Loading...
HomeMy WebLinkAbout35323-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34497 Date: 08/09/03 THIS c~RTIFIES ~hat the building NEW DWELLING Location of Property: 8755 NEW SUFFOLK RD NEW SUFFOLK (HOUSE NO.) (STREET) (HAMLET) County Tax Map NO. 473889 Section 117 Block 10 Lot 14.1 Subdivision FiledMap No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 29, 2010 purs,,~-t to which Building Permit No. 35323-Z dated JANUARY 29, 2010 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH COVERED FRONT PORCH, REAR DECK, BALCONY AND NON-HABITABLE THIRD FLOOR PER ZBA #5382, DATED 8/7/03. The certificate is issued to WILLIAM C & DONNA GOGGINS (OWNER) of the aforesaid building. SUF~OLKCOUNTYDEPART/~ITOFHI~ALTHAPPROVAL N/A m.Rt-rKICAL c~TIFICATE NO. 133011C 04/01/10 PLIghtERS C~K'rIFICATION DA'£~U~ 09/16/09 WILLIAN GRE~U~ER Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35323 Z Date JANUARY 29, 2010 Permission is hereby granted to: WILLIAM C GOGGINS MATTITUCK, NY 11952 for : DEMOLISH AND RECONSTRUCT DWELLING. THIS PERMIT REPLACES BP 29726. at premises located at 8755 County Tax Map No. 473889 Section 117 pursuant to application dated JANUARY NEW SUFFOLK RD NEW SUFFOLK Block 0010 Lot No. 014.001 29, 2010 and approved by the Building Inspector to expire on JULY 2__9: 201~1. Fees 3,014.20 ~~~ ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES COMPLETION OF THE WORK AUTHORIZED) UNTIL FULL PERMIT NO. 29726 Z Date SEPTEMBER 11, 2003 Permission is hereby granted to: WILLIAM C GOGGINS MATTITUCK,NY 11952 for : CONSTRUCTION OF A COVERED PORCH ADDITION AND ROOF REPAIR AS APPLIED FOR PER ZBA at premises located at 8755 County Tax Map No. 473889 Section 117 pursuant to application dated SEPTEMBER NEW SUFFOLK RD NEW SUFFOLK Block 0010 Lot No. 014.001 4, 2003 and approved by the Building Inspector to expire on MARCH 11, 2005. Fee $ 150.00 Auth~rized~ignature ORIGINAL Rev. 5/8/02 Form No. 6 TOWN OF SOUTIIOLD BUILDING DEPARTMENT TO~N HALL 765-[802 APPLICATION FOR CERTIEICATE OF OCCUPAN This application must be filled in by typewriter OR ink inspector with the following: for new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial bnilding, industrial building, multiple residences and similar buildings and' installations, a certificate.of Code Compliance from architect or engineer. responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildiogs and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Iaspector shall state the reasons therefor in writing to the applicant. 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory buildieg $25.00. Bnsinesses $50.00. 2. Certificate of Occupancy on Pre-existin~ Buildin~ - $100.00 3. Copy of Certificate of Occupancy - $20.00 4. Updated Certificate of Occupancy - $50.OO 5. Temporary Certificate of Occupancy - Residential $15.00-, Commercial $15.00 Date ..Ma=~t~8~l.ZOLO ......................... New Coastruction ........... Old Ut Pre-existing Building .... ~. ........... Location of Property./~.!!~q .J~P~.-~EF~.'. ~.~9~.~9¥.¥9~ ............................ House No. Street llamlet Onwer or Owners of Property.~l~.~ F.'. Pg~. ~.PP~f.~:.Pgggg9P .......................... ':ounty Tax Hap No 1000, Sectio,~..1.1.7...0.0 ....... I]l,,ck...~9.-99 ......... ............. N/A N/.A ..... N./.A.. 3ubd£vision .................................... Fi lcd Hap ....... Lot ................. · 35323 .............. ~'erl, it ~o ................ Date Of Permit 01/30/2010 ..Applicant...S.a.m.e.~$.~%TO~ .............. N/A Health Dept. Approv,~l .......................... Underwriters Approval ..................... 'lanuing Board Approval N/A " Request for: Temporary Certificate ........... Final Cgrticate ........... Tee Submitted: $ 25,00 .... :x' ......... . . . . ....... .t . . . ........... Issue Date 4/1/2010 Electrical Inspection Certificate Electrical Inspection Service, Inc. Application Number 375 Dunton Avenue 13301 lC East Patchogue, New York 11772 (631) 286-6642 Issued To: Street: Village: Section: William C. Goggins 1780 Jackson Avenue New Suffolk Zip: 11956 117.00 Block: 10.00 Lot: 014.001 Contractor: Frank Mineo Electric (L) Town: Southold Lic.# 2729-E Was examined and found to be in compliance with the National Electrical Code. ~ Commercial L~ NVDefects ~i Pool ~Xl lstFIoor IX Indoor [] Basement [] HotTub X~ Residential ~ Det. Garage x Attic A~ 2nd F JOt [~ Outdoor L~ Addition [] Survey Switches Receptacles Fixtures GFI Heaters 100 135 151 25 Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps 3 2 20 2 30 1 gas Furnace Oil Gas Circulators Smoke Detector 1 x 5 11 Meter Amps Phase UG/OH Jacuzzi Television 1 400 1 / 1 A/C Fans 4 Microwaves 1 Bell Transformer CO Detector 5 Bldg. Permit: Other Equipment 2-200amp main breaker/125 sub panel/ 60amp sub panel / 1-20amp special panels / il00amp sub panel / 1-20amp ac / 3 - 30amp Cc / 4-20amp ah disconnects / 50amp hot tub isconnect Hugo S. Surdi President Rough Inspection: ins or Inspector: ~ John Mc Mahon III This certificate must not be altered in any manner. Inspectors may be identified by their credentials. Town H-q, ~3095 ~,~ Roa~ P. O. Box 1179 Soc~ok~, ~r~York 11971 F;u((5t8) 7~5-1~23 Telephone (51e) 785-1802 OFFICE OF THE BUILDING INSPECTOR TOWN OF 80UTHOLD CERTIFzc&?ZON Building Perm£t ~o. _~ O~ner: _ ~/~ ~~ (please prifl~) Plumber: _ ~/~, (please print) I certify that the SOlder used in the water supply system contains less than 2/10 of ~% lead. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]ROUGH PLBG. [ ]FOUNDATION 2ND [ ]INSULATION [ ] FRAMING / STRAPPING ~;,~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ~~--~'~~~" ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ] ROUGH PLBG. [ ]FOUNDATION 2ND [ ] INSULATION [ ]FRAMING / STRAPPING ~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] RRE RESISTANT PENETRATION R.'ARKS.' .,b~~ ~'~,. ~~ $~/~-~/ ~ INSPECTOR~~ ~ DATE ~ ,~ . TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [_ ] FIRE RESISTANT PENETRATION REMARKS: Co~ O, Z ;~'~- ~ ~ JAMESJ. DEERKOSKI, P.E. 260Deer Drive Ma~tituc~ N.Y. 11952 (631) 298-7116 To: Town of Southold Re: S epticJBasement Certification Bill Goggins Fifth Street Cutchogue, NY 11935 To whom it May Concern: This letter certifies thax the existing geptic System is Sufficient in size to handle the laods placed upon it by the new addition. Also, the basement of this residence is more than 50% below grade arotmd its perimeter. Any questions please feel free to call. JAMES J. DEERKOSKI, P.E. 260 Deer Drive Matfituck, N.Y. 11952 (631) 298-7116 Date: May 15, 2006 To: Town of Southold Building Dept Re: Habitable Space Goggins 1780 Jackson St. New Suffolk, NY To Whom It May Concern: After an site inspection, a average ceiling height calculation was performed on the space above the second floor, it is deemed habitable because not more tban 50% of this space between the top of floor beams and the ceiling level is less than 7'-6' in height. Tiffs Structure is also equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13D. Any questions please feel free to call. ''S~ncercl P.E. JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 Date: To: Re: May3,2006 Town of Southold Building Dept. Framing/Plumbing/Strapping/Insulation Inspection Goggins 1780 Jackson St New Suffolk, NY To Whom It May Concern: After a Framing, Strapping and Insulation inspection was performed on the above property, it is deemed that all work performed was completed to plans and meets all state and local codes. A Plumbing Inspection was also performed on this structure with a pressure test on the copper and the vent stack being filled with water to the roof. Any other questions please call. S ncerely Jarl es J. 15eerkoski Date: To: Re: JAMES J. DEERKOSKI P.E. 260Deer Drive Mattimck, NY 11952 (631) 774 7355 June 11, 2010 Town of Southold Building Dept Egress Compliance Goggins 1780 Jackson St. New Suffolk, NY To Whom It May Concern: This is to certify that the window in the NE Bedroom on the second floor is Egress Compliant with all State and local codes. If you have any questions, please do not hesitate to contact me. Thank You. BLDG, OEPI. JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 Date: June 15, 2010 To. Town of Southold Building Dept Re~ Goggins 1780 Jackson St. New Suffolk, NY SCTM No. 1000-0117.00-10.00-014.001 To Whom It May Concern: Upon a site inspection made this date of the space above the second floor, although the space is insulated, sheetrocked, heated, and contains a wet automatic sprinkler system in accordance with NFPA 13D and meets with the criteria for habitable space in accordance with the New York State Uniform Fire Prevention and Building Code it is deemed uninhabitable because it is unfinished and the access to the space is through a second floor ceiling opening. Any questions please feel free to call. koski P.E. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined ,20 Approved ,20 Disapproved a/c Expiration ,20__ PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 3 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: Phone: Building Inspector APPLICATION FOR BUILDING PERMIT Date June 6, 2003 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by, this application may not be commenced before issuance of Building Permit. · y d. Upon approval ofthis~application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shallbe kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within ! 8 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 0wIler Name of owner of premises William C. Goggins and Donna M. Goggins (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders LicenseNo. Plumbers LicenseNo. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 1780 Jackson Street, New Suffolk House Number Street County Tax Map No. 1000 Section Subdivision (Name) 117 Hamlet Block 10 Filed Map No. Lot Lot 14.1 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Roof over existing dwelling b. Intended use andoccupancy Roof over existing dwelling with reverse gables Nature of work (check which applicable): New Building Repair Removal Demolition Estimated Cost $10_.non_ on Fee If dwelling, number of dwelling units If garage, number of cars Addition Alteration Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front Height Number of Stories Rear Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories _Depth Dimensions of entire new construction: Front Height Number of Stories Rear 9. Sizeoflot: Front 100 10. Date of Purchase 10-20-01 11. Rear _Depth Rear 75 Depth 351 Name of Former Owner Rlchard Goodale Zone or use district in which premises are situated R-40 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO x 13. Will lot be re-graded? YES __ NO__Will excess fill be removed from premises? YES__ NO__ 14. Names of Owner of premises NameofArchitect Donald Fieler Name of Contractor Address Address Address Phone No. Phone No ~08-s4sa Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES __NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES x NO__ * IF YES, D.E.C. PERIVlITS M.AY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) William C. Goggins being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the Owner (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swom to before me this 6th day of ~lune Notary Public 20 03 Signat~'e oiV'A ~;NE T. VILLANO TOWN OF SOUTHOLD BUILDING DEPARTMEN~F TOWN HALL ~ SOUTHOLD, NY ;11971 TEL: (631) 765-18~2___ y FAX: (631) 765-9502 www. northfork.net/Southold/ Examined Approved Disapproved BUILDiNG PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health ~ 3 sets of Building Plans t~. .... I Planning Board approval Survey_ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees ~ C°ntact:Mail t°: APPLICATION FOR BUILDING PE~IT Expiration Date May 30, ,20 03 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months al]er the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the constmction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder OWNER Nameofowner of premises William C. Goggins and Donna M. Goggins (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 1780 Jackson Street, New Suffolk House Number Street County Tax Map No. 1000 Section Subdivision N/A (Name) Hamlet Block I o Filed Map No. Lot Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Porch over existing concrete slab b. Intended use and occupancy Porch over deck 3. Nature of work (check which applicable): New Building_ Addition x Alteration x Repair Removal Demolition Other Work Estimated Cost $ 2,000.00 If dwelling, number of dwelling units If garage, number of cars Fee (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 8. Dimensions of entire new construction: Front Height Number of Stories Dimensions of existing structures, if any: Front Rear ~' Depth Heigh[ Number of Stories See. plans attached hereto ~ Dimensions of same structure witn alterations or additions: Front Rear Depth Height_ Number of Stories See, plans attache~ hereto Rear Depth 9. Size of lot: Front 100 Rear 75 .Depth 351 10-20-01 10. Date of Purchase Name of Former Owner Richard Goodale 11. Zone or use district in which premises are situated R-40 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO x 13. Will lot be re-graded? YES NO x Will excess fill be removed from premises? YES NO x 14. Names of Owner of premises Name of Architect Donald Fieler Name of Contractor Address Address Address PhoneNo. Main Road, Mattit~eNo Phone No. 298-5453 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES x NO__ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. N0 NO 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF Suffolk) William C. Goggins being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the owner (Contractor, Agent, Corporate Officer, etc.) of~Itd~a:ai~g~ and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworato before me this (.~,t~ ~ day of Notary Public 20 D ~-~ New York State Department of Environmental Conservation Division of Environmental Permits, Region One Building 40 - SUNY, Stony Brook, New York 11790-2356 Phone: (631) 444-0365 · FAX' (631) 444-0360 .... ~ Website: www.dec.state.ny.us ~ ~ ~ ~,/~ ~' ~ LETTER OF NON JURISDICTION - ARTICLE 25 Denise M. Sheehan Acting Commissioner William Coggins PO Box 65 Mattituck, NY 11952 March 25, 2005 Re: Application #1-4738-03411/0000l Coggins Property, 1780 Jackson Street,Ne;v Suffolk, SCTM #1000-117-10-14.001 Dear Mr. Coggins: Based on the information you have submitted the Department of Environmental Conservation (DEC) has determined that the property landward of the bulkhead, as shown on an aerial photograph dated 4/6/76, which existed prior to August 20, 1977, is more than 100' feet in length and remains functional, is beyond Article 25 (Tidal Wetlands Act) jurisdiction. Therefore, in accordance with the current Tidal Wetlands Regulations (6NYCRR Part 661) no permit is required. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, /~rarkark~Carrara Deputy Permit Administrator cc: MHP file FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: May 3, 2003 TO: William Goggins 8755 New Suffolk Road New Suffolk, NY 11956 Please take notice that your application dated May 3, 2003 For permit for construction of a porch addition at Location of property: 8755 New Suffolk Road, New Suffolk, NY County Tax Map No. 1000 - Section 117 Block 1~0 Lot 14.1 Is returned herewith and disapproved on the following grounds: The proposed construction, on this conformin~ 41,205 square foot lot in the Residential R-40 District, is not permitted pursuant to Article mA, 100-30A.3, which states, "No building or premises ahall be used and no building or part thereof shall be erected or altered in the Low-Density Residential R-40 District unless the same conforms to the requirements of the Bulk Schedule and of the Parking Schedule, with the same force and effect as if such regulations were set forth herein in full." Bulk schedule requires single side yard setback of 15 feet and a total side yard setback of 35. The proposed construction will have a single side yard setback of 9 feet and a total side yard setback of 24 feet. Total lot coverage, following the proposed construction, will be less than 20 percent. Note to Applicant: Any change or deviati.o.n.to th~ication, may require further review by the Southold Town Building Department. V 8CC: ZBA, File TO: William Goggins 8755 New Suffolk Road New Suffolk, NY 11956 FORM NO. 3 TOWN OF SOUTHOLD BUILDiNG DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: May 3, 2003 AMENDED: May 16, 2003 Please take notice that your application dated May 3, 2003 For permit for construction of a porch addition and second story addition (roof repair) at Location of property: 8755 New Suffolk Road, New Suffolk, NY CountyTax Map No. 1000 - Section 117 Block 1~0 Lot 14.1 Is returned herewith and disapproved on the following grounds: The proposed construction, on this conforming 41,205 square foot lot in the Residential R-40 District, is not permitted pursuant to Article IliA, 100-30A.3, which states, "No building or premises shall be used and no building or part thereof shall be erected or altered in the Low-Density Residential R-40 District unless the same conforms to the requirements of the Bulk Schedule and of the Parking Schedule, with the same force and effect as if such regulations were set forth herein in full." Bulk schedule requires single side yard setback of 15 feet and a total side yard setback of 35. The proposed construction will have a single side yard setback of 9 feet and a total side yard setback of 24 feet. In addition, the second story repairs, along with the addition of reversed gables, will maintain the existing single side yard setback of 5.9 feet and total side yard setback of 15.9 feet. Total lot coverage, following the proposed construction, will be less than 20 percent. This permit was amended on May 16~ 2003~ to include additional work proposed by the applicant. Authorized Signature Note'to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. 8CC: ZBA, File FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: May 3, 2003 AMENDED: May 16, 2003 AMENDED: September 3, 2003 TO: William Goggins 8755 New Suffolk Road New Suffolk, NY 11956 Please take notice that your application dated Ma,/3, 2003 For permit for construction of a porch addition and second story addition (roof repair) at Location of property: 8755 New Suffolk Road, New Suffolk, NY County Tax Map No. 1000 - Section 117 Block 10 Lot 14.1 Is returned herewith and disapproved on the following grounds: The proposed construction, on this conforming 41,205 square foot lot in the Residential R-40 District, is not permitted pursuant to Article IliA, I00-30A.3, which states, "No building or premises shall be used and no building or part thereof shall be erected or altered in the Low-Density Residential R-40 District unless the same conforms to the requirements of the Bulk Schedule and of the Parking Schedule, with the same force and effect as if such regulations were set forth herein in full." Bulk schedule requires a front yard setback of 50 feet. The existing single family dwelling has a front yard setback of 5.9 feet. The proposed addition will have a front yard setback of 9. In addition, the second story repairs, along with the addition of reversed gables, will maintain the existing front yard setback of 5.9 feet. Total lot coverage, following the proposed construction, will be less than 20 percent. This permit was amended on May 16~ 2003~ to include additional work proposed by the applicant. This permit was amended on September 3~ 2003~ to correct errors. Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. 8CC: ZBA, File FORM NO. 3 NOTICE OF DISAPPROVAL DATE: August 30, 2004 TO: William Goggins 8755 New Suffolk Road New Suffolk, NY 11956 Please take notice that your application August 26, 2004 For permit for "as built" additions and alterations to an existing single family dwelling at Location of property: 8755 New Suffolk Road, New Suffolk County Tax Map No. 1000 - Section 117 Block 10 Lot 14.1 Is returned herewith and disapproved on the following grounds: The "as built" construction, on this 42,688 square foot parcel, with two front yards, located in the R-40 zone, is not permitted pursuant to Article XXIV Section 100-242A, which states; "Nothing in this article shall be deemed to prevent the remodeling, reconstruction or enlargement of a non-conforming building containing a conforming use, provided that such action does not create any new non-conformance or increase the degree of non-conformance with regard to the regulations pertaining to such buildings." The existing single family dwelling notes a 5.9 foot front yard setback (Fifth Street). Following the proposed construction, the dwelling will maintain that setback. Pursuant to the ZBA's interpretation in Walz (#5309), such construction will thus constitute an increase in the degree of non-conformance. Therefore, the "as built" construction is not permitted pursuant to Article IliA, 100-30A.3, which statesl "No building or premises shall be used and no building or part thereof shall be erected or altered in the Low-Density Residential R-40 District unless the same conforms to the requirements of the Bulk Schedule and of the Parking Schedule, with the same force and effect as if such regulations were set forth herein in full." Bulk schedule requires a front yard setback of 50 feet. In addition, the "as built" addition constitutes a third story, which is not permitted pursuant to Article II[~ct-OQ-30 A.3. Bulk Schedule states that such buildings are limited to 2 ½ stories. a/i~,~-EX'~an~iner Note to Applicant: Any change or deviation to the above referenced application, may require FORM NO. 3 NOTICE OF DISAPPROVAL DATE: August 24, 2006 TO: William Goggins 8755 New Suffolk Road New Suffolk, NY 11956 Please take notice that your application August 26, 2004 For renewal of and amendments to expired building permit #29726Z for additions and alterations to an existing single family dwelling at Location of property: 8755 New Suffolk Road, New Suffolk County Tax Map No. 1000 - Section 117 Block 10 Lot 14.1 Is returned herewith and disapproved on the following grounds: The "as built" amended drawings, submitted to this office, do not meet the conditions of Zoning Board of Appeals variance #5061, which states, in part, "The third-story shall not be habitable in space..." Although the "as built" third story conversion meets New York Stet code requirements, it violates the conditi~ of v_our Z~ and the amendment cannot be processed. D~s, Permit Examiner Note to Applicant: Any change ~ve referenced application, may require further review by the Southold Town Building Department. CC: file, Z.B.A. further review by the Southold Town Building Department. CC: file, Z.B.A. API~TALS~BOARD MEMBERS Lydia A. Tortora, Chair~voman Gerard P. Goehringer George Horning Ruth D. Oliva Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 ZBA Fax (631) 765-9064 VincenI..Orlando Telephone (631) 765-1809 ~ ~ ~ http://southoldtown.northfork.net 5r-D /[ :,,t ~ TOWN OF SOUTHOLD I F~NDINGS, DELIBE~TIONS AND DETERMINATION BLD~, D~ j MEETING OF AUGUST 7, 2003 Appl. No. 5382 - William and Donna Goq~ins Prepe~y Location: ~7~0 ~ackson Street and 8755 New Suffolk Road, New Suffolk; Parcel ~7M0-~4.~ (~3 and ~4 combined as one lot). SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 41,206 sq. ft. parcel is improved with a two-story wood frame dwelling, garage (under construction) and swimming pool (under construction), as shown on the survey prepared by Stanley J. Isaksen, Jr. dated October 21, 2002. The property consists of two formerly identified County Tax Map Nos. 13 and 14, which are now combined to form a single lot, identified on the County Tax Maps as Lot 14.1. For the record it is noted that the former Accessory Bed and Breakfast was removed and is no longer in effect for the existing single-family dwelling. BASIS OF APPLICATION: Building Department's May 3, 2003 Notice of Disapproval, amended May 16, 2003, citing Section 100-30A.3 in its denial of a building permit to construct an addition and roof repairs to the existing dwelling with a single side yard at less than 15 feet and less than 35 feet for a combined side yard total. The applicant voluntarily merged former County Parcel Nos. 13 and 13 and removed the Accessory Bed and Breakfast Use. Formerly the northerly setback was a side yard, before the parcels merged. Currently, both yards meet the definitions of the Zoning Code as front yards as fronting along mapped streets (Jackson Street to the north and Fifth Street to the west). FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on July 24, 2003, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the properly, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: Applicant wishes to redesign and reconstruct the existing open porch facing Jackson Street, with alterations to the existing dwelling, as shown on the plot plan and construction diagram prepared by Donald G. Feller, I~age 2 - August 7, 2003 Appl. No. 5382 - W. and D. Goggins 117.-10-14.1 at New Suffolk Architect dated 5/6/2003. The setbacks of the dwelling are 5.9 feet and 9 ft. from the west property line along Fifth Street, at its closest points. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the relief requested will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Applicants propose the reconstruction and rehabilitation of existing porch areas, along with reverse gable roof, as shown on the plan dated/5/6/2003 prepared by Donald G. Feller, R.A. After physical inspection, it was realized that the dwelling is a renovated 70+ year old structure which was exposed to weather conditions on the north side of the home. The proposed new construction measures 44' x 7', leaving a 9 ft. setback from the lot line facing Fifth Street. The new porch construction is one-story in height and maintains the same setback as the existing house. The renovation and rehabilitation are necessary and will create no impact on surrounding properties. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The dwelling has existed for more than 50 years in its nonconforming location and the reconstruction is needed for repairs and upgrade. The new construction is in-place, in-kind renovation of the pomhes and construction of alternative roof design, for which a variance is needed to complete. 3. The relief requested is substantial because the code requires a minimum 50 ft. front and the relief is for a 9 ft. setback from the lot line facing the area noted as Fifth Street. Although the house has existed in the present location for over 70 years, the variance will authorize a reduction of 41 feet from the setback requirement. 4. The difficulty was self-created in that this area could have been addressed in 1999- 2000, during the major renovations that took place when the applicant took title. 5. No evidence has been submitted to suggest that the relief granted herein will have an adverse impact on the physical or environmental conditions in the neighborhood. The construction is landward of the existing dwelling and does not affect the adjacent waterfront areas. 6. Grant of the alternative relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a new porch addition with alterations, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. ,~age 3 - August 7, 2003 Appl. No. 5382 - W. and D. Goggins 117.-10-14.1 at New Suffolk RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Goehringer, seconded by Chairwoman Tortora, and duly carried, to GRANT the variance as applied for, as shown on the May 6, 2003 plan prepared by Donald G. Feiler, R.A. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate,the Zoning Code, other than such uses, setbacks and other features as are expressly a/dressed in this action. Vote of the Board: Ayes: Members Tortor, a/(C~in,~ma/~),.~Goeh~ger, Orlando, and Oliva. (Absent was Member Homing.) T~ Re~l~ ~,y ~opted (4-0). Vi~eBt ~rla~ ~irm~n Pro Tern 9~4~03 Approved for Filing APPEALS BOARD MEMBERS Ruth D. Oliva, Chair~voman Gerard P. Goehringer Lydia A, Tortora Vincenl Orlando James Dinizio, Jr. http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS, DELIBERATIONS AND DECISION MEETING OF NOVEMBER 4, 2004 Southold Town Hall 53095 Main Road P.O. Box 1179 Southotd, NY 11971-0959 Tel. (631) 765-1809 Fax (631) 765-9064 RECEIVED !5 2O04 Sou hold Town Clerk Appl. No. 560t - WILLIAM and DONNA 1 Property Location: 1780 Jackson and Fifth Streets, New Suffolk; Pame1117-10-14.1 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 41,206 sq. ft. parcel is improved with a two-story wood frame dwelling, garage (under construction) and swimming pool (under construction), as shown on the survey prepared by Stanley J. leaksen, Jr. dated October 21, 2002. The property combined the parcels as CTM 14.1, previously shown as 13 and 14 on the Suffolk County Tax Map to form a single lot. (For the record it is noted that the former Accessory Bed and Breakfast was removed and is no ~onger In effect.) BASIS OF APPLICATION: This application is based on the Building Department's August 30, 2004 Notice of Disapproval concerning additions with alterations to the existing dwelling. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on October 21, 2004 at which time written and oral evidence was presented. Based upon all testimony, documentation, personal inspection of the property and the area, and other evidence, the Zoning Board finds the following facts to be true and relevant. ~: Applicants request variances under Zoning Code Sections 100-30A.3 Bulk Schedule and 100-242A, concerning a building permit application for additions/ alterations, as built, to applicant's home. The permit was denied by the Building Department for the following reasons: (1) the dwelling Is nonconforming with a 5.9 ft. front yard setback and the addition will maintain that setback, constituting an Increase in the degree of nonconformance of the code required 50 ft. front yard setback, and (2) the code limits a dwelling to 21/= stories, and the construction constitutes a third story. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted, and personal Inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the neighborhood or a detriment to nearby properties. The applicants' home was built about 50 years ago. The restoration of the home commenced in or about September 2003, after issuance of a building permit (29726Z) for construction of a covered porch and roof repair. During restoration, structural problems were found, and based on the advice of the engineer, additional work Page 2 - November 4, 20 Appl. No. 5601 -W. and D. Goggins 117-10-14.1 at New Suffolk was necessary for structural supports. In the restoration, work was undertaken to modify the height of the ceiling in the attic. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue. During the last couple of years, similar third story variance relief has been considered. The relief requested is for a modified ceiling/attic roof area, and the proposed restoration included the existing third floor. The applicants in this request indlcatad that they are not planning to use the upper third level for habitable or living area. 3. The variance is not substantial. A third-story living or habitable area does not exist and will not be created. The requested increase of nonconformance is related to the a third level, above 2-112 story height, and not the code restricted 35 ft. maximum building height. The roof addition is within the footprint of the building, maintaining the same setback without creating any new nonconformance in height or setbacks. 4. No evidence was submitted during the hearing or in the written record to indicate that this variance will have an adverse impact on the neighborhood or district. 5. Grant of the variance is the minimum action necessary and adequate to enable applicants to enjoy the benefit of an addition, while preserving and protecting the character of the neighborhood and the health, safety, and welfare of the community. BOARD RESOLUTION: in considering all of the above factors and applying the balancing test under New YorkTown Law 267-B, motion was offered by Member Dinizlo, seconded by Chairwoman Oliva, and duly carried, to GRANT the variance as applied for and described in the applicant's Auaust 18, 2004 architectural dia{~rems, SUBJECT TO THE FOLLOWING CONDITIONS: 1. The third-stow shall be non-habitable space, 2. The Board reserves the right to inspect in the future. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer Tortora, Orlando, and Dinizio. This Resolution was duly adop, ted)(5-0). A -. Ruth D. Oliva 11112/04 Approved for Filing Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD August24,2004 William Goggins ! 780 Jackson Street New Suffolk, NY 11956 Dear Mr. Goggins: Please be advised that we have received your proposed amendment to building permit #29726 for a porch addition and roof repair to an existing single family dwelling at 1780 Jackson Street, SCTM # 117-10-14.1. However, we are unable to approve the amendments, as proposed, without the following information: 1.) 2.) 3.) 4.) Wetlands Permits. Because the scope and nature of your project has changed and you are conducting activity within 100 and 300 feet of water~vetlands, r¢$p¢~tee and New York State~.~ment of Environmental Conservation approval is required. Approval from the Southold Town Zoning Board of Appeals. Although you were issued a variance from the ZBA, that variance was based on an application to construct a porch addition and to make roof repairs. Since the scope and nature of your project has changed, you must re-apply for a Notice of Disapproval from this office and re-apply for a variance from the ZBA, for setback and third story relief. The entire project will have to meet NYS code requirements. Certification of "basement area." It appears that the basement area of your home may meet the definition of a story. Please have your design professional certify that it does not constitute a story pursuant to the New York State Building Code. If not, certification from the ZBA will be required. Septic Certification. Because the scope and nature of your project has changed, septic certification is required from your design professional. Energy Calculations. Your design professional must submit energy calculations for this project. Because you have gone beyond the scope and nature of your original permit approval, a stop work order has been issued requiring the cessation of all construction until you have addressed the above referenced issues and have obtained a valid building permit for same. If you have any questions, please feel free to call this office at (631) 765-1802 between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Michael Verity, Chief BuiFding Inspector CC: Files Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631 ) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTI-IOLD August 24, 2004 William Goggins 1780 Jackson Street New Suffolk, NY 11956 Dear Mr. Goggins: Please be aware that your building permit (#29726Z) dated September 11, 2003, has expired and you are still in violation of Southold Town Code. As you know, the construction that has occurred on your property has yet to be approved by this department and you are occupying the property without the benefit ora certificate of occupancy. As you know, it had come to our attention, in early 2004, that the above referenced project had gone beyond the scope of the above referenced permit. In August 2004, you submitted amended drawings showing the complete scope of work. On August 24, 2004, a letter was issued by Chief Building Inspector Michael Verity, which expressed the need for a number of approvals and items required to amend the permit. Although you have satisfied most of those requirements and submitted most of the information we requested, we are still not in possession of an approval from the New York State Department of Environmental Conservation. Because your permit has expired, we respectfully request that you renew it immediately by sending a check in the amount of $150. Please be aware that, once the permit is renewed, the following will be required: 1. NYS DEC approval for the full scope of work done on the property. Once we have received DEC approval we will amend the permit based on the plans submitted to this office on August 19, 2004. Please be aware that once the amendment has been issued, the following will be required: 1. An additional fee for the amended permit. 2. An inspection of the property by a building inspector from this office. 3. Certifications from a New York State architect or engineer at the inspector's discretion. We respectfully request that you address this situation in a timely fashion. We are sorry for any inconvenience this may cause. If you have any questions, please feel free to contact this office as soon as possible, at (631) 765-1802, between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Damon Rallis, Permit Examiner CC: File, Ed Forrester April 20, 2004 WILLIAM C. GOGGINS DONNA M. GOGGINS P.O. Box 65 .J~lattituck, New York 11952 (631) 298-4200 Southold Town Building Department 53095 Main Road Southold, New York 11971 Dear Sirs: In response to your letter dated April 13, 2004, we are not performing construction work that requires a pe~t on our accessory garage. Please be advised that in the past two (2) years, several people in the Hamlet of New Suffolk, including a women named Shannon Simon, have made over 20 unfounded, baseless and meritless claims against us to the Depmiment of Environmental Conservation, the Southold Town Board of Trustees, the Southold Town Building Depmtaient and the Southold Town Police Depafia~ent. No charges or violations have ever been issued because there has never been a basis for, or evidence that supports, any of the COi~laint$. The continued co,,!,laints to governmental agencies is done with the intent to coerce us into removing a bulkhead groin, which is difficult to traverse by beach walkers. This groin protects our land from being washed away by the ebb and flow of the fide. We refuse to remove it. They continue to use governmental agencies to harass ns. Shannon Simon is so obsessed with our property that after two years of trespassing we finally had to file trespass chares against her. If you have any questions, please do not hesitate to contact the undersigned. WCG\ WILLIAM C. GOGGINS, P.C. ATTORNEY AND COUNSELOR AT LAW P.O. Box 65 13105 Main Road Mattituck, New York 1 !952 Phone (631) 298-4200 Fax (63 !) 298-4214 August 19, 2004 Building Department of the Town of Southold Young' s Avenue Southold, New York 11971 Attn: Michael Verity WILLIAM C. GOGGINS DONNA M. PALMER Paralegal Re: Gog~ns; Permit No. SCTM No. 1000-117.00-10.00-014.001 1780 Jackson Street, New Suffolk, New York Dear Mr. Verity: In connection with the above referenced matter, please be advised that the work at the above referenced premises has exceeded the pemfit due to structural problems found during construction. We employed a civil en~neer to draft plans and supervise the work for safety and compliance with the New York State Fire Prevention and Building Code. Enclosed please find an amended application to Permit No. 29726Z together with three (3) sets of plato stm~ed by the civil engineer. If you have any questions or require additional documentation, please do not hesitate to contact me. Thank you. Very truly yours, WIIJJAlVl C. GOGGINS WCG/chi~ WILLIAM C. GOGGINS, P.C. ATTO RNEY AND COUNSELOR AT LAW P.O. Box 65 13105 Main Road Mattituck, New York 11952 Phone (631) 298-4200 Fax (631) 298-4214 WILLIAM C. GOGGINS August 27, 2004 Southold Town Building Department 53095 Main Road Southold, New York 11971 Atto: Michael Verity DONNA M. PALMER Paralegal Re: 1780 Jackson Street, New Suffolk, New York; William C. Gog~ns Dear Sir/Madam: Enclosed please find a check in the amount of $35.00 to be added to the amended Building Permit application previously submitted on August 19, 2004. Please issue the Notice of Disapproval as soon as possible so that we can apply for the necessary variances. If you have any questions, please do not hesitate to contact the undersigned. Thank you. WCG\ enclosures Very trjaly yours, C o WILLIAM C. GOGGINS, P.C. ATTORNEY AND COUNSELOR AT LAW 13105 Main Road P.O. Box 65 Mattituck, New York 11952 Phone: (631) 298-4200 Fax: (631) 298-4214 WILLIAM C. GOGGINS November 12, 2004 Southold Town Building Department 53095 Main Road Southold, New York 11971 Attn: Michael Verity DONNA M. PALMER Paralegal Re: 1780 Jackson Street, New Suffolk, New York; William C. Gog~ns Dear Mr. Verity: Enclosed please find the Decision fi.om the Zoning Board of Appeals dated November 4, 2004, and the Trustee Permit dated September 22, 2004. All departmental approvals have been secured for construction. Please issue the Building Permit. As to the bay side deck, we should have the letter of non jurisdiction within the next few weeks. The topographical survey reflects that the house and deck are 14 feet above sea level removing the DEC from jurisdiction. If you have any questions, please do not hesitate to contact the undersigned. Thank you. WCG\ enclosures Veryffuly yours, GOGGINS & PALUMBO ATTORNEYS AND COUNSELORS AT LAW 13105 Main Road P.O. Box 65 Mattituck, New York 11952 Phone: (631) 298-4200 Fax: (631) 298-4214 WILLIAM C. GOGGINS May 19, 2006 Building Department of the Town of Southold Young's Avenue Southold, New York 11971 Attn: Mr. Damon Rallis ANTHONY H. PALUMBO DONNA M. PALMER Paralegal Re: William C. Goggins SCTM No. 1000-117.00-10.00-014.001 1780 Jackson Street, New Suffolk, New York Dear Mr. Rallis: Enclosed please find a certification of James J. Deerkoski, P.E. that the framing, strapping, insulation and plumbing inspections were completed in accordance with code. Also, enclosed please find a certification that the space above the second floor is habitable space because of the ceiling height and the installation of the fire protection automatic sprinkler system WCG/chi~ Cc: Southold Town Attorney Very truly yours, WILLIAM C./GO~GINS GOGGINS & PALUMBO ATTORNEYS AND COUNSELORS AT LAW P.O. Box 65 13235 Main Road Mattituck, New York 11952 Phone: (631) 298-4200 Fax: (631) 298-4214 WILLIAM C. GOGGINS, ESQ. ANTHONY H. PALUMBO, ESQ. March 18, 2010 Building Department of the Town of Southold P.O. Box 1179 53095 Main Road Southold, New York 11971 TRACY L. KARSCH, ESQ. DONALD A. MATES, ESQ. Of Counsel DONNA M. PALMER Paralegal Re~ 1780 Jackson Street, New Suffolk, New York a/k/a 8755 Fifth Street, New Suffolk, New York; SCTM No. 1000-117.00-10.00-014.001 Dear Sir/Madam: In connection with the above referenced matter, enclosed please find the following: 1. Application for Certificate of Occupancy; 2. Plumber Certification; and 3. Check in the amount of $25.00 as and for the fee. If you have any questions, please do not hesitate to contact the undersigned. Very truly yours, WCG/dmp enclosures GOGGINS & PALUMBO ATTORNEYS AND COUNSELORS AT LAW P.O. Box 65 13235 Main Road Mattituck, New York 11952 Phone: (631) 2984200 Fax: (631) 298-4214 WILLIAM C. GOGGINS, ESQ. ANTHONY H. PALUMBO, ESQ. April 5, 2010 Building Department of the Town of Southold P.O. Box 1179 53095 Main Road Southold, New York 11971 TRACY L. KARSCH, ESQ. DONALD A. MATES, ESQ. Of Counsel DONNA M. PALMER Paralegal Re: 1780 Jackson Street, New Suffolk, New York a/k/a 8755 Fifth Street, New Suffolk, New York; SCTM No. 1000-117.00-10.00-014.001 Dear Sir/Madam: In connection with the above referenced matter, enclosed please find the Electrical Inspection Certificate dated April 1, 2010. Thank you. WCG/dmp enclosures May 12, 2010 WILLIAM C. GOGGINS P.O. Box 65 Mattituck, New York 11952 (631) 298-4200 BLDG. DEPI, TOWN OF SOUTBOtD Building Department of the Town of Southold P.O. Box 1179, 53095 Main Road Southold, New York 11971 Attn: Michael Verity Re: 1780 Jackson Street, New Suffolk, New York a/k/a 8755 Fifth Street, New Suffolk, New York; SCTM No. 1000-117.00-10.00-014.001 Dear Mr. Verity: I submitted an application for Certificate of Occupancy and all documentation required for the issuance of a Certificate of Occupancy. As of today, I have not received the Certificate. Please be advised of the following sequence of events: On March 11, 2010, at my final inspection, the Building Inspector raised five (5) issues: 1. A second kitchen in the basement needs approval. 2. Dryer vent must be metal. 3. Need access to attic. 4. Need access to garage. 5. Electric and Plumbing certificate required. On March 15, 2010, the Building Inspector arrived to determine compliance with the above issues: 1. I showed the Inspector a copy of the 1990 Certificate of Occupancy, which is for a two (2) family dwelling with a seasonal apartment. 2. I showed the Inspector that the dryer vent was replaced with metal. 3. I made an access area hole in the ceiling of our bathroom. I provided the Inspector with a ladder, and I held it for him while he climbed up to take a look. He said he saw a wall, sheetrock and a wire. 4. Before the Inspector left the house, the Inspector said he needed access to the garage. I informed the Inspector that I already have a Certificate of Occupancy for the garage, and the final inspection was for the renovations to the house as applied for not the garage. I denied him access. The Inspector became irritable and demanded access. I refused. With all due respect, the Building Inspector does not have a right to access my garage. 5. I provided the Building Department with the Plumbers Certificate and the Electrical Certificate. The inspection report dated March 15, 2010 states: "Dryer vent is now metal. Attic has walls, sheetrock & wiring. Attic must be returned to non-habitable space, remove all walls, sheetrock, wiring, etc. ZBA approval dated November 4, 2004, #5601, states"l.The Third story shall be non-habitable space, 2. The Board reserves the right to inspect in the future." As of this date (6 years later), the ZBA has shown no interest to inspect my house, and I am not sure if their reservation to inspect is permissible under the law. Therefore, the only reason that the Building Department is apparently refusing to issue a Certificate of Occupancy for the renovations to my house is because it is claimed that the wall, sheetrock and wire in the attic/third floor makes it habitable space. Not true. The only access to the third floor is a ceiling access opening. In order for the space to be habitable, there must be stairs to make it accessible for habitation purposes. See, Sections 713.1 and 714.1 of the New York State Uniform Fire Prevention and Building Code. Moreover, all attics have wire, and some have walls and sheetrock. Such items do not arise to the level of habitable space. Yesterday, I spoke to Code Enforcement Officer, who informed me that he was intending to violate me for living in the house without a Certificate of Occupancy, and that the Certificate of Occupancy for the house would not be issued unless access was given to the garage. I do not understand where the hostility comes from. I do not understand the reluctance in issuing a Certificate for the renovations as applied for since I have always had a good relationship with you and the Enforcement Officer. I hope that this is merely a misunderstanding. 2 I respectfully ask that you issue the Certificate of Occupancy as applied for. The third floor/attic is not habitable because there is no access to it other than through a small access hole in the ceiling of the second floor. If you decide not to issue the Certificate of Occupancy, then please send me a letter setting forth the basis of your decision not to issue the Certificate of Occupancy. Thank you. William C. (Jogg~/~ 3 GOGGINS & PALUMBO ATTORNEYS AND COUNSELORS AT LAW P.O. Box 65 13235 Main Road Mattituck, New York 11952 Phone: (631) 2984200 Fax: (631) 298-4214 WILLIAM C. GOGGINS, ESQ. ANTHONY H. PALUMBO, ESQ. June 14, 2010 Building Department of the Town of Southold P.O. Box 1179 53095 Main Road Southold, New York 11971 Attn: Chief Building Inspector Michael Verity TRACY L. KARSCH, ESQ. DONALD A. MATES, ESQ. Of Counsel DONNA M. PALMER Paralegal Re: 1780 Jackson Street, New Suffolk, New York a/k/a 8755 Fifth Street, New Suffolk, New York; SCTM No. 1000-117.00-10.00-014.001 Dear Sir/Madam: In connection with the above referenced matter, enclosed please find the Certification that the window at the second floor bedroom on the northeast side meets the standard for egress. Thank you. WCG/dmp enclosure V~yours,, WILLIAM BLDG. DEP[ TOWN OF SOUTHOLO GOGGINS & PALUMBO ATTORNEYS AND COUNSELORS AT LAW P.O. Box 65 13235 Main Road Mattituck, New York 11952 Phone: (631) 298-4200 Fax: (631) 298-4214 WILLIAM C. GOGGINS, ESQ. ANTHONY H. PALUMBO, ESQ. June 15, 2010 Building Department of the Town of Southold P.O. Box I 179 53095 Main Road Southold, New York 11971 Attn: Chief Building Inspector Michael Verity TRACY L. KARSCH, ESQ. DONALD A. MATES, ESQ. Of Counsel DONNA M. PALMER Paralegal ge~ 1780 Jackson Street, New Suffolk, New York a/k/a 8755 Fifth Street, New Suffolk, New York; SCTM No. 1000-117.00-10.00-014.001 Dear Mr. Verity: In connection with the above referenced matter, enclosed please find the Certification that you requested. Thank you. Verv truly yours, WILLIAM C?GO~INS WCG/dmp enclosure 2010 BLDG. DEPT, TOWN OF SOUTHO~.D ' o'cal Criminal Court TOWN OF Southold Docket No. (s) VIOLATION INFORMATION STATE OF NEW YORK ) COUNTY OF SUFFOLK ss TOWN OF SOUTHOLD ) William Q Gogglns 8755 New Suffolk Road New Suffolk, NY 11956 ) Defendant(s) The undersigned Town Employee of the Town of Southold, being duly sworn, says that On and before May 13, 2010 at 8755 New Suffolk Road, New Suffolk, Town of Southold, County of Suffolk, State of New York, the defendant William C. Goggins wrongfully, intentionally, knowingly, recklessly, with criminal negligence, committed the offense of violating Southold Town Code Section 144-15. § 144-15. Certificate ofoccupancyrequired; application. A. No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector. To wit; the defendant is living in a single family dwelling without a valid certificate of occupancy. This complaint is based on personal observation and records and files of the building department. SWORN TO BEFORE ME THIS Signature of Official Administering Oath Notary Public Title Town of Southold DAY OF ('~XO~ ,20 } ~ Notary Public, ~t~te of New York No. 011~U6185050 Qualified n ~'°mmission ExpkSesuff~lpkri?l,n, ~O~ // oeal Criminal Court TOWN OF Southold Docket No. (s) VIOLATION INFORMATION STATE OF NEW YORK ) COUNTY OF SUFFOLK ss TOWN OF $OUTHO/D ) William C Goggins 8755 New Suffolk Road New Suffolk, NY 11956 ) Defendant(s) The undersigned Town Employee of the Town of Southold, being duly sworn, says that On and before May 13, 2010 at 8755 New Suffolk Road, New Suffolk, Town of Southold, County of Suffolk, State of New York, the defendant William C. Goggins wrongfully, intentionally, knowingly, recklessly, with criminal negligence, committed the offense of violating Southold Town Code Section 144-8(A)1. § 144-8. Building permit required; application for permit. A. Building permit required prior to commencement; exceptions. (1) No person, firm or corporation shall commence the erection, construction, enlargement, alteration, removal, improvement, demolition, conversion or change in the nature of the occupancy of any building or structure, or cause the same to be done, without first obtaining a separate building permit from the Building Inspector for each such building or structure. A building permit shall be required for any work which must conform to the Uniform Code, and Energy Code, except that no building permit shall be required for: To wit; the defendant did make alterations to an existing non-habitable accessory building, converting it to habitable space, without first obtaining a building permit. This complaint is based on personal observation and records and files of the building department. SWORN TO BEFORE ME THIS / ~3t'~ DAY OF Signature of Official Administering Oath Notary Public Title Town of Southold (h~ox~ ,20 Io . CONNIE O. BUNCh Notary Public, State of New Yor~ No. 01BU6185050 Oual/f/ed in Suffolk Coun ,. Commission Expires April 14, ~'0_/oX 'TO¥~N OF SOUTHOLD Southold, New York, 11971 Issued to: APPEARANCE TICKET- 1379 commission of the offense ~f: Last Neme First Name M.I. Number and Street Cay or Town Stet~ 2]p YOU ARE HEREBY directed to appear at the Justice Court, Town of Southold (Town Hall) 53095 Main Road ~ (State Route 25), Southold, New York 11971. ·Onthe IH dayof 20 at i o'clock in the O. M. in connection with your alleged IF YOU FAIL TO APPEAR ON THE DATE AND TIME WARRANT FOR yoUR ARREST MAY BE ISSUED. lid P.o. con~'ary to thc provisions of Section lqq- of the code of the Town of Southold Dated: B--/}'~ }l O I Issued and subscribed by: INDICATED, A OBI~INAL SUmmONS OB TOWN OF SOUTItOLD Southold, New York, 11971 APPEARANCE TICKET- 1380 Issued to: commission of the offense of: 60~,GItO g (~ Icct~ Last Name First Name M.I. C~ or Town ~le ~p YOU ARE HEREBY directed to appear at the Justice Court, Town of SoUthold (Town Hall) 53095 Main Road (State Route 25), Southold, New York 11971. Onthe Iq~'~'' dayof ~.~L)~e 20 ~O at t o'clock in the ~' m. in connection with your alleged IF YOU FAIL TO APPEAR ON THE DATE AND TIME WARRANT FOR YOUR ARREST MAY BE ISSUED. con~'ary to the provisions Section Iqq of the code of the Town of Southold Dated:' Issued an~ subscribed b'~ INDIGATED, A GRIMINAL SUMMONS OFI TOWN OF SOUTHOLD Southold, New York, 11971 APPEARANCE TICKET- 1381 Issued to: Last Name Number and Street commission of the offense of: comxaxy tO ~e pr_oVi/sixon~ .of Au~ 27 04 02~lGp BOARD OF ASSESSORS G3176~13~6 p.1 Robert I. Scott Jr., Chairman Scott A. Russell, Assessor Darline J. Duffy, Assessor Southold Town Hall, 53095 Route 25 EO. Box 1179 Southold, NY 119714)959 Fax: (631) 765-1356 Telephone: (631) 765-1937 BOARD OF ASSESSORS TOWl'q OF SOU'PIIOLD MEMORANDUM To: From: Re: Date: Mike Verity, Building Department Scott Russe~ssessor 1000-117-10-14.1 August 27, 2004: The owner of the above referenced property, William Goggins, has asked me to review the property card and convey any findings with regard to the bulk heading. An inspection of the property by this office on February 10, 1966 indicates that there was 75 feet of bulk heading which was noted by the Assessor and included in the land assessment. The assessment for the bulk heading has been included in the land value since that date. If you have any questions, do not hesitate to contact me. OR GINAL ..... } D TOWN BOARD OF Al'PEALS API,I,ICATION TO 1111,; SOU I I1( I 10-40 ,4CTM 0)Section 117 IIloclt lOl.,ol(s) 1~ I o Size 1.2 7.olteDIsh'icl ........ .... . ..... BUILDIN(, INS1 ~[-I OR I (W~) AI?~AL TIlE WIOTTE~ DET~I~IINA 1 I(.)N O1' I lie W~llt~m G- GoBBI~ ........ Appllcant/Owum'(~): ....................................... i~[ailing Address: P.O. Box 65, Mattituck, New York 11952 Telephone: 63_~1-298-4200 Authorized Represetdat~v ,: .... GO~IN$, WILLIAM & DONNA 5601 JD .... AS BLT ADDNS/ALTS FYSB & +2.5 S~S 1780 dAGKSON g 5TM N SUFF qiT-i0-~4A Tclel~hone: Please specify who yo~.s wish correspondence Lb I~e mailed Io, fl'OIII thc nbovc listed ~ Al~plicanl/Owuer(s) [3 Aulhorized Represeulativ~ ( Ihe ' _ ................. FOR: ~ Buliding l'ermll F3 Certificate of ()ccupmtcy ~ pre-Cerlificate of Occupancy t_l (?hauge of Usc I.I Permit for As-Built Conslruction [I Other: ......................... ProvisionoflheZ,ni"g r nceAppealed. Indic,teA~iltle, Secli"n, Subst*cfi°n of 7.ollhlg OrdinallCe by iIiinlbers. I)o ilot quoht Ihe Art cie ~IV ..... Section 100- 100 S bsecl an 2~2 A Article IIIA Section 100- Subsection 30A.3 Type ol Appeal. AnApl)eali~mndetor: ~1A Vnrinnce to Ihe ~ont.g Code or Zoning Mnp, [ 1A V~II'IRI ce due tn hwl~ of nccess required by Hex~ 1 I'k l own l,a~ ~cctu. 280-A. [I hderprelathm of rise I'* w ~ Co lc, A 't de .................... Sec o t I Reversal or Other A prior iq~penl~m~ has not been nmde n'lth respect I. (his In'operl~ IlNI)Ell Append ~, 53~.~__~ e, r._.~9.9.3 _. Page 2 of 3 - Appeal Application Part A: AREA VARIANCE REASONS (attach extra sheet as needed): (1) An undesirable change will not be produced In the CHARACTER of the nelghborhood or a dehlment to nearby properties, II granted, because: Variance is neede due to ceiling height of attic area, not height of. building. (2) The benefit sought by the applicant CANNOT be achieved by some method feasible for the applicant to pursue, other than an area variance, because: The structure was built with the belief that it conformed to existing zoning code. the foot print of the ' g and is therefore a side yard. (4) The variance wm NOT have an adverse effect or Impac! on the physical or environmental conditions in the neighborhood or dislflct because: The foot print w±ll not change. (5) Has the variance been selt-created? (×) Yes, or { ) No. If not, is the construction exisflng, asbullt? ( ) Yes, or ( ) No. Partially the construction is a renovation of existing building. (6} Additional Information about the surrounding topography and building areas that relate to the difficulty In meeting the code requirements: (attach extra sheet as needed) Thls is the MINIMUM that Is necessary and adequate, and af the same tlme pr,~serves and protects the character of the neighborhood and the health, safety, and welfare o! the community. ( ) Check this box and complete PAR! B, Qupsflons on next page to apply~ ~. (Please consult your aftorney? 9~herwlse../~leas' I~)~ved to the slanatur, ~.thls :~gg~gnea/nf f~u rx/~' uO~s~ ~~~wn tn e r ) -- . September nnn 4 WILLI~ C. GOGGINS ls~ay o~ .................... zuu_. (Nota~ Public) ELAINE T. VILLANO N~t~IY Public, State of New ~lt~ll~02922g. Suffolk Cou~nt~,. ~"j'~Y',Y~,o~ Exoims Aug, 9, ~ Page 3 of 3 - Appea~ Application Part B: REASONS FOR USE VARIANCE (lf reauested): For Each and Every Permitted Use under the Zoning Regulations tot the particular District Where the Prolect Is Located (please consult yo'ur attorney belore completing): 1. Applicant cannot realize a reasonable return for each and every permitted use under the zoning regulations for the particular dishlct where the property is located, demonstrated by competent flnancla~ evidence. The appllcanl CANNOT realize a REASONABLE RETURN because: (des¢flbe on a separate sheet)· 2. The alleged hardship relating to the property is unique because: The alleged front yard ts in fact the side yard and before the merger law the property was conforming; and because the road does not run paralell to area of property where house is located. 3. The alleged hardship does not apply to a substantial portion of the district or neighborhood because: This is a unique property 4. The request will not alter the essential character of the neighborhood because: The interisr of the building has changed causing a violation of the ~own Code 5. The alleged hardshlR has not bet~ self-created because: Building~as existe'~ ~or over ~u years, aha the change is within the footprint other than the porch above concrete slab. 6. This is the minimum relle! necessary, while at the same time preserving and protecting the character of the neighborhood, and the health, safety and welfare of the community. (Please explain on a separate sheet il necessary.) 7. The spirit of the ordinance will be observed, public safely and welfare will be secured, and subsfanllal Justice will be done because: (Please explain on a separate sheet II necessaly.) The code does not contemplate ~he circumstances of this application . ( ) Check this box and complete PART A, Questions on previous page to apply AREA VARIANCE STANDARDS. (Please consult your attorney.) Otherwise, 13lease prqceed to the slanature and notaw area below. Sworn to before me this I st day of ..S.e. £.c.?~.e.? ..... 200_4. (Notary Public) Signature of Appella~ ~, ~v,,,,, ...... gent (A.g?.nf~ ~u~f su~b~n~t,~.ufboflzaflon from Owner) ELAINE T. VII. t.A~O Notmy Public,, ~tMe of New Yo~ ZBA App ~WNER TOWN OF $OUTHOLD PROPERTY RECORD CARD vILLAGE SUB. LOT IMP. ¥OTAL ,,'bATE Goo d~l~ · ~, TYPE OF BUILDING Wp'~'ff~ ~+, COMM. CB. MISC. Mkt. Value REMARKS AGE ,lEV/ :ARM BUILDING CONDITION NORMAL BELOW ABOVE Acre Value Per Value 2 liable 3 'oodland vamplond 'us~land ouse Plot FRONTAGE ON WATER ROAD )EPTH BULKHEAD /'~<3 DOCK M. mdg. Extension Extension Extension ' Porch Porch Breezeway C~rage Potio F 2-/! Bosement ~'u// ~A Ir. Ext. Walls ~ ~, .~ ~ Interior Finish Place ~ Heat E~f ~'/ E~ms 1st Flor Rooms 2nd Floor Driveway SEAS. VI LLAGE CB. J MISC. · AGE NEW Farm Tillable Tillable 3 Wcodland Swampland Brushland House Ptot Total IMP. NORMAL Acre TOTAL DATE BUILDING CONDITION BELOW Value Per Acre cOMM. J IND. ABOVE Value M. Bldg. Extension j Foundation Extension Exte! ,~lon Porci Breezew~ Ext. Walls Fire Place Patio Driveway Porch Bath Floors In*~rior Finish Hera' Attic ROoms ]st Floor Rooms 2nd Floor NAME ADDRESS P.o. ,q'ox .~'c~ ~ PItONE~ '7,,~,~- -7.l~"7. HOW RECEIVED, TEL MAIL__ IN PERSON__ LOCATION OF COMP AINT REPORT ~/~4 o,,/ ~z'-z o DATE o~p~o~ ASSIGNED TO INSP. DATE REi~SARKS ACTION TAKEN FILE # (IF APPLICABLE), RE-INSP DATE The following observations have been made by neighbors of William C. and Donna C. Goggins on Jackson Street, New Suffolk (TM 1000-117-I0-14), subsequent to the issuance of Certification of Occupancy No. Z-29852 in November, 2003: Neighbors have reported the following work being done at the Gogg/ns garage structure. Sheetrock deliveries and spackle buckets have been seen in the garage area. Utility company employees were seen on the site and said they were installing gas lines. Sheetrock was seen being lifted from a truck to the upper floor above the garage. Erection and painting of partitions on second floor of the garage structure was observed through windows. Painting of walls in the first floor area at the side sections adjacent to the garage bays was also observed at night. Painting in the interior of the north and south wings was observed at nights of March 8th and 9th 2004, respectively. For several months prior to this complaint, the windows on the east and north side above the garage painters' were covered by tarpaulins, apparently put to prevent neighbors from seeing construction being carried out inside. A truck beating the sign of Kolb's heating and air-conditioning service was observed in the driveway on March 20, 2004. Floor-sanding equipment was brought into the structure early in the morning of Sunday, March 21, 2004. The sound of sanding machinery could be heard from the street as well as from adjacent properties throughout much of the day. MICHAEL ARTHUR SIMON Attorney at Law 17130 Main Street P. O. Box 303 New Suffolk, New York 11956 Phone: (631)734-7237 Fax: (631)734-7080 August 13, 2004 Michael Verrity Building Department Southold Town Hall Southold, New York 11971 Dear Mr. Verrity: It has come to the attention of a number of New Suffolk residents that proper work permits have not been obtained for the work currently being done on the house belonging to William Goggins on Jackson and Fifth Streets in New Suffolk Inasmuch as there is considerable evidence that this work has placed the property in significantly greater noncomformity with the Code, we are asking that a Stop Work Order be granted immediately and remain in effect until all necessary variances and permits are obtained~ Yours sincerely, Michael A. Simon Thomas C. Samuels cc: Supervisor Horton From: Concerned New Suffolk residents To: Mike Verity Southold Town Building Department Dear Mr. Verity, I want to express our confusion and conce,_'n .,'Jout the way in which the $outhold Town Building Department and the Board of Tro~'t~ es selectively enforce the building code. We are referring to the new home constr,.~c, tion ?,t the southeast end of New Suffolk Road (Fifth Street) in New Suffolk. We have cv~;~iv~ed that this new home construction is occurring without the proper permits. Penni~, dated from 2003 encompass only a new pool and small porch facing .rackson Street. This home has been demolished and is being built anew. Why is this permitted? We un&:stand that the law states a builder who knowingly conducts work of this magnitude withow, the proper permits can lose his license. Why do these builders have immunity? What is the owner - William Goggins' relationship with the Town and/or the Trustees which allows him to cireumvem the law? It is disturbing that Mr. Goggins, a prominera :.~omey in the Town of Southold with apparent connections within the building de?/,ment and the Boant of Trustees. receives favorable treatment from the Town to cons¥~:6t an illegal rasidenee above his garage, and build a new home (with an additional floor), without the proper permits. Another flagrant disregard for your office ,md t?.e approval process is the initial construction of a third floor bayside sun deck. ',Vhile plans for two other bayside decks have been submitted for review by the Tru3te¢;s at their 8/18 meeting, this third slrneture has not been accounted for. The foregoing facts give thc impression that knowk~g the right people in the $outhold Town Building Department gains privileges that the rest of the taxpayers do not enjoy. What is known: There is an illegal residence above the garage. Runoff from this illegal residence is damag!.~ aeighbors' property. Building is ongoing without proper permits. The new home (which now has three floo:'~ as opposed to two) has now become the tallest structure in New Suffolk. What is unknown: Why Mr. Ooggins is able to disregard the b~,ilding code? Why these actions are permitted? Why the builders have immunity? What you are going to do about it? Although we have chosen to remain anonymous for fear of reprisal from Mr. Ooggins, we do not intend to drop this matter without your prompt action. We do not wish to personally engage in any additional unpleasant confrontations with Mr. Goggins - bis connections are evidently far r~aching. Concerned New Suffolk residents CC Chris Talbot - Building Inspector Gary Fish - BuildinS Insp~tor Georgia Rudder - Head Clerk Connie Bunch - Senior Clerk Typist Pat Conklin - Plans Examiner Damon Rallis - Plans Examiner Robert Fisher - Fire Safety Inspector Ooorgia Rudder Albert J. Knipski, Pr~si~n! James King, Vice-President Peggy A. Dickerson Attic Foster Ken Poliwoda Editor - Times Review Editor- The Traveler Wa~clunan Editor - Suffolk Times Kenneth p. LaVallo - 1st Senate District Pafficia L. Acampora - I st Assembly Di$~ct Christine Malafi - County Attorney Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765~951~' Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF $OUTHOLD STOP WORK ORDER TO: William C. Goggins & Donna Goggins P.O. Box 65 Mattituck N.Y. 11952 YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK AT: 8755 New Suffolk Road, New Suffolk TAX MAP NUMBER - 1000-117.-10-14.1 PURSUANT TO SECTION 45-10B OF THE CODE OF THE TOWN OF SOUTHOLD, NEW YORK, YOU ARE NOTIFIED TO IMMEDIATELY SUSPEND ALL WORK AND BUILDING ACTIVITIES UNTIL THIS ORDER IS RESCINDED § 45-10. Performance of work underpermit. B. The issuance of a building permit shaft constitute authority to the applicant to proceed with the work in accordance with the approved plans and specifications and in accordance with the Uniform Code and applicable building laws, ordinances or regulations. All work shaft conform to the approved application, plans and specifications. Pursuant to §45-13 of the Code of the Town of Southold; Construction at the above referenced location does not conform with the approved application for which Buildin.q Permit # 29726Z was issued. And you are hereby notified to suspend all work and all buildin,q activities until which time this order has been rescinded. Conditions under which work may be resumed; The issuance of a valid building permit for work heretofore completed and any additional work to be done. Furthermore Building Permit # 29726Z is hereby revoked pursuant to Southold Town Code Section 45-12C which states; § 45-12. Revocation of building permit. The Building Inspector may revoke a building permit theretofore issued and approved in the following instances: C. Where he finds that the work performed under the permit is not being prosecuted in accordance with the provisions of the application, plans or specifications. FAILURE TO COMPLY WITH THE APPLICABLE PROVISIONS OF LAW MAY CONSTITUTE AN OFFENSE PUNISHABLE BY FINE IMPRISONMENT OR BOTH. DATED: Michael J. Verity Chief Building Inspector Permit Number REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSottware Version 3.6 Release 1 Data filename: Untitled.rck Checked By/Date PROJECT TITLE: RENOVATION COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Mutfifamily HEATING TYPE: Non-Electric WINDOW / WALL RATIO: 0.17 DATE: 08/17/04 DATE OF PLANS: 8/2004 PROJECT DESCRIPTION: CA)C~INS RESIDENCE IqFIH STREET COMPLIANCE: Passes Maximum UA = 862 Your Home UA = 453 47.4% Better Than Cede (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-VMue R-Value U-Factor Ceiling 1: Flat Ceiling or Scissor Tress 1612 30.0 0.0 56 Wall 1: Wood Frame, 16" o.c. 1796 21.0 0.0 83 Window 1: Wood Frame:Double Pane with Low-E 98 0.300 29 Window 2: Wood Frame:Double Pane with Low-E 136 0.330 45 Window 3: Wood Frame:Double Pane with Low-E 13 0.340 4 Door 1: Glass 100 0.330 33 Wall 2: Wood Frame, 16' o.c. 1624 21.0 0.0 80 Window 4: Wood Frame:Double Pane with Low-E 100 0.300 30 Window 5: Wood Frame:Double Pane with Low-E 78 0.330 26 Window 6: Wood Frame:Double Pane with Low-E 42 0.340 14 Floor 1: All-Wood Juist/Tm:Over Unconditioned Space 1612 30.0 0.0 53 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of Iris/her knowledge, belief, and professional judgment, such plans or specifications arc in compliance with this Code. REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoPavare Version 3.6 Release 1 DATE: 08/17/04 PROJECT TrrLE: RENOVATION Dept. Us~ [ I [ I [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Tress, R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: 2. Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? [ ] Yes [ Comments: ] No Window 2: Wood Frame:Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? [ ] Yes [ Comments: ] No Window 3: Wood Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: # Panes Frame Type Tbennal Break? [ ] Yes [ Comments: ] No Window 4: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: # Panes Frame Type Tbennal Break? [ ] Yes [ Comments: ] No Window 5: Wood Frame:Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 6: Wood Frame:Double Pane with LOw-E, U-factor: 0.340 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No 1. Door 1: Glass, U-factor: 0.330 Comments: 1. Floor 1: All-Wood Joistfrruss:Over Unconditioned Space, R-30.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1 ) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5N clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, wails, and floors. Materials Identification: Materials and equipment must be installed in accordance with thc manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be ~ned. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and giazing U-factors must bc clearly marked on thc building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the bnilding must be insulated to R-4. Sopply ducts in unconditioned spaces must be insdaled to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R- Return ducts in unconditioned spaces (except basements) must be insolated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: Ail joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plns-cmbedded-£abric, or tapes. Tapes and mastics must be rated UL 18 lA or ITL 18 lB. Exception: Centinunnsly wekied and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Thc HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at leant one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate eleetric meters arc rcqnired for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-oombostible fireplace doors. Fizeplaces must be provided with a source of cambnstion air, as required by the Fireplace construction provisions of thc Building Code of New York State, the Residential Code of Ne~ York State or the Ne~ York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless thc water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot P/a~er Pipe~ Insulation Thicknc~.~ in lnehe~ bv Pi~ne Sizes Heated Water n- ' ' Circulatine Mains and Runoui,s Temnemture (F) Uo to 1" ~ 1.5" to 2.0" ~ 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minlmum lnsulat~on Tklckness for HVAC Pipe~ Fluid Temp. In~nlation Thickne~ in lnehe~ by Pine Sizes Heating Systems Low P~ssure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Comlensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Permit Number Checked By/Date REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSoflware Version 3.6 Release 1 Data filename: C:~rogram Files\Check~EScheck\GOGGINS.rck PROJECT TfI'LE: RENOVATION COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Muitifamily HEATING TYPE: Non-Electric WINDOW / WALL RATIO: 0.17 DATE: 08/25/04 DATE OF PLANS: 8/2004 PROJECT DESCRIPTION: GOGGINS RESIDENCE lqVll-I STREET CUTCHOGUE, NY COMPLIANCE: Passes Maximum UA = 862 Your Home UA = 453 47.4% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-V~ue R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1612 30.0 0.0 56 Wall 1: Wood Frame, 16' o.c. 1796 21.0 0.0 83 Window 1: Wood Frame:Double Pane with Low-E 98 0.300 29 Window 2: Wood Frame:Double Pane with Low-E 136 0.330 45 Window 3: Wood Frame:Double Pane with Low-E 13 0.340 4 Door 1: Glass 100 0.330 33 Wall 2: Wood Frame, 16" o.c. 1624 21.0 0.0 80 Window 4: Wood Frame:Double Pane with Low-E 100 0.300 30 Window 5: wood Frame:Double Pane with Low-E 78 0.330 26 Window 6: Wood Frame:Double Pane with Low-E 42 0.340 14 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 16t2 30.0 0.0 53 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed syslems have been designed to meet the New York Stag Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance with this Code. Builder/Designer ~"'~r~.~ ~ ~C..~f--~"R~ Date ~-~ REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoflware Version 3.6 Release 1 DATE: 08/25304 PROJECT TITLE: RENOVATION Bldg. Dept. Use [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Tress, R-30.0 cavity insulation Above-Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation 2. Wall 2: Wood Frame, 16H o.c., R-21.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame:Double Pane with Low-E, U-fac~r: 0.300 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ Comments: ] No Window 2: Wood Frame:Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ Comments: ] No Window 3: Wood Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ ] No Window 4: Wood Frame:Double Pane with Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ Comments: ] No Window 5: Wood Frame:Double Pane with Low-E, U-factor: 0.330 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ Comments: ] No Window 6: Wood Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: # Panes Frame Type. Thermal Break? ] Yes [ ]No 1. Door 1: Glass, U-factor: 0.330 Comments: 1. Floor 1: All-Wood Jois~Truss:Over Unconditioned Space, R-30.0 cavily insulation Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed~ Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials, ff non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-wimer side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooluig equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Inmlafion: Supply ducts in unconditioned attice or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R- Return ducts in unconditioned spaces (except basements) must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: Ail joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mantics must be mud UL 18lA or UL 18lB. Exception:Continoonsly welded and locking-type longitudinal joints and seams on duels operating at less than 2 in. w.g. (500 Pa). ~ HVAC system must provide a means for balancing air and wa~er systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set paint of the largest zone. Electric Systems: Separate electric me.rs are required for each dwelling unit. F~replaces: Fireplaces must be installed with tight tilting non-oombnstible fireplace doors. Fi~places must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipa risers mnst have a beat trap on both the iulet and outiet unless the water heater has an integral heat trap or is pa~ of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of thc heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 OF or chilled fluids below 55 °F must be insulated to thc levels in Table 2. Table 1: Minimum Insulation Tldckness for Circulating Hot Water Pipea Inmdation Thieknexi in lnche~ by Pine Heated Water ' 'n Circulatine Mainn and Runout~ Temnerature ( 1~ Unto 1' Unto 125* 1.5# to 2.0' Ova2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum lnsulotion Tkiclmess for HVAC Pipea Fired Temp. Insulation Thicknea~ in Inches by Pin~ .qi?e_~ Heating Systems Low Pressmcfremperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Re~igerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 ~ 2.5* to 4" NOTES TO FIELD (Building Department Usc Only) BUILDING PERMIT EXAMINER CFIECKLIST APPLICANT: (~L)C_~-_.A~,,- ~--~o~,..-< SCTM# DISTRICT: 1,000, SECTION: I I~ ~0 , LOT: DATE REVIEWED: ~ / c~ /03 DATE SUBMITTED: ~ /~:_/03 SUBDIVISION: CITY: DoztlQ(M~'~-jI~ ZONING DISTRICT: ~ CONFORMING? . i%9 , n,~FO , INFO BUILDING PERMITS OPEN/EXPIRED: PRE CO~R N BP~l$ -z / c/o z-O~ , n, rFO ~qCc~ / BP,_.qq~-z / c/o Z- BP -Z / C/0 Z- , INFO / BP -Z / C/0 Z- SINGLE & SEPARATE CERTIFICATION-REQUIRED /qo NOTES: LOTS 40,000SF -100-24. Lot recognition.(CREATED before June 30, 1983), UNDERSIZED LOTS FROM JAN.1997 100-25. Merger.(A nonconforming at any time after 7/118 REQ. LOT SIZE: ,40& ACT. LOT SIZ ' ~,F~ REQ. LOT COV.C: REQ. FRONT ~ PROP. FRON2' (,~'~.'q'~REQ SIDE ~ ACT. SIDE ( cO -- REQ. REAR - ~/ PROP, REAR PRmECT DESCRIPTION: 42o~ ESTIMATED PROJECT COST:~ / WAVER FRONT? m DESCRIPTION: ~'co,., c '~ ,'-;'4I PANEL # FLOOD ZONE: APPROVALS REQUIRED SUFFOLK COUNTY HEALTH ~..~PT: YES o~/NO,)(BED #): DTE: / /__ PERMIT #: TOWN SEPTIC RECEIPT: Y oNe) NEW YORK STATE DEC: PRE-DEC 9/1/75 YES or(~ DTE: __/ / SOUTHOLD TOWN TRUST-E-~.' YES o~3LO) DTE: ~ / TOWN ZONING BOARD APPROVAL¢(~ o~) 4~6J~% DTE: __/__/ TOWN PLAN. BOARD APPROVAL: YES or~ DTE: / / TOWN HISTORICAL PRE (SPLIA): YES PERMIT #: PERMIT #: PERMIT #: PERMIT #: NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2): YES or NO FEE STRUCTURE: FOUNDATION: FIRST FLOOR: SECOND FLOOR: OTHER: TOTAL: 1.( 3~ SF)-( 2. ( SF)- ( 3. ( SF)- ( SF)= SF X $ SF)= SF X $ SF)= SF X $ SF SF SF SF SF INIT OTHER TOTAL FEE FEE FEE =$ +$ +$ = $ =$ +$ +$ = $ =$ +$ +$ : $~ NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERLA_: Ground Snow Load:45 Weathering: Severe__ Wind Speed: 120MP/~. Seismic Design Category: B Frost Depth: 36" Termite: M-H Decay: S-M Design Temp: 11 Ice Shield Underlay: YES USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: J TYPE OF CONSTRUCTION: j DESIGN CRITERIA: ENGINEERED/P~-'~T1VE~_ FULL FRAMiNG DESIGN ELEMENTS~ Flood Hazards: HEADERS: Y/N WALL STUDS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS: Y/N LUMBER SPECIES AND GRADE: Y/N DESIGN LOAD CALCULATIONS'~ GIRDERS: Y/N ROOF RAFTERS: Y/N LIVE: YfN DEAD: Y/N SNOW: YfN SEISMIC: Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: MIS SLE TEST..,~EQUIREMENT~/N EGRESS Y/N LIG.T VENT NAILING/CONSTRUCTION SCHEDULE~N MEANS OF EGRESS~/N PLUMBING RISER DIAGRAM: Y~ ~'/.~ LOCATION OF FIRE PROTECTION EQUIPMENT: Y~ -~./~ TRUSS DESIGN: Y~ CERTIFICATION: Y~ ENERGY CALCS: Y~ TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) % L Of~O,e,,% 5EC. TION Jl Ct<SON S Tf EE T S 83' 48' 00" E 100. 10' TM 1000-117-10-13 AREA= 29,695.337 SF OR a682 ACRES eM N/F CROUCH N OVER S 83' 48' 00" 75. 0 5.9'~ DECK WI RAILING N 83' 48' O0 COND. SW PROP, 3 CAR GARAGE 20' 2 STORY WOOD FRAME RES. 21.8' DECK W/RAIL- LOF~ER LEVEL CONC. PA DO O,OO ZONE X KLOOD ZONE AS (EL. 8 ,H.K%, THI~eATE 75.01 STEPS N/F GOODMAN ROGERS N 83' 48' 00" W 24. 15' N/F GOODALE 1000-117-10-14 AREA= 11,510.729 SF OR 0.264ACREB MAP OF DESCRIBED PROPOERTY SITUATE NEW SUFFOLK TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. SURVEYED FOR WILLIAM C. DONNA M. GOGGINS GOGGtNS SURVEYED 21 OCTOBER, 2002 SCALE 1"=40' NOTE: FLOOD ZONE X FOR BOTH PARCELS EXCEPT AS SHOWN MAP# J610JCO501G MA Y 4, 1998 AREAS AND TAX MAP NUMBERS AS SHOWN. ZONED R-40 CF EA T PECON/C BA¥ GUARANTEED TO ~LL~M C. GOGGINB DONNA M. GOGGINS COMMONWEAL THLAND fl~E ~ CO. SURVEYED BY STANLEY J. ISAKSEN, JR. P.O. BOX 294 NEW,~SDFFOLK, NY 1195.5"') 631,__~, 754,,-55J5 . / ~7 /LICENS~LAND SU~EYOR NYS L~ NO. 4927~ 02R1187 DESIGN SERVICES __,_ L.L.! ~ ~ ~: ~ -- ¢/3 0 =- - I ......~ DRAWN BY: NH ~ ? ] SCALE: 1/4"= :['-0" FRONT ELEVATION ~° '" SHEET NO: DESIGN SERVICES : / , :~ i -: : i ~' :~ = draw4u@optonline.net ..-! r.O DRAWN BY:  June 21, 2006 SCALE: 1/4" = 1'-0" , , .... . SHEET NO: REAR ELEVATION RIGHT ELEVATION DESIGN SERVICES (63t) 298-2250 draw4u@optonline.net Z DRAWN BY: NIH LEFT ELEVATION DESIGN SERVICES (631) 298-2250 draw4u@optonline.net Z O DRAWN BY: MH ]une 21, 2006 SCALE: 1/4"= 1'-0" SHEET NO: b DESIGN SERVICES EXISTING DECK (631) 298-2250 EXISTING EXISTING DINING ROOM EXISTING/~ ~:~ OFFICE LIVING ROOM Z 0 , 00 EXISTING KITCHEN EXISTING ~ · ~,1,1~ FOYER [ _ EXISTING COVERED PORCH D~WN BY: MH  , June 21, 2006 ~ -~ ~ -~- -~S~LE: Z/." = ~'-0" SHEET NO: ZST. FLOOR P~N ~ISTING) SCALE: [/4" = ~'-0' DESIGN SERVICES (651) 298-2250 [, ,~ ~ ~, L ~ ,~ ,~ L : '~ " '~ '~ ~" " I draw4u@optonline.net BATH / EXISTING ~ ~ ~ BATH ~ BEDROOM ~ / ~ EX~ST~ /"~ EX~ST~,~ ~ ~ ~ OPEN / ~ ~ ~ EXISTING ~ BEDROOM EXISTING ~~~ - BATH D~WN BY: NH 2ND. FLOOR P~N ~ ~.~ ]une 2~, 2006 SCALE: I/4"= 1'-0' ~CALE: 1/~" = 1'-0" ~ , )i~ SHEET NO: BATH J EXISTING BEDROOM EXISTING /"~ EXISTING ~ - BEDROOM EXISTING BEDROOM EXISTING ~~~ BATH ~ ,, D~WN BY: MH _ ~ ~,~L EXISTING I~ ~ I I / ~ ~ ~ BASEMENT ~un~ 2~, 2006 , CROSS SE~ION ~ ,~,, SHEET NO: _RESIDENTIAL FIRE SPRINKLER SYSTEM ~q~'~ N~ ~ !~ ,?~ ~, ~ .~ .~¢~,.~ L,q! ~/~?S~?. draw4u@optonline, net < ~ ~ ~ ~ June 21, 2006 AR~NGEMENT OF SUPPLY PIPING WITH BACKFLOW D~CE AR~NGEMENT OF SUPPLY PIPING AND VALVES GENERAL NOTES WIND FRAMING NOTES NAILING SCHEDULE ~ PLAN CONTENTS: 11 RIDGE~O-RAFTERASSEMBLY' ROOF FRAMING: OCCUPANCY CLASSIFICATION I R3RESIDENTIAL CONSTRUCTION NOTES: Ineaahendofthar. ollarUenaad,o~exceedthetabulatmdnumbere[Sdnailslnlhes~-ap. R^FTERTO B'WALL;~SdCOMMON EACH TOE-NAIL 3) Dimensions ahaJl take pmaedent over scs]ed drawings. ROOMS (OTHER THAN SLEEPING) 40 d raw4u @opt:online. n et: 4). The daS~gl~er has not been en~aged for canstruc~on super vlsle]l and assumes no ~nne~ors Sl,,I simp, ,ha~l h,ve a ndrtlmUm embed[ne,[ of 7 Inches In ooncrete WALL F RAM I N G: -~U"ORA~LS (ANY DIRECTION) 200 FOUNDATION NOTES: FYPe II exte.~r sh.arWalls shall meal Ihe requirements er tabl. 3 15a-b times the appropriate BO~Ci'OM PLATE TO; L END JOISTORI3LOOKING FOOTS~NO~.~,~ CLIMATIC & GEOGRAPHIC DESIGN CRITERIA , leterm[neintendedhelghtsefflnished/leor~s)abevelyplc~lgr~de, '),INTERIORSHEARWALLCONNECTIONS,FLOOR FRAMING: ~.O~N~ W~.O S~SM~C ~.OS~ W~.~. ~C~SN$~O ~ ~ ~:~ HLDCKING ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: BLOCK NAIL 4' PERIMETER EDGE ~ONE 8d COMII~ON ~ ~' O C ad COMMON ~ 6" O.O, SEE NOTES' 1,3 ~ r~ · r16cast~ronfoundatlenvent[ereverylsosq, fl_e~area etlached ~[h the above requ#ement, TO 0HAM 3 - 16d COMMON JOIST NAIL I INTERIOR ZONE 8d COMMON S 6" O.C 8d COMMON ~ 12" O C. SEE NOTES' 1 ( BOTH FIELDS) I 7) Dsmpproofeaedoro[foundaflon~bitumineus~a,nga. psr~[onR4O6of DECK AND COVERED PORCH NOTES: JOISTONLEDGER 3-8~COMMON JOIST Dougla, Fir. 41. Oaablsm t9 have bio.lng aL 8'0 o ~. CEILING SHEATHING: ~mlnfl membem wire 042<G<04a, lb. nail spanlng shall be reduced to 3 In.es o ~ o~a~sa L~ger~blfa~t,n~tobulldln~wl~l~'dla. boltswl~wash~andnu~ JOINTDESCmmlO~ OW. S.~C,.~ WALL SHEATHING REQUIREMENTS FOR WIND LOADS: NAIL SPACING ~AIL SPACING AT INTE~ED]ATJ ope,leDs LVL h.ader, ta have (3)Ja~ studs a,d (2)~11 le.g~ .~ds on ea~ aide ~ WALL SH EATH IN G: s~ NOTES: 1.3 ( BOTH FIELDS] .A.E~S .. co~o. w~cM_s.c NOTES encham wham applicable to all ~nnealng joists PLUMBING NOTES ~) Pmvldabl~c~ng~ndglngm0~orjolsUa[8'0o~ Usesolldbbc~lnglnfloorjalas FLOOR SHEATHING: 2~Tabu~a~d121nch~c. na~spaanga~um~shaa~inga~edtos~df~mlngmame~w~h HVAC SYSTEM NOTES I"ORLESS D WN BY: HH 10).Unla~e~senotsduse~"thl~T&GPTSFirerAdvent~hp~dsubfleer 2) HVACsu~n~a~ls~[ully~lna~a~stemdamaudmqulmm~>~. MENTION~DtNSCHEDULENO~SONLY, ~ lane 2~t ~00~ ~lirngs~nUovarfuma~mhave~"thl~kt~xshae~o~.Alla~erp~sorbulldlng :on~mctoran~ownerfor~nalmvr~andapprovsl Isna]lad3"~-~mnt~ra[ths~nalsdge~oob~lnhlgherWALLSTOBEREMGVED : ~ SCALE: 1/4" = 1'-0" Lo h~a m~ular 1/2' ~hee~e~ NI walls to b~ taped and ,niGhed. ELECTRICAL NOTES: membsm sha~J be doub~ed, ~ all.ate ~n~sct~m, JOINT DESCRIPTION NAIL NAIL NOTES QTY ~PACING RAFTER TO S' WALL; ~8d COMMON EACH TOE-NAIL TOP PLATE 10' WALL' 4-~d COMMON {AFTER CEILING JOIST S' WALL. 3~8d COMMON EACH TOE-NAIL TO TOP pLATE ID' WALL' 4-6d COMMON JOIST CEILJNG JOIST TO AS PER TABLE 3 7 EACH FACE OCCUpANcY CLASSIFICATION R3 RESIDENTIAL BUILDING USE RESIDENTIAL DWELLING BUILDING HEIGHT AVG ' 41'~t" OVERALL (MEAN ROOF HEIGHT' tOTAL BQ FT. OF CONSTRUCTION ALTERATIONS IN ATTIC: 167(] SG FT. AREA OEBIGN CRITERIA PRESCRIPTIVE AS PER N ¥.S RESIDENTIAL CONSTRUCTION CODE AND 1995 SBC HIGH WIND EDITION. WOOD FRAME CONSTRUCTION MANUAL FRAMING ELEMENTS AS PER FLOOR PLANSr CROSS SECTION AND GENERAL NOTES EXT BALCONIES 6D NAIL NAIL NOTbS JOINT DESCPJPTION QTY. S PACIN~G TOP PLAT]= TO 2 - 16d COMMOP PER FACE NAIL TOP PlaTE FOOT SEE NOTE; 1 TOP pLATE~ AT JDINT~ FACE INT~RSECTIONS 4- I§dCOMMO~ HA. SIDLE NAIL STUD TO 24" FACE 24'-O" f !1 25%5" FOUNDATION PLAN AMENDMENT FOF~ 5TF~UCTURAL ~Ltf='f='ORT ~Od~lN5 F~ESI[DENCE, FIFTI-I 5TF~EET, NEW 5UFFOLK, NY pe.. ~ oF I,~ Au~]uet Iq, 2004 eC~L~I/4" 1'O" JD / MW ? OFFIO~= ' DINING F~OOI'I LIvIN~ $ KITCHEN Fo'"rEt~i % 6'-4" ]O'-O" IOMO" OPEN ~../~ / TO 18,% FLOO:FP-. ~MENDMENT FOR 6T~UCTU~!~L 6UPPO~T ~OG~IN5 RiESIDENCE, FIFTH STREET, NELU SUFFOLK, Pc. '2 OF J,~, &u~ue~ I'T, 2004 sC'~L~l/4" I'O" JP / MN E%&TH I~ATH E~ED~OOM ~ED~OOM ~B.~TF~ '4'-'4I' 4'~4" ,, E~EO:~OOP'I OPEN TO ~ELOU~ 2NE). FLOOR ,4MENOMENT FOF~ 5TRLIOTIJ'~AL 5UPPOF~T ~O~IN5 RESIDENC-E, FIFTN 5TF~EET, NELLI SUFFOLK, P~' 3 oF I3 I"T, 2004 ~CAL~ I/4" = I'0" JO / MN 24'-10" UNFINISI.4ED ONLY ATTIC (.STOF~A~E} 2432 ATT[C, / F~OOF PLAN ,AMENDMENT FOf~ ~Tf~UCTUF~AL ~LtpF~oRT GOGGIN5 F~ESI[])ENCE, FIFTH 5TREET, NEU,I 5L~FFOL~, NY F~, ~' OF I~ I], 2004 eC,~LE[/4,, 1'0" J~ / MN PLUMBING SCHEMATIC INSML~,TION: CEILING; F~30 1ST, FLOOR; RDO dNFINISNED ATTI~ STORX~,~E ~>415TIN~ 2N~, FLOOR \ EXISTINg. 1ST, FLOOR ME,AN t~.OOF NEI~NT: 341-11-I/2" NOTE: ME,AN t~OOF NEI~NT TO liSE NO NI~NEi~ TN,4N 3D' OFF EXISTIN~ ~t~ADE tEXlSTIN~ ESASEMENT 0F O.55 SECTION 9 ~,MENDMENT FOR ~TRUCTURAL SUPf='ORT ~O~IN5 RESIE)ENCE, FIFTN 5TREET, NELL) ~UFFOLK, NY ~' ,~2 o~ J3 I], 2004 ~c¢'L~114': 1'0" J~ I Mb[ WINDOW / DOOR SCHEDULE E'"'OS' RECA 'A OR ' C MEAN ROOF HEI'GHT: 34'-11-1/2" LIVTNG SPACE (EXT. WALLS DOORS / WINDOWS): ATFIC: UNIT AREA UNIT D P NOTES 50 USE DP UPGRADE UNIT 50 USE DP UPGRADE UNTI' ALTERNATIVE FOR OPENING PROTECTION TABLE 1609.1.4 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS FAbTNER SPACING (INCHES) FASTNER PANELSPAN 2FEET<PANEL $'I:EET<PANEL 6FEET<PANEL TYPE < 2 FEET SPAN < 4 FEET SPAN < 6 FEET SPAN < 8 FEET NOOB SCREWS ~OOD SCREWS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE AND TWO- STORY BUILDINGS. PANELS SIIALL BE PREGUT TO COVER GLAZED OPENINGS WITH ATTACFIMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 160§.1 4) WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL FOR WALL OPENING PROTECTION 0F120 MPH 5-SECOIqD WIND GUSTS ( MAXIMUM MEAN ROOF HEIGHT: SHUTTER ASSEMBLY FOR PANEL SPANS: 0 < 4'0 WIDE SPAN 25/52" APA SPAN RATED 48/24 SHEATHING (OVERLAP ARDUND OPENINGS 4") ASSEMB L'r: ATTACHING STRBCTURAL PANEL: FASTEN TO BUILDING #10 (w/ WASHERS) OAI. VII',tlZED OR STAINLESS STEEL WOOD SCREW @ 16" O.C. GRADE PLYWOOD ALTERNAIlVE FASTNER FOR SNUTTER TO BUILDING: #10 TEE NUTS ATTACFIED TO BLDG. w/ t/10 W/ WASHERS) MACI[INE BOLi@ 12" O.C. SHUTTER ASSEMBLY FOR PANEL SPANS: ~- 4' OR WIDER SPAN 23/52" APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD (OVERLAP AROUND OPENINGS 4") 2x4 STRONG-BACKS @ 24" OC ASSEMBLY: 1). PREASSEMBLE PLYWOOD TO 2x4'S.,,#10 (w/ WASFIERS)GALVINIZED OR STAINLESS STEEL WOOD SCREW @~20C 2), ATTACHING STRDCTURAL PANEL. F.A,STEN TO BUILDI #10 (w/ WABHERS),,GALVINIZED Ok STAINLESS ST WOOD SCREW @16 O.C., #10 TEE NIJTS ATTACHED TO BLDG. WA MACHINE BOLT @ 12" O.C. LTIPLE SECTION ASSEMBLY: 1/4" THICK BOLTS @ 2' OC AMENDMENT FO~ 5T~UOTUF~,&,L 5Bf='F~O~T ~.O~IN5 I~ESIDENCtE. FIFTH 5TF~EET, NEUJ 5LJFFOLK, NY Pc, ~ OF l~ ¢&U~Uet I1, 2004 F~ONT ELE',,/,,~TION Af'IENDI'flENT FO~ ~TF~LICTL~F~,~,L ~O~IN5 ~ESIE:,~NCE, FIFTN STREET, NEtJJ 5LIFFOLK, NY 11, 2004 aCAb~ 1/4" = I'O" JP / MN ~E.,&R ELE",/ATION ,,~MENIDMENT FO~B ~T~t]OTUR,~L DUf='PO~T ~O~,IN5 F~ESIDENCE, FIFTI-! 5TF~EET, NEUJ SUFFOLK, NY / l'"fl.4 LEFT ELEV'~TION ,~MENE)MENT FO~ ~T'~IJCTLJF~L 5Lt'pF='O~T GOGGIN5 I~ESIDENCE. FIFTH STREET, NELLI 5L~FFOLK, NY / fflH F~IQNT ELE'v'ATION ,AMENDMENT FOF~ 5TF~L~CTURAL 5UPf='ORT ~O~,~IN5 F~E~IDENGE, FIFTH 5TI~EET, NELU 5UFFOLK, NY WiND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS 4" MAX RIDGE-TO-RAFTER CONNECTION HANDRAIL CONNECTION RAFTER TO PLATE/STUD CONNECTION CEILING JOIST TO BLDG. CONNECTION LEDGER -- RAFTER-TO-LEDGER CONNECTION SPLICED JOISTS OVER HEADER/GIRDER HEADER-TO-POST/STUB CONNECTION RAFTER TO pLATE/STUD CONNECTION FLUSH JOISTS WITH HEADER/GIRDER POST-TO-Gl RD ERIN EAB E R CONNeCTiON POST-TO-DECK CONNECTION POST-TO-GIRDER/HEADER CONNECTION CONC. PIER FOOTING HEADER/GIRDER-TO-POST CONNECTION pOST DECK/PORCH LEDGER CONNECTION DECK POST FTC CONNECTION SPLICED JOISTS OVER HEADER/GIRDER CLIMATIC & GEOGRAPHIC DESIGN CRITERIA DECK AND COVERED PORCH NOTES: NAILING SCHEDULE ROOF SHEATHING: ROOF FRAMING: WALL FRAMING: NAiL ~AIL NOTES DECK FRAMING: ~MEN~MENT FOF~ ~TFBU~TUF~,AL ~UPPOFBT ~O~IN5 F~ESIDENCE. FIFTN 5TF~EET, NEUJ SUFFOLk, Nh' WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS ----ENDWALL ~EINFORCING BAR ROOFING LAPS BASE FLASHING 4 INCHES ~I~E UJ~,LL APPLICATION ANCNOR BOLT CONNECTION ROOF YENTIL~,TION / ~OFFITE~ EA~/E DETAIL \ \ ROOF JAOK~ ~, V'ENT5 DETAIL IEAM AMENDMENT FOF~ STI~UOTUt~,4L ~O~C~INS f~ESI~ENCE. FIFTN STREET, NE~ 5UPFOLK, ~' 12 o~ 13 n, 2004 NOTE5 CONSTRUCTION NOTES: FOUNDATION NOTES: determme intended hmghls of finished floor(s) above lypioal grade. FRAMING NOTES WIND FRAMING NOTES DECK AND COVERED PORCH NOTES: PLUMBING NOTES HVAC SYSTEM NOTES ELECTRICAL NOTES: NAILING SCHEDULE ROOF FRAMING: JOINT DESCRIPTION NAIL NAIL NOTES QTY SPACING RAFTER TO 8' WALL 3-8d COMMON EACH TOE-NAIL TOP PLATE 1 O' WALL' 4 §d COMMOn, RAFTER CEILING JOIST 8'WALL 3-¢d COMMON EACH TOE NAIL TO TOP PLATE D' WALL: 4-8d OOMMOE JOIST CEILING JOIST TO AS PER TABLE 37 EACH FACE WALL FRAMING: NAIL NAIL JOINT DESCRIPTION QTY SPACING NOTES TOP PLATE TO ~ - 16d COMMOb PER FACE NAIL TOP PLATE FOOT SEE NOTE: 1 TOP PLATES AT 1 - lsd COMMOi~ JOINTS FACE INTERSECTIONS EA. SiDE NAIL STUD TO _~ 1Sd COMMOb 24" FACE STUD O C. NAIL 16" C.C. FACE HEADERTO 16d COMMON ALONG EDGES NAiL FLOOR FRAMING: NAIL NAIL JOINT DESCRIPTION QTY SPACING NOTES JOIST TO 4 - 8d COMMON PER TOE 3[LL, TOP PLATE OR GIRDER JOIST NAIL BRIDGING 2 8d COMMON EACH TOE TO JOIST END NAIL ROOF SHEATHING: NAIL NAIL JOINT DESCRIPTION OTY ~PACING STRUCTURALPANEL 8d ASwP~Ec28 CEILING SHEATHING: D NAIL NAIL JOINT ESCRIPTION QTY SPACING GYPSUM 7" O C EDGE WALLBOARD 5d COOLERS 10"O C FIEL WALL SHEATHING: NAIL NAIL FLOOR SHEATHING: STRUCTURAL PANELS 6" 0 C EDGE NOTES; PLAN OONTENT6: CLIMATIC & GEOGRAPHIC DESIGN CRITERIA GROUND WiND SEISMIC FROST WINTER ICESHIELD SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT FLOOD LOAD (MPH) CATEGORY DEPTH TEMP, REQUIRED H~ZARDS ROOF SHEATHING REQUIREMENTI FOR WIND LOADS: NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES SHEATHING LOCATION AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 4T PERIMETER EDGE ZONE 8d COMMON @ S" O.C 8d COMMON ~ 6" O.C SEE NOTES 1,3 INTERIOR ZONE 8d COMMON @ 6" C.C. 8d COMMON @ 12" O C SEE NOTES I ( BOTH FIELDS) 8d COMMON ~ 4" C.C. NOTE 2 FOR PANEL FIELD GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON ~ 4" C.C. SEE NOTES' 1,3 NOTES THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. WALL SHEATHING REQUIREMENTS FOR WIND LOADS: NAIL SPACING NAIL SPACING AT INTERMEDIATE SHEATHING LOCATION AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 4' EDGE ZONE 8d COMMON ~ §" O C 8d COMMON ~ 12" O C NOTES SEE NOTES Ir 3 ( BOTH FIELDS NOTE 2 FOR PANEL FIELD SEE NOTE: 3 NOTES THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCIIEDULE NOTES ONLY 1 ) For weft sheathln§ wllhin 4 feet of Ihe corRerBr the 4 foot edge zone atlachment requirements shall UJ,ALL ,A, MENDMENT FOF~ 5TF~UCTUF~,AL 5UPPOf~T ~O~IN5 ~IESIDENCE. FIFTH 5TR[EET, NEUJ SUFFOLk<-, NY 2004 ~C'*L~l/4" = I'O" JO / f"lH APPROVEO AS NOTED FOLLOWING 1. FOUNDATION ' ~0 ~U~ BE ~MPLETE FOR C.O. ALL coNSTRUCT~N COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTROLD TOWN ZOA SOUTROLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S. DEC OFp~c~E ALL CONSTRUCT1th~',~ ~)4AL~ MEETTHEREQUrPPM.,-~.~ ;*qF rT'H~ CODES OF NEW YOH~, $ l A rE, CERTIFICATION OF NAILING & CONNECTIONS REQUIRED. coMPLY wITH cHAPTER FLOOD DAMAGE pREvENTION soU] HOLD ¥owN coDE. UNOERWRITER8 CERT F CAl~ REQUIRED OCCUPANCY OR USE IS UNLAWFUL ~VlTHOUT CERTIFICATE OF OCCUPANCY DO NOT PROCEED WITH FRAMING UNTIL SURVEY OF FouNDATION LOCATION HAS sEEN APPROVED. 'I [ O '1 I L -~ I J I 12 ,i ooT¼ ,] in. I "5/4-:, -' I LO,, CROSS SECTION END VIEW CROSS SECTION END VIEW WINDOW NOTES BUILDING USE BUILDING AREA BUILDING HEIGHT TYPE OF CONSTRUCTION ~I, GN CRiTERIA LIVE LOAD DEAD LOAD SNOW LOAD SEISMIC ZONE WINDSPEED EXPOSURE CATEGORY Residential - 3 1~,20 Type V Prescriptive Design 40 psf ,' 10 psf 45 psf ground B 120 mph All a'iteria is (les[~ll~t in accordance with the Building Code of New York State &~the American Forest & Paper' Association (AF&PA) Wood Fr~(ne Construct on Manua for One & Two Family Dwelling~ (WCFM-gS} High Wind Addition ~