HomeMy WebLinkAbout35536-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUP/LNCY No: Z-34636 Date: 10/26/10 THIS CERTIFIES that the building FUEL TANK REPLACEMENT Location of Property: 7400 MAIN RD (HOUSE NO.) (STREET) County Tax [4ap NO. 473889 Section 122 Block 7 subdivision Filed Map No. Lot No. LAUREL Lot 1 (HAMLET) conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 7, 2010 purs,,~-t to which Building Permit No. 35536-Z dated MAY 6, 2010 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is TANK REPLACEMENT WITH FIRE SUPPRESSION SYSTEM AS APPLIED FOR. The certificate is issued to AMAC INC of the aforesaid building. ( OWNER ) SUFPOLK C~)I~YDEPAR~I~TOF IIF~KLTHAPP~OVAL N/A R~-~-KICAL C~KTIFICATE NO. 35536 09/27/10 PL~MBEi~S CERTIFICATION DA'r~u3 N/A Authorl zed SIgnature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUII~)ING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35536 Z Date MAY 6, 2010 Permission is hereby granted to: AMAC INC PO BOX 1491 MATTITUCK, NY 11952 for : TANK REPLACEMENT WITH FIRE SUPPRESSION SYSTEM AS APPLIED FOR; LOCATION OF DISPENSERS TO REMAIN at premises located at 7400 MAIN RD County Tax Map No. 473889 Section 122 Block pursuant to application dated APRIL 7, 2010 Building Inspector to expire on NOVEMBER 6, LAUREL 0007 Lot No. 001 and approved by the 2011. Fee $ 250.00 Authorized Signature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF $OUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPAI This appliCation mU~t b~ filled in by typewriter or ink and submitted to the Building A. For new building or new use: '1. Final survey 0f prope~y with accurate location of all buildings, property lines, s~ ,~'~. ~'~ natural or t~pographic features. .2. Final Approval from Health D~pt. of water supply and sewerage-disposal (g-9 form). 3. Approval of e~e/~ie~ iustallation from Board of Firo Underwriters. 4. Sworn statement from plumber c~ttLrying that the solder used in system ~ontaius less than 2/10 of 1% lead.. 5. Comm~ial building, i~dustrial buildin~ multiple residences and Simila~ buildings and installations, a C~tificate of Code Complianc~ from amhit~t Or engineer responsible for the building. '6. Submit Plnnning Board Approval of~:ompleted site plan r~quiremcnts. B. F~rexis~ng.bu~di~g~.(pri~r~Apr~9~957)n~n-~nf~rminguses~rb~i~dings~rad"pre~exist~ng~~duses: 1. Ac.~urat¢ survcyof prol~Oy, showing all property lines, streets, building and unnsnal natural or topographic 2. A pr°l~rlY completed applicatioa and ¢ouscnt to insp~t signezl by the applicant, i£ a C¢~ficat¢ of Oc~tpancy is d~ni~L, thc Building Insp~tor shall statethc reasons thcr~£or m' writing'" to thc apphcant' (L Fees 1. CeCil°ate °f Oc~:upancY - New dwelling $25.00, Additious to dwelling $25.00, Alterations to dwelling $25.00, Swimmtn~ pool $25..00, A.c~ssory building $25.00, Additions to accessory building :~25.00, Bnsinesses $50.00. 2. Ce~ific.~,~ ofOc~apancy, on Pr~-~xis~iag Building - $100.00 3. Copy ofCe~ificate ofOc~upartc¥ - $.:25 4. Upaat~d Ccrtificato of Occupancy - $50.00 5. Temporary Ce~tifi~t¢ o~Oeeupancy - Residential $15.00, commer~inl $ i $.00 -New Construction: Old or Pre-eXisting Building: House No, S~t O Subdivision (cheek One) Filed Map. Lot: ApPlicant: .~.~,/~-~ '/~C, Health DepL Approval: Planning Board APProval: Request for: Temporary C~rtificat¢ Fee Submitted: $ R c'l q q Undcrvaiters Approval: · Final Ce/tificate: (check one) T(mn Hall ,51375 Main Road P.O. Box 1179 Somhold. NY 11971-09,59 Tc:lcphonc (631) 76,5-1802 F~-x (631) 76,5-9,502 roger, richert~town.so uthold, ny. us BIIIL1)IN(; DEPAI/TMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION ssued To: Empire Petroleum ~,ddress: 7400 Main Rd City: Laurel St: NY Zip: 11941 ~uilding Permit #: 35536 Section: 122 Block: 7 Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE 3ontractor: DBA: T-D Electric License No: 4460-e SITE DETAILS Office Use Only Residential ~ Ind°°r I~ Basement [~ Service Only~ Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 3 ph Hot Water GFCI Recpt Main Panel A/C Condenser Single Recpt Sub Panel NC Blower Range Recpt Transformer Appliances Dryer Recpt Disconnect Switches Twist Lock Other Equipment: Ceiling Fixtures [~1 HID Fixtures Wall Fixtures I I Smoke Detectors Recessed Fixtures~l CO Detectors Fluorescent Fixture I'~ Pumps Emergency Fixtures~ Time Clocks Exit Fixtures LI TVSS install new fuel tanks and dispensers, 2 tanks, 4 dispensers, 8 overhead explosio~ proof lights, work done with required hazordous location equipment Notes: Inspector Signature: Date: Sept 27 2010 81-Cert Electrical Compliance Form Fire Guard of Long Island, Inc. Glenn Kamm - NYC Master Fire Suppression Piping Contractor - Class C Uc. No. 0266 40-8 Burr Drive, Deer Park, NY 11729 (631)242-5315 Fax (631)242-4945 83 Jewett Ave., Staten Island, NY 10302 (718)981-7872 Email-lire guar dli(q'op tmium.net VIA FAX- # (631) 369-164g September 9, 2010 Town of Southold Building Department Town Hall Southold, NY 11971 Attention: Bob Fisher RE: EMPIRE GAS STATION 7400 Main Road Laurel. NY Dear Mr. Fisher: Please be advised that Rm Guard has completed the installaUon of the fueling area fire suppression system as shown on approved plans. The system was successfully tested, tagged and placed into operation on September 9, 2010. Said system was designed and installed in accordance with NFPA 17, "UL 1254" and the manufacturer's UL listed manual. Sincerely, FIRE GUARD OF LONG ISLAND, INC. Glenn Kamm, President Suffolk County Lic. l17A Fire Suppression System-Closed Circuit TV Systems-Fire Extinguishers De.qi om-In ~t a11 a tinn ~-T~.q~octinn ~ SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICE TOXIC LIQUID STORAGE REGISTRATION FORM Principal Property Tax Code District I1 10 10 I 01 OFFICI,N_ USE ONLY h o ol ,oc, New Change __ Add F,-- Facility Name M&S Petroleum Tank Owner A~ ]%~L, ~8uleyman Ilgin'% No. Street 7400 RTE 25 No. Street Old Countr mat'i, number in left column Community State Zip Laurel N.Y. 11952 Community State Zip Riverhead 901 '- Designates cathodic protection SINGLE DOUB.E WALLED WN ~ FO P~neNo. I 631.298,5073 P~neNo. 631.369.5900 OFFICIAL CAPACITY (GALLONS) 15,000 8,000 7,000 Other Material (Specify) USE ONLY I certify that information on this application and all attachments have been reviewed and that, based on my inquiry of those Receipt No. I persons immediately responsible for obtaining the information contained in this application, I believe that the information is true, accurate, and complete. I understand that false statements made herein are punishable as.a Class A [nisdemeanor Am_., ~. .e. ~ .~;~'0..~ pursuant to Section 210.45 of the Penal Law. Dale~ e Title/ / '7/':;/L/D) I I Print Name Suleyman I19in Isignatu HMM003 Rev 2~88 t 8-z,~,~-,.s/e8 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631} 765-9502 SoutholdTown. Nor thFork, net Examined .~//e ~ 20 / ~ Approved ~ , 20 /b~ / Disapproved a/c Expiration /////~, 20 // PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planthng Board approval Survey Check Septic Form Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: APPLICATION FOR BUILDING PERMIT Date 4/1 ,20_ 10 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Pem~it. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate &Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the properby have been enacted in the interim, the Building Inspector may authorize, in writing, the extension &the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance ufa Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, OrdJmances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspect~ ~ (Signature of applfcYfit or name, if a corporation) 40 Doyle Ct. East Northport, NY 11731 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Contractor Name of owner of premises Ama¢, Inc. (As on the tax roll o If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number 7400 Street RTE 25 Hamlet Laurel County Tax Map No. 1000 Section 122.00 Block 07 Lot 001.00 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premise~ and intended use and occupancy of proposed construction: a. Existing use and occupancy Gasoline Service Station b. Intended use and occupancy_ Gasoline Service Station 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Fuel Tank Replacement (Description) 4. Estimated Cost $200,000.00 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling anits on each floor If garage, number of cars 7. Dimensions of existing structures, if any: Front 54 Ft. Rear 54 Ft. Height 14Ft. Number of Stories 1 Dimensions of same structure with alterations or additions: Front Depth. Height Number of Stories 8. Dimensions of entire new construction: Front Rear Height Number of Stories 9. Size of lot: Front 269.68 Ft. Rear 108.53Ft. Depth 265.28Ft. 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 1000 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO X 13. Will lot be re-gm&d? YES X NO __ 14. Names of Owner of premises Araac, loc Name of Architect Breslau Engineering P.e. Name of Contractor hland Pump & Tank Corp. If business, commercial or mixed occupancy, specify nature and extent of each type of use. commercial- Gasoline Service Station .Depth 29 Ft. Rear Depth Will excess fill be removed from premises? YES X NO__ Address 74ce Rte 25, Laurel, 11952 Phone No. Address1381st st., st.106, Llndenhurst, l~)ne No 631-592-0474 AddresS0 Doyle Ct., £. Nort hpofl, 11731phone No. 631-462-2226 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to prope~ lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO __ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY Frank DiAndrea being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the Contractor (Contractor, Agent, Corporate Officer, etc.) ~ of said owner or owners, and is duly authodzed to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to, before me this. . . -- ~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 76~-1802 FAX: (631) 76fl-9~02 www. northfork.net/Southold/ Examined ,20 Approved ,20 Disapproved Mc Expiration ,20 BUILDING PERMIT APPLICATION CHECKLIST Do you have or need lhe following, beforo applying? PERMIT NO. ~2) ~5~9 Board of Health 4 s~ of Building P~ platma~ Board approval Survey. Check Septic Form N.Y,S.D.E.C. Tmstees Contact: Mail to: Phone: ~ {~ ~ ~ ~ Building Inspector ~~- Date /~ ,20. ;0w~0Fs0u~ ~ ~ INSTRUCTIONS a. This application MUST be completely £fllad in by typewriter or in ink and submitted to tho Building In~ctor with 3 sets of plans, accurate plot plan to scale. Fee a~cording to schedule. b. Plot plan showing location of lot and ofbinltlings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall he kept on the premises available for inspection throughout ~e work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within ]2 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall he required. APPLICATION IS HEREBY MADE to the Building Department for the issuance ora Building Permit pursuant to the Buildi~ Zone Ordinance of the Town of Sonthold, Suffolk County, New York, and other applicable Laws, OrdirmnceS or Regulations, for the conslnaction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinanCeS, building code, housing code, and regulations, and to admit ~ (Sisnaha'~ o f appliean, an_t_t or mme~if a corporation) (M~ilin~ add~'~ss of applimmt) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremisns I"P'- f ~ ~-~-o ~ ~ ~ (As on the tax roll or latest deed) If applj~i~')t~orpo~amre of duly %uthorized officer / (N~d title of corporate offi~r) Bmlders License No. Plumbers License No. Electricians License No. Other Trade's License No. ~ ~, c= t=: o gt~ 1. Lo_~cafiffn of lund on which propose~l ~ork will be done: House Number Street Hamlet County Tax Map No. 1000 Section / 2.~_ Block 0--~ Subdivision Filed Map No. (Name) Lot 0 / o rO Lot 2. S~e existing use and occupancy of premises and inlended use and occupancy of proposed consm~,'pn.; ~.,, : b, Intended uso and occupancy 3. Nature of work (check.which applicable): New Buildi~ Repair Removal Demolition 4. F~timated Co~t / o,, o.o 5. ffdwoHing, nun~er of dwelling units If garage, number of cars Addition Aheratton , , ~on) fro ~ ~d ~ fling ~s ~p~) N~r of dwe~g ~ on ~ floor 6. If business, COmmercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rea~ Height Number of Stories U0p Dimensions of same structure with alterations or additions: Front , ,Rear Depth · ~, Height : Number of Stories 8. Dimensions of entire new conslmction.' Front Rear ' - , Depth, . Height Number of Stories ~ ·, 9. Siz~ of lot: Front R~r Depth , 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated: 12. Does proposed construction violate any zoning l~w, ordinance or rOgulatibn? YES__ 13. Will lot bo re-graded? YES NO Will excess fill be removed from pr~mi.~es? YES NO 14. Names of ,O~.. er of premises ~'~' ~ '; Name of Architect 15 a. IS this propen'y wi~in 100 feot of a gdal wetland or a freshwater wetlend? *YES NO * IF YES, $OU'II-IOLD TOWN TRUSTEES ~ D.E.C: PERMITS MAY BE REQUIP, B . b. Is this propen'y within 300 feet of a tidal wetland? * YES, NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. provid~ survey, to scale, with accura~ foun~_~on plan and distances to property lines. 17. ff elevation at any point on property is at 10 feet or below, must provide topographical dam on survey. · STATE OF ~ YORK) COUNTY OF~ ~_~/._ ~ ~y',~' /~/~- ~ ~ ~g ~y sworn, ~s ~d ~ys ~t ~ ~ ~c appU~ (~, A~ ~ ~. ~.) of ~ o~r ~ ~ ~d ~ ~ ~ m ~om or ~ ~o~od &o ~d wo~ ~ m ~ ~d f~ ~ ~p~o~; m LORRAINE ABRU~O Notaw Pubfic, State of New York No, ~42545 , _ Oualif~ in Suffolk ~un~ ~, ~ ~' ~ ~m~o~ ~ ~s Nov 30,~{ ~ COUNTY OF SUFFOLK STEVE LEVY SUFFOLK COUNTY EXECUTIVE DEPARTMENT OF HEALTH SERVICES Linda Mermelstein, M.D., MPH Acting Health Commissioner BUREAU OF ENVIRONMENTAL ENGINEERING APPROVAL NOTICE Breslau Engineering, P.C. Att.: Alexander M. Santino, P.E Re: SCDHS Job No. : SCDHS Fac. ID. No.: SCDHS File Ref. No.: Dear Mr. Santino: HM09-175R1 10-0049 13677 October 7, 2009 Your application for a permit to construct a project at M & S Petroleum, 7400 Rt25, Laurel, NY 11952 has been reviewed for compliance with Article 12 of the Suffolk County Sanitary Code. The application has been approved. Enclosed you will find the Permit to Construct. This permit has to be posted at the construction site during the construction. If you have any questions regarding the review process or need assistance, feel free to contact this office at (631) 854-2512 or email me at xiaoyu.chen(&suffolkcountyny.gov. Very truly yours, Assistant Public Health Engineer Bureau of Environmental Engineering Division of Environmental Quality OFFICI~ OF POLLUTION CONTROL · DMSION OF ENVIRONMENTAL QUALITY * 15 HORSEBLOCK PLACE * FARMINGVILLE, NY 11738 * Phone (651) 854~2512 Fax (631) 854-2505 Emaii: xiaoyu.chen~suffolkcountyny.gov PERMIT TO CONSTRUCT Toxic and/or Hazardous Material Storage Facility Suffolk County Department of Health Services Linda Mermelstein, M.D., M.P.H., Acting Commissioner SCHDS REFERENCE # 13677 SCHDS REGISTRATION # 10-0049 SCHDS PLAN # HM09-175R1 Date of Issuance: October 07, 2009 Permit Expiration Date: October 07, 2010 FACILITY NAME~~ ADDRESS: M & S Petroleum 7400 Rt25' Laurel, NY 11952 Your Application for Permit to Conhtmct a Toxic or Hazardous Material Storage Facilities for the above referenced site has been reviewed for compliance with Articles 7 & 12 of the Suffolk County Sanitary Code. The appb~au6n has been approve~l. The 'i~ms bsted below and on the brick,of this Permit are conditions Of this Permit and have I~ be obse~ed flulVahg construction: A copy oftbe approved plan must be kept at the consumction site. A copy of this permit must be kept on display at the facility during construction. Safe construction practices must be followed during the installation of the st#rage facility(s). The storage facility(s) must be coustrile~ed in accordance with the approved plan. Any changes in design, materials or use requ~,s l~rior wffiten consent of both the design professional and the Office of Pollution Control. The cl~iges~ haye ~ be submitted in a form that is acceptable to the Office of Pollution Control. The contractor and/or dezign professional is required to inform the owner that the changes are being made. 4. The Office of Pollution Control has ~ ~_.ght to in/peet this inslallation at any time to verify its being coustmcted in compliance with this ~i~l~ The Office of Pollution Control must be contacted at 854-2523 at least 2 business days prior m commencement of any work to arrange for the required construction inspections. Contact the local building department and/or fire safety enforcement office for any additional requirements that may apply to your project. The storage facility cannot be placed into service until the Office of Pollution Control performs all required installation inspections and issues an interim permit to operate. The Office of Pollution Control reserves the right to revoke this permit as allowable by law. ISSUED BY: Bureau of Environmental Engineering Office of Pollution Control Glenn Kamm - NYC Master Fire Suppression Piping Contractor- Class C Lic. No. 0266 40-8 Burt Drive, DeerPark, NY 11729 (631)242-5315 Fax(631)242-4945 371 Metropolitan Ave., Brooklyn, NY 11211 (718)963-9769 VIA FAX #369-1649 May 5, 2010 Fire Marshal Town Hall Annex P.O. Box 1179 Southold, NY 1 I971-0959 RE: M & S Petxoleum (Empire) Main Road & Old Main Road Laurel, NY I AY 5 2010 BLDG. DEPT. TOWN OF SOUTHOtl) Dear Mr. Fisher: Please be advised that Fire Guard has been contracted to commence the design and installation of a new UL 1254 fueling area fire suppression at the above referenced location. Please contact me if any additional information is needed at this time. Sincerely, FIRE GUARD OF LONG ISLAND, INC. Glenn Kamm, President SOUTHOLD TOWN I FIRE INSPECTOR NOTES JOB: ~W~,~---~ (~A-~ '~,~ --L.-r~uCz-~.J. DATE: LOCATION: ~Ob '~o~ Z~ ~~ S/B/L: / / NotesPaper Page Suffolk County Department of Health Services PERMIT TO OPERATE A TOXIC OR HAZARDOUS MATERIALS STORAGE FACILITY This permit will expire upon the date specified or upon a change of the operator. This permit is not transferable and is granted subject to compliance with the provisions of Article 12 of the Suffolk Count,/ Sanitary Cede and 6 NYCRR Part 612 - 614. This permit can be revoked upon failure to follow the applicable provisions of these parts or comply with any special conditions of issuance. All unauthorized or accidental releases of toxic or hazardous liquids must be reported to tzhe Suffolk Count,/Department of Health Services at 631-854-2501 and to the NYSDEC Regional Spill Office at 631 ~.~/,-0323. FILE REFERENCE NO. FACILITY REGISTRATION NO. FACILITY NAME AND ADDRESS 13677 10-0049 EM&T INC/EMPIRE SERVICE STATION commoNs OF ISSUANCE: 7400 MAIN RD PO BOX 525 1. The listing of storage facilities accompanying latest renewal notice is EAUREL, NY 11948 hereby made part of this permit. .2. The owner/operator is responsible for all storage facilities listed in (1) OWNER/CORPORATE MAil,lNG ADDRESS above and that currenUy exist on site. 3. All leak detection, overfill and level alarm probes and panel boxes must be maintained in satisfactory working condition at all times. 4. All monitoring wells, alarm systems and emergency equipment must be AMAC INC checked periodically. A log of these checks must be maintained on site. 7400 MAIN RD PO BOX 1491 5. Inventory records and monitoring equipment logs must be maintained on site and presented to a representative of the SCDHS upon request. MATTrI'UCK, NY 11952 6. Access to the site is hereby granted to representatives of the SCDHS for routine compliance inspections dudn~l normal business hours. PERMIT ISSUING OFFICIAL ISSUING AGENCY AND CONTACT INFORMATION Division of Environmental Quality - Office of Pollution Control  /~'"'~ 15 Horseblock Place Farmingville, N.Y. 11738 /q"z~/,'~//'/ff./~'/~,,,~' Tel: 631-854-2519 Fax: 631-854-2505 DATE OF ISSUE EXPIRATION DATE COMMISSIONER 09/01/2010 08/31/2011 THIS PERMIT MUST BE CONSPICUOUSLY POSTED · .so~ m, ~ ~ ~ . · Btm ~n~ D~P~'UE~rr TOMflq OF ~o~ ' ~PPLICATION FOR F~ ~TRIC~ INSPECTIOH """ JOBSITE INFORMATION: **a~d~ress .- - *Cross Street: *Phone No.: Tax Map District: information) 100o Sec~on: ! .-}...-~ - *BRIEF DESCRIPTION OF WORK (Please Print. Clearly) L~t: [ (Please Circle Ali That Apply) *lejob ready for Inspection: .*Do you need a Temp Certificate: (~NO Temp-lnformation (ff *Sen~lce size: 1 Phase 3Phase *New Service: Re-connect Underground Additional InfOrmation: 82-Reqt.,e~ for Inspectkm Form Rough In Final 150 200 300. 350 400 Other Number of Meters Change of Service ~d .PAYMENT DUE WITH APPLICATION · OWNER4~: ' ' ' TOWN OF SOUTHOLD PROPERTY RECORD CARD ST.E~r 7~00 jE~_.TM t LAND IMP. TOTAl DATE SUB. LOT BUILDING CONDITION AGE ACR, · ,TYPE OF BUILDING NL:W NORMAL BELOW ABOVE FARJV~ Acre Value .. CB. MlCS. Mkt. Value Tillable Woodland DEPTH BULKHEAD DOCK FRONTAGE ON ROAD FP. ONTAGE ON WATER H~.~se Plot Tot~'~'/ ~ Meact~vk~nd Value Per Acre COLOR -TRIM /Y~/O' ~ ,r M. Bldg. Extension Extension Extension Porch- Garage Patio Tota! Foundation Basement Ext. Walls Fire Place I Beth Floors L~erior Finish Heat Type Roof Rec~eoflon Room I- .. ~Dormer Rooms Ist Floor Rooms 2nd Floor Drivewey Dinette LR, DR. BR. FiN, B THIS PERMIT IS VALID FOR THE FOLLOWING STORAGE FACILITIES ONLY SCDHS # LOCATION VOLUME CONTENTS 13 Under / Om 15,000 Gals. Gasoline 14 Under / Out 8,000 Gals. Diesel 15 Under / Out 7,000 Gals. Gasoline NOTE For up to 90 days after the Perrrfit to Construct expires, the permit is renewable. The job file will remain open for that period. If the Office of Pollution Contxol does not receive a renewal application with the appropriate fees within the 90 days, the file will be closed and a new application for a Perafit to Construct will have to be filed if the job is to be re-opened. All applicable filing fees will once again become due and payable. Issuance of t~s pernut does not supersede any exasting agreements w~th, o~r m.aad, a~s §~,~t~e Office of Pollution Control or any other government agency. The construction perloO;)doe~ not supersede any existing compliance dates agreed to, or mandated by, the Office of Pollution Control or any other government agency.. Issuance of this permit does not ~uthorize the ~se of the~storage facility(s) that are m wolation of the Suff011~ County Samtary Code or any other gover~iment code. S J Data/ Specification Sheet TYPICAL MAIN ISLAND PROTECTION 1. Fixed temperature electrica~ thermal detectors Electrical conduit protecting wiring Model ECH-Series Control Head Model PAC-10/200 Pneumatic Actuating Cylinder Pneumatic actuation line Model ATD-35/75 Agent Storage Cylinders 7. Fixed agent distribution piping 8. Model N-ATD Discharge Nozzles 9. Model RPS-M Remote Mechanical Pull Station General The ^ttendantTM Gasoline Station Fire Suppression System is a fire control system designed to aid and enable occupants to evacuate parked vehicles subjected to fire resulting from spilled fuel in the protected area of gasoline service stations. A secondary purpose is to exgnguish small spill fires in the protected area. Gasoline service station vehicte fueling area fires are unique hazards, having environmental and physicat vadables that can affect the estinguishing capability of The Attendant Gasorine Station Fire Suppression System. These variables include: 1. Unusust wind or weather conditions. 2. Spills that extend beyond the protected area. 3. Sources of ignition beyond the protected area. 4. Sources of ignition that continue past the end of the discharge. 5. Large trucks and unforeseen obstacles to the discharge pattern. System Operation ~ihe ^ttendantTM Gasatine Station Fire Suppression System has been · designed and tested to the September 29, 1998 revision of UL 1254 Standard for Pm-Engineered Dry Chemhtat Extinguishing System Units and is Listed by Underwriters Laboratories for main island protection and end-of-island protection. Tyco Safety Froducts 71 E- 752-3465 TM ^ modular concept of protection is used. ^ nozzle pair (called a "cluster") protects a specific hazard module determined by the hazard size and the cluster's positioning within the module. Sets of clusters are located to protect adjacent hazard modules that make up the hazard area. ^ dedicated, stored-pressure cylinder containing monoammonium phosphate-based dry chemical extinguishing agent supplies the clusters with the necessary fire fighting agent through a fixed piping natwon~. Electrical fixed temperature thermal datectom are strategicatry positioned over the dispenser island. These detectors monitor the ambient temperature of the hazard area, and initiate a signal in the event that the rated temperature is exceeded. The control head receives this signal and responds by initiating a pneumatic actuation system. This actuation system opens the valve assemblies on the agent storage cylinders and releases the agent into the discharge piping neWvork. A mechanic, a[ means of manually activating the system without electrical power is provided. This manual actuation may be either by turning the lever on the control head, or pulling the handle on a remote manual release device. Expanded capability is available to provide supervision of the detectionfintiiation circuit, remote elec'~rical manual actuation, gas dispenser shut down, and audible alarm. Optional equipment wilt enhance the basic system functions and be applicable when designing custom configurations to suit a particular customer's needs or to comply with local codes. July 15, 2004 Suggested Architect's Specifications 1. General 1.1 The fire exflnguishing system shall be the stored pressure dry chemical pm-engineered tixed nozzle type manufactured by Pyro-Chem. This system shall provide fur protection of the gasoline station vehicle fueling area(s) described and defined in drawing (Note drawing number and revision). 3.3 - Pneumatic actuation. The system shall have a PAC~erfas · Pneumatic Actuating Cylinder whose valve opens upon actJvaflon of the control head. The valve shall release nitrogen from the PAC cylinder into the pneumatic pipe and tubing network. This ntirogen shall depress a piston above the valve stem in each agent cylinder, opening each agent cylinder vane and releasing the pressurized agent. 3.4 - Manual actuation. The system shall have mechanical manual 1.2 The system shell be capable of automatic and manual actuation. It actuation capability requiring no electrical power. This is accomplished · shall be teated in ac(on:lance with the September 29, 1998 revision of · locally by twisting the handle on the cover of the ECH-Sehes Control U.L. 1254 Standa~ for Pm. Engineered Dry Chernlcat Head, or remotely by means of a Model RPS-M remote mechanical Extinguishing System Unit~, and be Listed by Underwriters Laboratories. The system shall bo installed and maintained in accordance wfth NFPA 17 Standard fur Dry Chemical Extinguishing · Systems, NFPA 30 Flammable and Combustible Liquids Code, the manufacturer's UL Listed Technical Manual, and all local and/or State Codes and Standards. 1.3 The system shall be designed for opecaiton at ambient · temperatures from -40°F to 120'F (-40 °C to 49 °C). 1.4 The system shall be designed for operation in a minimum 10 mile per hour wind. 2. Cylinder and Agent 2.1 - Agent. The extinguishing agent shall he Pyro-them · monoammonium phosphate-based dry chemical agent (ABC type). 2.2 - Cylindem. Steel cylinders manufactured, tested, and marked in > accordance wflh DOT 4BW350 shall bo used to store the extinguish- ing agent. Cylinder Models ATD-35 and ATD-75 shall be used with extinguishing agent fill weight of 35 lbs. and 75 lbs., respectively. All models are charged with dry nitrogen to 350 pstg at 70°E 2.3 - Cylinder valve. A pressure sealed poppet-type valve having a brass body, stainless steel stem with rubber seat washer, fuelbis > safety rst~f assembly, and pressure gauge shall be used on all agent cylinders. 2.4 - Cylinder bracketing. Cylinders shall he mounted vertically. The cylinders shall be secured by use of a steel mounting bracket affixed to a rigid bracket capable of supporting the weight of the filled cylinder and the concussion of cylinder discharge. 1. Actuation Controls 3.1 - Control Head. The syatem control heed shall include a Model ECH-Series Control Head. The control head shall be mounted directly on the valve of a pneumatic actuating cylinder. A carbon dioxide pilot cartridge that complies with MIL-C0601G shall be used as an integral component of the control head. Control head status shall be visually indicated by a SET/F~RED indicatur, 3.2 - Datectlon. The amlY~ect temperature of the hazard area shall bo monitored by fixed temperature electrical thermal detectors. Whe~ the temperature of the hazard area exceeds the rating of any detector, the detector shall close a normally open switch element w~thin the detector, sending a signal to the control head. This signal shall energize a solenoid in the control head which exercises the control head and actuates the system. pu[l station. 3.5 - Auxiliary o~tput. The system shall shut off power to all fuel dispensing units in the event of system actuation. This is accomplished · by means of dry contacts on a Model MS-DPDT micro switch installed · in the ECH-Serios Control Head. The micro switch may also he used fur auxiliary functions such as audiMa alarms or alarm signalling. 3.6 - Supervision. A Model SM Series Solenoid Monitor shall be used to supervise the integrity of all electdcel actuation c~rcutis, whether automatic or manual. · 3.7 - Manual electrical actuation (optional). The system can have electrical manual actuaiton capability. This is accomplished by the use of a Model RPS-E2 Remote Electrical Pull Station inataliad in the automatic detection circuit. 4. Distribution Nozzles 4,1 - Nozzles. The system shall utilize Model N-ATD Discharge Nozzles to distdbota agent throughout the hazard area. The quantity, location, and ohent~tion of nozzles shall bo in accordance with Pyro-Cbem, The Attendant Gasoline Station Fire Suppression System ~-Technical Manual, Part No. 550670. 4.2 - Nozzle covem. All nozzles shall be installed with nozzle covers to prevent furelgn maher from clogging the discharge nozzles. 5. Pipe and Fittings 5.1 - Pipe. Ail pipe shall be Scheduia 40 black, galvanized, chrome plated or stainless steel pipe in compliance with NFPA 17. All pipe ends shall be thoroughly reamed after cutting, and afl oil, chips, and debris shall be removed prior to nozzle instatlaiton. 5.2 - Fittings. Standard weight maliaable, gelvaelzed, chrome plated or stainless steel fittings shall bo used. ~. 5.3 - Size. All system pipe and fittings will be sized in accordance with the system Technical Manual. No substitute)ns are allowed. 5.4- * Joints. No joint sealant shatl be used in the discharge piping. Exception: Teflon tape may be used to ensure a snug fit. 5.5 - Straps. All system discharge pipe shall be securely fastened by means of pipe hangers and/or pipe straps. UL listed pipe hangers shall be used. 5.6 - Union. A union shall be installed in the discharge piping convenianfly dose to the cylinder valve to permit disconnection fur inspection and service. MODEL NO. ATD-35 ATD-7$ MOUNTING A B C D WEIGHT BRACKETSusED I 10.00 I 30.00 I 35.75 I 27.75 I 70Faa IMB-ATD~rMBU101 I 1zoo I ~4,7~ [ 40.so I 32.~ I 137g~ ~MB-ATDorMBU12I ALL DIMENSIONS IN INCHES PROPBRFY BINB PLAN NOZZFB MPP TYPIC,d- __/ PROPOSal2 LIGHT POLB (SxP) I ~_ 2~p o HBA-i' ~gB?UCi'OR ( Fyv) MPP If. bBVAT'ION (TYP) i~BTBCfOR SPACINd NOZZtB CLLIFTBP. (lq'P) NOZZLB 5PACIN5 PLAN VIP_-:W (TYP) 51i% KBY MAP N,T,5, APPROVAB5 UN? OP BLANI? AIM PfS, PL-AN VJBW N,T,5, ~AIN 5LANB e~-© MAX p/~,1 CLO~ NIPPLB - p/d-ri×l/ '4' CLO~B NIPPLB N-AT~NOZZLB ~ NOZZL~ MAIN 15BANI~ NQZZbU CLLISTBR UN? Off IFLANI?/ZONB NOZZLB CLLISTf-R NOZZLB !2B'FAIb N,T,5, ~/4" PlSCHARNB ON'FL. BT -~(2,~?, COPPBR TLItPlN~ C ACTLIATOR AT~-TS AT~-TS PAC-IO 9 e'-o t' *'-o ~l' e' mo MAIN 15LANI~ AIMIN5 POINT5 (TYP) UNI? ~LUVATION I?RY CHBMICAL- CYI.-INI~BR5 PNBLiMATIC ACTLIATION PBTAIL N,T,5, i4'~X 14"X 2" 16 dA.IdB 120 WHII~ ~LAdK COIL 5M-i2O PLIMP UdH-120 ~ I~ow HUAT CObLUCT'OP, I~TAIb N,T,5, ~U Nil- P-.At NOTB5 WIRINd 5CHBMATIC N ,i'5, I/2" CLOS~ NIPPLB I/2' 4¢' BLt 5YSTBM TO I~U ~ ~PYR. O-CHBM~ ATTBNI~ANT MOI~UI.- ATlaseS/7S AS APPROVU~ L.INI~UR LIB ~ STANI2AR. I;2 I~S4 far I0 MPH WINI2 CONI:21TIONS, HUAT I~UTUCTORS TO I~U ~PUN-WAB'~ MOI~BB I;;?-B~71~I ~° P--ATU ANTICIPATBI~, '~,ABI~ PLIUB 1::21SPUNS~RS SHAbB SHUT I~OWN LIPON SYSBM ACTIVATION, THURU SHAbB NO MANUAl- RBSUT OP THU I~ISPUKISIN~ 5YSTUM AVAIBAI~BU, THU I~ISPUNSURS 5HAbB NOT i~U CAPAI~BU OP I~UIN~ RBSTARTU~) LINTIb THU PIRB SLIPPRUSSION SYSTI~M IS TO OPUP--ATINN CONI21TION, ANY LINALITHORIZBI2 ACTION TAKBN TO RUSTORU THU 1~ISPUN- IN~ OPUP-ATION WITHOLIT PIRST HAVIN~ THB SLJPPRUSSION 5YSTUM RUSTORBI2 CONSII:2URUI~ A VIOBATION OP THU NUW YORK STATU PIRB PRBVBNTION COl~U, ALt PIPIN~ TO PB 5CHUI:2LIBB '40 ~AL-VANIZUI:2 STIr-Bt WITH ~00 b~ CBA55 ~AI. VANIZUI:2 MABBUAPBU IP. ON PITTIN~S, 5YSTUM TO I~B SIN~L-B ZONU PNULIMATIC RBBBASU LITIBIZIN~ I/~r"O,l:2, RUPRI~FcRATION %IPlNN ~ I/4" 4~° PBARU TYPU BRASS PITTINN5 CONPORMINN TO 5AU CYL-INI2BRS AR.U TO I~U PIL-L-UI2 WITH MONO AMMONILIM PHOSPHATU ( APC TYPU) CHAR~UI2 TO '~0 PSI~ WITH ~RY NITRONUN, NOZZBU CAPS At~.U TO l~U iNSTAL-¥UI~ APTUR PINAb TUSTINd:;i POR THB OPPICU, ANI~ MARSHAP 'S FIRE GUARD OF LONG ISLAND, INC. 40-8 BURT DRIVE - DEER PARK, N.Y. 11729 (631) 242-5315 FAX (631) 242-4945 REVISIBNS t::'~O-CH~M MOPBI-" AT~/7~" BMPIP, P,P,P,P,P,P,P,P, RB 5/5 ] ~R~WN ~Y, SCALE Ut L2S4 PIRB 5BPPRB551QN 5YS~M ~IN RO~ ~ Ob~ MAIN t M & S PETROl E UM MAIN ROAD & OLD MAIN ROAD LAUREL, N.Y. UNDERGROUND TAN' K R E P LAC :N T P R O J..F__. C T SITE HAlN KEY, MAP NO7 TO SCALE N ,/ // 4 PIPING, CONDUIT, WIRING, CABLES AND APPURTENANCES AT NO cOST TO E UTILiTiES, OWNERS, OPERATORS, tOES, W~RING, STRUCTURES, pIPiNG, ETC,''~'~ ONSTRUOTION WORK, THE CONT~ MS THAT MAY AFFECT THE WORK:' ~' MANUFACTURERS iNSTALLATiON INSTRUCTIONS. J A SIGN STAPING "NO SMOKING WITHIN 50 FEET" SHALL BE POSTED IN TH~ VICINITY OF ALL MOTOR FUEL DISPENSI~$~RE ~ 8. PoiNTS. REQUI~ 9. TANK PILLS SHALL BE COLOR CODED IN ACCORDANCE WITH THE AMERICAN PETROLEUM INSTITUTE'S SYSTEM OF OPEN~I IDENTIFIC/~TION AS IMPLEMENTED BY LOCAL CODES. I , LLS[..,-:; ' 11. ST~UCTdR~S~HAL~BEWASHED~FREEFL~W~N~AN~NF~RMT~AST~3~PA~.1~S~ZES8THR~UGHS~`~ LIST OF ABBREVIATIONS A.I .P. ABOVE FINISHED t-LOOP BLBO, BUILDING C.H.U. CO[4CRETE MASONRY UNIT COL COLUHN CONC. CONCRETE CDT. CONDUIT DIAH. DLANETER DWG. DRAWING EA EACH MECH. MIN. MFR. NO., # OVHD. REINF. REQ'O. MECHANICAL MANUFACTURER NUMBER '3, ~IdSIjL.A[LON NOT TO SCALE 4, FINAL ON CENTER OUTSIDE DIANET[~ O~RHEAD POLYV~NYL CHL~ 8'fATE. NOT REEPO REINFORCING REQUtRED JIRED MEET THE ~OFNEW FOR ERRORS, ELECT. ELECTRICAL, ELECTRIC SECTION EL., ELEV ELEVATION ~FE~' SPECIFICATION E.J EY, PANSION ,JOINT STL ' STEEL EXG. E×LSTLNG ' EXTERIOR ST. STL. ~ STAINLESS STEEL EXT. FOOTING THK. ' THICK FTG. _ TYP. ~ TYPICAL FLR. ~OuC~RE U.L. ' UNDERWRITERS LABS ,;c T,X ~**: ~ooo - ~.o - ~- o?o CV-I TITLE PAGE W/ KEY HAP SP-I EXISTING SITE PLAN A-I NEW TANK LAYOUT AND ~OUIPNENT LIST TANK -r-i T-2 M-I M-2 P-I HFC DETAILS-15K COMPARTMENTED DETAILS - 15K TANK PIPING SUMP DETAILS DISPENSER DETAILS PIPING LAYOUT AND PIPI qG DETAILS NOTES MANUFACTURER'S TANK DRAWINGS APPROVAL -, FOLK COUNTY DEPA BUREAU OF ENVIR( APPROVAL TO CONSTRU( These plans and specifl~tl~ and found to be in Sanitary Co~a (aqulrements submitted by the, expires on OCT,U APPROVAL DATE DRAWI N;G STAMP TMENT OF HEALTH SERVICEr:: NM ENTAL ENGINEERING 03 T SCOHS JOe NO. JE N 0 9 - have been reviewed ed upon iRfo~Tnaedn approval to constru~ TITLE DWG. NO PROJECT TITLE KEY~ MAP CV- SITE KEY MAP ~ UNDERGROUND TANK REPLACEMENT PROJECT ~COPE OF WORK DEMOLITION I. REMOVE TANK MAT 2. REMOVE DISPENSERS AND DEMO THE EXISTING PUMP ISLANDS, 5. REMOVE AND PROPERLY DISPOSE OF EXISTING SINGLE WALLED FIBERGLASS TANKS. &, REMOVE AND PROPERLY DISPOSE OF ALL UNDERGROUND PRODUCT, VENT AND STAGE II PIPING, 5. RESERVED B. RESERVED 7. RESERVED SITE PREP EXCAVATE TANS HOLE IN ACCORDANCE WiTH OSHA STANDARDS OR USE SHEETIND TO SUPPORT EXCAVATION WALLS. E. SAW CUT ASPHALT AND CONGRETEASNEEDED. B. EXOAVATE'PI:PING'TRENSHES, INSTALLATION I. FURNISH AND INSTALL ONE 15,000 GALLON COMPARTMENTED DOUBLE WALLED FIBERGLASS UNDERGROUND MOTOR FUEL STORAGE TANK, COMPARTMENT A SHALL BE AN 8K DIESEL TANK AND COMPARTMENT G SHALL BE A 7N PREM GAG TANK. 2. FURNISH AND INSTALL ONE 15,000 GALLON DOUBLE WALLED FIBERGLASS UNDERGROUND GASOLINE TANK. 5. FURNISH AND INSTALL ALL DOUBLED WALLED FIBERGLASS PRODUCT PIPING. USE SINGLE WALLED FRP FOR VENT AND VAPOR RECOVERY. &. FURNISH AND INSTALL ONE VEEDER ROOT TLS-BS0 ALARM pANEL W/PRINTER, 5. FURNISH AND INSTALL ALL LEAK DETECTION SENSORS FOR PIPING AND DISPENSER SUMPS, B, FURNISH AND INSTALL VEEDER ROOT MAGNETOREBTRICTWE PROBES FOR LIQUID LEVEL AND OVERFILL ALARM LEGEND PRODUCT LINES DIESEL U/G VENT LINES PROPERTY LINES WATER SERVICE SANITARY SEWER (SITE) TELEPHONE POLE (~ ELECTRIC SERVICE -- -- E GW MON WELL e STORM DRAIN GRATE {~ SOLID COVER FOR SANITARY POOLS CHAIN LINK FENCE x x WATER METER BOX (~ WATER TABLE INFORMATION ELEVATION OF LAND SURFACE: DEPTH TO WATER TABLE: 22.A FT 11.75 FT DEPTH TO GROUNDWATER WAS MEAEURED IN AN EXISTINE TANK BED NONTORING WELL. SEE EXISTING SITE PLAN FOR THE LOCAT[0N DF HIS WELL, 'HERE IS A NETWORK DF EXISTING GROUNDWATER NONITORING WELLS AT THIS SiTE RELATED TO A PREVIOUS GASOLINE SPILL WESTIGATION, THESE WELLS WILL SATISFY THE REC~U[REHENT TO LOCATE A GROUNDWATER HONITORING WELL DOWNSTREAH OF THE NEW TANK GED INSTALLATION. ANY PETROLEUM SPILL HON[TORING WELLS DAMAGED DURING THE COURSE OF iNSTALLING TEE NEW FUEL TANKS WILL HAVE TO BE REPLACED IN ACCORDANCE WITH NEW YORK STATE DEPAETHENT OF ENV[RONNENTAL CONSERVATION APPROVAL SITE PLAN NOTE: THE INFORMATION USED TO PREPARE THIS SITE PLAN WAS OBTAINED FROM A SURVEY COMPLETED BY JOSEPH A. INGEGNO, KS, LOCATED IN AOUEBOGUE, N.Y. THE SURVEY WAS COMPLETED ON SEPTEMBER 6, IGC7. THE SURVEY DOCUMENTS WERE PROVIDED TO THE ENGINEER BY ISLAND PUMP AND TANK CORP. ON MARCH 3, 2008. FLOOD PLAIN INFORMATION: A REVIEW OF FLOOD PLAIN MAP NO. 3BI05COL~81 G REVEALED THAT THE PROPOSED UNDERGROUND STORAGE TANKS WILL NOT BE LOCATED IN A FLOOD PLAIN, MAIN RD. & OLD MAIN RD. LAUREL, N.Y. \ / \ % (TVP ~) ~ EXST'® ~,~ ~AL EDGE OF RoAD EXIS ,,IN SITE PLAN GENERAL NOTES 1. ALL WORK TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL CODES AND IN STRICT ACCORDANCE WITH APPLICABLE NATIONAL FiRE PROTECTION ASSOCIATION AND NATIONAL ELECTRICAL CODE SPECIFICATIONS AND REQUIREMENTS. 2. ALL EQUIPMENT. WHEN APPLICABLE, IS TO BE LISTED AND LABELLED BY UNDERWRITERS LABORATORIES, INC. FOR THE INTENDED PURPOSE OF THE EQUIPMENT. 3. ALL MATERIAL SHALL MEET OR EXCEED MANUFACTURERS WRI~EN SPECIFICATIONS. 4. THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES AND EQUIPMENT ADJACENT TO THE WORK, SUPPORT AND RELOCATE IF NECESSARY ALL EXPOSED LINES AND MAKE COMPLETE RESTORATION OF DAMAGED PIPING, CONDUIT, WIRING, CABLES AND APPURTENANCES AT NO COST TO THE UTILITIES, OWNERS. OPERATORS, AUTHORITIES HAVING JURISDICTION AND THE ENGINEER OF RECORD. 5. THESE DRAWINGS DO NOT INDICATE ALL OF THE EXISTING EQUIPMENT, DEVICES, WIRING. STRUCTURES, PIPING, ETC. EITHER EXPOSED OR CONCEALED, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION WORK, THE CONTRACTOR SHALL OBTAIN AND/OR VERIFY THE EXACT LOCATION OF ALL EXISTING ITEMS THAT MAY AFFECT THE WORK. 6. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF THE VARIOUS SYSTEMS AND THE APPROXIMATE RELATIVE LOCATIONS OF THE EQUIPMENT, DEVICES AND OTHER ITEMS. 7. ALL EQUIPMENT SHALL BE INSTALLED/PIPED/WIRED IN STRICT COMPLIANCE WITH THE EQUIPMENTS MANUFACTURERS iNSTALLATION INSTRUCTIONS. 8. A SIGN STATING "NO SMOKING WITHIN 50 FEET" SHALL BE POSTED IN THE VICINITY OF ALL MOTOR FUEL DISPENSING POINTS, 9. TANK FILLS SHALL BE COLOR CODED IN ACCORDANCE WITH THE AMERICAN PETROLEUM INSTITUTE'S SYSTEM OF IDENTIFICATION AS IMPLEMENTED BY LOCAL CODES. INSTALLER SHALL FURNISH WRI~EN APPROVAL OF COMPLETED INSTALLATION FROM ALL AGENCIES HAVING JURISDICTION OVER THE WORK TO BE PERFORMED. tt. ALL PEA GRAVEL UTILIZED TO BED AND SUPPORT UNDERGROUND TANKS. R/RING. SUMPS AND OTHER BELOW GRADE STRUCTURES SHALL BE WASHED, FREE FLOWING AND CONFORM TO ASTM C-33 PARA 9.1, SIZES 6 THROUGH 8 NO MORE THAN 5% SHALL PASS THROUGH A NO. S SIEVE. 12. ALL WORK SHALL COMPLY WITH THE DEPARTMENT OF ENVIRONMENTAL CONSERVATION'S PETROLEUM BULK STORAGE REGULATION 6 NYCRR PART 612~14. LiST OF ABBREVIATIONS A.F.F. BLDG. BLK. C.M.U. COL CONC. CDT. DIAM. DWG. EA. ELECT. EL., ELEV, EXG. EXT. FTG. FLR. GA. ABOVE FINISHED FLOOR BUILDING BLOCK CONCRETE MASONRY UNIT COLUMN CONCRETE CONDUIT BIAMETER DRAWING EACH ELECTRICAL, ELECTRIC ELEVATION EXPANSION JOINT EXISTING EXTERIOR FOOTING FLOOR GAUGE iNSIDE DIAMETER MECH, MECHANICAL MIN. MINIMUM MFR, MANUFACTURER NO,, # NUMBER N.T.S. NOT TO SCALE C.C. ON CENTER ~ O.B. OUTSIBE DIAMETER OVHD. OVERHEAD P.V.C. POLYVINYL CHLORIDE REINF. REINFORCING REQ'D, REQUIRED SECT, SECTION SPEC. SPECIFICATION STL. STEEL ST, STL, STAINLESS STEEL THK. THICK TYP. TYPICAL U.L. UNBERWRITERS LABS W.W.M. WELDED WIRE MESH SC TAX MAP: 1000 - 122.0 - 07 - 01.00 INDEX TO DRAWINGS CV-I SP-I P-I TITLE PAGE W/ KEY MAP AND EXST'G SITE PLAN WITH NEW TANK LAYOUT PIPING LAYOUT AND PIPING DETAILS SITE PLAN NOTE: THE PIPING LAYOUT HAS BEEN REVISED TO COINCIDE WITH THE DISPENSER LAYOUT. THE ORIGINAL DISPENSER LOCATION WILL REMAIN THE SAME AS IS. THE DISPENSER ISLANDS Will NOT BE RELOCATED AS PROPOSED IN THE APPLICATION FOR A PERMIT TO CONSTRUCT THAT WAS APPROVED BY THE SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES ON OCTOBER 7, Z009 PURSUANT TO SCDHS JOB NO. HM0g-175RI. THESE DRAWINGS ARE SUBMITTED TO REFLECT THAT CHANGE FROM THE APPROVED PLAN, APPROVAL STAMP DRAWING TITLE PROJECT TITLE, KEY MAP AND EXISTING SITE PLAN DWG. NO. or-' NOZZLE (SEE NOTE I) BLENDER DISPENSER NEW OR EXISTING LUMINAIRE TO BE INSTALLED NEAR DISPENSER ISLAND FLEX ENTRY FITTING FOR 2' SINGLE WALLED FRP PIPE F/STAGE II VAPOR RECOVERY SHEARVALVEFORSTAGEII VApOR RECOVERy PIPING ~TABILIZER BAR FOR SECURELY DISPENSER W/ NEW DISPENSER SUHP AND FIRE SUPPRESION SYSTEM (3) w/ \ \ STATION LISIdTED SIONA©E EXST'© ITYP FUEL EXST'© VEEPER ROOF TLS-~50 PANEL W/ PRINTER TO REMAIN ISLANDO TO ONE-STCF-.Y DONVEN IENDE STOP. E W/SAI PS LiNK ENDLOSURE SANiTARy SYSTEI~ EXST'G STEE RAIL ,,0 o j ~' LISHT STANDhilON ~ // t ~..~ W/ TWO LUMIN~ $1'I'E I_AN NEW TANK LAYOUT N SCALE: I" = I0' EXST'G 1,000 OALLON ABOVE ®RCLJND LUbEDUSE TAN~ FOR RERCSENE SPILL REMEPlATION EQUIPMENT SNED ~ ~ ~ ~ P~ 87.22' THIS ~ASOLINE SERVIDE STATION I1AS A NETWORK ~ ©ROUNPWATER MONITORIN~ WELLS INSTALL~ ON SITE THESE WELLS WILL SATISFy THE REQUIREMENT TO LOOATE A POWNSTR~M MONITORINS WELL. ROAD AF PROVAL STAMP DRI,WING TITLE SITE PLAN WITH NEW TANK L,~,YOUT DATE: I 07.14.09 I SCALE: I~'F=~o' DW6. NO. SP-1 UNDERGROU~ ALARM EQUIPMENT - LEAK DE' SPACE SENSORS AL~I~M @ANAL IN§TALb&TION ~IT fO~ LEN~ DETEC]ION SENSOR FOR PIPING RESERVED MANUFACTURER & MODEL NO, ITEM DESCRIP FiON MANUPAC?UR~R ~, MOUPI. NO I S~TORAGE TANKS PIPING, VALVES AND FITTINGS ONE-ST~P-Y O~NVENIP-NOE ST~P.: W/S~LES ~PPIOE 22' APl PRODUCT CODE FILL PORT LEGEND R M, SANTiNO, P,E NO, NYS 56025 HEATING & FUEL OIL NO 2GRADE DIESEL FUEL KEROSENE, DIESEL NO, 1 P'- 87.22' APPROVAL STAMP FULl, u~d,~i ~ U=PAFH'MENI Of H~LTH SERVIC~ BUReaU OF ~.WRON~ENT~L APPROVALTO CONCTRUCT SCDHS JOB NOH'~ 0 9 - I ? 5 E 1 These plans ano ~}~,~h~auon have been review~ and f~nd to be ir, cumpl[ae~ with Suffolk Coun~ Sani~ Code requirements bas~ submiff~ by the appli~nt. Thi~ appmvat expires on ~b? ~. OCT 0 ? ?nnq ~~, APPROV~ DATE R~ ENgiNEER DRAWING TITLE NEW TANK LAYOUT AND EQUIPMENT LIST IDATE: I 07.14.09 /scALE: I 1": 10' I LU J DWG. NO. A-1 _DE_ADHEN ANCHOR NOTE: REINFORCED CONCRETE DEADMEN TANK ANCHORS W/ STAINLESS STEEL HOED DOWN HARDWARE AND FIBERGLASS STRAPPING AB PROVIDED BY THE TANK HANU?ACTURER MAY NOT BE REQUIRED THE DEPTH TO GROUNDWATER WAS MEASURED TO BE 11"9' WHtCH AND WILL NOT INTERFERE WITH THE PROPER PLACEMENT OF THE TANKS. THE USE OF DEADHEN ANCHORS FOR THIS iNSTALLATION IS NOT ANTICIPATED AND THE DETAILS FOR THE ANCHORING IS PROVIDED ONLY ~F IT IS DETERMINED THAT ANCHORING IS NECESSARY. 12' 49' - 2" /*5' - 2" THE TANK MANUFACTURER (SEE DEADMEN ANCHOR NOTE) SPARE &' FITTING I (TYP 3 FOR THIS SUMP) NEW 8' THICK REINFORCED CONCRETE TANK MAT - I NOTE' REFER TO THE TANK LAYOUT ON DW6 A-I FOR SIZE OF NEW TANK MAT, THE CONCRETE TANK MAT WILL PLAN -15,000 SCALE: $/8" = !' Z" BIA SINGLE WALLED FPP VENT PIPE TO BE SLOPED BACK TO THE RED JACKET I I/Z HP SUBMERSIBLE GAL COMPARTMENTED TANK TANK AT 1/8" PER FOOT GRADE &Il FITTING W/ RISER PIPE TO CHECK TANK DEFLECTION AND LOCATED DN TANK CENTER LINE AND SET NO - 0" (SEE DW~ MFC FOR ALL TANK DIMENSIONS) TURBINE PUMPWITH LINE LEAK DETECTION NOTE I, THE NEW REINFORCED CONCRETE TANK HAT SHALL BE 3,5B0 PSI CONCRETE AT 2~ DAYS STRENGTH AND SHALL BE REINFORCED WITH #4 REBAR SPACED 12' O,C, BOTH WAYS ON NOTE 3: THE HIGH LEVEL ALARM SETTING FOR THE HAG PROBES HALL ON OWG H'I FOR ACTUAL EQUIPMENT LAYOUTS. 2" OTR TURN FULL PORT BALL VALVE STEEL PIPE UNION ~. D[A GALV STEEL RISER pIPE H ~M TEMFLEX (SEE NOTE 2) (SEE NOTE 8) ' z*" DIA DEFLE~CT]ON PORT TO BE INSTALLE~) IN A BUNG ON tHE CENTERLJNE OF THE TANK 49'-2" SC APPROVED 5 GAL FILL SPILL BUCKET MAINTAIN 2" MIN CLEARANCE BTWN ~ 8,000 GALS &" DIA BEH kB GALV STEEL RISER PIPE I~ HP SUBMERSIBLb TURBINE PUMP (TYP 2 F/ 15K TNK) PIPE F/MOTOR FUEL COMP-B 7,000 GALS PREMIUM UNLEADED [2" / FACTORYINSTALLEBIMPACT PLATES BENEATH ALL TANK OPENINGS MAINTAIN b" MINIMUM CLEARANCE ABOVE TANK BOTTOM 45' - 2" ELEVATION - 15,000 GAL COMPARTMENTED TANK SCALE: 518" = I' - 0" (SEE DWG MFC FOR ALL TANK DIMENSIONS) MAGNETORESTRICTIVE pROBE FOR LIQUID LEVEL INDICATION AND HIGH LEVEL ALARM (SEE NOTE 3) MAINTAIN 6' MINIMUM CLEARANCE ABOVE TANK BOTTOM J8I' l"Ifl IhFT AN" IS llll' RII![pON!HIIII I fY nP fIIF ]r~N~ IM~TPII 5flPll raHllt^qql4 TANK BED EXCAVATION DETAIL NOT TO SCALE WEATHERPROOF JUNCTION BOX WITH ~tM NPTTHREADS EY SEAL EPOXY AS PER NFPAAND NATIONAL ELECTRIC CODE SPECIFICATION NEW 15,OOO GALLON COMPARTMENTED DW FRP TANK THE TANK SHA[LL CARRY THE 12" MIN PEA GRAVEL BEDDING FOR TANK GW II'-g' BLS~ , SENSOR SWITCH MUST ~EACH BOTTOM OF TANK FIBERGLASS TANK WITH DRy ANNULAR SPACE BEEINSET TO RIGHT INTERSTITIAL TANK SENSOR F1 DRY ANNULAR SPACE M SANTINO, P E, LIE, NO NYS 58025 APPROVA STAHP t% I"l UL~ L, UUNTY DEPARTMENT OF HEALTH SERVI{~.~ ' BUREAU OF ENVIRONMENTAL ENGINEERING ' APPROVAL TO CONSTRUCT SCDHS JOB NO These plans and specification hav~ been reviewed and found to be m cumptiance witl~ Suffolk County Sanitary Code requirements based upon info,q'nafion submitted by the..a, pjolicant, This al ,prova{ to constn~ct expires on I.~JJ _ Expiration OCT 0?Z00 ' ' DRAWING TITLE DETAILS-15K CO PAR - ENTED TANK DWG. NO. T-1 ALL LEA~ DETECTION ~NS~S WITHIN PIPIN~ ~ ~AL Itl AECO~CE WITH THE H~UFACT~ER'3 INSTR~TtONS. FILL §PILL I]UHI[[T At4B TH[ BOTTOt4 OF THL M~%HBLE EOgEH. GW II'-g" BLS &9'-2" 4" DIA COAXIAL FILL DROP TUBE W/ AUTO FLOAT SHUT-OFF VALVE ,,f: 8,, 44'-6~" ~XCAVATION WITH FILTER FABRIC TOHOLD TRE PEA GRAVELIN PLACE NEW 15,000 GALLON DW FPP UNDERGROUND MOTOR FUEL ELEVATION 15,000 GAL DW FRP TANK SCALE: 5/8" = I' - 0" (SEE DWS NFC FOr? ALL TANK DINENSIONL MAINTAIN 6" MJN CLEABANCE ABOVE TANK BOTTOM FACTORYINSTALLEDIMPACT PLATES UNDER ALL TANK OPENINBS 6W 49'-2" I ~' ' ?.'~L ~"4'. ~ ,m u. ( O Z ~O O~ ~(z ~O~ APPROVAL STAMP ~ c ,. , ..... ~" ~ ~ DEPARTMENT OF H~TH SERV~ BUREAU OF ENVIRONMENT~ ENGiNFFRi~ These plans and specifl~t~on have been re~w~ - ~ z I and ~nd to be in ~mplian~ w~ Su~ ~n~ ~ ~ ~ Sanita~ C~e requiremen~ ~ u~ ~ z o ~ submi~ed by the ~i~ ~h~ap~v~ ~ ~ ~ ~ ~ DRAWING TITLE DWG. NO. DETAILS - 15K DW FRP TANK T-2 DEADNEN ANCHOR NOTE: REINFORCED CONCRETE DEAQMEN TANK ANCHORS W/ STAINLESS STEEL HOLD DOWN HARDWARE AND FIBERGLASS STRAPP~NB AS PROVIDED BY THE TANK HANUFACTURER MAY NOT BE REQUIRED. THE DEPTH TO GROUNDWATER WAS MEASURED TO BE II'-g~ AND WILL MBT INTERFERE WITH THE PROPER pLACEHENT OF TEE TANKS. MORE THAN 12" BELOW THE COVER FITTING FOR INTERSTITIAL I i ; T 44 -62 SPARE ~" DIA FITTING (TYP ~ FOR THIS SUMP) ,J , - I I SPARE A"FITTING I PLAN - 15,000 GAL DW FRP TANK SCALE: 518" : I' - 0" (SEE Ol41g ~"IFC FOR ALL TANK DIMENS/ONS) 12' FLEXIBLE ENTRY pITTING FOR OUTLINE OF AB' DIA FIERELITE MANWAY COVER FRAME ~:JN:b' fflP DggL~L~ WALLED (SEE NOTE ~)~ THREADED X SELL FLEX CONNECTOR -- SPARE A' MANWAY FITTING (TYP B) TANK FLEXIBLE ENTRY FiTTiNG FOR ELECTRICAL CONDUIT I~ HP SUBMERBIBLE TURBINE PUMP WI LiNE LEAK OETECTIO FIBRELITE SUPPORT FRAME W/ PLATFORM INSERT AND PLATFORM HANGER CUPS (TYP 6 CLIPS) NOTE I: TI:IE L'~AK DETECT~ON SENSOR ELEMENT SHALL BE SET NO MORE THAN I/2" ABOVE THE BUMP BOTTOM, THE SENSOR ELEMENT SHALL BE SECURELY MOUNTED THE HIGH LEVEL ALARM SHALL BE SET AT 90% OF SACK TO THE TANK WITH A MIN liB' PEN FOOT GRADE NP STP WI LEAK DETECTION FOAM BLOCK AS (TYP ALL PIPING SUMPS) AE" DIA FIBERGLASS TURBIK ENCLOSURE (PIPING SUMP) BO' STEEL ELL (TYP B) ELK STL FOR DIESEL GALV STL FOR GASOLINE MOUNTING COLLAR FOF TURBINE ENCLOSURE Z' QTR TURN FULL-- PORT BALL VALVE MAGNETORESTRICTIVE CABLE AND FLOAT FOR LIQUID LEVEL INDICATION ~ AND OVERFILL ALARM BETTING NOTE: MAG-PROBE HIGH LEVEL ALARM TO BE SET AT go% NOMINAL CAPACITY OF THE TANK. FACTORYINBTALLED IMPACT PLATES~ TANK TOP OPENINGS TO pROTECT TANK SHELL TANK SHELL TANK DIAMETER MANHOLE COVER AND FRAME ABS'Y W/MESH SAFETY PLATFORM AND 12" SKIRT FIBRELITE MOS. NO. FLAK - COVER AND FRAME FIBRELITE MOD. NO, FLSP/AE - SAFETY pLATFORM FIBRELITE MOD. NO. FLAE/BKIE " IE' DEEP FPP SKIRT HICK REINFORCED CONCRETE TANK MAT W/ #A REBAR 12" O C. BOTH WAYS ON TOP AND BOTTOM CONCRETE TO SLOPE AWAY FROM MANWAY FRAMES 12' SIDE SKIRT ~-~iNTTs: AIM MIN S" CLEARANCE BETWEEN SIDE SKIRT AND SIDE OF pIPING SUMP 2"IN 3' DOUBLE WALLED FPP PRODUCT pIPiNG FOR GASOLINE LEXIBLE ENTRY BOOT FOR 3" FRP pIPING TEST BOOT TO BE FULLED BACK AFTER TEST B" DIA THRD~g X BELL FRP TO STEEL ADAPTER DIA FLEX CONNECTOR NOTE: ~INTAIN APPROPRIATE EQUipMENT MANUFACTURER'S MINIMUM CLEARANCES WHEN INSTALLING THE SUBMERSIBLE TURBINE PUMP. KEEP PUHP BODY AT LEAST 6" OFF OF TANK BOTTOM, TYPICAL CROSS SECTION FOR SUB PUMP PIPING SUMPS NOT TO SCALE BALL CHECK VALVE W/EX IHALI UH -- TEE FOR VAPOR RECOVERY PIPING EXPLOSION PROOF J-BOX WIEY SEAL AS PER NEC F, LEAK DETECTION SENSOR (SEE NOTE I) FLEXIBLE ENTRY FiTTiNG FOR ELECTRICAL CONDUI1 A" DIA DROP TUBE FiLL PiPE WIfH UTOMATJC SHUT-OFF FLOAT VALVE ---- ~_ TANK CENTER LINE B" DIA SLEEP TO CHECK TANK 9EFLECTION AT TANK CNTR LiNE (SEE NOTE A BELOW) OUTSIDE COLLAR OF MANWAY COVER AND FRAME ASSEHELY FIBRELITE SUPPORT FRAME W/ PLATFORM INSERT AND PLATFORM HANGER CLIPS (TYP b CLIPS) NOTE 2, ~E M~SH PLATFORM SHALL BE CUT SO THAT THE 2" THREADED X BELL FIBERGLASS ADAPTER :LEXIBLE ENTRY FITTING FOR 2" FPP PIPE  PIPING SUMP W/ /~" Fill FOR 7K GASOLINE SCALE: 3/A=['-0" A" CIA STEEL RISER PIPE FOR VAPOR RECOVERY EXTRACTOR TEE AND BALL VALVE A" DIA RISER FOR TANK DEFLECTION READINGS (SEE NOTE I) FOAM BLOCKS AE" DIA TURBINE ENCLOSURE (SEE NOTE 5) EXPLOSION PROOF J~BOX AND EY SEAL AS PER NEC L" DIA FILL PORT CAP FITTING (SEE NOTE 5) AZ" CIA MANHOLE COVER AND FRAME ASS'Y W/SAFETY PLATFORM F[BRELITE FLAB W/ FLSP~2 PLATFORM I" HIN CLEARANCE (SEE NOTE 2) PITCH CONCRETE TANK MAT AWAY FROM MH COVERS AT A MJN GRADE OF 1/8" PER FT SIDE SKIRT NOTE~ UNTAIN MIN 2' CLEARANCE BETWEEN SIDE SKIRT AND SIDE OF pIPING SUMP 5 GAL FILL SPILL CONTAINMENT BUCKET FAIRFIELD INDUSTRIES~[NC MOD. NO. SC-5 OlA RISER PIPE SCH A0 GALV STEEL FOR GASOLINE SCH A0 SLACK STEEL FOR $1ESEL VEEDER ROOT PLPING SUMP LEAK DETECTION SENSOR (SEE NOTE A) 2' BIA SW FRP BENT PIPE (PIPE PACES OUT) BALL CHECK SALVE W/EXTRACTOR TEE FOR VAPOR RECOVERY pIPING (GASOLINE TANKS ONLY) A" DIA COAX DROP TUBE W/ AUTO SHUT-OFF OVERFILL PREVENTION FLOAT OPW MOD. NO. 6[SOC,-A001 MAINTAIN 6" MIN ABOVE TANK BOTTOM FACTORYINSTALLEO LMPACT PLATE BENEATH ALL TANK OPENINGS ) 6" MIN EXPLOSION PROOF J-BOX FOR LEAK DETECTION SENSOR PNOBE (SEE NOTE I) ~ FLEXIBLE ENTRY FITTING FOR ELECTRICAL CONDUIT TANK CENTER LLNE B" DIA DEFLECTION PORT TO BE INSTALLED IN A BUNG ON THE CENTERLINE OF THE TANK (SEE NOTE h) SPARE h" MANWAY FLTTiNG NOTEI' THE AT DIA DEFLECTION PORT SHALL BE INSTALLED IN A BUND ON THE CENTERLINE OF THE TANK THE PORT CAP CAN BE NO MORE THAN 12" BENEATH THE MANHOLE COVER NOTE 2: ~-AINTAIN A MINIMUM I" SEPARATION BETWEEN THE TOP RiM OF THE FILL SPILL BUCKET AND THE UNDER SIDE OF THE MANHOLE COVER BgTE B.. TRE TOP EOGE OF THE PIPNG SUMP SHALL TSRMINATE AT A pOiNT THAT iS H~GHER THAN THE MANWAY SKIRT AND SHALL MAINTAIN A MIN OF B" CLEARANCE BETWEEN THE MANWAY SKIRT AND THE COLLAR OF THE PIPING SUMP THE MANWAY SKIRT SHALL BE A MINIMUM OF A"IN DIAMETER LARGER THAN THAT OF THE pIPING SUMP COLLAR. NO~T~ A. ALL LEAK DETECTION SENSORS WITHIN piPING SUMPS SHALL BE SECURELY FASTENED IN pLACE AND SHALL BE INSTALLED IN ACCORDANCE WITH HANUFACTURER'E INSTRUCTIONS. THE LEAD WIRE FOR THE SENSOR ELEMENT SRALL NOT SE WRAPPED AROUND ANY PIPING OR CONDUIT WITHIN THE SUHP. ALL pIPiNG SUMP SENSORS SHALL BE LIQUID DISTINGUISHING, NOTE 5: THE FIlL PORT CAP SHALL NOT BE ANY LOWER THAN g" BENEATH THE MANHOLE COVER, THIS WILL ALLOW ACCESS TO THE FILL PORT AND INSURE A SAFE AND EFFICIENT DELIVERY OF MOTOR FUEL. TYPICAL CROSS SECTION FILL PIPING SUMPS FOR N~T TO SCALE INSIDE THE PIPING SUMP, SPARL I," MANWAY HI TING (TYP 2 THIS PIPING SUMP) AZ" O.D. TURBINE ENCLOSURE WiTH MOUNTING COL~R 5 GAL SPILL CONTAINMENT BUCKET WI INTERNAL BRAIN FAIRFIELD INDUSTRIES. INC MODEL NO. SC-5 (SEE NOTE kREINFORCING FLANGE FIBRELITE pROD, NO: FSLP/FLANGE-IA (SEE NOTE 5) FIBREUTE SUPPORT FRAME W/ PLATFORM INSERT AND PLATFORH HAN6ER CLIPS (TYP § CLIPS) FLEKIBLE EN'IRY BOOI PI 5" DIA SW FRP PIPING THE 2=DIA VENT AND 3" BIA VAPOR RECOVER piPING SHALL BE SLOPED BACK TO THE'rANK WllH A MIN dB"PER FOOT GRADE THE POHT CAP CAN BE NO MORE THAN 12" BENEAIH THE MANHOLE COVER. TO ALLOW ACCESS TO THE FILL PORT AND SPILL BUCKbl / C PIPIIqG SUHP W/ b," FILL I-OR 8K DIESEL SPAREB"MANWAY FITTING (TYP 2) A" OlA RISER TO CHECK TANK DEFLECTION AT TANK CNTR LINE (SEE NOTE B BELOW) EXPLOSION PROOF J-BOX FOR LEAK DETECTION SENSOR PROBE THREADED X BELL FRP TO STEEL ADAPTER FLEXIBLE ENTRY FITTLNG FOR 5" FRP PIPE NOTE h ~HE L~AK DETECTION SENSOR ELEMENT SHALL BE SET NO MORE THAN 112' ABOVE THE SUHP BOTTOM THE SENSOR ELEMENT SHALL BE SECURELY MOUNTED INSIDE THE pIPiNG SUMP. NOTE B. ~E MESH PLATFORM SHALL BE CUT SO THAT THE FILL SPILL BUCKET CAN EXTEND ABOVE THE PLATFORM AND PROVLDE UNOBSTRUCTED ACCESS TO THE Fill PORT ( PIPING SCALE HSD JACKEI I~ HP SUBMERSIBLE IUBBINE PUMP WI LEAK DB[ECIION UUIUI[}I C011 AN 0I: MANWAY SPARE A" MANWAY FITTING (TYP 2) TANK CENTER LLNE &2" O,D. TURBINE ENCLOSL R TURN BALL VALVE EXPLOSION PROOF J-BOX FOR -- LEAK DETECTION SENSOR PROBE (SEE NOTE I BELOW) FLEXIBLE ENTRY FITTING FOR ELECTRICAL CONDUIT FIERELITE SUPPORT FRAME AND PLATFORM INSERT 2" DIA FLEX C TEST BOOT FOR DOUBLE WALLED PIPING TO BE PULLED BACK EXPOSING THE END OF THE CONTAINMENT PLPE AFTER AIR TEST OIA RISER FOR MAGNETORESTRICTIVE PROBE FOR LIOULD LEVELINDIGATION AND OVERFILL ALARM SETTINGS (SEE NOTE 2 BELOW) FLEXIBLE ENTRY FITTING FOR B" DIA PIPLNG NOTE I, THE L~AK DETECTION SENSOR ELEMENT SHALL BE SET NO MORE THAN I /2" ABOVE THE SUMP BOTTOM, THE SENSOR ELEHENT SHALL BE EECURSLY MOUNTED INSIDE THE piPING SUMP. PETROLEU (SEE NOTE DOUBLE WALLED PRODUCT PIPING B) RP PIPING SHALL BE SLOPED BACK IA HIM 1/8"PENI:OOT GRADE PIPING SUMP W/ SUB PUMP FOR 15K GAS( S~ALE 3lA": I'- 0" 5 GAL SPILL CONTAINMENT BUCKET WI INTERNAL DRAIN FAIRFIELD INDUSTR[ES~ FIBRELITE SLPPORT FRAME AND PLATFORM LNSERT WI HANGER CLIPS (TYP 6 CUPS) -- BALL CHECK VALVE W/EXTRACTOR TEE FOR VAPOR RECOVERY PIEING 3" DIA SINGLE WALLED FR? VAPOR RECOVERY pipiNG (SEE NOTE 3) NOTE 5: THE B~DIA VENT AND B' VAPOR RECOVERY PIPING SHALL BE SLOPED BACK TO THE TANK WLTH A MIN lib"' PER FOOT GRADE .INE SUMP W/ /+" COAX FILL F/lEK GASOLINE APPROVAL STAMP '~ ~ FOLF, ,..,OU NTY DEPAR [MEN'[ OF H~ALTH SERVI~ BUREAU OF ENVIRO ~ENTAL ENGINeEriNG AppROVALTOCONS~RU~TSCDHSS~. ~, ~ These plans an¢ sp~dt,catio;n have been rev~w~ and ¢~n~ to be in con,plian~ with Surfak Cou~ Sani~ Code requirem~ts~ba~ u~n in~ation submiDeo by t~t, ~h~s s~mv~ ~ ~ expireson ~ ~1 '¢f[~]l~ , ~ Expiration Da~e ~ 0 7 2009 ' ApprOVAL DATE DRAW(NG TITLE PiPiNG SUMPS DWG. I I SHEAR VALVE W/ FLEX CONNECTOR FOR SUPER NO LEAD PRODUCT SHEAR VALVE W/ FLEX 77'::. L C'~''-~ BLENDER DISPENSER W/ NEW DISPENSER SUHP SCALE: 3/4" -- I' - 0" BE REPLACED (SEE NOTE 1½"DIA FLEX CONNECTOR LLLL[HEAI LuiJ[ILLllul~ ~, - -- SMITH FIBERCAST R~D THREAD IIA (SEE NOTE 4) FLEX ENTRY FITTING FOR JHP UbE DPW MODEL MATCHING W/EXISTING DISPENSER SIDE VIEW - MULTIPLE BLENDER DJSPENSER WITH NEW DISPeNSeR SUMPS~INS~ALLED SCALE: 3/~" =/' - 0 BRACKETS, CLAMP, ETC, UNIVERSAL SENSOR MOUNTING KIT JUNCTION BOX ANO Ey SEAL AS PER NEC ~ IL' GRC TO LIQUID DISCRIMINATING _EAK DETECTION SENSOR DETAIL- PROPER INSTALLATION OF DISPENSER SUMP SENSOR NOT TO SCALE U CONCRETE FO TING BUMPER °DETAIL APPROVAL STAHP , , ....... ., ~ BUREAU OF ENVIRONM~'A~_'~ nm~-/H SERVtCEt~ , ENGIN~_ APPROVAL TO CONSTRUCT These plans an~ spemfl~tmn ha~e and f~nd to be m compllan~ Sanita~ C~e r~uirements ba~ u In submi~ed by the --~,~ expires on ~ ~'~?~ap~al DRAWING TITLE DISPENSERS, PUMP ISLANDS AND DISPENSER SUHPS DWG. NO. M-2 NOTE !: THE EXISTING DISPENSERS MAY BE REPLACED IF THEY ARE DEEMED TO BE IN UNSATISFACTORY REPAIR TO CONTINUE INSERVICE. OTHERWISE, THE EXISTING DISPENSERS ARE TO REMAIN AND WILL BE REINSTALLED ON NEW DISPENSER SUHPS. ~XISTIN~ ISLAND FORHS SHALL BE REPLACED WITH INDIVIDUAL ~ X 5 DISPENSER ISLANDS AND PROTECTED BY U-BUMPERS ON EACH SIDE OF THE NEW DISPENSER ~ ///~ ~ // ~ NOTE 5: THERE IS ONLY ONE DEDICATED DIESEL FUEL DISPENSER. THE OTHER DISPENSERS ARE FOR GASOLINE ONLY, NOTE ~: A~L P~?DUCT PIPING TO BE INSTALLED S~ALL BE 2 -IN-3 DOUBLE WALLED FIBERGLASS PIP,NG AS HANUFACTURED BY SHITH FIBERCAST. NOTE 5: ~ =~' /~ / / ALL VAPOR RECOVERY AND VENT PiPINg TO BE INSTALLED SHALL BE EITHER 2" OR b" SINGLE WALLED FIBERGLASS NOTE 6: ~g~OU~D w~ .~ .~ TO ~ ~U,~O~ED ~ ~E*~. O~ ~~,. KINDORF CLAMPS SECURED TO TWO 2 DI~ STEEL PIPE SUPPORTS AND SHALL TERHINATE NO LESS THAN 12 ABOVE GRADE. ~UPPRESION SYSTEMS SHALL BE DESIGNED AND INSTALLED BY OTHERS AND IS NOT PART OF THIS f DRAWING TITLE ~ ~ i PIPING LAYOUT , ~ ' _[ AND ~ PIPING DETAILS TANK INSTALLATION NOTES PROPER INSTALLATION OP A DOUBLE WALLED FIBERGLASS TANK rs CRITICAL, DOUBLE WALLED FIBERGLASS TANKS MUST BE INSTALLED BY A MANUFACTURER'S CERTIFIES TANK INSTALLER WHO HAS THE COMPETENCE, EQUIPMENT AND EBPBRIENCE fo SUCCESSFULLY COMPLETE A QUALITY INSTALLATION, 2, PROPER INSTALLATION OF EACH TANK IS BSSENTIAL TO ENSURE THE SASFEY OF ALL THE iNDIVIDUALS INVOLVED IN THS TANK IN§TALEATION, T0 PREVENT TANK DAMAGE AND OR FAILURE LEADINB TO PRODUCT LOSS AND SUBSEQUENT ENVIRONMENTAL DAMAGE AND TO VALIDATE THE TANK STRUCTURAL WARRATY FOR UNDERGROUND PETROLEUM STORAGE TANKS, WARRANTY ACTIVATION I. TO ACTIVATE THE TANK'S BO-YEAR STRUCTURAL WARRANTY FOR UNDERGROUND PETROLEUM STORAGE, THE PUBLISHED INSTALLATION INSTRUCTIONS MUST BE FOLLOWED, 2~ THE INSTALLATION CHECKLIST (CONTAINMENT SOLUTIONS LIST NO, [NST 6002) MUST BE PROPERLY COMPLETED, SIGNED BY THE INSTALLING CONTRACTOR'S REPRESENTATIVE AND THE TANK OWNER'S REPRESENTATIVE, S, THE iNSTALLATION CHECKLIST MUST BE RETAINED BY THE TANK OWNER AND/OR INSTALLING CONTRACTOR TO VALIDATE ANY FUTURE WARRANTY CLAIM, ~iANDLING AND FREPARATION THE TANK OWNER IS REPSONSIBLE FOR RIDDING, UNLOADING AND SECURING THE TANK, ALL FIBERGLASS TANKS MUST BE MECHANICALLY U NLOADED, THEY MAY NOT BE SELF-UNLOADED BY THE DELIVERY TRUCK DRIVER. TEMPORARY STORAGE OF THE TANKS AT THE JOB SITE REQUIRE THAT THE TANKS BE PLACED ON SMOOTH GROUND WITH NO PROTRUDING ROGKS OR HARD OBJECTS THAT MAY PUNCTURE OR DAMAGE THE TANK SHELL. A, THE TANKS MUST BE CHOCKED WITH SANDBAGS, S. TIE THE TANKS DOWN IN HIGH WING CONDITIONS TO PREVENT THE TANKS PROM SHIFTING DR OTHERWISE DAMAGED. B. WHEN THE TANK HUST SE ROLLED FOR AIR/SOAP TEST, ROLL ONLY ON SBIPPING PADS DR SMOOTH SURFACE AND ENSURE THE FITTINGS AND COLLARS DO NOT COME IN CONTACT WITH THE GROUND. 7, iN FREEZING CONDITIONS, PROTECT COLLARS FROM WATER ACCUMULATION. FREEZING WATER MAY CAUSE FREEZE DAMAGE. 8. USE ONLY LIFTING EQUIPMENT TO MOVE TANKS. LIFT TANK USING ALL LIFT LUGS PROVIDED ON THE TANK. NO SHORTCUTS SHOULD BB TAKEN. g. OD NOT USE CHAINS OR CABLES AROUND TANKS AS THIS COULD DAMAGE THE SHELL EXTERIOR. BED AND BACKFILL I, THE USE OF APPROVED BACKFILL MATERIAL IS CRITICAL TO LONG TERM TANK PERFORMANCE. FAILURE TO USE APPROVED BACKFILL MAY RESULT IN TANK DAMAGE. B. REPLACE ALL EXCAVATED NATIVE SOIL WITH APPROVED BACKFILL OF PROPER SIZE AND GRADATION. USE BACKFILL WHICH MEETS ASTM C-S5 FOR QUALITY AND SOUNDNESS. B. REQUIRE THAT BACKFILL SUPPLIER CERTIFY THAT THE BACKFILL MATERIAL MEETS THIS SPECIFICATION, A. KEEP BACKFILL DRY AND FREE OF ICE IN FREEZING CONDITIONS. USE ONLY PEA GRAVEL OR CRUSHED STONE. 6, PEA GRAVEL MUST CONSIST OF CLEAN, NATURALLY-ROUNDED AGGREGATE WITH A MIX OF PARTICLE SIZES OF NOT LESS THAN I/6' OR MORE THAN 5lA" iN DIAMETER. 7. FOR PEA GRAVEL, NO MORE THAN 5% MAY PASS THE #2 SIEVE AND DRY GRAVEL DENSITY MUST BE A MINIMUM OF B5 LBS/FT~, B, CRUSHED STONE OR CRUSHED GRAVEL MUST BE WASHED WITH ANGULAR PARTICLE SIZE NOT LESS THAN 1/2" OR MORE THAN 10. FOR CRUSHED STONE OR CRUSHED GRAVEL, NO MORE THAN 5% MAY PASS THE #8 SIEVE AND DRY GRAVEL DENSITY MUST BE A MINIMUM OF BB LSD/PT~. IL DO NOT MIX APPROVED BACKFILL WITH SAND OR NATIVE SOIL OR BACKFILL TANKS WiTH SAND OR NATIVE SOIL E. PRE-INSTALLATION TESTING IMPORTANTI O0 NOT PRESSURIZE TANKS OVER 5 PSIG SINCE TANK DAMAGE DR PHYSICAL INJURY CAN RESULT B. A VISUAL AIR/SOAP TEST IS TO BE PERFORMED ON ALL TANKS PRIOR TO INSTALLATION B. WARM WEATHER SOAP SOLUTION - B GALONS OF WATER WITH 2 OUNCES OF HOUSEHOLD DISHWASHING DETERCENT FREEZING CONDITIONS SOAP SOLUTION - SUBSTITUTE I GALLON DF AUTOMOTIVE WINDSHIELD WASHES SOLUTION FOR I GALLON OF WATER. B, COVER ENTIRE TANK OUTER SURFACE WITH SOAP SOLLUTION (EXCEPT DOUBLE WALLED TANKS WiTH LIQUID FILLED SPACE). COVER FITTINGS WITH SOAP SOLUTION AND CAREFULLY INSPECT FOR LEAKS AS INDICATED BY THE FORMATION OF BUBBLES. S. SOAP TEST SHALL BE WITNESSED BY A REPRESENTATIVE OF THE SUPFOLK COUNTY DEPARTMENT OF HEALTH SERVICES F. SiZE OF TANK EXCAVATION L TANKS THAT HAVE ARE A' TO 10' IN DIAMETER REQUIRE THAT A MINIMUM OF ]8" OR PREFERRABLB SA" SPACING BE MAINTAINED BETWEEN ADJACENT TANKS ANO BETWEEN THE SIDE WALLS AND END WALLS OF THE EXCAVATION. 2~ IF S' DIA TANKS ARE TO BE ANCHORED, A MINIMUM CLEARANCE OF 2A' BETWEEN TANKS IS REQUIRED. IN THE CASE OF TANKS, A MINIMUM OF B' MAY BE NECESSARY TO ACCOMDDATB THE WIDER REINFORCED DSADMEN ANCHORS. ;5, UNgERWRITERS LABORATORY (UL) SPECIFIES THAT THE DEPTH OF COVER OVER A FIBERGLASS TANK CANNOT EXCEED 7 FT A. EXCAVATION MUST SE DEEP ENOUGH TO ALLOW THE TANKS TO BE BEDDED WITH A HINIMUM OF lb' OF PEA GRAVEL OR FOR TANKS INSTALLED AFTER 1986 THE TANK MUST SEAR A PERMANENT STENCIL, LABEL OR PLATE CONTAINING THE FOLLOWING INFORMATION: I. MANUFACTURER'S STATEMENT THAT, "THIS TANK CONFORMS WITH B NYCRR PART B, THE STANDARD OF DssrGN BY WHICH THE TANK WA~ MANUFACTURED. THE PETROLEUM PRODUCTS AND PERCENTAGES OF VOLUME OF PETROLEUM ADDITIVES WHICH MAY BE STORED PERMANENTLY AND COMPATIBLY WITHIN THE TANK OR REFERENCE TO A LIST AVAILASLE FROM THE MANUFACTURER WHICH INDENTIFIES PRODUCTS COMPATIBLE WITH ALL TANK MATERIALS, A. THE YEAR IN WHICH THE TANK WAS MANUFACTURED. A UNIQUE IDENTIFICATION NUMBER, §, THE DIMENSIONS, DESIGN AND WORKING CAPACITY AND MODEL NUMBER OF THE TANK, 7. THE NAME OF THE TANK MANUFACTURER OR FABRICATOR, A SECOND LAGEL WHICH SHOWS ALL THE INFORMATION REQUIRED ABOVE AND WHICH ALSO SHOWS THE DATE DF INSTALLATION MUST SE CONSPICUOUSLY DISPLAYED AND PERMANENTLY AFFIXED AT THE FILL PORT, IT MUST BE READILY VISIBLE TO THE CARRIER AND MAY SE IMBEDDED IN CONCRETE, WELDED TO THE FILL PORT OR OTHERWISE PERMANENTLY AFFIXED, PIPING AND DISPENSER SUHP NOTES A, GENERAL E THE'TURBINE ENCLOSURE (PIPING SUMP) PROVIDES A HOUSING FOR A SUBMERSIBLE PUMP, TERMINATION POINT FOR DOUBLE WALLED PIPING AND AN ACCESS TO FITTINGS OR ACCESSORIES ON THE TANK TOP, E, THE TURBINE ENCLOSURE IS CONSTRUCTED OF FIBERGLASS REINFORCED PLASTIC (FRP), A PROVEN MATERIAL FOE LONG-TERM PERFORMANCE. THE RIGID FRP CONSTRUCTION DOES NOT DEFORM DURING OR AFTER INSTALLATION 5, THE TURBINE ENCLOSURE IS SUPPLIED WITH NON-SEALED, WATERTIGHT OR SEALED PRE TOPS, A, THE WATER]GHT TURBuqE ENCLOSURE INCLUDES A PUSH-ON LID WITH O-RING SEAL AND PROVIDES A WATERTIGHT SEAL WITH THE WATER LEVEL A MAXIMUM OF 12" ABOVE THE TOP OF THE LID, 5,THE,SEALED TURBINE ENCLOSURE INCLUDES IA NUTS AND BOLTS WITH A FLAT GASKET AND IS WATERTIGHT WITH THE WATER LEVEL TO A MAXIMUM OF 7' ABOV~ THE TOP OF THE LiD, S, THE TURBINE ENCLOSURE MUST BE MOUNTED TO A SECONDARY CONTAINMENT COLLAR ON THE TANK TOP 7, IN THE EVENT OF AN ACCIDENTAL SPILL OR LEAK FROM THE PRIMARY PIPING, THE SPILLED PRODUCT WILL DRAIN THROUGH THE SECONDARY OR CONTAINMENT PIPE TO THE TURBINE ENCLOSURE AND ACCUMULATE IN THE SECONDARY CONTAINMENT COLLAR AND ,TURB NE ENCLOSURE, THE LEAK DETECTION PROBE INSTALLED IN THE TURBINE ENCLOSURE WILL DETECT THE SPILLED PRODUCT AND TRANSMIT AN ELEETRICAL SIGNAL BACK TO THE ALARM CONTROL PANEl THAT SOUNDS AN AUDIBLE AND VLSUAL WARNING SIGNAL B, WHILE THE TURBINE ENCLOSURE HAY GE MOUN IED TO THE SECONDARY CONIAINMENI COLLAR Wl IHOUF ADHESIVE, AN ADHESIVE KIT IS SUPPLIED WiTH EACH TURBINE ENCLOSURE TO ATTACH IT TO THE SECONDAA~Y CONTAINMENT COLLAR AT THE JOBSITE, SEALING THE COLLAR/TURBINE ENCLOSURE SEAM PREVENTS THE INGRESS OR EGRESS OF WATER OR FUEL FROM THE TURBINE OR PIPING SUMP ffNCLOSURE, B,THE TURBI,NE ENCLOSURE/PIPING SUMP SHALL BE SEALED TO THE CONTAINMENT COLLAR BY MEANS OF AN ADHESIVE KiT SUPPLLED BY'THE. TANK MANUFACTURER. B. FRP WATERTIGHT TURBINE (PIPING SUM~) ENCLOSURE - MODEL WTEAE I. THE WATERTIGHT TURBINE ENCLOSURE INCLUDES AN ERP ENCLOSURE BODY WITH AN ADHSIVB CHANNEL AT THE TOP FOR A FIELD'JOINT, AN FPP REDUCER WiTH O-RING GROOVE AND O-I~INS GASKET AND A PUSH-ON FRP LID WITH TWO HANDLES . B. THE TURBINE ENCLOSURE BODY IS AB' IN DIAMETER AND A MINIMUM OF TWO FEET IN LENGTH. THE TOP OF THE ENCLOSURE BODY HAS AN ADHSIVE CHANNEL TO ALLOW FOR A FIELD SEALED WATERTIGHT dOINT TO THE REDUCER. TO ACCOMODATE DEEPER BUR AL DEPTHS, LONGER ENCLOSURE BODIES ARE AFAILASLE [N ONE FOOT INCREMENTS. S, AFTER SEALING THE ENCLOSURE BODY TO THE COLLAR AND COMPLETING ALL PIPING AND ELECTRICAL GONNECTIONS~ THE REDUCER AND LID ARE PLACED OVER THE ENCLOSURE BODY, THE AE" X BO" ID OR AS" × REDUCER FITS ONTO THE MATCHING AR" DIAMETER ENCLOSURE BODY. THE BOTTOM OF THE REDUCER FITS iNTO THE ENCLOSURE BODY ADHESIVE-CHANNEL END. THE REDUCER iS THEN FIELD SEALED TO THE ENCLOSURE BODY USING THE SUPPLIED ADHESIVE KIT, THE REDUCER/ENCLOSURE SOUS JOINT ES ON THE EXTERIOR OF THE ENCLSOURE BODY ALLOWING EASY FIELD iNSTALLATION OF THE ADHESIVE WITHOUT ENTERING THE ENCLOSURE, THE TOP OF THE REDUCER (50" ID) INCLUDES A GROOVE WITH A LUBRICATES SPECIALLY FORMULATED GUNA N O-RING, WHEN THE LID IS PUSHED OVER THE O-RING, THE LID FLANGE COMPRESSES THE GASKET PROVIDING A WATERTIGHT SEAL WITH WATER LEVEL IE" ABOVE THE TOP OF THE LID, 5.THE O-RING LUBRICANT WILL REQUIRE PERIODIC REPLACEMENT AS IT WILL DEGRADE OVER TIME. ANY LUBRICANT THAT WILL NOT DISSOLVE IN GASOLINE OR WATER NOR ATTACK BUNA N RUBBER IS ACCEPTABLE, THE WATERTIGHT TURBINE ENCLOSURE (PIPING SUMP) MUST BE VENTED AT ALL TIMES, WHILE THIS IS USUALLY AOGOMPLIBHBD BY MEANS OF THE SECONDARY PIPE IN A DOUBLE WALLED PIPING INSTALLATION, iT iS THEREFORE MPERAT VE THAT THE TEST SOO~' ON,THE DOUBLE WALLED PIP~NG SE PULLED BACK AWAY FROM THE SECONDARY PIPE, IFiT~HE BOOT IS LEFT IN PLACE AFTER TESTING THE SECONDARY PIPING SYSTEM, THE WATERTIGHT TURBINE E~CLOSURE (PIPING SUMP) WILL BE UNVBNTE0. IF NO LID IS USED AS IN THE CASE OF THE TURBINE ENCLOSURE WITH THE F LL E EEl.5 GALLON SP L~ BUCKET, CpMB NATION, TH~SUMP CAN BE CONSIDERED VENTED. OTHER PIPING SUM.PS MAY NOT BE ADEQUATELY VENTED IF THE LID JS IN PLACE AND THE TEST BOOT IS NOT PULLED BACK. C, FRP NON-SEALED TURBINE ENCLOSURE - MODELS NTEAE THE NON-SEALED FRP TURBINE ENCLOSURE rNCLUDES AN FPP ENCLOSURE SODS, AN FRP REDUCER AND A LOOSE FIT FRP LID WiTH HANDLE, S THE TRUBINE ENCLOSURE BODY IS AB" ~N DIAMETER A~D A MINIMUM OF B' IN HEIGHT. TO ACCOMODATE DEEPER BURIAL DEPTHS, LONGE'~ ENCLOSURE,BODIES ARE AVA,ILASLE IN ONE FOOT INCREMENTS THE ENCLOSURE SODS IS FIELD SEALED OT THE ~ANK COLLAR USING THE ~UPp[LIED ADHESIVE KIT B, AFTER BRAKING TEH ENCLOSURE BODV TO THE COLLAR AND COMPLETING ALL PIPING AND ELECTRICAL CONNECTIONS, ~HE P,:DUCER ENO LID ARE PLACED OVER THE ENCLOSURE BODY. THE AB" X BO" ID REDUCER EITS ONTO THE MATCHING ,*B O AM ~' ER END OSURE BODY, THE REDUCER BOTTOM FiTS LOOSELY OVER THE ENCLOSURE A. THE ENCLOSURE LID IS DE.5" OUTSIDE DIAMETER AN[} FITS LOOSELY OVER THE TOP OF THE REDUCER, THE B0" TOP OPENING ALLOWS POR THE REMOVAL OB A ~B" MANWA'Y LID (2S" ODD THRDUGIH THE OPENING. BOTH THE MANWAY LID AND THE tURBINE ENCLOSURE TOP CAN [BE REMOVED THROUGH A ES' MANHOLE AND COVER. D. ~ ~URS NE ENCLOSURE (P P N9 SU'IP) CAN BE,,~IL"ff AFTER THE TURBINE ENCLOSURE HAS'BEEN PLACED:tN'PE'?ROEEO~I PRODUCT SERVICE, NEVER ENTER A TURBINE ENCLOSURE WITHOUT PROPER TRAiNING,AND O.S,H,A APPROVED EQUIPMENT. B. THE USE Of MANWAYS IS NO'~IINTERDED TO ~NCOURAiSE TANK ENTRY, WHICH CAN POSE A SAFETY HAZARD FOR UNQUALIFIED MECHANICS ONCE PRODUCT HAS BEEN pLACED IN THE TANK. E. TESTING I. TEST ALL TURBINE ENCLOSURES (PIPING SUMPS) HYDF~OSTATICALLY WITH THE WAT R LEVEL ABOVE THAT OF THE PIPING NOTES A PRODUCT PIPING I. THE INSTALLATION AND PLACEMENT OF PIPING SHALL CONFORM WiTH NFPA #~0, 5OA, NYS DEC REGULATIONS, SCDHS INSTALLATION GUIDELINES AND GOOD INDUSTRY PRACTICE, 2, FIBERGLASS PIPING AND FITTINGS SHALL BE LISTED WITH UNDERWRITERS LABORATORY AND SHALL BE COMPATIBLE WITH THE CONCRETE NOTES - GENERAL Al I CONCRE I F WORK, BI-TAB S AND CONS TRUC lION MF1 HODS SHAt L CONFORM WITH THE PROVISIONS OF THE AMERICAN CONCRETE INSTITUTE (ADO, NEW YORK STATE (NYS) BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE CONSTRUCTION AND LOCAL BUILDING CODES AS APPLICABLE, FOR ALL CONCRETE SLABS ON GRADE THAT WiLL BE SUBMITTED TO VEHICULAR TRAFFIC LOADS AND HBO LOADS ARE TO BE POURED WITH A MIN OF 5,500 PSI CONCRETE AT SB DAY STRENGTH AND A MINIMUM OF 8' THICK AND REINFORCED WITH #A STEEL REBAR SPACED I~' ON CENTER AT THE TOP AND BOTTOM OF THE SLAB AND IN BETH DIRECTIONS, FOR ALL CONCRETE SLABS ON GRADE THAT WiLL NOT BE SUBJECT TO SUCH LOADING AS IN #B ABOVE, ARE TO BE POURED FROM A NIH OF 5,500 PSI CONCRETE AT 28 DAY STRENGTH WITH A MIN THICKNESS OF 8" AND REINFORCED WITH BXB/10-10 WELDED WIRE MESH, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF ~500 PSi AT 28 DAYS, REINFORCING STEEL SHALL BE A GOOD QUALITY GRADE A0 AS PER THE LATEST EDITION OF ASTM ASIS. SUB BABE MATERIAL FOR THE CONCRETE SLABS IS TO BE LEVEL AND COMPACTED, MECHANICAL COMPACTION WITH VIBRATING PAN COMPACTORS MA~ SE REQUIRED, TANK SLAB TO SLOPE A MINIMUM OF I/8" PER FOOT AWAY FROM GRADE ACCESS NANWAYS, APPROVAL STAMP :.,, ~ b~.r, *,.,~dr~ FY O£P~NTMt::QN~' OF HE. ALTH SERVtCE~ BUREAU OF ENVIRONMENTAL ENGINEE~NG0 ,'.,.PPROVAL TO CONSTRUCT SCDHS JOB NO, 9 these plans and specihcahon have been reviewed and found to be in compliance with Suffolk County Sanitary Code requirements based upon irffocmation sub.mitted by the applicant. This approval to consffuct -175 R1 OD, u / 2009 APPROVAL DATE DRAWING TITLE NOTES DWG. NO. N-1 42" CONTAINMENT COLLAR SHELL CODES: 2-E8DO7SD, 1-ESDO9SD. 1-OEDOSNE I U.im~ I I APPROVALI STAMP  .' , ~.-~....,.,u,, I ~ QEPARTIvlENT OF HEALTH SERVIC~ BUREAU OF ENVIRONMENTAL ENGINEFr~LNG APPROVAL TO CONSTRUCT 8COHSI jOB NO.~ M These plans and speQhcation havei been reviewed ,~¢~,~ ~ !~,~;~ and f°dhd t° be in c°mpliance with ~uffolk C°unty ~ ~' Sanitar~ Code requirements based lupon Infofmatlon ~ ,~.' ~ expires on ~ submitte~ by the applicant. Th.s apFn3val to constm~ , ~ r.,o ~ gOT o'?zoo9 ' ' .,_ DRAWING TITLE DWG. NO. MANUFACTURER'S TA'qK DRAWINGS MFC I sw ,~ (~2)~-; ~ ' 7 ¢- ' 7 ¢- ' r~' -hi WATERTIGHT TANK SUmP ANNULAR SPACE ~ 9 ¢COMP-A ] 12"x 12"x 16' DEADMAN 12"x 12"x 16' DEADBAN 12"x ,12"x 16' DEADMAN NOTES: [] HOLD DOWN STRAP CLIP ~ 4 HOLD DOWN STRAP LOCATION ~ ~PE "13" LrFT LUG - SD I ~PE "15" LIFT LUG - HO DWT-6 DWB-2 (8')-SM/TM ~4/25/08 MCINDO0 ASSOCIATES' R.MOEN 7,796/69,53 NTAINMENT ~E~: ~/~T ~G SOLUTIONS 7650/9450 1,18411 .DW6 22" FLGD. MANWAY w/&-4" NPT 42" CONTAINMENT COLLAR TYP.) SHELL CODES: 22-E8DO928, 1-08D1028 22" FLGD, MANWAY [] ENCLOSURE SPACE FTG _ ~ _ _ 1 ~ 3 4 5I 6~ 7' 8 ~ I0 1 -- 10" 10'L ~ 16-1/:2", ~P, ' 9'-7 1/2" ~ 3'23 115/16". -~'-5 ~/16" 9'-7 ~/2" 5'-10 5/8" ~'-6 ~/2" 12"x 12"x 16' DEADMAN 12"x 12"x 16' DEADMAN 12"x 12"x 16' DF. ADMAN NOTES: [] HOLD DOWN STRAP 6LIP · 41 HOLD DOWN STRAP LOCATION D ~PE "13" LIFT LUG - SD ~ TYPE "13" LIFT LUG - HD Product Code: # 8D15SD551 Active Date: 10/14/05 Order #:. Qty: City:. State:_ Delivery Dote: Rep:, DWT-6 TYPE I[ (8')-iSdO0 ~'~/8/o5 K,.A.SO£DER C~CONTAINHENT 14,545 SOLUTIONS 7500/9,t50 6748,DW6