HomeMy WebLinkAbout34369-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
NO: Z-34581 Date: 09/28/10
THIS u~TIFIE$ t~at the building ACCESSORY GARAGE
Location of Property: 1565 JACOBS LA SOUTHOLD
(HOUSE NO.) (STREET) (HAMLET)
County Ta~ ~ap No. 473889 Section 79 Block 6 Lot 4.3
Subdivision Filed~4ap No. __ Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JANUARY 2, 2009 pursuant to which
Building Permit No. 34369-Z dated JANUARY 2, 2009
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ACCESSORY UNHEATED GARAGE AS APPLIED FOR.
The certificate is issued to JACK H & KAREN M THILBERG
(OWNER)
of the aforesaid building.
SoF~OI~KCO~I~YDEPART~ENT OF HEALTH A~PRO~FAL N/A
ELECTRICAL c~TIFICATE NO. 09-163 09/02/09
pLD]~ERS c~TIFICATION DA'£~4~ N/A
Rev. 1/81
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 34369 Z
Date JANUARY 2, 2009
Permission is hereby granted to:
JACK H & KAREN M THILBERG
1565 JACOBS LANE
SOUTHOLD,NY 11971
for :
ACCY UNHEATED GARAGE IN REQUIRED REAR YARD OF EXISTING SINGLE
FAMILY DWELLING AS PER PLANS SUBMITTED
at premises located at
County Tax Map No. 473889 Section 079
pursuant to application dated JANUARY
Building Inspector to expire on JULY
1565 JACOBS LA SOUTHOLD
Block 0006 Lot No. 004.003
2, 2009 and approved by the
2, 2010.
Fee $ 596.00
Authorized Signature
ORIGINAL
Rev. 5/8/02
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
Bo
For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction: Old or Pre-existing Building:
Location of Property: /~'~/. ~-'~' ~J-,~O'_~i>6~' ~.
House No. Street
Owner or Owners of Property:
Suffolk County Tax Map No 1000, Section ~7 7
Subdivision
Permit No. s~__~C', ~:~'~ ? Date of Permit.
Date. ~-~c~',~7'"- ~.L.~ ~0 [0
(check one)
Hamlet
Block ~ Lot ~ 3
FiledMap. ~ Lot: ~
Applicant:
Health Dept. Approval:
Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate
Final Certificate:
(check one)
Fee Submitted: $
- "~l~plicant Sign'~Fuure~"
/
l~= E= I. EAST END INSPECTION AGENCY, LLC
RO. BOX 35
EAST QUOGUE, NEW YORK 11942
631-594-2272 Fax 631-594-2272
www. eastendinspections.org
CERTIFICATE OF ELECTRICAL COMPLIANCE
Owner Jack ?hilberg
Addmss: 1565 Jacob Lane
Scutholdr ~¥ 11971
Cert. Non Q_ 1; ~
Location of Pmoe~v Inspected
1565 Jacob Lane, $outhold, NY
Location Cr~es Street SCTM~ (if applicable) Dlst Sec Block __Lot
( ) Commercial ~) Residential ( ) Industrial ( ) Other
( )Basement ( )lstFIoor ( )2ndFIoor ( )3rdFIoor (x)Garage ( )SwlmmingPool ( )HotTub ( )Sewica
( )New ( )Addition (~[Renovation ( )ElecbicalSurvey ( )Other
Receptacles Switches F~'ure Outlets
(2) (3) (1)
GFCl Dishwasher Washer
(1)
Bell Trans Dimmers Unit Heaters
Special Recap Track Lighting Pool Pump
(1) 50map
co Detectors Smoke Detectors NC Units
Size Service Service Disconnects
existing
Sen/ica Underground Service Overhead
Incandescent Fixtures
(1)
Dryer
Hot Water Heater
Pool Heater
Other
Service Meters
Other
(1)4-50
Installer: ~
Electrical
Flourescaot Fixtures (Nh Fix
Range Ceiling Fans
Fumaca Motors Multi Outlels
Pool Light Time Clock
Other Other
Service Conductors Size/Phase
Other Other
Uc.#1022E
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
FO U.DA,NSPECTION
ION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND
[ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [
REMARKS:
] FIRE RESISTANT PENETRATION
DATE -~~ INSPECTOR/~. /~ ~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] I/.~ULATION
[ ] FRAMING / STRAPPING [/'] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SA,-.., f INSPECTION
[ ]FIRERESlSTANTCOIISTRUCJiOH [ ]FIRERF..SISTANTPEHETRATIOH
DATE
INSPECTOR
FIELD INSPECTION REPORT I DATE~ I
FOUNDATION (1ST)
FOUNDATION (2ND)
PLUMBING
INSULATION PER N. Y.
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net
Examined
Approved
Disapproved aJc
Expiration '7 //~' ,20
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying'?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mail to:
Phone:
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date
INSTRUCTIONS
,20
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. ~
t//~' (§i[n~ o{ a/lican_t~r name, if a corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises ,~-.~Z ~, 'T~ZL~__~ I~ ~
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No. 1~7-~ -
Plumbers License No. ~&
Electricians License No. /4&
Other Trade's License No. ~
1. Location of land on which nroposed work will be done:
House Number Street
Hamlet
County Tax Map No. 1000 Section ~/~
Subdivision ~ V~//_.&c'!
Block t~ Lot Z~. ~
Filed Map No. '1~_.~, Lot ,1~
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy ~ ~-~ ~cT-t_~ I~L, ~'~ ~
b. Intended use and occupancy ~/50,~
3. Nature of work (check which applicable): New Building
Repair Removal
Estimated Cos?~0 ~
Demolition
If dwelling, number of dwelling units
If garage, number of cars
Fee
Adflltion Alteration
Other Work
(Description)
(To be paid on filing this a~plication)
Number of dwelling units on each floor ~//b
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. D~ofexisting structures, if any: Front ~.~/ Depth
Height
Dim e n sion ~~tL~qo~9~d d itio n s: Front . Rear
Deptb-~ Heigh'~ ~r nf Stories
8. Dimensions of entire new construction: Front
Height I~ ~ ~:~tt NumberofStories
9. Sizeoflot: Front 1~),z/3 ' Rear
Rear ,~ t D~pth ~.~/._/ I
Depth ~ I
10. Date of Purchase l~)' lz~' ~. Name of Former Owner
11. Zone or use district in which premises are situated A ~-~
12. Does proposed construction violate any zoning law, ordinance or regulation? YES__
13. Will lot be re-graded? YES__ NO )~ Will excess fill be removed from premises? YES
14. Names of Owner of gremises "~~
Name of Architect ~KI ~[.y~"//2~ '
Name o f Contractor' Ibld~--'-/O/~ ~
NON/
15 a. Is this property within 100 feet ufa tidal wetland or a freshwater wetland? *YES__
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO~N~
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
__NO X
Address t.~14t~L~ Kjbl Phone No. ~_[~__7.~~'~
Address~:~*~ .Phone No ~ ~'7~,ZCl ~ qL:g,O
Address :12Z 9 Phone No.
NO
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO ~
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
COUNTY OF~1/~45~'0 ~:
~ ~ being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
CONNIE D. BUNCH
~,-~/t Notary Public. Slate of New York
(S)He is the . ~.
(Contractor, Agent, Corporate Officer, etc.) Qualified in Suffolk County
C0mmissi0n £xpir*s ^pd114, 20
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Swum to before me this dayof
Notary Public
20 C~c~
~/ ' S'ignat
~ ~f ~,p~l~cant
J lOC)() --f'~. ~ °~,.~ TOWN OF SOUTHOLD PROPERTY RECORD CARD [ ~ .', 4-
STREET/._~----~ ~' VILLAGE DIST. SUB, LOT ~
' I W TYPE OF BUILDING
RES. ~ j O 8~8. VL. FARM COMM.
~ND IMP. TOTAL DATE REMARKS
~ '~'~/
FRONTAGE ON WATER TILLABLE [' ~ '~'
FRONTAGE ON ROAD J~ WOOD.ND
DEPTH ~ M~DOWLAND
BULKHEAD HOUSE/LOT
TOTAL
Extension
Extension
Extension
Patio
Porch
Deck
o
COLOR
TRIM ·
Foundation
Ext. Walls
Fire Place
Bath
Floors
Interior Finish
Heat
Woodstove
Attic
Rooms 15t Floor
Driveway Rooms 2~d Roor
Town _of Southol d
Erosion, Sedimentation & Storm-Water Run-off A-~-~-~SMENT FOR.'"
PROPERTY LOCATION: S.C.T.M. ~:
THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF
$~'ORM-WATEI~ GRADING; DRAINAGE AND EROSION CONTROL
Ci=KTIFIED BY A DESIGN PR,,~r=SSIONAL IN THE STATE OF MEW
Item Number:. (NOTE: A Check Mark (~) for each Question is Required for a Complete Application)
Yes No
2
3
4
5
6
7
Will this Project Retain All Storm-Wafar Run-Off Generated by a Two (2") Inch Rainfall on Site?
(This item will include all run-off created by site clearing and/or construction activities as well as all Site
Improvements and the permanent creation of impewious surfaces.)
Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location?
This Item shall include all Proposed Grade Changes and Slopes Controlling Surface WaterFIowi
Will this Project Require any Land Filling, Grading or Excavation where there is a change to the Natural
Existing Grade Involving more than 200 Cubic Yards of Material within any Parcel?
Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of
Five Thousand (5,000) Square Feet of Ground Surface?
Is there a Natural Water Coume Running through the Site?
Is this Project within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach?
Will there be Site preparation on Existing Grade Slopes which Exceed Filteen (15) feet of Ve~cal Rise to
One Hundred (100') of Horizontal Distance?
Will Driveways, Parking Areas or other Impervious Surfaces be Sloped lo Direct Storm-Water Run-Off
into and/or in the direction of a Town right-of-way?
8 Will this Project Require the Placement of Material; Removal of Vegetation and/or the Construction of
any Item Within the Town Right-of-Way or Road Shoulder Area?
ti'his item will NOT include the Installation of Driveway Aprons.)
9 Will this Project Require Site Preparation within the One Hundred (100 Year Floodplain of any Wafarcourse? O
NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark in the Box, a Storm-Water, Grading,
Drainage & Erosion Control Plan Is Required and Must be Submitted for Review Prior to issuance of Any Building Permit!
l-Zl
r'c'-I x
I-Slx
EXEMPTIONt
Yes No
Does this project meet the minimum standards for classificat;on as an Agricultural Project?
Note: If You Answered Yes to this Question, a Storm.Water, Grading, Dralnage & Erosion Control plan is NOT Requlredl
STATE OF NEW YORK, ~ t~, ~, .
COUNTY OF ......................... ....'~... ........... SS
That I ................................................................................. being duly sworn, deposes and says that he/she is the applicant for Permit,
And that he/she is the
Owner and/or representative of the Owner of Owner's, and ~s duly authorized to perform or have perfornzed the smd work and to
make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and
that the work will be perfonned in the manner set forth in the application filed herewith.
Sworn to before me this;
FORM - 06/07
, ?L~MIN ER CItECILLIS [
CTM~ 1000 "Tq - _~ ~ Subdivision:
'roperty Address: /.~ S ~~ ~
F ' C
,~sUmated
Zone: ~ Confor'mi0g? ~
Ci,y: ~O/d P,'e COs'?
luildiug permi(s (Open/E×pired): BP -Z/C/O Z- , Info: BP -Z/C/O Z-
P__ -Z / C/0 Z- , [nfo: BP -Z/C/0 Z-____., Info: BP~ Z / C/0 Z
i~gle & Separate Search Required.'? Y or N Determination:
~Q. ~t Size: ACT. Lot Size: ~Q. Lot Cov.
~Q. Front ACT Front ~Q Side~ ACT. Sid~-- ~Q. Rear
~Q. Height~ ~ ACT Height ~,~_ ' ~
Vaterh'ou~ 5' or N0 u
ryes, water I~ocly ..... Pauel~ ..... Flood Zone: _ .. 13ulld~ead/Bluff Dis(ance:
,DDIT[OINAL A['PI>,O VA[,S ILEQUIIMSD
uffolkC{,uu(x Ile:~Hh: '~' ,,~ Iq [1 )'es,~lhxlll
, Inf0:_
ACT. Lot C0v.
_ PROP. Rear
ou(hohl 'l*luslens: '( ,,i t~ [~ah' '
:0uIhold ZB.\: h' ol /'l Da{e: /r
:outhohl Plauning: '/<n Iq- Date: / /
l)ermi( H: No[ts:
Pe~ mi( #: No(e,s:
?own Landmarlc C of A: T ol N DTE: / /
*NTS ('?ODE Compliauce (page 2): Y o~ N
(;alculatlol:
I [Jll{Ik/J Fee 3, /~.
t Additional Fee ( ): $
NEW YORK STATE CODE COMPLIANCE CHECKLIST
CLIMATIC/GEOG~HIC DESIGN CK][TERIA
Ground Snow Load: 45
Weathering: Severe Frost Depth: 36"
Design Temp: Il . [ce Shield Underlay: YE8
USE/OCCUPANCY CLASSI~'ICATION:
· HEIGI~T/FI[Pd3 AREA:
TYPE OF CONSTRUCTION:
DESIGN CR[TEPO~'~: ENGINEEP~D/PRESCI~PTIVE
Fi J LL, FPoSdv~IN G D ES IGN ELEMENTS: Y/N
HEADERS: Y/N WALL STUDS: Y/N
CE[J~[NG JOISTS Y£I~ FLOOR ,r(}fS'l'Y
LUh{I/ER SPEC/I~S AND G[C&DE: Y/N
DESIGN LOAD CALC~ILATIONS: Y/N
V,'I~qDOW AFrD k~-~.)k SCHEDLfLE
EGNlgSS 5~ S.F.: YIN
~IOHT 85;: Y/N
5~NT 4%:
NA[L~G/CONSTNUCTION SCHEDULE
PLIlI,ABBqG I~.ISI}R D[A(5[L~'vl
Wind Speed: 12,0MPI{ Se~lsmic Design Category: B _,
Termite: M~EI Decay: S-M
1t'1o o d Hazards:
I,', ,10 I: ILA I?TE1 tS:
I'.(). Box 1179
Soulh(~ld. Nh' 11!~71-09,39
Telephone (631) 76,3-1802
Fax (631) 76,3-9302
B! ~ILI)IN(; I)EI'AI/TMENT
TOWN OF SOUTHOLD
September 21, 2010
Jack Thilberg
1565 Jacobs Lane
Southold, New York 11971
TO WHOM IT MAY CONCERN:
The following items are needed to complete your Certificate of Occupancy:
Application of Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate.
A fee of $25.00.
Final Health Department approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
__ Trustees Certificate of Compliance. (Town Trustees #765-1892)
__ Final Planning Board approval.
__ Final Fire Inspection from Fire Marshal.
__ Final Inspection from the Building Dept.
__ Final Landmark Preservation approval.
Building Permit: 34369-Z accessory garage
' SINGLE FAMILY DWELLING ONlY ~ '-' ' '~ ' ''~ ~: "
The Sewage disposal and water supply facilities for this
location have been inspected by this Department and/re'
other les nd fau to fi~
Chief o//Bureau of Was'eewe~'J~alla~me~ --
CERTIFIED TO,
FIRST AMERICAN TITLE INSURANE
COMPANY OF NEVI YORK
R(V£RHEAD SA VINGS BANK
~,~4CK H. THILBERG ·
~,,AREN M. THILBERG
B~J-~ # 87S0136
SURVEY OF
LOT 3
MAp OF
CROWLEY ESTATES
A'T BA YVIEW '
TOWN OF SOUTHOLD
SUFFOLK COUNTY, N Y.
1000- 79- 06 -_ 4.3
Scale 1"= 50'
Oct. 15, 1987
Dec. 18. '1987(under const.)
April 14, 1988 (final)
~I090 30 SC M2¥ 0223003 ac44 290900 4 o o
t
Robbins Engineering, Inc./Online Plus' APPROX. TRUSS WEIGHT: 324.9 LBS
B -I 0.29 2377 C
I -C 0.47 3012 T
G -C 0.11 707 T
C -F 0.47 3012 T
F -D 0.29 2377 C
Online Plus -- Version 20.0.010
R~N DATE: 02-FEB-07
CSI -Size ..... Lumber ....
TC 0.97 2x10 SP-2401 TL Dell -0.53" in G -F L/656
BC 0.86 2x 8 SP-2401 LL Dell -0.47" in G -F L/741
WB 0.47 2x 4 SP-#i Shear // Grain in B -C 0.78
Plates for each ply each face.
Brace truss as follows: PLATING CONFORMS TO TPI.
C.C. From To REPORTS: ICC-ES ER-2929
TC 2- 0- 0 0- 0- 0 29- 9- 0 Plate - MN20 20 Ga, Gross Area
BC 7- 6- 0 0- 0- 0 29- 9- 0 Plate - ~18 20 Ga, Gross Area
Plate - MTSH 20 Ga, Gross Area
Loading Live Dead (psf) Plate - TL16 20 Ga, Gross Area
TC 47.0 4.0 Jt T!rpe Plt Size X ¥ JSI
BC 0.0 2.0 A ~20 11.2x16.215.0 3.0 0.98
Total 47.0 6.0 53.0 A MN18 8.8x20.025.3 4.4 0.92
Spacing 108.0" B# MN20 3.8x 5.0 Ctr Ctr 0.96
Lumber Duration Factor 1.15 C ~20 11.2x16.2 Ctr Ctr 0.98
Plate Duration Factor 1.15 D b~20 3.8x 5.0 Ctr Ctr 0.94
TC Fb=l.00 Fc=l.00 Ft=l.00 E ~20 11.2x16.2-7.7 3.0 0.98
BC Fb=l.00 FC=i.00 Ft=l.00 E ~N18 8.8x20.0-7.7 4.4 0.92
I MN20 7.5x10.0 1.3 0.6 0.94
Jt React Uplft Size Req'd G# MTSH 7.0x16.0 Ctr Ctr 0.71
Lbs Lbs In-Sx In-Sx F MN20 7.5x10.0-1.3 0.6 0.94
A 7095 0 5- 8 5-14 **
E 7095 0 5- 8 5-14 **
# = Plate Monitor used
Membr CSI P Lbs Axl-CSI-Bnd REFER TO ROBBINS ENG. GENERAL
.......... Top Chords .......... NOTES AND SYMBOLS SHEET FOR
A -B 0.59 13243 C 0.25 0.34
B -C 0.97 12418 C 0.21 0.76
C -D 0.97 12418 C 0.21 0.76
D -E 0.59 13243 C 0.25 0.34
........ Bottom Chords .........
A -I 0.86 12449 T 0.51 0.35
I -G 0.74 9407 T 0.39 0.35
G -F 0.74 9407 T 0.39 0.35
F -E 0.86 12449 T 0.51 0.35
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
Morton Buildings, Inc.
Analysis Conforms To:
ANSI/TPI 95 & 02
Run vertical thru bottom chord
Joint G
............. Webs ............. Prevent truss rotation at all
bearing locations.
Truss is designed for no
ceiling load.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Max comp. force 13243 Lbs
Quality Control Factor 1.00
128.0826 R2
Quan Type Span P1-H1 Left OH Right OH Engineering
I PORCH 81008 4 0 0
HO 1-15
D
ALL PLATES ~ LOCK20
Scale: 0.553" = 1'
Robbins Engineering, Inc./online PlusTM APPROX. TRUSS WEIGHT: 67.3 LBS
Online Plus -- Version 20.0.025
RUN DATE: 19-NOV-08
CSI -Size ..... Lumber ....
TC 0.57 2x10 SP-#1
BC 0.28 2x 6 SP-#1
WB 0.09 2x 4 SP-#1
Brace truss as follows:
O. C. From To
TC 4- 0- 0 0- 0- 0 8-10- 8
BC 10- 0- 0 0- 0- 0 8-10- 8
Loading Live Dead (psf)
TC 20.0 6.0
BC 0.0 2.0
Total 20.0 8.0 28.0
Spacing 89.5"
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
TC Fb=l.00 Fc=l.00 Ftc1.00
BC Fb=l.00 Fc~l.00 Ft=l.00
C 1061 39
Load Case # I Standard Loading
Lumber Duration Factor 1.15
Plate Duration Factor 1.15
plf - Live Dead From To
TC V 149 45 -1.1' 7.7'
BC V 0 15 -1.1' 7.7'
TC V 0 0 3.9'
155 0 7.7'
Hz = 154
5-8 1- 8
Hz = 498
Membr CSI P Lbs Axl-CSI-Bnd
.......... Top Chords ..........
D -B 0.57 215 C 0.00 0.57
OH Loading
Soffit psf 2.0
Provide connection to bearing
for 498 Lbs Horiz Reaction
Truss is designed for no
ceiling load.
Wind Loads - User Specified
........ Bottom Chords ......... Truss is designed as a Main
D -C 0.28 374 T 0.00 0.28
............. Webs .............
C -B 0.09 956 C WindLd
TL Defl -0.07" in D -C L/999
LL Defl -0.05" in D -C L/999
Shear // Grain in D -B 0.46
Plates for each ply each face.
PLATING CONFORMS TO TPi
(SBCCI 72145}
P~ATE VALUES MAY BE VERIFIED
WITH ROBBINS ENGINEERING.
GRIP BASED ON SPF/SYP LUMBER U
GROSS AREA TEST METHOD.
Plate - LOCK 20 Ga, Gross Area
Plate - RHS 20 Ga, Gross Area
Jt Type Plt Size X ¥ JSI
D LOCK 5.0x 5.0 Ctr Ctr 0.92
B LOCK 3.0x 4.0 Ctr Ctr 0.61
C LOCK 1.0x 4.0 Ctr Ctr 0.75
REFER TO ROBBINS ENG. GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Plus 3 Wind Load Case(s) NOTES:
Trusses Manufactured by:
Jt React Uplft Size Req'd Robbins Engineering
Lbs Lbs In-Sx In-Sx Analysis Conforms To:
D 854 0 5- 8 1- 8 ANSI/TPI 95 & 02
Wind-Force Resistance System.
Wind Speed: 100 mph
Mean Roof Height: 25-0
Exposure Category: C
Occupancy Factor : 1.00
Building Ty~e: Enclosed
TC Dead Load: 10.0 psf
BC Dead Load: 10.0 psf
Max comp. force 956 Lbs
Quality Control Factor 1.25
FOR: JACK & KAREN THILBERG
SOUTHOLD, NY
BUILDING USE: FARM MACHINE STORAGE
JOB # 128-0826
BUILDING DESCRIPTION:
WIDTH .................................. BW := 30.fl
LENGTH .................................. BL:= $4.fi
SIDE OVERHANG WIDTH ......... SOW := I.fl
END OVERHANG WIDTH ..........
GRADE TO HEEL HEIGHT ........ HH:= 14. fi
ROOF SLOPE .......................... AS := 4/12
BAY SPACING ......................... BS := ?.5.ft
END BAY SPACING .................. EBS := 7,5.ft
BUILDING VOLUME .................. ~..57~- 2~.,~
PEAKHEIGHT ..........................
DESIGN LOADS:
WIND SPEED ............................. V~ := 120 mph
EXPOSURE CATEGORY ............. EC := "C"
ENCLOSURE CLASSIFICATION.,. gnC := "ENCLOSED"
WIND IMPORTANCE FACTOR ..... Iw := 0.7?
GROUND SNOW LOAD ............. ps :: 20.psf
SNOW EXPOSURE FACTOR .... SEF := "PARTIALLY"
SNOW IMPORTANCE FACTOR.. 1.:= 0.8
THERMAL FACTOR .................. C, :- 1.2
ROOF SURFACE ..................... Surface := "SLIPPERY"
REFERENCED STANDARDS:
SLOPED ROOF SNOW LOAD
Ps := 0'7'Ce'ls'Pg'Ct'Cs
Ps = 12.6'psf
MINIMUM ROOF LIVE LOAD
Lr:= 20.ps£.Ri.R2
Lr- 19.5.ps£
DESIGN LIVE LOAD ................... LL := 20psf
DEAD LOAD ............................... DL := 4.psf
CEILING LOAD ........................... CL :- 0.psf
ASCE 7-02
NYBC 2007
NDS 2001
Page 1 of 19
SEISMIC DESIGN:
Seismic UseOroup := "1"
Site Class :- "D"
Spectral response acceleration @ short periods (Ss):
Spectral response acceleration @ 1-second periods (S1):
Site coefficient (fa):
Site coefficient (fy):
Sins := Fa-Ss Sins - 0.392
Ss: 0.245
Si: 0.074
Fa 1.6
Fv 2.4
Stol := Fv.SI Stol = 0.178
SDS := (~)'Sms SDS= 0.261
2 S
SDI:= (~)' mi SDI=0'118
Seismic_Design_Category Ss = "B"
Seismic_Design_Category SI = "B"
Note: Most severe category governs; therefore
Seismic Design Category = "B"
DESIGN REQUIREMENTS FOR SEISMIC CATEGORY B
Buildin~Weight 24000.1b
Is building light-framed construction three stories or less in height?
Response modification factor (R): R := 7
SIMPLIFIED ANALYSIS PROCEDURE (SAP) FOR SEISMIC DESIGN OF BUILDINGS
SAP - "APPLICABLE"
1.2.SDs
R
V- 1062.607-1b
Since the Lateral Load from the Seismic Condition is much less than the Lateral
Load from the wind, the wind Icad design governs.
LFC31ess :- "YES"
Page 2 of 19
WIND CALCULATION:
W1
IEH= 15.5ft = ~ Wt.
WIND DESIGN COEFFICIENTS:
WIND DIRECTIONALITY FACTOR .................................................. K~ :- 0.85
3-SECOND GUST SPEED POWER LAW EXPONENT ..................... c~ = 9.5
NOMINAL HEIGHT OF THE ATMOSPHERIC BOUNDARY LAYER .... zo = ':)00 ~
MEAN ROOF HEIGHT ................................................................... H: 18.027.~t
HEIGHT ABOVE GROUND LEVEL (ASCE minimum) ...................... z = 18.027
VELOCITY PRESSURE EXPOSURE COEFFICIENT ........................ Kz: 0.88
VELOCITY PRESSURE,,. q := 0,0b256.Kz.K~.V3$2.1~¢psf q: 21Pg, psf
EDGE STRIP WIDTH ....... ESW = 3 ft
END ZONE WIDTH ......... EZW: 6 fi:
INTERNAL PRESSURE COEFFICIENTS:
GCpilN = -0.] 8
GCpi OUT = 0.18
EXTERNAL PRESSURE COEFFICIENTS - CASE A - TRANSVERSE LOADING:
END ZONES
GCp£A.i E 0.78
GCp£A 2u = -I .07
GCpf:A 3E = 0.673
GCpl'^4E- 0.618
GCp£A 5E - 0.78
GCpfA 61 = -0.618
INTERIOR ZONES
GCp£A 1 = 0.516
GCp£A 2 - -0.69
GCp£A 3 - -0.469
GCp£A 4 - -0.415
GCpltA 5 = 0.45
GCpl A 6 -0.45
Page 3 of 19
MWFRS DESIGN PRESSURES - CASE A - TRANSVERSE LOADING:
END ZONES
PA 1[ I :: q'(GCpl:^ Ir GCpi IN)
P^2EI := q.(OCpf^ 2l: - GCpi IN)
P^3FI :-- q'(GCpl:A 3l - GCpilN)
PA4EI := q'(GCpI:A4E - GCpilN)
PA5EI := q'(GCpI~A 5E - GCpi IN)
PA6EI : q'(GCpI:A6E- GCpilN)
PA IE2 :: q'(GCpfA IE - GCpi OUT)
P^2E2: q'(GCpt:A2E- GCpiOUl)
PA3E2 := q'(GCpfA3E - GCpioUT)
PA4E2 := q'(GCpfAaE GCpioUT)
PASE2: q'(GCpfASE - GCpiOUT)
P^6E2 :: q'(GCpfA SE - GCpi OUT)
INTERIOR ZONES
PA I I := q'(GCpfA 1 - GCpiIN)
PA21 : q'(GCp[A2-GCpilN)
PA 3 1 := q'(OCpfA 3 GCpi IN)
PA4t : q'(GCpt:A4-GCpiIN)
PA5 I := q'(GCpfA 5 - GCpi.lN)
PA 6 I :: q'(OCpfA 6 GCpi IN)
PAl 2 := q'(GCpfA I GCpiOUT)
PA22 := q'(GCpfA2 - OCpi OUT)
PA 32 := q'(GCp[A 3 GCpi OUT)
PA.42 :: q'(GCpfA4 - (}Cpi OUT)
PA 5.2 := q'(GCp£A 5 - OCpi OUT)
PA.62 TM q'(GCpfA6 - OCpi OUI)
PA II t = 20.442'psf
PA 2E I : - 18.948.psf
PA 3E I -I 0.502.psf
P^ 4I~ I - -9.327.psf
P^.SE ~ - 20.442.psf
PA 6u I - -9.327. psf
PALE2 = 12.777.psf
P^ 2E 2 -- -26.612. psf
P^3E2 = -I8.166-psf
PA4E2 = 16.991.psf
PA 5E2 - 12.777.psf
PA 6E2: -I 6.991 .psf
PA I I = 14.827.psf
PA 2 I -lO.858.psf
PA 3 I = -6.143.psf
PA41 -5.011-psf
PA S 1 = -5.748. psf
P^61= 5.748.psf
PA I 2 = 7.163.psf
PA22 = -18.522.psf
PA32 - 13.807.psf
PA42 = 12.676.psf
PAS2 = 13.412.psf
PA62 = -13.412.psf
Page 4 of 19
EXTERNAL PRESSURE COEFFICIENTS - COMPONENTS AND CLADDING:
GCpl = 0,9
GCp2 = 1.7
GCp3 = -2.6
GCp4 :- - ]. I
GCp5 :- - 1.4
COMPONENTS AND CLADDING DESIGN PRESSURES:
PCCI I:= q'(GCpl - GCpiIN)
PCC2.1 := q'(GCp2- GCpi
PCC3 I := q'(GCp3 GCpi IN)
PCC4 I := q'(GCp4 - GCpi
PCCSI: q'(GCp5-GCpilN)
PCCII = -I 5.328'psf
PCC2 I = -32.36. psf
PCC3~ = -51.521,psf
PCC41 = -I 9.586'psf
PCC5~ - -25.973.psf
PCCI2 := q'(GCpl GCpi OUT)
PCC22: q'(GCp2 - GCpiOUT)
PCC32 := q'(GCp3 GCpi OUT)
PCC42:= q'(GCp4 GCpi OUT)
PCC52 := q'(GCp5 GCpi OUT)
PCCI 2 = -22.993.psf
PCC22 -- 40.024.psf
PCC32 - -59.185,psf
PCC42 - -27.251 .psf
PCC52 = -33.637.psf
Page 5 of 19
MAIN WINDFORCE-RESISTING SYSTEM:
END ZONE HORIZONTAL LOADS
PA E~all = 29.768-psf
PA Emot = O'psf
INTERIOR ZONE HORIZONTAL LOADS
PA wall = 19.838.psf
pA roof= O.psf
DIAPHRAGM PROPERTIES:
ROOF Safety Factor := 2,5 Duration Factor := 1.33
Roof Material: 0.019 Hi-Rib Steel Ultimate_Shear := 177.plf
/Ultimate Shear).Duration
Roof Allowable Shear :: ~ Safety Factor J Factor
Roof Allowable Shear = 94.164.plf
Roof Material: 0.019 Hi-Rib Steel (Lap Stitch) Ultimate Shear :: 275.plf
{U t mate Shear~
Roo~Allowable Shearstitch := |-~ |.Duration Factor
~ Safety_Factor j -
Roo~Al[owable_Shearstitch = 146.3.plf
WALL Safety Factor := 2.5 Duration Factor := 1.33
Wall Material: 0.019 Hi-Rib Steel Ultimate Shear := 177,plf
(Ultimate She /.Duration
Wall_Allowable_Shear := ~ Safety Factor j Factor
Wall Allowable_Shear: 94.164.plf
Wall Material: 7/16" OSB Shear wall with 2"x4" (SPF) Horizontal nailers at 24" o.c.
2"x6" vertical blocking at columns
Nailed with 1-3/4" R,S, coil nails
Nailed at 4" o.c. along edges and
at 6" o.c. along intermediat framing
Table 2306,4,1
Wall Allowable_ShearosB :- 1.4.0.92.300.plf - 386.4-plf
Page 6 of 19
END ZONE LOADING TO ROOF DIAPHRAGM:
BW
O~E walI - 173.327.plf
~JE.roof = 0.plf
EL = 173.327.plf
INTERIOR ZONE LOADING TO ROOF DIAPHRAGM:
COl wall := '375'EH'pA xxa]l
BW
~Ui roof := ~
IL: LOi walI + (0] toof
t~l walI = 115.508.plf
OJl roof = 0'p[f
IL = l15.508'p[f
180
164
148
132
116
100
WIND LOADING DIAGRAM
EZW BL
20 40
Building Length
3446.4
2133.!
820.~
- 492.~
- 1805.~
- 3118,
SHEAR DIAGRAM
Building Length
SHEAR TO ENDWALL
SHEAR TO END I = 3446,3581bf
Page 7 of 19
ROOF:
RW :- BW + 2.SOW RW = 32fl
Allowable_Diaphragm Shear_Roofsmch :- Roof Allowable Shearstitch,RW
A[IowableDiapbragm_ShearRoofstitch = 4681.6
Allowable_Diaphragm Shear_Roof := Roof_AIIowable_Shear-RW
Allowable_Diaphragm ShearRoof = 3013.21bf
Required Roof_Reinforcing:-- SHEAR TO END_I Allowable_Diaphragm Shear Roof
Required_Roof Reinforcing = 433.11-1bf
Required_Root'Reinforcing
Reinforcing_Length 1 :=
EL
Reinforcing Length_l = 2.499ft
Actual Roof Reinforcing with Lap Stitching = 3 ft
END WALL:
SHEAR TO END 1 = 3446.1bf
Wall Allowable Shear: 94.164.plf
Available_Siding := 15.fl
Allowable_End Wall :: Available Siding. Wall_Allowable_Shear
Allowable End Wall = 1412.5.1bf
Wall Allowable ShearosB = 386.4.plf
Required_Shearwall Length :=
(SHEAR_TO END I Allowable End_Wall)
Wall AIIowable_ShearosB
Required_Shear,vail_Length = 5.264
Actual Shearwall Length = 6.7 ft
Page 8 of 19
SIDE WALL COLUMN DESIGN CRITERIA - END ZONE:
Column analysis with Roof Diaphragm; therefore, columns are
considered as propped cantilevers.
Columns in Tension - Controling Load Case
Axial_Deado (~ := .6(DL + CL).Bs.(B2W +
Axial Deado6:288.[bf
w:= pA iEi.BS Ma:=
w: 15.~.M3.plf
Ma = 4620.045-fllb
Axial Wind:= P^2Ei.BS.(BW?~- + SOW
Axial Wind = -2273.72.1bf
PN:= Axial Deado6+ Axial Wind
PN = -1985.72.1bf
Colunm_Size = "3 - 2x6 Lmninated Column"
A: 24.75-in2
S = 22.69. in3
Fc = 1750. psi
INTERACTION VALUE :=
Id = 30.55
Fb - 1900.psi
F, = 900.psi
At 24.75.in-
M,, x = 1.5.r
INTERACTION_VALUE = 0.86
SPLICE CHECK: LOWEST CUTOFF X = 1.5 fi
A~ = 24.75.in2 Fbs = 1650-psi
Ss = 15.12. in3 Ft. = 900.psi
Fcs = 17$0-psi Als = 16'5'in2
Mb = -2560.86.fllb
INTERACTiON_VALUE := / I PNI
Ats. Fts. l.6
INTERACTION. VALUE = 0.853
Page 9 of 19
TRUSS TO COLUMN CONNECTION:
ROOF LOAD
Truss is saddled between outside members of column and bearing on center member with
(2) 1/2" Diameter through Machine Bolts and (4) 20d R.S. Nails
Connector Load = 2189.6.1bf
P: Total Axial
Center_Member_Is- "2x6" Areacentermember- 8.25-sqin
UPL IF T
Bearing_Stress :=
(P Connector_Load)
Bearing_Stress = 83.685.psi
Connector_Load = 3046.4.1b
1
BDL = 480.1b
UPLIFT:= PA2E2' + SOW .(2.25ft) + PA22'
2
UPLIFT = 2513.866.1b
NET UPLIFT := UPLIFT - 0.6.BDL
NET UPLIFT = 2225.866.1b
+ SOW -(5.25fl)
2
SIDE WALL FOOTING:
Allowable Soil Bearing_Pressure:= 2000.psf
Footing Diameter:= 16. in
Footin~ Thickness = 8.in
· 2
Footing_Diameter .w
Areaact .
4
P
Areareqd :=
Allowable Soil_Bearing Pressure
Areaact = 1.3961~2
Areareqd = 1.02 f~2
Page 10 of 19
SIDE WALL EMBEDMENT - END ZONE:
Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor
To find required embedment depth, solve simultaneous equations below
Initial try:
d := 4.Pt
hP := Ma
Given
4.25-hP
S3,B
S3 := 1600.psf
B = 0.592fi
COLUMN EMBEDMENT DEPTH: d =4.364fi
S~ = 1741.351.psf Soil Classification #4
Actual Column Embedment depth: d := 4fl + 8in = 4.667 ft
Horizontal Shear at Grade: 3/16"X3/4"X30" "~ /
SHEAR = ]487.774.1b£ HR. Flat Steel ~
Allowable Shear resisted by two Base Anchor Straps: [~ 0/I 77" x 2.25"
Consider 22,000 psi steel % Stainless Stee
Steel Area = 0.105 in2 ", Anchor Nails
~ 3 Member Column
Therefore Allowable Shear = 4620 lb
Allowable Shear resisted by 8 - Stainless Steel Nails:
= 8(216)(1.6) = 2764 lb
Allowable Withdrawal of Strap in Concrete:
= (1.0 in)(0 75 in)(2)(2000 psi) = 3000 lb
Page 11 of 19
SIDE WALL FOOTING UPLIFT - END ZONE:
[Bw )
UPLIFT:= PA2E2' + SOW .(2.25ft) +
2
UPLIFT: 2513.866 lb
(Bw }
PA22' + SOW .(5.25ft)
2
d : 4.667fi
RI = 8-in
If, :: d.tan(.5236) + RI
R3 :- R2 - RI
Soil Volume Above Footing
Ri
V := -I .,rr.d. + R2~+ RI.R
3
V = 68.325 ft3
CORHER WITH (3)
~AiNL~ NAI~, {12TO~AL NAiU;
PER COLIJM N~
aDOI11OflA[ R~D'~ ,M.X T9 TOP OF 21~M STIU
Total Soil Weiqht
Allowable Soil Weight := 100.pcf
TSW := V.AIIowable_Soil_Wcight
TSW = 6832.528.1b
Buildinq Dead Load
BDL = 480.1b
Total Weiqht on Footinq
TWF := TSW + BDL
TWF: 7312.528.1b
COLUMN TO FOOTING CONNECTION:
NET UPLIFT := UPLIFT - (0.6.BDL)
NET UPLIFT = 2225.866.1b
No, of Nails Required to Resist Uplift = NAILS = l I
Page 12 of 19
PURLINS:
Purlia Size = "2 x 4 (No. 2 SPF)" @ 23" o.c.
Fb = 875.psi Creep_Factor := Cr = 1.15
S: 3.063.in3 Roof sheeting load .......
1: 5.359. in4 Purlin dead load ..........
E - 1400000.psi Span Factorstrength - 0.107
Total Loadstrengfl~ := (LL + SL + PL)
Total Loadstrength - 22-psf
Spacingpurlms := 24.in
I(T°tal- L°adstren"th'SpacingPur'ins'BS2)l-8
Sr¢q := - Sreq = 2.139. in3
Fb-Cr'Cd-CF
SL:= 0.9. psf Cd= 1.15
PL = I.I.psf CF = 1.5
Span Factordeflection = 0.007
PURLIN TO TRUSS CONNECTION (Uplift):
Interior Strip: Headlok 0.19"x6.0" Flathead Laq Screw
Purlin ToTrtlSSscrew :: 627,ibf
Required_Strengthinl := -PccI 2'BS'Spacingpurlins = 344,89 lb
Edqe Strip: Headlok 0.19"x6.0" Flathead Laq Screw
Purlin To TrusSscre~ := 627.1bf
Required_Strengthedge := PCC22'BS'Spacingpudins = 600.364 lb
ROOF SHEETING TO (NO. 2 SPF) PURLIN CONNECTION:
9x2" Stainless steel Rubber Washer Panhead Internal Drive Screws at every Hi-Rib (1'0" o.c.)
Screw_Spacing :- Iff.
Strengthact :- 2911b
Interior Strip:
Required Strength Sheetingim :- -PccI 2'Spacingpurlms'Screw_Spacing - 45.985 lb
Edqe Strip
Required_Strength_Sheetinginl :-- -Pcc22'Spacingpurlins'Screw Spacing 80.0491b
Page 13 of 19
SIDE WALL NAILERS:
Nailer Size = "2 x 6 (2100 MSR)" ~ 36" o.c. Max
F,, = 2100.psi ('~: I ~
Total_Load := PCC42 ]
Total Load= 27.251.psf [ I ! [
Spacin~,¥ulcrs := 36.in
Sreq :=
Fb'Cr'Cd'CF'C fu
Sreq = 1.785.in3
2x6 NAILER TO COLUMN CONNECTION
(Withdrawl):
(4) 0.177"x4" (20d) R.S. Nails
W:: 54./Ivbb).2.5-in.l.6 = 2161b
Nails :- 4
Withdrawlact: W.Nails Withdrawlact = 864.1bf
Required Strength := 1.25-BS--Pcc42. Spacingnailers
Required_Strength - 766.423 lb
WALL SHEETING TO NAILER CONNECTION:
9x2" Stainless steel Rubber Washer
Panhead Internal Drive Screws at every
Hi-Rib (1'0" o.c.)
Screw_Spacing := Iff
Strengthact := 291 lb
Required Strengthsheeting := Spacingnailers. Screw Spacing.(-Pcc42)
Required Strengthsheetmg = 81.7521b
Page 14 of 19
PORCH DESCRIPTION:
PORCH DESIGN LOADS:
PORCH WIDTH ........................ PW :=
PORCH LENGTH ..................... PL:= 14-~t + Ilin
PORCH OVERHANG POW := I-fi
GRADE TO HEEL HEIGHT ........ HH :- 8['[ + 4in
ROOF SLOPE .......................... RS:- 4/12
PORCH BAY SPACING ............ PBS := 7.5.fl
END BAY SPACING .................. EBS:
GROUND SNOW LOAD .............
SNOW EXPOSURE FACTOR ....
SNOW IMPORTANCE FACTOR..
THERMAL FACTOR ..................
ROOF SURFACE .....................
pg := 20.psf
SEF := "PARTIALLY"
L:= 0.8
C~ := 1.2
Surface := "SLIPPERY"
SLOPED ROOF SNOW LOAD
Ps: 0'7'Cc'ls'Pg'Ct'Cs
Ps = 12.6.psf
MINIMUM ROOF LIVE LOAD
L~:- 20.psf. Ri.R2
Lr = 20.psf
DESIGN LIVE LOAD ................... PLL = 20.psf
DEAD LOAD ............................. PDL: 6.psf
CEILING LOAD ........................... PCL := 2.psf
Page 15 of 19
Snow Drift:
Pg := 20.psf Ps TM 12.6.psf Iu := 32,fl
Roof'Height difference:= 3.33.fi
hb = 0.759. ft "f: 16.6.pcf hd: 1.695-ft W = 4.997.1l Pmax = 40.736.psf
1o(
_~ 6(
~ 4(
Slidinq Snow
slope = 4.15. '~
fl
2 4 6 8
Width of Drift (ft)
Pr := 20psf
Sliding :=
15fi
Sliding: 8.533,psf
Drift Load Condition Controls:
Porch Pulin Live Load ........ PLL := Pma×
Ptolal := Ps + Sliding = 28.533 psf
Page 16of 19
PORCH FRAME:
Check top chord as a rafter:
2"x10" Rafter, NO.1 SYP
Note: Unsupported Length =
lb:: 1300psi
i.:= 7fi + 8.5in
Sact := 21.39in'~
Load := PLL.PBS
Load = 305.523.elf
Load. L2
Mrnax :=
8
Mrnax = 2269.208'fllb
Srcq' fb.l.15 Srcq: 18,214.inJ
PORCH PURLINS:
Purhn S~ze= ~x4(2100MSR) @ 3 o.c. Max
Fb 2100-psi
S 3.063-in3
I 5.359. in4
E: 1800000.psi
Creep Factor :- 1.5
Roof sheeting load ......
Purlin dead load ..........
Span Factorstrength := .125
SL :: 4.9. psf
PL -- I.l.psf
Span Factord¢flection := .003
Total Loadstrength := (PLL + SL + PL)
Total_Loadstrength = 46.736.psf
Spacing := 23-in
[_(Total Loadstrel~th. Spacing, BS2~I
Sreq :=
Fb'Cr'Cd'CF
PORCH COLUMN:
Sreq = 2.72 l- in3
Check - Full LL, Full DL
Total Axial Porch: 114421b
Total Axial Porch = 1144.2.1bf
fTotal Axial Porch~
INTERACTION VALUE := [ ~ [
[, A'Flc'I.15 j
INTERACTION VALUE 0.113
Page 17 of 19
PORCH FOOTING:
Allowable Soil_Bearing_Pressure := 2000.psf
P := Total_Axial Porch [ 144.2.1b
Footing_Diametel :- 16-in
Footina Thickness 8.in
2
Footing_Diameter .~
mreaact :=
4
P
Areareqd := Allowable Soil Bearing Pressure
Areaact = 1.396 ft2
?
AreareqcI = 0.572 ft-
PORCH FRAME TO PORCH COLUMN CONNECTION:
UPLIFT
ConnectorLoad - 2809.6.1b
pDL := (PDL + PCL),PBS'[~- + POW
pDL = 300.lb
NET UPLIFT := UPLIFT - 0.6.pDL
NET UPLIFT = 817.946.1b
PW
UPLIFT:= PA 2E2' +
2
UPLIFT = 997.946'1b
POW).PBS
PORCH FRAME TO HEADER CONNECTION:
NET_UPLIFT = 817.946 lb
Loadhcader :- I 135.031b
Connection is made with USP JH20 Joist Hanger and 1 pair framing clips
USP JH20 Joist Hanger: 1285 lb
Framing clips: 1170 lb
HEADER CONNECTION AT BUILDING:
2"x10" Header, No. 1SYP,
Loadheader
Nails Required.
1.15.2011b
4.91 (6) 20d R.S. Nails at connection
Page 18 of 19
BUILDING FOOTING AT PORCH HEADER:
Allowable_Soil Bearing Pressure:= 2000.psf
P: Total Axial Porch + Total Axial = 4024.2.1b
Footing Diameter := 24.in
Footinc_, Thickness = 10.in
Footing Diam,eter-.'rr
AreaacI:
4
P
Areareqd :=
Allowable Soil Bearing_Pressure
Total Axial = 28801b
Areaact = 3.142 ft-
Areareqd = 2.012 ft2
Page 19 of 19
OMPUTERIZED
TRUCTURAL
i ESI(3N, INC.
· CONSULTING ENGINEERS ·
Donald R. Buettner PhD_ P.E.
LeRoy A. Lutz. Ph.D.P.E
Charles E. Manske. PE.
Richard J. Schleis. PE.
James M Fisher. Ph.D. PE
Roger J. Becket P.E.
CraiciL. Beecher P.E.
Curtis B. Miller PE.
Michael A. West. P.E.
Daniel G. Horn. P.E.
Thomas W. Whittow. PE.
Robert E. Abendroth
October 6, 1980
Mr. Don Ferguson
Morton Buildings, Inc.
252 West Adams Street
Morton, Illinois 61550
Subject: Diaphragm Tests of
28 Gage Sheeting
Dear Mr. Ferguson:
This letter will serve as our report to you on the results
of the diaphragm tests conducted on the 28 gage sheeting mentioned
above. The tests were conducted in accordance with the criteria
established by the American Iron and Steel Institute Publication
"Design of Light Gage Steel Diaphragms". Two identical tests
were conducted per the criteria mentioned above. The tests were
conducted using a cantilever frame 15'-0" by 18'-0" at the
University of Wisconsin - Milwaukee. The purlins, connections
and sheeting were tested in a manner to represent a building
configuration as shown on the attached sheets, "Morton Buildings -
800 Series Construction Manual" - dated February 20, 1980, pages
39, 40, 69, 76, 77.
The results of the tests are as follows:
Copies
Ultimate Shear = 177 ~/'
Shear Stiffness = 3358 9/"
of the original data sheets and work sheets are attached.
Sincerely yours,
COMPUTERIZED STRUCTURAL
DESIGN, INC. ~
Jv~cee%Mr;s~id~hn~r, Ph.D., P.E.
JFIF/jah
Encl.
5678 West Brown Deer Road · Milwaukee, Wisconsin 53223 · Phone 414-354-0150
>~rk the purlin spacing on %he trusses while :he7 are on :he ground.
· spa:lng is no.--r, al!y e not, hal 20" o.c. 5~e-;er, ~acch /or special purlin
on the building plans. On s:~ndard buildings, purlins should be spaced according
co =he :Woia below cc obtain evenly spaced purlins. Purlin marking =usc scare ac
che boc=o~ ~nd proceed ~o the top and any odd spacing will then be ac =he cop. lc
is suggested thac you make a marking guide ou: of a piece of SB or SF flashinE as
shc~n in =he ii!us=racion below. These can be saved and reused. The ~op
purlins are ~o be huuced end ~o end &" beio~ uhe peak and spliced ~ich an 18"
as sho%~ beio%'. Under no circuz~cances ~i!t nails be permitted in the =russ as
purlin locacinz ~uidas.
7'6" OALESS
*22"
20
= co ~c %he o%ner _:~2_ :--nS ;:crk -_'rcm %he save ~¢ %?.e ..-:-%~:.
*Purli~ soacin~s are altered ~nen the 72' wide buildings have an overhang -
see :he overhang sectign for proper spacings.
~--'--- cgg -rpaci--~ sncu'-i acc"--- e% %1-.5~ location
Peak purlins zu~[ be spliced wi:h an 18" block below [he purlins.
detzi! -'- sho%-n below. Nail :he block :o :he nruss wi:h a 60d R.S. nail. Nail nh-:
purlins to :he block %-i:h 2-16d nails a% each connection. Make sure ~he peak
purlins are both seuuing on the truss.
?Jails
7=-~: Furli.n ..'cinz_e.=~l
BUILDII [ $
60D R.S.
Nail
800 SERIES CONSTRUCTION PROCEDURE MANUAL
FEB. 20, 1980 PAGE. 29
Tape 'the ienEth of the building at the peak to be sure it is the sa~e
length as the huildin~ is at the beveled purlin. Adjust if necessary.
~%~n al! the trusses are se: and before the purlins are placed,
end rafters should be straighcened. ~eu this is done the purlins are Then
placed accordTnE to the plans. Be abselute!y sure that no purlins are spli~
when nailed to the end Truss. The purlin connectioz to the end rafter must
be pre-drilled to accomodate one 60d K.S. nail. See the detail
2x4 PURLINS'~
PRE-~RILL HOLE
FOR 60D R.S. NA!LS
E~D TRUSS--
The 20' purlins are nailed at each end and at their centers ~ith a 60d
~.$. nail into ~he truss. They are se~ to ~he bottom of the mark ou ~he
truss. The 18' purlins are set to ~he top of the mark a~d nailed to the 20'
purlins ~i~h 2 - 16d nails at each end. See the detail below.
RAFTER
Afuer all roof purlins are in place, the height of the top of the 2x6
beveled purlin must be checked to make sure it is in line ~ith the tops of
the 2x4 roof purlins. This can be done by laying a short 2x4 on the roof and
checking the a!i~'nmenC of the 2x4 purlins to the 2x6 beveled purlin. If it
is off over ~" (~igh or lo~) the 2x6 beveled must be adjusted accordinglY-
Cut the side and end wall squares off a~ the same picch as the roof line.
BUILDIngS ~oo SERIES CONSTRUCTION PROCEDURE MANUAL FEB. 20, 19SO PAGE
40
203.03 RO0? P.'-_'{ELS
I. Roof panels must be applied in the following m~_uner:
If the building runs north ~nd sOUth, you must s~aru' a: the south end of
the buildin~ and wo%K ~owards ~he north end so tha~ :he ~aps face south.
if the building runs east ~d west, you m~ suar~ at ~he e~t end of
building and work towards ~he wes: because most s%o~s would come out of
the north or west. ~nis may eli~na~e some proble~ of p~e!s either
being blown off ~he roof, or blo~ loose on :he roof, or ~ven some roof
le~s in severe sso~s. No alte~ate applications are
~e roof steel should extend 2~" p~t ~he beveled purlin. ~nen positiou-
ina the roof suee! on the purlins place a 2~" N.W. nail ~der ~he roof
sheet wi~h the nail head at the end of the sheet. Push the sheet up towards
the pe~ ~it the .point of the nail hi~s the beveled purlin. This u~ll be
the proper amount the steel should extend into ~he gunter. ~In the case of
a side overhang use a 1~" R.S. nail ~c extend past ~he beveled f~cla.
2. Roof suee! is marked and rum similar to side steel, the first p~net should
be placed and squared up. A~ this mime, uhe gable ~ri~ should be placed
~nd nailed. ~e top purlin should be ~aoed ~d each 3' infer'al r~rked.
The roof p~el ts then placed lining up ~he botto~ with the sidewall
steel ~d the top with the mark. ~ne opposite side cam be r~ in the s~e
~ner. Place the SV5 ridgecap as you are ~ning the opposite side of
fne roof for a proper fit. (Refer to flashing section.) _You must keep
the ~-ribs on opposite sides of the ridge lined ~ so the SV5 ridgecap
will fit properly. Apply the roof p~e!s as show~ below. Note [ha~ the
roof panels are u~led complete as they are applied (1 n~l wherever a
Hi-rib crosses a purlin). ~ey are also nailed from a ca.et ru~er.
the top end bo%eom purlins
',~_th 2~'' N.W. nails.
Wrong
'au rib firs%.
~he c~her two ribs.
Space panels ~,,=:.,-o ~' -zr'~¢ CarDe+- runner
cn =!~-e "o'-'''~=': as e Fai!e. ~. ~ ~ ~ -,
. _..
[~ai! roof s=ee! ....
Drive nails per.
to roof panel.
980 P~E 69
Gable Trim:
G~ole :rim should be applied right after the firs: and after
:he las: roof sheet on earn side is applied. The bouto= end
is %o be :rimmed to hide the gutter as is sho~ in the fo!ic~'-
ing i!lus=ration. The top end of :he piece of 5~!6 running
to the peak should be left square cut on the first side than
is zxAu. The top end of the piece on the opposite side of :he
peak should be pinch cut and lapped over the other piece.
Nail the piece of SA16 at the peak and at the eave :o the pur-
lins and beveled board. Be sure that the ~" offset is on the
bottom side which is n~iled to the endwall. Have a crew mem~oer
sight the ed~e for in and out straightness and nail the SR!6
a: eve_~y lap in~o ~ne purlins. Then finish nailing ~he SR16
to eve~-y purlin. If you miss a purlin while ~ailing the SK!6,
lift the gable trim and apply white G.E. silicone sea!ant~over
:he hole in the roof steel.
Nail the side lip of the SP~6 to =he peak and eave through the
Hi-ribs into the end relier. Have a crew mercer sight fne 5.~2~6
for up and down straightness and nail the SR16 at every !ap.
Then finish nailing the SR16 at evenly Hi-rib.
-"SR16 GABLE TRIM
THIS PIECE
21
NOTE THAT THE GU~I~
IS COMPLETELY HiDBY
THE SR16 FROM THE EN~
. '"~k~..r~ BEND,.A 1" TAB DOWN TO CLOSE OFF
~....:..:--~ ~ ~THE ~ND OF THE SR16 GABLE TRIM
NOTCHING ~~ ~--~
ap~lie~ for the przper fi:. Ka~,,:he :enter ~irecc!7 above
fi: over
into the :op ~u_l_m. ~otch an~ benC :he en~ =~
5~6 gable ~r!m ~ sho~ in :he ii!us:re:ion below.
BEND l' TABS OVER
SR16
SRl= GaBL: IRIM~
M $igr. s:
,Sable Sie-n. s:
M sigu. s are for bu/iding idenuifica=iou and should be o!aced
where passersby and v!siuors will no:ice :hem =he most. :;ail
zs required to hold :hem in place.
Gable sigus are used =o ;-'-~- off the oeak join: of the S?.16
mud SV5 flashing. Use 2 pop .-~.ve:s or shee: ue~a! screws and
one nail ~o hold :he sig~ in place.
NOTE THAT THE END TABS ON THE SV5
POP RIVETS OR
e ~ ~'"~7'---........._..._..._......_~~H E B T METAL CREWS
-"-. //' I .....
eve~' pur!~n
Job No.
Job Name
Client
Page
Date
Engineer
of
HIL
5877 I..~'~ORATO~¥ No.
CH
FI~
REPORT
February 15, 1983
Witnessing of:
?erformed At:
Reported To:
Colunm Bending Tests
Morton Buildings, Inc.-
Morton, Illinois
Morton Buildings, Inc.
252 W. Adams Street
Morton, Illinois 61550
The following pa'ges dated 12/8/82 are the results of column bending
tests conducted for Morton Buildings, Inc., 252 W. Adams Street,
Morton, Illinois 61550.
These tests were conducted to make a comparison of the delative stiffness
in bending of columns fabricated from full length dimensional lumber to
those fabricated with spliced dimensional lumber as used in wood post-
frame construction. It was also to compare the ultimate bending stress of
the spliced columns to the allowable bending stress to determine a factor
of safety.
The columns tested consisted of nail laminating 3-2x6's together for one
series and 3-2xS's together for the other series. The lumber used in each
series was number i KD Southern Yellow Pine pressure treated in a 5% penta
~hlorophenol solution.
The columns were tested in a Tinius Olsen testing machine (s/n 34843). The
9' test span was loaded at points 2' from each end. The columns were
initially tacked together with 16d common nails. Dial gauge'indicators were
placed at.the load points and the center of the span. The deflections were
Pead' at 500 lb. intervals up to 8000 lbs,'for the 2 x 8 columns and 5000 lbs.
for the 2 x 6 columns. After unloading, the columns were taken apart, sawed,
and spliced together ~as showu in the attached drawing. The spliced columns
were nailed with an air compressor driven nailing gun in the unspliced area
with 4" ?aslode rink shank nails at 8" on center and staggered on each side
of the column. The splice area was nailed with 4" Bostitch smooth nails
following the nailing'schedule shown in the attached figure. The boards in
each column were numbered so that the boards in the spliced column were placed
in the same position as they were in the unspliced column.
PITTSBURGH TESTING LABORATORY
4418 '#~T ROOSEVELT ROAD
HILLSIDE. ILLINOIS 60162
CH 5877
Page 2
Thespliced ,cQlumns were then 'reteeted usingLthesame p~ocedure.
mentioned above The deflections of the spliced~columns were read up to
7000 lbs. and 4500 lbs. for the 2 x 8 and 2 x 6 columns respectively.
After removal of the gauges, the spliced columns were loaded to failure.
?.T.L. Representative: Joseph C. Torchia
PITTSBURGH TESTING LABORATORY
mj
lcc: Client
Attachments
David A. Dunn, Manager
Chicago District
18-200
NAILS
LONG SIOE
OF SPLICE -~
I
5-1/2"
5-1/2"
4 ADOITIONAL
20D NAILS BE-
LOW LOWEST
SPLICE CUT
k,,.,.. I z~'L~.°
UPP~
NOTE:
INTERMEDIATE
!CE CUT
,'IOTE:
NAILS OR 200 '
R.S. ANCHOR
~AILS.
S2LASHSDARD ~
, I
~ ,~IAI L-~
::1TE,:J4E-
5" ,'.[ATE
.'-.'lO
SR~:ICE ~
2 ADOITZQNAL
NAILS ~ELO~
LOWEST SPLICE
CUT
ITOTAL CF
SERIES CONSTRUCTION PROCEDURE MANUAL AUGUST 9, 1982 ~'.,}E: 21
PART 2-
TOP VIEW
PART 3
#100
KEEP THIS SIDE FLUSH
PART 4 IS NOT SHOWN ON
TOP & SIDE VIEWS FOR CLARITY.
SIDE VIEW
1. DIMENSION 'D' IS THE
LENGTH OF PART 4.
2. NAIL COLUMN 8" O.C. STAGGERED
NOTE:
~5/8" . '
/8;'NOTES:
DETAIL A
· MATERI.kL REOUI;IED I
PART DESCRIP-
NUMBER TION PART I PART 2 IPART 3 'PART 4 -
D402332 B332 8' 614332 6143322 6143323 6143324(1) 79.2
0402336 B~36 9' 6143361 614336~ 6143363!6143364{1) 88.9
0402340 B340 10' 614340 6143402 6143403 6143404(2) 98.5
~02344 B344 ll' 6143441 6143442 614344316143444{2) 108.2
,
0402348 B348 12' 614348' 6143482 6143483 6143484{2) 117.9
) 0402352 B352 13"6143521 6143522 614352316143524(3) 127.5
04023561 B356 14' 6143561 614356216143563(6143564{3)~135.5'
0402360 8360 )5' 6143601 6143602 6143603 6143604(3)i141.0
0402364 I'D364 16 6143641 6143642 614364~ 6143644(4) 150.7
0402368 B368 17' 6143681 6143682 61436~ 6143684{4) 160.4
'ARENTHESIS ~'NOTED 2x8 ~.U. STANDARD
I .,,.,,NOTED ORT ~
ON EACH SIDE O~ COLUMN WITH
PASLODE 4" NAILS.
KEEP COLUMN NAILS 10"
BELOW TOP OF CENTER MEMBER.
AN ADDITIONAL NAILER LOCATIO~
MUST BE MARKED A DISTANCE 'D'
FROM THE LAST NAILER BLOCK
AS SHOWN IN DETAIL A'.
PART 1, 1 - PA~T 2, i - PART 3, QTY, OF pART 4 IN.
0
Tr1P
16d NAILS
6" r,~ - 20
3'0''---~- ' 4'6" ~ 6'0"
FROHT & BACK
I I
9'0"
I--7]
BOTTOM
LUMBER DIMENSIONS.
BOARD
NUMBER 'WIDTH DEPTH
® ® ® 0 0 ®
19 1,548 1,543 1.570 1.554 5.500 ,I 5,485 5,490 ].492
.... 20 1.576 1,553 1,582 1,570 5,505 5,501 5.509
21 1.540 2,555 t,558 1,551 5,500 5.525 5,500 5.508.,
22 1,533 1,524 1,543 1,533 5.524 5,509 5,520 5,518
23 ~ 1.547 1.530 1.545 1.541 5.510 5.500 5.524 5.511
24 1.555 1.545 1.553 1.551 5.522 5.534 5.535 ~.530
25 1.545 1.550 1.550 1.548 5.505 5.504 5.512 ~.507
26 1.535 1.555 1.570 1.553 5.515 i.485 5.500 ~.500
27 : 1,545 1,525 1,560 1~543 5,505. 5,502 5,500 ~.502
28 1,538 1,525 1,563 1,542 5,508 5,507 5,518 5.511
29 1.568 1,524 1,538 1,543 ~,500 5,495 5,490 5,49~5.5
30 1.532 1,540 1,540 1,537' 5,502 5,500 5,505 5,502
31 ~ 1.560 1,560 1.563 1,561 5,535 5,520 5,510 5,522
32 1,553 1,545 1,568 1,555 q,498 5,510 5,497 5,502
~ 33 1,543 1,550 1.525 1.539 5,505 5,497 5,500 5,501
34 1.568 1,545 1.508 1.540 5,522 5,507 5.505 5,511
35 1.540 1,555 1.544 1,546 5,516 5,554 5.512 5.527
12-34rl
'!
,
**.END,
.CI'
' 12-36-1 t FRONT
12-36-2
SAMPLE NO. 12 COLUMN BENDING TESTS LUMBER SIZE 2x6 NO. I KD TR.
LOAD DEFLECT.IONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (II;.)
o_,,,.: o ] ® I ® I ^v~.__ _o' I o 1o I,vi;
,oo .... .;~-Z.°,,, .o~o -. .o,,, .,o,-I~'-'-~
4500 .411.601.421 .713 1.018 .671
~ooo .~ .~ .~{ I I -
~-~°° I F I---T--
6000 I
6500 { " ....... ~
~ooo ~ _ ~ { { _{
sooo -- { -4
ULTIMATE LOAD: 10,050 __ DATE: _1~.-8-~2 -_
.,
I 10-28-1' BACK 10-28-2
END #:
10-29-2
10-30-1 I FRONT
10-30-2
SAMPLE NO. 10 COLUMN BENDING TESTS LUMBER SIZE~.
LOAD DEFLECT.IONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (It;.)
_. 50o -i~;S"'--]/o;; .0385 .082 .115 .0,2
1000 .093. .132 .084 .163 ' .230 .145
1500 · 138 · 200 · 127 .248 · 350 · 221
2000 .183 .261 .170 .324 .459 .291
2500 .227 .326 .212 .402 .571 .364
3000 -272 .394 .255 .483 .685' .437
3500 .317 .458 .300 ~ .567 .803 .513
4000 .360 .522 .342 .654 .925 .591
4500 : .408 .590 .387 .744 1.054 I .672
6000
ULTIMATE LOAD: 9,475 COMMENTS: COLUMN DID NOT BREAK BUT TEST WAS STOPPED BECAUSE THE ~ENTER
. (,~0:#1
8-23-1
~i Q END
'+ lEI DOLE I ~-23-
®
3'0''-'¢' 4'6" '--¢~ 6'0" --'-':' '7'0"
8-24-1 FRONT ~-24-2
SAMPLE NO. 8 COLUMN BENDING TESTS LUMBER SIZE 2x6 NO. 1 KO TR.
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (Iii.)
1000 · .110 .152 .111 '.139 .207 .146
2000 .202 .281 .202 .290 .424 .294 I
2500 .246 .348 .250 .371 .538 .371 I"
3000 .292 .415 .297 I .447 .646 .44S I
3500 .335 .479 .342 .519 .749 .515
4000 I..~80.54~ .~88 .598 .857 I .589 i
4500_ .424 .610 .434 I .677 .975 .668
5000 ' .471.676 .481
5500 !
6000
6500 -,
ULTIMATE LOAD: 7,250 DATE: 12-~-82
11-33-1 11-33-2
BACK ....
11-32-1 "(-
..t.. 6" L.- 2'0"
®
M'IDDLE
~] 3'0''-~-] 4'6" "-~' 6'0"
END .-.~
7'0" m'J 9'0" "-~]
11-31-1 FRONT 11-31-2
SAMPLE NO. 11 COLUMN BENDING TESTS LUMBER SIZE 2x6 NO.~.
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (Il(.)
~" ___c)..__J ®,..1_® I_^v~. c) lc> ~) I~,,~
500 .054 .080 .059 .068 .110 .079
1000 " .105 .156 .113 .141 .220 .155
'~ 1500 .153 .229 .163 .223 .344 .235
2000 .203 .303 .214 .306 .467 .315
2500 .253 .376 .264 .394 .594 .398 I '
3000 .303 .450 .315 I .480 .720 .480 I _
3500 .354 .525 .365I .563 .843 .561 !
4000 .404 .600 .417I .650 .969 I .644t
-~:. ~o _____~____.__~_!._~: ....... _L_ .... , l- , .... Z_ ~ .... .
ULTIlqATE LOAD: 8,175 DATE: 12-8--~2
· 7-'19-1 '
t__ . BACK
7-19-;
7-20-1
-''-' 6" L " 2'0"
MIDDLE
END #;
7-20-;
7-21-1 FRONT 7-21-;
SAI,IPLE NO. 7 COLUMN BENDING TESTS LUMBER SIZE 2x6 NO. 1 KD
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE
1000 .133 .215 .197 .202 .315 .244
'~500 .190 .300 .260 .303 .471 I .357
2000 .251 .389 .324 .405 .629 .470
2500 .311 .476 .387 .504 .7815 .580
3000 .371 .565 .449 .609 .941 .700
3500 .429 .650 .510I .7171.104 .808
4000 .488 .739 .574 .832 1.280 I .932
4500 .549 .830 .639 .951 1.460 I 1.057
5000 ' .612 .921 .706
6000
6500
ULTIMATE LOAD: 7,000 COMMENTS: THE CENTER BOARD BROKE AT THE MIDDLE. DATE: ~2-8-8~
6-17-1
-:" 6"
MIDDLE '~-
3'0'''-~' '4'6"
END .~:
-S-17-2
6' 0"
7'0'~-c~' 9'0"
.6-18-1 FRONT
6-18-2
SAMPLE NO. 6 COLUMN BENDING TESTS LUMBER SIZE2x8 NO. 1 ~ TR,
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (Il(.)
c~.~ __~._].®1 ®l~v~. ml~) ~) I^v~
500 .029 .040 .035 .036 .055 .043
1000 .054 .076 .062 .073 .110 .083
3000 .151 .211 .163 .229 .337 .242
3500 .173 .243 .187I .267 .394 .283I
4000 .197 .276 .211 .307 .454 .323
4500 .2201.3o9 .235 .350 .516 .367
5000 '.244 .341 .259 I .395 .581 .412 I
6000 .291 ,408 .307 .489 .721 .506 I
6500 ~ .314 .439 .330 .540 .794 .555
7000 .339 .474 .354 I .591 .868 I .6051
~°°° .~° .-~ .~°~I I
ULTIHATE LOAD: 1),250 DATE: 12-8-82
5.13-1 BACK
5-13-2
. 5-14-1 '+ MIDDLE -~-
-:' 6" 2!0" '~ 3'0''~ 4,'6" ~' 6'0''~ '
END ~
s-14-2
I 5-15-1 I FRONT
5-15-L
SAMPLE NO. 5 COLUMN BENDING TESTS LUMBER SIZE 2x8 NO. 1 KD TR.
LOAD DEFLECTI'ONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (I!i.
500 __'031 __.041 .053 .043 .064 .046
1000 .057 .079 .082 .083 .125 .089
1500 · 082 · 116 · 108 · 125 · 187 · 133
2000 · 106 · 152 · 133 · 171 · 252 . 178
2500 ~ .132 .189 .159 .215 .319 .224
3000 .157 .226 .184 .262 .387 .270
3500 ,183 .262 .208I .308 .456 .317
4000 .207 __ .297 .232 .358 ,.529 .366
4500 .. .234._ .334 .257 .. .406 I .602 1 .414
I
5000 ' .259 .370 .282 .453 .672 .461'
_ 5500 .287 .409 .308 .'501 .742 .508
6000 .315 .447 .333 .549 .812 .553
6500 .342 .484 .359 .601 .889 .603
JLTi!~TE LOAD: 14,050 BOARD #15 BROKE NEXT TO THE SPLICE OF THE CENTER BOARD AND SPLIT
{ 4-10-1
L_ . BACK 4-10-2
4-11-1
]{- M'IDDLE
6'0" ----~ 7'0"
4-11-2
4-12-1 1 FRONT
4-12-2
SAMPLE NO. 4 COLUMN BENDING TESTS LUMBER SIZE 2x8 NO. 1 KD TR.
LOAD DEFLECTI'ONS W/O ·SPLICE (IN.)DEFLECTIONS W/ SPLICE (II~.)
o l ®1 ® olo la)
500 .02~6 ..... .043 .032 .040 .069 .060
1000 ' .053 .082 .059 .083 .136 .110
~1500 .080 .121 .08B .129 .204
2000 .107 .160 .111 .174 .272 .204
2500 .133 .197 .136 .222 .342 .251 I '
3000 .159 .236 .163 { .269 .411 .297
3500 .184 .273 .189 { .314 .476 .340 I
4000 .209 .311 .214 .359 ~542 .385'
4500 .- .236 .350 .241 .405 I ,611 .432
I
5000 '.260 .388 .267 .452 .680 .479'
5500 .285 .426 .294 .498 .750 .527
6000 .311 .465 .320 .549 .823 .576
6500 .336 .502 .346 .602 .903 .628
7000 .362 I .542 .373 .262 .992 .687
8000 .413 .619 .427
ULTII,tATE LOAD: 11,,,900 COMMENTS: SPLICE DID NOT FAIL. TEST WAS STOPPED BECAUSE THE STEEL.
BACK 3-7-2
'r
'1.3-7-1
3-8-1
I
6" J< -
--'~- MIDDLE '~-
' i
END #2
--~- 3-8-2
9'0" --~'1
3-9-1 I FRONT 3-9-2
SAMPLE NO. 3 COLUMN BENDING TESTS LUIqBER SIZE
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (II<.)
500 .018 .033 .026 .043 .066 .054
, I
1000 " .039 .065 .049 .084 .126 .099
1500 .059 .098 .073 .126 .187 .141
2000~ .079 ..128 .094 .166 .245 .180
2500 .100 .160 .117 .211 .309 .223
4000 .162 .254 .184 .343 ,..498 .349
4500 : .184 .286 .206 .389 .565 I .394
6000 ,249 .382 .275 .535 .771 .529
ULTII,~TE LOAD: 1Q,475 DATE: 12-3-82
BACK
1-1-2
1-2-1 + ~(IDOLE
6"L 2'~"--~3'0"-~ 4'6" ~6'0"
END #;
,.-2-2
1-3-1
FRONT
1-3-2
SAMPLE NO. I COLUMN BENDING TESTS LUMBER SIZE 2x8 NO. l KD TR
LOAD DEFLECTIONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (Ill.
~'.' (~ ~_] ~]^v~. c) l®~) I^v~,
.... 500 .026 .036 .026 .043 .076 .042
1000 .051 .072 .051 .085 .137 .084
~m~W 1500 .077 .108 .076 .128 .200 1.127t
2000 · 102 · 144 · 101 · 174 .265 · 171
2500 .127 .I80 .125 .215 .324 .211 I
3000 .152 .216 .149 .258 .388 .2.-.4
3500 I .176 .250 .172I .301 .450 .299 !
I
4000 I .20O .284 .195I .346 ..518 I .344 )
4500 .- .224 .319 .220 I .' .395 .586 i .391
6500 ., .322 .462 .3t6 .593 .868 .579
...._ ...... ?!' I I
ULTIMATE LOAD: 4,400 DATE: 12-~-82
, .L_74-1. . BACK 2-4-:
0 //1 :
2-5-1
-'~' 6" L
MIDDLE -~ .... I 2-5-;
2'~"; -- 3' 0"- 4'6" -~ 6'0" 7'0" 9'0"
l 2-6-1 2-6-;
FRONT
SAMPLE NO. 2 COLUMN BENDING TESTS LUMBER SIZE 2x8 No. 1 KD TI
LOAD DEFLECT,IONS W/O SPLICE (IN.) DEFLECTIONS W/ SPLICE (Il(.)
500 .029 .042 .035 .038 .056 .054
2500 .132 .181 .137 .194 .278 .201
3000 .156 .213 .159 .235 .337 .237
3500 .181 .247 .183 .275 .392 .274
4000 .203 .277 .204 .317 ~451 .313
6000 .303 .413 .296 .490 .693 .471
I ............ I
6500 . .328 .445 .318 .539 .762 .516
7000 .353 .481 .341 .586 .827 I .557I
ULTIMATE LOAD: 12¢950 COMMENTS: SPLICE DID NOT FAIL. COLUMN WAS I!4ISTING AND STEEL BE%M WAS
'TOP
16d NAILS
X----.BOTH s oE5®
4'6" ~ 6'0"
FRONT & BACK
A2
BOTTOM
LUMBER DIMENSIONS.
BOARD
NUNBER WIDTH DEPTH
® ® I ®avE. ® ® ® AVE.
1 1.500 1.500 1.500 1.500 7.312 7.312 7.312 7.312
2 1.500 1.500 1.500 1.500 7.312 7.250 7.250 7.270
3 1.500 .1.500 '1.500 1.500 7.312 7.312 7.312 7.312
4 1.495 1.499 1.505 1.500 7.250 7.312 7.250 7.271
5 1.508 1.507 1.510 1.508 7.312 7.312 '7.312 7.312
6 1.498 1.516 1.505 1.506 7.312 7.312 7.312 7.312
7 1.505 1.515 1.482 1.501 7.312 7.312 7.312 7.312
8 1.496 1.495 1.505 1.499 7.312 7.312 7.312 7.312
9 = 1.515 1.515 1.520 1.517 7.312 7.375 7.375 7.354
10 1.520 1'.503 1.510 1.511 7,312 7.250 7.250 7.271
11 1.496 1.491 1.512 1.500 7.'312 7.250 7.~17 7,291
12 1.487 1.497 1.480 1.488 7.312 7.312 7.250 7.291
13 1.510 1.505 1.517 1.511 7.312 7.312 7.250 7.291
14 1,518 1.504 1.508 1.510 7.912 7.312 7.312 7.312
1.505 1.490 1.498 7.312 7.500 7.312 7.375
15
1.500
16 1.470 1.505 1.505 1.493 7.250 7.312 7.312 7.291
17 1.512 1.498 1.510 1.507 7.250 7.250 7 312 7.271
ENO #~
SAMPLE DIMENSIONS & In[NTIFICATION
END #2
P/2
2-1/2'
2-1/2'
P/2
7-16d NAILS EACH SiDE
UNSPLICED COLUMN
1 1 I
SAHPLE NUMBER BOARD NUMBER END NUMBER
~-1-1 I 1-1-2)
1-2-1 i 1-2-2
1-3-1 I 1-3-2
IP/2 ~ P/2
~1-1/2L
SPLICED COLUMN
DATE:
SHEET OF
BUILDINGS
SHEET OF
MORTON BUILDINGS GENERAL SPECIFICATIONS
LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4B
COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8
POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE IN CONFORMANCE
WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN
EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS.
FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'-8" BELOW GRADE
(SEE PLANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN
THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSI) IS POURED IN PLACE TO THE
SPECIFIED THICKNESS (SEE PLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN}, THE
COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT B" INTERVALS OR BACKFILLED WITH
CONCRETE (SEE PLANS).
TREATED LUMBER - PRESSURE PRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE
NO, 1 OR BETTER SOUTHERN YELLOW PINE AND CENTER MATCHED OR NOTCHED AND GROOVED,
PRESSURE TREATED TO A NET RETENTION OF .4 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY
APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A.
FRAMING LUMBER - SIDING NAILERS ARE 2x4 S4S OR 2xB SPF NO. 2 OR BETTER SPACED APPROXIMATELY
36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO.
2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O,C. ALL OTHER FRAMING LUMBER IS NO. 2 OR
BETTER.
ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS
REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL INSPECTION IS
CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN
ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING,
SIDING PANELS IKYNAR 500 / HYLAR 5000) - 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH
AN ADDITIONAL BAKED-ON KYNAR $00 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL, PAINT THICKNESS
ON EXTERIOR.
ROOFING PANELS (FLUOROFLEX 2000 TM) . 0.019" MIN. AZ55 GALVALUME WITH AN ADDITIONAL
BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500 / HYLAR 5000 TOPCOAT WITH A TOTAL
MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR.
TRIM - DIE-FORMED TRIM OF 0.017" MIN,, G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES,
RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AB ROOFING OR SIDING PANELS.
GUTTERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH
TRIM, ON BOTH SIDES OF THE BUILDING.
ADDITIONAL NOTES
1 .) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED
AS PART OF THESE DRAWINGS.
2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE
PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS
REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS,
AND CORRIDORS.
3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING
PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES,
4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON
SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION.
5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC,, HYLAR 5000 IS A
TRADEMARK OF SOLVAY SOLEXIS.
2x4EK 11/05
SHEET INDEX
SHEET# DESCRIPTION
G1 OF G1 SPECIFICATIONS & SHEET INDEX
S1 OFS10 COLUMN PLAN
S2 OF S10 TRUSS PLAN, 8, DETAILS
S3 OF S10 TRUSS DRAWING, PORCH FRAME & PURUN LAYOUT
S4 OF S10 i ELEVATIONS
S5 OF El0 SECTIONS & DETAILS
S6OFS10 SECTIONS&DETAILS
S7OFB10 SECTIONS&DETAILS
S8 OF S l 0 SECTIONS & DETAILS
S9 OF S10 SECTIONS & DETAILB
S10 OF S10 FASTENING SCHEDULE & DETAILS
ALL
BUILDING DESIGN CRITERIA
BUILDING CODE 2007 BUILDING CODE OF NY
USE GROUP U - AGRICULTURAL
CONSTRUCTION TYPE VB
FLOOR AREA 1620 SQ FT
MEAN ROOF HEIGHT 1B.00 FT
BUILDING CATEGORY I
MINIMUM LIVE ROOF LOAD DESIGN SEE BELOW
ROOF SNOW LOAD* 12.6 PSF
GROUND SNOW LOAD 20 PSF
WIND SPEED (V~s) 120 MPH
WIND IMPORTANCE FACTOR 0.77
EXPOSURE CATEGORY C
INTERNAL PRESSURE COEFFICIENT -+0.18
BUILDING DESIGN CONDITION ENCLOSED
WIND LOAD DESIGN ASCE 7 METHOD 2
MAX DESIGN ELEVATION 1000 FT
ZONE 1E 28.44 PSF
ZONE 2E -26.61 PSF
ZONE 3E -18.17 PSF
ZONE 4E 16.99 PSF
ZONE 5E 16.81 PSF
MAIN WINDFORCE RESISTING SYSTEM
(ALL FORCES ACT NORMAL TO THE SURFACE) ZONE 6E -12.98 PS F
FOR ZONES SEE MWFRS ON ELEVATIONS PAGE) ZONE I 14 85 PSF
MAXIMLJ M VALLJE SHOWN)
ZONE 2 -18.52 PSF
ZONE3 13.81 PSF
ZONE 4 -12.68 PSF
ZONE 5 12.34 PSF
ZONE 6 -10.00 PSF
ZONE 1 14.40, -22.99 PSF
COMPONENT & CLADDING WIND LOADS ZONE 2 14.40, -40.02 PSF
ALL FORCES ACT NORMAL TO THE SURFACE)
{FOR ZONES SEE ELEVATIONSI ZONE 3 14.40, -59.19 PS F
ZONE 4 25.13, -27.25 PSF
ZONE 5 25.13, 33,65 PSF
TYPICAL LUMBER SPECIFICATIONS ~ 2001 NDS
SIZE DESCRIPTION BENDING VALUE Fb
2x4 NO. I & 2SPF 1313 PSI
2x4 2IOOf MSR SPF 2100 PS1
2x6 NO 1 &2SPF 1138PSI
2x6 NO, T SYP 1650 PSi
2x8 NO. 1 SYP 1500 PSi
2×10 NO, 1 SYP 1300 PSI
2xl2 NO. 1 SYP 1250 PSi
ALL 1950f MSR SYP 1950 PSi
1 1/2"xl 6" LAMINATED VENEER LUMBER 2800 PSI
3 1/2"xlB" GLU LAM 1680 PSI
5 I/4"x 16 1/2" GLU-LAM 2400 PSI
5 I/4"x19 1/2" GLU-LAM 2400 PSI
NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS.
MINIMUM LIVE ROOF LOAD DESIGNS FOR CONSTRUCTION, MAINTENANCE,
REPAIR, AND OTHER TEMPORARY LOADS PER SECTION 1607.11.2
1 . ROOF PURLINS AND OTHER SECONDARY STRUCTURAL
* ROOF SNOW LOAD CALCULATIONS
Ps = 0.7xCexlxPgxCtxCs
Ce = SNOW EXPOSURE FACTOR = 1.0
I = IMPORTANCE FACTOR = 0.8
Pg = GROUNDBNOWLOAD=20PSF
Ct = THERMAL FACTOR = 1.2
Cs = ROOF SLOPE FACTOR = 0.94
p§ -- 0.7x1.0x0,Bx20xl.2x0.94=12.6PSF
G
EARTHQUAKE DESIGN DATA TABLE
0.2 BEC SPECTRAL RESPONSE
ACCELERATION (Ss) 0.250
1.0 SEC SPECTRAL RESPONSE
ACCELERATION (S~) 0.070
SEISMIC DESIGN CATEGORY ]~
BUILDING CATEGORY [TABLE 1604,5) !
SITE CLASS D
SEISMIC USE GROUP !
BASIC STRUCTURAL SYSTEM AND #2 LIGHT FRAMED WALLS WITH SHEAR
SEISMIC-RESISTINg SYSTEM PANELS
RESPONSE MODIFICATION FACTOR (R) 7
ANALYSIS PROCEDURE SIMPLIFIED ANALYTICAL PROCEDURE
SEISMIC DESIGN BASE SHEAR 1100 LBS
UNDERWRITERS CERTIFICATE
J , %c.'EED W
OOCUPANOyOR
USE 18 UNLAWFUL
THOUT CERTIFICATE
OFOCCUPANCY DATE:~Oq B
765-1802 8AM TO q ,
~~*~ 32' INSULATIoNROUGH - FRAMINi} ,; E
4. FINAL- CONSTRU','7 OH MUST
BE COMPLETE
ALL CONSTRUCTION 5F¢,', ,v~Z~EF THE
EQUrREM~NTS OF TH ~ iL, ,[:S OF NEW
DESYORKGNSTATE.OR NOT r~' [~"~ ~ ~'~ 'ATER¢61[~ ~ RUNOFF
MEET THE REQUIREMENTS OF THE 0F THE TOWN CODE,
CODES OF NEW YORK STATE.
~ HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR
THIS BUILDING WAS PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT [ AM A DUI __
LICENSED/REGISTERED PROFESSIONAL
DATE:
WARNING:
IT IS A VIOLATION i
PERSON UNLESS ACTING UNDER THE
LICENSED ARCHITECT OR LICENSED ENGINEER TO
ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM.
CERTIFICATION OF
NAILING & CONNECTIONS
REQUIRED.
CUTCHOGUE, NY
O
CD
II I
7
III ~:
~DRAWN BY: ~AOSIER
DATE; 11/13/08
CHECKED BY R.M.
DATE: 11/18/0B
REVISED DATE: ....
REVISED DATE: ....
REVISED DATE: --
REVISED DATE: ....
SCALE: AS NOTED
BUILDING COLUMN LOCATION DIMENSIONS
9
PORCH COLUMN LOCATION DIMENSIONS
29'-9"
22'-4 1/2" --
14'-11 lj2"
COLUMN PLAN LEGEND
a - ~2x6 LAMINATED COLUMN LOCATION
[] - 6068 9-LITETEMPERED GLASS IN LEAF WITH EMBOSSED CROSSBUCK
FIBERSTEEL WALKDOOR(S), OUT SWING WITH LOCI(SET RIGHT SIDE ACTIVE
~ - (2) 4429 9-UTE HAYEIELD SLIDING WINDOW(S) WITH 15'~35"
LOUVERED SHUTEERS
(~) - (2) 14'-9"x14'4~'SINGLESLIDINGALUMASTEELEND DOORJS)
'~ - 81MBASEANCHORS
- (6) 3065 SKYUTE(S) )VERIFY LOCATION)
- (1) 3'-6" x 3'-6" CUPOLA WITH "M" 30" WEATHERVANE NON-FUNCTIONAL
- ALL STEEL FASTENED WITH STAINLESS STEEL SCREWS
<~ - [2) 7/16" OSB SHEARWALL ISEE SHEET S8 OF S10 FOR DETAILS)
16"R- 16" DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX
CONCRETE BELOW BOITOM OF LOWER COLUMN WITH ADDITIONAL
READY-MIX TO TOP OF 218M STILT (9"-+]. PLACE CONCRETE
BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION.
18"R- 18" DIAMETER FOOTING WITH 8" THICK MINIMUM READY-MIX CONCRETE
BELOW BOITOM OF LOWER COLUMN WITH ADDITIONAL READY-MIX TO
TOP OF 21BM STILT [9"±). PLACE CONCRETE BELOW AND ABOVE BOITOM
OF LOWER COLUMN IN ONE OPERATION.
24"R- 24"DIAMETER FOOTING WITH 10"THICKMINIMUMREADI-MIXCONCRETE
BELOW BO1TOM OF LOWER COLUMN WITH ADDITIONAL READI-MIX TO TOP OF 224M
STILT (~"-+). PLACE CONCRETE BELOW AND ABOVE BoI'rOM OF LOWER COLUMN IN
ONE OPERATION.
7'-4 1/2"
J ~ 1'-41/2"
1 '-~' VENTED PORCH OVERHANGS
16"R
/16"R
29'-9"
14'-9 1/2"
7'-4 1/2"
7'-6" Jr x
7'~. 1/2" \
1'~" 'VENT~ SIDEWALL OVERHANGS
COLUMN PLAN
ROUGH OPENING SCHEDULE
U NIT SYMBOL WIDTH H EIGHT
FROM LEGEND
[] 74 3/4" 81"
,~ 52 1/4" 33 5/8"
SCALE: ~ I
1' 4'
16'
Ii ~lCj~'128-0826
CUTCHOOUE, N~Y _
n
II I
II I
II I
II I
DRAWNBY: MOSIER ·
DATE: 11/13/08
CHECKED BY, R.M,
DATE: ,11/18/DB
REV.~ED DATE: ..-
REVISED DATE: ..-
REVISED DATE: ..-
REVISED DATE: .--
B NO.128-0826 J
2x4 PURLIN
HEADLOK ,19'S~6.(7' FLATHEAD LAG SCREW
(ICC-ES REPORT ESR-10?8)
(~) (1} #9x1" TRU-GRIP SCREW ON PEAK SIDE AND
(2) #9X1" TRU-GRIP SCREWS ON F-AVE SIDE OF
PURLIN IN HOLES SHOWN (JOINT MUST BE TIGHT
BEFORE FASTENING CLIPS
20 GA. GALVANIZED
PURLIN CONNECTOR
7'-5 1/2"
7'-5 1/2"
2x4 BU'I-I'ED PURLIN DETAIL
(PURLIN CONNECTED WITH
6" IfEADLOK FLATHEAD LAG SCREW)
SCALE: ] 1/2": 1'-0"
80' 4090 S.C. TRUSS~
R.S. NAILS
PER CONNECTION
~(1 ) 2x6 END COLUMN EXTENSION
DETAIL 2
SCALE: 1 1/2"= 1"-0"
J2) 20d R.S. NAILS IN OVERHANG FRAME
2x4 BEV. P
OVERHAN
TOE NAIL OVERHANG RAFTER
TO OVERHANG NAILER WITH
IlJ 16d R.S. NAIL EACH SIDE
2X6 OVERHANG NAILER
2x4 TRUSS HEEL BLOCK
w/14) 20d R.S. NAILS
1/2"
TRUSS/BRACING PLAN
I I
7'-6" ,Ir 7'-6"
0
'T
1/2"
TRUSS/BRACING PLAN LEGEND
30' O '"
(~ - 4 90 S.C, TRUSSES @ 7-60.C,
(,~ - 2x4 TRUSS TIES @ 5'-0" C.C.
~) - 2x6 DIAGONAL END BRACES @ 7'-6" C.C.
(TO EXTEND TO FIRST TRUSS IN FROM ENDWALL)
(~ -8' PORCH END FRAMES
2x4 TRUSS TIE ~
(7) 20d R.S. NAIM
~'~ 60d R.S. NAILS
30' 4090 S.C, TRUSS
DETAIL 1
SCALE: 1 112"= 1'~"
(3) 2x6 CORNER COLUMN
2' 8'
SCALE: ~ I
4'
60d R.S. NAIL
LOWER TRUSS CHORD
(1) #9×]"TRU-GRIP SCREWS ON PEAK SIDEAND ~~
12) ON EAVE SIDE IN HOLES SHOWN.
(JOINT MUST BE TIGHT BEFORE FASTENING CLIPS]
16'
//~/~ (6] 20d R.S. NAILS
/ L PER CONNECTION
I I '--~ (21 2x6 END COLUMN
jEXTENSION
DETAIL 3
SCALE: 1 1 [2" = 1'~0"
20 go. GALVANIZED PURLIN C~ONNECTOR
2x4 TRUSS TIE DETAIL
n
II I
Il I
S2oFS10
SL
EP
TC
7-6-4
7-6-4
7-9-0
22-2-12
7-44
I 1.25x16.25 --
C
7-11-2
29-9-0
7-6-4
f HO ]-3-8
A
T1
WGI
W2
W3
W4
3.7B×S//
D
W5
T2
WG2
&~SG-MN~B-6.2Sx~7.B II
&lBO-MN18-1 1.2$xlB I I
0.05202 H G
# 18G-MT8H-7x165
F
B2
&lBG-MN18-6.25X17.5 II
&lBO MN18-11.25x15 j I
BC
EP
SL
14 8-12
TRUSS DESIGN LOAD = 477 PLF
REQUIREDTRUSSLOAD= 24 PSF AT 7'-6"
LIVE LOAD 20 PSF
DEAD LOAD 4 PST
CEILING LOAD PSF
TOTAL LOAD 24 PSF
O.C.= 180 PLF
29 9-0
29-9-0
TRUSS DESIGN SPECIFICATION:
Truss has been designed by computer using Robbins
Engineering Software and specificatrons of recognized
engineering principles, Trusses are manufactured by Morton
Build?ngs, Inc.
LUMBER SPECIFICATION (2001 NDS for Wood Construction):
Lower Chord -- No. 1 K.D. - 19 or 2400f - MSR 2.0E Southern Pine
Top Chord --- No. 1 K.D. - 19 or 2400f - MSR 2.0E Southern Pine
Web Member~ -- No. 1 K.D.- 19 Southern Pine
TRUSS PLATE SPECIFICATION IICBO Evaluation report No. 29291:
ASTM A-653, Grade A 20 Ga, and 18 Ga. where noted,
galvanized steel Morton truss plates identihed by a hexagon
stamped every 1 1/4" along the center ct the plate.
30' S.C. 4090 TRUSS
SCALE. 1/2"= 1'-0"
30' SC 4090
3' WiDE
(ZONE 2 &
LIVE LOAD 20 PSF
DEAD LOAD 6 PSF
CEILING LOAD 2 PSF
TOTAL LOAD 28 PSF
TRUSS DESIGN SPECIFICATION:
Truss has been designed by computer using the Purdue
Plane Structure Analyzer lAW current standards and
spe¢ifTtahons of recognized engineering principles.
Trusses are manufactured by Morton Buildings, Inc,
LUMBER SPECIFICATION (2001 NDS for Wood ConstructTon):
Lower Chard -- No. 1 K.D. - 19 Southern Pine
Top Chord -- No. 1 K.D.- 19 Southern Pine
Web Members -~ No. 1 K.D. - 19 Southern Pine
TRUSS PLATE SPECIFICATION (ICBO Evaluation report Ne. 2929):
ASTM A-653, grade A 20 Ga. and lB Ga. where noted,
galvanized steel Morton truss plates identified by a
hexagon stamped every 1 1/4" along the center of the plate.
3'-1 7/16"
Web
2-3x5 PL.
1'-1 11/16"
3' WIDE
(ZONE 2 &
2x6 LOWER CHORD
8'-10 1/2" 2-8x10 PL. ~
8' PORCH END FRAME
SCALE: I/2"= 1'-0"
6 1/2',~
2x4 PURLIN]
30'
O - INDICATES PURLINS TO
BE
FASTENED
w/HEADLOK .19"x 6.0" FLATHEAD LAG
SCREW.
WIDE BUILDING PURLIN LAYOUT
SCALE: I/2"= lU0"
CUTCHOGUE, NY
III
III
7
II I
I
II1-~
I I I
DATE: I 1/13/08
CHECKED BY: ~.M.
DATE: I 1/18/08
REVISED DATE: ----
REVISED DATE: ---
REVISED DA TE' .---
REVISED DATE; .---
ISCALE; AS NOTED
SHEET NO,
S3oPSlO
3.0' WIDE
(ZONE 2 & 3)
3.0' WIDE
{ZONE2 & 3)
WIDE
(ZON~ 5J
12
3'q7' WIDE
(ZONE 2 & 3)
(ZONE 2) ~
{ZONE 3) ~
3'q3" WIDE
[ZONE 51
27'-6" c~ 26'-6"
Ill
3]
/// ,(ZONE 1)
'/////. ~/////, ~/////, '/////~ '////.: ~/////) ~////,/////~ '////.b ~/////, ~/////, ~/.~ '/////x '////.~ ~/////,
, !
' 12'-6" 29'-0" 7'-6"
-~ ~ SOUTH ELEVATION ~
3L
(ZONI~ 2 & 3) 12
HI-RIB STEEL SIDING
T#21 CORNER TRIM
T# 167 TRANSITION TRIM
HI-RIB STEEL WAINSCOT
T#167 BASE TRIM
3'-0" WIDE
(ZONE 2 & 3)
3'-0" WIDE
(ZONE $)
' WIDE
(ZONES 2 & 3)
t 24.0. W,DE IZONE 41
3.0' WIDEI 24.0' WIDE (ZONE
[ZONE 5)
22'-0 1/2"
4E 4 6.~ 5~~ 6E
m
Reference
Corner
3.0' WIDE
(ZONE 2 & 3}
3.0' WIDE
7'-11 1/2" I [ZONES)
22'-0 1/2" 7'-11 1/2"
3.0' WIDE
(ZONE 5)
EAST ELEVATION ~' WEST ELEVATION
3'-0" WIDE 3'-0" WIDE
[ZONE 2 & 3} (ZONE 2 & 3}
(ZONE 3) ~
**STITCH SCREW ROOF STEEL LAP RIBS 3 L.F. (~)
FROM EACH ENDWALL wJ#gxl" TRU-GRIP
(ZONE 2) ~ SCREWS. (SEE SHEET S7 OF S9 FOE DETAILS.)
[ZONE 3J ~
~TEEL WAINSCOT
.I, 14 ~'-0"W,DE(ZO.E4~ '1, I.
3'~"WIDE ~ ~ 3'~"W~DE
CUTCHOGUE, N~Y _
d
II I
II I
b
II I
L
T
ORAWNBY; MOSIER ·
DATE,' 11/13/08
CHECKED 8¥; R.M.
DATE: 11/18/08
F?EV, GED DATE: --
~EVISED DATE --
~EViSED DATE ---
REVISED DATE: ---
(ZONE 5)
[ZONE 5)
NORTH ELEVATION LC$cALE:ASsS4oH%N~']oNOTED
FLUOROFLEX
2x4 PURLINS @ 23" O.C.
(NO. 2 SPF}
HEADLOK .19"x6.0" FLATHEAD LAG SCREW
2x4 BEV. PURLIN
W/RE MESH
FILLER STRIP
2x6 BEV. FASCIA
5" O.G. GUTrERS --
T#144 & 146 FASCIA TRiM
~) ~ SOFFIT
HI-RIB/SOFFIT CAP
B0' 4090 S.C. TRUSS
~ HEADLOK .1~6.
]" FLATHEAD LAG SCREW
GABLE PURLIN FLASHING
T# ! 6 GABLE TRIM
T# 194 TRIM
SOFFIT
~IhRIBJSOFFIT CAP TRIM
30' 4090 S.C. TRUSS
~ 2x6 E.C.E.
~ KYNAR HI-RIB STEEL
~) 1421 20d R.S. NAILS
KYNAR HI*RIB STEEL
SADDLE
,INATED COLUMN
14'~'
GRADETO HEEL
18"LOWEST
MEMBER CUT-OFF
FINISH GRADE
( 3 ) ROWS 2x6 NAILERS (2100 MSR SPF)
3-2x6 LAMINATED COLUMN
2x2 VERTICAL BLOCKING
AT COLUMN LOCATION
T# 167 TRANSITION TRIM
2x6 NOTCHED NAILER
KYNAR HI-RIB STEEL WAINSCOT
7/16" OSB PROTECTIVE LINER
T# 167 BASE TRIM
( 1] ROW 2xB TREATED SPLASHBOARD
6" CONCRETE FLOOR
B1M BASE ANCHOR
4" MINIMUM COMPACTED GRANULAR BASE
FINISH GRADE
NOTE:
FOOllNGS ARE DESIGNED FOR A
2000 PSF SOIL BEARING CAPACITY.
LOCAL CONDITIONS MAY RE(~UIRE
MODIFICATIONS.
218M (14 GA.) COLUMN STILT ~)
8" THICK MINIMUM READY-MIX CONCRETE
BELOW BOTrOM OF LOWER COLUMN WItH
ADDITIONAL READY-MIX TO TOP OF 218M STILT (9"-+).
PLACE CONCRETE BELOW AND ABOVE BOTTOM OF
LOWER COLUMN IN ONE OPERAIlON.
SIDEWALL SECTION A
SCALE: I/'Z' = 1'-0"
CONCRETE FLOOR NOTES
1. 3500 PSi. B 1/2 BAG MIX CONCRETE
2. SLOPE GRADE AWAY FROM BUILDING @ 1" PER FOOT FOR A
MINIMUM DISTANCE OF 10' PLUS OVERHANG WIDTH
3. A VAPOR RETARDER IS NOT MANDATED PER IBC SECTION 1710
EXCEPT[ON 3. UNLESS THE FLOOR WILL BE COVERED BY
MOISTURE SENSITIVE FLOORING MATERIALS OR IMPERMEABLE
FLOOR COATINGS OR WHERE THE FLOOR WILL BE IN CONTACT
WITH ANY MOISTURE SENSITIVE EQUIPMENT OR PRODUCT
4. CONTRACTION JOINTS UNIFORMLY SPACED18' O.C. OR LESS
FLUOROFLEX HI-RIB STEEL (~)
2x4 PURLINS @ 23" O.C. J~)
lNG. 2 SPF)
[4J 0.135" x 2 1/4" R.W. NAILS OR 16d R.S. NAILS
(1] 20d R.S. NAIL THROUGH STRAP
& INTO BRACE
2' END BRACE STRAP W/PRE-PUNCHED
HOLES (BEND TO FIT) FASTENED W/
J3) 0.140x 1 lJ'Z' R.S. NAILS
2x6 DIAGONAL BRACING FASTENED
TO COLUMN W/(4) 16d R.S. NAILS
--~ 2x4 TRUSS TIE
STILT ISOMETRIC
1/4"xl 1/4"x14 GA. SUPPORT ANGLE
FASTENED TO COLUMN AT EACH
CORNERWITH (3] .148"O x2'
STAINLESS NAILS. (12TOTAL NAILS
PER COLUMN)
14 GA. CHANNEL WITH 1/4" PLATED
RIVET TO SUPPORT ANGLE
UNDLSTURBED SOIL
STILT NOTES
1. INSTALL PRESSURE TREATED
LOWER COLUMN WITH STILT IN
THE AUGURED HOLE.
2. POUR 9" MINIMUM THICKNESS OF READI-MIX CONCRETE INTO
THE HOLE AS SPECIFIED.
3. BACKFILL AND COMPACT THE
ANNULAR SPACE AROUND THE
COLUMN TO GRADE WITH SOIL
AUGURED FROM THE SITE.
NOTE:
THIS SECTION IS THE SAME AS
SECTION "A" EXCEPT FOR
THE ITEMS AS NOTED.
,NCRErE FLOOR
4" MINIMUM COMPACTED GRANULAR BASE
Jr 16"O
[14 GA.) COLUMN STILT
BELOW BOTTOM OF LOWER COLUMN WITH
ADDITIONAL READI-MIX TO TOP OF 218M STILT (9"-+).
PLACE CONCRETE BELOW AND ABOVE BOTrOM OF
LOWER COLUMN IN ONE OPERATION.
ENDWALL SECTION B
SCALE: 1/2'=
INTERIOR
EXTERIOR
I .... NAIL KEY
J0.14B X4 (20dj NAILS
j0.131" X 3 I/2" HOT DIPPED GALVANIZED (HDG) RING SHANK NAILS
3-2X6 COLUMN SPLICE FASTENING DETAIL
~CALE: 1/2" = f-Cf
CUTCHOGUE, NY
II I
'DRAWNBY; MOSIER ·
DATE; 11/13/0B
CHECKED BY; R.M.
DATE; 11/18/08
I~EVISED DATE; ---
REVISED DALE; ---
F?EVISED DATE: --- ,,~
SCALE:AS NOTED
6" OSB
BETWEEN
NAILER AND HEADER TOE NAIL WITH
(4) 16D R.S. NAILS, FASTEN 2x6 BLOCK
TO LAMINATED COLUMN WITH (5)
20D R.S. NAILS, STAGGERED
ATTACH TO 2x6 BLOCK
WITH (6) 20D R.S. NAILS.
-- ATTACH END PORCH FRAME TO 2<4
BLOCK WITH (7) I oD R S N,~,lLb
~D PORCH FRAME HANGS 1/2" OVER
EDGE OF PORCH CORNER COLUMN
-- 7/16 OSB SHIM
FRAME
PORCH ENDS @ COLUMN
112"x5 1/2" M. BOLT
& (6) 20d R.S. NAILS
T#178
BEV. FASCIA
T#144/146 TRIMS ~
2x8 NAILER FASTENED W/(4) 20d R.S. NAILS
T#6 & T#167 TRIMS
2x4 ADDITIONAL PURLIN
7/16 OSB SHEATHING
& 15# ROOFING FELT
B' PORCH END FRAME @ 7'-5 1/2" B.C. ~
FLUOROFLEX k
~ 2x4 PURLINS 23" O.C,
(2100 MSR)
22"
CUT OFF
2x6 BLOCK
2X4 SOFFIT '~ SOFFIT ~/
SUPPORTS
(~ ~) ADJ. JOIST HANGER
2x10 HEADER FASTENED
W/(6) 20d R.S. NAILS
(2) ROW 2x6 NAILER
(2100 MSR SPF)
T#39 COLUMN COVER
3 2x6 LAMINATED COLUMN
/~6" CONCRETE FLOOR
8'-1 1/2"
2x6 BLOCK. ATTACH TO COLUMN
WITH (5) 20D R.S. NAILS, STAGGERED.
2x4 BLOCK. ATTACH TO 2x6 BLOCK --
WITH (6) 20D R.S. NAILS.
ATTACH END PORCH FRAME TO --
2x4 BLOCK WITH (7) 16D R.S. NAILS
2x6 BLOCK FROM BOTTOM OF --
2xl 0 HEADER TO TOP OF FIRST
NAILER
FASTENED TO END FRAME WITH .19"x6.0"
HEADLOK FLATHEAD LAG SCREWS
7/16
r-m
ATTACH END PORCH FRAME TO
COLUMN WITH (5) 20D R.S. NAILS
2x6F_.. BEVELED FASC~
? ·
/
END VIEW OF END PORCH FRAME (SHOWN WITH END OVERHANG)
NOTE:
THIS SECTION IS THE SAME AS
SECTION "A" EXCEPT FOR
THE ITEMS AS NOTED,
1 1/2"xl 7/16"x4 1/2" FRAMING CLIPS
2x10 NAILER FASTENED W/(6) 20d R.S. NAILS
2x10 NAILER-
ATTACH TO COLUMN
WITH (6) 2OD R.S. NAILS
2x6 BLOCK BETWEEN
2x10 NAILER AND 2x10
HEADER. FASTEN TO
COLUMN WITH (4) 20D
R.S. NAILS.
OSB WITH 1-8/4" R.S, COIL NAILS --
12" B.C. TOP AND BOTTOM
qCRETE FLOOR
81M BASE ANCHOR
4" MINIMUM COMPACTED GRANULAR BASE
2x10 HEADER
ATTACH TO COLUMN
WITH (6) 20D R.S. NAILS
COLUMN
)4 1/2") FRAMING CLIP EACH SIDE WITH(~
SLOT DOWN, ATTACH EACH TO PORCH FRAME WITH
(6) #9 x 1 1/2" TRU GRIP SCREWS AND TO 2x6 BLOCK
& 2x10 NAILER WITH (6) #9 x 1 I/2" TRU-GRIP SCREWS
USP JH20 JOIST HANGER. ATTACH TO PORCH
FRAME WITH (4) 10d 2 7/8'x .148" DIA.
GALVANIZED POLE NAILS AND TO 2x10
HEADER WITH (2) #9 x 1 1/2" TRU-GRIP SCREWS
& (12) 0.131"x 1 1/2"TC POSff[VE PLACEMENT
GUN NAILS.
PORCH FRAME ATTACHED AT A COLUMN
CUTCHOGUE, N~Y _
OB ~0.128-0826
n
O
II I
III
7
~DRA WN BY: MOSIER
DA TE: 11 / 13/08
CHECKED BY; R.M.
DATE: 11/18/08
REVISED DATE;
REVISED DATE; --
~REVISED DATE:
J6" LONGER LOWER
8' PORCH SECTION C
SCALE: 1/2" = I' 0"
1
218M (14 GA.) COLUMN STILT
8" THICK MINIMUM READY-MIX CONCRETE
BELOW BOTTOM OF LOWER COLUMN WITH
ADDITIONAL READY-MIX TO TOP OF 218M
STILT (9"+_). PLACE CONCRETE BELOW AND
ABOVE BOTTOM OF LOWER COLUMN IN
ONE OPERATION.
ISCALE; AS NOTED
SHEET NO.
S6oES10
HEIGHT
OF WINDOW
I/2" WOOD SCREWS FASTENED THROU( ;H THE WINDOW JAMB FLASHINGS
INTO THE 2"x4" ROUGH FRAMING. PRE-DRILL tOLES 10" O,C. IN WINDOW JAMB FLASHINGS TO
ACCEPT WOOD SCREWS, SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL.
O.S.B. SHEATHING IS 1" WIDER THAN THE * VIDTH OF THE WINDOW
FROM OUTSIDE OF TRIM TO OUTSIDE OF ] ~IM.
O.S.B. SHEATHING IS 1" TALLER THAN THE HEIGHT OF THE WINDOW
FROM OUTSIDE OF TRIM TO OUTSIDE OF ]'RIM.
WIDTH
OF WINDOW
7/16" OSB PANEL
SILL FLASHING
FIN WINDOW SECTION
WINDBOURNE DEBRIS PROTECTION - FIN TV PE WINDOW
7/16" OSB PANEL
FINNED WINDOW ~
#8 x 3 1/2" WOOD SCREWS @ 10" C.C.
FIN WINDOW JAMB DETAIL
I/2" WOOD SCREWS @ lC' O,C. FASTENED THROUGH THE ALUMINUM DiOOR
SIDE
JAMBS
INTO THE .~K4 ROUGH FRAMING. PRE-DRILL HOLES IN ALUMINUM DOOR JAMS~ TO
ACCEPT WOOD SCREWS. SCREWS ARE NOT REQUIRED IN THE HEAD OR THE ~ILL,
HEAD FLASHING
/2" WOOD SCREWS SPACED
AS SHOWN ABOVE TO AVOID DOOR
INSTALLATION SCREWS
7/16" OSB PANEL
NOTE:
DOOR PANEL AND W~NDOW PROTECTION
DETAILS ARE FOR INSTALLATION
INSTRUCTIONS ONLY, AND ARE NOT
PROVIDED OR INSTALLED BY MORTON
SUILDINGS' INC. OR MORTON SUILDINGS'
SUSCONTRACTORS AND ARE THE OWNERS
RES PONSIBILli'Y.
-- 2"x4" ROUGH FRAMING
WALK DOOR JAMB DETAIL
-- OSB PANELIS I"WIDERTHANTHEWIDTNOFTHE DOOR
FROM OUTSIDE OF TRIM TO OUTSIDE OF TRIM
HEAD FLASHING
7/16" OSB PANEL
DOOR SLAB
#gXl" S.S,I.D. SCREWS W/WASHERS
INTO PURLINS
#9xl" S.S.I.D. SCREWS W/WASHERS USED
TO STITCH THE GASLE TRIM TO THE STEEL
SETWEEN PURLINS
1 :2 13
FIRST SCREW IN THE FLAT AT THE TOP AND
BOTJ'OM PURLINS W/#9x1" S.S.I.D. SCREWS
SCREW LAP RIB FIRST. THEN THE OTHER
TWO RISS, USE #9x2" S.S.LD. SCREWS
NOTE: SET SCREWS PERPENDICULAR TO
PANELS,
USE AN ERASER TO MAKE MARK ON
PANELS SHOWING WHERE PURLINS
ARE LOCATED (DO NOT USE PENClL).
.... / WASHERS USED
#9x1"S S I D SCREWS W
TO STITCH THE LAP RIBS SETWEEN THE
PURLINS
#9xl" S.S.I.D. SCREW W/WASHER INTO EACH PURLIN
(CENTERED BETWEEN HI-RIB AND FIRST MINOR RIB)
STITCHED ROOF STEEL ATTACHMENT DETAIL
SC~ALE: 1/2"= I'~)"
(1 '-g" OVERHANGSJ
#9x1" S.S.I.D, SCREW
TO STITCH THE GABLE TRIM TO THE STEEL
BETWEEN PURLINS
#9x1" S.S.I.D. SCREWS W/WASHERS
INTO PURLINS
T#16 GABLE TRIM
2x6 FASCIA
#9xl S.S.I.D. SCREW W/WASHER
T#194
#9x2" S,S.I.D. SCREWS AT EACH HI-RIB,
#gxl'1S.S.I.D. SCREWS CENTERED IN FLATS
KYNAR HI-RIB STEEL
IS TO END RAFTER W/HEADLOK SCREWS
#9x1" S.S,I.D. SCREW W/WASHER INTO F~CH PURLIN
(CENTERED BETWEEN HI-RIB AND FIRST MINOR RIB}
FLUOROFLEX HI-RIB STEEL
#9x2" S,S,I.D. SCREWS W/WASHERS INTO
PURLIN AT EACH HI-RIB
LS.I.D. SCREWS W/WASHER USED
TO STITCH LAP RIBS BETWEEN THE PURLINS
2x4 PURLINS
30' 4090 S.C, TRUSS
~ 128-0826 ~
II I
II I
7
~DRA WN 8¥: MOSIER
DATE; 11/13/08
CHECKED BY R.M.
DATE: 11118/08
REV/EEO DATE ---
REVISED DATE
REVISED DATE,' .--
/?EVL~ED DATE: .--
WINDBOURNE DEBRIS PROTECTION - WALK DOOR WALK DOOR SECTION IECALE; AS NOTEDSToFS10EHF~' ~vo.
2x6 NAILERS
--- LOWER ~HORD OF
30' 4090 S.C. TRUSS
y 7/16"OSB
_-51
EXTRA NAILERS ADDED
BETWEEN STD. NAILERS,,
[MAX. SPACE TO BE 24. )~
7/1 6" OSB SHEARWALL ELEVATION
SCALE: 1/2" = 1'-0"
CUPOLA ROOF
CUPOLA BASE TRIM --
VERTICAL BLOCKS @ ~
COLUMN BETWEEN NAILERS
GUN NAILS. NAILED 4" O.C.
~ LAMINATED COLUMN
RIMETER OF OSB SHEETS
NAILED W/1-3/4" RING SHANK
COIL GUN NAILS SPACED 4" O,C,
JLED TO INTERMEDIATE
SUPPORTS W/1-3/4" RING SHANK
COIL GUN NAILS SPACED 6" O,C.
LAMINATED COLUMN
5/4x6 NAILER
(IF PROTECTIVE LINER IS INCLUDED)
2x8 TREATED BASEBOARD
OSB SHEARWALL DETAIL
SCALE: 1/2" = 1'-0"
FIRST ROW
2x4 PURLINS
PEAK PURUN ~
CENTERLINE OF CUPOLA
1"0" 6" / 6" 1'-0"
FRAMING CLIP
TRUSS
FRAME
'OLA BASE FRAME ~
)SB CUPOLA SUPPORT
E BLOCK~
BLOCKS ~
, FRAMING CLIP~
3'6 x 3'6 Cupola Non-Functional
(2x4 Purlins)
39Q FRAMING CLIP~
CUPOLA FRAMING DETAIL
SCALE: 1"= 1'-0"
~ .3/16"x3/4"x30" H.R. FLAT STEEL
?
0.177'~-,25" STAINLESS STEEL
ANCHOR NAILS PER STRAP
BUILDING COLUMN
81M BASE A_NCH~OR FASTENING DETAIL
SCALE: I 1/2"= 1'-0"
CUTCHOGU E, N~Y .
OB NO.1
d
II I
7
~)RA WN B Y; V~OSIER
DA TE: 11 / 13/08
CHECKED BX {.M,
DATE; 11/18/08
REVISED DATE; ---
REVISED DATE: .-
REVISED DATE; .--
~EVI~ED DATE: ---
I $CALE:~8 NOTED SHEET NO.
oF Sl
KYNAR HI-RIB STEEL
30' 4090 S.C. TRUSS
T#71 TRACK COVER
51M TRACK
3x4 TRACK BOARD
TOP "D" RAIL (16 GUAGE) --
1 1/2"x2." BLOCK
T#74 TRIM
T#23 JAMB TRIM --
14'-0"
TRACK GIRT
TO GRADE
LATCH HANDLE --
47E A/S LATCH STRIKE PLATE --
2x3 JAMB JBEYOND;
BoTroM 2' TREATED)
SLIDING DOOR HEADER SECTION D
SCALE: 1" = 1'-0"
LATCH HANDLE
47E A/S LATCH STRIKE PLATE
HORIZONTAL INTERMEDIATE I RAIL
JAMB DETAIL
3-2X6 LAMINATED
JAMB COLUMN
(BEYOND)
Jill
GRADE
LAMINATED
JAMB COLUMN
DOUBLE TOP "b" RAIL
(16 GUAGE)
STRUT
HORIZONTAL 'T' S.S. RAIL
VERTICAL '1" RAIL
(0.06" WEB, 0.13" FLANGE)
HORIZONTAL "1" /
INTERMEDIATE RAIL
(0.06" WEB, 0.13" FLANGE)
VERTICAL "1" RAIL
(0.09" WEB, 0.1 $" FLANGE)
INTERMEDIATE DOOR GUIDE
7'-4 lJ~' ,j,
14'-9"
(0.09" WEB, 0.15" FLANGE)
LATCH HANDLE
DOUBLE BoTroM "D" RAIL
(16 GUAGE)
7'-4 1/2"
Illl
t
14'-0"
TRACK GIRT
TO GRADE
SINGLE SLIDING DOOR FRAME
[TWIN PANEL)
INTERMEDIATE DOOR GUIDE
DOOR GUIDE DETAIL
INSTRUCTIONS
1, SCREW NUT ONTO HOOK.
2. SCREW HOOK INTO LATCH BODY.
1265 JAMB LATCH BODY
LATCH HANDLE
CUTCHOGUE, N~Y _
d
II I
II I
7
Ll-I
n
n
II I
DATE: 11/13/08
CHECKED BY ~.M.
DATE: [1/1B/08
REVISED DATE: --
REVISED DATE: .--
EEVI$ED DATE: .-
REVISED DATE: ---
· SCALE: AS NOTED
SHEET'NO,
~ S9o,,: S10
! ROOF STRUCTURE FASTENING SCHEDULE
I
VENT-A-RiDGE TO BASE~ TRiM #9 x I" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS @ 8" o.c,
RIDGE BASE TRIM TO 2~4 PURLINS ~9 × 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'~' c.c.)
HI-RIB STEEL STITCHING J #9 x I" STAINLESS STEEl. RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS IN LAP RIBS BE"P/VEEN PURLINS
HI-RIB STEEl TO 2X4 pURLiNS #9 × 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-C~' o.¢.)
20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1" TRU-GRIP SCREWS
2x4 PURLINS TO TRUSS j HEADLOK 0.19"x6.C~" FLAIl-lEAD LAG SCREW
80, STRAiGHTCHORDi~RUSSTOCOLUMN (2J I/2"x5 I/2"M.BOLTS & (4) 0.177" x 4" [2Od) RING SHANK NAILS
' WALL FRAMING FASTENING SCHEDULE
COLUMN STILT ( 14 GAi) TO COLUMN J (12) 0,148,, x 2" (6d) STAINLESS STEEL RING SHANK NAILS
2x8 SPLASHBOARD TO/COLUMN J4) 0.177"x 4" (20d)STAINLESS STEEL RiNG SHANK NAILS @ SPLICE/IS)0.177" x 4" (20d)RING SHANK NAILS @ STANDARD CONNECTION
2x6 NOTCHED NAILER TO COLUMN (4) 0.177"x4" [20d) NAILS ~ SPLICE/J4) 0.177" x 4" J20d) NAILS @ STANDARD CONNECTION
7/16" OSB TO SPLASHBOARD & NOTCHED NAILER 0,099" x 1-1J4" ASBESTOS SIDING NAILS
2x6 NAILER TO COLUMN (4] 0.177,, x 4- (20dj RiNG SHANK NAILS @ SPLICE/(4] 0.177" x 4" (20d) RING SHANK NAILS @ STANDARD CONNECTION
4090 S,C. TRUSS TO 2x6 END COLUMN EXTENSION (4) 0.177" x 4" (20d) RING SHANK NAILS
2x4 PURLIN TO 4090 S,c. TRUSS .19'~(6,0" HI~ADLOK FLATHEAD LAG SCREW
HI-RIB STEEL TO NAILERS #9 X 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0"
iOFFIT TO WALL INSERTED IN PRE-FORMED SLOT iN SOFFIT/HI-RIB CAP
SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE
7/16" OSB SHEARWALL
OSB TO PERIMETER BLOCKS/FRAMING 0.113" xl-314" RING SHANK COIL NAILS @ 4"
OSB TO iNTERMEDIATE FRAMING 0.113" xl-3/4" RING SHANK COIL NAILS @ 6" C,C.
BLOCKS TO COLUMNS 0.131" x ;] 1/2" HOT DIPPED GALVANIZED (HDG) RING SHANK NAILS @ 4" o-c-
SCREWED ROOF STEEL CUPOLA FASTENING
CUPOLA CAP TO CUPOLA ROOF (4) 1/4"x I" PLATED MACHINE BOLTS AND LOCK WASHERS
CUPOLA ROOF TO CUPOLA SIDES PRE-FORMED CRIMPED METAL CONNECTIONS AND JB) #9 x 1" STAINLESS STEEL RUBBER WASHER EANHEAD INTERNAL DRIVE SCREWS
CUPOLA SIDES TO CU?OLA BASE FRAME #9 x 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS (4) PER SIDE J 16) TOTAL
CUPOLA BASE FRAMi TO OSB CUPOLA SUPPORT 1-7lB" GUN NAILS @ 6" c.c.
OSB CUPOLA SU PPOI~T TO TREATED BEVELED BLOCK 0.148" x 3-1/2" (16d) RiNG SHANK NAILS @ B" o.c,
TREATED BEVELED BLOCK TO 2x4 CUPOLA BLOCKS 1/4"x 4-112" LAG SCREW W/1/4" FLAT WASHER AT EVERY HI-RIB (1'-C~' c.c.)
2x4 CUPOLA BLOCKS/T0 FRAMING CLIPS (2] 0.135" x 1-1/2" RING SHANK NAILS
FRAMING CLIPS TO PURLINS (2) 0.135"x 1-1/2' RING SHANK NAILS IN SIDE OF PURLIN AND (2) 0.135" × 1-1/2" RING SHANK NAILS IN TOP OF PURLIN
PORCH FASTENING SCHEDULE
PORCH FRAME TOI PORCH COLUMN (1) 1/2~5 1/2' MACHINE BOLT & (6) 0.177"x 4" J20d) RING SHANK NAILS
2x4 PURLIN TO PORCH FRAME HEADLOK ,19x6.(~' FLATHEAD LAG SCREWS
USE JH20 ADJUSTABLE JOIST HANGER TO HEADER (2) #Rxl 1/2" TRU-GRIPS SCREWS & (12) 0.131" x 1 1/2" TC POSITIVE PLACEMENT GUN NAILS
USP JH20 ADJUSTABLE JOIST HANGER TO PORCH FRAME (6) 0.148" x 2-7J8" (1 Od) GALVANIZED POLE NAiL
USE MPA1 FRAMINGjCLIPTO 2x10 NAILER (6) #9xl 1/2" TRU-GRIP SCREWS
USE MPA1 FRAMING/CLIP TO PORCH FRAME (6) #9xl 1/2" TRU-GRIP SCREWS
IF?ICE':
CUTCHOGU~E, NY
OB NO,128-0826
n
n
7
DATE': 11/18/08
REVISED DATE,' ,--
10o S10 _.