HomeMy WebLinkAbout34775-ZTown of Southold Annex
54375 Main Road
Southold, New York 11971
5/4/2011
CERTIFICATE OF OCCUPANCY
No: 34942
Date: 5/4/2011
THIS CERTIHES that the building
Location of Property:
SCTM #: 473889
Subdivision:
ACCESSORY GARAGE
30653 CR 48, Peconic, NY 11958,
Sec/Block/Lot: 73.-4-5
Filed Map No.
conforms substantially to the Application for Building Permit heretofore
6/15/2009 pursuant to which Building Permit No. 34775
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
Lot No.
filed in this officed dated
dated 6/15/2009
nonhabitable accessory garage with 1/2 bath.
The certificate is issued to
Greene, Andrew & Greene, Elizabeth
(OWNER)
of the aforesaid building.
SUI01~OLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED 5/4/11
10-02-0014 6/23/05
2051678 1/23/06
Mike Jacobi
~' Aul~rized Signature
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
(THIS
BUILDING PERMIT
PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO.
34775 Z Date JUNE 15, 2009
Permission is
hereby granted to:
ANDREW & ELIZABETH GREENE
30653 CR 48
PECONIC,NY 11958
i ABD. £ ALT. TO k2,~ EXISTING DW? & CONSTRUCTION OF A NEW
ACCESSORY GARAGE. 2 C/O'S REQUIRED SIMULTANIOUSLY.REPLACES EXP.BP# 33002
at premises located at 30653 CR 48
County Tax Map No. 473889 Section 073
pursuant to application dated JUNE
Building Inspector to expire on DECEMBER
PECONIC
Block 0004 Lot No. 005
15, 2009 and approved by the
15, 2010.
Fee $ 593.40
Authorized Signature
ORIGINAL
Rev. 5/8/02
(THIS
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
PERMIT MUST BE KEPT ON THE PREMN
THE WORK AUTHORI;;ED)
FULL
PERMIT NO. Z Date
Permission is her~ g
1220 SI
NY 11 52
for :
ADDITION & ALTERATIONS TO AN EXISTING DWELLING &
NEW ACCESSORY
C/OS REQUi SIMULTANIOUSLY.
OF A
REPLACES BP # 30680
at premises located at 30653 CR 48
PECONIC
County Tax Map No. 473889 Section 073 Block 0004 Lot No. 005
pursuant to application dated APRIL
26, 2007 and approved by the
Building Inspector to expire on NOVEMBER
Fee $
4, 2008.
Authorized Signature
ORIGINAL
Rev. 5/8/02
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 30680 Z
Date OCTOBER 4, 2004
Permission is hereby granted to:
ANDREW J GREENE
1220 SIGSBEE ROAD
MATTITUCK,NY 11952
for :
ADDITIONS AND ALTER3tTIONS TO AN EXISTING DWELLING AND CONSTRUCTION
OF A NEW ACCESSORY GARAGE AS APPLIED FOR. 2 COS REQUIRED SIMULTANIOUSLY
at premises located at 30653 CR 48 PECONIC
County Tax Map No. 473889 Section 073 Block 0004 Lot No. 005
pursuant to application dated SEPTEMBER 22, 2004 and approved by the
Building Inspector to expire on APRIL 4, 2006.
Fee $ 593.40~//~/~
ORIGINAL
Rev. 5/8/02
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUpANcy
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual naturat or
topographic features.
2. Final Approval from Health Dept. of water supply and sewemgn-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00,
Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Date.
New Construction: Old or Pre-existing Building: (check one)
Location of Property: ~'~)[.g'?~'~'~) C~ ~'-i-~ ~~ ~
House No. Strut Hamlet
OwnerorOwnersofPrope~y: ~f~_1 ~~ ~¢ ~]i~~
Suffolk County Tax Map No l000, S~tion ~ ' Bl~k ~ ~t ~
Subdivision ~t:
P~t No. ~ ~ Date of Pemit.
Health Dept. Approval:
Planning Board Approval:
Filed Map.
Applicant:
Underwriters Approval:
Request for: Temporary Certificate
Fee Submitted: $ ~"~ ~
_ Final Certificate:
(check one)
Applicant Signature
r
BY THIS CERTIFICATE OF COMPLIANCE THE
NEW YORK BOARD OF FIRE UNDERWRITERS
BUREAU OF ELECTRICITY
40 FULTON STREET ~ NEW YORK, NY 10038
CERTIFIES THAT
Upon the application of upon premises owned by
PAUL R. BURNS ANDREW GREENE
P.O. BOX 1061 30653 RT 48
SOUTHOLD, NY 11971-0932, PECON lC, NY 11958
30653 RT 48 PECONIC, NY 11958
Located
at
Application Number: 2051678 Certificate Number: 2051678
Section: Block: Lot: Building Permit: BDC: ns11
Described as a Residential 1200-1799 square lt. occupancy, wherein the premises electrical system consisting of
electrical devices and wiring, described below, located in/on the premises at:
First Floor, Second Floor, garage, Detached Garage, Outside,
A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed
herein, was conducted in accordance with the requirements of the applicable code and/or standard
promulgated by the State of New York, Department of State Code Enforcement and Administration, or other
authority having jurisdiction, and found to be in compliance therewith on the 23rd Day of January, 2006.
Name QTY Rathe Rating Circuit Type
Alarm and Emergency Equipment
Sensor 1 0 Carbon Monoxide
Sensor 3 0 Smoke
Appliances and Accessories
Furnace 2 0 Gas
Air Conditioner I 0 24.000 BTU
Air Conditioner I 0 30.000 BTU
Panels
Wiring and Devices
Outlet 11 0 Fixture
Fixture 11 0 Incandescent
Outlet 34 0 General Purpose
Receptacle 22 0 General Purpose
Switch 16 0 General Purpose
Disconnect 2 0 60 amp Air Conditioner
Receptacle 5 0 GFCI seal
Continued onNext Page 1 of 2
This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.
BY THIS CERTIFICATE OF COMPLIANCE THE
NEW YORK BOARD OF FIRE UNDERWRITERS
BUREAU Of ELECTRICITY
40 FULTON STREET ~ NEW YORK, NY 10038
CERTIFIES THAT
Upon the application of upon premises owned by
PAUL R. BURNS ANDREW GREENE
P.O. BOX 1061 30653 RT 48
SOUTHOLD, NY 11971-0932, PECONIC, NY 11958
30653 Rt 48 PECONIC, NY 11958
Located at
2051678
Application Number: Certificate Number: 2051678
Section: Block: Lot: Building
ns1
1
Permit:
BDC:
Described as a occupancy, wherein the premises electrical system consisting of
Residential
1200-1799
R.
square
electrical devices and wiring, described below, located in/on the premises at:
First Floor, Second Floor, garage, Detached Garage, Outside,
A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed
herein, was conducted in accordance with the requirements of the applicable code and/or standard
promulgated by the State of New York, Department of State Code Enforcement and Administration, or other
authority having jurisdiction, and found to be in compliance therewith on the 23rd Day of January, 2006.
Name QTY Rate Rating Circuit Type
seal
2 of 2
This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.
Town Hall Annex
54375 Main Road
P.O. Box 1179
Soul,old, New York 11971-0959
Telephone (631 } 765-1802
Fax (631 ) 765-9502
BUILDING DEPARTMENT
TOWN OF SOUTHOI,r~
CERTIFICATION
Owner:
(Please print)
Plumbcr: ,/r~ ~ &
(Please print)
Date:
I certify that the solder used in the watcr supply system contains less than 2110 of 1%
lead.
Sworn to before me this ~J4~'~
(P Signature)
day of c'~ C664~. , 20
Notary Public,
LINDA J COOPER
NOTARY PUBLIC, State of New York
NO. 01CO4822563, Suffolk Coun/~/
Term Expires December 31, 20..[~c-'
County
INSPECTION
[ ]FOUNDATION 1ST [ ]ROUGH PLBG.
[ ]FOUNDATION 2ND [ ]INSULATION
FRAMING / STRAPPING FINAL
[ ] FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONS'IllUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS: ~ ~ ~
DATE )~--/~"- ~ 7 INSPECTOR~ ~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION ¶ST
] FOUNDATION 2ND
[ ] FRAMING / STRAPPING
RO~-'PLBG.
[ ]w~i~ULATION
FINAL
[ ] FIREPLACE & CHIMNEY [ ] fiRE SAFETY INSPECTION
[ ] F~ ~ COWTUUCT~_ [ ] ~E REmTANT FENETRAT.)N
REMARKS: ~~ ~-4~--~ //~,-~ ,~,~ ,
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ]INSULATION
FRAMING / STRAPPING ,~ FINAL ,/~
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ]FIREIIESISTANTCOflSTRUC'/I~ [ ] FIRE RESISTANT PENETRATION
REMARKS: ~/~
Elizabeth Thompson, Architect
250 Mercer St., Suite B806
New Y0~; NY 100t2..
www. elizabeththompsonarchitect.com
tel. 212-614-7180
April 25,2011
Southold Building Dept.
Southold Town Hall Annex
P.O. Box 1179
Southold NY 11971
Re: Permit #34775Z
Andrew & Elizabeth Greene
Lot # 1000-73-04-05
T° ~the Building :DePartment,
As Architect of record for this completed project, I certify that all phases of the construction,
including the foundation, framing, strapping, plumbing & pressure test, and insulation were done
according to all applicable building codes.
Sincerely,
Elizabeth Thompson, R.A.
oD
BUILDING ~PARTMENT
TOWN HALE
SOUTHOLD, NY 11971
TEL: 765-1802
/
Examined Io/q ,20 4
Approved I tO/ t.{ ,20~
Disapproved
SEP 2 2 20O4
PERMIT NO. ~¢~D:~
t5 UR,DINLi P~ICAVll I AIq%,ICA'flON CHECICLIS'
Do you ~v~ or n~d ~e follows, be%re applyin~
Bo~d of Heal~ ~
3 sets of Building Ham ~
S~cy. ~
Chcck ~
Septic Fo~
N.Y.S.D.E.C~
Trustees
Contact:
Building Inspector
Mail to:
Phone:
APPLICATION FOR BUILDING PERMIT
Date ~FT- ~ ,2004'
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings (~n·premises, r~lationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection througho.ut'the work.
e. No building shall be occupied or used in whole or in part for any purpose what-so, ever until a Certificate of Occupan
is issued by the Building Inspector.
APPLICATION IS HEREBY MADE to the Building. Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of $outhold, Suffolk~County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to cohaply with all applicable laws, ordinan6?s, building code,~housing code, and regulations, and to admit
authorized inspectors on premises and in building for neees, sary inspections, d5~ ~~..._.~.,[ v..~...~__-
(Signature of applicant or narde, if a corporation)
Z~'o Iq~e.r..~ qT. ~,X6, lg-'go~
(Malling address of applicant)
State whether aPplicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Pr ~C.~4 tT~ r_-T-
Nameofownerofpi'emises ~l:,r6e,~,x/ q ~t47..~e~H
(as on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License
Electricians License No. "
Other Trade's License No.
1. Location of land on which proposed work will be done:
2~o66~ Loo~-r-r ~.4~, "'
House Number Street
Hamlet
County Tax Map No, 1000 Section
Subdivision
(Name)
Block q
Filed Map No.
Lot
State existing use and occupancy of premises and intended use and occupancy of proposed constttlcti~:
a. Existing use and occupancy ~'ol~6t.~ Ftl*tlt.~
b. Intended use and occupancy_ %t~t,,.~,~;
Nature of work (check which applicable): New Building X
Repair. Removal Demolition
i. Estimated Cost 7~'IooO
If dwelling, number of dwelling units
if garage number of cars ~
Fee
Addition Alteration
Other Work
(Description)
(to be paid on filing this application)
Number of dwelling units on each floor -----'
If business, commercial or mixed occupancy, specify nature and extent of each type of use. ~
Dimensions of existing structures, if any: Front__ _ Rear . - Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front
De, pth Height. Number of Stories
Dimensions of entire new construction: Front '~& ' Rear
Height ~.--~ ~ Number of Stories ~
Size of lot: Front 15o' Rear [~ '
Depth
0. Date of Purchase
Name of Former Owner
Rear
Depth Gq' I
1. Zone or use district in which premises are situated
2. Does proposed construction violate any zoning law, ordinance or regulation:
3. Wilt lot be re-graded ~O
4. ames of Owner otpremtses
Name of Contractor ff'¢ltlt~'L~-.~o~
Will excess fill be removed from premises: YES
Address a. to Phone No. bSt'2~
Ad&ess~Phone No gl~ - ~14 - 7/go
Ad.ess ~m C~ ~, ~Phone No.
5. Is this property within 100 f~eet of a tidal wetland? *YES NO fi(
· rF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED
6. Provide survey, to scale, with accurate foundation plan and distances to property lines.
7, If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
TATE OF NEW YORK)
SS:
:OUNTY OF )
being duly swom, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
;)He is the
(Contractor, Agent, Corporate Officer, etc.)
fsaid owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
mt all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
~rformed in the manner set forth in the application filed therewith.
worn to before me this
TOWN OF SOUTHOLD P~'0PERTY RECORD CARD
OWNER
.FORMER OWNER
LES. S~S.
LAND
/~o
'illoble
¢oodlond
~eadowlond
louse Plot
ota I
IMP.
TOTAL
N
VILLAGE
E
W
FARM COMM.
DATE
z/~P O o /p' e ~.
3/,
I ,
FRONTAGE ON wATER
CB. MICS.
Mkt.
/alue
REMARKS
,
I/ ~/
/ / G'I ,z -,J T~ L ,; / ; ~
~ '
DEPTH
BULKHEAD
DIST. J SUB. LOT
ACR.
TYPE OF BUILDING
FORM NO. 3
NOTICE OF DISAPPROVAL
DATE: June 30, 2008
AMENDED: March 20, 2009
TO:
Patricia Moore (Greene)
51020 Main Road
Southold, NY 11971
Please take notice that your application dated June 19, 2008
For permit for "as built" accessory garage to be converted to dwelling addition
Location of property: 30653 County Road 48, Peconic, NY
County Tax Map No. 1000 - Section 73 Block~4 Lot5
Is returned herewith and disapproved on the following grounds:
The proposed addition, on this conforming 84,903 +/- sq. ft. lot located in the AC Zone,
is not permitted pursuant to Article III, Section 280-14, Bulk Schedule, minimum side
yard set back required is 20 feet, the survey shows the garage setback 10 feet from the
side property line.
NOTE*- Based on inspectors' report dated 12/19/07 the "as built" garage included a
kitchen and bedrooms. (Attached)
This permit(and garage location) was issued in error under building permit #30680. At
the time of the issuance of the permit (10/4/04), the code required a 20 foot side yard
setback. The garage is located at a 10 foot setback from the side yard line.
Disapproval based on survey of Peconic Surveyors dated 5/15/08 and hand drawn plans
submitted 3/20/09.
Authorized Signature
Note to Applicant: Any change or deviation to the above referenced application, may
require further review by the Southold Town Building Department.
CC: file, Z.B.A.
Office Location:
Town Annex/First Floor. Capital One Bank
54375 Main Road (at Yonngs Avenue)
Southold. NY 11971
Mailing Address:
53095 Main Road
RO. Box 1179
Southold. NY 11971-0959
http:#southoldtown.north fork.net
BOARD OF APPEALS
TOWN OF SOUTHOLD
Tel. (631) 765-1809 Fax (631) 765-9064
FINDINGS, DELIBERATIONS AND DETERMINATION
MEETING OF MAY 28, 2009
ZBA File ~6235 - ANDREW and ELIZABETH GREENE
Location of Property: 30653 C.R. 48, a/lEa Middle Road or North Road), Peconic; CTM 73-4-5
SEQRA DETERMINATION: The Zoning Board of Appeals nas visited the property under
consideration in this application and determines that this review falls under the Type II category of
the State's List of Actions, without further stecs under SEQRA.
SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under
the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County
Department of Planning issued its reply stating that this application is considered a malter for local
determination as there appears to be no significant'county-wide or inter-community impact.
LWRP: This application is exempt under Town Code Chapter 268 for the reason the relief
requested is in a lOCation greater than 100 feet from the tOp of the Long Island Sound bluffor bank,
and greater than 100 feet from the established Coastal Zone Management boundary line.
,PROPERTY, FACTS: The property is located in lhe R-80 Residential Zone District and the
applicant's survey shows approximately 74,000 square feet (1.7 acres) of buiidable area, and
approximately 11,200 square feet of unbuildable area north of the Coastal Zone Managemenl
boundary line, or total area of 1.9491 acres. The property is improved with a single-family dwelling
and new garage building under construction (Building Permil # 29436).
BASIS OF APPLICATION: Request for a Variance under Code Section 280-14, based on the
Building inspector's Mamh 20, 2009 Notice of Disapproval concerning an amended application for
a building permit to construct an addition (conditioned space) to attach the as-built construction to
the dwelling, which as-built construction will be less than the code-required 20 fl. minimum from the
side yard. :
RELIEF REQUESTED (Ori,qinal Application): The applicants' original application was based on the
Building InspeCtor's Notice of Disapproval dated June 30, 2008 and their building permit application
for non-permitted Use of an as-bUilt accessory building (as:built accessory apartment). This
Page 2- May 28, 2009
ZBA # 8235- A~drew and Elizabeth Greene
CTM 73-4-5 :
vadanca application was withdrawn by the applicants on Mamh 20, 2009 regarding the use
variance for as-built accessory apartment and/or home office uso in the new garage conslruction,
which uses were not permitted under Zoning Code Section 280-12 and Section 280-13C-2-a.
RELIEF REQUESTED (Amended Application): Subsequent to the January 9, 2009 public hearing,
the owners submitted an amended appliCation to the Building Inspector, and based on the Building
Inspector's Mamh 20, 2009 Notice of'Disapproval, a variance application was filed requesting a
side yard setback at 10 feet of the accessory building, proposing conformity of the building floor
area, with one of the following two options: (1) proposing an addition converting the building to a
conforming use and connecting the accessory garage to the dwelling, resulting in only an area
variance for a side yard setback at 10 feet instead of the code-required 20 feet from the side yard
property line provided under Code Section 280-14, or (2) proposing the as-built setback in the
event the connection to the dwelling is not built for a 10 ft. side yard setback after converting the
as-built accessory garage to a .conforming use as per Code (without the as-built kitchen,
bedroom/sleeping facilities, full bathroom).
FINDINGS OF FACT
The Zoning Bo~ard of Appeals held a public headng on this application on January 8, 2009 and Apdl
23, 2009, at which time written and oral evidence were presenled. Based upon all testimony,
documenta~n, personal inspection of the property, and other evidence, the Zoning Board finds the
following facts to be true and relevant:
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and
pemonal inspections, the Board makes the following findings:
After a groat deal of testimony and discussions between the applicants, the applicants' attorney,
and Board Members at the first hearing on January 8, 2009, the applicants found themselves in a
dilemma since'the Board was very reluctant about granting a second dwelling on this property for
the as-built cortstruction without permits. This left the applicants with only one of the following two
options: to cbnnect the main dwelling to the accessory building with a heated connection and to
bring the use of the building area into conformity with the Code, or alternatively nol connect the
main dwelling -[o this building and to remove the nonconforming as-built home office and living
space area. ('The first option is similar to that required under ZBA File ~5667 issued March 10,
2005 concemirlg premises located in Odent, NY.)
1. Town Law §267-b(3)(b)(3)(1). Grant of the a[tbmative relief (allowing only a setback reduction
on a single ~ide yard) will not produce an undesirable change in the character of the neighborhood
or a detriment to nearby properties. The applicants submitted an amended application, removing
the request for relief for a use variance, and seeking alternative relief to connect their home and
the two story-garage (presently a detached, separate building with non-permitted living space).
The accessory building that exisls is not conforming as built, since it contains as-built sleeping
quarters on th~ second story and has only 10 feet from the side 10t line instead of Ihe code required
20 ft. setback. ! The connection between the two buildings as proposed will be conditioned, heated
space, to bring, the building into cohformity with the code for either an accessory building use, or an
Page 3 - May 28, 2009
ZBA # 6235 - Andrew and Elizabelh Greene
CTM 73-4-5
addition to the dwelling. The dimensions of the garage without the connection are 24.3' by 36.2'
and lies 10 feet from the easterly property line. The altemative relief that is requested is an area
variance for the as-built 10 ~t. side yard' setback, resulting in a 50% reduction in code requirement
from the 20 fl. minimum requirement. The applicants have agreed and will remove all kitchen
facilities, to include wet bar from the as built second story improvements made to the as-built
portions of this bUilding.
2. Town LaW ~267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some
method, feasible for the applicant to pursue, other than an area variance.
The applicants have two options: (1) to link the freestanding garage to the two-story, single-family
home, accommodated by a heated hallway-type connection between the two buildings, to meet the
code use pmvieions, and not as an accessory apartment, or (2) to convert with a building permit,
the as-built detached garage building to a legal, accessory garage without kitchen or- sleeping
quarters, applying the 10 ft. side yard variance granted in this application, without the need to apply
with a new application.
3. Town Law ~67-b{3)(b)(3). The vananca requested herein, is substantial, resulting in a 50%
reduction from'the code required 20 feet, and them is no alternative to increase the setback
because the building location was noted as an allowable setback under building permit #
4. Town Law.~267~b(31tb)15). The difficulty is self created and is related to the as built areas of the
accessory garage construction under Building Permit # 29436
5. Town LaW .~267-b(3){b){4). No evidence has been submitted to suggest that a variance in this
residential community will have an adverse impact on the physical or environmental conditions in
the neighborhood.
6, Town Law ,~267-b Grant of the amended relief is the minimum action necessary and adequate
to enable the applicants to enjoy the benefit of new construction (alternative relief with conditions
as an accessory or altsmativeiy as an addition to the dwelling), while prese~ng and protecting the
character of the neighborhood.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing
test under NeW York Town Law 267-B, motion was offered by Chairman Goehfinger, seconded by
Member We sman, and duly carried, to
DENY the ~application requested conceming the as-buitt structure, denying a second dwelling
'unit on this property, and denying an accessory garage with nonconforming kitchen and/or sleeping
quarters, AND TO
GRANT relief as requested in the amended application subject to the following conditions:
1 A second kitchen or second dwelling is not permitted on the premises.
Page 4 - May 28, 2009
ZBA # 6235 - N~drew and Elizabeth Greene
CTM 73-4-5
2. Prior to the issuance of any Certificate of. Occupancy, the Building Inspector and the
pm. perry owner are requestedto' (a) notify the Zoning Board of Appeals that the above
conditions have been completed, and (b) when completed, to contact the Board of
Appeals and arrange for an inspection by a representative of the Zoning Board of Appeals
and followed up in writing by ZBA to the Building Inspector, for the purpose of acceptance
or other steps to conform to the above condition).
3. The connection from the house shall be heated, conditioned space connecting the
accessory structure, for the purpose of meeting the use provisions of the zoning code for
only=one single-family dwelling unil on the premises. The connection shall be as per code
(at least 5 feet wide, 33.5 feet in ~ngth, and minimum 7.5 feet height).
4. The Board requires a certified copy of the plans and specifications regarding the one-
story connection unit together with the type of heating, lighting and foundation for the
structural connection.
5. Ntematively, if owner decides not to attach the accessory building to the main dwelling
by conditioned space/connection, a ce~fied copy of the plans and specifications prepared
by a licensed professional is required, with removal of kitchen and any other
nonconforming area, for conformity as an accessory building as per code before a
Certificate 'of Occupancy is issued.
6. A Declaration of Covenants and Restrictions shall be submitted in recordable form
'within 90 days of the receipt of this decision for approval by the Town Attomey, stating
resb'icti0ns at this property for limitation of only one single-family dwelling on this property
and garage addition or accessory garage as per code (and with variance for 10 ft. side
yard. This Covenant must be filed by the applicant's attorney with the Suffolk County
Clerk's Office, and a conformed copy shall be fumished to ZBA and Town Attorney for the
permanent official ZBA and Building Department files.
The above g'onditions shall be w~en into the Building Inspector's Certificate of Occupancy, when
issued.
Any deviation from the valance given such as extensions, or demdiilic~s which are not shown on the applicant's
diagrams or survey site maps, are not authorized under this application when involving nonco, nformiaas under the
zoning code. This .action does not authorize or condone any current or Mure use, setbaok or other feature o~ the
subject property that ma), vidiate the Zoning Code, other ~an such uses, setban~s and other features as are expressly
addressed in this action.
The Beard reserves the right to substitute a similar design that is de minimus in nature for an alteralion that does not
increase the degr ,~ of nonconformity.. '
Vote of the Board: Ayes: Members Goe~h~on,all~an, ~,Scbneider..(Member
Olive was abssnt) Th ,eso u,on .. 'au y dop ed (4-0> .
../' ,.....~-"" ~.~r_.,,~/ ~- / /__.,,/,~.4 --RECEIVED
,- GE.~. GOEHRINGER, CHAIRMAN z,.--
- '~....Apl~'roved for Filing / dui{ 2 2009
wn Cierl~
Elizabeth Thompson, Architect
250 Mercer Street B-806
New York, NY 10012
Tel/fax 212-614-7180
ElizabethThompsonArchitect.com
P. O. Box 464, Orient, NY 11957
Tel/fax 631-323-3873
Sept. 20, 2004
Damon Rallis
Building Dept. ~ Annex
Southold Town Hall
Southold, NY 11971
631-765-1802
Re: 1000-73-4-5
30653 County Rd. 48
Peconic, NY
Dear Damon,
Enclosed is a complete application package for a building permit for a new garage for the Greene
residence. The residence currently is under construction. An amended health permit is enclosed
approving the plumbing in the garage to be connected to the existing house septic system as shown.
Please let me know if there is any additional information that you need.
Elizabeth Thompson
Elizabeth Thompson, Architect
250 Mercer Street B-806
New York, NY 10012
Tel/fax 212-614-7180
ElizabethThompsonArchitect.com
P. O. Box 464, Orient, NY 11957
Tel/fax 631-323-3873
Sept. 29, 2004
Damon Rallis
Building Dept.
Southold Town Hall Annex
Southold, NY 11971
Re: Greene Residence
1000-73-4-5
Dear Damon,
Enclosed is follow-up information requested by you for the garage permit on the above referenced
residence.
-3 signed and sealed copies of revised drawings G-1 & G-5
-1 copy of revised Rescheck Compliance Certificate
Due to the change you requested in the Rescheck form, an additional '/2" of continuous rigid
insulation had to be added to the cathedral ceiling to reach compliance. This has been noted on
drawing G-5. Please call me when the permit is ready or if you have any further questions.
Elizabeth Thompson
Town Hall~ 53095 Main Road
P.O. Box 1179
Southold, New York I 1971-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
Fax (631 ) 765-9502
Telephone (631 ) 765-1802
October 12th, 2006
Andrew J. Greene
30653 CR 48
Peconic, N.Y. 11958
RE: 30653 CR 48
SCTM# 073 0004 005
Dear Mr. Greene,
Please be advised that your Building Permit #30680 issued October 4th, 2004 has
expired. According to the Code of the Town of Southold, a Certificate of Occupancy
must be issued prior to use of the structure.
To renew your Building Permit, please submit a fee of $593.40 at that time we can
schedule an inspection by one of our Building Inspector's.
If you have any questions, please call us at 631-765-1802.
Respectfully,
SOUTHOLD TOWN BUILDING DEPT.
Town Hall. 53095 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Fax (631) 765-9502
Telephone (631) 765- ! 802
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
March 30th, 2007
Andrew J. Greene
30653 CR 48
Peconic, N.Y. 11958
2ND NOTICE
RE: 30653 CR 48 (alteration/addition/garage)
SCTM: 73 4 5
Dear Mr. Greene,
Please be advised that your Building Permit #30680 issued October 4th, 2004 has
expired. According to the Code of the Town of Southold, a Certificate of Occupancy
must be issued prior to use of the structure.
To renew your Building Permit, please submit a fee of 593.40; at that time we can
schedule an inspection by one of our Building Inspector's.
If you have any questions, please call us at 631-765-1802.
Respectfully,
SOUTHOLD TOWN BUILDING DEPT.
PATRICIA A. FINNEGAN
TOWN ATTORNEY
patricia.finnegan@town.southold.ny.us
KIERAN M. CORC'ORAN
ASSISTANT TOWN ATTORNEY
kieran.corcoran@town.southold.ny.us
LORI M. HULSE
ASSISTANT TOWN ATTORNEY
lori.hulse@town.southold.ny.us
SCOTT A. RUSSELL
Supervisor
Town Hall Annex, 54375 Route 25
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1939
Facsimile (631) 765-6639
OFFICE OF THE TOWN ATTORNEY
TOWN OF SOUTHOLD
December 28, 2007
Andrew & Elizabeth Greene
30653 CR 48
Peconic NY 11958
Re; Property at 30653 CR 48; SCTM# 1000-73-4-5
Dear Mr. & Mrs. Greene,
Please be advised that a complaint has been forwarded to this office by the Building
Department for enforcement. During a recent inspection it was observed that
construction to the accessory garage has exceeded the scope of the permit
In addition, a non-permitted use (living space) has been established within the structure.
This activity represents several violations of Southold Town Code.
Please take the steps necessary to remedy the violations immediately. Contact the
Building Department for instructions on a lawful remedy. Failure to comply will result in
legal action by this office.
Thank you for your anticipated cooperation.
Sincerely,
Edward Forrester
Director of Code Enforcement
Date
File #
TOWN OF SOUTHOLD COMPLAtNT REFERRAL FORM
Property Owner:
Address:
NATURE OF COMPLAINT:
ACTION TAKEN:
Optional:
Complainant:
Address
Report Taken By:
Date Referred to Code Enforcement:
Mail In Person
Phone:
Date: //)_ ~-/~.--o 7
CODE ENFORCEHENT REPORT
SITE INSPECTION REPORT/DATE:
ACTION/DATE:
M E R Y L I< R A M E r
a r c h i t e c t
Mr. Michael Verity
Southold Town Building Dept.
Southold Town Hall
PO Box 1179
$outhold, NY 11971
February 8, 2011
RE: Greene Residence
Tax Map # 1000-73-4-5
TO~N OF SOUTHO1 D .}
Dear Michael,
I have recently been retained by the owners of the above property to provide drawings that will comply with the
Declaration of Covenants and Restrictions issued by the Zoning Board of appeals on August 31, 2009, in order
to secure the Certificate of Occupancy for the garage.
Item #5 states that, 'if owner decides not to attach the accessory building to the main dwelling by conditioned
space/connection, a certified copy of the plans and specifications prepared by a licensed professional is
required, with removal of kitchen and any other nonconforming area as an accessory building as per code
before a Certificate of Occupancy is issued."
Enclosed please find three stamped drawings of the second floor plan of the garage building. The drawing
instructs the contractor to remove the bathtub from the bathroom, leaving the toilet and sink intact. The owner
has already removed the microwave oven from the wet bar area.
I spoke with Leslie Weisman, chairman of the Zoning Board of appeals on Februa~ 2"d. She agreed that the
above changes would satisfy the Zoning Board of appeals' Declaration.
Please let me know if you require further documentation regarding this permit application.
/Be~, Regards, .//~
Encl.
Cc: Andrew and Liz Greene
218 FRONT STREET PO. BOX 683 GREENPORT, NY 11944 631-477-8736 WWW.MKARCHITECT.COM
From: "DiGiuseppe, John" <John. DiGiuseppe@suffolkcountyny.gov>
Subject: RE: R10020014
Date: March 1, 2011 9:53:13 AM EST
To: "MERYL KRAMER" <meryl@mkarchitect.com>
Have they changed anything since our "Final" approval (green stamp) was issued in 2005? They
currently have our approval for plumbing fixtures in the garage. They currently have a sanitary
system that allows for a maximum of 4 total bedrooms. This would include the house and
garage. If they are renovating the garage and adding bedrooms which would bring them in
excess of 4, they may need our permit to increase the size of the sanitary system to
accommodate the extra bedrooms.
John DiGiuseppe
Senior Public Health Sanitarian
Suffolk County Dept. of Health
Office of Wastewater Management
MAR 2 2 2011
BLDGDEPr.
TOWN OF SOUTHOLD
631-852-5700
From-' MERYL KRAMER [mailto:meryl@mkarchitect.com]
Sent-' Monday, February 28, 2011 3:41 PM
TO: DiGiuseppe, John
Subject: R10020014
Hi John,
Thanks for you message. I was away on vacation last week.
You mentioned in you message that the existing 1200 gallon septic tank with two 8 foot
diameter by 8 foot deep cesspools was approved for the 4 bedroom house with a
garage/office accessory structure.
I wanted to clarify that the septic system that exists on the property will suffice for the
proposed use of the accessory structure.
Will the current system meet the Suffolk County Dept. of Health Code if the garage
building has a bathroom and a wet bar? We are trying to get a Certificate of
Occupancy for the accessory structure, and the Building Department is requesting that
we get a permit from your office.
Thank you,
Meryl
M E R Y L K R A M E R
a r c h i t e C t
BLDG, DEPT
TOWN OF SOLJTHOI O
Mr. Michael Verity
Southold Town Building Dept.
Southold Town Hall
PO Box 1179
Southold, NY 11971
March 18, 2011
RE:
Greene Residence
Tax Map # 1000-73-04-05
Dear Michael,
This letter and attachments will provide you with all of the items that you requested in order to secure the
Certificate of Occupancy:
1. Three copies of the second floor plan of the garage, showing partition walls and bath tub and
plumbing to be removed
2. A copy of the ResCheck report showing compliance with the NYS energ~ code
3. A copy of the e mail correspondence from the SCDHS indicating that the final approval
includes the garage with plumbing fixtures
Please let me know if you require further documentation regarding this permit application.
BestRe~s,
Encl.
Cc: Elizabeth and Andrew Greene
218 FRONT STREET P.O. BOX 683 GREENPORT, NY 11944 63~.-477-873a WWW,MKARCHIIECI.COM
':?CDHS ReL # R10-'02-0014
FFST HOLF
Loom
Silly Sand
SM
TEST
BORING
P~OV~. CL~4~OUT
EVERY ,.,,~0' M~I.
Wa/er ~ ~ I ~11
bro~
~Y ~ i
· an~ a~
~ 46'
· ~1~ 1~ ....
~m ~r re / ~2
~E ~ ~NT~ TO
~o~
D~I. UN~
· ~LL
CP. 150' ·
ELEVATIONS ARE REFERENCED TO N.G.V.D.
· '~ MONUMENT
· "PIPE
AREA = 1.9491 acres
retie[tm
\
\
I ~m le7811or wffh the STANDARDS FOR APPROVAL
AND CONSTRUCTION OF SUBSURFACE SEWAGE
DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES
~nd will ~ b% t~e condl#o~s se! forth therein and on /he
permti to construct,
The locations of wells end cesspools
shown her. eon ere from field observdions.
end o~ from dele obldned from o/hers.
COASTAL EROSION HAZARD LINE.
COASTAL EROSION HAZARD AREA MAPS
PHOTO NO, 57 - 556 ~ 83
RT ED TO,
~ .... CRO~CTION- SEPTIC SYSTEM
~OPD~D ~T~
POOL IZ DEEP ~ITH
'Cea'se fo Flnl
Br. ~ O~rk
8r. S~
Some Grovel
Some ~. E
TOWN OF SOUTHOLD
SUFFO L COUNTY,
73-04-05
SCAI.~.. 1" = 60'
rest e~Z ~' i S~ . DEC. 2~, 2001
3' : S~l. 26, 2~ tre~)
23' ~% Cl~ ~ ~e~ Le~' gg g~ {~A ~R'I ~ L~$)
Fine Br.
~af~ Br.
20 Tr~e
Ol- 255
I am laml4or v~lli~ fhe STANDARDS FOR APPROVAL
AND CONSTRUCTION OF' .~UBSURFACE SEEIA6E
DISPOSAL SYSTEMS FOR SINC~E FAMILY RESIDENCES
~g ~oo%~y~,~URVEY OF PROPERTY
A T PECO~C
TOWN OF SOUTHOLD
SUFFOLK COUNT~ N~
~-73-~-05
SCA~ I' = 60'
Permit Number
Checked By/Date
REScheck Compliance Certificate
New York State Energy Conservation Construction Code
REScheckSoRwarc Version 3.6 Release 1
Data filename: CSProgram Files\Check~RESchcck\Greene Garage.rck
PROJECT TITLE: Greene Residence Garage
COUNTY: Suffolk
STATE: New York
HDD: 5750
CONSTRUCTION TYPE: Detached I or 2 Family
HEATING TYPE: Non-Electric
WINDOW / WALL RATIO: 0.41
DATE: 09/29/04
DATE OF PLANS: Sept. 15, 2004
PROJECT DESCRIPTION:
3-car garage with 2nd FI. habitable space
DESIGNER/CONTRACTOR:
Elizabeth Thompson, Architect
Torkelson Builders
COMPLIANCE: Passes
Maximum UA - 130
Your Home UA = 130
0.0% Better Than Code (UA)
Gross Glazing
Area or Cavity Cont. or Door
perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Tress 90 19.0 21.6 2
Ceiling 2: Cathedral Ceiling (no attic) 1038 31.0 5.0 29
Wall 1: Wood Frame, 16" o.c. 442 19.0 2.6 13
Window 1: Wood Frame:Double Pane with Low-E 181 0.280 51
Door 1: Solid 20 0.510 10
Floor I: All-Wood Joist/Truss:Over Unconditioned Space 864 31.0 2.2 25
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the buildiog
plans, specifications, and other calculations submitted with this permit application. The proposed systems have been
designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design
Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and
professional judgment, such plans or specifications are in compliance with this Code.
I
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSot'rware Version 3.6 Release 1
DATE: 09/29/04
PROJECT TITLE: Greene Residence Garage
Bldg.
Dept.
Use
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss,
R~ 19.0 cavity + R-21.6 continuous insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic),
R-31.0 cavity + R-5.0 continuous insulation
Comments:
Above-Grade Wails:
1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity + R-2.6 continuous insulation
Comments:
Windows:
I. Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.280
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
Comments:
] No
Doors:
1. Door 1: Solid, U-factor: 0.510
Comments:
Floors:
1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,
R-31.0 cavity + R-2.2 continuous insulation
Comments:
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that am sources of air
leakage must be sealed.
Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a
3" clearance from insulation.
Vapor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values and glazing U-factom must be clearly marked on the building plans or specifications.
Duet Insulation:
Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
Retain ducts in unconditioned attics or outside the building must be insulated to R-4.
Supply ducts in unconditioned spaces must be insulated to R-8.
Return ducts in unconditioned spaces (except basements) must be insulated to R-
Return ducts in unconditioned spaces (except basements) must be insulated to R-2..
Insulation is not required on return ducts in basements.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated U L 181A or UL 181B.
F~rception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
Separate electric meters are required for each dwelling unit.
Fireplaces:
Fireplaces must be installed with tight fitting non-combustible fireplace doors.
Fireplaces must be provided with a soume of combustion air, as required by the Fireplace construction
provisions of the Building Code of New York State, the Residential Code of New York State or
the New York City Building Code, as applicable.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part ora circulating system.
Insulate circulating hot water pipes to the levels in Table I.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulatinn:
HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the
levels in Table 2.
Table 1: Minimum lnsulation Thickness for Circulating Hot }Yater Pipes.
Insulation Thickness in Inches bv Pine Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature ( FI Un to 1" Un to 1.25" [,~" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches bv Pine Sizes
Pinine System Tvnes Range ( F/ ;~" Runouts !," and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
Generated by REScheck-Web Software
Compliance Certificate
MAR 2 2 20~!
BLDG DEPT
TOW~ OF SOUTHOLD
Project Title: Greene Residence Garage
Energy Code: 2010 New York Energy Conservation
Construction Code
Location: Suffolk County, New York
Construction Type: Detached I or 2 Family
Building Orientation: Bldg. faces 0 deg. from North
Conditioned Floor Area: 864 fi2
Glazing Area Percentage: 23%
Heating Degree Days: 5750
Climate Zone: 4
Construction Site:
30653 CR 48
Peconic, New York
Permit # 34775
Permit Date: 6/15/2009
Owner/Agent:
Andrew and Elizabeth Greene
Compliance: 4.5% Better Than Code
Designer,Contractor:
Meryl Kramer
Meryl Kramer Architect
PO BOx 683
Greendort, New York 11944
631-477-8736
maP/l@ mkarchitect.com
Wall: Wood Frame, 15in. o.c.
Orientation: Left Side
Window 11: Wood Frame, Double Pane
SHGC: 0.32
Orientation: Left Side
Window 12: Wood Frame, Double Pane
SHGC: 0.32
Orientation: Left Side
Window 13: Wood Frame, Double Pane
SHGC: 0.32
Orientation: Left Side
Window 14: Wood Frame, Double Pane
SHGC: 032
Orientation: Left Side
Wall 1: Wood Frame, 16in. o.c.
Orientation: Front
Window 6: Wood Frame, Double Pane
SHGC: 0.32
Orientation: Front
Window 6A: Wood Frame, Double Pane
SHGC: 0.36
Orientation: Front
Wall 3: Wood Frame, 16in. o.c
Orientation: Right Side
Window 7: WOod Frame, Double Pane
SHGC: 0.32
Orientation: Right Side
Window 8: WOod Frame, Double Pane
SHGC: 0.32
Orientation: Right Side
Wall 4: Wood Frame, 16in. o.c.
Orientation: Back
288 19.0 2.9 11
10 0.310 3
2O 0310 6
20 0.310 6
10 0.310 3
192 190 2.9 7
32 0.310 10
14 0.290 4
288 190 2.9 12
27 0,310 8
27 0,310 8
192 19.0 2.9 7
Project Title: Greene Residence Garage Report date: 03/18/11
Data fllename: Page 1 of 5
Window 9: Wned Frame, Double Pane
SHGC: 0.32
Orientation: Back
Window 10: Wood Frame, Double Pane
SHGC: 0.32
Ceiling: Flat or Scissor Truss
Floor: All*Wood Joist/Truss Over Uncond. Space
30 0.310 9
30 0.310 9
864 30,0 1.1 29
864 30.0 2.3 26
CompSan~e Statement: The proposeq building deign desc~bed here is consistent with the building i~a~s, speclflcaaorts, and other
calculatio~s submitted with the permit applica~on. The proposed building has been designed to meet the 2010 New York Enemy Coneewation
Co~sttrucflon Code requirements in RESch~ck-Web and to comgly~wiih the ma~i[~rmnts Ilated in the REScheck In~
Data filename: Page 2 of 5
MAR 2 2 2011
BLDG. DEP'[
TOWN OF SOUTHOLD
EXIST. STAIRS TO
REMAIN
UNDERCOUNTER
REF. AND SINK TO
REMAIN
II I
WET BAR STORAGF~/WORKSHOP
REMOVE EXIST.
BATHTUB AND
PLUMBING-PATCH
WALL AND FLOOR
TILE AS REQ'D
BATHROOM
BEMOVI DOOBS AND
PARTITI~ )N WALLS AS
SHOWN
WALL
I II I I Il I
2'-0" KNEE WALL
EXISTING CLOSETTO
REMIAN
---------_ LINE OF DORMER
ABOVE, TYP.
~ 2'-0" KNEE WALL
M E R Y L K R A M E R
a r C h i t e c t
GREENE RESIDENCE - GARAG[~
SECOND FLOOR PLAN k'=l'-0'
3-14-11
218 FRONT STREET P.O, BOX 683 GREENPORT, NY 11944
631-477-87'~6
L
CERTIFICATION OF
NAILING & CONNECTIONS
REQUIRED:
PLUMBER CERTIFICATION
ON LEAD CONTENT BEFORE
CERTIFICATE OF OCCUPANCY
SOLDER USED IN WATER
SUPPLY SYSTEM CANNOT
EXCEED 2/10 OF 1% LEAD.
0'
LJfl Hr'f Po~~
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
. J I //¢ SOUTHOLDTOWNZBA
,//////
-¢-V-/-j~ $OUTHOLu TOWN TRUOTEES
t I/t i N.Y,S. DEC
DO NOT PROCEED WITH
FRAMING UNTIL SURVEY
OF FOUNDATION LOCATION
HAS BEEN APPROVED.
PLUMBING
ALL PLUMBING WASTE
& WATER LINES NEED
TESTING BEFORE COVERING
~OOD ZO~ ,d~* _' - '
COMPLY WITH CHAPq ER 46"
FLOOD DAMAGE pREVENTION
~OUTHOLO ToWN CODE.
RETAIN STORM WATER RUNOFF
PURSUANT TO SECTION 45-10C
D\VA. uo, ~1 f~
~ ~ ~Y~l~M
I
~T~A~ P~H~ I q ~OU~H
~,PboR~, ~ p~,,XVp%~,,i J~ ~5V6~ ~UlbPlH4 5~1¢W
PCf~ I~ ~N~V~ BUIcPIH4 ~IDH5
Cq ~H¢~ ~; Hlbbkvo~ p~T~ID~
Gl .FouHp~o~ ~ ISrpu, F~HIH~
Elizabeth Thompson. ArchHect ~m~ ~lP~ J/l~/o~ . / j
250 Mercer St. Suite B ~6 Title '-- ~ Scale
New York, NY 212-6M-7180 - ~1~ ~P~ %~d-~j~
] 0012 ETArchltect~nyc.~r.co m
OF THE TOWN CODE,
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
ALL CONSTRUCTION SHALL
~MEET THE REQUIREMENTS OF THE
CODES OF NEW YOFIK STATE. ,
T
-t
J_
Elizabeth Thompson. Architect
250 Mercer St.
New York, NY
10012
Suite B 806
212-614-7180
ET^rchitect @nyc.tr.com
Job
Title
Da?
Scale
J~"~l'-dI
I
Job Date
Elizabeth Thompson. Architect &~¢I4D ~-E~I12¢JJDE, ~llt~Jo4
250 Mercer St, Suile B 806 Title Scale
New York, NY 212-614-7180 .:~ ~¢L,r_~ ~, _1/4!'-'1;0"
1001:2 ETArchitect@nyc.rr.com ~1 J~t~'rl~L-, j2j~
'x
6~
-" ~l
Elizabeth Thompson. Architect
250 Mercer St.
New York, NY
10012
Suite B 806
212-614-7180
EfArchitect@nyc.rr.com
Title
Elizabeth Thompson. Architect
250 Mercer SI. Suiie B 806
New York, NY 212-614-7180
10012 ETArehifect@nye.rr .corn
Job
Title
Date
l~'rAIbtH(~ GPrAb~ i~t.A'f'~l P!~114
~oP ~
'PfP. \WAI,U G6O'Floki
pI'F6B bo~,%loM
Elizabeth Thompson. Architect
250 Mercer St.
New York, NY
10012
Suite B 806
212-614-7180
ETArchltect@nyc.rr.com
Job
lille
\~AL~ GFZXIot4 .
'jo HA-i U huoo%6
Date
scale
GASLE ROOFS
e < I0e
GABLE ROOFS
10~< e ( 45~'
lO(~< 9 ¢ 450
I0~< S ( 300
HIP ROOFS
PROVIDE 8d NAILS · 4" O.C. AT PERI/v~TER ~NTERIOR
PORTIONS OF PANELS IN H~GH PRESSURE ZONEB
NOTE: a -- 4 FT. E4 ALL CASES
COMPONENT AND CLADDING PRESSURE ZONES
II
TYPICAL
ELEVATION
HOLD DOWN + SHEAR CONNECTION CRiTiCAL PATH
END VIEW -
I/2' DIA. GALVANIZED
MACHINE BLOT W/ WABH,~:{S
AT [2° O.C,.
SIDE VIEW
LVL BOLTING DETAIL
BOLT1N~ SlblLAR FOR DCUBLE LVL
DESIGN CRITERIA:
GROUND SNOW LOAD - 45 PSF.
FIRST LEVEL - 40 p~F. L,L.
LIVING AREAS - 40 PSF. L.L.
BEDROOMS - 30 PSF. L,L.
WIND SPEED - 120 MgH
SEISMIC DESIGN CATEGORY - S
WEATHERING - SEVERE
FROST LINE DEPTH -
TERMITE - MODERATE TO HEAVY
DECAY - SLIGHT
ICE SHIELD UNDERLAYMENT REQUIRED - YES
DESIGN CRITERIA: . '
DESIGN IN ACCORDANCE WITH AMERICAN FOREST PRODUCTS WOOD FRAME
CONSTRUCTION MANUAL FOR I ~- 2 FAMILY HOUSE - I~IE~~.
Job Date
Elizabeth Thompson. Architect ~r-~'¢ - ' ,ff/l~fo~r , .,~,
250 Mercer St. Suite B 806 Title dA~(.~ Scale
100t 2 ETAi chitect @nyc.rr.com
CONCRETE NOTES
1. DESIGN, MATERIALS'~ METHODS OF CONSTRUCTION SHALL COMPLY W~TH THE
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI 318 OF THE
AMERICAN CONCRETE iNSTITUTE - LATEST EDITION. ULTIMATE DESIGN
STRENGTH FOR ALL REINFORCED CONCRETE SHALL BE 3000 PSI. AT 28 DAYS
EXCEPT CONCRETE SLABS WHICH SHALL BE 4000.PSL
CONCRETE TO BE POURED IN AMBIENT TEMPERATURES OF 40 + DEG. F.. IF
POURED IN COLDER WEATHER THE CONCRETE MUST BE PROTECTED FROM
FREEZING FOR A PERIOD OF 14 DAYS.
,A. KEEP FORMS IN p~_ACE, COVER TOP AND SIDES OF FORMS WITH TARPS
FOR PROTECTION FROM WIND FOR A MINIMUM OF 3 DAYS AFTER
Pouh. ' ' '
B. AFTER FORMS ARE REMOVED, PROVIDE INSULATED TARPS TO HOLD
HEAT AND PROTECT FROM WIND FOR A PERIOD OF 14 DAYS AFTER
POUR,
3. CONCRETE & REINFORCING MATERIALS SHALL CONFORM TO THE FOLLOWING
STANDARDS - LATEST EDITION,
A. PORTLAND CEMENT AS PER ASTM C1 SO -TYPE t.
CONCRETE AGGREGATES AS PER ASTM C33, 3/4" MAX. SIZE·
C. WATER SMALL BE CLEAN & FREE FROM INJURIOUS AMOUNT OF OILS,
ACIDS, ALKALIS, SALT. ORGANIC MATERIALS & DELETERIOUS
SUBSTANCES,
D. REINFORCING BARS SHALL BE INTERMEDIATE GRADE NEW BILLET STEEL,
DEFORIvlED AS PER ASTM AB15, GRADE B0. ALL SPLICES SHALL BE A
MINIMUM OF 40 DIA, IN LENGTH. NOOKS AND TIES SHALL CONFORM
TO C.R,S.I. STANDARDS,
E. COLD DRAWN WIRE OR WELDED WIRE FABRIC AS PER ASTM AB2-84
AND A18B-84.
F,WATERPROOFING AS PER ACI E15,1R-79.
4. ALL CONCRETE SHALL BE AIR ENTRAINED ( 3-5% RETENTION ).
5. ALL FOOTINGS AND STRUCTURAL SLABS SHALL BE POURED ON UNDISTURBED
VIRGIN SOIL HAVING A MINIMUM BEARING CAPACITY OF TWO TONS PER SO.
FT.
6. THE CONCRETE CONTRACTOR SHALL COOPERATE IN SETTING ALL ANCHOR
BOLTS, INSERTS, SI.EEVES, ETC, AS REQUIRED BY OTHER TRADES·,
7. LEGS OF REBAR ACCESSORIES SHALL BE PLASTIC TIPPED. ALL SNAP TIES AND
WALL PENETRATIONS SHALL BE CU~ BACK AND GROUTED SO As'To pRECLUDE
ANY CORROSIDN.
8. ADMIXTURES CONTAINING CHLORIDES SHALL BE PROHIBITED.
S. ALL REINFORCEMENT SHALL BE TIED IN PLACE BEFORE CONCRETE IS POURED,
ALL REINFORCEM£NT AND FABRIC FOR CONCRETE POURED ON GROUND SHALL
BE SUPPORTED ON PRECAST BRICKS OR APPROVED CHAIRS.
10. ALL REINFORCING B/~RS SHALL BE C~0NTINUOUS EXCEPT AS NOTED, LAPPED
PER ACi 318, CLASS "C", WITH 40 DIAMETERS MINIMUM, BENT AROUND
CORNERS AND HOOKED AT NON- CONTINUOUS ENDS. FOR FRAMED SLABS,
LAP TOP BARS AT MID SPAN BETWEEN SUPPORTS AND BOTTOM BARS AT
SUPPORTS, REVERSE FOR FOUNDATION MATS. STAGGER SPLICES AND OFFSET'
SPLICES OF BARS AT OPPOSITE FACES.
11. ALL SLAB-ON-GRADE T, HI~:KNESSES SHOWN ARE MINIMUM THICKNESSES TO BE
USED. INCREASE AS REQUIRED FOR DRAINAGE PITCH.
12. EXCEPT AS NOTED, ALL POUR STOPS SHALL BE TREATED AS CONSTRUCTION
JOINTS AND SHALL HAVE,KEYS AND CONTINUOUS REBAR. WALL SECTIONS
SHALL BE PLACE[) ALTERNATIVELY OR WiTH A MINIMUM OF 24 HOURS
BETWEEN ADJACENT POURS.
t3. FOR CONCRETE WALLS~ VERTICAL CONSTRUCTION JOINTS SHALL BE LOCATED
AT MAXIMUM SPACING OF 40 Et., AT LEAST 4 FT. FROM ANY SUPPORTING OR
INTERSECTING WALL OR BUTTRESS, OR ANY WALL OPENING.
14. HORIZONTAL CONSTRUCTION JOINTS WILL NOT BE PERMITTED EXCEPT WHERE
NOTED ON PLANS OR SHOWN AND ACCEPt'ED ON SHOP DRAWINGS.
GENERAL NOTES FRAMING NOTES
CON~RVA'TION CO(~, Ah~ LOCAL AUTHORIZES DWI~R 2, ~.,~ A~E~KrHNG TO ~ APA ~T~. EX~ [ 5/8' ~L E~T~ ~ ~LL ~ ~LVA~ED.
~ 28 DAY ST~TH ~ 3~ P~ ~TH~LT~ ~F~K~D~Y~ B~T~pART~N ACC~E~ ~T~ 3 ~FL~i. 3/4' ~TOT~. ~ ~A ~TEDALLGT~-I-FL~E~G
4. ~ ~E ~RS ~ T~ AT ALL ALL ~ ~TE~ ~L ~ R~TAC~D TO T~ ~ATE
L~ ~ T ~L ~ ~D AT FL~
C~TE ~A6S TO BE C~AC3ED TO 05~ A~ O~E P~TIT~ ~ AS ~TED ~ ~
BY T~E ~S, ALL ~A~ TO BE 2E p~~X~A~E~LE~L N. ALLM~TFLEL~TSTO~2~W~I/2'~[
ROOF FRAMING
WALL FRAMING
Bald lng to Joist IToa-nolled~ 2 - ad each end
D EtLINS SHEATHING
WINDOWS - GLAZED Q,PENING
PROTECTION IS REQUIRED FOR ALL GLAZFD AREAS. IN AccORDANCE WITH LARGE MISSILE TEST
ASTM E ISSE AND OF ASTM lESS. CONTRACTOR MAY USE WOOD STRUCTURAL PANELS
IN LIEU DF THE ABOVE MENTIONED WINDOWS. PANEL DETAILS SHALL BE AS FOLLOWS
4/-0"
MAX,'
- ~S - 2 I/2' WOOD
/ SCREWS el2' D.C.
I/2" PLYWOOD ---~ ~ SET IN I" FROM
x~, ~ EDGE OF PANEL
PANEL
?
* LARGER PANELS TO SE
e o o COSTOM DESIGNED.
PAN'ELS TO RE PRECUT TO FIT OVER WINDOWS WITH
HARDWARE PROVIDED, FASTENERS TO SE DESIGNED TO
ALIGN WITH WINDOW JACK POSTS, HEADER * SILL PLATE.
PANELS TO SE MAINTAINED ON SITE·
LABEL LOCATIONS ON EACH PANEL.
Job Date
Elizabeth Thompson. Architect
250 Mercer St. Suite B 806 Title Scale
New York, NY 2! 2-614-7] 80 ~ ~'j'~,L,~T.~'['gJ~ JdD'T't~ ~ ,f,~,
1001 ~ ETAIchitect@nyc.rr.com
C)
Job Date
Elizabeth Thompson. Architect
250 Mercer St, Suite B 806 Title Scale
New York, NY 212-614-7180
10012 ETAI chitect@nyc.rr.com
~bb \VP. FIC'H6¢6~
Job Date
Elizabeth Thompson . Architect ~r/4¢¢~46 6¢,51p,¢t4~ "/,/if;/~
250 Mercer St. Suite B 806 Title Scale
New York. NY 212-614-7180 ~'1~ ~-/~O L.,k -- I¢.L~V, ~ I. AM, p6-r, I/~,,¢ !,.~,~
! 0012 EYArchitect@nyc.rr.cem