Loading...
HomeMy WebLinkAbout34459-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34438 Date: 07/08/10 THIS CERTIFIES that the building ADDITIONS-ALTERATIONS Location of P~)ez~cy: 10105 OREGON RD (HOUSE NO.) (STREET) (HAMLET) Co%u~t¥ Tax Map No. 473889 Section 83 Block 2 I~Dt 19.4 Subdivision FiledMap No. Lot No. CUTCHOGUE conforms substantially to the Application for Building Permit heretofore filed in this office dated FEBRUARY 25, 2009 pursuant to which Building Permit NO. 34459-Z dated FEBRUARY 25, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS AND ADDITIONS, INCLUDING REAR DECK AND COVERED FRONT PORCH, TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to DONNA M WALTERS & RACHEL BEREZNY ( OWNER ) of the aforesaid building. SUF~OLKCO~NTYDEPARTMENTOFHEALTHAPPROlrAL N/A EL~t-rKICAL CERTIFICATE NO. 12656 04/02/10 CERTIFICATION DATED 11/25/09 TEODORU PLUMBING INC Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPAb This application must be filled in by typewriter or ink and submitted to the Building Det For new building or new use: 1. JUL - 6 2010 .. B.I. DG~DEPT. Final survey of property with aocurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage.disposal (S.9 form). Approval of alectfical in.~tallation fi~om Board of Fire Underwriters. Sworn statement from plumber certifying that the ~older used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a Certificate of Code Compliance from architect or engineer respousible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. F~rea~s~ngbui~dings(pri~rt~Apri~9~9~7)n~n~¢~nf~rmingus~rbui~dingsand"pr~-existing~~anduses: 1. Aocurate survey of property showing all property lines, streets, building and unusual naturat or topographic features. 2. A proper!y completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25 00 ~titions to dwelling $25-~., Alterations to dwelling $25 00, Swimmin · ' '~'" ' ~ - ' g pool $25.00, Aecessory building $25.00, ~aa~t~ons to accessory building $25.00, Businesses $50.00. 2. Certificate of Oecupancyon Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential S 15.00, Commercial $15.00 New Construction: Location of Property: Date. xJ (.3Q(~ ~-'~, ~l c.~ House No. Old or Pre-existing Building: Street ,/ (check one) '"Hamlet Owner or Owners of Property: · Suffolk County Tax Map No 1000, Section su sio. Block 000 ~ Lot Pcaiuit No. '~ L~ ~6~ - ~ Date of Permit. Dept. Approwl: Filed Map. , Lot: Underwriters ~pm~I:, ~/A Planning Board Approval: '/~[ Request for: Temporary Certificate Fee Submitted: S Final Certificate: ~(check one) Applicant Signature 11-0B-09;17:10 ; 97494325 # 11 Town 14~1 Amex P.O. B~ 1179 · ~mtha~. lqm~ Yodl: 11971-09~9 BUILDING OBPARTMI~lqT TOWN Olv SOUTHOLD CRRTIFICATION prat) I cet'ti~ that thc sokler used in the wat~ supply systgm oontaim l~ss than 2/i0 of 1% l~ad. Swam to b~f~rc mc 40 Nottingham Drive, Middle Island, NY 11953 Telephone: 831 495 8136 · Fax: 631 980 6455 · E-Mail: SBEIGS~gmail.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Rough In Inspection Date: Application No.: Express Electric Certificate No.: 12656 Final [nspection Date: Apr 02, 2010 12656 Building Permit No.: 34459Z County Tax Map No.: This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant named above, located at the premise of and not after the final inspection date above: Owner: Rachel Berezny Donna Walters Site Location: 10105 Oregon Rd, Cutchogue, NY 11935 Owner's Address (if different): Residential Indoor Basement Service Shed Commercial Outdoor First Floor ' Pool Hottub New Renovation ;-~; Second Floor ~ Attic i Garage Addition i~ i Survey Other: INVENTORY Single Phase Heat Dupfax Recpt 36 Ceiling Fixture 4 HID Fixtures Three Phase Hot Water GFCI Recpt 4 Wall Fixfom 4 Smoke 3 Main Panel AC Cond Single Recpt RecesSed Fixture 21 CO Detect 1 Sub Panel AC Blower Range Recpt FIoureseent Smoke CO Combo Transformer Appliances O~/er Recpt Emergency Time C~ck Disconnect Switches 34 Twist Lock Exit Fixtures Pumps GFCl Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan 2 Other Equipment: 4 paddle fans, 1 widpool bath, some minor changes to first floor while cons{rucfin second floor addition The electrical work and/or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements and this office. Applicant: Express Electric Inspected By: Roger Richert License No.: 3653-ME Date Of Certificate: Apr 08,2010 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Nall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34459 Z Date FEBRUARY 25, 2009 Permission is hereby granted to: DONNA WALTERS PO BOX 347 CUTCHOGUE,NY 11935 for : ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.THIS REPLACES BP# 31754. at premises located at County Tax Map No. 473889 Section 083 pursuant to application dated FEBRUARY Building Inspector to expire on AUGUST 10105 OREGON RD CUTCHOGUE Block 0002 Lot No. 019.004 25, 2009 and approved by the 25, 2010. Fee $ 545.70 Auth--o~rized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31754 Z Date JAi~UARY 25, 2006 Permission is hereby granted to: DONNA WALTERS PO BOX 347 CUTCHOGUE,NY 11935 for : ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 10105 OREGON RD County Tax Map No. 473889 Section 083 Block pursuant to application dated J~297JARY Building Inspector to expire on JULY Fee $ 545.70 CUTCHOGUE 0002 Lot No. 019.004 4, 2006 and approved by the 25, 2007. ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ [ ] FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [~ROUGH PLBG. ] INSULATION ] FINAL ] FIRE SAFETY INSPECTION REMARKS: INSPECTOR DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [~OUNDATION 1ST [ [ ] FOUNDATION 2ND [ [ ] FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] ROUGH PLBG. ] INSULATION ] FINAL ] FIRE SAFETY INSPECTION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] INSULATION [/~ FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-t802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND ~/~INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESL~TANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PE#ETI~TION REMARKS: INSPECTOR ~ ~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION REMARKS: [ ] ROUGH PLBG. [ ] INSULATION ,~ FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]ROUGH PLBG. [ ] FOUNDATION 2ND [ ]INSULATION [ ] FRAMING/STRAPPING ~)~FINAL ~ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] RRE RESISTANT PENETRATION REMARKS: DATE ~ -- I~--/o · ITECNOLOG!E__S April 10, 2006 '1 Town of Southold Building Department Main Rd. Southold, NY 11971 Re: Darryl Berezny Oregon Rd. Southold, N.Y. 11971 S.C.T.M # 1000-83-2-19.4 To Whom It May Concern: Mr. Frank Notaro inspected and certifies the following: 1. Single 1 a/4" x 11 7/8" LVL ridge beam was used in place of the double 1 3/4" x 11 7/8" as specified on the construction documents, this did not cause any negative effect on the structure of the ridges. 2. Strapping inspection of the addition was made on April 10, 2006. All strapping was applied as per specifications on the construction documents prepared by Architecnotogies. All strapping meets or exceeds the requirement of New York State Building Code. If you have any additional questions please feel free to call our office at 631-298-1129. June 27, 2006 Southold Town Building Dept. P.O. Box 1179 Southold, N.Y. 11971 Re: Mr. Darrell Berezny 10105 Oregon Rd. Cutchogue, N.Y. B.P. # 31754 To Whom It May Concern: According to our energy calculations using R-19 in exterior walls of the addition meets or exceeds the energy requirements of New York state energy code. If you have any additional questions please feel free to call our office at 631-298-1129. FOUNDATION (1ST) PL~B~G ~SULATION PER N. Y. STATE ENERG~ CODE TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 ..~ www. northfork.net/S~outhold/ PERMIT NO. ~ Check a 7 / ' ' Examined ~p,~20 Contact: p rov a r& °X r Disapproved ~c 7 / ~/ )~ -- Expiration 2~0~ ~ /~ Phone: "' 3~ ~ ~ ~ APPLICATION FOR BUILD~G PE~IT -'~ ~ Date ~" (' ~ ' ~ ~- .... J INSTRUCTIONS BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey ,200~ a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 mouths after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as heroin described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ,.~ (Signature of a'~icant or name, if a corporation) (IV~ailing address of applicant) - State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As' on the fax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders LicenseNo. Plumbers License No. Electricians LicenseNo. Other Trade's License No. Location of land on which proposed work will be done: I 0 I0,'~ DRg~,E)Lb ~:D. House Number Street County Tax Map No. 1000 Section Subdivision (Name) Hamlet Block o~, "~;' Lot /t~.~ . .: Filed Map No. ' ' Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~c~t-~6tE ~-~-~d!~. b. Intended use and occupancy ~.~D.i ~-~C~t ~ ?fl-M~t-/~ Nature of work (check which applicable): New Building. Repair Removal Demolition / Addition x: Alteration Other Work Estimated Cost ~0 I CC3~'~ Fee If dwelling, number of dwelling units If garage, number of cars (Description) (To be paid on filing this application) Number of dwelling units on each floor If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front "}~' I0" Rear '~ c~' I 0 "' Height I~ */- Number of Stories I ~ Dimensions of same structure with alterations or additions: Front '7 ~¢' I O" Depth3/~'q~l~a~- I~'Z-'~. Height oql~' 10"*/- Numberof Stories DepthS. Rear 8. Dimensions of entire new construction: Front Rear Height Number of Stories 9. Size oflot: Front [~1/./.t~' Rear I~Li. /~' Depth Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated ~-~ ' 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO ~ 13. Will lot be re-graded? YES NO Y' Will excess fill be removed from premises? YES NO ~ __ ~O~o~ O e-~Go~-~ 174D..~O~o~ O e-~Go~-~ . 14. Names of Owner of premises331t~,gli,~d2t/~.-j[~4~'~Address - .hone No. NmeofArchitectVe¢~ Dor3~- ~_ t' ' 'Address ,0, o PhoneNo~ Nme of Con,actor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES __NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES__ NO ~' * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF~ Dcc~ ~...~ ~3~-h ,'T'~CrY _,"~2¥~,h~/~ being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the ~,ca~ ~ ' (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this__ _, ~ day of ~-~[ jql ~(~ ~L~ 2 0~{~19 RENEE O. CUNNINGHAM N~ Publl~, 8tare of New Y~ No. 01CU6132059 Quailed In S~lk Cou~ ~ ~mmlssion ~pires Aug. 22, 20~ ' ~.~' Signature of Applicant ITECNOLOGIES ~ l~405ld~inlts~d,b~ilck, lqe~Yo~k 11952 ~ 631.2~.1129 t~ 631.29~1128 January 23, 2006 Town of Southold Building Department Re: Mr. Darrell Berezny 10105 Oregon Rd. Cutchogue, N.Y. To Whom It May Concern: This letter is to certify the following: Cesspool certification was performed by: Manny's Cesspool Service, Inc. on December 15, 2005 concluding the following: a. Septic tank size -- 1,000 gal. and is in good condition. b. 2 cesspools were located consisting of 8 by 4 rings at 12' depth in good condition. If you have any additional questions please feel free to call our office at 631-298-1129. PRODUCT 81 ~) PRIN~D IN U S A DANNY'S CESSPOOL SERVICE, INC. A Div. ~ Daniel J. Wa~s Cesspool Se~ice 229 HoAonAvenue RIVERHEAD, NEW YORK 11901 (631) 727-6325 [] ~ [] ~HARGE [] MERCHANDISE RETURNED [] C.O,D. ~ e~ O~ Q~. DESCRIPTION )RICE AMOUNT ~ C~p~l Pureed (Gals. ) 2 Chemical ~ Aeration to open drainage 5 ~vers ', 6 ~r 7 Ce~! installation ', THANK YOU · ITECNOLOGIES Januaw 04,2006 Town of Southold Building Department Main Rd. Southold, NY 11971 Re: Darryl Berezny Oregon Rd. Southold, N.Y. 11971 S.C.T.M Cf 1000-83-2-19.4 To Whom It May Concern: Per requirements by New York State Residential Construction Code we certify that the design criteria is done per prescriptive design. All of the load calculations and structural plans comply with all of New York Construction Code based on (AF&PA) for One-Family Dwelling to the best of our knowledge. If you have any additional questions please feel free to call our office at 631-298-1129. Cc: Berezny File ITECNOLOGIES Januaw 5,2006 Town of Southold Building Department Main Rd. Southold, NY 11971 Re; Darryl Berezny Oregon Rd. Southold, N.Y. 11971 S.C.T.M Cf 1000-83-2-19.4 To Whom It May Concern: The following modifications have been made to previously submitted set of construction documents for review: 1. The second floor A.2 addition does not propose for a new kitchen area. Client will apply for a two family dwelling in the future. 2. Energy calculation sheet A.5 has been modified to reflect changes. If you have any additional questions please feel free to call our office at 631-298-1129. Sincerely Yours, Frank Notaro R.A. Permit # Permit Date REScheck Software Version 3.7 Release lb Compliance Certificate Project Title: Berezny Residence Report Date: 01104/06 Energy Code: 2000 IECC Locatlan: Cutchogue, New York Construction Type: Single Family Glazing Ama Percentage: 10% Heating Degree Days: 5572 Construction Site: Oregon Rd. Cutchogue, NY 11935 Owner/Agent: Darryl Berezny Oregon Rd. Cutchogue, NY 11935 Designer/Contractor: Frank Notaro, R.A. Architecnologies 13405 P.O. Box 93 Mathtuck, NY 11952 (631) 298-1129 Architacnologlas@ya hoo.com ii11 Window 1: Vin Window 2: Vin Window 3: Vin Window 4: Vin Window 5: Vin Window 6: Vin Window 7: Vin Window 8: Vin Window 9: Vin Door 1: Solid: Door 2: Glass: Ceiling 1: Flat Ceiling or Scissor Truss: Wall 1: Mason~j Block wi~ Empty Cells:Extedor Insulation: Wall 2: Wood Frame, 16" o.c.: ~1 Frame:Double Pane with Low-E: ,I Frame:Double Pane with Low-E: ~1 Frame:Double Pane with Low-E: ,I Frame:Doubla Pane with Low-E: ~1 Frame:Double Pane wi~ Low-E: ri Frame:Double Pane with Low-E: ~1 Frame:Double Pane with Low-E: ,I Frame:Double Paoe with Low-E: ,I Frame:Double Pane with Low-E: Wall 3: Wood Frame, 16" o.c.: 1825 38.0 4.5 47 1256 9.2 4.5 92 1652 21.0 4.5 66 30 0.350 11 30 0.350 11 30 0.350 11 12 0.350 4 53 0.350 19 11 0.350 4 23 0.350 8 10 0.350 4 8 0.350 3 21 0.350 7 39 0.350 14 1583 21.0 4.5 66 8 0.350 3 8 0.350 3 18 0.350 6 17 0.350 6 18 0.350 6 23 0.350 8 23 0.350 8 6 0.350 2 6 0.350 2 6 0.350 2 30 0.350 11 9 0.350 3 9 0.350 3 24 _ 0.350 8 Page lofT Window 10: Vinyl Frame:Double Pane with Low-E: Window 11: Vinyl Frame:Double Pane with Low-E: Window 12: Vinyl Frame:Doubla Pane with Low-E: Window 13: Vinyl Frame:Double Pane with Low-E: Window 14: Vinyl Emme:Doubla Pane with Low-E: Window 15: Vinyl Frame:Double Pane with Low-E: Window 16: Vinyl Frame:Double Pane with Low-E: W'mdow 17: Vinyl Frame:Doubla Pane with Low-E: Window 18: Vinyl Frame:Double Pane with Low-E: Window 19: Vinyl Frame:Double Pane with Low-E: Window 20: Vinyl Frame:Double Pane with Low-E: Window 21: Vinyl Frame:Double Pane wi~ Low-E: Window 22: Vinyl Frame:Double Pane with Low-E: Window 23: Vinyl Frame:Double Pane wi~ Low-E: Berezny Residence Floor 1: Slab-On-Grade:Unheated:, Insulation Depth: 2.0' Floor 2: All-Wood Joist/Truss:Over Unconditioned Space: Furnace 1: Forced Hot Air: 89 AFUE Fumaca 2: Forced Hot Air: 89 AFUE Air Conditioner 1: Electric Central Air: 12 SEER 158 10.0 121 2032 30.0 4.5 57 Compliance Statement: Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7 Rele , requirements listed in the REScheck Inspecto~ Checklist. Builder/Designer Company Name Project Notes: CONSTRUCTION OF NEW SECOND STORY ADDITION ABOVE EXISTING ONE-STORY STRUCTURE, *GROUND SNOW LOAD - 45 PSF *EXPOSURE CATEGORY B '120 MPH WIND SPEED *SEISMIC DESIGN CATEGORY - B *WEATHERING - SEVERE *WINTER DESIGN TEMP. - ZONE 11B - 11 DEGREES 'ICE SHIELD UNDERLAYMENT REQUIRED -R-3 SINGLE FAMILY RESIDENCE -HEIGHT - 25'~" FROM GRADE TO RIDGE -AMERICAN FOREST & PAPER ASSOCtATION (AF&PA) WOOD FRAME CONSTRUCTION Berezny Residence Page 2 of 7 REScheck Software Version 3.7 Release lb Inspection Checklist Date: 01/04/06 Ceilings: I~ Ceiling 1: Fiat Ceiling or Scissor Truss, R-38.0 cavity + R~.5 continuous insulation Comments: Above-Grade Walls: [] Wall 1: Masonry Block with Empty Cells:Exterior Insulation, R-9.2 cavity + R~,5 continuous insulation Comments: [] Wall 2: Wood Frame, 16" o.c., R-21.0 cavity + R-4.5 continuous insulation Comments: [] Wall 3: Wood Frame, 16" o.c., R-21.0 cavity + R~.5 continuous insulation Comments: Windows: Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: [] Wiodow 3: Vinyl Frame:Double Pane with Low-E, U-fector: 0,350 For windows without labeled U-fectors, describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No Yes No [] Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 5: Vinyl Frame:Doubfe Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No I--I Window 6: Vinyl Frame:Double Pane with Low-E, U-factor: 0,350 For windows without labeled U-factors, describe features: ~Panes Frame Type Thermal Break? Comments: Yes__No [] Window 7: Viny~ Frame:Double Pane with Low-E, U-fector: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? __ Yes Comments: No [] Window 8: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes__No Berezny Residence Page 3 of 7 Window 9: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors. desc~be features: #Panes Frame Type Thermal Break? Comments: Yes No Window 10: Vinyl Frame:Double Pane with Low-E, U-fector: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No [] Window 11: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes Comments: No [] Window 12: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: ~Panes Frame Type Thermal Break? Yes No Comments: [] Window 13: Vinyl Frame:Double Pane with Low-E, U-fector: 0.350 For windows without labeled U-factors, descdbe features: #Panes Frame Type _ Thermal Break? Yes __ No Comments: [] Window 14: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: [] Window 15: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type _ Thermal Break? Comments: Yes No [] Window 16: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeted U-factors describe features: #Panes Frame Type Thermal Break? Comments: Yes __ No [] Window 17: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: C1 Window18: Vinyl Frame:Double Pane with Low-E U-fector:0.350 For windows without labeled U-factors, describe features: #Par~es Frame Type _ Thermal Break? Yes No Comments; [] Window 19: Vinyl Frame:Double Pane with Low-E U-factor: 0.350 F~r windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? Yes No Comments: [] Window 20: Vinyl Frame:Double Pane with Low-E U-factor: 0.350 For windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: [] Window 21: Vinyl Frame:Double Pane with Low-E U-factor: 0.350 For windows without labeled U-factors describe features: #Panes Frame Type Thermal Break? __ Yes No Comments: [] Window 22: Vinyl Frame:Double Pane with Low-E U-factor: 0.350 For windows without labeled U-factors describe features: Berezny Residence Page 4 of 7 #Panes Frame Type __ Them~al Break? Yes __ No Comments: Window 23: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, descdbe features: #Panes Frame Type Thermal Break? __ Yes Comments: No F'I Door 1: Solid, U-factor: 0.350 Comments: [] Door 2: Glass, U-factor: 0.350 Comments: [] Floor 1: Slab-On-Grade:Unheated, 2.0' insulation depth, R-10.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 2.0 ff. OR down to at least the bottom of the slab then horizontally for a total distance of 2.0 ft. Exterior insulation must have a itgid, opaque, weather-resistant protactive covedng that covers the exposed (abov~grade) insulation and extends at least 6 in. below grade, [] Floor 2: Ail-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity + R-4.5 continuous insulation Heating and Cooling Equipment: Fumace 1: Forced Hot Air: 89 AFUE or higher Make and Mndel Number:. Ct Fumace 2: Forced Hot Air: 89 AFUE or higher Make and Model Number: [] Air Conditioner 1: Electric Central Air: 12 SEER or higher Make and Model Number: Air Leakage: [] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ~1 Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment must be installed in accordance with the manutacturer's installation instructions. [] Materials and equipment must be identified so that compliance can he determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [] Insulation R-values, glazing U-factom, and heating and coating equipment efficiency must be cleady marked on the building plans or specifications, Duct Insulation: [] Ducts in unconditioned spaces must he insulated to R-5. Ducts outside the building must be insulated to R-6.5. Duct Construction: [] All joints, seams, and connections must be secure/y fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [] Thermostats are required for each separate HVAC system. A manual or automatic means to pertialty restdct or shut off the Berezny Residence Page 5 of 7 0 [] [] heating and/or cooling input fl3 each zone or floor shall be provided. Sewlce Water Heating: Water heaters with vertical pipe risem must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system, Insulite circulating hot water pipes to the levels in Table 1. Circulating Hat Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is fi'om non~epletable sources. Pcol pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the tevels in Table 2. Berezny Residence Page 6 of 7 Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1 · Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Rar~je(°F) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1 · and Less 1.25" to 2.0" 2,5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Berezny Residence Page 7 of 7 Town Hall Annex 54375 Main Road P.O. Box 1179 Southold. New York 11971 0959 Telephone (631 ) 765-1802 Fax (631) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD February 2nd, 2009 FIRST NOTICE bonnaWalters Rachel Berezny P.O. Box 347 Cutchogue, N.¥.11935 RE: 10105 Oregon Rd. (Alterations/Addition) 5CTM: # 83.-2-19.4 bear Ms. Walters & Ms. Berezny: Please be advised that your Building Permit # 31754 issued ,Tanuary 25th, 2006 has expired. According to the Code of the Town of 5outhold, o Certificate of Occuponcy must be issued before the use of the structure. To renew your Building Permit, please submit a fee of $545.70; at time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 765-1802. Respectfully, $OUTHOLD TOWN BUILDIN~ DEPT Yo~',ii Hall Annex 54375 Main Road ILO. Box 1179 Soulhold, NY 11971-0959 Tclcl)honc (631 ) 765-1802 Fax (fi31) 7ti.3-9,5()2 I~,ITILI)IN(; I)EI~ARTMI.]NT TOWN OF $OUTttOLD dune 22, 20~0 Donna Walters & Rachel Berezny PO Box 347 Cutchogue, NY 11935 RE: 10105 Oregon Road, Cutchogue TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occupancy: Application of Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of $25.00. Final Health Department approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) __ Trustees Certificate of Compliance. Final Planning Board approval. Final Fire Inspection from Fire Marshal. Final Inspection from the Building Dept. Final Landmark Preservation approval. Building Permit: 34459.Z additions/alterations SITE SUNVEY SURVEY OF PROPERTY SITUATE: OREGON, CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. S.C. TAX No. 1000-83-2-19.4 SCALE: 1" = 30' DECEMBER 23, 2004 AREA : 39,999.55 SQ. FT 0,92 ACRES INFORMATIQN TAKEN FROM SURVEy PREPARED By KENNETH M WOYCHUK, LAND N/F OF PHILLIP MAUCOTEL MON LAND N/F OF TOWN OF $OUTHOLD CHAIN LINK PENCE LAND N/F OF ROBERT & SHARON CARfTA · WELL EX COHO PROP BECK EX PATIO CERTIFIED TO: DARRELL E~EREZNy LAND N/F OF CHRISTINE VONAESCB , MON t GEN, ERAL 1. ALL WORK ~R,N,.L OOM~LY WIT~'DERAL. ~I'ATE, AND LOCAL BIJILDtNG CODE AND OF~31NA~4~, ' ' FROM T~ DIM~8I~a'~. , ' 5, ~E CQ~CT~ ~ B~ RESPOnSeS F~ ~{~ATELY ~G AND CODES, ' 8. THE CONTRACTOR 8~ PAY FQ~ AL PE~B,',FEEB. A~D ~,~E~TED TO ~E WORK OF THIS CONT~ INSPECTIONS OF ~L ~RK COMPELD ~R 7. THE CONT~CTOR 8HALLAT ~ T[~ES:~P ~ P~IS~ C~N AND 1S RESPONSIBLE ~R EMOVAL OF A~ R~SH ~R ALL ~D~ F~M THE JOB B. ANY "~R~" FOR ~L OR LEG~I~TE UNFO~E~N'C~NOI~ 8HA~L ~ DOCUMENTED W~ T~ CO~ OF A ~ARTING ADDITIONAL WORK ' g. DOUBLE JOISTS ARE TO BE INST~EO ~ER ~WALL PA~ITDN~ RUNNIN~ PARA~L 30 THE F~ING; ~ROyI~F B~ H~E~ JOISt'AT ALL OPENINGS, REFER TO CONS~T D~N~ ~OR ~ES, 10. A~L F~MING LUM~R ~ BE D~U~S FIR ~2 CONS. G~E OR 11. A~ ~ERIOE S~R~PPING TO BE EN~ ~ SH~THI~. ~ 2. TH~ C~T~O~A~ P~-~,p~I~ F~ ~ SP~ WORK PROCEEDING, NEW EXTERIOR P~ARTmI~. ;I- ~' X ,6" wO(:~D,~I3,~WALL )/I//l'/2,',(~l~x PLY'WU, RE~ GYP, ~. (~E~Bp.)~R.~ ~T~ W~L ~D CEILINGS ~ COATS RNIS~ [~DL~R~D.~ ~) SATIN FIN, ~UGHOUT DRAWING LIST A.0 A,1 A.2 A.2-1 A.2-2 iA.3 A.4-1 A.5 iA.6 FOUNDATION PLAfN FIRST F ,LOOI~, PLAN SEOONB FLOOR PLAN SEOQNi~ FL~R!,DEC, K FRAMING ROOF FRAMING PLAN BUILDING SECTION/ DEMOLITION PLaN FRONT & RK~,HT 81DE ELEVATIONS REAR & LE~FT,~Ni;)E ELEVATIONS ENERGY CALCULATIONS PLUMBING RI'SER DIAGRAM ELECTRICAL L EGEND: NOTE: AU- E[~EOTRICAL WORK T° Be IN A~COFIO,~i(~E WITH T~E RU~ AND ON.O- ~WNLIGHT TRIMS TO BE WHITE ~eFI DUPL~ RE~TAC~GROUND FAULTI~ERR~PT ~ DUP~ 8EP~E CI~U~ RECEPTA~ $ W~I~CH 3 a:~y~ALL SWISH - - - ~ RECEDED ~WN~GHT ~1 ~) "LIG~QILER" OR ~PROVED EQUAL ~ E~ MOUNTED EliNT WITH FAN ~so SMOKD CARBON 'M~Q~DE DE~ECTOR: TO BE HARD WIRE~ TO CEdE CONSOL BOX 4 T NEW TELEPHONE RECEPTAC~ ~ ~ N~ STRUC~ED CAaLE ~ N~ DOORBELL X,B" ACQ F,J 16" A~OVE PLUMBING LEGEND -' J Jp PROVIDE ALL NEoEssAECr PLUMBING ROUGHIN~ AN~;~/V~J~'*TIN ~A8 IN DI~:3A~D ON CO~UCTION P~NS). FOLLOW ALL NEC~ N,Y,g. ~ N'Y,S BUILDING CODES ~AT APPLY TO WORK BEING ~MP~ED'. PR~, A~ N~CES~RY DR~N VALVES, ~HB PROVIDE FRO~ FREE HOSE BIBS. I,N $:U LAT ION - ~F~;~S~ING F--..~T. E.,~,UOR WALLS: J~)~4"' W~O ~D-;~ 5 NIGH DENSIW I NSU~TtON BY ~RTAN~E~', OR ~ROVAL EQUAL, - NEW ~IOR W~L~{ 2~~6'' W~OD ~D, ,R.21 FOIL FA. HIGH ~NSI~ INSU~TION aY ~e~, ~A~ ~, , - ~OOF' R-~8 ~-FA I~O~TI~ ~Y,'~ERTNNTEED' OR ~PROVED EQ, 0C£L F,¢ OR USE! '., ~LAWFUL, WITHOL F CERTIFICATE:', OF CCC JPANCY PLUMr F R CERTIFICATION-' OIV ! r ,. ~,oNTENT BEFORE C~ERT/h/L,,~, TE OF OCCUPANCY SOLDER USED tN WATER SUPPL¥ sYSTEM CANNOT ,,DEL, 2~ X ,/ DECK GIRDER ABOVE CC~LUMNS/~ REQUIRED TO A~OW FOR ~W OOLUM~ & ~=0OTINGiB EACH NEW ~FEEL C crYP~CAL ~L) T i BELOW AP~PRQVED AS NOTED DATE' t/~/~=~ BP # ~):~'~ NOTIFY BUILDING DEPARTMENT AT 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1, FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. ~NSULATION 4,FINAL - CONSTRUCTION MUST BE COMPLETE FOR C,O, ALL CONSTRUCTION SH~LL MEET THE REQUIREMENTS OFTHE CODES OF NEW YORK STATE, NOT RESPONSIBLE FOR nESJGN OR CONSTRUCTION ERRORS, COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIR AND CONDITIONS OF i EXCEED 2/10 OF 1% LEAD, SOUTHOLDTOWNZBA SOUTHOLDTOWNTRUSTEES UNDERWRffERS CERTIF~t~IEi REQUIRED PLUMBING N.Y,S, ALL PLUMBING'WASTE COaPLY W~H FLeD DAMAGE PRE~ENTI~ ~T~D TOWN ~DE. CERTIFICATION OF NAILING & CONNECTION~ REQUIRED. RETAIN sTORM WATER RUNOFF PURSUANT TO SECTION 45-10C OF THE TOWN cODE. N.L cONSTRUCTION SHAIJ. MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. 2 >' 1/4"=1'0" GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES AND ORDINANCES, 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR~ ~HALL FURNISH THE OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INBUR~NCE AND WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. & THE CONTRACTORS SHALL BE RESPONBIJBLE FOR ALL DIMENSIONB AND CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIEC OF ANY VARIATIONS FROM THE DIMENSIONS SHOWN. 4. THE CONTRACTOR SHALL SUPPLY A~L LABOR .AND MATERIAL SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED. 5. THE CONTRACTOR SHALL BE RESPON.~iBLE FOR ADEQUATELY BP, ACING AND CONSTRUCTION LEGEND NEW EXTERIOR PARTITION- 2" X 8" WOOD STUD WALL W/1/2" ODX PLYWD. U.O.N, ALL TR~ SEMi-(~ILOSS. OVeR 1/~" CEMENT BOARD U,O~N WALL AND FLOOR GROUT TO HAVE ELECTRICAL LEGEND: NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATtONB OF THE N.Y.B,F.U, AND A CEI~BFICATE FROM THE N.Y.B.F.U. IS TO BE PRESENTEO TO THE OWNER AT THE COMPLETION OF THE JOB. NOTE; THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE NOTED ALL OTHER ELEDTRIDAL EQUIPMENT AND MA'rE TO BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. NOTE, ALL 8WITCHES AND RECEPTACLES TO BE 'LIJTRON', 'DECORA" IN COLOR O.N.O., DOWNUGHT TRIMS TO BE WHITE, ~ DUPLEX ELECTRICAL RECEPTACLE I ~ I DOUBLE DUPLEX ELEC. RECEPT. (~{~FI DUPLEX REOEPLTACLE/GROUND FAULT INTERRUPT (~Sc DUPLEX SEPARATE CIRCUIT RECEPTACbE $ WALL SWITCH $ 3 3-WAY WALL SWITCH '~J8 CEILING MOUNTED JUNCTION BOX ~'Ja WALL MOUNTED JUNCTION BOX ~' RECE~BED DOWNLIGHT (100w) 'UGHTOtLER" OR APPROVED EQUAL ~'E EXTERIOR MOUNTED DOWNLIGHT (100W) PLUMBING LEGEND: PROVIDE ALL NEOES~:{Y PLUMBING ROUGHING AND VENTING AS INDICATED Op ON CONSTRUCTION PLANS), FOLLOW ALL NECESSARY N.Y.C, AND BUILDING CODES THAT APPLY TO WORK BEING COMPLETED, PROV. ALL NECESSARY DRAIN VALVES, ORB PROVIDE FROST FREE HOSE BIBS, ~IS SHOWER HEAD DOOR SCHEDULE: ~ATFRIAL INSU;LAT10:N ,NOTES - EXISTING EXTERIOR, wALL~; 2"X4" WOOD 8TUB, R~I 5 HIGH DENSITY INSULATION BY 'CERTANTIEEI~~ OR APPROVAL EQUAL - NEW EXTEI~OR WALLS: 2"X8" WOOD STUD, R-21 FOIL FA. HIGH DENSITY INSULATION BY 'CERTAINTEED' OR ~PROVED EQUAL. - NEV'J ROOF: R-SE KRAPT-FA. INSULATION BY 'CERTAINTEED' OR APPROVED EQ. WINDOW LEGEND: ALL W~I~DOWS TO .BE ANDERBEN CLA~, WINDOW SPECS ~' ~ ae42-2w s,-41/4. 4,-4 7~,, 2 I e I EXISTING ~O BE RELOCATED * THESE UNITS MEET OR EXCEED THE FOLLOWING .DIMENSIONS: CLEA~ QPENABLE AREA Of 5,7 SQ. ~., C~ OPENABLE ~TH OF 20" AND O~R OPENABLE HT[ Of 24" crYPIDAL) 1 3' V,I,F, PROV, FLITCH PLATE ABOVE. = 3'-8" ,~ ~ 12'V. - OFFICE 9'-1 0" X 1 1 '-0" 27'-2" FIRST FLOOR PLAN J FIRST FLOOR P~N DWi, NO.: GENERAL NOTES: 1, ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES AND ORDINANCES, 2, BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. S THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS SHOWN, 4, THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED 5, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE CODES, 6, THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO THE WORK OF THIS CONTRACT. CONTP~CTORS SHALL INITIATE ALL REQUIRED INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT, 7, THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE, 8, ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO STARTING ADDITIONAL WORK, 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING PARALLEL TO THE FRAMING, PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS, REFER TO CONSTRUCT DRAWINGS FOR SIZES, 10, ALL FRAMING LUMBER TQ BE DOUGLAS FIR #2 CONS., GRADE OR BEll ER, 11. ALL EXTERIOR STRAPPING TO BE BENEATH EXTERIOR SHEATHING, 12, THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SUCH AS BUT NOT LIMITED TO' MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE PROCEEDING. CONSTRUCTION LEGEND,' NEW EXTERIOR PARTITION- 2" X 6" WOOD STUD WALL W/1/2" CDX PLY~/D, EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), QUALITY EDGE SIDING BY "TRU-SHAKE" - COLOR WICKER APP, EQ PROV,1/2" GYP, BD,(SCREWED/TAPED) CLR, PINE 5" COLONIAL BASE TRIM, & R-21 FOIL FACE INSUL, (HIGH DENSITY). 3 1/2" WIDE CLEAR PINE COLONIAL TRIM ON ALL WINDOWS & DOORS ALL WINDOWS TO HAVE STOOL, NEW INTERIOR PARTITION- 2" X 4" WOOD STUD WALL WITH 1/2" GYP, ED, (SCREWED/TAPED) APPLIED BOTH SIDES. NOTE' PROVIDE MOISTURE RESIST GYP, ED, (GREEN ED,) FOR ALL BATHROOM WALL AND CEILINGS. PROV. CEMENT WALL ED, FOR ALL TILE AREAS, INTERIOR PAINT- TO BE "BENJAMIN MOORE" U,O,N, ONE COAT PRIMER AND TWO COATS FINISH (COLORS T,B.D, BY OWNER) SATIN FIN, THROUGHOUT U O N. ALL TRIM SEMI-GLOSS, HARDWOOD FLOORING-SELECT #1 RED OAK 2 1/4~W,, 15LB, FELT, UNDERLAYMENT, (3 FINISH COATS OF CLEAR SATIN POLYURETHANE,) SUB-FLOOR-USE 2/4" THICK PLYWOOD GLUED AND NAILED SUB FOR TILE AREAS TO BE SCREWED AND GLUED CERAMIC TILE - "AMERICAN OLEAN" TILE OR APP, EQ, TILE TO BE INSTALLED OVER 1/2" CEMENT BOARD U.O N. WALL AND FLOOR GROUT TO HAVE WATERPROOF ADDITIVE MIXED IN, ELECTRICAL LEGEND: NOTE: ALL ELECTRICAL WORK TO BB IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THE N,Y,B,F,U, AND A CERTIFICATE FROM THE N Y B,F,U, IS TO BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB, NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L, TO BE SUPPLIED BY THE ELECTRICAL CONTRACTOR, NOTE: ALL SWITCHES AND RECEPTACLES TO BE ~LUTRONI~, "DECORA" IN COLOR O,N,O,, DOWNLIGHT TRIMS TO BE WHITE, I ~)¢¢ I DOUBLE DUPLEX ELEC, RECEPT, DUPLEX ELECTRICAL RECEPTACLE (~FI DUPLEX REOEPLTACLE/GROUND FAULT INTERRUPT ~SO DUPLEX SEPARATE CIRCUIT RECEPTACLE $ WALL SWITCH $ a 3-WAY WALL SWITCH ~JB CEILING MOUNTED JUNCTION BOX J~Je WALL MOUNTED JUNCTION BOX ~ RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL 4~'E EXTERIOR MOUNTED DOWNLIGHT (100W} 'i~,jB WALL MOUNTED DUAL SPOT LIGHT ~.EF NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST FAN/LIGHT WITH DUAL SWITCH AT WALL, "BROAN" HEAVY DUTY UNIT OR APP. EQUAL, ~'F EXT. MOUNTED LIGHT WITH FAN SMOKE/CARBON MONOXIDE DETECTOR: ~ISD TO BE HARD WIRED TO CENTRAL CONTROL BOX <~ · NEW TELEPHONE RECEPTACLE "~ E NEW ETHERNET RECEPTACLE "~ ST NEW STRUCTURED CABLE Dali NEW DOORBELL PLUMBING LEGEND PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED Op ON CONSTRUCTION PLANS), FOLLOW ALL NECESSARY N.Y.C. AND N,YS, BUILDING CODES THAT APPLY TO WORK BEING COMPLETED, PROV, ALL NECESSARY DRAIN VALVES, OHB PROVIDE FROST FREE HOSE BIBS, ~IS SHOWER HEAD DOOR SCHEDULE: INSULATION NOTES - EXISTING EXTERIOR WALLS' 2~'X4" WOOD STUD. R-15 HIGH DENSI"FY INSULATION BY 'CERTANTIEED~ OR APPROVAL EQUAL. - NEW EXTERIOR WALLS: 2"X6" WOOD STUD, R-21 FOIL FA, HIGH DENSITY INSULATIO[ BY "CERTAINTEED' OR APPROVED EQUAL, - NEW ROOF: R-38 KRAFT-FA. INSULATION BY 'OERTAINTEED' OR APPROVED EQ. WINDOW LEGEND: ALL WINDOWS TO BE ANDERSEN CLAD. WINDOW SPECS ANDERSEN ROUGH ROUGH REFERENCE OPENING OPENING QTY. NUMBER WIDTH HEIGHT ~ TW 210410-2W* 6'-0 1/4" 5'-0 7/8" 3 I~)1 EXISTING TO BE RELOCATED 2 * THESE UNITS MEET OR EXCEED THE FOLLOWING DIMENSIONS: CLEAR OPENABLE AREA OF 6,7 SQ. FT,, CLEAR OPENABLE WIDTH OF 20" AND CLEAR OPENABLE HT. OF 24" M. BATHROOM 9'-1" X 9~-7'' M. CLOSET 6'-6" X 9'-7'r STUDY 1 '-4" X PLAY RM. 1 3'-7" X 1 1 '-4" LIVING ROOM 1 6'-0" X 1 5'-9" 8' V.I.F. M. BEDROOM 1 6'-0" X 1 7'-4" TRAY CEILING 1 2'-6" 12'-6" V.I.F. 333 12'-10"// -- Jd;)F"__ I 16' TRAY CEILING 10' HT. 16 V.I DN. 10'-3" [ 13'-5" CENTER BELOW RIDGE 32' MEDIA ROOM 8'-10" X 13'-0" BATHROOM 9'-0" X 9'-8" 14'-4" GFI SECOND FLOOR PLAN 17'-3" LLIz >- B t~O SCALE: 1/4": 1 '0" DWG NAME: SECOND FLOOR PLAN DWG. NO.: A-2 PER RE~f~IE;NT~ ~ h~',,Y~[K ~,T,~T1~R~i~D ~l~rT?L CONSTRUCTION COE)E WE C E~TI IFy ~'HA~ 3'~ ~ ~. cii~, I~,a~' IS ,[~O ~,~ PES;I F~ESCF~PTIVE DESIGN, .e~LLOF ~'~1E ~CAL~t.g;.ATIONS'A~I,D S~CTtJRAL Pt~NS COMPLY WITH ALL OF Nr~'W '¢~RK CON~':I~[JCTION COE)E I~*.SEE3 ON ( AF~,'PA ) FOR ON~-FAMILY DWELLING TO THE BEST OF ~ KI'4OWL.EDGE, NOTES: 1. ALL WOIR~ SHALL COMPLY WITH FEDER/~.L, STATE. AND LOCAL BUILDING CODES ANE) Of~DINANICE~: 2, BEFORE CO~EN~ME~ ~ WOR~ ~E CON~OR8 ~L FU~ISH ~E ~R AND ~CT W~ C~ OF A~ ~Ul~ INSU~CE ~D WORKER'S COrONaTION CE~F~S ~D N~ES ~ A~ SUB-CONT~OR8 TO MAKE CON NECTI~ ~ THESE ~. ALL ~ ~ ~ HAN~a~~ STILL USE JOIST S ~0 A~ACH TO' ~MS AT ~ FLUS~ ~ND~ IN ~PI~AL F~ION THESE [3RAWI'NGS ARE FOR REFERENCE ONLY AND THEY' ARE NOT INTENDED TO BE SCALED, 2- 1 3/4" x 11 7/8" MtCROLLAM SEAM SECOND FLOOR FRAMING PLAN EXACT LOCATION OF IN FIELD AT 10' C,T, HEIGHT SECOND FLOOR CEILNG FRAMING P' N, NOTF: PER R~OUFRE~ENTS BY NEW yORK STATE RESI,DENTIAL I~ONST~IUC~tON DESIGN. ALL OF ~E L~D ~C~TI~'~ =~U~U~ R~S C~PLY WITH ~L OF NEW YORK O~S~G~M ~DE ~0 ON (A~ '~ FOR ONE-F~LY ~G ~ ~ B~T ~i~ ~NOW~. GENERAL NOTES: ' ' ' ' i , NO JOIST HANGERS ARE TO I. ~L W~K SHALL cOMPLY ~DE~L, 9TA~ A'~OC~ aUILDI~G CODES a~M~,, 0 '. HER ~ND ARCHI~OT WiTH COR~E~ ~F AL RE~UJRED IN~CE AND AT ALL FLUSH CONDI~S IN ~I~AL FA~ON W~RKER~ COMPENSATION CERTIFI~ AND NAM~ OF ALL SOB-CONT~CTORS. PFIOV, 2~' X 4" ON FLAT "FLYING RAKE" AT ALL (3/I~LE ENDS, (TYPICAL ALL) 2- I 3¢4" X 14" MICROLLAM 7/El" MICROLLAM ,271,3/4".~ 14'I MI~ROLLAM RtDG~ BEAMi 2;1 ~4" X 11 7/8" MICROLLAM BAND JOIST TO 8UP~ ~, 8]MP~N L~12 I~0 ~OO~ ~01~ A~ ~PPORT B~ CONNECTiON OF FLOOR FRAMING ~/DI"~ TO SU? .Frr aEAM (~vlPLE) (RPS4) TB~ BRACING (MT$12) NAILS OR STRONG *WALL PR -A~?FAC F'~E E~ PI'~6 WITH - S D TO STUD (~Js ~ 61 STUD TO B,e~D JOIST HEADER ANCHORAGE (LSTA1 B) 11 7/ar' S~)X BEAM REF. TO A-3 FOR PI~t~G TO GIRDER CONNECTION. PR , M~CAL F , I MI: I AL FASTENER'SCHED~! :F (ALL STRAP~NG TO BE @ ~6" C.C.) PfROV. 2~ X 4" C RIDGE ~STENER BEAM ~ / / (STPC, P REQUIRED FOR 16" JOIST CONNECTION OF RIGDE ~ B~M TO 'ROOF RAPI ER (E~MPLE) SCREW THROUGH ~FIACE AT EACH X- BRACING (EXAMPLE) WALL (3) 2"X 10" HEADER F WALL JACK STUDS CONNECTIONTo WI'HDCWOF WALLHEADERSHEATHING (EXAMPLE) CLIP ANGLE (~TH SIDES OF CONNEt2';i3ON) MIN. LENGTH = JOIST V'~ DEF~H M~NUS 1 ~ JOIST TO HEADER JOIST (EXAMPLE) (2) 2"X 4~' TOP PLATE R -- WITH (7) 10d X I 1/2 F~NER BIRDSMOUTH, CUT,, ,LOW END OF JOIST ONLY (EXAMPLE) CORNER(EXAMPLE) CONNECTION ;10" STUDS CO_NNECTION OF V~ALL,SHF-ATt"iINr~ (EXAMPLE) N I N OF ~m" 7,, ' X 4'~, ON F ,i, NOTE: - REFER TO h.1 ~ A,2 WINDOW'~ ~,~l.~bF-~ Fl~ PANEL LOCATIoN,~. ALTERNATIVE FOR OPENING PROTECTION WOOO STRUCTURAL PANEL.SWITH A M'INiMUM' THICKNESS OF 7/1 $" AND MAXIMUM PANEL SPAN OF 8'-0r' SHALL~-PERMI3-rEDF?ROF~'NINGPR~ii~!~'*tlNON~ND'~/OSTORYBUILDING8 PANELS SHALL E~E PRECUT TO COVE~ GLAZED O~ENIN~$ WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SSCTION 1609.1 ,4 .ad~D 1609,6~5 AND TAELE 1609.1 TABLE 1609.1.4 WINDBORNE DESRI$ PRO"I;ECTION FA,?JTENING SCHEDULE FOR WOOD STRUCT~L P~ELS PANEL SPAN ~ 2'-0" c PANEL 4'-0" < PANEL 8'-0" < PANEL REMOVE EXISTING WINDOW PANEL LEGEND (REFER TO TABLE 1809.1.4) PANEL SIZE REF. WPE AND ~f~ OF SCREWS WIDTH t HEi(~RTI O~. "E'* HORiZ0~ - 3 VERTi~L - 8 3'-8" X 5'-0" 6 ~8 SCR~ ~ ~ O.C 5'-11" FRONT ELEVATION CONT. RIDGE & HiP VENT BY '~COBRA" OR APP. FO. ('~P, ALL AR~) Dt~L ~ I 3/4~ X 14" G-P LAM DBL- I 3/4" X 14" G'-P LAM LJEU OF RtMJOIST ABOVE ALL. 1 ST FL, DOORS~V~N DOWS Cc, q=.. ALL) DENS EXT WALLS (TYp ALL) ~CONT. PROV, 5/~" ODX PLYWOOD ALL ROOF AREAS.) /2" GYP. BD ALL EXPOSED AREAS WALL PROV R-E1 Hi(iH DENS. INSULATION (TYPO /2" GYP. SD. ALL EXPOEED AREAS. ALL CEILING AREAS) (TY'F ALL) R-30 FOIL FACED INSULATION 1 3/4" X 1 ~ 7/8" MICROLI. AM LVL SlSTEI~ED TO EACH SIDE OF EXIS?tNG DEL Z' X 6" BEAM R-30 FOIL FACED INSULATION INOTE: REMOVE EXISTING COLUMNS AS REQUIRED TO ALLOW FOR NEW COLU~INS & FOOTINGS J " J PARALLEL FART (TYP ) /8~/-CUT HOLE IN FLOOR. AS REO~), PROV, OQt~Ul~lN FLANGES WIDE EN~ 't~O A(;COI~ODATE FOR ALL 8TRUGTUR~L MEI~BE.I:~. ALL) [ DI~L I 3/4"~X 1~1 7,~' LV&, ~ LATH ALL P~RALLEL P,,,~'~'r. Ci~P.) BU! LDING SECTION >. t 1/4"= 1 '0" BUILDING SECTION & DEMO P~ ~G. ~0.: 25' RIDGE HEIGHT r~TOP OF WINDOW II SECOND FLOOR CTOP OF WINDOW FIRST FLOOR PROV. LIFETIME GC, F ASPHALT SHINGLES (TYPICAL ALL) 6"' WHITE CONT. GUTTER ¢rYp. ALL) SOFFIT. PROV, 1" SOFFIT VENT P LYVv'OO D BLOCKING ROOF SHINGLES. OVER 15 LB. FELT. PROV. "WEATHER WATCH" UP 2'-O" OF ROOF EDGE, WATCH" UP 2~-CI" ). EQ,) PROV. 6" EXPOSURE CLEAR CEDAR SHAKES" PERFECTIONS" (OR APPROVED, EQ.} FRONT ELEVATION PROV. LIFETIME "GAF" AgPHALT ROOF SHINGEES. ('TYP. OVER 115 LB. FELT. PROV. PROVIDE AZEK SEADSOARD ,1"SOFFIT VENT PROV. 6"EXPOSURE CL~R CEDAR SHAKES"PERfECTIONS" (OR APPROVED. PG.) PROVIDE 5 1/2" AZEK WINDOW, DOOR, SOFFITS & FACIAS, (TYP, ALL LOCATIONS) PR~V, 6" EX~ UaE C CEDAR S~AKES" RIGHT SIDE ELEVATION EL~AETIONS WHITE CONT, GU I I ER ¢'YPICAL ALL) PROV. LIFETIME GAF ASPHALT SHINGLES (TYPICAL ALL) SOFFIT. PROV. 1" SOFFIT VENT PROVIDE 6" "AZEK" TRIM BLOCKING. (TYPICAL ALL) PROV. LIFETIME "(3AP' ASPHAL~T ROOF SRINGL~ES,. (TYPJ/E.L AREAS) OVER 15 LOB. FELT PROV, "W~e*,THER WATCH'* UP Z-O" OF ROOF EDGtE REAR ELEVATION i~;,,' t It OVER 16 LB. FELT. PROV. 'V,/EATHER WATCH" UP 2'-0" OF ROOF S~GE. (OR AF'PRO~/ED. SQ.) Q SHAKES" (OR APPROVED SQ.) LEFT SIDE ELEVATION A-4 GENERAL NOTES: I FAMILY DETACHED DWELLING ZONE 11B HEATING DAYS ~ 5750 COINCIDENT WET-BULB TEMP = 78 SUMMER DESIGN DRY - BULB TEMP = 83 WINTER DESIGN DRY-BULB TEMP ~ 6 GLAZING U FACTOR = 0,48 CEILING R VALUE = R-38 EXTERIOR WALL R VALUE = R-21 MINIMUM EQUIPMENT PERFORMANCE PERSPECTIVE BUILDING ENVELOPE REQUIREMENTS WINDOW AREA 30% OF GROSS EXTERIOR WALL AREA MAXIMUM MAXIMUM HEATING GLAZING CEILING EXTERIOR WALL FLOOR BASEMENT WALL SLAB PERIMETER CRAWL SPACE DEGREE DAYS U~FACTOR R-VALUE R-VALUE R-VALUE R-VALUE R-VALUE & DEPTH WALL R-VALUE ZO N E 11 B 0,45 R-38 R-21 R~30 R-10 R-9,2 PT R-19 5750 CLIMATE-SPECIFIC REQUIRED & PROPOSED PROPOSED MINIMUM NOTES; DESCRIPTION R-VALUE R-VALUE WALL TYPE I 2"X6" W,D.STUD R - 21 R - 21 2" X 6" WOOD STUD WALL WITH CDX PLY WD, WALL TYPE 2 2"X4" W,D,STUD R-13 R-13 2" X 4" WOOD STUD WALL WITH 1/2" GYP. BD CLIMATE AND GEORGRAPHIC DESIGN CRITERIA TABLE 301,2 (RESIDENTIAL CODE OF NEW YORK) GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM ~'~ WINTER ICE SHIELD SNOW DESIGN DESIGN UN DERLAYMENT LOAD SPEED (MPH) CATEGORY WEATHERING FROST LINE DEPTH TERMITE DECAY TEMP, REQUIRED LOAM BEARING VALUE OF EXPOSURE CATEGORY B SOIL 3,000 PSF MODERATE TO SLIGHTLY TO 45 PSF 120 MPH B "SEVERE" 12" FOOTINGS HEAVY MODERATE ZONE 11B ~ 11D YES HEATING & COOLING CRITERIA ZONE 11B DETACHED ONE FAMILY WALLS, MODE ' HEATING OR COOLING 0 14 ROOF CEILING 0,031 UNHEATED SLAB ON GRADE 4,5 BASEMENT WALL a,b, 0,1 CRAWL SPACE WALL 0,06 GENERAL FLOOR PLAN NOTES 1 , DIMENSIONS SHALL TAKE PRECEDENT OVER SCALE DRAWINGS (DO NOT SCALE DRAWINGS), 2 ALL INTERIOR WALLS TO BE COVERED WITH 1/2" GYPSUM BOARD WITH METAL CORNER REINFORCING, TAPE, FLOAT, AND SAND (3 COSTS), 3, WALLS COMMON TO GARAGE AND HOUSE TO HAVE A LAYER OF 5/8", FIRE RATED GYPSUM BOARD AT GARAGE SIDE WITH 5'-0" RETURN ON ADJACENT WALLS AND CEILING MANUFACTURED LUMBER REQUIRES 2 LAYERS OF 5/8", FIRE RATED GYPSUM BOARD 4, ALL BATH AND TOILET AREA WALLS ANT CEILING ADJACENT TO WET AREAS TO HAVE WATER RESISTANT GYPSUM BOARD, OF WALL TILE SET ON WONDERBOARD OR EQUAL, GENERAL FRAMING NOTES I ALL WALLS, 2'X4" AND 2"X6", TO BE STUD GRADE OF BEarER 16" O/C ALL OTHER FRAMING MATERIAL GENERAL ELEVATION NOTES 1, EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS, WALLS, CHIMNEYS, PROJECTIONS, AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION PRACTICES, 2, GENERAL CONTRACTOR TO PROVIDE ADEQUATE A~FIC VENTILATION AND ROOF VENTS 3 PROVIDE APPROPRIATE SOFFIT VENTILATION AT OVERHANGS. GENERAL PLUMBING NOTES 1, PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODE AND SAFETY REQUIREMENTS, 2. IF WALL PLATES OR JOIST ARE CUT DURING THE INSTALLATION OF PLUMBING FIXTURES OR EQUIPMENT PROVIDE BRACING TO THE FRAMING BACK TOGETHER GENERAL HVAC SYSTEM NOTES 1 , MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS 2, HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER 3, HVAC SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWING AND SUBMIT IT TO GENERAL CONTRACTOR, OWNER, AND EQUIPMENT SUPPLIER FOR FINAL REVIEW AND APPROVAL, EMERGENCY ESCAPE AND RESCUE OPENINGS SECTION R310 1, MINIMUM OF ONE EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED IN EVERY SLEEPING ROOM, 2, OPENING SILL HEIGHT TO BE A MNIMUM OF 44 INCHES ABOVE FLOOR, 3, NET CLEAR OPENING SIZE TO BE A MINUMUM OF 5,7 SQUARE FEET, 4 MINIMUM OF 5,0 SQAURE FEET REQUIRED FOR GRADE FLOOR OPENINGS, 5, MINIMUM NET CLEAR OPENING SILL HEIGHT LOCATED BELOW ADJACENT GROUND ELEVATIONS, WINDOW WELL REQUIRED ALLOW FOR DOOR OR WINDOW TO BE FULLY OPENED, 6, MINIMUM OF 9 SQUARE FEET IN HORIZONTAL DIMENSION, MINIMUM WIDTH OF 36 INCHES (ENCROACHMENT OF 6 iNCHES PERMIq[TED FOR LADDER OR STEPS), 7 PERMANENT COMPLYING LADDER OR STEPS WHERE VERTICAL DEPTH EXCEEDS 44 INCHES. 8, BULKHEAD ENCLOSURES WITH DIRECT EXTERIOR ACCESS PERMIttED IF IN OOMPLIANCEWITH MINIMUM NET CLEAR OPENING REQUIREMENTS 9, BARS, GRILLES, COVERS AND SCREENS PROHIBITED UNLESS DEVICES RELEASABLE OR REMOVABLE FROM INSIDE WITHOUT USE OF KEY, TOOL OR EXCESSIVE FORCE. NAILING SCHEDULE PRESCRIPTIVE DESIGN TABLE 3,1 (AMERICAN FOREST & PAPER ASSOCIATION CONNECTION FASTENING SPACING NO. COMMON FLOORS, WALLS, AND CEILINGS OVER OUTSIDE AIR. INSULATION DESCRIPTION R-VALUE U - FACTOR × AREA UA CEILING R-38 0.31 1826 SQ,FT 566 INTERIOR FLOOR R-30 0,31 1368 SQ,PT, 424 EXTERIOR WALLS R-21 0,31 2832 SQ,FT, 878 TOTAL AREA 6026 SQ, PT, WALLS, WINDOWS, AND DOORS INSULLATION DESCRIPTION R-VALUE U - FACTOF x AREA = UA WALL R-21 Uo=0,14 2832 SQ,FT, 396 DESIGN CRITERIA REF. TABLE R301.2(2) AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA) WOOD FRAME CONSTRUCTION 23.7 ° D 36 3 -30.3 ° ° -46,4 ROOF > 30 -40 Xl.53 ROOF> 30 -40 Xl,53 WIND SPEED 120 M/HR DESIGN CRITERIA REF. TABLE 1609.6.2.1 (1) MAIN WlNDFORCE-RESISTING SYSTEM WIND LOADS FOR A BUILDING WITH ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE Ba WIND LOAD ROOF HORIZONTAL LOADS VERTICAL LOADS VELOCITY DIRECTION ANGLE WINDWARD END ZONE INTERIOR ZONE END ZONE INTERIOR ZONE OVERHANG A/ALL ROOF WALL ROOF WINDWARD _EEWARE WINDWARD LEEWARE END !NTERIOR ROOF ROOF ROOF ROOF ZONE ZONE TRANSVERSE 30°<ANGLE%45° 25,7 17,6 20,4 14,0 9,9 -15,6 8.6 -13,4 -11.6 -13.0 120 23.7 ALLANGLES 22,8 -11 9 15 I -7,0 -27,4 -15,6 -19.1 -12,1 -41.1 -32.7 R-3 SINGLE FAMILY RESIDENCE OCCUPANCY & HT. CLASSIFICATIONS MIN, REQUIRED PROPOSED USE MIN. REQUIRED PROPOSED SLOPE HT,/FURED HT. SLOPE HT,/FURED HT. LIVING ROOM N/R 396 SQ,PT, N/R 7'-6" N/R 8'-0' PLAY RM, N/R 160 SQ,FT, N/R 7'-6" N/R 8'-0" STU DY N/R 194 SQ, FT, N/R 7'-6" N/R 8'-0" BATHROOM 30 SQ, FT, 72 SQ,FT. N/R 7'-6" N/R 8'-0" M, CLOSET N/R 62 SQ,FT. N/R 7'-6" N/R 8'-5" INTERIOR ENVIRONMENT SECTION 1202.4.1 & 1204.1 NET GLAZED QPENABLE USE SQ.FT,OFAREA LITE/SQ,FT, AREA% VENT/SQ.FF AREA% LIVING ROOM 396 SQ,FT. 58 SQ,FT, 10% 28 SQ,FT, 5% PLAY RM, 160 SQ,FT, 87 SQ,FT. 54% 76 SQ,ET, 48% U.Iz m >- D U.io SCALE: 1/4"= 1 '0" DWG. NAME: ENERGY CALCU~TIONS A-5 FASTEST MILE WlNDSPEED (MPH) RGOF SPAN (pt) 282 327 371 416 461 191 2`5O 32 CONNECTOR UPLtFT LOAD, .S ; L~ I L' S REQUIRED CAPACITY OF CONNECTION (LBS)~ ' ~ 8o9 12O 341 421 5OO ,58O 66O 74O 82O 110 427 526 626 7'26 826 927 1027 539 CONNECTOR LATERAL LOAD, (PERPENDICULAR TO THE WALL) CONNECTOR SHEAR LOAD, (PERALLEL TO THE WALL) TASULATED UPLIFT REQUIREMENTS ASSUME A ROOF/CEILING DEAD LOAD OF 10 PSF(2/3 X 15 PSF), SILL OR BOTTOM PLATE TO FOUNDATION ANCHOR BOLT CONNECTIONS RESISTING LATERAL & SHEAR LOADS PRESCRIPTIVE DESIGN TABLE 3.2A ALTERNATIVE TO TABLE 3,2 (AMERICAN FORES T & PAPER ASSOCiATiON) 1/2" ANCHOR BOLTS 5/8" ANCHOR BOLTS ANCHOR BOLT CONNECTION FOUNDATION SUPPORTING 2 STORIES BRACING WALL PERIMETER EDGE NAIL SPACING ALl_' FASTEST-MILE WIND SPEED (MPH/ 23 FASTEST-MILE WIND SPEED (MPH) MAXIMUM ANCHOR BOLT SPACING (IN) 36 19 28 36 57 tJ ~ CONNECTOR UPLIFT LOAD L = CONNECTOR LATERAL LOAD. (PERPENDICULAR TO THE WALL) S CONNECTOR EH~J~,R LOAD (PERALLEL TO THE WALL) ANCHORAGE REQUIRED TO RESIST LATERAL LOADS SHALL BE DETERMINED IN THE FOUNDATION DESIGN PER SECTION 1 , 1 4 ANCHOR BOLT SPACINGS BASED ON M/~(IMr. JM SHEAR CAPACITY OF UNBLOCKED ROOF AND/OR FLOOR DIAPHRAMS (279 PLF) ANCHOR BOLT SPACINGS BASBDON MAXIMUM SHEAR CAPACITY OF BRACING WALL PERIMETER EDGE NAIL SPACING OF 3" O C. (731 PLF) BUILT IN ACCORDANCE WITH SECTION 3.4 4, SILL OR BOTTOM PLATE TO FOUNDATION ANCHOR BOLT CONNECTIONS RESISTING UPLIFT ANCHOR BOLT CONNECTION FOUNDATION SUPPORTING: FASTEST-MILE WIND SPEED (MPH) (SLAB-ON-GRADE) MAXIMUM ANCHOR BOLT SPACING (IN) 72 72 72 72 ] 40 33 28 25 FASTEST-MILE WIND SPEED (MPR) 90I 100 i 110 ] 120' MAXIMUM ANCHOR BOLT SPACING (IN) SILL PLATE TO FOUNDATION* (CRAWL SPACE OR BASEMENT) t -3 STORIES 72 1-3 STORIES 32 72 72 72 51 42 36 ,.,Ell ~NC~ JCdqT TO TOP PLATE LATERAL AND SHEAR , .(JNNE, EjTION REQUIREMENTS d-t ~ UPLIFT STRAP C;'O,NN'ECT,~N ~EQU. iREMENTS (ROO'F-TO,-VVALL, WALL-TO-WALL,, AND WA L,L-TO- FO UN DAT IO N) FASTEST-MILE WIND SPEED (MPH) MAXIMUM AN¢~*HOP~ BOLT 3'-z' BATH '- I/8' SLOPE PER I PRESCRIPTIVE DESIGN TABLE 3.3B ALTERNATIVE TO TABLE 3,3 (AMERICAN FOREST & PAPER ASSOCIATION) FRAMING SPACING ROOF SPAN (IN) -3'-8 .... 6' 6' 20 M BATH M. BATHROOM 24 28 32 CONNECTOR UPLIFT LCAD NUMBER OF 8D COMMON NAILS END OF 1-1/4" X 20 GAGE STRAP~'~ 2 3 3 3 2 3 3 4 3 4 3 4 4 5 -----3'-9" 5' 3'-10" PLUMBING RISER DIAGRAM N.T.S. 3'-5 it 51 x, BATH I TOILET, BATH AND SHIOWER SPACED SCALE: 1'= 1/4" KITCHEN TO APPROVED SANITARY SYSTEM >.. D SCALE' 1/4" ~ 1 '0" PLUMBING RISER DIAGRAM DWG, NO.: A-6