33854-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEP~T~NT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34610 Date: 10/15/10 THIS C~KTIFIES that the building NEW DWELLING Location of Property: 1145 FLEETWOOD RD (HOUSE NO.) (STREET) County Tax ~ap No. 473889 Sectio~ 137 Block 4 Subdivision Filed Map No. Lot No. CUTCHOGUE Lot 26 (HAMLET) conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 28, 2008 pursuant to which Building Permit NO. 33854-Z dated APRIL 28, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH DECK, COVERED ENTRy AND SECOND FLOOR BALCONY AS APPLIED FOR. The certificate is issued to ALFRED A & MARy M MAGILL (OWNER) of the aforesaid building. SUFFOLK COUiTrY DEPART~NT OF HEALTH APPROVAL R10-03-0041 ~.Rt-rKICAL C~I('rIFICATE NO. 06- 3958 PL~4BERS CERTIFICATION DA'r~u~ 10/09/10 THOMAS TAGGART 12/30/09 03/26/10 Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUI~.nING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33854 Z Date APRIL 28, ~ Permission is hereby granted to: ALFRED A & MARY M MAGILL 700 GLEN COURT CUTCHOGUE,NY 11935 for : DEMO OF EXISTING SINGLE FAMILY DWELLING & CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 30304 at pr-m~ses located at 1145 FLEETWOOD RD County Tax Map No. 473889 Section 137 Block 0004 Lot No. 026 pursuant to application dated APRIL 28, 2008 and approved by the Building Inspector to expire on _ Fee $ 1,634.30 ' ature CUTCHOGUE ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30304 Z Date MAY 10, 2004 Permission is hereby granted to: ALFRED A & MARY M MAGILL 700 GLEN COURT CUTCHOGUE,NY 11935 for : DEMOLITION OF AN EXISTING SINGLE FAMILY DWELLING AND CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1145 FLEETWOOD RD County Tax Map No. 473889 Section 137 Block pursuant to application dated MAY 10, 2004 CUTCHOGUE 0004 Lot No. 026 and approved by the Building Inspector to expire on NOVEMBER Fee $ 1,634.30 10, 2005. ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY JAN 15 2010 BLDG. DEPT, TOWN OF SOUI'HOLD This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commemial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction:/t/~,/ Old or Pre-existing Building: LocationofProperty: //ff.,q'- ~-~---~.~--~ooZI ~7~. House No. Street Owner or Owners of Property: ,~-~'~ ~ ~'tr)~ t'~& Suffolk County Tax Map No 1000, Section 157 (check one) Hamlet Block Lot ~ G Subdivision Filed Map. Lot: Permit No. ~3 ~ ~"'~ Date of Permit. ,~7~tgtv' 2~ 2at}~Applicant: ~ ~--~~ Health Dept. Approval: ,~"~- $ o 2-~o 5 Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Final Certificate: (check one) Applicant Signature Electrical Inspectors, Inc. 308 East Meadow Avenue East Meadow, NY 11554 Office: (516) 794-0400 (631)396-7474 Fax: (516) 794-5854 Website: www.electficalinspectors.eom Emaih info~lectdcalinspectors.com Mail To: Michaels Electric Michael Ostrowski PO Box 419 West Islip, NY 11795 License#: 35472-ME Certificate Number: 06-3958 Municipality: Southold, Town Of Inspector: 125 Issue Date: 3/26/20107 pmpergt Address: I I Alfred Magfll ~.~ ~ 1145 Fleetwood ~ ~ Cutchogue,~,~ S~fion: 137 Block: 4 ~e 26 ~0~ ~ ~o~ ~o ~ ~ ~o~c~ w~ ~xo~ ~c co~ No vis~l defec~ we~ found for the elec~cal ins~ction h~in ~low only. ResMential Inspection/New Residence Basement: Storage Room lst Floor.. Bathroom. Deck 2nd Floor: Bathroom, 2 Bedrooms Attic: Storage Room I Car Garage 37- Duplex Receptacles, Transformer, 45- SWitches Incandescent Fixtures, 200Amp Singi Room, Office, Pantry Master Bedroom, Walk-In Closet 6- Smoke Detectors, 1- I- Dishwasher, 27- Recessed Fixtures, 2- Fluorescent Fixtures, 22- 1- Exhaust Fan, 2- 20Amp A/C Blowers, 1- CO Alarm. p Single Phase Main Panel/4OCkts/$1 Used. * Rough 7/18/06 Final 3/25/10 Richard M. Bivone President Philip F. Goehfing Chief Elec~cal Inspector Not valid unless signed by an 7/ffzed Eli Agent Town H~I, 53095 M~ Rosd P. O. Box1179 Southo~. New Yo~ ft971 Fax (516) 765-1823 Telephone (516) 765-t 802 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD CERTIFICATION DATEs Suilding Permit No.. 3~ (please print) contains less than 2/10 of I certify that the solder used in the water supply system 1% lead. - (Plumbers Sworn to before me this day of~ Notary Public, County ALICIA WALK[I{ ~ Public. State of New York No. 0 IWA6 ] 53064' Corn Qualifie~l. in S~ffolk County mi~oa t~xpires Sep[ 25, ~ ',,% 765-18O2 BUILDING DEPT. INSPECTION ~ FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] ROUGH PLBG. [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION DATE ~'/~"'~ ~ ~ ~' 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ~FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ~/ ~-- / ~ ~'~ m ~- DATE ~-~ ~-I '~ ~ -~- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOU.~DATION ~ [ ] INSULATION ~ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION . DATE ~ INSPECTOR ' / - ~' - ~ TOWN OF SOUTHOLD BUILDING DEPT. 765- t 802 INSPECTION [ ] FOUNDATION 1ST [~ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: INSPECTOR DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]ROUGH PLBG. [ ] FOUNDATION 2ND ,~!NSULATION, ~' [ ] FRAMING / STRAPPING~ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ~INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE __ INSPECTOR~ ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: /~'/'~/~'~ ~~/~ _~1~_ ~. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING ~FINAL ~ ~ [ ] FIREPLACE & CHIMNEY [ ] fiRE SAFETY INSPECTION [ ] RRERESlSTANTC0NS~ [ ] FIRERESlSTANTPBiETRATION REMARKS: DATE INSPECTOR CHARLES M. THDMAS, P-..A. PO Box ,IAMESPORT, NY I 194? May 6, 2009 Letter of Certification Al Magill Project Location: 1145 Fleetwood Road Cutchogue, NY 11935 Re: Main House I have inspected the above referenced project (Building Permit # 33854 Z) and have found the wood frame construction, and the required strapping to be in conformance with NYS building code. Please do not hesitate to contact me with any questions regarding this matter. BLDG. DEPT. .... TOWI~ OF SOUTHOtl) Sincerely, Charles M. Thomas TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined ,~ff0 ,20_4 Approved d I 0 ,20 ~ Disapproved a/c Expiration \ [ [ 0 , 20 '~ PERMIT NO. BUILDING PERMIT APPLICATION CHECKLISt[ Do you have or need the following, before applying? Board of Health 3 sets of Building Plans v Planning Board approval Survex ~' ~~ Check t/ Septic Form ~' N.Y.S.D.E.C. Trustees Contact: Mailto: ,~.f',,,~:} /$ 7oo ~tc-.,J ~a~-r ~ ) Phone: 6~/"?J~t-6.tStO APPLICATION FOR BUILDING PERMIT INSTRUCTIONS Date ,/~t/~ ' 6~ ,20 o ~t a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e,. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. , * f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or n"'ame, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises ,,gz~-~E-2:~ 6~ ,n,t,~,~. (As'on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section Subdivision /37 (Name) Block 9t Filed Map No. Lot ,, ~6 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building ~ Addition Repair Removal Demolition t/ Other Work 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars Z- Fee Alteration (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use~ 7. Dimensions of existing structures, if any: Front Height Number of Stodes Rear .Depth Dimensions of same structure with alterations or additions: Front Zo.~- Rear Depth. ~-~'. Height ~-o..~ Number of Stories ~._ 8. Dimensions of entire new construction: Front :~ $. ~' Rear Height ~ Number of Stories 7_- 9. Size of lot: Front qg. 7 Rear 8'~' ../ .Depth Depth ~'q. -~ 10. Date of Purchase 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES ,r NO 13. Will lot be re-graded? YES ~-' NO__Will excess fill be removed from premises? YES ¢'~ NO 14. NamesofOwnerofpremises~-f'w.~0 ~'/,,Z,~t~, Address 7~t~ 6'~t-..,/~/d.'t~- PhoneNo.~.g'/-?..~p'-&:/¢'~ Name of Architect ~'/,~.4 t:t::~ 77/o~-,.,¢S Address,W.~.z¢o.~, $'77 //~y:z Phone No ~-f/- 722- 7~.~ Name of Contractor Address,O-/~,~-~,o,~ ,~o~, Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES t,- * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES ~" NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. '~'~' STATE OF NEW YORK) SS: COUNTY OF .~o,~--fmO~tF_l ,/2~'/¢-.~ ,62 . M,~/~(._ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this ~..~q4x day of ,/~ff(~ 20tOq ~ N~t~bfic PENNY BEDELL 8o. 018116099317 New York State Department of Environmental Conservation Building 46 - SUNY, Stony Brook, New York 11790-2356 Telephone (631) 444-0365 Facsimile (631)444-0360 TIDAL WETLAND LETTER OF NON-~-dRISDICTION Erin M. Crotty Commissioner January 22, 2003 Mr. Alfred Andrew Magill 700 Glen Court Cutchogue, NY 11935 Re: UPA#i-4738-03073/00001 1145 Fleetwood Road Cutchogue SCTM#1000-137-4-26 Dear Mr. Magill: Based on the information you have submitted, the New York State Department of Environmental Conservation has determined that: The property landward of the "Top of Bank"/concrete wall at approximately elevation 24 NGVD, as shown on the survey prepared by Stanley J. Isaksen, Jr. last revised 7/29/2002, is beyond Article 25 (Tidal Wetland) jurisdiction. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act . Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. r~\'~eve you ?f Please be further advised that this letter does not. the responsibility of obtaining any necessary permi~ or approvals from other agencies, i ~~.n( ~/'/ncerel~ , · John Wieland LJS Permit Administrator cc:BMHP File Albert J. Krupski, President James King, Vice-President Artie Foster Ken Poliwoda Peggy A. Dickerson TO: FROM: DATE: RE: Town Hall 53095 Route 25 P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-1366 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Building Dept. Board of Trustees May 12, 2004 Alfred Magill 1145 Fleetwood Rd., Cutchogue SCTM#137-4-26 ' 122O04 The Southold Town Board of Trustees reviewed the survey prepared by Stanley J. Isaksen, Jr. last dated February 27, 2003 and determined the proposed new cesspool to be out of the Wetland jurisdiction under Chapter 97 of the Town Wetland Code and Chapter 37 of the Town Code. This is not a determination from any other agency. Board Of $outhold Town Trustees SOUTHOLD, NEW YORK PERMIT NO .................... ALFRED A MAGILL ISSUED TO ...................................................................................................................... Ant'hsrizali n the Sfe~ of New Y~ 1893; end ~pter ~ m ~e ~ m t~ Stere of New Yo~ 1952; and ~e ~o~ To~ ~dmance en- t~ ."R~U~TING AND ~E P~CING OF OBSTRUCTIONS IN AND ON TOWN WATERS AND PUBLIC ~DS ~ t~ R~OVAL OF SAND, G~VEL OR O~ER MATERIA~ FROM ~DS UNDER TOWN WA~RS;~:. end in ecco~ence wffh the Re~l~ion of The B6erd adopted et · meeting held on ..~.~ar~....?2 ~0~......~., end in consideration of the sum of $ ........ ~D~. 0~- ~id by A~d ..A....Magill Te~s end ~ndl*ions [Jded on *he reverie slde he.of, of So.hold To~n T~es a~horJzes and perm~ ~e [ollowin~: Wetland Permit to remove "oid:; ~.ouse/bioc~ /oundanon/ replace with poured concrete ioundation - new home on ~ame footprint with dryweHs, gutters and haybaie~. · l~ in eccorde~e wi*h the deSeXed sp~i~cafions as prec.*ed in IN WffNESS WHEREOF, ~e said ~rd of T~ees ~re- by ~es ~ ~r~r~*e See[ *o be ~ixed, and *hese pre~n~ *o be subserved b? · ~j~ of *he s~d ~rd es of *his 7 A~os~er (Absen~ T~tees Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD April 9th 2008 Alfred & Mary Magill 700 Glen Ct. Cutchogue, N.Y. 11935 RE: 1145 Fleetwood Rd. (New Dwelling) SCTM # '137. -4-26 Dear Mr. & Mrs. Magill, Please be advised that your Building Permit # 30304 issued May 10t", 2004 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued pdor to use of the structure. To renew your Building Permit, please submit a fee of $1634.30.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, $OUTHOLD TOWN BUILDING DEPT. Southhold Building Dept. Att: Pat Conklin In summary of our phone conversation on 9/2/05, I have sent this letter as was suggested to document this complaint. Alfred Magill of 1145 Fleetwood Rd. is planning on adding a 2 story garage on the original footprint of the old garage. He already has approval from the zoning board. The side wall height to the eaves is 15 ft. 11 in. and the peak is 20.6 ft. Neighbors had opposed a tall garage at the hearing and the first drawings for a 23 ft. tall garage were rejected and it was lowered to this height. However, in digging out the basement for the house which is being constructed now, the grad where the previous garage sat has been raised several feet. All neighbors, including Fleets Neck president Tom Wetzel can testify that there was a retaining wall and several cement steps in back of the garage which led up to the house. The variance states that the new garage must be on the existing grad. which was inspected at that time. We want to see this enforced. If allowed to build on higher ground, the garage will appear even taller and obstruct views further. You said someone from your department was already scheduled to visit the site Wed. Thankyou very much for your cooperation in ths matter. If for any reason you need to contact me, please call my office (Graphic Avenues Inc.) at 212-818-0902. Sincerely, Clifford Ohl- 1330 Fleetwood Rd. Permit Number Checked By/Date REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSothvare Version 3.5 Release lc Data filename: C:~Program Files\Check~REScheck\MAGILL.rck TITLE: MAGILL COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE: Non-Electric DATE: 01/21/04 DATE OF PLANS: JANUARY.21.2004 PROJECT INFORMATION: NEW RESIDENCE COMPANY INFORMATION: CHARLES M. THOMAS ARCHITECT COMPLIANCE: Passes Maximum UA = 453 Your Home UA - 422 6.8% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1139 30.0 0.0 Wall 1: Wood Frame. 16" o.c. 2709 15.0 0.0 Window 1: Wood Frame:Double Pane 432 Door 1: Glass 40 Door 2: Solid 40 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 1455 19.0 0.0 40 169 0.280 121 0.340 14 0.240 10 68 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans. specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requiremems. When a Registered Design Professional has stamped and signed this page, the2 are attesting belief, and profe~ionat ju~gment, such plans or specifications are in ~/~l ~ ~ Builder/Designer Date REScheck Inspection Checklist Ne~; York State Energy Conservation Construction Code .RES checkSol~are Version 3.5 Release 1 c DATE: 01/21/04 TITLE: MAGILL Bldg. Dept. Use [ ] [ ] [ I [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Pane, U-factor: 0.280 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ Comments: ]Yes[ ]No Doors: 1. Door 1: Glass, U-factor: 0.340 Comments: 2. Door 2: Solid, U-factor: 0.240 Comments: Floors: 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials, lfnon-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside theSuilding must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. [~] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] Insulation is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table,~: Mlnimumlnsulation ThicknessforClrculatingHotIfaterP~oes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating; Runouts Temperature (F) Up to 1" Up to 1.25" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Circulating Mains and Runouts 1.5" to 2.0" Over 2" Table 2: Minimum Insulation Thicl~ness for HV/IC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pipinl~ System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 Low Temperature 120-200 0.5 1.0 Steam Condensate (for feed water) Any 1.0 1.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 and Brine Below 40 1.0 1.0 1.5 2.0 1.0 1.5 1.5 2.0 0.75 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) COMPLAINT REPORT NAME: ~r.t~-~ I \ DATE ADDRESS: ~ }!q~ "~!a~--~:,,,,~,fl ~ PHONE ~ HOW RECEIVED: - TEL.~ -MAIL- 1N PERSON LOCATION OF COMPLAINT: SUFF. CO. TAX MAP # I.~ O~ERS NAME: ~ ~.~. ~6 NATURE OF COMPLAINT: ~ ASSIGNED TO: INSPECTION DATE: FIL~E# IF A~ RE-INSPECTION DATE: /,~ o,~ - / 3 ? - :y'- ~r. TOWN OF SOUTHOLD PROPERTY IIEC"ORD CARD OWNER STRE~//~/~- V,LU, G~ D,ST. SUB. LOT leS' ~/~ 'S~S- ~ FA~ COMM. CB. MISC. Mk~. Value AGE BUILDING CONDITION ~jl~J~ 6P~;&s~ odd N~ NO~L BELOW ABOVE FA~ Acre Value Per Value Acre Fillable 2 'illable 3 /~ Vo~land ;wampland FRO~T~E ON WATER ~d ~' Irushlond FRONTAGE ON ROAD ~ ~ BULKH~D 'oral D~K COLOR TRIM M. Bldg. Extension Extension Extension Porch Breezeway Garage I=~- X~'° - ,P- '~ o Foundation Basement Ext. Walls Fire Place Type Roof Recreation Roon~ Dormer Driveway Patio O.B / Bath Floors Interior Finish Heat Rooms 1st Floor Rooms 2nd Floor KDinette LR, DR. FIN. B, BR. TM 1000- 157-04-26 GUARANTEED TO MA OIL L NOTE: T/NC ON SITE. KHEADEZ BOA T SLIP REMO~EO, AND BACKFIL£EO. NJF R YBE CK Y ,'59' 27' 40" E FRAME CARA CE 2-STORY 25. O' BLUESTONE DRI VEWA Y BEDROOM 7CE 48,5' CHIMNEY S 40 00" W PROPOSED NEW CESSPOOL PIPE CESSPOOL N/F CAMPBELL (SEASONAL USE). TEST HOLE DATA PERFORMED BY McDONALD CEOSCIENCE 24 FEBRUARY 200,5 ~- EX/ST/NC G'RAD~ BROWN SILTY SAND SM PAl E RA'OWN FINE TO M[ DIUM SAND ~P 264.05' FL OOD ". ZONE X FL OOD ZONE AE-8 GUARANTEES /ND/CA Ti D HERE ON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND 01,/ HIS BEHALF TO THE tiTLE' COMPANY, COPt iCNMENTAL ACENCY, LENDINC INSTIIUTION, iF LISTED HEREON, AND TO 7FIE A~%!CNEE'~ O; TNE LENDINO IN~TITDTION CUARANTEE'] ANE NC) TRANSF£RABLE TO ADDI TIONA L INS [I f( / 7!( WZ OA' SDB'.?E(JDEN T 0 WNE 2. 27 FEBRUARY 200~ SHOW PROP. DWELL/NC NOTE:1. 29 JULY, 2002 SHOW ADDITIONS SURVEY OF D£~cCF~//~ED PF~OPEF~ TY SI TUA TE CUTCHO~U£, TOWN OF SOUTHOLD SUFFOLK COUNTY, N. X SURVEYED FOR MACILL RESIDENCE ,FLOOD MAP DATA FRO~z[IRI~'~,tAP~610,~C0164G F-~FFEOnVE DA~E ~ MA~9~ ~ ELEVATIONS IN 1929 NCVD SURVEYED 03 APRIL, 2001 SCALE 1"=50' SURVEYED :~ .,.. ..~ STANL~.r(~. t,,,~KSEN, JR. P.O. B~294 NEW SUFFOLK, NY 11956 6c Ns XND NYS LI~. NO. 010997 N 39'27'40"E u'z°' POURED CONCRETE o 12180' S 40'04'00"W I N/F CAMPgELL 320.36' TM# 1000-137-04-026 SURVEY OF DESCRIBED PROPERTY SITUATE CUTCHOGUE, TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. SURVEYED FOR: ALFRED A. MAGILL MARY M. MAGILL SURVEYED: 3 APRIL 2001 SCALE ?'= 30' AREA = 15,081 S.F. OR 0346 ACRES GUARANTEED 70: ALFRED A. MACILL MARY M. MAGILL SURVEYED BY STANLEY d. ISAKSEN, JR. P.O. BOX 294 ~/~EW SUFFOLsX~. N.Y. 11~56 yb l~. No. 492/~ 0~Cq97-1 4 · S 79~.4j,3~,,E · ?4' JAN 15 2010 BtDG· DEPI'. TOWN OF SOUTHOLD SURVEY OF PROPERTY SITUA CUTCHOGUE TOWN OF SOUYHOLD SUFFOLK COUNTY, NF'W YORK S.C. TAX No. "1000-157-04-26 SCALE 1"=40' APRIL 5, 2001 APRIL I2, 200,5 SHOW POURED CONCRETE FOUNDATION. SEP. 28, 2009 SHOW GAP, ACE, SANITARY, GARAGE ELEVATIONS, HOUSE MEAS. DECEMBER 10, 2009 ADDED SEPTIC SYSTEM STRUCTURE OUTLINES AREA : 15,081 sq. ff. 0346 oc. CERTIFIED TO: ALFRED A. MAGILL MARY M. MAGILL NOTES: 1. SANITARY AND WATER LINE LOCATION AS PER OWNER ELFVATIONS TAKEN TO SHOW HEIGHT OF GARAGE IS AS FOLLOWS: ELEVATION OF POINT ~5 (RIDGE) : 40.7 ELEVATION OF POINT ~= ELEVATION OF POINT ~2 = 20.6 ELEVATION OF POINT ~5 = 22.7 EL~/ATION OF POINT #4 = 19.7 ~04D N.Y.S. Lic. No. 50~67 Nathan Taft Corwin III Land Surveyor , PHONE (651)727-2090 Fex (651)727-1727 Permit Number Checked By/Date REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSofa,vare Version 3.5 Release 1 c Data filename: C:~Program Files\Check~REScheck\MAGILL.rck TITLE: MAGILL COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric DATE: 01/21/04 DATE OF PLANS: JANUARY,21,2004 PROJECT INFORMATION: NEW RESIDENCE COMPANY INFORMATION: CHARLES M. THOMAS ARCHITECT COMPLIANCE: Passes Maximum UA = 453 Your Home UA = 422 6.8% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Tress 1139 30.0 0.0 Wall 1: Wood Frame, 16" o.c. 2709 15.0 0.0 Window 1: Wood Frame:Double Pane 432 Door I: Glass 40 Door 2: Solid 40 Floor 1: Ali-Wood JoistJTruss:Over Unconditioned Space 1455 19.0 0.0 40 169 0.280 121 0.340 14 0.240 I0 68 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet,,~e New York State Energy Conservation ~l~sa:ugtion Code requirements. When a Registered Design Professional has s~ta!lllS~'and signed this page, they are attesllielt, .~0 the be~i'of his/her knowledge, belief, and professional judgment, such pl~s/or · specifications are in complian~e,!~ th~ C,~e. Builder/Designer ~,',' ' ~ Date '~' ': REScheck Inspection Checklist New York State Energy Conservation Construction Code RES check Sot~ware Version 3.5 Release 1 c DATE: 01/21/04 TITLE: MAGILL Bldg. Dept. Use [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ I [ ] [ ] [ ] [ ] [ ] [ l [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall h Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Pane, U-factor: 0.280 For windows without labeled U-factors, describe features: # Panes__ Frame Type Thermal Break? [. ] Yes [ Comments: ] No Doors: 1. Door 1: Glass, U-factor: 0.340 Comments: 2. Door 2: Solid, U-factor: 0.240 Comments: Floors: I. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ,, * Insulation is not required on return ducts in basements. Duet Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State ,the Residential Code of New ¥ork State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part ora circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heuting and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. · ~able 1: Minimum Insulation Thickness for Circulating Hot [Eater Pipes. Insulation Thickness in inches by Pipe Sizes Heated Water Non-Circulatin8 Runouts Temperature (F) Up to 1" Up to 1.25" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Cimulatin~; Mains and Runouts 1.5" to 2.0" Over 2" Table2: Minimumlnsulation ThicknessforHV,4CPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pi~ing System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 Low Temperature 120-200 0.5 1.0 Steam Condensate (for feed water) Any 1.0 1.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 and Brine Below 40 1.0 1.0 1.5 2.0 1.0 1.5 1.5 2.0 0.75 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) I"X2" TRIM ON I CEDAR D452 RAf~.EFRIEZE ~T %0 FI~T EDOOR ASPHALT ~HIN~LE ROOFINE, ASPHALT SHIN~LE~OFIN~ D ~ OCOUPANCYOR USEIS UNLAWFUL ¥flTHOUT CERTIFIi~TE! OF OCCUPANCY PLUMBER CERTIFICATI~I ON LEAD CONTENT BEFORE OF OCCUPANCy IN WATER CANNOT 0 OF I% LEAD. PLUMBING AU-PLUMBING WASTE & WATER UNE8 NEED TESTJNG BEFORE COVERING N.I. CONSTRUCrloN,a~Nj. MEET THE REQUIREMENTS OF THE Ft ONT ELEVATION SCALE: I/4" : I'-0" ELEVATION SCALE: I/4" = I'-0" UNDERWR~RS CERTFICA~! PERFECTION VENT CEDAR PERPECTION SHiNgLE55 APPROVED AS NOTED DATE:~ B.P. # ~O~c~ SIDE ELEVATION SCALE: I/4" I '-0" CEDAR =ERFEDTION FP--.O NT ELEVATION NOTIFY BUILDING DEPARTMENT AT 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.C. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE, NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERROP~. CERTIFICATION OF NAILING & CONNECTIONB REQUIRED. STATE COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AB REQUIRED AND CONDITIONS OF ,.41/t~ so~'ro~z~ ~ N.Y.S. DEC ~LO01) [01~~ DO NOT PROCIEED WITH FRAMING UNTIL SURVEY RETAIN ~ WA"I~R RUMOFF OF FOUNDATION LOCATION PURSUANT TO SECTION 48-10C HAS BEEN APPROVED, OF TIlE TOWN CODE. VENT SCALE: 11/4" = I'-0" -- ASPHALT SHINGLE Z SHT. 2'-5" 2' I0" 2~-I0'' \ \ / ~ I I,-1ASTE-~ \ I I~ATH \ t'4A.STI~ BEDROOIH \ C,,LO~ET \ BEDROOI,4 206D 5'-5" / t 1 OPEN T¢ ~LOIN .~C, ALE: 1/4" I'-0" -d 25'-5" -2-2"×6" (T'Kp) RIP OOHN 2"x4' AND SPIKE D/4"PLYHOOB) 5 HEATHIN~, 24'-5" KITCHEN 2010 5TUD"r' FOYEE SCALE: RLAN I/4" = I'-O" FhlOCOCII (BEE [~ETAIL H ~2 X 45 PIPE OOLUHN b D-II ] TJI JOISTS L AE~OVE BOILER OOLL~t'"fN ON A CONCIR~TE FOORTf N~. L. -J 4" ~ CONO. 5LAB F L. J D - HL FLUSH L_ ~ L - HL FLUBH O" POUR,~ CONCRETE FOUNDATION ~'4ALL HITH 2-'5 BAR~ TOP AND BO~q'Oh~ ON IO"X20" FOUNPATION PLAN SCALE, I/4" I '-O" FOUNDATION 24~x24"xt2'' PC, FOOTIN~ HINIHUH 4~," BELON .11 II II .2__ OF 5 GUT~,II~ AIR FILM ASPHALT ROOF 5HINE~ P5 FEJ.T FL~ INSIDE AI~ FILH ~ T~ R I ~1~ I~1~ AIR FILM ~ ~1~ AIR ~ AIR ~ILH U VALUE OALOULATIONS R = .4.4 R= R = Iq. Go R = 11.4~ R= .~2 R= ~2 R = Iq.O0 R= .~1 R = 12.f~ 01~1[:~ AIR FILM R = .IT 61~)AR/VINYL (A'vI~R,'~J R = ~q T1~ R=~ [' ~ ~l~ R = .~ ~ ~" ~ I~TION R = I~ ~IL F~) V ~. ~. I~l~ AIR FILM R = ~ E)EOF-- F~AivlING DETAIL SCALE: N.T.S FIRST PLUWSING ~.ISE~ ;?IAGP-.AH SCALE: N.T.S SEE ;?ETAIL SHEET FOP-- OF)ENIN~ F~.OTE~OTION E~'C !4OOE) STI~.UOTU~AL_ PANELS PUP-.SUANT TO I©oq.l.4, SEE FASTENIING SOHEi?ULE ON i?ETAIL SHEET I~ THIS SET DESIGN CRITERIA ~OmD NIN~ 5EISHIC 5UBJECT TO DAHACE FROH HINTER ICE SHIELD FLOOD _IVE DEAD : ~LL ~ATHIN~ USE/ HEICHT FI~ ~PE OF 5NOH ) 5P~D DESICN FROST DESIGN UND~AYHENT HAZA~5 _CAD .CAD ROOF UPLIFT LOAD ~CTION ILOAD OCCUPANCY AREA CONSTRUCTION LO~ (HPH) OA~RY _INE CLASSIFICATION HEATHERIN~ DFPTH ~RMI~ DECAY ~MP, ~OUI~ GENERAL NOTES ATTIC CONSTF/.UCTI ON TYPICAL FLOOR CONSTI~-UCTION FLOOR UOISTS* i~," cc. ~ ~/4" PL'r~ooo ~UB*UOOR BATH T'fPICAL !~A, LL CONSTRUCTION 4" POUf~4~D CONC, I~ETE OLAB 4 HILL VAPOR BARRIER SEOTION SCALE, I/4" = I'-©" SHT. 5NoJ Ft:P-.ONT ELEVATION SCALE, I/4" ['-O" SIDE ELEVATION GOALIE: I/4" = I'-O" SCALE~ I/4" = Ft~ONT ELEVATION SCALE: 114" = I'-0" z Ill d I SHT. No. TYPICAL ROOF CONSTRUCTION J L4" POUt:~.ED OONORET~ ~LAB SCALE, I/4" = ILO`' T'FPICAL HALL CONSTRUCTION 8" POUF-ED 60NORETE FOdNOATION NALL ON A 8" X IS" POt)P/ED i- k L. ,$ '$ II ~/8 TJI JOISTS ¢ I~'" OG %'% %%, 4" P~ DROP FOUNDATION HALL FTO MEET 5LA~!I SCALE: I/4"= t'-O" FIRST FL_OOP--. PLAN SCALE: I/4" = I'-0" r CONTINCk2U~ FOOTINC, UNEXCAVATED FOUN~ATIO_N PLAN SCALE: I/4" = I'-0" Ill r',E 0 SHT. No. 5 -%, ,f r ,SECOND 5TORY FLOOR JOIST- SEE DRILLIN¢ AND ~fHIN6 PROVISION5 SECTION 3.3.1.1.t JOIST OR BLOGKiN6 PLATE FOUt~ATION JOIST 15 PERHH BE CUT SEE DRILLINe AND NOTCHINg PROVISION5 _ STUD- SEE DRILLIN® AND NOTCHIN5 PROVISION5 HFCH SECTION 3.4.1.1.1 AND E~IDelN~ 5E-E HFCH SECTION BLOCKED A®AINST ROTATION IN ACCORDANCE HITH HFCH 3.3J.5-END R~ST~kJNT AND 3.3.1.4 BRIDelNe, IN. HIN. IN,x4 iN. RIBBON INTO 5TIJD - FOR FIRE BLOCKIt`4~ HONOLITHIC 5LAB-ON--DE FOUNDATION CORNER AND PARTITION POST5 ~OTT~l~ 5tug AND/OR PARTITION INTERSECTFIN~' BACKINg, STUD5 .SHALL BE PERHI I I ~'u TO B OHi II~D TH1ROUC,~ THE USE OF HOOD BACKUP CLEAT5 OR IHETAL DRYHALL CLIP5 THAT HILL SERVE A5 ADEQUATE BAGKIN6 FOR THE FAGIN6 HATERIAL. FRAVIING DETAILS lcd NAIL AT 24" O.C. NAIL AT 6" O.C. LL PANEL EDE, EB) ®¥F:'BH BOARD NBTALLED IN ACCORDANCE HITH HFCH TABLE 3. L ' HOOD STRUCTURAL PANEL NSTALLED IN ACCORDANCE HITH J, fCH TABLE :5. 8Ct NAIL AT 12" C.C. ON ALL FRAHIN® PtEHBEP,.5 NOT AT PANEL EDGES (a) OUTSIDE CORNER DETAIL PLATPORH FRAHIN® TYPICAL MALL, I NTERHEDI ATE DEARIN,¢ HALL · BALLOON FRAHIN® FLOOR ANP ROOF FRAHING ENDHALL ININD-BORNE DEB, RI5 PROTECTION FASTENIN® SCHEDULE FOR I,'~OOP 5TPJJCTdRAL PANEL5 ~ F/ ,.~TENER SPACIN<4 i FASTENER 2 FEET 4 FEET 6 FEET PANEL 5PAN ( PANEL 5PAN ( PANEL 5PAN ~ PANEL 5PAN i''Df'I'~z ( 2 FEET ,~; 4 FEET .4 ,~ FEET ( 8 FEET ' 2 {/2" I~ 16,, 16" 12" q,, O,'THI~ TAE~LE EABED ON I10 ~ ~lll~ BFI~¢5 AflP A 33 FOOT MEAN ROOF HEIC-~'4T. b; FA~ 5HALL BE INSTALLED AT OPPOSIN~ END5 OF THE HOOP 5TP, DCTURAL PANEL. c. HALLO 5HALL BE IOd COHHON OR 12d BOX NAILS. ct. ~ 5¢_,,REH5 ARE ATTACHED TO HASONR¥ OR HASONR¥?STUCCO, THEY 5HALL BE ATTACHi~) t)TILIZINE. 'v'I~RATION-RESISTANT ANCHOR5 HAVIN¢ A HINIHUH ULTIMATE HITHDRAHAL CAPACITY OF 4qO POUN[~. ~. HOOD 5"rRt~TURAI.. PANELS 5HALL_ HAVE A HINIHUH THICKNE55 OF 7/t6 INCH (lI.I m) LAVATORIES )F~NIN~ SHO!/qER HINIHUH FIXTURE CLEARANCES BLOCKIN¢ 4 2I" .~ARANCE EXTERIOR CORNER FRAHING A HAi~K CLOSET OR BtPE-T,~LS~ ~AL, L 21" CIEARANCE HATER CLOSET5 FLOOR BRACIN® AT END (MFC, H FIGURE ~.0b) NO 6 E~ DIApiHRA~H REGdlRED NAIL AT 4" O.C. -- ROOF P-.AFTtEF~ TOP PLA~i 'BORED HOLE5 5HALL NOT ×lll .BE LOCATED IN THE 5AHE OR055 SECTION OF ddt OR NOTCH IN 5TUB NOTCHING MFd, H Iqq5 SBC HIGH HIND EEPlTION SECTION 5.4.5.1.1 AND BORED HOLE LIHITATIONS GABLE FOR SECTION A-A INTERIOR NONBEARING MALLS BAYS ~ ~2' ~A,,<. _1 ~N~A~tp.L~ BASED ON 5HEAR HALL REQUIREHENTS / ~ CENTER 2x BLOCKIN~ ON SNEATHIN6 JOINT : i5/32 HOOP 5TRLk~TUP. AL PANEL5 ON 6ABLE FACE AND ON HALL BELOH BASED ON .SHEARHALL REOUIRE~ENT5 ENDHALL, BALLOON FRAMING PREFERREP HETHO~ H/2 BUT NEED EXCEED t5 FT. BORED HOLE HAX DIAHETER 40% OF 5TUB DEPTH 5/D" t`dlN, TO ED¢E NOTCHt HUST NOT EXCEED 25% OF STUD DEPTH -- STUD 5/8" HIN. TO EPeE IF HOLE IS BET!NEEN 40% AND 60% OF 5TUP DEPTH, THEN 5TdP HUST BE ~ HO~5 ~L NOT DOUBLE A~ NO HORE ,THAN T~ ~ L~CA~D IN t~ 5A~ ~GC~l~ 5~ ARE ~LED CPO55 SECTION OF 6~ OR I A~ ~ ~p NOTCH IN 5~g HFCH Iqq5 550 HIGH ~fND EPlTION SECTION 5.4.1.1.1 FIGURE 5.25 NOTCHING AN~ 5ORE~ HOLE LIHITATION$ FOR EXTERIOR MALLS ANP BEARING MALLS NOTE: UPLIFT CONNECTIONIS REGUIRED ATEAGH END OF HEADER AND AT BOTTOM OF HEADE~STUD5 IN ADDITIONTO CONNECTOR5 AT HALL STU~5 AND AT TOP AND BOTTOH OF CRIPPLE-'5 5d COOLER NAIL5 TYPICAL FRAHING AND UPLIFT ' CONNECTIONS FOR OPENINGS · FACE OF FOOTH~ 2-1od NAIL5 CLEARANCE Ft OFI SLOPES FOUNDATION RTPSUH BOARD 5d COOLER NAIL5 AT T" O.C.-- IO-bd NAIL5 ENDk4ALL GABLE ENPJ4ALL BRACING . (14FOhl FIGURE 5.60) P-.I D®E DEAH TENSION EXTERIOR OR BEARIN~ HALL TRU55OR CEILIN~JOI5 ~RIDC-~ TENSION STRAP USE 8-8d COHHON ,,N~.IL IN EACH END OF I-I/4 2~) ®AUC-.~E STRAP STRAP PETAIL c-jC, A, LE: N.T.5. NOTCH C-P~ATER THAN 50¢6 OF THE PLATE HIDTH -- 20 ®A. STP. AP ~,A~E i IANDiI.~" HIDE TAL TI[ SS At' P TO EACH k4/(8) 8d NAILS 51DENA~LsOFEAcHTHE SIDENOTCH HITH 8-1Od EACH SI~E Simpson Sf. rong-Tie A35- Chimney Framing PIPE ~Ad NAIL AT 6" O.C. LL PANEL EDGES) NAIL AT 24" O.C. TOP PLATE FRAHING TO ACCOI'dPIODATE PIPING F®TPSH BOARD INSTALLP-D IN · , /ACCORPANCE HITH NFC',H TABLE ~.[ ~-HOOD 5T~CTU~ PANEL INSTALLED IN ACC, ORDANCE HITH ~FCH TABLE 3.1 ~l NAIL AT ~" O.C. ON .N_L FRAHIN¢ HEHBER5 AT PANEL EDEn5 AND I2" O.C. ON ALL FP-,AHIN~ T`'IEHBL~5 NOT AT PANEL EDC2E5 Simpson S~rong-Tl¢ E)E l'Alt_ (b) INSIDE CORNER DETAIL EXTERIOR CORNER FRAMING TABLE P-.50t .4 h,llNIh'lUl'd UNI FOFP-J'dL'r' LOAIPS (PSi) _IMF: LOAD USE .- EXTERIORBALC~. NIE5 (20 PECK5 40 ATTIC ~ITHOUT S¥OF~..A~E I0 ATTIC5 P41TH 5TOI~&.C~E ' ,20 t~.OOPl5 OTHER THAN 5LEEPIN~ t~OOP'~ 40 C.~UA~J:)~'AIL5 ANI~ HANDRAIL5 200 (TABLE 5.1 HFCH HIGH HIND EDITION) NAILING SOHEDULE JOINT DESCRIPTION NUHBER OF NAILS NAiL SPACIN® P-,AFTE~ TO TOP PLATE (TOE-NAILED) .+-Sd PER RAFTER CEILINO JOIST TO TOp PLATE ( TOE-NAILED) 4-8d PER JOIST CEILING qOIST TO PAP. Al I FI RAFTER ( PAOE-NAILED) q-lbd ___ EAOH LAP CEILIN6 J~. 1ST OVER PARTITIONS (FACE-NAILED) q-lCd EACH LAP CJ>LLAR TIE TO RAFTER (FACE-NAILED) 6-8d PER TiE BLOCK. ~ TO RAFTER (TOE-NAILED) 2-8d EACH ENO TR~F1 BOARD TO RAFTER (END-NAILED) 2-Ibd EACH END NALL FP-AMIN® TOP PLATE TO TOP PLATE (FACE-NAILED) 2-1&d (SEE NOTE I) PER FOOT TOP PLATE AT INTERSBOTION (FACE-NAILED) 4-16d JOINTS-EAC, H SIDE ,STUD TO 5,IUD ~AC, E-NAIILED) 2-16d 24' D.C. NE.~[;~:~. *¢0 HEAOER ¢=~7¢E-NAILED) Ibd 16" O.C. ALON¢ TOP OR' BOTTOI,,1 PLATE TO STUD (END-NAILED) 2-16d PER 2X4 STUD ~-~cd PER 2x6 sTUD 4-16d PER 2X8 STUD BOTTOM PLATE TO FLOOR JOIST, BAND JOIST, END JOIST OR BLOCKIN® ' FAcE-NAILED) 2-18d (SEE NOTE f,2) PER FOOT ' FLOOR FRAMIN¢ JOIST TO SILL, TOP PLATE TO 61ROER (TOE-NAILED) 4-8d PEP- JOIST B~ID~IN6 TO, JOIST ~OE-NAtLED) 2-8d EACH END BpC:~DKINO 1-O SILL OR TOP PLATE (TOE-NAILED) __ D-lCd EACH Bk_OCK _EDGER STRIP TO BEAN (FACE-NAILED) Dq6d EACH 4OIST JO 5T ,ON LEDGER TO BEAM (TOE-NAILED) ~-Sd PER JOIST ~-tCd PER JOIST BAND JOIST TO JOIST (ENO-NAILED) __ BAND JOIST TO 5ILL OR TOP PLATE (TOE-NAILED) ~-tCd PER JOIST ROOF 5HEATHINO STRUCTSRA~- PANEL5 8d (SEE TABLE ~.8) DIACONAL~ BOARD SHEATHIN6 I"XC" OR ¢'X8" 2-8d PER SUPPORT ~-Sd PER SUPPORT I~XIO" 01~ HIDER ~ CEI~tN® SHEATHIN® ¢IPSU,H HALLBOARD [ 5d GOOLE-R~ I I" EDC¢~ / Ia" FIELD HALL 5HEATIHN® STRUCTURAL PANELS ~d (DEE TABLE FIREBOARO PANELS '~/16" (~d ~" EO®E / 6" FIELD 25/32" bd 3" EDGE / 6" E~ELD Gipcj~H,HALLBOARD 5d COOLER9 __ I" EDGE / ID" FIELD -~ARDBOARD ~d (SEE TABLE ~.~) PARTICLE=BOARD PANEL 8d _ (SEE TABLE ~.q) DIACONAL BOAP-,D 5NEATHIN® I"X~" OR I"X~" 2-8d PER SUPPORT I"XIO" OP. HIDER ~-Sd PER SUPPORT FLOOR SHEATHI) ¢ 5Tt~CTUP-.AL PANEL5 I' OR LESS 5d 6" EDCSE / 12" FIELD 6Pd~ATER THAN I" lcd ~" ED®E / 6" FIELD DIACONAL BOARD SH~ATHIN6 II'X6'' OR I"XS" 2~8d PER SUPPORT I"XIO" OR HIDER ~-8d PER SOPPORT L ~tL f~-E~IRL=~'~'NTS At24~A B~ED ON J,JALL SHEATHIN¢ ~I~D ~" ON-GEN~, AT THE PANEL BOSE IF ~LL 5~ATHIN¢ 15 NAILED 5" ON-C~N~R AT ~ P~ EP~ TO ~TAIN HI~R ~R CAPACITIES. NAILIN¢ ~UI~E~NT5 FO~ 5~G~L MEHBE~ SHALL BE D~BLED, OR AL~RNATE GONNEGTOR~ ~&L ~ U~D TO HAI~AIN t~ LOAD PATH, 2. ~ ~L %:~1~ OONTI~ O~R CON~CTEO HEH~, THE T~ULATED ~R OF NAIL5 SHALL ~ PERHI~D TO ~ ~OUC~ TO t-Sd ~IL ~ MT. TABLE D2 AHFCH HtSH HINO EDITION) . SILL OR DOTTM PLATE TO FOUNDATION ANCOR ~OLT CONNEOTIONS ~SISTIN¢ LATERAL ~ SHEAR LOADS A~NC. HOt~. BOLT GONNECTIOIF:OUNIDATION BRAGIN¢ MALL PERh'IITER k1AXtHUbl ANCOR BOLT SPAGtlN~ SUPPORTIN~ ED®E NAIL SPACIN¢ (IN) (l/2 ANCOt~. BOLTS) SILL PLATE TO FOUNDATION I STORY ALL __ 4~ CRA]NL SPACE ~ ~A~:~Ef'JENT) 2 STOf~¥ 2D 2~ ~L BO~OH PLA~ TO POU~ATION i-2 STORY ~ Iq (TABLE -~2 AIAIFGPI HIgH kqlNE) EDITION) SILL OR BOTThi PLATE TO FOUNDATION ANGOR BOLT CONNECTIONS RESISTIN~ LATERAL ~ ~HEAR LOADS SHEATHIN® LOCATION STUD SPAGIN® BRAGIN® HALL PERbllTER i'dAXlblUkl NAIL SPACIN¢ ' OR PANEL SIPlN¢ FOR ~d GOMHON NAILS 4" ~ Z~ F i2 (~ NO~ 22 I/2" Anchor ~olLe (SST~-28) See charL on bhl~ ~h~6 for sp~clng T~8k house~r~p. p~rc. ent stop~), overloppl~ SENERAL UPLIFT - CONTINUOUS PATH CONNEGTOI~.S ANCHOR t~:DLTS IN FOUNDATION USE= SSTB28 ~IITH BEAI~IN~ PLATE, SEE FOUNDATION SILL PLATE TO RtPt JOIST USE, HTSI2 @ EACH JOIST PORCH POST TO DECK USE: PST20 (AL~N HItH JOl~t tDELOM) 51MSON STRON¢ - TII HSTA¢6 FLOOR TO CONNECTION SIHSON 5TRON6 - TIE HTSDO OR HSTI2 SILL RIM PLATE TO JOIST TO ST~ON~ - TIE ,12 RIM JOIST AND STUD CONNECTION STOP TO ROOF RAFTER CONNECTION Y/%kSLF 39 SHEATHING LOCATION STUD SPACIN® STRUCTURAL SHEATHIN¢ klAXliVtUiVl NAIL SPACt'N® OR PANEL SIDIN® FOR 8~d COMMON NAILS (S~E NOTE I] (INCH~S O.CJ (SEE NOTE ~) I/2" ANClJOf~ 4" PE~I~D '- E INTEJ~IOF~ ZONE E F E F NAIL SPACINg, AT PANEL ED~E (IN) 12 (~E NOTES 4 (SEE hOTE 47 4 (SEE NOTE