HomeMy WebLinkAbout35962-ZS-2 EXISTING BARGE STRUCTURE (APPROXIMATE LOCATION) I I REMOVE EXISTING WOOD AND CONCRETE FLOORING IN THE HATCHED AREA. PROVIDE TEMPORARY SUPPORT FOR EXISTING WALLS TO REMAIN EXISTING qTR, Y TO P. EMA MAIN ENTRY NO WORN r r PROVIDE TEMPORARY SUPPORT TO EXIST. WALLS TO REMAIN (TIr'P.) NO WORK PECONIC ~3AY KEY MAP NO WORK b MEET EXISTING CONCRETE FLOOR (APPROXIMATE LOCATION V.LF.) NO'YORK II I Scale: 1/4:1-0 Drown by: J JO Date: 12/2112009 Design Loads: - Ground Floor - Live Load - 100 ps[ - Dead Load - 50 ps[ REVISIONS uonaon -nglneermg, · 1.7,55, S[g, sb~ Road J $OUTHOLD, NEWYORK I MattI~UCK, New YOrk 11952 ...... (631) 298-1986 (63!) 29~-2651 FaxJ ............. I www condonenglneenng corn j FLOOR REPAIR PLANI EXISTING CMU FOUNDATION WALL V I·F. EXISTING CMU FOUNDATION WALL V.I.F. -- EXIST, CRAWL EXIST· CRAWL REMOVE EXISTING WOOD AND CONCRETE FLOORING, FLOOR JOISTS AND DEBRIS PROVIDE TEMPORARY SUPPORT TO EXIST. WALLS TO REMAIN EXIST. CRAWL EXISTING CMU FOUNDATION WALL V.I.F. -- EXISTING TEMPORARY SHORING AND DEBRIS TO BE REMOVED EXISTING TIMBER BARGE STRUC3~IRE TO REMAIN EXISTING CONDITIONS FLOOR SECTION SCALE: 1/2"=1q)' NEW 4 1/2" CONCRETE SLAB EXIST. CRAWL FILL INTERIOR OF BARGE WITH CLEAN SAND __ AND GRAVEL TO BOTTOM OF SLAB LEVEL (SEE CONTROLLED FILL NOTES) PROPOSED IFLOOR SECTION EXISTING GRADE EXISTING CMU FOUNDATION WALL V.I.F. GENERAL NOTES: THE CONTRACTOR IS TO VERIFY ALL MEASUREMENTS IN THE FIELD AND ANY DISCREPANCIES ARE TO BE BROUGHT TO THE A3TENTION OF THE ENGINEER PRIOR TO CONSTRUCTION. 1. 1 - ALL CONCRETE 3,500 PSI AFTER 28 DAYS MINIMUM. 2. 2 - ALL RESAR ASTM A~15 GRADE 60. 3. THE FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE PLUMBING AND ELECTRICAL CONTRACTORS RELATIVE TO INSTALLATION OF SLEEVES AND OTHER PENETRA~ONS PRIOR TO POURING CONCRETE. CONTROLLED FILL NOTES: 1. DEWATER AND REMOVE DEBRIS PRIOR TO INSTALLATION OF THE BACKFILL. 2. THE EXISTING EARGE TIMBER FLDOR AND WALLS ARE TO REMAIN. REMOVE ANY ROTTED OR DAMAGED TIMBERS AS NECESSARY TO INSTALL THE NEW FLOOR 3. RACKFILL THE INTERIOR OF 3HE BARGE WITH CLEAN MATERIAL (SAND AND GRAVEL) TO THE BOTTOM OF FOOTING ELEVATIONS. THE BACKFILL IS TO BE MECHANICALLY COMPACTED IN 6 INCH LIFTS. EACH LAYER IS TO BE COMPACTED TO g8% MODIFIED PROCTOR. A CLEAN FINE'RAINED MATERIAL WITH AT LEAST 10 TO 30% OF pARTICLES PASSING A NO. 100 SIEVE BUT NOT CONTAINING SILT, OR ORGARIC MATERIAL IS RECOMMENDED. 4. THE COMPACTED MATERIAL SHOULD BE TESTED PERIODICALLY TO DETERMINE THAT THE 98% MODIFIED PROCTOR COMPACTION RATE IS ACHIEVED. 5. RECYCLED CONCRETE AGGREGATE (RCA) OR GRAVEL MAY BE SUBSTITUTED FOR THE CLEAN SAND AND GRAVEL MATERIAL. NEW 4 1/2" CONCRETE SLAB \ //4 REBAR ~ 18' O.C. ~ '~- 10 MIL POLYETHYLENE VAPOR RETARDER ~ COMPACTABLE GRANULAR FILL PROPOSED FLOOR SECTION SCALE: 1'=I'~9" 4" MIN. OR MATCH WALL WIDTH 518" 13 X 12" LONG GALV ANCHOR BOLTS AT 28" D.C. MAX., 12' MAX FROM CORNERS C~OPPER TERMITE SHIELD 2X4 ACQ SILL FOAM SILL SEAL -- EXISTING CMU FOUNDATION WALL PROPOSED FLOORSECTION AT EXTERIOR WALL Scale: AS SHOWN Drawn by: JJC Date: 12/21/2009 Condon Eng neenng, P.C. 1755 SigsbeeRoad Ma~tuck, NeWYork11952 (631) 298-1986 (631) 298-2651 Fax www.condonengineedng.com REVISIONS OLD BARGE RESTAURANT MAIN ROAD (ROUTE 25) $OUTHOLD, NEW YORK FLOOR REPAIR SECTIONS AND DETAILS S-2