Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
35307-Z
FORM NO · 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34385 Date: 06/04/10 THIS CERTIFIES that the building SOLAR PANELS Location of Property: 630 ORIOLE DR (HOUSE NO.) (STREET) County Tax Map No. 473889 Section 55 Block 6 subdivision Filed Map No. __ Lot No. __ SOUTHOLD (HAMLET) LOt 15.8 cDnforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 7, 2010 pursuant to which Building Permit NO. 35307-Z dated JANUARY 19, 2010 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SOLAR PANELS ON AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JOSEPH & PATRICIA COWLEY (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMEN~OFHEALTHAPPROV~L N/A ~.RC~rKICAL c~KTIFICATE NO. 12822 04/22/10 PLUMBERS c~TIFICATION DA'r~u N/A // Au 't~riz~ Signature Rev. 1/81 Form No. G TOWN OE $OUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with thc following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consenl to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees t. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $I5.q0 [ Date. tL>all \ New Constmc~ Location of Property: Old or Pm-existing Building: House No. Street OWner or Owners ofProperty: ....~:~xex v 'Suffolk Cowry T~ Map No 10~, S~tion ~ Sub~sion : ~ ~ ~ ~ ~ n 0o~ ~ P~tNo. ~ gbO~ ~ ~ DateofP~it. H~I~ D~t. Appro~: Plying Bo~d Approval: Request for: Tempo~ Ce~ificate (c~ck one) Fee Submitted: 12'X' 2 Lot Filed Map. , Lot: Applicant: '-'~oSl:& Underwriters xApproval: Final Certificate: Hamlet (check one) ~x~Applicant i~nature SIJFFOI K+Q B l.I FI E A U .~ 40 Nottingham Drive, Middle Island, NY 11953 Telephone:6314958136 · Fax:6319806455 · E-Mail:SBEIGS@gmail.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Rough In Inspection Date: Application No.: LIPA Solar App No.: County Tax Nap No.: Green Logic Certificate No.: 12822 Final Inspection Date: Apr 22, 2010 12822 Building Permit No.: 35307Z 08-4643-SP This Certificate of Electrical compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant named above, located at the premise of and not after the final inspection date above: Owner: 3oe Cowley Site Location: COWLEY, 630 Oriole Drive, Southold, NY 11971 Owner's Address (if different): J-'TI Residential [] Indoor L~_ Basement [] Service [] Shed [] Commemial ~ Outdoor [] First Floor [] Pool [] Hottub [] New [] Renovation [] Second Floor [] Attic [] Garage [] Addition [] Survey Other: photovoltaic system INVENTORY Single Phase 150a Heat Duplex Recpt Ceiling Fixture HID Fixtures Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixate CO Detect Sub Panel AC Blower Range R~cpt Flourescent Smoke CO Combo Transformer Appliances Dryer Recpt Emergency Tirm~ Clock Disconnect Switches Twist Lock Exit Fixtures Pumps GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan Other Equipment: Install 14 SunPower SPR215WHT and 29 SunPower SPR230Wl-IT panels. 2 SunPower SPR3000m and 1 SunPower SPR5000m inverters 9680 Total watts IIIIIAND SERVICE CHANGE///I150a under ground service up grade The electrical work and/or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements and this office. Applicant: Green Logic Inspected By: Roger Richert Signature: ~"~-~. ~ License No.: 43858-ME Date Of Certificate: Apr 23,2010 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION REMARKS: DATE [ ] ROUGH PLBG. [ ] INS~ULATION [ ~"~NAL [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION INSPECTOR~ ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35307 Z Date JANUARY 19, 2010 Permission is hereby granted to: JOSEPH COWLEY 630 ORIOLE DR SOUTHOLD,NY 11971 for : INSTALLATION OF SOLAR PANEL ELECTRIC SYSTEM TO AN EXISTING DWELLING AS APPLIED FOR at premises located at County Tax Map No. 473889 Section 055 pursuant to application dated JANUARY Building Inspector to expire on JULY 630 ORIOLE DR SOUTHOLD Block 0006 Lot No. 015.008 7, 2010 and approved by the 19, 2011. Fee $ 200.00 Authorized Signature ORIGINAL Rev. 5/8/02 Pacifico Engineering PC PO Box 1448 Sayville, NY 11782 www.paciflcoengineering.com May 6, 2010 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Joe Cowley 630 Oriole Dr Southold, NY 11971 Engineering Consulting Ph: 631-988-0000 Fax: 631-382-8236 engineer@pacificoengineering.com I have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2007 NYS Building Code, and ASCE7-05, specific to the fastening of panels to the roof, to comply with the NYS code re: 120 mph winds. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer r,zun INSpECTIoN REPORT DATE , , ,, COMiVI~NTS FOUNDATION (15T) ~ ~ FO~ATION (2~) . ROUGH~G& ~ ~ STA~ E~R~ CODE ~D~ION~ COmNTS 0 T~)WN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SouthaldTown.NorthFork. net Approved (//~, 201 0 Disapproved a/¢ FER ,IT NO. I5i07 BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey_ Cheek Septic Form Flood Permit Storm-Water Assessment Form Contact: Phone:~:~l ~::]'=~1- ~ IS~.. ~ t I '~ ~ Building Inspector PLICATION FOR BUILDING PERMIT I ate I - q ,2o t(') INSTRUCTIONS [etely filled in by typewriter or in ink and submitted to the Building Inspector with 4 ~ accorffmg to schedule. and o f buildings on premises, relationship to adjoining prem~es or public streets or c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the prenfises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any pu~ose what so ever until the Building Inspector issues a Certificate of Occupancy. fi Eve~- building permit shall expire if the work authorized has not commenced within 12 months at%er the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecFmg the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new I~mmt shall be required. APPLICATION IS HEREBY MADE to the Builffmg Daparhnent for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction o f buildiags, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. Crreer~ LO, lC, .. -- (S~gn~ o f~plicm~t or name, if a corporation) ~O~o~-Oc~ ,~ (Mailing ~ddress of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name or owner o f premises~-'tD~' ~~r~ CII~C)/,'~J / C ~'~ '7 - (As on the t/tx roll or latest deed) If applicant is a corporafic~a ~;~,n~ture of. duly authorized officer ~corporate officer) Builders License No. t_~ O ~:~v-~ ~ [_~/_~ C ~ "~ Plumbers License No. Electricians License No. I_[,"x~, ~-.~ _ 1'~----~ (~..~D X/) Other Trade s License No. 1. Location of land on which proposed work will be done: ~. House Number Street Hamlet County Tax Map No. 1000 Section ~ ~ Block Subdivision Filed Map No. Lot [% ' C~> Lot 2. State existing use and occupuncy of premises un~d intended use and occupancy of proposed construction: a. Existing use and occupancy ~r~.ff_ ~r-t~Ct'Xt Ox_~ b. Intended use and occupancy (7..)Y\J[ ~'~tAfl-lt 0x~-. 3. Nature of wurk (check which applicable): New Building_ Addition Alteration Repair Removal Demolition Other Work~t'OO{2 I~Ao,,xr~ Fl~ff'Ovot't'catc_ (D escription)~oO [(..( ~x4 ~+~'('~ 4. Estimated Cost ~),~,/.~'~(~5 Fee (To be paid on filing this application) 5. Number of dwelling units on each floor If dwelling, number of dwelling units If garage, number of mrs 6. If business, commercial or mixed occupancy, specify nature und extent of each type of use. 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear .Depth Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear .Depth Height Number of Stories 9. Size of lot: Front Rear .Depth 10. Date of Purchase t Z [ Zt::>l [ C~ ~ Name of Former Owner~-~ ~'c-~c'- ~- ~. 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ 13. Will lot be re-graded? YES __ NO V/Will excess fill be removed fi'om premises? YES NO v/ 14, Names of Owner ofpremisesS>O.h~.t. Wor~,ocd Address ~o$O Or ~ole. IM,~n°e~o.4~ Name of Architect c_o~,.~· ,~ Address Phone No NameofContracto~V'e'~nLO~tc~, ~.. AddressqZ<; 1 $ a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ' NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BEj~EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at l 0 feet or below, must provide topographical data on survey. 18. Are there any covenants and resh'ictions with respect to this property? * YES NO ~ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) --~--~ ~ [~lc~tFh being duly sworn, deposes and says that (s)be is the applicant - ~X!ame of individual signifl~contmct) above named, (S~ is the t~ c~(-XJCy'-LgC._'~-tD(~ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me th/s NO~ Public BARBARA A CASCI~TTA Notary Public-State of New York No 01-CA48~969 Oualified in Suffolk Ooonty My Commission ExCres May ~ 1, LOT5 N5~ 25' 4ff'W TLTLE:]NO: BAC 10780-S Cemm~ Land T'dJe instance Co. P~ Jord~m Cowley SF-,C~ON 55 BI~CI~ 6 COON'TY OF SUFFOLK LOT 15.0D8 TOWN OF $O(.i'THOLO LOT6 LOT 1 249.3;8' O]~Y,,A.LD T. 013UCiCL'A'Y, STATE Ol~ HL%V YORK_ 2 6 7 8 9 Yes No BARBARA A CASCIOTIA FORM - ~ua!ified in Suffolk Countv ' My Commission Expires May TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER ACR. ., TYPE OF BLD. PROP. CLASS O LAND ! 7~o0 IMP. /~0 /~ O0 TOTAL 6'YO0 DATE VILLAGE ~ D~§T'.1 SUB: LOT 5 FRONTAGE ON WATER FRONTAGE ON ROAD DEPTH BULKHEAD TILLABLE WOODLAND MEADOWLAND HOUSE/LOT TOTAL COLOR 'h~'l~d~'~ .~e:~ ~ -- I~0~ ~ ~ ~ Foundation ~ Bath Dinette ~ .~ Basement ~ Floors Kit. Extension - Ext. Walls ~. ~ ~nterior F~nish L_R. ~t~sion Fire Place ~ Heat D.R. ~ ~ ~ ~ Woodstove BR. Porch Dormer Fin~ B. Deck Attic Breezeway Rooms Ist Floor Garage ~ ~ ~ ~ ~,~E ~,~ ~f/A-~ O.B.. 'lk)wn lt;tll A.ncx 54k~73 Main Road P.O. Box 117!~ Sour[told, NY 115)71-05~,551 Telephol~C (631) 7d.5-180~2 Fax (6211) BI IILI)IN(3 I)EPARTMENT TOWN OF SOUTHOLD May 13, 2010 Joseph Cowley 630 Oriole Drive Southold, NY 11971 leaseprovide the certification the Building Inspector requested on 4/23/10. TO WHOM IT MAY CONCERN: The following items are needed to complete your Certificate of Occupancy: ~ Application of Certificate of Occupancy. (Enclosed) '~7-~ Electrical Underwriters Certificate. '~ A fee of $25.00. Final Health Department approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. __ Final Planning Board approval. __ Final Fire Inspection from Fire Marshal. __ Final Inspection from the Building Dept. Final Landmark Preservation approval. Building Permit: 35307-Z solar panel electric system ACORD. CERTIFICATE OF LIABILITY INSURANCE oP,D ~.Rocl ="'"'"='Y~ ~.-.-7 I 01/19/09 PRODUCER THIS CERTIFICATE IS I~EQ~ A~R OF INFO~ON ONLY ~D ~NFE~ NO ~G~ U~N THE ~ATE ~cess ~eral ~, Inc. (CL) HOLDE~ ~S ~FICA~ ~ ~T ~END, ~ND ~ 365 ~OS~YS P~ D~ ~R ~E ~V~E ~FO~D BY ~E ~Q~ BELOW. ~DB~Y ~ 11797 Phone: 516-799-8222 iNSU~RS ~FO~NG CO~GE ~C ~ 425 Coun~ ~. 39A SUi~ 101 ~u,~o: Sou~ ~ton ~ 11968 eF. NERAL UAB~nY ~Ct~ OCCU~ENCE $1,000,000 A X ~- COMMERCKLGEM~ALUASIUTY ~P1681L 01/31/09 01/31/10 ~'u"="'~(~) $50,000 ~~ ~[~000,000 ~E~A~E~ s 2,000,000 CERtiFICATE HOLDER TOWN OF SOUTHOLD 53095 ROUTE 25 SOUTHOLD NY 11971 TOWNSOH CANCELLAllON ACOHO 25 © ACORD CORPORA~ON 1988 STATE OF NEW YORK - WORKERS' COMPENSATION BOARD CERTIFICATE OF NYS WORKERS, COMPENSATION INSURANCE COVERAGE In-'Legal Name & Address of Insured (Use street address only)' .425 County Rood 39A, Suite I0! .' Wo coco on ofa r (onty '' en am c0 y I~_~ M c~rMM locations M Ne~ Yo~ ~ L~, a Wmp-f/p 2. Name and Address of the Entity Requesting Preof of Covernge.(Enflt~. Being Listed as the Certificate HoMer) Town 0fSouthold Building Dept. SouthoM, NY 119/1 lb. Business Telephone Number of Insured 631-7'/1-5152 lc NYS Unemployment Insurance Employer Registration Number of Insured Id. Federal Employer Identification Number of Insured or Social Security Number 20-380119 3n. Nome of Iasuranee Carrier National Union Fire lnsurnnce . 3b. Policy Nmi)er of cofity listed in box WC009924195 3e. Policy effective period 3d. The Pr~prietor, Partners or ExecuGve Offieers are [] included. (ou~ cheek box if all imrtn~toflicers intruded) ~] all excluded or cerinin lmrtners/offieers excluded. This certifies that the insurance carrier indk~al abov~ in box "3" insures the business mfevmced above in box "la" for worke~' compcosation under lbo New York $1at~ Work. s' Compensation Law. (To asa this form, New York (NY) mast bo listed under lm 3A on the INFORMATION PAGE of the workers' compeasation iasurnnce policy). T~e Insurnnco C~xier or its liccosed ag~t wlil send The lnstwance Carrier will also notify the above certificate holder within 10 day~ IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than mmlmymo~ of premiums that cancel the policy or eliminate the inmred from the tI~s f~m ~s ap~r~ved by tke ~mmam~e ~arr~er ~r ~s~`~m~ ag~m~ or m~dl th~ P~I~y ~r~km ~--~ I~get~ M b~x ``3~whl~ever ls Please Note:. Upon ~ eaneelinflon of the worimrs' eompeasation polK'y indicated on this form, ff the business continues to be named on a permit~ license or contract issued by a cordfi~e holder, the business mast provide that cerflflcote homer with a new Cerlificote of Workms' Compensation Coverage or other author;mi proof tbot the business is complying with the mandatory coverage requirements of the New York State Workers' Compensation Law. Under pennlty of perjury, I certify that I am an authorized reprsecoindve or firensed agent of the insurnnco carrier referenced above and that the ~amed insured has the coverage as depicted on thb foreL Z~oproved by:. Approved by:. 'l'non~q P. Terry (lMat r,m~ of aa~ri~d m~mamti~ or #cmmxl a~m of/m~.~ cartier) (Oa~) Telephone Number of authorized represcolatlve or licensed agent of insunmce carriec __631-283-8000 Please NoM: Only ~uran~ carriers and their licensed ago~ ar~ mahorRed to issue Form C-105.2. Insurance brokers are NOT mahorized to issue it. C-105.2 (9-.07) www.wcb.state.ny.us Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED:, 12/10/2007 No. 43858-ME SUFFOLK COUNTY Master Electrician License This is to certify that ROBERT J SK'YPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, rules and regulations of , ~. the County of Suffolk, State of New York. ~~ ~ Additional l~ualnesses ' NO'[ VALID wITHouT ' DEPARTMENTAL SEAL AND A' CURRENT CONSUMER AFFAIRS ~ ID C,~d) Director SPR-215-WHT 215 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE The SunPower 215 Solar Panel provides industry leading efficiency and performance. Utilizing 72 next generation SunPower all-back contact solar cells and an optimized panel design, the SunPower 215 delivers an unprecedented total panel conversion efficiency of 17.3%. The 215 panel's reduced voltage-temperature coefficient and exceptional Iow-light performance attributes provide far higher energy delivery per peak power than conventional panels. SunPower's High Efficiency Advantage - Up to Twice the Power Thin Film Conventional Wa~s / Panel 65 165 Etficiency 9.0% 12.0% kWs 90 120 215 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE Peak Power (+/-5%) Prnc:< 215 W Rated Voltage Vmp 39.8 V Rated Current imp 5.~40 ~A ..... Open Circuit Vohage Voc 48.3 V Shor~ Circuit Current Isc 5.80 A Maximum System Vohage IEC, UL 1000 V, 600 V Temperature Coefficients Power ~).38%/°C Series Fu~ R~ng 15 A P~k Po~ ~r Unit Ar~ 173 W/m~, 16.1 W/~ C~ ~C Rating 198.5 W Solar Cells 72 SunPower alLback contact mon~cryslalline Front Glass 3.2mm (1/8 in.) tempered Junction Box lpg5 rated with 3 bypass diodes Output Cables 900mm le~g~ cable / Mulli,Conlacl connectors Frame Anodized aluminum alloy type 6063 V~.ight 15kg, 33lbs 7.0 6.0 5.0 t0e0W/,~ ~ 4.0 80OW/m~ ~ 1.0 ~ ~ 0.0 0 I0 ~ ~ ~ ~ Max load 50 psf J2400 Pascals) front and back Impact Resistance Hail- 25mm (1 in) at 23 m/s {52 mph) E) CAUTION: READ SAFETY AND INSTALLATION INSTRUC11ONS BEFORE USING THE PRODUCT. Go to www sunpowercorp corn/panels for detaiis SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high-efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly mare energy than competing systems. ~ Printed on recycled paper www. sunpowercorp.com 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE The SunPower inverters 3000m and 4000m provide exceptional reliability combined with superior performance. Innovative design and advanced testing have been brought together to create a durable inverter that enables optimal system performance over the long term. Both models come with a standard 1 O-year warranty. SPR-3OOOm and SPR-4OOOm wv~v. su npowercorp,com 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE SPR-3OOOm SPR-4OOOm 3500 W @ 208 V / AC Power 3ooow 40CO W ~ 240 V Current (@ 208V, 240V) AC Nominal Vehage / Range 183 -229V @ 20~ VAC 183 -229V~208 VAC 2It -264V e 2~ov~: 211-26~ve240 VAC AC Frequ4HIc~ / RcIIIge 60 Hz / 59.3 Hz- 60 Hz / 59.3 Hz- 60.5 Hz 60.5 Hz Power Factor ] ] Peak Inverter Efficiency 96,6% 96,8% CEC Weigl~d Efficie~7 9,~.0 % e ~os v 95,5 %e 20ay 95.5 % @240V 96,0%Q 240V Recommended Array Input 36oo w 48oow ~w~r ~ e src) D~ Input Vohoge Range 200-500 V e 20sv 250-600v e 206 VAC 200-500 V Q 240v 250-600 V Q 240 VAC Peak Power Trocking V~nge DC Max. Input Current IX: Vohage Ripple No. ~ Fused Siring Inpuls 4 Power Consumplion: Standby / Nigh.lme Fused DC Disconned Grounding eosie... Ground SPRm Efficiency Curves ~ so 75 % d Ratnd Output Power SO% 9O% 100% Shipping Dimensions W x H x D inches 23.5' x 18.5" x 16.0' Unit Dimensiom W x H x D inches 17.8' x 13.8' x 9.3' Immder Weight e8 lb, Shipping Weight 94 lbs Enclosure NEMA 3R Ambient Tempemlum Range -13 to +l 13 °F SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our higbefflciency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. www. sunpowercorp.com 2 Strings of 9 SunPower 215 watt panels. Each sting has 1,935 watts Array total of 3,870 watts All panels to be grounded as per NEC code 30 AMP two pole DC ~ switch from panels to ~ { inverter I ~_ ] 30 AMP 3R 240 VAC switch near 240 VAC from inverter to a 30 SUNPOWER SPR 4000 INVERTER 2 Strings of 7 SunPower 215 W panels, Each string 1,505 watts Array total of 3,010 Watts AIIpanelstobe grounded asper NEC c~3de 2, 30 AMP two pole DC switches from panels to inve~r SUNPOWER SPR 3000m INVERTER 240 VAC 240 VAC from inverter to a 30 Amp switch near utility me~r 2 Strings of 7 SunPower 215 W panels, Each string 1,505 watts An'ay total of 3,010 Watts All panels to be grounded as per NEC code 2, 30 AMP two pole DC switches from panels to inverter SUNPOWER SPR 3000m INVERTER 240 VAC 1 240 VAC from inverter to a 30 Amp switch near utility metor Paciflco Engineering PC PO Box 1448 Sayville, NY 11782 www pac~flcoengineering.com December 18, 2009 Town of Southold t:~u~lding Department 54375 Route 25, P.O Box 1179 Southold, NY 11971 Subject Solar Energy Installation for Joe Cowley 630 Oriole Dr Southold. NY 11971 Engineenng Consulting Ph 631-988-0000 Fax 631-382-8236 engineer@pacificoengineer~ng com ALL CC ,3 I have reviewed the roofing structu~l';aLth~ subject add¢~.~he structure ~,g~p~,~, t,_he ~ hpnatwe, jgt3~'~L~ FOR the roof mounted system The umts are to ~r.(~l~d in accordance w th thl~f~ur~,~n~, ,1~1~'~,~o~,i ~, ,~ORS instructions. I have determined that the installation will meet the requirements of the 2007 N~S 'l~L~ldmg'Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions Roof Section A B C mean roof height 24 ft 14 ft 14 ft pitch 5 in/12 4 1/4 in/12 8 1/2 in/12 roof rafter 2x8 2x8 2x8 rafter spacing 16 in OC 16 in QC 16 in OC Reflected roof rafter span 83 ft 10 2 ft 10.1 ft Table R802 5.1(1) max 168 ft 168 ft 16.8 ft collar tie 2x6 2x6 2x6 collar tie spacing 16 in OC 16 in OC 48 in OC The climactic and load information is below: CLIMACTIC AND GEOGRAPHIC DESIGN CRITERIA Roof Section A B C Category B Wind Speed 3 sec gust, rnph 120 Ralph Pacifico, PE Professional Engineer Live load pnet30 per ASCE 7 psf 48 48 26 point pullout load, lb 252 492 137 Fastener type 5/16" dia screw, 4" length, 2 per 5/16" dia screw, 4" length, 2 per 5/16" dia screw, 4" length, 2 per GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive Southold, NY 631.765.8430 Surface 1 3.01 KW 14 SunPower 215w Panels UniRac Sunframe Azimuth = 116° Pitch = 225° Scale 3/16" = 1.0' ~,,,, ,, Pacifico Engineering PC Ralph Paci§co, PE NYS License 066182 Panel Dimension = 61.39" x 31.42" Array Length = 429.73" Array Height = 66.59" Surface Dimensions = 36'8" x 11'1" Magic # = 32.17" SunPower 230w I 2x8" Douglas Fir Rafter ;! 16" on center , · UniRac SunFrame Rail ® UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/15/2009 GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive Southold, NY 631.765.8430 Surface 1 3.01 KW 14 SunPower 215w Panels UniRac Sunframe Azimuth = 116° Pitch = 22,5° Scale 3/16" = t.0' ~,,~,, Pacifico Engineering PC Ralph Pacifico, PE NYS License 066182 Panel Dimension = 61.39" x 31.42" Array Length = 429.73" Array Height = 66.59" Surface Dimensions = 36'8" x 11'1" Magic # = 32.17" SunPower 230w ~ ! 2x8" Douglas Fir Rafter I 16" on center . UniRac SunFrame Rail ® UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/15/2009 Oi ,LOGIC GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive $outhold, NY 631.765.8430 Surface 2 3.01kW 9 Sunpower 230w Panels UniRac Sunframe Azimuth = 206° Pitch = 20° Scale 3/16" = 1.0' ?~':'~ Paciflco Engineering PC Ralph Paciflco, PE NYS License 066182 Panel Dimension = 31.42" x 61.39" Array Length = 219.94"/6284" Array Height = 126.53" Surface Dimensions = 32'3" x 12'9" Magic # = 62.14" SunPower230w 2x8" Douglas Fir Rafter 16" on center UniRac SunFrame Rail UniRac L-Foot Layout Created By: BCA Date: 12/15/2009 GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive Southold, NY 631.765.8430 Surface 2 3.01kW 9 Sunpower 230w Panels UniRac Sunframe Azimuth = 206° Pitch = 20° Scale 3/16" = 1.0' ~I,~ Pacifico Engineering PC PO ~ox 1448 Sayville, NY 11782 Ralph Pacific, o, PE NYS License 066182 Panel Dimension = 31.42" x 61.39" Array Length = 219.94" / 62.84" Array Height = 126.53" Surface Dimensions = 32'3" x 12'9" Magic # = 62.14" Layout Created By: BCA SunPower 230w 2x8" Douglas Fir Rafter 16" on center UniRac SunFrame Rail UniRac L-Foot UniRac Slider & L-Foot Date: 12/15/2009 GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive Southold, NY 631.765.8430 Surface 3 4.6kW 20 SunPower 230w Panels UniRac SolarMount Azimuth = 206° Pitch = 35° Scale 3/16" -- 1.0' Pacifico Engineering PC Ralph Pacifico, PE NYS License 066182 Panel Dimension: 61.39" x 31.42" Array Length: 245.56" Array Height: 161.1" Surface Dimensions: 22'8" x 14'7" SunPower230w 2x8" Douglas Fir RaRer 16" ~ on center , , UniRac Solar Mount Rail ~) UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/15/2009 GreenLogic, LLC Proposed Joe Cowley 630 Oriole Drive Southold, NY 631.765,8430 Surface 3 4.6kW 20 SunPower 230w Panels UniRac SolarMount Azimuth = 206° Pitch = 35° Scale 3/16"= 1.0' ;~:. Pacifico En~ineerina PC PO Box 1448, Sayville, NY 11782 Ralph Pacific. o, PE NYS License 066182 Panel Dimension = 61.39" x 31,42" Array Length = 245.56" Array Height = 161.1" Surface Dimensions = 22'8" x 14'7" SunPower 230w ,) 2x8" Douglas Fir Rafter ; 16" on center · . UniRac Solar Mount Rail e UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/15/2009 SF-.CI'iON 55 BLOC~ 6 LOT 15.008 COONTY OF SUFFOLK TOWN OF SOUTI~LD STATI~ Oi; ]q~,V YORK..