Loading...
HomeMy WebLinkAbout35907-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-34812 Date: 01/21/11 THIS u~KTIFIES that the building SOLAR ELECTRIC PANELS Location of Property: 360 GREENFIELDS LA (HOUSE NO.) County Tax Map No. 473889 Section 59 Subdivision SOUTHOLD (STREET) (HAMLET) Block 4 Lot 5.7 Filed Map NO. Lot NO. conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 17, 2010 purs,,~nt to which Building Permit No. 35907-Z dated SEPTEMBER 30, 2010 was issued, and conforms to all of the requirements of the applicable proviDions of the law. The occupancy for which this certificate is issued is SOLAR PANELS ON AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to STEVE SUCIC of the aforesaid building. ( OWNER ) ~U~I~O~COUNTY DEPART~T OF H]~ALTHAPPROVAL N/A ELEt-rKICAL CE~TIFICATH NO. 35907 10/15/10 PLI~ERS C~KTIFICATION DA'r~u N/A ~u/th~Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35907 Z Date SEPTEMBER 30, 2010 Permission is hereby granted to: STEVE SUCIC PO BOX 1951 SOUTHOLD,NY 11971 for : INSTALLATION OF ELECTRIC SOLAR PANELS TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 360 GREENFIELDS LA County Tax Map No. 473889 Section 059 Block pursuant to application dated SEPTEMBER 17, 2010 Building Inspector to expire on MARCH SOUTHOLD 0004 Lot No. 005.007 and approved by the 30, 2012. Fee $ 200.00 'Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey °f pr°perry with accurate location o f all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S_9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Pl?ming Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey o£ property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant, if a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $50.00, Additions to dwelling $50.00, Alterations to dwelling $50.00, Swimming pool $50.00, Accessory building $50.00, Additions to accessory building $50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate ofOecupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Old or Pre-existing Building: New Construction: Location of Property: House No. Street Owner or Owners 0fProperty: .~-J ~ V~__ Q"~( )C~ t C_ ... Suffolk County Tax Map No 1000, Section ,~'c~ Block Subdivision Health Dept. Approval: ' Planning Board Approval: Filed Map. Date of Permit. Applicant: Underwriters Approval: Request for: Temporary Certificate Fee Submitted: $ (check one) Hamlet Lot: Final Certificate: ~ (check one) ~' "/gq~gr~ant Signature 'l'o;~a~ Hall Anncx 54375 Main Road P.O. Box 1179 SouthoM, NY 11971-0959 Telephol~e (631) 765-1802 Fax (631) 7(;5-9502 ro.qer.richert~town southold.ny, us BI ~ILDING 1)EPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Steve Sucic ~,ddress: 360 Greenfields Lane City: Southold St: NY Zip: 11971 ~uilding Permit #: 35907 Section: 59 Block: 4 Lot: 5.7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE 3ontractor: DBA: GO Solar Inc LicenseNo: 35972-me SITE DETAILS Office Use Only Residential ~ Indoor ~ Basement ~ Service Only ~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 3 ph Hot Water GFCl Recpt Main Panel NC Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment: 1 ac disconnect Notes: Ceiling Fixtures ~~][~] HID Fixtures Wall Fixtures I I Smoke Detectors Recessed Fixtures CO Detectors Fluorescent Fixtur~ Pumps Emergency Fixture Time Clocks Exit Fixtures I I TVSS photovoltaic system, consisting of 20 Kyocera panels, I Xantrex Gt 3.8 inverter Inspector Signature: Date: Oct 15 2010 81-Gert Electrical Compliance Form TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION REMARKS: ~//~ i/'~2 DATE~ INSPECTOR~ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAr,', 'l' INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ FRAMING / STRAPPING [/~FINAL Pacifico Engineering PC PO Box 1448 Sayville, NY 11782 www. pacificoengineering.com Engineering Consulting Ph: 631-988-0000 Fax: 631-382-8236 engineer@pacificoengineering.com Janua~ 13,2011 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Steve Sucic 360 Greenfields Lane Southold, NY 11971 I have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2007 NYS Building Code, and ASCE7-05, specific to the fastening of panels to the roof, to comply with the NYS code re: 120 mph winds. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer JAN 20 BLDG. DEPT. TOWN OF SOUTHO[D TO%n Of SOUTHOED BUIEDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined Cd, 20/° / Approved ~/.ff~), 20 /0 / Disapproved a/c Expiration BLDG DEPT. TOWN OF SOUTHOLD a. [his apphcatzon MUSI De col PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Plamfing Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: { Building Inspector PPLICATION FOR BUILDING PERMIT Date 9 /l'~ ,20 ,O INSTRUCTIONS tpletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. f ( g pp or name, ifa corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~t'P~l/~,~ ~'~ f.- t G (As on the tax roll or latest deed) If applici~t is a,.siorlLoratio~ sigtttature of duly. authorized officer (Name and title of corporate offiker) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be, done' House Number Street Hamlet County Tax Map No. 1000 Section~'~q Bi~,ck' t~¢ .-,,a Lo~ '~'7 Subdivision Filed Map No. :~g {o 3/~ Lot State existing use and occupancy of premises~,9.d i~nded use and occupancy of proposed construction: a. Existing use and occupancy /O~0,S t t:~St-e , b. Intended use and occupancy ~ 0..g ?-~O~)'o-~, - 3. Natureofwork (check which applicable): New Building. Addition.._-- Alteration ~q~p. air , Removal Demolition Other Wqrk 4. Estimated Cost ~ ~ 5~ 'Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units_.~-~mber of dwelling units on each floor~ If ~ara~o, numbor of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Hei§ht. Number of Stories Rear _Depth Dimensions of same structure with alterations or additions: Front Depth. Height Number of Stories Rear 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front J*~O ! Rear / ,5~ ! Depth a2 ~Tt q~ t Name of Former Owner 10. Date of Purchase 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO ~e' Will excess fill be removed from premises? YES NO~/~4.. 14. Names of Owner of premises ,5kv~,~t, Ct¢ Address .... Address Phone No Name of Architect h ~- ""' Name ofContractor~ 0 ~e)[~P~ '~/O C-- Address '~7;Zer~ 15 a. ls this property within 100 feet ora tidal wetland or a freshwat E NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet ora tidal wetland? * YES__ NO.~'~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO,/'~'' .... · IF YES, PROVIDE A COPY. STATE OF NEW YORK) COUNTY OFS~c~l ~_~)S: ' (~ ~ ~'~7 ~ ~;/?/1"6/ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)Heisthe O~ ,C~ntr~ ~r~'- (Co acto, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be pertbrmed in the manner set forth in the application filed therewith. Swora to before me this~ J a~y pua~.~ll~ff~~ .'."" .m~fm ~gn pp t Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.~ THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A ~ ~ ~'{. .~ ~7 STORM-WATER, GRADINGt DRAINAGE AND EROSION CONTROL pLAN Dlsfi`lct Secnon BI0~S lot CERTIFIED BY A DESIGN PROFESSIONAl. IN THE STATE OF NEW YORK. SCOPE OF WORK - PROPOSED CONSTRUL:I'ION ITEM # / WORK ASSESSM~a'NT Yes No a. What is the Total Ama of the project Parcels? 1 Will this Project Retain All storm-Water Run-Off (IncludeTotalAreaofallParcelslocatedwithinf~ 6~J'~ GeneratedbyaTwo(2")lnchRainfallonSite? the Scope of Work for Proposed Construction) ~" J (This item will include all mn-off created by site (S.F. / Acres) b, What is the Total Area of Land Cleadng clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed Site improvements and the permanent creetlon of construction activity? ~S.F. / Ac~s) 0 impervious surfaces.) 2 Does the Site Plan and/or Survey Show All Proposed PROVIDE BRIEF PROJECT DESCRIPTION O'm~ Addl~,.e ~,s. N.~) Drainage Structures Indicating Size & Lccation? This /~Z'I.,~.. Item shall include alt Proposed Grade Changes and and sediment control practices that will be used to ~" I ~/$4~4,4. 8~15[,5 .~ 4:~.0 Ky'o~'~.~l- 3DoestheSitePlanend/orSun/eydescdhetheerosionJ item must be maintained throughout the Entire  · Excavation where there is a change to the Natural · Existing Grade involving more than 200 Cubic Yards of Matudal within any Parcel? 5EncompassingWill this ApplicatiOnan Require Land Disturbing Activities Area in Excess of Five Thousand (5,000 S.F.) Square Feet of Ground Surface? 6 .s there a Natural Water Course Running through the Site? Is this Project within the TruStees jurisdiction General DEC $WPPP Requirements: or within One Hundred (100') feet of a Wetland or ;ubmission of a SWPPP is required for all Construction activities involving soil Beach? disturbances of one (1) or more acres; including disturbances of less than one acre that 7 Will there be Site preparation on Existing Grade Slopes are pan of a larger common plan that will ultimately disturb one or more acres of land; which Exceed Fifteen (15) feet of Vertical Rise to including Construction actislties involving soit disturbances of Isss than one (1) acre where One Hundred (100') of Horizontal Distance? the DEC has determined that a SPDES permit Is required ~or ctom~ water discharges. SWPPP's Shall meet the Minimum Requirements of the SPDES General Permit 8 Will Driveways, Parking Areas or other Impervious tsr St~rlll Water Discharges fi`ora Construction activity - Permit No. GP-0-10-001 .) Surfaces be Sloped to Direct Storm-Water Run-OffL~ 1. Trte SWPPP shall be prepared prior to the submittal of the NOI. 3~e NOI shall be into and/or in the direction of a Town right-of-way? submitted to the Depadment pdor to the commencement of construction actNlty. 2. The SWPPP sbafl describe the erosion and sediment control practices and where 9Will this Project Require the Placement of Material. mquin~l, post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any I I constructed to reduce the IXfllutents In storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder identify potential sources of p~lulton which may reasonably be expected to affect the STATE OF NEW YORK, ~ CO _ I // ThatI ~x,,~ ~.~ .~...,-~ being duly sworn, deposes and says that he/s ~e is the app] cant for Permit, Owner and/or representative of the Owner or Owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are txue to the best of his lu~owledge and belief; and that the work will be performed in the manner set forth in the application filed herewith. Sworn to before me this; Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 ,~..ax (631) 765,-,95(}~. ro,qer.richert(O~,town.soumom.n¥, us BUILDING DEPARTMENT TOWN OF SOUTHOI.r~ APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Company Name: Name: License No.: Address: Phone No.: Date: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cress Street: *Phone No.: Permit No.: Tax Map District: 1000 Section: ~ Block: 1~' Lot: *BRIEF DESCRIPTION OF WORK (Please Pdnt Clearly) (Please Circle All That Ap~51y) *Is job ready for inspection: *Do you need a Temp Certificate: Temp Information (If needed] *Service Size: 1 Phase *New Service: Re-connect Additional Information: YES / NO Rough In Final 3Phase 100 150 200 300 350 400 Other Underground Number of Meters Change of Service Overhead PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form SUFFOLK COUNTY HEALTH ! SINGLE FAMILY DWELLING 7 H.D. REF. DATE THE SEWAGE DISPOSAL.AND WATER SUPPLY FACILITIES FOR THIS LOCATION HAVE SEENF T FOUND TO BE SATIS ~iO~IO~_.F~Az ~..~. ~.. '1 Ohl~at~r ldnnngemen 4 otlon -- SUFFOLK CO. HEALTH DEPT. APPROVAL H.S. NO. STATEMENT OF NTEN_T THE WATER SUPPLY AND SEWAGE DISPOSAL SYSTEMS FOR THIS RESIDENCE WILL CONFORM TO THE STANDARDS OF THE SUFFOLK CO. DEPT. OF HEALTH SERVICES APPLICANT SUFFOLK COUNTY DEPT. OF HE A L-T~ SERVICES -- FOR APPROVAL O! CONST R UCT ION ONLY DATE: , ~ppROVED: , ,,,, ~FF~K CO. TAX MAP ~TION: DIST. ~CT. BL~K ~L. OWNERS ADDRESS: ~ -). ~ ,. _. .~ ~ ,) DEED: L. ~/A P- TEST HOLE STAMP SEAL RorlER ILK VAN TULL, ~.C. LICENSED LAND SUI~VEYOR$ GREEN.PORT NE:W YORK THE NEW VALUE FRONTIER KD210GX-LP HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC MODULE K IOEERa USTEB HIGHLIGHTS OF KYOCERA PHOTOVOLTAIC MODULES Kyocera's advanced cell processing technology and automated production facilities produce a highly efficient multicrystal phetovoltaic module. The conversion efficiency of the Kyocera solar coil is over 16%. These celL~ are encapsulated between a tempered glass cover and a pottant with back sheet to provide efficient protection from the severest environmental conditions. The entire laminate is installed in an anodized aluminum frame to provide structural strength and ease of installation. Equipped with plug-in connectors. APPLICATIONS KD210GX-LP Is ideal for grid tie system applications. · Residential roof top systems · Water Pumping systems · Large commercial grid tie systems · High Voltage stand alone systems · etc. QUALIFICATIONS · MODULE: UL1703 listed · FACTORY: ISO9001 and ISO 14001 QUALITY ASSURANCE Kyocora multicrystsl photovoltaic modules have passed the following tests. · Thermal cycling test · Thermal shock test · Thermal / Freezing and high humidity cycling test · Electrical isolation test · Hall impact test · Mechanical, wind and twist leading test · Salt mist test · Light and wster-exposure test · Field exposure test LIMITED WARRANTY · ~ 1 year limited warranty on material and workmanship ~20 years limited warranty on power output: For detail, p~ease refer to "category IV' in Warranty issued by Kyocera (Long tenm output warranty shall warrant if PV Module(s) exhibfts p~a.~r output of less then 90% el the odginal minimum ~ated power spscifiod at the time of sale within 10 yearn and less than 80% ~thin 20 ~ars after the date of sale to the Customer. The power output values shell be those measured under Kyocera's standard measurement coaditlons. Regarding the warranty conditions in detail please refer to Warranty issusd by Kyocera) ELECTRICAL CHARACTERISTICS Current-Voltage characteristics of Photovoltaic Module KD210GX-LP at various cell temperatures Current-Voltage characteristics of Photovoltaic Module KD210GX-LP at various irradiance levels 0803 SPECIFICATIONS KD210GX-LP · Physical Specifications Unit: mm 946 (37.2in.) · Specifications · Electrical Pea~ormarme under Standard Test Conditions (*STC) Maximum Power (Pmax) 210W (+5%/-5%) Maximum Power Voltage (Vmpp} Maximum Power Currant itmpp) Open Circuit Voltage (voc) Short Circuit Current itsc) Max System Voltage Temperature Coefficient of Voc Temperature Coefficient of Isc 26.6V 7.90A 33.2V 8.58A 600V · Electrical Performance at 800W/m=, *NOCT, AM1.5 Maximum Power (Pmax) 148W Maximum Power Voltage (Vmpp) 23.5V Maximum Power Current (Impp) 6.32A Open Circuit Voltage (voc) 29.9V Short Circuit Current (Isc) 6.98A · Cells Number per Module I 54 Length x Width x Depth 150~e(59,1in)x99~m~A~in)x3~ll.~n) Weight 18.5kg(40.81bs.) Cable (+)76~mm~.gin),(-)1840mm(72,~) Length x Width x Depth 100~n(3.~njx10~m(4.3in}xlSmm{0.an) *Operating Temperature -40'C ~90~C Maximum Fuse 15A Please contact our office for further information KSlBEERR KYOCER^ Corporation · KYOCERA Corporation Headquarters · KYOCERA Solar, Inc. · KYOCERA Solar do Brasil Ltda. · KYOCERA Solar Pty Ltd. · KYOCERA Fineceramics GmbH · KYOCERA Asia Pacific Pta. Ltd. 298 Tlong Bahru ROad, #13-O3/O5 Central plaza, Singapore 188730 TEL:(65)6271*0S00 FAX:(65)6271 =0600 · Kyocera Asia Pacific Ltd. Room 801-802, Tower 1, South Seas Centre, 75 Mody Road, T$imshatsui East, KowIoon, Hong Kong TEL:(852)2723-7183 FAX:(852)2724-4501 · KYOCERA Asia Pacific Pre. Ltd., Taipei Office 1 OF, NO. 66, NanPJng West Road, Taipel, Telwan TEL:(886) 2-2555~3609 FAX:(886)2-2559-4131 · KYOCERA (Tianjin) Sales & Trading Corp. (Bailing Office)Room 2107, Bel lng Huabin International Building No.8 Yong An Dong L, J an GUO Men Wai Road, Chao Yang District, · KYOCERA Korea Co., Ltd. Kyocera reserves the right to modify ~ese specifications withe ~t notre LIF~I 10A0711 -SAGM The Xantrex Grid Tie Solar Inverter (GT Series) is designed to convert photovoltaic (PV) electricity produced by solar modules into utility-grade power that can be used by the home or sold to the local electrical utility. Offering high efficiency (up to 96.0 %), clean aesthetics, high reliability, and a Iow installed cost, through ease of installation and integrated features, the Gl. Series is a proven, high-frequency design in a compact enclosure. The Gl' Series may be installed as a single inverter, for a single PV array, or in a multiple-inverter configuration for large PV arrays. Technology ~ AnNE£c~mp~iant~integratedDC/ACdisc~nnect~standardintheGTSeries~e~iminatestheneed for external DC (PV) disconnects, and in some jurisdictions, AC disconnects · Large heat-sink offers extraordinary heat dispersion without the need for a cooling fan ~ Liquidcrysta~dis~~ay(LCD)pr~videsinstantane~usinf~rmati~n-p~wer~eve~~dai~yandlifetime energy production, PV array voltage and current, utility voltage and frequency, time online "selling ", fault messages, and installer-customized screens ~ LCD vibration sensor allows the tap of a finger to turn bacldight on and to cycle through display screens ~ Free PC software for remote monitoring and system troubleshooting available online Installation ~ Flexible module selection and sizing due to wide PV input MPPT tracking voltage range ~ Lightweight and versatile mounting bracket ~ EasyaccessDC(photovoltaic)andAC(utility)terrninalblocksimplifieswiring ~ Rugged NEMA 3R inverter enclosure allows reliable indoor and outdoor installations Performance ~ Best-in-class efficiency to maximize solar system return on investment ~ Accurate MPPT tracking ensures maximum energy harvest under any conditions ~ FCC Part B compliance provides less external electronic interference Serviceability , lO-year standard warranty ~ Sea~edinverterenc~~surecanbequick~yseparatedfr~mthewiringb~xa~~~wingDC/ACc~nnecti~ns to remain intact in the unlikely event the inverter needs to be serviced Standard lO-year warranty Xantrex Technology Inc. Customer Service~Technical Support Toll free: 1-800~70~707 www,xantrex,com Xantrex GT Series Grid Tie Solar Inverters Models GT5.0 GT4.0N GT3.3N GT2.8 Max. AC power output 5000 W AC output voltage (nominal) 240 V AC output voltage range 208V 240V 208V I 240V 208V 240V 208V 4500W 4000W 3800W ' 3300W i 3100W 2800W 2700W 208V 240V 208V I 240V 208V 240V i 208V 211-264Vac 183-220Vac 211-264Vac 183-229Vac 211-264¥ac ; 183-229Vac 211-264Vac 185-229Vac AC frequency (nominal) 60 Hz AC frequency range 59.3 - 60.5 Hz Startup current 0 Adc Ma~ output oveecurrent protection 30 A 25 A i 20 A 15 A Total hon~onic disto~on (THD) < 3 % < 5 % Power factor > 0.99 % (at rated power), > 0.95 % (full power range) Low: 235 Vdc / High; 550 Vdc 240 - 480 Vdc Low: 235 Vdt / fligh: 550 Vdc i Low: 200 Vdc/ High: 550 Vdt Vdc Low: 193 Vdt / High: 550 Vdc 22.0 Adc 20.0 Adc i 17.5 Adc 1g,5 Adc 15.4Adc 14.9 Adc Max. array short-circuit current 24.0 Reverse-polarity protection Sho~<iKuit diode Ground-fault protection GF detection, IDIF > I A Max. inverter efficiency 95.9% 95.5% 96.0% 95.7% 95.9% 95,6% 95.0% 94.6% CEC efficiency 95.5% 95.0% 95.5% 95.0% 95.5% 95.0% i 94.0% 93,5% Night-time power consumption 1 W Operating t~mperature range -I 3*F to + 149*F (-25*C to +650C) Endosure type NEMA3R (outdoor rated) Inverter weight 58.0 lb (25.8 kg) 58.0 lb (25.8 kg) 49.0 lb (22.2 kg) 49.0 lb (22.2 kg) Shipping weight 65.0 lb (272 kg) 65.0 lb ~7.2 kg) 57.0 lb (25.9 kg) 57.0 lb (25.9 kg) Inverter dimensions (H x W x D) 28 1/2 x 16 x 5 314" (724 x 403 x 145 mm) Shipping dimensions (fl x W x D) 34 x 20 1/2 x 10 5/10' (866 x 518 x 262 mm) Mounting Wall mount (mounting bracket included) Input and output terminal AC and DC terminals accept wires sizes of #14 to ~ AWG PV / Utility disconnect Eliminates need for extemal PV (DC) disconnect. Complies with NEC requirements Cooling Convection cooled, fan not required Display BacklS, two-line, 16-character liquid c~stal display provides instantaneous power, daily and lifetime energy production, PV a~ay voltage and cunent, utility voltage and frequency, dme online "selling", fault messages, and installe~-customiza ble screens Communications Integrated RS232 aed XanbusTM Pd45 communication po~s Wiring box PV, utility, ground, and communications connections. 11~e invetter can be separat~J from the widng box Warranty 10-year standard Model name (negative ground) GT5.0-NA-240/208 UL-O5 i G?4.0N-NA-240/208 UL-O5 i GT3.3N-NA-240/208 UL-05 GT2.8-NA-240/208 UbO5 Part number (negative ground) 864-1009 864-1008 ! 864-1C06 864-1001 Positive ground inve~e~ are also available PV MODULE FRAMING AND MOUNTING SYSTEM FOR PITCHED ROOFS Module Compatibility Use Sunl~ame with ?V modules from these major manufacturers: BP Solar, GE Energy, Isofoton, Kyocera, Mitsubishi, ?hotowatt, RWE Schott, Sanyo, Sharp. Call UniRac or your PV dealer for manufacturers not listed. Code Compliance SunFrame is designed to comply with the Uniform and California building codes when installed according to SunPrame installation instructions. Call UniRac conceming status of International Building Code compliance. Components ~ Inter-Module Rails support modules as little as 2.125 inches above the roof. ~.~ Full Length Cap Strips secure modules and finish the array topside forming a gap-free frame. Seft- tapping screws at 16-inch intervals provide the holding power. ~ Push-Fit End Caps neatly finish the rail ends. ~ L-Feet attach directly to asphalt shingle roofs and support the rails one-haft to three-quarters of an inch above the roof surface to provide convective ventilation. O Splices safely extend rails. O Aluminum or Steel Standoffs (optional) in a range of heights sup- port L-feet above file or shake roofs. UniRac offers appropriate flashings. Clear or dark finishes on all visible above-roof components, from L-feet to screw heads, match the frames of your PV modules. Component Spedfications Rails, cap strips, two-piece standoffs, splices, and L-feet: 6105-T$ aluminum extrusion. End caps: UV resistant plastic. One-piece standoffs: Service Condition 4 (very severe) zinc-plated welded steel. Fasteners: 304 stainless steel. www. unir ac,corn See our SunPrame page for complete information: pricing, installation instxuctions appropriate to your build- ing code, and minimum requirements for the number and type of modules you plan to mount. UniRac, Inc. 3201 University Boulevard SE, Suite 110 info@unirac.com Albuquerque NM 87106-5635 USA 505.242.6411 505.242.6412 Fax Pub 050206.1ds · February 2005 © 2005 UniRac, Inc. All fights reserved. PV MODULE FRAMING AND MOUNTING SYSTEM FOR PITCHED ROOFS KD210 KD210 KD210 KD210 KD210 KD210 KD210 KD210 KD210 KD210 KD210 KD2~ South Roof Section A GENERAL NOTES mean roof height 14 ft pitch 5 in/12 RETAIN STORM WATER RUNOFF 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE 11.THE OWNER SHALL SELECT ALL FI~IS" MATERIALS AND COLORS. roof rafter 2x8 PURSUANT TO CHAPTER 236 SITE pRIO~ TO STARTING TO WORK AND SHALL FAMILIARIZE 12 THESE ~WINGS AS iNSTRUMENtS OF SERVICE AR~ AND SHALL rafter spacing 16 in CC AGREE Wl~ ~ME. FOR ~IC' THEY ~E ~DE IS EXECUTED ~ NOT. THEY ARE Reflected roof rafter span14.3 ff ~,S,C~.~t~SO~OCCU,*,~.~NS,~CTJ~ TH~S,,~C~XCE,TS~,E~,T~,W,,~,~,OW~m Table R802.5.1(1) max allowable 16.8 ff ~.~,.~o.~ ~.~ ~o.~..~,o.. UNDERWR FE ~ S C E RTiFJCATE ~r~,~y~lor~Nc I CONDUIT DATE%~ .... 1[~ .....~....,.~:~tl t ~ '~ ~ L~KW~HE" NOTIF~ BUILDING DEPARFMENT I ~'~~ 765-1802 8 AM TO 4 PM FOR Tile ~ .... ~ ~.oo,.o~cu.~.u ~ METER ~. . FOLLOWING INSPECTIONS . ~-,~*~JusT~s,,~. us~ ~ 1. FOUNDATION - TWO REQUIRED . .~ f o.E.~.~.. ~o.~-.~. FOR POURED CONCRETE .... ~ .. w, I ~~" ' 2. R~GH. F~MING, PLUMB,NG, Loc~ was... SERVICE ~. ~.~ ~I .~.~-~ PANEL ~ ~ STRAPPING. ELEC~ICAL & CAULKI~ G ~'~-~ ~ ; . - ~ ~ -- 4. FIN~. CONS~TION ~% . - ~ .~, ~ C~Sm~ SHALL ~ - .~r p... RETIREMENTS 0F THE CODES OF NE t ~GN OR ~ON ER~RS. N.T.S. ~ ~ ~~, ~ISER DIA~ SHOWN FOR REFERENCE ~PICAL CONNECTION DETAIL 1 ~ ~"~*'" ~"~*~ To my best belief and information the work in this d~ument is accurate, conforms with the Revis~n N.T.S. *.u~c*~,*c,s~ governing codes appli~ble at the time of submission, confo~s with reasonable standards ~PICAL CONNEXION D~AIL · ALL ROOF PENE~ONS ARE TO 8E SEALED of practi~, with the view to ~e safeguarding of life, health, prope~ and public welfare, Revision 2 PV PANEL w~ SI~FLEX OR E~UIVA~NT SEA~NT and is the responsibili~ of the licensee. Revis~n ~s per A$CET, Me~hod ~: ~ (f~ ~-2) ~. ~ ~A I (t~b~ ~) ~ CLIMACTIC AND Wind Sp~d, Live Icad, point pullout fastnet ' ~*'"~' GEOG~PHIC DESIGN Catego~ 3 sec gust, pne,30 ~, Fastener ,,. f~: CRITERIA mph ASCE 7, psf load, lb spaci.g a~o.g ~V~ Roof Section A C 120 58 572 5/16" ,ia screw. 3-1,2" length 48~'~ ~:~j, ' : PROPOSED SO~ ENERGY . __ ,- 8 ~ / .... ~ENE~L N~S, ROOF SE~ON, DATA. PETAI~ AND SPECS o 15~_5, 'I ROOF LAYOUT ~-~o-,*-,: A PA I I 0 EN INEERIN~---L~_~ PANEL: KD210 , ~ve rev,~ ~e .~fing stru~ure at the sublet addr~s The st.~u. ~n sup~, the add~na, weight LENGTH: 59.1 in WIDTH: 39 in C~e, a~ ASOET~5 ~n insta[l~ in a~rdan~ ~th the ~n~a~umr's ins~ions WA~S; 4200 I NOrD 0 C