Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
35767-Z
Town of Southold Annex 54375MainRoad Southold, New York l1971 9/1/2011 CERTIFICATE OF OCCUPANCY No: 35188 Date: 9/1/2011 THIS CERTIFIES that the building Location of Property: SCTM #: 473889 Subdivision: ADDITION/ALTERATION 2875 BAY SHORE RD GREENPORT, Sec/Block/Lot: 53.-6-2 Filed Map No. Lot No. filed in this officed dated dated 8/11/2010 conforms substantially to the Application for Building Permit heretofore 6/23/2010 pursuant to which Building Permit No. 35767 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and additions, including conversion of garage to living space, breezeway, outdoor shower and second floor balcony, to an existing one family dwelling as applied for per ZBA #6374, dated 6/10/10. The certificate is issued to Anderson, James & Ellis, Rosemary (OWNER) of the aforesaid building. SUFI~'OLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 8/31/11 35767 5/16/11 South~d Plumbing & H/eating ' Authc~r~'ed Signaturea''- FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35767 Z Date AUGUST 11, 2010 Permission is hereby granted to: ANDERSON & ELLIS 2875 BAY SHORE RD GREENPORT,NY 11944 for : ADDITIONS & ALTERATIONS TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 2875 BAY SHORE RD GREENPORT County Tax Mmp No. 473889 Section 053 Block 0006 Lot No. 002 pursuant to application dated JUNE 23, 2010 and approved by the Building Inspector to expire on FEBRUARY 11, 2012. Fee $ 710.00 ORIGINAL Rev. 5/8/02 Form Ho. 6 TOWr OF SO rmoLD BUmOn G VEPARTMEm- TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF occUPANcy This application must be f'flled' in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey,of property with accurate location of all buildings~ pmpe~y lines, streets, and unusual natural- or .topographic features. ' - · 2. Final Approval from Health Dept of water supply aud sewerage-disposal (8_9 form)_ 3-. Approval of electrical iustallation from Board 0f Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in syst~n contains less than 2/10 of l%'lead. · 5. Commercial building, industrial building, mdltiplc n~id~oes and similar buildings and installations, a certificate of Code Compliance from arohiteet or ~ngineer reepousiblc for the building. 6, Submit Planning Board Approval of completed site plan requirements. B. F~r exi~ting bui~dings (pri~r t~ Apr~ 9~ ~957) n~-c~nf~rming uses~ ~r bui~dings and "pre-existing~ ~and uses:~ 1. Accurate survey of property shgwing all property lines, streets, building and:unusufil natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building InSpector shall state the reasons therefor in writing to the applicant. C. Fees 1. C~rti~ca!e ~f Occupancy ~ New dwe~~ing $5~~~~~ Additi~us t~ dw~~~ing $5~~~~~ A~terati~us t~ dwe~~ing $5~~~~~ · Swimming pogl $50.00, Accessory building $50.00, Additions to accessory building $50 00, Businesses $50.00,. 2. Ce[tificate of Occupancy on Pre~cxisting Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 - 5. Temporary Certificate 0fOccupancy ~ Residential $15.00, Commercial $15.00 New Construction: Location or Property: House No. ~ ~ 0~ ofPm~y:. ~ ~ T~ ~ No 1 ~, 8~6on 8u~si~n . . Old or Pm-existing BufldLng: Peimitl%. 55~6 7 .DateofPennit (check one) · - Hamlet BlOCk Lot Filed Map. Lot: . Applicant: H~mlth I)ept Approval: ~ Planning Board Approval: .~equest for: Temporary Certificate :ec Submitted: $ ~-) ~ Underwriters Approval: ~ l Final Certificate: t~ (check one) Town Hall Annex 54375 Main Road P.O. Box I 179 Southold, New York 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 roger, richert~town.so uthold, ny. us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ~ssued To: James Anderson Address: 2875 Bay Shore Rd City: Greenpod St: NY Zip: 11944 Building Permit #: 35767-35768 Section: 53 Block: 6 Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Shore Power Electric License No: 42536-me SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Oommerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Servicelph ~ Heat ~ DuplecRecpt ~ Service 3 ph Hot Water GFCI Recpt Main Panel NC Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment: Ceiling Fixtures ~ HID Fixtures Wall Fixtures ~ Smoke Detectors Recessed Fixtures ~ CO Detectors Fluorescent Fixture ~_~ Pumps Emergency Fixtures[~ Time Clocks Exit Fixtures ~ TVSS 200a over head service, 4-exhaust fans, 4-paddle fans, 4-arc fault circuit breacker Notes: Inspector Signature: Date: Ma)/16 2011 81-Cert Electrical Compliance Form Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 76571802 Fax (63 I) 765-9502 BUILDING DEPARTMENT TOWJSI OF//[OUTHOLD Plumber: CERTIFICATION (Please print) lead. I certify that the solder used in the water supply system contains less//~hanz~ 1% ' ~ers~ignature) Sworn to before me this / ~t~ day of-~]PA3~ - , 20 / / Notary Public, ..~d~\ [( County TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [~,,FOUNDATION 1ST [ ] ROUGH PLBG. [~OUNDATION 2ND [ ] INSULATION ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE&CHIMNEY [ ] FIRESA~.'I~'INSPECT'ION [ ] FIRE RESISTANT C~~j~_.,~RESISTANT PENETRATION REMARKS: ~.? -~ .... ~ DATE TOWN OF SOUTHOLD BUILDING DE~. 765-1802 .~_~/q~-- INSPECTION [ ] FOUNDATION 1ST [" ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] flRERES~TANTCONSTRUCT~N__/ [ ] F~ERES~TANTFENETRAT~N REMARK .S~ h~/~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]RRE RESISTANT CONSTRUCTION [~ELECTRICAL (ROUGH) [ ] ROUGH PLBG. [ ]INSULATION [ ]FINAL [ ]FIRE SAFETY INSPECTION [ ]RRB RESISTANT PENETRATION [ ]ELE~i.ICAL (FINAL) REMARKS: INSPECTOR~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] ROU/GH PLBG. [/.-.]-4NSU LATION FRAMING / STRAPPING [ ] FINAL F,.EPLACE.~ C.,.NEY [ I F?~S~",~"NS"ECT~ FIRE RESISTANT CONSlllUCTlON [ '""1-FIIIE I:IESlSTANT PENETIIATION REMARKS~ ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING ~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONS]llUC'rlON [ ]FIRERE~TANTFENETRATION DATE __.~r______~__ l/ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY ROUGH PLBG. INSULATION FINAL FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ~LECTRICAL (FINAL) REMARKS: DATE iNSPECTOR'~~=~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ]INSULATION [ ]FINAL [ ]FIRE SAFETY INSPECTION ]RRE RESISTANT PENETRATION [ ] FIR£RESlST~ITCOHS~UCI~OH [ REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.neffSouthold/ Examined ,20 Approved ,20 Disapproved a/c .fl'.~ ~[~ Ii0 Expiration ,20 PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before epplsfing? Board of Heaith 4 sets of Build~ag Plans planning Board approval Survey_ Cheek Septic Form Trustees Contact: Marl to: ~LDG. DEPT, TOWN OF SOUTHOLD Building Inspector ATION FOR BUILDING PERMIT Date INSTRUCTIONS ,20/dP a. This application MUST be completely filled m by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of hit and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this apphcatinn may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole Or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every builaing permit shall expire if the work authorized has not commenced within 12 months aRer the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted ia the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Depar~aent for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other epplicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit author/zed inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicmat is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~bf~-~ ~:)gJl~r~OK) ~ ~O~-~A:~¥" (As on the *tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. I. Location o f land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section ~ Block ~v Subdivision Filed Map No. Lot (Name) censtruc, ti0n: 2. State existing use and occupancy of premises and intended use and occupancy of proposed a. Existing use and occupancy b. Intended use and occupancy ~/' 3. Nature of work (check which applicable): New Building Addition V'~ Alteration Repair Removal Demolition Other Work 4. Estimated Cost Fee ~ ~. ~ (Description) (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on ench floor If garage, number of cars 6. if business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front i~'.~( Rear ."~O ,~! Depth Height /2-~J~t Number of Stodes ~_ ' , t Dimensions of same structure with alterations or additions: Front 2.~ I Real :~,~ Depth ~,,¢,~,t Height ~.~}, ~,~ Number of Stodes Rear k Depth Depth/~---9.74 e 8. Dimensions of entire new ennstmction: Front Height. Number of Stories 9. Size of lot: Front /~:~(,-~t' Rear /~.~'~--! 10. Date of Purchase/2t,/~ZOl/t~ Name of Former Owner 11. Zone or use district in wttich premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES v/NO 13. Will lot be re-graded? YES NO excess fill be removed from premises? YES v/NO__ NemeofArchitect '- /~ Address;'~/~; ~-~r?r rnone~o Name of Contractor Address Phone No. 15 a. Is this property within 100 feet ufa tidal wetland or a freshwater wetland? *YES V/NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES__ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ~,~) ~/.//~" ~_.~/~/ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, CONNIE D. BUNCH (S)He is the ,~/'"f~/'~f~--~7~- No. 01BU$185050 performed in the manner set forth in the application filed therewith. Sworn to before me t hi..~ Notary Public Signature of Applicant TOWN OJ~ SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork. net Approved/ [ , 20 / 0 Expiration ~ -- / / , 20 I ~'~ JUN 2 3 2010 BLDG. DEPT. sets of ~lans, accurate plot plan to scale. F PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Conlaet: Phone: Building Inspector 'PLICATION FOR BUILDING PERMIT INSTRUCTIONS ,20 ~le~ly filled in by typewriter or in ink and submitted to the Building Inspector with 4 according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building F~,mit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certifica~ of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months at'~r the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Dqmrtment for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises ~A//~:-~ ~tt~'/~-~>.~'d~tO t (As on the tax roll o~ latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section ~-_~ Block O~ Lot ~--~ Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (cheek which applicable): New Building Repair Estimated Cost Removal Demolition If dwelling, number of dwelling units If garage, number of ears Fee Addition U/// Alteration ~// Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed oocupancy, specify nature and extent of each type of use. 7. Dimensions ofemsting structures, if any: Front /2~, ~ Rear ~,,~. Height ~?._~. ~2~ ~ Number of Stories ~_ Dimensions of same structure with alterations or additions: Front .~/ Depth ~-/,~ ! Height ~,~. ,,~ ( Number--'~-~tories 8. Dimensions of entire new construction: Front .Rear Height Number of Stodes · Depth Rear 9. Size of lot: Front /~',~ l O. Date of Purchase Rear Name of Former Owner 11. Zone or use district in which premises are situated ~ -- ~ O 12. Does proposed construction violate any zoning law, ordinance or regulation? YES /NO - / 13. Will lot be re- ed? YEs No /Wil] ex.ss be romoved ise$? YES /NO 14. Names of Owner of premises_~_g/,O~t~(~.~l~_~-.Addressz~.t~P.~.~¢~ //.~-/-PhOne No. ~ Name of Architect '~//1/~ ~4',~//-,g'/vW--~/,~/Address ~j~2~Phone No - - · Name of Contractor Addresc ~' ' Phone No. r 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES. O __ * IF YES, SOUTHOLD TOWN TRLIST.EES & D.E.C. PERMITS~IAY BE REQUIRED. b. Is this property within ~00 feet ora tidal wetland? * YES ~/ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and res~ictions with respect to this property? * YES __ NO ~// · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS' cot rv ~/7~' ~t'~'//~F)tS~/ being duly sworn, deposes and says that (s)he is the applicant ~e of individ~ s~g c~) ~ve ~ (Conm~or, ~enL Co~mte Officer, etc.) of ~d om~ or om~, ~d is duly ~ofi~ m ~om or ~ve ~om~ ~e ~d wo~ ~d to ~e ~d file ~ ~li~on; ~t fll s~en~ m~ in ~is ~li~fion ~ ~e ~ ~ ~t of his ~owl~e ~d ~lief; ~d ~ ~e work will ~om~ in ~e m~ s~ fo~ ~ ~e a~limfion fil~ ~wi~. Sworn to ~fom me ~is Notary Public CONNIE D. BUNCH Nota[y Public, State of New York No. 01BU6~85050 Qualified in Suffolk County I ~'~ Commission Ex~i~es ~ori~ 14? ~.0 ~ _~- S Town of Southold ~ Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.#: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A ~ ~ (.~ ~ STORM-WATER, GRADING, DRAINAGE AND EROSION CONTROL PLAN District Section Ble~l~ Lot CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. PROPOS~ CONS~U~ON ITEM# / WORK~S~SMEN~ ] Yes No SCOPE OF WORK a. What is the Total Area of tho Project Parcels? I Wit/this Project Retain All Storm-Water Run-Oft (Include Total Area of all Parcels located within t/~ ~. / "~ Generated by a Two (2") Inch Rainfall on Site? the Scope of Week for Proposed Constmctk)n) (S.F. I Ac~es) (This item will include all mn-oft created by site b. What is the Total Area of Land Clearing cleadng and/or construction activities as well as all and/or Ground Disturbance for the proposed ~'.~O ~'/1~ Site tmprovementa and the permanent creation of construction activity? impervious surfaces.) (s.F.~,.) 2 Does the Site Plan and/or Survey Show All Proposed PROVIDE BP, ZF~ PROJEC~ DESCRIPTION (Pro,de Ade~ Pag.s as Needed3 Drainage Structures Indicating Size & Location? This Item shall include all Proposed Grade Changes and d~'F~-~'~' ~'/O~,.~--~ . Slopes Controlling Surface Water Flow. V'RT"2~AJ xCrE'~<~: .~20~F'/x./~ ~",~,~,4_~ ,Z~__-~'~7-~. 3 DoestheSitePlanand/orSurveydeecribetheerosion . and sediment control practices that will be used to contrct site erosion and storm water discharges. This - Construction Period. --.2-- ~T~ 9' Z)/PrJ/77Z~/~J 4 Will this Project Require any Land Filling, Grading or ExcavatiOnGradeWhere there is a changethan 200t° the Natural J J 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand -- {~/*/~/~ EX,] ~)1~('~ ~ P (5,000 S.F.) Square Feet of Ground Surface? .~ .e~ e-~ ~._ Site? Is this Project within the Trustees jurisdiction General DEC SWppp Requirements: ~;~4~--~-Z~t~~--~-- '~-'~'--~--'~ '-~a~-. or within One Hundred (100')feet ora Wetland or disturbances of one (1) or more acres; including disturbances of less than one acre that are purl of a larger common plan that wi~ ultimately disturb one or more acres of land; 7 Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vertical Rise to including Construction activities invoDing soil disturbances of less than one (1) acre where One Hundred (100') of Horizontal Distance? I~1 -- the DEC has determined that a SPDES permit is required for storm water discharges. 2. The SWPPP shall describe the erosion and sediment central practices and where 9 Will this Project Require the Placement of Material, STATE OF NEW YORK, ..... CONNIE D. BUNCH (Owner, Contractor. Agent, Corporate Officer, etc.) .~._0..0.1BU6185050 , Owneran orre resentaUveofthe Owneror' wn~ ~uaLm~ ~l'f~O~t~,ualifl~h $aff make and file this application; that all statements contained in this application are true to the best-' ~ '-- ~'"-of h~s knowledge an-ffbelief; mid that the work will be performed in the mmmer set forth it] the application filed herewith. Sworn to before me this; ~ FORM - 06/t0 To~ H~i Annez .~1~7~ I~1~ R~ P.O. ~x 117~ · &xlltlold, ~ 11971-0959 TOWN' OF SOUTHOI.n APPLICATION. FOR ELECTRICAL INSPECTION Date: REQUESTED ElY: Company Name: ~o,~ ~. Name: ~n~. No.: Address.: ~,'~ P~ne No.: ~/ JOBSITE INFORMATION: (*Indicates. required information) ~RIEF DESC~ION OF WO~ (PI~ P~nt Cindy) *Is-jOb ready for inspe~n: *DO you need a Temp Certificat.e: Temp'lnformation (If needed}- Final *Sell/Joe S.ize: ~ 3Phase 100 150 ~ 300:~SL.~00 Other *New Servloe: Re-connect Underground ' Number of Metem ~-~"~e of Sej3A~I:~-di~aif% Additional Information: PAYMENT DUE WITH'APPLICATION , ~,_,~'~ FORM NO. 3 NOTICE OF DISAPPROVAL DATE: February 3, 2010 TO: Frank Uellendahl for J Anderson P O Box 316. Greenport, NY 11944 Please take notice that your application dated January 19, 2010 For permit for addition & alteration to an existing dwelling at: Location of property: 2875 Bay Shore Road, Greenport, NY County Tax Map No. 1000 - Section 53 Block _6 Lot 2_ Is returned herewith and disapproved on the following grounds: The addition & alteration to an existing dwelling is not permitted pursuant to Article XXII Section 280-116B which states: "All buildings or structures located on lots upon which a bulkhead.., exists and which are adjacent to tidal water bodies.., shah be set back not less than 75' from the bulkhead." The site plan indicates a setback from the bulkhead of 31.2'. ; - Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: ~e, Z.B.A BOARD OF SOUTHOLD TOWN TRUSTEES SOUTHOLD, NEW YORK PERMIT NO. 7259 DATE: MARCH 17~ 2010 ISSUED TO: JAMES G. ANDERSON & ROSEMARY ELLLq PROPERTY ADDRESS: 2875 BAY SHORE ROAD~ GREENPORT SCTM# 53-6-2 AUTHORIZATION Pursuant to the provisions of Chapter 275 and/or Chapter 1 i I of the Town Code of the Town of Southold and in accordance with the Resolution of the Board of Trustees adopted at the meeting held on March 17. 2010, and in consideration of application fee in the sum of $250.00 paid by James G. Anderson & Rosemary Ellis and subject to the Terms and Conditions as stated in the Resolution, the Southold Town Board of Trustees authorizes and permits the following: Wetland Permit to convert the existing attached garage into living space; construct a second-floor addition above the existing garage; construct a new 17'x25' garage with breezeway; install new windows and doors; existing roof above stoop to be removed and stone stoop to be widened, and construct a second-floor balcony above stoop; if necessary, demolition of existing garage to construct new foundation due to conditions during construction phase, with the conditions of the installation of a 10' wide non-turf buffer area along the landward side of the bulkhead, the installation of gutters, leaders and drywells to contain roof runoff and in aceordanee wlii~ Chapter 236 of the Town Code-Storm Water Runoff, and as depicted on the site plan prepared by Frank Uellendahl, Architect, last dated March 10, 2010, and stamped approved on March 17, 2010. IN WITNESS WHEREOF, the sa/d Board of Trustees hereby ~ases its Corporate Seal to be affixed, and these presents to be subscn'bed by a majority of the said Board as of this date. Jill M. Doherty, President Bob Ghosio, Jr., Vice-President James F. FAng Dave Bergen John Bredemeyer Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 0662C Date: June 28, 2011 THIS CERTIFIES that the conversion of existing attached garage into living space with second-floor addition; construct new garage with breezeway; new windows and doors; new brick patio; gutters to leaders to drywells; a 10' wide non-turf buffer to be maintained along the landward side of the bulkhead At 2875 Bay Shore Road, Greenport, New York Suffolk County Tax Map # 53-6-2 Conforms to the applications for a Trustees Permit heretofore filed in this office Dated February 18~ 2010 pursuant to which Trustees Wetland Permit #7259 Dated March 17, 2010 and Amended on June 22, 2011 was issued and conforms to all of the requirements and conditions of the applicable, provisions of law. The project for which this certificate is being issued is for the conversion of existing attached garage into living space with second-floor addition; construct new garage with breezeway; new windows and doors; new brick patio; gutters to leaders to drywells; a 10' wide non-turf buffer to be maintained along the landward side of the bulkhead The certificate is issued to JAMES G. ANDERSON & ROSEMARY ELLIS owner of the aforesaid property. ~t~orized Si~gnatu~r New York State Department of Environmental Conservation Division of Environmental Permits, Region 1 SUNY @ Stony Brook 50 Circle Road, Stony Brook, NY 11790-3409 Phone: (631) 444-0365 · Fax: (631) 444-0360 Website: www.dec.ny.gov LETTER OF NO JURISDICTION - TIDAL WETLANDS ACT March 25, 2010 Alexander B. Grannis Commissioner Mr. James G. Anderson 152 Warren Street Brooklyn, NY 11201 Re: Application #1-4738~03957/00001 Anderson Property - 2875 Bayshore Road, Greenport SCTM# 1000-53-6-2 Dear Mr. Anderson: Based on the information you have submitted, the Department of Environmental Conservation has determined that the property landward of the functional bulkhead greater than 100 ft. in length and constructed prior to 8/20/77, as shown on the survey prepared by Otto W. Van Tuyl & Son on 8/10/64 and I.R. 681, is beyond Tidal Wetlands Act (Article 25) jurisdiction. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a !5' to 20' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. George W. Hammarth Permit Administrator Cc: Frank W. Uellendahl, Architect, PO Box 316, Greenport, NY 11944 Marine Habitat Protection, NYSDEC File Office Location: Town Annex/First Floor, Capital One Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 ~ddmss: 53095 Main Road P.O. Box 1179 Southold, NY 11971-0959 http:#southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 Fax (631) 765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF JUNE 10, 2010 ZBA FILE: #637~' NAME OF APPLICANT: James G. Anderson and Rosemary Ellis SCTM# 1000-53-6-2 PROPERTY LOCATION: 2875 Bay Shore Rd. (adj. to Shelter Island Sound) Groonport, NY SEQRA DETERMINATION: The Zoning Board of Appeals has visited thc property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suttblk County Administrative Code Sections A '14-14 to 23, and the Suffolk County Department of Planning issued its reply dated March 2, 2010 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-cormmunity impact. LWRP: This application was referred for reviewed under Chapter 268, Waterfront Consistency review of the Tt~wn of Southold Town Code and the l~w~al Waterfront Revitalization Program (LWRP) Policy Standards. The LWRP Coordinator issued his reply dated May 17, 2010, based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well its the r~x;ords available to us, it is our recommendation that the proposed action is CONSISTENT with LWRP policy mandards and th¢rclbrc is CONSISTENT wifl~ the LWRP. It is recommended that a 10 fbot landscaped buffer be required landward from the wooden bulkhead. PROPERTY FACTS/DESCRIPTION: The property is a non-conforming 15,217 square toot lot improved with a two story masonry dwelling and attached garage. It has 100.94 tL~et on Shelter Island Sound, 146.51 feet along the southern property linc, 100 feet on Bay Shem Road and 159.74 feet along the northern property line. BASIS OF APPI,ICATION: Request for Variance fTom Code Section 280-116B, based on an application for building permit for addition and alterations, and Ihe Bnilding Inspector's February 3, 2010 Notice of Disapproval concerning addition and alt~ratioas to e~g dwelling, at less than fl~e code required setback from bulkhead of 75 feet. ILELIEF REQUESTED: Thc certified site plan submitted by Frank U01londall, Archit~31, dated ~IWI0, indicate~ a distunce el' 31.2' fi'om the bnlkhead. Plans indicate an extended front s~p, which is proposed, and is to be at 'tached to the principal dwelling on thi~ property. After In~pnndnn nC Ihn giro nrul iml~roveme.t dm=to, it ala~ea~ that thc primary dwelling has been in eXlUlont'~ i~'~ Ihi!; loc:dion well before the existence of Zoning in the Town of Southnld. AMENDED API'LICATI( }N: During the Public Hearing it was noted that the proposed sloop, located seaward of th'--c existing dwelling is proposed at 96 square feet and will need relief from the code required setback. The agent · P~ge 2- June )0,2010 ZBA File~637~.- Jame.~ G Anderson and Rosema~ Ellis CTM: 1000-53-6-2 for the applicant was to provide a signed and sealed letter attesting to the setback of the stoop to the bulkhead. The agent, Frank Uellendahl, Architect, submitted a letter, signed and sealed, dated May 20, 2010 stating that the setback of the stoop to the bulkhead is 28.1 feet, whereas thc proposed new second story seaward balcony is 31.2 ft as noted in the Notice of Disapproval FINDINGS OF FAC'IT REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on 5/20/201 O, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant and makes the following findings: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the fbllowing findings: Town Law §267-b(3)fb)(IL Grant of the variance of will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The applicant's parcel is under 20,000 sq. fl., which is 50% larger than (12) other lots in the immediate neighborhood. The immediate area that incorporates this public road, consists of many small improved lots. They are servicxxl with public water. The adjacent 50' lot~ are significantly substandard in width and area. Most of the existing lots, with improved primary dwellings exhibit varied setbacks, based upon these great non-conforming characteristics. The updating of this home will improve the character of the aeighborhood. Town Law §267-b(3)(b)(2). The benefit sought by the applicanl cannol be achieved hy some method, f~ible for the applic~t to p~sue, o~er th~ ~ arcs variaanc. ~m applicant c~not ~1~ his hom~ to a confo~ing setb~k wi~out ~eat ex,nsc. Based upon thc larger size cftc lek the position of~e home on the pamel, and the su~ding ~, fl~ pro~ucd setback is wMfin k~ping ofm~y o~cr e~t~g homes in the neighborhood. Town Law §267-b(3)(bj(3L The variance requested is substantial, it is a 57% reduction oftbe Code requirement. However, the applicant's home is 35.2' from the bulkhead, which lessens the percentage of the requested variance. Town Law §267-b(3}¢b)f4L No evidence has been submittcd to suggest that the granting of this variance will have an adverse impact on the physical or environmental conditions in this non-eonforming neighborhood. Town Law §267-b(3)(b)(5). The difficulty has been self-created. Although the dwelling existed prior to the zoning code, the owners purchased the dwelling with these existing non-conformities. Town Law §267-b. Grant of this variance is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an updated home, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of thc above factors and applying the balancing test under New York Town I.aw 267-B, motiou was offered by Member Goehrlnger, seconded by Member Weismtm (Chairperson), and duly carried, to GRANT, the variance as applied tbr, baaed upon thc curtilied site plus uubmitl~d by F, ank llellendahl, Architect, dated 2/! 2/211111, labeled as S itc Plan A-I, A-2, A-3, A4 and the signori and scaled letter dated hfgll/2010 by Frank IJclleudalll, Architect noting the setbaek of the sl¢R~p Io Ibc bnlkhcad is proposed at 28.1 foot. bray dcviution flora the score, y, site plan and/or architectural druwmSa cited h~ tiffs d*eigion will result in delays and/or a possible denial by Ibc ~uildlng Depmtment cfa building permil, amt may require u new application and public hearing before thc Zoning Board of Appeals. Any deviation from thc variance given such as ext~.sions, or domolitions which ur~ not shown on the applican;'s diagrams or survey site maps, are not authorized under Lhis application when involving nonconfonmtics under the zoning code. This a~lJon do~ not auUiorize or condone any current or £utur~ use., s~:tback or other fe~ature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other £mftur~s u.s arc gxpre, ssly addressed in this action. The Board reserves the right to substitute a simila~ design that is de minimis in nature for an alteration that do~s not increase 'ihe degree of nonconformity. Vote of the Board: Ayes: Members Goehringer, Weisman (Chairperson), Dtntzto, Schnetde . (Absent was: Member Horning) Thi~ Resolution was duly adopted (4-0). Leslie Kanes Weisman? Chai.rperson Approved for filing b, //~ /2010 / 12/15/2809 16:53 6317651956 I~V/I, NQ.NJ614.~N PA61; 82 u~.o~=~ ~CU~T~ ELEVATION CERTIFICATE N~er~ P4~ ~.m~e P~.~ ~ RMM Ihe Instn.~lo~ o~ IN~m 1-9. 12/15/2ee9 16:53 6317651856 PA6E 82 ELEVATION CERTIFICATE Impomm~ Reed the k~strudimu o~ pages 1,..0. Expkws Idarch ,31. 2012 I BUILDING PERMIT EXAMINER CHECKLIST *Date SuT~mitte..tt: ~--a23'7/0 Date Reviewed: PP - Owner. Architec~ '~~ ~ Estimated Cost.'-~ $CTM# 1000- ~-53... ~___ ~ Subd~ws~on: ~~fl~Zone: ~-~0 Conforming? ~0. PropertyAddr~s: ~ Z~ a~~ ~, ~ C'~: ~ PreCOs(~ Building Permits (Open/Expired): BP~ ~'ffi~ ~~ q ~-~ ~ ~ ~' ;Z ~- ~' ~~ BP -Z / ~0~ BP -Z/~0Z- ,Info: BP ~ -Z/~- ,h~o: ~ -Z/~0~ ,I~ S~gle & Separate Search Required? Y o etermination: ~Q. MtSize: ~ ,oo ACT. MtSize: ,~/~,~t~ar ~Q.~tCov. ~ ACT:~t~v. ~Q. Front ~ ACT. Front ~fl ~Q Side /~ ACT. Side a ~ ~Q. Re~ ~ PROP. ~Oej~}. ~ ACT. Height o~ ~~~~~ ~, rro]ect D~cr~ption. ~~ ~~~ ~? .~ ~ ~DITIONAL APPROVES ~UI~D - If no, certification required: Y or~ece~ved: Y or N By: Notes: Southold Trustees:~or N- Date: 3 / [~/~ Permit ~: ~ ~ ..... t,~r- Notes. 8outhold ZBA~r N - Date: / /~ Permit g: - Notes: 8outhold Planning: Y or~7 Date: ::/ / Permit ~: - Notes: Town Landmark C orA: Y o~DTE: ~/~/ *~S COD~. Cnmnlinnea (na~e 2~: Y ohN ,Fee Structure: Calculation: Foundation: 0 SF 1. ( ,g- I ~ SF)- (_ First Floor: ~"_5--0 SF Second Flooj: /,P3'73 ~\ SF Other: ,~ax~f~~SF 2. ( q~--,q'- SF)- (_ Total: "0--~-o23" SF SF)= ,¥ =$ + Initial ~ Fe :$ a2-oo, oo Additional Fee ( : $ SF X * .__i-',. ~ --~--~ ST ._%? A~dditional Fee ( ): ~~ ~ , TOt : $ o ~'~iAUG 9 2010 BLDG. DEPT. TOWN OF $OUTHOLD 0 NO TES: ~ 1. FLOOD FLOOD ZONE VE: SURVEY OF i!LOTS 47 & 48 MAP OF WlCKHAM PARK No. 644 FILED OCTOBER 4, 1927 SITUATE ARSHAMOMAQUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-53-06-02 SCALE 1'=20' NOVEMBER 25, 2009 AUGUST 5, 2010 ADDED FLOOD ZONES AREA : 15,217 sq. ff. (TO TIE LINE) 0.:549 aC. CERTIFIED TO: JAMES ANDERSON ROSEMARY ELLIS FIDELITY NATIONAL TITLE INSURANCE COMPANY ZONE X: ZONE INFORMATION TAKEN FROM:~ INSURANCE RATE MAP No. 36105~0159 H r COASTAL FLOOD WITH VELOCITY HAZARD (WAVE ACTION); BASE FLOOD ELEVATIONS DETERMINED DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED N.Y.S. Lic. No. 50467 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECllON 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAR NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE THE EXISTENCE OF RIGHTS OF WAY AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED. Nathan Taft Corwin III Land Surveyor Utle Su~eys -- Subdivisions -- Site Plans -- Construction Layout PHONE (631)727-2090 Fax (651)727-1727 OFFICES LOCATED AT MAILING ADDRESS 1856 Main Rood P.O. Box 16 Jomespo~, New York 11901 Jomespod, New York 11947 Generated by REScheck Package Generator Compliance Certificate Project Title: ANDERSON RESIDENCE Report Date: 06/22/10 Energy Code: Location: Construction Type: Heating Type: Glazing Area Percentage: Heating Degree Days: Construction Site: 2875 BAY SHORE AVENUE GREENPORT, NY 11944 Permit Date: 06.23.2010 2007 New Yom Energy Conservation Construction Code Suffolk County, New York Detached 1 or 2 Family Non-Electric 13% 5750 Owner/Agent: Designer/Contractor: FRANK UELLENDAHL ARCHITECT Ceiling; Wall: Window: Door: Floor: The propossd building represented in this with this permit application. The Code requirements. When a Registered Design Professional knowledge, belief, and professional Name - Title 38.0 17.0 0.0 0.450 0.350 the building plans, specifications, and other calculations submffted meet the 2007 New York Energy Conservation Construction ~ are attssting that to the best of his/her · compliance with this Cede. [~te [ Project Ti'de: ANDERSON RESIDENCE Report date: 06/22/10 Data filermme: Page 1 of 4 Generated by REScheck Package Generator Inspection Checklist Date: 06/22/10 Ceilings: [] Ceiling: R-38.0 cavity insulation Comments: Note: The ceiling R-values do not assume a raised or oversized truss construction. If the insulation achieves the full insulation thickness over the plate lines of exfa~or walls, R-30 insulation may be substituted for R~38 insulation and R-38 insulal~m may be substituted for R-49 insulation. Calling R-values represent the sum of cavity insulatio~ plus insulating sheathing (if used}. Above-Grade Walls: [] Wall: R-17.0 cavity insulation Comments: UPGRADED TO R-21 Note: Wall requirements apply to wood-frame wall consttuctlens. Metal-frame wall or mass (concrete, masonry, log) wall equivalent R-values con be found in the Help User's Guide. Windows: [] Window: U-factor: 0.450 For windows without labeled U-factors, deschbe features: #Panes Frame Type Thermal Break? Yes __ No Comments: Doors: [] Door: U-factor: 0.350 Comments: Front door exempt Note: Door U-values must be tested and documented by the manufacturer in accordance with the NFRC test procedure or taken from the door U-factor table in the Help Users Guide. If a door contains glass and an aggregate U-factor rating for ~at door is not available, include the glass area of the door with your windows and use the oflaque door U-factor to determine compliance for the door. One door may be excluded from this requirement (i.e., may bev a U-factor greater than 0.35). Floors: [] Floor: R-19.0 cavity insula~on Comments: Note: The floor requirements apply to floors over unconditlened spaces (such as unconditioned crawispaces, basements or garages). Floors over outside air must meet the ceiling requirements. Note: Add an additional R-2 for heated slabs. The insulation must extend 1 ) down feom the top of the slab, or 2) down from the top of the slab to the bottom of the slab and then horizontally underneath the slab, or 3) down from the top of the slab to the bottom of the slab and then horizontally away from the s~ab, with pavement or st least 10 inches of soil covedng the horizontal insulation, Air Leakage: Joints, penetrations, and all other such openings in rite building envelope that are sources of air leakage are sealed. Recessed lights are 1) Type lC rated, or 2) installad inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, fixtures are installed with a 3' clearance from insulation. Vapor Retarder: [] Installed on the warm-in-winter side of all n~m-ve~ted framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment are installed in accordance with the manufacturer's installation instructions. [] Materials and equipment are identified so that compliance can be determined. Manufac~rer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. Project Title: ANDERSON RESIDENCE Report date: 06122110 Data filer~me: Page 2 of 4 [] Insulation is installed according to manutacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without co(npressing the insulation. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building are insulated to at least R-8. [] Retum ducts in unconditioned attics or outside the building are insulated to at least R-4. Duct Construction: Electric Systems: Fireplaces: Service Water Heating: Circulating Hot Water Systems: Swimming Pools: Heating and Cooling Piping Insulation: Pro~ect Title: ANDERSON RESIDENCE Report date: 06/22/10 Data fiiename: Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runoute Heated Water Up to 1 ' Up to 1.25' 1.5' to 2.0" Over 2' Temperature (°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Range(OF) Insulation Thickness in Inches by Pipe Siz~s 2' Runouts 1" and Less 1.25" to 2.0' 2.5" to 4" Heating Systems Low Pressure/'remperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2,0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 NOTES TO FIELD: (Building Department Use Only) Project Title: ANDERSON RESIDENCE Report date: 06/22/10 Data fitename: Page 4 of 4 JUN 2 8 2010 BLDG. DEPT. TOWN OF SOUTHOLD EXISTING STREET ELEVATION PROPOSED STREET ELEVATION EXISTING HOUSE TO BE RENOVATED AND CONVERTED FROM 4 BR'S TO 5 BR'S NEW SIDING, ROOFING, INSULATION ELECTRICAL SERVICE AND PLUMBING EXISTING GARAGE TO BE REMOVED AND REPLACED W/2 STORY ADDTON NEW GARAGE WIIH BREEZEWAY EXISTING STONE STOOP FACING PECONIC BAY TO BE WIDENED Z ADDITIONS & O ALTERATIONS i{ T0 THE IELUS 1 RESIDENCE GREENPORT, NY i2875 BAY SHORE RD. ARCHITECT 123 CBIIRAL AVBqLi[ P.O.~X 316 ~, ~ 119~ ~E 631-4~ ~24 OWNE~ 152 ~ ~ ~ ~7~7~ BUILDING PERMIT APPLICATION FRANK W. UELLENDAHL, ARCHITECT P.O. BOX 316 GREENPORT, N~ YORK 11944 General Notes Design Criteria A- PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY SOLDER USED IN WA TER suPPLY SYSTEM CANNOT EXCEED 2/10 OF ~% LEAD. PLUMBING ALL PLUMlaNG wASl~- & WATER UNES NEED TESTINGBEFORE COVERING UNDERWRITERS CERTIFICATE RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE DO NOT PROCEED WITH FRAMING UNTIL SURVEY CERTIFICATION OF NAILING & CONNECTIX)NS REQUIRED. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF ~ . SOUTHOLD TOWN ZEA /' SOUTHOLDTOWN P~NN[NG BOARD SOu~HOLD ,u'/'~ Rbo~ccS ........ N.Y.S. DEC , . OD ZONE COMPLY WITH CHAPTER "46' FLOOD DAMAGE PREVENTION SOUTHOLD TOWN COOE. APPROVED AS NOTED FEE:'~ 7/0 -- NOTIFY BUILDING DEP.N~TMENT AT 765-1802 8 AM TO 4 !~1 FOR THE FOLLOWING INSPECTIONS: 1 FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2 ROUGH- FRAMING, STRAPPING, ELECTRICAL & CAULKING 3 INSULATION 4 FINAL - CONSTRUCTION & ELECTRICAL MUST BE COMPLETE FOR C.O. ALL CONSTRUOTION SN^U. MI~T THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. OCCUPANCYOR USEISUNLAWFUL WITHOUTCERTIFICATE OFOCCUPANCY ADDITIONS & GENERAL NOTES DESIGN CRITERIA: O ALTERATIONS ~ J~J TO THE 1. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN GROUND SNOW LOAD - 4-5 PSF. J~ (~ E~ ~ ~ E~ "~ ACCORDANCE WITH THE NEW YORK STATE UNIFORM UVING AREAS AND DECKS - 4.0 PSF. ! ~ BUILDING CODE, AND THE NEW YORK STATE ENERGY SLEEPING AREA - 30 PSF. i CONSERVATION CODE, AND LOCAL AUTHORITIES.WIND SPEED - 120 MPH JUN 2 8 2010 ~ : 2. ALL CONCRLq[ SHALL BE STONE AGGREGATE WITH A SEISI/IC DESIGN CATEGORY - B j ,,',, ', : j MINIMUM 28 DAY STRENGTH OF 3000 PSI WEATHERING - SEVERE ~ , ,:l I $. ALL LUMBER SHALL BE GP, AQE STAMPED DOUGLAS FIR- FROST LINE DEPTH - 56" j', i'', Iii'Il ,Il, ' J I LARCH STRUCTUP, AL GRADE t~2 OR BETTER. TERMITE - MODERATE TO HEAVY BLDG. DEPI. , i I i j ' j j - ,,,,,,,,, ,,:, , ,,,,,,, , ,,;,,!,!,,,,,,, , ,, ,,,I jljj ~ ELLIS DECAY - SUOHT TOWN OF SOUTHOLD ~ ~ ~ ~ ~ ~ ~ ~ Z 4.. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL ICE SHIELD UNDEREAYMENT REQUIRED - =S RESIDENCE STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL PANTmoNs, EXCEPT AS NOTED ON DRAWING. DESIGN IN ACCORDANCE WITH AMERICAN FOREST ~ GREENPORT, NY 5. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND PRODUCTS WOOD FRAME CONSTRUCTION MANUAL ' FLOOR BEAMS. SPACING NOT FO EXCEED 8.0 FT. FOR l&2- FAMILY HOUSE - PRESCRIPTIVE DESIGN METHOD ~ ~§ 2875 BAY SHORE RD. 6. ALL DIMENSIONS AND GRADE CONDITIONS TO BE~ ~ VERIfiED BY CONTRACTOR(S) PRIOR TO START OF WINDBORNE CONSTRUCTION AND ORDERIN~ OF MATERIALS. THIS FOUNDATION HAS BEEN DESIGNED FOR A SOIL ~ ARCHITECT BEARING CAPACll'f OF 11~0.~(2.)1SF AND GRADES DEBRIS PROTECTION SCHEDULE ~--: ......... ~ ~ ~= ~ LESS THAN 5%. CON1RACTOR SHALL VERIFY THAT i ~ FRANK U[LLE~tOAHL ~ P.O.BOX 516 CONCRETE SLABS TO BE COMPACTED TO 95% PRECUT WOOD STRUCTURAL PANELS WITH A THICKNESS RELATIVE DENSII'f. OF MIN 7/~6 INCH WITH 2-1/2 ~t6 ND SCREWS, EX[STING STRE T ELEVATION _~ GREENPORT, NY 119, SUPPORTED BY DOUBLE UPRIGHTS 9.0 iq- AND OVER THE GLAZED OPENINGS OF THE PROPOSED EXTENSION BY TRPLE UPRGHTS. ALL HEADERS TO BE ~ OWNERS MINIMUM OF 2-2x8 OR AS SHOWN ON DRAWING. - "! ~ ~ ~ ~ ~ ~ ~ ~ ~' x 8. PENETRATIoNsPROV1DE FIRESTOPPING AT ALL LEVEL WINDOW SCHEDULE ~"1 ' ~, 'l!J i ,: 'i' ~i ~°s~ELUSaiM ~DERS~ 152 WARREN S~EET I, ,I ,I i I , . BROOKLYN, NY 11201 ' ] I !j i!;; i J EL: 646-765-7084 CHIMNEYS, SKYLIGHTS, EXTERIOR DOORS, WlNDO~ , AND DECKS ETC.. WHITE EXTERIOR. UNFINISHED ON INSIDE, GRILLES PER PLANS = 10. DO NOT SCALE DRAWINGS. SCREENS ARE PROVIDED FOR ALL WINDOWS AND DOORS 11. DESIGN CONSULTANTS OR RECORD ARCHITECT- WINDOW HARDWARE: ESTATE COllECTION, FINISH: SATIN NICKEL ENGINEER ARE NOT RESPONSIBLE FOR THE ~: ~ ~ ~ INSPECTION, SUPERVISION, OR ADMINISTRATION OF Work Size Demdption Quantity ~ - - I, j i RESPONSIBIU1Y OF THE CONTRACTOR. B CLR24 CIRCULAR WINDOW - MUDROOM 1 ~ ~ ~ [ ~ ~ ~ ~ C 1~/3472 DOUBLE-HUNG - LR 3 j ~ 'i' ~ ~½~ ? ~ I' ~ 12. THIS DRAWING IS AN INSTRUMENT PREPARED TO D FWO54-68APLR OUTSWING PATIO DOOR - LR, MBR 2/ ~i ~ ~ ~ ~ ~ ~ FACILITATE CONSTRUCTION AND SHALL NOT BE E EWT2916 TRANSOM- LR 2 / ~ --- - == CONSTRUED AD A CONTRACT BEI/VEEN BUILDER AND F 1W2~052 DOUBLE-HUNG - LR, DR 5 OWNER, G ~2~072DOUBLE-HUNG- DEN ~ PROPOSED STREET ELEVATION 13. TRIS STRUCllJRE HAS BEEN DESIGNED IN G ~21072 GARAGE - 2X4 STUDS 3 ACCORDANCE WITH THE NEW YORK STATE ENERGY H EWO6OGOAPLR OUT.lNG PATIO DOOR - DEN CONSERVATION CODE. d lt~20$lO POWDER RW 1 14. ARCHITECT TO BE NOTIFIED IN WRITING OF ALL K C145 CASEMENT - KITCHEN 2 CHANGES PRIOR TO AND DURING CONSTRUCTION. L 1~/26310 DH - MBR CLOSET, LAUNDRY RM, AIIIC 4 EXISTING HOUSE TO BE RENOVATED AND CONVERTED FROM ~BR'STO 3BR'S M 1~/210410 MBR, BR2, BR3 11 DESIGNED AND SPECIFIED BY OTHERS, P 36'X80" ENTRY DOOR ~/glass 1 EXISTING GARAGE TO BE REMOVED AND REPLACEDW/ 2 STORY ADDITION 16, CONTRACTOR SHALL OBTAIN ALL PERMITS AND Q TI#1836 DOUBLE-HUNG- ATTIC DORMER 5 INSURANCE NECESSARY TO PROTECT THE ENGINEER R ~2'X14" BASEMENT - CUSTOM WOOD WINDOWS 6 NEW GARAGE WITH BREEZEWAY AND OWNER, EXISTING STONE STOOP FACING PECONIC BAY TO BE WIDENED 17. DO NOT BACKFILL AGAINST FOUNDATION WALLS UN~L FLOOR SYSTEM INSTALLATION tS COMPS. DRAWING SCHEDULE ~ ~ SCALE: NTS ~ Generol Notes A-3 EXISTING FOUNDAIION PEAN AND FLOOR PLANS A-4, FOUNDATION P[~ ~ o Desi~a Criterio ^-5 PROPOSED lsT ELOOR PLAN JUNE 23, 2010 ^-~ PROPOSED 2ND n_ODR Pm ~. A-7 CROSS SECTION A-A FRANK W. UELLENDAHL, ARCHITECT ?.0. BOX 316 CREENPORT, NEW YORK 11944 A-8 PROPOSED ELEVATIONS~ A - 1 A-9 CONNECTORS, CRITICAL PATH A-lO FRAMING NOTES, NAILING SCHEDULE ©~ O~;. NO PROP2ED 2ND FLOOR ADDITION ",, PROPOSE~) 'd-STORY GARAGE W/ BREEZEWAY DEMOLTION OF EXISTING ROOF ABOVE STOOP 159.74' 55.50' L PROPOSED 2ND FLOOR ADDITK 55' 75' SETBACK FROM BULKHEAD REMOVE EXT'O ROOF EXTEND STONE STOOP 55' 2$.2'STOOP ? BULKHEAD.-- REA RD i12 [ 2ND FL BALCONY R} BULKHEAI~ PROPOSED GARAGE 35.2' WITH -., GRAVEL DRIVEWAY ZONING CALCULATIONS LOT AREA = cQ. 15,217 SF = 100.00% !EXIST'G BLDG. COVERAGE ca. 1,255 SF = 8.23% ADDED BLDG. CO~RAGE = ca. 530 SF TOTAL BLDG. COVERAGE = ca. 1,783 SF = 11.72% ~X. BLDG. COVERAGE = co. 5,043 SF = 20.00% / PROPOSED SITE PLAN SCT,#: 1000-53-06-02 TOWN OF SOUTHOLD SUFFOLK COUNlt', NEW YORK ADDITIONS & ~ ALTERATIONS TO THE RESIDENCE NY 2875 BAY SHORE RD. ARCHITECT FRANK UELLEND,~E 123 CENiRN. ~ 119~ ~h 631-477 8624 OWNERS ROSEMARY EUJS ~ JIU ANDERSON 152 W~EN STRELFr BROOKLYN, NY 11201 EL: 646-765-7084 DATE: SC, ALE: 1/16" = 1'-0' SITE PLAN ~G. NO ~,.+ .'-,¢ 28' ,8,~2. ,2'-, ,/2' ~ iO :~ ALTERATIoNsADDITIONS & ':~- ~ ~ TO THE E IS ROOF --~. ~; ~ GREENPORT, NY -- ~ 2875 ~Y SHORE RD. ~ ~ ~ --m --~ ~ ~_ ~ ARCHIECT zLu ¥~ ' . ~'-¢ ~ ~'-~ ¥~' ~ ~ ~K UE~N~L . ..........~ ~~ - _ ~ ~ BR 2 ~ BR 1 I ~ ]23CE~A~NUE ~ P.O.~X 316 ~ ~1-477 ~24 - ~ ~ ~ ~ ~ OWNERS ~ ~ ] ~KL~, ~ 11201 - -" .... F .... ~ EXISTING 2ND FLOOR P~N ~ .~ EL: 6~-7~-70~ ~ S~B ON GRADE ABOVE ' BASEMENT ~ = ' ' ~r 500 SF , [ ~ ~ ~, S~EL COLUMN [ / ~ ~ ~ m'-o' ~ ~ DATE: 06/2~/2010 ~"~ ~ ~ ~ ~ ~ S~: 1/8"= f-O' ,,, ~ CONC. PATIO _ . ~ EXISTING ~FOUNDATION P~N ~ ~~ ~,~ ~ A FLOOR P~NS ~ CRAWL SPACE - ~IRELLIS L ~- _ . = EXISTING 1ST FLOOR P~N ~ ' ~ EXISTING FOUNDATON P~N -- - ~-. - - .... L A 959 SF .... m'~ ~'o' . s'r ~,259 SF FOUNDATION NOTES STRENGTH = 5000 PSI AT 28 DAY ASTM C-94 READY MIX CONCRETE. ALL FOOTINGS, FOUNDAFIONS, ETC SHALL REST ON UNDISTURBED SOIL. ALL FOOTINGS AND FOUNDATIONS SHALL BE FORMED. GARAGE FOUNDATION "x4" TREATED SiLL 5/8"X 12" ANCHOR DOLTS 4'-0" O.C. 8" POURED CONCRETE FOUNDATION WALL ON f-4"X 8" POURED GONG, FOOTING W/ KEYWAY SEE SEAL & TERMITE SHIELD 4" POURED CONCRETE SLAB WITH 6X6 10/10 WWM OVER COMPACTED FILL SE (2) #5 REBARS GARAGE SLAB ON GRADE 4" CONG. SLAB WITH 6X6 10/10 WWM OVER COMPACTED FILL 8", 5'-5" 9'-2" 17'-0" =i CRAWL SPACE FOUNDATION 5/4" SUBFLOOR, NAILED AND GLUED 2X8 FLOOR JOISTS @ 12" AND 16" O.C. R-19 FLOOR INSULATION 2'X6' TREATED SILL 2" CONCRETE DUST COAT ON 6 MIL POLY VAPOR BARRIER ON COMP· GRAVEL 8" POURED CONCRETE WALL I'-4" X 8" POURED CONCRETE FOOTING WITH 5-#4 REBARS - 3" ABOVE BOHOM OF FOOTING 5./8'X12" ANCHOR BOLTS @ 4'-0" O.C, 2" RIGID FOAM INSULATION ON INTERIOR WALL BITUMINOUS DAMPPROOFING TO GRADE SILL SEAL TERMITE SHIELD PERIMETER DRAINAGE IN GRAVEL BED CONNECTED TO DRYWELLS BILCO DOOR TO BE REPLACED 'VENT t6X8 (lYP) ~9'9" --~-~).. 2X10 a;Der DER i II STEPPED FOUNDATION. IN AREA OF STAIR PREPARE 52" X 52" OPENING FOR ACCESS TO CRAWL ~ 9L9'' i · X' 6X6 TRT'D POST O~ i x-- CONCRETE FOOTtN~ ~ 2'-O"X2'O'X~_L_ CRAWL SPACE ' UP PROPOSED ~" DIA STEEL COLUMN ON j 2'-0" X 2'-0" X f-O" CONCRETE FOOllNG BASEMENT ~111 ~11 [ ~ I~ ILL__ LIJ ill-- III IH Ill ~ ~X8 C.d. ~ 16' O.C. III SISTERED ~ NEW 2Xg's ~ERE EXT O JOISTS ARE EXPOSED TO ROT AT THE SILL P~TE PROPOSED STLEL COLUMN ON F~ 2'-0" X 2'-0" X 1'-0" CONCR~E FOOTING I! LJ J 28'-10" 27' 6" CRAWL SPACE iNSTALL 2" RAT SLAB 5'0' . 20' 6" 6'-2" 12'-10" ,, LEGEND ~ EXT'G CONCRETE WALL ~ NEW CONCRETE WALL ~ · WALL ABOVE ADDITIONS & ALTERATIONS TO THE PROPOSED OIL TANK BUMP PUMP BOILER PLATFORM COLUMN EXT'G 2XB C.J. ~ 16" O.C. EXT'G FOOTING 9'-10" FOUNDATION PLAN SCALE: 5/16" = 1'-0" ELLIS RESIDENCE GREENPORT, NY 2875 BAY SHORE RD. ARCHITECT FRANK UELLE~tDAHL 125 CENTI~ A~NUE P,O.BOX 516 GREE}IPO~RT, NY 1194~ l[L: 651-477 8624 OWNERS ROSEI~ARY ELLIS 152 WARREN STREET NT 11~1 DATE: 06/23/2010 SCAE: ~/16" = f-o" PROPOSED FOUNDATION PLAN Di~G. NO SIDING 1/2" CDX PL~OOD R-21 INSULATION EXISTING 2X4 STUD CONS1RUCTION THIS AREA EXTERIOR WALL DETAIL SCALE: 3/4" = ILO" 1W21072 = , 8' 2" 16¥4" 8'-2' Post NEW 2X6 STUD - CONSTRUCTION THIS AREA 1/ DRYWALL (17P.) AND 1/2" PLY PLUS BEADBOARD IN SELECT AREAS EXT 2X4 STUD EXT'G 5/(' TAG SHEATHING 1,5"X2" BLOCK SCREWED INTO EXT'G STUD R-15 HIGH DENSI~ BA~ING INSULATION R-13 2" RIGID INSULATION STEP UP ~ 49'_4' 20'-6" 2?-2 t/2~ 7'-7' _ ~ 4 ~' ' 1(-10" :OUTDOOR SHOWER 'i DRA~ND 1~21052 ~21052 HEADER: (2) 2X6 28'-10" 9'-5" 9'-6" BILCO DOOR '~ DR HEADER: (2) 2X6 (IYP.) ~l~ 16'-0" 4 5'-11" I DEN OWNERS' CLOSET 560 SF 4 sheNes 016" BOOK SHELVES UP Powder Room 7' 7' !' 2 V~i 12'-5 1/2' 1~21052 1W21052 ~E~£R: (2) 2X6 (TYP.) WINDOW SEAT EXT'G WOOD FIREPLACE DOORS TO BE INSTALLED 2XlO SISERED TO E)(I'6 2X10 SISTERED TO EXT'G CJ. LR ~ ADDITIONS & ALTERATIONS TO THE ELLIS RESIDENCE GREENPORT, NY 2875 BAY SHORE RD. ARCHITECT FRANK BEU.ENBAHL 123 CENTR~ AV~3~UE P,O.BOX 316 GREBIPO~', ~ 11944 TEL: 631-477 8624 OWNERS ROSEl, lfftf B. US & ~IW ,~iDBRSON 152 WARREN S]REET BROOKLYN, NY 11201 TED 646-765-7084 GARAGE 425 SF 2X8 C.J. ~ 16" O.C. WITH BRIDGING iT-O" CURB WOOD BARN DOOR 8'-6"W X8' O"H \ BRICK APRON / \ / \ / \ / LEGZ D NEW WALL EXISTING WALL DEMOLITION FOUNTAIN 5.5'XB.B" LSL HEADER = ~-- KITCHEN BRICK STEP FWO608OAPLR [] ' 8'-6' BRICK PATIO GRADE 2" BELOW PATIO (2) 2X10 SISTERED TO EXT'G C.J. EXT'O 2X10 C,J. @ 16" O.C. EXT'G 2XlO C.J. @ 16" O.C. REF. t BRICK L~NDINC II 4'-5" ~8", ~5472 939 SF EXISTING HABITABLE FLOOR AREA: 959 SF ADDED HABITABLE FLOOR AREA: 575SFSF GARAGE (NON-HABITABALE FA): ~25 SF TOTAL FLOOR AREA: 1,759 SF TOTAL ADDED FLOOR AREA:800 I ST FLOOR PLAN SCALE: 3/1¢ = f-O" DATE: 06/23/2010 SCALE 3/t6"= iLO" PROPOSED 1ST FLOOR PLAN D~6. N~E A-5 FLAT TO ROOF LEGEND ~ NEW WALL EXISTING WALL DEMOLITION 12'_4~ 49' 4" 20'-6" 2'-2 1/2" T-7" 9'-5" 7' 7" ,, 5'-5" ._ 4' 2" , 14'-10" 4 1_/_2" 12'-5 1/2" 2'-2 THIS WINDOW QUALIFIES I~ i AS 2ND MEANS OF ECRESSJ ~ TW210410 TW210410 HEADER: (2) 2X6 (Ff'P.) FUlL SIZE 54~75" ~ BR 3 iCLG,HGT: §'-0" QUEEN I 2868 (;loss Pocket LADNDRy CLUB;T! 8'-I' HEADER: (2) 2X6 TW210410 ~26310 T-11 1/2" t 4'-0 ~ I lW21046 ~21046 TW21046 lW21046 HEADER: (2) 2X6 WINDOW SEAT PTC ,r EXT'G 2X8 C.J. ¢ 16" O.C. , BR 2 CL(;.HGT: 8'-0" %- BATH 1 4~ CLG.HI;I: %~ rec'd Wed. Cob. I 4'-6" ATDC TO lO REM~N rod+2 shelves @16' QUEEN i il HALL J !CLG.N~: EXf'C 2XB C.J. ~ 16" O.C. d DM MBR 2868 CLG.~T: 8'-0" BATH rod+2 shelves '~'~c" CLOSET 5'-6~ Ct(;.H(;l: 8'-¢ __ HEADER: (2) 2×6 ,!8'+ 0-9 ~ 11-10 3/4 i I I · ........... · ROOF i EXISTING HABITABLE FLOOR AREA: 875 SF ADDED HABITABLE FLOOR AREA: 575SFSF TOTAL FLOOR AREA: 1,250 SF TOTAL ADDD FLOOR AREA: 375 2ND FLOOR PLAN SCALE: 3/16" = f-O" ADDITIONS & ALTERATIONS ELLIS, RESIDENCE GREENPORT, 2875 BAY SHORE ARCHITECT FRANK UELLENDAHL 123 CENiP~ A~ENUE P.O.BOX 316 GR1]~IPORI, NY 11944 TEL: 631-477 8624 OWNERS ROS[tW~h' ELUS A JIW ~DBRSON 152 W,~u'd SIRED BROOKLYN, NY H201 TED 646-765-7084 DATE: 06/2,3/2010 $~E: 3/16"= f-o' PROPOSED 2ND FLOOR PLAN DWG. NAME A-6 D~G. NO RIDGE VENT EACH RAFTER 1-3/4'X11-7/8' LVL RIDGE POST ROOF RA~ERS @16" O,C. PL~VOOD C.J. 016' O.C. INSULATION FASCIA BOARD 2X~TO~P~ (2) 2X6 HEADER I L 2X6 H~EADER ;IW/ R-21 INSULATION I J I I I BEDROOM 3 L C.J. 016' O.C, W/BRIDGING ,' DEN SUBSILL I ~ F.J. 0 16" O.C. i w/R-19 INSULATION L5"X5.5" LSL HEADER VENT CRAWL SPACE 6x6 TRT'D POST ON I I I I RIGID INSULATION I I 17' 4" '~CONT. PERIMETER DRAINAGE - ~ CONNECTED TO DRYWELL = ' ~ EXT'6 BASi~ENT SLA~ B-EYO~D Y- -J 30'-4" . ROOF / CEILING CONT. RIDGE VENT 30 YR ARCH'L GRADE ROOF SHINGLE ON 15 LBS FELT IN 120MPH REGION: 6 MILS PER SHINGLE REQU'D FOLLOW MARUFACTORER S GUIDELINES FOR INSTALLATION 5/8" CDX PLY~g)OD SHEATI41NG 2X6 ROOF RAFTERS 0 16' O.C. R-~8 INSULATION ON 2X12 C.J. 0 16'0.C. / 3/4' SUBFL®R 1/2" GYPSUM BOARD 12" continuous VENTED ROOF OVERHANG il/2" BEADBOARD SOFFITS (1YP.) i WALL : 1/2" GYPSUM BOARD R-21 HIGH DENSI~ BATTING INSULATION 2"X6" STUDS 0 16" O.C. 1/2" CDX PL~OOD 172' RIGID INSULATED SHEATHING IN LIEU OF SIDING FELT BEVELLED RED CEDAR SIDING 4-1/2' EXPOSURE, ADDITIONS & ALTERATIONS TO THE :i ELLIS I RESIDENCE ~ GREENPORT NY 2875 BAY SHORE RD. ARCHITECT FRANK UELLENDAHL 125 CE~ AVENUE PRE-STAINED AND BACKPRIMED 2ND FLOOR HARDWOOD FLOR / CERAMIC TILES 3/4" TAG SUBFLOOR, NAILED & GLUED !XIO CJ. 0 16" O.C W/BRIDGING R-19 INSULATION ,]RAWL SPACE FOUNDATION !3/4' SUBFLOOR, NAILED AND GLU.E,D 2X8 FLOOR JOISTS ~ 12" AND 16 O.C. iR-19 FLOOR INSULATION ~X6" TREATED SILL '2" CONCRL-fE DUST COAT ON 6 MIL POLY VAPOR BARRIER ON COMP. GRAVEL 8" POURED CONCRETE WALL f-(' X 8" POURED CONCRETE FOOTING WITH 3-#4 REBARS - ~" ABOVE BOTTOM OF FOOTING 5/8'X12" ANCHOR BOLTS 0 4'-0" ~.C. 2" RIGID FOAM INSULABON ON INTERIOR WALL BITUMINOUS BAMPPROOFING TO GRADE SILL SEAL TERMITE SHIELD P.O,BOX 316 NY 11944 let: 631-477 8624 OWNERS & JIW ~DERSON 152 ~ARREN STREET NY 11201 EL: 646-765-7084 TO DR~ELLS :PERIMETER DRAINAGE/N GRAVEL BED CONNECTED DATE 06/23/2010 sc~: 1/4': f-o' SECTION A-A Dwo. A-7 PROPOSED EAST ELEVATION 55'-4" ADDITIONS & ALTERATIONS Iii ELLIS RESIDENCE ~ CREENPORT, NY 2875 BAY SHORE RD. ARCHITECT FP, ANK UEIZENDANL 123 CEN1RAL A~NUE P.O.BOX 516 ~EENPO~, NY 11944 TEI~ 6:$1-477 8624 PROPOSED NORTH ELEVATION 71'-4" O~NERS ROSEI~ARY ELUS & JIM ~NI)t[RSON 152 W~R£N Sil~ BROOKLYN, NY 11201 TEl: 646-765-7084 PROPOSED WEST ELEVATION T PROPOSED SOUTH ELEVATION DALE: SCAE: 1/8' = f-O' PROPOSED ELEVATIONS DWE NAI~F A-8 DVP. NO ~m" ADDITIONS & O ALTERATIONS It~ TO THE < 24" > ~_ ICE SHIELD UND.ERLAYMENT REQUIRED - 24 FROM EDGE CLIPHURRICANE TYPICAL. ~ ~ . i _ I Ii I I I I I ~ GREENPORT,NY " 'I ' , , , , ~ t-1/4" 20 GAGE S~AP / / ~PRO~DE 8d COMMON ~ ~ JACK POST I~R4~D~'O~TALL EACH END - TYP. ARCHITECT RAF~R TO STUD. -- / / SHEATHING' TYPICAL ALL RAFTERS / / ~ ~ UE~L 5 - Bd NAILS EACH END / ~ ~2~ CE~ A~NUE OF 1-1/4" 20 GAGE S~ / 6~-477 ~24 APA RATED PLYWOOD ~ GREN~, ~ 1~ 1-~/4" 20 GAGE STRAP w/ 5 - Bd NAILS ~8" D.C. ~1-1/4" 20 GAGE S~AP W/ EACH END - Typ. TO EX.ND TO -- /5 - Bd NAILS ~ EACH ]STOL. 2ND FLOOR ~o~ oF TOP PLATE /S~D - EACH END - TYP. ~ : ~ 0WNE~ /( ~, ~' o.~, ) I ~ ~ ~ ~ ~s . ~ ~ ~ · ~KL~, ~ 1120t PLYWOOD SHEATHING ~AP + NAIL S~AP~ 1 1/4" ~DE - 20 GAGE ( ~ - 4d NAILS ) ~ ~METAL S~AP ~ 48" OC. 'p. AROUND SILL PLATE ~ /5 - Bd COMMON NAILS ~ST FLOOR ~ ~.o~ ~"°~ .=~_ -- -- - /Sd NAILS ~ 4" O.C. (2) ~ ~[~s- - -- ~ ALUMINUM TERMITE FLASHING 2" RIGID INSULATION ~ ~ ~5/8" X 12" A.D. ~ 48" OC. , C~WLSPACE ~- P.C. FOUNDATION ~ ~BI~MINOUS DAMPPROOFING ON W/ 1'-4" X 8' CONT. FTG, ) ]/2" CEMENT PARGING (3) ~4 ~EB~S~ ~ ~ ~ ~PERtME~R DRAINAGE ' ~E: ~ ~CONNECTED TO DRY~LLS SECTION ELEVATION ~ ~. ~E HOk~ DOW~ + SHEAR CO~[CIIO~ CRITICAk CATH ~~.~0 HURRICANE CLIP TYPICAL. i DOOR OPENINGS Z ADDITIONS & FRAIvlING NOTES NAILING SCHEDULE - WFCM m O ALIERATIONS I Joint Description j Nail Sizes I Nell Spacing I ~ TO THE I. A~ F~ING LUWBER S~L BE G~E ST~PED 8d ~r DOUG~ ~R-~RCH STRUC~ G~E No. 2 OR X ~a~er J~.TpR P~Je []~-g~Jled) ~ ~all HeighJ: ]0 fl, Spacing ~6' O.C. (Table ~.3A) 4~ ~r lo,s~ B~ER. ~e~ng ~o]s~ ~o Parallel ~os~f ~Fap~-noileq/., n eac~ ~ap 2. ~IN.ALL SH~ING THICKNESS TO OR BE ~ APA NOTED.~TED' ~POSURE ~. 5/8' Dlacmng ~pIIq[ bemng ~e~°lS~otO.R~f~er,~Face-.ga~ked/Ko,er Laps OV~[ u~-nalJeoJ ~amuons~vace-nmma}~ 2 ~d n/~a each per each beend~aP Rim ~ard to Rafter (End-noned) 2 - 16d ~ch end 3. ~ SUB~OORING TO BE ~A ~TED S~RD-I-~R, EXPOSURE l, 3/4' WIN. ~KNESS. ~L E~ES OF ¢~' ~":RESIDENCE PL~D TO BE SB ON SOUD BL~KING. GLUE ~D N~L PL~D SUBFL~R TO FLOR dOl~S. ~oP ~]a~e to,TpR Plal~. (Face, nailed).. ,, 2 - 1~ .. ,~r f~t., mp maJes at )memec~mns, Ltace-na~ieo} 4 - jom s- ac, s,oe GREENPORT, NY ~TH ~UBLE UPRIG~S. ~D O~R ~ITH neoaer to neoner Lrace-nmma) 1Bd lB' o.c. along edges 2875 ~Y SHORE RD. ~IPLE UPRI~TS. ~ H~ERS S~ BE A Top or ~ttom Plole to Stud (End-nailed) 2 - 16d ~r ~x~ stud MINIDUM OF 2-2X8 OR ~ SHO~ ON D~NG.2 2- ]~ 'r zxo stud - ~r 2x8 stud~ ARCHITECT 5. SOUD BLOCKING S~ BE PROVIDED FOR ~ JOISTS ~D ~0~ B~S AS PER N.Y.S_.CODE OR ~ NOrD Botlom Plate to Ho~ Joi~,Bondj~st,E~joist or BI,king (F~e-nailed) 2 - 16d per foot ~ ~ UE~L 8'-0' ~ O.C. MIN. PRO,DE SPACE FOR AIR ~ t23 C~ A~UE 2 CIRCU~TION IN RO0~. ~ Lt~?; ~ q.,,~,. ~; ~ P.O.~X 316 ~J ~, ~ 119~ 6. ~UBLE ~MING ~OUND ~L OPENINGS ( s~lights, ~oj~t.to ~11/.T~p,~lote gT ~irder (T~-neiled) 4 - 8d per.joist. ~ EL 631-~77 ~24 ~nagmg m dms[ ~(~-nm~eaj 2 - 8d eacn eno stairs etc.) OR AS NOTED ON D~WlN~S. ~cF~ng ~o ~jsl t~-~gilca}, .... , 2 - 8d each end >m or/ap,rime L me~noneo} ~ - 1~ each bilk ~J OWNERS 7. DOUBLE UP ~1~ UNDER ~L POSTS AND P~LEL Dlocmn~[O~e~ger~rip.LeagertO ~a~mtFac~-nail~u~T, nmJeo)., 3 - 16d per~Ch'jmstJ°~st P~TffIONS OR AS NOTED ON D~WI~S. ~o~st on m 3 - 8d ~J ~and Jois~ ~o ~q~st (E~d-~Diipd) 3 - 1~ per joist 8. ALL FLUSH W~D CONNEC~ONS S~ BE F~TENED ~and Jois~ ~o ~ or mp ma~e (Toe-no ed) 2 - 16d per ~j ~KL~, ~ 11201 W~ ~TED ~V~IZED M~ CONNECTORS ~~.~-' ...'-~~J =~6_765_7~ ~CO' OR ~PROVED EQU~. ;~'~,~ J, Structural Panels 8d 4' o.c. ,rime[er zo~ other 6 D.c. edges of 9. N~UNG SCHEDULE SHA~ BE ~ PER THE N.Y.S. ~nel, 12' D.c. interior~ ~,~ BUILDING CODE ~ A MINIMUM. ~ 2X6 S~DS DiagonaJ B~r~ Sheathing. of panel ~ EX,PlOP ~ILS S~ BE ~V~IZED. 1 x 10 or ~ider ~ - 8d per support o.c. ~OR ~ES ~D 6 d , 12" o.c. j 17, I~ERMED~. Gypsum Well,rd ~ edge / 10" field 11. ~L I~ERIOR ~D E~ERIOR FINISHES, ~SHIN8 "~'~ ~' ~D WA~RP~N~ S~LL BE BY A~HITEOT. St~clural Panels 8d 6' edge / 12' field 12. A~ ROOF ~RS S~ BE A~ACHED TO THE P~TE ~be~ard Panels AND STUD WI~ ~WlZEO HURRICANE ~E 7 6' CONNECTORS BY ~ECO" OR APPRO~D EQUAL. FOR 25 ~2' 8d ~" edge 6' field CU~S ~1 ~k[ ¢[~1~ dOISl 10 GI~[~ Gypsum ~ollboord 5d 7~ ~e ~ 10~ fie~ ¢0~[¢110RS, ~rd~ord 8d 6, edge ~12' Del~ 13. ALL PRE-E~INEERED LUMBER SHALL BE gEO~g Diagonal ~ard Sheathi~ PRODUCTS OR EQU~. ~L JOISTS, GIRDERS ~D 1 x 10 or ~Jder ~- 8d per sup~d H~DERS SHALL HA~ B~ING STI~ENERS IN~ALLED = ,~ , ~. ~. ~ PER ~UFAC~RERS RECOmmENDATIONS. WEB ~J J I ~ J S3FFENERS S~ BE REQUIRED AT ~L LO~ ~_,.~ Structural Panels ~l B~ING POI~ AT A ~INIMU~. A SINGLE ~~R greater1" or le~ 1" 8d 6"6,~gee~ge ~/o~",.fi¢~d L~ RI~ JOIST S~ BE REQUIRED AT than t~ ~S~: ~: ~/23/2~S010 PERI~ERS. H~DLING, STOOGE, ~D E~C~ON OF RECOMMENDATIONS. ~ x 6".or 1" x 8' 2 - 8d per suppo~ , x 10 or,der ~-Sd per support ~1 Noi,~ Schedu,e 14. ~L MULTIP~ LVL PRODUC~ TO ~ 2 ROWS OF 1/2' DIA. .Nailing requirements are ba~d on wall sheathing nailed 6' on-center at the ~neJ edqe. If ~aJl shea[hinq ~s nailed G~V~IZED ~CHINE BOLTS ~ 12' O.C.. b on-center a~ the ~nel edge to obtain h~her shear capaciUes nailing requ,remen[s Tar structural members shall ~J be daub ed, or alternate connectors, such as shear plates sha~ ~ used [o maintain the I~d path. When walt shea[hino is continuous over connected members, the tabulated numar of nails sha,,~ permitted to ~ ~J be reduced to 1 - ~d nail per foot. ~ ~ DWG. NO A - 10 J