Loading...
HomeMy WebLinkAbout35514-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-34872 Date: 03/17/11 T~IS u~KTIFIES that the building UNHEATED ACCY GARAGE Location of Property: 12600 NEW SUFFOLK AVE (HOUSE NO.) County Tax Map No. 473889 Section 116 subdivision CUTCHOGUE (STREET) (HAMLET) Block 6 Lot 13 Filed Map NO. Lot NO. conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 23, 2010 purs%~nt to which Building Permit No. 35514-Z dated APRIL 27, 2010 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is UNHEATED NONHABITABLE ACCESSORY TWO CAR GARAGE WITH ATTACHED SCREENED PORCH (RELOCATED AND RENOVATED) AS APPLIED FOR. The certificate is issued to LEONARD & AMY P WESSELL III ( OWNER ) of the aforesaid building. SuFFOLK COUN~"fDEPART~TOFHEALTHAPPROVAL N/A ELR~-£KICAL t~RTIFICJ%~ NO. 33514 11/15/10 PL~]~BERS CERTIFICATION DA'£~u N/A ri z~ Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35514 Z Date APRIL 27, 2010 Permission is hereby granted to: L & A WESSELL 12600 NEW SUFFOLK AVE CUTCHOGUE,NY 11935 for : RELOCATION & RENOVATION OF AN ACCESSORY UNHEATED 2 CAR GARAGE WITH ATTACHED SCREENED PORCH AS APPLIED FOR at premises located at County Tax Map No. 473889 Section 116 pursuant to application dated APRIL Building Inspector to expire on OCTOBER 12600 NEW SUFFOLK AVE CUTCHOGUE Block 0006 Lot No. 013 23, 2010 and approved by the 27, 2011. Fee $ 409.60 AuthoriZed Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 76S-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board o f Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from amhitect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Old or Pre-existing Building: c/ Locationoferoperty: I ~,00 Af~ ~.~.~LIro(~_ ~ House No. Street Owner or Owners of Property: ~ r~t::t ,~J EL/~ ~-rrl ~ Suffolk County Tax Map No 1000, Section \ ~ ~ Block (check one) s ell, Iff Lot Hamlet Subdivision Permit No. '~_'~ ~ I ~l Health Dept. Approval: Planning Board Approval: Date of Permit. Filed Map. Applicant: Underwriters Approval: Lot: Request for: Temporary Certificate Fee Submitted: $ ~ 0 ,~ 0 Final Certificate: (check one) Applicant Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 roRer, dchert~..town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Amy Wessell Address: 12600 New Suffolk Ave City: Cutchogue St: NY Zip: 11935 Building Permit #: 35514 Section: 1 1 6 Block: 6 Lot: 13 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Rocky Point Electdc Inc License No: 32644-me SITE DETAILS \ Office Use Only Residential ~ Indoor ~ Basement ~ ServiceOnly ~ Commerical Ou~loor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Affic Garage INVENTORY Servicelph ~ Heat U DuplecRecpt ~ Service 3 ph Hot Water GFCl Respt Main Panel .~JC Condenser Single Recpt Sub Panel A/C Blower Range Rec, pt Transformer Appliances Dryer Reqet Disconnect Switches Twist Lock Other Equipment: 2 story detached garage Ceiling Fixtures [~ HID Fixtures Wall Fixtures ~.~ Smoke Detectors Recessed Fixtures ~.~ CO Detectors Fluorescent Fixture ~ Pumps Emergency Fixturesl.~ Time Clocks Exit Fixtures ~ 'rvss Notes: Inspector Signature: ~ Date: July22 2011 81-Cert Electrical Compliance Form Town ! Ldl Anne× 5 ~375 Mare Road P.(). Box 1179 South(fid, NY 11!)71-095!) Tclcpl tottt? ((i31 ) 765-1802 Fax (631) 765-9502 ro.qer.richert~town.southold.ny, us B! 'ILl)IN(; I)EI'AI{TMENT TOWN OF $OUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Wessell ~ddress: 12600 New Suffolk Ave City: Cutchogue St: NY Zip: 11935 ~uilding Permit #: 33514 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE 3ontractor: DBA: Rocky Point Electric License No: 32644-me SITE DETAILS Residential Commerical New Addition Service 1 ph Service 3 ph Main Panel Sub Panel Transformer Disconnect Other Equipment: Office Use Only Indoor ~ Basement ~ Service Only ~ Outdoor 1st Floor Pool Renovation 2nd Floor Hot Tub Survey Attic Garage INVENTORY Hot Water GFCI Recpt Wall Fixtures NC Condenser Single Recpt Recessed Fixtures NC Blower Range Recpt Fluorescent Fixture Appliances Dryer Recpt Emergency Fixtures Switches Twist Lock Exit Fixtures HID Fixtures Smoke Detectors CO Detectors Pumps Time Clocks TVSS Notes: de~ched garage Inspector Signature: Date: Nov 15 2010 81-Cert Electdcel Compliance Form TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ~FOUNDATION 1ST [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL ] FIRE SAFETY INSPECTION ] RRE RESISTANT PENETRATION [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ REMARKS: DATE INSPECTOR'S. ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]ROUGH PLBG. [ ]~NDAT~ [ ]INSULATION [,~ FRAMING~ ST~_~ [ ]FINAL [ ] FIREPLAC~&-C~IMNEY [ ] FIRE SA~ IN~ON [ ] RRE ~ ~~ [ ] RRE R~ ~~ REMARKS: ~/'~ ~ ~~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. ]~ION 2ND [ ] INSULATION [~'~FRAMING~ STRAPPING [ ] FINAL FIREPLACE & CHIMNEY [ ] fiRE SAFETY IIL~ECTION [ ]I:II~I~SlSl'ANTCONS11~l~ []RI~R~Sl'ANTI~IEll~IlON REMARKS: ?~-'~ ~D~::~ DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION  FIRE RES~A#I' CO#STR~ [ ] FIRE RESA'TANT PENETRAtiON ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: INSPECTOR~'~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] ROUGH PLBG. ]FOUNDATION 2ND [ ] IN~I~TION ] FRAMING / STRAPPING [ ~ FINAL ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION 1 F1.E .F..ST~~ II F~.E .E.m.T mmJT~0. REMARKS:~~,~--r~_A - DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROU~/~PLBG. [ ] FOUNDATION 2ND [ ]~J~ [ ] FRAMING / STRAPPING [ i/]"FIN~ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAr.', T' INSPECTION [ ] FIRE RESISTANT COflSTRUCTIOfl [ ] ,FIRE RESISTANT PENETRATION REMARKS:..~ ~~~_~ ~ / DATE --~ INSPECTOR .~ OWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] RRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ~ELECTRICAL (FINAL) REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST FOUNDATION 2ND FRAMING / STRAPPING FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ~LECTRICAL (FINAL) REMARKS: DATE __ FLELD Ih ~t'~r~'l'~0N REPORT DATE COMMENTS FO~A~ON (1S~ · ROUGH ~G ~ ' ' PL~G STA~ EN~ CODE ~D~ION~ COUNTS TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined Approved Disapproved a/c ~z/~.? ,20/0 ..7///~7,20/Z~ Expiration /0///~x 7' 20/,,/ PERMIT NO. ~ ~5-J ¢/ ! Building Inspector BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: APR 2 3 2010 BLDG. DEPT. TOWN OF SOUTFIOLO APPLICATION FOR BUILDING PERMIT Date ., 20 INSTRUCTIONS filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) iBAYEP-_ Cb ' (Mailing ad~lres~ of applicant) - State whether applicant is owner, lessee, agent, architect, engineer, etg'~neral contraxtor)electrician, plumber or builder Nameofownerofpremises ]---Lm'~O/0Aff---~ ~ A~-4y [/OI~SS~L,t_,- (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License 1. Location of land,on which proposed work will be done: House Number Street ~ Hamlet County Tax Map No. 1000 Section } I ¢ Block ~ ~o Lot 13 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost :~ ~0~ 0-0~) Fee 5. If dwelling, number of dwelling units If garage, number of cars c~ Addition Alteration ~ Other Work (~60c,qrt~ · t~o~ oo, ad-.e_ E-~is~i tO t; I~o;c~;,)(a (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Height Number of Stories Dimensions of same structure with alterations or additions: Front Depth ,~q' Height o').~0 ' Dimensions of entire new construction: Front Height Number of Stories 9. Size of lot: Front 10. Date of Purchase 2-- 0 (~ Rear Name of Former Owner _Depth ~;5 ~ -' Rear ,~5.!. ~ Number of St~ii4s al, ,.. ~ '" Depth '' ~ Rear i ~ ..... it Depth 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO ~ 13. Will lot be re-graded? YES NO ~ Will excess fill be removed from premises? YES '~ NO · Address 2,205' 14. Names of Owner of premises Le~}e~)~55e£c ~Baul~cae~.~ Phone No. 30 ~. , Name of Architect .~'o~'~ ~'oT~C& Address p~ IWo~l (3ooaue~ ~ Phone No NameofContractor~d¢oa'd,(,,.--~Pco,l~C Address2"[ql3~¥~-~ ',~' PhoneNo. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES '/ NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES ~/ NO __ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES · IF YES, PROVIDE A COPY. NO t/ STATE OF NEW YORK) SS: COUNTY O F~t/Jc4 ~ b bO.4 F--f3 ~/fi I-UD being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this w, . Nota~, Public ........ uS. 30-4741154 Signature of Apphcant · 2 UUallTleO in massau / Suff~ Commission Expires /~ Telephone (631) 76~180~ nb'II/)INO DEPAIITM~T TOWN OF APPL TI I p f *Name: *Address: *Cross Street: *Phone No.: Permit No.: Tax Map District: REQUESTED BY: ~ompany Name: .... ~' Date: Name: c, ' ~ne No.: I 0 '- I~ ~ JOBSITE INFORMATION: (*lndi~tes r~uimd Info~ation) . /,;, , 1000 Section: Block: ' Lot: *BRIEF DESCRIPTION OF WORK (Please Print Clearly) Please Clmle All That Apply) ~ 'Is Job ready for Inspection: Do you need a Temp Certificate: 'amp'Information (If needed} YES / NO Rough In YES I NO ~., ..- / Final Service S/ze: 1 Phase 3Phase 100 150 200 300 350 400 Other ~o~: .,Re-connect Underground Number of Meters Change of Se~0e Overh,d e~ fnmrmatfon: PAYMENT DUE ........ - WlIH APPLICATION e2-Re~uest f~r Ins~t~n Form Ti}xxn Hall Annex .5 [375 Main R{~ad 1'.(). Box 1179 Si)uth~ fid, NY 11971-09,59 Telephone (631) 765-1802 Fax ((3231) 76.3-9.502 I~,[!II~I)IN(; I)H'AI/TMI~NT TOWN OF $OUTHOLD November 5, 2010 Leonard & Amy Wessell, III 2205 Topaz Ddve Boulder, CO 80304-0926 RE: 12600 New Suffolk Ave, Cutchogue TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occuancy: "~ Application of Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. ~ A fee of $50.00 __ Final Health Department approval. __ Plumbers Solder Certificate. (All permits involving plumbing after 411184) __ Trustees Certificate of Compliance. (Town Trustees #765-1892) __ Final Planning Board approval. __ Final Fire Inspection from Fire Marshal. __ Final Inspection from the Building Dept. __ Final Landmark Preservation approval. Building Permit: 35514-Z accy garage LOT COVERAGE DEC JURISDICT. (51,488 DESCRIPTION EXIST. HOUSE PROP. PORDHS PROP ADDITIONS PROP. 2 STORY ADDITION CONNECTOR ADDITION PROP. DECK PROP SHEDS PROP POOL PROP, POOL TERRACE TOTAL EXIST. & PROP. TOTAL LOT (81,448 sq. TA ON AREA DpW£LLIN (USEs WITHIN DA TA LOT COVERAGI 2.1% 0.6% 2.5% 2.0% 1,2% sq. ft 2.0% sq. ft. 14.0% SURVEY OF PROPERTY < / SmUArZ o / CUTCHOGUE / TOWN OF SOUTHOLD > / SUFFOLK COUNTY, NEW YORK / S.C. TAX No. 1OOO-116-O6-13 /- ',AC'ANt SCALE 1"=30' ~ APRIL 4, 2006 ·., . , ~. , b'hNh~. ~ · SEPsIEEpMIBEEMRBE1Rl'223?O280018DD~EI%K(EARpRoR:OOSFE;OADBDEITIROE~SU`LT ~rttzs,~ __ 9- · · ~ A V ~j2~/FUS ~~ FEBRUARY', 2010 REVISED PROPOSED ADDITIONS NOTES 1. ELEVATIONS ARE REFERENCED TO 1929 N.G.V.D. DATUM /~e PROPOSED EXPANSION POOL t(////~ PROPOSED SEPTIC TANK ELD/ 1,% 14' PROPOSED SEPTIC SYSTEM DETAIL (NOT TO SCALE) POOL OF A 3 POOL SYSTE~ NYSDEC APPROVED AS PER TERMS AND CONDITIONS OF PERMITTNO,/~49~1 ]oooO[ ~ OJh DATE ~_~JaeJig ~ l' ' UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY I% A VIOLATION OF SECIION 72fl9 OF THE NEW YORK STATE EDUCATION L~W THE EXISTENCE OF RIGHTS OF WAY NYS Lm No 50467 Nathan Taft Corw n III Land Surveyor PHONE (631)727-2090 OFFICES LOCATED AT Fox (631)727 1727 LOT COVERAGE DAT~ DEC JURISDICTIOI (51,488 sq. TOTAL LOT COVERA, (81,448 sq. APR 2 3 2010 SURVEY PROPERTY CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-116-06-13 SCALE 1"=30' APRIL 4, 2006 JANUARY 23, 2008 S~ ~TH FOR S~TE INSPECTION FEBRU~Y 26, 2008 ADD SEPTIC SYSTEM CROSS SECTION SEPTEMBER 11, 2008 ADDED GAR, ROOF TO BE REBUILT ,00 AUGUST 19, 2009 ADDED PROPOSED GAUGE OCTOBER 20, 2009 ~'SED PROPOSED ADDmONS DECEMBER 15, 2009 STAKE PROPOSED GARAGE 2, 2010 STAKE PROPOSED GARAGE APRIL 22, 2010 ADDED NEW FLOOD ZONE ~ AREA = 81,448 sq. ft. (TO TIE LINE) 1,870 ac. '\ \ h \ h 1. ELEVATIONS ARE REFERENCED TO 1988 N.A.V.D. DATUM · -- EXISTING ELEVATIONS ARE SHOWN THUS: ~ DO EXISTING CONTOUR LINES ARE SHOWN THUS: .... 10 ~' PROPOSED CONTOUR LINES ARE SHOWN THUS: ~ ~3 2. THE LOCATION OF WELLS AND CESSPOOLS SHOWN HEREON ARE FROM FIELD ~' OBSERVATIONS AND/OR DATA OBTAINED FROM OTHERS. 5, ANY WETLAND BOUNDARIES SHOWN ARE SUBJECT TO VERIFICATION BY NEW YORK STATE AND/OR OTHER REGULATORY AGENCIES. 4. FLOOD ZONE INFORMATION TAKEN FROM; FLOOD INSURANCE RATE MAP No. S6103C0501H ZONE AE: BASE ~-LOOD ELEVATIONS DETERMINED ZONE X' AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. ZONE X*: AREAS OF 0.2% ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE FLOOD WITH AVERAGE DEPTH OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE, AND AREAS PROTECTED BY LEVEES FROM IO0-YEAR FLOOD, 5, MINIMUM SEPTIC TANK CAPACITIES FOR 4 BEDROOM HOUSE IS 1.000 GALLONS. 1 TANK; S' LONG, 4'-3" WIDE, 6'-7" DEEP 6.MINIMUM LEACHING SYSTEM FOR 4 BEDROOM HOUSE IS 300 sq ff SIDEWALL AREA. 5 POOLS; 4' DEEP, 8' die. PROPOSED EXPANSION POOL PROPOSED LEACHING POOL PROPOSED SEPTIC TANK 7.EXISTING SEPTIC SYSTEM STRUCTURES SHALL BE PUMPED CLEAN AND REMOVED IN ACCORDANCE WITH S.C.D.H.S. STANDARDS. APPROXIMATELY 200 cu yds. OF CLEAN FILL SHALL BE TRUCKED IN FROM AN UPLAND SOURCE FOR THE PROPOSED FILL AREA AROUND THE PROPOSED POOL AREA. TEST HOLE DATA 03' 14' 0 0 PROPOSED SEPTIC SYSTEM DETAIL LEACHING POOL OF A 5 POOL SYSTEM SEPTIC TANK (1~ qo. 50467 Nathan Taft Corw n III Land Surveyor SURVEY OF PROPERTY S£TUA TE CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-116-06-1.5 SCALE 1"=30' APRIL 4, 2006 SEPTEMBER 11, 2008 ADDED GAR. ROOF TO BE REBUILT SEPTEMBER 23, 2008 STAKE PROPOSED ADDITIONS AUGUST 19, 2009 ADDED PROPOSED GARAGE =EMBER ,B DOB9 STAKE PBOPOSEB OABAGE DEC~E~MBER 4 20 0 FNAL SURVEY AREA 81,448 sq. f1, (TO TIE LINE) 1.870 I I I I I I I NOTES: 1. ELEVATIONS ARE REFERENCED TO 1988 N.A.V.D. DATUM EXISTING ELEVATIONS ARE SHOWN THUS: J~ EXISTING CONTOUR LINES ARE SHOWN THUS: .... 10 .... 2. FLOOD ZONE INFORMATION TAKEN FROM: FLOOD INSURANCE RATE MAP No, S610~C0501H ZONE AE. BASE FLOOD ELEVATIONS DETERMINED ZONE X. AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN, ZONE X*~ AREAS OF 0.2~. ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE FLOOD WITH AVERAGE DEPTH OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM ~O0-YEAR FLOOD. SEPTIC SYSTEM TIE MEASUREMENTS HOUSE HOUSE CORNER ~ CORNER[~ SEPTIC TANK COVER 1 16.3' 25' SEPTIC TANK COVER 2 22.S' BO.5 LEACHING POOL COVER 1 $9.7' 50.4' LEACHING POOL COVER 2 48,9' 56.5' LEACHING POOL COVER 3 35,9' 41.5' Zo,v~--; THE EXISTENCE OF RIGHTS OF WAY AND/OH EASEBENTS OF RECORD, JF ANY, NOT SHOWN ARE NOT GUARANTEED* N.Y.S, L,c No 50467 Nathan Taft Corwln III Land Surveyor PHONE (651)727-2090 Fax (651)727-1727 36-075 J WINE ForFi A.P.A. [ SHEA' J III -BORNE DEBRIS PROTECTION FASTENING DR W,QOD STRUCTqRAL PANELS. /lax. 33 -0" MEAN ROOFiHGT. HOUSES PAN RATED 48124 GRADE 15132 STRUCTURAL HING -OVERLAP OPENING ~VIIN. 4" TO ALLOW FOR FASTENER CONNE~;TION AND 2X4 LIBSTRATE WHERE REQ'D.I ALL METAL PARTS TO BE GALV. OR STAINLI~SS STEEL. ALL )ANELS, SUBSTRUCTURES', AND FASTENERS TO BE HUNG UNDER ']'HE HOUSE. DEPT. :5OUTDOLD S U E R AND S U T E R DESIGN * ARCHITECTURE PO BOX 170~ L' A IN D S C A P E 124 JES SUP AVENUE QUOGUE, NY I 1959 www fiulelandsuter corn F A X 63 I 653 387 fi - I ',1 Figure 3.8a Corner Stud Holddown Detail - 3 Studs With Blocking Sidewall~ nails at :L0" o.c. 4 4:----- L OCCUPANCY OR ~ ...5 IS IJNLAWFUL ""::!":::""'. (",ERTIFICATE 4 -,,, ,~, .IiEETTHE , ~FqOFNEW :,BLE FOR .IhL:C;L,N ERRORS, OF ALL CONSTRUCTION SHALL MEFr TFZ REQUIREMENT8 OF THE COD~S OF NEW YORK STATE RETAIN STORM WATER RUNOFF ?URSUANT T0 CHAPTER 236 OF THE TOWN CODE. P.O. BOX 63 I 653 CONNECTIONS AROUND ~JUALL OPENINGS WFCm ~', z.3.?, 3,2 5 4 709 124 JESSUP AVENUE [87? QUOGUE, Nh' 11059 £ "&'; LL -- ///LL.I 1) ALL FOOTINGE 2) ALL CONSTRU* CHANGES. ALL CONCRETI 5} BRIDGING MA.X 6) DOUBLE ~LOOI TO REST ON VIRGIN SOIL & BE A MIN. 3'-0" BELOW FINISHED GRADE. ;llON TO CONFORM TO ALL STATE & TOWN BUILDING CODES INCLUDING 200~ TO SE MIN. 3,0OD P.B.I. 28 DAY STRENGTH. - ~a~ ~ ~-/~ .~- ~..~,~.~r~l o £. UMBER TO BE DOUG. FIR ~2 UNLESS NOTED OTHERWISE. 8'-0" ON CENTER. ~ JOISTS UNDER PARALLEL PARTITIONS AND BATHROOMS. ;~DS UNDER HEADER OF ALL SPANS OVER 4'-0'. MIN. HDR SIZE (2) 2)(10 UNLESS AILS TO BE GALVANIZED NEAR SALT WATER EXPOSURE. ; OVERRIDE DIMENSIONS. DIMENSIONS OVERRIDE SCALING. IRDERS TO BE GLUED & NAILED· ALL LUMBER TO BE CONTINUOUS LENGTHS. JTCH BEAMS TO HAVE %" DIA. BOLTS 16' ON CENTER ON Bo~rOM & 24' ON CENTER , BE 2' FROM EDGE· MIN~ 3'X3"Xl/4" STEEL BEARING PLATE AT EACH END. F FURNACE AND AITACHED GARAGES TO BE FINISHED WITH 518' FIRE PROOF G·W.B. 3E SUPPLIED WITH FRESH AIR VENT AND GLASS DOORS PER 2C03 ENERGY' I CODES AND FIRE PROOF HEARTH TO BE INSTALLED PER CODE. (FRAME FLOOR 3E AT HEARTH WITH REQUIRED SETBACK). FIREPLACE FOOTING TO BE 12" THICK BEYOND FIREPLACE POUR. WELDED WIRE MESH 2" FROM BOl'rOM TO BE IN THE q 4"X8'X16" CONCR~ ~ E BLOCK 3'-0' ' ' · ALL DECK FRAMING TO BE .4 C.C.A. PRESSURE TREATED LUMBER· LALLY COLUMN TO BE FILLED WFTH POURED CONCRE ~ ~. C3NCRETEPIERS ON 16"X24"X12' POURED CONCRETE ~ TO BE 4' POURED CONCH~ ~. ONCRETE WITH 6'X6'X6/6 STEEL MESH REINFORCING ON PITCH SLAB TO DOOR MIN. % ~ PER 1 '0' IR VENT AND FIRE PROOF FLOOR TO CODE. iN ALL'LOAD BEARING WALLS· CODE. MAX. 8'-0' ON CENTER WITH I HOUR RATING USE 5/8" ~ BOARD; GARAGE TO CODE 45 MIN. RATED WALL, DOOR, & JAMB· DOOR TO G. =COL IS INCLUDED IN THE PROJECT, IT MUST SE ENCLOSED WITH A 4' HIGH FENCE & GATES, TO NYS CODE· ER TO BE INSTALLED AFTER MOISTURE CONTENT F~EACHES AMBIENT EQUILIBRIUM GIRDERS, FL. JOIST, TRIM, ETC. ~F'TER TIE DOWNS TO TOPPLATES IN ALL FULL HGT. CLGS (CATHEDRAL) & ALL kSHORE. (SEE HIGH WIND NOTES) OR ]~EK OR LQ,) TO COMPLETELY COVER SHEATHING. ~S, MICROLAMS OR EQUAL ARE UBED~ FOLLOW ALL MANUF. SPECS. FOR SITE &LATION, DR;! LING, BLOCKING, & LOADING. IS NOT RESPONSIBLE FOR CONSTRUCTION ME.~NS OR METHODS· tb CHANGE3 IN rRF PLANS MUST SE APPROVED BY TI~E ARCHITECT OR THE )T RESPONSIBLE FOR THE ENTIRE PROJECT. ASSUMES NO SITE CONDITIONS THAT ARE NOT INCLUDED IN TRE PLANS. ANY ROCK [bROCK, UNDERGROUND STREAMS, ETC. MUST BE SITE INSPECTED BY A LOCAL ' STRUCTURAL CHANGES THAT OCCUR THAT CHANGE THE PLANS ARE NOT THE OF THE ARCH(TLC r. [RCHITECTURAL WORKS COPYRIGHT PROTEC'rlON ACT PER UNITED STATES CODE ~RAL WOFd( CREATED A~ I ER DECEMBER 1, 1990. INCLU DING THIS SET OF PLANS, iN ALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPEC~ AND E DESIGN, FOR A PERIOD O~ 75 YEARS I RESIDENT[AL CODE OF NEW YORK STATE DATED JAN. t, 2007 / / I - heaw moderato ' T -L~- ',RTE COMPRESSIVE STRENGTH [ SEVERE GARAGE SLAB 3,500 PSI CONC ..... FJ,~EI B~T~(.v'A_[;L~_&_S~SS - 3~0Q0 PSI Table 3.1 Nailing $chedMle 8d 24d i0d (see Tablc 3 11) 3"ed~c/d'' field N! IK STATE RESIDENTIAL CODE ·-iSUTER A.ND_ ;UTER· PO BOx 1709. QIIOGUE, NY-119591.,1631).653.3877 TYPICAL WALL SECTION VENT TOP OF ROOF W/RIDGE VENT 0R R00F VENTS T0 CODE ~" COX EATT INSULATION WNAPOR BARR[ER ON · HEATED S{qE. % GYP. Bb. FASCIA SO FFIT WICONT. VENTING ~INISHED FLOOR - ~" CDX BUEFLOOR GLUED AND SCREWED CtEAN SAND BACKFILL Table 3.2A 5/8" Anchor Bolts - ~iil Plato to Foundation Connections Resisting Shear Loads from Wi~nd - Exposure B (Prescriptive Alternative to Table 3 2) Table3.2C Sill or Bottom Plate to Foundation Connections (Anchor Bolt Resisting Uplift Loads from Wind - Exposure B COMPLIANCE W/2007 C0-D~, BY-U-SI~TG~A~F~M. WOOD FRAME CONSTRUCTION MANUAL~OOI EDITION USING PRESCRIPTIVE DESIGN METHOD· ~" DIAMETER "J" BOLT PER TABLE 3.2A & 3.2B CENTER SPACING INTO FOUNDATION WiTH 4" x 4" x N ~ B.P. FLATE OVER SILL PLATE. ~.~,E,~I~ ~"srX,_F0_ GAGE STRAPS @ EA.C,~H JOINT, SILL PLATE TO FIRST FLOOR WALL uuu, 1 I-LeeR WALL STUDS TO 2''~ FLOOR WALL STUDS, WALL STUDS AND TOP PLATE TO ROOF RAFTERS AND OVER RIDGE AT EACH RAFTER OR 2X4 CO' LAR TIE IN UPPER THIRD OF A~'IC AT 16" ON CENTER. - ASPHALT SHINGLES FOLLOW NAILING SCHEDULE R905,2.6 MIN 6 FASTENERS PER SHINGLE, BLDG. FELT, fflSTALL PER R905.2.7 .(ICE SHIELD REQUIRED FOR 1s~ 24" ABOVE Gl'ART OF INTERIOR WALL) N.Y.S. BLDG ,CODE- TABLE R301.2 (20_WINDOWS TO MEET D.P. RATING OF MIN. 40 Table 3,2 TABLE R301.5 MiN{~6 U M urEFORMLY DISTRIBUTED LIVE LOADS (In pound~ per square 40 - 200 50 Table 3.6A Sill or Bottom Plate to Foundation Connection Requirements fog- Wind - Exposure B Table 3.2B Bottom Plate to Foundation Connections (Anchor Bolts) Resisting Lateral and Shea~ Loads from Wind - Exposure B , ,~ Table 3,9A (Roof-to=Wail~ Wall-to-Wall, and Wall=to-Foundation} Table 3.4A Rafter/Ceiling Joist Heel Joint Connection Requireraents (Prescriptive Arternahve to TabLe 3 9) Rafter and/or Ceiling Joist to Top Plate Lateral and 6hear Connectionl Requirements - Exposure B (PrescrrpLive AlternaUve to Table 3.4) CHAPTER 6(~0 HOUSE RATIO LESS THAN 4:1 STRUCTURAL SHEATHING TO SE FULL HGT. SECURE TO TOPPLATE. ROOF PITCH ~ S'5-o ~: MAX 42% GLASS OK