS FOR CONSTRUCTION. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. FOR CONDITIONS NOT ILLUSTRATED, NOTIFM DESIGNER AND OWNER'S REP, FOR CLARIFICATION AND/OR SIMILAR DETAIL, 6. CONTRACTOR TO INSPECT AT TIME OF DELIVERY ALL FIXTURES PROVIDED BY TENANT TO INSURE PROPER QUANTITY, THAT ITEMS ARE DEFECT FREE, AND MATCH iNVOICE. CONTRACTOR ~TO BE RESPONSIBLE FOR INSTALLATION, WHICH MAY INCLUDE BLOCKING, SHIMbIING, ETC. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL ITEMS SUPPLIED BY TENANT'S VENDORS AND TO VERIFY THAT ALL MATERIALS RECEIVED ARE IN ACCORDANCE WITH THE SPEC, HEREIN, 7, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS, MATERIALS AND FINISHES WITHIN THE PROPOSED CONSTRUCTION AREA AND ALL ADJOINING PROPERTY AFFECTED BY CONTRACTOR'S OPERATIONS. ~ 8. CONTRACTOR SHALL EMPLOY ADEQUATE NUMBER OF SKILLED WORKERS WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFfS AND WHO ARE COMPLETELY FAMiLiAR WITH THE SPECIFIED REQUIREMENTS AND METHODS NEEDEDFOR PROPER PERFORMANCE OF THE WORK, ALL WORK SHALL BE PERFORMED BY DULY LICENSED PROFESSIONALS AND AS REQUIRED BY STATE AND LOCAL GOVERNMENTS FOR EACH APPLICABLE TRADE, (PLUMBING, ELECTRICAL, ETD), WHO SHALL ARRANGE FOR AND OBTAIN REQUIRED INSPECTIONS AND SIGN OFFS. 9. THESE DRAWINGS ARE DIVIDED INTO SECTIONS FOR CONVENIENCE ONLY. CONTRACTOR, SUBCONTRACTORS, VENDORS AND MATERLAL SUPPLIERS SHALL REFER TO ALL RELEVANT SECTIONS IN BIDDING AND PERFORMING THEIR WORK AND SHALL BE RESPONSIBLE FOR ALL ASPECTS OF THEIR WORK REGARDLESS OF WHERE THE INFORMATION OCCURS ON THE DRAWINOS. I0. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WORK OF ALL TRADES AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK WITH THE WORK OF OTHERS, AND SHALL VERIFY THAT ANY WORK RELATING TO THEM THAT MUST BE PROVIDED BY OTHERS, HAS BEEN COMPLETED AND IS ADEQUATE PRIOR TO COMMENCING iTHEIR WORK. 11 CONTRACTOR SHALL PROVIDE STRUCTURAL BACKING/BLOCKING FOR ALL WALL MOUNTED FIXTURES, FINISHES AND EQUIPMENT, AND FOR ALL HANGING FIXTURES, BLINDS, ETC. 12. CONTRACTOR SHALL INSTALL ALL MATERIALS AND EQUIPMENT AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND/OR RECOMMENDATIONS. 15. CONTRACTOR SHALL AT ALL TIMES DURING THE COURSE OF THE CONTRACT KEEP THE ADJOIN[NO PREMISES, INCLUDING STRE~S AND OTHER AREAS ASSIGNED TO, OR USED BY THE CONTRACTOR, FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND RUBBISH CAUSED BY CONTRACTOR'S EMPLOYEES, SUBCONTRACTORS OR THEIR WORK. 1'¢. CONTRACTOR SHALL BE RESPONSIBLE TO RECEIVE AND SAFELY STORE THE OWNERS SUPPLIED iTEMS AND DISPOSE OF ANY RESULTING TRASH, 15. SHOP DRAWINGS FOR ALL TRADES PRIOR TO CONTRACTOR SHALL PROVIDE INSTALLATION, AND SAMPLES OF ALL MATERIAL AND COLOR/ FINISHES FOR DESIGNER'S AND OWNER'S APPROVAL. CONTRACTOR SHALL PROVIDE TIMELY AND COMPLETE DATA ON AMY DEVIATION/ SUBSTITUTION FROM CONTRACT DOCUMENTS. 16. CONTRACTOR TO VERIFY ALL FIXTURE COUNTS, AS APPLICABLE TO THEIR CONTRACT, WITH OWNER 17, CONTRACTOR SHALL BE RESPONSIBLE FOR CLOSEOUT, PRIOR TO FINAL PAYMENT, INCORPORATING ALL STANDARD GUARANTIES AND WARRANTIES AND ORIGINALS OF ALL APPLICABLE CERTIFICATES OF TESTING AND INSPECTION. COORDINATE WITH OWNER, 18. CONTRACTOR TO PROVIDE COPIES OF AS BUILT INFORMATION, OPERATION AND MAINTENANCE MANUALS, INCLUDING ALL PRODUCT GUARANTIES AND WARRANTIES TO THE CLIENT. 19. CONTRACTOR TO PROVIDE A TELEPHONE AND FAX MACHINE ON SITE FROM THE FIRST DAY OF CONSTRUCTION UNTIL COMPLETION, A JOB FORMAN OR PERSON IN CHARGE MUST BE ASSIDNED, AND THE APPROPRIATE NUMBERS GIVEN TO BRUCE KINLIN ARCHITECTS, 20. SHOP DRAWINGS ARE REQUIRED AND MUST BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOIR TO ORDERING OR MANUFACTURING ANY PORTION OF THE PROJECT WHERE SUCH DRAWINGS ARE NECESSARY, THESE DRAWINGS ARE NECESSARY FOR ANY COMPONENT OF THE PROJECT BUILT OFF SITE AND DEDLIVERED TO THE SITE AND INCLUDES BUT IS NOT LIMITED TO CABINETS, WINDOWS, DOORS, ENGINEERED TRUSS FLODRINO OR WALL SYSTEMS, NVAC DUCTWORK EDT, PINI M NUI h_bi 1. ENSURE THAT SURFACE TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED COMMENCEMENT DF WORK SHALL INDICATE INBTALLER'S ACCEPTANCE OF SUBSTRATE. 2 REPAIR AND PREPARE EXISTING SURFACES SCHEDULED TO REMAIN AS NECESSARY FOR APPLICATION FOR APPLICATION OF NEW FINISHES, 3 CONTRACTOR TO INSURE DELIVERY AND INSTALLATION OF CASEWORK AND FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION WORK. ,~ ALL CODE-REQUIRED LABELS SUCH AS "UL" FACTORY MUTdAL OR ANY EQUIPMENT IDENTIFICATION PERFORMANCE RATING, NAME OR NOMENCLATURE PLATES SHALL REMAIN READABLE AND NOT PAINTED, 5. THE CONTRACTOR SHALL PATCHI SURFACES TO MATCH ADJACENT IN A MANNER SUITABLE TO RECEIVE FINISHES. 6. COORDINATE WITH OWNER'S BESINATED REPRESENTATIVE FOR DELIVERY AND PLACEMENT OF ALL FURNITURE AND WALL-HUNG EQUIPMENT. 7. REFER TO FINISH SCHEDULE FOR SPECIFIED FINISHES. 8. REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS REQUIRMENTS. PLUMBING NOTES 1. DO NOT SCALE FROM RISER DIAGRAMS, 2, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE BUILDING CODE OF THE TOWN OF SOUTBOLD AND RS 16. 5 OBTAIN AND PAY FOR ALL PERMITS, CERTIFICATES, ETC, REQUIRED. ¢¢. VERIFY FIELD CONDITIONS AND LOCAL CODES BEFORE SUBMITTING BID. 5. DELIVER CERTIFICATES OF FIINAL INSPECTION TO OWNER BEFORE APPLYING FOR FINAL PAYMENT. 8. PITCH HORIZONTAL DRAINAGE PIPING 3' DIAMETER AND LESS 1/4" PER FOOT MINIMUM; OVER 3" DIA. PITCH 1/8" PER FOOT MINIMUM. 7. SPACING BETWEEN CLEAN OUTS SHALL NOT EXCEED 50' 0". 8. GUARANTEE ALL WORK FOR A PERIOD OF 1 (ONE) YEAR FROM DATE OF FINAL ACCEPTANCE. 9. ALL HOT AND COLD WATER ILINES TO HAVE SHUTOFF VALVES. D.O.B. INSPECTIONS 1. AS REQUIRED BY THE LOCAL TOWN DEPARTMENT OF BUILDINGS CONTRACTOR SHALL NOTIFY DEPARTMENT OF BUILDING FOR REQUIRED INSPECTIONS PRIOR TO PROCEEDING WITH WORK, ALL INSPECTIONS DONE BV BUILDING DEPARTMENT OFFICIALS, 2. ADDITIONAL INSPECTIONS MAY BE REQUIRED AS DIRECTED BY THE DEPARTMENT OF BUILDING. SEE INSPECTION CARD. B. CONTRACTOR SHALL INCLUDE ,3% ~- OF CONTRACT SUM FOR CONTROLLED INSPECTIONS IF PERFORMED BY AN ARCHITECT/ENOINEER 4. CONTRACTOR WILL BE RESPONSIBLE FOR ANY WORK DONE WITHOUT PROPER APPROVALS FROM THE BUILDING DEPARTMENT. LEGEND EXIST, WALLS 84 CONDITrONS EXIST. WALLS TO BE REMOVED NEW INTERIOR WALL (SEE PARTITION TYPE 84 DETAILS) NEW EXTERIOR WALL (SEE PARTITION ~PE ~ DETAILS) SMOKE DIETECTO R DOOR TAG WINDOW TAG REVISION CLOUD PARTITION TYPE E = EXISTING N - NEW R = RELOCATED E = EXISTING N = NEW DETAIL REFE[RENCE SECTION REFERENCE ELEVATION T;AO 04/A-20~ 03 EXTERIOR ELEVATION INTERIOR ELEVATIONS PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC 12.18.06 SCHEMATIC DESIGN 11.03.06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC GENERAL NOTES HALF SCALE PROJECT: 73 AO02 / // // /// / / / / / / // / / / / / / / / / / / / / I,MITE CF IIDAL N 35'48'00" 25.00' COASTAL EROSION HAZARD \\ LINE AS SHOWN ON COASTAL '\ EROSION HAZARD MAP TOWN \ OF SOUTHOLD, SUFFOLk ....... COUNFY, NEW YORK SHEET 49 FI OF 49F · E, ITU C i'B~N~HMARK I , HUB AND TAOK ELEVATION =57.80 / / / / '~ L / T ,fL ,(' (T,B,D,) SELF CLOSING AND SELF LATCHING POOL E CLOSURE GATES ~ REQUIRED (TYp) / / / / / / / / / / / / / / / / CONC, OSURE CONC, STEPS NEW GARAGE/ X QUALITY CONTROL CERTIFICATION FILE I \ \ \ \ \ \ X \ \ \ \ CFLOATING DOCK SECTION L I ,TTL E 'Pes? GRANITE POST 3"X4= POLE THIS ORIBINAL SURVEY DRAWING WAS PREPARED BY CME ASSOCIATES ENGINEERING, LAND SURVEYING & ARCHITECTURE, PLLC AND REVISED BY KINLIN RUTHERFURB ARCHITECTS, PLLC WITH LANDSCAPE DESIGN BY INVITING ENVIRONMENTS. EXISTING RIGHT OF WAY DRIVEWAY N 1459.58 W 5491.90 .~/' / LOCATION MAP SCALE 1"=400' MAP REFERENCES PROPOSED INGROUND SWIN[~ING POOL NOTES 3) THE POOL MECHAIh<AL EUIIIPMEIIT WILl BE FI,\CFD OH A TnlqC"E E :'AS REQUIRED B) SETBAsl, T,3 hl:,[I DIE~URBFIICE EUE'FEP hO' PROPO PERMIT DOCUMENTS PARTIAL PERMIT DOC SCHEMATIC DESIGN SCHEMATIC DESIGN REVIBION ISSUE BACCILE HOUSE FISHERS ISLAND, NEW YORK KINLIN RUTHERFURD ARCHITECTS, PLLC SITE PLAN HALF SCALE PROJECT: 73 A020 BASEMENT I I REMO~ PARTITIONS AND DOORS IN THEIR ENWRETY, AS SHOWN, MODIFY EXISTING OPENING TO ACCDMODATE NEW DOOM CUT NEW OPENING TO ACCOMODATE NEW DOOR, EXIS~NG WALLS TO BE REMOVED IN THErR ENTIRETY, REMOVE EXIS~NG TOILET AND FINrSHES W II L REMOVE EXISTING WALL TO ADSOMODATE NEW DOOR OPENING j EXISTING DOORS AND STEPS TO BE RE~OV~D IN THEIR ENTIRETY ~ I~1 I--,;"'--1 Ill J--------Ill ~--------.-J l J-- EXISTING DOORS AND FRAMES '--~. ', ,'~ III I 1 BASIEMENT DEMOLITION PLAN PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC 12.18.06 SCHEMATIC DESIGN :L1.03,06 SCHEMATIC DESIGN 09.1B,06 BACCILE HOUSE BASEMENT GROSS F.A, - 3,930.20 SF KINLIN RUTHERFURD ARCHITECTS, PLLC BASEMENT DEMOLITION PLAN HALF SCALE PROJECT: 73 A030 TERRACE DECK _/ LIBRARY OFFICE CL, BATH, / ENTRY LIVING ROOM FOYER EXISllND CABINET , TD BE ENLARGED FOR WINE COOLER- /\ REVERSE DOOR SWING, DINING ROOM CL. PANTR SITTING ROOM III gJ ' INSTALL NEW WALL AT FIREPLACE OPENING, U HII!) II --IIII II -IIII ~ --4 JLi I~1 I IFI II IIII F'q':RIF~'ER"II- ......... -1 I I II I J'b~l~ ~-'o-"-- ', r---~ u,, PORCH EXISTING WALL AND DOOR TO BE REMOVED IN ~NEIR ENTIRETY, EXISTING STAIR TO BE REMOVED IN rTS EN~RE~Y ~ll MUD Ik OOM II N REMOVE EXISTING WALl AND RAILING REPLACE EXISTING RANGE REPLACE EXISTING RANGE, Ol FIRST FLOOR DEMOLITION PLAN PERMIT DOCUMENTS 0i.18.07 PARTIAL PERMIT DOC :L2,J.8.06 SCHEMATIC DESIGN 1 J.,03,06 SCHEMATIC DESIGN 09.J.5,06 BACCILE HOUSE J. ST FLOOR GROSS F.A. = 3,774.00 SF KINLIN RUTHERFURD ARCHITECTS, PLLC FIRST FLOOR DEMOLITION PLAN HALF SCALE PROJECT: 73 A031 U B MASTER BEDROOM CL, BEDROOM U CL, J CL. BEDROOM REMOVE EXISI]NG FINISHES REPEACE ROILET. EXlS]INO RA~TUB AND LAVATORY TO REMAIN. DRESSING ROOM REMOVE WALLS, DOORS AND CASINGS AS SHOWN RELOCATE TOILET, BATHTUB AND LAVATORY REMDVE EXISTING FIXTURES, CABINETRY AND FINISHES, MASTER~ BATH / HALLWAY EXPAND SHDWER STALL REMOVE EXISTING FIXTURES, AND F1NISHES REPLACE TOILET NELOCATE LAVATORY. BATH 2x X BEDROOM CL. CL, lu BATH II 5 II MAID'S ROOM B BEDROOM CUT NEW OPENING TO ACCOMMODATE NEW DOOR, REMOVE EXIS~NO DOORS AND WALLS A~ SHOWN _ BATH 4 BALUSTNADE TO BE RESTORED. SAVE SINK REPLACE TOIEET EXISTING BATH~JB TO REMAIN. I MAID'S ROOM MAID'S ROOM LAUNDRY ROOM MAID'S ROOM II o 1 SECOND FLOOR DEMOLITION PLAN 3/161' = p-0" PREPARE FOR ROOF EXTENOION PERMIT DOCUMENTS 01.].8.07 PARTIAL PERMIT DOC :1.2.18.06 SCHEMATIC DESIGN :L~L,03,06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE 2ND FLOOR GROSS F.A. = 3,640.00 SF KINLIN RUTHERFURD ARCHITECTS, PLLC SECOND FLOOR DEMOLITION PLAN HALF SCALE A032 PROJECT: 73 WALK-IN CLOSET BEDROOM , CUT NEW OIPENINS -- TO ACCOMMODATE NEWrDOOR CL. BEDROOM BEDROOM BEDROOM CL. II " STORAGE BEDROOM STORAGE SAVE ALL EX[S~NG STORAGE CABINETS AND RE USE OR MOVE REBOVE EXIS]ING WALLS, DOOR, WINDOW AND CASINGS, DOOR TO RE RETAINED AND RE-USED, BEDROOM 01 THIRD FLO)OR DEMOLITION PLAN MECHANIIAL INSTALL I WALLS EXGEPT ON WALL Wi~ EXPOSED BNICK INSTAL NEW AND LOCKrNG BAES AREA INSTALL NEW LAVATORY, TOILE% NEW BEAD BOARD ON WALLS, STONE TILE FLOOR AND NEW LIGHT FIXTURE INSTALL NEW LAVATORY, TOILET, NEW TILE ON 9\ WALLS, STONE TILE FLOOR ~ AND NEW LIGHT FIXDJRE \, ~ANELS / BE-LOCATE NVAC DUCT ELECTRIC ROOM INSTALL NEW MIRROR ON WALL, REFER SHEET A506, iNSTALL NEW WALLS AND DOORS AS SHOWN 04 02 GYM 16' g" x 16'-5" 04 02 NOTES: 1, ALL EX~RIOR WAILLS TO RECEIVE NEW WOOD SHINGLES, 2, ALL EXISTING WALLB AND CEILINGS TO BE PATCHED, SKIWMED AND CLEANED, AS REQUIRED, D, ALL SURFACES TO RE REPAINED AND REFINISHED, AR REDUrRED, A. ADD NEW STORM PROTECflwN TO ALL WINDOWS, MIS WILl INCLUDE A NEW SNUT~R SYSTEM ON ALL WINDOWS AT THE COVERED PORCH. INSTALL NEW PULL DOWN SYSTEM, INSTALL WALL AT EXISTING OPENING. INSTALL NEW SINK, CABINETRY, SHELVING, UNDERCOUNTER ICEMAK~ER AND REFRIGERATOR, DEER TAPS, AND LIGHT FIXTURES, INSTALL DRINK LEDGE BiLLiARD ROOM 19' 6" x 15'-4" INSTALL NEW WALL AT EXISTING WINDOW OPENrNG TO HEIGHT OF CRAWLSPACE FLOOR, STORAGE INSTALL/REPAIR PLASTER WALLS IN STORAGE AREA rNSTALL NEW WALL AT EXISTING DOOR OPENING WIBTALL NEW PLASTER WALLS INSTALL NEW BENCH SEA~NG 0 1 BASEMENT CONSTRUCTION PLAN INSTALL NEW WALL AND DOOR AT EXIS,qNG WINDOW OPENING PERMIT DOCUMENTS 0~.,'18.07 PARTIAL PERMIT DOC 12.:L8.06 SCHEMATIC DESIGN 3-1.03.06 SCHEMATIC DESIGN 09.:L5.06 REVISION I,~SUE DATE BACCILE HOUSE BASEMENT GROSS F,A, = 3,930.20 SF KINLIN RUTHERFURD ARCHITECTS, PLLC BASEMENT CONSTRUCTION PLAN HALF SCALE AiO0 PROJECT: 73 - I' ALL PAJNTbD WOODWORK TO BE SANDED ANB PREPAREB FOR FINISH PAINT AND RE-PAINTED EX STING WIDOWS TO BE RE-CONDITIONED II 18'71'l't X 1:lG'ZI'' II ',1 II OFFI CE ~ 14'-1 X 9'-8" J I 50,710,, BATH ENTRY LIVIN~ IROOM 29-51~~ 41-o' iI ,I II VESTIBULE 14'14" x 10'-5" / CL. 29'-0" DINING ROOM PANTRY NOES: 1 AM EXTERIOR WALLS TO RECEIVE NEW WOOD SHINGLES, L CL. SITTING ROOM INSTALL NEW COPPER ROOF OVER DINING ROOM. ALL PAINTED WOODWORK TO BE SANDED AND PREPARED FOB FINISH PAINT AND RE-FAINTED AM WINDOWS TO BE RERAINTED REPAIR CURVED BUNDS, AS NECESSARY, STAIRS TO BE REFINISHED, AS REQUIRED. OE RELOCAEO NEW DISHWASHER O8 WIW] REFRIGERATO: ,~1 ,T, CHEN 25 F6 x II /__~_~ 4" DIA STEEL COLUMN DW 53'-5" INSTALL CABINETRY, CUBBIES AND HOOKS ABOVE AS INSTALL NEW STONE COUNTERTOP, INSTALL NEW CASINGS, BASEBOARDS AND TRIM, INSTALL NEW WASHER AND DRYER, 21 '-6" ROOM ' ag2 7' 0" x 8'-9" PORCH Jl w 1 FIRST FLOOR CONSTRUCTION PLAN PERMIT DOCUMENTS PARTIAL PERMIT DOC SCHEMATIC DESIGN SCHEMATIC DESIGN BACCILE HOUSE 4" DIA, STEEL COLUMN INSTALL NEW DECK FOUNDA~ON, DECK, RAILING AND PERGOLA RELOCATED NEW DISHWASHER ;INN, INSTALL NEW STONE COUNTERTOP AND qLE BACKSPLABHES, INSTALL NEW CASINOS, BASEBOARDS AND TRIM 4" DIA STEEL COLUMN INSTALL NEW DISHWASHER RELOCATED NEW RANGE. KINLIN RUTHERFURD ARCHITECTS, PL NEW EXTENDED ROOF FIRST FLOOR CONSTRUCTION PLAN PROJECT: 73 23'-11" 30'ff9" 19'-7" MASTER BEDROOM 19'-1 x 16'-11" DRESSING ROOM BEDROOM 1~-'-9'' x 16'-&" BEDROOW l¢'-f'x 13'-11" CL HALLWAY B",~,T __t MASTER BEDROOM 14' 1" x 16'-(' 2 BATH INS RELOCATED STONE VANITY AND 9'-10" _L NEW WALLS, CABINETRY AND DDON AS SHOWN, NEW TOILET AND LAVATORY ISTALL NEW TILE ON WALLS INSTALL NEW LAVATORY, )UN%RTOP, LIGHT FIX~RES, CESSED MEDICINE CABINETS, 21 '-7" ;XPANDED SHOWER STALL WI~H TILE WALLS, ( SHELF, FRAMELESS GLASS ENCLOSURE AND DOOR. INSTALL NEW WNE ON RELOCA~D NEW LAVATORY, INSTALL NEW LAVATORY, SRONE COUN RTOP, AND LIGHT FIGURES, VANI~ AND RECESSED MEDICINE CA INETR, 12'-0" 17'-2" INSTALL CL. NEW BATHTUB REPLACED TDILET, BEDROOM 19'-1" x 16'-10" LC MAID'S ROOM 10'-1" x 9'-7" INSTALL NEW WALLS~ AS SHOWN, [EW TLLE ON WALLS BATH 4 (NEW)" 10'- 0" x 13'-1" ' ROOM / ' 9'-7" REPLACED WASHING MACHINE AND OAS DRYER 27'-5" £XIS~ND BALUSTADE TO BE RE-BUILT/RESTORED. INSTALL NEW DOOR AND S~PS, AS SHOWN, - INSTALL (2) NEW LAVATORY WITH STONE COUN~RTOP, VANIW AND RECESSED MEDICINE CABINETS AND UGHT FIXTURES -- WISIALL NEW BATHRUB AND TOILET, INSTALL NEW SHOWER STALL WITH TILE WALLS, FRAMELESS GLASS ENCLOSURE AND DOOR, I NE~ TOILE~ B. ATH MAID'S ROOM 11'-11" x 9'-5" LAUNDRY ROOM MAID'S ROOM 9'-9" x 9' 7" 10'-7" 'I* 01 SECOND FLOOR CONSTRUCTION PLAN PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC 12,18.06 SCHEMATIC DESIGN 11,03,06 SCHEMATIC DESIGN 09.t5.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC SECOND FLOOR CONSTRUCTION PLAN HALF SCALE A1022 PROJECT: 73 BEDROOM 18'-7" K 16'-5" WALK IN CLOSET BEnDRO@M 17'-6" x 24'-11" CL. BATH BEDROOM 9'-10" 15'-7" k STORAOE RELOCATED NEW SHOWER W1TH WEE WALLS AND FRAMELESS GLASS ENCLOSURE AND DOOR. - INSTALL NEW BA~TUB AND PEDESTAL SINK, INSTALL NEW RECESSPD'MEDICINE CABINETS AND LIGHT FIXTURES,' RELOCATED NEW TOILE~. BATH STORAGE INSTALL NEW WALL AS SHOWN -- INSTALL NEW PLUMBING LINES INSTALL NEW TOILET, BATHTUB AND TWO LAVATONIES WITH STONE COUNTEfiTOP, VANITY AND REDESSED MEDICINE CABINETS, AND NEW LIGHT FIXTURES INSTALL NEW WALLS AND STEP, AS SHOWN INSTALL NEW TILES ON WALLS NEW CLOSET NTH HANGING BAR AND SHELF ABOVE. RELOCATED NEW PEDESTAL SINKS (2), INSTALL NEBN WALLS AND CABINETRY, AS SNOWN~ INSTALL NEW TILE ON WALLS, SAM[ ALL EXISllNG STORAGE CABINETS AND RE USE OR ~OVE INSTALL NEW WALLS AS SHOWN BEDROOM 19'-§" x 15'~1" 0 1 THIRD FLOOR (CONSTRUCTION PLAN REVISED PERMIT DOCUMENTS 02.13.07 PERMIT DOCUMENTS 12.18.06 SCHEMATIC DESIGN ~-1.03.06 SCHEMATIC DESIGN 09.'15.06 REVISION ISSUE DATE BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC THIRD FLOOR CONSTRUCTION PLAN HALF SCALE A103 PROJECT: 73 RE-CREATE PERGOLA INSTALI NEW PIECES TO MATCH E~IS~NG PIECES. TI, I NEON EXTENDED ROOF. -- IlL I!ll REVISED PERMIT DOCUMENTS 02.13,07 PERMIT DOCUMENTS 12.±8.06 SCHEMATIC DESIGN 11.03.06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC ROOF PLAN HALF SCALE Al04 PROJECT: 73 - _', _1,,'..,, T IIII SECOND FLOOR (LEVEL 2) ~ ELEV 17' 11 1/~" SECOND FLOOR (LEVEL 1) ~ ELEV, 16' · 1/4" FIRST FLOOR ELEV+ 5' 6" 1 SOUTH ELEVATION PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC ±2,~_8.06 SCHEMATIC DESIGN 11,03.06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC SOUTH ELEVATION HALF SCALE PROJECT: 73 A201 SECOND FLOOR (LEVEL FIRST FLOOR (LEVEL 2) ¢ ELEV 8' 7" FIRST FLOOR EAST ELEVATION REVISED PERMIT DOCUMENTS 02 J.3,07 PERMIT DOCUMENTS 3.2.18.06 SCHEMATIC DESIGN ~.1.03.06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC EAST ELEVATION HALF SCALE PROJECT: 73 A202 A/]]C {bEVEL 2) A]T[C (U-VEL 1) SECOND FLOOR i ELFV 17' 11 1/4" SECOND FLOOR (LEVt'L ELEV. 16' · 1/4~ FLOOR (LEVEL FIRST FLOOR ELEV. 5'-6' REVISED PERMIT DOCUMENTS 02.13.07 PERMIT DOCUMENTS 12.18,06 SCHEMATIC DESIGN 11.03.06 SCHEMATIC DESIGN 09,15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC 0'~ NORTH ELEVATION NORTH ELEVATION HALF SCALE PROJECT: 73 A203 (LEVEL FIRST FLOOR ELFV. 5' 6* iI 1 LONGITUDINAL SECTION REVISED PERMIT DOCUMENTS 02,13.07 PERMIT DOCUMENTS 12.:].8,06 SCHEMATIC DESIGN 11.03,06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC LONGITUDINAL SECTION HALF SCALE PROJECT: 73 A211 £LEV. 27'--4 A~C (LEVEL 1) FIRST FLOOR r~ 4 WEST ELEVATION 2/16' ~ l'~' PERMIT DOCUMENTS 01,18,07 PARTIAL PERMIT DOC 12,18.06 SCHEMATIC DESIGN 11.03.06 SCHEMATIC DESIGN 09.t5.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC WEST ELEVATION HALF SCALE PROJECT: 73 A204 EXISTING L EXISTING 2 X 12 FLOOR JOISTS DOUBLE TOP PLATE~ (5) 1.5 X 9,25 LVL BEAM SIMPSON CAP k0C7-4 4" LALLY COLUMN 2x6 KING STUD 2x6 COMMON STUD- , / EXISTING '11 II ASPHALT SHINGLES - ASPHALT ROOFING PAPER ON SHEATHING ~ PLYWOOD SHEATHING ,-- GUTTER ,,'/ CONTINUOUS CEDAR FACIA '~,' -GALVANIZED FLASH NG VENTED SOFIT CONTINUOUS CEDAR TRIM CEDAR SIDING --2X12 BUILDING PAPER ON NATURAL FINISH CEDAR PAINTE,D, CEBAR BALUSTERS O.C. (4 MAX. INSIDE DIM.) SHEATHIING HAND RAIL ~ ~2 / OPEN DECKING '--12 X 12 DECK JOIST x ,__CEDAR SIDING ~ -- BUILDING PAPER ON 2 SHEATHhNG ,, x~ MAINTAIN 1" GAP BELOW SIDING ~- 2 X12 JOIST HANGAR ,, --2 X12 RIM JOIST , '--2 X10 PRESSURE TREATED SOLE " PLATE ----CONCRETE ANDHOR BOLT HIGN DENSITY FIBERGLASS BATT '1 , I RE CONSTRL 0 1 KITCHEN EXTENTION AND DECK PERMIT DOCUMENTS O:L.Ls,C7 PARTIAL PERMIT DOC 12.18,06 SCHEMATIC DESIGN 1:[.03.06 SCHEMATIC DESIGN 09.:[5.06 BACCILE HOUSE KINLIN RUTH£RFURD ARCHITECTS, PLLC WALL SECTION HALF SCALE PROJECT: 73 A401 L ASPHALT SHINGLES ASPHALT ROOFING PAPER ON SHEATHING ~ PLYWOOD SHEATHING GUTTER CONTINUOUS CEDAR FACIA GALVANIZED FLASHING · ,, ,, '~ CONTINUOUS CEDAR TRIM '~ ~, CEDAR SIDING ~ --' 2 X 12 LINTEL " BUILDING PAPER ON ~ SHEATHING XIS¥1NG' II; I II , '~' (CEDAR SIDING · BUILDING PAPER ON " '. ' ',';2 X 12 RiM JOIST ' 'kVlAINTAIN 1" GAP BELOW SIDING · ' STONE VENEER 2 X 10 PRESSURE PLATE CONCRETE ANCHOR 8" CMU TREATED SOLE BOLT I I I I 01 KITCHEN EXTENTION I I PERMIT DOCUMENTS Ol.iS.07 PARTIAL PERMIT DOC i2.18.06 SCHEMATIC DESIGN 11,03,00 SCHEMATIC DESIGN 09,15.06 RE'SION ISSUE DATE 8ACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC WALL SECTION HALF SCALE PROJECT: 73 A402 WINDOW SCHEDULE (ALL ROUGH OPEINING DIMENSIONS MUST BE VERIFIED IN THE FIELD) Rough Opening Size Jamb Casing Divided Exterior REMARKS Window# Room # Rm Name Type Manufact. Product # Description Width Height Depth Type light Screen Hardware Cladding 101 101 Kitchen A Marvin CUDH 31020 Double Hung 36.375" 48.875 * 6" V.I.F. SDL Y White Whrte Crad Zone 3 Impact Resistant 102 101 Kitchen B Marvin CnDH 3026 Double Hung 36.375" 60,875 6" VJ.F. SDL Y White White Clad Zone 3 Impact Resistant 301 301 Landmg C Marvin CUSTOM TO MATCH EXISTING Double Hung V.I.F. VJ.F. 6" V.I.F. SDL Y White White Clad Zone 3 impact Resistant 302 301 Landing C Marvrn CUSTOM TO MATCH EXISTING Double Hung V.I.F. V.[.F. 6" Vd.F. SDL Y WMte Whrte Clad Zone 3 Impact Resrstant 303 301 Landing C Marvin CUSTOM TO MATCH EXrSTING Double Hung V. LF. V.[.F. 6" V.I.F. SDL Y Wh[ta White Clad Zone 3 ~mpact Resistant DOOR SCHEDULE t Jamb Rough Opening Dim. Hardware Remarks Door ID # Room ID# Room Name Type Manufact, Product # Description Handing Screen Grills Depth Casing Width Height Set 101 101 Kitchen I D Marvin CIFD 3(070 X L Clad InswTng French Door V,I,F, 38.4375 86.5 Zone 3 Impact Resistant 102 102 Mud Room C Marvin CJFD 3(070 X L Clad Insw[ng French Door V.hF. 38,4375 66,5 Replacement Door NOTES: 1, DOOR TRIM TO BE iNSTALLED BY MANUFACTURER UNLESS OTHERWISE NOTED. 2. VERIFY ROUGH OPENING DIMENSIONS WITH DIMENSIONS ON CONSTRUCTION PiLAN. 5. DOORS WHICH 00 iNTO EXISTING FRAMINO; VERIFY DIMENSIONS IN FIELD AND CONSULTANT W/ARCHITECT IF ANY DISCREPANCIES ~-. DOORS IN EXISTING WALLS; PATCH WALL AS REQUIRED TO RECiEVE NEW TRIIM. PERMIT DOCUMENTS 01.18,07 PARTIAL PERMIT DOC 12.18.06 SCHEMATIC DESIGN 1t,03,06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE {10 2};, KINLIN RUTHERFURD ARCHITECTS, PLLC WINDOW SCHEDULE DOOR SCHEDULE HALF SCALE A501 PROJECT: 73 BACILLE HOUSE - FISHERS TABLE R301,2(1) CLIMACTIC AND GEOGRAPHIC DESIGN CRITERIA Ground Wind Speed Seismic SUBJECT TO DAMAGE FROM Snow (MPH) Design Frost Line to Heavy I Winter Load Category Depth Weathering Termite Decay esfgn Tern Moderate Slight to 45 20 B 38" Severe Moderate 116 Iceshield Underlay Flood Required? Hazard Yes N/A 08 DESIGN CRITERIA CODE ANALYSIS: USE/OCUPANCY: R-GO (14 BEDROOM DETACHED SINGLE FAMILY) HEIGHT AT RIDGE: 45'1 1/2" FIRE AREA: 15,965.2 SQ. FI, (TOTAL, EXISTING + ADDITION) TYPE OF CONSTRUCTION TYPE 5 DESIGN CRITERIA- PRESCRIPTIVE FRAMING MATERIAL DOUGLAS FIR #2 THE NEW ROOF AND THE NEW ADDITION ARE DESIGNED TO MEET ALL OF THE REQUIREMENTS OF THE BUILBINO CODE OF THE STATE OF NEW YORK. THE WOOD FRAMED STRUCTURE HAS BEEN DESIGNED TO THE SPECIFICATIONS SET FORTH IN THE WOOD FRAME CONSTRUCTION MANUAL (WFCM) HiGH WIND ADBITION FOR 120 MPH WIND SPEED CATEGORY EVERY NEWV SLEEPING ROOM IS TO HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE ANB RESCUE OPENING WITH A SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FLOOR WITH A MINIMUM NET CLEAR OPENING OF 5,7 SQUARE FEET (MINIMUM 20" WIDTH AND 24" REIGNT), SMOKE ALARMS MUST BE PROVIDED AS PER NFPA 72 - SECTION R 517 1. LATERAL FRAMING AND SHEAR CONNECTIONS: Ali lateral framing end shear connections for the roof assembly are to be made in accordance with table 5.1 of the W.F.CM, This nailing scheduJe shown below fs that schedule with all values included. UPLIET CONNECTIONS: All roof to wail, wall to walt, and wall to foundoban connections meet or exceed the requirements from table 5,56 or 5,5 in the W,F,C.M, 1, Connectors specificoDons exceed the uplift load, Lateral load, end shear ladd requirements specified in table 2. Any connecBan, roof to wall, wall to wall, end wall to foundation, that is net made with en engineered connector, must be nailed ~n accordance with the nail schedule. RAFTER/TOP PLATE CONNECTORS: Each rafter must be connected to the well tap plate with e Simpson H8 connector following the manufacturer's specNicoUens (see drawing 04). RIDGE STRAPB: Ridge straps shall be attached to each pair of opposing rafters, Ridge strap connections meet the requirements given in table 5,4 of the W.F,C,M. OVERTURNING RESISTANCE: Floldowns ore provided on each end of ell shear walls in accordance wTth Bgure 2.2d of the W.F.C.M. Specific hardware is shown rn drawings OI and 02. ROOF SHEATHING: In the 4' perimeter edge zone of eli roof areas, 8d common naTIs wiIi be spaced 6" O,C. at panel edges and 12" at in~.crm~Giot~ supports in fha pond Reid In the interior zones, 6d common nails shall be spaced [n the some manner: 6" spacing at panel edges and 12" spacing at intermediate supports. These p~tterns meet the requirements ~f [he 120 mile per hour wind speeds on robie 3.B of the WFC.M WALL SHEATHING Wall sheathing attachment for oll exterior walls and oil inteBor sheer walls sh~lJ be 4" 0 C mt panel edges and 8" O.C at intermediate supporfs in the panel. FLOOR JOIST BRIDGING: Bridging shall be installed in ali floor framing systems between ]oTsts at 6 foot inter~ols, FLOOR DIAPHRAGM BRACINC: Blockmg and connections shall be provided, at panel edges perpendicular to floor framfng members in the first two bays of framing, end shall be spaced at o maximum of 4' O.C.. WOOD STUDS: All wood framing is Douglas fir #2. Exterior walls sro 2x6 framed wails with 3/4" inch plywood, Interior walls, unless noted otherwise are framed wNh 2x~-s. At oll corners, o minimum of three studs shall be used in dl wails, TOP PLATES Double top plates shall be provided at the top of all infeHor and exterior load bearing walls The double plates shall overlap at corners and et intersections with other exterior or interior load bearing wails, PROTECTION AT OPENINGS: Wood structural p~nels with o minimum thickness of 7/16 th inch Mil be made for placement df dj[ openings on the north exterior wall. These panels will be precut fo cover these glozed openings. The attachment will be 2-1/2" //6 screws, with 9" spacing a[ the perimeter, This screw and spacing is in accordance with Table 1609 1.4 5 CODE ANALYSIS §1204,1 general, Every space intended for human occupancy shall be provided wdh natural light by means of exterior ¢ozed openings in accordance with Section 120¢,2 or shall be provided with ortTBcTol light in accordance with Section 1204.B. Exterior glozed openings shall open directly onto o public way or onto o yard or court in accordance with Section 1205, §1202.4.1 VentiJotion area required The minimum openoble oreo to the uutdoors shall be 4 percent of the floor oreo being venDloted, §1204.2 Natural light The mlnlmum net glozed oreo shall not be less than B percent of fha floor oreo of fha room served, ARTIFICIAL MECHANICAL ROOM// SO, FT VENTING AREA VENTING GLAZING AREA GLAZING LIGHTING VENTING (sq,ft.) (%) (sq.ft.) (%) 101 415 41.82 10,1% 76.7 18.4% YES 03 LIGHTING & VENTILATION JOINT DESCRPqON NUMBER P(PE OF NAILS NAIL SPACING RAFTER TO TOP PLATE (TBE-NIALED) 6-8d PER RAFTER CEILING JOIST TO TOP PLATE (TOE-NIALED) 6 8d PER JOIST CEILING JOIST TO PARALLEL RA~ER (FACE-NAILED) 8-16d EACH LAP CEILING JOLST LApS OVER PARTITIONS (FACE-NAILED) 8 1Md EACH LAP COLLAR TIE TO RAFTER (FACE-NAILED) 8 8d PER TIE BLOCKIN,G TO RAFTER (TOE-NAILED) 5 8d EACHEND RiM JOIST TO RAFTER (END NAILED) S-16d EACH END TOP PLATE TO TOP PLATE (FACE NAILED) 3 16d PER FOOT TOP PLAkTES AT INTERSECTION (FACE-NAILED) 6-16d JOISTS EACH SIDE STUD TO) STUD (FACE-NAILED) 5 1Sd 2¢" O.C. NRADER TO HEADER (FACE-RAILED) 2 1Md tM" O.C. ALONG EDGES TOP OR BOSOM PLATE TO STUD (END NAILED) 5 19d PER 2 X 4 STUD 5 16d PER 2 X 6 STUD 6-16d PER 2 X 8 STUD BoTroM PLATE TO FLOOR, BAND, END, RIM JOIST OR 5-16d (1,2) PER FOOT BLOCKINIG (FACE-RAILED) JOIST TO SILL, TOP pLATE OR GIRDER (TOE RAILED) 6-8d PER JOIST BRIDGING TO JOIST (TOE NAILED) 5-8d EACH ENB BLOCKIN(G TO JOIST (TOE NAILED) S-ed EACH END BLOCKIN~G TO SILL OR TOP PLATE (TOE-NAILED) 5-16d EACH BLOCK LEDGER STRIP TO BEAM (FACE-NAILED) 5-16d EACH JOIST JOIST OrN LEDGER TO BEAM (TOE-NAILED) 5-8d PER JOIST RIM JOIST TO JOIST (TOE-NAILED) 5-16d PER JOIST RIM JOIST TO SILL OR TOP PLATE (TOE NAILED) 5 16d (1) PER FOOT SIMPSON H8 7 NAILING SCHEDULE SIMPSON HDIOA 04 SIMPSON CONNECTORS INBTALLATI(ON NOTES: ALL HOLDO~WNS USE ~" STUD MACHINE BOLTS (HDGA - 2, HDGA - 5, HDIOA 4) AND STEEL NYLON LOCKING NUTS ALL ANCHOR BOLTS ARE ~" DIAMETER FRAMING AT iNSTALLATION LOCATIONS WILL BE DOUBLED AND NAILED 3" O,C. MACHINE BOLTS MUST HAVE 3" OF BEARING IN VERTICAL MEMBERS BOLT HOLDS SHALL BE A MINIMUM OF ~2" TO A MAXIMUM OF Y16" LARGER MAN THE BOLT DIAMETER (PER 1997 NDS, SECTION 8,1.2.1) STANDARB ~WASHERS ARE REQUIRED ON STUD BOLTS AGAINST WOOD, NO WASHER IS REQUIRED ON LOAD TRANSFER PLATE OF HOLDOWN HOLDOWN ~ILL BE LOCATED FLUSH WITH BOSOM PLATE, EXCEPT WHERE TWO HOLDOWNS OCCUR WHERE TWO HOLDOWNS ARE INSTALLED ON THE SAME MEMBER, ONE HOLBOWN WILL BE INSTALLED FLUSH WiTH BOSOM PLATE AND ONE WILL BE S~WGGERED VERTICALLY ABOVE FIRST HOLDOWN ANCHOR B[OLT NUTS SHOULD BE FINGER TIGHT PLUS ~ TO ~ TURN WITH A WRENCH, WITH CONSIDErAtION GIVEN TO POSSIBLE FUTURE WOOD SHRIINKAGE. CARE SHOULD BE TAKEN NOT TO OVER TORQUE THE NUT. STUD BOLT!S SHOULD BE SNUGLY TIGHTENED (1997 NBS, SECTION 8 1.2,4) 02 HOLDOWN INSTALLATION ~ (10S T Il SIMPSON H8 SIMPSON I-lB10A 0~:~ KITCHEN ADDITION (2) SIMPSON HD10A1 02' (2) SIMPSON HDIOA] 1 KITCHEN ADDITION PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC 12.18.06 SCHEMATIC DESIGN 11.03.06 SCHEMATIC DESIGN 09,15.06 RDJISION ISSUE DATE BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC CODE ANALYSIS HALF SCALE PROJECT: 73 A601 U PLUMBING NOTES (Ni (N) SINK (N)TOILET- VENT THROUGH ROOF VENT THROUGH ROOF VENTTHROUGH ROOF ' OLEANOUT THIRD FLOOR- BATHROOM VENT THROUGH ROOF (N) TUB (N) (N) BINK (N) SINK (N)TOILET (N) 3"0 C.V. LINE CLEANOUT THIRD FLOOR- BATHROOM 1 DO NOT SCALE FROM RISER DIAGRAMS, 2, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE BUILDING CODE OF THE TOWN OF SODTHOLB AND RB-16. 3, OBTAIN AND PAY FOR ALL PERM[TS, CERTIFICATES, ETO, REQUIRED, 4, VERIFY FIELD CONDITIONS ARB LOCAL CODES BEFORE SUBMI1~ING BID, DELIVER CERTIFICATES OF FINALINBPEOTION TO OWNER BEFORE APPLYING FOR FINALPAYMENT, 6. PITCH HORIZONTAL DRAINAGE PIPING $" GIAMETER AND LESS 1/4" PER FOOT MINIMUM; OVER 3" CIA, PITCH 1/8" PER FOOT MINIMUM 7 SPACING BETWEEN OLEAN-OUTS SHALL NOT EXCEED 8. GUARANTEE ALL WORK FOR A PERIOD OF 1 (ONE)YEAR FROM DATE OF FINAL ACCEPTANCE 9. ALL HOT AND COLD WATER LINES TO HAVE SHUTOFF VALVES, (N) 3"0 STACK VENT ~ ~ ~ (N) TUB (N) 3"~ STACK VENT (N) TUB ~I = {N) 3"0 STACK VENT (N) SHOWER ~ / ~ (N) SHOWER I m- (N) B"l~ BTAOK VENT / / /~<N)S~NM ! (N)TUB-- /~ (N) SHOWER / ~(N)SINK I ~(N)TUB (N)S[NK~ ~ ~ ' / / --(N)SINK ~ ~(N)SINK (N)SINK~ ~ ~ ~ / / / --(N)SINK (N)SINK (N) TOILET ~ ]~ / // ~(N)TO LET ~ (N) TO IL~_ ~_ ~ (N)~AS H IN Gi~ / / V (N)TOILET · ~T (N)TOILET [ 2"~ !2"0 ,,0 1~ ~ ~ , ~ ~ ~ , " '~ , , , / // ~I , , , , , , , ~ '~¢ SECONDFLOOR-MASTERBATH SEC0NDFLOOR-BATHROOM2 "0 2" 8ECONDFLOOR-BATHROOM3 --2"¢ ~2~]i 2 I (N) 3"0 O,V, LINE I, ~ CLEANOUT CLEANOUT ~ ~ CLEANIOUT CLEANOUT ] ] (N)4"¢ CV. LiNE ' ~ + (N) 3"~ STACK VENT m ] N)DISH WASHER ~ (U) 3'IO STACK VENT m (N) 3'I¢ STACK VENT r N)DISH WASHER ,(N)TOILET 7 I i .2_~2 ~ L I m ~ '~ ~ FIRST FLOOR- PANTRY FIRST FLOOR. KITCHEN ~ FIRST FLOOR- BATHROOM 1 ~ (N) 3"¢ C.V. LINE ~ (N)3'~,LINE m ~OL~NOUT ~ CLEANOUT CL~NOUT ~ ~ (N) 4"0 C.V ~ (N) 3"0 STACK VENT (N) SINK (N) SINK ~, _(N) TOILET (N) TOILET ] 2"¢ " ~ (N}3"¢ C V. LINE ~ / ~ E ~ CLEANOUT ~"~CLEANOUT CLE¢ CLEANOUT PERMIT DOCUMENTS 01.1S.07 PARTIAL PERMIT DOC 12,:L8,06 SCHEMATIC DESIGN 11.03,06 SCHEMATIC DESIGN 09,15.06 REVISION ISSUE DATE BACClLE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC RISER DIAGRAMS HALF SCALE PROJECT: 73 P101 I I U L 2) 2 X 12 JOIST 18" 2 X 12 JOIST 16" O,C. 2 X 12 JOIST 16" O.C 2 X 12 JOIST 16" O.C 2 X 12 JOIST 16" O,C. 2 X 12 JOIST 16" OC 2 X 12 JOIST 16" 2 X 12 JOIST 16" O,C. 2 X 12 JOIST 16" O,C. 2 X 12 JOIST 16" O,C, 2 X 12 JOIST 15" FRAMING 2 X 12 RIMJOIST FRAMING 2 X 12 COMMON JOIST I I .I Ill SITE PILING BEE LINE OF NEW CONCRETE I/-- FOOTINB BELOW ALIGN TOP OF NEW FOUNDATION WALL WITH TOP OF EXISTINB FOUNDATION WALL LINE OF EXISTINO CONCRETE FOOTING BELOW F O~ FIRST FLOOR FRAMING PLAN ,I TOP OF FOOTING AT 4' BELOW FINISH GRADE LJ c~q ' FOO~NG 10" POURED CONCRETE FOUNDATION WALL ABOVE LINE OF EXISTING CONCRETE FOOTING 1 FOUNDATION AND FOOTING PLAN PERMIT DOCUMENTS 0'1,1G.07 PARTIAL PERMIT DOC 12.18,06 SCHEMATIC DESIGN 2L1.03.06 SCHEMATIC DESIGN 09.15.06 BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC FRAMING PLANS HALF SCALE PROJECT: 73 S101 I, I L '1 L 2 X 8 RAFTER 16" O.C, ',7 LINE OF EXISTING EAVE LINE OF EXISTING RIDGE /'"t.1 SECOND FLOOR FRAMING PLAN ~,// PERMIT DOCUMENTS 01.18.07 PARTIAL PERMIT DOC :L2.18,06 SCHEMATIC DESIGN :L~..03.06 SCHEMATIC DESIGN 09.15.06 RE,SION ISBUE DATE BACCILE HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC FRAMING PLANS HALF SCALE PROJECT: 73 S102 -- 2 8 RAFTER (2) 2 X 12 RIDGE BEA~ 1 ROOF FRAMING PLAN PERMIT DOCUMENTS PARTIAL PERMIT DOC SCHEMATIC DESIGN SCHEMATIC DESIGN 01.18.07 BACCILE HOUSE KiNLiN RUTHERFURD ARCHITECTS~ PLLC FRAMING PLANS HALF SCALE PROJECT: 73 S104