CERTIFICATE OF OCCUPANCY
12/13/2011
No: 35337
Date:
12/13/2011
THIS CERTIFIES that the building
Location of Property:
SCTM #: 473889
Subdivision:
ADDITION/ALTERATION
245 PINE PL EAST MARION,
Sec/Block/Lot: 37.-4-13
Filed Map No.
Lot No.
conforms substantially to the Application for Building Permit heretofore filed in tins officed dated
3/11/2008 pursuant to winch Building Permit No. 33697 dated 3/11/2008
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
mudroom and covered porch addition and alteration to an existing one family dwelling as applied for.
The certificate is issued to Wirtz, David
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUiVIBERS CERTIFICATION DATED
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 33697 Z Date MARCH 11, 2008
Permission is hereby granted to:
DAVID M WIRTZ
60 SUTTON PLACE SOUTH
NEW YORK,NY 10022
for :
ADDITIONS/ALTERATIONS TO EXISTING ONE FAMILY DWELLING PER DEC &
TRUSTEES WITH FLOOD PERMIT AS APPLIED FOR. THIS PERMIT REPLACES BP 31117.
at pr~m~ses located at 245 PINE PL EAST MARION
County Tax Map No. 473889 Section 037 Block 0004 Lot No. 013
pursuant to application dated MARCH 11, 2008 and approved by the
FeeBUilding$ Inspector300.00to expire on SEPTE~/tu~~i~/na ~' '
ORIGINAL
Rev. 5/8/O2
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 31117 Z Date MAY 9, 2005
Permission is hereby granted to:
DAVID M WIRTZ
60 SUTTON PLACE SOUTH
NEW YORK,NY 10022
for :
ADDITIONS AND ALTER3tTIONS TO AN EXISTING SINGLE FAMILY DWELLING
PER DEC & TRUSTEES WITH FLOOD PERMIT AS APPLIED FOR
at premises located at 245 PINE PL
County Tax Map NO. 473889 Section 037
pursuant to application dated MAY
Building Inspector to expire on NOVEMBER
Fee $ 150.00
EAST MARION
Block 0004 Lot No. 013
5, 2005 and approved by the
9, 2006.
Rev. 5/8/02
ORIGINAL
Form No. 6 ~1
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOVvqN HALL r
765-1802 i ....
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and subinitted to the Building Department with the lbllowing:
A. For new building or new use:
l. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 fora0.
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accesso~j building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Ncw Construction: Old or Pre-existing Building:
Location of Property:
House No. Street
(check one)
Hmnlet
Owner or Owners of Property:
Suflblk County Tax Map No 1000, Section
Subdixision
rD ~'~ Block ,CSO~q Lot
Filed Map. Lot:
Date ofPcrmit..~_..~ t ~¢~ Applicant: '~'t~l ~
Underwriters Approval:
l'crmit No.S SC° q 3
Health Dept. Approval:
Plarming Board Approval:
Request lbr: Tcmporary Certificate
Fee Suhmitted: $ ~'1~ ~-~.
Final Certificate: ___ V (check one)
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
~)~ FOUNDATION 1ST [
[ ] FOUNDATION 2ND [
[ ] FRAMING / STRAPPING [
[ ] FIREPLACE & CHIMNEY [
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
RE.MARKS: /~~
DATE
INSPECTOR__~ ~~-
TOWN OF SOUTHOLD BUILDING DEPT.
765-t802
INSPECTION
~FOUNDATION 2ND [
[ ] FRAMING / STRAPPING [
[ ] FIREPLACE & CHIMNEY [
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
REMARKS:
DATE ~ ' INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST [ ] ROUGH PLBG.
[ ]FOUNDATION 2ND [ ] INSULATION
[ ]FRAMING / STRAPPING ~INAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
INSPECTOR
JAMES J. DEERKOSKI, P.E.
260 Deer Drive
Mattituck, N.Y. 11952
(631) 298-7116
To: Town of Southold Building Dept.
Date: November 15, 2006
Re: Insulation Inspection
Brancatto
245 Pine Place
East Marion, NY
Permit #31117
To Whom It May Concern:
After an Insulation inspection was performed on the above property, it is deemed that all
Insulation was installed correctly, and meets all building codes. Any other questions
please call.
SinCerely
es J ski
JAMES J. DEERKOSKI, P.E.
260 Deer Drive
Mattimck, N.Y. 11952
(631) 298-7116
Date: October 18, 2006
To: Town of Southold Building Dept.
Re:
Framing / Strapping Inspections
Brancatto
245 Pine Place
East Marion, NY
Permit 3 t-M 7
To Whom It May Concern:
After a Framing, and Strapping inspection was preformed on the above house, it is
deemed that all work performed was completed to plans and meets all state and local
codes. Any other questions please call.
)~al~es~J. rkoski
March 4, 2008
Southold Town Building Annex
P.O. Box 1179
Southold, NY 11971
As per conversation on Tuesday March 4 with Terry I am enclosing a check for $200.00
so that ! could get my job( Building Permit #3117) signed off and I was told it had
expired and that sending this check will open it up again so that I could get job signed off
~x~ ~and ele~ieted~ '~___~ /
Building Permit # 3117
Address 245 Pine Place
TOWN OF SOUTHOLD BUILDING DEPT.
765-11~02
INSPECTION
FOUNDATION 1ST [ ] BOUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
FRAMING / STRAPPING ~'~/FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
DATE
INSPECTOR ~" *~
L*d
h!O;d,-I blV95: E S66 !.
TOWN OF SOUTHOLD
BUILDING D~PARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www. northfork.net/Southold/
PERMIT NO.
Examined ~/
Approved
Disapproved a/c /
Expiration
,20 5
,20 '>
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
, 4 sets of Building Plans
~,/~,' ~ ~' planmng Board approval
Survey_
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Contact:
Mail to:
~ ~ ~ Phone:
.l_----- ~B'0~nsp ecto~
~l .!i - ?LICATION FOR BUILDING PERMIT
~ *r : e~pr ~STRUCTIONS
T~~ "~
a. ~s application MUST be completely filled in by t~ewfiter or in i~ ~d sub~tted to the Building hspector with 3
sets of plans, accmte plot pl~ to scale. Fee according to sch~ule.
b. Plot pl~ show~g location of lot ~d of buil~ngs on presses, relationshp to adjoi~ng presses or public streets or
areas, and wate~ays.
c. ~e work covered by this application may not be co~enced before issu~ce of Building Prat.
d. Upon approval of t~s application, the B~Iding ~spector will issue a Building Pemt to the applic~t. Such a pe~t
shall be kept on the presses available for inspection t~oughout the work.
e. No buil~ng shall be occupied or used in whole or ~ p~ for any p~ose what so ever ~til the Building ~spector
issues a Ce~ificate of Occupancy.
f. EveW building pemt shall expire if the work authorized has not co~enced wit~n 12 months a~er the date of
iss~nce or has not been completed within 18 months ~om such date. If no zoning men~ents or other re~lations affecting the
prop~y have been enacted in the interim, the Building hspector may authorize, in writing, the extension of the pe~t for an
addition six months. Threader, a new prat shall be requked.
~PLICATION IS HE,BY M~E to the Building D~aament for the issu~ce of a Building Pe~t p~suant to the
Building Zone Ordin~ce of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordin~ces or
Regulations, for the construction of buildings, additiom, or alterations or for removal or demolition as here~ described. The
applic~t a~ees to comply with all applicable laws, ordinances, building code, housing code, and re~lations, and to ad~t
authohzed inspectors on presses and in building for necessaw inspections.
( 'g nt or name, ifa co~oration)
(Ma~mg ad.ess of ap~lic~t)
,20 05
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises b~Ov/lJ'') ~ /~ ].1~]'~
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders LicenseNo.
Plumbers LicenseNo.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
House Number Street Hamlet '
County Tax Map No. 1000 Section 3~f Block 4 Lot [3
Subdivision Filed Map No. Lot
(Name)
State existing use and occupancy of premises and intended us..e and occupancy of proposed const~u~ion:
a. Existing use and occupancy ~',/P46/~1~. J~'~ . ~--: q
b. Intended use and occupancy
3. Nature of work (check which applicable): New Building
Repair Removal Demolition
4. Estimated Cost ~. 10 j (0'0 ~
5. If dwelling, number of dwelling units [
If garage, number of cars
Addition
Other Work
Fee
Alteration
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of/~ex~ting stmctures, if any: Front (~ 4 Rear ,.('"t9 5 Depth
Height. 'd-~/ Number of Stories ~ ' -'
Dimensi°ns °f same structure with alterati°ns °r additi°ns: F~untm CSt e~s
Depth Height ber
8. Dimensions of entire new construction: Front ~-~'Rear Depth
Height Number of Stories ~
Rear
9. Size of lot: Front Rear .Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated ~
12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO ~
13. Will lot be re-graded? YES __ NO -"~Will excess fill be removed from premises? YES NO__
14. Names of Owner of. pt'emise~ ~.~J ~ {Q[ ~4[]~/4kddress __ _ Phone No~ _
Name of Architect ~t~... ~,~.~ Address~~2~j~:~ ~(~'~t"-~)~2-~(.~'
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ~"/NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS,~IAY BE REQUIRED.
b. Is this property within 300 feet ora tidal weiiand? * YES ~ NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.""'
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
SS:
COUNTY OF )
~/~.~-~ ~ ~-- ~~eing duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this
.~ day of P~ c~' 20 0 d~
Not~ry-~ublic
- 'x~/~ignht:are ~f Applicant
~ State of NewY0d~
Albert J. Krupski, President
James King, Vice-President
Artie Foster
Ken Poliwoda
Peggy A. Dickerson
Town Hall
53095 Route 25
P.O. Box 1179
Southald, New York 11971-0959
Telephone (631) 765-1892
Fax (631) 765-1366
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
Permit No.: 6088a
Date of Receipt of Application: March 8, 2005
Applicant: Joanne Brancato
SCTM#: 37-4-13
Project Location: 245 Pine Place, East Marion
Date of Resolution/issuance: March 23, 2005
Date of Expiration: March 23, 2007
Reviewed by: Board of Trustees
Project Description: Construct a covered porch and mudroom on the
landward side of the dwelling and all as per plans surveyed by John Ehlers
and revised 2-28-05, with the condition of a drywell to contain roof runoff.
Findings: The project meets all the requirements for issuance of an
Administrative Permit set forth in Chapter 97 of the Southold Town Code. The
issuance of the Administrative Permit allows for the operations as indicated in the
project description.
Special Conditions: Dry well to contain roof runoff.
If the proposed activities do not meet the requirements for issuance of an
Administrative Permit set forth in Chapter 97 of the Southold Town Code, a
Wetland Permit will be required.
This is not a determination from any other agency.
Albert J. Krupski, Jr., President
Board of Trustees
James F. King, President
Jill M. Doherty, Vice-President
Peggy A. Dickerson
Dave Bergen
Bob Ghosio, Jr.
Town Hall
53095 Route 25
P.O. Box 1179
Southold, New York 11971-0959
Telephone(631) 765-1892
Fax(631) 765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
CERTIFICATE OF COMPLIANCE
it 0312C
Date: May 13, 2008
THIS CERTIFIES that the construction of a covered porch and mudroom
At 245 Pine Place, East Marion, New York
Suffolk Count)' Tax Map # 37-4-13
Conforms to the application for a Trustees Permit heretofore filed in this office
Dated 3/8/05 pursuant to which Trustees Permit it 6088A Dated 3/23/05.
Was issued, and conforms to all of the requirements and conditions of the applicable
provisions of law. The project for which this certificate is being issued
is for the construction of a covered porch and mudroom
The certificate is issued to JOANNE BRANCATO owner of the
aforesaid property.
Authorized Signature
New York State Department of Environmental Conservation
Division of Environmental Permits, Region One
Building 40 - SUNY, Stony Brook, New York 11790-2356
Phone: (631) 44-4-0365 FAX: (631) 444-0360
John P. Cahill
Commissioner
LETTER OF NO JURISDICTION
David Wirtz
PO Box 351
East Marion, NY l 193 %0351
March 12, 2001
Re: 1-4738-02819/00001
245 Pine Place, East Marion
1000-374- l-,
$CTM · '~
Dear Mr Wirtz,
Based on the information you have submitted, the New York State Department of Environmental
Conservation has determined that:
The portion of the parcel located landward of the bulkhead ( as shown on the survey by Roderick Van
Tuyl, dated March 2, 1992) is not within NYSDEC jurisdiction as shown of the NYSDEC Tidal
Wetland Map # 722-554 and infra-red photographs.
Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no
permit is required under the Tidal Wetlands Act. Please be advised, however, that no constrm:tion,
sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional
boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary
precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface
or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may
include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project
(i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm.
Please be further advised that this letter does not relieve you of the responsibility o f obtaining any necessary
permits or approvals fi.om other agencies.
cc: file
.;~ry tru~y~¥ours,
Deputy Regional Permit
Administrator
Town Hall, 53095 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Fax (631 ) 765-9502
Telephone (631) 765-1802
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
March 19, 2008
MR. DAVID WIRTZ
60 SUTTON PLACE SOUTH- APT. 14J
NEW YORK, N.Y. 10022
To Whom It May Concern:
We are unable to complete your Certificate of Occupancy because of the following
reasons:
An application for Certificate of Occupancy is not on file. (Enclosed) J
No Health Department Approval on file.
No final inspection has been made.
No Plumber Solder Certificate on file. (All permits involving plumbing being
issued after April 1, 1984) )-
Certificate of Compliance from Southold Town Trustees.
Approval of the Zoning Board of Appeals
Final Planning Board Approval.
BP #33697-Z (ADD/ALT TO DWELLING ~ 245 PINE PL. EAST MARION, NY)
No Electrical Certificate on file.
'"/The Check is not on file -$25.00
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold~ NY 11971-0959
Telephone (631 ) 765-1802
Fax (631) 765-9502
November 29, 2011
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
David Wirtz
60 Sutton Place South -Apt 14J
New York, NY 10022
Re: 245 Pine Place, East Marion
TO WHOM IT MAY CONCERN:
The Following Item(s) Are Needed To Complete Your Certificate of Occupancy:
__ Application for Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate.
~fee of $25.00. (Outdated check enclosed)
__ Final Health Department Approval.
~TPru~be~rsScS~)lrlil~a~ee~i~i~tr~i~lnPi~itT~iv~O~ii~e~lsU,~ii51119~ir 4/1/84)
Final Planning Board Approval.
Final Fire Inspection from Fire Marshall. - Bob Fisher
Final Landmark Preservation approval.
BUILDING PERMIT: 33697- Addition/Alterations to Dwelling
t606-,] 7-~/-/~ TOWN OF SOUTHOLD PROPERTY RECORD CARD
OWNER STREET
FORMER OWNER N E ACR.
S W ~PE OF BUILDING
RES. ~ I~ S~S. VL FARM COMM. CB. MISC. Mkt. Value
.....
j ' ,
FARM *cre Vol~e Pe~/ VaJue '
Tillo~J~ I~,~ I~,~e/ ,ol~,i~,
Tillable
Tillable
~oodland
Swomplond FRONTAGE ON WATER 7
House ~mot DEPTH
~ ~
Fotol ~ DOCK
~-~.
Extension
Extension
Porch
Porch
Breezeway
C~arage
Patio
O.B.
Total
COLOR
TRIM
Foundation
~ement
Fire
Type Roof
Dormer
Drivew~
/
,Io
',ecreation Room
Bath
Floors
Interior Finish
Heat
Rooms 1st Floor
Rooms 2nd Floo~
Dinette
K.
LR.
· · u"'~TH T. T.E;ILRY
OFFICE OF THE TOWN CLERK
TOWN OF SOUTHOLD
THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE
SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 24, 1993:
RESOLVED that the Town Board of the Town of Southold hereby adopts
two (2) new forms to be used under tt~e Flood Damage Prevent regulations
of the Code of the To~'n of Southold: "Floodplain Developmen~t Permit
Application" [FOP(93)]_/,~nd "Certificate or Compliance for Development in
Special Flood Hazard Area [C/C(93)].
B~DG. OF. PT
TOWN 0 F, S 0 Lri~ ,~Q~LD.._ j
Southold Town Cler-k
August 25, 1993
TOWN OF SOUTHOLD
APPLICATION
PAGE I of 4
FLOODPLAIN DE~rELOPMENT PERMIT APPLICATION
This form is to be tilled out in duplicate.
SECTION 1: GENERAL PROVISIONS (APPLICAJhrT to rcad and siKm):
I.. Ho work may start until a permit is issued.
2. The permit may be revoked if any false statements are made hereto.
3. If revoked, all work must cede until permit is re-issued.
4. Development shall not be used or occupied until a Certificate of Compliance is issued.
5. The permit will expir~ if tm work is commenced within six months of issuance.
6. Applicant is hereby informed that other permits may be required to fufftll local, state and federal regulatory
requirements.
7. Applicant hereby give~ consent to the Local Administrator or hg/her repre~entadv~ to make iea~onable
inspections required to verify compliance.
8. I, THE APPLICANT, CERTIFY THAT ALL STATEMEHTS HEREIH AND I.N ATTACHMENTS TO
, , ,., .... -/' ,!
SECTIQH 2: PROPOSED DEVELOPMENT (To be completed by APPLICA/~'T)
NAME ADDRESS TELEFHOHE
PROJECT LOCATIOiN:
To avoid delay in proce~ing the appllca6oa, please provide caou~v.h informatioa to easily idcadiy the project
Iocatiom Provide the street address, lot Dumber or legal description (auach) tnd, outside urban are-ms, the
dista~ace to thc nearest intexsectLng road or well-known [zadmazk. A sketch attached to this applJcatiott sbow~ng
thc projccl location would be bclp(a~l.
FDP(93)
A~PLICATIO N ~
PAOE 2 OF 4
DESCRIPTION OF WORK (Check aJI applicable boxes):
A STRUCTURA_L DEVELOPMENT
p, CTIVITY
-.STRUCTU R E TYPE
~'Residendal (1-4 Family)
[] Residential (More than 4 Fanaily)
[] Nee-residential (Floodproofmg? [] Yes)
[] Combined Use (Residential & Commercial)
[] Manu(actured (Mobile) Home (In Manu-
factured Home Park? U] Yes)
[] New Structure
,,i~Addltioo
[] Ahcratioa
[] Relocation
0 Demdlltion ~
[] Replacement
S'm ,V D COST OF PROSECr
B. OTHER DEVELOPMENT AC'FIVITIE. S:
O F'dl O Mining O Drilling O Grading
O Excavation (Except for Structural Development Checked Above) --
[] Watercourse Alteration (Indudlng Dredging and Channel Modifications)
O Drainage Improvements (Including Culvert Work)
UI Road, Street or Bridge Construclion
U1 Subdivision (New or Farpanxiou)
U1 Individual Water or Sewer System
[] Other (Please Specify)
After completing SECTION 2, APPLICANT should submit form to L~cal Admbxistrator for revie~v.
~;ECTFION 3: FLOODPLAIN DETERMINATION (To be completed bY LOCAL ADMINISTRATOR)
The proposed development is located on FII:/M Pa~c[ No. , Dated
The Proposed Development:
UI 1~ blOT located b I Special Hood Hazard Area (Notify the applic~xnt that the application
review b complete and NO FLOODPLAIN DEVELOPMENT PER/YflT IS REQUIRED).
~ii~ l~ located in a Special Flood Hazard Area.
FII:/.M zone deslgnalion Lq ..
100-Yea~ flood elevation at the site is: Ft. NGVD (MSL)
C] Uuava/lablc
[] The proposed devclopmem is located in a floodway.
Pq3FM Panel No Dated
C] .Sec~ection 4 (or additional instructions
. DATE / ~
APPLIC^TION n
pAGE 3 OF 4
ADDITIONAL INFORMATION REOU1 RED fT0 hc co_mplctcd by bO_CAi, ADMINISTRATOR)
Thc applicant must submit thc documents checked below before Ibc application ~ bc processed:
[] A site plan shoving Ibc Iocatio. of ail c;asdng slrucmzcs, water bodies, adjpccal roads,
dimensions and proposed dev¢lopmem.
[] Development plans, drawn to scale, and spedficadons, iacludig§ where applicablc: details for
anchoring structurex, proposed elevation of lowest floor (indudbg basement), type.s of water
resistant materials used below thc First floor, details of floodproo£mg of uLLlkies Ioca ted below
the la'st floor and details of enclos~es below the l-u-st floor.
[] Subdivision or other development plans (I[ thc subdivbioo or other development exceeds .50
lots or $ am'ex, whichever is the lesser, the applicant must provide 100-yeas flood elevations
if they axe oot otherwise available).
O Pla.~ showing the extent of watercourse relocation aad/gr [aa&form alterations.
Top of new ftll elevation
Ft. NGVD (MSL).
E3 Floodproo£mg protection level (non-residential only) Ft.: NGVD (MSL). For
floodproofed structures, applicant must attach eertificatio, from registered engineer or
[] Certification from a registered engineer that the propos~/d activity in a regulatory lloodwa¥
will not result in ~ increase in the height of the 100-year flood. A copy of all data and
caJcuJatiorts supporting this Finding must also be submitted.
[] Other:
~E(TI'ION 5: PERMIT DE'I~RMINATION (To be completed DY LOCAL ADM1NI~I'R~TQR}
I have determined that the proposed activity:. A. [] is
B. [] Is not
in conforraaace with provbious of Local Law # , 19 . The permit is issued subject to the conditions
attached to and made part of this permit.
SI O i'/ED , DATE
Fk~B_OX A i~, thc Local Administrator may issue a Development Permit upon paymeUl of designated
~ BOX. B i~ checked, thc Local Administrator wall provide a wriltcn summary of deficicncic-~. Applicant ma),
revise and resubmit an appticati0n to Ihe Local Adminislrator or may requcsl a bearing from thc Boazd of
AppeaJs
APPEALS: Appealed to Boazd of Appeals? (Z] Yes O No
Hea.r mg date:
Appeals Board Decbioo -- A. pproved? C] Yes
Co~dJtions
[] No
APPLICATION #
PAGE 4 OF 4
~E(TI'ION 6: AS-BUILT ELEVATIONS (To be submill¢d bv APPLICAHT before Cerdlical¢ of Comoliance
issued)
The fotlowlng b. formatiou mnst be provided for project structures. Thk section mnst bc completed bY a
registered professional engineer or a licensed la.nd surveyor (or attach a c~rtLficafion to this application).
Complete I or 2 below.
Actual (As-Built) Elevadoo of thc top of ~h¢ lowest lloor, bduding basement (in Coastal Hieh Hazard
Areas. bottom of lowest structural member of the lowest floor, exdudlng piling and cohmaus)
FT. NOVD 0viSL).
Actual (A&BuiJt) Elevation of floodproo£mg protection
FT. NOVD (MSL).
NOTE: Any work performed prior to s?mittal of thc above iMormation ix at the risk of the Applicant.
SECTION 7: COMPLIANCE ACTI01~ (To be completed bY LQcAL ADMINISTRATQWI
The LOCAL ADM[NISIT, ATOR will complete this section ns applicable based on inspection of the project to
ensure compliance ~th the community's local law for flood damage prevention.
INSPIECTIONS:
DATE BY DEFICIENCIES? [] YES [] NO
DATE BY DEFICIENCIES? CI YES [] NO
DATE BY DEFICLENCIES? [] YES ~ NO
SECTION [1: ~ER'FIFICATE OF COMPLIANq?E(To be completed bY LOCAL ADMINI~;TRATQR'I
Certificate of Compliance issued: DATE: BY:
Attachment B
8AMPLE
CERTIFICATE OF COMPLI~ZNCE
for Development in a Special Flood Hazard Area
DRAWING LIST
SHEET NO
LOCATION MAP
l SITE PLAN
1
DRAWING TITLE
SITE DATA
TITLE PAGE WITH SITE PL~
~ODE SHEET
PLANS AND SECTION DETAILS
DATE SCrM#
APRIL 28,2005
APRIL 28,2005
APRIL 28,2005
4 ELEVATIONS APRIL 28.2005
PROPERTYADDRESS
OWNER
LOTCOVERAGE
245 PINE PLACE, EAST MARION, NY
DAVID M. W~RTZ
ZONING R-40 NON-CONFORMING
SURVEYOR JOHN C. EFiLERS LAND SURVEYOR
6 EAST MAIN ST. RIVERHEAD, NY, 11903.
369-8288
BUILDING HEIGHT ALLOWABLE - 35 FEET
ACTUAL- 20'-0"
ENERGY CODE BUILDING .EXCEEDS MIN. REQUIREMENTS SET FORTH BY N,Y.
STATE RFSIDENTIAL BUILDING CODE · SEE ATTACHED REPORq'
DESIGN CRITERIA
TYPE OF CONSTRUCTION - WOOD PLATFORM FRAMING - DOUGU~ FIR #2
SNOW LOAD- 45 PSF.
FIRST FLOOR- LL 40 PSF.
SECOND FLOOR - LL 30 PSF.
WIND SPEED - 120 MPH.
FROST LINE DEPTH - 36"
SEISMIC ZONE- B
WEATHERING - SEVERE
TERMITE DAMAGE- MODERATE/HEAVY
DECAY - M OD/H~/Y
ICE SHIELD UNDERLAYMENT REQUIRED
LEGEND
SYMBOL
ABBREVIATION
DESCRIPTION
SECTION SYMBOL
SECTION NUMBER
SHEET NUMBER
ELEVATION SYMBOL
ELEVATION NUMBER
SHEET NUMBER
DETAIL FLAG SYMBOL
DETAIL NUMBER
SHEET NUMBER
COLUMN LINE
ELEVATION MARK
EQUIPMENT NUMBER
REVISION SYMBOL
WINDOW
SYMBOL
IXl
DOORNUMBER
PARTITION TYPE
GYPSUM WALL BOARD
METAL
CONCRETE (SECTION)
ROUGH WOOD BLOCKING
SECTION)
WOOD BLOCKING
SECTION)
FINISH WOOD
)LYWOOD (LARGE SCALE)
NEW WALL
EXISTING WALL
DEMOLISH WALL
INSULATED WALL
AMP,
AHCH.
A,SME
ASlM
BB.
BLIP.
BM.
R,O,
UUI,
UIU.
DAB.
[;LU
[;ER.
[;L.r L
UUNU.
[;UNSh
[;UN I.
[;uv'G
CU FI
GU IN
CO YU
B
DBL
gN° L CODES_O_F_ _ " )APPROVED AS NOTED
NOTIFY BUILDING D.PARTMENT AT
A/lA SOUTHOLDTOWNPL.~NNINGBOARD 765-1802 DAM TO 4PM FOR THE .
~/~.,¢'~JfiA/.~'~LC~f/~'O U T H 0 L D TOW N T R U ST E ES FOLLOWING INSPECTIONS:
-- 1. FOUNDATION - TWO REQUIRED
~'~2./~ /V.//~ N.Y.S. DEC FOR POURED CONCRETE
% 2. ROUGH- FRAMING & PLUMBING
3. iNSULATION
4.FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C.O.
~ ALL CONSTRUCTION SHALL MEET THE APRmL2a 200S
REQUIREMENTS OF HE CODES OF NEW
YORK STATE. NOT {ESPONSIBLE FOR
DE8IGN OR CONS' {UCTION ERRORS.
O* COMPLY WITH CHAeTEh-"46"
FLOOD DAMAGE PREVENTION
SOUTHOLD TOWN CODE.
OCCUPANCY OR
US.E NLAWFUL
"--WIT 'CERTIFICATE
iCCUPANCY ALL CONSTRUCTION SHALL
MEET THE REQUIREMENTS OF
STORM WATER ! CODES OF NEW YORK STATE.
RSUANT TO SECT ON 45-10C CE
I-HE ~ oWN
OODE,
NAILING & CONNECTIONS
UNOERWBI~RS CERTIFICA1E!
REQUIRED
Above Finished Cetlin~
A~ove tinisnee Hoor
American InstCwte of Ammtects
American Instrtute ct uectncal Engineers
American InSatute of uteel Construction
Aluminum
Alternate
DEFI'. Department
DH., DTL Detail
DIA, ,(~ Diameter
DIAG. Dia~onal
DIM.. DIMEN Bimension
DH Down
DR(SI Doorfs)
urw~., UWU Urawct~
FLbV. Uevation
INT. Interior
KW Kilowatt
L LenR~h
LAV. Lavatory
Pound
Linear
LT, Lil~t
MANUF. Manufacture
~AT'L Material
Pair
~ual~y
adius
I SPEC.iS) Soaeifie~tian
SO. ' ' S~uare
STD. Rtandard
STL Steel
STRUC Structure
Am re
Arc~ect
Arr~rican ~ociety at Heating, HefriKeratJee
Air Condmoning Engineers
American Uoclsty nt Mechanical bnglneers
AUIM American 3OClatytor lestlnI[MaterlalS
uoam
UlOCK
Beam
uy umem
uattom
8BtiStl Thermal URn
CobJnat
Co,lng
~ersmlc
[;UBIC Peet Per Minute
[;enterllne
ClOSat
clear
Column
Continuous
bLb[;, EleCtrical
EN{J. Engineer
P, Eqmoment
UC'c(nc water Cooler
EXH ~xnauat
bRIUI. ~stlng
~xP ~pese~
FIN, Hnmsn
hE, ~, FlOOr
PP, P~repmor
h~m
GAL 6allOn
~V. ~al~nlz~
UC General ~ntm~or
GWB G~um Wall Boara
HUWH amware
H.M. HOllOW M~I
HURI~ HOrlzon~l
MAX. Maximum
MECH. Mechanical
Covering
Center
CUbiC Peat
[;uOic Inca
[;uDic Yard
Deptl~
Double
HH Hour
HW HOt water
I.U. Inside Diameter
IN. Inch
INCL Ioolube/lncluding
INFO. Information
INSUL
Minimum
Meml
Norm
National EleCtrical COOe
Notlncontrsct
Numoer
Not To 6came
uverall
Overall Dimension
Pemendicular
Phase
Plate
POliShed
Founds peruquare FOOt
PoundsperSquarelnch
Painted
Width. Wide
With '
Water Cl~nt
WD Wood
Zl.![
a IJJ. to
loint DescriptionNail Sizes I Nail Spacing
ROOF FRAMING
3- 8d per rafter
Rafter to Ted Plate (Toe-nalked) 3 - 8d per joist
Ceiling Joist to Top Plate (Toe-nailed) 3 - 1stl each lap
COliIn8 Joist to Parallel Rafter (Face-nailed} 4 - 16d each lap
Ceiling Joist Laps over paftlUons (Face-nailed) 2 - Bd per Ue
Collar Tie to Rafter (Face-nailed) 2 - 8d each end
Blockln¢ to Rafter (Tee-nailed) 2 - 16d each end
Rim Board to Rafter (End.ailed)
ALL FRAMING
Top Plate to Top Plate (Face-nailed) 2-16d per foot
Top Plates at Intersections (Face-nailed) 4 - 16d ]olnts-each side
Stud to Stud (Face-nailed) 2 - lsd 24' o~
Header to Header (Facealalled) ~.6d 16' C.C. along edges
TOp er Sottam Plate to Stud (End-nailed) 2 - 3.6d per 2x4 stud
2 - 1Ed per 2xS stud
2 - 16d per 2x8 stud
Bottom Plate to Floor Jolst,Bandlolst. EndJo[st or Blcckln8 2 - d6d per foot
(Face-nailed)
FLOOR FRAMING
Joist to SIIh Top Plate or Girder (Tee-nailed) 4 - 8d per
Bfidgin¢ to Joist (To.nailed) 2 - Bd each end
BlocHng 'co Joist (Toe-nailed) 2 - 8d each end
Blocking to Sill or Tofi Plate ( Toe-nailed) 3 - 16d each bloCk
Ledger Stdp to Beam (Fac~-nalled) 3 - [6d each Joist
Joist on Ledger to Beam (Toe-nailed) 3 - Bd per Joist
Band JoiSt to Joist (End-nailed) 3 - 16d per Joist
Send Joist to Sill or Top filate (T~e-nalled) 2 - 3.6d ~ per foot
ROOF SHEATHING
Structural Panels 8d 4' c.c. eddmeter zone
other 6" C.c. edges of
panel, 12' c.c. Interior
of psnel
Dla~onal Board Sheathing
1' x S' or 1' x S' 2 - 8d per suppsrt
1' x 10' or wider 3 - 8d der suppsrt
CEILING SHEATHI
Gypsum Wallboard 5d 7' edge / 3.0' field
WALL SHEATHING
Structural Panels 8d (see table 3.9)
Frberbeard Paners
25 / 32" 8d 3" edge / 6" field
Gypsum Wallboard 5d 7' edge/10" field
Hardboard 8d (see table 3.9)
Pa~clebeard Panels 8d (see table 3.9)
Diagonal Beard Sheathing
1" x 6" or 1" x 8" 2 - 8d per suppsrt
1' x 10" or wider 3 - Bd per suppoft
FLOOR SHEATHING
Structural Panels
1" or less Bd 6" edge / ~2" field
greater than 1" J~stl 6" edge / 6" field
Diagonal Beard Sheathlns
3.' x 6" or 1" x 8' 2 - 8d per support
GENERAL NOTES
3.. ALL WORK MATERIAL, AND EQUIfiMENT SHALL BE IN
ACCORDANCE WITH THE NEWYORK STATE UNIFORM
BUILDING CODE, AND THE NEW YORK STATE ENERGY
CONSERVATION CODE, AND LOCAL ALffHORTIIES.
2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A
MINIMUM 28 DAY STRENGTH OF 3000 RSI
3. ALL LUMBER SHALL BS GHADB STAMPED DOUGLAS RR'
LARCH STRUCTURAL GRADE #2 OR BETTER.
4. PROVIDE DOUBLEHEADERSANDTRIMMERS AT ALL
STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL
PARTITIONS, EXCEPT AS NOTED ON DRAWING,
5. BRIDGING TOBEPROVIDEDFORALL JOISTS AND
FLOOR BEAMS. SPADING NOT TO EXCEED B.O Pr,
6. ALL DIMENSIONS ANDGRADECONDITIONS TO BE
VERIFIED BY CONTRACTOR(S) PRIOR TO START OF
CONSTRUCTION AND ORDERING OF MATERIALS. THIS
FOUNDATION H~S BEEN DESIGNED FOR A SOIL
BEARING CASACFlY OF IWO (2) TSF AND GRADES
LESS THAN 5%. CONTRACTOR SHALLVERIFY THAT
THESE CONDITIONS ARE MET. ALL FILL BENEATH
CONCRETE SLABS TO BE COMPACTED TO 95%
RELATNE DENSITY,
7. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE
SUPPORTED BY DOUBLE UPRIGHTS, 9.0 FT AND OVER
BY TRIPLE UPRIGHTS. ALL HEADERS TO BE
MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING.
8. PROVIDE FIRESTOPPINS AT ALL LEVEL
PENETSAllONS
9. PROVIDE FLASHING AT ALL ROOF BREAKS,
CHIMNETS. SKYLIGHTS, EXTERIOR DOORS~ WINDOWS
AND DECKS ETC..
10. DO NOT SCALE DRAWrNGS.
3.1, DESIGN CONSULTANTS OR RECORD ARCHITECT-
ENGINEER ARE NOT RESPONSIBLE FOR THE
INSPECTION, SUPERVISION, OR ADMIN!STRAIION OF
THIS CONSTRUCTION PROJECT. FEDERAl. STATE
AND LOCAL ZONING AND BUILDINS CODE SOMPEANCE
SHALL BE THE RBSPONSIBIUTY OF THE
CONTRACTOR.
12. THIS DRAWING lEAN INSTRUMENT PREPARED TO
FAClUTATE CONSTRUCTION AND SHALL NOT BE
CONSTRUED AS A BON1TIACT BE3%VEEN BUILDER AND
OWNER.
13. SEWAGE DISFOSAL STSTEM AND FRESH WATER SUPPLY
SHALL BE DESIGNED AND BUILT IN ACCORDANCE
WITH THE SUFFOLK COUNTY DEPARTMENT OF HFIALTH.
14. THIS STRUCTURE HAS BEEN DESIGNED IN
ACCORDANCE WITH THE NEWYORK STATE ENERGY
CONSERVATI0N CODE.
15. ARCHITECT TO BE NOTIFIEDINWRITING OF ALL
CHANGES PRIOR TO AN D DURING CONSTRUCTION.
3.6, ALL BTRUCTdRALSTEELTOSEASTMAS6WITHONE
COAT EpoxY PNNT. ALL FASTENERS TO BE ~STM
A~325 BOLTS, 3/4' DIAMETER.
17. CONTRACTOR SHALL OBTAIN ALL PERMITS AND
INSURANCE NECEDEARYTO PROTECTTHE ENGINEER
AND OWNER.
18. DO NOT BACKFILL AGAINST FOUNDATtON WALLS
UNTIL FLOOR SYSTEM INSTALLATION IS COMPLETE.
3.9. PROVIDE CARBON MONOXIDE ALARMS ON EACH LEVEL
AND tN BASEMENT ( IF APPLICABLE ). po~ftiON NEAR
ENTRY FROM HOUSE TO AI'rACSED GARAGE AREA.
20. SMOKE DETECTORS REQUIRED IN EACH BEDPOOM AND
ON EACH LEVEL OF DWELLING AS REQUIRED BY
NEW YORK STATE BUILDING CODF-
23.. ANY ALTSHATION~ REPAIR, ADOmON OR CONVERSION TO
AN EXISTING DWELLING REQUIRING A BUIL~NS PERMIT
NOW REQUIRES THAT ALL SLEEPING ROOMS IN THE
HOUSE BE UPGRADED WITH HARD W~RBD &
INTERCONNECTED SMOKE ALARMS.
22. THE NYE CODES ALSO APPLY TO ACCESSORY
STRUCTURE DESIGN.
23. GARAGE DOORS TO BE RATED FOR ~TO MPH. WIND LOAD
FRAMING NOTES
ALL FRAMING LUMBER SHALL BE GRADE STAMPED
DOUGLAS RR-LARCH STRUCTURAL GHADE No. 2 OR
NNL PLYWOOD BUBFLOOR TO FLOOR JOISTS.
ICE SHIELD UNDERLAYMENT
REQUIRED - 24' FROM EDGE
IMESON H2.5 A
HURRICANE CLIP · 18" O.C.
HURRICANE CUP
TYPICAL
EXYENDTOTOPOFTOP
s'nJDS
EXTERIOR EDGE OFALL
SHEATHING.
7 METAL S~P
0 JACK POST
MST27 0 STUDS
w/4 - 8d NAILS 048" O.C.
EACH END - TYP.
PLYWOOD SHEATHING
TO OVER LU= BOX
BEAM -TOP + BoTroM.
----FLOOR JOIST
HEADER
' METAL STRAP
0 JACK POST
W/4 - SU NAILS 048'
EACH END -TYP.
SIMPSON MST27
1 1/2" WIDE - 20 GAGE
WRAP
(4~4d NAILS)
AROUND SILL PLATE
AT ANCHOR BOLT
SIMPSON MSTZ7
1 1/2" WIDE - 20 GAGE
METAL STRAP 048' OC,
2 - #5 REBAR
SE~ DWGS.
FOR DESIGN.
TO SILL PLATE
8d NAILS 0 4" O.C.
SECTION
ELEVATION
'OP OF ESUNDAT]ON
HOLD DOWN + SHEAR CONNECTION CRITICAL PATH
ROOF PLAN
PROVIDE 8d COMMON NNLS 0 4' O.C,
AT HIGH PRESSURE ZONE - 6" O.C
AT ALL OTHER POET~ONS OF ROOF
TYRCAL
PROVIDE 8d NAILS · 4" O.C. AT PERIMBI~R INIERIOR
EDR~ONS OF PANELS IN HIGH PRESSURE ZONES.
O( 10'
GABLE ROOFS
O~ 10°
COMPONENT AND CLADDING PRESSURE ZONES
WINDOWS - GLAZED OPENING
PROTECTION IS REQUIRED FOR ALL GLAZED AREAS IN
ACCORDANCE WITH LARGE MISSILE TEST OF ASTM E 1996
AND ASTM 1888. CONTRACTOR MAY USE WOOD STRUCTURAL
PAN ELS IN LIEU OF THE ABOVE MEN110NED WINDOWS. PANEL
DETNLS SHALL BE AS FOLLOWS
MAX.
/2" WOOD SCREWSO12" O,C. SET I1~
PANEL
* LARGER PANELS TO BE
CUSTOM DESIGNED,
PAN ElS TO BE PRECUT TO FIT OVER WINDOWS WITH
HARDWARE PROVIDED FASTENERS TO BE DESIGNED TO
ALIGN WiTH WINDOW JACK POSTS, HEADER + SILL PLATE,
PANELS TO BE MAINTAINED ON SITE, LABES LOCATIONS ON
EACH PANEL
l.d
/
KffCHEN
EL 3.2"
EXIST. LIVING ROOM
EXIST. KITCHEN
4Ro PLAN
1/4"=1'-0"
:q
~EY ON TOP OF
EXIST. ROOF SHEATHING
EXIST. MASONRY OPENING
FURR OUT WALL
TW2104~
EXIST, DOOR TO
EL 8'
COVERED PORCH
HB+G 12" DIA. ROUNDTUSCAN
COLUMNS
FIRST FLOOR PLAN
1/4"='1'-0"
GIRDER
UP 8"
EL 0
5c7' 5'-7'
SKYLIGHT
A~OVE
EXIST. GARAGE
KNEE WALL OVER
EXIST. WALL FRAMING
BY OWNER
EXIST. DORMER
FLUSHING
SKYLIGHTFOR
SHALLOW SLOPED
ROOF (45 ~"x30~
MUDROOM
/
/
EL. O"
COMPACTED
BACKFILL
SECTION DETAIL
3/8"=1'-0"
MEMBRANE ROOFING ON ICE AND WATER
SHIELD ON CONT. SOFRT VENT W/INSECT
SCREEN ON 30# BLDG. FELT ON 5/8
PLYWD. SHEATHING ON 2x6RR~IB' O.C.
W/R-30 BAST. INBULAffON
FORCONCRETE
FUUNO. WALL
-NEW KNEE WALL OVER EXIST. WAU.
FRAMING BEYOND
AND INSTALL N
TYP. EXTERIOR WALL
CONSTRUCTION:
CEDAR SI
PAPER ON 6/8 PLYWD.
SHEATHING ON 2x6 WD.STUD~
16' O.C. W/R-21 RAST. ~NSUL 5/8
DRYWALL TAPED AND SANDED
~EWALL
BITUMINOUS DAMP
PROOFrNG
:5 BARS CONT.
B'x16" P.C. FOOTING
NOTE:
ALL FLOOR FRAMING TO
BE ACQ TREATED
mAI'rING SIDING
~VER EXIST.
~RICK WALL
~IRDER
BEYOND
SECTION DETAIL
LEVEL DOWN
GRADE +/- 6" TO
PLACE GIRDER
CONSTRUCTION TO
REMAIN
6 SECT~ION DETAIL
1"-1'-0"
FLUSHING ~ 4' P.C W/Bx6 ~
~--- SLAB (')N GRADE ~
HB+G WOOD ~2." ~
ROUND TUSCAN
COLUMN
SIMPSON # STRR//2 HOLLOW
COLUMN UPLIFT CONNECTOR-SET
IN BONO'lUBE
UNE OF DECK
~2" SONSTUBES MIN. 3'-0"
BELOW GRADE SET ON
UNDISTURBED SOIL, 'rfP,
61~4"
6c7" 6'-4"
WALL ON 8X 16 PS
FOOTING MIN. 36"
11,.4,PEEP
NOTE:
ALL FRAMING TO BE
ACQ TREATED
FOUNDATION PLAN
NOTE:
ALL FLOOR FRAMING TO
BE ACQ 'HREATED
LEGEND
EXISTING WALL
DEMOLISH WALL
IEDRST.
DORMER
- EXIST, ROOF BEYOND
SKYLIGHT
NEW BOARD & BATON ~
HB+G :[2" DIA. ROUND 11JBCAN
COLUMNS
MATCH EXIST. WOOD
BHINGLES -
DOORS AND GABLE MATCH EXIST. 'I~IM
WEST ELEVATION
HB+G ROUND WOOD
TUSCAN COLUMN
NEW BOARD &
BATRNG BIDING
IOOD
DECK
SHINGLES
MATCH EXIST.
TRIM
NORTH ELEVATION
APRIL 282005 PE~Mlnr
ELE'~ATIONS
4