34942-Z
Town of Southold Annex P.O. Box 1179 54375 Main Road Southold, New York 11971 3/23/2012 CERTIFICATE OF OCCUPANCY No: 35503 THIS CERTll?lES that the building Location of Property: Date: 3/23/2012 ADDITION/ALTERATION 577 Pacific Street, Mattituck, SCTM #: 473889 Sec/Block/Lot: 141.-4-14.1 Subdivision: Filed Map No. conforms substantially to the Application for Building Permit heretofore 8/18/2009 pursuant to which Building Permit No. was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions and alterations, including rear deck and covered front entry, to an existing one family dwelling as applied for. Lot No. filed in this officed dated 34942 dated 8/18/2009 The certificate is issued to Janet Ciamaricone (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 2/14/12 34942 2/10/12 Shoreham Plumbing & Heating ~~Signature FORM .NO. TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUII/)ING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34942 Z Date AUGUST 18, 2009 Permission is hereby granted to: JOSEPH C CIAMARICONE PO BOX 1631 MATTITUCK,NY 11952 for : ALTERATIONS & ADDITIONS TO EXISTING ONE FAMILY DWELLING AS APPLIED FOR. ENGINEER CERT REQ BEFORE C/O. THIS PERMIT REPLACES BP27505. at premises located at 577 PACIFIC ST MATTITUCK County Tax Map No. 473889 Section 141 Block 0004 Lot No. 014. 001 pursuant to application dated AUGUST 18, 2009 and approved by the Building Inspector to expire on FEBRUARY 18, 2011. Fee $ 937.80 -'15~,oo P~ ~-I~-o~ Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUII/)ING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 27505 Z Date AUGUST 24, 2001 Permission is hereby granted to~ JOSEPH C CIAMARICONE PO BOX 1631 MATTITUCK,NY 11952 for : ALTERATIONS & ADDITIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR (ENGINEERS CERTIFICATION ON SEPTIC SYSTEM REQUIRED BEFORE CO) at pre~ises located at County Tax Map No. 473889 Section 141 pursuant to application dated JUNE Building Inspector. 577 PACIFIC ST MATTITUCK Block 0004 Lot No. 014.001 22, 2001 and approved by the Fee $ 937.80 Aut hor'/~d ~S~re Rev. 2/19/98 ORIGINAL Form No. 6 TOWN OF SOWI~IOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF occUPANcy This. application must be fill~d in by typewriter or ink and submitted to the Building Dq~artment with the following: A. For new building or new use: 1. Final ~rv~t of prop,aet'y with accUratelocation of all buildings, propes~y lines, streets, and unusual natural or topographic features. 2. Final Approwl from H~alth D~pt. of wat~ supply and s~w~rage..di~posfl (S-9 form). 3. Approval ofeleetrical installation from Board 6fF'n'~ Underwriters. 4. 'Sworn stat~nt from plumber certifying that tho sold~ used in system contains less than 2/10 of 1% lead.. 5. Comm~'oial building, industiial building, mttltiple reaidenoes and similar buildings and installations, a ccrtificata of Code Compliance'from architect or engineer responsible for the building= .6. Submit planning Board Approval of comple~..d site plan requir~me, nts. B. For existing buildings (prior to April 9, 1957} fion-confo~qning useS, or buildings and "Pre..existing' land uses: 1. Accurate survoy of property showing all property lines, streW, building and unusual natural or topographic feamres. 2. A properly o~mpleted application and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. C~ttiflcate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimmiug pool $50.00, Accessory building $50.00, Additions to accessory building $50 00, Businesses $50 ~. C~tiflcate of Occupancy on Pre-existing Building - $100.00 3. Copy of C. erlificate of.Occupancy - $:25 · 4. Updated Certificate of Occupancy - $50.00 · 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Date. (cheek one) Old or Pre-existing Building: Location of Property: House No. Street · or of Prop y: · ~om~ T~ Map No 10~, S~ion '[ q-t Su~sion P~mit lqo. ~ H~lth I>~ Agproval: Planning Board Approval: Request for: T~mporary ( Foe Submitted: $ ~' 0. Hamlet Block Lo,lq-. Date of Pcamit. Filed Map. Applicant:. Und~writers Approval: Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 rorer r chert~,town southold.ny, us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ssued To: Janet Ciamadcone ~,ddress: 585 (577) Paciflc St City:Mattituck St: NY Zip: 11952 3uilding Permit#: 34942 Section: 141 Block: 4 Lot: 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE ,;ontractor: as built DBA: License No: SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Commedcal Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Servicelph ~ Heat ~ Dup[ecRecpt ~ Service 3 ph Hot Water GFCl Recpt Main Panel NC Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment: Ceiling Fixtures [] HID Fixtures Wall Fixtures ~ Smoke Detectors Recessed Fixtures ~.~ CO Detectors Fluorescent Fixture [~ Pumps Emergency Fixtures~ Time Clocks Exit Fixtures [~ TVSS 200a overhead service, 4-paddle fans, 4-exhaust fans, 1-hydro massage tub Notes: Inspector Signature: Date: Feb 10 2012 81-Cert Electrical Compliance Form.xls Towfl ltall Ann~ Hew ¥od~ I t~ l-O~ TO~VN OF 90D'x'~tOI.,D .CERTIFICATION (Pleas~ p~int) I cer~if~ that the s~ldc~ u,~ iu .the ~ s~ply s,yst~m contat~ l~s .d~ 2/I 0 of ! ',4 lead. . . dayof [~/, 20/,,7_* JANET M., CAVALIERE Notary Public - State of New York No. 01CA6179024 Qualified in Suffolk County My Commission Expires December 17, 201~' 76S-1802 BUILDING DEPT. [ ~/] FOUNDATION 1ST [ ] PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: ~ _ DATE /'~/-~,0 /cO/ iNSPECTO~.d~ BUILDING DEPT. INSPECTION [ ] FOU~~IST [ ~j/FOUNDATION 2ND [ ] ROUGH PLBG. [ ] INSULATION [ ] FRAMING [ ]FINAL [ ] FIREPLACE & CHIMNEY REMARKS: ~~~'~ ~ DATE INSPECTION [ ] FOUNDATION 1ST [~] ROUGH PLBG. i ~OUN~ ~~ON2ND [[ ' i 'FiI~NU~LATION [ ] FIREPLA¢/~ CHIMNE'~_ DATE ~//~///~,,~ ,NSP--R ~~ 765-1~ BUILDING DF. PT. INSPECTION [ ] FOUNDATION 1ST [ ~ ROUGH PLBG. [ ] FOUNDATION2ND [ ]INSULATION [ ] FRAMING [ ]FINAL [ ] FIREPLACE & CHIMNEY /) BUILDING DEPT. INSPECTION /. [ ] FOUNDATION 1ST [ ] ~I~UGH PLBG. [ ] FOUNDATION 2ND [/*~ INSULATION [ ] FRAMING [ ]FINAL [ ] FIREPLACE & CHIM, N~'Y REMA~,RKS: ~~--- TOWN OI:~NG DEPT, INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] IN~dJLATION FRAMING / STRAPtqNG [~I:INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]FInEKESm'ANTC0m'rmJCT~ [ ]FlnEnESWr~n'PENEmATKXi [ ] ELECTRICAL (ROUGH) L ] ~=' ~ (fiNAL) DATE INSPECTION [ ] FOUNDATION t ST [ ] FOUNDATION 2ND [ ] FRAMING/STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] F~'r~~ [ [ ] ELECTRICAL (ROUGH) REMARKS: ROUGH PLBG. INSULATION FINAL FIRE SAFETY ~ ~_~ IRIMI.) DATE ~ ,NSPECTOR~~~~-~'~- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [/~FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION ] ELECTRICAL IFINAL) FIREPLACE & CHIMNEY fine I~lS'rMr ~ ELEmlCAL (ROUGH) REMARKS: DATE INSPECTOR File No: 5003 WARREN A. SAMBACH, SR. CONSUL~NG ENGINEERS · pLANNERS 7675 COX LANE - P.O. BOX 1033 CUTCHOGUE, NY 11935 6 3 1 ~734-7492 May 2 2003 Buildin~ D~partment To~n of Southold 53095 Main Road Southold NY 11971 Re: Joseph & Janet Ciamaricone 585 Pacific Street Mattituck NY 11952 SCTM: 1000-141-.04-14.1 Permit ~27505Z To Whom it May Concern: The framing installed conforms to the revised Plans and conforms to the New York State BuildinG Code. Sincerely, Warren A. Sambach Sr. P.E. was:s cc: Ciamaricone FIELD iNSPECTION REPORT- DATE .FOUI~)ATION ( IST)' F~y~DATION (21qD) ~ ~ ~SULA~OH~N. Y. STATE ENgR~ CODE FINAL TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 76S-1502 FAX: (6.31) 765-9502 SouthoidTown. NorthFork. net Examined ,20 Approved Disapproved a/c · 20 Expiration ,20 BtDG OEPl. 10!% OF SO[IIHOtD PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Single & Separate Storm-Water Assessment Form Contact: Mail to: Phone: Building inspector APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS .20 a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MA,DE to the Building Department for the issuance ora Building Permit pursuant to the Building Zone Ordinance of the Town of Sqmthold, Suflblk County, New York. and other applicable Laws, Ordinances or Regulations, for the construction of buiJdings, additions, or alterations or for removal or denrolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, ifa corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~c~x*...-L C~o,_~w, o..¢- t coo ¢ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. ' Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet CountyTax MapNo. 1000 Section It4~ Block q Lot t._{, [ Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy ~ c..k& ~ ,s ceil4 trnax //~ ~ ~ 3. Nature of work (check which applicable): New Building Addition ¢"" Alteration Repair Removal Demolition Other Work Estimated Cost Fee If dwelling, number of dwelling units If garage, number of cars (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear .Depth Dimensions of same structure with alterations or additions: Front Depth Height_ Number of Stories 8. Dimensions of entire new construction: Front i q J Rear. Height ,~ $'1~' Number of Stories I Rear .Depth il '~ ~''[z '~ 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ~ l 3. Will lot be re-graded? YES NO /~Will excess fill be removed from premises? YES NO ,-'" 14. Names of Owner of premises Name of Architect Name of Contractor Addressg~u~iiea23a&,hlmL~?hone No. 02'/ Address Phone No Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? * YES NO / · IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BEfl.EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO · IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO p-""" · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF 5,,,¢h,~. ) '3'o.x~-oDt C__x,.,.~,.oct c or~ being duly sworn, deposes and says that(s)he is the applicant CONNIE O. BUNCH (Name of individual signing contract) above named, Notary Public, Slate of Now Yor~ No. 01 BU6185050 (S)He is the O v.~ rx ~_--(' Qualified in Suffolk County ~ (Contractor, Agent, Corporate Officer, etc.) Oo,i,iii~ion Ex~pires April 14, of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements coatained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thj~ ~ w~qqtg day o f P'-~,~--~A-~. 204~ Notary Public Signature of Applicant TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: 765-1802 Examined a~;~ ,20q Approve~/~ .~.~ , 20~ Disapproved ~c PERMIT NO. BUILD~?~,q ?E[LMiT APPLICATION CHECKLIST you have or need the following, before applying '? Board of Health 3 sets of Building Plans f Survey ~ Check a;t eql~S · Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: ~"'C-~Ox~A APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS ,2O a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale· Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept o*n the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupancy is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. / ~6~'~nat~:e ;f applicant or name, if a corporation) (Mailing addres~ ofapplicafit) / State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (as on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. /~O 7/-- ,'~e'A-;/.~.L; P!nmbers License No. z c Electricians License No. // Other Trade's License No. // I. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section / q/ Block OL/ Subdivision Filed Map No. (Name) Lot Lot /¥./ 2. State existing use and occupancy ofpremises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~>\c~C, le,_ ~m,[~ c~L~l[tr'~ . ~ {tOAee'~rv, r~r2~A~n~a{~ b. Intended use and occupancy $~,x~,th/¢.. -¢c~j'm[,~\ Ck~*cl~c~iq [x-e~.crnrn 3. Nature of work (check which applicable): New Building Repair Re~mtat ~ Demolition 4. Estimated Co ~ t~. Fee 5. If dwelling, number of dwelling units If garage, number of cars Addition Other Work Alteration (Description) (to be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial.or mixed occupancy, specify nature and extent of each type of use. 7. Dimensionsofexistingstru, ctures, if any: Front /~/~,~ Rear ,z/~,5'"' Depth Height ~-~aj~,J :~ ~77~,r Number of Stories ~ -- Dim n ' - ' ~ e sions OT same structure with alterations or additions: Front Z/~ ~- Rear Depth. D_ ~/. ~' Height ,-~ d - /-) Number of Stories 8. Dimensions of entire new construction: Front /7/~', ,~ Rear Height ~ 0 - 0 Number of St(~ries ~._ / / 9. Size oflot: Front ?.q. O~ Rear ./.Z~_--",~d) Depth Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated ~'x (~) 12. Does proposed construction ;/ate any zoning law, ordinance or regulation: . 13. Will lot be re-graded./f'//~- _ Will excess fill be removed fi.om premises: Address Phone No. Address Phone No Address NO ~,~No. IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 14. Names of Owner of premises Name of Architect Name of ContraCtor 15. Is this property within 100 feet of a tidal wetland? *YES 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF being duly sworn, deposes and says that (s)he is the applicant (Name of individual s~gning contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this __ .,-~'D_ day of ~~.~ 20 d)O Notary Public Signature of Applicant Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERIY LOCATI0t~: S.C.TJ~I.~ THE FOLLOWING ACTIONS MAy REQUIRE THE SUBMISSION OF A ~ ) ~L~ Jn ~'~ ~t' ~ ~;TORM-WATEI~ GRADING, DRAINAGE AND EROSION CONTROL pLAN DIselct I~lOG~ CERTIFIED BY A DEEIGN PROFESSIONAL IN THE 6TATE OF NEW YORK, $COP~ OF WORK * PROPOSF~ CONSTRUC~ON rl'~f # / WORK~ESS~ I Yes No a. Whal is the Total ~ea of t~e Pro~ect I~uceis? (Include Total Area of ali Parceis iscatnd within I Wil thfs Preject Retain NI Storm-Watar Run-Off Itle Scope of Work for Propeesd Coflsl~uc~on) (This itam will Include all n Jrt-off created by sitaGenerated by a Two (2') inch Rainfall on Site? b. What is the Total Area o~ Land Cleadng (&F. I ~,ea) ir cleating and/or construction activities as well as all -- and/or Ground Disturbance for Ihe pmpesed Site Improvements and the permanent creatkm of constru~on activin?~ im~eedoue surfaces.) ~s.F.~,~) 2 Does the Site Pla~ and/or Survey Show NI Proposed PROIIIDE ER.TEl* PROJECT D~:~l}dj~IllON 0~ovi~,Ad~an*l Page~., N~) Drainage Structures IndloalJng Size & Location? This Item sh~ll include all Pmpesed Grade Cha~ges and __ t,.~:~CJ(~ ~ ~d'~ '~.,, 3 O°es the Sita Plan and/or Survey desc~be the emsl°n and sediment control practices that v, fll be used to · q control site erosion and storm water discharges. This item must be maintained throughout the Entire C~nslmctisn Pedod. 4 Will th~s Project Require any Land Filling, Grading or Excavation Where them Lsa change to the Natural ~ / Existing Grade Involving mom than 200 Cubic Yards of Material within any Pamer? ~ Will this Application Refl~Jire Land Dhsturbing Activities Encompassing an Area in Excess o[ Five Thousand (5,000 S.F.) Square Feet of Ground Surface? --v.-- 6 Is them a Natural Water Course Running thmagh the Site? is Ulis Plo]ect wilhin the Trustees juitsdlctkm~ .~..e~erel DEC SWPPP Requleements: Or within One Hundred (100') teat of a Wetland o~ -- which Excaed FiReen (15) feet of verlical Ries ta .... ,~,y ruu,c, b'la/e of New Yod~ STATE OF NEW YORK, No. 01BU6185050 COUNTY OF ........................................... SS Qualified in Suffolk County Commission Expires April 14 And that be/she i~ the ................ O..L~. CX.....~... O~mer and/or reprcsentalive of the Owner or Owners, ~u~d L~ duly anthorized to perform or have performed the said work and to make and file this application; that all statements contah~ed in this application are true to the best ofhi~ Imowledge and belief; and that ~.c work will be per[onned in the manner ~t forth in the application filed herewith. Sworn to before me this; FORM - 06/10 TOWN OF SOUTHOLD CHAPTER 236 - STORM WATER MANAGEMENT STORMWATER POLLUTION PREVENTION PLAN (SWPPP) General Town of Southold SWI'PP Requirements: (For Land Disturbance between 5,000 SF and I acre in area) 1. The SWPPP shall be prepared prior to the application for Building Permit. 2. The SWPPP shall describe the erosion and sediment control practices and where required, post-construction storm water management practices that will be used and/or constructed to reduce the pollutants in storm water discharges and to assure compliance with the terms and conditions of Town Code Chapter 236 for Storm Water Management prior to the issuance of a Town Building Permit. In addition, the SWPPP shall identify potential sources of pollution which may reasonably be expected to affect the quality of storm water discharges. 3. All SW-PPPs that require a post-construction storm water management practice component shall be prepared by a qualified design professional that is knowledgeable in the principles and practices of storm water management and treatment. 4. The owner, contractor or operator must keep the SW~PPP current so that it at alt times accurately documents the erosion and sediment control practices that are being used or will be used during construction, and all post-construction storm water management practices that will be constructed on the site. At a minimum, the owner, contractor or operator shall amend the SWPPP: a. whenever thc current provisions prove to be ineffective in minimizing pollutants in storm water discharges from the site; b. whenever there is a change in design, construction, or operation at the construction site that has or could have an effect on the discharge of pollutants; and c. to address issues or deficiencies identified during an inspection by a Building inspector, or other regulatory authority. 5. The Building Department may notify the owner, contractor or operator at any time that the SWPPP does not meet one or more of the minimum requirements of the building permit. The notification shall be in writing and identify the provisions of the SWPPP that require modification. Within fourteen (14) calendar days of such notification, or as otherwise indicated by the Town, the owner, contractor or operator shall make the required changes to the SWPPP and submit written notification to the Town that the changes have been made. If thc owner, contractor or operator does not respond to the Town's comments in the specified time frame, the Town may issue a stop work order and/or suspend the current Building Permit. 6. Prior to the commencement of construction activity, the owner, contractor or operator must identify the contractor(s) and subcontractor(s) that will be responsible for installing, constructing, repairing, replacing, inspecting and maintaining the erosion and sediment control practices included in the SW'PPP; and the contractor(s) and subcontractor(s) that will be responsible for constructing the post- construction storm water management practices included in the SW'PPP. The owner, contractor or operator shall have each of the contractors and subcontractors identify at least one person ~om their company that will be responsible for implementation of the SWPPP. 7. The owner, contractor or operator shall have each of the contractors and subcontractors identified in item # 6 above sign a copy of the following certification statement below before they commence any construction activity: "I hereby certify that I understand and agree to comply with thc terms and conditions of the SWPPP and agree to implement any corrective actions identified by the building inspector during a site inspection. In addition to providing the certification statement above, the certification page must also identify the specific elements of the SWPPP that each contractor and subcontractor will be responsible for and include the name and title of the person providing the signature; the name and title of the contractor responsible for SWPPP implementation; the name, address and telephone number of the contracting firm; the address (or other identifying description) of the site; and the date the certification statement is signed. The owner, contractor or operator shall attach the certification statement(s) to the copy of the SWPPP that is maintained at the construction site. If new or additional contractors are hired to implement measures identified in the SWPPP after construction has commenced, they must also sign the certification statement and provide the information listed above. 8. Erosion and sediment control component - All SWPPPs prepared pursuant to a Building Pc, milt Application shall include erosion and sediment control practices designed to comply with Town Code Chapter 236 for Storm Water Management and implement site improvements for Erosion and Sediment Control. Where erosion and sediment control practices are provided, the owner, contractor or operator must demonstrate that, at a minimum, the erosion and sediment control component of the Town SWPPP shall include the following: a. Background information about the scope of the project, including the location, type and size of project; b. A site map/construction drawing(s) for the project, including a general location map. At a minimum, the site map shall show the total site area; all improvements; areas of disturbance; areas that will not be disturbed; existing vegetation; on-site and adjacent off-site surface water(s), wetlands and drainage patterns that could be affected by the consmaction activity; existing and final slopes; locations of different soil types with boundaries; material, waste, borrow or equipment storage areas located on adjacent properties; and location(s) of the storm water discharge(s); c. A description of the soil(s) present at the site, including a test hole indicating depth of ground water; d. A construction phasing plan and sequence of operations describing the intended order of construction activities, including clearing and grubbing, excavation and grading, utility and infrastructure installation and any other activity at thc site that results in soil disturbance; e. A description of the minimum erosion and sediment control practices to be installed or implemented for each construction activity that will result in soil disturbance. Include a schedule that identifies the timing of initial placement or implementation of each erosion and sediment control practice and the minimum time fi'ames that each practice should remain in place or be implemented; f. A temporary and permanent soil stabilization plan that meets the requirements of the most current version of the technical standard, New York State Standards and Specifications for Erosion and Sediment Control, for each stage of the project, including initial land cleating and grabbing to project completion and achievement of final stabil/zation; g. A site map/construction drawing(s) showing the specific location(s), size(s), and length(s) of each erosion and sediment control practice; h. The dimensions, material specifications, installation details, and operation and maintenance requirements for all erosion and sediment control practices. Include the location and sizing of any temporary sediment basins and structural practices that will be used to divert flows fi.om exposed soils; i. A maintenance inspection schedule for the contractor(s) to ensure continuous and effective operation of the erosion and sediment control practices. The maintenance inspection schedule shall be in accordance with the requirements in the most current version of the technical standard, New York State Standards and Specifications for Erosion and Sediment Control; j. A description oft. he pollution prevention measures that will be used to control litter, construction chemicals and construction debris fi.om becoming a pollutant source in the storm water discharges; Required SWPPP Contents: Town of Soutltold Storm Water Pollution Prevention Plan: (For Land Disturbance between 5,000 SF and 1 acre in area) MINIMUM SITE PLAN REQUIREMENTS: 1. Applicant information: Provide name, legal address, and telephone number. 2. Common address, Suffolk County Tax Map No. and legal description of site. 3. Signature and stamp of registered Design Professional (Architect/Engineer/Surveyor) and/or design/owner certification. 4. Vicinity map. Existing and proposed mapping and plans (Maximum scale of 1" = 50' or greater detail) which illustrate at a minimum: C) Existing and proposed topography (minimum of 2-foot contours recommended); © Perennial and intermittent streams and/or Natural Water Course; (~ Mapping of predominant soils and location of test hole or site-specific borehole investigations that have been performed; C) Boundaries of existing predominant vegetation and proposed limits of clearing; 1~ Location and boundaries of resource protection areas such as wetlands, lakes, ponds, and other setbacks (e.g., stream buffers, drinking water well setbacks, septic setbacks); Location of existing and proposed roads, buildings, and other structures; Location of existing and proposed utilities (e.g., water, sewer, gas, electric) and easements; (~ Location of existing and proposed conveyance systems such as grass channels, swales, storm drains or other storm water BMP's; O Flow paths; (~ Location of floodplain/floodway limits and relationship of site to upstream and downstream properties and drainages; C) Location and dimensions of proposed channel modifications, such as bridge or culvert crossings where applicable; 1~ Location, size, maintenance access, and limits of disturbance of proposed structural storm water Management practices; Representative cross-section and profile drawings and details of structural storm water Management practices and conveyances (i.e., storm drains, open channels, swales, etc.) which include: O Existing and proposed structural elevations (e.g., invert of pipes, manholes, etc.); O Design water surface elevations; O Structural details of outlet structures, embankments, spillways, stilling basins, grade control structures, conveyance channels, etc.; (~ Logs of test hole investigations that have been performed indicating soil type and water table elevations along with a supporting geotechnical report where applicable. o Drainage Calculations for all structural components of storm water system to meet the minimum requirements of Town Code Chapter 236 for Storm Water Management. (e.g., Catch Basins, storm drains, open channels, swales, Best Management practices, etc.)for applicable design storms including: (~ Existing condition drainage swale areas, runoff rates, quantities of runoff generated by impervious surfaces, storm water velocities, and surface water elevations showing methedologies used and supporting calculations; (~) Proposed containment area, runoff rates, volumes, velocities, water surface elevations, and routing showing the methodologies used and supporting calculations; C) Final sizing calculations for structural storm water Management practices including, contributing drainage area, storage capacity, piping and outlet configuration; (~ Final analysis of potential downstream impact/effects of project, where necessary; 8. Final landscaping plans for structural storm water Management practices and any site reforestation or re-vegetation. 9. Structural calculations, where necessary. 10.Applicable construction specifications. 11. Erosion and sediment control plan that at a minimum meets the requirements of the local Erosion and Sediment Control Guidelines. 12. Sequence of construction. 13. Maintenance plan which will include: O Name, address, and phone number of responsible parties for maintenance; (~ Description of annual maintenance tasks; (~) Description of applicable easements; ~) Minimum vegetative cover requirements; (~ Access and safety issues; ~ Testing and disposal of sediments that will likely be necessary. 14. Evidence of acquisition of all applicable local and non-local permits. 15. Evidence of acquisition of all necessary legal agreements (e.g., easements, covenants, land trusts, etc.). Town Hall Annex 54375 ~ Road P-O. Box 1179 Sobthold, NY 11971-0959 Telephone (631) 76.~150~ r ' (6~1) ? o.qer, nchertCi~'ow((n.so7 uc~.n¥.us BUILDING DEPARTMENT TOWN OF SOUTHOI,I~ APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Company Name: Date: Name: License No.:~ Address: Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: 47' *Address': *C~ss Street: ~k~ ~ · *Phone No.: · Permit No.: % c~c-~ ~_~ Tax Map District: 1000 Section: ~4t/' Block: *BRIEF DESCRIPTION OF WORK (Please Pdnt Clearly) (Please Circle All That Apply) *Is job ready for inspection: *Do you need a Temp Certificate: Temp Information(If needed] *Service Size: 1 Phase 3Phase *New Sewice: Re-connect Additional Information: 82-Request for Inspection Form YES / NO Rough In YES / NO Final 100 1'50 200 300 350 400 Other Underground Number of Meters Change of Service Overhead PAYMENT DUE WITH/~P,PLICATION ' ~ ~i'OWN OF SOUTHOLD PROPERTY RECORD CARD OWNER FOR~EK OWNER LAND FARM ~OG, O NORMAL Acre TOTAL DATE ¢' 2/.z~/ VILLAGE COMM. CB. MIC$. D~T. SUB. ACR. Mkt. /alue LOT AGE BUILDING CONDITION NEW BELOW ABOVE FARM Tillable FRONTAGE ON WATER Woodland Meadowlond Value Per Value Acre House Plot Total FRONTAGE ON ROAD DEPTH BULKHEAD DOCK COLOR TRIM M. Bldg. Extension Extension Extension Porch Foundation Basement Bath Floors Porch Ext. Walls Interior Finish Breezeway Fire Place Heat Garage Type Roof Rooms 1st Floor Patio Recreation Room Rooms 2nd Floor O.B. Dormer Driveway Total I~inette OWNER STREET --~-,-.,.,.-v ~ RECORD CARD VILLAGE SUB. LOT BUILDING OWNER ~Es. 3r..~ ~ LAND N IMP. AGE NEW NORMAL FARM Tillable Woodland MeaSowland House Plot Total Acre TOTAL DATE ¥ BUILDING CONDITION BELOW ABOVE Value Per V~lue Acre W COMM. CB. MICS. REMARKS Mkt. Value FRONTAGE ON WATER FRONTAGE ON ROAD DEPTH BULKHEAD DOCK ,COLOR TRIM ~orch )orch ~reezeway Garage Patio O,B. Total o Foundation Basement Walls IFire Place Roof Recreation Room Interior Finish 1st Floor 2nd Floor Driveway LR. STATE OF NEW YORK ) COUNTY OF SUFFOLK ) , being duly sworn, deposes and says: That deponent is over the age of 18 years, and resides at / 2oo/ That on the ~ ~ day of ~¢~ , 1~, deponent, being the .~tJengineer, licensed by the State of New York, hereby states that,~C/he accepts full responsibility for the accompanying plans compliance with the New York State Fire Prevention and Building Co_de (9 NYCRR). Sworn to before me this ¢c~,o ¢,~ day of O-~.z~ 1999. Notary Public cc: applicant WARREN A. SAMBACH, SR. CONSULTING ENGINEERS · PLANNERS 7675 COX LANE · Re BOX 1033 CUTCHOGUE, NY 11935 6 3 1 -- ~ 734-7492 August 23 2001 Building Department Town of Southold P.O. Box 1170 53095 Main Road Southold NY 11971 Re: Joseph C. Ciamaricone 585 Pacific Street Mattituck NY 11952 SCTM 1000-141-04-13 Gentlemen: The sanitary sewerage system has to be ungraded to a septic tank of 1000 gallon minimum due to the installation of an additional bedroom, making a total of four (4) bedrooms. The leaching pools are more than Warren A. Sambach Sr. P.E. adequate for the flow. WaS:S · Complete Items 1, 2~ and 3. Nee ~ item 4 If Restricted Delive~ Is desired. · Pdnt your name and addm~ on the reveme · Attach this card to the back of the mallpiece, or on the f~o~t If space pennl~. 2. Article Number (Transfer ~om service/abe/) O. ~ de~ eddmes d~s~e~t ~ Earn 17 ~Yea PS Form 3811, February 2004 Domestic RetumReceipt · Complete items 1, 2, and 3. Also complete Rem 4 if Restricted Del[very ia desired. · Print your name and address on the reverse so that we can return the card to you. · Attach this card to the back of the maifpiece, or on the front if space permits. 1. Ar[icleAddressedto: D. Is delivery addrees different fTOm ite~3 1 ?, If YES, enter delivery address beicw: 4. Restricted Delivery? (Extra Fee) r'l Yes PS Fom~ 3811, February 2004 Domestic Return Rscaipt 102595~2-M-1540 · Complete Rems 1,2, and 3. Also c~rnplete item 4 if Restricted Delivery is desired. · Print your name and address on the reverse so that we can return the card to you. · Attach this card to,the back of the mailpiece, or on the front if space permits. 1. Article Addressedto: ~3~ D. Is dailve~ addmes different from item 1 ? If YES, enter delivery address below: [] No 2. Article Number 0'rahs fer Oom sew/ce/abe/) 3. Service Type i-I Certified Mall [] Express Mall [] Registered [] Retum Receipt for Merchandise [] Insured Mai[ [] C.O.D. 4. Restricted Daiivery? (Extra Fee) [] Yes ; PS Form 3811, February 2004 Domestic Return Receipt //9 5a~- Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971~0959 Fax (63 l) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD MAY 2nd ,2006 Joseph C. Ciamaricone P.O. 1631 Mattituck, NY 11952 RE: 577 Pacific St. S.C.T.M. #141 0004 014.001 Dear Mr. Ciamaricone, Please be advised that your Building Permit # 27505 issued Aug. 24th, 2001 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $937.80 At that time we can schedule an inspection by one of our Building Inspector's· If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. K. Miller Clerk Typist Town Hall. 53095 Main Road P.O. Box 1179 Southold. New York 11971-0959 Fax (631 ) 765-9502 Telephone (631 ) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTI-IOLD January 30th, 2007 Joseph Ciamaricone P.O. Box 1631 Mattituck, N.Y. 11952 RE: 577 Pacific St. (Additions/alteration) SCTM# 141 4 14 i 2nd NOTICE Dear Mr. Cimino, Please be advised that your Building Permit #27505 issued August 24th, 2001 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $937.80 that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. Town Hall, 53095 Main Road P.O. Box 1179 Southold~ New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOLITHOLD October 2nd, 2007 Joseph & Janet Ciamaricone P.O. Box 1631 Mattituck, N.Y. 11952 FINAL NOTICE RE: 577 Pacific St. (Addition/Alteration) SCTM # 141 4 14 1 Dear Mr. & Mrs. Ciamaricone, Please be advised that your Building Permit #27505 issued August 24th 2001 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of 937.80; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILD1NG DEPT. Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631 ) 765-1802 Fax (631 ) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD June 2nd,2009 ,Toseph &,Tanet Ciamaricone P.O. Box 1631 Mattituck, N.Y. 11952 Re: 5?'/' Pacific Street SCTM# 1000-141.-4-14.1 Violation To Whom This May Concern: Your Building Permit # 27505 for Additions and Alterations to a Single Family Dwelling has been referred to me, because you have not responded to requests to obtain your certificate of occupancy as required by Southold Town code. Pursuant to 144-15A, of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Therefore, you have ten days from the receipt of this letter to submit a check made out to the Town of Southold in the amount of $937.80: to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. 7008 1830 0004 5083 3525 July 23, 2009 To: Southold Town Building Department Mike Verity Re: 577 Pacific Street SCTM# 1000-141.-4-14.1 Permit # 27505 This letter is in response to a letter sent to me on June 2, 2009. Mike as per our conversation I am writing to ask for an extension with my permit. Due to my husbands illness we have been unable to complete the final items needed for the certificate of occupancy. I had been saving money to renew my permit, but my husbands illness has progressed to liver cancer, And I needed to use that money for the cost of his care, and travel to N.Y for his treatments. I would appreciate it ifI could send in money when available to put towards the permit. As we discussed ifI could slowly pay off the permit fee, that would be greatly appreciated. I have enclosed a check for 150.00 to be put towards the permit. Respectfully, Janet Ciamaricone 585 Pacific Street Mattitick, N.Y. 11952 631-298-8588 Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 Janua~27 2012 BUILDING DEPARTMENT TOWN OFSOUTHOLD Janet Ciamaricone PO Box 1631 Mattituck, NY 11952 TO WHOM IT MAY CONCERN: The Following Item(s) Are Needed To Complete Your Certificate of Occupancy: *NOTE: Building Permits are still required for the Above Ground Pool, Shed and Rear Deck. ~:~' Application for Certificate of Occupancy. (Enclosed) ~' Electrical Underwriters Certificate. ~Afee of $50.00 __ Final Health Department Approval. t~/~ Plumbers Solder Certificate. (All permits involving plumbing after 4/1184) Trustees Certificate of Compliance. (Town Trustees #765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. - Bob Fisher Final Landmark Preservation approval. BUILDING PERMIT: 34942- Addition/Alterations ~ ~ao /ZOI ZONE ZONE AE (EL 11) X RM 82 ZONE PIKE ZONE X X ZONE X 3 X ZONE X 81 -EGION Town of Southold 360813 AVE J tr~uopo~ 1983 *Coastal 513 (EL ®M1.5 **Referenced t~, B EFF N/OIF coRNER REALTY N.83o5Z' 00" E. 0 S.?9o 05' 00" ~/' N /0/ F jusTYN& G. sLAG& MARTIN Prepared in a~ordan¢~ with the minimum standards for title sur~/s as establishec~ by the L L A. L. $. and approved and adopl~d ~or such use by The New York Stme Land Title Association. · . SURVEY OF PROPERTY ?,.%z. 68'% z6 A T . MA TTI TUCK ./o'/~ . w,;c~"s'" - TOWN OF SOU'THOL D " ~"'~"'~ °' SUFFOLK COUNTY ,~t.C E. NSKI ~, ROAO SCALE I"= 40' JUNE 2.0, 1989 GRiFFiN~$ coRNER RE<Y 14 /0! F juSTYN& G. SLAG& 8, MARTIN L. GRIFFIN N.8505~ O0 E. ON 0 OB · (IUe) ~'~ : sOzo ' AREA = 35,525 SO.FT. 262.66' '~ w~CE. NS~l \ ~ R°AD t.~ G~O~ CERTIFIED TO; PECONtC ABSTRACT INC. ~OUTIfOLD SAVINGS BARK JOSEPH C. CIAMARICONE JANET, F. CIAMARICONE Prepared in accordance with the minimum standards for title surve)~s as established by the L.I.A.L.S. and approved and adopted for such use by The New York State Land Title Association. SURVEY OF PROPERTY AT MA TTI TUCK TOWN OF SOUTHOL D SUFFOLK COUNTY , N.Y. I000 -- 141 - 04 - I,,'3 SCALE I",, 40' ,JUNE 20,.1989 '89 ENERGY CODE CALCULATIONS. /For Non-Electric lleat) r qriC O Design Criteria 6,UOU Degree'Says O.A. iU"F i.A. 70°F SUBSYSTEM L,x[~er~o. wail'~ (Opaque) Glazing /2 % Doors Ceiling/ tool (Opaque) skylights · % Floor Foundation Wails Slab insulation REMARKS TOTAL ti ote s_: l]uildiug Envelope Systems to meet requi]:ements of 7815.2 HVAC Equipement %o meet requ2rement of, 7U15.11 HVAC Systems to meet requirements of 7815.r2 Duct Systems to mee~ requiremehts o[ 7g15.13 Veutilatious Systems to meet requiremm ts o~ 7815.14 Insulation of Piping Systems to meet requ~relients of '1815.i5 Service Water Heating Systems & Equzp ent to meed requzre ents of 7815.21 Electrical & Lighting Systems & Equlplent to meet requirements of 7~].5-3ii 't'o tile best of my knowledge, belief, ~ professional judgenlent, the~e plalls are compliance with tile code. 39'-0" 5' 10" 10'-0" 3' 2" - DECK EXISTING HOUSE~,~ EXISTING HOUSE 25'-10;A" FRONT 1¢-¢' PORCH ZO 4'-10" 4'-7~,~'' 6'-4" i 6'-4" 6'-4" 4'-81/2'' 5'-10" /,/~ ~ C 3' BELOW GRADE +~ , ~ 2x8 LEDGER 7'-0" ~ 5'-11" 7'-0" 2x8 LEDGER ~ . ,,,, ,.~,,. ~. ,,,,, , ~ EXiSTiNG HOUSE '' REA~ '-" EXISTING HOUSE' ]' BELOW GRADE 25' IO;A" 11'-0" " FRONT FRONT ELEVATION LEFT ELEVATION RIGHT ELEVATION REAR ELEVATION ~EC.t<. ~. POF~CH C. oNSTf~UC. TION I~ET,~,IL5 ~ LUIN~:) LO~,~ P,~,TN C.ONNEC,TION IDET,,&IL5 CROSS SECTION A-A ASHFHALT ROOF 15# FELT iI- CROSS SECTION B-B _POST T8 DE{CK/PORCH CONNECTION MIN, 3' HIGH THICK DECKING ANT C,oNSTR. UC,TION C.ONNiEC,TO~6 CLIMATIC & GEOGRAPHIC DESIGN CRITEIIA DECK AND COVERED PORCH NOTES: NAILING SCHEDULE ROOF FRAMING: WALL FRAMING: DECK/PORCH FRAMING: ROOF SHEATHING: JDINTDE$CRIPTION ~ ~P~LNG NOTES DECI4. ~ POf~CH CONSTR~.UCTION DETAIL5 4~ ~IND LOA~ P~TH CONNECTION DET~IL~ N~DE~ NAILING SCHEDULE ~FTE~ ROOF F~MING: ;: ~ ~ ' ~ ' I'o'"~"'~'o~ "~'~ ~'~ . ................ ~ ~ *~ ~. PO~T/COL~MN- ~ · ~ WALL FRAMING: CC ' ' ' 2x~ ~T L ~ % / ~I~/~BCK JOIST , ~ ~ fOpp~TETO PER s' ~c~ow , m~l~l~ DECK/PORCH FRAMING: j_~'ll~lll~ ~1 ~ ~ ~ ~ ~ ~I~E~/NE~E~ JOINTDESCRIPTION ~AI~ NAIL NOTES CROSS SECTION A-A ~co~ © ~'~"~""~ ~ ~"~" ~=~ .~,~ DECKING DECK AND COVERED PORCH NOTES: CROSS SECTION B-B PRONT NEW FRONT I LEFT ELEVATION (1) CHANOED TWO S~ALLgR .,, P~hi= _EVA : L'D COPY~I~'HT LAW. , ', ~t ~N$ rs't REAR ELEVATION RIGHT ELEVATION FAS P~l~ )PAF~ q~ ~DE~OK}, i:H[{ RiGH1 TG ~U}LI)'O~LJY ONE t~'{RLE',TL~p F~Oiq B' P, ~ FOUNOATION WALL . .C~I 16eX 8" cone. ,FTG .I 2x4 WALL J OF SUBR:OOR 8"x 24" CONC ,PIER WITH ~ (~) ~ REeAf~ EQUAU.Y SPAC?. ~ (TOP OF EIER TO BE MtN oF 12' '""~ BELOW FINAL GRADE.)PfER TO '~. r BE SET ON 1B"x 2O"x 8" CONC. I __ FTQ. (Tm.) (3) i~5 REBAR EQUALLY (TOP OF PIER TO BE MIN OF 12" ~re. (Tm.) L 8" P..C. ,F. OUNDAllON WALL ~ ON t6 x B CONC. FTG (MIN. '"'-. 3'-0" BELOW FINAL GRADE,) II, SurE ALL FOOliNGS ARE'I MAINTAINED AT 38" BELOW FINAL GRADE NOTE: ] 3098 DOOR TO BE SET IN 2x8 CCA BuCK §"x 5" BOXED COLUMN ONCONC. WALLS NEW ~AJS 10 x 11-7/B' - 16" oc~ NEW ~-A,JS 10 x 11-7/8" - 16' DC NEW INSURE FOO~NGS AkRE MAINTAINED AT 36' BELOW RNIAL GRADE AT BASE OF STNRS AND DOORWAY ROOM 4' P.c. SLAB VENT (FURNACE) FURNACE AREA NOTE: 2x8 PS6 DOOR TO BE SET IN 6"x 6" B(OXED COLUMN ON 12' S~ONA TUBES CONC. FO)OTINGS. (MIN 3'-0" BELLOW FINAL GRADE.) r 2" P.C, SLAB CONC. PATIO NOTE:ALL MEASUREMEN'P~ ARE TO BE VERIFIED IN RELD PRIOR TO CONSTRUCTION. 2' P.C, SLAB ' ~L 2' P.C. SLAB INSURE FINIS' FLOOR HEIGHTS MATCH. I MAINTAINED AT 56" BELOW FNAL GRADE VERIFY NUMBE~R OF RISER REQUIRE:D I WITH FINAL GRIADE FOUNDATION PLAN PROVIDE MIN. R-19 INSULA]]ON BETWEEN FLOORS. ~ INDICATES FOUNDA~ON CHANGES MADE AFTER PLAN WERE SUBMITTED FOR PERMIT NO~ INSURE CONC, FOUNOA~ON HGT, ALLOWS FOE HGT, . OI~'~REI~ iN ELO0~ 09~07.~01 INOICA1ES F~NDATION CHANGES MADE. (J) ~A~ ~A~ WAS ~AN~D INTO ~ HELOT F~NDA~ ' , (2) ~0o~ ~ W~s CH~ moa : , , (3) DU~ WA~ TO BE ~TAL~ IN " (5) NEW C~U'MN P~T,~E TO S~NR, L~A~OH (6) F~flD&~ON WA~ ~ UP DE,ND ~00R (7) EX~R[~ STA R~ PRODDED. m . ' PLUS HAY NOT BE REPROOUCED WITHOUT WRITTEN ~THORtZA~I,ON. , ~L PLANS AND'DESIGNS ARE ~HE EAST END DEAFT~N~ THE RIGHT 8"x 8' BOXED COLUMN PROVIB£ H ANDP~AIL AS PER NYS COPE. 2446 244.2 LIBRARY ~ DINETTE SC~c~T AT SAME ADJUST TO INSURE J REm PRIOR ,tO CONSmUC'II0N. J : DINING ROOM 1846 2446 GIRDER , _ I-i - - 1846 FWG6061') ,F'W~3,~I lS 244,6 5' 2446 PROVIDE HANDRAIL AS PER NYS COPE. PROVIDE HANDRAIL AS PER NYS CODE. NOTE: ALL MEASUREMENTS ,, ARE TO BE 'vERIFIED ,IN I t To I FIRST FLOOR [/,//111I,~.'1 IHDICATES DHANOES MAD£ ON FIRST FLOOR ALL ER~ERIOR WALLS ARE TO BE , , NSULATEQ ~'~1 R-13 INSULATION, PROVEDE R,-.~O INSUIJk~ION B~llM[EN FLOORS. ALL IN~ERIOR WALLS ARE TO BE INSULATED ~lH R-11 IHS[ILATION. lb¸ NOT[: OMiT NEW FRONT PORCH AT THIS 1 (~S~NO TO R~MAIN) 244.2 2442 (2) ,1/;' (~) t-:~/~.' x 24¢2 4/2' 2442 244.2 BEDROOM (3) 2x8 BEDROOM MASTER BATH RO~S ~ TO BE ^'n-Ac~Eo NEW .~ 2x8--16" oc HUNG, FEOM RIDGE 0 9'--7 1/~' ' CEUJNG' ~IOISTS ~ LUPPER DECK PROVIDE HANDRAILS AS PER NYS. CODE. 2042 J SECOND FLOOR PLAN ALL EXTERIOR WALLS ARE TO BE PROVIDE R-30 INSULA~ON __ tTHIS WALL ~MLL BE SHORTER THAN OUTER WALL.(TO ALLOW FOR FASCIA TO LINE UP,) n l,I il I NOTE: OMiT NEW PORCH AT ]HFS TIME ([x~S'nN¢ To REM*4N) ROOF PLAN 2x8 RA~ lej¢$~16" o¢i I II II J 2x8 RAFTERS-16" 2X10 RAFTERS ~2xB RAF1~RS-!e" O~ ~2xe BAr-IERS-I8' ~.; ~QRMER WALL TO BE BUILT ON (,tl) 2xi0 RAFTERS I:/2"'CDX E~T.:ROD~SHEA'r~iNG' 2xS~-le' OC P-A~¥Ei~ ' FASCia DOUBLE 2~4,~16' l/2",'cox 18" il2 RED ~*x4 PLAT ' 2X4 G 8ACK INSULATION INSULATION i)AMP 2~4 KEY ,r-o" ~ 12 ~c w~ ~DS ',, NEW JNSULA~Ot D ~R R~C~ONS (6' EXF), · R-13 Oc WALL S~DS ~ m 0 SHEA~ING. -R-13 IN,LA,ON ~ ~ 3x~,~/~' s~ R-50 INSU~ON 719 INSULA~ON 3oF;Ne., FOUN~A~ ~y, ,, ~ ,;, CROSS SECT ,ON A 25 YEr ARCHITECTURAL GRADE ROOF SFflNDLE 1~ FELT , 1127 cox EX]'. ' ' ~ HURRICANE CUPS B' FASCIA 18 VENTED SOFfiT (SEE DETAIL) DOUBLE 2x4 PLATE 2X4-16" o¢ WALL STUDS 1/2" COX SHEATHING ~5' FELT 18" ~. RED CEDAR PERFECTIONS (8" EXP) - 2x4 PLATE DOUBLE 2x4 PLATE '.. 2x~-16' ac WALL S~JDS 1/2' CDX SHEATHINC 15' FELT 1B'~2 RED CEDAR PERF~ONS (*' EXP 2x4 PLA'TE DAMP PROOFING B" P. C. FOUNDA~ON WALL 2x~ KEY WAY 16" x B" CON~RETEFOO~NG 3'-0~ BELOW RN~L GRADE. (TYP.) RJDGE VENT 2x1.0 RIDGE ASrl9 R-30 ~ INSULATION J .3 INSULATION ' c~)x SUB INSULATION -- R--13 INSULATION ~/8" CDX SUB ~ OR MATCH EXISllNG .r INSULATION OC VIEW (PAGE 1 OF 1 CROSS SECTION B HURRICANE CUPS -- R-13 INSULATION 13 rNSULA~ON OF BEAM ARE TO BE GLUED,NAILED AND. (2) 1" STEEL NUTS 5-3/~'x 8'x STEEL PLATE / ,..-- I~3/4"x 11-7/8" / LVL BEAM coX PLYWOOD 1-3/4"x 11-7/B' ' LVL BEAM (2) 1~ sTEE~ NUTS -3/4, x e x 3/8' STEEL PLATE BUILT-UP BEAM (SE£ ABOVE DETAIL) .7 0 2~5 YR. ARCHITECTURAL GRADE' ROOF SHINGbE ~51~ FELT 1/2" CDX EXT, ROOF SHEATHING 2x6-16'~ oc RAETER~ RIDGE VEN1 2x8 RIDGE ., 12 RIDGE VENT 7 +?mi 2x10 RDGE HURRICANE 6' FASCIA , , ; 18 VENTED SOFFIT (SEE DETAIL). DOUBLE 2x4- PLATE 2x¢-16" od WALL STUDS 1/2' COX SHEATHING tB" ~2'RED CEDAR .PERF~C~ONS (B" EXP)~ .2x4 PLA~ R-SS )N~(' ATION 8' P, C, FOUNDA~ON WALL 2x~ EEYwAY ' ,' 16"X 8"CONCRE,TEFOOTING 3!-0' BELOW ~NALGRAD~ (TYR.) 2' PC SLAB R-lg iNSULATION -- CRqSS SECT C , tON VERIFY NEW FLOOR HEIGHT TO MATCH EXI'STINQ FLOOR HEIGHT, CUPS 2x6 SOFFIT 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE I§~FELT 1/2' COX EX~ ROOF SHEATrHING 2xS-1B" Dc RAFTERS 6" FASCIA 18 VENTED SOFFIT[ (SEE DETAIL) DOUBLE 2x4 PLA]IR 2x4-16" Ge WALL. STUDS 1/2'CDX SHEATHINIG 15' FELT 18" ~2 RED CEDAF~ PERFECTIONS (6" EXP) 2x4 PLATE BEYOND DOUBLE 2x4- PLATE 2x4-16' DC WALL STUDS 1/2' CDX SHEAIHItNO 15' FELT 18' #2 RED CEDA~R PERFECTIONS DAMP PROORNG B· P. C. FOUNDATI!ON WALL 2x4 KEY WAY 16' x 8' CONCRE'~t[ FOOTING 3'-0' BELOW fiNAL GRADE. (TYP.) OC - 2X4 OC -- R-1 EXISTING PROVIDE BLOCKING UNDER ALL BEARING EXISTING_ -- R-13 R-19 INSULATION -- L .... J PROVIDE 2x4.-32"oc. BENEATH REVERSE BEARING WALL) RIDGE 12 (3 7 2xB RAF'r~ER 2x8 HDR. SIMPSON HANGER R-30 INSULATION HURRICANE CUPS R-30 INSULATION FLUSH BEAM OC 4' PC SLAB R-19 INSULATION-- CROSS SECTION D R-13 INSULATION HURRICANE CUP~ PROVIDE {1) l~'x 11~ LVL FROM FRONT WALL TO REAR WALL, POS~ ON CENTER BEARING WALL AND FRONT AND RF.~R WALLS DOWN TO EDUNDAT]ON, HANG ALL CE L NO JOl~ WJ'I'H T~)P MOUNTED HANGERS' TO LVL SEAM. -- t" STEEk ROD -- 2x8 RIDGE -- 2x6 CBUNG JOIST INSULATION INSULATION R-19 INSULATION_ R'~119 INSULt)ION OU'~ RAFTER TO MATCH NEW 2xB RAFTERS HURRICANE CUPS 1" STEEL ROD 5-3/4"x 8'x ~./r ~;TEEL PLATE 1/2' nU.~T Y~:LD BEAM AND TIE ROD DETAIl Z~ 09-07-0t FLooR SYSTEMS 03-07-03 (3) PRO~ S~ACAS : ~ COFYRIOHT 2odd E~T ~D DnA~NG B {43 ~O~QE (3}'2~ ~, '~L FLO~ .Pg~S, AND ELEVAtiONS' ARE P~bTEc~E~' HOR. IN' CBUN~ ~8~ .UNDER FEDERAL C~]GHT LAW: (SED~.~OOE} ~ PLANS .HAY N~T BE ;EEPR~UcED WITH~T LL PLUS ~ND DESIGNS' ~E THE:SOLE, PROPER~Y ' EAST E~ DRAFTNG& bEsGN . THE RIGHT ~0 BUILD ONE% ONE STRUCTURE ' ,, PLANS IS LICENSED ~0 THE.BUYER. , 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE l~ F~.LT t/~"coX EXT. ~OOE,SH~TH~N0 ~ 6x6 TRUSS RAFTER , 8x8 BOXED POST NOlle: OMIT NEW F~ONT (EXISTING T(REMAIN) RAILS AS PER NYS, CODE sTEPS AS PER NYS, COOE CONC. FRONT PORCH 8' P. C, FOUNDAllON WALL 2x4 KEY WAY ~6" x ~ OONCRE'IE FOOLING 5'-0' BELOW FINAL GRADE. (TYP,) CROSS SECTION E OPTIONAL CEILING GRID LAYOUTS 25 Y~: ARCHITEC]URAL ORADE ROOF SHINGLE -- 15# FELT 1/2" CDX EX% ROOF SHEA1HtNo , , RIDGE V~NT -- 2x10 RIDGE 2x4.-32" oc--~ 18" ~2 RED CEDAR ~ERFEb'/ION~J BEDROOMS BEYOND DOUBLE 2x4 PLATE 2x4-16" Dc WALL STUDS 1/2" COX SHEA1~ING 15" FELT lB" #2 RED CEDAR PERFECTION$~ 2x4 PLATE BEYOND 2X4 DBL 2x10 FLOOR dST , ,~ L R-~,,tO INS~JLAT~ON ~NSULAltON · %"S" CDX S*~ PROVIDE BENEAI:H REVERSE RIDGE ATHG S)MpSON HANGER TRIP. ~B RAFTER '1~-30 INSULA'~ION (2) ~?;V',-"x FLUSH r BE~' EX,, 12~ TO L~,~. REAM. PROV1DE (1) l~'x 11~" LVL FROM FRONT WALL TO REAR WALL, POSTED ON CEN~IT:.R SEARING WALL AND ~ONT ~D REAR WA~S DO~ TO F~NDA~ON. HANG A~ CElUNG J~[~ ,~ T~ MOUN~O HANGERS 2x8 RIDOE -- 2~6 CEIUNG JOIST mDG~ VENT' .. H~RRiOANE cUPS r-'- INSULAS]ON HDGHT TO MATCH ' EXISTING FLOOR HEIGHT· R-30 -- (2) 1-5/4'x 9-1/2" LVL FLUSH SEAM. ' D}NING ROOM 5/B" nnx St)t) FLOO -- R-lC INSULA~ON 2" PC SLAB - DNdp pROOFING ~ P. C. FOUNDATION WALL 2x~. KEY WAY 16' ~ 8' CONCRETE FOO~NG 31-0" BELOW FINAL GRADE. ' CROSS SECTION, R-30 INSULAllON R-13 INSULATtON VERIFY NEW FOUNDA'~ON HEIGHT TO INSURE RNISH FLOOR HEIGHTS MATCH. RAFSERS ARE TO BE DSL. ON EACH SIDE OF OPENING AND A (2) 2x10 HEADER IS TO BE INSTALLEO AT TOP OF OPENING, 2x4 RAF]ERS ARE TO REST ' ON TOP OF ROOF ON lx12 PLATE.(PLATE TO BE CUT TO SHAPE OF ROOF·) NOTE: WERIFY ~IZE OF' EUPTICA~I. UNIT. ELIPTICAL RO!OF WINDOW ROOF TO BE ~EA~EO Wl'F~ (2) LAYERS OF 3/8"RENDING PLYWOOD (MGGLEBOARD) (GLUED AND SCREW) 1-3/4"x11-7/8" LVI_ GASLE END (CUT TO FIT GLASS UNIT) 2x4 SILL DETAIL 01-07-03 (I) RAI~ED CIEItJI'~G JO~STS (2) PRO~II~E RIDGEPOLES , (3) PROUDE S~ONG~ACKS (4.) PROVIDE (S) 2x8 FLUSH HDR. IN CEILING J~,ISTS~ (SECOND FLOOR) ~ ~) COPYRIGHT' 2000 EAST END DRAFTING A DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS NAY NOT BE REPRODUCED WITHOUT wRiTTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE ,THE SOLE PROPERTY OF EAST END DRAFTING &DESIGN. THE RIGHT TO BOILD ONLY 'ONE STRLIC~URE FROH :rHESE PI. ANS IS LICENSED TO THE'BUYER, VERIFY ALE, DIMENSIONS CONDITIONS 755_200i~ ' 03~09-01 CROSS SECTJONS 80f,9 NOTE, ALL MEASUREMENTS ARE TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCtiON. NOTE:INSURE NEW FLOOR HEIGHTS TO MATCH AJS 10 x 9Y~"-12"0c. FLOOR SYSTEM TOP OF EXIS~NG SECOND FLOOR SUBFLOOR TOP OF ERIS~NG SECOND FLOOR STAIR LAND~NG NOTE: ALL MEASUREMENTS ARE TO BE V~RIFIED IN FIELD PRIOR TO CONS~:~UCT~ON. TOP OF EX~S~NO SUBFLOOR TOP OF EXISTING -- HOUSE EOUNDA]]ON TOP OF NEW SUBFLOOR~-~ LVL HEADIER IN WALL I CCA SILL 3/4" CDX SUB FLOOR OR MATCH EXIS~NG TOP OF 8' PC, WALL TOP OF ANDERSEN BASEMENT UNIT (2820) SiLL OF ANDERSEN BASEMENT UNIT (2820) m ~AJS 10 x 11~"-16"oc. FLOOR SYSTEM ~ 12" ANCHOR ~ ~ 1/2" REBAR TOP MOUNTED JOIST HANGERS (2) l~"x 117~" LVL FLUSH GIRDER 5/8" REBAR 32' 1/2" REBAR 5" STEEL COLUMN "~ 1/2" REBAR NOTE: ALL MEASUREMENTS ARE TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. DAMP PROOFING B" P.C. FOUNDATION-`/// CELLAR //~ 4" P.C. SLAB le~x Bm CONC1 F~G. (MIN 5'-0" BELOW 2'-O"x 2'-O"x 1'-0" CONC, FTG. NEW FAMILY ROOM (2) 1~"x 117~" LVL FLUSH GIRDER 3" STEEL COLUMN TOP OF EXIS~NG SUBFLOOR S" P.C, FOUNDATION TOP OF EXIS~NG FOUNDADON TOP OF NEW SUBFLOOR TOP OF NEW FOUNDATION TOP OF FOUNDAI]ON SHELF NO~:ALL MEASUREMENTS m ARE TO SE Vt[RIFlED IN FIELD PRIOR TO CONSTRUCTION. EXIS~NG CELLAR FLOOR NEW CELLAR FLOOR 09-07-01 (1) NEW DETAILED SECTION OF FOUNDATION AND FAMILY ROOM ~EING CHANGED (~COPYRtGHT 2000 EAST END DRAFTING ~ DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS 755-200t 09,'07-01 F = I'~0" DETAIL WALL SECT,ION' 9 of' 9 PROVIDE ANTI4CALD MD/OR THERMAL SHOCK MIt'VENTING DEVICES AS 10 PAiL N.Y. STATE BglWING CODL PROVIDE OPENINGS FOR EMERGENCY ESCAPE AS REQUIRED BY PART. 714 OF PROVIDE ~ HR. FIRE RATED SEPARATION TO PART. 717.3 (~ (~-1 OF N.Y. STATE BUILDING CODE. PLUMBING ~ PLUMBING ~ · ~ UNES NEED IEmltm BEr~ COVEfllN~ If copper tubing ia used for water distributing system; piping shall be of types K or L only UHD~I~ CERTIfiCATE REQUIRED PLUMBER CERTIFICATION N.Y. STATE BUILDIN~ CODE. ON LEAD CONTENT BEFORE ~ "APPROVEO AS NOTEDL~5~~' CERTIFICATE C 'OATE: ~/~f,~' ".,~# ~ SOL~ER USED/N WATER FEE: ~ g?-~ 86. ~ SUPPLYS~TEM ~NNOT N~n BU~COm~ DEPA~NT AT EXCEED 2/~O of I% ~AD. ?~s4802 ~ ~ m 4 PU FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POUREO CONCRETE 2. ROUGH -, FRAMING & pLUMBING t. FINAL - CONETRUC'rlON MUST BE COMPLETE FOR C,O. - ! LL CONSTRUCTION SHALl- MEET 'IR REQUIREMENTS OF THE N.Y, ATE CONSTRUCTION & ENERGY /DES, HOT RESPONSIBLE FOR ~SlGN OR CONSTRUCTION ERROR':: OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY FRONT ELEVATION LEFT ELEVATION BUILDING CONSTRUCTION NOTES: 3. IJeeel4mTi~dM'(Wil~n~) dadlb4~jamM,~a,m--~T~aimaJ,t~.~d~mMm~ea~lS-mm~lmm. AJ~mmlE~ 4. SlatnMbd~lbJ~'wfl~...L.L..,~,2'.~'cair. ~ GENERAL NOTES: ~ COPYRIGHT 2000 EAST END DRAFTING & DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS HAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FRO~ THESE PLANS fS LICENSED TO THE BUYER. NOTE: ~ VERIFY ALL DIHENSIONS AND CONDITIONS 755-2001 °~" ~ BDK OAT[ 03-09-01 SC^L~ I/&" : I'-0" ~H£ET TITL[ ELEVATIONS l of 8 BE] REAR ELEVATION RIGHT ELEVATION k (~ COPYRIGHT Z000 EAST END DRAFTING & DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. ~ O NOTE: VERIFY ALL DIHENSIONS AND CONDITIONS 755-2001 ~"~'" ~'BDK t~^~ 05-09-01 Il&" = I'-O" ELEVATIONS 2of8 B9'-9~° L ___J , L .... J FURNACE AREA ~ ~ n 4 PC, SLAB ~' ~1 I .... ~L,- ........ n NOTE. iNSURE FINtSH FLOOR mm gRAWL SPACE ~ m,CRAWL SPACE: ] ~ ~ Z" PC SLA .~__ m J L ............................ 6"x 6" BOXED COLUMN ON 12" SONA TUBES ON 2'-O'x2'-O"x 1'-0' CONC FOOT~NOS (MIN 3'-O' BELOW FINAL GRADE.) {0' "0' :0' FOUNDATION PLAN PROVIDE MIN, R-lg INSULATION BETWEEN FLOORS, I~j_~OPYRIGHT Z000 EAST END DRAFTING & DESIGN FLOOR PLANS AND ELEVATIONS ARE PROTECTED t.~4DER FEDERAL COPYRIGHT LAW. Pt. ANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF FAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS 755-2001 ~w. ~: BDK CHECKED BY DATE' 03-09-01 SC,CE I/Z," = I'-0" FOUNDATION PLAN 3of8 8"x 8" BOXED X ....... _5 ....... _~ ............. .......... AW251v . AW25ilv ,AW251V . Bx6 TRUI NOTE, ALL FLOOR JOISTS ARE TO EXISTING FLOOR JOISTS, BE RIPPED DOWN TO MATCH NOT~;ADJUST SIDING TO INSHRE F~I~'ST COARSE TO REMAIN AT SAME HEIGHT AROUND HOUSE,(VERIFY POfNTS ON HOUSE WHERE TRANSIT{ON OF SIDING HEIGHT IS TO TAKE PLACE,) NEw STAIRWELL 6068 POC DOOR .BATH NEW FAM L:-- OOM 'T' NEW .~-~A~L~ lO x 11-7/8" - 16 Dc 0 T-11-5f~" CEILING JOtS;TS z[ CONSTRUCTION JCONSTRUCTION FOYER KITCHEN 'f MUD ROOM 1846 1B46 PROVIDE HANDRAIL AS PER NY$ CODE, 2446 2442 2446 LIVING ROOM, DINETTE, AREA I SM ,o FWG60611 FWGS3611S EXISTING LIBRARY CATHEORAL NEW DINING RQQM 2446 5" 2446 6"x 6" BOXED COLUMN [] (_3'~ 2x8 C;CA GIRDER [] LINE OF BALCONY ABOVE. FXISTING CONCRETE PATIO PROVIDE HANDRAIL AS PER NYS CODE. PROVIDE HANDRAIL AS PER N¥S CODE FIRST FLOOR ALL EXTERIOR WALLS ARE TO BE INSULATED WITH R-13 INSULATION. PROVIDE R-SO INSULATION BETWEEN FLOORS. ALL INTERIOR WALLS ARE TO BE INSULATED WITH R-11 INSULA~ON. PLAN NOTE:ADJUST SIDING TO INSURE/ FIRST COARSE TO REMAIN AT SAME HEIGHT AROUND HOUSE, ALL PLUMBING STACK VENTS ARE TO BE ON ~HE BACK SIDE OF THE HOUSE. PAINT TO MATCH ROOFING MATERIAL. (~) COPYRIGHT ZOO0 EAST END D~TING · DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS FlAY NOT BE REPRODUCED INITHOUT WRITTEN AUTHORIZATiON. ALL PLANS ANO DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FRO~I THESE PLANS IS LICENSED TO THE BUYER, 0 0 NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS ~ROJECT NO 755-2001 ~" ~ BDK 05-09-01 IJ~''1 = I'-0" FIRST FLOOR PLAN 4of8 '~1 ~ HALL HAUL ~ MASTER BATH BEDROOM BATH :, "'?".r~' ""'¢ ................................................. i" 1 NEW ! i ' : MASTER BEDROOM ~ TRAY CEILING ~ ~r 2xB-16 cc HUNG FROM RIDGE O 9'-7 1 6'"T'"'""' "'~k'~!"O' ............... ~ ................................... '""' /'~' L~, 1s,-~o' , UPpeR DECK b/4 x 6 DECKING 2042 2442 r~- 2442 CL_~ __ :THIS WALL W~LL BE WALL(TO ALLOW FOR SHORTER THAN OUTER FASCIA TO LINE UP, PROVIDE HANDRAILS AS PER NY$ CODE. SECOND FLOOR PLAN ALL EXTERIOR WALLS ARE TO BE iNSULATED WITH R-15 INSULATION, PROVIDE R-30 INSULATION BETWEEN FLOORS, ALL iNTERIOR WALLS ARE TO BE INSULATED ~TH R-11 INSULATION, FESStB~¢ NOTE: ALL PLUMBING STACK VENTS ARE TO BE ON THE BACK SlOE OF THE HOUSE. PAINT TO MATCH ROOFING MATERIAL. © COPYRIGHT Z000 EAST END DRAFTING & DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AN~ DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. 0 NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS 755-Z001 CHECKED BY O*TE 05-09-01 SCALE I//~" = I'-0" SHEET TELE: SECOND FLOOR PLAN NO- 5of8 ~- ]---~ r iI DORMER WALL TO BE BUILT II .~ 2x8 RAFTER 6" oc I (3) 2xlO RAFTERS I III L.'~ ------. RAFTERS- L -- --~i I I ~2x8 RAFTERS-lB" ,' ' 2x12 RIDGE JL ....... I ~ [ 2x8 RIDGE IIII DORMER WALL TO BE BUILT] J II II /~' ....... II ROOF PLAN ~) COPYRIGHT ;~000 EAST END DRAFTING E DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN, THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER, 0 0 NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS 755-2001 D~.. ~BDK ~rE 05-09-0l II&" = I'-0" TITLE ROOF PLAN 6of8 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE 15~ FELT 1/2" COX EXT, ROOF SHEATHING 12 RIDGE VENT 2x10 RIDGE 7 FASCIA 18 VENTED DOUBLE 2: 2x5 / 2X4 CK SOFFIT (SEE OETAIL) J -~0 R-30 INSULATION 2x4-16" DC WALL STUDS N~W 1/2" CDX IEATHING BEDROOM ~ MASTER BATHROOM J MASTER BEDROOM R-lB INSULATION / RIPPED TO MATCH UNDER ALL PARALLEL WALLS )FFIT (SEE DETAIL) IIII / H -30 2)1-5/4"x H-7/8" LVL IFLUSH BM ~R-30 P CEDAR PERFECTIONS (6" EXP) ~ ~ATH IIi I kT NECESSARyURR HALL ii FA~IlY ROOM E [[ 5/8" COX SUB FLO~ '' iR MATC. 15" FELT 18" #2 RED 2x4 PLATE 3-1/2" DOUBLE 1/2" C[ 15" FELT 18" #2 REC 2x4 PLATE DAMP PROC 2×4 KEY 16" x 8" CONCRETE FOOTING 5'-0" BELOW FINAL GRADE (TYP,) INSULATION NEW STAIRS ON 8"x16" CMU PIER ON 2'-O"x (E) 1-3/4" x 9-1/2" LVL GIRDER R-19 INSULATION 2X4 BACK ;ULATION CROSS SECTION A 25 YR ARCHITECTURAL GRADE ROOF SHINGLE 15~ FELT 1/2" CDX EXT. ROOF SHEATHING 2x6-16" DC RAFTERS RIDGE VENT 2xB RIDGE HURRICANE FASCIA 18 VENTEG SOFFIT (SEE DETAil) DOUBLE 2xA PLATE 2x4-16" Dc WALL STUDS-- 1/2" COX SHEATHING 15" FELT 18" ~2 RED CEDAR PERFECTIONS (6" 2x¢ PLATE 12 R-30 INSULATION t I INSULATION II NEW II DINING ROOM VERIFY NEW FLOOR HEIGHT TO MATCH EXISTING FLOOR HEIGHT. CLIPS 2x6 SOFFIT R-13 INSULATION NOTE: VERIFY NEW FOUINDATION HEIGHT TO INSURIE FINISH FLOOR HEIGHTS HATCH. 25 YR, ARCHITECTURAL GRADE ROOF SHINGLE 15~ FELT 1/2" CDX EXT. ROOF SHEATHING 2x8-16" DC RAFTERS FASCIA lB VENTED SOFFIT (SEE DETAIL) DOUBLE 2x4 PLATE 2x4-16" DC WALL STUDS 1/2"CDX SHEATHING 15" FELT · 18" #2 RED CEDAR PERFECTIONS (6" E×P) · 2x4 PLATE BEYOND DOUBLE 2x4 PLATE 2x4-16' DC WALL STUDS 1/2" CDX SHEATHING 15" FELT lB" #2 RED CEDAR PERFECTIONS (6" FAMILY ROOM BEYOND 2x4 PLATE CAMP PROOFING 8" P C FOUNDATION WALL 2x4 KEY WAY 16" x B' CONCRETE FOOTING 3'-O" BELOW FINAL GRADE, (TYP) R-19 ~NSULATION -- / CROSS SECTION C DAMP PROOFING 8" P, C, FOUNDATION WALL 2x4 KEY WAY 16" x 8" CONCRETE FOOTING 3'-0" BELOW FINAL GRADE. (TYP.) RIDGE VENT 2x10 RIDGE A~I¢ / 2X4 STRONG BACK -- 2x8-16" oc EXISTING BEDROOM EXtSTING FOYER : R-19 INSULATION EXISTING BASEMENT L .... J 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE 15~ FELT 1/2" CDX EXT ROOF SHEATHING 2x8-16" DC RAFTERS HURRICANE CLIPS FASCIA lB VENTED SOFFIT (SEE GETA~L) DOUBLE 2x4 PLATE 2×4-16" Dc WALL STUDS 1/2" COX SHEATHING 15" ~LT 18" #2 RED CEDAR PERFECTIONS (6" EXP) - 2x4 PLATE RIDGE VENT 2x10 RIDGE ~ 12 R-3o INSULATION -- R-15 INSULATION ATTIC R-30 INSULATION MASTER BEDROOM TRAY CEILING ~"~/- R-.t0 J INSULATION 5/8' CDX SUE FLOOR · OR MATCH EXISTING 2x4-32" DC 2x6 / 2X4 STRONG BACK HURRICANE CLIPS INSULATION AJS 10 x 16" DC DOUBLE 2x4 PLATE 2×4-16" Dc WALL STUDS 1/2" CDX SHEATHING 15" FELT 18" ~2 RED CEDAR PERFECTIONS (6" Zx4 PLATE R-30 INSULATION FAMILY ROOM INSULATION 5/8" CDX ~UB FLOg -- R-13 INSULATION DAMP PROOFING B" P C FOUNDATION WALL- 2x4 KEY WAY 16' x 8" CONCRETE FOOTING 3'-0" BELOW FINAL GRADE, (TYP) R-19 INSULATION ON 8"x16~ CMU PIER ON 2'-O"x CROSS SECTION B 12 -- (3) 2xlO RAFTER HDR. RIDGE VENT -- ~ HURRICANE CLIPS INSULATION EXISTING 5/5" COX SUB OR MATCH EXIS~NG 2xB RIDGE 2×6 CBILING JOIST (2) 1-3/4"x 9~1/2" LVL FLUSH BEAM R-13 INSULATION HURRICANE CLIPS INSULATION TO MATCH NEW 2x8 RAFTERS RM9 INSULATION HURRICANE CLIPS INSULATION EXISTING LIVING ROOM NEW (2) 1-3/4% 9-1/2" SEMI-FLUSH BEAM W/Il) 3/4" STEEL FLITCH PLATE, INSULATION F. XISTING LIBRARY -- R-13 INSULATION 4' PC 5LAB 5/8" CDX OR MATCH EX 5:#NG EXISTING PACE R-19 ILNSULATION -- L .... J L .... J CROSS SECTION D ~) COPYRIGHT 2000 EAST END DRAFTING & DESIGN ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTEO UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ON~ STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. C5 I 0 Q_ NOTE: VERIFY ALL DIHENSIONS AND CONDITIONS 755-2001 D,.....,,. BDK CHECKED I~Y ~Te 05-09-01 Il&": I'-0" CROSS SECTIONS 7of8 25 YR. ARCHITECTURAL GRADE ROOF SHINGLE 15# FELT 1/2" CDX EXT, ROOF SHEATHING 2x6 T&G DECKING 6x6 TRUSS RAFTER Bx8 BOXED POST STEPS AS PER NYS. CODE 8" P. C. FOUNDATION WALL 2x4 KEY WAY 15" × B" CONCRETE FOOTING 5'-O" BELOW FINAL GRADE 25 Yr. ARCHITECTURAL GRADE ROOF SHINGLE 15~ FELT t/2" CDX EXT ROOF SHEATHING 2×8-16" DC RAFTERS 6" FASCIA 18 VENTED SOFFIT (SEE DETAIL) J DOUBLE 2x4 PLATE 2x4-1B' cc WALL STUDS 1/2" COX SHEATHING 18" ~2 RED CEDAR PERFECTIONS (6" EXP) - 2x4 PLATE BEYOND DOUBLE 2x4 PLATE 2x4-16" DC WALL STUDS 1/2" CDX SHEATHING 15" FELT lB" ~2 RED CEDAR PERFECTIONS I 2x4 PLATE FAMILY ROOM BEYOND DAMP PROOFING B" P C FOUNDATION WALL 2x4 KEY WAY 16" x B" CONCRETE FOOTING `S'-O" BELOW FINAL GRADE (TYP.) RAILS AS PER NYS, CODE CONC FRONT PORCH CROSS SECTION E RIDGE VENT 12 2×10 RIDGE ~ / 2X4 STRONG BACK R-13 INSULATION EXISTING BATHROOM DBL 2x10 INSULATION EXISTING KITCHEN INSULATION ATTIC D~L. 2x8 JOIST HDR. 2xlO RAFTER HDR RIDGE VENT R-50 HURRICANE INSULATION {'~XISTING BEDROOM OR MATCH EXISTING DC R-,SO INSULATI VERIFY NEW FLOOR N~W HEIGHT TO MATCH HEIGHT, DINETTE EXISTING FLOOR 2x8 RIDGE 2x6 CEIUNG JOIST -- (2) 1-5/4"x 9-1/2" LVL FLUSH BEAM. RIDGE VE -- R-13 INSULATION HURRICANE CLIPS -- R-13 iNSULATION -- (2) 1-5/4'x 9~1/2TM LVL FLUSH BEAM. NEW pINING ROOM 5/8" CDX SUB FLOC OR MATCH EXIS?ING 5/8" COX SUB FLOOR ~-19 INSULATION 5/8" FDX SUB OR MATCH EXIS~NG 10 x NEW CRAWL SPACE R-19 INSULATION -- 2" PC SLAB ~ CROSS SECTION F R-30 INSULATION INSULATION NOTE, VERIFY NEW FOUNDATION HEIGHT TO INSURE FINISH FLOOR HEIGBTS MATCH. OPTIONAL CEILING GRID LAYOUTS RAFTERS ARE TO BE DBL. ON EACH SIDE OF OPENING AND A (2) 2x10 HEADER IS TO BE INSTALLED AT TOP OF OPENING. 2x4 RAFTERS ARE TO REST ON TOP OF ROOF ON lx12 PLATE,(PLATE TO BE CUT TO SHAPE OF ROOF.) -- ROOF TO BE SHEATHED WITH (2) LAYERS OF 3/S"BENDING PLYWOOD (WIGGLEBOARD) (GLUED AND SCREWEO) 1-3/4"x11-7/8" LVL GABLE END (CUT TO FIT GLASS UNIT) NOTE:: VERIFY SIZE OF ELJPTICAL UNIT ELIPTICAL RtOOF WINDOW DETAIL 032254-1 ~FESStO~¢ ~;) COPYRIGHT 2000 EAST END DRAFTING & 0ESIGN ~ FLOOR :PLANS AN{) ELFVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODU~ED WITHOUT WRITTEN AUTHORIZATION. ALL PLANS ~ DESIGNS ARE THE SOLE PROPERTY OF EAST END DRAFTING & DESIGN. THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED TO THE BUYER. NOTE: VERIFY ALL DIMENSIONS AND CONDITIONS PROJECT NO. 755-~001 ""~"" ~ BDK 05-09-01 I/&" = I'-0" CROSS SECTIONS 80£8