Loading...
HomeMy WebLinkAbout35198-ZTown of Southold Annex 54375 Main Road Southold, New York 11971 4/12/2011 CERTIFICATE OF OCCUPANCY No: 34897 Date: 4/12/2011 THIS CERTIFIES that the building ACCESSORY Location of Property: 22745 CR 48 CUTCHOGUE, NY 11935, SCTM #: 473889 Sec/Block/Lot: 84.-1-25.2 Subdivision: Filed Map No. conforms substantially to thc Application for Building Permit heretofore 12/7/2009 pursuant to which Building Permit No. Lot No. filed in this officed dated 35198 dated 12/7/2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory horse barn (personal use only) as applied for per ZBA//5441, dated 3/18/04. The certificate is issued to Grim, Donald & Grim, Jeanne (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED VAutho~ed Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PEPAWIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35198 Z Date DECEMBER 7, 2009 Permission is hereby granted to: DONALD & JEANNE GRIM PO BOX 300 CUTCHOGUE,NY 11935 for : CONSTRUCTION OF AN ACCY. HORSE BAg_N, FOR PERSONAL USE ONLY, PER ZBA APPROVAL # 5441 AS APPLIED FOR. REPLACES EXPIRED BP # 30416 at premises located at 22745 CR 48 County Tax Map No. 473889 Section 084 pursuant to application dated DECEMBER Building Inspector to expire on JUNE CUTCHOGUE Block 0001 Lot No. 025.002 7, 2009 and approved by the 7, 2011. Fee $ 465.00 Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30416 Z Date JUNE 22, 2004 Permission is hereby granted to: DONALD & JEANNE GRIM PO BOX 300 CUTCHOGUE,NY 11935 for : CONSTRUCTION OF AN ACCESSORY HORSE BARN, FOR PERSONAL USE ONLY, PER ZBA APPROVAL #5441 AS APPLIED FOR at premises located at 22745 CR 48 County Tax Map No. 473889 Section 084 pursuant to application dated JANUARY CUTCHOGUE Block 0001 Lot No. 025.002 21, 2003 and approved by the Building Inspector to expire on DECEMBER Fee $ ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29129 Z Date J~/qUARY 28, 2003 Permission is hereby granted to: DONALD & JEAAFNE GRIM PO BOX 3OO CUTCHOGUE,NY 11935 for : CONSTRUCTION OF A FARM ST~/qD AS APPLIED FOR. THIS PERMIT REPLACES BP#25492. at premises located at 22745 CR 48 Colnnty Tax Map No. 473889 Section 084 pursuant to application dated JkNUARY Building Inspector to exq~ire on JULY CUTCHOGUE Block 0001 Lot No. 025.002 28, 2003 and approved by the 28, 2005. Fee $ 150.00 Authc~zed Si~ature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from amhitect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. '~"~,.~-// Old or Pre-existing Building: New Construction: Location of Property: House No. Street Owner orOwners oferoperty: ~L/~-f -/~ ~'t/~..~/tS/~t~' Suffolk County Tax Map No 1000, Section ~ to/ Block Subdivision Permit No. Health Dept. Approval: Planning Board Approval: Date of Permit. Request for: Temp/~ary Certificate Fee Suhmitted: $ __~~ (check one) Lot c>~,ff~-~ Filed Map. Lot: Applicant: Underwriters Approval: / / Final Certificate: Y (check one) Appl~aoi Signature P,C. February 28, 2011 Mr. Michael Varity Town of Southold Building Department Southold, NY Re: Donald & Jeannie Grim North Road Family Farms, Inc. Accessory Horse Barn Cutchogue, NY MBI Jo1~1280733 Dear Sirs/ I am writing to confirm and advise that the subject job has been completed in substantial compliance to my drawings dated June 15, 2004 per my report fxom the Construction Superintendant. Please be further advised that I have confirmed that the wind bracing, strapping, roof and wall connectors, and framing were installed per my plans. Thank you. Yours truly, PC 765-18~2 BUILDING DEPT. INSPECTION [ ~FOUNDATION 1ST [ [ ] FOUNDATION 2ND [ [ ] FRAMING [ [ ] FIREPLACE & CHIMNEY ROUGH PLBG. INSULATION FINAL REMARKS: 765-1802 BUILDING DEPT. INSPECTION [ ]FOUNDATION 1ST [ ] ROUGH PLBG. [ ]FOUNDATION 2ND [ ] INSULATION [ ]FRAMING [~FINAL [ ]FIREPLACE&CHIMNEY[ ] FIRE SAFETY INSPECTION REMARKS: ~-~ ~/ DATE INSPECTOR ~--~'~ TOWN OF SOUTHOLD BUILDING DEPT. 765-t802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [~FINAL ~"~/~ ~ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ~~-"~~. ~ DATE ~/~ ~~----INSPECTOR ~'~~~~'~  -~. COMMENTS ,. FOUNDATION (1ST) ' ' ~ ~ · ~ ROUGH FRAMING & "~' ~ ~S~A~ON PER N.Y. ~ STATE ENERGY CODE ~ ~ , TOWN OF $OUTHOLD BUILI}ING DEPARTMENT BUILDING PERMIT APPLICATION CHECKLIST TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ PERMIT NO. Do you have or need the followi~ng//~fore applying? Board of Health /~/..tT / 3 sets of Building Planst P!anning Board approval Survey Check Septic Form Examined Approved Disapproved a/c Expiration APPLICATION FOR BUILDING PERMIT .... ~ Date INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of appI nt or name, if a corporation) (Mailin. addres~k~'applicam) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises .~/~'-/d 2t- \,1 ~//]/O~ (As on the tax roll or latest deed) If applicant is a corporat~///{~gnature of duly authorized officer (Name and title'offcorporate...officer) Plumbers License No. Electricians License No. )~ Other Trade's License No. Locatj~f lar~l on w_ hich progosod .w~rk w.ill be done: Number Street County Tax Map No. J40~0/0~ Section Subdivision /~p//7~ Filed Map No. t~/Z)t L°tLot . 2. State existing use and occupancy of prem.~.dgl~)dt ~u.se/and occupancy of proposed construction: a. Existing use ~d occup~cy b. ~tended use ~d occup~cy 3. NaCre of work (check w~ch applicable): New Building_ ~ Addition Alteration R~oval Demolition Other Work Repair. (Description) 4. Estimated Cost Fee (To be paid on filing this aj~p~zc~tion) 5. If dwelling, number of dwelling uni~. ~///// Number of dwelling units on each floor ~'..~ If garage, number of cars ! ...., ,./~, 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ~ Rear ,_.~, Depth ~, Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front ~ Rear ~--~ .Depth c~ Height Number of Stories 9. Size oflot: Front ~)-~ Rear ~t~~7~ Depth ~Z~ 10. Date of Purchase amc of Former Owner 11. Zone or use district in which premises are situated /~- / 12. Does proposed construction violate any zo/ping law, ordinance or regulation? YES NO / / 13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO 14. Names of Owner ofpremise~P/~J~0~t/~/~-~ZJ%ddress ~/~/~X~) _O~.Z~o~ne Name of Architect ~,J~J/ /fl,~ff ,,/~_ ,.,_C~ Address,kf~'6.)F/tS~-~7/, Phone No_ Name of Contractor/"4~Y"d~ ~i~/~k zc Address/r~/~ // Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE~QUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO b/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) COUNTY OF~Jfs/~//~'S?: ~/d T ~'-ff//~ being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the 0~/~f-'- (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swom to before me this f~ ~--~ day of ~ 200' .~ ~~b~ ~-~ t~X · lie LYNDA M. BOHN NOTARY PUBLIC, State of New York No. 01 BO6020932 OualifJed in Suffolk Count,/ Term Expires March 8, 20 ~ Signatur~t~9~ Applicant FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: January 23, 2003 TO: Donald Grimm PO Box 300 Cutchogue, NY 11935 Please take notice that your application dated January 23, 2003 For permit for construction of an horse barn at Location of property: 22745 Count,/Route 48, Cutchogue County Tax Map No. 1000- Section 84 Blockl Lot 25.2 Is returned herewith and disapproved on the following grounds: The proposed horse barn, on this conforming 7.467 acre parcel in the Agricultural Conservation District, is not permitted pursuant to Article III Section 100-31A.2.b, which states; "The keeping, breeding, raising and training of horses, domestic animals and fowl (except ducks) on lots of 10 acres or more." The property is noted as being 7.467 acres. Total lot coverage, following the proposed construction, will be less than 20 percent. Please be advised that the applicant currently has an expired permit for a farm stand, which does not yet have a certificate of occupancy. If the above referenced variance is issued, the farm stand permit will only be renewed if the property meets the requirements of Chapter 47, 3 (B) which states, "The farm stand must be located on a lot containing five tillable acres of land (excluding an,/ house or agricultural building) owned or leased by the owner of the farm stand." According to certification from architect Garrett Strang, dated February 25, 2003, the proposed construction would leave +/- 5.02 acres of tillable land. ~~]c/ Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: ZBA, File FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL TO: Donald Grimm PO Box 300 Cutchogue, NY 11935 Please take notice that your application dated January 23, 2003 For permit for construction of an horse barn at Location of property: 22745 County Route 48, Cutchogue County Tax Map No. 1000 - Section 84 Blockl Is returned herewith and disapproved on the following grounds: DATE: January 23, 2003 AMENDED: December 19, 2003 Lot 25.2 The proposed horse barn, on this conforming 7.467 acre parcel in the Agricultural Conservation District, is not permitted pursuant to Article III Section 100-31A.2.b, which states; "The keeping, breeding, raising and training of horses, domestic animals and fowl (except ducks) on lots of 10 acres or more." The property is noted as being 7.467 acres. Total lot coverage, following the proposed construction, will be less than 20 percent. Please be advised that the applicant was recently issued a permit for a farm stand, which does not ,/et have a certificate of occupancy. In order for the Building Department to issue that permit, the applicant first had to prove that he had 5 tillable acres of land under the requirements of Chapter 47, 3 (B). It is the Building Department's determination that, since the applicant has already set aside 5.02 acres of lane, only 2.447 acres exist toward the horse barn use. This Notice of Disapproval was amended on December 19~ 2003~ to clarify our determination for the Zoning Board of Appeals. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: ZBA, File t FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL TO: Donald Grimm PO Box 300 Cutchogue, NY 11935 Please take notice that your application dated January 23, 2003 For permit for construction of an horse barn at Location of property: 22745 County Route 48, Cutchogue County Tax Map No. 1000- Section 84 Blockl Is returned herewith and disapproved on the following grounds: DATE: January 23, 2003 AMENDED: December 19, 2003 AMENDED: January 12, 2003 Lot 25.2 The proposed horse barn, on this conforming 7.467 acre parcel in the Agricultural Conservation District, is not permitted pursuant to Article III Section 100-31A.2.b, which states; "The keeping, breeding, raising and training of horses, domestic animals and fowl (except ducks) on lots of 10 acres or more." The property is noted as being 7.467 acres. Total lot coverage, following the proposed construction, will be less than 20 percent. Please be advised that the applicant was recently issued a permit for a farm stand, which does not yet have a certificate of occupancy. In order for the Building Department to issue that permit, the applicant first had to prove that he had 5 tillable acres of land under the requirements of Chapter 47, 3 (B). It is the Building Department's determination that, since the applicant has already set aside 5.02 acres tillable acres of land, only 2.447 acres exist toward the horse barn use. This Notice of Disapproval was amended on December 19~ 2003 and January 12~ 2003~ to clarify our determination for the Zoning Board of Appeals. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: ZBA, File Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 BU T NOTICE ;~OVAL Fax (631) 765-9502 Telephone (631) 765-1802 DATE: January 23, 2003 TO: Donald Grimm PO Box 300 Cutchogue, NY 11935 BUILDING DEPARTMENT TOWN OF SOUTHOLD Please take notice that your application dated January 23, 2003 For permit for construction of an horse barn at Location of property: 22745 County Route 48, Cutchogue County Tax Map No. 1000- Section 84 Blockl Lot 25.2 Is returned herewith and disapproved on the following grounds: The proposed horse barn, on this conforming 7.467 acre parcel in the Agricultural Conservation District, is not permitted pursuant to Article 1II Section 100-31A.2.b, which states; "The keeping, breeding, raising and training of horses, domestic animals and fowl (except ducks) on lots of 10 acres or more." The property is noted as being 7.467 acres. Total lot coverage, following the proposed construction, will be less than 20 percent. Please be advised that the applicant currently has an expired permit for a farm stand, which does not yet have a certificate of occupancy. If the above referenced variance is issued, the farm stand permit will not be renewed and would require its own variance pursuant to Chapter 47, 3 (B) which states, "The farm stand must be located on a lot containing five tillable acres of land (excluding any house or agricultural building) owned or leased by the owner of the farm stand." According to the applicant's site plan, the proposed construction would leave +/- 3.16 acres~f tillable land. ~ {Nj 0,~(/ Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. APPEALS BOARD MEMBERS Ruth D. Oliva, Chairwoman Gerard P. Goehringer Lydia A. Tortora Vincent Orlando James Dinizio, Jr. http://southoldtown.northfork.net Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, NY 11971-0959 Tel. (631) 765-1809 Fax (631) 765-9064 BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF MARCH 18, 2004 ZBA No. 5441 - DONALD GRIM Property Location: 22745 C.R. 48, Cutchogue; Parcel 1000-84-1-25.2. SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, Without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 7.458 acre parcel has frontage along two streets: (a) 685 ft. along the north side of Middle Road, C/R. 48, and (b) 358.06 ft. along the east side of Cox Lane, in Cutchogue. The property is improved with a farm stand and storage structures as shown on the March 3, 2000 survey prepared by Peconic Surveyors, P.C., revised March 11,2004. BASIS OF APPLICATION: Building Department's January 23, 2003 Notice of Disapproval, citing Code Section 100-31A.2, in its denial of a building permit application concerning a proposed horse barn on a 7.467- acre lot instead of the code required 10 acres, after applying five (5) acres of tillable land for the existing farm stand use. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on December 18, 2003 and January 22, 2004, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: Applicant wishes to construct a 30' x 60' horse barn with fenced home corral for family use in conjunction with five (5) tillable acres and the existing farm stand structure. The proposed 30' x 60' horse barn will be 20 feet from the easterly property line, and approximately 220 feet from the front southerly lot line. The applicants confirmed there will be no riding academy or training involved with the keeping of their horses. ADDITIONAL INFORMATION:AMENDED RELIEF: During the January 22, 2004 public hearing, the applicant was requested to furnish a map prepared by a licensed surveyor labeling all areas, including tillable areas, area for horse use, and labeling the use or purpose of other existing structures on the property that were not shown on the architectural site map. On March 12, 2004, the applicant furnished a survey amended March 11, 2004, prepared by John Metzger, Peconic Surveyors, P.C. confirming all uses and labeling the activities, existing structures, and proposed areas on the site. The enclosed fence for the horse corral is proposed at four feet in height, with 5' high posts, shown on the construction sketch with the ZBA date stamp of March 12, 2004. The proposed horse barn will be 28 ft. to the top of the ridge from the natural grade as shown on the construction sketch with the ZBA date stamp of March 12, 2004. Page 2- March 18, 2004 ZBA No. 5441 - Donald Grim CTM 1000-84-1-25,2 at Cutchogue REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the relief requested will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The applicant is proposed a 30' x 60' horse barn and fenced corral for personal family use on their 7.46-acre parcel, with is improved with a farm, farm stand and storage structures. By a strict reading of the code, a horse farm for the purpose of keeping, breeding, raising and training of horses, is required on a lot with a minimum of 10 acres, with or without a principal building. Under Code Section 100-30A1 & 2, a principal building or primary use may be a dwelling or agricultural operations. Under Section 100-31C (8), horses and domestic animals other than household pets, are permitted as an Accessory use, provided that such animals shall not be housed within forty (40) feet of any lot line. Therefore, the keeping of horses for personal use when dedicated to a principal or primary use, such as the applicant's agricultural operations on five (5) tillable acres, is permitted. 2. The benefit sought by the applicant, as applied for, cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance from the code requirement pertaining to the keeping of horses on ten (10) acres. 3. The variance granted herein is not substantial. The applicant has shown the required five (5) acres of tillable land for agricultural operations as a primary use. 4. The difficulty was self-created because when the application was submitted to the Town, the application did not confirm the areas for agricultural operations, and did not show conformity to the code's minimum land area for the keeping of horses for personal use, as applied for. 5. No evidence has been submitted to suggest that a variance in this community of mixed uses (business, industrial, agricultural, and residential uses) will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of this'relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a horse barn with corral, while preserving and protecting the character of'the neighborhood and the health, safety and welfare of the community. Page 3 - March 18, 2004 ZBA No, 5441 - Donald Gdm CTM 1000-84-1-25.2 at Cutchogue RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dinizio, seconded by Member Goehringer, and duly carried, to GRANT the variance as applied for, as shown on the March 3, 2000 survey prepared by Peconic Surveyors, P.C., revised March 11, 2004, and shown on the two construction sketches, stamped received by the ZBA March 12, 2004, SUBJECT to the following CONDITIONS: 1. There shall be staggered (double row) line of evergreens, 4 to 6 ft. in height, for at least 200 linear feet along the south side of the corral area, facing C.R. 48 and at least 60 linear feet along the east side extending from C.R. 48. 2. That the screening buffer of evergreens shall be continuously maintained in good condition by the owner. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer, Orlando, and Dinizio. (Member Tortora was absent.) This ResoLution ~3..~duly adopted (4-0). Ruth D. Oliva, Chairwoman 3/19/04 Approved for Filing APPLICATION TO THE SOUTHOLD TOWN BOARD OF APPEALS Office Notes: __ Filed By: For Office Use Only Date Assigned/Assignment No. Parcel Location: House No. Hamlet SCTM 1000 Section~/ Block o! Lot(s) t,~'t. Lot Size ~.~, ~ Zone District ,~/~ I (WE) APPEAL THE WRITTEN DETERMINATION OF THE BUILDING INSPECTOR Applicant/Owner(s): Mailing Address: Telephone: Authorized Representative: Address: Telephone: Please specify who you wish correspondence tO be mailed to, from the above listed nam.es: [] Applicant3Owner(s) ~Authorized Representative [] Other: WHEILEBY q~HE BUILDING INSPECTOR DENIED AN APPLICATION DATED ~Buiiding Permit [3 Certificate of Occupancy [] Pre-Certificate of Occupancy [] Change of Use [] Permit for As-Bui~i'Consi{nction Other: Provision of the Zoning Ordinance Appealed. Indicate Article, Section, Subsection and paragraph of Zoning Ordin_~.gance by numbers. Do not quote the code. Article Section I00- ~1,~ Subsection ~..,~ . ~'~ =' Type of Appeal. An Appeal is made for: ~ A Variance to the Zoning Code or Zoning Map. [3 A Variance due to lack of access required by New York Town Law-Se'etlon 280~A. t3 Interpretation of the Town Code, Article Section [3 Reversal or Other ., A prior appeal [] has/ii has not been made with respect to this property UNDER Appeal No. Year Page 2 of 3 - Appeal Application Part A: AREA VARIANCE REASONS (attach extra sheet as needed): (1) An undesirable change will not be produced in the CHARACTER of the neighborhood or a detriment to nearby properties, if granted, because: (2) The benefit sought by the applicant CANNOT be achieved by some method feasible for the applicant to pursue, other than an area variance, because: (3) The amount of relief reauested Is not substantial because: (4) The variance will NOT have an adverse effect or impact on the physical or environmental conditions in the neighborhood c~r district because: /_ (5) Has the variance been self-created? ~ Yes, or ( ) No. If not, is the construction exlsflng, as built? [ ] Yes, or (~ No. (6) Additional information about the surrounding topography and building areas that relate to the dlfficul~ In meeting the code rec~ulrements: (attach extra sheet as needed) This is the MINIMUM that Is necessary and adequate, and at the same time preserves and protects the character of the neighborhood and the health, safely, and welfare of the community. ( } Check this box and complete PART B, Questions on next page to apply USE VARIANCE STANDARDS. (Please consult your aflorney.) Otherwise, please proceed to the sl.qnafure and notary area below. Sworn to be, l,ore me this /~g'~ay of .',~..,f~'.~,?/,~..~., 200S. / (Notary Public) ~/ Slgnatum-ol~pellant or Authorized ~gent (Agent must submit Authorization from Owner) Barbara A. Strang NOTARY PUBLIC, New York No. 4730095 Qualified - Suffolk County Comm. Expires July 31, ~ o~,/_ ZBA App 9~30/02 QUESTIONNAIRE FOR FILING WITH YOUR Z.B.A. APPLICATION Is the subject premises listed on the real estate market for sale? 0 Yes ! No Are there any proposals to change or alter land contours? 0 Yes · No 1) Are there any areas that contain wetland grasses? ~o 2) Are the wetland areas shown on the map submitted with this application? ~J ~ 3) Is the property bulk headed between the wetlands area and the upland building area? If your property contains weflm~ds or pond ~re,as, have you contacted fl~¢ o?/hce of the Town Trustees for its determination of jurisdiction? ~///A Is there a depression or sloping elevation near the area of proposed construction at or below five feet above mean sea level? /~t/& (If not applicable, state "n/a".) Are there any patios, concrete barriers, bulkheads or fences that exist and are not shown on the survey map that you are submitting? ~oo~O~ (If none exist, please sta~e "none".) Do If yes, please submit a copy of your building permit and map as approved by the Building Department. If none, please state. Do you or any co-owner also own other land close to this parcel? where or submit copies of deeds. If yes, please explain Please list present usmor operations conducted at this ~6~};¢. ,,Qr~)&~. ~ and proposeduse~~'~O ~orized Signature and Date APPLICANT TRANSACTIONAL DISCLOSURE FORM The Town of Southold's Code of Ethics prohibits conflict~ of interest on the part of Town officers and employees. The purpose of this form is to oro¥ide inform~,tion, which can aleg ~he Town of possible conflicts of interest and allow it to take whatever action is neeessar~ to avoid same. YOURNAME: (Last name, first name, middle initial, unless you are applying in the name of someone else or other entity, such as a company. If so, indicate the other person or company name.) NATURE OF APPLICATION: (Check all that apply.) Tax Grievance Variance ~ Change of Zone Approval of Plat Exemption from Plat or Official Map Other If "Other", name the activity: Do you personally, (or through your company, spouse, sibling, parent, or child) have a relationship with any officer or employee of the Town of Southold? "Relationship" includes by blood, marriage, or business interest. "Business interest" means a business, including a partnership, in which the Town officer or employee has even a partial ownorship of (or employment by) a corporation in which the Town officer or employee own~ more than 5% of the shares. NO If you answered "YES", complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold: Title or position of that person: Describe that relationship between yourself (the applicant) and the Town officer or employee. Either check the appropriate tine A through D (below) and/or describe the relationship in the space provided. The Town officer or employee or his or her spouse, sibling, parent, or child is (check all that apply): A) the owner of greater than 5% of the shares of the corporate stock of the applicant (when the applicant is a corporation); B) the legal or beneficial owner of any interest in a non-corporate entity (when the applicant is not a qorporation); C) an officer, director, partner, or employee of the applicant; or . D) the actual applicant. DESCRIPTION OF RELATIoNsHIP 3h Submitted this/~,~4 da, of, i~ Signature: ~[,)~ ~ ~ Print Nmne: bO~*~l~ iPROJECT I.D. NUMBER 617.20 Appendix C * State ,Environmental Quality Review SHORT ENVIRONMENTAL ASSESSMENT FORM For UNLISTED ACTIONS Only PART I--PROJECT INFORMATION (To be completed by Applicant or Project sponsor) SEQR PROJECT LOCATION= 4. PRECISE LOCATION (Stree~ address and road Inlersectlons, prominent landmarks, etc., or provide map) 5. IS PROPOSED ACTION: ~New [] Expansion [] Modlllcation/&lteratton 7. AMOUNT OF ~ND AFFECTED: 8. ~LL PRO~SEO A~ION ~MPLY ~TH ~[STING ZONING OR OTHER ~ISTING ~ND USE RESTRICTIONS? ~ Yes ~ No It No, des~l~ briefly e, W~T IS PR~ ~O USE iN VI~N~ OF PR~ECT? 10. ~ A~ON.INVOLVE A PERMIT APPROVA~ OR ~NOING, NOW OR ULTIMATELY FROM ANY OTHER GOVE~M~AL AGEN~ (FEDE~ STATE OR L~? ~ Yes ~ No If yes, list ag~a) ~ ~lU~pp~ill 11. ~ A~ ~PE~ OF ~E A~ON HA~ A ~$gY VAUD P~M~ OR APPROVAL~ ~ Yes ~No If y~, list ~ge~ n~ and ~Ueppr~sl . 12. AS A RESULT OF PRO~SED A~ION WILL ~IS~N~ P~MnlAPPROVAL REQUIRE MOOIFICATION? O Y., O ,o ~/~ Signature: I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE TO THE BEST OF MY KNOWLEDGE If the act[on Is In the Coastal Area, and you are a state agenoy, complete the Coastal Assessment Form before proceeding with this assessment OVER 1 ,,] /~ ~ ~ .. ~,/./-;<aTOWN OWNER ,FORMER OWNER OF SOUTHOLD PROPERTY RE¢ VI LLAGE :ORD rES. SEAS. LAND IMP. VL TOTAL CARD SUB. LOT FARM COMM· CB. MISC. Mkt. Value DATE REMARKS TYPE OF BUILDING Zz o~ /R aa FARM tillable I 'illable 2 'illable 3 Voodland ,wampland :rushland {ouse Plot 'oral Acre 0 oo Value Per Ac re Value FRONTAGE ON WATER FRONTAGE ON ROAD DEPTH BULKHEAD DOCK ~OR 84-1-25.3 02/02 ,. Bldg. 1Foundation Bath Dinette ,tension [Basement Floors K. Ctension Ext. Walls Interior Finish LR, <tension Fire Place Heat DR. Type Roof Rooms 1st Floor BR. )rch I~creation Room Rooms 2nd Floor FIN. B. )rch Dormer reezeway Drivewa'¥ ~ ~'o~ zlo,~O~= 32o0 'otio B. otal /~oo I_Iff~BER SPEC! FICATION§ Top Chord 2XIO SYP NI]. ! KDI9 I.ower Cl~ord 2X8 §YP M§R 1950 Webs 2X4 SYP ND. 1 KD1 9 {RUSS PLATE DATA - (ANSI/TP! 1-1995) ~0 GA, |8 GA. Te~$1(e Votue O* 403 pti 6i0 pit 90° 403 pll 610 pll 30' 259 pti 60' 315 go' 276 pll 120' 261 pti 4t0 361 410 403 pll 363 TC3 6x9 PI. 1, 7E6 1. 5E6 1. 7E6 TCLL TCBL LCDL Req'd Truss Load - LDADS ~6psF Load duration Factor ~ psF ~ psF Truss Design Load - ,390 plf ~ psf at-/0$~OC. = 4~00 plf =1,15 MEMBER FORCE TABLE Member Forces Member Stre Bending Axiai Bending A Member CSI (in-tbs) (tbs) (psi) ( TCI TC2 TC3 LCt LC2 LC3 W1 W2 ~3 W4 g'~,, W5 !~ w2 PI. ~ W~ 16x9 PI. 9x9 6x9 I 18 Go. PI. PI. LC5 2xBx16' LC2 3'3-3 8'3-3/16" 14'10-1/2" ,934 -16477. -10689, -770, 3 -' , 891 15841, -10094. 740, G - 650 9242. -9208, 432.1 - 810 7163. 9742. 545.1 791 7163. 9418, 545.1 505 -1909. 7577. -145. 3 058 O. -543. .0 - 599 O, -2153, .O - 036 O, 287. .0 371 O, 2354. .0 028 O, 90, .0 12 TEl 2-16x8 PI. 18 Go / 13x8 PI. 18 LC1 Truss Reocti on, 5711, 875 tbs, ICCP 30' COMM, SC TRUSS Morton Buildings '1 I $I:PE EL.EVAT~4~ 16'10 1/2" ffl RIB ROOf STEE 2x4 TRUSS CRAD£ TO 372/374 STYLE 29'9" NAILER PROTECTIVE LIN BASE ~RADE ' 372/374-~,~-¥',L~_:' ?LAIN END_., WIDE BUILDING 7'741/2' w · 7'3' 572/374 STYLE END W/ 15' DOOR FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL TO: Donald Grimm PO Box 300 ........ Cutchogue, NY 11935 ...... Please take notice that your application dated January 23, 2003 DATE: January23, 2003 For permit for construction of an horse barn at Location of property: 22745 County l~oute 48, Cutchogue County Tax Map No. 1000, Section 84 Blockl Lot 25.2 Is returned herewith and disapproved on the following grounds: The propos~ed~ rse am, on this conforming 7.467 acre par el in the Agricultural Conservation District, is not permitted pursuant to Article III Section 100-31A.2.b, which states; "The keeping, breeding, raising and training of horses, domestic animals and fowl (except ducks) on lots of 10 acres or more." The property is noted as being 7.467 acres. ". ' ' ''~ ':" '" T~fal lot coverage, following the proposed construction, will be less than 20 percent Alease be advised that the applicant currently has an expired permit for a farm stand, which does not yet have a certificate of occupancy, lfthe above referenced variance is issued, the farm stand permit will only be renewed if the property meets thc requirements of Chapter 47, 3 03) which states, ."The farm stand must be located on a lot containin~ five tillable acres of land (excluding any f house or agricultural building) owned or leased by'~e owner of the farm stand." ,,According to certification from architect Garrett Strang, dated February 25, 2003, the proposed construction would leave +/- 5.02 acres of tillable land. ~~...~~~...._~ Authorized Signature _N. ot to Apphcant: Any change or deviation to the abo~e, referenced application, may require further review by the Southold Town Building Department· APPEALS BOARD MEMBERS Ruth D. Oliva, Chairwoman Gerard P. Goehringer Lydia A. Tortora Vincent Orlando James Dinizio, Jr. http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD January 9, 2004 Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, NY 11971-0959 Tel. (63'1) 765-1809 Fax 765-9064 By Fax and Regular Mail Mr. Garrett Strang, R.A. P.O. Box 1412 Southold, NY 11971 Re: ZBA #5441 - January 22, 2004 Public Hearing (Grim Property) Dear Mr. Strang: The Board reviewed the December 19, 2003 amended Notice of Disapproval issued by the Building Department, and requests seven (7) prints of an updated survey or site map which will show the tillable acreage applied to the farm stand use, the acreage applied toward the horse barn use, and remaining area remaining. If there are structures or berms that will be moved or altered to provide tillable areas, please also label this information on the maps. Thank you. Very truly yours, cc: Building Department (Attn: D. Rallis) ~ Ruth D. Oliva Chairwoman Town Hall, 53095 Main Road P.O. Box t 179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765 1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD September 14th, 2006 Donald & Jeanne Grim P.O. Box 300 Cutchogue, N.Y. 11935 RE: 22745 Cr 48 (Horse Barn) S.C.T.M. # 84 1 25 2 Dear Mr.& Mrs. Grim, Please be advised that your Building Permit # 30416 issued June 22na 2004 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $465.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (63 l) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTItOLD March 26th, 2007 Donald & Jeanne Grim P.O. Box 300 Cutchogue, N.Y. 11935 SECOND NOTICE RE: 22745 CR 48 (horse barn) SCTM: 84 1 25 2 Dear Mr. Grim, Please be advised that your Building Permit #30416 issued June 22nd 2004 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of $465.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631 ) 765-9502 Telephone (631 ) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD March 24th, 2008 FINAL NOTICE Donald & Jeanne Grim P.O. Box 300 Cutchogue, N. Y. 11935 RE: 22745 CR 48 S.C.T.M. # 84. -1-25.2 Dear Mr. & Mrs. Grim Please be advised that your Building Permit # 29129 issued January 28th, 2003 and Building Permit # 30416 issued June 22"a 2004 have expired According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit's, please submit a fee of $615.00; at that time we can schedule an inspection by one of our Building Inspector's. lf you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. BP# 29129 - FARM STAND - $150.00 BP# 30416-HORSE BARN- $ 465.00 Town Hall Annex 54375 Main Road P.O. Box 1179 Somhold~ New York 11971-0959 Telephone (631 ) 765- 1802 Fax (631 ) 765 9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD November 9th, 2009 Donald & ~Tcanne Grimm P.O. Box 300 Cutchogue, N.Y. 11935 I~e: 22745 Clt 48/Violation $CTM# 1000-84.-1-25.2 To Whom This May Concern: Your BUILblN~ PERMIT # 2c)12~} issued ~Tanua~y 28th, 2002 for construction of a FARM STAND and BUTLDTNF~ PERMIT # 3227§ issued ~UNE 22N~, 2004 for construction of a Horse Barn have been referred to me because you have not responded to requests to obtain your certificate of occupancy as required by Southold Town code. Pursuant to 144-:1§A, of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building l'nspector." Therefore, you have ten days from the receipt of this letter to submit a check made out to the Town of Southold in the amount of $6:1§.00: to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Damon Rallis, Zoning Inspector Southold Building Department ,,~ ..... ~ :'~,~ ~_ ~_~.~_ GARRETT A. STRANG architect ..... -:. ~,.~.~.~.. ~- P, 0. BOX 1412 Sout hold N.Y. d1971 516- 765 - 5455 MORTON BUILDINGS GENERAL SPECIFICATIONS LAMINATED COLUMNS - NO. 1 OR SETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S COLUMNS NAILED 8" O,C. STAGGERED ON EACH SIDE WITH 4" NAILS. ANCHORED ON CONCRETE - COLUMNS ARE ATTACHED TO CONCRETE BY USE OF 1/4" H,R. STEEL COLUMN SOCKETS. EACH SOCKET IS FASTENED TO THE CONCRETE BY TWO 1/2" DIA, x 8" PLATED ANCHOR BOLTS AND COLUMN IS FASTENED TO SOCKET BY FOUR 1/2 x 2 1/2" LAG SCREWS AND FOUR 20d R,S, NAILS. BASEBOARDS - BASEBOARDS ARE NO, 2 OR BETTER SOUTHERN YELLOW PINE 2"x4" S2S AND CENTER MATCHED, PRESSURE TREATED TO NET RETENTION OF .6 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE TYPE, IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS' ASSOCIATION SPECIFICATION C2. ONE ROW IS FURNISHED FOR BUILDING ON A LEVEL SITE, FRAMING LUMBER -SIDE NAILERS ARE 2"x4" S4S OR 2"xB" SPF NO.2 OR BETTER SPACED APPROXIMATELY 50" O.C, WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS, ROOF PURLINS ARE 2"x4" S4S NO, 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O,C, ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER. ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 OAUOE GALVANIZED STEEL TRUSS PLATES AS REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU, TRUSSES ARE DESIGNED IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. SIDING PANELS (KyNAR 500/HYLAR 5000) - 0.019" MIN,, 090 GALVANIZED OR AZ55 OALVALUME, WITH AN ADDITIONAL BAKED-ON KYNAR 500/HYLAR 5000 FINISH WITH A NOMINAL 1 MIL PAINT THICKNESS ON EXTERIOR, ROOFING PANELS (FLUOROFLEX 2000 (TM)) -0.019" MIN., AZ55 BALVALUME WITH AN ADDITIONAL BAKED-ON THICK POLYURETHANE PRIMER AND KYNAR 500/HYLAR 5000 TOPCOAT WITH A TOTAL MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR, TRIM -DIE-FORMED TRIM OF 0.019" MIN,, 090 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, RIDGES, CORNERS, BASE, WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. GUTTERS - 5" R-STYLE, .OZO HIGH TENSILE ALUMINUM CUTTER, KYNAR 500/HYLAR 5000 FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDING. ADDITIONAL NOTES 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED AS PART OF THESE DRAWINGS. 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE PROVIDED BY OWNER. STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, AND CORRIDORS. 5.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECiFrC JOB DRAWINGS OR SUPPLEMENTAL iNFORMATION. 5.) KYNAR 500 IS A REGISTERED TRADFMARK OF ELF ATOCHEM NORTN AMERICA, HYLAR 5000 IS A TRADEMARK OF AUSIMONT, USA. CS2x4WFK 10-00 Al. UNDERWRITERS CERTIFICATE REQUIRED APRROVF. D AS NOTED NOTfFY gull '~ ~RTMENT AT 765-1802 8AN~ 4 FOR THE FOLLOWING INBPE ,,.NS: 1. FOUNDATID' DO NOT PROCEED WITH FRAr ',',!'~ UNTIL SURVEY OF FOU . ATION LOCATION HA5 B~:EN APPROVED. NOTE: FLOOD ZONE, COMPLY W~TH CHAPTER "46" FLOOD DAMAGE PREVENTION SOUTHOLD TOWN ~3DE. THESE PLANS REFLECT AN ENGINEERED DESIGN (NOT A PRESCRIPTIVE DESIGN) THAT SATIFIES THE STRUCTURAL REQUIREMENTS OF THE BUILDING CODE OF NEW YORK STATE. COMPLY W.T. AU. CO.ES NEW YORK STAT & TOW. As REOU RED c om s ~UILDING IDESIGN CRITERIA USE GROUP CONSTRUCTION ]rYPE VB LIVE ROOF LOAD DESIGN~ 38 PSF WIND SPEED (V31s) 120 MPH FLOOR LOAD 125 PSF FLOOR AREA 4230 SF GROUND SNOW bOAD 45 PSF *SNOW LOAD CALCULATIONS Ps = 0.7 x Ce x I x Pg x Ct x Cs Ce = SNOW EXPOSURE FACTOR = 1.0 I = IMPORTANCE FACTOR = 1.0 Pg = GROUND SNOW LOAD = 70 P.S.F. Ct = THERMAL FACTOR = 1.2 Cs = ROOF SLOPE FACTOR = 0.94 TYPICAL LUMBER SPECIFICATIONS - 1997 NDS SIZE DESCRIPTION BENDING VALUE Fb 2"x4" NO1&2 SPF 1313 PSI 2"x4" 2100f MSR SPF 2100 2"x6" NO.1&2 SPF 1158 PSt 2"x6" NO, 1 GYP 1650 PSI 2"xB" NO, 1 GYP 1500 PSI 2"x10" NO, 1 GYP 1300 PSI 2"x12" NO, 1 GYP 1250 PSI ALL lgBOf MSR GYP 1950 PSI 1 1/2"x18" LAMINATED VENEER LUMBER 2800 PSi 3 1/2"x15" GLU-LAM 1650 PSI ~ 1/4"x16 1/2" GLU-LAM 2400 PSI ~/4'×19 I/2' GLU-LAM 2400 PSI Ps = 0.7 x.,O,g x L/ii l! UNI,AW, UL ITHOUT OERTtFICATE OocuPAN¢¥ NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. D.8 x 45 x 1.2 x 0.94 = 36 psi RETAIN STORM WATER RUNOFF PURSUANT TO SECTION 45-100 OF THE TOWN CODE. jOFFICE: CUTCHOGUE, NY/ oB N%_o 33 d BY: JK823 DATE: 6/]0/04 CHECKED B DATE: 6/]0/04 REVISED DATE: REVISED DATE: REVISED DATE: REVISED DATE: 2804 SHEET rNDEX SHEET # DESCRIPTION G1 OF 61 SPECIFICATIONS & SHEET INDEX S1 OF SS COLUMN PLAN S2 OF S5 ELEVATIONS S3 OF S5 SECTIONS S4 OF S5 ROOF BRACING LAYOUT &: FASTENING SCHEDULE S5 OF SS TRUSS DRAWING &: DETAILS I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN THIS BUILDING WAS PREPARED BY ME OR U~ DIRECT SUPERVISION AND THA' A DUE REGISTERED PROFESSIONAL RONALD L. ~ DATE:O~,IG WARNING: IT Is A ~JIOLATION OF NYS LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF THE LICENSED ARCHITECT OR LICENSED ENGINEER TO ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM. AS NOTED SHEET NO, GloE G1 TRUSS DIMENSIONS 7'-4 I I I 7'-3 .3/4" [ I I T T-3 3/4" 16' COLUMN PLAN SCALE: 7'-6" [ 7'-6" [ 7'-5 1/4" ,~ LC3 "l 7'-4 1/2" i 7'-5 I/4' -- 1'-0" VENTED SIDEWALL OVERHANGS NON-VENTED ENOWALL OVERHANGS 29'-9" 22'-4 1/2" 20'-7 1/2" 9'-1 1/2" 7'-4 1/2" CUTCHOGUE, NY ~JOB NO, 128-0755 '~RAWN BY: JK823 DATE: 6/10/04 CHECKED BY: DATE: REVISED DATE: REVISED DATE: REVISED DATE: ~EVISED DATE: COLUMN PLAN LEGEND u - 5-2"x6" LAMINATED COLUMN LOCATfON ~; - 4-2"x6" LAMINATED COLUMN LOCATION []- (2) ,3068 PLAIN FLAT SLAB FIBERSTEEL WALKDOORS W/LOCKSETS 2N- (4) 4429 PLAIN VINYL SLIDING HAYFIELD WINDOWS (~)- 12'x16' WOOD FRAME DOUBLE SLIDING END DOOR W/WEATHERSEAL (~}- 12'x14' OVERHEAD DOOR~ ~- 30' S.C. TRUSSES @ 7'~6" O,C. TYPICAL CONTINUOUS 2"x4" LOWER CHORD TRUSS TIES AND 2"x6" DIAGONAL END BRACING APPROXIMATELY 7'-6" O.C, TYPICAL ~:>- 3/4" OSB DOUBLE SHEARWALL (SEE SHEET S4 OF S4 FOR DETAILS) NOTE: +IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY MORTON BUILDINGS, INC, OR ~40RTON BUILD,NOS' SUBCONTRACTORS AND ARE THE OWNERS RESPONSIBILITY, ROUGH OPENING SCHEDULE UNIT SYMBOL I FROM LEGEND WIDTH HEIGHT [] ,38 1/4" 81" z~ 52 1/4 35 5/8 ISCALE: AS NOTED s% (ZONE (ZONE (ZONE (ZONE WIDE (ZONES 2 & 3) 3'-0" WIDE (ZONES 2 '1 5" O.D, BUTTERS HI-RIB STEEL T#21 CORNER TRIM TRANSITION TRIM STEEL WAINSCOT T#167 BASE TRIM W/T#1a2 3'- 0" WIDE (ZONE 5) 54"--0" WiDE (ZONE 4) EAST ELEVATION 3'-g" WIDE (ZONE 5) 3'-0" WIDE- (ZONE 5) (ZONE (ZONE 5) (ZONE 2) (ZONE 3) (ZONES 2 & 3) 5" O.G, GUTTERS HI-RIB STEEL CORNER TRIM -- T#167 TRANSITION TRIM -- HI-RIB STEEL WAINSCOT T#167 BASE TRIM W/T#1g2 (ZONE 5) 54"-0" WIDE (ZONE 4) WEST ELEVATION 5'-0" WIDE (ZONE B) 3'-0" WLDE (ZONES 2 & 5) [ 3'-0" WIDE© (ZONE 5) ¢1-- -'1 WIDE (ZONES 2 & -- T#16 GABLE TRIM Hi-RIB STEEL T#21 CORNER TRIM 24'-0" WIDE (ZONE 4) NORTH ELEVATION T#167 TRANSITION TRIM -- HI-RI8 STEEL WAINSCOT -- T#167 BASE TRIM W/T#192 -- 3'-0" WIDE (ZONE 5) 3'-0" WIDE (ZONES 2 & T#16 GABLE TRIM HI-RIB STEEL T#21 CORNER TRiM 24'-0" WIDE (ZONE 4) SOUTH ELEVATION T#167 TRANSITION TRIM HI-RIB STEEL WAINSCOT T#167 BASE TRIM W/T#m2 -- 3' 0" WIDE (ZONE 5) IIFFICE: OB NoC~TCHOCUE' NY 128-0733 i , i_4 /"-DRAWN By: JE 823 DATE: 6/10/04 CHECKED BY: DATE: REVISED DATE: REVISED DATE: REVISED DATE: ~EVISED DATE: SCALE: 8~ 16' I SCALE: ,5,8 NOTED SHEET NO. S2 S5 (~_) 7/1B" OSB (~)2"x4" PURLINS @ 19,2" (NO, 2 SPF) 2"x4" BEV. PURL WIRE MESH ~ T#178 -- 2"x6" BEV. 5" 0,0, CUTTERS T#144 & 146 FASCIA TRIM-- HI-RIB/SOFFIT 2"x6" OVERHANC NAILER FF2000 HI-RIB ,30' S,C, TRUSS 1/2"x5 1/2" M, BOLTS & 20d R.S, NAILS HI-RIB STEEL (KYNAR)(~) 4-2"x6" LAMINATED COLUMN NAILERS @ 24" O,C.(~) 2100f MSR SPF TOP OF CONCRETE WALL TO HEEL FINISH GRADE~ BABE TRIM W/T#192 1 1/2"xl 1/2" VERTICAL BLOCKING AT COLUMN LOCATION ~167 TRANSITION TRIM NOTCHED NAILER(~) STEEL WAINSCOT (KYNAR) OSB PROTECTIVE LINER(~) TREATED SPLASHBOARD W/(~) PRECOMPRESSED ULTRA-SEAL TALL COLUMN SOCKET W/ III v2,.x7 M. BOLTS 20d R,S. NAILS (2) 1/2"x8" PLATED ANCHOR BOLTS 4" CONCRETE FLOOR~ 8** SIDEWALL --'4" MINIMUM COMPACTED GRANULAR BASE'~ CONCRETE FOUNDATION WALL· VERTICAL REINF, #4 REBARS SET IN FTG, NOT TO EXCEED 2' 0,C,¢ MIN, HORIZONTAL REINF. 2-#4 REBARS, 1 AT 5" FROM TOP, 1 AT 5" FROM BOTTOM, AND SO NO BARS ARE MORE THAN 2' APART· FYPICAL FOOTING W/ 2-#4 REBARS UNLESS SPECIFIED OTHERWISE'I, SECTION A-A SCALE: 1/2"= 1'-0' NOTE~-. · IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY NORTON BUILDINGS, INC. OR MORTON BUILDINGS' SUBCONTRACTORS AND ARE THE OWNERS RESPONSIBILrTY. (2) 2"x6" 2"x6" NAILER 2"x6" BLOCK ~ T# 124 .~ T# 12[ I 2"x2" BLOCK T# 151 T# 154 2"x5" JAMB (BEYOND; BOTTOM 2' TREATED) (3) 2"x6" JAMB COLUMN (BEYOND) 2"x6" TRACK BLOCK (BEYOND; BOTTOM 2' TREATED) OHO HEADER SCALE: 1"= 1'-0" (~)2"x4" PURLINS ¢ 19.2" 2"x4" BLOCK BETWEEN PURLINS T#16 GABLE TRIM 2"x6" BEV ~ T#194 TRIM ~ SOFFIT HI-RIB KYNAR HI-RIB STEEL 2- 2"x6" E.C.E, OSB SHEATHING (~) R.W. OR / / 2'x6" DIAGONAL BRAG / / FASTENED TO COLUMN W/ (4) 16d R,S, NAILS ..... ~"%~2"×4" DES ABEL. 2"x6" NAILER :1) 2Od R,S, NAIL THROUGH STRAP & INTO BRACE ID BRACE STRAP W/ PRE-PUNCHED HOLES (BEND TO FIT) (3) ]1/2" R,S. NAILS TOP OF CONCRETE WALL TO HEEL NOTE; THIS SECTION IS THE SAME AS SECTION A-A EXCEPT FOR THE ITEMS AS NOTED. FINISH GRADE% SIDEWALL SECTION B-B SCALE: 1/2"= f-o" I +_-~3o' s,c. TRUSS (ABOVE) J J 4-2"x6" LAM, COLUMN I ; / ~'IrR~ /~(2) 1/2"x5 1/2" M. BOLTS 2"x4" NAILERS~T KYNAR HI-RIB STEEL DETAIL SCALE: 1 1/2"=1'-0" KYNAR HI-RrB STEEL (2) 2"x6" UPRIGHT 2"x10" TRACK GIRT 2"x8" HEADERS L r 152 1(-3" GRADE TO BOTTOM OF 2"x6" BLOCK SECTION C-C T#71 TRACK 51M ,3"x4" TRACK 1/2"x2" BLOCK & T#74. T#171 JAMB TRIM 2"x3" JAMB (BEYOND;- BOTTOM 2' TREATED) 16'-0" TO TOP OF CONCRETE 3-2"x6'" JAMB COLUMN BEYOND SLIDING DOOR HEADER SECTION D-D SCALE: 1 "= 1'-0" IIFFICE: OB NO~UTCHOGUE' NY 128-0735 BY: JK 823 DATE: 6/10/04 CHECKED BY: DATE: REVISED DATE: REVISED DATE: REVISED DATE: REVISED DATE: I SCALE: AS NOTED SHEET NO, S3 GE S5 ROOF BRACING LAYOUT SCALE: 2' 8~ 16' _- 50' S.C. TRUSSES @ 7'-6" O,C. CONTINUOUS 2"x4" LOWER CHORD TRUSS TIES @ 5'-9" O.C. <~)- 2"x6" DIAGONAL END BRACING @ 7'-6" O.C, ROOF STRUCTURE FASTENING SCHEDULE (~) VENT-A-RIDGE TO RIDGE BASE TRIM #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8" o.c, (~) RIDGE BASE TRIM TO 2"x4" PURLINS 0.135" x 2-1/4" RUBBER WASHER RING SHANK GALVANIZED NAIL AT EVERY HI-RIB (1'-0" o.c,) (~ HI-RIB STEEL STITCHING #gx 1' STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS JN LAP RIBS BETWE(~,N_oP,,URLINS (~) HI-RIB STEEL TO 2"x4" PURLINS (@ EDGE STRIPS) #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RI8 o.c,) (~) HI-RIB STEEL TO 2"x4" PURLINS (© INTERIOR ZONES) #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" o.c,) (~ 20 9a. GALVANIZED PURLIN CONNECTORS #9 x 1" TRU-GRIP SCREWS ~.~ 2"x4" PURLINS TO TRUSS 0,200" x 6" (6Od) RING SHANK NAILS IN PRE-DRILLED HOLE ~ 0,115 x2 5/8" GUN NAIL '~ 7/16" OSB ROOF SHEATHING ,, ~ ~ (4) 0,151 (Sd) x 1-1/2" RING SHANK NAILS ~ ~ING SHANK NAILS (~) RT4 HURRICANE ANCHOR TO TRUSS .... (2) 1"~""~2"x5 1/2" MACHINE BOLTS (~ 50' STRAIGHT CHORD TRUSS TO COLUMN (4) 0.177" x 4" (2Od) RING SHANK NAILS WALL FRAMING FASTENING SCHEDULE (~) GALVANIZED STEEL COLUMN SOCKET TO CONCRETE (2) 1/2" PLATED ANCHOR BOLTS (~) GALVANIZED STEEL COLUMN SOCKET TO COLUMN 20d R.S, NAILS (~) 2"x8' SPLASHBOARD TO COLUMN (4) 0.177" x 4" (2Od) GALVANIZED RING SHANK NAILS © SPLICE/ (3) 0,177" x 4" (2Od) CALVANINED RING SHANK NAILS @ STANDARD CONNECTION (~) 2"x6" NOTCHED NAILER TO COLUMN (4) 0,148" x 5-1/2" (16d) NAILS @ SPLICE/ (5) 0,148" x 3-1/2" (16d) NAILS @ STANDARD CONNECTION (~) 7/16" OSB TO SPLASHBOARD & NOTCHED NAILER 0.106" x 1-1/4" ASBESTOS SIDING NAILS (~) 2'x4" NAILER TO COLUMN (4) 0,148" x 5-1/2" (16d)~RING SHANK NAILS @ SPLICE/ (5) 0.148" x 5-1/2" (16d) RING SHANK NAILS @ STANDARD CONNECTION --"~---~.____.____. ~X 4" (2Od) RING~SHANK HAILS (~) ~ PURLIN TO END TRUSS -- 0.200" x 6" (6Od) RING SHANK~NAILS IN PRE DRILLED HOLE '-~ RT4 BURRICA""~NE ANCHOR TO'--'"~ND TRUSS (4) 0.151 (Sd) x 1-1/2" RING SHANK NAILS ~ #9 x 2 ~ ~ c.c.) ~ HI-RIB STEEL TO HAILERS SOFFIT T~ WALL ~ INSERTED IN PRE-FORMED SLOT IN SOFFIT/HI-RIB CAP SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE (~ ~DOUBLE 5/4" OSB SHEARWALL T FIRST LAYER OSB TO PERIMETER BLOCKS/ FRAMING ~G SHANK GUN NAILS © 5" c.c. --~ -- 2-3/8" (8d) RING SHANK GUN NAILS @ 6" ~ FIRST LAYER OSB TO INTERMED. BLOCKS/ FRAMING 0,113" x c.c. ~) SECOND LAYER OSB TO PERIM, BLOCKS/ FRAMING 0.151" x 2-7/8" (1Od) RING SHANK GUN NAILS @ 3" o.c. (~) SECOND LAYER OSB TO INTERMED, BLOCKS/ FRAMING 0,151" x 2-7/8" (1Od) RING SRANK GUN NAILS @ 6" o,c. (~ ~BACKER BLOCKS TO END FRAME 0,1,31" x 2-7/8" (1Od) RING SHANK GUN NAILS @ 5" o,c. IiFFICE:cuTCHOGUE, NY 1 OB N(~8_0755 J ~DRAWN BY: ~I~T~ §23 · DATE: 6/10/04 CHECKED BY: DATE: REVISED DATE: REViSEg DATE: REVISED DATE: ~EVISED DATE: · I SCALE: AS NOTED ) SHEET NO. S4 oF S5 TRUSS DESIGN SPECIFICATION: Truss has been designed by computer using the Purdue Plane Structure Anelyzer lAW current stenderds <]nd specifications of recognized engineering pdncipres, Trusses ore menufectured by Morton Bufld~ngs, inc, LUMBER SPECIFICATION (1997 NDE for Wood Construction): Lower Chord -- 1950f - 1.5E MSR Southern Pine Top Chord --- No. 1 K.D. - 19 Southern Pine Web Members -- No. 1 K.D. - 19 Southern Pine TRUSS PLATE SPECIFICATION (ICBO Evaluetion Report No. 2929): ASTbl A-653, Orede A 20 Ge. end 18 Ga. where noted, golvoflized steel Morton truss pletes identified by e hexogon stomped every 1-1/4" along the center of the plate. RAFTER LENGTH 15'8-1/8" Webs ere 2x4's except where noted 2"x4" NAILERS -- `3-2"x6" LAMINATED COLUMN T#21 CORNER TRiM 2"x4" (NO, 1SYP) HORIZONTAL BLOCKS @ 16" O,C, CONSTRUCTED AS A LADDER FRAME FOR EASE OF INSTALLATION (2) LAYERS 5/4" O,S,B.* O.S.B. SHEARWALL DETAIL SCALE: 11/2'= 1'-0" ~' - O.S.B, FASTENING INSTRUCTIONS: 1,) FASTEN FIRST LAYER ,3/4" O,S,B, W/Ed NAILS @ .3" O.C. ALONG PANEL EDGES AND 6" ALONG INTERMEDIATE FRAMING. 2,) FASTEN SECOND LAYER .3/.4" O,S,B. W/lEd NAILS @ .3" O.C. ALONG PANEL EDGES AND 6" O,C, ALONG INTERMEDIATE FRAMING, 5-2"x6" E.C,E END 2"xS" (NO. 1SYP) BACKER BLOCKS AT BOTTOM OF END TRUSS WITH 1Od R,S, GUN NAILS @ 5" (SEE BACKER BLOCK DETAIL) IIII _/ 2"x4" (NO, I SYP) HORIZONTAL BLOCKS @ 16" O.C. CONSTRUCTED AS A LADDER FRAME FOR EASE OF INSTALLATION 2"x4" SIDEWALL (2) LAYERS 3/4" (~(~)FIRST AND SECOND LAYER JOINTS SHALL BE STAGGERED .3-2"x6" LAMINATED O.S.B. II I ~-2"x8" TREATED SPLASHBOARD SHEARWALL FRAMING ELEVATION 11x15 PI. CAMBER AT CENTERLINE 3/4" #2 16x9 PI. 18 Ga, ~/16" 6x9 PI, #4 PI. 9x9 PL 2"x8" L.C, 1~'10-1/2" TRUSS SPACING 7'-6" O,C. LIVE LOAD 56 PSF DEAD LOAD 4 PSF CEILING LOAD ,PSF TOTAL LOAD 40 PSF YES #5 12 94 2-16x8 Pi, 18  PI. 18 Ga, 15 1/2" CCP 30' S.C. TRUSS 2"x4" PURLIN END TRUSS GUN INAILS @ .3" O,C. (NO. 1 SYP) BACKER O,S.B. FASTENING * (2) LAYERS 3/4" O,S.B, SACKER BLOCK DETAIL 60d R,S. NAIL BLOCK TRUSS · GALV. PURLIN CONNECT(~ " - SCREW ON PEAK SIDE AND (2) ON EAVE SIDE OF PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) BUTTED PURLIN DETAIL 2"x4" PURLIN 60d R.S. NAIL (~)(~)USP RT4 HURRICANE ANCHOR FASTEN TO TRUSS AND PURLIN~ W/ (4) 8d x 1 1/2" NAILS (1 ~/2" R,S,) TRUSS 20 ga, GALV, " - SCREW ON PEAK SIDE AND (2) ON EAVE SIDE OF PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT BEFORE FASTENING CUPS) PURLIN CONNECTOR 2"x4" BUTTED PURLIN DETAIL 128-0733 t"'DRAWN BY: JK 823 DATE: 6/10/04 CHECKED BY: DATE: REVISED DATE: REVISED DATE; i REVISED DATE: ~REVISED DATE: · I SCALE: AS NOTED SHEET NO. S5 OF S5