Loading...
HomeMy WebLinkAbout35916-ZFORM NO. 4 TOWN OF SOUTBOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-34818 Date: 01/25/11 T~IS CERTIFIES that the building WINDOW REPLACEMENT Location of Property: 4522 GREAT PECONIC BAY BLVD LAUREL (HOUSE NO.) (STREET) County Ta~mp No. 473889 Section 128 Block 4 Lot 19 Sul~ivision Filed ~4ap No. Lot No. (HAMLET) conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 22, 2010 pursuant to which Building Pez~ait No. 35916-Z dated OCTOBER 4, 2010 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is WINDOW REPLACEMENT IN ~2~ EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to FAIR WINDS LLC of the aforesaid building. ( OWNER ) SuFfOLK COUN~"f DEPART~E~T OF }~%LT~ APPROV~J~ ~.Rt-£KIC~J~ U~'rIFIC~%I~ NO. PL~E~ CERTIFICATION DA'£~D N/A N/A N/A //uth~ z ed ~ignature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35916 Z Date OCTOBER 4, 2010 Permission is hereby granted to: WINDS LLC FAIR 225 MOUNTAIN AVE RIDGEWOOD,NJ 07450 for : WINDOW REPLACEMENT TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 4522 GREAT PECONIC BAY BLVD LAUREL County Tax Map No. 473889 Section 128 Block 0004 Lot No. 019 pursuant to application dated SEPTEMBER 22, 2010 and approved by the Building Inspector to e~ire on APRIL 4, 2012. Fee $ 200.00 Authorized Signature ORIGINAL 518102 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey °f property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept of water supply and sewerage-disposal (S_9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit PI.arming Board Approval of completed site plan requirements. B. Fo~ existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: I. Accffcate survey 0f pr0perty showing all property lines, streets, building and unusual natural or topographic features. · 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelliug $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 · 4. Updated Certificate of Occupancy - $50.00 · 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. Old or Pre. existing Building: New Construction: Location of Property: House No. Owner or Owners 0f Property: .. Suffo~ Co~W T~Map No 1000, ~tion / Subregion Health Dept. Approval: (check one) Street Date o f permit. O CJ ~//~ o l O 'Planning Board Approval: Hamlet -Block ¢ Lot / ~' Filed Map. Lot: Underwriters Approval: Request for: Temporary Certificate Fee Submitted: $ Final Certificate: ~X~ (check one) ~ppli~ant Sig~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSUlaTION [ ] FRAMING / STRAPPING [/.d~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SA,-,- i ~' INSPECTION [ ] RREREs~rJxr~ [ ] F~RERESm'Am'~F.,ETRA'n0, REMARKS: (~o~r-~ ~ DATE ~ INSPECTOR FOUNDATION (IST) FOUNDATION ¢~) STA~ E~R~ CODE ~D~ION~ ~ m TOWN OF SOISTHOLD · BUILDING DEPAl~TMl~NT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork. net PERMIT NO. Examined 20 __ ^.roved ! Expirafio~~ BLDG. DEPI. TOwNOFSOUTHOtD BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health ~ll 4 sets of Building Plans~ Planning Board approval Survey Check Septic Form N.Y.S.O.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: ~ ~. P-~- ~ ~ Mailto: 3~-~'~ ~ ~~, Phone: J~3l ~ ~_~j- Building Inspector >LICATION FOR BUILDING PERMIT INSTRUCTIONS Oate__~_ ,~V,e~ Z o , 20~O a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (S~gnature of applicant or name, ifa eorporatibn) CO r ~>. (Mailing address of applicant) I ~o1,~ ~ State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~-[l~ltO ~M ?~"~ ~ ~' ¥~ I,~ ~ (As on the tax roll or latest deed) If apl~cant is a corpor~io~ signature of duly authorized officer .ne and ftle of corporate officer) Builders~License No. 2d4~/40 - /'/ Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section [)..~3 Block__ q Lot Ct Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~ ~,~ ~.~. x~'tXx~t ,x~! b. Intended use and occupancy ~ ~ ,~oq t~ ~"~,¢~.~,q ~ ~>,,~,,3 ¢~ ! 3. Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars t Addition Alteration Other Work Wi (DescriI~tion) Fee OCD. (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Hei§h~[ Number of Stories Rear _Depth Dimensions of same structure with alterations or additions: Front Depth Height_ Number of Stories Rear 8. Dimensions of entire new construction: Front Height Number of Stories Rear Depth 9. Size of lot:Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO '~ 13. Will lot be re-graded? YES NO ~N Will excess fill be removed from premises? YES __ NO 14. Names of Owner of premises Name of Architect Name of Contractor Address Phone No. Address Phone No Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES .~ NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. ls this property within 300 feet of a tidal wetland? * YES ,~ NO__ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ · IF YES, PROVIDE A COPY. NO STATE OF NEW YORK) SS: COUNTY O~ ~_~-~ ~ bt IA/'htl~:~Xc~t~/ being duly sworn, deposes and says that (s)he is the applicant (Name of indMdual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swom to before me thi~ ~t9¢pt- day 0~f~X~,~9~tgt'/~_ 20/0 N~ 016A61~911 ~ Si~tnature °f Applica,nt Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSM,:NT FORU PROPERTY LOCATION: $.C.TJM. ~ THE FOLLOWING ACTIONS MAy REQUIRE THE SU~at~e~O-_ OF A SCOPE OF WORK - PROPOSED CONSTRLTUI'ION Ii'EM# / WORKASSESSM~NT I Yes No Ihe Scope of Work for Proposed Cons~-'Uon) Generated by a Two (2") Inch Rainfall on Site? constm~on activity? ~) ~.~ ~-. Site Improveme~te and the permanent creation of imperious surfaces.) t~"'~ ('~d~'~ ~)~,&~ '~::~CL Ix~,"~. Item must be maintained thro.Jghout the Entim "~_~u-,~Act-- ~-~s~%~-,~,~'t; 4 Wl#thJsProjectRequireanyLarld~lliflg, Gradingor ~/~. ~,~,,, ,~, ~. ,~_~j,.~ ~ Excavation where them is, change to the Natural ~1~ U ~"~' ,'~ ~,;~,* ~ ~ ~O ~.'~ of Material within any Parcel? ~ 5 W~II Iflis Application Require Land Olstuffoing Activities [ (5.000 S.F.) Square Feet of Ground Surfaco? Site? Is this Project within the Trustees judsdlc~on ~e DEC has determined that e SPDE$ p~mlt is requlm~ for storm v~ter ~scharges. One Hundred (100') of Hodzonter Dista~ce? ~ co~'y oF ....~..F~_~L..~ ................ ss That I, And that he/she is the ....... .~...~.-~.~.1~,... o~. c~n~. ~i~"~'~'~gi ................................................ Owner artd/or representative of the Owner or Owners, alld is duly authorized to l:~,.rform or have performed the said wolk a.qd to make m}d file this application; that all statemen~x coutaJned kl this applicafiolt are ia'ue to ~e best of his lulowledge aild belief; and that the work will be performed in the maraxe~ act forth it~ the application filed hereu,ldl. Sworn to before mc thia; ..................... ......... ................................ ............ FORM - 06/10 Iio. 01GA6123911 i~ltfled la Sdfolk ComflY ~o Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall Annex 54375 Ma~n Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 September 15, 2010 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Mr John Catera H~'r~ptons Habitat 381-13 Old Riverhead Rd ~0 Westhampton Beach, NY 11978 Dear Mr. Catera: The Bo~rd of Trustees reviewed your request dated September 7, 20.,1.0-~z~determined the installation of new or replacement windows, roof shingles, doors~,~orr~er.~ and siding on existing strUctures does not require a permit in accordance with Ch~1~-'275-4 Exceptions of the Town Wetland Code. ' '' Please be advised, however, that no construction, sedimentation, or d~sturbance of any kind may take place seaward of the tidal and/or freshwater wetlands jurisdictional boundary or seaward of the coastal erosion hazard area as indicated above, or within 100' landward from the top of the bluff and/or wetlands jurisdictional boundary, without further authorization from the Southold Town Board of Trustees pursuant to Chapter 275 and/or Chapter 111 of the Town Code. It is your responsibility to ensure that all necessary best management practices are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction and Coastal Erosion Hazard Area, which may result from your project. This determination is not a determination from any other agency. If you have any further questions, please do not hesitate to call. Sincerely, Jill M[~Doherty, President Boar0t'of Trustees -- JMD:lms B.P, .BUILDING PERMIT EXAMINER CHECKLIST Applicant: ~ W~ Property Address: ~.~;~2~' City: Building Permits (Open/Expired): BP - -Z / C/0 Z- ~ ) Info: "'-"- BP __ -Z / C/0 Z- , Info: BP__-Z / C/0 Z- , Info: BP __ -Z / C/0 Z- , Info: BP __-Z / C/0 Z- , Info: Single & Separate Search Required? Y o eterminatlon: ILEQ. Lot Size: ACT. Lot Size: ~'~ REQ. Lot Coy. ~ ACT: Lot Cov. REQ. Front ~ ACT. Front REQ Side ~ ACT. Side ~ REQ. Rear ~ PROP. Rear REQ. Height ~ ACT. Height I{ ~.~, ~_ $1~5 ~ A ~ T ~ - Watterfront?l~or N? ~ If yes, water body: ~ ~ Panel# ~ Flood Zone: ~'~ Bulkhead/Bluff Distance: - ADDITIONAL APPROVALS REQUIRED Suffolk County Health: Y or N- If yes, *Bed#: __*Date: / / *Permit#: - If no, certification required: Y or N Received: Y or N By: NYS DEC: vu~-Decgans Y orO- Date: / / Permit #: Trustees: Y q~Date: Southold Southold ZBA: Y or~- Date: / Southold Planning: Y or~ Date: Town Landmark C of A: Y o~,N~TE: Notes: Permit #: Permit#: Permit #: / *Date Submitted: ~- g~lO Date Reviewed: 10-~- I 0 Estimated Cost: Zone: Conforming? ~'-'~. ~ Pre COs? Town Septic: Y or NJ Letter - Notes: or NJ Letter - Notes: - Notes: - Notes: *NYS CODE Compliance (page 2)~r N Fee Structure: Calculation: Foundation: SF 1. ( SF)- ( SF)= SF X $ _=$ First Floor: SF + Initial Fee: Second Floor: SF + Addition9l Fee ( ): Other: SF 2. ( SF)- ( SF)= SF X $ =$ Total: SF + Initial Fee: + Additional Fee ( ): c~O0 , O0 .~ /~-W F~"~'~" . TOTAL: NEW YORK STATE CODE COMPLIANCE CHECICLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: O~ . Groun~l Snow Load: I~0 , Weathering: Severe __ ..Frost Depth: 36" __ Design Temp: 11 ·Iee Shield Underlay: YES USE/OCCUPANCY CLASSIFICATION: HBIGI-~IT/FIRE AI~A: TWE OF CONSTRUCTION: DESIGN C~TE~: ENG~E~D~SC~T~ ~L F~G DESIGN ELEME~S: ~ ItE~ERS: Y~ W~L ST~: Y~ CEDING JOISTS: Y~ FLOOR JOISTS: L~BER SPECIES ~D G~E: Y~ Wind Spee& 120MPH Seismic Design Category." B . Termite: M~H Decay: Fio0d Hazards: GI1LDERS: YIN ROOF RAFTERS: Y/lq WINDOW AND DOOR SCHEDULE: .MISSLE TEST REQUIREMENTS: ON EGRESS 5.7 S.F.: Y/iN LIGHT 8%: Y/N 5rENT 4 %: NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FI2P,_E PROTECTION EQUIPMENT: Y/N TRuss DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: YfN TOTAL COMPLIENCE(~)~/N (RETURN TO PAGE ONE) Town Hall Annex 51373 Main Road ILO. Box 117!t Southold, N Y I 1 !t71-0939 Telephone (631) 763-1802 15tx (631) BUIL1)IN(; I)EPARTMF;NT TOWN OF $OUTHOLD Janua~ 18,2011 Fair Winds LLC 225 Mountain Avenue Ridgewood, NJ 07450 RE: 4522 Peconic Bay Blvd, Laurel TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy __ Application of Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. __ Final Health Department approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) __ Trustees Certificate of Compliance. (Town Trustees #765-1892) __ Final Planning Board approval. __ Final Fire Inspection from Fire Marshal. __ Final Inspection from the Building Dept. Final Landmark Preservation approval. Building Permit:: 35916-Z windows Integrity Impact Windows and Doors Supplemental Instruction for IZ3 rated products )Use these instructions in conjunction with the detailed installation instructions included with each order. This instruction is a guide for placement and application of brackets and fastening methods for impact rated products. As always, read all in- structions thoroughly before beginning to install your impact window or door. Fasteners and Spacing Methods Casement, Casement Picture, Awning, Double Hung Picture and Outswing Doors: Requires fastening the window to the rough opening in one of two ways: 1. Installation Cllpa (specialized for each frame) AND Nailing Fin, Attach brackets to the unit jambs and head jamb with #7 x 5/8" wood screws 6" (152) maximum from each corner and 18" (457) maximum around the unit perimeter, Attach nailing fin 4' (102) from all corners and a maximum of 7" (178) apart around the rest of the unit perimeter. OR 2. Structural Brackets Attach to the jambs, head jambs and sill (windows only) following the attachment method and spacing specified with the instructions (enclosed with brackets). Direot Glaze Polygons: Attach with Structural Brackets only to the jambs, head jambs and sill. Follow the attachment method and spacing with the instructions (enclosed with brackets). See figure 1. Installation Clips and Nailing Fin Structural Brackets 6" (152) O" (152) 18" (457) 12" (3C5) Figure 1: F&~tenlng and gp~clng Methods, Structural Brackets or Inltall~tlon Clips with Nailing Fin 19971049 2008-05-20 .Installing the Window or Door 1. Using the screw holes in the clip as a guide, drill through the nailing fin with a 1/8" drill bit. this will give you the location of the screw holes when you fasten the unit to the rough opening, see figure 2. 2. All Impact Rated Windows and Doors: Must be adhered to the sill with a discontinuous 5/16" (8) bead of construction adhesive on the framing sill where it will contact the window or door frame sill? See figure 3. Leave approximately 2 (51) gaps on the ends. See figure 4. 3. Follow the instructions included with each order to properly place, square and shim the unit in the opening. When using structural brackets, wrap to the interior framing. Follow the instructions included with the brackets. Figure 2: Drill through clip and nailing fin. Construction adhesive Figure 3: Apply con~tru~tion edheMve to RO sill. 4. if you are using Installation Clips in conjunction with nailing fin, fasten the clips to the rough opening with 1 1/4" drywall screws. See figure 5. 5. Follow all finishing, flashing and sealing steps found In the Installation Instructions sent with your window or door order. Figure 5: Fimten ¢111~ through nallin9 fin. 1 Use APA rated AFG-01 spec, 0920 construction adhesive. Make sure the adhesive is compatible with all building materials and the unit frame. SECTION 08 16 73 ULTREX® CLAD WOOD PATIO DOOR PART 1 GENERAL 1.1 SECTION INCLUDES A. Ultrex~ clad wood sliding patio door and frame, complete with hardware, glazing, weather strip, screen, removable grilles, grilles-between-the glass, simulated divided lite, jamb extension, and standard or specified anchors, trim and attachments. 1.2 RELATED SECTIONS A. Section 01 33 23--Submittal Procedures: Shop Drawings, Product Data, and Samples B. Section 01 62 00---Product Options C. Section 01 63 00---Praduct Substitution Procedures D. Section 01 65 00~Praduct Delivery E. Section 01 66 00--Product Storage and Handling Requirements F. Section 01 71 00---Examination and Preparation G. Section 01 73 00~Execution H. Section 01 74 00--Cleaning and Waste Management I. Section 01 75 00---Starting and Adjusting J. Section 01 76 00--Protecting Installed Construction K. Section 06 22 00---Millwork: Wood trim other than furnished by door and frame manufacturer L. Section 07 92 00---Joint Sealants: Sill sealant and perimeter caulking M. Section 08 71 00~Door Hardware: Hardware other than furnished by door and frame manufacturer N. Section 09 90 00~Paints and Coatings: Paint or stain other than factory applied finish 1.3 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E 283: Standard Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors. 2. E 330: Standard Test Method for Structural Performance of Exterior Windows, Curtains Wails, and Doors by Uniform Static Air Pressure Differanca. 3. E 547: Standard Test Method for Water Penetration of Exterior Windows, Curtain Wails, and Doors by Cyclic Static Air Pressure Differential. 4. E 774: Specification for Sealed Insulated Glass Units. 5. C 1036: Standard Specification for Flat Glass. B. Window and Door Manufactures Association (WDMA): I.S.4: industry Standard for Water Repellent Preservative Treatment for Millwork. C. Sealed Insulating Glass Manufactures Association / Insulating Glass Certification Council (SIGMA / IGCC). D. Amedcan Architectural Manufacturars Association / Window and Door Manufacturars Association (AAMA / WDMA): 1. ANSI/AAMA/NWWDA 101 / I.S.2-97: Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Giass Doors. 2. 101/1.S. 2/NAFS-02: Voluntary Performance Specification forWindows, Skylights and Glass Doors/ E. Window and Door Manufacturers Association (WDMA): Hallmark Certification Program 08 16 73 - 1 Ultrex~ Clad Wood Patio Door- 2009 F. American Architectural Manufacturers Association (AAMA): 613: Voluntary Performance Requirements and Test Prccadures for Organic Coatings on Plastic Profiles. G. National Fenestration Rating Council (NFRC): 101: Procedure for Determining Fenestration Prcduct Thermal Properties. 1,4 SYSTEM DESCRIPTION A. Design and Performance Requirements: 1. Units shall be designed to comply with 101/I.S.2-97 and 101/1.S. 2/NAFS-02 (SGD-R30) rating. 2. Air leakage shall not exceed 0.30 cfm per square foot of overall frame when tested at 1.57 psf according to ASTM E 283. 3. No water penetration when tested at 4,5 psf according to ASTM E 547. 4. Units shall be designed to comply with ASTM E330 for structural performance when tested at the following pressures: (+/-45 1.5 SUBMITTALS A. Shop Drawings: Submit shop drawings under provisions of Section 01 33 23. B. Product Data: Submit catalog data under provisions of Section 01 33 23. C. Samples: 1. Submit corner section under provisions of Section 01 33 23. 2. Include glazing system, quality of construction, and specified finish. D. Quality Control Submittals: Certificates: Submit manufacturer's certifications indicating compliance with specified performance and design raquirements under provisions of Section 01 33 23. 1.6 QUALITY ASSURANCE A. Regulatory Requirements: Emergency Egress or Rescue: Comply with requirements for sleeping units of [IBC International Building Code] [BOCA Basic Building Code] [Southern Building Code] [Uniform Building Code] ]. 1.7 DELIVERY A. Comply with provisions of Section 01 65 00. B. Deliver in odginal packaging and protect from weather, 1.8 STORAGE AND HANDLING A. Prime or seal wood surfaces, including surface to be concealed by wall construction, if more than thirty (30) days will expire between delivery and installation. B. Store door panels fiat on a level surface in a clean and dry storage area under provisions of Section 01 66 00, Seal unfinished top and bottom edges of door panels if stored at the job site more than one (1) week. C. Condition doors to local average humidity before hanging. 1.9 WARRANTY A. Doors shall be warranted to be free from defects in manufacturing, materials, and workmanship for a pedod of ten (10) years from purchase date. B. Door glass shall be warranted to be free from defects in manufacturing, materials and workmanship for a pedod of twenty (20) years from purchase date. PART 2 PRODUCTS 2.1 MANUFACTURED UNITS A. Description: Factory assembled Ultrex~ Patio Door, as manufactured by Integrity Windows and Doors, Fargo, North Dakota or Roanoke, Virginia. 08 16 73 - 2 Ultrex® Clad Wood Patio Door - 2009 2.2 FRAME DESCRIPTION Interior: Clear pine exposed surfaces. 1. Kiln dded to a moisture content no greater than twelve (12) pement at the time of fabrication. 2. Water repellent preservative treated in accordance with ANSI / NWWDA I.S.4. B. Exterior: Fiberglass reinforced (UItrex~) clad 0.080 inch (2 mm) thick. C. Composite frame thickness: 1-1/16 inches (27 mm). D. Frame width: 4-9/16 inches (116 mm). Beige fiberglass reinforced plastic (Ultrex~) sill with oak interior sill liner. 2.3 PANEL DESCRIPTION Intehor: Clear pine. 1. Kiln dried to a moisture content no greater than twelve (12) percent at time of fabhcation. Panel comers feature half lap joint. 2. Water repellent preservative treated in accordance with ANSI / NWWDA I.S.4. B. Exterior: Fiberglass reinfomed plastic (UItrex®) clad 0.080 inch (2 mm) thick. C. Composite panel thickness: 1-3/4 inches (44mm). D. Rail height dimensions: 2-5/16 inches (59 mm). 2.4 GLAZING Select quality complying with ASTM C 1036. Shall comply with 16 CFR 1201 Safety Standard for Architectural Glazing Materials. Insulating glass SIGMNIGCC certified to performance level CBA when tested in accordance with ASTM E 774. B. Glazing Method: 3/4 inch (19 mm) Tempered Insulating Glass. C. Glass Type: [Lol? - 272® Argon gas] [Lo~3 - 366® with Argon gas]. D. Glazing Seal: Silicone bedding, interior and exterior. 2.5 FINISH A. Exterior: Factory baked on acrylic urethane. 1. Color: Stone White; Pebble Grey; Bronze; Evergreen; Cashmere. B. Interior: Treated bare wood; White interior factory finish. 2.6 HARDWARE A. Handle set: High pressure zinc die-cast single point non-keyed handle / lock with Almond Frost snNVhite. A Brass Substrete with a single point non-keyed handle/lock is sued for the products with PVD finished inclucing Satin Nickel; Oil Rubbed Bronze; and Brass. Interior and Exterior finish will always be the same, color ,must be specified. B. Rollers: Two adjustable steel roller assemblies per operating panel. Two ball bearing wheels per roller assembly. Maximum vertical adjustment: 5/16 inch (8 mm). 2.7 WEATHER STRIP Full perimeter frame weather strip. Operating panel sealed to frame with bulb gasket and leaf weather stdp, bottom of panel weather stripped with ddp seal and fin seal pile weather strip. Stationary panel sealed to header with flexible leaf weather strip. Meeting stiles sealed with interlock and fin seal pile weather strip. 2.8 JAMB EXTENSION A. Furnish jamb extension 6-9/16 (167 mm) factory installed (shipped loose) 5-5/16 (135 mm); 6-13/16 (160 mm) shipped loose. B. Finish: Treated bare wood; White intedor factory finish. 08 16 73 - 3 Ultrex~ Clad Wood Patio Door - 2009 2.9 INSECT SCREENS A. Extruded aluminum sliding frame 0.045 inch (1.1 mm) thick. Top hung miler assembly with stainless steel ball beadngs in nylon wheels, top rollers adjustable up to 3/8 inch (10 mm). Frame to have edge mounted wool pile bug stdp. B. Screen mesh: t8 by 16, Charcoal fiberglass, C. Frame Finish: White; Pebble Gray; Bronze; Evergreen; Cashmere. D. Flush mounted ddged nylon handle on both sides of screen. Ridged PVC glide. 2.10 REMOVABLE GRILLES A. 3/4 X 15/32 inch (19 mm X 12 mm) pine. 1. Pattern: Rectangular. 2. Finish: Clear pine; White intedor factory finish. 2.11 GRILLES-BETWEEN-THE-GLASS (GBG) A. Manufactured from aluminum in an 11/16" (17mm) wide contoured profile placed between the two panes of glass. Available in rectangular cut, prairie cut 9 lite.. 1. Colors: White (white intedor and exterior); pebble (white interior and pebble exterior); bronze (white intedor bronze exterior); Evergreen (white interior and evergreen exterior); Cashmere (white intedor and cashmere exterior). 2.12 SIMULATED DIVIDED LITES (SDL) A. 7/8" (22 mm) wide. No internal spacer bar. 1. Exterior muntins: Extruded Ultrex. Available in rectangular and prairie lite cut patterns. Praide lite pattern - nine lite. Cottage lite cut with a horizontal daylight opening of 10". Size limitations may apply to prairie lite cut, or Cottage lite cut availability a. Color: Stone White; Pebble Gray; Bronze; Evergreen; Cashmere. 2. Intedor muntins: Clear pine; (White interior factory finish). 2.13 ACCESSORIES AND TRIM Installation Accessories: 1. Factory installed nailing fin at head and side jambs. 2. Installation Brackets: 6-3~8 inches (162 mm); 9-3/8 inches (238 mm); 15~318 inches (390 mm). 3. Mullion kit: Mullion kit for field assembly of units. Kit includes: Instructions, aluminum pins, mulling tin, sealant foam tape, installation brackets, screws, interior mullion trim and nailing fin connectors. PART 3 EXECUTION 3.1 EXAMINATION A. Verification of Conditions: Before Installation, verify openings are plumb, square, and of proper dimension as required in Section 01 71 00. Report frame defects or unsuitable conditions to the General Contractor before proceeding. B. AcceptanceofConditions: Beginning of instailation conflrrns acceptance of existing conditions. 3.2 INSTALLATION A. Comply with Section 01 73 00. B. Assemble and install doors and frames according to manufacturer's instructions and reviewed shop drawings. C. Set door sills in full bed of sealant; install backing material and sealant at head jamb and side jambs, and as specified in Section 07 92 00. Do not use expansive foam sealant. D. Install frames and stationary panels as required. E. Install sill support before using door. F. Install accessory items as required. 08 16 73 - 4 Ultmx~ Clad Wood Patio Door - 2009 G. Use finish nails to apply wood trim and mouldings. 3.3 STARTING AND ADJUSTING A. Adjust door to work freely with hardware functioning properly. Re-adjust at completion of project if directed. 3.4 CLEANING A. Remove visible labels and adhesive residue according to manufacturer's instructions. B. Leave doors and glass in a clean condition. Final cleaning as required in Section 01 74 00. 3.5 PROTECTING INSTALLED CONSTRUCTION A. Comply with Section 01 76 00. B. Cover doom and frames during painting or other construction operations that may cause damage. C. Protect sill from damage by chemicals, solvents, paint, or other construction operations that may cause damage. END OF SECTION 08 16 73 - 5 Uitrex~ Clad Wood Patio Door- 2009 STEFFENS RESIDENCE: REPLACEMENT WINDOWS SCHEDULE [ Original Original New (ea.) New (ea.) Frame Size Frame Size Frame Size Frame Size Window # Location, Quantity Type Width* Hei,qht* Width. Hei.qht 101 Foyer 2 Polygon DS 47.5 22 45 21 102 Liv Room 4 Casement 29.25 60 28 59.125 102 Liv Room 4 Transom 29.25 17,5 28 15.75 103 Liv Room 1 Casement 29.25 60 28 59.125 103 Liv Room 1 Transom 29.25 17.5 28 15.75 104 Liv Room 1 Casement 29,25 60 28 59.125 104 Liv Room 1 Transom 29.25 17.5 28 15.75 105 Liv Room 1 Casement 29~25 60 28 59.125 105 Liv Room 1 Transom 29.25 17.5 28 15.75 106 Liv Room 1 Casement 29.25 60 28 59.125 106 Liv Room 1 Transom 29.25 17.5 28 15.75 107 Liv Room 1 Casement 29.25 60 28 59.125 107 Liv Room 1 Transom 29.25 17.5 28 15.75 108 Liv Room 1 Casement 29.25 60 28 59.125 108 Liv Room 1 Transom 29.25 17.5 28 15,75 109 Liv Room 1 Casement 29.25 60 28 59.125 109 Liv Room 1 Transom 29.25 17.5 28 15.75 110 Liv Room 1 Casement 29,25 60 28 59.125 110 Liv Room 1 Transom 29.25 17.5 28 15.75 111 Liv Room 1 Casement 29.25 60 28 59,125 111 Liv Room 1 Transom 29.25 17.5 28 15.75 112 Din Room 2 Polygon DS 2@41.5 & 53.5 25.5 41 25 112 Din Room 1 Polygon DS see above see above 53 25 113 Kitchen 1 Casement 36 60 36 59,125 114 Kitchen 1 Casement 36 60 36 59.125 201 Mast Bdrm 1 Casement 29.25 43 28 43.25 202 Mast Bdrm 2 Casement 29.25 49 28 47.125 203 Mast Bdrm 4 Casement 29.25 60 28 59.125 204 Mast Bdrm 2 Casement 29.25 60 28 59,125 204 Mast Bdrm 1 Picture 41 60 39 59.125 205 Bedrm #3 2 Casement 29.25 60 28 59.125 206 Bedrm #3 1 Casement 29.25 60 28 59.125 207 Bedrm #3 1 Casement 29.25 60 28 59.125 208 Upst Bath 1 Casement 29.25 43 28 43.25 209 Bedrm g4 2 Casement 29.25 55 28 55.125 210 Bedrm ~ 1 Casement 29.25 55 28 55.125 301'* Mast Bdrm Triangle 108 55 108 55 302** Mast Bdrm Triangle 108 55 108 55 Door # A*** Foyer 1 Inswing French 36 81.5 35.5 81 B Liv Room 1 Slide French 72 81.5 71 82 B Liv Room 1 Transom 72 17.5 71 15.75 C Din Room 1 Slide French 72 81.5 71 82 C Din Room 1 Transom 72 17.5 71 15.75 D*** Rear Hall 1 Inswing French 36 81.5 35.5 81 E Mast Bdrm 1 Slide French 72 81,5 71 82 E Mast Bdrm 1 Stationary Door 36 81.5 32.3125 82 F Bedrm #3 1 Slide French 72 81.5 71 82 * Approximate frame size based on closest measurement without opening ** Manufactured by Parrett Manufacturing - aluminum clad *** Marvin MTO door - aluminum clad, the wall - needs to be field verified. Young & Young, Land Surveyors NOTE: B=MONUMENT FOUND ELEVATIONS SHOWN HEREQN ARE FROM ACTUAL SURVEY AN9 ARE REFERENDED TONSVD(MSL 1999). SURVEY FOR HENRY STEFFENS 8~ LINDA STEFFENS At: LAUREL Town of: SOUTHOLD Suffolk County, New York Surf. Co, Tox Map: iI000 I 128 I 4 I 19 JULY I, 1996 MAY 30 1996 MAY 91, 996 AUG, 15, 995 ,JULY 6,[995 0CT. 19~1994 SCALE : JOB NO. : 9z~- 0607 SHEET NO. 1 OF 1 BENC~ OUTDOOR 5HO1U~R 40'-2" O2OCA [) 0 't'-IO I/2' CATI I~DR/Id_ CEIL. IH "1 k'3AT I' U 5OFF 2'-z T-IO 112" HEIGHT OF SOFFIT T~ FOYER FLOOR[ IllBUL~T~ AT 8~1T HETGHT] IX~ TIG CEDAR 8' C.H... OPEN TO SECOND FLOOR OPEN II 1'O 1 ,,At,llql.) F~ I ~.D'-o" '17,:: .7:7::",:' -&"( .... 3~ JCl5 FD ('1 FIRST P'L()OR PLAN- ~ 5K38'28 -MqD~RSF-N ~;'i] 9'-8 I/2" 24~4CC~ b STONE ~BOYE :LOOP. /.] ,,_[, .... IVINCt · A DROP q' C,FL /TJI D,~ ,IOIST5 V. C ¢.t. floor 3~'~OCA ~ D~7OCA i' 3'-~ I/2" Il ~ 11 3-~ I,'2" /3'--~ 3/'F -~ ....... ~r ........... ~4 .......... ~ --- 7 ': / COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TOWN ZBA SOUTNOLD TOWN PLANNING BOAR{) SOUTHOLD TOWN TBOSTES N,Y,& DEC UNDERWRITERS CERTIF~T~! REQUIRED ~ ~,~ APPROVEDA,q NOTED . NOTIFY BUILDING DEPARI~V~'NT AT 765-1802 8 AM TO 4 ~ FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION. TWO REQUIRED FOR POURED CONCRETE 2 ROUGH - FRAMING, PLUNI~ING, STRAPPING, ELECTRICAL & CAULKING 3 INSUI.ATION FINAL - CONSTRUCTION & ELECTRICAl. MUST BE COMPLE'rE FOR C,O AU. CONSTRUCTION SHALL ~ ~HE REQUIREMEflTS OF THE CODES OF NEW YORK STATE NOT RE~I:~)NSIB~ FOR ~¢.¢4 OR ODt4GTRI, IG~ON E~ORG. P,, DR~UIII'IG TITLE: dOE~, 5'f'EFFEN5 RESIDENCE PECOI'IIC BAY BLVD. LAUREl., ;'lt~[U YORK TOUJN OF 5OL]THOLD SCTHtr ~RCHrTECT~ DONALD A. DENIS HAIN ROAD AQUEIBOGLIE, N.Y. ~1/.)'t2:2-$~11 DATE , ll/21/q~ ,~CALE , 11'4" "I'-O" dOE) biO: ~142~. Dte, AIIJItlG IlO. _E RCTPOFING J" ~ r 1 ~ 18- "l' ,r" ' . d CA TH~F~AL FLU,SH 5~¥NE HEAR'f kf' I/2" PLY~D.F~x 2XJO R~ ATTIC 'x % DECK OVER HE RD / 8TEFFENs L~UREL. NEI~ TOBN OF 8OUTHOLD $CTH~IOOO-I2e-4-1~ ARCH~EcT~ DONALD A. DiENIE, P.O.Box 1~41~ HAIN ROAD AOUEt3OGLIE, N.Y. '34;11 -45 VERTICAL II II II II SIDING II FIXED INSDL, GL 'rRAXSoH.L:I L] L] EAST EII_EVA-I:IC N DECK ASPI-IALT SHINGLE ROOFING SKYLIGHT tO~JER ENCLOSURE FIXED INSUL. DECK DE:CK N OE~-Ft-t ELEVA I ION r'~ pq DRADING TITLE! JOB~ 5TEFFEN$ RE..~IDENCE PECONIC BAy BLVD LAUREL, NE[ti YORK TOIiIN OF SOUTHOLD .5C TI'I~ IOOO-128-4Hq ARCblITECT~ DONALD A. DENIS P.O.BOX B~,5 HAIN ROAD AQUEBOGUE, N,'r. f~l,')q2:2-~BII 5TAHP REVISIONS: DATE LEAD FLASFIING ASPHALT SHINGLE ROOFING ASPHALT 511THGLE ROORIH& SKYLIGHT SKYLIGHT 5HOU]ER El CEDAR LATTICE VER ¥1CAL SIDING IJJOOD DECK _L i L.(-:. COPPER FL,,SIIIIIG Sff LICCO ~- ASPHALT ROOPIHG SHINGLE5 I/ ~'% ....................... - .-27 -. .... ~;.,'"' _./~" ~ CEDAR FACIA C\SOFf:I'I'S f~'rl ,AL FIEI_DSTONE PI[TCHED BACK TO FLt]~5 STAIR TO ~ELLAR I I I _EE_-2--2 L:LTL: VERTk 51DING RA1L1NO VERTICAL ID1NG ~ , E LLIE$ T ELEVATION VERTICAL SIDTNG FIXED TR ANSOil h ...,LITH tEI,.,t:VA] ION DRAUIING TI'rLE~ 5TEFFENS RESIDENCE PECONIC BAT BLVD LAUREL, NEUJ ¥OR~ TO~N OF SOUTHOLD ~RCHI'rEC'T'~ DONALD A. DEr'II8 P.O.BOX !;/, !i; HAIN ROAD AQUEBOGUE. N.Y. (~:I&)122-3511 ,STAtIp REVI~IONS~ DR~IIIIftG t~O.