Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
34768-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34462 Date: 07/12/10 THIS CERTIFIES that the building ALTERATIONS/ADDITION Location of Property: 8095 ALVA/qS LA CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 95 Block 3 Lot 12 Subdivision Filed Map No. __ Lot NO. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated JLrNE 1, 2009 pursuant to which Building Petit NO. 34768-Z dated JIINE 11, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS AND ADDITION, INCLUDING ROOF TOP DECK, TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. · ~ne certificate is issued to EWNEST A BARBARA SCHNEIDER (OWNER) of the aforesaid building. ~UFPOLK COUNTY DEPARTMENTOFHEALTHAPPROVAL N/A ~I~CTRICAL c~KTIFICATE NO. 131778H 07/01/10 PLUMBERS ~i(TIFICATION DA'r~u 07/07/10 ERNEST SCHNEIDER Signature Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application mUSt be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1 Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, indUStrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and ,pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If rCemhcale, atfi!~pancy is denied, the Building Inspector shall state the reasons therefor in writing to the appli ant. ld~O '~0~u ~1 ! C. Fees 1. Certificate of Occupancy- New dwelling $25.00, Additions to dwelling $25.00, A1 ~ ts to0~alltin~ $25.00, }0, BUSinesses $50.00. Swimming pool $25.00, Accessory building $25.00, Additions to accessory buildin~ 2. Certificate of Occupancy on Pm-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5 Temporary Certificate of Occupancy - Residential $15.00. Commercial $I5.00 Date. New Construction: Old or Pm-existing Building: (check one) LocationofProperty: ~O~ 5- /~ V~t~ ~CX.,~A._ C¢~td,.~ House No. Street Owner or Owners of Property: ~:rw'*:~* 3, Hamlet Suffolk County Tax Map No 1000, Section Block Lol Subdivision Filed Map. Permit No. 3 q 7(o ~ ' 7 'Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: Applicant Signature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631 ) 765-1802 Fax (63 l) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLn CERTIFICATION Building Permit No. Owner: ~'rvl e ~f Plumber: (Please print) (Please print) Date: I certify that thc solder used in the water supply system contains less than 2/10 o f 1% lead. Sworn to before me this day of (ii , ,1,',.4 Notary Public, ,20ID County (Plumbers Signature) CONNIE D. BUNCH Notmy Public. Stale of New Yor~ No. 018U$185050 Qualified n Suffolk County Commission Expires Aoril 14, 20 Issue Dnte ?i1~010 Electrical Insp , tion Certificate Electrical Inspection Servlca, Inc. Application Number 375 Dunton Avenue 131778H East Patehogue, New York 11772 (esl) ~e-ee4~ Issued To: Street: Village: Section: Contractor: Ernest Schneider 8095 Alvahs Lane Cuthogue Zip: 11935 Block: Lot: Town: Southold .... ~. L!c. # Was examined and found to be in comprmnce with the National Electrical Code. [] Commercial [] NVDefects [] Pool [] lstFIoor [] Indoor [] Basement I--IHotTub [] Residential [] Det. Garage [] Attic [] 2nd Floor [] Outdoor [] Addition [] Survey Switches Receptacles Fixtures GR Heaters A/C Fans 18 20 12 3 Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwaves 1 20 I 30 Furnace Oil Gas Circulators Smoke Detector Ball Transformer Meter Amps Phase UG/OH Jacuzzi Television CO Detea~r / Bldg. Permit: 29597 Other Equipment 2-Bedroom Addition/5-Combo Smoke IClO Detector/1-20 amp spec. Outlet for Pool HU~ S. Surdi President This certificate must not be altered in any manner. Inspectors may be ~ by their creden6als. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL COMPLETION OF THE WORK AUTHORIZED) FULL PERMIT NO. 34768 Z Date JUNE 11, 2009 Permission is for : hereby granted to: ERNEST SCHNEIDER ~ ALVAHS LA CUTCHOGUE,NY 11935 ADDITIONS & ALTERATIONS TO AN EXISTING DWELLING AS APPLIED FOR at premises located at County Taxx Map No. 473889 Section 095 pursuant to application dated JUNE Building Inspector to expire on DECEMBER 8095 ALVAHS LA CUTCHOGUE Block 0003 Lot No. 012 1, 2009 and approved by the 11, 2010. Fee $ 589.60 ~thorized Signature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ~FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION REMARKS: ROUGH PLBG. INSULATION FINAL FIRE SAFETY INSPECTION FIRE RESISTANT PENETRATION TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [~ FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE I( --I o -- ~ ~ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [~ INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [~)~ FIRE RESISTANT PENETRATION REMARKS: -~'~ ~-- DATE /~'-~}'~ '~ 0 7 INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [~X~ INSULATION [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] FINAL ] FIRE SAFETY INSFECTION ] FIRE RESISTANT PENETRATION REMARKS: INSPECTOR DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST FOUNDATION 2ND FRAMING / STRAPPING FIREPLACE & CHIMNEY FIRE RESISTANT CONSTRUCTION ROUGH PLBG. INSULATION [/~FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PEk,- ,.ATION REMARKS: TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION ~FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION REMARKS: DATE FIELD INspECTIoN REPORT [ DATE ] COMiVIENTS , ~ ~' STATE E~RGY CODE , ~ ) ~DITION~ COUNTS ~- TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 S outholdTown.NorthFork.net Examined ~/[0 , 20 ~0' Approved ~/[[, 20 t'~q Disapproved a/c PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: Expiration /4//, 20 //0 :: / o,.--o'k_.__ [ Building Inspector ~'%'g'-~'-~ APPLICATION FOR BUILDING PERMIT ~'~ This application MU mpletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets)fI ~ sbcea~et Fee according to schedule. area: ~lot and of buildings on premises, relationship to adjoining premises or public streets or c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~ ~qigh~mr-e-oq~applicant or name, if a corporation) (Mailing address of applicantp' State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ,~L-~-~o ¢_<;qF ..~O. t4 ,~_~ _CX.o <" (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which propo~sed work will be done: I~ouse Number Street .~ .- Hamlet County Tax Map No. 1000 Section 1.01 Block 'l Lot/t/, 9 Subdivision Filed Map Noi Lot State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy _~.-.,~/,- x~'~,,,,3 ~,~ J~..~- b. Intended use and occupancy Nature of work (check which applicable): New Building Repair Removal Demolition Estimated Cos~, d/~"e-,~e~, OO~ ,/ - If dwelling, number of dwelling units If garage, number of cars Fee Addition Other Work Alteration (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ,//O ~ Rear at/O t Depth Height ,~Sz' Number of Stories ~ Dimensions of same structure with alterations or additions: Front Depth ..O._Q'-- c~,~ Height ¢2 5t ' Number of Stoi'ies 8. Dimensions of entire new construction: Front / ~ Rear /,-,TL ~ ' Depth Height ~:~' Number of Stories I 9. Size of lot: Front ~1-~5"' ' Rear 260 .Depth '~ ~. ~ c~ 10. DateofPurchase ~/1~/~:5 Name of Former Owner ,EaS ~,~"~/xoor~ 11. Zone or use district in which premises are situated /l-It~. / 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ Rear ,_~,~-.' NO K) 13. Will lot be re-graded? YES__ NO Will excess fill be removed from premises? YES__ 14. Names of Owner of premises~~a2ed~Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. NO ~ 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ~ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. ls this property within 300 feet of a tidal wetland? * YES NO ~,~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES __ NO )~ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) COUNTY O~~S: A,oTo~,o'~-~,,o~o~-'~ being duly sworn, deposes and says that (s)he is the applicant · (Name ofi~dividual signing contract) above named, (S)He is the ~"~, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swo,m to before me this )~-h;--__ day of Q~'.,& tx& 20 ID~ Notary Public Si~mf~e of Applicant Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: $.C.T.M. #: THE FO,U.OWING ACTIONS MAY REQUIRE THE SUBMISSION OF A STORM-WATER~ GRADING; DRAINAGE AND EROSION CONTROL pL~_ Cl=K'l ;tiED BY A DESIGN PROFESSIONAL IN THE STATE OF NBW Item Number: (NOTE: A Check Mark (~) f0t each Question Is Required for a Complete Application) Yes N._.~o 1 2 3 4 5 6 7 8 9 Will this Project Retain All Storm-Watar Run-Off Ganemtad by a Two (2"} Inch Rainfall on Site? (This item will include all run-off created by site ctearing end/er construction activities as well as all Site Improvements and the penmanent erea~on of Impantlous surfaces.) Does the Site Plan and/or San/ey Show Ail Prupoesd Drainage S~ructures Indicating Size & Location? This Item shall include all Proposed Grade Changes and Slopes Controlling Surface Waten~lowl Will this Project Require any Land Filling, Grading or Excavation where thera is a change to the Natural Existing Grade Involving more than 200 Cubic Yards of Matedct within any Parcel? Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000) Square Feet of Ground Surface? Is Ihere a Natural Water Course Running through the Site? Is this Protect within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach? Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen [15~ feel of Vertical Rise to One Hundred (100') of Horizontal Distance? Will Driveways, Parking Areas or other Impervious Surfaces be Sloped to Direct Storm-Water Run-Off into and/or in the direction of a Town right-of-way? Will this Project Require the Placement of Material. Removal of Vegetation and/or the Construction of any Item Within (he Town Right-of-Way or Road Shoulder Area? (This item will NOT include the Installation of Driveway Aprons.) Will this Project Require Site Preparation within the One Hundred (1001 Year Floodplain of any Watercourse? NOTE: If Any Answer to Questions One through Nine is Answered with a Check Ma~ in the Box, a Storm-Water, Grading, Drainage & Erosion Control Plan Is Required and Must be Submitted for Review Prior to Issuance of Any Building Permit( EXEMPTION: Yes No Does this project meet the minimum standards for class flcaflon as an Agricultural Project? Note: If You Answered Yes to this Question, a Storm-Water, Grading, Drainage & Erosion Control Plan is NOT Requiredl ^ rEOF NEW¥O , hA cot N ............ ss I, Aa~.-'.'~3~....'.'.~.. ~...~ .,~..Z~..~.~...~... ........................ being duly sworn, de~s~ ~d says fl]at hqsl~d~l~ ~ for Penni~ ~at (Name of indiddu~?gning D~nt} N er. Con~or Agen~ Com~ e 0~. · c. C0mmmsm Ex0ir~ Aofi 14. ~J~ O~er ancot mpr~en~Uve of~e Owner of O~er's, ~d is duly auto.ed to perform or have performed ~e s~d work ~d to m~e ~d file ~is application; ~at fll sa~men~ con.ned in ~is application are ~e to ~e best ofh~ ~owled~ ~d ~lief; ~d · at ~e work will be performed in ~e m~ner set fo~ in ~e application filed herewi&. Sworn to before me this: ................. ................ day ..................... © ' _ ............... FORM - 06/07 '1'o~ n 1 lall Annt'x ,5 I~q75 Main Road Sotdhold, NY 11971 Tclcphonc ((;31) 765-1802 l:ax (6;11) 765-!1,502 1',1 !ILl)IN(; 1)I';PARTMENT TOWN OF SOUTHOLD July 2, 2010 Ernest Schneider 7645 Alvahs Lane Cutchogue, NY 11935 TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occupancy: __ Final Health Department approval. '~ Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) __ Application of Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of $25.00. __ Trustees Certificate of Compliance. __ Final Planning Board approval. __ Final Fire Inspection from Fire Marshal. __ Final Inspection from the Building Dept. __ Final Landmark Preservation approval. Building Permit: 34768-Z additions/alterations TOWN OF SOUTHOLD PROPERTY RECORD CARD O--~NER '- - STREET ~Oq.~ VILLAGE DIST. SUB LOT ~.~ REMARKS / ~ TYPE OF BLD. __ PR?P' CLASSz ~ ~ LAND IMP. TOTAL DATE FRONTAGE ~N WATE~ ~ ............ .... TILLABLE {'~'~'O ~ ~0 FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT COLOR TRIM ?//9/ I~/.~ M. Bldg. / ~'-~ ~'O ('~ O t3 Z/, TS"' ~.%,' -~c~ Foundation ~ Bath I/~4 .= c a ~/~¢ Dinette Exlensi°n / ~ X/-/O c ~, C, O ,~. Z~' / ? ~" O Basement SLABC"^WL Floors ~,,~ R ~ Kit' Extension Ext. W~lls ~ ~ ~ [ Interior Finish L.R. Extension Fire Place ~O Heat O't ~ D.R. Patio Woodstove BR. Porch Dormer Fin. B. Deck Attic Breezeway Rooms 1st Floor Garage ~ ~ ~ ~ Driveway Rooms 2nd Floor o.~.. Pool REScheck Software Version 4.2.1 Compliance Certificate Project Title: PROPROSED 1ST FLOOR ADDITION TO SCHNEIDER RES., JOB/f-09-012 Energy Code: 2007 New York Energy Conservation Construction Coda Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Arco Percentage: 19% Heating Degree Days: 5750 Consbuc§on Site: Owner/Agent: Designer/Contractor: Robed J Gruber,RA 476 Expmesway DR. SO. Medford. NY 11763 631-654-4949 RJGRUBERRA~__.AOL.COM .____;_1:_.:;: ....... .~.~..H~1 Compliance: 1.2% Better Than Code Maximum UA: 83 Your UA: 62 Ceiling I: Flat Ceiliog or Scissor Truss Wall 1: Wood Frame, 16' o.c. Window 1: Wood Frame:Double Pane with Low-E Door 1: Glass FIcor 1: All-Wood Joist/Trues:Over Unconditioned Space 357 38.0 0.0 11 432 15.0 0.0 27 42 0.320 13 40 0.350 14 357 19.0 0.0 17 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application, The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed t~is pa!!~e~ they are attesting that to the best of his/her knowledge, belic~, and professional judgment, such plans or specifications are in com~n~e~vith this Code. Name Title S~gn D~--~"~ REScheck Software Version 4.2.1 Inspection Checklist Ceilings: [-I Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: Above-Grade Walls: ['"1 Wall 1: Wood Frame, 16' o.c., R-15.0 cavity insulation Comments: Windows: ['-I Window 1: Wood Frame:Double Pane with Low~E, U~factor: 0.320 For windows without labeled U-tactors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No Ooor~: Door 1: Glass, U-factor: 0,350 Comments: Floors: Floor 1: All-Wood JoistiTruss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Air Leakage: r-I Joints, peneb'ations, and ali other such openings in the building envelope that ara sources of air leakage are sealed. [] Recessed lights are 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearenca from combustible materials. If non-lC rated, fixtures are installed with a 3' clearance from insulation. Vapor Retarder: I-I Installed on the warm-in-winter side of ali non-vented fl'amed ceilings, walls, and floors. Materials identification: F'I Matariats and equipment are installed in accordence with the manufacturer's installation instructions. [] Materials and equipment ara identified so that compliance can be determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. [] Insulation R-values and glazing U-factors are clearly marl(ed on the building plans or specifications. [] Insulation is instatied according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct insulation: [] Supply ducts in unconditioned attics or outside the building are insulated to at least R-8. [] Return ducts in unconditioned attics or outside the building are insulated to at least R-4. r-I Supply ducts in uncondiflened spaces are insulated to at least R-8. [] Retam ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [] Ail joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), masUc-plus.embedded-fabric, or tapes. Tabes and mastics are rated UL 181A or UL 181B, Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [] The HVAC system provides a means for balancing air and water systems. Temperature Controls: [] Ea'ch dwelling unit has at least one thermostat capable of automatically adjusting the space tampemture set point of the largest zone. Electric Systems: [] Separate electric meters exist for each dwelling unit. Fireplaces: r-I Fireplaces are installed with tight fitting non-combustible fireplace doors. I~ Firep~aces have a s~urce ~f c~mbus~n air~ as required by the Rreplace c~ns~ruc~n pr~vi`~J~ns ~f ~he Bui~ding C~de ~f New Y~k State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [] Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat hap or is part of a circulafing system. [] Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: [] Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depietable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: F3 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Ta~ bl~inimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runoute Circulating Mains and Runouts Heated Water Tempemtere (°F) Up to 1' Up to 1.25" 1.5' to 2.0' Over 2' 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp, Insulation Thickness In Inches by Pipe Sizes Piping System Types Range(OF) 2,' Runouts 1' and Less 1.25" to 2.0' 2.5" to 4' Heating Systems Low Pressure/Temparature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Coolteg Systems Chilled Water. Refrigerant and 40-55 0.5 0.5 0.75 t .0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (BuJldlog Department Use Only) ~2, / I °~ ~ ro N'L~' ~vo c~ ~ S 33' 27 E I I I I t ~699.87' REScheck Software Version 4.2.1 Compliance Certificate Project Title: PROPROSED 1ST FLOOR ADDITION TO SCHNEIDER RES., JOB~09-012 Energy Code: 2007 New York Energy Conservation Construction Code Location: Suffolk County, New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 19% Heating Degree Days: 5750 ConstmcUon Site: Owner/Agent: Designer/Contractor: Robe~l J Gmher, RA 476 Expressway DR. SO. Medford,, NY 11763 631-654-4949 RJGRUBERRA~OL.COM Compliance: t .2% Better Than Code Maximum UA: 83 Your UA: 82 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Wood Frame;Double Pane with Low-E Door 1: Glass Floor 1: Ali-Wood JoistJTruss:Over Unce~difioned Space 357 38.0 0.0 11 432 15.0 0.0 27 42 0.320 13 40 0.350 14 357 19.0 0.0 17 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meat the 2007 New York Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, aed professional judgment, such plans or specifications am in com~!s Code. ~ Signature/ D~e REScheck Software Version 4.2.1 Inspection Checklist Ceilings: Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: Above-Grade Wells: r-I Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation Cerements: Windows: Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labelod U-factors, descdbe features: #Panes Frame Type _ Thermal Break? Comments: Yes __ No Doors: I-Z Door 1; Glass, U-factor: 0.350 Cemments: Floors: I-I Floor 1: Ail-Wood Joist/Truss:Over Unconditioned Sp~tea, R-t 9.0 cavity insulation Comments: Air Leakage: [] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. Recessed lights are 1) Type lC rated, or 2) installed inside an aoprup~iate air-tight assembly with a 0.5' clearanca from combustible materials. If non-lC rated, fixtures are tnstaltad with a 3" clearance from insulation. Vapor Retarder: r-i Installed on the warm-in-winter side of alt non-vented framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment are installed in accordance with the manufacturer's installation instructions. [] Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R-values and glazing U-faCtors are clearly marked on the building plans or specifications. [] Insulation is installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building are insulated to at least R-8. [] Return ducts in unconditioned attics or outside the building are insulated to at least R-4. Supply ducts in unconditioned specas are insulated to at least R-8. [] Retum ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams, and connections are securely fastened with walds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [] The HVAC system provides a means for balancing air and water systems. Temperatur~ Controls: i-I Each dwelling unit has at least one thermostat capable of automatically adjusting lhe space temperature set point of the largest zone, Electric Systems: r-I Separate elec~c meters exist f~r each dwelling unit. Fireplaces: r-i Fireplaces ara installed with tight fitting non-combustible fireplace doors. [] Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Bu#ding Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [] Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [] Circulating hot water pipes are insulated to the levels in Table 1, Circulating Hot Water Systems: [] Circulating hot water pipes ara insulated to the levels in Table 1. Swimming Pools: [-t All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depleteble sources, Pool pumps have a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5' to 2.0' Over 2" Temperature (°Fi 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Range(°F) Insulation Thickness In Inches by Pipe Sizes 2' Runouts 1" and Less 1.25' to 2.0' 2.5" to 4' Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1 ~0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) GENERAL NOTES: REFERENCE STANDARD FOR DESIGN OF STRUCTURE CLIMATIC & GEOGRAPHICAL DESIGN CRITERIA - NYS CODE TABLE R301.2(1) HEADER ANCHORAGE DETAIL RAFTER TO RIDGE DETAIL ¢ n'~T/~J- · ia" ON O=N'm~. ) , , , ..... , ,, ,, NAILING REQUIMENTS FOR ASPHALT TABLE 3.4 RIDGE TENSION ST~P CONNECTION REQUIREMENTS GIRDER CONNECTION TO FLOOR JOIST BRIDGING ~ ~ Table, 3.[, NalIIn~ Schedule ( 2001 AF & PA ) ~CM, ROOF SHINGLES ~~~ ,~-~.~ .~.~.~ (~ PIPE COLUMN ¢~T~L · ~CH COL~ , , , ,,, ,,, ' STUD TO BAND JOIST TO STUD DETAIL Si~ki~gto~il]or?op~lal.~e,-nailed) , ' 3-1~ 4-1~d e,ehbloc~ ~. ,e 2 = ~ · I1' ==" =~ "= OF S~P I~" C.C. ~- . . STUD TO SILL PLATE DETAIL ~ INSTALL · la" ON CEN~ ) s~.~, ' ~ ~0a ~mo~ ~,u~ ,~ ~ ~,~. CANTILEVER OVER FOUNDATI'ON (IN~TALL · la" ' INST~TION, .ON~TI~ A ~ ~/ 5-¢d COHHON J 51DE AIR 5~N~TH AT 25 t" or,I,,, 8d , ]0d 6" ,,g./I~" ~.]a )CAP ~IN~ ~ ~ ~I~I~TANT ~A ~F 2" BLOCK FU~IN~~'1~~ CANTI LEVER OVER 1 st FLOOR (l~TALL Diagona[9oardShc~g ~ V~ LINI~ ~L BE TABLE 3.7 - RAFTER / CEILING JOIST HEEL JOINT CONNECTION L size ~OT ~TlO, ~ A ~ I/=" FO~ INSULATION - 2-¢d COHHON - INSULATION O~R OUT ~f cO~Yl~ ~l~ ~ ~ I~lO ~ ~,= ~ ~ ~ · · ~= ~ ~ ~ I/=" C~X PLYHOO~ 5HEATHIN~ ~ P ~ a ~C FIGURE 2.2a -~PICAL ~TE~L F~ WALL SHEATHING NOTE: TABLE R905.2.8.2 ~= ~ ~ s ~ ~ ~= =~4 ~ ED~E~ ~ I=" O.~. IN THE FIELD. ~ ~I ~lm~son ~o,~-Tle~lm eon ~on -Tie ~/~/~' L~A~D IH Al~-~ D~I5 ~10~ ~g HA~ WIND-BORNE DEBRIS PROTECTION PAI~ ~ ~o ~/~ ~ '~ ~ -- -- YORK STAFE. NOT ,,ESPONSIB.E FOR UNOEI e~EP O~NIN~ ~C~ ~H nl~-~ ~EBRIS FASTENING SCHEDULE FOR WOOD 4~ .0~ ~ ~IL~IN~ ~L BE ~1~ ~ A PA~TI~L~ Efl~ CEIG~ A~ S~DL~. A tRICOT O~ e/4 4.oo 5E 5IHPSON" ~ DESIGN OR CONSTRUCTION E {RORS. ' ~ OUJRED .- ~ ~B, ~ 09-¢12 IO'-8" C, LOSET ,, /. 51TTIN6 0'-4" rS PORN HALK-IN % OLO~T BATH AREA =RL'r' OM ~B J ,/!U ............................... I '-'t HA~HE~/DRYER ~ /. 2NI2 FLOOR PLAN EXISTINE~ A~DITION PARTITION SCHEDULE NEW 2X6 STUD WALL @16" 0. C. NEW 2X4 STUD WALL © 16" 0,C. EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED ~XI.~TIN~ A~DITION f- (EXT',~) 50 68 m~'e) 50 68 ~o~ TO / ~I~O~ TO ~HAIN SLIDIN( DOOR ~AIN SLIDIN( DOOR KITCHEN =: -, (N~) -- FOrMErLY ~ FO~ME~Y (ND~ LIVIN~ ROOM CL. DEDROOH ~1 ~ ~2 DEDRO0~ ¢ - 40'-O" ~'-O"8 '-O EXISTIN~ EXT'C~ EXISTIN¢ CONC,. II PND HALL 11'-4" ~-j u~.~ ~ 2"XlO" P.J. ~ I%," 0.6. F , . . I ~ I mXT'O) ~ (NE~) /EXleTIN¢ __ /FOUNDATION ~ ~ALL EXIDTIN¢ C, ONC,.? PND HALL ADDITION MASTE~ BEDROOM - (..ONT. ERE FORMEf~LY' ALUM. DETAIL BEDROOM #4 FLAEHIN'~ (NEY9 LIVIN¢ ~OOM PORMEP, L"r' BEDROOM OONC. PIER ~" CONO --ND YIALL ~/~" DIA. ~=~OX"¢' C, OATED 14" LON~, H/ T' MIN. SPAC, ED I~" V~ERTIOALL¥, FILL HITH HIE~H ~TREN~TH I=POX¥ MORTAR, mXI~TIN~ AD.~ITION -,1(" HOLD DOHN LOC,ATION~ A5 PE~ HFC. H 2OOI EDITION sECTION 3.4 EXTERIOR sHEAR HALL TYPE II (TYP) FOUNi2ATION PLAN EXT'~ F.J. @ I&" O.G. (EXISTINg) BASEMENT 5/4" AG~ PIOO~212EGKIN¢ AGd~ SLEEPEP-. TAFEI~ED ON RtJ~BEP. MEME,~ANE faOOFIN® ON I/2" GPX Ph"r'~. 5HEATHIN~ HIgH RAILIN¢ HUt~.t~.I G AND GLIF~ INSUL. 2XIO G.J. q-I/2" TO '-MI2" (NE~ 9 BEDROONf 'E,/4" T. ~ ~. E:~JB 2"XlO" P. J. ¢ IS" O.G. B/4" ACd~ I,~OO12 ~2EC~IN~ AG~2 SLEEPER TAPEF~ED ON P-I,]BBEP. MEPIE~f=~ANE ROOFIN~ ON I/~" GDX PLT'Y~DL ~HEATHIN~ 2XIO C,,.J. TAPERED -- q-I/2" TO q-I/9" HUt~RIC, ANt~ CLIP5- @ EA. RAFTER D,&" HIgH RAILIN~ DRAIN TRIM BOARD HUP, RIOANE ¢TRAP EA. RAFTER -- ~/ENTED SOFFIT T BASEMENT ~ P. CON(,,. FOUNDATION ~ALL ON I~,"xS" DEEP P'. GONG,. FTC. ETAIL -I 5OALE~ I" = I'-O" EXT' / P. GONC,. sLAB EXISTIN~ ADDITION FLOOR PLAN EXISTIN~ I/4" · I'-0" ADOITION SECTION A - A EGALB, I/4" = I'-O" --4" POURED GONG, SLAB, I.',V ~," X ,~" IO/IO Y41~F ADDITION FOR ~ ^Lv,.~ ~,.~ ERNEST SCHNEIDER SC^L[: AS NOTED ~pEOV[D BY: DRAII~N BY: JT DA~ 01-20-0g Robert J. Gruber- Architect 476 Expresswa}, Drive S0. Medf0rd, N.Y. 11763 (631) 654-4949,.,,~.~ .u..~.: 1ST & 2ND FLOOR PLAN 1~,2 OF EXI.~TIN~ ADDITION EXISTIN~ VINYL TO FR.~I'4AIN EXT'G AGPHALT SHINGLES L HIGH I;~NILING NEI, N VINYL SIDING TO MAT~.,H EXICTING ] XT'~ f~.~. FOUNDATION ~ 12"XI2" I ~ OON~. ~1~ ~" ~.~. FOUNDATION FP.,ONT I=LE%/ATI ON EXICTIN® ADDITION I/4" = I'-0" EXT'G ASPHALT TO NEF'I ~'" HICH ~;-.AIL ~IDIN~ TO I"fATCT, H EXICTIN~ VINYL ~IDIN~ FOUNDATION / _1 ~.I®HT ~I]::2F: F:L]~",/ATION I/4" · I'-O" 4"X4"AO~ POeT ADDITION EXIBTIN~ SC" HIGH ~,AILIN(D ASt~HALT SHINGLED REMAIN EXISTING VINYl. 5IglNG rD REI'4AIN BUILDING~ 4" H. TRAP NEW WASHER BIDET 2nd FLOOR EXT'O NEW LAV. LAV, EXTO 12"XI2 VINYL SIDING ADDITION EXI5TIN®t~EA~ t~LEVATI ON PLUMBING RISER (SANITARY WASTE) !?:'' ADDITION FOR .. ,., ,,,.,,^,, ,.,~ ERNEST SCHNEIDER ~u,o.o~.~ ..~ SCAL[~ AS NOTED APPROVED el: DRA'~ s~ Jf DAI~= 01--20--09 R£~4S[D BY: · ~a~* d.+ 476 Expresswo~ Drive So. Medford, N.Y. 11763 (630 654-4949 ELEVATIONS 5 OF 5 ~": ~ 0~-012