HomeMy WebLinkAbout35644-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-34519 Date: 08/25/10
THIS CERTIFIES that the building ACCESSORY SOLAR PANELS
Location of Property: 85 SILVER COLT RD CUTCHOGUE
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 95 Block 4 Lot 18.1
Subdivision Filed Map No. __ Lot No. __
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JUNE 10, 2010 pursuant to which
Building permit No. 35644-Z dated JUNE 14, 2010
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The Occupancy for which this certificate is issued
is ACCESSORY SOLAR PANELS AS APPLIED FOR.
The certificate is issued to JOSEPH & BERNADETTE PETERSON
( OWNER )
of the aforesaid building.
SUFFOLK COUNTY DBPARTM~TP OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 35644 08/09/10
PLUMBERS c~KTIFICATION DA'i'~u3 N/A
Signature
Rev. 1/81
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 35644 Z Date JUNE 14, 2010
Permission is hereby granted to:
JOSEPH PETERSEN
85 SILVER COLT RD
CUTCHOGUE,NY 11935
for :
CONSTRUCTION OF ACCESSORY GROUND MOUNT SOLAR PANELS AS APPLIED
FOR
at premises located at
County Tax Map No. 473889 Section 095
pursuant to application dated JUNE
Building Inspector to expire on DECEMBER
85 SILVER COLT RD CUTCHOGUE
Block 0004 Lot No. 018.001
10, 2010 and approved by the
14, 2011.
Fee $ 163.60
Authorized 'Signature
ORIGINAL
Rev. 5/8/02
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTneICATE OF OCCUPAN~
This application mu~t be filled in by typewriter or ink and submitted to the Building Dep~
A. For new building or new use:
1. Final' surv0y of ProPea~ with accurate location of all buildings, property lines, str
topographic features.
Final ApprOval from Health Dept. of water supply and sewerage-disposal (S-9 form).
Approval of electrical installation from Board of Fire Underwriters.
'6.
Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead..
Commereial building, industrial building, multiple residences and Similar buildings and installations, a ce~fieate
of Code Compliance from architect.or engineer responsible for the building.
Submit Planning Board Approval of'~ompteted site plan requirements.
B..For ex~ting.buildings(pflor to April 9, 1957) non-conforming uses, or buildings and ,pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or tOpographic
features.
2. A pr°perly c°mpleted applieation and ennsent to ~nspeet signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in w~iting to the applicant.
C. Fees 1. Ceffificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00~ Additions to accessory building 325.00, Businesses $50.00.
2. Certificate of Occupancy on Preexisting Building - $100.00
3. Copy of Certificate of OcCupancy - $.25
4. Updated Certificate of Ocenpancy- $50.00
Temporary Certificate of Occupancy - Residential $15.01~, Commercial $15.00
· New Construction:
Location of Property:
House No.
OWner or Owners of property:.,
· Suffolk County Tax Map No 1000, Section
Health Dept. Approval:
Planning Board Approval:
RequeSt for: Temporary Certificate
Fee Submitted: $ ~._~.
Old or Pm. existing Building: (cheek One)
~-'~/"~ Filed Map...
Applicant:
Underwriters Approval:.
Final Certificate:
Toun ltall Anncx
51.375 Main Road
P.O. Box 117!t
Sottlhold. NY 11!~71-0!)59
Tc'k'llhonc (631) 765-1802
l:ax (631) 76,5-!1502
ro.qer, richert~,town.southold.ny.us
I½1 !ILDIN(; 1)EI'AI/TM I,~NT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Joseph Petersen
Address: 85 Silver Colt Rd. City: Cutchogue St: NY Zip: 11935
Building Permit #: 35644 Section: 95 Block: 4 Lot: 18.1
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Peterson Electric License No: 4102-me
SITE DETAILS
Office Use Only
Residential ~ Indoor ~ Basement ~ Service Only ~
Commerical Outdoor 1 st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Servicelph ~ Heat ~ DuplecRecpt ~
Service 3 ph Hot Water GFCl Recpt
Main Panel NC Condenser Single Recpt
Sub Panel NC Blower Range Recpt
Transformer Appliances Dryer Recpt
Disconnect Switches Twist Lock
Other Equipment: photovoltaic system
Ceiling Fixtures [~ HID Fixtures
Wall Fixtures ~.~ Smoke Detectors
Recessed Fixtures [~ CO Detectors
Fluorescent Fixture ~.~ Pumps
Emergency Fixtures[.~ Time Clocks
Exit Fixtures [~ TVSS
Notes: system consists of, 36 Trina 230 solar panels, 1 Sunny Boy 8000 inverter, sub panel, lac & 1dc disconnect
Inspector Signature:
Date: Aug 9 2010
81-Cert Electrical Compliance Form
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
/~FOUNDATION 1ST [
] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PEti,' ,.ATION
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]FIRE RESISTANT CONSTRUCTION
REMARKS:
DATE ~ -~ ~'~ '"-/0 INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ~ELECTRICAL (FINAL)
REMARKS:
DATE
INSPECTOR~
INSPECTION
[ ] FOUNDATION l ST [ ] ROUGH P~LBG.
[ ] FOUNDATION 2ND [ ]~ULATION
[ ] FRAMING / STRAPPING [ ~'J~FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS: ,~///~ ~//~ J
DATE ~J/~ //~) INSPECTOR__~~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
L
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown.NorthFork.net
Examined 20
Approved q/~, 20/O
Disapproved a/c
PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying'?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Expiration
5tuilding Inspector
Mail to:
~ [~ ~ ~ ~ ~ ~ ['~,('LICATION FOR BUILDING PERMIT
I~tl il[II Date_ (~:~ '"~2. ,20/O
. Thi~ ann ' ' _ .... :,.om >:tely filled in by t~ewriter or in ink and submitted to the Building Inspector with 4
of to sch au .
. P!:: p'.aX51;~,.,- -"-g location m lot"' ~nd of buildings on prmnises, relationship to adjoining premises or public streets or
areas, and wate~ays.
c. The work covered by this application may not be commenced before issu~ce of Building Pe~it.
d. Upon approval of this application, the Building Inspector will issue a Building Pemit to the applicant. Such a pe~it
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in pan for any pu¢ose what so ever until the Building Inspector
issues a Ceaificate of Occupancy.
L Evew building pemit shall expire if the work authorized has not commenced within 12 months aaer the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
propeay have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pemit for an
addition six months. Thereafter, a new pemit shall be required.
~PLICATION IS HEREBY MADE to the Building Depaament for the issuance of a Building Pe~it pursuant to the
Building Zone Ordinance of the Town of Southold, Suflblk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building lbr necessa~ inspections. -~ ~
( 'g~o~ap~ic~ name, ifa co¢oration)
~.~ t (Mailing address o,f..allplic.ant),~._
Stale whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises ~O,,~&
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on whicNoroposed wark will be d e:
House Number Street Hamlet
County Tax Map No. 1000 Section
Subdivision
Block Oq Lot /t (~:~'. l
Filed Map No. Lot
State existing use and occupancy of premises,, and intended use and occupancy of proposed construction:
a. Existing use and occupancy ~
b. Intended use and occupancy.
3. Nature of work (check which applicable): New Building_ Addition Alteration
Repair Removal Demolition Other Work V
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front
Height Number of Stories
Rear
Depth
Dimensions of same structure with alterations or additions: Front
Depth Height Number of Stories
Rear
8.. Dimensions of entire new construction: Front Rear
Height Number of Stories
9. Size of lot: Front Rear _Depth
Depth
10. Date of Purchase
Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO__
13. Will lot be re-graded? YES NO__Will excess fill be removed from premises? YES__ NO
14. Names of Owner of premises_~/"~f'-~-~'~ Address ~!~"' $,'/~ ~t~'"t"/~/.,,~lBne No. ~ ~ ! ".fl ~ &'"'"/~,J~
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO __
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO__
* 1F YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at '10 feet or below, must provide topographical data on survey.
18. Are ~here any covenants and restrictions with respect to this property? * YES __ NO ~
· IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF~4~
'~S--'~--~~' ~5~-----'~¢,_~ being duly sworn, deposes and says that (s)he is the applicant
(Name oY individual signing contract) above named,
(Contractor, Agent, Co¢orate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are tree to the best of his knowledge hnd belief; and that the work will be
Sworn to before me Otis
day ot~ ~
Notary Public
performed in the manner set forth in the application filed therewith.
nature of Applicant
Tow~ Hall Armex
54375 Main Road
P.O, Box 1179
Southold, NY 11971-0959
Telephone (631) 765-1801
r~er. richertL~,t~ (wn~.~gu~o~.ny. us
BUILDING DEPARTMENT
TOWN OF SOUTHOI.n
APPL[CAT[ON FOR ELECTR[CAL INSPECT[ON
) BY:
Company Name:
Name:
iPhone No.:
Date:
-/0
*Address:
*Cross Street:
*Phone No.:
Permit No.:
Tax Map District:
JOBSITE INFORMATION: (*IndiCates required information)
*Name: /~-/'~/ '
1000 Sectior{: . O~ Block: ~'~
*BRIEF~ESCRIPTIO~ OF WORK (Please Pdnt Clgady)
Lot:
(Please Circle All That Apply)
*Is.job ready for inspection:
*Do you need a Temp Certificate:
Temp Information (If needed) ·
*Service Size: 1 Phase
*New Service: 'Re-connect
Additional InfOrmation:
Rough In
Final
3Phase 100 150 200 300 350 400 Other
Underground Number of Meters Change of Service Overhead
PAYMENT DUE WITH A_ PPLICATION ~\ ~
82-Request for Inspection Form
OWNER
FORMER ~OWNER
TOWN OF SOUTHOLD
/2:, /
N
..,3 . .._,. S W
T DATE
PROPERTY- ,RECORD. CARD
VILLAGE
EuT~c,doy u ~'"
E
RES. ~:9 SFAS. CO~. C.. M,CS.
LAND IMP. RENI~RKS
/~00
TYPE OF BUJLDING
Mkt. 'alue
Tillable
~oodland
~eadowbnd
House Plot
Fotal
FRONTAGE ON WATER
FRONTAGE ON ROAD
DEPTH
BULKHEAD
Extend;on
Extension
. .F-.~er~ion
;~LOR ~J
TRIM VJ
Porch
Porch
Breezeway
Foundation
Basement
Ext. Walls
Fire Place
~,~Z.~"~ Type Roof
z~ ~.,/Recreation Room
~.7/¢~:3 Dormer
Bath
Floors
interior Finish
Heat
Garage ~-c~ xZ I = ,o~ z,o c~,~l.~._ %ams 1st Floor
Patio \ 'z- ~. \.~-= t,'/.& ,~;~ Rooms 2nd Floor
~ · Driveway/
Total
Dir~ette'
LR.
DR.
{BR.
IFIN, B
Tom~ I lall Annex
,5 ~375 Main Road
P.¢). Box 1179
Southold, NY 11971-095!1
Telephone (631) 765-1802
Fax (63 [ ) 765-9502
BI !ILl)lNG 1)EPAI/TMENT
TOWN OF SOUTHOLD
August 16, 2010
Joseph Petersen
85 Silver Colt Road
Cutchogue, NY 11935
TO WHOM IT MAY CONCERN:
The following items are needed to complete your Certificate of Occupancy:
~ Application of Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate.
~ Afeeof $25.00.
__ Final Health Department approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
__ Trustees Certificate of Compliance. (Town Trustees #765-1892)
__ Final Planning Board approval.
__ Final Fire Inspection from Fire Marshal.
__ Final Inspection from the Building Dept.
__ Final Landmark Preservation approval.
Building Permit: 35644-Z solar panels
J SU~Y F~:
dOSEPH PEIERSOS .
LOT I, "OREGON VIEW ESTATES MAYAU6 7,1985
I AT CUTCHOGUE OA~E, JAN 7,~98
I ~N ~ SOUTHOLD SC~E: ~"=50'
I SUFF~ ~TY, NEW ~ , ~. 84-1275
* I ~[Y Ia v~ M~C~ON ?Zoe ~ THE MET~ITAN
~ITLE
GUARANTY
I KW Y~K STA~ ~WTt~ ~
~ YOUNG YOUNG ~
Project IPetersen Elec
Quote DRB-LA-100503*t052
ProJe=t Ident: Petersen Eec Cuetomer: SUNation Contact: Mike Bailis Revision 0
Address1: Address: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Address2: Address2: Phone2:
City, ST, Zip: , 1t769 City, ST, ZIp: Oakdale, NY11769 Email: solardudelO25~aoLcom
ULA Geometry ~
TUna TSM-230-PA05
N-S Dim (In): 39.06 N-S Spacing (In): 1
E-W Dim (in): 64.69 E-W Sparing (in): 0
Thickness (in): 1.81 Power Rating (W): 230
Orientation: L Weight (lbs): 43
# Rows: 4 Column N-S Length (in):
# Columns: 9 Array E-W Dlmer~on (in):
SubArray Modules: 35 Array N-S PmJecUen (in):
Rails Per Module: 2
Extended Rail (In): 3
161 # SubArrays:
582 Total Modules: 36
164 ULA Power Rating CkW): 8.28
NOTiF~ BUILDING DEP~:",,it~-----~ ......... ~ 9_._,.~
765-1802 8 AM TO 4 ,,~ FOR DiE] ~ 86.0
FOLLOWING INSPECTIONS I
1. FOUNDATION- T~ REQUIRED ~, .~A~y~roj~n
FOR POURED CO~
2, R~H- F~I~. ~,
ST~ING. ELEC~ICAL & CAULKING
3. I~
4. FINAL- CONSTRUCT!0~ g E~EC '~ICAL
MUST BE COMPLET~ F~ C O ~ ,
ALL CONSTRUCTION SHALL MEET THE
REOUIREMENTS OF THE CODES OF NEW ' '
STAre, FOR
DESIGN ~ ~m~ E~S. f~g ¢' ' .....
Monday, May 03, 2010
Rail Length (In): AD 164 164 In
Tilt Angle (deg): O 30 30 degrees
Rail Span: BC 98.4 99.3 In
Rail Overhang: AB, CD 32,8 32.35 in
Front Edge Height: AE 28 28 in
Rear Edge Height: DH 110 110 in
Front Leg Length: BF 44.4 44.18 in
Rear Leg Length: CG 93.6 93.83 in
N-S Cross Brace Lellgth: BG 148.81 96.b ,n r-~ ~
N-S Cross Brace Angle: I~ 17.36 27.1! degree~Z ~
N-S Leg Spadng:~~~r~ . 142.03 86 --~ ~c_. ]~
· e., '/,.~xv .,~.. '~.\'~ ~ ~ ~ I ~ I
]~ngineeri~g Re~H- Page 1 of 11
Project IPetersen Elec I Quote DRB-LA-t00503-1052
Project Ident: Petersen Elec Cuetomer: SUNation Contact: Mike Baitis Revision 0
Addreeal: Address: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Addreae2: Addreas2: Phone2:
City. ST, Zip: , 11769 City, ST, Zip: Oakdale, NYl1769 Emaih solardude1025@aoLcom
Wind Load Calculations ~
Tilt Angle (deg]: 30
Array Height above ground: 0
Exposure Category: C
Basic Wind Speed, V (mph): 120.00
Imbortanoe Factor: 0.87
Roof Zone Multiplier: I
qn = O'O0256K, K,tKaV21(lb / fl2)
Adjustment Factor for height and Exposure Category Kz: 0.85
Topographic Factor (assumed to bo I for level ground) Kzt: 1
Directionality Factor Kd: 0.85
Wind Load (ps~ qh: 23.17
Uplift Down Force
Front Leg: -35.45 Front Leg: 51.21
Rear Leg: -49.24 Rear Leg: 41.36
Load Caoa A Load Case B Load Case A Load Case B
Front Leg -1,8 -0.5 2,1 2.6
Rear Leg -1,8 -2.5 2.1 1
Average -1.8 -1.5 2,1 1.8
Gust Effect Factor (G): 0.85 p = qnGCn
Load Case A Load Case B Load Case A Load Caea B
Cn (Front Leg): -3SAS -10 41.36 51.21
Cn (Rear Leg): -35.45 -49.24 41,36 19.69
Cn (Avg): -35.45 -29.54 41.36 35.45
Monday, May 03, 2010 Engineering Report - Page 2 of l I
Project IPetersen Elec I Quote DRS-u~4ooso3-~0s2
Project Ident: Petarsen Elec Customer: SUNation Contact; Mike Bailis Revision 0
Addresel: Addres.: 1217 MontaukHwy Phone: 631-750-9454 Preparer danb
Address2: Addrese2: Phone2:
ClbJ, ST, Zip: , 11769 City, ST, Zip: Oakdale, NYl1769 Email: solardude1026~aoLcom
Combination Load Analysis ~
Dead Load: 6.06 Assumed
Snow Load: 5.7
Down Force Uplift
Front Leg: 58.21 -31.25
Rear Leg: 48.36 -45.04
Ma~ (Absolute): 48.36
Dead Snow Wind
Load Load Load
Load Case 1 (downforce): 1 I 0
Load Case 2 (downforce): I 0 1
Load Case 3 (downforce): I 0.75 0.75
Load Case 4 (uplift): 0.6 I
Wind Load Wind Load
Case A Case B
Load Case 1 (downforce): 12.7 12.7
Load Case 2 (downforce): 48.36 58.21
Load Case 3 (downforce): 42.3 49.68
Hax Downforce: 48,36 58.21
Load Case 4 (upl~): -31.25 -5.8
Wind Load Wind Load
time A Case B
Load Case 1 (downforce): 12.7 12.7
lead Case 2 (downforce): 48,36 26.69
Load Case 3 (downforce): 42.3 26,04
Hax Downf~rce: 48.36 26.69
Load Case 4 (uplift): -31.25 -45.04
Monday, May 03, 2010 Engineering Report - Page 3 of I I
Project IPetersen Elec I Quote o.S*LA.~o0so3-*os2
Project Ident: Petersen Elec Cuetomer: SUNation Contact: Mike Bailis Revision 0
Addmsat: Address: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Addreaa2: Address2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NYl1769 Email: solardude1025~aol.com
I Ho~l~on~l Pil~ D~i~n
I'i'l'l~' ........ i'lr
Pipe Span (E-W Leg Sparing): 60
Number of Leg Pairs: 10
Horizontal Pipe Overhang (in): 20.07
Front Leg (pst): 58.21
Rear Leg (pst): 48.36
Maximum absolute value of
Load ComblnaUon Loads
582
Pipe Selec~on: 2 in. Schedule 40
Modulus of Elasticity, E (psf): 4.18E+09
Moment of ~nta~a, ! (ft^4): 0.0000302
Secl:lon Modulus, Z (fi^3): 0.000413
Yield Stress, Fy (psf): 5040000
Anay Wicl~ (In): 582
Rail Length (In): 164
Max Distributed Load (pit):
Pipe Span (in):
Nlowable 8ending Moment (lb-R):
Actual Bending Moment (lb-R):
Actual/Allowable Moment:
Nlowable Total Deflection LJ70 (in):
Actual Deflection (in):
Actual/Nlowable Deflection:
Max Revised Max Revised
390.49 390.49 324.42 324.42
60.64 60.21 60.64 60,2!
].246.42 1246.42 1246.42 1246.42
1246,45 1228.84 1035.56 1020.92
10o% 99% 03% 82%
0.87 0.86 0.87 0.86
0.32 0.31 0.26 0.2S
37% 36% 30% 29%
Monday, May 03, 2010 Engineering Report- Page 4 of I 1
Project [Petersen Elec ] Quote O,,.LA.~OOSO3.~O,2
Project Ident: Petersen Elec Cuetomer: SUNation Contact: Mike Bailis Revision 0
Addreaal: Addreu: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Adding2: Addrose2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NYl1769 Emeil: solardude1025@aol.com
IR al, Bending ~
Rail Length (In): 164
Rail Overhang (In): 32.35
Rail Span (in): 99.3
,~.;; ..~.,.,.~, ......... iiq-iifllli~11['l
Maximum Average Design Load (psiS: 48,36
Module Dim Perpendicular to Rails (in): 64.69
Rails Per Module: 2
DIst~buted Load (plf): 130.35
Ratl Selection:
SolarMount HD
E (psf): 1.45E+09
! (fi^4): 0.0000697
Z (re^3): 0.000522
Fy (pst): 2736000
Allowable Bending Moment (lb-R): 1428.19
N:tual Bending Moment (lb-E): 1115.73
Actual/Allowable Moment: 78%
Allowable Deflection (In): 1.41
Actual Deflection (In): 0.94
Actual/Allowable Deflection: 67%
Monday, May 03, 2010 Engineering Report- Page 5 of I I
Project IPetersen Elec I Quote
Project Ident: Petersen Elec Cuatomer: SUNation Contact: Mike Baitis Revision 0
Addreeal: Addreas: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Addrea$2: Address2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NY11769 Emeil: solardude1025~aol.com
Force Analysis ~
'1
'Tilt Angle (deg):
Cross Brace Angle (deg):
E-W Leg Sparing)
Rail Length:
3O
27.19 Front Leg (psf/Up):
60
164 Rear Leg (psf/kip):
li'lllq'fl'
Downf~rce Uplift
58.21 2 -31.23 -1.07
48.36 1.66 -45,04 -1,54
Down Force Uplift
Axial Force In Front Leg: 1.73 -0,93
Axial Force In Front Cap: 3,73 -1.47
Shear Force Front Cap: 2 Max Magnitude
Axall Force In Rear Leg: 1.44 -1.33
Axial Force In Rear Cap: 0.61 -0.56
Shear Force Rear Cap: 0.83 Max Magnitude
Shear Force Rear Foot: 2 Max Magnitude
Axial Force In N-S Brace: 2 -0.54
Resultant Shear N-S Brace: 1.78 Max Magnitude
Resultant Axial N-S Brace: 0,91 -0.25
Axial Force Rail: 0.83 -0,77
Resultant Shear Rail: 0.42 Max Magnitude
Resultant Axial Rail: 0.72 -0.67
Monday, May 03, 2010 Engineering Report - Page 6 of 11
Project IPetersen Elec I Quote
Project Ident: Petersen Elec Customer: SUNation Contact: Mike Bailis Revision 0
Addreeel: Addmee: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Address2: Addreel2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NYl1769 Email: soiardude10251~aoLcom
Column Buckling Analysis
Pipe SelecUon: Pipe Selection: ! [ Rail Se~Uon:
2 in. Schedule 40 2 In. Schedule 40 i [ SolerHount HD
I E (ksi): 10,1
E (ksl): 29 E (ksi): 29 '
Fy (ksl): 19
Fy (kst): 35 Fy (ksl): 35
r (in): 1.1679
r (in): 0.791 r (in): 0.791 Palls per EW Leg: 1.86
Length: 44.18
Eft. Column Len. Fac: 1
Eft. Column Length: ,H.18
Slenderness Patio: 55.85
Critical Force: 17.87
Actual Force: 1.73
PaUo To Allowable: 9.68%
Length: 93.83
Eft. Column Len. Fac: 1
Eft. Column Length: 93,83
Slenderness Ratio: 118.62
Critical Force: 10.22
Actual Force: 1.44
Ratio To Allowable: 14.09%
Length: 9g,3
Eft, Column Len, Fac: 1
Eft, Column Length: 99,30
Slenderness Ratio: 85.02
Critical Force: 7.49
Actual Force: 0.83
Patio To Allowable: 11.08%
Cross Brace Selection:
2" x 2" Aluminum Square Tube
E (ksl): 10.1
Fy (ksl): 19
r (in): 0.7672
Length: 96.68
Eft. Column Len. Fac: 1
Eft. Column Length: 96.68
Slenderness Patio: 126,02
Cdflcal Force: 3.01
Actual Force: 2
Ratio TO Allowable: 66.45%
Monday, May 05, 2010 Engineering Report - Page 7 of l l
Project [Petersen Elec I Quote DRB-LA-t00'03-10'2
Project Ident: Petersen Elec Customer: SUNafion Contact: Mike Bailis Revision 0
Addreeel: Address: 1217 Montauk Hwy Phone: 631.750-9454 Preparer danb
Addrele2: Address2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NY11769 Email: solardude1025@aol,com
Seismic Design and Analysis ~
Latitude: 0 ASCE7-OS
Methodology
Longitude: 0
Site Class: A
Importance Factor: 0
Roof Height: 0
Component Height: 0
Ss: 0 Mapped Accel. Parameter
S1: 0 Mapped Accel. Parameter
Fa: 0 Table 1613.5.3(1)
Fy: 0 Table 1613.5.3(2)
Sm$: 0 Eq # 16 -37
Sm1: 0 Eq # 16 - 38
Sds: 0 Eq # 16 -39
Sd1: 0 Eq # 16 *'40
Ap, Rp: 1.0, 1.5 Table 13,6- 1
Fp LRFD: 0 Eq 13.3 - 1
Fp ASD: 0.33 per 13,1.7
- OR - Seismic Zone: II! Direct Methodology Fp ASD: 0,33
Cross Brace Pairs: I
Array Weight: 4640
Total Axial Force: 1531.15
lbs
Cross Brace Selection:
2' x 2" Numlnum Square Tube
E (kst): 10,1
Fy (ksi): 19
r (in): 0.7672
Area (SCl in): 0.9375
Max C8 Length: 111,49
Eft, Column Lea. Fac: 2
Eft. Coiumn Length: 222.98
Slenderness RaUo: 145.32
Critical Force: 3.01
Actual Force: 0.77
Margin Ratio: 25.6%
Kip
Kip
Monday, May 03, 2010 Engineering Report - Page 8 of l l
Project IPetersen Elec I Quote M.,-L~I00S03-~0Sa
Project Ident: Petemen Elec Customer: SUNation Contact: Mike Bailis Revision 0
Addree$1: Addrese: 1217 Montauk Hwy Phone: 631-750-g45~ Preparer danb
Addren2: Addrem~2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdele, NY11769 Email: sotardude1025~aoLcom
Footing Design lm]im.l~a
Footing Diameter: 18 irt,
Footing Depth: 42 lo,
Concrete Density: 0.15 Ko'
Soil Dersity: 0.1 KeF
Max Uplift Force: 1,33 lOp
Safety Factor: 1.67
Required Resisting Force: 2.22 Kip
Concrete Volume: 6,19 cf
Concrete Weight: 0,93 Kip
Soil Volume: 63.26 cf
Soil Weight: 3.16 lop
Total Welgh~: 4,09 Kip
Margin RaUo: 54,31%
INFORMATION
ONLY
NOT TO BE USED FOR
CONSTRUCTION
Pier
Height
Pier
Diameter
Monday, May 03, 2010 Engineering Report- Page 9 of l l
Project IPetersen Elec Quote DRB-LA-100503-1052
Project Ident: Petersen Elec Cuetomer: SUNation Contact: Mike Bailis Revision 0
Addreael: Address: 1217 Montauk Hwy Phone: 631.750.9454 preparer danb
Address2: Address2: Phone2:
City, ST, Zip: , 11769 City, ST, Zip: Oakdale, NY11769 Email: soiardude1025~aol.com
Cap and Foot
Design
Cap Selection: Aluminum- 2" Front Cap
Pipe Selection: 2 In. Schedule 40
Compressfon Tension Shear
(kip) (kip) (kip)
Allowable: 7272 -2.4 2,424
Actual: 3,73 -1.47 2
Margin Ratio: 51,29% 61,25% 82,51%
....... iriYll'
Axial Axial
Compression Tension Shear
(kip) (kip) (kip)
Actual: 3.73 -t,47 0
Cap Selection: Aluminum- 2" Front Cap
A~al Axial
compression Tension Shear
(kip) (kip) (kip)
Allowable: 7.272 -2.4 2,424
Actual: 1.44 -1,33 0.8:3
Margin Ratio: 19,80% 55,42% 34.24%
Axial Axial
compression Tension Shear
(kip) (kip) (kip)
Actual: 1,44 -1.33 2
Monday, May 03, 2010 Engineering Report - Page I0 of I I
Project IPetersen Elec ] Quote rms-gAnoOso3.~o52
ProJect ldent: Petarsen Elec Customer: SUNation Contact: Mike Bailis Revision 0
Addreut: Addroaa: 1217 Montauk Hwy Phone: 631-750-9454 Preparer danb
Address2: Address2: Phone2:
City, ST, Zip: , 11769 City, ST, ZIp: Oakdale, NY11769 Email: solardude1025(~aol.com
~Deslgn Margin Ratios
Horizontal Pipe: 2 In, Schedule 40 I Rail Selection: SolarHount HD
Front Rear I I Rail Bending Moment: 78%
Pipe Moment: 99% Pipe Moment: 82%
Rail Bending Defied:Ion: 67%
Pipe Deflection: 36% Pipe Deflection: 29%
Rail Buckling: 11.08%
Front Leg Bucklllng: 9.68%
Rear Leg Bucklllng: 14,09%
N-S Brace Buckling: 66.45%
Cap Selection: Aluminum- 2" Fn:mt Cap
Front Rear
Axial Compression: 51,29% Axial Compression: 19,80%
AxIal Tension: 61.25% AxIal Tension: 55.42%
Shear', 82,51% Shear: 34.24%
Margin Ratio: 25.6%
Monday, May 03, 2010 Engineering Report - Page II of l I