Loading...
HomeMy WebLinkAbout34232-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34511 Date: 08/23/10 THIS U~K'rIFIES that the building ADDITION/ALTERATIONS Location of Property: 350 BROOK LA SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map NO. 473889 Section 79 Block 5 Lot 16.6 subdivision Filed Map No. __ Lot NO. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated OCTOBER 9, 2008 pursuant to which Building Permit No. 34232-Z dated OCTOBER 15, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS AND ADDITIONS, INCLUDING ATTACHED TWO CAR GARAGE AND COVERED PORCH, TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to ERNEST V & CARMELA LAZIO JR (OWNER) of the aforesaid building. S~FOIu~ ~)~ DEP~/~qT OF HFu%LTH APPROVAL R10-07-0044 EI~Ci-KIC~ ~TIFICATH NO. 08-8980 PLU~ERS CERTIFICATION DATED 03/04/10 JOHN ESTABROOK 03/01/10 12/23/09 Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34232 Z Date OCTOBER 15, 2008 Permission is hereby granted to: ERNEST V & C~RMELA LAZIO JR 350 BROOK LANE SOUTHOLD,NY 11971 for : 38.5X84 TWO STORY ADDITION/INTERIOR/EXTERIOR ALT, FRONT&REAR DECK ADDITIONS, 4 CAR ATT'D GAR3LGE TO EXISTING SFD AS APPLIED FOR. 6 BDRM PER SCHD at premises located at 350 BROOK LA SOUTHOLD County Tax Map No. 473889 Section 079 Block 0005 Lot NO. 016.006 pursuant to application dated OCTOBER 9, 2008 a~d Building Inspect°r t° expire °n APRI ~~15' 2010'~ Fees 3,794.80 ~~ ~Lgna~'~- ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be fired ia by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. Commerc'ial building, iaduatrial building, multiple residencea and Similar buildings and installations, a Certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existingbuildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, thc Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. Certificate of Occupancy on Pre-existing Building - $100.00 ~. Copy of Certificate of Occupancy - $.25 Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 -New Construction: Location of Property: 3~C~ House No. Owner or Owners of Property: · SUffolk County Tax Map No 1000, Section Subdivision Date. Old or Pre-existing Building: Street Permit No. /9)q ~ .~5~)~.~ Health Dept. Approval: Planning Board Approval: _ (check one) Block ~-- Filed Map. Date of Permit. ~(.~//[.~/0~ Apphcant: Unde~te~ Appm~: Request for: Temporary Certificate Fee Submitted: $ Lot Lot: Final Certificate: ~ (check one) ~icant Signature Electrical Inspectors, Inc. 308 East Meadow Avenue East Meadow, NY 11554 Offi¢¢: (516) 794-0400 (631)396-7474 Fax: (516) 794-5854 Website: www.electriealinspectors.cora Email: info~lectricalinspect~mcom Mail To: Pinti.Electric Vincent Pinti 36 Colonial Street East Northport, NY 1173l Licensed: 33025-ME Certificate Number: 08-8980 Municipality: Southold, Town Of Inspector., 124 lssue Date: 12/23/2009 Property Address: Emie Lazio 350 Brook Lane Southold, NY 11971 ELECTRICAL APPROVAL CERTIFICATE AREAS LISTED BELOW ARE APPROVED BY INSPECTION AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE No visual defects were found for the electrical inspection provided. No obvious unsatisfactory conditions were found in the mas herein below only. Residential Inspection Basement~' 2 Storage Rooms tst Floor., 2 Bathrooms, Deck, Foyer, Hall, Kitchen, Pant~. Porch, Watk-ln Closet, Mud Room, Great Room, Bar ROOm, Media Room. Audio Closet 2nd Floor: 2 Bathrooms, 2 Bedrooms. Hall, Laundry Room, Master Bathroom. Master Bedroom, Sitting Room, 2 Walk-ln Closets Attic: Storage Room 4 Car Attached Garage 132- Duplex Receptacles. 23- GFI Receptacles, 6- Single Receptacles, 1- 20Amp Appliance Receptacle, 1- Floor Receptacle, 94- Switches, 1- 40Amp Oven, 1- Dishwasher, 168- Recessed Fixtures, 7- Paddle Fan Outlets. 26- Incandescent Fixtures. 14- Wall Sconces, 7- Exhaust Fans, 3- 30Amp A/C Condensors, 1- 40Amp A/C Condensor, 1- 50Amp A/C Condensor, 5- 20Amp Blowers. 14- Fractional Motors. 1- 20Amp lnsta Hot Water Heater, 3- CO Alarms. 22- Fluorescent Fixtures, 1- Transfer Switch, 1- Steam Unit 50Amp. 1- Hydro Tub. 400Amp Single Phase Underground Service Upgrade/CB/l Meter, 200Amp Single Phase Main Panel/4OCkts/40 Used, 200Amp Main Panel/4OCkls/40 Used. l OOAmp Single Phase Sub Panel/20Ckts/2 7 Used. * Rough 6/15/09 Final 12/22/09 *Note' Smoke Alarms By Others, Not Part of This Inspection or Certificate Richard M. Bivone President ~ j Not va~d unless signed by an Chief Electrical Inspector [ · / I. EIA~',CTRI( Al. INSPECTORS. INC. r, not ~e.,pon',ihlc for the exNin~ condiom~ at the subject premi',e',. 2.. EI,I:ATI'RICAI, INSPECTORS, INC. i~ nul rc~,ponsilqc Ik>l correctionx, up,lading or ~cplaccmcnt of cxb, lin~ electrical; halations at the subject prcnlisc,,. Any colrccti,,c ,,,.et k ',hall be solely thc responsibility of thc properly ov, nei EIA'2CTRICAL INSPECTORS, INC. DOES NOT ~t, ARRANTY OR UNDERWRITE THE EI~ECTRICAI~ CONDITIONS AT THE PREMISES. 3. ELECTRICAl. INSPECTORS, IN(. only iccofmze~, lhe National klccllic ('ode. thc Building ('odes of Ncx~ York State all x olume~ and I.ocal Municipal ('ode~. as Mithorizcd by 'lhe I)epartmcnt of State ('odch Division. via Village, To~kn et City Bored Rc~ohtlion 4. AN ELECTRI(!AI. SURVEY consists el a ,,isual exanlinalion <>f the prcnlise', ()NI.Y: Elcct]'ical Inspectnrs Inc. will comply with thc ictjui['elllellls el NFPA 73, latc~t edition Chaptc~ 1. ~eclion J I. I 2. Il violations exis[, a Notice of Violalion (NOV) will be issued rcqtming ctn rection by a licensed electrical contractor. Aftc~ violation h:ts been c{nl'ectcd, a i'c-i]lspection xxill be omducicd and il apln'Ox cd a certificate shall be i~sucd 5. A SURVEY CERTIFICATI,; docs not examine the actual v, iring2 o~ dc', icc~, units*, all v, alls are opened and wires and dcx ices mc exposed prior to thc htlrxey bein~ ¢ollducled. 6. A CERTIFICATE is non-tlanslelahle 7. AN ELE(?TRICAL INSPECTION cow, isis et an cxaminatitm ol x,,iriug and in~,lallations dui mg the rotlgh stzt~t's o1' conMiuclioll ~Hel ColnpJction oJ thc O)IlM1LiCLi(~I/ zt J~JJlaJ Hlspt'CdOll will he conducted al which tilllc a ccltilicatc xxiJl be issued prox idcd no x iolation c'xist In thc cx t'nt no lllnpeclion is iPqtleStt'd during file i'nngh Magcs el conMiuction EIA~CTRICAI. INSPECTORS, INC. will pcrhnm a CIX)SED WAI.L SURVEY that consists ora visnal inspection of Ibc XQl'ing and inMallations only Since z~ccess is limited. ELECTRICAl, INSI~ECTORS, INC. shall bear no responsibility lot an} dottels or kioJzlliOI/s Lit the premises. 8, EI,ECTRICAL INSPECTORS. IN(/, shall not bc respculsihle to rcmo~,c any walls in ilrder t(i conduct an electrical mspecti(m. 9. EI.ECTRICAI. INSPECTORS, IN(?. ',: ill tmty release infoHnation, ccrtilicale,, m~d ~cpolts to the applicant after payment titr SClViCC'4 [cndeted haxc bccn paid in tull 10. F:LECTRICAI~ INSPECTORS, INC. assumes no liability Ikn the results ol its ]nspcclions. The ag]'eement may not bc changed olall~. Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 BUILDING DEPARTMENT TOWN Ol* SOUTI-IOLD CERTIFICATION Telephone (63 l) 765,1802 Fax (631) 765-9502 Building Permit No. C~CJ ~ '~ ~, ~__ Owner: (Please prMt._~) Plumber: ///L~ ' ~--""-~-~//'L~ (Please print) lead. I certify that the solder used in the water supply system contains less than 2/10 of 1% ?&lumbe~r~ s Signature) Sworn to before me this z/' day of//~dE'd~ , 20/,~ Notary Public, & ~'~=:~/". County BRIAN J. HUGHES l'(otary Public, State of New I~o. 02HU4863487. Qualified in Suffolk County Commission Expires June 2, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ~'~FOUNDATION 1ST [ [ ] FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST ~FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ]INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR ~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FO~TIONIST [ ]ROUGHPLBG. [ ~UNDATION2ND [ ]INSULATION ~,/] FRAMIN~~~______~G~ ] FINAL [ ] FIREPLACE &~ [ ] FIRE SAFETY INSPECTION ] RRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: f/~tT~ , ~'/'~-~..~/~ c.}'~_.,~ ~__ DATE INSPECTOR//~~/~~/ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOU~ii~ATION 2ND [ ] INSULATION [~/F~F~MING/~ [ ] FINAL [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ REMARKS: '~;"'//~ /d~-1~ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 ' "SPEC RTo~uG. pL.NG, [ ] FOUN?~ATION 1ST [ ] F/OUNDATION 2ND [ ] INSULATION [/]~ FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTAI~I' PENETRATION REMARKS: ~//'~, ~/-~--~(-~--~ ~/~--~ DATE ~'~/r/~ INSPECTOR-~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION REMARKS: ~ROUGH PLBG. [ ]INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION INSPECTOR~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] .~aHPLBG. [ ] FOUNDATION 2ND [//]/INSULATION [ ]FRAMING/STRAPPING []FIREPLACE&CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION REMARKS: [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION DATE ~~/I(~')? INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS~L-4~ION [ ] FRAMING / STRAPPING [~3'"FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTAI~I'_ CONSTRUCTION [ ] FIRE RESISTANT PENETR~TION REMARKS./~~ DATE INSPECTOR ~ , TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ] IN/SULATION [ L,~INAL [ ] FIRE SAFETY INSI~=CI'ION [ ] FtRERES~TAm'CONSTmJcflON [ ]RRERES~r~U~T~ET~T~N REMARKS: DATE 12WSPECT][ON REPORT ] DATE COMIViENTS FOUNDATION (1ST) FOL_~DATION (2ND) ROUG/~ FP._~vlING & pL~.qvfl~l~ G [NSIYLATION PER N. Y. STATE ENERGY CODE FLNAL TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined Approved t (' ~ i ~ -~ ,20 ~"xo Disapproved a/c Expiration PERMIT NO. ~t~ ,~ 3 ~ ' bLDG. DEPT I BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the foll,°~g, before applying'? Board of Health v 4 sets of Building Plans ~ Planning Board approval Survey ~" Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: L~-i 0 Mailto:'~o~O qSrooL GoJe- Phone: 7(0 5 - ¢77 g Building Inspector APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~ ?~n~_~/~l~ic ant ~o r~d.~e, if a corporation) /Iq-1/ (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises ~tFUlx°~/- b/ 6;gqd ~rF~ ~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders LicenseNo. Plumbers LicenseNo. Electricians LicenseNo. Other Trade's License No. Location of land on which proposed work will be done: 3'50 'bv'o oL OmJe. ;5o q4-,o mOl House Number Street 4- County Tax Map No. lO00 Section ]000-7c} Block Subdivision 1(9 1 Hamlet -o5 Filed Map No. Lot State existing use and occupancy of premises, and intended use and occupancy of proposed construction: a. Existing use and occupancy -7~t'~ t. JO.4e_, dCt,~[I/r~ b. Intended use and occupancy .~)/~ L)~,/e_ C{.~I t'/~ Nature of work (check which applicable): New Building Repair Removal Demolition Addition Other Work 4. Estimated Cost q(~O t 000 Fee Alteration (Description) · (To be paid on filing this application) 5. If dwelling, number of dwelling units NH_tuber of dwelling units on each floor If garage, number of cars 4' ~ *~ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of_existing structures, if any: Front r0 q. ~r Rear r') (4. ~/ Height ~ ~. ~L Number of Stories ~,~ Dimensions of same structure with alterations or additions: Front Depth 5(0, ~' Height ~3,Q.c/ Depth~Q,~'- ~ 7¢ '4 Rear Numberof Stories ~ Rear .Depth 8. Dimensions of entire new construction: Front Height Number of Stories 9. Size of lot: Front ~) Rear oQ ~ ~ 10. Date of Purchase (O ]O/G Name of Former Owner _Depth 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO v" 13. Will lot be re-graded? YES__ 14. Names of Owner ofpr. emises ~(rr',~ L.~'"g~o Addressee N~eofArchitect ~ * ~ Addressl~q Nme of ConWacto~ ~ ~ Address NO Will excess fill be removed from premises? YES__ Phone No£~// Phone No (9 ~-'~ '- Phone No. ,~3 15 a. Is this property within 100 feet ora tidal wetland or a freshwater wetland? *YES * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO__ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES · IF YES, PROVIDE A COPY. NO STATE OF NEW YORK) COUNTY OF~?~4~a~)S: ~/~tl/(.4~'7-' ( /4} P_, t 0 being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. BRIAN. J- HUGHES S w °~m~'~b e -f° r:a~n;/'~./~__/20Of(~,/~b .~~ ~otary Public, State of New .~r~ No. 02HU4863487 . (~u&lified in Suffolk,O,~l~o~r~ (~ Commission' Expires Ju~.,,,~ ~. Signature o f'~pplicant Town of $outhold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FOI1N! PROPERTY LOCATION: S.C~T.M. #: __ OL~_~_- 7~ --C,'~-I~.~(.' TNEFOLLOWINGACTIONSMAYREQUIRBTNESUEMiSSiONOFA STORM-WATERI GRADING~ DRAINAGE AND EROSION CONTROL PLi~ oistrict $ec[io, alack Lo[ CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATF-OF NEW YOik, Item N unlber: (HOTE; A Check Mark (4) for each Question is Required for a CorupleIe Application) Yes ~e 1 Will this Projec( Retain All Storm-Waler Run-Off Generated by a Two (2") Inch Rainfall on Site? (This item will include all run-off, created by site clearing and/or construction aclivities as we~l as all Site Improvements and the perruanent creation of irupervious surfaces,) 2 Does the Site Plan and/or Survey Show All Proposed Drainage S{ructures Indicating Size & Location? This Item shall include all Proposed Grade Changes and Slopes Con~rulling Surface Wa[erFIow! 3 Will Ihis Projecl Require any Land Pilling, Grading or Excavation where there is a change to ihe Natural r~ E×isting Grade Involving more than 200 Cubic Yards of Matedal within any Parcel? 4 Will this Application Require Land Disturbing Activities Encompassing an Area iq Excess of F*"~ / Five Thousand (5,000) Square Feet el Ground Surface? 5 Is ti,ere a Natural Water Course Running ihrough the Site? E~ / Is tfiis Proiect within the Truslees jurisdFction or within One Hundred (100') feel of a We[ and or Beach? 6 Will there be Sde preparation on Exisling Grade Slopes which Exceed Fiffeen (15) feel of Verfica[ Rise (o ~ / One Hundred (100') of Hodzorltal Distance? inlo and/or in the direction of a Towa dght <d way? NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark in the Box, a Storm-Water, Grading, Drainage & Erosion Control Plan is Required and Must be Submitted for Review Prior to Issuance of Any Building Permit! EXEMPTION~ Does this project meet Ihe minimum standards for classification as an Agricultural Project? Ye~s Note: If You Answered Yes toth[s Question, aStorm-Water, Grading, Drainage & Erosion Controi Plan is NOT Required! STATE OF NEX,¥ YOILK, count, 5E k! 7 ........ ,ss Owner aad/o]- represelibiUve of fl~e Owner of Owller's, ~ld is duty aud~orized Io perform or have pet-forrued d~e sad work a~d to lille a~d file this application; flaat MI satemenbs conained m this applicaNon are ~e to ~le best of his M~owledge a~(l belief; ~at tiaa work will be pel'formed in the Illmner set forfl~ in ~e applica~on filed herewifl~. S~l'om Io before rue ~is; ao~ry Pub c' ~~~ BRIAN J HUGHES~ ~ No. OaHU4863&~7 FORM- 06/07 qualifie~ in suffolk counW ._ Commission Expires June ~, 2~ (O(-.)O--'7'9- ~ - 14~. ~ TOWN OF SOUTHOLD PROPERTY RECORD CARD STREET .~,_¢:~/ ~'~ VILLAGE DIST. SUB. LOT ~) , ~RMER OWNER N E ACR. ) ~ra~,' o.9~ I , LAND IMP. TOTAL DATE REMARKS FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT )~ * ':'?-' TOTAL COLOR TRIM {Extensl°nl ~ X 2¢* = g/( ~ ~ ~' /7 Basement SL.S Floors O~c~. Kit. % m~ ~5 ¢~ Ext. Walls ~'//tJ L/C Interior Finish L.R. ~X~enSion Fire Place ~ Heat ~ D.R. ~atio Woodstove BR. i'/ ~rCh ~ X~ ~ /~ .~0 Dormer ~' ~ Z 'leek ~ ~ ;~' Attic ~eezewaY " Rooms 1st Floor ~aragel[ b 7~ .~ Driveway Rooms 2nd Floor ! ~ ~¢: ~ ~ :~ iUILDI~NG I'ERMIT EXAMINER CHECKLIST kpplicaut: _~fi'rrrLo~;_ -[. _/->_o..w__[~ krchitect/Engineer: ~ ~T__~ ICTMS ~000- 7~ ~ /~. ~ Subdivision: 'roperty Address: ~Q _~~ ~ Zone: A ~ Conformiag?F')~ City: ~MJ~x~:~__ Pre COs ? .... luilding permits (Qpen/Expired): B~//0~-z/c/oz~OT&,,fox_q~b BP a~_J~-z/c/0z- ~/¢,fo: ~ llngle & Separate Search Required? Y or'Determination: mQ. LotSize:~OD ~ ACT. LotSize:~ ~ BEQ. LotCov.~O ACT. LotOv. /~ ~Q. Front~ A~h~~I~Q Sid~o/~ ~ Sidem~ REQ. Rear ~ 5 PROP Rear~ / mQ. Height~_ ACT Height~_ '' - ' ~ ~aterfroul ? Y Ol0 -- ~ .... -0 -- lyes, ~a ater body: _ ~ Panel~ Flood Zone: lhdkhead/IHuff D/stance: ¢outhohl '1 ~uslces: 'f c)]9 Date: / / ]outhold 7, BA: 5'<>~(~ Dale: / / Permitff: gouthold Phummg:, ¥ or 9Da~e: ___j.._ /_ _. l'ermit Permit #: - Notes: 'NYS CODE Compl a ]ce (page 2): Y or N Fee Stlnclure: Calcuhdion: t Initial t Additional Fcc ( _ ~: 2. (_ gl) ( $F)= SFX $ + Initial Fee: ~ Additional Fee ( _): NEW YORK ,STATE CODE COMPLIANCE CHECI{LIST CLIMATIC/GEOGkAS'HIC DESIGN CRITERIA: Grountl Snow Load: 45 J Wind Speed: 120MI?H__ eismie Design Category: Weathering: Severe__~/'/~ Frost Depth: Design Temp: 11 Ir/ Ice Shield Underlay: YES ~_ Flood Hazards: USB/OCC~CY CLASS~I~ATION: TYPN OF CONSTRUCTION DESIGN CRITENIA: FULL FRA~{~qG DESIGN ELEMENTS: ItEADEP. S: Y/N XVAJJL STUDY: Y/N CEIk]bING: JOISTS: Y/N FLOOR JOISTS: LUMBER SPECIES AND GI4~XDI?,: Y/N DESIGN LOAD CALCilLATIONS: [}i~:~/N DI~AD: V;N SNOW: Y/N SE[SM[C: Y~ ~IiI~S1 1~; 'll'I};S5 I, iI~IJ1R~;5'IENTS~ LIEU1 VENT 4%% ~N NAIL~G/CONSTRUCTION SCHEDULE: ~/N MEANS OF L(~R],o8 N PLUNdBIN(3 IA1 ~R k)[,~( I,AI4 I I_C)CATIC)N()F FIR1 I'ROTECTIONI~QkJ/J'L1ENT (3 IJFLI) tg [~.S ~ ¥/N [(O O 17 [1 A.FTEIT(S: V£N S U T E R AND S U T E R DESIGN · ARCHITECTURE LANDSCAPE August6,2007 Town of Southold P.O. Box 1179 Southold, NY 11971 Re: Lazio Residence Lake Drive, Southold Draina.qe Notes for stora.qe of 2" rainfall on the property Roof:, Total roof area 5,245 Sq. Ft. x 100% x .1666 x 2 + 42.24 cu ft. (Using 8'-0" drainage units) = 41.38V. F. Use (3) 10' EFF Depth And (1) 12' EFF Depth Total = 42 V.F. Driveway: Total 1,800 Sq. Ft. x .1666 x 2 + 42.24 = 14.2 V.F. Use (2) 8'-0" x 8'-0" EFF Depth Total = 16.0 V.F. Please refer to attached copy of site plan to see locations of storm drains. Thank You! Sincerely, Richard M. Surer P.O. BOX 1709 124 JESSUP AVENUE QUOGUE, NY 11959 631.653.3877 www. suterandsuter.¢om FAX 631.653.3878 REScheck Software Version 4.1.4 Compliance Certificate Project Title: Lazio Report Date: 10/08/08 Data fllename: C:\Users~suter and suter~Desktop~Deil Computer Backups\REScheck\Lazio. mk Energy Code: Location: Construction Type: Heating Type: Glazing Area Percentage: Heating Degree Days: Construction Site: Permit Date: 9-18-06 2007 New York Energy Conservation Construction Code Suffolk County, New York Detached 1 or 2 Family Non-Electric 19% 5750 Owner/Agent: Designer/Contractor: Compliance: 0.4% Better Than Code Maximum UA: 949 YourUA:945 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Wall 2: Wood Frame, 16" o.c. Window 1: Wood Frame:Double Pane with Low-E Door 1: Solid Floor 1: Ali-Wood Joist/Truss:Over Unconditioned Space 2844 30.0 0.0 100 300 22.0 0.0 14 3484 13.0 0.0 286 2000 19.0 0.0 54 1035 0,350 362 63 0.400 25 3144 30.0 0.0 104 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the 2007 N~v Yea~ Energy Conservation Censtruction Code requirements. When a Registered Design Professional has stamped and si~r~ge, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or speci~e. Name - Title Sig~ Date Project Title: Lazio Report date: 10/08/08 Data fllename: C:\Users~suter and suter~Dosktop\Dell Computer Backups\REScheck~Lazio. rck Page I of 4 REScheck Software Version 4.1.4 Inspection Checklist Date: 10/08/08 Ceilings: [] Ceiling 1: Frat Ceiling or Sctssor Tress, R-30.0 cavity insulation Comments: [] Ceiling 2: Cathedral Ceiling (no attic), R-22.0 cavity insulation Comments: Above-Grade Walls: [] Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: [] Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [] Window 1: Wood Frame:Double Pane w~th Low-E, U-factor: 0.350 For windows without labeled U-factom, desoribe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Door 1: Solid, U-facet: 0.400 Comments: Floors: [] Floor I: All-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity insulation Comments: Air Leakage: [] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage am sealed. [] Recessed lights ara 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance Eom combustible materials. If non-lC rated, fixtures ara installed with a 3" clearance from insulation. Vapor Retarder: [] Installed on the warm-in-winter side of all non-vented kamed ceilings, walls, and floors. Materials Identification: [] Matsdals and equipment ara installed in accordance with the manufacturar's installation instructions. Matsdals and equipment ara identified so that compliance can be determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. [] Insulation R-values and g{azing U-factors are cleady marked on the building plans or specifications. [] Insulation is installed according to manufacturar's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the ra~ed R-value without compressing the insulation. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building ara insulated to at least R-8. [] Return ducts in unconditioned attics or outside the building are insulated to at least R-4. [] Supply ducts in unconditioned spaces ara insulated to at least R-8. [] Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on ratum ducts in basements. Duct Construction: Project Title: Lazio Report date: 10/08/08 Data filename: C:\Users\suter and suter~Desktop\Delt Computer Backups\REScheck\Lazio.rck Page 2 of 4 [] All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A cr UL 181B. Exceptions: Continuously welded and Iocidng-type longitudinal joints and seams on ducts operating at iess than 2 in. w.g. (500 Pa). I~ The HVAC system provides a means for balancing air and water systems. Temperature Controls: [] Each dwelling unit has at least one thermostat cspeble of automatically adjusting the space temperature cot point of the largest zone. Electric Systems: [] Separate electric meters exist for each dwefling unit. Fimplaces: ~] Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [] Water heaters with verticsl pipe dsers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is pert of a cimulating system. [] Circulating hot water pipes ara insulated to the levels in Table 1. Circulating Hot Water Systems: [] Circulating hot water pipes are insulated to the tevels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depleteble sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: ~1 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Lazio Report date: 10/08/08 Data filename: C:~Users~suter and suter~Desktop\Deil Computer Backups\REScheck\Lazio.rck Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes insulation Thickness in Inches by Pipe Sizes Non.Circulating Runouts Circulating Mains and Runoute Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (*F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Range(OF) Insulation Thickness in Inches by Pipe Sizes 2' Runouts 1" and Less 1,25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 S~am Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Bdne Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Lazio Report date: 10/08/08 Data filenarne: C:\Ussrs\suter and suter~Desktop~Dell Computer Backups\REScheck~_azJo.rck Page 4 of 4 I (C)OO--T9° ~ o I<~,~ I TOWN OF SOUTHOLD PROPERTY RECORD CARD STREET ..~,~:::~ O VILLAGE DIST. SUB. LOT ~DRMER ~WNER N E ACR. I LAND IMP. TOTAL DATE REMARKS /~ ~ //~,. ~ i ~/;.~/'~ '~J~-L /~'~79~ ~-VJO'i~,s ~ [cx'ss~q-- ~/0~..~ , ~ , ,, ~_ ~ - ~~fc~' . ~'/~,~ F~ONTAGE ON WATE~ TILLABLE F~ONTAGE ON ~OAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT [ ~ q ~, , TOTAL - ~,'~ ~: .: ' ~: -3'/ Idg. EXtenSion ~tio : ~ck Foundation Basement Ext. Walls Fire Place Dormer Dr, iveway SLAB Bath Floors Interior Finish Heat Woodstove Attic Rooms 1st Floor Rooms 2nd Floor COLOR TRIM Dinette Kit. L.R. j BR./ ~ I'/~ z INAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. pREPARED, AND ON HfS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TUTION. GUARANTEES ARE NOT TRANSFERABLE. Note: ALL SUBSURFACE STRUCTURES; WATER SUPPLY, SANITARY DRAINAGE, DRYWELLS AND UTILITIES, SHOWN ARE FROM FIELD OBSERVATIONS ELEVATIONS ~EFE~ TO ASSUMED DATUM THE EXISTENCE OF RIGHTS OF WAY AND OR/EASEMENTS OF RECORD ANY, NOT SHOWN ARE NOT LEACHING POOL DETAIL CYLINDF~ICAL 1500 GALLON SEPTIC TANK WITH DOME NOTES: MINIMUM OF 4" CONCRETE 80~/OM 2. APPROVED REINFORCED PRECAST CONCRETE SOLID R/NO, 8'¢ X 6' HIGH APPROVED REINFORCED PRECAST CONCRETE SOLID DOME OR SLAB MIN. 6" THICK. 12" ~ 24' IdAX. EXISTING $EPTI¢ TANI( AND C~OOL TO ~ R~OV~ AND ABANDONED PROPERLY PROPOSED "NEW" ~ANITARY SYSTEM (2) g'S X g' DEEP LEACHING POOLS t500 GALLON SEPTIC TANK / / / / / TEST HOLE DATA LAND SURVEYING? PHONE: (631) 724 4852 FAX: (551) 724-5455 93 SMITHTOWN BOULEVARD SMiTHTOWN. N.Y. 11787 SURVEY OF LOT 6 MAP OF R£¥DON COURT FILED SEPTEMBER 17, 1987 FgL£ NO 8595 situate at BAYVIEW Town of Southold Suffolk County, N.Y. S.C.T.M. #1000-79-05-16.006 Scale 1"= 40' March 13, 2007 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF Note: ALL SUBSURFACE STRUCTURES; WATER SUPPLY, SANITARY SYSTEMS, DRAINAGE, DRYWELLS AND UTILITIES, SHOWN ARE FROM FIELD OBSERVATIONS AND OR OBTAINED FROM OTHERS ELEVATIONS REFER TO ASSUMED DATUM. THE EXISTENCE OF RIGHTS OF WAY LO1 ? roof d[yweli ~0~6 10' I I I I I I I I I / I AE-A = 40,6 LAND SURVEYING JOHN MINTO, L.S. 95 SM1THTOWN BOULEVARD PHONE: (631) 724 4832 FAX: (631) 724 5455 SM1THTOWN, N.Y. 11787 4o FINAl SURVEY OF lOT 6 WP OF R~DON COURT FILED SEPTEMBER 17, 1987 FlEE NO. 8395 situate at Town of Southold Suffolk County, N.Y. S.C.T.M. #1000-79-05-16.006 Scale 1'= 40' February 9, 2010 GRAPHIC SCALE 0 20 40 80 ( IN FEET ) 1 inch = 40 ft. 160 A8 REQU, -L CODEs OF ~TATE & TOWN, CODEs AND CONDITIONS OF ~ ~ SDUTHOLD TOWN PMNNING BOARD ~ F SO~IqOLD TOWN TRUSTEEB ~,f~-~'--, ~ N/tS. DEC n II OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFI~-AT~ OF OCCUPANCY _j___J F£~/N~ REQUI ~ET,~/N STO~f WATEr~ RU~o- ~ POR~UANT TO OF THE n~,,.. ~HAp~ ~ ~ TO.~ cODE ~--~ APEROV~ AS NOTED DATE:~ PLUMBER CER, TIFICA TION ON LEAD CONTENT BEFORE CERTIFICATE O~ OCCUPAN~Y SOL.DER USEO IN WA TER CERTIFICATION:oF NA LING & CONNECTIONS -'-REQUIRED NOTIFY BUILDING DEPARTMENT AT 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1, FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4, FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ENSIGN OR CONSTRUCTION ERRORS. OF M(NG UN O WITH FOU T/L3 ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODE~ OF NEW YORK STATE, , ~ Z0 "il--- ' 7 S U T E R ~D S U T E' R DESIGN ARCHITECTURE ..' LANDSCAPE P.O. BOX 17.09 124 .[ESSUP AVENUE QUOGUE,' N Y llg_B~ 631.653·3877 www.suterandsu~er.com FAX 631, 653.3878 ttr ¢:~ oo,e. ~ ~.~I S ~3 ~w~X c;onfo l,'I:,or~ 5 ?'To 7 I U T E R' MD '- S U T E R :SIGN ARCHITECTURE LANDSC, APE · BOX 1709 124 jESSUP AVENUE 'OUOGUE. NY 11950 1. 653·3877 www.suterandsuf~er.com FAX 631. 6'SS.3878 Z. ¢/.0 ,"z: ,l_lO [0 ye ,,2 END 2 L]C. 12" O,C MTS16 LTP4 Figure 3.8b Corner Stud Holddown Detail - 4 Studs // "1 S U' T E R MD S U T E R DESIGN ARCHITECTURE LANDSCAPE P.O. BOX 1709 /' 124 IESSU'P AVENUE OUOGUE. NY 11959 www.suterandsuter.com F AX 631. 653.3878 631.653'.3877 II II - .-, ;-t_¢._4' : 4? 4%" D S' U T E R ~D S U T E R 124 .IESSUP AVENUE OU'OGUE. N Y 11950 www.suterandsuter.com F A X 6 3 1, 6 5 3.3 8 7 8 P.O. BOX 1709 631. 653.3.877 "_., II :S -% If I ,2u --I U T E R A~ S 0 'T~ E R DESIGN ARCHITECTURE LANDSCAPE P.O. BOX 1709 531, 653.3877 124 IESSUP AVENUE www.suterandsutez.eom OUOGUE. N Y 11959 FAX 631- 653-3878~ fid -: ' d U T E R ~ S U 'T' E R I G N A R C H I'T E CT UR E L AN D S C AP E BOX 1709 124 JESSUP AVENUE ' OUOGUE. NY 11959 653,~877 w~rw.suterandsuter.com FAX 631, 653·3878 WIND-BORNE DEBRIS PROTECTION FASTENING FOR WOOD STRUCTURAL PANELS. For Max. 33'-0" MEAN ROOF HGT. HOUSES AZ.A. SPAN RATED 48~24 GRADE 15/32 STRUCTURAL SHEATHING -OVERLAP OPENING MIN. 4' TO ALLOW FOR FASTENER CONNECTION AND 2X4 SUBSTRATE WHERE REQ'D. ALL METAL PARTS TO BE GALV. OR STAINLESS STEEL. ALL PANELS, SUBSTRUCTURES, AND FASTENERS TO BE STORED AT HOUSE. ..... Z.¢_4 CuD~,:~cT~' ~ ,? I%- &r PAi~ S T E -R AND 'U DES N A,RC H I T E C T U R ~L AN~D-S C AP P.O. BOX 1709 124 IESSUP AVENUE OUOGUE, N Y 11959 631. 653.3877 www.suterandsuter.com FAX,631. 6'53.3878 - 0o8'0 S U T E R MD S U T E .R DESIGN ARCHITECTURE LANDSCAPE BOX 1709 124 /IESSUP AVENUE QUOGUE. NY 11959 I '6 5 3 · 3 8 7 7 www.suterandsuter.com F AX 6 3 1, 6 5 3.3 8 7 8 CONSTRUCTION NOTES 1) ALL FOOTINGS TO REST ON VIRGIN BOIL & BE A MIN. 3'-O" BELOW FINISHED GRADE. 2) ALL CONSTRUCTION TO CONFORM TO ALL STATE & TOWN BUILDING CODES INCLUDING 2003 CHANGES, 3) ALL CONCRETE TO BE MIN. 3,000 P,B.I. 28 DAY STRENGTH. 4) ALL FRAMING LUMBER TO BE OOUG. FIR #2 UNLESS NOTED OTHERWISE. 5) BRIDGING MP3(. fi-O" ON CENTER. B) DOUBLE FLOOR JOISTS UNDER PARALLEL PARTITIONS AND BATHROOMS· 7) DOUBLE JACK STUDS UNDER HEADER OF ALL SPANS OVER 4'-g". MIN. HDR SIZE (2) 2X10 UNLESS NOTED. 8) ALL FRAMING NAILS TO BE GALVANIZED NEAR SALT WATER EXPOSURE. E) RELATIONSHIPS OVERRIDE DIMENSIONS, DIMENSIONS OVERRIDE SCALING· .10) ALL BUILD UP GIRDERS TO BE GLUED & NAILED. ALL LUMBER TO BE CONTINUOUS LENGTHS. 11) ALL BUILT UP FLITCH BEAMS TO HAVE V~" DIA. BOLTS 16" ON CENTER ON BO'FrOM & 24" ON CENTER ON TOP, ALL TO BE 2" FROM EDGE· M~N. 3"XB"X114" STEEL BEARING pLATE AT EACH END. 12) UTILITY AREA OF FURNACE AND ATTACHED GARAGES TO BE FINISHED WITH E/S" FIRE PROOF G.W B. TO CODE· 13) FIREPLACE TO BE SUPPLIED WITH FRESH AIR VENT AND GLASS DOORS PER 2go3 ENERGY CONSERVATION CODES AND FiRE PROOF HEARTH TO BE INSTALLED PER CODE· (FRAME FLOOR JOISTS PER CODE AT HEARTH WITH REQUIRED SETBACK). FIREPLACE FOOTING TO BE 12" THICK AND EXTEND S" BEYOND FIREPLACE POUR· WELDED WIRE MESH 2" FROM BOlq'OM TO BE IN THE FOOTING· 14) DENOTES 4X4 C.C.A. POST ON 4"XS"X16" CONCRETE BLOCK 3'-0" BELOW GRADE· ALL DECK FRAMING TO BE .4 C.C,A. PRESSURE TREATED LUMBER· 15) DENOTES 3 %" DIA. LALLY COLUMN ON 24"X24"X12" THICK POURED CONCRETE FOOTING· LALLY COLUMN TO BE FILLED WITH POURED CONCRETE. 16) DENOTES 8"X16" CONCRETE PIERS ON 16"X24"X12" POURED CONCRETE FOOTING· 17) BASEMENT SLAB TO BE 4" POURED CONCRETE· 18) CRAWL SPACE SLAB TO BE 2" POURED CONCRETE. 19} GARAGE SLAB TO BE 4" POURED CONCRETE WITH 6"XB"XB/B STEEL MESH REINFORCING ON COMPACTED SAND & GRAVEL. PITCH SLAB TO DOOR MIN. %" PER 1'0". 20) FURNACE AREA TO HAME FRESH AIR VENT AND FIRE PROOF FLOOR TO CODE· 21) INSTALL FIRE STOP BLOCKING IN ALL LOAD BEARING WALLS· 22) FIRESTOP PREFAB. FLUE SHAFT TO CODE· MAX. 8'-E' ON CENTER WITH 1 HOUR RATING USE TYPE 'X' GYPSUM BOARD; 23) SEPARATE HOUSE AND ATTACHED GARAGE TO CODE 45 MIN. RATED WALL, DOOR, & JAMB. DOOR TO BE SELF CLOSING, 24) IF A SWIMMING POOL IS iNCLUDED IN THE PROJECT, IT MUST BE ENCLOSED WITH A 4' HIGH FENCE & SELF-LATCHiNG GATES, TO NYS CODE, 25) NOTE: ALL LUMBER TO BE INSTALLED AFTER MOISTURE CONTENT REACHES AMBIENT EQUILIBRIUM CONDITIONS El, GIRDERS, FL. JOIST, TRIM, ETC. 26) INSTALL G,',LV, RAFTER TIE DOWNS TO TOPPLATES IN ALL FULL HGT, CLGS. (CATHEDRAL) & ALL RAFTERS AT SEASHORE. (SEE HIGH WIND NOTES) 27) BUILDING FELT (OR TYVEK OR EQ.) TO COMPLETELY COVER SHEATHING. 28) IF WOOD T BEAMS, MICROLAMB OR EQUAL ARE USED, FOLLOW ALL MANUF SPECS, FOR SITE STORAGE, INSTALLATION, DRILLING, BLOCKING, & LOADING, 29) THE ARCHITECT iS NOT RESPONSIBLE FOR CONSTRUCTION MEANS OR METHODS, ' 30) ANY STRUCTURAL CHANGES IN THE PLANS MUST BE APPROVED BY THE ARCHITECT OR THE ARCHITECT IS NOT RESPONSIBLE FOR THE ENTIRE PROJECT, 31) THE ARCHITECT ASSUMES NO SITE CONDITIONS THAT ARE NOT INCLUDED IN THE FLANS. ANY ROCK FORMATIONS, BEDROCK, UNDERGROUND STREAMS, FTC, MUST BE SITE INSPECTED BY A LOCAL ENGINEER & ANY STRUCTURAL CHANGES THAT OCCUR THAT CHANGE THE PLANS ARE NOT THE RESPONSIBiLiTY OF THE ARCHITECT, 32) COPYRIGHTED: ARCHITECTURAL WORKS COPYRIGHTPRGTECTIONACTPER UNITED STATES CODE ALL ARCHITECTURAL WORK CREATED AFTER DECEMBER 1, 1990, INCLUDING THIS SET OF PLANS, IN TERMS OF OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPECS AND ELEMENTS IN THE DESIGN, FOR A PERIOD OF 75 YEARS. COMPLIANCE WITH RESIDENTIAL CODE OF NEW YORK STATE DATED JAN. 1~ 2007 Ground Wind Seismic weathering Frost Termites Decay Winter [ce shield Flood snow speed Design line Design underlay- Hazards lead (Mph) Category dept Tamp ment· ~f~ Moderate ' required PSF zo % sevare IB.`gM. 111FI¥ -heaWmoderate ~ ~ Air Freemng Index TYPICAL WALL SECTION VENT TOP OF ROOF W/RiDGE VENT OR ROOF VENTS TO CODE BATT INSULATION W/VADOB BARRIER ON HEFTED SIDE, I % GYP. SD. SIDING TYVEK-INSTALL BEFORE WINDOWS %' OSB OR CDX I 2x6 AT 18" ON CENTER Wig ~A' gATT INSULATION'OR -- gx4 AT 16" ON CENTER WI3 %" BATT INSULATION %'GYP. ED, FINISHED FLOOR ~" CDX SUBFLOOR GLUED AND SCREWED TO JOIST AIRSPACE BATT INSULATION W/VAPOR BARRIER TO HEATED SIDE. 2" P.C. SLAB AT CRAWL SPACE §" P.C, FOUNDATtON WALL WIDAMPROOFING ON EXTERIOR CLEAN SAND BACNF[LL · 16" X 8" P,C. FOOTING W/NEY ON VIRGIN SOIL & MIN 3'0" BELOW GRADE COMPLIES WITH TABLE R403.1 S FIG. R403,1 (I) CONFIRM DRAINAGE ~f BOIL. IF INADEQUATE, INSTALL CONTINUOUS FOOTING DRAIN TILE TO STORM DRAIN, Table 3.1 CONCRETE COMPRESSIVE STRENGTH [ SEVERE ] BASEMENT WALLS & SLABS - 3,000 PSI GARAGE SLAB 3,500 PSI Nailing Schedule Table 3.2A! Sill or Bottom Plate to Foundation Anchor Bolt Connections Resisting Lateral & Shear Loads (Prescriptive Alternative to Table 3.2) i ,INEW YORK STATE RESIDENTIAL CODE: (mph) (mph) Anchor Bog Foundation Bracing Wall Promoter Maximum Anchor Bolt :, M~ximum Anchor Bolt Connection Supporting Edge Nall Spacing (in) Spacing (in.) Spacing (in.) Table 3.21t Sill or Bottom Plate to Foundation Anchor Bolt Connections Resisting Uplift (Prescriptive Alternative to Table 3.2) (mph) (mph) ' ~OMPLI/~NCE W/gb -E66E-, " ..... B'ir~O~~l.~WOOD FRAME' CONSTRUCTION MANUAL 1995 EDITION USING PRESCRtP'[FIVE DESIGN METHOD. %"' DIAMETER "J" BOLT PER TABLE 3.2A & 3.2B CENTE~ ,,SPACING INTO FOUNDATION WITH 4" x 4" x N" B.P. PLATE OVER SILL PLATE. USE 1 ¼ X 20 GAGE STRAPS @ EACH JOINT., SILL PLATE TO FIRST FLOOR WALL STUDS, lS~ FLOOR WALL STUDS TO 2D~oR WALL STUDS, WALL STUDS AND TOP PLATE TO IROOF RAFTERS A~,D, OVER RIDGE AT EACH RAFTER OR 2X4 COLLAR TIE IN UPPER THIRD OF ATTIC AT 16 ON CENTER. ASPHALT SHINGI~ES FOLLOW NAILING SCHEDULE R905.2.6 MIN 6 FASTENERS PER SHINGLE, BLDG. FELT, INSTALL PER R905.2.7 ND ........ 4.~ne; n,,n~rm ~v-~ne m3 B'653-3877 ~ (ICE SHIELD REQUIRED FOR 1sT 24" ABOVE START Of INTERIOR WALL) N.Y.S. BLDG 'SUTER A . SUTER · PO' BOX ,,,~o '.... ,.....-.-, ..... ,~-..-, ~g.- t .' ....._!CO._.DE-..~T~R~LE_R_.3.DI.~2_2~N_D_Q..W_~S TO MEET D.P. RATING OF MIN. 40 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) USE LIVE LOAD (LBP Typical BP Installed Anchor Bog Table S,2 Sill or 11ottom Plate to Foundation Connection Requirements 20 24 32 36 32 36 20 24 · 28 36 24 32 36 32 E971 Table 3.4 Ridge Tension Strap Connection Requirements ® r~ · '; Table 3.3E 'i Uplift Strap Connectior Requ rements (Roof-to-Wall, Wall-to-Wall, and Wall-to-Foundation) (Prescriptive Alternative to Table 3,3) t.3A CHAPTER 600 HOUSE RATIO LESS THAN 4:1 STRUCTURAL SHEATHING TO BE FULL HGT. SECURE TO TOPPLATE. ROOF PITCH ~ 55.0 ~- MAX 42% GLASS OK I I Table 3.7 3:12 Rafter/Ceiling Joist Heel Joint Connection Requirements for 20 psf Roof Live Load Rafter/Ceiling Joist to Top Plate Lateral- and Shear Connection Requirements (Prescriptive Alternative to Table 3.3) i 24 3 ~ 3 3 3 3 3 3 3 3 ', 3 3 4 3 d ' 5 5