Loading...
HomeMy WebLinkAbout36647-ZTown of Southold Annex 54375 Main Road Southold, New York 11971 12/27/2011 CERTIFICATE OF OCCUPANCY No: 35359 Date: 12/27/2011 THIS CERTIHES that the building Location of Property: SCTM #: 473889 Subdivision: DECK 425 Bay Ave, East Marion, Sec/Block/Lot: 31.-10-12 Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this ofliced dated 8/10/2011 pursuant to which Building Permit No. 36647 dated 8/22/2011 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: deck addition to an existing one family dwellin~ as applied for. The certificate is issued to Huntington, Amy & Salerno, Douglas (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED ~t~zedAignatu/e TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 36647 Permission is hereby granted to: Huntington, Amy & Salerno, Dou~llas 167 E 67th St New York, NY 10065 mo~ deck addition to an existing one family dwelling as applied for. Date: 8/2212011 At premises located at: 425 Bay Ave~ East Marion SCTM # 473889 Sec/Block/Lot # 31..10-12 Pursuant to application dated To expire on 2/20/2013. Fees: 8/10/2011 and approved bythe Building Inspector. SINGLE FAMILY DWELLiNG - ADDITION OR ALTERATION CO - ADDITION TO DWELLING Total: $396.00 $50.00 $446.00 Building Inspector Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings, property lines, streels, and unusual natural or topographic features. 2. Final Approval from Health Depk of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming poo] $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Cop)' of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 08/03fz011 New Construction: Location of Property: Old or Pre-existing Building: ~ (check one) 4~5 Bay ave ~ Marion House No. Street Hamlet Owner or Owners of Property: I)oll~rla8 Sa, lei'Ilo Suffolk CounE,' Tax Map No 1000, Section 31 Subdivision Permit No. ~t.~, ~ Health Dept. Approval: Date of Permit. Block 10 Lot Filed Map. Lot: Applicant: Under~xiters Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Final Certificate: (check one) TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: /~_1~$ DATE INSPECTOR~/~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOU~/DATION 1ST [ ] ROUGH PLBG. [ ]/~/OUNDATION 2ND [ ] INSULATION [//]/FRAMING/STRAPPING [ ] FINAL FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [0 ] ~ FRAMING/STRAPPING ['~"FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROU6H) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR~~L,/ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY ROUGH PLBG. [ ] INSULATION [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ~'l~13.D R~PORT DATE ' lo/~ / / ROUGH ~G & PL~G ~S~ON P~N. Y. STA~ E~ CODE ~ / / TOWN OF SOUTHOLD BUILDING DEPARTMENT TILL' N ttA~L L SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTow n. NorthFor k.net BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the tb[Io~ in~ be fcce applying? Board of Health 4 sets of Building plum Planning Board approval Cheek Septic Form. Flood Pemli! Storm-Water Asscssmenl Fonu Contact: Mail to: ))~[[ ~ ~ APPLICATION FOR BUILDING PERMIT ~ST ~ ~mpIc1~ly fillc~ in by w~writ~r or in ink nn~ submi~ to th~ BuiMM~ l~ctor with 4 f lot and of buildings on p~mis~, ~lafionship to adjoining p~is~ or ~bl c s~ or c. ~e wo~ cov~ by th~ application may not be comm~ced ~fore issuance of Building Pe~it. d. Upon approval of this applicati~, ~e Building Ms~ct~ wig isle a Bulldog ~it Io ~e ap~icant. Such a ~it shall ~ kept on the promises available f~ ins~fion th~out the work. e. No building shall ~ ~cupied or ~ed in whole or in ~ for any pu~ose ~hat so ever until [he BMMing Inspector issues a Ce~ificate of ~pancy. f. Eve~ building pe~it shall expi~ if the work authorized has not commenced wi~in 12 monks a~ the ~te of issuance or has not ~ completed wi~in 18 months ~m such date. If no zoning amendments or other ~gal~ons a~ing the p~ have ~ ~act~ in the interim, the Building Ins~ct~ may authorize, in ~iting, t~ extension of the ~it for an addition six momhs. ~e~afler. a new ~it shall be ~quired. APPL1CA~ON 1S HEREBY MADE to the Building ~t for ~e issuance ora Building Pe~it ~nt to the Building Zone ~dinance of the Town of Southold. Suffolk CounW. New York, and ~ber applicable L~s. ~i~n~s or Regulati~s, for the eonst~cdon of building, additions, or aherations or for ~moval or demolition as h~ein d~ The applicant ag~ to comply wi~ all applicable laws, ordinate, building c~e, housing c~e. ~d ~la6ons, and to a~it authofi~d ins~t~ on p~ises and in building f~ neee~ ins~ti~s. State whether applicant is owner, levee, agent, a<hitect, engineer, general eontmctor, el<trlcian, plum~ or builder Oan~ral Contra~or Name of owner of premises Do,n~.lma (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Paul A l~in*lrnaa H - President (Name and title of corporate officer) Builders License No. 4827~ Plumbers License No. Electricians License No. Other Trade's License No. L Location of land on which proposed work will be done: 4~S Bay Ave Eaat ]~on House Number Street County Tax Map No. 1000 Section Subdivision 31 Hamlet Block 10 Lot File~l'~ap No. Lot lg Z $l~te existi~ use and occupancy oflxemiscs mid i~tended use and occupancy ofpmposcd consmlcfion: a. I~isting usc and occupancy ¥i~1 b. lm~dcduseandoconpancy Baek:Dee, k 3. Natm~ ofwodc (cbeck which applicable): New Buildin~ Addition Alteration Repair Removal Demolition Oiler Work Bnild Ilonk Cr)csc6ption) 4. Eslirnat~lCosl $1~,1~ Fee (To be paid on filing this applicalion) 5. If dwelling, nmber of dwelling onits Nmbe~ of dwelling imits on each flonr If garage, number of cam 6. I f business, onmnefcial or mixed ~y, specify natm-e and extent of each lype of use, 7. Dimensions of existing slmchu~."s, if any: Fmnl Rent Delah Height Number of Slo~es Depih Height_ Number of 8. Dimensionsofantirenewconsarucfon: From Rear Dqxh Height Nul~ of Sto~ 9. Size of lot: Front Rear Delah I O. Date of Purchase Name of Former Own~ 11, Zone or use district in ~ich pntmises are situated ~ 12. Do~ ~ conslm~on vinl~l¢ ~y ~oning law, on:linan~ or n~,,id~fion? YES 13. Will Io~ be ~-~graded? YES NO 14. Names of Owner of l~emises Name of Architect Name of Con~ractot NO NO Will excess fill be removed from in,a.~ses? YES Address Phone No. Addn:ss Phone No Address Phone No. 15 a- Is this prope~ within 100 feet of a tidal v~tland or a fi~hwaac~ weOam~. *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is ibis property wilhin 300 feel of a tidal wellan~. * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide sm-roy, to scale. ~ accunte foundation plan and distances to In'ope~y lines, 17. I f elevation at any point on property is at I0 fcct or below, mus~ provide topogr~ical data on survey. I 8. Arc Ole~e any cove~m~ts and resh-iclions with respect to ~is ptopewty? * YES__ NO · IF YES, PROVIDE A COPY. STATE OF NEW YORK) (Name of ind~id~ si~nin8 comracO above nan~L V (C~, A~L ~e ~, ~c.) of~d o~ ~ o~ ~ is ~ a~ m ~ ~ve ~ ~ ~ w~ ~d to ~ ~ fi~ ~ ~i~i~; ~ all ~ ~ ~ ~s ~ ~ ~ to~ ~ offs ~ ~ ~1~ ~ ~t ~ w~ will ~ ~, - ~ .... ~ ~ Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM  PROPERTY LOCATION: S.C.T.M.~ THE FOLLOWING ACTIONS MArY REQUIRE THE SUBM!~_~!ON OF A ~ sO~I O[O 0t..~. STORM'WATEI~GRADING~DRAINAGEANOr-F'_~_~!~n. CONTROL PLAN BlOe~ LO~ .C's="~" Iru:u BY A DESIGN PRC,~-miONAL IN THE STATE OF N .EW YORK. $CO?~ OF WORK - a. ~at Is the Totel Ama of the pmjed pameis? (Inducle Total .'~ea of all Parcels k~catnd MINn t W~ t~s Projest Rat;~Jn Al Stonn-Wa~ Run-Oil the Scop~ of Work ~ P,~o~d Cms~c~e) ~enerated by a Two (2') Ind~ Ra~a ~n Sae? and/or Ground Dts~Jlhence for the proposed Site Improvements and ~le pemlanent u~alfm of condanc~ion ~ . ~./~,,) Impervloes su~aess.) l'ItOVlD~' BIUEI~ FRO'IECI' DESCRmTION -- -- ~e'* "-- 2 D°es the ~ite Plen end/m $un'eY 8hew NI PmPe~:l --'-~ J--"~l Dmlnage Stmctum~ indlus~g ~ & LouslJon? 'lTnis Item~shall inclnde all Prepaid Grade Ct~mges and · Slopes ConVolllng ~aee ~ter Flow. 3 Does the Site Plan and/er Survey descrihe Ihe erosion and sedlmem co~tro~ ixact;ms that wgl he used to conbof site ereslun and alonn water discharges. This -- item must be maintained throughout the Enlire Construction Pe~nd. 4 wi, this P,~j~ Require a~y Land Filling, Gradth~ or ExcavalJon where there is a dllange ta the Natural Existinfl Grade Invok, lng more than 200 Cubic Yards of Material within any Parcel? 5 Will this Applica§~n Rsqulm Land Disturbing AclNttins Encompassing an Area in Excess of Five Th~sand (5,000 S.F.) Square Feet of Ground Surface?~ -- 6 is there a Nalural Water ~-;eume Running through the Site? Is this Project within the Trustees jurisdiction sutxrdted to the Deperlme~t ~ te If~ commencement d com,n~en ac~. inta and/or in the dlrec~on of a Towfl right.of-way? ooN~ t E-'~T~':'I~;C~ ' - COUNTY OF ..~..~:~..~......'~... ............ SS Notary Puldlc, Stnte ~ N~ No. 01BU~'~185.~; That! ................ ~.a.~.~.~.) .................... ~..m; (Iud, sworn, depeses ~ th~cant for Pern~t, An~ that he/she is the .... (cw~, c~. -.~, ~gent. cmx~ ocher, ~.) ....................... Owner and/or represcnt;tdve o£ thc Owner or Owners, and is dttly ;mthorJz~d to pr~onn or ha~: pe~'onncd the s~d work and to make and F]Je this ;Upl)licadon; that aJJ stat~menis cont,~ncd in tJ~ applica~on ~ true to the best of his knowledge and be.l~e£; and that tbe worJ['wiH be perJ'ormcd in thc manner scl: forth in thC appl~(:~l~on t~led herewith. Swon3 to I)el'ore mc ........ ............................................................................................. FORM - 06/t 0 /v';:~2 OF P~OPEg. TY CONTRACTOR NOTES GENERAL NOTES: 1 ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN OF RIVERHEAD, SUFFOLK COUNTY, NEW YORK, BUILDING CODE, FIRE DEPARTMENT RULES AND REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY THE GOVERNINQ BODY OF THE TOWN OF RIVERHEAD, NEW YORK, AGENCIES `3. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS 4. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER 5, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION ARE~, THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS, THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK. 6, THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES; PLUMBING, ELECTRICALS, ETC. · PLUMBING WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS, 8, ELECTRICAL WORK SHALL BE PERFORMED BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH THE BUREAU OF ELECTRICAL CONTROL ALL REQUIRED PERMITS, iNSPECTIONS AND REQUIRED SIGN OFFS, THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPARING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB, 10. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. 1 1 , ALL DIMENSIONS ARE ESTABLISHED FROM THE FINISH LEVEL OF THE FIRST FLOOR, VARIATIONS TO THE HEIOHT OF THE FINISH LEVEL OF THE FIRST FLOOR ARE TO BE REVIEWED FOR APPROVAL BY THE OWNER AND DAK ASSOCIATES, tLC, NO CONSTRUCTION WILL BE ALLOWED TO COMMENCE UNTIL THIS HEIGHT IS APPROVED, 1 2, THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE RESOLUTION, 1.3. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND HE WILL BE RESPONSIBLE FOR ALL DISCONNECTIONS, RECONNECTIONS, AND STARTUPS. 1 4. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH ARCHITECTURAL FEATURES AND STRUCTURE, ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE RESOLUTION RAL NOTES: 1, All studs to be SPF ¢2 or better, ond all other structural wood to be Douglos F~r #2 or better, All structurall wood shell be in accordance with the nationol design specifications for wood constructlon - latest edition. 5 Nailing schedule shall be in accordonce with the specified code, a, All Drusses shall be "shaped" as shown on orchitectural cross sections, Plywood she,athin9, o. All plywood shall be in accordance with the American Plywood Association (APA) speclficaDons. b, P[yw~ood sheothlng shall be contlnuous over two or more spans with grain of face plys across supports 7. All sills shall be pressure preservative treated (.4 PSF retention) GYP #2 or better, 8, Design values: Frarmin9 Lumber: DF (north) No 2 or better Fv = 95 PSI Fb 825 PSI Design values: a, Lomiinated Veneer Lumber (LVL): E = 1,900,000 PSI gv = 285 PSI Fb = 2600 PSI DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. NOTE DEEEKOBKI, ARM & KEHL ASSOCIATES, LLC, AND THERE ASSOCIATED ENGINEER ARE NOT OVERSEEING THE CONSTRUCTION OF THIS BUiLDiNG, THE USE OF THESE DRAWINGS BY ANY CONTRACTOR, SUBCONTRACTOR, BUILDER, TRADESMAN OR WORKER SHALL INSTIQATE A HOLD HARMLESS AOREEMENT BETWEEN THE DRAWING USER AND DEERKOSKI, ARM & KEHL ASSOCIATES, LLC, THE USER SHALL IN FACT AGREE TO HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC, HARMLESS FOR ANY RESPONSIBILITY IN REGARD TO CONS~TRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES AND FOR ANY SAFETY PRECAUTIONS AND PROGRAMS IN CO~NNECTION WITH THE WORK AND FURTHER SHALL HOLD THE ARCHITECT HARMLESS FOR COSTS AND PROBLEMS ARISING FROM THIE NEDLIGENCE OF THE CONTRACTOR, SUBCONTRACTOR, TRADESMAN, OR WORKMAN. THE USE OF THESE DRAWINGS ALSO IMPLIES THAT DEERKOSK[, ARM & KEHL ASSOCIATES, LLC. SHALL TAKE NO RESPONSIBILITY FOR THE PLAN USER'S FAILURE TO CARRY OUT THE ~WORK IN ACCORDANCE WITH THE DRAWING OR CONTRACT DOCUMENTS, DOCUMENT NO,'ES THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS, ALSO, THE CLIENT AGREES, TO THE FULLEST EXTENT OF THE LAW, TO INDEMNIFY AND HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HARMLESS FROM ANY CLAIMI, LIABILITY OR COST INCLUDING REASONABLE ATTORNEY'S FEES AND COSTS OF DEFENSE, FOR THE INJURY OR ECONOMIC LOSS ARISING OR ALLEGEDLY ARISING OUT OF THE PROFESSIONAL SERVICES PROVIDED UNDER THIS AGREEMENT, SAFETY NOTES: RESIDENTIAL RENOVATION & CONSTRUCTION 1, CENERAL' ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF RIVERHEAD, NEW YORK, BUILDING CODE, AND REQULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. 2. FIRE SAFETY: A, ALL BUILDING MATERIALS WHICH ARE STORED AT THE BITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A B, LOCKED AREA, C ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION D, ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS SUCH MATERIALS ARE TO BE KEPT AWAY FROM HEAT, E,ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN ADEQUATELY' VENTILATED SPACE, F,ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOSED CONDUITS. C.ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS, CONTRACTOR, AT ALL TIMES, TO ENSURE THERE IS NO NATURAL GAE LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE GAS TO BE USED DURING CONSTRUCTION, DUST CONTROL; A, DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA, B. CONTRACTOR TO ISOLATE CONTRUCTION A,REA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR C. HEAVY DROP CLOTHS. DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE ACCUMULATION. NOISE AFTER HOURS' A, CONSTRUCTION OPERATIONS WILL BE cOr~FINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, B, EXCEPT LEGAL HOLIDAYS. CONTRACTOR MUST OBTAIN WRI~EN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH INCONVENIENCES TO THE OTHER NEIGHHBORS. 6 SPECIAL SAFELY' NOTES ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE PROPERTY, EACH AS REPRESENTATIVES OF THEIIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF THE OCCUPATIONAL SAFETY AND HAZARD ACT OF~ OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR SHALL INDICATE SATISFACTION CONCERNING SAFE'TY AND FULL RESPONSIBILIT~' FOR ACCIDENTS OR DAMAGE, IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE RELATED TO HIS ACTIVITY, IF THE WORK OF OTHIER PARTIES OUTSIDE OF THE ORGANIZATION rs UPON iNSPECTION FOUND AT ANY TIME TO BE UNSAFE, HE SHOULD STOP WORK I~MEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, DAK ASSOCIATES, LLC, OR OWNER. THE BEGINNING OF WORK SHALL INDICFATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS, 7 PROVIDE SINGLE AD MULTIPLE-STATION SMOKE /ALARMS AS WELL AS CARBON MONOXIDE DETECTORS SINGLE AND MULTIPLE-STATION IN ACCORDANCE WITH STATE, FEDERAL, AND LOCAL CODES, GROUND WIND SEISMIC SNOW SPEED (mph) DESIGN LOAD CATEGORY 45 Ihs/sql( 120 mph) C DESIGN CRITERIA PRESCRIPTIVE DESIGN USES(s) AND OCCUPANCY CLASSIFICATION(s) USE OCCUPANCY RESIDENTIAL R-3 TYPE OF CONSTRUCTON (CHAPTER 6) TYPE GROUP V B HEIGHT AND FIRE AREA HEIGHT FIRE AREA HEIGHT BUILDING, THE VERTICAL DISTANCE FROM GRADE PLANE TO UNLIMITED AREA THE AVERAGE HEIGHT S STORY OF THE HIGHEST ROOF AS PER TABLE 5OS SURFACE = NA AS PER SECIIUN bt)2 OF THE BUILDING CODE OF NEW YORK STATE, TOTAL HEIGHT FROM RIDGE TO GRACE NA LUMPER SPECIES AND GRADE ALL HOUSE FRAMING MATERIAL DOUGLAS mR - LARCH #2 AND BETTER ALL EXT GECK FRAMING MATERIAL CCA NC PINE ~2 AND BETTER AREAS OF STRUCTURE CRAWL SPACE NA BASEMENT NA FIRST FLOOR NA SECOND FLOOR NA THIRD FLOOR NA tALCONY NA LOFT NA ATTIC (HOUSE)to) NA ATTIC (HOUSE)th) NA GARAGE NA ATTIC (GARAGEX~) NA BONUS ROOM NA SCREENED PORCHES NA SUNRODM NA )ECKS 500 sq/ft ]OVERED PORCHES NA ;OVERED ENTRANCE NA :OOL HOUSE/ CABANA NA JNCOVERED ENTRANCES NA (o) WITHOUT STORAGE (b) WITH STORAGE CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA DAMAGE FROM SUBJECTFRoSTDEPTHs,_O'LINETO MODERATETERMITETo HEAVY SLIGHT DECAYTo MODERATE 11 WINTER MEI~ SHIELD DESIGN UNDERLAY- TEMP, REQUIRED degrees YES FLOOD HAZARDS 198W/~998 MINIMUM UNIFORM DISTRIBUTED LiVE LOADS (In peuFds per equ~re foot) USE LIVE LOAD DEAD LOAD EXTERIOR BALCONIES 00 10 DECKS (f) 40 10 PASSENOER VEHICLE GARAGES (o) 50 (o) 10 ATTICS WITHOUT STORAGE (b,e) 10 10 ATTICS WiTH STORAGE (b,e) 20 10 ROOMS OTHER THAN SLEEPING ROOMS 40 10 SLEEPING ROOMS SO 10 STAIRS WO (c) 10 OUARDRAIL AND HANDRAILS (d) 200 (c) 10 ROOF ~0 10 o) ELEVATED GARAGE FLOORS SHALL BE CAPABLE OF SUPPORTING A 2,000 POUND LOAD APPLIED OVER A 20-SQUARE-INCH AREA b) NO STORAGE WITH ROOF ScORE NOT OVER S UNITS IN ~2 UNITS, e) INDI~OUAL STAIR TREADS SHALL BE DESIGNED FOR THE UNIFORMLY DISTRIBUTED LIVE LOAD OR A SOO-POUND CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE INCHES, WHICHEVER PRODUCES THE CREATER STRESSES, d) A SINGLE CONCENTRATION ~TH WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE ~TH SECTION R802,10,1, e) SEE SECTION R5022,1 FOR BECKS ATTACHED TO EXTERIOR WALLS TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MINIMUM SPECIFIED COMPRESSION STRENGTH (o) (lc) ~YPE OR LOCATION OF CONCRETE CONSTRUCTION WEATHERING POTENTIAL SEVERE (b) eASEMENT WALLS~ FOUNDATIONS AND OTHER CONCRETE NOT EXPOSED TO THE WEATHER 2,500 (c) BASEMENT SLABS AND INN:RIOR SLAB ON 2,500 (c) GRADE, EXCEPT GARAGE FLOOR SLABS eASEMENT WALLS, FOUNDATION WALLS~ EXTERIOR WALLS AND OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER S,O00 (d) PORCHES, CARPORTS AND STEPS EXPOSED TO THE WEATHER, AND GARAGE FLOOR SLABS S,500 (d) FOR SI' 1 POUND PER SQUARE INCH + 6,895 kpa to) AT 28 DAYS PSI (b) SEE TABLE RS01,2(1) FOR WEATHERING POTENTIAL (c) CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT TO FREEZING AND THAWING DURING CONSTRUCTION SHALL BE AIR-ENTRAINED CONCRETE IN ACCORDANCE ~TH FOOTNOTE (d) (d) CONCRETE SHALL BE AiR ENTRAINED, TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT, (e) SEE SECTION RW02 2 FOR MINIMUM CEMENT CONTENT, OCCL!PANC¥ OR UT-',!!! iS UNI.AWFUL V:/','TI KT, L/i' CERTIFICATE OF OCCLiPANCY .... APPROVED AS NOTED N~TIFY BUILDING ~;E~RTM~ , ~ ~T 2, ROUGH - FRAbI~N~, PLUMBING, 8TRAPPIflG, ELECTRICAL & CAULKING 4, FINAL. CONSTRUCTION & ELECTRICAL ALL CONSTRUCTION SHALL MFET THE ALL SIMPSON HANGERS HAVE BEEN CERTIFIED BY AN ENGINEER TO HAVE A CAPACITY EQUAL TO OR GREATER THAN TH~ REQUIRED AMOUNT CALCULATED FOR EACH CASE, NO SUBSTITUTIONS All Framing Hordwore Shown con these Plons, Unless Otherwise Indlcoted, Is Simpson Strong- Tie, No Substihutions Gte Appr~oved or Authorized. Due to the ReJotionshlps of Frroming Hardware to the other Components of t:he Structure, ony FrGmin9 HGrdwore Subs(itu(ion,s will Render These Plons Null Grid Void, onld will Result in the Ins(oiler / Contractor Assumin,g ResponslbLDty for the Design ond Performance (of the Entire System, COPYRIGHT 2011 D,A,K ASSOCIATES, LLC. ALL FLOOR PLANS AND ELFVATIONS ARE PROTECTED dNDER FEDERAL COPYRIGHT LAW, PLANS MAY NOT BE REPRODUCED WI~OUT WRITTEN AU~ORIZANON, ALL PLANS AND DESIGNS ARE T~E SOLE PROPERTY OF D,A.K. ASSOCIATES, LLC, THE RIGHT TO BUILD ONLY ONE STRUCllJRE FROM THESE PLANS IS LICENSED EXCLUSIVELY TO ~E BUYER Acceptance of these drawings does not auth0rlze the right to build without the authorization 01 local governing agencies, such os Suffolk County Dept. of Health Servmes, T0en Build,n§ Departments, DEC, FEMA, otc Verify all condNms, codes, and requirements with such agencies prior to c0nstructi0~ D°AoK ASSOCIATES, LLO 506 Main 5treel phone: (631] 767-6071 Weslhamplon Beach, New York 11778 fax. [6311466-3354 E-Mail: CArm8888@aol,com OWNERSHIP & USE OF DOCUMENTS: These drawings and speciEcaOons ~ncludin§ the therein, ore the property of D AK ASSOCIATES, tLC, No part thereof sh~ll be copied, disclosed to others or used in connection with any work or project other than for which they hove been prepored without written consenE NORK NOTES: )ROJECT: SALERNO RESIDENCE BAY AVENUE, EAST MARION, NEW YORK 3RAWINO TITLE: GENERAL NOTES SET ISSUED FOR, DATE: JULY 23, 2011 925-2011 BYr BDK CHECKED BY. JJD SHEET NUMBER: G1 JAMES d DEERKOSKI, PE ~ g 'A'~{ AS,SOCrATeS, uc NUMBER: OF REFER TO GENERAL NOTES FOR ALL STRAPPINO~ NAILINO~ FASTENING AND TIE DOWN DETAILS AgO Girder EXISONO HOUSE ---12" Song Tube rtl{ed wBh 3COB~ Cnncrete · Bottom ol Footmg to be Mk 3'-0" EXIS<NO HOUSE EXISHNO HOUSE ' lO" Sand Lube Filmed with d0~g~ Concre{e Bottom at Footing to be Mia S' O' Below Fnol Grude ACQ Girder Son[ Botl~ of Footing to be Mia B'-g' Below Fmal gmdu AXB ACQ Pas[ · IL" Sand Tube Filled with BOOB# Concrete Bo{bm al FooOng to be R{n. 3'-0" Below Fnol Grade :XlO ACQ girder Posl BoHom al FooUng to be gXd Ago Post -~2' Sand Tube Bled wBb 3000{ Concrete BoIt~ of Footing to be Mln, B'-¢ Below Rnal grade 1/2 Only Cumage Bolts (G)gXlO Ago Birder B068 EXISHNO HOUSE EXISRBG HOBSE EXISTIHG HOUSE ACO Ledger Q Post ~IB ACQ Girder of Oec~[ng /B" D/S Cedar Skirt Hoard II~BxlH ACQ SDIId Bridging IF II II ,~gXlO AgO Solid Bridging 2XIOACOGirder I~/ II II Il ,/~2x10 ACQ Solid Bridging ri II ,~2X10 ACQ Solid Bridging · 2XI0 ACQ Floor Job[s - Ig"oc Edge of Decking B/B' R/S Cedar Skirt Board -- 2210 Box H~m 4 AgO Po~t bOB8 EXISDNG HOUSE EXIS~NG HOUSE EXIS~NO HOUSE l lear Cedar Tap Clear Cedar Top Roi{ Clear Cedar Top Roil 5/g"x B" SNK Cedar Boarder ~ 2'x ¢ Clear Ced~ Top Roil 7'-d'~'," J, r'-dW ~[,~,' FOOTING AND GIRDER PLAN SCALE: 1/4": 1'-0" 306B Door ~ 2XlO ACD Girdal 2XlO ACO Floor Joists - lB"ac EXISRNO HOUSE B/B"× H" S~ Cedar 2XIO ACQ Floor Joists - 16"ac, I/2" GaN Carri0ge Bolts FLOOR JOIST LAYOUT PLAN SCALE: 1/4": 1'-0" Steps 2x12 ACQ 2x12 ACQ Outer Stringer Inner Stringer STAIR DESIGN PLAN SCALE: 1/2" = 1'-0" 5/4"x 4" S~ Cedar !210 ACQ G{rder / 2XIO ACQ Floor Joists lB ac, Top of Deck to be < SO" Above Finished Grade Beguires no Handrails II > 30' Above 12" Sono Tube FHed wBh 30oo# Concrete Bottom of Footing to be Below Frnal Grade CROSS SECTION SCALE: 1/2" = ilo'' RAIL PLAN SCALE: 1/2": 1'-0" DECKING PLAN SCALE: 1/4"= 1'-0" 5/4"x 4" SB< C~dor 2"x A" BTK Cedar BENCH PLAN SCALE: 1/2" = 1'-o" Sir'npsan HB Tydown C COPYRIGHT 2011 D.A,K ASSOCIATES, LLC. ALL FLOOR PLANS AND ELEVAtiONS ARE PROTECED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT WRITEN AUTHORIZATION. ALL PLANS AND DESIGNS ARE ?dE SOLE PROPERTY OF D.A,K. ASSOCIATES, LLC. lNE RIGHT TO BUILD ONLY ONE S~UCDJRE PROM EHESE PLANS iS LICENSED EXCLUSIVELY TO THE BUYER. Acceptance of these drawings does not authorize the right to build without the authorization of 1oral governing agencies, such os Suffolk County Dept. of Ne0lth Services, Town Bugdlng Oepor!ment!, DEC, FEMA, ekc. Verify oil conditions, codes, and requirements wNh such to construction. I (~ D°A°K ASSOCIATES, LLC 506 Main SNeer phone: (631) 767-6071 WesfhamplonBeach, NewYork 11778 fox: {631}466-3354 E-Mall: CArm8888Caol,com OWNERSHIP & USE OF DOCUMENTS: These drawings end speclflc~Uons ~ncludin9 the [dads, design end arrengements represented therein, ere the property of D,A,K, ASSOCIATES, LLC, No port thereof shell be copied, d~sclosed or project other than for which they hove been prepared without written consent, ~VORK NOTES: =ROJECT: SALERNO RESIDENCE BAY AVENUE, EAST MARION, NEW YORK )RAWING TITLE: DECK PLAN SET: ISSUED FOR: DATE: SEAL: JULY 23, 2011 BBK 4ECKED BY; JJD SHEET NUMBER: A101 JAMES d DEERKOSKI ~ D.A.K AHSOC~TIZS, ~ NUMBER: OF