Loading...
HomeMy WebLinkAbout34535-ZTown of Southold Annex 54375 Main Road Southold, New York 11971 1/27/2012 CERTIFICATE OF OCCUPANCY No: 35416 Date: 1/27/2012 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: ADDITION/ALTERATION Ocean View Avenue, Fishers Island, Sec/Block/Lot: 9.-11-7.12 Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 3/6/2009 pursuant to which Building Permit No. 34535 dated 3/26/2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and additions, incluc[mg sprinkler system, to an existing one family dwelling as applied for. The certificate is issued to Highland House FI LLC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 9/29/10 R10-09-0005 11/8/10 34535 10/14/10  Glenn Gallo .- FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall' Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34535 Z Date MARCH 26, 2009 Permission is hereby granted to: HIGHLAND HOUSE FI LLC OCEAN-VIEW AVE FISHERS IS,NY 06389 for : ALTERATIONS & ADDITIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at County Tax Map No. 473889 Section 009 pursuant to application dated MARCH Building Inspector to expire on SEPTEMBER 26, OCEAN VIEW AVE FISHERS ISLAND Block 0011 Lot NO. 007.012 6, 2009 and approved by the 2010. Fee $ 2,205.20 Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLI) BUII,DING DEPARTMENT TOWN ttAI,L 765-1802 APPLICATION FOIl CERTIFICATIC. OF OC(lYI'AN This applicalion must be filled in by typewriter or ink and submitted to the Building 1)¢ BLDG. DEPI. rtmcnt w i t P,'~'lh ~ Sf'~,~ ~[ ~[0kl~g· A. For new huilding or new use: 1. Final survey of' prope~y with accurate location of all buildings, pt'openly lines, streets and uuusual natural or topographic features. 2. Final Approval fi'om Health Dept. of water supply and sewerage-disposal (S-9 lbrm) 3. Approval of electrical installation from Board of Fire Undep4, riters. 4. Sworn statement from plumber ce~Xifying that the solder used in syslcm contains tess than 2/10 of 1% lead. 5. Commercial building, industr/al building, nmltiple residences and similar buildings and installations, a certificate of Code Compliance frorn architect or engineer responsible for the building. 6. Subnfit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforlning uses, or buildings and "pre-existing" laud uses: 1.Accurate sup, cy of properly showing all property lines, streets, building and anusttal lmtural or topographic features. 2. A properly completed application and consent to inspect signed by thc applicant Ifa ( mlificatc of()ccupancy is denied, thc Building Inspector shall state thc reasons therefor in writing to the applicant. C. Fees ~ ~'~ 1. Ccaificate of Occupancy - New dwelling $25.00, Additinns to dwelling $2500. Alterations to d~etlin~ Swinmfing pool $25.00, Accesso~ building $25.00, Additions to accessory building $2500, Businesses $50.00. 2 Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Ce~lificateofOccupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. 'I'empo~aiy (/cttificate of()ccupancy - Residential $15.00, ComnKucial $1500 New Constmclion: Old or Pre-existing Building: / (check one) Subdi~. isi,m Til~xn 1 lall :~.llllCX .5 I;17,5 Main l/,,ad l'.(). Box I Telcl>honc (631) 765-1802 Fax (631) 76,~-9502 ro.qer, richert~,town.so uthold ,ny.us BUIIJ)IN(; I)EPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ssued To: Peter & Susan Lawrence ~,ddress: 27 Ocean ViewAve City: Fishers Island St: NY Zip: 639£ Building Permit #: 34535 Section: 9 Block: 11 Lot: 7.1,; WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Sontractor: DBA: Z&S Contracting Inc LicenseNo: 4798-me SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Servicelph ~ Heat ~ DuplecRecpt ~ Service 3 ph Hot Water GFCl Recpt Main Panel A/C Condenser Single Recpt Sub Panel A/C Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment; 7-exhaust fans Ceiling Fixtures ~ HID Fixtures Wall Fixtures ~.~ Smoke Detectors Recessed Fixtures ~ CO Detectors Fluorescent Fixture ~.~ Pumps Emergency Fixtures~ Time Clocks Exit Fixtures U TVSS Notes: Inspector Signature: Date: Oct 14 2010 81-Cert Electrical Compliance Form TOWN OF SOUTHOLD OFFICE OF BUILDING INSPECTOR P.O. BOX728 TOWN HALL SOUTHOLD, N.Y. i 1971 TEL. 765-1802 C E R T I F I C A'.T i O N Building Permit NO. Owner ~ 4please print) Plumber (please print) Date / / I certify that the solder used in the water supply system con%ains l~ss than 2/10 of 1% lead~ (plumber's signature) Swor~ to before me this .Notary'Public~qj ~_,County OCT, 3'L L~IO FIELD INSPECTION REPORT DATE COMMENTS . �ro FOUNDATION(1ST) �y -------------------------------- FOUNDATION(2ND) �u z 0 ROUGH FRAMING& PLUMBING / I \ INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS z m C �t y O C z '\fix I y fv y TO¥CN O;F SOUTHOLD BUILDING DEPARTMENT TOWN ItALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork. net Examined . Approved ~/~, 20 Disapproved a/c Expiration PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: · Building Inspector a. TI sets of plans b. PI tis apl~lication MUST be completely accurate plotalP~h§~lcale. Fee accr at plan ~h~20~ [n~31t~l~ll~f Iht anclr ATION FOR BUILDING PERMIT Date 1,4t~--~,,q ~"Pd-. ,2009 INSTRUCTIONS qlled in by typewriter or in ink and submitted to the Building Inspector with 4 'ding to schedule. 'buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. fi Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~ ~ ' (Signature of applicant or nagae, ifa corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~t C--r~qC.AI~D 4'qOg~g ~- I t I.LC . (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section '~ Block ~ [ Lot ~ · t~ Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~ I,,1G~-~ ~ ~ C.'~' 1>~ t..-~OxaO b. Intended use and occupancy_ 3. Nature of work (check which applicable): New Building. Repair Removal Demolition 4. ©OO Fee 5. t Addition Alteration Estimated Cost ~t~ I ~ ~O ~ If dwelling, number of dwelling units If garage, number of cars Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front '~O} Rear '~©} .Depth Height '~5 ~ Number of Stories Dimensions of same structure with alterations or additions: Front ':~o~ Rear Depth ~ Height '~,~5 ~ Number of Stories 8. Dimensions of entire new construction: Front Rear Height Number of Stories 9. Size of lot: Front ~:~ Rear ~'~ Depth _Depth 10. Date of Purchase '~O~.Yl C'/)'2o2~ Name of Former Owner ll. Zone or use district in which premises are situated i~.- ESO ~-~'5~C~',~T~-- COV~ I~I'a~X'I' 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO v/ 13. Will lot be re-graded? YES NO__Will excess fill be removed from premises? YES NO 14. Names of Owner of premises ~ j L,~,,C-- Addressh'~lv~o~; Phone No. Name ofArchitect 'I~R. OC,~ ~. ~N~N Address~ow.:~Sm-'~x ~q'q~'qPhoneNo('~2) Name of Contractor 'r' ~ l) Address loom Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO ~ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF~,a~o 'ffo~r,) ~ ~ D ' t~t,q L.,I,l',.l being duly sworn, deposes and says that (s)he is tbe applicant (Name of individual signing contract) above named, (S)He is the ,or~.C.,.~i ~T~;-~- (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to bead'?ne this z ~day, of /f~r'~ o 20ff~ N~a~ Public, State~f N~ No. 01 EN5045343 Qualified In N~sau Cou~ ~ I COMMISSION ~pires July 15, 20 ~ Signature of Applicant ",ToW.n, of ' Southold,. ' - Erosion, Sedimentation & Storm.water Run-off A8sE$$MEN? FORM PROpeRTY L~m~. ~.C:.T.M.~ .. 11~E FOL1.OlflN, G AC;TIOH~ MAy REQUIRE THE ~.,.u,e~../O ' - 2 3 4 5 6 D~es the Site PlUm andkw Suwe~ ~ All Prolx~ed Dm~ ~ I~ ~ & L~? lam ~all.~ au ~ G~ ChM~ ~ ~ ~l $~ W~ ~g ~e I~ ~ ~ ~ ~Y~ ~ ~n any pa~ · ~ a Na~l Wa~t ~ ~ ~ ~ S~? · i~ PmJ~ ~ln ~e T~t~ Ju~ ~ ~ln O~e Hued (1~) ~et el a we~a~ ~ Beth? Hu~ (100') of H~I ~? 7 8 Wlll D~iveweys, Parking Area~ or ~her Imoewim~s ~;utface~ b~ Sloped to Direct S~orm-wa~er Ru.-OfT into andlor ~ the direction cfa 'i'own d~ht-~f-way? Will tiffs Protect Require the Pla~:eh~nt el Mate~el; R~Wal of V~getaUo~ end/~x ~e ~ of any I~m WEh~ ~e T~ ~ght~f-Way~R~ ~d~? ~hls Kern fill N~ Inclu~ the I~ll~on ~ D~eway ~mns ) 9 Wi~ ~ Pr~t R~ulm Site Preparation ~in ~ O~ Hund~ (1 ~) Ye~ F~ain of any Wat~? ~ [2]_ _,/ E~EMPTION~ Dees thlSlpmje,~ meet Ihe minimum etandards fo~ ~lassll~ce~ as an Agrieulk~al Pro~ STATE OF NEW ~er ~or mp~v~ of ~e ~cr of ~e~s, ~d is duly au~ofiz~ m ~ffon. or ha~ pe~o~ed ~e s~d ~ ~d to ~t ~e ~rk ~1 ~ ~rfo~cd in ~e m~er set fo~ in the appllcaaon filed hem~ ................... .................. Nomu Pub c: ...... ~.~ ..... .......... FORM - 06~07 SUF F 0 L K't'~ BUREAU of ELECTRICAL INSPECTORS. REQUEST FOR INSPECTION FAX FORM REQUESTED BY Suffolk Bureau of Electrical Inspectors, Inc. 40 Nottingham Dr., Middle Island, NY 11953 Telephone: 1 631 495 8136 Fax: 1 631 980 6455 Emaih SBEIGS@gmail.com Company Name: Name: License No.: Add ress: Phone Number: 30BSITE INFORMATION (* indicates required information) *Name: *Ad dress: *Cross Street: *Phone: Permit No.: Hagstrom map: Tax map District: Section: ~ Block: II Lot: r~. ~ ~ *BRIEF DESCRIPTION OF WORK (Please Print Cl~orly) ~y ~ ~ I )~ ~ ~nL~ ~'~ (Please Circle All That Apply) *Is job ready for inspection: *Do you need a Temp Certificate: Temp Tnformation (if neededl: Size: ~ 3Phase Yes/(~ ~/ No 100 150 200 300 *~-"'~w Se~ Re-connect Number of Meters *Fax Temp to LIPA ~ Temp to Contractor_~ Additional Information: Rough In Final 350 (~ Other: Change of Service Overhead I OCT'8 2010 [UL~ BLDG. DEPi. TOWN OF SOUTHOt" 'OWNER ~O~MER OWNER,~ ' ' /~ L._...~ RES.' .~..~ SF. AS. LAND IMP. OF $OUTHOLD STREET S FARM DATE VL. TOTAL AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre Value Per Value Ac re PROPERTY RECORD CARD V l LLAGE DIST. SUB. LOT ACR. ~yp'!l: OF BUILDING COMM. CB. MICS. Mkt. Value Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH BULKHEAD Hou~e.~Plot ~ '~. Total DOCK COLOR TRIM Extension Extension Extension Porch Porch Patio Total ~ndation Ext. Walls Place Roof Recreation Room Bath Floors Interior Finish Heat Rooms l~t Floor Rooms 2nd Floor Driveway inette BR. OW~NER STREET VILLAGE DIS'r. SUB. LOT FORMER OWNER N ELi~'' ACR. S W CODE DATE OF CONSTRUCTION LAN D IMP. TOTAL DATE REMARKS Tillabl~ FRONTAGE ON WATER W~land FRONTAGE ON RO~ Meedowl~d DE~H H~ [!ot BULKH~D ~tel M. Bldg. Foundation Bath Extension Basement FIoors Extension Ext. Walls Interior Fin ish Extension .. Fire Place Heat Porch Pool Attic Deck Patio Rooms 1st Floor Breezeway Driveway Rooms 2nd Floor Garage Bldg. COLOR TRIM Kinlin Rutherfurd Architects 330 West 38" Street, Suite 1006 New York, NY 10018 212.6952988 775.582 i736 March 6, 2009 Michael J. Verity Building Department Town Hall 53095 Main Road $outhold, NY, 11971 Dear Michael, We are please to submit this application for the Highland House, on Fishers Island, NY. Enclosed for your revision are 4 sets of drawings, i stamped and approved plan for the Main House Septic System by the Suffolk County Department of Health Services and also a blank check to cover the required fees. If you have any questions, or need any additional information, please don't hesitate to give me a call. Sincerely, Bruce D. Kinlin, AIA www.kinlinrutherfurd.com Page 1 of i Kinlin Rutherfurd Architects 330 West 38t~ Street, 10t~ Floor New York. NY 10018 212.695.2988 March 19, 2009 Pat Conklin Town of Southold Building Department 53095 Main Road Southold, NY, 11971 Dear Pat, Enclosed is documentation for the Lawrence house renovation project at Fishers Island that you are currently reviewing. We have completed a "res-check" for the house. All of the specifications from the insulation company and for the new triangle tube high efficiency boiler that we will be using are attached as well. The replacement windows will be Low E and argon filled as well. I am really pleased that we will be 18% above current ener~ code requirements. The review is for the entire house, and it includes the "sunroom". The windows there will be Iow E argon gas filled as well. We are also putting in a new crawlspace exterior wall that is highly insulated. An enclosed drawing addresses the rain water retention system we will employ. There will be 5 drywells located around the house. The calculations and specifications are on the drawing. Also attached is a drawing showing the strapping system that will be used for the new window installation. Finally, for the "sunroom, where we are rebuilding that glass wall, we will be using an approved hurricane protection shutter system. The specification for that system is enclosed as well. I think these items address all the issues you brought up with me the other day on the phone. If there are any other issues, please give me a call. Thanks for your help with this review. Sincerely, Bruce D. Kinlin, AIA www. kinlinruther~urd.com Page 1 of 1 Kinlin Rutherfurd Architects 330 West 38t~ Street, Suite 1006 New York. NY 10018 212695.2988 775.582.1736 fax July 27, 2009 Robert Fisher Fire Safety Inspector Building Department Town Hall 53095 Main Road Southold, NY, 11971 Dear Bob, Enclosed for your review are 3 sets of drawings showing the sprinkler system to be installed at the Highland House, on Fishers Island, NY (permit # 34535 Z). If you have any questions, or need any additional information, please don't hesitate to give me a call. Sincerely, Bruce D. Kinlin, AIA JUL I! BLDG. DEPT. TOWN OF SOUTHOLO www.kinlinrutherfurd.com Page 1 of i Kinlin Rutherfurd Architects 330 West 38~' Street, Suite 1006 New York, NY 10018 212.695.2988 775.582.1736 fax November 6, 2009 Mr. Gary Fish Town of Southold Building Department Town Hall 53095 Main Road Southold, NY, 11971 gO¥ 1 6 BLDG. DEPT. 10~t OF SOUTHOt~ Dear Gary, Please see the attached drawings regarding the renovation of the Highland House. As per your request, these drawings illustrate the exact location of the new foundation walls. Close inspection of the existing conditions in that location determined that the framing and foundation walls were rotted. It was necessary to rebuild the foundation and framing in the specified area. Thank you, Br~ce D. Kinlin, AIA www.kinlinrutherfurd.com Page 1 of 1 September 13, 2010 Pat Conklin Southold Building Department Town Hall Annex Building 54375 Route 25 P. O. Box 1179 Southold, NY 11971 (631) 765 - 1802 Dear Pat, This letter is to request a six-month permit extension for the Highland House FI LLC, located on Oceanview Ave. Fishers Island, NY. The permit number is 34535 with expiration date: 09-26-2010. Please call our office, or send a response to confirm you have received our request. flavia@kinlinruther~urd.com 8LE)g LUCINOA J ~.. DRAINAGE CALCULATIONS ROOF AREA = 3272 9F REQUIRED = 3272 X 2/12 = 545 CF 545 CF / 28.26 CF,~ = 19.28 VF USE FiVE (5) - 6'0 X 4' DEEP DRY Wm~ PROVrDDE DRY WELL FOR ROOF DRAINAGE (5) SEE DETAIL '\ HIGHLAND HOUSE DRY WELL LOCATION PLAN A021 REScheck Software Version 4.2.1 Compliance Certificate Project Title: Highland House Energy Code: 2007 New York Energy Conservation Location: Construction Type: Heating Type: Glazing Area Percentage: Heating Degree Days: Construction Site: Ocean View Ave. & Heathulie Ave. Fishers Isrand, NY Construction Code Suffolk County, New York Detached I or 2 Family Non-Electric 20% 5750 Owner/Agent: Compliance: 18.6% Better Than Code Maximum UA: 1033 Your UA: 841 Designer/Contractor: Bruce Kinlin Kinlin Ruthedurd Architects, PLLC. 330 W 38th St. Suite 1006 New York, NY 10018 212-695-2988 bruce@kinlinrutherfu rd .com Roof/Ceiling 2nd & 3rd Floor: Cathedral Ceiling (no attic) 2977 49.2 0.0 63 North Wall 1st Floor: Wood Frame, 24" o .c. 266 18.2 0.0 12 Window 101: Wood Frame:Double Pane 8 0.310 2 Window 137: Wood Frame:Double Pane 10 0.310 3 Door E101: Solid 23 0.320 7 Door E102: Solid 19 0.320 6 North Wall 2nd & 3rd Floor: Wood Frame, 24" o .c. 487 18.2 0.0 25 Window 201: Wood Frame:Double Pane 12 0.310 4 Window 202: Wood Frame:Double Pane 12 0.310 4 Window 203: Wood Frame:Double Pane 12 0.310 4 Window 204: Wood Frame:Double Pane 12 0.310 4 Window 301: Wood Frame:Double Pane 9 0.310 3 Window 302: Wood Frame:Doubte Pane 9 0.310 3 Window 206: Wood Frame:Double Pane 7 0.310 2 West Wall 1st Floor: Wood Frame, 24" o .c. 731 18.2 0.0 34 Window 132: Wood Frame:Double Pane 21 0.310 7 Window 133: Wood Frame:Double Pane 16 0.310 5 Window 134: Wood Frame:Double Pane 16 0.310 5 Window 135: Wood Frame:Double Pane 21 0.310 7 Window 136: Wood Frame:Double Pane 11 0.310 3 Door E108: Solid 21 0.320 7 Door E109: Solid 21 0.320 7 Arched Door: Glass 35 0.310 11 SunRoom Stone Wall: Solid Concrete or Masonry:No Insulation 104 35 SunRoom Walls: Wood Frame, 24" o .c. 510 18.2 0.0 12 Window 111: Wood Frame:Double Pane 12 0.310 4 Window 112: Wood Frame:Double Pane 5 0.310 2 Window 113: Wood Frame:Double Pane 12 0.310 4 Window 114: Wood Frame:Double Pane 7 0,310 2 Project Title: Highland House Report date: 03/20/09 Data fllename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck Window 115: Wood Window 116: Wood Window 117: Wood Window 118: Wood Window 119: Wood Window 120: Wood Window 121: Wood Window 122: Wood Window 123: Wood Window 124: Wood Window 125: Wood Window 126: Wood Window 127: Wood Window 128: Wood Window 129: Wood Window 130: Wood Window 131: Wood Door E105: Glass Door E106: Glass Door E107: Glass Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane West Wall 2nd & 3rd Floor: Wood Frame, 24" o .c. Window 215: Wood Frame:Double Pane Window 216: Wood Window 217: Wood Window 218: Wood Window 219: Wood Window 231: Wood Window 220: Wood Window 221: Wood Window 222: Wood Window 223: Wood Window 232: Wood Window 224: Wood Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Single Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Double Pane Frame:Single Pane Frame:Double Pane Window 307: Wood Frame:Double Pane Window 308: Wood Frame:Double Pane South Wall 1 st Floor: Wood Frame, 16" o.c. Window 107: Wood Frame:Double Pane Window 108: Wood Frame:Double Pane Window 109: Wood Frame:Double Pane Window 110: Wood Frame:Double Pane South Wall 2nd & 3rd Floor: Wood Frame, 24" o .c. Window 211: Wood Frame:Double Pane Window 212: Wood Frame:Double Pane Window 213: Wood Frame:Double Pane Window 214: Wood Frame:Double Pane Window 306: Wood Frame:Double Pane East Wall 1st Floor: Wood Frame, 24" o .c. Window 102: Wood Frame:Double Pane Window 103: Wood Frame:Double Pane Window 104: Wood Frame:Double Pane Window 105: Metal Frame:Double Pane Window 106: Wood Frame:Double Pane Window 138: Wood Frame:Single Pane Window 139: Wood Frame:Single Pane Window 140: Wood Frame:Single Pane Window 225: Wood Frame:Single Pane Window 226: Wood Frame:Single Pane 24 0.310 7 7 0.310 2 7 0.310 2 24 0.310 7 7 0.310 2 7 0.310 2 24 0.310 7 7 0.310 2 7 0,310 2 12 0.310 4 5 0.310 2 12 0.310 4 7 0.310 2 12 0.310 4 3 0.310 1 12 0.310 4 12 0.310 4 34 0.310 11 34 0.310 11 18 0.310 6 425 18.2 0.0 17 13 0.310 4 13 0.310 4 13 0.310 4 5 0.310 2 7 0.310 2 18 0.310 6 7 0.310 2 9 0.310 3 9 0.310 3 9 0.310 3 19 0.310 6 9 0.310 3 5 0.310 2 5 0.310 2 219 18.2 0.0 10 14 0.310 4 14 0,310 4 14 0.310 4 14 0,310 4 420 18.2 0.0 22 10 0.310 3 10 0.310 3 10 0.310 3 10 0.310 3 10 0.310 3 751 18.2 0.0 36 8 0.310 2 6 0.310 2 15 0.310 5 15 0.310 5 15 0.310 5 6 1.010 6 6 1.010 6 6 1.010 6 6 1.010 6 6 1.010 6 Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck Window 207: Wood Window 208: Wood Window 209: Wood Window 228: Wood Window 229: Wood Window 230: Wood Window 210: Wood Window 303: Wood Window 304: Wood Window 227: Wood Frame:Single Pane 6 1.010 6 Window 141: Wood Frame:Double Pane 7 0.310 2 Door E104: Solid 30 0.320 10 Door E103: Solid 19 0.320 6 East Wall 2nd & 3rd Floor: Wood Frame, 24" o .c, 431 18.2 0.0 20 Window 205: Wood Frame:Double Pane 9 0.310 3 Frame:Double Pane 9 0.310 3 Frame:Double Pane 13 0.310 4 Frame:Double Pane 9 0.310 3 Freme:Single Pane 11 1.010 11 Frame:Single Pane 11 1.010 11 Frame:Single Pane 11 1.010 11 Frame:Double Pane 14 0.310 4 Frame:Double Pane 5 0.310 2 Frame:Double Pane 7 0.310 2 Window 305: Wood Frame:Double Pane 7 0.310 2 Slope wall: Wood Frame, 24" o .c. 644 49.2 0.0 24 Crawl Space Wall: Wood Frame 483 30.6 0.0 100 Wall height: 3.0' Depth below grade: 0.0' Insulation depth: 3.0' Inside below-grade depth: 0.9' Sun Room Floor: All-Wood Joist/Truss:Over Unconditioned Space 370 35.7 0.0 10 Basement Ceiling: All-Wood Joist/Truss:Over Unconditioned Space 453 35.7 0.0 13 Overhung - 2nd Floor: All-Wood Joist/Truss:Over Outside Air 498 52.6 0.0 10 Furnace 1: Forced Hot Air 95 AFUE Air Conditioner 1: Electric Central Air 13 SEER The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliarl~ce with this Code. Name - Title Signature Project Title: Highland House Report date: 03~20~09 Data filename: K:tl-ACTIVE PROJECTS\127-Lawrencet127 ( Main House)\cadtPermit Set\REScheck\Final Lawrence Rescheck REScheck Software Version 4.2.1 Inspection Checklist Ceilings: Roof/Ceiling 2nd & 3rd Floor: Cathedral Ceiling (no attic), R~.9.2 cavity insulation Comments: Above-Grade Walls: ~1 North Wall 1st Floor: Wood Frame, 24" o .c., R-18.2 cavity insulation Comments: [] North Wall 2nd & 3rd Floor: North Wall 2nd & 3rd Floor, R-18.2 cavity insutation Comments: I~1 West Wall 1st Floor: Wood Frame, 24" o .c., R-18.2 cavity insulation Comments: SunRoom Stone Wall: Solid Concrete or Mason~:No Insulation, R-0 (uninsulated) Comments: [] SunRoom Walls: Wood Frame, 24" o .c., R-18.2 cavity insulation Comments: [] West Wall 2nd & 3rd Floor: West Wall 2nd & 3rd Floor, R-18.2 cavity insulation Comments: [] South Wall 1st Floor: Wood Frame, 16" C.C., R-18.2 cavity insulation Comments: South Wall 2nd & 3rd Floor: South Wall 2nd & 3rd Flcor, R-18.2 cavity insulation Comments: [] East Wall 1st Floor: Wood Frame, 24" o .c., R-18.2 cavity insulation Comments: [] East Wall 2nd & 3rd Floor: East Wall 2nd & 3rd Floor, R-18.2 cavity insulation Comments: [] Slope wall: Wood Frame, 24" o .c., R-49.2 cavity insulation Comments: Windows: Window 101: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 137: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No [] Window 201: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: [] Window 202: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)~cad\Permit Set~REScheck\Final Lawrence Rescheck #Panes Frame Type Thermal Break? Yes __ No Comments: [] Window 203: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 204: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 301: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type __ Thermal Break? Comments: Yes -- No Yes __ No [] Window 302: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 206: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments:. Yes__No No [] Window 132: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No Yes__No ~1 Window 133: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: [] Window 134: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: ~1 Window 135: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 136: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? __ Yes No Comments: ~1 Window 111: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes __ No Comments: [] Window 112: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes __ No Comments: Project Title: Highland House Report date: 03/20/09 Data fllename: K:\I-ACTIVE PROJECTS\127-Lawrencet127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck [] Window 113: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 114: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 115: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No ~1 Window 116: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 117: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Yes__No [] Window 118: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 119: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 120: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type _ Thermal Break? Comments: Yes No Yes __ No [] Window 121: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 122: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 123: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 124: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 125: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: Project Title: Highland House Report date: 03/20~09 Data fllename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)~cad\Permit Set~REScheck\Final Lawrence Rescheck #Panes Frame Type Thermal Break? Yes __ No Comments: Window 126: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 127: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 128: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: ~1 Window 129: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No No [] Window 130: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No Window 131: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 215: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type . Thermal Break? Comments: Yes__No [] Window 216: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: ~1 Window 217: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No Yes__No [] Window 218: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 219: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No ~1 Window 231: Wood Frame:Single Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes __ No Comments: Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)\cad\Permit Set\REScheck\Final Lawrence Rescheck Window 220: Wood Frame:Double Pane, Uofactor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 221: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? __ Comments: [] Window 222: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Yes __ No [] Window 223: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: [] Window 232: Wood Frame:Single Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? __ Comments: Yes No Yes No Window 224: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No [] Window 307: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors descdbe features: #Panes Frame Type Thermal Break? __ Yes __ Comments: No Window 308: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No [] Window 107: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 108: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 109: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 110: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factom, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 211: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factors, describe features: Project Title: Highland House Repor~ date: 03/20/09 Data fllename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck Thermal Break? Yes __ No #Panes Frame Type Comments: Window 212: Wood Frame:Double Pane U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: Window 213: Wood Frame:Double Pane U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: No Yes No Window 214: Wood Frame:Double Pane U-factor: 0,310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No Window 306: Wood Frame:Double Pane U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Window 102: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No ~1 Window 103: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? __ Comments: [] Window 104: Wood Frame:Double Pane U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes Yes No No Window 105: Metal Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No Window 106: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 138: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 139: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Window 140: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes No Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)\cad\Permit Set\REScheck\Final Lawrence Rescheck Window 225: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No Window 226: Wood Frame:Single Pane, U-factor: 1,010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: Window 227: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: No Yes __ No ~1 Window 141: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Window 205: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes__No Yes__No Window 207: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No Window 208: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No ~1 Window 209: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: [] Window 228: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes -- No Yes No Window 229: Wood Frame:Single Pane, U-factor: 1,010 For windows without labeled U-factom, descdbe features: #Panes Frame Type Thermal Break? __ Comments: Yes No Window 230: Wood Frame:Single Pane, U-factor: 1.010 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Comments: Yes No Window 210: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Yes__No [] Window 303: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck Thermal Break? Yes __ No #Panes Frame Type Comments: I~ Window 304: Wood Frame:Double Pane, U-factor: 0.310 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: [] Window 305: Wood Frame:Double Pane, U-factor: 0,310 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? Comments: Doors: ~1 Door E101: Solid, U-factor: 0.320 Comments: ~1 Doer E102: Solid, U-factor: 0.320 Comments: I~ Door E108: Solid, U-factor: 0.320 Comments: No Yes __ No [] Door E109: Solid, U-factor: 0.320 Comments: [] Arched Door: Glass, U-factor: 0.310 Comments: [] Door E105: Glass, U-factor: 0.310 Comments: [] Door E106: Glass, U-factor: 0.310 Comments: [] Door E107: Glass, U-factor: 0.310 Comments: [] Door E104: Solid, U-factor: 0.320 Comments: [] Door E103: Solid, U-factor: 0.320 Comments: Floors: F~1 Sun Room Floor: Ali-Wood Joist/Truss:Over Unconditioned Space, R-35.7 cavity insulation Comments: [] Basement Ceiling: Ali-Wood Joist/Truss:Over Unconditioned Space, R-35.7 cavity insulation Comments: [] Overhung - 2nd Floor: Ali-Wood Joist/Truss:Over Outside Air, R-52.6 cavity insulation Comments: Crawl Space Walls: ~1 Crawl Space Wall: Wood Frame, 3.0' ht / 0.0' bg / 3.0' ext. insul / 0.0' inside bg depth, R-30.6 cavity insulation Comments: Applies to walls of unventilated crawl spaces. Heating and Cooling Equipment: ~1 Furnace 1: Forced Hot Air: 95 AFUE or higher Make and Model Number: ~1 Air Conditioner 1: Electdc Central Air: 13 SEER or higher Make and Model Number: Air Leakage: Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck ~1 Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. [] Recessed lights are 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, fixtures are installed with a 3" clearance from insulation. Vapor Retarder: [] Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment are installed in accordance with the manufacturer's installation instructions, [] Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. [] Insulation R-values, glazing U-factors, and heating equipment efficiency are cleady marked on the building plans or specifications. [] Insulation is installed according to manufacturer's instructions, in substantial contact with the sudace being insulated, and in a manner that achieves the rated R-value without compressing the insulation, Duct Insulation: [] Supply ducts in unconditioned attics or outside the buiidin0 are insulated to at least R-8. [] Return ducts in unconditioned attics or outside the building are insulated to at least R-4. F-I Supply ducts in unconditioned spaces are insulated to at least R-8. [] Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on retum ducts in basements. Duct Construction: [] All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [] The HVAC system provides a means for balancing air and water systems, Temperature Controls: [] Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [] Separate electric meters exist for each dwelling unit. Fireplaces: [] Fireplaces are installed with tight fitting non-combustible fireplace doom. [] Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [] Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is patt of a circulating system. [] Circulating hot water pipes ara insulated to the levels in Table 1. Circulating Hot Water Systems: [] Circulating hot water pipes are insulated to the levels in Table 1, Swimming Pools: [] All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: ~1 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Highland House Report date: 03/20/09 Dat~ filename: K:~I-ACTIVE PROJECTS\127-Lawrence~127 ( Main House)\cad~Permit Set\REScheck\Final Lawrence Rescheck Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Insulation Thickness in Inches by Pipe Sizes Fluid Temp. Range(OF) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Highland House Report date: 03/20/09 Data filename: K:\I-ACTIVE PROJECTS\127-Lawrence\127 ( Main House)Icad\Permit Set\REScheck\Final Lawrence Rescheck Z & S CONTRACTING, INC. BOX 202 · FISHERS ISLAND, NEWYORK 06390 Tel: (631) 788-7857 · Fax: (631) 788-5600 August 11, 2009 To: Mr. Bob Fisher and Mr. Brace Kinlin Concerning: Lawrence Residence Please find enclosed material submittals to coincide with previously submitted fire sprinkler system plans, for approval. Permit #34535 BLDG. DEP'(, TOWN OF SOUI'HOLD Sincerely, Paul Contillo Z & S Contracting, Inc. Lawrence Residence Fishers Island New York Stairwell Sprinkler CoveraRe MECHANICAL MATERIAL SUBMITTAL 1. TYCO BlazeMaster CPVC 2. BlazeMaster Brochure 3. BlazeMaster General Information 4. BlazeMaster Pipin§ Material 5. Potter RD ~.3 Riser Manifold 6. Viking Concealed Residential Pendent 7. Tolco Figure 24 Hanger 8. Tolco Figure 28 Hanger 9. Tolco Figure 29 Hanger 22 Edgewood Avenue Waterford, CT 06385 Phone: 860~137-8511 Fax 866~323-6825 email: bd_libertymechinc@snet, net /Fire & Building Products Technical Services: Tel: (800) 38%9312 / Fax: (800) 791 5500 rapid response` HOME FIRE SPRINKLER SYSTEM BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel oped thermoplastic compound corn posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade Various adapters are available to connect CPVC pipe to metallic pip- lng All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav lng jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and vices in proper operating condition The installing contractor or sprinkler manufacturer should be contacted w~th any questions, Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUb NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 '"Installation Instruction & Technical Handbook" for exact list- ingtapproval information) Manufacture Source U.S.A. Material · Pipe: ASTM F442, SDR 13.5 · Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaste¢ is a registered trademark of Noveon IP Holding Corp. Page I of 6 .JANUARY, 2006 TFP1915 Page Z of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGIIT FILLED WEIGIIT FT OF PIPE WEIGNT PER LIF, SIZE O D I D Ibs/fl lbs/8 PER LIFT lbs 3/4" 1 050" O 874' 0 18 0 44 7875 1339 1" 1 315" 1 101' 026 067 5040 1320 1 ~/4" 1 660" I 394~ 042 1 08 2835 1191 1-1/2' 1900" I 598" 0 54 I 41 2205 1213 2" 2 375" 2 003" 0 84 2 20 1260 1084 2-1/2" 2 875" 2 423" 1 26 3 26 1215 1531 3' 3500' 2 952" 1 87 483 720 1344 FIGURE I -- PIPE DIMENSIONS Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni cai Handbook". Care and Maintenance The owner is responsible for the in spection, testing, and maintenance of their fire protection system and de vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (eg., NFPA 25), in addition to the standards of any authority having jurisdiction. The in stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected. tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys tern must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE OUT SCHD WEIGHT TYPE NUMBER (710) (lb ) ~ J 80030 2 1/2" 1 9)16" 80 1 14 -- ~ [ 80031 3" 1-13/16" 80 1 82 FIGURE 2 -- FITTING DIMENSIONS (Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL TAKE OUT WEIGHT NOMINAL SIZE SCHD TYPE NUMBER (T/O) (lb) OD FIGURE 2 -- FITTING DIMENSIONS (Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL TAKE OUT WEIGHT TYPE NUMBER (T/O) (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4" x 1/2" NPT 7/16" 80 0 20 FIGURE 2 -- FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFP1915 '! - FIGURE 2 -- FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate* rial and workmanship when paid for and properly installed and maintained under norma[ use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fled or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Havin9 Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with lhe sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete informalion sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited lo labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The fore(]oin(] warranty is made in lieu of an~Land all other warranties, ex- Dress or imnlied, including warranties of merchantability and fitness for a Dar- ticular DurDose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 hen dealing with fire protection, you need a piping system : you can depend on. BlazeMaste/~ CPVC pipe and fittings are designed specifically for fire sprinkler systems and are based on more than 40 years of proven experience Lubrizol, the worldwide leader in CPVC innovation, takes fire sprinkler systems to a level of superior performance that exceeds your expectations. BlazeMaster fire sprinkler systems are the most advanced, Listed and approved non-metallic p~ping system available on the market today. And there's no comparison between CPVC pipe and metal pipe. CPVC systems offer more advantages than metal systems making all other pipes obsolete. Check the facts: Certified by NSF International for potable water safety under all water conditions Elimination of scaling and corrosion for lasting performance, even in salt air environments Natural immunity to Microbiologically Influenced Corrosion (MIC) Superior flow characteristics offer better hydraulic design over metal systems Ease of fabrication in the field provides unmatched flexibility Minimal tool investment generates increased cost savings 50-year life expectancy with a safety factor of two CPVC formulation delivers exceptional toughness Quality Assurance Program guarantees consistency and reliability BlazeMaster fire sprinkler systems are backed by an extensive field support organization, which is available for expert technical assistance and can provide you with: Proven installation recommendations to maximize efficiency and cost savings Expert consultation regarding compliance with local, regional and national codes Assistance with architects and engineers on design and specification work There are numerous advantages to using the BlazeMaster fire sprinkler technology to address your specific needs, including: Sprinkler Contradors · Improved durability: BlazeMaster CPVC pipe and fitting compounds have been specially formulated using Lubrizol technology for improved durability. It provides many advantages during installation, even at cold temperatures. · Cost savings: Overhead on tools is minimal since pipe can be cut o~site with simple hand tools. A one-step joining system makes installations even quicker, keeping labor to a minimum. General Conl;adors · Less conflict with other trades: Contractors installing BlazeMaster systems work easily and quickly around dry-wailers, framers and other mechanical contractors. · Lightweight: No special rigging or equipment is needed to move BlazeMaster pipe within the building. Builders and Developers · Low cost: Installed costs of a BlazeMaster system are significantly lower and prices are more stable than metal systems. Op~mal sized system: Smooth internal diameters lead to better hydraulic performance than metal which often means pipe can be downsized, lowering material costs. ® Architects and Engineen · Fully tested: BlazeMaster tire sprinkler systems have been thoroughly tested by UL, FM, UL-C, LPCB, VdS (Germany) and 7FRI (China). These systems have been exposed to flames reaching above 1400°F during fire tests and have been tested at twice the operating pressure continuously tot more ~an one year without signs of weakening or failure. · Design freedom: Lightweight and easy fabrication means BlazeMaster CPVC pipe and fittings are ideal for tho_s~ tou~hto- et at areas and in retrofit applications where their flexibility allows for quick, quiet and clean installations, which lead to occupancy benefits. avin§lurisdiction · Fully Listed and approved: BlazeMaster pipe and fittings are Listed by UL and UL-C for NFPA 13 light hazard occupancies, NFPA 13D, NFPA 13R, VdS approved, Tianjin Fire Research Institute approved, approved by Factory Mutual and all major model building and mechanical codes. · Proven per'l'ormance: BlazeMaster CPVC fire sprinkler systems have a proven track record of reliable performance since it's introduction in ] 984~ Lubrizors Quality Assurance Program, unsurpassed in the industry, ensures that this reliability will be maintained for many years to come. To put it simply- BlazeMaster CPVC pipe and fittings are the standard in fire sprinkler system protection. For further information call 888-234-2436 or visit our website at ye, . ~ ~ t Lubrizol lubrizol Advanced Materials, Inc BlazeMaster Marketing Depadment 9911 Brecksviile Road Cleveland, OH 44141 320] USA 2]6-4475000 888-234-2436 Fax: 216447 5750 Chaussee de Wavre, 1945 1160 Brussels Belgium 322478 19 ]1 Fax: 32 2 67&]990 ] 107 1110 Shui On Centre 68 Harbour Road Wan Chai, Hong Kong 8522508-1021 Fax: 852-2512224] BlazeMaster~ pipe and fittings are produced to stringent quality standards, established by Lubrizol, that exceed ASTM and other industry standards. Lubrizol has partnered with eight high quality manufacturers of pipe and fittings to bring the BlazeMaster system to market. Each manufacturer of the pipe participates in a Quality Assurance Program that ensures that these high standards are maintained for your peace of mind. This program is umque to Lubrizol and includes testing on strength and ductility and other physical properties of the pipe as well as dimensional tolerances. Lubrizol remains the technology leader and primary source of CPVC materials worldwide. While we do not manufacture pipe and fittings, we maintain a close and active relationship with the pipe and fittings manufacturers. Ask for the details of the warranty program from these BlazeMaster manufacturers. For a complete listing of regional sales representatives and manufacturers, please visit our website at www. blazemaster, com. BMO02US ® BlazeMas~er is a registered trademalk of The LubBzol Corporation © 2007 The Lubrizol Corporabon The info~ma0on contained here}n is believed to be re)iable, but no representations, a~etherespoasibilityoftbeuser. LubrizolAdvancedMaterials, Us¢.shallno~beliablefor and applications or the results 1o be obtained therefrom The intorrnation is based on laboratory lubrizol Advanced Materials, Inc's direct control THE SELLER MAKES NO WARRANTIES, work with small scale equipment and does not necessarily indicate end product periormance EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF Because of the variations in alethods, conditions and equipment used commercially in MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Nothing contained herein Printed in US.A. 06/07 FIRE SPRINKLER SYSTEMS Hangers and Bracing Because BlazeMaster p~pe is rigid, it requires fewer suppods than flexible plastic systems. Most hangers designed for metal p~pe are suitable for BlazeMaster pipe. Do not use undersized hangers. Hangers with sufficient load bearing surface shall be selected based on pipe size, ie., 1-1/2" hangers for 1-1/2" pipe. The hanger shall not have rough or sharp edges which come in contact with the pipe. The pipe hangers must comply with the requirements in NFPA 13, 13R, and 13D. For Quick Response upright sprinklers, rigid hangers secured to the ceiling shall be used. For installation of exposed BlazeMaster CPVC, listed support devices for thermoplastic sprinkler piping or other listed support devices shall be used which mount the piping directly to the ceiling or sidewall. When a sprinkler head activates, a significant reactive force can be exerted on the pipe. With a pendent head, this reactive force can cause the pipe to lift vertically if it is not properly secured, especially if the sprinkler drop is from small diameter pipe. The closest hanger shall brace the pipe against vertical lift-up. Since BlazeMaster CPVC is more ductile than metallic sprinkler pipe, it has a greater capacity to withstand earthquake damage. In areas subject to earthquakes, BlazeMasler fire sprinkler systems shall be designed and braced in accordance with local codes or NFPA 13. Transition to Other Materials BlazeMaster male and female threaded adapters or flanges are Listed for connecting a BlazeMaster system to other materials, valves, and appurtenances. A special reinforced female threaded adaptor is available for connection to the sprinkler head. A thread sealant shall be used in making threaded connections. TFE (Teflon®) thread tape is a recommended seal- ant. Other acceptable sealants are those that meet the standards of the FGG/BM® System Compatible Program. These are shown at www.blazemaster.com Some thread sealants other ,Loo./ \M / / 9911 Brecksville Rd. Cleveland, OH 44141-3201 than those mentioned previously contain solvents or other materials that may be damaging to CPVC. Always consult with the manufacturer of the material for com- patibility with BlazeMaster CPVC pipe and fittings. Care shall be exercised when transitioning between BlazeMaster pipe and fittings and metal Care must be taken to avoid over-torquing. Generally, 2 turns beyond finger tight is all that is required to make up a threaded connection (approximate torque should be 10-25 ft. pounds). Grooved Coupling Adapters CPVC Grooved Coupling Adapters were designed usin9 the Victaulic style 75 flexible couplin9 Other UL Listed couplings of similar design may be used. Caution: Use of rigid style couplings may damage the grooved coupling adaptor. Lubricate the gasket with a vegetable soap base gasket lubricant - IPS Weld ON Gasket/Joint Lubricant//787 or Seacord Corp Ease-On Pipe Joint Lubricant Caution: Certain lubricants may contain a petroleum base or other chemicals which will cause damage to the gasket and adapler. Always con- sult with the manufacturer of the lubricant for compal- ibility with BlazeMaster CPVC pipe and fittings. DO NOT USE vegelable oils, such as Crisco', as a lubricant. BlazeMaster Pipe Dimensions SDR 13.5 (ASTM F442) Inches (Millimeters) 3/4" (200) 1" (25.0) __._~_- 1/4" (32.0~ 1-1/2" (40.0) 2" (50.0) 2-'L/2" (65.O) 3" (80.0) Average OD 1.050 __ (267) 1.315__ ._ (33 4) 1.660 (42.2,l__ 1.900 (483) 2.375 (60.3) 2.875 (73.0) 3.500 (88.9) Avera9~ ID .874 1.101 I 394 1.598 2 003 2.423 2.951 Pounds/Ft. _(22 2) 168 128.0) 262 (35.4) __/L~8 ..... __(406) 548 (50.9) 859 (61.5) 1.257 (75.0) 1.867 Allowance For Friction Loss In CPVC Fittings __jf~f, CJreSSp./LJ~Equivalent Feet Of Pipe) Pipe Diameter ~itting 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" Tee Branch 3 5 6 8 10 12 15 Elbow 90° 7 7 8 9 11 12 13 Elbow 45° 1 1 2 2 2 3 4 Coupling 1 1 1 _J_ I 2 2 Tee Run 1 I 1 1 I 2 2 BlazeMaster Pipe SDR 13.5 (ASTM F442) Hanger Spacina Nominal Size Max Spacing inches (mm) feet (m) 3/4" (20.0) 5.5' fl .71 1" (25.0) 6.0' fl 1-1/4" (32.0) 6.5' (20) 1-1/2" (400) 7.0' (2.1) 2" (50.0) 60' f24) 2-1/2" (65.0) 9 O' (2.7) 3" (80,0) 10.0' (3.0) FIRE SPRINKLER SYSTEMS Comparison Of Fire Sprinkler Piping Materials In June 1994 the Building and Fire Research Laboratory of the National Institute of Standards and Technology (NIST) with a grant from 1he United States Fire Administration. conducted a literature based study comparing the characteristics of Chlorinaled Polyviny~ Chloride (CPVC), Polybutylene (PB), copper and steel tire sprinkler pipe primarily related to light hazard and residential installation. The report addresses key variables such as: · material properties · usage criteria and limilations · system design · installation requiremenls · economics · maintenance Attached is a summation of these variables affecting lire sprinkler pipe selection, For a copy of the complete report contact: Mr. Larry Maruskin United States Fire Administration Federal Emergency Managemenl Agency 16825 South Seton Avenue Emmitsburg, MD 21722 Ph: 301-447-1141 Fax: 301-447-1651 Note: Since the publication of this report several significant technical advancements have been made in the use of BlazeMasteF"¢ CPVC pipe. The method of joining CPVC pipe and fittings has been improved such that a primer is no longer required to be applied prior to the application of the solvent cement. Single step solvent cements have been developed that are easier to apply and just as strong as the primer with solvent cement method. Additionally BlazeMasted~ pipe and fittings are now listed by Underwriters Laboratories and approved by Factory Mutual to be installed exposed (without protection). 9911 Brecksville Rd. Cleveland, OH 44141-3201 N NISTIR 5339 Comparison of Fire Sprinkler Piping Materials' Steel, Copper, Chlonnated Polywnyl Chloride and Polybutylene in Residential and Light Hazard Installations Kalhy A. Notafianni and Margaret A. Jackson U.S. DEPARTMENT OF COMMERCE Sponsored by: Federal Emergency Management Agency United States Fire Administration 16825 S. Seton Avenue Emmitsburg, Maryland 21727 Property color Summation of Variables Affecting Fire Sprinkler Pipe Selection Pipe or Tube Type Typical Steel lightwall Copper i CPVC Pi] Sch. 40 steel Type M SDR 13.5 SDR 11 black silver copper bright orange grey weight of the DN25 (1 in.) size (kg/m) melting point (MP) or heat distortion temperature (HDT) damage susceptibility corrosion susceptibility design C factor occupancy classification NFPA standards maximum ambient temperature flexibility/hanger spacing for the DN25 (1 in.) size (m) expansion concerns/solutions 2.5 (MP) 1427-1538°C (2600-2800°F) IOW high/ 120 1 8 0.7 (MP) (MP) 1427-1538°C 1082°0 (2600-2800°F) (1980°F) Iow Iow high/ moderate/ 120 150 not limited fitting type compatible antifreeze not limited not flexible/ 3.7 negligible threaded grooved flanged plain-type nollimiled* not limited not limited not flexible/ 3.7 negligible threaded grooved flanged plaimtype not limited* not limited not limited slightly flexible/ 2.4 negligible soldering brazing grooved nol limited* 0.4 (HDT) 103°C (217°F) high with UV exposure and impacts Iow/ 150 0.2 (MP) 122-126°C (252-259°F) high with UV exposure and impacts Iow/ 150 NFPA 13 light hazard, 13D, 13R, concealed and restricted exposure NFPA 90A 66°C (150°F) flexible/ 1.8 yes/offsets direction changes, loops primer/solvent glycerine* NFPA 13 light hazard, 13D and 13R concealed only 49°C (t20°C) very flexible/ 10 yes/ snaking pipe heat fusion crimping ethylene glycol propylene glycol methanol glycerine* *NFPA recommends that only antifreeze solutions of glycerine or propylene glycol be used when the sprinkler system is connected to potable water POllER The '3ymbol of Protect/on CAUTION 'Ii,sting I he frcquuncv of inspection and lesling I~)~ Ihe Model VSR-SG and its associated protective momtormg s5 stem should be in accoldance with Poticr } Icctric Signal Compan), I I,C · 2081 Craig Road. St Louis, MC). 63146-4161 - Phone 800-325-3936/('anada 888-882-1833. x~'4 w pollcrsignal corn PO'I'T~ The Symbol of Protection October 4, 2007 Sprinkler t50u CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Emaih techsvcs~vikingcorp.com 1. DESCRIPTION Viking Freedom~: Residential Concealed Pendent Spr nkler VK468 ~s a small h~gh- senslbwty glass bulb res~denbal sprinkler for use w~th a domed cover assembly The orifice design, w~th a K Factor of 4 9 (70 6 metnc*) allows the spr nk e's efficient use of avatlable water supphes for the hydraulically designed fire protect on system The fast response glass bulb and speoal deflector combine speed of operation and areas of coverage to meet res~denttal spnnkler standards Concealed sprinkler VK468 is pre-assembled with a threaded adapter for installation w~th the domed cover that provides up to 1/2r' (12 7 mm) of vertical adjustment The cover plate is available wilh several decorative fimshes 1o meel design requirements The two p~ece design allows installation and testing of the spnnkler prior to installa- tion of the cover plate The "push-on', "thread-off' design of the concealed cover plate assembly allows easy mstallabon of the cover plate after the system has been tested and the ceding fimsh has been applied The cover assembly can be removed and reinstalled, allowing temporary removal of ceding panels w~thout taking the sprinkler system out of service or remowng the sprmMer 2. LISTINGS AND APPROVALS cULus Listed: Category VKKW NYC Approval: MEA 89-92-E Volume 35 NSF CerUfied: NSF/ANSI Standard 61, Drinking Water System Components Refer to the Approval Chart on page 150w and Design Criteria on page 150x for cULus Listing requirements that must be fol- lowed 3. TECHNICAL DATA Specifications: Available since 2006 Minimum Operating Pressure: Refer to the Approval Chad Maximum Working Pressure: 175 psi (12 bar) Factory tested hydrostatically to 500 psi (34 5 bar) Testing: USA Patent No. 4,831,870 Thread size: I/2" (15 mm) NPT Nominal K Factor: 4 9 U S (706 metric') *Metric K-factor measurement shown is when pressure ~s measured in Bar When pressure is measured in kPa, divide the metric K factor shown by 100 Glass bulb fluid temperature rated to -65 °F (-55 °C) Overall Length (Sprinkler Body): 2-1/4" (58 mm) Viking Technical Data may be found on The Viking Corporation's Web site at http:l/www.vikingg r ou pinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000. Phosphor Bronze UNS C51000, or Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleviile Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression Screw: Brass UNS C36000 Pip Cap: Bronze UNS-C31600 Cover Adapter: Cold Roiled Steel UNS-G10080. Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Plate Assembly: Copper UNS Cl1000 and Brass UNS C26800 Spring: Beryllium Nickel Solder: Eutectic Form No. F_020206 Replaces page 149u-z dated May 4, 2007, (Re-numbered and added NSF certification,) Sprinkler 150v October 4r 2007 I '~K~N~ FREEDOM® RESIDENTIAL1 CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Mt 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs~vikingcorp.com Ordering Information: (Also refer to the current Vikng pnce ~sl ) Viking Residential Concealed Pendent Sprinkler VK468 and Cover Plate Assembly must be ordered separately: Sprinkler: Base Pad No ~3637A-X (includes sprinkler and adapter pre-assembled, with a protective p~astic cap covering the unit) Specify sprinkler temperature rating by adding the appropriate suffx for the temperature ratio9 to the base pad number: Temperature Ratings rFFC): 155°/68° = B, 175°/79° -- D For example, concealed sprinkler VK466 with a 155 ~F/68 "C temperature rating - Pad No 13637ABX Note: When ordering thfs sprinkler using lhe SIN, add suffix D For example concealed sprinkler VK460 = VK468 D Cover Plate Assembly: Base Pad No 12207 Specify finish and temperature ratin9 of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature ratin9 to the base pad number: Finish Suffx Polished Chrome -- F, Painted White = M/SW1004 Painted Ivory - M-/SW1634, Painted Black = M4SW1007 Temperature Suffix (°FPC): 135~/57~ = A, For example, cover 12207 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 12207FA Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book ) Sprinkler Wrench: Part No 13577W/B** (available since 2006) '*A %" ratchet is required (not available from Viking) Sprinkler Cabinet: Five-head capacity: Pad No 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature= the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb 1o expand and the bulb to shatter, releasing lhe pip cap and sealing spring assembly. Water flowin9 through the sprinkler orifice strikes the spbnkler deflector, forming a uniform spray pattern to extinguish or control the fire 6, INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors See The Viking Corporation web site for lhe closest distributor or contact The Viking Corporation 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Ordinary 155 °F (68 °C) 100 °F (38 ~C) 135 °F (57 °C) 12207 Red Intermediate 175 "F (79 °C) 150 °F (65 "C) 135 °F (57 °C) 12207 Yellow Cover Plate Finishes: Polished Chrome Painted Wl~ite, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the deflector Based on NFPA-13, NFPA 13R, and NPFA 13D. Other limits may apply, depending on fire loading sprinkler location and other requirements of the Authority Having Jurisdiction Refer to specific installation standards Pad number shown is the base part number For complete pad number, refer to current Viking price list schedule October 4, 2007 Sprinker 150w [%IlKIN FREEDOM~ RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4,9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs~vikingcorp,com Sprinkler Base Part NumberI 13837A-X Maximum Areas of Coverage7 Minimum Water Supply Requirements7 Maximum Water Working Pressure 175 psi (12 bar) Listings and Approvals~ (Refer also to Design Criteria on cULusa I NYC= [ NSF~ Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5°). 12fl x12fl (37mx37m) I 13gpm@70psi(492L/min@048bar) AX1 AX1 14 fl x 14fl (43mx43m) 13 gpm@70 psi(492L/min@048bar) AX1 AX1 16ft x 16fl (49mx49m) 13 gpm@70 psi (492L/min@048bar) AX1 AX1 18ft. x18ft (5.5mx55m) i 17 gpm @12 0 psi (64 4 L/min @ 0 83 bar) AX1 AX1 AX1 20 It x 20 [t (6.1 m x 6 1 m) 20 gpm ~ 167 psi (75.7 L/mtn @ I 15 bar) AXI AX1 AX1 Installed below ceilings with slopes~ up to and including a 8/12 (33.7~) pitch. Refer to Figure 5 on page 150z. UL I NYC NSF~ x20ft (61 mx6 1 m) [ 26 gpm@282 psi (984L/mtn@ 194bar) BXl I -- BX1 2O It AX1 AX1 Sprinkler Temperature Ratings Cover Temperature Rating 1 Cover Plate Finishes - 155 °F (68 ~C) and 175 CF (79 ~C) 1 Polished Chrome. Painted White, Painted Ivory, and X 35 (57 Footnotes Pad number shown is the base pall number For complete part number refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar V~en pressure ~s measured in kPa, divide the metric K-faclor shown by 100 This chad shows the listings and approvals available al the lime of printing Other approvals may be in process Check with the manufacturer for any additional approvals Listed by Underwriter's Laboratories for use in the U S and Canada Accepted for use, City of New York Deparlment of Buildings, MEA Number 89 92-E, Vol 35 Tested and Cedified by NSF (National Sanitation Foundation) to NSF/ANSI Standard 61, Drinking Water System Components For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the nexl larger area listed. Flows and pressures lisled are per sprinkler. The distance from sprinklers to walls shall nol exceed one-half lhe sprinkler spacing indicated for the minimum Water Supply Requirement" used Areas under sloped ceilings must be measured along the ceiling slope. Actual floor coverage in the horizontal plane under sloped ceilings will be less than lhe lisled area of coverage Other paint colors are available on request with the same listings as the standard finish colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information Cuslom colors are indicaled on a label inside the cover assembly Refer to Figure 2 Sprinkler 150x October 4, 2007 ['~K~~ FREEDOMS) RESIDENTIAL ] CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs@vikingcorp.com cULus Listinq Requirements: VVhen using Viking Residential Concealed Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R. apply the listed areas of cover age and minimum water supply requifemenls shown in the Approval Chad on page 150w Forsystems desiq0ed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers ]he minimum required discharge from each of lhe four sprinklers is to be the grea~er of the following: Fha flow rates given in the Approval Chad on data page 150w for NFPA 13D and NFPA 13R applications for each listed area et coverage, or A minimum discharge of 0 1 gpm/fl (407 mm/rain) over the 'design area' consisting of the four contiguous most hydraulically demanding sprinklers for the coverage areas being protected by the four sprinklers NOTE; The A, - S x L method must be used to determine the sprinkler protection area of coverage per NFPA 13 Minimum distaDce beiween residential spdnklers 8 ft (24 m) · DEFLECTOR POSITION: Install Residential Concealed Pendent Sprinkler VK468 with the deflector 3/8" (9 5 mm) ~o 7/8' (222 mm) below the ceiling Refer to Figure 3 NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to 8ugetin Form No. F_091699 - Care and HaHdliH(j of Sprinklers. Aisc refer to pages RES1-17 for general care, in- stallation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 2: Identification of Custom Paint Color for Concealed Covers October 4. 2007 SprJnker 150y INIIKil FREEDOM®RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9} The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49055 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269~945-4495 Email: techsvcs@vikingcorp.com / Figure $: Sprlnk[er Dimensions and Cover Installation 1 Figure 4: Sprinkler Installation and Correct Use of Sprinkler Wrench Sprinkler 150z October 4, 2007 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com ¢: ~tL~'~'~ See Note 1 below ceiling ' 1 Listed areas of coverage corre slope{337~)-= 8/12 ~~~~; ~ . spond to areas measured along Refer to the Approval Chart for listed ceiling slope (For sloped ceiling installations, actual floor cover age in the horizontal plane under sloped ceilings will be less than the listed area) 2. Actual installations may require multiple sprinklers A single sprin- kter installalion has been shown for clarity 3 For "calhedfar' ceiling applica- tions, install sprinklers in a sym- metrical mirror-image of Figure 5. Figure 5: Instagation Instructions - Sloped Ceilings Form No. F_020206 Replaces page 149u-z dated May 4, 2007. (Re-numbered and added NSF certification ) Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range 3/4" thru 2" CPVC pipe Material Carbon Steel, Pre-Galvanized Function intended to perform as a hanger/restrainer to supporl only CPVC piping used in automatic fire sprinkler systems Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals -- Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features -- Fig 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the producl. II is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammerl or impact fasteners (such as drive screws or nails) are allowed Damage has been known to result from installations using impact type tools No pre-drilling of a pilot hole in wood is required. Finish -- Pre-Galvanized Order By -- Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions · Weights cPvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 Fig. 28 "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range -- %" through 2" Material -- Carbon Steel, Pre-Galvanized Function Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces. Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. The "Stand-Off" design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting surface orientation. Attaches easily to wood structure with two hex head self*threading screws furnished with product installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. Attaches easily to steel, minimum 18 gauge with (2) 114" x 1" lek lype self drilling tapping screws. U.L Listed as a hanger and a restrainer for fire sprinkler piping Approvals -- Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems May be inslalled into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D~ Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by -- Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. C A B Dimensions · Weights Pipe Approx. Size A B C Wt. 3/4 3¼2 2 37¢ .180 1 39~ 2:Y~ 372 210 174 3~ 2~ 3~ .225 1~ 4 21'5 3'~ 310 2 4F~ 2~Y~6 3Z~ 340 Fig. 29 - CPVC Double Offset Size Range Available in 3/4" and 1" pipe s~zes Material -- Carbon Steel Function -- Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 1 ~/2" x I ]'~' from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-flt attachment of hanger to sprinkler pipe. Features -- · Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is nol required to be bent for listed inslallation · Offset edge eliminates abrasion · Attaches easily to wood structure with two special #10 x 1 hex head self-lhreading screws furnished wilh product. Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish- Pre-Galvanized Order By -- Figure number and pipe size. PATENT PENDING Lawrence Residence Fishers Island New York Stairwell Sprinkler Coverage MECHANICAL MATERIAL SUBMITTAL 1. TYCO BlazeMaster CPVC 2. RlazeMaster Brochure 3. BlazeMaster General Information 4. glazeMaster Piping Material 5. Potter RD ~-3 Riser Manifold 6. Viking Concealed Residential Pendent 7. Tolco Figure 24 Hanger 8. Toico Figure 28 Hanger 9. Tolco Figure 29 Hanger 22 Edgewood Avenue Waterford, CT 06385 Phone: 860~437.6511 Fax 866-323-6825 email: bd_liber tymechinc~snet.n et tll~'O / Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 papidresponse" HOME FIRE ~PRINKLER ~YSTEM BlazeMaster ® CPI/C Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire & Building Products (TFBP) BIazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems They are made [rom a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems. and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the appfica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other aulhorilies haw lng jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les (Refer tolH-1900, Rev. 0, Janu ary 2005 "lnslallation Instruction & Technical Handbook" for exact list- ing/approval information ) Manufacture Source U.SA Material · Pipe: ASTM F442, SDR 13.5 · Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaste~ is a registered trademark of Noveon IP Holding Corp Page I of 6 JANUARY, 2006 TFP1915 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT OF PIPE WEIGHT PER LIFT SIZE 0 D I D Ibs/fl Ibf,/fl PER LIFT lbs 3/4" I 050" O 874" 0 18 0 44 7875 1339 1" 1 315" 1 101' 026 067 5040 1320 I 1!4" 1 660* 1 394" 042 1 08 2835 1191 1-1/2" 1 900" 1 598" 054 I 41 2205 1213 2" 2 375" 2 003" 0 84 2 20 1260 1084 2-1/2" 2 875" 2 423" 1 26 3 26 1215 1531 3" 3 500" 2952" 1 87 4 83 720 1344 FIGURE I -- PIPE DIMENSIONS Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be inslalled in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalking contractor or product manufac turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys fern must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified After placing a fire protection system in service, notify the proper authorities and advise those responsible for mom- toring proprielary and/or central sta- tion alarms. TFP1915 Page 3 of 6 F]~ING PART NOMINAL TAKE OUT WEIGHT NOMINAL SIZE SCHD TYPE NUMBER ~3'10) (~b.) oT/ ) 80140 I 1/2" x 1 1/4" x 3/4" 9i16" 9/16" 1" 80 0 36 -I L TiO FIGURE 2 -- FITTING DIMENSIONS (Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL TAKE OUT WEIGHT NOMINAL SIZE SCHD TYPE NUMBER (T/O} (lb ) OD I 80163 2-1/2" x 2-1/2" Groove 2-5/16" 2-1/2" (2 875") 80 2 28 FIGURE 2 -- FITTING DIMENSIONS (Part 2 of 4) TFP1915 Page S of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb ) SPRINKLER HEAD ADAPTER "J~ T/O FIGURE 2 -- FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD WEIGHT TYPE NUMBER (T/O) (lb } BACK-TO-BACX TEE X x Y x Z X Y, Z T/O FIGURE 2 -- FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted so~ely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The fore(]oine warranty is made in lieu of any and all other warranties ex- Dress or implied, including warranties of merchantability and fitness for a Dar- ticular DurDose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, mated- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law The invalidity, in whole or part, of any podion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 hen dealing with fire protection, you need a plp~ng system you can depend on. BlazeMaster'~ CPVC pipe and fittings are designed specifically for fire sprinkler systems and are based on more than 40 years of proven experience. Lubrizol, the worldwide leader in CPVC innovation, takes fire sprinkler systems to a level of superior performance that exceeds yonr expectations. BlazeMaster fire sprinkler systems are the most advanced, Listed and approved non metallic piping system available on the market today. And there's no comparison between CPVC pipe and metal pipe, CPVC systems offer more advantages than metal systems making all other pipes obsolete. Check the facts: Certified by NSF International for potable water safety under all water conditions Elimination of scalieg and corrosion for lasting performance, even in salt air environments Natural immunity to Microbiologically Influenced Corrosion (MIC) Superior flow characteristics offer better hydraulic design over metal systems Ease of fabrication in the field provides unmatched flexibility Minimal tool investment generates increased cost savings 50-year life expectancy with a safety factor of two CPVC formulation delivers exceptional toughness Quality Assurance Program guarantees consistency and reliability BlazeMaster tire sprinkler systems are backed by an extensive field support organization, which is available for expert technical assistance and can provide you with: Proven installation recommendations to maximize efficiency and cost savings Expert consultation regarding compliance with local, regional and national codes Assistance with architects and engineers on design and specification work There are numerous advantages to using the BlazeMaster fire sprinkler technology to address your specific ueeds, including: Sprinkler Contractors · Improved durability: BlazeMaster CPVC pipe and fitting compounds have been specially formulated using Lubdzol technology for improved durability. It provides many advantages during installation, even at cold temperatures. · Cost savings: Overhead on tools is minimal since pipe can be cut o~site with simple hand tools. A one-step joining system makes installations even quicker, keeping labor to a minimum. General Conltadors · Less conflict with other trades: Contractors installing BlazeMaster systems work easily and quickly around d~7-wallers, framers and other mechanical contractors. · Lightweight: No special rigging or equipment is needed to move BlazeMaster pipe within the building. Builders and Developers · Low cost: Installed costs of a BlazeMaster system are significantly lower and prices are more stable than metal systems. Optimal sized system: Smooth internal diameters lead to better hydraulic performance than metal which often means pipe can be downsized, lowering material costs. Archilecls and Engineers · Fully tested: BlazeMaster fire sprinkler systems have been thoroughly tested by UL, 1:M, UUC, LPCB, VdS (Germany) and 'ri:RI (China). These systems have been exposed to flames reaching above 1400°1: during fire tests and have been tested at twice the operating pressure continuously for more than one year without signs of weakening or failure. · Design freedom: Lightweight and easy fabrication means BlazeMaster CPVC pipe and fittings are ideal for tho_se toughtoget at areas and in retrofit applications where their flexibility allows for quick, quiet and clean installations, which lead to occupancy benefits. Authoritie~ HavingJurhdidion · Fully Listed and approved: BlazeMaster pipe and fittings are Listed by UL and UL-C for NFPA 13 light hazard occupancies, NFPA 13D, NFPA 13R, VdS approved, Tianjin 1:ire Research Institute approved, approved by Factory Mutual and all major model building and mechanical codes. · Proven performance: BlazeMaster CPVC fire sprinkler systems have a proven track record of reliable performance since it's introduction in 1984. Lubrizors Quality Assurance Program, unsurpassed in the industry, ensures that this reliability will be maintained for many years to come. To put it simply- BlazeMaster CPVC pipe and fittings are the standard in fire sprinkler system protection. For further information call 888-234-2436 or visit our website at Lubrizol Lubrizol Advanced Materials, Inc. BlazeMaster' Marketing Department 9911 Brecksvifle Road Cleveland. OH 4414] 3201 USA 2]64475000 888234-2436 Fax: 216447 5750 Chaussee de Wavre. ] 945 1 160 Brussels Belgium 32267819]] Fax: 322678]990 } 107 1 ] 10 Shui On Centre 6~3 Harbou[ Road Wan Chak Hong Kong 852 250&102] Fax: 852 2512-2241 BlazeMaster~ pipe and fi~ings are produced to stringent quality standards, established by Lubrizol, that exceed ASTM and other industry standards. Lubrizol has partnered with eight high quality manufacturers of pipe and fittings to bring the BlazeMaster system to market. Each manufacturer of the pipe participates in a Qualih/Assurance Program that ensures that these high standards are maintained for your peace of mind. This program is unique to Lubrizol and includes testing on strength and ductility and other physical properties of the pipe as well as dimensional tolerances. Lubrizol remains the technology leader and primary source of CPVC materials worldwide. While we do not manufacture pipe and fittings, we maintain a close and active relationship with the pipe and fittings manufacturers. Ask for the details of the warranty program from these BlazeMaster manufacturers. For a complete listing of regional sales representatives and manufacturers, please visit our website at www. blazemaster, com. BMOO2US B]azeMaste~® is a registered trademark of The Lubrizol Cot poratio~ Printed in U S A © 2007 Th~ Lubrizol Corporation 06/07 FIRE SPRINKLER SYSTEMS Hangers and Bracing Because BlazeMaster pipe is rigid, it requires fewer supports than flexible plastic systems. Mosl hangers designed for metal pipe are suitable for BlazeMaster pipe. Do not use undersized hangers. Hangers with sufficienl load bearing surface shall be selected based on pipe size, i.e., 1-1/2" hangers for 1-1/2" pipe The hanger shall not have rough or sharp edges which come in contact with the pipe. The pipe hangers must comply with the requirements in NFPA 13, 13R, and 13D, For Quick Response upright sprinklers, rigid hangers secured to lhe ceiling shall be used. For installation of exposed BlazeMaster CPVC, listed support devices for thermoplastic sprinkler piping or other listed support devices shall be used which mount the piping directly to the ceiling or sidewall, When a sprinkler head activates, a significant reactive force can be exerted on the pipe. With a pendent head, this reactive force can cause the pipe to lill vertically it it is not properly secured, especially if the sprinkler drop is from small diameter pipe. The closest hanger shall brace lhe pipe against vertical lift-up. Since BlazeMaster CPVC is more ductile than metallic sprinkler pipe, it has a greater capacity to withstand earthquake damage In areas subject to earthquakes, BlazeMasler fire sprinkler systems shall be designed and braced in accordance with local codes or NFPA 13. Transition to Other Materials BlazeMaster male and female threaded adapters or flanges are Listed for connecting a BlazeMaster system to other materials, valves, and appurtenances. A special reinforced female threaded adaptor is available for connection 1o the sprinkler head. A thread sealant shall be used in making threaded connections. TFE (Teflon®) thread tape is a recommended seal- ant. Other acceptable sealants are those that meet the standards of the FGG/BM® System Compatible Program. These are shown at www.blazemaster.com. Some thread sealants other 9911 Brecksvi]le Rd. Cleveland, OH 44141-3201 web site: e-mail: than those mentioned previously contain solvents or other materials that may be damaging to CPVC. Always consult with the maoufacturer of the material for corn- patibility with BlazeMaster CPVC pipe and fittings. Care shall be exercised when transitioning between BlazeMaster pipe and fittings and metal Care must be taken to avoid over-torquing. Generally, 2 turns beyond finger tight is all that is required to make up a threaded connection (approximate torque should be 10-25 ft. pounds). Grooved Coupling Adapters CPVC Grooved Coupling Adapters were designed using the Victaulic style 75 flexible coupling. Other UL Listed couplings of similar design may be used. Caution: Use of rigid style couplings may damage the grooved coupling adaptor. Lubricate the 9asker with a vegetable soap base gaskel lubricant - IPS Weld ON Gasket/Joint Lubricant//787 or Seacord Corp Ease-On Pipe Joint Lubricant. Caution: Certain lubricants may contain a petroleum base or other chemicals which will cause damage to the gasket and adapter, Always con- sult with the manufacturer of the lubricant for compat- ibility with BlazeMaster CPVC pipe and fittings. DO NOT USE vegetable oils, such as Crisco", as a lubricant. BlazeMaster Pipe Dimensions SDR 13 5 (ASTM F442) Inches (Millimeters) Nominal Size 3/4" 1" .... _-_114 _ (32.0) 1-1/2" (40.0) 2" (50.0) _ 2-1/2" (65.0) 3-____(80.0) Averagc__CJ~ (26 7) ~__ (33 4) 1.660 (42.2) 1.900 (483) 2.375 L6~3) 2875 3.500 (889) Average ID 874 (22 2)__ 1.394 (35.4) 1.598 (40.6) 2.003 (50.9) 2.951 (75.0) Pounds/Ft. 168 262 .... 418 859 1,257 1.867 Allowance For Friction Loss In CPVC Fittings (Expressed In Equivalent Feet OJJEilze)___ Pipe Diameter Fitting 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" Tee Branch 3 5 6 8 10 12 1 Elbow 90" 7 7 .... J~L__ 9 I 1 12 13 Elbow 45° 1 1 2 2 2 3 4 Coupling 1 1 _ ___J__ 1 _ 1 2 2 Tee Run 1 1 1 1 1 2 2 BlazeMaster Pipe SDR 13.5 (ASTM F442) Hanger Spacing Nominal Size Max Spacing .~Qches (mm) feet (m) 3/4" (20.0) 5.5' (1.7) 1" (25.0~ 6.0' (1.8) 1-1/4" (32.0) 6.5' (2.0) 1-1/2" (40.0) 7.0' (2.1) 2" (50.0) 8.0' (2.4) 2-1/2" (65.0) 9.0' (2.7) 3" rS0.0) 100' FIRE SPRINKLER SYSTEMS Comparison Of Fire Sprinkler Piping Materials In June 1994 the Building and Fire Research Laboratory of the National Institute of Standards and Technology (NIST) with a grant from the United States Fire Administration, conducted a literature based sludy comparing the characteristics of Chlorinaled Polyvinyt Chloride (CPVC), Polybutylene (PB). copper and steel tire sprinkler pipe primarily related to light hazard and residential installation. The report addresses key variables such as: · material properties · usage criteria and limitations · system design · installation requirements · economics · maintenance Attached is a summation of these variables affecting lire sprinkler pipe selection. For a copy of the complete repod contact: Mr. Larry Maruskin United States Fire Administration Federal Emergency Management Agency 16825 South Seton Avenue Emmitsburg, MD 21722 Ph: 301-447-1141 Fax: 301-447-1651 Note: Since the publication of this report several significant technical advancements have been made in the use of BlazeMaster'~ CPVC pipe. The method of joining CPVC pipe and fittings has been improved such that a primer is no longer required to be applied prior to the application of the solvent cement. Single step solvent cements have been developed that are easier to apply and just as strong as the primer with solvent cement method. Additionally BlazeMaster~ pipe and fittings are now listed by Underwriters Laboratories and approved by Factory Mutual to be installed exposed (without protection). 9911 Brecksvilte Rd. Cleveland, OH 44141-3201 N NISTIR 5339 Companson of Fire Sprinkler Piping Materials: Steel, Copper, Chlorinated Polywnyl Chloride and Polybutylene in Residential and Light Hazard Installations Kathy A. Notarianni and Margaret A. Jackson U.S. DEPARTMENT OF COMMERCE Sponsored by: Federal Emergency Management Agency United States Fire Administration 16825 S. Seton Avenue Emmitsburg, Maryland 21727 Summation of Variables Affecting Fire Sprinkler Pipe Selection Typical Steel lightwall Property Sch. 40 steel color black silver weight of the DN25 (1 in.) size (kg/m) 2.5 1 8 melting point (MP) or heat distortion temperature (HDT) damage susceptibility corrosion susceptibility design C factor occupancy classification NFPA standards maximum ambient temperature flexibility/hanger spacing for the DN25 (1 in.) size (m) (MP) 1427-1538°C (2600-2800°F) Iow high/ 120 not limited not limited Pipe or Tube Type Copper i CPVC PB Type M ~ SDR_ 13.5 SDR 11 copper bright orange ~ grey 0.7 0.4 ~ 0.2 (MP) ' --iMP) (HD~i [~M'~i 1427-1538°C (2600-2800° F) Iow high/ 12O not limited not limited 1082°C (1980°F) 103°C (217°F) high with UV Iow exposure and impacls moderate/ Iow/ 150 150 not limited not limited s~ightly flexible/ 2.4 NFPA 13 light hazard, 13D, 13R, concealed and restricted exposure NFPA 90A 66°C (150°F) 122-126°C (252-259°F) high with UV exposure and impacls Iow/ 150 NFPA 13 lighl hazard, 13D and 13R concealed only 49°C (t20°C) not flexible/ not flexible/ flexible/ very flexible/ 3.7 3.7 1.8 1.0 expansion yes/offsets yes/ concerns/solutions negligible negligible negligible direction snaking pipe changes, loops threaded threaded fitting type grooved grooved soldering primer/solvent heat fusion flanged flanged brazing cement crimping plain-type plain-type grooved ethylene glycol compatible propylene glycol antifreeze not limited* not limited* not limited* glycerine* methanol glycerine* 'NFPA recommends that onl ¢ antifreeze solutions ol glycerine or propylene glycol be used when the sprinkler system is connected to potable water POTTER The Symbol of Protection l~x i) 1 3 ~, I S E R ~, OAUTION with all national and Jocal codes and ordinances Poilcr} ]cctric Signal Compan.x. l LC - 2081 Craig Road. SI louis, kIO. 03146-416 ] · Phone 800-325-3936/Canada 888-882-1833 · wv, w potlers~gnal corn The Synlbot of Protection Retard Adjustmenl ] he delta can be a~[}usled b3 rolating Ihe relard adjuslmenl knob Io die max setting {60-90 seconds). Ibc time dcla !/!)13 RISER October 4. 2007 Sprinkler t50u FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-8184680 Email: techsvcs~vikingcorp.com 1. DESCRIPTION Viking FreedDm* Res~denPal Concealed Pendent Sprinkler VK468 is a small h[gh- sens~hwty glass bulb res~denbal spnnkler for use w~th a domed cover assembly The orifice design wdh a K-Factor of 4 9 (70 6 metric') allows the sprinkler's efficient use of available water supplies for the hydrauhcally designed fire protechon system. The fast response glass bulb and spec*al deflector combine speed of operation and areas of coverage to meet residential spnnkler standards Concealed sprinkler VK468 is pre-assembled with a threaded adapter for installation with the domed cover that provides up to %' (127 mm} of vedlcal adjustment The cover plate ~s available with severa~ deooratwe finishes to meet design requirements The two-piece design allows installation and testing of the spnnkler prior to ~nstalla- tion of the cover plate The "push on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling hmsh has been applied The cover assembly can be removed and reinstalled allowing temporary removal of ceding panels w~thout taking the sprinkler system out of service or removing the sprinkler 2. LISTINGS AND APPROVALS cULus Listed: Category VKKW NYC Approval: MEA 89-92-E, Volume 35 NSF Certified: NSF/ANSI Standard 61, Drinking Water System Components Refer to the Approval Chad on page 150w and Design Criteria on page 150x for cULus Listing requirements that must be fol- lowed 3. TECHNICAL DATA Specifications: Available since 2006 Minimum Operating Pressure: Refer to the Approval Chart Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34 5 bar) Testing: U SA Patent No 4,831,870 Thread size 1/2" (15 mm) NPT Nominal K-Factor 49 US. (706 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar VVhen pressure is measured in kPa. divide the metric K factor shown by Glass-bulb fluid temperature rated to -65 °F (-55 ~C) Overall Length (Sprinkler Body): 2-1/4' (58 mm) Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikingg ro u pinc.co m. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy. coated on both sides with Teflon Tape Compression Screw: Brass UNS-C36000 Pip Cap: Bronze UNS-C31600 Cover Adap er: Cold Ro ed Stee UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Form No F_020206 Replaces page 149u-z dated May 4, 2007. (Re-numbered and added NSF certification.) Sprinkler 150v October 4. 2007 CONCEALED PENDENT SPRINKLER VK468 {K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs{~vikingcorp,com Ordering Information: (Aisc refer to the current V~k~9 ~r:e sl ) Vikin9 Residential Concealed Pendent Sprinkler VK468 and Cover Plate Assembly must be ordered separately Sprinkler: Base Part No 13637A-X (includes sprinkler and adapter pre-assembled, with a protective plastic cap covering the unit) Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Ratings aFFC): 155~/68° - B, 175°/79° = D For example concealed sprinkler VK468 with a 155 ¢F/68 °C temperature rating = Part No 13637ABX Note: When ordering this sprinkler using the SIN, add suffix D For example, concealed sprinkler VK468 - VK468 D Cover Plate Assembly: Base Pad No 12207 Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base pad number: Finish Suffix Polished Chrome - F, Painted White - M-/SW1004 Painted Ivory = M-/SW1634, Painted Black - M-/SWl007 Temperature Suffix (°F?C): 135°/57" = A, For example, cover 12207 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 12207FA Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Aisc refer to the "Sprinkler Accessories" section of the Viking data book) Sprinkler Wrench: Part No 13577W/B** (available since 2006) '*A ¼" ratchet is required {not available from Viking) Sprinkler Cabinet: Five-head capacity Part No 01731A (avai{able since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperaturer the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the pip cap and seafing spring assembly Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors See The Viking Corporation web site for the closest distribulor or contact The Viking Corporation 8. GUARANTEE For details of warranfy, refer to Viking's current list price schedule or contacl Viking directly Ordinary 155 "F (68 °C) 100 °F (38 DC) 135 ~F (57 °C) 12207 Red Intermediate 175 ~F (79 °C) 150 °F (65 'C) 135 "F (57 °C) Cover Plate Finishes: Polished Chrome Painted White, Painted Ivory, or Painted Black 12207 Yellow Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13, NFPA 13R. and NPFA 13D Other limits may apply~ depending on fire loading sprinkler location, and other requirements of the Authod~ Having Jurisdiction Refer to specific installation standards Pad number shown is the base part number. For complete pad number, refer to current Viking price list schedule October 4, 2007 Sprinker 150w INIKIN FREEDOM®RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Vikin9 Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs~vikingcorp.com Part Number mm 13637A-X 1/2 L 15 i 4 9 I 706 175 psi (12 bar) 58 i Listings and Approvals3 Maximum Areas of Coverage7 I {Refer also to Design Criteria on page 150x,) i Minimum Water Supply Requirements? Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5°). 12 It x 12 g (37 m x 3 7 m) AX1 AX1 AX1 AX1 AX1 AX1 14It x14ft (43mx43m) 13 gpm @ 70 psi (492 t/min @ 04_8 bar) 13 gpm @ 70 psi (492 L/min @ 048 bar) 16flx16fl (4.9mx49m) [ 13gpm@70psi(492L/min@04~b~i ] AX1 " 17 gpm e 120 psi (644 ~i~ @ 0 83 bar) ~ ~¢-m~ ~ ps, (75.7 IJm,~@ 1 15 ba;; 18fl x18ft {55mx55m) 20fl. x20fl (61mx61m) AX1 AX1 AX1 AX1 AX1 AX1 AX1 AX1 Installed below ceilings with slopes up to and including a 8112 (33.7) pitch. Refer to Figure 5 on page t$0z. 20 fl x 20 fl (6 1 m x 6 1 m) i, 26 gpm @ 28 2 psi (984 L/mtn @ 194 bar) -.,. I Sprinkler Temperature Ratings Cover Temperature Rating 1 /~ Cover Plate Finishes 155 °F (68 ~C)and 175"F (79 C) - Polished Chrome, Painted White, Painted Ivory, and - 155 F (69 ~C) X - 135 °F (57 ~C) Painted Black~ Footnotes Part number shown is the base part number For complete pad number refer to Viking's current price schedule. Metric K factor measurement shown is when pressure is measured in Bar When pressure is measured in kPa, divide the metric K-factor shown by 100. This chad shows the listings and approvals available al the time of printing Other approvals may be in process. Check wdh the manufacturer for any additional approvals Listed by Underwriter's Laboratories for use in the US. and Canada Accepted for use, City of New York Depadment of Buildings, MEA Number 89 92 E, Vol 35 Tesled and Certified by NSF (National Sanitation Foundation) to NSF/ANSI Standard 61, Drinking Water System Components For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger area listed. Flows and pressures lisled are per sprinkler The distance from sprinklers to wails shall not exceed one half lhe sprinkler spacing indicated for the minimum Water Supply Requirement" used Areas under sloped ceilings must be measured along the ceiling slope Actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area of coverage Other paint colors me available on request with the same listings as the standard finish colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information Custom colors are indicated on a label inside the cover assembly. Refer to Figure 2. Sprinkler 150x October 4, 2007 l'~~~ FREEDOM®RESIDENTIAL ] CONCEALED PENDENT SPRINKLER VK468 {K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 769-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs~vikingcorp,com cULus Listinq Requirements: V~en using Viking Residential Concealed Pendent Sprif~kler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chad on page 150w Eo£_syst.em~ designed to NFPA t 3 ] he number of design sprinklers is to be lbo four contiguous most hydraulically demanding sprinklers The m~n~mum required dischaige from each of the four sprinklers is to be the grea~er of the following · The flow rates given in the Approval Chart on data page 150w for NFPA 13D and NFPA 13R applications for each listed area of coverage, or · A minimum discharge of 0 I gpm/g (407 mm/min) over the 'design area consisting of the four contiguous most hydraulically demanding sprinklers for the coverage areas being protected by the four sprinklers NOTE; The A, = S x L method must be used to determine the sprinkler protection area of coverage per NFPA 13 · Minimum distance between residential sprinklers 8 fl (24 m) · DEFLECTOR POSITION: Install Residential Concealed Pendent Sprinkler VK468 with the deflector 3/8" (9 5 mm) to 7/8' (22 2 mm) below the ceiling Refer to Figure 3 NOTE: Conceated sprinklers must be installed in neutral or negative pressure plenums only, IMPORTANT: Always refer to Bu0etin Form No. F_091699 - Care and Hal)tilth9 of Sprinklers. Aisc refer to pages RES1-17 for general care, in- stallation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 1: Concealed Sprinkler VK468 with Protective Shell IIKIN6 Figure 2: Identification of Custom Painl Oolor for Concealed Covers October 4. 2007 Sprinker 150y CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Emaih techsvcs(~vikingcorp.com Figure 3: Sprinkler Dimensions and Cover installation Figure 4: Sprinkler Installation and Correct Use of Sprinkler Wrench Sprinkler 150z October 4, 2007 CONCEALED PENDENT SPRINKLER VK468 {K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269~945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs~vikingcorp.com ceiling sfope: 8/12 (337~) Refer 1o the Approval Chart for listed ceiling slope (For sloped ceiling the listed area ) Figure 5: Installation Instructions - Sloped Ceilings Form No. F_020206 Replaces page t49u-z dated May 4, 2007 (Re-numbered and added NSF certification ) Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range 3/4" thru 2" CPVC pipe Material Carbon Steel, Pre-Galvanized Function Intended to perform as a hangertrestra~ner to support only CPVC piping used in automatic fire sprinkler systems Can be installed on the top or on the bottom of a beam. The Fi9. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features Fi9. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC p~pe from any rough surface. Easily attaches to the building structure usin9 the two UL Listed hex head self threading screws** furnished with the product, it is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer or impact fasteners (such as drive screws or nails) are allowed Damage has been known to result from installations using impact type tools No pre-drilling of a pilot hole in wood is required, Finish Pre-Galvanized Order By Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions · Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft,) Head Size Wt.ll00 Fig. 28 "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range -- ~4" through 2" Material -- Carbon Steel, Pre-Galvanized Function Designed to be used as a hanger and restrainer for CPVC piping where the "stand off" design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces. Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. The "Stand-Off" design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting surface orientation, Attaches easily to wood structure with two hex head self-threading screws furnished with product. Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals -- Underwriters' Laboratory Listed in the USA (UL} and Canada (cUL) to support automatic fire sprinkler systems May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by -- Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. C A B Dimensions · Weights Pipe Approx. Size A B C Wt. 3/4 3¼2 2 3½ 180 1 3~6 2:~ 3~'~ 210 1¼ 3-~ 2~ 3;~ 225 lY~ 4 2~ 3~ 310 Fig. 29 - CPVC Double Offset Size Range Available in 3/4" and 1" pipe sizes Material Carbon Steel Function Intended to perform as a hanger and restrainer for CPVC. plastic fire sprinkler pipe Provides double offset 1 !,~"x I !?~' from mounting sun'ace. This design will ease installation by eliminating the need for wood block extension and allow retro fit attachment of hanger to sprinkler pipe. Features · Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installalion. · Offset edge eliminates abrasion. · Attaches easily to wood structure with two special #10 x 1 hex head self-threading screws furnished with product, Approvals -- Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish -- Pre-Galvanized Order By -- Figure number and pipe size. PATENT PENDING I 500 preslig Solo Solo Water Boiler Trna nr..jleTube c us *INSTALLATION AND MAINTENANCE* MANUAL Warranty Registration Card must be filled out by the customer and mailed within thirty (30) days of installa- tion in order to gain warranty coverage. When receiving the PRESTIGE Solo unit, any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignce. Leave all documentation received with appliance with owner fi)r future reference. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS - Do not try to light any appliance - Do not much any electrical switch; do not use any phone in your building. - hnmedia, tely call your gas supplier from a neighbor's phone. Follow the gas supplier s instructtons. - If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Series Ill 2007-2 Manual Prestige Solo 60/175/250/399 - Revised 09/22/08 Product Specifications ~11~ Trl~ncjl~Tubi~ 17.2' [437 mini ~i~'[~05 mmI 14.70"[372mm] [180rn~ 2,00' 19.80.1~ mm] - I,~m Front View PRESTIGE Solo 175/250 314" Gas Connection 1-1/4" NPTBoiler Return 1.1/4" NPT Boiler Supply Product Specifications ~ ~ Trlanl::jl~Tubl~ mm] [17'6 mm] : ~,4" NVentPSoCutPbTssure RelIef Valve 3" Combust on Air Inlet 15.60' [396 mm[ 1-114" NPT Boiler Return 1-1/4" NPT Boiler Supply Side View PRESTIGE Solo 175/250 Product Specifications ~1~ Wr ! a n ~ ] ~Tu h ~ 32.0 '~. 28.0 O ~ 24.0 ~ 20.0 o ,~ 16.o 3 12.o ~ 8.0 Q. 4.0 0.0 Pressure Drop Comparison - Grundfos ~ Prestige SOLO 175 ~ Prestige SOLO 250 5 10 15 20 25 Flow Rate (GPM) Graph 4: Pressure Loss Through Boiler - Grundfos Circulators '~ 16.0 4.0~ Pressure Drop Comparison - Tac( Prestige SOLO 175 Prestige SOLO 250 Taco 0010 --'~ Taco 0011 -,~ Taco 0012 0.04 , 5 10 15 Flow Rate (GPM) Graph 5: Pressure Loss Through Boiler - Taco Circulators Note: Minimum allowable flow rate at full input: - 8 gpm SOLO 175 - 12 gpm SOLO 250 Product Specifications Trmnc leTube SOLO 60 Natural 60,000 54,000 47,000 95% 95 / 43 Propane 95% 95 / 43 SOLO 175 Natural 170,000 154,000 134,000 95% 131/60 Propane 95% 131 / 60 SOLO 250 Natural 245,000 223,000 194,000 95% 142/65 Propane 95% 142 / 65 SOLO 399 Natural 399,000 379,000 330,000 94.1% 95.1% Propane 225 / 102 Note 1: Note 2: Note 3: The heating capacity of the PRESTIGE Solo Note 4: 60/175/250 is based on the test requirements of the U.S. Department of Energy. The IBR rating is based on a piping and pick up allowance of 1.t5. This allowance should be sufficient for the standard radiation requirements for a building load. Note 5: Based on the given AFUE the PRESTIGE Solo 60/175/250 meets the energy efficiency guidelines established by Energy Star. Input and output ratings are shown for sea level applications. The PRESTIGE Solo automatically derates the input at approxi- mately 2% for every 1,000 Ft. of altitude. No alterations to the boiler or burner system is required. PRESTIGE Solo 399 output rating is based off of the thermal efficiency. 03/19/2009 11:12 631-708-S600 Z S CONTRACTING PAGE 02 I~ULGINI & BULGINI, G.C., lNG, D/WA N~LON INSULATION 9 ROBIN LANE{ CLINTON. CT 06413 P~ON~ (860) 6e~-oa~ StArE REG.,~51987 Proposal 2/24/2009 1697 Z & S CONTP, ACI'INO P^UI, CONTII,{,O P.O. BOX 202 FISHP:R~ ISLAND. NY 06390 Contractor eubmit~ Ibis ptolx~al far wo~ on the pro~orly ~rejn do~d~. U~n ~a~ Contm~r ~ ~ fum~ lu~ end mnlerlals noco~e~ 10 imp~e I~0 ~ gte~lse~ in ~ go~, workmanlike e~d eubat~hllel ~a~nor acceding to the t~rms. S~ .nd ~mp~: The ~mam sm~ da~ ~ ~ a~ appr~im8~ ~mp~n g~ of L ...... are ~J~ to JOB LOCA'IION: I.AWRI'.'NCF, R[';SI D,;,;NCI':, Iq,K11ERS I~I,A,~, ~ IIIOll Db~I'I'Y CEIJ.III~)SE ~Y~T[~ - FI~ REI'ARI)ANT, DE~RS MOl J) AND PES'~OI)F~ W~ NA~.I.Y (~UR~NG MINE~L~ AND UIGHER R-FACrOR THAN FOAM, ~ERG Y ST~ NA~ JRAI, G~EN ~CYCI,ItD PRODLJ(YF TI [A'I' PI~C(IRMS I) I S~ AND 2ND F~JR W~.[.S W['~ 1 {)RILl, AND PI.U(} MI<TI ff)D FROM ()ITl'SIDE PERIME'I~',R OF HOU~E ~) DEli J. HO{.l[q I IIGll AND I~)W ON F~{ ~y CI~R 3) INSTAl J. CLA~S { (~,',LI.ULOSE R- 15 PUl,I, VOID COV~GE 4) INSTAIJ, ~SULATED I'LUGS ~ 5) DRIL[, AND PLUG ]I IROUGI4 ~D AND 3~ F~R VAI H/IICD WIIERI~ NICICt)]C])'IZ) PIIJ, CAVITIES R-~ SOME VAUI,qI[O BLOWN ~OM 3~1) IH.(X)R A~IC 6) D~[ ~D Iq,IlO 2ND I~ I~AT CEII,IN(; ARI~ ~IAT BUMP O1~1' OF ~AIN I IO[~B R~9. AI~R()X. 2-3 IIOI,ES I) ~11,1, AND PI,UO 1~ ~],(X)E PAN~Y R~M CEILING R~9 12.5% APPROX. 3 ROWS ON EACH BAY CEdi'ER 3' APART A~ESS MAOI~ AND IN~'A~ R.I ~ NATt JRAI. UI,~ TOUCH COTI])N liar; ~ S"I'UI)S TO INSUI~'I'I~ COMIR)RT ZONE 9) INS[ Jl,A'l'l.: ALI, EZI~SED KNEEWAIJ. FI~RS ~ 12" C~SS I CI,;LI.I ll.OSE R46, AND I'I,U(} I IOI ,ES W~ TAPE~ W(ff)D ~,UGS ~ S~ OF~ HEAT IX~ PROM I~R BEI,OW 10) ~[flA~ 3~ FL~R I~%~R GABL~ W~'I~IROUGI I PI~$'H~R. DRILl, AND M~OD WH'H C~ i O~M,U[~ ~U~ HOLES WFH I INSUI .A'n~D PI,t SiS, DRILl, I Itl~ll AND LOW ON EACll BAY CISN'FER I I ) INStJE~'II~ 3RD FI~E ~,AT Ct{II.INO Wl~ { I)' CI,AS~ I C~IA.t}Lt~F. 12) IN$UI~'{I( NEW F.X~NDED 3RD FI~R ~MII~ W~ CI,ASS 1 ~ELLULOSE WI'Hi MIL ~EI~I$OR~}[I) E)LY. R,ATS R-$0 13', EXT W~.I.S R-24 Z X 6 l)) OJ(AN UP ~D VAC ~L INSUI.A~ON DEBRIS PLb~SE NOTF,: FOR EXTERIOR WALLS {W(X)D (:[,APBOARD/~I IAKI<S & O~ AI.tlMINUM ONI. Y); ~)Mlt PAI~F CI IIPPI~;, T(~I, MA~K~ AN I~OR BliNI)ING WILt. ~Ct. R WI IEN REM( )VIN(i AND RE~gTAI.LING SID~(I. Rc~'ofit Only: If cxi~ing i~sulntion is f~una, of $0.~3 I~ ~1.1~ will I~ npplhxl down f~inlmum ~ilaf$C Of ~/~ tO ee,'~f W~hou~e, Mileage and I.alx)e '~b'ts. Total ACCEPTAN~ OF PROPOSAL You, the Buyer, may eaneel thli trenllCtion at any time prior to midnight ot the thlrU ~llflell day n~or the date of VuSafeTM Installation Methods Positive Attachment NOTE: ParelMate~sed for easy installation / removal of positively attached panels. VSl-lndall-04 Posihve-6ffochrnent,dr 12/4/2006 Co~ighi~2007VuSafelndudrie~,LLC611righfs~eser~¢d. hfip://~vusafecorn 800-$22-1599 VuSafeTM Mounting Hardware PanelMate - Male PanelMate - Female Item: H1 1/4-20 thread on stud #14-10 thread on fastener 18-8 stainless steel stud hardened steel (coated) fastener Item: H2 square drive inside stud 1/4-20 thread (female) in stud #14-10 thread on fastener 18-8 stainless steel stud hardened steel (coated) fastener Washer Wing Nut Keyhole Washer Item: H8 1/4-20 thread bimetal zinc coated, polycarbonate or 30% glass filled nylon Item: H9 polycarbonate or 30% glass filled nylon Wood Screw - Flat Head Item: H3-3 Item: H3-4 square drive #14-10 thread 18-8 stainless steel Sidewalk Bolt Item: H10 1/4-20 thread 18-8 stainless steel for use with female PaneIMate (H2) Wood Screw - Pan Head 3.00" <iiiiiiiiiiiiiiiiiiiiiiiiiD 4.00" Item: H4-3 Item: H4-4 square drive #14-10 thread 18-8 stainless steel Track Nut c;'~' ~ 2.06" Item: H13 1/4-20 thread 18-8 stainless stee~ for use with Hurricane) Hook (H16) Track Bolt i ~1~ 0.12" Item: H5 1/4-20 thread 18-8 stainless stee~ for use with Ultra-FTM (785), F-Track (784A), and Panel Clip (H15) Panel ClipTM 3/8-16 thread Item: H15 polycarbonate or 30% glass filled nylon ~ use with Ultra'H rM (787) · · Patent Pending Flat Head Screw ~ 0.75" ~1~ 0 50" '~ Item: H6 square drive 1/4-20 thread 18-8 stainless steel for use with Track Nut (H13) and Hurricane Hook (H16) Hurricane HookTM ~---1.50"~ Item: H16 polycarbonate or 30% glass filled nylon Patent Pending %lvey-of-Companentscdr 5/1§/2007 Copyright C© 2007 VuSo~e Industries, LLC. All rights reserved, hHp://ww,~vusefe.com 800-522d599 VuSafeTM Storm Panel System Panel Width Worksheet Number of Panels Total Suggested Minimum Panel Width Channel Width 1 Full Panel 14.00" 15.00" 1-]/2 - 20.00" 21.00" 2 Full Panel 26.25" 27.25" 2-1/2 - 32.25" 33.25" 3 Full Panel 38.50" 39.50" 3-1/2 - 44.50" 45.50" 4 Full Panel 50.75" 51.75" 4-1/2 - 56.75" 57.75" 5 Full Panel 63.00" 64.00" ,5-1/2 - 69,00" 70.00" 6 Full Panel 75.25" 76.25" 6-I/2 - 81.25" 82.25" 7 Full Panel 87.50" 88.50" 7-1/2 93.50" 94.50" 8 Full Panel 99.75" 100.75" 8-1/2 105.75" 106.75" 9 Full Panel 112.00" 113.00" 9-1/2 118.00" 119.00" 10 Full Pa riel 124.25" 125.25" 1 O-1/2 130.25" 131.25" I 1 Full Panel 136.50" 137.50" 11-1/2 142.50" 143.50" 12 Full Panel 148.75" 149.75" 1 2-1/2 154.75" 155.75" 1 3 Full Panel 161.00" 162.00" 13-1/2 167.00" 168.00" 14 Full Panel 173.25" 174.25" 1 4-1/2 179.25" 180.25" 1,5 Full Panel 185.50" 186.50" ] 5-1/2 191.50" 192,50" 1 6 Full Panel 197.75" 198.75" 1 6-1/2 203.75" 204.75" 1 7 Full Panel 210.00" 211.00" NOTE: Example Panel Configurations One Full Panel One and One-Half Panels Two Full Panels This table is for determining Finished Width Only. **Slight variances may be experienced due to panel corrugation. SQD107.4.CDR 11/13/2007 REV-1 Copyright © 2007 VuSafe Industries htt p://www.vusa fe.com 888-232-2331 VuS, VuSafeTM Panel ~Optional Top Keyholes Bottom Keyholes Cutout Standard Survey-ot-Compo~enflzdr 5/18/2007 Copvrighf © 2007 Vu~ofe Indultries, LLC. ~11 dghh r~seryed, hftp://~v'~,.,uJafecom 800-522-1599 15.00 MAX ALL OTHER NON-CLAD APPLICATIONS CLAD APPLICATION STRUCTURAL BRACKET MAX 6.00 ! 1.094 NOTES: 1. FOR GENERAL SPECIFICATIONS. REFER TO DOC 00003952 2. PRIOR TO INSTALLATION, PREDRILL THROUGH CASING AFTER BRACKETS ARE IN PLACE 3. MAXIMUM DIMENSION FROM EACH CORNER 4. MAXIMUM DIMENSION BETWEEN BRACKETS 5.4 9/16 BRACKETS SHOWN, APPLICABLE FOR 6 9/16 BRACKETS ALSO 6. FOR 6 9/16 BRACKET INFORMATION REFER TO DOC 00038634 ,~, 7. THIS METHOD IS NOT APPLICABLE FOR INTEGRITY OR INFINITY PROI~'!,~ /~ 8. APPLY STRUCTURAL ADHESIVE TO FI,L. LER BLOCK, STAGGER TWO ~ FASTENERS MAXIMUM SPACING 15.00 [~ 4.0 ADD SUBSILL APPLICATION, NOTE8 [ 9294 10/06/08 I CRY I {~ '~ 3.0 EDIT PARTS LIST UPDATE PRINT REFERENCES I 9127 08/26/08 I CRY I ~ · 2.0 EDIT PARTS LIST ITEM 2, ADD MISSING FASTENER 8980 08/15/08 I CRY I 1.0 ADD ALL NON-CLAD APPLICATION VIEW 8381 03/19/08 I CRY I ).00RIGINALISSUE ' 7514 05/11/07 [ CRY / ~EV DESCRIPTION / REQU~-~STER ECN NO DATE [REV BY1 UNSPECIFIED TOLERANCES DECIMALS: !ANGLE DEG: XX: ± .03 ± .5 XXX:± .016 LINEAL (L/L): FAB (F/L): + NA ± NA - NA MATERIAL: NON-CLAD CASEMASTER APPLICATION STRUCTURAL BRACKET SUBSILL APPLICA~ NA #8-18 X 2.000" TYPE NTF, 2/3 THREAD *** FULL LENGTH FILLER BLOCK *** STRUCTURAL ADHESIVE 00013170 #6-18 X 2.250 FH TRIM HEAD SCREW 00003224 #8-18 x 1.500" TYPE AB, 2/3 THREAD 00022247 #8-18 X .625 TYPE NAB FULL THREAD STRUCTURAL BRACKET 4 9/16" DWG NO DESCRIPTION PARTS LIST Windows and Doors WARROAD, MN, USA, (218) 386-4021 00030644 VER 0.8 PRODUCT MARVIN WINDOWS AND DOORS CATEGORY: UNIT TYPE: ALL DWG TYPE: INSTALLATION DESCRIPTION: STRUCTURAL BRACKET INSTALL IZ2 & 173 UNITS CHK: JJSlSIZE: CLASS: I DWG NO: 10/07/08 I B ASSY I 00049070 APP: JTK SCALE: DATE: IDWG BY: SHEET: 10/07/08 2:3 05/11/07 I YLITALO, CHRIS 1 OF 1 NOTICE-CONFIDENTIAL INFORMATION. The ;,',[u--,~tiun on this drawthg is privile. ~d and stricfly confidential, it is intended solelyfortheuseoftheindividualorentitynamed above. ~fthereader~fthemessageisn~ttheintendedre~)ient~rtheemp~yee~ragent~ftheintendedmcipient~ please notifythesenderimmediatelyand then delete this drawing from all data storage devices and destroy all hard copies. Any unauthorized dissemination, distribution, copying or other use of the information contained in this drawing is sthctly prohibited. This drawing may be distributed internal to Marvin Windows and Doors on a need to know basis without prior consent. I, '¢ i pOL~ ,~ ( ] [~¢U~P2} k ~ k ~PAVED DRIVEWAY //2 k%~ 0 -6 TOPSOL % / ~ ~ ~ ~ I ~ ~'11' ~ ~ ~gr/~ ~ )' '~ ~ N~ ~ ~ '~ ~ A Major DMsion, Coarse-Grained Soils, Sand and Sandy Sails,- Clean Sand SP ~~ J X ) )~ ~ ~r]~ c ~k k~ ,/ (~ X ~ ¥ ~AY HARBOR GOLF CLUB N~ (/ , ' I ~t /(IX X 'g ) k ~ .,, % 'X~ qx I I~Xm~_X Xx ~6,- ON SITE SEPTIC SYSTEM P~N PROVIDE 3 LEACHINg POOLS (W/24" SPACER) SEE DETAIL- INLET EL~ATrONS- 560 / ..,~.*~ / ¢%% I ~ [ ~ ~~~~dn~ ~ ~ '. ' '/ X% ~ ~/ , : ~j 2,) R ,, A VlO~TION OF THE STATE EDUCATION ~W FOR ANY PERSON, UNLESS / ~ ~ ~ , ~ , ~ ~ r ~~~Q~ ~._~ x ~ ~--' I 7 ~ ACTING UNDER THE DIRECTION OF A LICENSED ~ND SURV~OR, TO ALTER AN /%~.~ ~ '~%%~,'x'X¥:X~¢'% %%%%/// -~ li~/r' SIGNATURE AND AN ORIGINAL EMBOSSED OR INK S~L ARE THE PRODUCT OF ~~,,~ ~ 5,) SITE IS iN THE TOWN OF SOUTHOLD, COUN~ OF SUFFOLK TAX MAP 1000, ~ P ~ ?~% %% k ~5-0 ' I TO GRADE~ TO GRADE~ 6,) TOTAC AR~ = ~98 6795 SF (~.56 * ACRES), CONCR~E ~ ~ v~so~ X 3~ ~ B ; ; ~ -- ~CHIMNEY ....... ~~~R~ ~k % ~ ~B ~ ~ J ' = ,' ~* ~ ~ 'R'u~'%' 'Q',,,~:~I,~ N~TED HEREON HAVE BEEN COMPILED, IN PART, FROM RECORD MAPPING ~~&"~'~l~ ~ / DE =0~ OB ~ ~ 20 [ ~ ~ ~r , SUPPLIED BY THE RESPECTIVE UT~U~ COMPANIES OR GOVERNMENTAL AGENCIES, BENCHMARK-IRON ROD/ ~ .~, X moooooo ,,~.~om - Z dOUTL~, OPEN,NGS ~~~,%%X'X ~%x',~%% X % o: ~oo oo~~ I CONTINUOUS HOT/ ~AF~:~'~' ~l'fi cio PETER LAWRENCE ~ ~0 -'~ ~ ~%%Xk '~ ~'~ k k ~ M~ ~ 24" SPACER I ~ ~, A~HAL~EAL~ EideR-WiTH ~ bJ~'. 110 FIVE MILE RIVER ROAD ~ k~/ - k~ / ~~ I lA / ) i J I '~. % X NOT TO ~CALE .,, t I ,, 11 ) 'N~ PERMANENT WATER SERVICES TO BE INSTALLED AS REQUIRED BY ~--- ]~ LUCINDA J. HE~~~ ( ( ~ [ "~ j ~A~I~ ~ ~ J ~ ~ FISHERS IS~ND WATER COMPANY, / SINGLE FAMILY RESIDENC~ x ~ ~ ~ I ~ (~ ~'~ V3 ~ ~ 0~ / MUNICIPAL W~~~~~[~ ~ k ~ ........... 12,) BABE FOR L~ELS: NGVB 1929, CAST /' X k 2000 GALLON ~~. ~ ~ -~ ~LIBER 9101, PC, 259 NOT TO SCALE O~ , CONTINUOUS HOTOT/ / BAFFLE ~~~ ~,' ',k I ~ ~ k k k ~ I ~4" SCHEDULE ~ ~ /8 PVO ~ ~ ~~m~ k:~k k ~ I ~ FF FIRST FLOOR %Ross SECTION 1000 GALLON , ~D HYD~NT '- 2 COMPARTMENT s w. WATE ATE JR. TRUST DATE: 01/05/2009 SEPTIC TANK . M NT BRUSH LINE NOT TO SCALE SINGLE FAMILY RESIDENCE v ~/ ~/ '~/ SCALE'. = WATER I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL ..... EDgE OF ~WN ~ N/F ~ ~ ON SITE SEPT/C SYSTEM AND CONSTRUCTION OF SUBSURFACE SEWAGE ~~ STONE WALL QUALI~ CONTROL CERTIFICATION ~ / / THOMAS W, ~ DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCE GROOP R~EWED ~ RUSSELL TRUST ~ ~ AND WILL ABIDE BY THE CONDITIONS SET FORTH ~ STONE RETAINING WALL PROJECT ~AGER ~ ~ SIN~L~ FAMILY RESIDENCE ~ THEREIN AND ON THE PERMIT TO CONSTRUCT, YD YARD DRAIN SHEET su.~ ~ //¢J~ ~UNCIPAL WATER ~o ~s o so ENVIRONMENT~ ON ~/T~ SEPTIC ~Y~T~M TH~ TEST HOLE C,~L ~ I~ a/dC APPLICANT G~PHIC S~E IN u --u ~KNOCKOUT INLET AND __ r,,-/ OUTLET OPENINGS RIBS INSIDE~ D /-4 x 4 126/12.6 · = .2T' / /-6 x 6 6/6 G/ WI,R,E MESI 20 INLET F'-~>---~5,; VENT/ 3" VENT~-- LIQUID L~/EL~ 4" CONTINUOUS HOT OUTLET BAFFLE 0 ASPHALT SEAL LINED WITH kr INLET BAFFLE ~ 60' BAS / QUALITY CONTROL CERTIFICATION GROUP R~IEWEO POLE N: 1528.41 ,, W: 2482.00 ~' ~ BOULDER-- BY,. R, STROUSE P,E.,LS, 12/50/08 I -(~OUND) 9"-36" SANDY SUBSOIL . ~6"-72" SANDY TELL W/FINES- SM 72"-17' SAND- LI~LE OR NO FINES- SP 5[TE ' Major Division: Co~rse-Groined Soils, Sand and Sandy Soils, Sands with Tines SM NRCS, USDA Ball Cla~siBcotlon. Riverheed and Plymouth, Ve~ bouMery soils POLE (FOUNO) DRIVEWAY 0"~ 6" TOPSOIL ~ SINGLE FAMILY RESIDENCE MUNICIPAL WATER ON SITE SEPTIC SYSTEM / / APPROX. LOGATION PAD' GARAGE/I COTTAGE f?OUNP) #2/C 24" ]AK POLE \ \ POLE HAY HARBOR GOLF CLUB MUNCIPAL WATER ON SITE SEPTIC SYSTEM OVERHANG 6" WATER M~N (APPROX. LOCATION) PARKING EXISTING ~'i HIGH RETAINING WALL BENCHMARK-IRON ROD ELEVATION =76.49 OARDEh TRELLIS CONCRETE \/~CHERRY CROSSOVER N/F LUCINDA J. HERRICK SINGLE FAMILY RESIDENCE MUNICIPAL WATER ON SITE SEPTIC SYSTEM 18" ~ '~MONUMENT (NOT ~cow~-p) AREA OF BOULDERS BENCHMARK-IRON ROD ELEVA~ON =42,59 \ \ CHERRY 28" TWIN CHERRY TWIN CHERRY BOULDER N/F THOMAS W. RUSSELL TRUST SINGLE FAMILY RESIDENCE MUNCIPAL WATER ON SITE SEPTIC SYSTEM 24"-17' SAND- LITTLE OR NO FINES- BP Unified Soils ClossificoDon (USC) System (from ASTM D-2487) Major Divlsion'. Coorse-Orolned Soils, Sand and Sandy SOILS,- CJeon Sand SP NRCS, USDA Boll Clossfflcotlom RIverheod and Plymouth, Very bouldery soils S~'P~C SY~M DESIGN FOR S SEDROOM RESIDENCF 200[3 GALLON SEPTIC TANK- SET AT EXISTNG PIPE ELEVATION 1 DISTRIBUTION BOX S LEACHING POOLS- 6' X 8' N: 606.54 W: 2159.55 20' UTILR¥ EASEMENT 9101~ PG, 259 18" 455.22 W: 2057.49 ~/F THOMAS W, \ RUSSELL JR. TRUST \ AGREEMENT SINGLE FAMILY RESIDENCE MINCIPAL WATER ON SITE SEPTIO SYSTEM \ \ [ AM FAMILIAR WITH THE STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCE AND WILL ABIBE BY THE CONDITIONS SET FORTH THEREIN AND ON THE PERMIT TO CONSTRUCT. APPLICANT LOCATION MAP SCALE 1"=4.O0' %) PROPOSED LOT LINE CHANGE PROPERTIES OF ELIZABETH F, HUSBAND AND OUNTHER STROTHE & LUCfNDA J, HERRICK OCEAN VIEW AVE, & HEATHULIE AVE. FISHERS ISLAND, NEW YORK. BATE: JANUARY 05, 2000 SOALE', 1"--1D0' SHEET ~ DF 1, BY CPK CHANDLER, PALMER & KING, %) THiS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED HEREON, ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE ENGAGEMENT, 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACT[NO UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO ALTER AN I;'EM IN ANY WAY. 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR'S SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF ]HE LAND SURVEYOR. 4,) COORDINATE DISTANCES ARE MEASURED FROM U,S, COAST AND GEODETIC SURVEY TRIANGULATION STATION "PROS", .",) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000, EECTION 009~ BLOCK 11, LOT 7,12, E,) TOTAL AREA = 198,679J: SF (4-.56 :k ACRES), ),) SITE IS LOCATED IN R-BO z_ONE, 8,) UNDERGROUND UTILITY, STRUCTURE AND FACIUT7 LOCATIONS DEPICTED AND NOTED HEREON HAVE BEEN COMPILED, IN PART, FROM RECORD MAPPING EUPPLIE5 BY THE RESPECTIVE UTILITY COMPANIES OR GOVERNMENTAL AGENCIES, FROM PAROL TESTIMONY AND FROM OTHER SOURCES, THESE LOCATIONS MUST BE CONSIDERED AS APPROXIMATE, ADDITIONALLY, OTHER SUCH FEATURES MAY EXIST ON THE SITE, THE EXISTENCE OF WHICH ARE UNKNOWN TO CME ASSOCIATES~ [NC, 9.) OWNER/APPLiCANT: HIGHLAND HOUSE FI, LLC C/O PETER LAWRENCE 110 FIVE MILE RIVER ROAD DARIEN, CT 06820 205-552 ~0444 10,) SITE IS SERVICED BY MUNICIPAL WATER AND ON SITE SEWAGE DISPOSAL SYSTEMS, 11.) NEW PERMANENT WATER SERVICE INSTALLED AS REQUIRED BY FISHERS ISLAND WATER COMPANY, 1~2,) SASE FOR LEVELS: NGVB 1929, FF N/F SF SYD WG FIRST FLOOR OVERHEAD UTILITIES NOW OR FORMERLY SQUARE FEET WATER VALVE HYDRANT WATER GATE BRUSH LINE EDGE OF LAWN STONE WALL STONE RETAINING WALL YARD DRAIN TEST HOLE 50 25 0 50 GRAPHIC SCALE IN FEET SCALE: SHEET 1 OF1 / / ./ rr la w,~¥ ¸',% KEY PLAN KINLIN RUTHERFURD ARCHITECTS. 330 WEST 38TH STREET, SUITE 1006 TEL (212) NEWYORK, NEWYORK 100Z8 FAX (775) CHRISTOPHER KUSSKE, ASL LANDSCAPE ARCHITECTURE 81TE PLANNING GARDEN DESIGN 2~ CUDLIPP STREET ROWAYTON, CT 0~853 203. 838.5860 FAX 203.854.9456 CAKCT ~AOL.COM LAWRENCE RESIDEg Fishers Island, NY LAYOUT and GRADING DATE. June2,2009 SCALE'1"=10'-0" JUL 21 2009 8LDG OEP[ L-1 6 EPVC PIPE /CPVC PIPE gTRRP HEX HEED gELF HANGERDETAIL NOT TO SCALE HANGER DETAIL STEEL PIPE STRAP PIPE STRAP NOT TO SCALE THIS DRAWING IS PREPARED BY LIBERTY MECHANICAL FOR USE IN CONNECTION WITH THIS PROJECT FOR USE SOLELY WITH REBPECT TO LIBERTY MECHANICAL'S WORK ON SUCH PROJECT. LIBERTY MECHANICAL RETAINS ALL COMMON LAW, STATUTORy AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT. THE DRAWING SHALL NOT BE USED BY OTHERS ON OTHER PROJECTS OR FOR PERFORMANCE, COMPLETION, OR ADDITION TO THIS PROJECT BY OTHERS EXCEPT BY AGREEMENT OF LIBERTY MECHANICAL IN WRITING AND WITH APPROPRIATE COMPENSATION TO LIBERTY MECHANICAL, ITH 3D, lET 3D. DOWN KITCHEN O TV ~OM POWD~;~ 0 LIVLNO O SOUTH PORCH DIh WG 0 0 DINrNG PORCH FIRST FLOOR SUN P~OM Ill l EXISTING 1" up - DOUBLE O UTILITY SINK TO REMAIN FROM SPRINKLE AIR HANDLER BASEMENT CRAWL SPACE B B SPRINKLER PATH FROM BATH 6 TO DOOR E103 ON FIRST FLOOR RECESSED SPRINKLERS TO COMPLY WITH NEW YORK RESIDENTIAL CODE A J604 AND NFPA 13D UNFINISHED l" UP & STO, DOWN UNFINISHED STO. THIRD FLOOR SPRINKLER PATH FROM BATH 5 TO DOOR E103 ON FIRST FLOOR, RECESSED SPRINKLERS TO COMPLY WITH NEW YORK RESIDENTIAL CODE AJS04 AND NFPA 13D BEDROOM 2 2NO LOC H~L ~) [] 0 BEDROOM 5 BEDRi~0M 4 SECOND FLOOR UNFINISHED STD. UNFINISHED STO, BALCONY RESIDENTIAL NOTES: AS PER NFPA 13D TABLE 7 55,3 MINIMUM DISTANCES FOR ORDINARY AND INTERMEDIATE TEMPERATURE RESIDENTIAL SPRINKLER8 HEATSOURCE MINrMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY-TEMP SP[]NKLER SIDE OF OPEN OR RECESSED FIREPLACE 36" FRONT OF RECESSED FIREPLACE 50" COAL OR WOOD BURNING STOVE 42" srBE OF CEILING OR WALL MOUNTED NOT AIR DIFFUSERS 24" HOT WATER HEATER OR FURNACE [] SI~ING WATER SUPPLY RrSER MAST~t BEDROOM [] CLO, N ~.W i"~ iLO,, WA-~L.- ', 4 '% 50 UTH e~TAli~-~ .) KINLIN RUTHERFURD AR: CI-IgJJSTOPHER LANDSCAPE ARCH SITE PLANN GARDEN DE; 23 CUDLiPP G- ROWAYTON, C;' 203. 838.5860 FAX 2 LAWRENCE R I Fishers Islan SITE DE1 DATE: June SCALE: As L-; -r _-'~/<~t~ ~ SATe- + qE',~a T~ FAVI NC __ 7Z I''¢ ('~0" KINLIN RUTHERFURD ARCHITECTS, PLLC 330 WEST 28TH STREEr, SUITE ~006 TEL (212) 695-2988 NEW YORK, NEW YORK ~00~8 FAX: (775) 582-~736 CHRISTOPHER KUSSKE, ASIA LANDSCAPE ARCHITECTURE SITE PLANNING GARDEN DESIGN 23 CUDLIPP STREET ROWAYTON, CT 06853 203. 83815860 F~X 203,854l~456 CAKCT ~OL.COM LAWRENCE RESIDENCE Fishers Island, NY SITE DETAILS DATE: June 2, 2009 SCALE: As Shown Revisions: L-3 ! -I KINLIN RUTHERFURD ARCHITECTS, PLLC 330 WEST 38TH STREET, SUITE 1006 TEL (212) 695-2958 CHRISTOPHER KUSSKE, ASLA LANDSCAPE ARCHITECTURE SITE PLANNING GARDEN DESIGN 23 CUDLIPP STREET ROWAYTON, CT 06853 203. 838.5860 FAX 203.854.9456 CAKCT ~AOL COM LAWRENCE RESIDENCE Fishers Island, NY SITE DETAILS DATE; June 2, 2009 SCALE. As Shown Revisions: L-4 SHEET LOG ISSUED SHEET X A001 X A021 X A101 X A201 X A202 X A204 X A401 X A402 X S'fO0 X S101 X S102 X S103 DESCRIPTION TITLE SHEET SITE PLAN FIRST FLOOR CONSTRUCTION PLAN EXTERIOR ELEVATION EXTERIOR ELEVATION EXTERIOR ELEVATION WALL SECTIONS WALL SECTIONS STRUCTURAL PLANS STRUCTURAL PLANS STRUCTURAL PLANS STRUCTURAL PLANS HIGHLAND HOUSE FISHERS ISLAND NEW YORK TAX MAP: 1000 SECTION:9 BLOCK :11, LOT 7,12 PERMIT SET AMENDMENT 11. PERMIT SET 03. REVISION ISSUE DA~= HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, TITLE PAGE PROJECT: 127 AO0: PROVID~ ~EACHIN¢ POOLS, (SEE DETAIL ~BEENCHMARK-IRON ROD LEVATION :76.49 PROVIDE PIPES ' 'F ,",OFI F IZI' F' ,I-'LIEE, , I_, F'l: IZl,'n7 PRDVIDE I # w ,' ACRE~S~· LEACHIN~POOLS i %~, ( SEE ,m~_'LmCTA] E) ,, ,, £ ,'O" &,2J £¢ IIIILITi EAZ, EIIIIIT (NOT ~_cove~eo) ~bo. . - ~. _. , BENCHMARK-IRON ~OD ELEVATION =42.39 r ~ THOt~i~'- i' 455 22' Ol SITE PLAN PERMIT SET AMENDMENT 11.03.09 PERMITSET 03,19.09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC SITE PLAN PROJECT: 127 A021 NOTES 1 ALL EXTERLOR WALLS TO RECEIVE NEW WOOD SHINGLES. 2, ALL EXISTING WALLS AND CEILLNGS TO BE PATCHED, SKIMMED AND CLEANED, AS REQUIRED. 5, ALL SURFACES TO BE REPAIRED AND REFINISHED, AS REQUIRED, NEW COPPER DOWNSPOUT NEW HOSE BIB NEW REPLACED TOILET NEW REPLACED LAVATORY NEW COLUMN, TO MATCH EXISTING ON EAST PORCH KITCHEN PORCH FLAT ROOF TO BE RE FRAMED AS SHOWN, NOTE: NEW OUTDOOR SHOWER LOCATION TO BE DETbRMINED. SLOPED CONCRETE SLAB WITH DRAIN, LEADING TO DRYWELL LOCATION OF DRYWELL TO BE DETERMINED SPRINKLER PATH FROM DOOR E105 TO BAFN 6 ON SECOND FLOOR RECESSED SPRINKLERS TO COMPLY WITH NEW YORK RESIDENTIAL CODE AJ604 NEW DISHWASHER NEW MICROWAVE NEW RELOCATED SINK NEW COUNTER AND CABINETS NEW REPLACED RANGE II REFRIGERATOR IF STAIR FO BE RE-FRAMED NEW 1" IPE TREADS AND AZEK RISERS EW BALUSTRADE, TO MATCH EXISTING INSTALL NEW WINDOW NEW PROPANE GRILL WITH DIRECT NEW WASHER AND DRYER RELOCATED DOOR NEW HOSE BIB INSTALL NEW CABINETRY AS SHOWN INSTALL NEW DUTCH DOOR TO MATCH EXISTING DOOR IN DINING ROOM III III I% EXISTING BEAM TO REMAIN AND TO BE BOXED OUT AS SHOW~ KITCHEN (E IO'}i STAIR HALL PANTRY REFURBISH AND REFINISH ' EXISTING WINDOW INSTALL NEW BALUSTRADE, MATCH EXISTING DINING PORCH REFURBISH NEW COPPER DOWNSPOU]TS 01/A202 NEW HOSE BIB ~ TV ROOM REPLACED I"IPE TREADS AND AZEK RISERS REFURBISH AND REFINISH EXISTING WINDOWS POWDER ROOM 1ST FLOOR I I HALL I CONSTRUCTION LEGEND NEW WALLS EXISTING WALLS TO REMAIN EXHAUST VENT SMOIKE DETECTOR/ CARBON MONOXIDE DETECTOR REFURBISHED EXISTING LAVATORY NEW REPLACED TOILET REFURBISH AND REFINISH EXISTING WINDOW 1 LIVING SOUTHf PORCH NEW COPPER DOWNSPOUT AT STONE COLUMN NEW HOSE BIB NEW STAIR AT SOUTH PORCH. NEW STONEWORK AND TREAD TO MATCH NEW STAIR AT SUNRO, NEW I"IPE TREAE AND AZEK RISEF SUN ROOM NEW COPPER DOWNSPOUT AT STONE COLUMN 115 :INISH NDOW 01/A204 NEW 1" IPE TREADS AND AZEK RISERS RECONSTRUCTED SOFFIT AND TRIM DETAILING TO MATCH EXISTING NEW WINDOW & FRENCH DOOR SYSTEM WITH INTEGRATED COLUMNS AT SUN ROOM NEW STAIR AT SUN ROOM. NEW STONEWORK AND TREAD DETAILING fO MATCH NEW STAIR AT SOUTH PORCH, 0 1 PROPOSED 1ST FLOOR PLAN 1~ NEW SHINGLES WILL BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS 2, NEW COPPER HALF ROUND GUTTERS, WNERE SHOWN, WITH NEW COPPER DOWNSPOUTS. 5, ALL EXTERIOR WOODWORK TO BE REFINISHED AND REPAINTED, 4. CHIMNEY FLASHING REPAIRED/REPLACED AS NECESSARY. ,,-, T.O RIDGE '" ELEV 50'11" NEW ORIEL BAY WITH EGRESS WINDOWS BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE, RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW QN EAST FACADE, DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBLE CASEMENT WINDOW #2,32 ON WEST FACADE. ., T.O FINISH FLOOR ELEV 19'10" $ %0 FINIBH FI.OOB ELEV 10'7' -- I NEW' SECOND FLOOR BALLUSTRADE TYP. TO MATCH EXISTING AT FIRST FLOOR PERMIT SET AMENDMENT 11.03.09 PERMIT SE[ 03,19.09 I~SUE DATE HIGHLAND HOUSE FISHER9 ISLAND, NEW YORK ELEV. o'o" NEW 2" BLACK METAL HANDRAIL AT ALL EXTERIOR STAIRS TYP. REPAIR AND ALTER STRUCTURAL. FRAMING AND FINISH WOODWORK AT KITCHE[N PORCH NEW LATTICE PANELS TO MATCH EXISTING NEW LATTICE DOORS NEVW STAfR AT SUN ROOM , NEWt STONEWORK AND TREAD DETAILING / TO IMATCH NEW STAIR AT SOUTH PORCH. r KINLIN RUTHERFURD ARCHITECTS, PLLC 01 NORTH ELEVATION NORTH ELEVATION A201 PROJECT: 127 1. NEW SHINGLES WILL BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS. 2 NEW COPPER BALF-ROUND GUTTERS, WHERE SI-IOWN, WITH NEW COPPER DOWNSPOUTS 5, ALL EXTERIOR WOODWORK TO DE REFINISHED AND REPAINTED. CHIMNEY FLASHING REPAIRED/REPLACED AB NECESSARY, RIDGE ELEV, 50'11" NEW ORIEL BAY WITH EGRESS WINDOWS. BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBLE CASEMENT WINDOW #252 ON WEST FACADE. T,O FINISH FLOOR ELEV, 19'10" NEW SECOND FLOOR BALLUBTRADE TYP. TO MATCH EXISTING AT FIRST FLOOR $ TO FINISH FLO0 ELEV 10'}~ z TO FINISH FLOOR ELEV. 0'6)" NEW 2" BLACK METAL HANDRAIL AT ALL EXTERrOR STAIRS TYP NEW SECOND FLOOR BALLUSTRADE TYP, TO MATCH EXISTINO AT FIRST FLOOR REPAIR AND ALTER STRUCTURAL FRAMING AND FINISH WOODWORK AT KITCHEN PORCH. NEW LATTICE PANELS TO MATCH EXISTING PERMIT SET AMENDMENT 1~,.03.09 PERMITSET 03,19.09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC t EAST ELEVATION EAST ELEVATION PROJECT:&27 A202 1, NEW SHINGLES WILE BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS, 2, NEW COPPER HALF ROUND GUTTERS, WHERE SHOWN, WITH NEW COPPER DOWNSPOUTS, 5, ALL EXTERIOR WOODWORK TO BE REFrNIBNED AND REPAINTED, ~- CRIMNEY FLASHING REPAIRED/REPLACED AS NECESSARY NEW DORMER TO MATCH EXISTING, TRIM DETAILING AND FINISH TO MATCH EXISTING ..-, TO RIDGE '" ELEV, .30'11" NEW ORIEL BAY WITH EGRESS WINDOWS BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW DN EAST FACADE. RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBLE CASEMENT WINDOW #232 ON WEST FACADE. ~ T.O FrNrSH FLOOR NEW SECOND FLOOR BALLUSTRADE TYP TO MATCH EXISTING AT FIRST FLOOR TO FINISH FLOOR ELEV 10'7" REPAIR AND ALTER STRUCTURAL FRAMING AND FINISH WOODWORK AT KITCHEN PORCH. NEW LATTICE PANELS TO MATCH EXISTING. NEW RAILS TO MATCH EXISTING. FLO0 ELEV. NEW iNSWING DUTCH B)OOR TO MATCH EXISTING DUTCIH DOOR AT DINING ROOIWl NEW CUSTOM INSWING FRENCH DOORS WITH SCREENS NEW WOOD COLUMNS TO MATCH EXISTIING, WITH NEW STONE BASES TO MATCH EXISTIN(8 NEW STAIRS AT SUN ROOM AREA OF NEW STONEWORK FOR NEW FRENCH DOORS AND STAIRS NEW SECOND FLOOR BALLUSTRADE TYP TO MATCH EXrSTINO AT FIRST FLOOR CORNICE AND DENTILS TO BE REPLACED/REPAIRED AS NEEDED NEW BEAM, HEADERS, AND CASINGS NEW CUSTOM-BUILT CASEMENT BAY WINDOWS AT SUN ROOM NEW WOOD COLUMNS TO MATCH EXISTli~ MODIFY EXISTING STONE BASE TO NEW COLUMN LOCARONS 01 WEST ELEVATION P£RMIT SET AMENDMENT 11.03.09 PERMITSET 03.19.09 REVISION ISSUE DATE HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC WEST ELEVATION A204 PROJECT: 127 COPPER TILE ROOF MOULDINGS AND TRIM TO MATCH EXISTING DETAILS FASCIA BOARD TO MATCH AND ALIGN WITH EXISTIND (3) 2" X 12" SEAM RE-FRAME CURVATURE TO MATCH EXISTING 2" X 10" PRESSURE TREATED RAFTER EXISTING FRAMING "U CEDAR SIDING BUILDING PAPER ON ~" SHEATHING 2 X 12 PRESSURE TREATED FLOOR JOIST 2 X 10 PRESSURE TREATED SOLE PLATE TRIM BOARD AND BOARD CAP TO MATCH AND ALIGN WITH EXISTING 2 X TBD RIM JOIST MAINTAIN 1" GAP BELOW SIDING 6" STONE VENEER CONCRETE ANCHOR BOLT 8" CMU ,I LAUNDRY ROOM L 2"X 12" PRESSURE TREATED JOIST EXISTING STONE FOUNDATION WALL EXISTING FRAMING BASEMENT 10" CONCRETE-- FOUNDATION WALL CONCRETE FOOTING -J- 1 BUILDINIGSECTION ATKITCHEN PORCH/LAUNDRY NOTES 6" X 6" POST IS NOT TO BE CENTERED ON BEAM ABOVE (SEE FRAMING PLANS) 2. ROUND COLUMN IS TO BE CENTERED ON BEAM ABOVE, 3. TOP FASCIA HOARD IS TO ALIGN WITH EXISTING FASCIA BOARD, SIDING TRIM BOARD IS TO ALIGN WITH EXISTING SIDING TRIM BOARD 2" X 10" RAFTER COPPER TILE ROOF ASPHALT ROOFING PAPER ON SHEATHING ~" PLYWOOD SHEATHING WI TH MOULDINGS DETAILS TO MATCH AND ALIGN WITH EXISTING DETAILS FASCIA BOARD TO MATCH AND ALIGN EXISTING FASCIA BOARD (5) 2" X 12" BEAM ROUND TAPERED COLUMN TO MATCH EXISTING AT EAST SERVICE PORCH % §" X 6" POST AIR GAP SECTION DETAIL AT KITCHEN PORCH BEAM/COLUMN 03,,/,.=,. o. 2" X 10" RAFTER COPPER TILE ROOF ASPHALT ROOFINO PAPER ON SHEATHING ~" PLYWOOD SHEATHING---- WI TH MOULDINGS DETAILS TO MATCH AND ALIGN WITH EXISTING DETAILS FASCIA BOARD TO MATCH AND ALIGN EXISTING FASCIA BOARD (5) 2" X 12" BEAM ROUND TAPERED COLUMN TO MATCH EXISTING AT EAST SERVICE PORCH ! '% I I I I I I I 6" X 6" POST INSIDE ROUND COLUMN 2 SECTION DETAIL AT KITCHEN PORCH BEAM COPPER TILE ROOF MOULDINGS AND TRIM TO MATCH EXISTINB DETAILS FASCIA BOARD TO MATCH AND ALIGN WITH EXISTING ($) 2" X 12" SEAM COLUMN TO MATCH EXISTING COLUMN ON SERVICE EAST PORCR E" X 6" PRESSURE TREATED POST INSIDE ROUND COLUMN NEW RAILING 2" X 12' PRESSURE TREATED JOIST 1" X 4" IPE DECKING BOARDS (2) 2" X 12" RiM ,JOIST AZEK RISER 2" X 14" PRESSURE TREATED STRINGER ,,L RE FRAME CURVATURE TO MATCH EXISTING 2" X 10" PRESSURE TREATED RAFTER EXISTING FRAMING KITCHEN PORCH WATERPROOFING MEMBRANE EXISTING STONE FOUNDATION WALL EXISTING FRAMING EXISTING 1 BUILDING SECTION AT KITCHEN PORCH/LAUNDRY CONCRETE FOOTING CONCRETE FOUNDATION WALL ABOVE STONE WALL ABOVE CONCRETE FOOTING q 3'Xl185' 1 52 CONCRETE -- FOOTING CONCRETE FOUNDATION WALL ABOVE STONE VENEER ABOVE 90~ EXISTING STONE FOUNDATION WALL 1 FOOTING PLAN AT KITCHEN PORCH/LAUNDRY PERMIT SET AMENDIV PERMIT SET HIGHLAND HOUSE KINLIN RUTHERFURD ARCl FOOTING PLAN PROJECT: 127 CONCRETE PIER 6' X 6" PRESSURE TREATED POST CONCRETE FOOTING BELOW 6" X 5" PRESSURE TREATED POST CONCRETE PIER CONCRETE CONCRETE FOOTING BELOW 6" STONE VENEER 10" CONCRETE FOUNDATION WALL C(ONCRETE FOOTING TO BE BUILT BY Z a S CONTRACTING STONE WALL TO BE BUILT BY LANDSCAPE STONE CONTRACTOR , 1 52 FOUNDATION WALL 4'=118} '~ 5 28 I , 5,, 9 6~ 6", 4' 5? II ' L 11'-1185'' ALIGN STEEL PINS TO C(ONNECT NEW FOUNDATION TO OLD FOUNDATION FURNIACE IN-TAKE PIPE FURNIACE EXHAIUST PIPE EXISTING STO)NE FOUNDATION WALL GAS DRYER N£NT 1 FOUNDATION PLAN AT KITCHEN PORCH/LAUNdRY PRESSURE TREATED RIM 301ST 2" X 14" PRESSURE TREATED STRINGER LEDGER BOLTED TO EXISTING FOUNDATION (2) 2" X 8" PRESSURE ~ TREATED RIM JOIST 6"X 6" PRESSURE TREATED POST PRESSUt~ )TREATED2"X 8" RIM JOIST 2" X 8" PRESSURE TREATED JOIST (1) 2"X 12" PRESSVRE TREATED RIM JOIST 6"X 6" PRESSURE TREATED POST BELOW (2) 2" X 12" , PRESSURE TREATED RIM JOIST RIM JOIST I X8' TREATED JOIST I I ' 4" X '¢" RAILING POST ABOVE 2" X 12" PRESSURE TREATED JOIST 2" X 12" PRESSURE TREATED JOIST PERMIT SET AI~ PERMIT SEf HIGHLAND HOIJ KINLIN RUTHERFURD FRAMING PLAN AT KITCHEN PORCH/LAUNDRY 01 FRAMING PL, PROJECT: 127 RE FRAME ROOF CURVATURE TO MATCH EXISTING (3) 2" X 12" SEAM 6" X 6" PRESSURE TREATED POST BELOW (3) 2" X 12" BEAM (1 2" X TBD PRESSURE TREATED RIM JOIST 4" X 6" POST BELOW (5) 2"X 12" BEAM ' I 2" X 10" PRESSURE TREATED RAFTER , ! 1 ROOF FRAMING PLAN AT KITCHEN PORCH/LAUNDRY EXISTING FRAMING SHEET LOG ISSUED SHEET X A001 X A021 X A030 X A031 X A032 X A033 X A034 X Al00 X A101 X A102 X A103 X A104 X A201 X A202 X A203 X A204 X A501 X A502 X S101 X P101 DESCRIPTION TITLE SHEET SITE PLAN BASEMENT DEMOLITION PLAN FIRST FLOOR DEMOLITION PLAN SECOND FLOOR DEMOLITION PLAN THIRD FLOOR DEMOLITION PLAN ROOF DEMOLITION PLAN BASEMENT CONSTRUCTION PLAN FIRST FLOOR CONSTRUCTION PLAN SECOND FLOOR CONSTRUCTION PLAN THIRD FLOOR CONSTRUCTION PLAN ROOF CONSTRUCTION PLAN EXTERIOR ELEVATION EXTERIOR ELEVATION EXTERIOR ELEVATION EXTERIOR ELEVATION WINDOW SCHEDULE DOOR SCHEDULE STRUCTURAL DIAGRAM RISER DIAGRAMS OC{ , , 'IFICATE PLUM~BE~'C, ER.TIFfC..~ T[ ~)'V ON'LEAD, CONT. Etr , SOLDER LI' CERTIFICATION OF / NAILING & CONNECTIONS REQUIRED~. ~ ALL CONSTRUCTION SHALL MEET THE REQUIRI:~/ENTS OF THE~ CODES OF NEW YORK STATE, PERMITSET 03,06,09 HIGHLAND HOUSE qTO~M WATER RUNOFF CHAPTER 236 HIGHLAND HOUSE FTSHERS ISLAND NEW YORK TAX MAP: 1000 SECTTON:9 BLOCK :11, LOT 7,12 KINLIN RUTHERFURD ARCHITECTS, PLLC TITLE PAGE AO01 PROJECT: 127 (NOT ' ~ (SEE DBTAI[ !1 i l, l' /' I,-BENCHMARK-IRON ROD ' ELELEVA TtON = 76.4-9 PROVIDE &" CRO PIPES i -FE~ ' ,F T~' RE FF ZEFI I,FL' Till P ZF'k'IT ~OT 7.!2 '~/ 198,679J~,~F '- 4.~S~: ACRESf II Ii , , ," ZL:-I ' (FOUND) 1 SITE PLAN PERMITSEr REVISION ISSUE HIGHLANB HE FISHERS ISLAND, NEW YORK KINLIN RUTHERFU SITE PLAN PROJECT: 127 GENERAL NOTES: REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK AND APPLIANCES DEMOLITION LEGEND I EXISTING WALLS TO REMAIN __ '--'1EXISTING WALLS TO BE BEMOLISHED III I F- BOILER HANDLER CRAWL SPACE PERMITSET HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITE¢ 1 BASEMENT DEMO PLAN BASEMENT DEMO PLAN AO PROJECT: 127 I 1. SAVE & LABEL ALL FIXTURES, FITTINGS, HARDWARE, LIGHTS, BRACKETS, AND DOORS THAT ARE REMOVED FOR POSSIBLE RE-USC 2 REMOVE ALL EXISTING EXTERIOR WOOD SHINGLES. 3. EXISTING WINDOWS TO BE REPLACED UNLESS OTHERWISE NOTED. REMOVE AND SAVE BRACKETS AT KITCHEN SHELVES REMOVE HEARTH AT FIREPLACE NEW WOOl] FLOOR TO MATCH EXISTING. REMOVE LATTICE REMOVE ALL EXISTING APPLIANCES, FIXTURES, CABINETRY, LIGHTING, & FLOOR TILES IN KITCHEN. WAINSCOTING IN KITCHEN WILL REMAIN ~ NEW WAINSCOTING WILL BE ADDED AS HEEDED TO MATCH. REPLACE EXISTING ~ TOILET AND LAVATORY PORCH POWDER ROOM KITCHEN / PORCH / L_ REMOVE EXTERIOR PORCN DECKINg MATERIAL & STAIR TREADS, REMOVE & PREPARE TO REPAIR ANY FAILING STRUCTURAL MATERIAL BELOW DECKS, COMPLETELY REMOVE EXISTING AREA OF PORCH AND RAILING . \ IIIII MUD ROOM REMOVE OUTDOOR SNOWER AND PLUMBING REMOVE EXISTING AREA OF PORCH AND RAILING REMOVE ~ SA'V~ DOOR AND SCREEN TO BE RE-HUNG WITH REVERSE SWINg KITCHEN REMOVE & SAVE DOOR TO BE RE BUNG WITH REVERSE SW/NO II / REMOVE EXIS~NG REFRIGERATOR LQ. OlO Oll REMOVE EXTERIOR PORCH DECKING MATERIAL & STAIR TREADS, REMOVE & PREPARE TO REPAIR ANY FAILING STRUCTURAL MATERIAL BELOW DECKS. REPLACE EXISTINg TOILET REMOVE EXISTING SNELF EXISTING SINK TO REMAIN STONE COUNTER & BACKSPLASEI TO BE REFURBISBED. J PORCH PANTRY --REMOVE [EXISTING WINDOW ~ CREATE kNEW OPENING FOR DOOR DINING PORCH REMOVE EX(TERIOR PORCH DECKLNG MATERIAL & STAIR TREADS, REMOVE & PREPARE TO REPAIR AfNY FAILING STRUCTURAL MATERIAL BELOW DECKS. TV ROOM __. , 1BT FLOOR HALL DINING REMOVE CHAIR RAIL & WOOD PANELING BELOW THROUGHOUT DINING ROOM II ROOM REMOVE ADDED RAIL AT MAIN STAIR LIVING DEMOLITION LEGEND EXISTING WALLS TO REMAIN EXISTING WALLS TO BE DEMOLISHED REMOVE EXTERIOR PORCH DECKING MATERIAL & STAIR TREADS REMOVE & PREPARE TO REPAIR ANY FAILING STRUCTURAL MATERIAL BELOW DECKS. SOUTH PORCH REMOVE SECTION OF STONE WALL TO ACCOMMODATE DOUBLE DOOR AND NEW STAIR . RECONSTRUCT SOFFIT, TRIM, DENTILS, AND CORNICE DETAILS WHERE NECESSARY. PREP FOR NEW BEAM AND READERS AT WINDOWS AND NEW FRENCH DOORS, PERMIT SET 03.06.09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITEC3'S, PLLC REMOVE EXISTING WINDOWS, FRAMES AND SILLS AS SHOWN 11ST FLOOR DEMO PLAN FIRST FLOOR DEMO PLAN PROJECT: 127 A031 GENERAL NOTES' SAVE & LABEL ALL FIXTURES, FITTINGS, HARDWARE, LIGHTS, BRACKETS, THAT ARE REMOVED FOR POSSIBLE RE USE. REMOVE ALL EXISTING EXTERIOR WOOD SHINGLES, EXISTING WINDOWS TO BE REPLACED UNLESS OTHERWISE NOTED. AND DOORS DEMOLITION LEGEND EXISTING WALLS TO REMAIN EXISTING WALLS TO BE DEMOLISHED REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF & SAVE TUB TO BE RELOCATED IN TNB BATH REMOVE & SAVE DOOR TO SE RE-HUNG WITH REVERSE SWING AT MASTER BATHROOM REMOVE CABINET ALL BEAD BOARD TO REMAIN & NEW BEAD BOARD TO BE ADDED TO MATCH AS NECESSARY EXISTING SINK TO REMAIN. STONE COUNTER & BACKSPLASN TO BE REFURBISHED. ALL BEAD BOARD TO REMAIN & ~ EXISTING TUB TO NEW BEAD BOARD TO BE ADDED TO ~ REMAIN MATCH AS NECESSARY ~ REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF EXISTING TUB TO REIMAIN BATH 4~'~ it.... CLO, SWAP EXrSTING DOORS BEDROOM 5 EXISTING WINDOW / II TO REMAIN ', BA~H 2 CLO. CLO BEDROOM 2 EXISTING WINDOWS TO REMAIN DALCONY 2ND FLOOR SWAP EXISTINGI DOORS HALL CLO U~;L°' ;L -- ' =/ REMOVE & SAVE DOOR TO BE RELOCATED BEDROOM 3 EXISTING WINDOW TO REMAIN SWAP EXISTING DOORS BEDROOM REMOVE & SAVE DOOR TO BE RELOCATED SITTING ROOM / REMOVE ALL FINISHES & FIXTURES I RELOCATE TUB A~qD LAVATORY. REPLACE TOILET, MASTER BEDROOM ~J REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF LI CLO 12ND FLOOR DEMO PLAN PERMIT SET 03,06.09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC SECOND FLOOR DENIO PLAN A032 PROJECT: 127 GENERAL NOTES: SAVE & LABEL ALL FIXTURES, FITTINGS, HARDWARE. LIGHTS, BRACKETS, AND DOORS THAT ARE REMOVED FOR POSSIBLE RE UBE 2 REMOVE ALL EXISTING EXTERIOR WOOD SHINOLES, 3 EXISTING WINDOWS TO BE REPLACED UNLESS OTHERWISE NOTED DEMOLITION LEGEND I EXISTIN6 WALLS TO REMAIN __] EXISIqNG WALLS TO BE DEMOLBtlED REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF REMOVE EXISTING ROOFINO MATERIAL AT FLAT ROOF UNFINISRED BTO, REMOVE DOOR BEDROOM 6 ~BEDROOM 7 / CLO, I1"I" II II II, II 3RD FLOOR ,,--REMOVE & SAVE DOORS HALLWAY /' TO BE RELOCATED UNFINISHED STO -- CREATE ROOGH OPENINC~ FOR NEW ATTIC DOOR ' REMOVE ALLFINISHES & RXTURES UNFINISHED REMOVE A SAVE BUILT-IN STO, C,ADNET TO BE RELOCATED <A RE USED IN NEW BATH -] PREPARE CEILING FOR NEW DORMER REMOVE & SAVE BOOR TO BE RELOCATED BEDROOM B NEW OPENING TO ACCOMMODATE NEW DOOR UNFINISHED STO. , REMOVE EXISTING ,/ ROOFING MATERIAL / AT FLAT ROOF 13RD FLOOR DEMO PLAN GENERAL NOTES 1 REMOVE ALL EXISTING EXTERIOR WOOD SHINGLES, REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF r L REMOVE EXISTINB gUTTERS PREPARE ROOF TO RECEIVE NEW DORMER ABOVE BATH 6 REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF I I i I DEMOLITION LEGEND [ ]EXISTING WALLS TO REMAIN EXISTING WALLS TO BE DEMOLISHED REMOVE EXISTING GUTTERS REMOVE EXISTING ROOFING MATERIAL AT FLAT ROOF --1 01 ROOF DEMO PLAN 01/A202 CONSTRUCTION LEGEND I NEW WALLS I EXISTING WALLS TO REMAIN EXHAUST VENT SMOKE DETECTOR/ CARBON MONOXIDE DETECTOR ' NEW ELECTRICAL 5ERVIC£ PANEL MECHANICAL NEW TRIANGLE TUBE BOILERS NEW INDIRECT HEAT WATER TANK NEW PROPANE TANK TO BE INSTALLED IN YARD, LOCATION TO BE DETERMINED. MECHANICAL NEW AIR HANDLER CRAWL SPACE m -- L L 01/A20,~ b 1 PROPOSED BASEMENT PLAN NOTES: 1 ALL EXTERIOR WALLS TO RECEIVE NEW WOOD SHINGLES. 2 ALL EXIST[NO WALLS AND CEILINGS TO BE PATCHED, SKLMMED AND CLEANED, AS REQUIRED. 5, ALL SURFACES TO BE REPAIRED AND REFINISHED, AS REQUIRED NEW COPPER DOWNSPOUT 01/A202 CONSTRUCTION LEGEND NEW WALLS EXIS~NG WALLS TO REMAIN EXHAUST VENT SMOKE DETECTOR/ CARBON MONOXIDE DETECTOR NEW HOSE NEW REPLACED TOILET NEW REPLACED LAVATORY NEW OUTDOOR SHOWER, SLOPED CONCRETE SLAB WiTH DRAIN, LEADING TO DRYWELL, LOCATION OF DRYWELL TO BE DETERMINED o NEW 6x6 POSTS, DETAILING AND FINISH TO MATCH EXISTING INSTALL NEW WINDOW, FILL IN WALL BELOW SILL INSTALL NEW RAILING, MATCH EXISTING OUTglDE SHOWER I I PORCH POWDEF ROOM KITCHEN PORCR LAUNDRY ,' I:II SPRINKLER PATH FROM DOOR E103 TO BATH E ON SECOND I RECESSED SPRINKLERS TO NEW YORK RESIDENTIAL NEW DISHWASHER NEW MICROWAVE NEW RELOCATED SINK NEW AND CABINETS NEW REPLACED RANGE NEW WASHER AND DRYER -- NEW HOSE BIB --' RELOCATED DOOR INSTALL NEW CABINETRY AS SHOWN INSTALL NEW DUTCH DOOR TO MATCH EXISTING DOOR IN DININB ROOM MW NEW REFRIGERATOR KITCHEN 1' 2' 11" NEW HOSE BIB I I REFURBISH AND REFINISH EXISTING WINDOWS PORCH TV ROOM 1ST FLOOR HALL POWDER ROOM PANTRY REFURBISH AND R(EF[NISH EXISTING /WINDOW INSTALL NEW BALUSTRADE, MATCH EXISTING DINING PORCH Il_ DINING NEW COPPER DOWNSPOUTS REFURBISH AND REFINISH EXIS~NG WINDOW 01/A204 REFURBISHED EXISTINO LAVATORY NEW REPLACED TOILET REFURBISH AND REFINISH EXISTING WINDOW LIMING il SOUTH PORCH f IZ?, I ± SUN ROOM NEW COPPER DOWNSPOUT AT STONE COLUMN NEW STAIR AT SOUTH PORCH. NEW STONEWORK AND TREAD D TO MATCH NEW STAIR AT SUNF NEW COPPER DOWNSPOUT -- AT STONE COLUMN I1%, 17' RECONSTRUCTED SOFFIT AND TRIM DETAILING TO MATCH EXISTING NEW WINDOW & FRENCH DOOR SYSTEM WITH INTEGRATED COLUMNS AT SUN ROOM -- NEW STAIR AT SUN ROOM. NEW STONEWORK AND TREAD DETAILING TO MATCH NEW STAIR AT SOUTH PORCI-L PROPOSED 1ST FLOOR PLAN NOTES: L ALL EXTERIOR WALLS TO RECEIVE NEW WOOD SHINGLES, 2, ALL EXISTING WALLS AND CEILINGS TO BE PATCHED, SKIMMED AND CLEANED, AS REQUIRED, ALL SURFACES TO BE REPAIRED AND REFINISHED, AS REQUIRED, NEW REPLACED LAVATORY NEW REPLACED TOILET EXISTING TUB NEW COPPER TILES AT ALL FLAT ROOFS NEW RELOCATED TOILET NEW RELOCAll'D LAVATORY NEW SHOWER RELOCATED DOOR FROM EXIS~N8 BEDROOM 3 CLOSET NEW REPLACED TOILET RELOCATED EXISTIND TUB NEW COPPER TILES AT ALL FLAT ROOFS NEW SHOWER NEW FRAMELESS GLASS SHOWER ENCLOSURE -- EXISTING SINK TO BE REFURBISHED EXISTING TUB BATH 4 BATH 3 BA~H 2 1% CLO, CLO. (~) SPRINKLER PATH FROM OATH 6 TO DOOR E103 ON FIRST FLOOR, RECESSED SPRINKLERS TO DOMP,L.¥fiWI-~ NEW YORK RESIDENTIAL COD~AJ6? BEDROOM 5 REFURBISH AND REFINISH EXISTING WINDOW BEDROOM 01/A202 BEDROOM 2 2ND FLOOR BALL CLO. CLO t' Z BEDROOM 3 EFURBISH AND REFINISR EXISTINO WINDOW I I I BALCONY REFURBISH AND REFINISH EXISTING WINDOWS INSTALL RELOCATED DOORS FROM BEDROOMS 4 AND 5 SITT~NO ROOM CONSTRUCTION LEGEND NEW WALLS EXISTING WALLS TO REMAIN EXHAUST VENT SMOKE DETECTOR/ CARBON MONOXIDE DETECTOR RELOCAIED DOOR FROM EXTG. MASTER BATH ® ALIGN MASTER BATH r RELOCATED BOOR FROM EXTG, MASTER BEDROOM ENTRY Z MASTER BEDROOM RELOCATED ' DOOR FROM ~' E]TG. BATH 4 CLO, NEW COPPER TILES AT ALL FLAT ROOFS J L 01/A204 01 PROPOSED 2ND FLOOR PLAN PERMIT SET 03.06,09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITEGq'S, PLLC PROPOSED SECOND FLOOR PLAN A102 PROJECT: t27 NOTES: 1. ALL EXTERIOR WALLS TO RECELVE NEW WOOD SHINGLES. 2. ALL EXISTING WALLS AND CEILINGS TO BE PATCHED, SKIMMED AND CLEANED, AS REQUIRED. 3 ALL SURFACES TO BE REPAIRED AND REFINISHED, AS REQUIRED. NEW COPPER TILES AT ALL FLAT ROOFS NEW COPPER TILES AT ALL FLAT ROOFS SPRINKLER PATH FROM BATH 6 TO BOOR E105 ON FIRST FLOOR. RECESSED SPRINKLERS TO COMPLY WI~ NEW YORK RESIDENTIAL CODE AJ60& UNFINISHED STO, NEW ECRESS WINDOWS, FiLL IN WALL BELOW SiLL BEDROOM 8 01/A202 CLO. 3RD. FLOOR HALLWAY ~BATN 5 ~ BATH 6 UNFINISHED STO. RELOCATED DOOR / NEW RELOCATED TUB " NEW RELOCATED LAVATORY NEW RELOCATED TOILET -- RELOCATED CABINETRY NEW CABINETRY CONSTRUCTION LEGEND NEW WALLS EXISTING WALLS TO REMAIN EXHAUST VENT SMOKE DETECTOR/ CARBON MONOXIDE DETECTOR NEW COPPER ~LES AT ALL FLAT ROOFS .-_. ? -- RELOCATED DOOR __ 5'-7~" F2'-0¢3'' NEW DOORS UNFINISHED STO II BEDROOM 8 ' NEW TOILET NEW DORMER NEW LAVATORY NEW SHOWER UNFINISHED STO, · LJ C U L ,1_ 01/A204 1 PROPOSED 3RD FLOOR PLAN NOTES: 1. ALL ROOFS TO RECEIVE NEW WOOD SHINGLES. SHINGLES WILL BE RED CEDAR PERFECTION //1,. 2. NEW COPPER HALF ROUND GUTTEBS WITH NEW COPPEB DOWNSPOUTS WILL BE INSTALLED WNERE SHOWN. 5. CHIMNEY FLASHING TO BE REPAIRED/REPLACED AS NECESSARY. NEW COPPER GMTTER 01/A202 NEW WALLS EXISTING WALLS TO REMAIN EXHAUST VENT SMOKE BETECTOR/ CARBON MONOXIDE DETECTOR NEW COPPER GUTTER NEW BALUSTRADE TO MATCH EXISTING NEW COPPER TILES AT ALL FLAT ROOFS NEW COPPER OUTTER NEW BALUSTRADE TO MATCH EXISTING NEW COPPER fiLES AT ALL FLAT ROOFS PERMIT SET 03,06.09 REVISI[3N ISSUE DATE HIGHLAND HOUSE NEW COPPER TILES AT ALL FLAT ROOFS NEW DORMER ABOVE BATH 6 TO MATCH EXISTING IN BATH 5 NEW BALLUSTRADE TO MATCH EXIS~NG -- '- NEW COPPER GUTTER I I I NEW COPPER GUTTER NEW COPPER TrLES AT ALL FLAT RDOFS NEW BALUSTRADE TO MATCH EXISTINO NEW COPPER OUTER KINLIN RUTHERFURD ARCHITECTS, PLLC 01/A20¢- 1 PROPOSED ROOF PLAN IX4'=1'-O' PROPOSED ROOF PLAN A104 PROJECT: 12'7 1, NEW SHINGLES WILL BE RED CEDAR PERFECTrON #1 ON ALL EXTERIOR WALLS AND ROOFS, 2, NEW COPPER HALF-ROUND GUTTERS, WHERE SHOWN, WITH NEW COPPER DOWNSPOUTS, 3, ALL EXTERIOR WOODWORK TO BE REFINISHED AND REPAINTED. 4. CHIMNEY FLASNING REPAIRED/REPLACED AS NECESSARY. NEW ORIEL BAY WITH EGRESS WINDOWS, BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE, DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBLE CASEMENT WINDOW #232 ON WEST FACADE. ~, T.O FINISH FLOOR %0 FINISH FLOOR ELEV. 10'7" NEW SECOND FLOOR BALLUSTRADE TYP, TO MATCH EXISTINO AT FIRST FLOOR PERMrT SEt 03~06.09 HIGHLAND HOUSE T.O FINISH FLOOR ELEV 0'0" NEW 2" BLACK METAL HANDRAIL AT ALL EXTERIOR STAIRS TYP. REPAIR AND ALTER STRUCTURAL FRAM[NO AND FINISH WOODWORK AT KITCHEN PORCH. NEW LATTICE PANELS TO MATCH EXISTING, NEW LATTICE DOORS (NEW OUTDOOR SHOWER BEHIND) -- NEW STAIR AT SUN ROOM NEW STONEWORK AND TREAD DETAILING TO MATCH NEW STArR AT SOUTH PORCH. 1 NORTH ELEVATION I/¢==1'-0" KINLIN RUTHERFURD ARCHITECTS, PLLC NORTH ELEVATION PROJECT: 127 A201 1. NEW SHINGLES WILL BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS. 2. NEW COPPER HALF ROUND GUTTERS, WHERE SHOWN, WITH NEW COPPER DOWNSPOUTS, ,3 ALL EXTERIOR WOODWORK TO BE REFINISHED AND REPAINTED, 4. CHIMNEY FLASHING REPAIRED/REPLACED AS NECESSARY, ,.,, %0 RIDGE ~" ELEV, 29'2" NEW ORIEL BAY WITH EGRESS WINDOWS, BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBGE CASEMENT W~NDOW ¢252 ON WEST FACADE *-, TO FINISH FLOOR " ELEV. 19'10" NEW SECOND FLOOR BALLUSTRADE TYP, ~ TO MATCH EXISTING AT FIRST FLOOR ", ~-. T.O FINISH FLOOR " ELEV. 10'7' ,~, %0 FINISH FLOOR -, ~' ELEV. 0'0" )1 = NEW 2" BLACK METAL HANDRAIL AT ALL EXTERIOR STAIRS TYP, :,1 -- NEW SECOND FLOOR BALLUSTRADE TYP. TO MATCH EX¢SqNG AT FIRST FLOOR F REPAIR AND ALTER STRUCTURAL FRAMING AND FINISH WOODWORK AT KITCHEN PORCH. NEW LATTICE PANELS TO MATCH EXISTIND. PERMIT SET 03,06,09 REVISION ISSUE DA~ HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC 01 EAST ELEVATION EAST ELEVATION PROJECT: 127 A202 1, NEW SHINGLES WILL BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS, 2, NEW COPPER HALF-ROUND GUTTERS, WHERE SHOWN, WITH NEW COPPER DOWNSPOUTS. 5. ALL EXTERIOR WOODWORK TO BE REFINISHED AND REPAINTED. 4, CHIMNEY FLASHING REPAIRED/REPLACED AS NECESSARY. ,.*, T.O RIDGE '"' ELEV. 29'2" ~ TO FINISH FLOOR ELEV. 19'10" NEW SECOND FLOOR BALLUSTRADE TYP. TO MATCH EXISTING AT FIRST FLOOR TO FINISH FLOOR ELEV 10'7" CORNICE AND DENTILS TO BE -- REPLACED/REPAIRED AS NEEDED NEW BEAM, HEADERS, AND CASINGS NEW WOOD COLUMNS AT SUN ROOM NEW STAIR AT SUN ROOM. NEW STONEWORK AND TREAD DETAILING TO MATCH NEW STAIR AT SOUTH PORCH FINISH FLOOR ELEV. 0'0" NEW DORMER TO MATCH EXISTING, TRIM DETAILING AND FINISH TO MATCH EXISTING AT LIVING ROOM NEW DOUBLE-HUNG WINDOWS IN EXISTING OPENLNG 01 SOUTH ELEVATION PERMIT SET 03.06.09 REVISION ISSUE DATE HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC SOUTH ELEVATION PROJECT:127 A203 1. NEW SHINOLES WILL BE RED CEDAR PERFECTION #1 ON ALL EXTERIOR WALLS AND ROOFS. 2. NEW COPPER HALF-ROUND GUTTERS, WHERE SHOWN, WITH NEW COPPER DOWNSPOUTS. 5, ALL EXTERIOR WOODWORK TO BE REFINISHED AND REPAINTED, 4, CHIMNEY FLASHINO REPAiRED/REPLACED AS NECESSARY, NEW DORMER TO MATCH EXISTING, TRIM DETAILING AND FINISH TO MATCH EXISTING T 0 RIDGE ELEV. 29'2" NEW ORIEL BAY WITH EGRESS WINDOWS. BRACKET AND TRIM DETAILING TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. RIDGE PROFILE TO MATCH EXISTING ORIEL WINDOW ON EAST FACADE. DIAMOND MUNTIN PATTERN ON NEW EGRESS CASEMENT WINDOWS TO MATCH DOUBLE CASEMENT WINDOW #252 ON WEST FACADE. ® T,O FINISH FI OOR ELEV. 19'10" NEW SECOND FLOOR BALLUSTRADE TYP TO MATCH EXISTING AT FIRST FLOOR FINISH FI OOR ELEV, 10'7" ~ T.O FINISH FLOOR REPAIR AND ALTER STRUCTURAL FRAMINO AND FINISH WOODWORK AT KITCHEN PORCH. NEW LATTICE PANELS TO MATCH EXISTING, NEW RAILS TO MATCH EXISTING. NEW INSWING DUTCH DOOR TO MATCH EXISTING DUTCH DOOR AT DINING ROOM NEW CUSTOM INSWlNG FRENCH DOORS WITH SCREENS NEW WOOD COLUMNS TO MATCH EXISTING, WITH NEW STONE BASES TO MATCH EXISTING NEW STAIRS AT SUN ROOM AREA OF NEW STONEWORK FOR NEW FRENCH DOORS AND STAIRS NEW SECOND FLOOR BALLUSTRADE TYP TO MATCH EXISTING AT FIRST FLOOR 'N CORNICE AND DENTILS TO BE REPLACED/REPAIRED AS NEEDED NEW BEAM, HEADERS, AND CASINGS NEW CUSTOM BUILT CASEMENT BAY WINDOWS AT SUN ROOM, NEW WOOD COLUMNS TO MATCH EXISTIr~ MODIFY EXISTINO STONE BASE TO ACCOMODATE NEW COLUMN LOCATIONS 0 1 WEST ELEVATION PERMIT SET 03,06,09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC WEST ELEVATION PROJECT: 127 A204 W l N DOW SC H E D U LE <... RO. . O.EN.NO D,.ENS,ONS ,..ST "E VEH,.EO,N T.E.E.D Basement Rough Opening Size Jamb Divided Window# Rm Name Type Manufact, Product # Description Width Height Depth light Screen Hardware Exterior Notes 001 Basement A Marvrn CUSTOM WINDH Wood Insert Double Hung S'*S" 3'-2 1/2" V.I.F. SDL Y White Wood Replacement wrndow. Verify all dimensions in field. 002 Basement A Marvin CUSTOM WIN DH Wood Insert Double Hung 3'-0" 3'-2 3/4" V.I.F. SDL Y White Wood Replacement window. Verify all dimensrons in field. 003 Basement G Marvin CUSTOM WURAWN Wood Replacement Awning 3L4 1/2" 1'-10 1/2" V.I.F. SDL Y White Wood Replacement window, Verrfy all d~mensrons In field. 004 Basement G Marvin CUSTOM WURAWN Wood Replacement Awning 3'-4 1/2" 1L101/2" V.I.F. SDL Y Whrte Wood Replacement window, verrfy all dimensions in f[eJd. Wood First Floor Rough Opening Size Jamb Divided Window# Rm Name Type Manufact. Product # Description Width Height Depth light Screen Hardware Exterior Notes 101 Kitchen C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-0" 3'- 8 1/2" V.I,F, SDL Y White Wood Replacement window, Verify all dimensions in field. 102 Porch Powder Room C Marvin CUSTOM WlNDH Weed Insert Double Hung 2'-0" 3'-8 1/2" V,I,F, SBL Y White Wood Replacement window. Verlflj all dimensrons In field, 103 Kltshen E Marvin CUSTOM W[NDH Wood Insert Double Hung 1'-8" 3'-8 1/2" V,I.F. SDL Y White Wood Replacement window, Verify all dimensions In field. 104 Kitchen B Marvin CUSTOM WINDH Wood Insert Double Hung 4'-0" 2'-8 1/2" V.I.F. SDL Y White Wood Replacement window. Verify all dlmensrons in field. 105 TV Room C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-8 1/4" 5'~, 1/2" V,I,F. SDL Y White Wood Replacement window, Verify all dimensions In field. 106 TV Room C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-8 1/4" 5'-4 1/2" V.I.F. SDL Y White Wood Replacement window. Verify all dimensions in field. 107 Living Room C Marvin CUSTOM WINDH Wood insert Double Hung 2'-113/4" 5'-3 1/4" Vd.F. SBL Y White Woad Replacement window, Verify all dimensions in field, 108 Living Room C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-11 3/4" 5'-3 1/4" V.I.F. SDL Y White Wood Replacement window. Verify all dimensions In field. 109 Living Room C Marvin CUSTOM WINDB Wood Insert Double Hung 2'-11 8/4" 5'-3 1/4" V.I.F. SDL Y White Wood Replacement window. Verrfy all dimensions rn field. 110 Living Room C Marvin CUSTOM WlNDH Wood Insert Double Hung 2'-12 3/4" 5'-3 1/4" V.[.F. SBL Y White Wood Reielacement window, Verify all dimensions rn ftsld. 137 Laundry C Marvin CUSTOM WINDH Wood Insert Double Hung 2'*0" 3'- B 1/2" V,I,F, SDL Y White Wood Replacement window, Verify all dimensions in f[eJd. 111 Sun Room P Custom Architectural Components Frxed Casement 2'-1" 6'-4" V.I.F. SDL Y White Wood New window at Sun Porch. 112 Sun Room J Custom Architectural Components Fixed Transom 4'-11 1'-7 1/2" V.I,F. SDL Y White Wood New window at Sun Porch. 113 Sun Room P Custom Architectural Components Fixed Casement 2'-1" 6'-4" V,I,F, SDL Y White Wood New window at Sun Porch. 114 Sun Room N Custom Architectural Components Fixed Casement 1'-3" 5'-11" V,I,F. SDL Y White Wood New window at Sun Porch. 115 Sun Room L Custom Architectural Components Operating French Casement 4L2'' 5'-11" VJ.F, SDL Y White Wood New window at Sun Porch. 116 Sun Room N Custom Architectural Components Fixed Casement 1L3" 5'-11" VJ,F. SDL Y White Wood New window at Sun Porch, 117 Sun Room N Custom Architectural Components Fixed Casement 1'-3" 5'-11" V.LF. SDL Y White Wood New window at Sun Porch, 118 Sun Room L Custom Architectural Components Operating French Casement 4'-2" 5'-11" V.I.F, SDL Y White Wood New window at Sun Porch, 119 Sun Room N Custom Arehftetsural Components Fixed Casement 1'-3" 5'-11" V.I,F, SDL Y White Wood New wrndow at Sun Porch. 120 Sun Room N Custom Architectural Components Fixed Casement 1'-9" 5'-11" V.I,F. SDL Y White Wood New wTndow at Sun Porch. 121 Sun Room L Custom Architectural Components Operating French Casement 4'-2" 5'-11" V,LF. SOL Y White Wood New window at Sun Porch, 122 Sun Room N Custom Architectural Components Fixed Casement t'-3" 5'-11" V,I,F, SDL Y White Wood New window at Sun Porch. 2.23 Sun Room N Custom Archltecturar Components Fixed Casement 1'-3" 5'-11" V.I.F. SDL V White Wood New wTndow at Sun Porch, 124 Sun Room M Custom Architectural Components Fixed Casement 2'-1" 5'-11" V,I,F. SDL Y White Wood New window at Sun Porch, 125 Sun Room J Custom Architectural Components Fixed Transom 4'-tt I'-0 1/2" V.I.F. SDL Y White Wood New window at Sun Porch, 126 Sun Room M Custom Architectural Components Fixed Casement 2'-1" 5'-11" V.I,F. SDL Y White Wood New window at Sun Porch, 127 Sun Room N Custom Archrtectural Components Fixed Casement 1'-3" 5'-11" V,I,F. SDL Y White Wood New wrndow at Sun Porch, 128 Sun Room M Custom Architectural Components Fixed Casement 2'-2" 5'-11" V,I,F, SDL Y White Wood New wrndow at Sun Porch, 129 Sun Room K Custom Architectural Components Fixed Transom 2'-8" 1'-0 1/2" V,I,F. SDL Y White Wood New window at Sun Porch, 130 Sun Room M Custom Architectural Components Fixed Casement 2'-1" 5~-11'' V,I,F, SDL Y White Wood New window at Sun Porch. 131 Sun Room M Custom Architectural Components Fixed Casement 2'-1" 5'-11" V. hF, SDL y White Woad New window at Sun Porch, Second Floor Rough Opening Size Jamb Divided Window# Rm Name Type Manufact. Product # Description Width Height Depth light Screen Hardware Exterior Notes 201 Bedroom 5 C Marvin CUSTOM WINDH Wood Insert Double Hqng 2'-8" 4'-10 1/2" V.I,F, SDL Y White Wood Replacement window. Verify all dimensions fn field, 202 Bedroom 5 C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-8" 4'*±0 1/2" V,I.F. SDL y White Wood Replacement window, Verify all dimensions rn field, 203 Bath 4 C Marvin CUSTOM WINBH Wood Insert Double Hung 2'-8" 4'-10 1/2" V,I,F. SDL Y White Wood Replacement window, Verify all dimensions in field. 204 Bath 4 C Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-B" 4'-10 1/2" V.I,F. SBL y White Wood Replacement window, Verify all dimensions in field. 205 Bath 3 C Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-0" 4'-10 1/2" V.hF, SDL Y White Wood Replacement window. Verify all dimensions In field. 206 Bath 2 C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-0" 3'-8 1/2" V, LF. SDL y White Wood Replacement window. Verify all dimensions in field. 207 Bedroom 2 C Marvin CUSTOM WlNDH Wood Insert Double Hung 2'-0" 4'-10 1/2" VJ.F. SDL y White Wood Replacement window, Verify al/dimensions In field, 208 Bedroom 2 C Marvin CUSTOM WlNDN Wood Insert Double Hung 2'*8" 4'-10 1/2" V,LF. BDL Y White Wood Replacement window. Verify all dimensrons In frald. 209 Bedroom 2 C Marvin CUSTOM WlNDH Wood Insert Double Hung 2'-0" 4'-10 1/2" Vd.F, SDL Y White Wood Replacement window, Verify all dlmensrons in field, 210 Sitting Room C Marvrn CUSTOM WlNDH Wood Inaert Double Hung 3'-0" 4'-10 1/2" V,I,F. SDL Y White Wood Replacement window, Verify all dimensions in field. 211 Sitting Room C Marvrn CUSTOM WlNDH Wood Insert Double Hung 2'-0" 4L10 1/2" V.LF. SDL Y White Wood Replacement window, Verify all dimensions In field, 212 BIthng Room c Marvrn CUSTOM W[NDH Wood Insert Double Hung 2'-0" 4'-10 1/2" V.I,F, SDL Y White Wood Replacement window. Verrfy all dimensions rn field, 213 Master Bedroom C Marvin CUSTOM WlNDH Wood Insert Double Hung 2'-0" 5'-0 1/2" V,LF. SDL Y White Wood Replacement window. Verify all dimensions rn field, 214 Master Bedroom C Marvrn CUSTOM WlNDH Wood Insert Double Hung 2'-0" 5'-0 1/2" V,I,F, SDL Y Whrte Wood Replacement wrndow. Verify ail dimensions In field. 215 Master Bedroom C Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-8" 5'-0 1/2" V,LF. SDL Y White Wood Replacement window, Verrfy all dimensions In field. 216 Master Bedroom C Marvin CUSTOM WINBH Wood Insert Double Hung 2'-8" 5'-0 1/2" V.I.F, SDL Y White Wood Replacement wrndow, Verify all dimensions in field. 217 Master Bedroom C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-8" 5'-0 1/2" V,I,F, SDL Y White Wood Replacement window, Verrfy all dimensions rn field. 218 Master Bath D Marvin CUSTOM WINDH Wood Insert Double Hung 1'-8" 3'-i" Vd,F, SDL Y White Wood Replacement window, Verrfy all drmensions in field, 219 Bedroom 3 C Marvin CUSTOM WINBH Wood Insert Double Hung 2'-0" 3'-6 1/2" V,LF. SDL Y White Wood Replacement window, Verify all drmenslons in field, 220 Bedroom 3 C Marvin CUSTOM WINDH Wood Insert Double Hung 2'*0" 3'-6 1/2" V.I.F. SDL Y White Wood Reb]acement window. Verify all dimensions In field, 221 Bedroom 4 C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-0" 4'-10 1/2" Vd,F, SDL Y White Wood Replacement window, Verify all dimensions in field. 222 Bedroom 4 C Marvin CUSTOM WINDH Wood Insert Double Hung 1'-9" 4'-10 1/2" V.I.F. SDL Y White Woad Replacement wrndaw. Verrfy all drmensians in field, 223 Bedroom 4 C Marvin CUSTOM WINDH Wood Insert Double Hung 2'-0" 4'-10 1/9" V.I.F, SDL Y White Woad Replacement window. Verify all drmenslons in field. 224 Bedroom 5 C Marvrn CUSTOM WINDH Wood Insert Bauble Hung 2'-0" 4'-10 1/2" V.I.F. SDL Y White Wood Replacement wrndow. Verrfy ail dimensions rn field, Third Floor Rough Opening Size Jamb Divided Window# Rm Name Type Manufact, Product # Description Width Height Depth light Screen Hardware Exterior Notes 301 Bedroom 6 Q Marvin WCM2848 Wood Casement 2'-5" 4'-0 9/16" V.LF, SDL Y White Wood New Egress Window, Verify all dimensions in field, 302 Bedroom 6 Q Marvin WCM2848 Wood Casement 2'-5" 4'-0 9/16" VJ,F. SDL Y White Wood New Egress Window, Verify all dimensions rn field. 303 Third Floor Stair H Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-10" 2'-10 1/2" V,LF, SDL Y White Wood Replacement window. Verify all dimensions in Reid. S04 Bedroom 7 C Marvin CUSTOM WlNDH Wood Insert Double Hung 2'-0 1/2" 3'-4 1/2" V.I.F. SDL Y White Wood Replacement window. Verify all dlmensrons in Reid. 305 Bedroom 7 C Marvin CUSTOM WINDN Wood Insert Double Hung 2'-0 1/2" 2'-4 1/2" V,I.F. SBL Y White Wood Replacement window, Verify all dimensions In field, 306 Bedroom 8 C Marvin CUSTOM WINDH Wood Insert Double Hung 3'-0" 3'-51/2" V,I,F, SDL Y White Wood Replacement window, Verify ail dimensions in field. 307 Bath 6 C Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-11 1/4" 1'-7 1/2" V.I,F. SDL Y White Wood Replacement window, Verlf7 all dimensions in field. 308 Bath 6 F Marvrn CUSTOM WINDH Wood Insert Double Hung 2'-11 1/4" 1'-7 1/2" V.I.F, SDL Y White Wood Replacement window. Verify all drmensions in field. NOTES: 1, WINDOW TRiM TO BE INSTALLED BY MANUFACTURER UNLESS OTHERWISE NOTED, 2, VERIFY ROUGH OPENINGS AT REPLACEMENT UNITS WITH IN-FIELD MEASUREMENTS, CONSULT WITH ARCHITECT IN CASE OF DISCREPANCY. 3, VERIFY ROUGH OPENINGS AT NEW UNITS WITH DIMENSIONS ON CONSTRUCTION PLAN AND DETAIL SHEETS. 4. PATCH INTERIOR AND EXTERIOR WALLS AS REQUIRED TO RECEIVE NEW TRIM, 5. ALL NEWAND REPLACEMENT EXTERIOR WINDOWS TO BE HURRICANE RATED MARVIN - STORMPLUS IMPACT ZONE 3). WINDOW TYPES '1 1 WINDOW SCHEDULE AND TYPES PERMITSET 03,06.09 HIGHLAND HOUSE KINLIN RUTHERFURD ARCHITECTS, PLLC WINDOW SCHEDULE PROJECT: 127 A501 EXTERIOR DOOR SCHEDULE First Floor Rough Opening Size Door # Rm Name Type Description Width Height E103 Sun Room B New door to match exrstrng (2) Clad Insw[ng French Door 4'-0 1/2'~ 6'-10" E104 Sun Room C New door to match existing Crad Inswing French Door 2'-8 ?2" El05 Sun Room D New door (2) C~ad Inswing French Door 6'-1 g/4" B'-2 1/2" E109 Kitchen A New door to match existing Dutch door at Dining Room Wood Inswlng Dutch Door 3'-1" 7'-6 1/2 NOTES( 1. DOOR TRiM TO BE INSTALLED BY CONTRACTOR UNLESS OTHERWISE NOTED, 2. VERIFY ROUGH OPENINGS AT REPLACEMENT DOORS WITH IN-FiELD MEASUREMENTS. CONSULT WrTH ARCHITECT IN CASE OF DISCREPANCY. 3. VERIFY ROUGH OPENINGS AT NEW UNITS WiTH DIMENSIONS ON CONSTRUCTION PLAN AND DETAIL SHEETS, 4, PATCH INTERIOR AND EXTERIOR WALLS AS REQUIRED TO RECEIVE NEW TRIM. 5. ALL NEW AND REPLACEMENT EXTERIOR DOORS TO BE HURRICANE RATED (MARVIN -STORMPLUS iMPACT ZONE B). 6, ALL EXTERIOR COORS TO BE REFINISHED AND REFURBISHED AS REQUIRED, INTERIOR DOOR SCHEDULE First Floor Rough Opening Size Door # Rm Name Type Comment Description Width Height 101 Laundry D Relocate existing door at Mudroom entry Solid Core 2'*9" 7'-6 1/2" Second Floor Rough Opening Size Door # Rm Name Type Comment Description Width Height 201 Master Bedroom D Relocate existing door at Master Bedroom entry Solid Core 2'-9" 7'-1 1/2" 202 Master Bath D Relocate existing door at Beth 4 entry Solid Core 2L9'' 7'-1 1/2" 203 Bedroom 3 D Relocate existing door at Bedroom 2 entry Solid Core 2L9" ?'-1 1/2" 204 Bedroom 3 D Relocate existing door at Master Bathroom entry Solid Core 2'-2" 7'-1 1/2" 205 Bedroom 3 D Relocate existing door at Bedroom 4 c~oset Solid Oore 2'-7" 7'-1 1/2" 206 Bedroom 4 B Relocate exlsUng door at Bedroom 3 0loser Solid Core 2'-7" 7'-1 1/2" 207 Bedroom 4 D Relocate existing door at Bedroom 5 entry solrd Core 2'-9" ?'-1 1/2" 208 Bedroom 5 D Relocate existrng door at Bedroom 4 entry Solid Core 2'-9" 7'-1 1/2" 209 Bath 4 D Relocate existing door at Bedroom 3 closet Solid Core 2'-7" 7'-1 1/2" 210 Bedroom 2 D Rerocate existing door at Bedroom 3 entry Solid Core 2'-9" 7'-1 1/2" 211 Sitting Room D Relocate exrstrng door at Bedroom 4 passage I (2) Solid Core French Doors 5'-5" 7'-1 1/2" Sitting Room D Relocate existing door at Bedroom 5 closet I Third Floor Rough Opening Size Door # Rm Name Type Description Width Height 301 Bedroom 7 E New door to match exlatlng doors Solid Core 2'-7" 302 Bedroom 8 E Relocate existing door at Bedroom 8 entry Sol~d Core 2'-7" 6'-8" 303 Bath 6 E Relocate ex~stlng door at Bath 5 entry Solid Core 2'-7" 6'-8" 304 Bath 5 E Relocate existing door at Storage (Bath 6) Entry Solid Core 2'-6 1/2'r 6'-8" 305 Bedroom 6 F New door to match existing doom Solid Core 2'-7" 4'-2" 306 Bedroom 8 E New closet door to match existing doors Solid Core 2'-7' 6'-B" NOTES~ 1, DOOR TRrM TO BE rNSTALLED BY CONTRACTOR UNLESS OTHERWISE NOTED, 2, VERIFY OPENINGS AT INTERrOR DOORS WiTH IN*FIELD MEASUREMENTS, CONSULT WiTH ARCHITECT IN CASE OF DISCREPANCY, 3. REFINISH AND REFURBISH AS NECESSARY INTERIOR DOORS TO BE RE-USED, 4. CONSULT CONSTRUCTION PLAN FOR NEW INTERIOR DOOR LOCATIONS FOR RE-USED INTERIOR DOORS. 5. PATCH ALL INTERIOR WALLS AND TRIM TO MATCH EXISTING AS REQUIRED. 6. ALL [NTBRIOR DOORS TO BE REFrNISHED AND REFURBISHED AS REQUIRED. PERMIT SET 03.06.09 HIGHLAND HOUSE ,/ DOOR TYPES 01mDOOR SCHEDULE AND TYPES KINLIN RUTHERFURD ARCHITECTS, PLLC DOOR SCHEDULE PROJECT: 127 A502 Ol/A20¢ 01/A202 .--2X10 RIDGE REAM --2X8 ROOF RAFTERS 0 1 STRUCTURAL DIAGRAM PERI~IT SET 03.06.09 HIGHLAND HOUSE FISHERS ISLAND, NEW YORK KINLIN RUTHERFURD ARCHITECTS, PLLC STRUCTURAL DIAGRAM PROJECT: 127 S101 PLUMBING NOTES 1, DO NOT SCALE FROM RISERDIAGRAMS. 2, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE BUILDING CODE OF THE TOWN OF SOUTHOLD AND RS-16. 3. OBTAIN AND PAY FOR ALL PERMITS, CERTIFICATES, ETC, REQUIRED, 4, VERIFY FIELD CONDITIONS AND LOCAL CODES BEFORE SUBMITTING BID, 5, DELIVER CERTIFICATES OF FINAL INSPECTION TO OWNER BEFORE APPLYING FOR FINAL PAYMENT. 6, PITCH HORIZONTAL DRAINAGE PIPING 3" DIAMETER AND LESS 1/4" PER FOOT MINIMUM; OVER 3" DIA. PITCH 1/8" PER FOOT MINIMUM, 7. SPACING BETWEEN CLEAN-OUTS SHALL NOT EXCEED 50'-0". 8, GUARANTEE ALL WORK FOR A PERIOD OF 1 (ONE) YEAR FROM DATE OF FINAL ACCEPTANCE, 9, ALL HOT AND COLE WATER LINES TO HAVE SHUTOFF VALVES. 10, ALL HARD PIPED FIXTURES AND APPLIANCES WILL HAVE BACK FLOW PREVENTION DEVICES RELOCATED LAVATORY - RELOCATED TOILET NEW LAVATORY NEW SHOWER NEW TOILET THIRD FLOOR BATH 5 BATH 6 THIRD FLOOR SECOND FLOOR BATH 4 NEW SHOWER RELOCATED LAVATORY - RELOCATED TOILET EXISTING LAVATORY EXrSTING TUB - REPLACED TOILET -- NEW SHOWER REPLACED LAVATORY EXISTING TUB REPLACED TOILET BATH 3 BATHI2 RELOCATED LAVATORY --NEW LAVATORY TUB - REPLACED TOILET MASTERBATH SECONDFLOOR PERMITSET 03.06.09 HIGHLAND HOUSE SHOWER FIRST FLOOR OUTDOORSHOWER '%"~CLEANOUT REPLACED LAVATORY FOILET NEW WAS~HING MACHINE 12" / PORCH ~I/ POWDERROOM ~ILAUNDRY PANTRY SiNK KVENT SHWASHER RELOCATED 8INK KITCHEN 2" 2" TING LAVATORY LIVING POWDER ROOM NEW DRYERAT NEW LOCATiON '~ LAUNDRY ROOM / ¥ NEW RANGE AT EXISTING LOCATION KITCHEN FIRST FLOOR EXrSTINO GAS LINE KINLIN RUTHERFURD ARCHITECTS, PLLC 02,.,.,.PLUMB[NG RISER DIAGRAM 01 GAS RISER DIAGRAM RISER DIAGRAMS PROJECT:127 P101