CERTIFICATE OF OCCUPANCY
No: 35279
Date:
11/7/2011
THIS CERTIFIES that the building
Location of Property:
SCTM #: 473889
Subdivision:
RESIDENTIAL ADDITION
1040 FOUNDERS PATH SOUTHOLD,
Sec/Block/Lot: 64.-2-15
Filed Map No.
Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
9/23/2009 pursuant to which Building Permit No. 35017 dated 9/23/2009
was issued, and conforms to all of the requirements of thc applicable provisions of the law. The occupancy for
which this certificate is issued is:
second floor addition to an existing one family dwelling and non-habitable second floor addition garage as applied for.
The certificate is issued to
Smith, Justin & Smith, Susan
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
9/20/11
35017 10/14/11
~/ John W Rcig~h~ert
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. ~ Z Date SEPTEMBER 6,
2007
Permission is hereby granted to:
JUSTIN & SUSAN SMITH
1040 FOUNDERS PATH
SOUTHOLD,NY 11971
for :
SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY DWELLING W/O
NEW ENTRY OR SECOND
STORY OVER GARAGE.
1040 FOUNDERS PATH
Section 064 Block
at premises located at
County Tax Map No. 473889
pursuant to application dated AUGUST
ova'"
SOUTHOT,D
9, 2007
0002 Lot No. 015
and approved by the
Building Inspector to expire on MARCH 6~~
Fees 449.20
ORIGINAL
Rev. 5/8/02
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 35017 Z
Date SEPTEMBER 23, 2009
Permission is hereby granted to:
JUSTIN & SUSAN SMITH
1040 FOUNDERS PATH
SOUTHOLD,NY 11971
for :
SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY DWELLING W/O
NEW ENTRY OR SECOND STORY OVER GARAGE. THIS PERMIT REPLACES 33363.
at premises located at 1040 FOUNDERS PATH SOUTHOLD
County Tax Map No. 473889 Section 064 Block 0002 Lot No. 015
pursuant to application dated SEPTEMBER 23, 2009 and approved by the
Building Inspector to expire on MARCH 23, 2011.
Fee $ 449.20
Authorized Signature
ORIGINAL
Rev. 5/8/02
Form No. 6
TOWN OF SOUTItOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF occUPANcy
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic featurfs.
2. Final Approval from Health Dgpt. of water supply and sewerage-disposal (S-9 form).
3. Approval ofelectrieal installation from Board 6fFire Underwriters.
' 4. '8w. om statement from plumber certifying that the solder used in ~yatem contains less than 2/10 of t% lead.
5. Commercial building, industrial building, m~tiple residences and similar buildings and installations, a certificate
of Code ComPliance'from architect or engineer responsible for the building~
.6. Submit planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) don-conforming useS, or buildings and "pre-existing" land uses'.'
1. Accurate survey of property showing all property lines, streets, building and. unusual natumJ or topographic
features.
2. A properly c--gmpleted appiicati0n and consent to inspect signed'by the applicant. Ifa Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming po01 $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00,
~. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy- $:25
. 4_ Updated Certificate of Occupancy- $50.00
· 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Date.
New Construction:
Location of Property:
Old or Pre-existing Building:
Hous~ No.
Owner or Owners of Pwporty:
Suffolk Co.unty Tax Map No 1000, Section
Subdivision
Permit lqo. ~ ~0 I '"'] Dat~ of Permit.
(check one)
Street Hamlet
Ffl~ Map. ~t:
Health Dept. Approval:
Planning Board Approval:
Undervaiter~ Approval:
Request for: Temporary Certificate
.Foe Submitted:$ '- ~"~
Final Certificate:
~ (check one)
Applicant S gnatfire
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold. NY 11971-0959
Telephone (631) 765-1802
Fax (631) 765-9502
rofler, richert~,town.southold.n¥ us
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
ssued To: Justin & Susan Smith
~,ddress: 1040 Founders Path City: Southold St: NY Zip:
~uilding Permit #: 35017 Section: 64 Block: 2 Lot: 15
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
3ontractor: DBA: Custom Lighting of Suffolk License No: 38893-me
SITE DETAILS
office Use Only
Residential [~ Indoor ~ Basement ~ Service Only ~
Commerical Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Wall Fixtures Smoke Detectors
Service 3 ph Hot Water GFCI Recpt
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel NC Blower Range Recpt Fluorescent Fixtur~u Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches Twist Lock Exit Fixtures ~ TVSS
Other Equipment: 1-paddle fan, 1-exhaust fan
Notes:
Inspector Signature:
Date: Oct 14 2011
81-Cert Electrical Compliance Form
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, blew York 11971-0959
Telephone (631 ) 765-1802
Fax (631) 765-9502
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATION
Building Permit No.
Owner: '? 3 a ·
(Please print)
Plumber:
(Please print)
Date: j / [/
I certify that the solder used in the water supply system contains less than 2/10 of 1%
Sworn to before me this ,~o~ .~/2~{-
dayof~, 20 1{
(Plumbers Signature)
WENDY L. KUKLA
Public, 8rate of New Yo~
No. 01KU6176871
C Qualified in Suffolk County
ommission Expires 11/051201
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST
[ ] FOUNDATION 2ND
[ ] FRAMING / STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] ROUGH PLBG.
[ ] ~LATION
[~FINAL
[ ] FIRE SAFETY INSPECTION
] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
DATE --~/~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST
[ ] FOUNDATION 2ND
[ ] FRAMING / STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPE~"I'ION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ~ ELECTRICAL (FINAL)
REMARKS:
DATE
INSPECTO~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST [ ]ROUGH PLB~G.
[ ]FOUNDATION 2ND [ ]IN~J~I~N
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY ~ ]FIRL=~AFE'rY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION [ ]FIRE RESISTANT PENETRATION
[ ]ELECTRICAL (ROUGH) [ ]ELECTRICAL (FINAL)
DATE
INSPECTOR_~ ~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [~ ]~ULATION
[ ] FRAMING/STRAPPING [I~]~FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) , ] ELE~,.tCAL (FINAL)
REMARKS:
DATE
INSPECTOR
FOUNDATION (1ST)
FOUNDATION (2ND)
ROUGH FR2LMING &
PLU'NIBING
~S~ATION PER N. Y.
STATE E~RGY CODE
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www. northfork.net/Soutb Ad/
PERMIT NO. 3'"~:> ~ :~
N
BUILDiNG PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey.
Check
Septic Form
'! N.Y.S.D.E.C.
~/ ~ ~'1 Trustees
Examined 1~~,20 ¥,~ ff~ , I~{ Contact: .
~t~I/ " -~i, ~~to~
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on promises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Deparlment for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. ~_~x [~~x~ ~)~
(Sigh~t_a~e of applicant or name, ifa corporation)
' (Mailing address °f'appiidant) ~149~018
· . ,//p?,
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electncmn, plumber or builder
Nameofownerofpremises dU.~-'']~ :' ~ Y~/~,/'// /:dt/c~/'~
(As on the tax roll 6r latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
Location of land on which proposed work will be done:
loVE} /7 r/-/
House Number Street
County Tax Map No. 1000 Section 4 {/
Subdivision
Hamlet
Block ~--
Lot/d'
Lot
Filed Map No.
(Name)
2. State existing use and occupancy of premises and intended use and occupancy ~ fproposed construction:
a. Existing use and occupancy 0 ~~'
b. Intended use and occupancy ~~~,~
3. Nature of work (check which applicable): New Building Addition 2 ~fl ~ ~/dx31i~Alteration
Repair Removal Demolition Other Work
t~,cscription)
4. Estimated Cost~"(~('~/(~(~, Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front -~(~
Height / (~ Number of Stories
Rea
Dimensions of same structure with alterations or additions: Front
Depth. Height Number of Stories
8. Dimensions of enti~ n~ew construction: Front :~ ('~e'O~ff ~ Rear ~:~/'~,~ac ~
Height "~ -6 Number of Stories
Depth
Rear
.Depth "2
9. Size of lot: Front
Rear .Depth
10. Date of Purchase
Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO__
13. Will lot be re-graded? YES__ NO ~"'Will excess fill be removed from premises? YES__
14. Names of Owner of premises
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO ~
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
NO ~
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
SS:
COUNTY OF.5~s~,e-~lk, )
~o.-x,~,.o 0,x ~ r~z ~L ~ being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this
~+~" dayof ~ o,~ .~ ~r 200~
~ Notary Public ~ (~
John M. Judge
NOTARY PUBLIC, State of New York
No. 01JU6059400
Qualified In Suffolk County
Commission Expires May ~9, 20 ~
Signature of Applicant
Town Hall Annex
$4,375 Main Road
P.O. Box 1179
Southold, ~ 1197b0959
Telephone (631) 765-1802
BUILDING DEPARTMENT
TO'tN OF SO UTHOI$1
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY:
Company Name:
Name:
License No.:
Address:
Phone No.:
*Name:
*Address:
*Cress Street:
*Phone No.:
Permit No.:
Tax Map District:
Date:
%/.
JOBSITE INFORMATION: (*Indicates required information)
1000 Section:
*BRIEF DESCRIPTION OF WORK (Please Pdnt Clearly)
Block: OLOLO (~ Lot: (~_ ~5"
(Please Circle All That Apply)
*Is job ready for inspection:
*Do you need a Temp Certificate:
~ NO Rough In
YES / NO
Temp Information (If needed]
*Service Size: 1 Phase
*New Service: Re-connect
Additional Information:
82-Request~rlnspection Form
3Phase 100 150 200 300 350 400
Underground Number of Meters Change of Service
PAYMENT DUE WITH APPLICATION
voo lJ Itu
Other
Overhead
Town of Southold
Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM
PROPERTY LOCATION: B.C.T.M. #:
District Section Block Lot
THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A
8TORM-WATER~ GRADINGr DRAINAGE AND EROSION CONTROL PLAN
CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK.
Item Number:
(NOTE: A Check Mark (~) for each Question is Required for a Complete Application) Yes
Will this Project Retain All Storm-Water Run-Off Generated by a Two (2") Inch Rainfall on Site? ~_E.l~_~$ __
No
2
3
4
5
6
7
8
9
(This item will include all mn-off created by site clearing and/or construction activities as well as ail Site
~mprovements and the permanent creation of impervious surfaces.)
Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location?
This Item shall include all Proposed Grade Changes and Slopes Controlling Surface Wated%w!
Will this Project Require any Land Filling, Grading or Excavation where there is a change to the Natural
Existing Grade Involving more than 200 Cubic Yards of Matedal within any Pamel?
Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of
Five Thousand (5,000) Square Feet of Ground Surface?
Is there a Natural Water Course Running through the Site?
Is this Pmject within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach?
Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vedical Rise to
One Hundred (100') of Horizontal Distance?
Will Driveways, Parking Areas or other Impervious Surfaces be Sloped to Direct Storm-Water Run-Off
into and/or in the direction of a Town right-of-way?
Will this Project Require the Placement of Material, Removal of Vegetation and/or the Construction of
any Item Within the Town Right-of-Way or Road Shoulder Area?
(This Item will NOT include the Installation of Driveway Aprons.)
Will this Project Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercourse?
NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark in the Box, a Strum-Water, Grading,
Drainage & Erosion Control Plan is Required and Must be Submitted for Review Prior to Issuance of Any Building Permitt
EXEMPTION: Yes No
Does this project meet the minimum standards for classification as an Agricultural Pmject?
Note: ~fY~uAnsweredYest~th~sQuest~~n~aSt~rm~~ater~Grading~Dra~nage&Erosi~~c~ntr~~P~anisN~TRequIred~ ~ --
STATE OF NEW YORK,
COUNW OF ................... SS
That I, .....~.....~..:....~....~...~'ou~ ........................... being duly swom, de'poses and says that he/she is the applicant for eernfit,
(Name of individual signing Document)
Sd t~at he/she is the .... .~._.u~...n...~..r'~. ..........................................................................................................................................
(Owner, Conlractor, Agent, Corporate Of~cer, etc.)
Owner and/or representative of the Owner of Owner's, and is duly authorized to perform or have performed the said work and to
make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and
that the work will be performed in the manner set forth in the application filed herewith.
Sworn to before me this;
.................... . ..0[. ..................... day of ....~...~.. ................ 2 .(~....'~
FORM -
(~$sion [ ~:, ..__
TOWN OF SOUTHOLD OPERTY RECORD CARD
FORMER OWNER
~s. ~/4 ~EAs.
IMP.
Tillable 2
Tillable 3
Woodland
STREET
N
VILLAGE
E
W
VL FARM COMM.
TOTAL DATE
Swampland
Brushland
House PInt,~ ,..
DISTRICT S.UB.
ACREAGE
TYPE OF BUILDING
LOT
REMARKS
Total
Extension ~ ~ ~. I 0 z b%r) ( Basement
~ ) ~t. Wallsj ~.: /~ Interior Finish
Extension .~ ~ I f) - ~0 '
ExtenSiOn ~c~ (~ [~ z ~o~ 7~ Fire Place :
, Porch Attic
/O ~ E-- ,~ (? /% &¢~,~ ~ Rooms Ist Floor
Breezewa,, ¢% ¢ z ,,., (¢ :: Z ~ Patio Rooms 2nd Floor
Garage .~Z~ ~ ~Z,~6 I O0 ~' Driveway
O.B.
FORM NO. 3
NOTICE OF DISAPPROVAL
DATE: July 29, 2011
TO: Joseph Fischetti for
Justin & Susan Smith
P O Box 616
Southold, NY 11971
Please take notice that your application dated September 9, 2009
For permit for an addition & alteration to an accessory garage at
Location of property 1040 Founders Path, Southold, NY
County Tax Map No. 1000 - Section 64 Block 2 Lot 15
Is returned herewith and disapproved on the following grounds:
The proposed construction~ to this accessory garage, is not permitted pursuant to Article
IV~ Section 280-18 which states:
No building or premises shall be ... altered in the R40 District unless the same
conforms to the requirements of the Bulk Schedule... with the same force and effect as if
such regulations were set forth herein in full.
The required f~ont yard setback for this lot is 40'.
The proposed second floor setback is 34.1'.
In addition, the proposed construction is not permitted pursuant to Art. IIl Sec. 280-15
The maximum allowable height is 22'
The proposed 2ncl floor addition will be 25' in height.
Patricia Conklin, Permit Examiner
PROFESSIONAL ENGINEER
1725 HOBART ROAD / PO Box 616 SOUTHOLD, NEW YORK 11971
TEL:631.765.2954. FAX:631.614.3516 · e-mail:joseph@fischetti.com
Date:
Reference:
August 4, 2007
1040 Founders Path
Mike Verity, Building Inspector
Southold Building Dept
PO Box 1179
Southold, NY 11971
Dear Mr. Verity,
I have inspected the existing sanitary system for Ms. Susan Smith at the above
referenced home. I certify that the system consists of a 1000 gallon septic tank and 8 foot
diameter leaching rings with 12 feet of leaching and that the system was in operating order
when inspected. The system is adequate for a 4 bedroom home in accordance with Suffolk
County standards.
~ Jo~ph Fischetti, P.E.
MAR - 4 2O09
BLDG. DEPT,
TOWN OF $OUTHOI. D
PROFESSIONAL ENGINEER
1725 HOBART ROAD/PO Box 616 SOUTHOLD, NEWYORK 11971
TEL: 631.765.2954 · FAX: 631.614.3516 · e-mail: joseph~fischetfi.com
Building Inspector
Southold Building Department
Main Road
Southold, NY 11971
Date:
Reference:
9/26/11
Justin & Susan Smith BP# 35017
Dear Sir,
I have inspected the construction on 1040 Founders Path during the construction of the 2
floor. The following inspections were done and found in compliance with New York State
Building Codes:
2.
3.
4.
5.
Framing Inspection
High Wind Strapping
Fire Caulking
Insulation
Plumbing with pressure testing
I certify that the newly constructed 2"d floor complies with New York State Codes.
Permit if
Permit Dote
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: New 2nd Floor Addition
Report Date: 04/18/07
Data fllename: Untided.rck
Energy Code:
Location:
Construction Type:
Heating Type: Non-Electric
Glazing Area Percentage: 11%
Heating Degree Days: 5750
Construction Site:
Founders Path
Southold, NY 11971
New York State Energy Conservation
Construction Code
Suffolk County, New York
Detached I or 2 Family
Owner/Agent:
Justin Smith
DesignedContractor:
Joseph Fischetti
Professional Engineer
1725 Hobart Road
Southold, NY 11971
631-765-2954
Ceiling 1: Flat Ceiting er Scissor Truss: 731 30.0 0.0 26
Ceiling 2: Cathedral Ceiling (no attic): 700 30.0 0.0 24
Wall 1: Wood Frame, 16" o.c.: 1280 19.0 0.0 69
iodow 1: Wood Frame:Double Pane: 135 0.350 47
T~i~[ 'epresented in this document is consistent with the building plans, specifications, and other calculations
subn~ tion. The proposed systems have been designed to meet the New York State Energy Conservation
Co~ When a Registered Design Professiooa[ has stamped and signed this page, they are attesting that
~th this perm'~p~ication. The
off, ode requiremerlt~When a I._ ent, such
Build ;signer ~ ,~, ny Name
~signer ~A~ ~,~ ~'~,'
plans or specifications are in compliance w~ this (~ode.
Date
New 2nd Floor Addition Pa~e 1 (~ 1
LOT NUMBERS REFER TO "FOUNDERS ESTATES" F/LED
IN THE SUFFOLK COUNTY CLERK'S OFF/CE ON MA Y 10,
AS FILE NO. 8J4.
1927
THE LOCATION OF SEPTIC SYSTEM SHOWN HERON ARE
FROM F/ELD OBSERVATIONS AND / OR DATA OBTAINED
FROM OTHERS.
N
SURVEY OF PROPERTY
A T SOUTHOLD
TOWN OF SOUTHOLD
SUFFOLK COUNTY, N.Y.
1000-64-02-15
SCALE' 1'--$0'
MA Y 21, 2007
AREA=22,111 SO. FT.
· =MONUMENT
ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOl-AT/ON
OF SECTION 72090F THE NEI¢ YORK STATE EDUCATION LAI~.
EXCEPT AS PER SE¢iTON 7209-SUBDIVISION 2. ALL CERTIFICATIONS
HEREON ARE VAI. ID fOR THIS MAP AND COPIES THEREOF ON& Y IF
SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR
WHOSE SIGNA lURE APP£ARS HEREON.
I ~ - ~," I ~) I
I
I I
I e, co~ ~,~ I,'
I
~/ ~ - ~ /~ ~ / ' :~ ,
,' Venire Fire Pro[et[ion Macari Vineyard
~ S~IN~ Hm. w/l~e~EOa~ OU~O 1221 Suffolk Ave North Road
~ ~OW ~TCH ~ ~' 21Z RmAB~ MOD~ FI~ B~ UPRIGm SPRINK~ Hm. j Brentwood NY 11717 Mattituck, NY
~ D ~c. A~M BE~ ~P. RINK~ .m. F~F. 631 231 5173
"~ ~0
REAR ELEVATION FRONT ELEVATION
SCALE: i/4" = 1~-0'' SCALE: 1/4" = 1'-0"
D~WN BY: 3F/MH
_ _
LE~ ELEVATION RIGHT ELEVATION ]une 05, 2011
S~LE: 1/4" 1'-0" S~LE: 1/4"= 1'-0"
= S~LE: NTS
SHEET NO:
3' HIGH RAILING
~," SUBFLOOR
9-1/2 TJJ23O WOOD-I FJ @16"O~C
{2) 1-3/4Xl1-7/§ ML w/
1/2" STEEL FLITCH PLATE
EXIS~NG
EXISTING
SECTION A-A
SCALE: 1/4" = 1'-0"
"J I:
': /
WIND-BORNE DEBRIS PROTECi ION FOR WOOD STRUCTURAL PANEL
AS PER TABLE 1609,1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING)
/
/
/
/
/
/
/
/
24'-O"
2ND. FLOOR PLAN
SCALE: 1/4" = 1'-0"
/ ,,,,,,,,"
ROOF P~N
REPLACE EX DOOR
(2) 1-3/4Xll 7/B ML HDR
24'-0"
iST. FLOOR PLAN
SCALE: 1/4" = 1'-0"
~%7~
~o ~z~
'~' Z
DRAWN BY: ]F/MH
June 05, 2011
SCALE: NTS
SHEET NO:
WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS
USE THE FOLLOUJING APPRO'v'ED USP METAL C. ONNEC, TOR,5 FOR PROPER IUIND RESISTANT ~ GOOD CONSTRUCTION. FOLLOIU MANUFACTURE'~ RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY.
RAFTER -- ~ )~ ~ WALL STUD
I HEADER DOUBLE JOIST Z
0
FLOOR USP NUMBERI 3ESCRIPTION APPLICATION /
1 ST. ADS5 I HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS ~
ANCHOR TO FOUNDATION W/ANCHOR BOLTS BATH / SPA TUBS TO HAVE A DOUBLE FLOOR ~OISTS UNDER FOR ADDED SUPPORT L~J
i CONNECT TO 1 SiDE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION .OCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION ~ APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITR THE FLOOR
HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP ~OIST DIRECTION WITH (2) ~OISTS. UNDER WALL.
i 2ND. ADS5 ANCHOR PLATES OF 1 ST. FLOOR. CONNECT THROUGH ALL OPENINGS LSTA12 1-1/4"xl 2" 20ga. STRAF APPLY TO EACH JACK STUD ROOF LSTA24 1-1/4"x24" 20ga. STRAF APPLY OVER RIDGE TO EACH RAFTER 2x6-2x8 LS26 18ga. SLOPE HANGERi ~PPLY TO EACH RAFTER:/LEDGER
i FOR ;TOIST NOT DIRECTLY UNDER PARALLEL WALLS. PROVIDE
I FHE FLOORS TO EACH OTHER W/THREADED ROD. ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUN 2X10 LS210 18ga, SLOPE HANGER ~PPLY TO EACH RAFTER:/LEDGER SLOCKING ~24"0C
VENTS SELECTED AND
~ CATED BY CONTRACTOR ~ O
METAL STRAP ~ · ~' I CRICKET AT TOP-SIDE OF '" VENTILATION CHANNEL i Z ~J~ O
RIM BOARD O /CHIMNEY AS REGUIRED 0
SILL PLATE(S) () WALL SHEATHING
...... ' ' FINISH WALL AND MOISTURE ~ ~ 2x4 LEDGER BLOCKING
STAPPING TO SE ATTACHED TO WALL STUDS ~4g"OC BARRIER TO LAP FLASHING ATTIC SHALL BE PROVIDED WITH A ~ ~/ ~ ~ ~ FASCIA
AND ALL WINSOW/DOOR OPENING JACK STUDS ~ / / AT WALL -- MAINTAIN GAP MINIMUM NET FREE VENTILATING AREA -
FLOORJOISTDEPTHUSP.UMBSR DESCRIPTION ^PP.DATION ' /BETWEENWALLFINISHANS --Gu'r'rE.
~, THE SPACE VENTILATED ALL OPENINGS ~ ,_
INSTALL 4'0" D.C. " VE ED W ~ CORROS ON- i [CONTZ~OkcONTIN' SCREENED VENT
4" - 8" LSTA24 1-1/4"x24" 20ga. STRAF AND JACK STUDS ~, SHALL BE CO R I H I
FFIT / EXT. PLYWOODRESiSTANT METAL MESH WI'TR
ON ALL OPENINGS ~ ~ / /~.., / PROVIDE HEMMED EDGE AT ~ MESH
,,STALL4'0" D.C. ' ANDFLAS"INGT0 FD,MCHANNELsD ASTO, NAINTAI, AI, LOCATION USPN'.'MSER DESORIPT,ON ^PPL,OAT,ONoo,NEDT TO OPENINGSOE .INC, DI 'E,S,ON. S, OF= TE RAVE
8" - ~4" LSTA30 1-1/4"x30" 1Sga. STRAF AND JACK STUDS '~/~,. ~/ ~' - , .~, '~-~'~"-~- GAP TO FREVIENT CAPILLARY 4" - 6" RAFTER RTl 0 10-3/4" x 18ga. TYDOWN ANCHOR EACH RAFTER
3N ALL OPENINGS PROVIDE BLOCKING BETWEEN ~OISTS THAT ARE SPICED AND
14" - 16" LSTA36 1-1/4"x36" 18ga, STRAP AND JACK STUDS~ ~' ~'~ :8" - 12" RAFTER RT20 21-1/8" x 20ga. TYDOWN ANCHOR CONNECT TO
ON ALL OPENING~ ~ > KEEP ROOFIh~G NAILS OUT
RAFTER
~ SAGE FLASHING WRAP~S CORNERS, RIDGE CAP OF SJAME
INCHEG AND ~APS NAILED TO SHEATHING
SHINGLES AT BASE MILK. 4 INCHES THROUGH VENT
' I i TOP PLATE GIRDER/HEADER
I - 511::>E WALL FLASNIN
WOOD JOIST
1ST. FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS
AND ALL WINDOW/DOOR OPENING ~TACK STUDS METAL FLASHING AT ALL EAVES, 51DELUALLG, WALL STUD
FLOOR JOIST DEPT~ USP NUMBER DESCRIPTION APPLICATION AND i~A~E~ -- PROVIDE HEP1MED EDGE5 GO
4" - 8" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS pRE'./ENT CAPILLAf~¥ ACTION LOCATION USP NUMBER DESCRIPTION ~ APPLICATION PRE-MANUFACTURED KEEP SHEATHING MIN. i-i/2" ALL ~OISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WTrH ~ r~
DN ALL OPENING~ , CONNECT EACH RIDGE VENT FOLDS FSOM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR.
INSTALL 4'0" D.C. ~AFTER/pLATE RTl 5 TYDOWN ANCHOR RAFTER TO PLATE OVER RIDGE TO AIS PASSAGE IF ABLE, SET FIR ~OISTS APROX. 1/2" HIGHER THAN LVL READERS-~, UJ
s" - 16" MSTA48 1-1/4"x48" 16ga, STRAP AND JACK STUDS I ' CONNECT OVER CONFORM TO SLOPE TO ALLOW FOB SHRINKAGE. ~ REDUCE BUMP OUTS ~ UJ
I DN ALL OPENING~ PLATE/WALL SPTH4 STUD PLATE ANCHOR :~LATES TO EACH STUN OF ROOF Z
DBL. SILL PLATE 'i) BUR)FLOOR
SILL GASKET ; [UOOD JOIST5 I X L~
RODE ',, r,J) n' O co
,~ ~ / I / COMPACT FILL ~ > t ROOFING LAPS TOP AND [BOTTOM PLATE
KEY~VAYFOOTING > A CONC. FTG. ~ '~, s. '~, (USPLBPS58ORBP583) ~ (~ r~
% ~' ANCHOR BOLT CONNECTION USEWITH3x3SQUAREWASHERS SIDES AND TOP I/2" GROUT
FOUNDATION 5tS"DIA. ANCHORSOLT , I I I '" ~" STEEL COLUHN
SILL pLATE TO FOUNDATION ROOFING AT B TTOM
(CRAWL SPACE OR FOUNDATION} I STORY 72" DC TYPICAL E~EAM DETAIL
SILL PLATE TO FOUNDATION
TYPIEAL CONE. FOUNDATION. APPLY PILASTESS MIN. B" STEEL COLUMN ANCHORED TO 24"x24"x12" CONE. FTC. (CRAWL SPACE OR FOUNDATION) 2 STORIES 36" DC STEEL / ESOTTOM ESEARING
WHERE NEEDED FOR STRUCTURAL BRACING. WALL BO'r'rOM plATE TO FOUNDATION -
(SLAB-ON-GRADE) 1-2STORIES s7"oc ROOF JACk5 ~ YENT5 DETAIL
ii//// DOOR FRAME
SXSI0/'mWWM //// USE XS i DRAWN BY: ]F/NH
COMPACT FILL
4" ~ A , r/// FORBLOCKOUT~ STEEL BEAM
' o , ¢ ..; STEELSEA. TOALLOWFOSSSRIN GE SCALE: NTS
r '[ 4 ~REINFORCINGBAR s . ~ ~, ~ REINFORCING BAR ~,~
12" OF CONTACT W~H CONCRETE OR CONE. BLOCK
R~FORCE FOOTING W~H (2) '4 REINFORCING BARS. 3" MINIMUM BEARING SURFACE FOR WOOD BEAM ~ARAGE DOO~
~EAM ~OCKET
<~. KING STUDS ' ~ RAFTER ~ ~ WALL STUD ' ~::~
HEADER DOUBLE JOIST
SIDEWALL RAFTER
FLOOR USP NUMBEF ~ESCRIPTION APPLICATION
HOLD DOWN CONNECT TO 1 BIDE OF ALL CORNERS
1 ST. ADS5 ANCHOR TO FOUNDATION W/ANCHOR BOLTS BATH / SPA TUBS TO HAVE A DOUBLE FLOOR ~OISTS UNDER FOR ADDED SUPPORT
CONNECT TO 1 S~DE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION .OCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR
HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP ~OIST DIRECTION WITH (2) ~OISTS. UNDER WALL.
2ND. ADS5 ANCHOR P~TES OF 1 ST. FLOOR. CONNECT THROUGH ALL OPENINGS LSTA12 1-1/4"xl 2" 20ga. ST~F APPLY TO EACH JACK STUD ROOF LSTA24 1-1/4"x24" 20ga. STRAF APPLY OVER RIDGE TO EACH RAFTER 2x6-2x8 LS26 18ga. SLOPE HANGER;i ~PPLY TO EACH ~FTER:/LEDGER
FOR ~OIST NOT DIRECTLY UNDER PARALLEL WALLS. PROVIDE
THE FLOORS TO EACH OTHER W/THR~DED ROD. ALL OPENINGS RT3 OR R~ ~DOWN ANCHOR APPLY TO EACH CRIPPLE STUN 2X10 LS210 18ga, SLOPE HANGER' ~PPLY TO EACH RAFTER:/LEDGER BLOC~NG ~24"0C
VENTS SELECTED AND
~ CATED BY CONTRACTOR
METAL ST~P ~ mCRICKET AT TOP-SIDE OF ~ V/NTI~TION CHANNEL
SILL P~TE(S) (~ WALL SHEATHING R~FTE~
STAPPING TO BE ATTACHED TO WALL STUDS ~4~"OC BARRIER TO ~P F~SHING ATTIC SHALL BE PROVIDED WITH A ~ ~/ ~ ~ ~ FASCIA
AND ALL WINDOW/DOOR OPENING ~ACK STUDS ~ / ~ AT WALL -- M~NT~N GAP MINIMUM NET FREE VENTI~TING AREA -
~, THE SPACE VENTI~TED ALL OPENINGS ~ ,_
INSTALL 4'0" D.C. ' VE ED W ~ CORROS ON- CONTIN. SCREENED VENT
4" - 8" LSTA24 ¥1/4"~4" 20ga. ST~F AND JACK STUDS ~ -
FF~ / EXT. PLYWOODRES[STANT HETAL HESH
DN ALL OPENINGS ~ ~ ~ ~ / PRO,DE HE~MED EDGE AT , MESH
"STALL 4'0" OmC' ' ~ ~ /~ /~ ~N~FLASH'NG T0 FOR" ~H~NNELso AS T~ "~NT~N AIR LOCAT'ON U~P NUMBER DESCRIPTION APPLICATIONcoNNECTTO OPEN'ECS O~ ~' '"~" ~ D[~[NSIO"m ~OFF)Tm
B" - 14" LSTA3O 1-1/4"x30" 18ga. ST~F AND JACK STUDS ~ ~ ~/ ~' -~~ GAP TO PREVENT CAPILLARY 4" - 6" ~FTER RTl 0 10-3/4" x 18ga. ~DOWN ANCHOR ~CH ~FTER
3N ALL OPENING~ PROVIDE BLOCKING BE~EEN ~OISTS THAT ARE SPICED AND
14" - 16" LSTA36 1-1/4"x36" 18ga, ST~P AND JACK STUDS~ ~~~ :8" - 12" ~FTER R~0 21-1/8" x 20ga. ~DOWN ANCHOR CONNECT TO
~CH ~ER ~OFFITED EASE DETAIL
~FTER
~ BASE FLASHING WRAP~ CORNERS, RIDGE CAP OF SJAME
SH~GLES AT BASE HI~. 4 INCHES THROUGH VENT
'm m TOP P~TE GIRDER/HEADER
- IDE WALL FLASHING
WOOD JOIST
1ST. FLOOR WALL STAPPZNG TO BE ATTACHED TO WALL STUDS
AND ALL WINDOW/DOOR OPENING ~ACK STUDS M~AL FLASHING AT ALL EA~ES, SIDEWALLS, WALL STUD
4" - 8" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS P~T CAPI~A~T ACTION LOCATION USP NUMBER DESCRIPTION APPLICATION PRE-MANUFACTURED KEEP SHEATHING MIN. 1-1/2" ALL ~OISTS CONNECTED TO A FLUSH H~D[R TO BE SUPPORTED W~H
3N ALL OPENING~ CONNECT EACH RIDGE VENT FOLDS FROH P~K TO ALLOW FREE THE PROPER STEEL CONNECTOR.
INSTALL 4'0" D.C. ~AFTE~P~TE RTl 5 ~DOWN ANCHOR RAFTER TO PLATE OVER RIDGE TO ~R P~SAGE [F ABLE, SET FZR ~OZSTS APROX. ~/2" HIGHER THAN LVL H~DERS
8" - 16" MSTA48 1-1/4"x48" 16ga, ST~P AND JACK STUDS CONNECT OVER CONFORH TO SLOPE TO ALLOW FOR SHRINKAGE. ~ REDUCE BUHP OUTS
3N ALL OPENING~ PLATE/WALL SPTH4 STUD P~TE ANCHOR ~TES TO EACH STUN OF ROOF
TERMITE SHIELD , +
~ ~ "~ F~SHING AT ~ITH I/2" x ~" ANCHOR ~OLT
% ~ ANCHOR BOLT CONNECTION us~ WITH 3x3 SQUARE WASHERS I/2" GROUT
(C~WL SPACE OR FOUNDATION) I STORY 72" DC TYPICal ~E~M DETAIL
TYPI~L CONE. FOUNDATION. APPLY PIASTERS MIN. 3" STEEL COLUMN ~CHORED TO 2~"x24"x12" CONE. FTC. (C~WL SPACE OR FOUNDATION) 2 STORIES 36" DC STEEL / ~OTTOM BEAR
WHERE NEEDED FOR STRUCTURAL BRACING. W~L BOSOM P~TE TO FOUNDATION
(S~B-ON-G~DE) 1-2STORIES 57"OC ~OOF JACKS 4 V~T5 DETAIL
6x610/10 ~M DOO~ //// USE 2XB i
........ (PROVIDE STRAPPING TO KEEP JOISTS ALIGNED)
?~ '[ 4 ~REINFORCINGBAR~ . ~ ~, ~ REINFORCING BAR ;,,
~ SHEET HETAL / 30~ FELT UNDER B~M AT PO~T ~ STEEL B~AM
(BOLTED
R~FORCE FOOTING ~H (2) '4 REINFORCING BARS. 3" MINIMUM ~EANIN~ SURFACE FOR WOOD BEAM GARAGE DOO~
~EA~ POCKET
GENEf ,L NOTE,
CONSTRUCTION NOTES:
· The information within this set of construction documents is related to basic design
details. They are intended as a construction aid, not a substitute
for generally accepted good building practice and compliance with current New York
State building codes. The General Contractor is responsible for providing standard
:onstruction details and procedures to ensure a professionally finished, structurally
sound and a weatherproof completed product.
2). The General Contractor is responsible for ensuring that all work and construction
'neats current federal, state, county and local codes, ordinances and regulations, etc.
these codes ara to be considerad as pad of the specifications for this building and
should be adherad to even if in variance with the plan.
3). Dimensions shall take precedent over scaled drawings.
(DO NOT SCALE DRAWINGS).
4). The designer has not been engaged for construction supervision and assumes no
responsibility for construction coordinating with these plans, nor responsibility for
construction means, methods, techniques, sequences, or procedures, or for safety
precautions and programs in connection with the work. There are no warranties for a
specific use expressed or implied in the use of these plans.
5)· Refer to the Window and Door schedule for exterior openings.
6). The General Contractor is to ensure that masonry or prefabracted fireplaces meets
or exceeds manufactura's specifications and applicable codes.
7). The General Contractor is to consult with the owner for all built~in items
such as bookcases, shelving, pantry, closets, trims, etc.
I. Wind load requirements shall be taken into account during construction.
FOUNDATION NOTES:
1). The General Contractor and Mason to review plans, elevations, details and notes to
determine intended heights of finished floor(s) above typical grade.
· All footings to rest on undisturbed (virgin) soil. (MiN. SOIL STRENGTH AT 2000psi)
· Provide 1/2" expansion joint matedal between concrete slabs and abutting
walls occuring in exterior or unheated intedor areas.
~). Any new concrete walls being attached to existing concrete structure shall
be installed wfih ~- re-bar, 18" long at 12" o.c.. Use approved epoxy for installation.
5)· Unless otherwise noted, all slabs on grade to be 3500 p.s.i.. Concrete to be
nch thick sand or gravel fill with 6x6 wire mesh reinfoming, thtedor slabs
Ich thick. All fill to be compacted to 95% relative density with
6" maximum lifts (layers).
6). Crawl spaces to be provided with a minimum 18"x24" access opening. Instsll one
8x16 cast iron foundation vent for every 150 sq. ff. of area.
7). Damppraot extedor of foundation with bituminous coating as per
N,Y.S· Residential Construction Code. A 6-mil polyethylene film shall be applied over
the below grade portion of extedor walls prior to backfilling.
8). Drainage as per town and N.Y,S. Residential Construction Code·
FRAMING NOTES
1)· All framing techniques and methods as prescriptive design of current SBC High W nd
Edition Wood Framing Construction Manual.
2). Unless otherwise noted, a fram ng and structural wood material to be #2 + BTR.
Douglas Fir.
3). Floors, walls, ceilings and ratters to be spaced at 16 inches o·c. unless noted
otherw se.
· Unless otherwise noted, all beadng wail headers to be (2) 2x10 #2 + BTR. Doug. Fir.
headers to have (2) jack studs and (2) full length studs on each side of all
~peeings. LVL headers to have (3) jack studs and (2) full length studs on each side of
~penings. Beadng wall window siJls shall also have (2) window sill plates for 2x4 wall
~penings between 4'1 and 6'0 and 2x6 wall openings between 5'11 and 8'9. Provide fire
and blocking where applicable.
5). All flush beams/headers to be installed with heavy duty galvinized hangers and
anchors where applicable to all connecting joists.
6)· Double up floor joists under walls that run parallel to the floor joist and under bathtubs
Floors to have ceramic tile installed shall be verified for proper load capacity unless note,
on plans.
7). Provide blocking/bridging in floor joists at 8'0 o.c.. Use solid blocking in floor joists
under all bearing walls.
8). Provide insulation baffles at eave vents between rafters. Install draft blocking as
needed.
9). Unless otherwise noted, all roofs and walls to have a minimum 1/2" thick 4-ply Fir
CDX exter or sheath ng grade plywood. Plywood to cover over plates and headers.
10). Unless otherwise noted use 3/4" thick T&G PTS Fir or Advantech plywood subfioor
adhered with PL400 adhesive and screwed to floor joists. Finished floor to be installed
over subfioor as per manufacture's instructions.
11 '
), All bathroom walls to have 1/2 th ck mo sture-ras stunt sheetrock. Garage wa s and
~eilings and over furnace to have 5/8" thick type-x sheetrock. All other parts of building
Io have regular 1/2" sheetrock. All walls to be taped and finished.
All roof with a pitch less than 4:12 shall be installed with an Ice & Water barrier or
pplied with a Fiberglas base sheet with an EPDM
fetch down type material over.
13). All sill plates and wood in contact with concrete to be pressure treated. Sill plates to
3e installed with a foam sill gasket and cop-r-tsx termite shield or approved equal.
WIND FRAMING NOTES
1). RIDGE-TO-RAFTER ASSEMBLY:
1-1/4" x 20 gauge strap shall be attached to each pair of ratters in accordance to table 3.4.
When a collar tie is used in leu of a ridge strap, the number of 1 Od common nails required
in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap.
2). RAFTER-TO-WALL ASSEMBLY:
Lateral framing and shear wall connections for rafter, ceiling or tlruss to top plate shall be in
accordance to table 3.3. When a rafter or truss do not fall in line with studs below, rafters
or trusses shall be attached to the wall top plate and the wall top plate shall be attached to
the to the wall stud with uplift connections. Roofs overhanging the rake side of the building
shall be connected with uplift connections in accordance with table 3.3c.
3)· WALL-TO-WALL ASSEMBLY:
Wall studs above and studs below a floor level shall be attached with uplift connections in
accordance with table 3.3b. When wall studs above do not fall in line with studs below, the
studs shall be attached to a common member in the floor assembly with uplift connectors in
accordance with table 3.3.
4). WALL ASSEMBLY TO FOUNDATION:
First wall studs shall be connected to the foundation, sill plate, or bottom plate with up[Jif
connectors. Steel straps shall have a minimum embedment of 7 inches in concrete
[oundatlco and slab-on-cjrade, 15 inches in masonry block foundations, or lapped under
the plate and nailed in accordance with table 3.3b. When steel straps are lapped under the
bottom plate, 3 inch square washes shall be used with the anchor bolts. Anchor bolt
spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing,
anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all
:omera.
5}. TYPE I EXTERIOR SHEARWALL CONNECTIONS:
type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior
attached with 8d common nails at 6" o.c. at the panel edges and 12" o.c. in the field, and
I/2 inch gypsum wallboard on the intedor attached with 5d cooler nails at 7" o.c. at panel
edges and 10" o·c. in the field shall be in accordance with the len~gth requirements specified
in table 3·15a-b.
6). TYPE II EXTERIOR SHEARWALL CONNECTIONS:
Type II exterior shearwalls shall meet the requirements of table 3.15a-b times the appropriate
length adjustment factors in table 3.16·
7). INTERIOR SHEARWALL CONNECTIONS:
Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when
interior shearwalls are used. Sheathing and connections shall be in accordance with
2.4.4,2 and 2.2.4 respectively.
8), CONNECTIONS AROUND EXTERIOR WALL OPENINGS:
Header and/or girder connections shall be attached with uplffl comnections in accordance
with table 3.5. Window sill plates shall be have steel connectors in accordance with table
3.5.
g). CATHEDRAL CEILING ASSEMBLY:
Where a ridge is to be used as a structural beam, the ratters shall either be notched and
anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge
along the open ceiling part of the building. Connections to the ddgle and wall shall be be
attached with the above requirements.
DECK AND COVERED PORCH NOTES:
1). Unless otherwise noted, a~l framing matsdal to be #1 ACQ pressure treated umber.
A I fasteners, hangers and anchors to be galvinized or stainless st~eeL
2). Girders for deck joists to be bolted to each post with washers amd nuts.
Gitders on concrete piers sha be anchorad wfih proper stsel con~nectors anchored
into concrete with a minimum 1/2" dia x 7" long anchor bolt with washers and nuts.
3). Posts supporting girders shall be anchored to a 12"x12"x12" thlick concrete footing.
Use a minimum 1/2" dia x 7" long anchor bolt with washers and nuJts. Footings Shall be 3 ft.
below grade. Porches with covered roots shall have 12" dia. concrete piers for the girders.
4)~ Deck joists to have blocking at 8'0 o.c..
5). A minimum of 10 inch flashing shall be installed between the bluilding and ledger.
Ledger to be fastened to building with 1/2" dia, bolts with washers and nuts
where needed.
~. Concrete piers shall be a minimum 6" above grade.
supported with hangers and anchors. Each Joislt shall also be anchorad
to gkder(s).
· Covered Roofs shall be assembled and anchorad the same manner as a typical building.
PLUMBING NOTES
1). All water supply, drainage and venting to be installed as per N.Y·S. Residential
Construction Code.
2). Verify septic system with the Engineer for Suffolk County Health Department approval.
3). If wail studs, plates or joists ara cut out during installation for any plumbing related work,
3mvide adequate bracing and plates to protect and secure the structure. Verity with the
state code and manufacture's recommendation for maximum hole size and spacing permitted
HVAC SYSTEM NOTES
1}~ Mechanical subcontractor is reaponsible for adhearing to all applicable codes and safety
raquirements.
2). HVAC subcontractor is to fully coordinate all system data and requirements with the
equipment supplier.
3). HVAC subcontractor to provide final system layout drawing and submit it to the General
Contractor and owner for final review and approval.
ELECTRICAL NOTES:
~. All electrical to be installed as per N.Y.S. Residential Construction Code.
,. All electrical work shall be approved by a qualified Underwrfier.
· Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317
f N.Y.S. Residential Construction Code,
NAILING SCHEDULE .............
ROOF FRAMING: , PL, N CONTENT6:
JOINT DESCRIPTION NAIL NAIL
QTY· SPACING NOTES
RAFTER TO 8' WALL: 3-8d COMMON EACH
TOP PLATE tO' WALL: 4-8d COMMO~ RAFTER TOE-NAIL
CEILING JOIST 8' WALL: 3-8d COMMON EACH
TO TOP PLATE 10' WALL: 4-8d COMMON JOIST TOE-NAIL
CEILING JOIST TO AS PER TABLE 3.7 EACH FACE
PARALLEL RAFTER WFCM - SBC LAP NAIL
CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE
OVER PARTITION WFCM - SBC LAP NAIL
COLLAR TIE AS PER TABLE 3.4 EACH FACE
TO RAFTER WFCM - SBC END NAIL
BLOCKING EACH TOE
TO RAFTER 2 - 8d COMMON END NAIL
RIM BOARD EACH END
TO RAFTER 2 - 16d COMMON END NAIL
WALL FRAMING:
JOINT DESCRIPTION NAIL NAIL
QTY. SPACING NOTES
TOP PLATE TO PER FACE NAIL
TOP PLATE 2 - 16d COMMON FOOT SEE NOTE: 1
TOP PLATES AT JOINTS FACE
INTERSECTIONS 4 - 16d COMMON EA. SIDE NAIL
STUD TO 24" FACE
STUD 2 - 16d COMMON O.C. NAIL
HEADER TO 16" O.C. FACE
HEADER 16d COMMON ~,LONG EDGES NAIL
TOP OR Be'Fi-OM 2 - 16d COMMON PER 2x4 STUD END
PLATE TO STUD 3 - 16d COMMOh PER 2x6 STUD NAIL
BOTTOM PLATE TO:
=Leer JOIST, BAND JOIST 2 - 16d COMMON PER FACE NAIL
END JOIST OR BLOCKING FOOT SEE NOTE: 1,2
FLOOR FRAMING:
JOINT DESCRIPTION NAIL NAIL
QTY. SPACIN( NOTES
JOIST TO: PER TOE
SILL, TOP PLATE OR GIRDER 4- 8d COMMON JOIST NAIL
BRIDGING EACH TOE
TO JOIST 2 - 8d COMMON END NAiL
BLOCKING EACH TOE
TO JOIST 2 - 8d COMMON END NAIL
BLOCKING TO:
SILL OR TOP PLATE 3- 16d COMMON EACH TOE
BLOCK NAIL
LEDGER STRIP
TO BEAM 3- 16d COMMON EACH FACE
JOIST NAIL
JOIST ON LEDGER PER TOE
TO BEAM 3~ 8dCOMMON JOIST NAIL
BAND JOIST PER END
TO JOIST - 16d COMMON JOIST NAIL
PER TOE NAIL
BAND JOISTTO; 2- 16d COMMON FOOT SEE NOTE:
SILL OR TOP PLATE
ROOF SHEATHING:
JO,,TDESCR,PT,ON SP"2C', G
tSTRUOTURALPANELI fidI
CEILING SHEATHING:
NAiL NAIL
JOINT DESCRIPTION QTY. SPACING
GYPSUM I~,~ r','~c~mel 7" O.C. EDGE
WALLBOARD I ......... I10" O.C· FIELD
WALL SHEATHING.
·
NAIL
JOINT DESCF IPTION QTY. I
STRUCTU ),AL ..... AS
PANEL~; 8d Cu~ur~
7/16" O~ 3 ~
PLYWO£ D §d CO,,,MON
GYPSUI t 7
WALLBO,~ ;iD 5d COOLERS 11
FLOOR SHEATHING:
JOINT DESCRIPTION NAIL NAIL
QTY. SPACING
STRUCTURAL
PANELS 8d COMMON AS PER TABLE 3.9
WFCM - SBC
7/16" OSB 3" O.C. EDGE
PLYWOOD §d COMMON 6" O.C. FIELD
GYPSUM 7" O.C. EDGE
WALLBOARD 5d COOLERS 10" O.C. FIELD
NAIL NAIL
JOINT DESCRIPTION QTY. ,,SPACING
STRUCTURAL PANELS r, 60.C. EDGE
1 OR LESS 8d COMM,~N 12" O.C. FIELD
NOTES:
THESE NOTES ARE ONLY TO BE REFERRED TO IF
MENTIONED iN SCHEDULE NOTES ONLY.
1}. Nailing raquirements are based on wall sheathing
nailed 6" on-center at the panel edge. if wall sheathing
is nailed 3" on-cecter at the panel edge to obtain higher
shear capacities, nailing requirements for structural
members shall be doubled, or alternate connectors,
such as shear plates, shall be used to maintain load path.
2). When wall sheathing is continuous over connected
members,the tabulated number of nails shall be permitted
to be reduced to1 - 16d nail per foot.
OCC[JpANC¥ CLASSIFICATION f~3 I~E~IDENTIAL
~UILDING 11SE I ~SIDEN~L DWEL~NG
~UILDING HEIGHT
TRU65 DE61GN N/A - 6TANDARD 5TICK ~AHE CONSTRUCTION
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA
GROUND WIND SEISMIC FROST WINTER ICESHIELD
SNOW SPEED DESIGN INEATHERIN(~ LINE TERMITE DECAY DESIGN UNDERLAYMEN3 FLOOD
LOAD (MPR) CATEGORY DEPTI- TEMP. REQUIRED HAZARDS
20LBS. 1t0 B SEVERE 3FT. MODERATE SLIGHTTO
TO HEAVY MODERATE 11 NONE
ROOF SHEATHING REQUIREMENTS FOR WIND LOADS:
SHEATHING LOCATION ,NAIL SPACING NAIL SPACING AT INTERMEDIATE
A'T PANEL EDGES SUPPORTS iN THE PANEL FIELD NOTES
4' PERIMETER EDGE ZONE 5d COMMON @ 6" O.C. 8d COMMON @ 6" O.C. SEE NOTES: 1,3
INTERIOR ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. SEE NOTES: 1 ( BOTH FIELDS
NOTE: 2 FOR PANEL FIELD
GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4" O.C. 8d COMMON @ 4" O.C. SEE NOTES: 1,3
NOTES
THESE NOTES ARE ONLY TO BE REFERRED TO) IF MENTIONED IN SCHEDULE NOTES ONLY·
1 ). For roof sheathing within 4 feet of the perimeter ~edge of the roof, including 4 feet on each side of the roof peak,
the 4 foot perimeter edge zone attachments required shall be used.
2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to rafter / truss framing members with G>0,49.
For framing members with <0.42<G<0.49, the nail spacing shall be reduced te 6 inches o·c.
3)· Tabulated 4 inch o.c. nail spacing assumes sheathing to rafter / truss fram ng members with G>0.49. For
framing members with 0.42<G<0.49, the nail spacing shall be reduced to 3 inches o.c.
WALL SHEATHING REQUIREMENTS FOR WIND LOADS:
SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATI
AT PANEL EDGES SUPPORTS IN THE PANEL FIELD NOTES
4' EDGE ZONE ~d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. SEE NOTES: 1, 3 ( BOTH FIELDS
NOTE: 2 FOR PANEL FIELD
INTERIOR ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C, SEE NOTE: 3
NOTE S
THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
1). For wall sheathing within 4 feet of the corners, [the 4 foot edge zone attachment requirements shall
be used.
2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to stud framing members with
G>0,4§. For framing members with 0.42<G<, the r~ail spacings shall be reduced to 6 inches o.c.
3). For exterior panel siding, galvinized box nails shall be permitted to be substituted for common naJls~
NOTE:
CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY
EXISTING CONDITIONS. MINIM!UM 3000# CAPACITY,
1)~ PROVIDE 5/8" TYPE-X SHEETROCK FIRE S~TOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS.
2). USE SIMPSON HANGERS AND ANCHORS tWITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT W~TH ACQ.
3). INSTALL 1 - Co2 DETECTOR IN ADDITION 'lro SMOKE ALARMS PER FLOOR.
F[REBLOCI~NG REQUIRED
Fireblocldng shall be provided to cut off a~l conceale~l draft openings (both vertical and horizontal)
and to form an effeddve fire border between stories, and between a top story and the roof space·
Fireblocking shall be provided in wood-flame constrruction in the following locations.
1). In concealed spaces of stud wa~ls and partitions, including furred spaces, at the ceiling and floor
levels. Concealed horizontal furred spaces shall a~lso be fireblocked at intervals not exceeding 10
feet. Baits or blankets of mineral or glass fiber shla]l be allowed as flrebleckiag in wails constructed
using parallel rows of studs or staggered studs.
2). At alt interconnections between concealed vertical and horizontal spaces such as occur at soffits,
drop ceilings and cove ceilings.
3). In concealed spaces between stair stringers at tlhe top and bottom of the run. Enclosed spaces
under stairs shall comply with N.Y.S. Residential (Code.
4). At openings around vents, pipes and ducts at celiling and floor level, to resist the free passage of
flame and products of combusUon.
5). For the firablocking of chimneys and fireplaces, r~efer to N.Y.S. Residential Code.
Z
SCALE: NTS
SHEET NO:
r/
GENERAL CONSTRUCTION NOTES
1. The information on this set of construction documents is TO relate basic design
intent and framing details. They are intended as a construction aid, not a substitute
for generally accepted good building practice and compliance with current New York
state building codes. The general contractor is responsible for providing standard
construchon defatis and procedures to ensure a professionally finished, structurally
sound, and weatherproof completed product.
2. General Contractor to coordinate all sub contractors, scheduling of work, and
interaction between trades.
3. The general contractor is responsible for ensuring that all work and construction
meets or exceeds current federal, state, and local cedes, ordinances and regulations,
etc. These cedes are to be considered as part of the specifications for this building
and should be adhered to even if they are m variance with the plan,
4. Dimensions shall take precedent over scale drawings (do not scale drawings).
5. The designer has not been engaged for construction supervision and assumes no
respoos~bcity for construction ooordinafing wgh these plans, nor responsibility for
construction means, methods, techniques, sequences, or procedures, or for safety
precautions and programs Jn connecbon with the work. There are no warranties for a
specific use expressed or Implied in the use of these plans.
6. Refer to floor plans, exterior elevations, and window schedule for types and sizes of
windows. All windows to be Andersen high performance quality or approved equal.
7. Door and window headers to align un]ess otherwise noted.
8. General contractor is to ensure that masonry and prefabricated fireplace
construction meets or exceeds all manufacturer's specifications and applicable codes.
g. General contractor to consult and coordinate with the owner and the plans for ali
built in items such as bookcases, shelving, pantry, closets, etc.
10. Provide hardwired smoke detectors, with battery backup, on all tioom and in each
bedroom, verify with local code requirements as per Section R317, New York State
Remdenflal Construction Code. Install carbon monoxide detectors as per code.
GENERAL FOUNDATION NOTES
1. General contractor to review plans, elevations, and details to determine intended
heights of finished floor(s) above typical grade.
2. All footings to rest on undisturbed soil.
3. Provide ½" expansion joint material between all concrete slabs and abutting
concrete or masonry walls occurring m extedor or unheated interior areas.
4. Concrete on 4" sand or gravel fill minimum, with §x§ - 10! 10 wire mesh reinforcing.
Interior slabs to be placed on 6 mil. stabifized polyethylene vapor berder.
B. Provide crawl space ventilation per 1coot code requirements.
6. General contractor to install cop-r-rex (or copper) sheet metal termite shields
between all wood surfaces that are exposed to concrete or masonry surfaces.
7. Oampproof exterior of foundation with a bituminous coating as per code and so~l
conditions.
GENERAL FLOOR pLAN NOTES
1. Dimensions shall take precedent over scale drawings (do not scale drawings).
2. All interior walls to be covered with ½" gypsum board with metal corner relnfaming.
Tape, float, and sand (3 coats).
3. Wails common to garage and house to have a layer of 5/8", fire rated gypsum board
at garage side with 5'-0" return on adjacent walls and ceiling. Manufactured [umber
requires 2 layers of 5/8", fire rated gypsum board.
4. All bath and toilet area wails and ceilings adjacent to wet areas to have water
resistant gypsum board, or wall tile set on wonderboard or equal
DESIGN LOAD CALCULATIONS
MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS
EXTERIOR BALCONIES B0
BECKS 40
ATTICS WITHOUT STORAGE 30
ATTICS WITH STORAGE 40
ROOMS (OTHER THAN SLEEPING ROOMS) 40
SLEEPING ROOMS 30
3RITERIA FOR CALCULATION OF DEAD LOAD
ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A,I,A
ARCHITECTURAL GRAPHIC STANDARDS
I
SNOW
IGROUND SNOW LOAD 1451bs~
SEISMIC
IDESIGN CATEGORY IB
VIND
RY 1 2S mph
GENERAL FRAMING NOTES
1. All walls, 2x4 and 2x6, to be stud grade or better 16" o/c. All other framing material
to be #2 douglas fir or better.
2. All wood framing in contact with concrete or masonry to be pressure treated.
3. Prewde double floor joists under all waits parallel to floor jo~st span direction unless
otherwise specified.
4. Provide x-bracing or solid blocking at a maximum of 8'-D" o/c far all dimensional
lumber floor joists.
fi. Floor construction: %" tongue and groove plywood subfloor. Finished matedal to be
applied over subfloor. Glue and screw plywood decking to floor joists.
6. All w~ndow and door headers to be minimum (2) 2x10 unless otherwise specified.
All interior headers to be (2) 2x10 unless otherwise specified.
7. Prewde full solid blocking under all beadng walls.
8. All beams to have adequate bearing at each end or as specified.
g. All flush beam and joist intersections to have galvanized hangers.
10. Typical exterior walls and roof to be sheathed with ½" exteDor grade plywood or
7/16" OSB plywood, group 1, APA rated. Plywood to span over all plates and
headers.
11. ProviBe insulation baffles at Rave vents between rafters.
12. Exterior flashing to be correctly installed at all connections between reefs, walls,
chimneys, projections, and penetrations as required by approved construction
practices.
13. General contractor to provide adequate attic ventilation and roof vents.
APPROVED AS NOTED
NO~:IFY BUILDING' DEPARTMENT AT
765-1802 FIAM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNSATION - TWO REQUIRED
FOR FOURBD CONCRETE
2. ROUGH - FRAMING & PLUMBING
3. INSULATION
4. FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
SOUTHOLD TOWN ZSA
SOUTHOLO TOWN PLANNING SOARO
SOUTHOLD TOWN TRUSTEES
N,Y,S. DEC
14. Provide appropriate somt ventilation at overhangs, l,l,'~" .~ , ", 'r ," ' ,
1 Plumbing subcontractor ta be responsible for adhedng to all applicabta code and , BrCOMPL¥-WITH CHAPTER ~
,;', FLOOD DAMAGE PREV~ENTION
safety requirements, i ~' ,, ~OUTHOLD TOWN,CODE.
2. If wall plates orjoists are cut during the installabon of plumbing fixtures or '" ,, , ,, .-,,,,~>,,,,,'~ ~
equipment provide bracing to tie framing back together.
GENERAL HVAC SYSTEM NOTE S OCCUPANCY OR
1. Mechanical subcontractor is responsible for adhedng to all applicable codes and
safefyrequirements. USE IS UNLAWFUL
2. HVAC subcontractor TO fully coordthateailsysfamdtaa and requirements with the WITHOUT CERTIFICATE
equipment supplier. OF OCCUPANCY
3. HVAC subcontractor to provide final system layout drawing and submit it to general
ff~, ~n6 6~qu'pment sOpp"er f°r final review and 'appr°va"
GENERAL WiND PROTECT[ON CONNECT[ON NOTES PLUMBER CERTIFICATION
~]~a~ed from Standard for Hurricane Res[stard Reslderdial Construction; SSTD 10-99 ON LEAD CONTENT BEFORE
and 1995 SEC High Wind Edition Wood Frame Conslmction CERTIFICATE OFOCCuPAN~y,i
r?~steners and Connectors for Wood Frame Consbuction ' Jl'
t. A continuous load path between footings, foundations walls,,, boors, studs and roof ; 'SO[DER USED iN wATER
2. If wall plates or joists are cut during the installabon of plumbing fixtures or
equipment provide bracing to tie framing back together.
GENERAL HVAC SYSTEM NOTES
~UPPL~ Y S~q_ TEM CANNOT
framlngshallbeprovided. ~ /~'~" EXCEED 2/~ ~ OF l % LEAD. ,
2. Approved connectors, anchors and other fastening devices not included in the -~ ' '
Standard Bugdthg Code, Table 2306.1 shall be installed in acccordance with
3, Metal plates, connectors, screws, bolts, and nails exposed Idlrectiy to the weatLher or ALL CONSTRUCTION SHALL
galvanized. MEET THE REQUIREMENTS OF THE
CODES OF NEW YORK STATE.
4, Where windows and doors interrupt wood structural panel s~heathing and siding,
5. Ridge straps shall be attached to each pair of opposing taft,em except where collar PLUMBING
lies of I x6 or 2x4 lumber is located in upper third of attic specie and attach to each pair ALL PLUMBING WAS'tN
of rafters, & wATER LINES NEED
6. Uplift connectors shall be provided at each ratter beadng,
7. Floor to floor hold-downs to be provided every 4fi, and every 16" within 4' of extedor
come~. RETAIN ~I'OR~ WATER RUNOFF
8. Sill Plate to Foundation Anchorage: Sill plate shall be anchlored to the foundation PURSUANT TO CHAPTER 2~
with anchor bolts having a min. bolt diameter of 5/8" and 3" x 3" x 1/8" washers. A 0F THE TOWN COBE
minimum of one anchor bolt shall be provided within 6 to 12 thmhes of each end of
spacing not exceeding 4 feet on center.
THESE NOTES ARE GENERAL CONSTRUCITON NOTES. THEY ARE NOT
SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO, BE CONSIDERED AS
GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSS,ED WITH YOUR
GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS.
TABLE 3.7
; RAF~TcR SPAQNG 16' Q/~ ' :
1; 2( 28 3E
3:12 11 14
4:12 8 11
5:1~ 7
7:1~ 5
9.1~ 4
12.1~ 31 3
RE~IRED :,
CERTIFICATION OF'
NA LING.& CONNEC,TIONS
BEQUIRED,,E,
INAILING SqH. E-DU~'E ~
~ELE 3.1, iNCLUDING 3 3 AND ~ 9 ' i I
1995 SEC HIGH WIND EDITION WOOD FRAM ~ CONSTRBCTION MANUAL
A~T~ ~ TO TOE PLATE
CEILING JOIST TO TOP PLATE ~O; ;AILED
RIM BOARD f~ R~FTEB ~N~ NAILED
JOINT DESCRIPTION I NIAIL QUALITY NAIL SPACING
E'-0"'W ALL' ~-~d PER RAFTER
~0'-0" WALL 4-~d PER RAFTER
8'-0" WALL 3-~Jd PER JOIST
10'-0" WALL 4-8d PER JOIST
~EE TABLE 3 7 EACH LAP
SEE TABLE 3 7 EACH LAP
S~E TA~_L.E 3,,4 PER TiE
2-8d EA~B END
2-16d EACH END
WALL FRAMING
TOP PLATE TO TOP PLATE IFACE NAILED 2-16d *
TOP PLATES ~.T.I~T~[~S__ECTION_S. ?AbE N~IL~F_ . 4-16d
STUD TO STUD iFACE NAILED
R~AD~R'TO H~Ab~ ]~AbE NAILED 16d
TOP OR BOCTOM PLATE TO STUD 4(N~NA!L.E_D . - 2-16d
4-1 Ed
BOTTOM PLATE T6 FLOOR JOIST,
BAND JOIST, END JOIST, OR BLOCKING [FACE NAILED 2-18d * ~ PER FOOT
FLOOR FRAMING
B'RIDGING TO JOIST~'' ~TOE BAILED 2-8d EACH END
BL'OCKIN~ ~O JOI~T !TOE NAILED 2-8d
ELOCKIN~ ~O SILL OF: TOP eLATE ~OE ~AILED , 3-1Sd .EACH BLOC
........ It6~ NAIL~b 3-Ed P~R JBIST
PER FOOT
JOINTS - EACH SIDE
24"I
18" CiO ALONG EDGES
PER 2X4 STUB
PER 2X6 STUD
~e 2k8 STUD
JOIST ON LEDGER TO BEAM
BAND JOIST TO JOIST IEND NAILED 3-16d PER JO~ST ]
J
STRUCTURAL PANELS I 4' PE RIM ETER EDGE ZONE 16 O/C - B" AT PANEL /
EDGES AND AT INTERMEDIATE SUPPORTS IN THE
i ~d PANEL FIELD I
' i ----INTERIOR ZONE - 18" CfC - 8" AT PANEL EDGES AND 12" m
8d iAT BTERM EDIATE.,, ~,. SUPPORTS IN THE PANEL
FOR ROOF SHEATHING W rTHIN 4'-0" OF THE PERIM ETE R EDGE OF TH E ROOF, INCLUDING 4-0 Oh EACH SIDE OF THE ROOF PEAK, THE 4-0
PERIMETER EDGE ZONE ATTACHMENT REQUIRE M ENTS S HALL BE U~ED
~-Yp~'uI~I'W~L~EOKF:d ..... j fid COOL~RS
WALL SHEATHING
~T~USTtJ~AL'¢~N~LS ' , - 8d ' 4'~DGE ZONE ~ ~ O/C -6" AT ~ANEL EDGES AND 12"
, ' ]j . A~-TERM~IATE SUPPORT. S IN TEE PArt~L FIELD
i 8d INTERIOR ZONE -lC" o/c- 6' AT PANE L EDGES AND 12"
i ~~TE SUPPORTS IN THE PANEL FIELD
CTI3ERSOARD PANELS 17/16" 6d 3" EDGE / ~" FIELD
i25~32" Bd 3,' EDGE / 6' ,FIELD
GYPSUM WALLBOARD- ] -' ' 5d COOLERS 7,; CD~-E ! 10' ~rELD ;,
rTABLE 3.4[
I CLIMATIC AND GEOO.~A, HIC DESI¢~N CRITERIA
ROOF ROOF NUMBER
PITCH SPAN (ft) OF NAILS
4 12 12
1§
20
26
32
TERMITE
M~[~ERATE TO HEAVY
DECAY SLIGHT ]0 MODERATE
WINTER DESIGN TEMP 11
iCE SHIELD UNDER ~S PER MANUFACTURER'S
LAYMENT REQUIRED ~EECIFICATIONS / STATE CODE
FLOOD HAZARDS
SOUTHOLD BUILDING DEPARTMENT CRITERA
OCCUPANCY CLASSIFICATLON R~3 R[SIDENTIAL - SECTION 310 BUILDING CODE N.Y.S.
JSE DWELING UNIT - SECTION 310 - 310.2
2 HEIGHT TOTALi28'-5"
FIRE AREA (sO 2ND FL!850 SQFT
: TYPE OF CONSTRUCTION WOOD FRAME CONSTRUCTION
~ DESIGN CRITERIA PRESCRIPTIVE DESIGN - 1995 HIGH wIND EDITION WFCM
~ FRAMING ELEMENTS SEE FLOOR PLANS AND SECTIONS
E DESIGN LOAD CALCULATIONS SEE PG 8,9,10 i
7 ¢VlNDOWAI~4D DOOR SCHEDULE ~EEPG 12 ~
~ LOAD PATH SEE PG 8,9,10 i
E NAILING SCHEDULE SEEPG 11 ~
1{ EGRESS SEEPG 12 i
11 ~LUMBING RISER DIAGRAM SEE PG 12 r,
12 FlEE PROTECTION N/A ~
13 TRUSS DESIGN DRAWINGS ~A i
14 ENERGY CALCULATIONS SEE A~FACHED
O
O
--W
Lt.
I- ~ 0 ~- ~1-
0~0~
~00
FBBNT ELEVATION
SCALE~ 1/'4"=~-'-0''
33'-0~"
a5,-6~~
RIGHT ELEVATION
SCALE~ 1/4"=1'-0"
0
0
REAR ELEVATION
LEFT ELEVATION
SCALEI 1/4"=1'-0"
0
0
t
I
2
III
iT' 7
FIRST FL, PLAN
SCALE', 1/4"=1'-0"
5,.¢/
17¸
0
0
t
-- r
La' 8'
i?' 8"
13' 9"
~ 3' 9' '3' 10"
I? Ill HI
L4' 5
' m
rS'
16
0
0
SECBN3 FL, PLAN
SCALE~ 1/4":1'-0"
SECTII3N E-E ~
SCALE, 1/4"=;'-0" C ~ i~l,~
II 14 I I 14
WlNDOWAND DOOR ..~ uJ ~- ~- ~
SCHEDULE
SYMBOL MODEL NUMBER WINDOW TYPE CLEAR GLASS EfFIOTIVE PRESSURE REQ. DESIGN DESIGN PRESSURE
OPFNING AREA WIND AREA 7ONF PRE~ 'lJRF RATING
A C24 400 SERIES CASEMENT 4,3 11,8 10 FOUR/FIVE 25,9 -34,7 50
WINDOW AND DOOR
SCHEDULE
SYMBOL MODEL NUMBER WINDOW TYPE CLEAR GLASS EFFICTIVE PRESSURE REQ. DESIGN DESIGN PRESSURE
OPFNING AREA WIND AREA 7ONF PRE~ 'lJRF RATING
A C24 400 SERIES CASEHENT 4,3 11,8 10 FOUR/FIVE 25,9 -34,7 50
B CXW15 400 SERIES CASEMENT 11,5 lB,2 10 Fr]UR/FIVE 25,9 -34,7 50
C CW25 400 SERIES CASEMENT 7,5 1813 10 FOUR/FIVE 25,9 -34,7 50
D PSOSO PICTURE 12,0 10 FOUR/FIVE 25,9 -34,7 35
ALL WINDOWS TD BE ANDERSON HIGH PERFORMANCE UR APPROVE]] EQUAL
CALCULATInNS FOR WINDOWS BASED UPON WALL OPENINGS INCLUDING WINDOWS AND Dr]fIRS SHALL BE PROTECTED WITH REMOVABLE 5/8~
EXPOSURE B COEFFICIENT 1,D WITH 1BO MPH BASIC WOOD STRUCTUAL PANELS ~¢ITH MAXIMUM EF 8'-0" SPAN FASTNERS FOR SPANS UP TO
WIND SPEED, AS PER TABLE R 3D1,E (2) NEW SHALL BE 2 1/2' -~B WOOD SCREWS @ lO'nC, FASTNERS FOR SPANS UP Tn O'-O" SHALL BE E
YORK STATE BUILDING CODE, 1/2" -#E WDUD SCREWS @ 1E'OC TABLE 301,2,1,2
ALL NAROWLINE WINDOWS MUST USE~
1/2' HT, SILL STOP (OR STOOL) AND THE ADDITII~N OF A 1/2" X 3/4' DP UPGRADE SILL STOP,
(SILL STOPS TOTAL A 1 1/4~ HT, AND REQUIRE THE INSTALLATION OF A SPECIAL SASH LIFT ~4 MUST HAVE DP UPGRADE KIT,
INCLUDED WITH DP UPGRADE SILL STOP KIT, E MEETS NY STATE EGRESS REQUIREMENTS
C CW25 400 SERIES CASEMENT 7,5 18,3 10 FOUR/FIVE 25,9 -34,7 50
STRUCTURAL WOOD PANELS FOR WIND-BORNE DEBRIS PROTECTION D P3050 PICTURE 12,0 10 FOUR/FIVE 2519 -34,7 35
MULTIPLE SECTION ASSEMBLY: 1t4"
THICKBOLTS@2'OC ALL WINDOWS TD BE ANDERSON HIGH PERFORMANCE UR APPROVED EQUAL
/ CALCULATInNS FDR WINDOWS BASED UPDN WALL OPENINGS INCLUDING WINDDWS AND DOORS SHALL BE PROTECTED WITH REMOVABLE 5/8~
EXPOSURE B COEFFICIENT 1,D WITH 1BO MPH BASIC WDDD STRUCTUAL PANELS ~¢ITH MAXIMUM DF 8'-0' SPAN FASTNERS FOR SPANS UP TD G'-O"
WIND SPEED, AS PER TABLE R 3D1,E (2) NEW SHALL BE 2 1/2' -~B WOOD SCREWS @ lO'nC, FASTNERS FOR SPANS UP Tn O'-O" SHALL BE E
/ YORK STATE BUILDING CODE, 1/2" -#8 WDUD SCREWS @ 1E'OC TABLE 301,2,1,2
ALL NAROWLINE WINDOWS MUST USE~
~- (SILL STOPS TOTAL
× I INCLUDED WITH DP UPGRADE SILL STBP KIT, E MEETS NY STATE EGRESS REQUIREMENTS
N.T.S.
STAINLESS STEEL WOOD SCREW ~ 16II O.C. OR B~TTER
ALTERNATIVE FASTNER FOR SHUTTER TO BUILDING: SHC NER SA' H
SHUTTER ASSEMBLY
SPECIFICATIONS AND ASSEMBLY IDENTICAL TO 0 < 4'-0" SPAN.
2x4 STRONG-BACKS @ 24" CC
ASSEMBLY'
1). PREASSEMBLE PLYWOOD TO 2x4'S: # 10x3" (wi WASHERS) GALVINIZED OR STAINLESS STEEL
SEC NER D.W. ~ W.M. II
TABLE 1609.1.4
ANEL SPAN < 2' :I- II pANEL ''OI L < L SLOPE 1/4 PER FOOT PITCH TO DRAIN HOUSE SEPTIC SYSTEM
N T.S.
FASTENER SPACING (INCHES)
~ANEL SPAN < 2' 2'-aI' · pANEL 4'-0' < PANEL 6 DI < PANEL
:ASTENER TYPE J" SPAN ~ 4'-0" ~P^N · 6' 0" SPAN ~ 8'-8"
1/2" ~6 WOOD SCREWS 10 16 12 g
1/2" #8 WOOD SCREWS 10 qB 16 12
RIDGE
RAFTER ~ ~ ~
USP R8250 AT 21'
i KING STUDS
RIDGE ~FTER STUD
I TOP PLATE TOP PLATE
, USP RT3
USP RT20 ~ USP RS250
USP LS ORTMU 1 ~ WALL STUD ~ ~ WALL STUD ~ -~ I JACK STUDS USP RS250 AT 12"
~FTE~RIDGE/~FTER w~o CT ~FTE~PLATE/STUD ~FTE~PLATE PLATE/STUD HEADE~STUD HEADE~JACK
POST ~
~ ~ ~ P.C. FOOTING
/
I
2ND. FLOOR PLATE ~~ 2ND' FLOOR PLATE POST ANCHOR FOR COVERED PORCHES
~ / ~ ~ ~ / ~ 1ST. FLOOR PLATE 1ST. FLOOR P~TE~
SUBFLOOR
USP KLFTA ~ USP RS250 AT 36 .... ~ USP RS250 AT 36" ~ USP RS250 AT 16"
1ST. FLOOR TOP P~TES 1ST. FLOOR TOP PLATES ! DOUBLE SILL P~TE ~ USP MPOF
' 1ST FLOOR WALL STUD ~ '~ 1ST FLOOR WALL STUD ---- - ~ , FOUNDATION WALL ~ FOUNDATION WALL I ~~ ~, ~ USPPAU
WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS
USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY.
STAIR TREAD
RIM BOARD
STRINGER
STRINGER
WOOD JOIST
GIRDER/HEADER
WOOD JOIST
STAIR
4" DIA. MAXIMUM
1-1/2" SPACE
MINIMUM
4" DIA. MIAXIMUM N ~-
LIIJ UL
DECK/PORCH RAILING
GIRDER/HEADER
POST/COLUMN
POS~T-TO-GIRDER/H EADE~ CONNECTION
USE MIN. (2) 1/2" DIA. GALV. BOLTS WITH WASHERS AND NUTS
HANDRAILS
BALUSTERS
OPEN BALUSTER
ATTACHED TO WALL
HANDRAIL CONNECTION
ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH
OF THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS
SHALL NOT BE LESS THAN 1-1/4" NOR MORE THAN 2" IN
CROSS SECTIONAL DIMENSION, OR THE SHAPE SHALL
PROVIDE AN EQUIVALENT GRIPPING SURFACE
TO DECK/PORCH CONNECTION
FLUSH JOISTS WITH HEADER/GIRDER
ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH
THE PROPER STEEL CONNECTOR.
IF ABLE, SET FIR JOISTS APROX. 1/4" HIGHER THAN LVL HEADERS
TO ALLOW FOR SHRINKAGE.
POST
RIM/DECK JOIST
POST-TO-DECK CONNECTION
USE MIN. (2) 1/2" DIA. GALV. BOLTS WITH WASHERS AND NUTS
GIRDER/HEAIDER
POST/COLUMN
POST-TO-GIRDER/HEADER CONNECTION
LOCATION USP NUMBER DESCRIPTION
4x4 SOLID COLUMN PBS44 / PBSE44 / KC44 POST CAP ANCHOR
6x6 SOLID COLUMN PBS66 / PBSE66 / KC66 POST CAP ANCHOR
HOLLOW COLUMN SIMPSON STRR1/2 H.C. ANCHOR
APPLICATION
APPLY TO EACH COLUMN
APPLY TO EACH COLUMN
APPLY TO EACH COLUMN
JOIST
GIRDER/HEADER
SPLICED JOISTS OVER HEADER/GIRDER
LOCATION USP NUMBER DESCRIPTION APPLICATION
JOIST TO G RDER/HEADER RTl0 TYDOWN ANCHOR CONNECT TO EACH JOIST
GIRDER/HEADER
POST/COLUMN
GIRDER/HEADER
TO POST/COLUMN CONNECTION
FLASHING TUCKED UNDER
TOP PIECE OF SIDING AND
LAPPED OVER FIRST CONTIN.
PIECE OF SIDING BELOW
1/2" DIA. LAG BOLTS W/WASHERS
CONNECTED TO BLDG. @16" CC
FLOOR FRAMING
2x JOISTS
BLOCKING FOR
LAG BOLTS
RIM JOIST /
JOIST HANGER
DECK/PORCH LEDGER CONNECTION
WOOD JOIST --
BLOCKING
WOOD GIRDER
SPLICED JOISTS OVER HEADER/GIRDER
PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND
USE WITH RTl0 TYDOWN ANCHORS
POST
12"x12"xl 2"
CONCRETE FOOTING
DECK POST FTC. CONNECTION
LOCATION USP NUMBER DESCRIPTION APPLICATION
4X4 POST PAU44 OR WE44 POST / BEAM ANCHOR APPLY TO EACH FOOTING
6X6 POST PAU66 OR WE66 POST / BEAM ANCHOR APPLY TO EACH FOOTING
GIRDER
CONCRETE PIER
HEADER/GIRDER-TO-POST CONNECTION
LOCATION USP NUMBER
(2) IBEAMS PAU44 OR WE44
(3) BEAMS PAU66 OR WE§6
DESCRIPTION
POST/BEAM ANCHOR
APPLICATION
APPLY TO EACH PIER
POST / BEAM ANCHOR APPLY TO EACH PIER
UNDISTURBED SOIL
LAY PLASTIC BASE DIRECTLY ON
UNDISTURBED SOIL (ORGANICS REMOVED)
LEVEL BASE
FIT CONSTRUCTION TUBE AND PLUMB
BRACE TUBE
FILL AS PER MANUFACTURES' INSTRUCTIONS
DISTURBED / POOR SOIL
LAY 4-6" LAYER OF CRUSHED STONE OR
GRAVEL
LEVEL AND COMPACT BY HAND
LAY PLASTIC BASE ON COMPACTED GRAVEL
LEVEL BASE
FiT CONSTRUCTION TUBE AND PLUMB
BRACE TUBE
FILL AS PER MANUFACTURES' INSTRUCTIONS
CONC. PIER FOOTING
BIGFOOT SYSTEMS FOOTING FORM
IN ACCORDANCE WITH SECTION 104,11 OF N.Y.B. REBIDENTIAL CODE THIB DESIGN
COMPLIES WITH THE INTENT OF THE CODE AND THE MATERIAL OFFERED IS
AT LEAST THE EQUIVALENT IN DURABILITY AND EFFECTIVENESS OF THAT
PRESCRIBED IN THE CODE.
THE DIVISION OF CODE ENFORCEMENT AND ADMINISTRATIONB FINDS THIS PRODUCT
ACCEPTABLE FOR USE IN N.Y.S. BASED UPON ICBO EVALUATION SERVICE REPORT
ER-5495, AND SUBJECT TO THE CONDITIONS THEREIN.