Loading...
HomeMy WebLinkAboutTR-7300AJill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 0555C Date July 19, 2010 THIS CERTIFIES that the roof mounted photovoltaic system and domestic hot water solar system At 1340 Cedar Point Drive East, Southold Suffolk County Tax Map #92-1-5 Conforms to the application for a Trustees Permit heretofore filed in this office dated 4/28/10 pursuant to which Trustees Wetland Permit #7300A dated 5/19/10 was issued and conforms to all of the requirements and Conditions of the applicable provisions of law. The project for which this certificate is being issued is for a roof mounted photovoltaic system and domestic hot water solar system. The certificate is issued to BARBARA MAY & JACK MAY owners of the aforesaid property. Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD DATE OF INSPECTION: Ch. 275 Ch. 111 INSPECTION SCHEDULE __ Pre-construction, hay bale line/silt boom/silt curtain 1 st day of construction % constructed _~ Project complete, ~mplia~inspection. INSPECTED BY: ~ COMMENTS: CERTIFICATE OF COMPLIANCE: Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall, 53095 Main Rd. P.O. Box I 179 Southold, NY 11971 Telephone (63 t ) 765 - 1892 Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD YOU ARE REQUIRED TO CONTACT THE OFFICE OF THE BOARD OF TRUSTEES 72 HOURS PRIOR TO COMMENCEMENT OF THE WORK, TO MAKE AN APPOINTMENT FOR A PRE-CONSTRUCTION INSPECTION. FAILURE TO DO SO SHALL BE CONSIDERED A VIOLATION AND POSSIBLE REVOCATION OF THE PERMIT. INSPECTION SCHEDULE __ Pre-construction, hay bale line __ 1st day of construction ¼ constructed Project complete, compliance inspection. Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Brederneyer Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1892 Fax (631) 765-6641 BOARD OFTOWNTRUSTEES TOWN OFSOUTHOLD Permit No.: 7300A Date of Receipt of Application: April 28, 2010 Applicant: Barbara May & Jack May SCTM#: 92-1-5 Project Location: 1340 Cedar Point Drive, East, Southold Date of Resolution/Issuance: May 19, 2010 Date of Expiration: May 19, 2012 Reviewed by: Trustee Bob Ghosio, Jr. Project Description: To install roof mounted (close to roof) photovoltaic system and domestic hot water solar system. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the site plan prepared by Ralph Pacifico, PE, received on April 28, 2010, and stamped approved on May 19, 2010. Special Conditions: None. Inspections: Final inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. I~M. Dohert~nt Board of Trustees JMD:eac Jill M. Doherty, President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr. John Bredemeyer Town Hall, 53095 Main Rd. P.O. Box I 179 Southold, NY 11971 Telephone (63 I) 765-1892 Fax (631) 7654641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Please be advised that your application dated ,~¢':/ o~ c~::) z o has been reviewed by this Board at the regular meeting of ~q~/ /(~. ,-,,,qo/c) and your application has been approved pending the completl6n of the following items checked off below. __ Revised Plans for proposed project __ Pre-Construction Hay Bale Line Inspection Fee ($50.00 __ Ist Day of Construction ($50.00) __ ½ Constructed ($50.00) I///'Final Inspection Fee ($50.00) __ Dock Fees ($3.00 per sq. ft.) Permit fees are now due. Please make check or money order payable to Town of Southold. The fee is computed below according to the sChedule of rates as set forth in Chapter 275 of the Southold Town Code. The following fee must be paid within 90 days or re-application fees will be necessary. You will receive your permit upon completion of the above. COMPUTATION OF PERMIT FEES: TOTAL FEES DUE: BY: Jill M. Doherty, President Board of Trustees Jill M. Doherty. President James F. King, Vice-President Dave Bergen Bob Ghosio, Jr John Bredemeyer P.O. Box 1179 Southold. NY 11971 Telephone (631 ) 765-1892 Fax (631 ) 765-6641 Southold Town Board of Trustees Field Inspection/VVorksession Report Date/Time: GreenLogic, LLC on behalf of BARBARA MAY & JACK MAY requests an Administrative Permit to install roof mounted (close to roof) photovoltaic system and domestic hot water solar system. Located: 1340 Cedar Point Dr. East, Southold. SCTM#92-1-5 Type of area to be impacted: __Saltwater Wetland Freshwater Wetland Sound Bay Distance of proposed work to edge of wetland Part of Town Code proposed work falls under: __Chapt.275 Chapt. 111 other Type of Application: __ Wetland __Coastal Erosion __Amendment ._Administrative__Emergency Pre-Submission __Violation Info needed: Modifications: Conditions: Present Were: __&King __J.Doherty __J. Bredemeyer "~ B.Ghosio, __ D. Dzenkowski __other Form filled out in the field by r~o/~ Mailed/Faxed to: Date: D. Bergen__ 215 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE The SunPower 215 Solar Panel provides indush'y leading efficiency and performance. Utilizing 72 next generation SunPower all-bock contact solar cells and an optimized panel design, the SunPower 215 delivers an unprecedented total panel conversion efficiency of 17.3%. The 215 panel's reduced voltage-temperature coefficient and exceptional Iow-light performance attributes provide far higher energy delivery per peak power than conventional panels. SunPower's High E~ciency Advantage - Up to Twice Ihe Power Thin Film Convenllonal ~m~mmmi~~f' Watts / Panel 65 165 Efficiency 9.0% 12.0% ~~ kWs 90 120 SPR-215-WHT ~',~} C i~ c(~i~ 215 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE Peak Power [+/-5%) Pmax 215 W Rated Voltage Vmp 39.8 V Rat~ Current Imp 5.40 A Ooen Circuit Voltage Voc 48.3 V Short Circuit Current ISC 5.80 A Maximum System Vollage IEC, UL 1000 V, 600 V Tem~enalure Ccefficienls Series Fuse Rating Peak Power per Unit Area CEC PTC Rating Power -0.38%/°C Voltage (Voc) -136.8 mV/°C Current (Isc) 3.5 mA/~C 15A 198,5 W IV Cm'~e 7.0 6.0 5.0 4.0 2.0 1.0 0.0 0 10 20 30 40 Temperature - 40° C to +85° C {~40° F to +185° F) Max load 50 psf (2400 Pascals) front and back Impact Resistance Hail - 25mm (1 in) at 23 m/s (52 mph) 10year lirnil~d p~aduct warran¥ CAUT1ON: READ SAFETY AND INSTALLATION INS1RUCTIONS BEFORE USING THE PRODUCT. Go to www. sunpowercorp.com/panels for details SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high-efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significan~ ¥ more energy man competing systems. ~e~ Prinled on recycled paper ~vw.su n powercorp,com 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE The SunPower inverters 3000m and 4000m provide exceptional rdiability combined with superior performance. Innovative design and advanced testing have been brought together to create a durable inverter that enables optimal system performance aver the long term. Both models come with a standard 1 O-year warranty. SPR-3OOOm and SPR-4OOOm www. sunpowercorp.com 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE SPR-3OOOm SPR-4OOOm AC Power 3000W 35C0 W ~' 208 V / 4C~O W {I 240 V AC Maximum Output Current 1 SA, 12.5A (~ 208V, 240V) AC Nominal Vohage / Range 183 - 229 V~'208 VAC 183 - 229 V e 20~ VAC 211 264Ve240VAC 211-264Ve240VAC "~ -)'C---uen-' / m~t~e-n-- 60 Hz / 59.3 Hz - 60 Hz / 59 3 Hz - AC 60.5 Hz 60.5 Hz P~ Factor 1 1 Peak Inverter E~ciency 96.6% 96.8% CEC Weighted Efficiency 95.0 % J* 208 V 95.5%e208V 95,5 %O 240 V 96.0 % ~* 240 V Recommended Array Input Power (DC a, STC) DC Input Voltage Range 3600 W 4800 W SPRm Efficiency Curves 100 aao wk 80 75 7O 0% to~ 20% ~o% 40% s0% 6o% 70% 80% ~ ~o~ % of Rated Oulput Power Shipping Dimensions W x H x D inches 23.5' x 185' x 16.0" Unit Dimensions W x H x D inches 17.8' x 13.8" x 93' Inverter Weight 88 lbs Shipping Weight 94 lbs Cooling Forced Air / Sealed El~:tronics Enclosure Enclosure NEt~, 3R Mounting Wall Mount Bracket Standard Ambient Temperatere Range -I 3 to + 113 °F Peak Power Tracking Vohage DC Ma~ Input Current DC Voltage RippJe No. of Fused Sh'ing Inputs Power Cansumption: Stendby / Nighfllme 17A 18A Certifications <8% Fused DC Disconnect Standard: Complies w NEC Standards GrouIIdiog Positive Ground SunPower designs, manufactures and delivers higl>performance solar electric technology worldwide. Our high-efficiency solar cells generate up h3.50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and lrackers deliver significantly more energy than competing systems. www. sunpowercorp.com 1 String of 10 Sunpower 215 watt panels. Each sting has 2150 watts Array total of 2150 watts All panels to be grounded as per NEC code 30 AMP two pole DC sw~tch fi'om panels to inverter Sunpower 4000 Inverter 240 VAC 30 AMP 3R switch near utility meter 240 VAC from inverter to a 30 VELUX solar water heating system with electric back-up System models: CLI U12 SKOL218 CLI U12 SKOL318 CLI U12 SKOW218 CLI U12 SKOW318 Cold water Hot water Heatedglycol Cooled glycol 1. Collectors 2. Flashing 3. Connector tube 4. Flextubes 5. Air Separator 6. Pump station/controller 7. Expansion tank 8. Solar storage tank 9. Mixing valve 10. Temperature sensor 11, Electric auxiliary with thermostat Notes: l. This drawing is manot ta show a system piping concept only. The Irc'taller Is responsible for all equlpmant and detailing bY local codes. 2. Anti-freeze, non- potable heat transfer fluid shall be used for the solar storage tank hsot exchanger clrcult anlY- Never irrtreduce Antl'~e ~latlan to any other solar storage tank connection other than the so!ar heat exchanger. 3. If~here Is acheckvalveonthe cold water feed Ilne, athermal expansion tank suitable for potable watar must be sized and installed within this piping system between the cbeck valve and the cold water Inlet of the solar storage tank~ 4. The a~ anti-scald mixing valve provided must always belnstalled as shown. 5. For all electric beck-up models, make sure solar storage tank Is fully purged of air before power Is turned an to the back'up heat source. VELUXsolarwaterheatlngsystemwithelectrlcback-up - Part3:Solarwaterheatersysteminstallaflon - 7 VELUX solar water heating system with boiler back-up System models: CLI U12 SKOL219 CLI U12 SKOL319 CLI U12 SKOW219 CLI U12 SKOW319 Cold water Hot water Heated glycol Cooled glycol 1. Collectors 2. Flashing 3. Connector tube 4. Flextubes 5. Air Separator 6. Pump station/controller 7. Expansion tank 8. Solar storage tank 9, Mixing valve 10. Temperature sensor 11. Auxiliary heat exchanger 12. Backup heat source provided by another Installation Notes: 1. This drawing Is meant to show a system plpin~ concept only. The Installer Is responsible for all equipment and de~ll~ ~ local ~ 2. Anti-freeze, nco- potable heat transfer fluid shell be used fo~ the solar storage tank heat exchanger c~lt only. N~r I~ce ~t~e sol.on ~ any other solar storage tank connection other than the solar heat exchanger. 3. ff thera is a check valve on the cold water feed line, a thermal expamlon tank suitable for potalde water must be sized and i~ ~ln this ~ping sys~m between the check valve and the cold water Inlet of the solar water heater. 4, The an anti-scald mixing valve provided must always be Installed as shown. 5. Circulators shown in the hydronic boiler piping above should have an Integral flow check or alternately use a stock pump with an external spdng type check valve. (Circulators with integral flow checks are not to be used in solar systems due to extreme temperatures~ 8 - Part 3: Solar water heater system Installation - VELUX solar water heating system with boiler back-up VELUX solar pre-heat water heating system System models: CLI U12 SKOL218 CLI U12 SKOL318 CLI U12 SKOW218 CLI U12 SKOW318 Cold water Hot water Cooled glycol 1. Collectors 2. Flashing 3. Connector tube 4. Flextubes 5. Air Separator 6. Pump station/controller 7. Expansion tank 8. Solar storage tank 9. Mixing valve 10. Temperature sensor 11. Existing gas or electric water heating 12. Solar system bypass valves Notes: 1. This drawing is meant to show a system piping concept only. The installer is responsible for all equipment and detailing by local codes, 2. Anti-freeze, non- potable heat transfer fluid shall be used for the solar storage tank heat exchanger circuit only. Never Introduce Anti-freeze solution to any other solar storage tank connection ether than the solar heat exchanger. 3. If there Is a check valve on the cold water f~-°d line. a thermal expanslon tank suItable f°r p°table water must be sized and installed wRhln this piping systm between the check valve and the cold water Inlet of the solar storage tank. 4. The an anti-scald mixing valve provided must always be Installed as shown. 5. For all electric hack-up models, make sure solar sterage tank Is fully purged of air betore power Is turned an te the back-up heat s°urce. VELUX solar pre-heat water heating system - Part 3: Solar water heater system Installation - 9 Collector I,o~ion on 16" o.c. rafters CLI U12 4000 · 2 Collector layout · 16" o.c. rafters -- 10"x5" hole 5"x5" hole 5"x5" hole-~l 4'-6 3/4' 4'-6 3/4" CLI U12 4000 · 3 Collector layout · 16" o.c. rafters 5"X5" hole --10"x5" hole-- 5"x5" hole-- Il ii ii II 4'-6 3/4" 4'-6 3/4" 4'-6 3/4" 14 - Part 3: Solar water heater system Installation Collector location on 16" o.c. rafters Collector location on 24" o.c. rafters CLI U12 4000 · 2 Collector layout · 24" o.c. rafters -- t O"xS" hole ~5"xS"hole ,g 5"x5" hole ~[ 4'.6 3/4" 4'-6 3/4" CLI U12 4000 · 3 Collector layout · 24" o.c. rafters 5"x5" hole --10"x5" hole,[ 5"x5" hole --il I 4'-6 3/4" 4'-8 3/4" 4'-6 3/4" Collectorlocatlonon24"o.c. rafters- Part3:Solarwaterheatersysteminstallation - 15 VELUX solar collector J F W .T° Gross 32.0 Frame 30.7 Glass 29.4 53.5 Aperture 27.4 51.6 Absorber 2Z8 51,9 Packaging 34.0 57.4 Weight (lbs.) Collector weight 130 73 57 Weight w/fluid 141 79 64 Gross area 27.1 15.2 12.5 Collector area (sq. ft.) Aperture area 23.1 12.4 9.8 Absorber area 23.4 12.6 10.0 Fluid volume (gal.) 0.58 0.34 0.24 Max operaUng pressure (psi) 87 87 87 Test pressure (psi) 145 145 145 Stagnation temperature (°F) 374 374 365 Clear day 29 15 12 Thermal performance rating- warm climate (lO00s btu/day) Mildly cloudy day 20 11 8 Cloudy day 11 6 5 Clearday 19 10 8 Thermal performance rating- cool climate (lO00s btu/day) Mildly cloudy day 11 6 4 Cloudy day 4 2 1 eta0 (start efficiency) 0.6960 O.6610 0.6390 Efficiency al(Btu/hr*ft2*°F) 0.4747 0.4666 0.4603 a2 (Btu/hr*ft2*°F2) 0.0020 0.0019 0.0018 32 - Part 5: Specifications - VELUX solar collector VELUX flextubes and connections Max operating pressure (psi) 100 External diameter, pipe (mm) 21,8 Internal diameter, pipe (mm) 16.3 External diameter, Insulation (mm) 47.8 Liquid volume, (L/m) 0.24 Material, pipe Stainless steel / AIS1316 TI Material, Insulation Foam EPDM Temperature limE, insulation (deg F) + 350 to- 40 F Insulation value (w/mK) 0.04 VELUXflextubesandconnectlons - Part 5: Speclficatlons - 33 VELUX glass lined solar storage tank (with electric back-up) C o~Det Electric Element Surface mounted sdar sensor Enamel lined tank with flow coat technology Solar powered enamel flow coat technology Temperature and pressure relief valve lacket insulation MODEL # GAL Dimensions A B C D E F TFF080 0204US 80 23" 71V!', 60]/~- 8]/4" 8- 273/~- TFF120 0204US 119 27" 64- 51V4- 11. lO,A- 213/," MODEL# GAL Heat exchanger outlet size Inlet / outlet size Shipping weight (lbs) TFF 080 0204US 80 1" 1IA" NPT 237 TFF 120 0204US ].19 1" 1%" NPT 336 Recovery of back up MODEL # Solar HX volume gallons Heated water volume of In minutes First draw* backup 65° rise 90~ rise 65* rise 90" rise TFF 080 0204US 1.5 gal 37 gal 78 mln 108 mln 38 gal 26 gal TFF ]2.0 0204US 1.$ gaJ 67gal 14~. rnln 196 mln 70gal 46gal * AMOUNT OF WATER DRAWN OUT OF STORAGE TANK WITHOUT ANY ENERGY INPUT VELUX reserves the right to make product changes or updates without notice. VELUX will not be held liable for typographical errors In literature. For questions, please consult the factory. 34 - Part 5: Specifications - VELUX glass lined solar storage tank (with electric back-up) VELUX glass line olar storage tank (with bac heat exchanger) E "* A ' HO 'outlet ~lle~ back-up ena~nel heat exchang~ Temperature and with flow codt pressure relief valve technology Boiler t Surface mounted solar seflsor Enamel lined tank with flee foam flow coat t~chnolm3y Inflation Solar powered enamel heat exchang~ flow coat technology Dimensions MODEL # GAL A B C D E F G H TFF 0801204US 80 23" 71]/'-" 601A" 81A'' 8" 34" 43" 55V-," TFF 1201204US 119 27" 64" 51'/," 11" 10~/," 28" 36" 47" MODEL # GAL Heat exchanger outlet size Inlet / outlet size Shipping weight (lbs) TFF0801204US 80 i"NPT 1]/_," NPT 286 TFF 120 ]204US 119 1" NPT 1]/~" NPT 367 Recovery of hack up HX volume gallons Heated water volume in minutes Boiler output for test First draw* MODEL # of back up recovery Solar Boiler 65°dse I 90~rlse 65°dse 90*dse TFF 0801204US 2 gal l gal 37 gal 17 rain ! 24 min 90,000 BTU/HR 38 gal 26 gal TFF1201204US 2gal 1gal 67gal 22min I 31mln IO0,O00BTU/HR 70gal 46gal * AMOUNT OF WATER DRAWN OUT OF STORAGE TANK WITHOUT ANY ENERGY iNPUT VELUX reserves the fight to make product changes or updates without notice. VELUX will not be held liable for typographical errors in literature. For questions, please consult the factory. VELUXglassllnedsolarstoragetank(wlthback-uphaatexchanger) - Part 5: Speclficaflons - 35 CERTIF ATE 0F LIABILITY INSU t. NCE PRODUCER ' THIS C~<HFICATE IS ISSUED AS A MATTER OF INFORMATION ;. ~ ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Brookhaven Agency, Inc. ~ HOLDER. THiS CERTIFICATE DOES NOT AMEND, EXTEND OR P.O. BOX 850 i ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. 150 Main Street SL h .:!L INSURERS AFFORDING COVERAGE NAIC # East Setauket NY 11733 " iNSURED Greenlogic, LLCL ......... r; ,I { !'~!~;,~;__~__ INSURERA: NGM INSURANCE COMPANY 425 County Road 39A Suite 101 ~NSURERB: MERCHANTS PREFERRED INS CO Southampton NY 11968 INSURER C: ~VERAGES THE POLICIES O FINSU RAN CE LISTED BELOW HAVE BEEN I SSU ED T OTHEINSURED NAMED ABOVE FOR THE POLICY PERI ODIN D I CAT ED. N OTWITH S TAN DING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY SE ISSUED OR MAY PERTAIN, THE INSURANCEAFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECTTOALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLJUMS. GENERAL LIABILITY EACH OCCURRENCE $1 ~000~000 A X X COMMERCIALGENERALLIABILITY MPP1681L 01131110 01131111 DAMAGE TO RENTED I CLAIMSMADE [] OCCUR MEDEXP{Anyoneperson) $ 5,000 X XCU PERSONAL & ADV INJURY ~; 11000,0(30 ~' CONTRACTUAL LIAB GENERAL ^GGREOATE $ 2,000,000 GEN'LAGGREGATELIMITAPPLIESPER: PRODUCTS-COMP/OPAGG $ 1~000,000 AU~TOMOBILE UABILITY COMBINED SINGLE LIMIT $ 1 ~000,000 B A ~X ANYAUTO CAPI043565 06112/2009 06112/2010 (EaaCC~dent) EXCESS I UMBRELLA LIABILITY EACH OCCURRENCE $ 2,00010oo A X ~ OCCUR [] CL~IMSMADE CUP1681L 01131110 01131111 A~GRE~TE ; 2,000,000 RETENTION $ 10,000 $ wO..ERE COMPBN~O" I .......... I IO;."' CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 Phone: I Fax: ACORD 25 (2009/01) SHOULD ANY OF THE ABOVE DESCRIBED POUCIEB BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL ~0 DAYS WRITrEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO OO SO SHALL IMPOSE NO OOUGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES* AUTHORIZEDREPREi:Nii:~:{~D ~CORI~ATION. All I'lg:P:::ed. The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK - WORKERS' COMPENSATION BOAR~ CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1~ Legal Name & Address of'Insured (Use street address only) .425. County Rood 39A, SoRe 101 . SoUthampton, NY 11968 WorkLoeatiou ofl~sured (O~y reqm~dgco~o~ge is spec~c~//y lim_a~ W cardin locat~ous ~n Ne~ York ~ L~, a Pot~) '. 2. Name and Address of the Entity RequeSting Proof of Coverage.(~ntity Being Listed ns the Cerfiflente Holder) Town Of $outhoM Budding Dept. ~ Route 25 Soathold, NY 11971 lb. Business Telephone Number of Insured 631-77I-$152 le. NYS Unemployment Insurnnce EmPloyer Registration: Number of Insured ld. Federal Employer Identifleafion Number of Insured or Soeial ~ecuHty Number 20-3~0119 3a. Name of Insurance Carrier National Union Fire Insurnnce 3b. Policy Number of entry listed in box "la" WC~09924195 ~ Policy effective period ' 08/11/2009 to 08/IlR0JO 3d. The Proprietor, Partners or Executive Off-w. ers are ~] included. (only eheek ~x if all par~ez~/oW~eers ineluded) O aH excluded or certoin imrtners/officers excluded. This cetfi~es that the insmnnce carrier indicated above in box ~3" insures the business ref¢,enced above in box "la" for workers' compensation under tbe New York Stal~ Workers' Compensation Law. (To nsc this form, New York (NY) mnst be listed onder Item 3A on the INi~RMA'iION PAGE of the workers' cempensa~on losurnnce pelk-y). The lnsm~uce Carrier or i~s licensed ngem will send this Certificate of Instmmce to lhe envy listed above as lhe certificate holder in box "2". The Insurance Carrier will also notify the above co~ificate holder within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 da~s IF there are reasons other ttgm nonpayment of pr~nhans that cancel the policy or eliminate the insared from the coverage indicated on this Ce. rtificat& (]~-~e nofic~ m~/ be so~t by regular maiL) Otiteanvise, tkis CetKf'wwle is valid for one year after ~is farm is approped by tke hmoxmce ~arrier or Hs licotsed oge~ or tm~H tke policy e~q~hw/~on ~_~,, Hs~_d ht box ~3c~, wh~ckeper is Please Note: Upon the eancellotion of the workers' eompemmtion policy indiented on this form, il'the business continues to be named on a pemR, license or eontraet issued by a certificate homer, the business must provide that certRicete homer with a new Certificate of Workers' ~ompemnfion Coverage or other authorized proof that the business is complying with the mandatory eovernge requirements of the New York State Workers' Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance cerfier referenced above and that the named insured has the cevernge ns depicted on this form. App,uved by: Thomas P. Tert~. (Print nan~ of authorized repze~mml~o of Ik:ensed sgmt of immance ~u, ~r) (s~) '.-o (i~) T~e: Amhorized ~ Telephone Nnsaber of auflmm~z~i ~c. la ~sentafive or licensed agent of insmm,ce carrie~. __631-283-8000 Please Note: Only insurance corriers and their licensed agents are authari~ed to issue Form C-105.2. Insurance brol~rs ore NOT attthorized to issue iL C-105.2 (9-07) www.wcb.state~ny.us Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY Master Electrician License This is to certify that ROBERT J SKYPALA GREENLOGIC LLC doing business as having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, rules and regulations of the County of Suffolk, State of New York. - ' ~ Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL AND K CURRENT CONSUMER AFFAIRS ' ID CARD Director OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave.) Southold, NY 11971 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 Telephone: 631 765-1938 Fax: 631 765-3136 LOCAL WATERFRONT REVITALIZATION PROGRAM TOWN OF SOUTHOLD MEMORANDUM Jill Doherty, President To: Town of Southold Board of Truste( From: MarkTerry, Principal Planner k, LWRP Coordinator Date: May 14, 2010 Re: Proposed Wetland Permit for GREENLOGIC LLC (~G.~1 SCTM# 1000-92.-1-5 The proposed action has been reviewed to Chapter 268, Waterfront Consistency Review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to me, it is my recommendation that the proposed action is EXEMPT from LWRP review pursuant to: § 268-3. Definitions. MINOR ACTIONS item "11" which states: II. Additions to an existing building or rebuilt residential structure which results in no net increase in ground area coverage, except where the parcel is located in a coastal erosion hazard area; Cc: Lori Hulse, Assistant Town Attorney Office Use Only Coastal Erosion Permit Applicatio~ ZWetland Permit Application ~ Administrative Permit AmendmenffTransfer/Extension ece~-ved Application .~ q/O,7~//O eceived Fee:$ 5~> ~ t i/Completed Application Incomplete SEQRA Classification: Type I Type 11 Unlisted ~wordination:(date sent). RP Consistency Assessment Form e of Inspection: Receipt of CAC Report: Lead Agency Determination:__ ~uChnical Review: bile Hearing Held: ~'{ Resolution: Address [~L['O t~__.e~'C~..~v: '/)O,~'JF ,~1~ ~------~,"'1I- qr,~g:r~c.--l'D~ J Phone Number:( Suffolk County Tax Map Number: 1000 - C;] Property Location: /B4C:> Ge'c/Or /90in{- (provide LILCO Pole #, distance to cross streets, and location) (If applicable) Address: ~oard of Trustees Application GENERAL DATA Land Area (in square feet): Area Zoning: Previous use of property: ~/~" Intended use of property: (')/q~ Covenants and Restrictions: Yes fi' No If "Yes", please provide copy. Prior permits/approvals for site improvements: Agency Date __ No prior permits/approvals for site improvements. Has any permit/approval ever been revoked or suspended by · / No If yes, provide explanation: a governmental agency? Yes Project Description (use attachments if necessary): In .:~'~1 / k-c.,of r~ow,,4~ ~e/o~- I~ ~ oo~) ~o~ot~,e Board of Trustees Application WETLAND/TRUSTEE LANDS APPLICATION DATA Purpose ofthe proposed operations: l/~.~r~[I ~'~(~ Area of wetlands on lot: square feet Percent coverage of lot: % Closest distance between nearest existing structure and upland edge of wetlands: feet Closest distance between nearest proposed structure and upland edge of wetlands: feet Does the project involve excavation or filling? v/ No Yes lfyes, how much material will be excavated? How much material will be filled? Depth of which material will be removed or deposited: Proposed slope throughout the area of operations: Manner in which material will be removed or deposited: cubic yards cubic yards feet Statement of the effect, if any, on the wetlands and tidal waters of the town that may result by reason of such proposed operations (use attachments if appropriate): B~oard of Trustees Application COASTAL EROSION APPLICATION DATA Purposesofproposedactivity: Are wetlands present within 100 feet of the proposed activity? No v/ Yes Does the project involve excavation or filling? ~/' No Yes If Yes, how much material will be excavated? (cubic yards) How much material will be filled? .(cubic yards) Manner in which material will be removed or deposited: Describe the nature and extent of the environmental impacts reasonably anticipated resulting from implementation of the project as proposed. (Use attachments if necessary) 617.20 PROJECT ID NUMEER APPENDIX C STATE ENVIRONMENTAL QUALITY REVIEW SHORT ENVIRONMENTAL ASSESSMENT FORM for UNLISTED ACTIONS Only PART 1 - PROJECT INFORMATIOH ( To be completed by Applicanl or Project Sponsor) I.APPLICANTISPONSOR 12, PROJECT NAME SEQR 4. PRECISE LOCATION: Street Addess and Road Intersections. Prominent landmarks etc -or ;~rovide mae 5. IS PROPOSED ACTION: ~ New [] Expansion [] Mndiflcatio~t / alteration 7. AMOUNT OF LAND AFFECTED: Initially acres UIUmately acres 8. WILL PROPOSED ACTION COMPLY W1TH EXISTING ZONING OR OTHER RESTRICTIONS? [~es [] No I! no, das~ibe briefly: 9. WHAT iS PRESENT LAND USE ~N VICINITY OF PROJECT? (Choose as many as apply.) ~r'Resi~entlal Olndusbia, •Commercial F1Agriculture r--'lParklForestlOpenSpaoa OOther (,ese. ri.) t0. DOES AC'I'ION INVOLVE A PERMIT APPROVAL, OR FUNDING, NOW OR ULTIMATELY FROM ANY O~-IER GOVERNMENTAL AGENCY (Fede~l, State or Local) r~Yes L~No if yes, list agency name and parmil / appl'oval: 11. DOES ANY A~PECT OF THE ACTION HAVE A DU~ENTL¥ VALID PERMIT OR APPROVAL? ~]Ye$ I ~rNo If yes, list agency nalT~ and permit / approval: 1 . AS A RE LT OF PROPOSED ACTION WILL EXISTING PERMIT/ APPROVAL REQUIRE MODIFICATION? If the action Is a Cos~l Area, and you are a s~ agency, complete the Coas~l Assessment Form ~fom preceding w~ this assessment PART II -: IMPACT ASSESSMENT {To be completed by Lead Agency), A. DOES ACTION EXCEED ANY TYPE I THRESHOLO IN 6 NYCRR, PART 617A? ff yes, ~G~-~;nate the review ~_~ and uce the FULL EAF. B. WILLACTION RECEIVE COORDiNATED REVIEWAS PROVIDEDFORUNUSTEDACTIONSiN6NYCRR, PART617.67 IfNo, enegative C. CCX, IL, D ACTION RESULT IN NiY ADVERSE EFFECT8 ASSOCiaTED WITH 'R-IE F(X.LOWING: (Ai1swem may be ~, If le~) INo ' I C5. Growth, slJbsequerd devel,¥,,~tL or related ac~vt ,~es Ilke(y to be induced by Ihe IIx~pmsed actkxl? ~ bdefly: I,° I No O. ~ THE PROJECT HAVE AN IMPACT ON THE ENVIRONMENTAL CHARACl~ERISTICS THAT CAUSED THE ESTABLISHMENT OF A E 18 THERE, OR IS THERE LIKELY TO BE~ CONTROVERSY RELATED TO'POTENTI,N. ADVERSE ENVIRONMENTAL IMPACTS? If p.4~ III. o= u ,-KaliNA3mfl OF SleNFICANCE (To be oompleted ~ Agency) INST/~JO'I'IOfl8: Foeeach adverse effect idenfIfied above, determine whether it Is substantial, large, impmtantorothenV, se significant. Each effe(~ should be aSSE~ in oonnection with its (a) ee(Ung (I.e. Ul~ m- rural); (b) p,-~ Of ooountng; (i) du~; (~ ~ (e) · uffictent detail, to show that all mlevent adveme impacts have been ide~ltifled and adequatldy addressed. If quesUofl d Of part Ii was checked ~ the,detemlinatlon Ofslgnificanoe must evaluate the potenUal Impect Of the proposed Elctkm off the envfl'onmentaf dmm~tsUcs Of the CEA. WILL NOT result In any significant adverse envlroflmefltal Impacts AND provide, on sttaclxne~s as _ne~e~___~_~y, the reasons sup~ thl B~ard of Trustees Name of Lead Agency Jill M. Doherty ~:~N: ~~ad Agency President TIOe of Responsible Officer SIgn~tire of Prepare~ (If dlffere~l from res~ officer) Board of Trustees Application County of Suffolk State of New York NtiS! ~ ]~ I bl/~ re]d'- BEING DULY SWORN DEPOSES AND AFFIRMS THAT HE/SHE IS THE APPLICANT FOR THE ABOVE DESCRIBED PERMiT(S) AND THAT ALL STATEMENTS CONTAINED HEREIN ARE TRUE TO THE BEST OF HIS/HER KNOWLEDGE AND BELIEF, AND THAT ALL WORK WILL BE DONE IN THE MANNER SET FORTH IN THIS APPLICATION AND AS MAY BE APPROVED BY THE SOUTHOLD TOWN BOARD OF TRUSTEES. THE APPLICANT AGREES TO HOLD THE TOWN OF SOUTHOLD AND THE TOWN TRUSTEES HARMLESS AND FREE FROM ANY AND ALL DAMAGES AND CLAIMS ARISING UNDER OR BY VIRTUE OF SAID PERMIT(S), IF GRANTED. 1N COMPLETING THIS APPLICATION, I HEREBY AUTHORIZE THE TRUSTEES, THEIR AGENT(S) OR REPRESENTATIVES(S), TO ENTER ONTO MY PROPERTY TO INSPECT THE PREMISES IN CONJUNCTION WITH REVIEW OF THIS APPLICATION. SWORN TO BEFORE ME THIS Signature DAY OF ~, / ,20. Notary Public ~ARBARA A. CA$CIOTTA I~ Public, St.te of New yolk No. 01~8~9 ~.~ In S~otk Cou~ ~n E~ims May 11, ~ Boa~:d o£ Tx'us~.~s AUTHORIZATION (where the applicant is not the owner) (print owner of'property) (mailing adedres$) ~'r~.o~r-~ /~" dg?0,~c)~- do hereby authorize /'~/e$,'e'~ · / (Agent) to apply for permit(s) from the S°Tyd~/{ZJwner~s signat u~r )/of Town Trustees on my behalf. APPLICANT/AGENT/REPRESENTATIVE TRANSACTIONAL DISCLOSURE FORM The Town of Southold's Code of Ethics prohibits conflicts of interest on the hart of town officers and emnlovees. The nuroose of this form is to provide information which can alert the town of possible conflicts oflnterest and allow it to take whatever action is necessary to avoid same. (Last name, first name, middle initial, unless you are applying m the name of someone else or other entity, such as a company. If so, indicate the other person's or company's name.) NAME OF APPLICATION: (Check all that apply.) Tax grievance Building Variance Trustee Change of Zone Coastal Erosion Approval of plat Mooring Exemption from plat or official map Planning Other (If"Otber', name the activity.) Do you personally (or through your company, spouse, sibling, parent, or child) have a relationship with any officer or employee of the Town of Southold? "Relationship" includes by blood, marriage, or business interest. "Business interest" means a business, including a partnership, in which the town officer or employee has even a partial ownership of(or employment by) a corporation o in which the town officer or employee owns more than 5 ~ of the shares. YES NO If you answered "YES", complete the balance of this form and date and sign where indicated. Name of person employed by the Town of Southold Title or position of that person Describe the relationship between yourself (the applicanffagent/representative) and the town officer or employee. Either check the appropriate line A) through D) and/or describe in the space provided. The town officer or employee or his or her spouse, sibling, parent, or child is (check all that apply): __A) the owner of greater than 5% oftbe shares of the corporate stock of the applicant (when the applicant is a corporation); B) the legal or beneficial owner of any interest in a non-corporate entity (when the applicant is not a corporation); __.C) an officer, director, partner, or employee of the applicant; or __D) the actual applicant. DESCRIPTION OF RELATIONSHIP Form TS I Town of Southold LWRP CONSISTENCY ASSESSMENT FORM A. INSTRUCTIONS All applicants for permits* including Town of Southold agencies, shall complete this CCAF for proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This assessment is intended to supplement other information used by a Town of Southold agency in making a determination of consistency. *Except minor exempt actions including Building Permits and other ministerial permits not located within the Coastal Erosion Hazard Area. Before answering the questions in Section C, the preparer of this form should review the exempt minor action list, policies and explanations of each policy contained in the Town of Southold Local Waterfront Revitalization Program. A proposed action will be evaluated as to its significant beneficial and adverse effects upon the coastal area (which includes all of Southold Town). If any question in Section C on this form is answered "yes", then the proposed action may affect the achievement of the LWRP policy standards and conditions contained in the consistency review law. Thus, the action should be analyzed in more detail and, if necessary, modified prior to making a determination that it is consistent to the maximum extent practicable with the LWRP policy standards and conditions. If an action cannot be certified as consistent with the LWRP policy standards and conditions, it shall not be undertaken. A copy of the LWRP is available in the following places: online at the Town of Southold's website (southoldtown.northfork.net), the Board of Trustees Office, the Planning Department, all local libraries and the Town Clerk's office. B. DESCRIPTION OF SITE AND PROPOSED ACTION The Application has been submitted to (check appropriate response): TownBoard [] Planning Dept. [] Building Dept. ~ BoardofTrustees Category of Town of Southold agency action (check appropriate response): (a) Action undertaken directly by Town agency (e.g. capital construction, planning activity, agency regulation, land transaction) (b) Financial assistance (e.g. grant, loan, subsidy) (c) Permit, approval, license, certification: Nature and extent of action: Location of action: Site acreage:. Present land use: Present zoning classification: If an application for the proposed action has been filed with the Town of Southold agency, the following information shall be provided: (a) Name of applicant: ~caStnq ~r[~:~re~ C~,'~'~'rl~O::~ I C-- [C~~) (b) Mailing address: ~o3.~ O011r~'~ ~0,~-~ ~ ~ (c) Telephone number: Area Code ~b~. 3-31 - g~ ~ 9_. (d) Application number, if any: Will the action be directly undertaken, require funding, or approval by a state or federal agency? Yes ~] No ~ If yes, which state or federal agency.'? DEVELOPED COAST POLICY Policy 1. Foster a pattern of development in the Town of Southold that enhances community character, preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and minimizes adverse effects of development. See LWRP Section III - Policies; Page 2 for evaluation criteria. [] Yes [] No [~'Not Applicable Attach additional sheets if necessary Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP Section III - Policies Pages 3 through 6 for evaluation criteria ~'~ Yes [] No [~Not Applicable Attach additional sheets if necessary Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See LWRP Section III - Policies Pages 6 through 7 for evaluation criteria [-~ Yes ~ No [~Not Applicable Attach additional sheets if necessary NATURAL COAST POLICIES Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP Section III - Policies Pages 8 through 16 for evaluation criteria [-~ Yes [-~ No ~ Not Applicable Attach additional sheets if necessary Policy 5. Protect and improve water quality and supply in the Town of Southold. See LWRP Section III - Policies Pages 16 through 21 for evaluation criteria Yes ~ No I~ot Applicable Attach additional sheets if necessary Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III - Policies; Pages 22 through 32 for evaluation criteria. [-~ Yes [-~ No [~qot Applicable Attach additional sheets if necessary Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III - Policies Pages 32 through 34 for evaluation criteria. [] Yes [] No ~,~ot Applicable Attach additional sheets if necessary Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous substances and wastes. See LWRP Section III - Policies; Pages 34 through 38 for evaluation criteria. [-~ Yes ['~ No [~Not Applicable PUBLIC COAST POLICIES Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public resources of the Town of Southold. See LWRP Section III - Policies; Pages 38 through 46 for evaluation criteria. ~-~ Yes~ No ~/Not Applicable Attach additional sheets if necessary WORKING COAST POLICIES Policy 10. Protect Southold~s water-dependent uses and promote siting of new water-dependent uses in suitable locations. See LWRP Section III - Policies; Pages 47 through 56 for evaluation criteria. [] Yes [] No [~ot Applicable Attach additional sheets if necessary Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary and Town waters. See LWRP Section III - Policies; Pages 57 through 62 for evaluation criteria. Yes [] No [~Not Applicable Attach additional sheets if necessary Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III - Policies; Pages 62 through 65 for evaluation criteria. Yes [~ No [--~Not Applicable Attach additional sheets if necessary Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP Section III - Policies; Pages 65 through 68 for evaluation criteria. [-~ Yes [] No [--~Not Applicable Created on 5/25/05 ll:20AM i GREENLOGIC® ENERGY Town of Southold Town Trustees Town Hall 53095 Route 25 Southold, NY 11971 Dear Trustees: Please find attached a building permit application on behalf of Barbara Mahoney/Jack May who have engaged us to install a roof-mounted (flat to the roof) solar photovoltaic (PV) electric system and domestic hot water solar system for their home on 1340 Cedar Point Drive East, Southold, NY. In connection with this application, please find attached: · An application · A Transactional disclosure Form · AShort environmentalAssessment Form · A LWRP Consistency Assessment Form · Surveyof Premises · Engineer's Report · AOne Line Diagram · AVisio Diagram of the proposed system · Spec. sheets of the solar panels (SunPower SPR-215WHT) · Spec. sheets of the inverters (SunPower SPR4OOOm) · Spec. sheets of the hot water system (Velux) · GreenLogic Suffolk County Home Improvement License · GreenLogic Certificate of Liabilitylnsurance · GreenLogic Certificate of Worker's Compensation Insurance Coverage · Installation Manager's Master Electrician's License Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager GreenLogic LLC Gf-~EENI OGIC, LLC · w,¥w Creenl oglm oom SOUTHAMPTON/CORPORATE: 425 County Rd 39A Southampton, NY 11968 lei 631 771 5152 CUI'CHOGUE: 1070 Depot Lane Cutchogue, NY 11935 Tel: 631.765.0404 MANORVILLE: 40 Woodland Avenue Manorville NY 11949 icl: 6318300102 FIRE ISLAND: 125 Duneway Seaview, NY 11770 Tel: 631.741,6400 ROSLYN HEIGHTS: 200 S Service Rd . #108 Rosyln Heights, NY 11577 Tel: 516625 6880 Apri129,2010 Town of Southold Town Trustees Town Hall 53095 Route 25 Southold, NY 11971 Dear Trustees: Please find attached a duplicate of our the permit application on behalf of Barbara Mahoney/Jack May who have engaged us to install a roof-mounted (flat to the roof) solar photovoltaic (PV) electric system and domestic hot water solar system for their home on 1340 Cedar Point Drive East, Southold, NY. I submitted the application on Wednesday; however, there was only one copy of the package. As requested, below are duplicate items. Please find attached: An application · ATransactional disclosure Form · A Short environmentalAssessment Form · A LWRP Consistency Assessment Form · Surveyof Premises · Engineer's Report · AOne Line Diagram · A Visio Diagram of the proposed system · Spec. sheets of the solar panels {SunPower SPR-215WHT) · Spec. sheets of the inverters (SunPower SPR4000m) · Spec. sheets of the hot water system (Velux) Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager GreenLogic LLC ,R EE N[ OGI6, [ [ C · w~vw GreenLoglc SOUTHAMPTON/CORPORATE: 425 County Rd 39A Southampton. NY }1968 lei: 631.77] 5152 CUTCHOGUE: 1070 Depot Lane Cutchogue, NY 11935 ~1:631.765.0404 MANORVILLE: 40 Woodland Avenue Manorville. NY }]949 Tel: 631830 0102 FIRE ISLAND: 125 Duneway Seaview, NY 11770 Tel: 631.7416400 ROSLYN HErGHTS: 200 S. Service Rd. #108 Rosyln Heights, NY 11577 Tel: 516.625 6880 Pacifico Engineering PC PO Box 1448 Sayville, NY 11782 www.pacificoengineeringcom December 22, 2009 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 SubJect: Solar Energy Installation for May Mahoney 1340 Cedar Point Dr E Southold, NY 11971 Engineering Consulting Ph: 631-988~0000 Fax: 631-382-8236 engineer@pacificoengineering.com Roof Section A mean roof height 25 ft pitch 81/2 in/12 roof rafter 2x8 rafter spacing 16 in OC Reflected roof rafter span 9.1 ft Table R802.5.1(I) max 16.8 ff I have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the _requirements of the 2007 NYS Buildina Co e, and ASOE7~05 when installed in accordance with the menu tcturer's iA pRt::)VED BY BOARD OF TRUSTEES TOWN OF $OUTHOLD The climactic and load information is below: CLIMACTIC AND Wind GEOGRAPHIC DESIGN Category Speed, 3 CRITERIA sec gust, mph Roof Section A B 120 Live load, pnet30 per ASCE 7, Ralph Pacifico, PE Professional Engineer point pullout Fastener type psf 26 load, lb 61 Concealor #14-13 x 3" DP1 O GREENLOGIC Gr~'d.o~ic, LLC Pro~ 2 Panel Velux Domestic Hot Water Azimuth = 184° Pitch = 35° Scale 3/16" = 1.0' .~: Pacifico Engineering PC Ralph Pacific, o, PE NYS License 066182 Velux DHW Collector I I 2x8"DouglasFirRaffer 16" on center Layout Created By: BCA Date: 12/4/2009 GREENLOGIC Gi~e~ogi¢, LLC ~ 2 Panel Velux Domestic Hot Water Azimuth = 184° Pitch = 35° Scale 3/16" = 1.0' .~, Pacifico Engineering PC Ralph Paciflco, PE NYS License 066182 Velux DHW Collector 2x8" Douglas Fir Rafter 16" on center 2" self-tapping stainless · steel mounting screw Layout Created By: BCA Date: 12/4/2009 Pacifico Engineering PC PO Box 1448 Sayville, NY 11782 www.pacificoengineering.com December 22, 2009 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for May Mahoney 1340 Cedar Point Dr E Southo~d, NY 11971 Engineering Consulting Ph: 631-988-0000 Fax: 631-382-8236 engineer@pacificoengineering.com I have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2007 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A mean roof height 25 ft pitch 81/2 in/12 roof rafter 2x8 rafter spacing 16 in OC Reflected roof rafter span 9.1 ft Table R802.5.1(1) max 16.8 ff The climactic and load information is below: CLIMACTIC AND Wind GEOGRAPHIC DESIGN Category Speed, 3 CRITERIA sec gust, rnph Roof Section A B 120 Ralph Pacifico, PE Professional Engineer Live load, pnet30 per ASCE 7, psf 26 point pullout load, lb 137 Fastener type 5/16" dia screw, 3-1/2" length, 2 per LOGIC 2.15 kW 10 SunPower 215w UniRac Sunframe Azimuth = 184° Pitch = 35° Scale 3/16" = 1.0' .~bm. Pacifico Engineering PC Ralph Pacifico, PE NYS License 066182 Panel Dimension = 61.39 x 31,42" Array Length = 245.56" Array Height = 98.76" Magic# = 32.17" SunPower 215w 2x8" Douglas Fir Rafter 16" on center UniRac SunFrame Rail UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/4/2009 I GREENLOGIC 2.15 kW 10 SunPower 215w UniRac Sunframe Azimuth = 184° Pitch = 35° Scale 3/16" = 1.0' .... Pacifico Engineering PC Ralph Pacifico, PE NYS License 066182 ITIT / Panel Dimension = 61.39 x 31.42" Army Length = 245.56" Array Height = 98.76" Magic # = 32.17" SunPower 215w I J 2x8" Douglas Fir Rafter 16" on center ~-- UniRac SunFrame Rail · UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/4/2009 I (pal,~l~G R E E N LOGiC ~ogk:, LLC Propo~ 2,15 kW 10 SunPower 215w UniRac Sunframe Azimuth = 184° Pitch = 35° Scale 3/16" = 1,0' ~ Pacifico Engineering PC PO Box 1448, Sayville, NY 11782 Ralph Pacifico, PE NYS License 066182 Panel Dimension = 61.39 x 31.42" Array Length = 245.56" Array Height = 98.76" Magic # = 32.17" SunPower215w 2x8" Douglas Fir Rafter 16" on center UniRac SunFrame Rail · UniRac 4" Two Piece Flat Topped Standoff Layout Created By: BCA Date: 12/4/2009 NO .. I ' uU/- F£R JETTy N 0 EDGE OF pAVEM~N~N~NT~ LIL ZONE I I I I O-[ N T'~WATE~ UA,N OVERHEAD WIREs EX/STiNG / / I I I I I I I I SURVEY OF MARCH 3, 2009 T,OT 98 MAP OF CEDAR BEACH PARK FILE bio. 90 FILED DECEMBER 20, 1927 SITUA TED A T BAYVIEW TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK $.C. lAX No. 1000-92-01-05 SCALE 1 "=20' MAY 22, 2006 JUNE 3, 2007 ADDED SITE PLAN SEPTEMBER 16, 2008 REVISED SITE PLAN SET LATH FOR SITE INSPECTION, ADDED PROP. WATER LINE & MARCH 19, 2009 ADDED NON-TURF BUFFER dUNE t7, 2009 ADDED DRAINAGE CALCULATION OCTOBER 7, 2009 FOUNDATION LOCATION ELEV. DATUM AREA = 28,451.17 sq. ft. {TO TIE LINE) 0.65.3 ac. NOTES: 1. ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM 2. FLOOD ZONE INFORMATION TAKEN FROM: FLOOD INSURANCE RATE MAP No. 56105C0169 0 ZONE AR: BASE FLOOD ELEVATIONS DETERMINED ZONE X*: AREAS OF 500-YEAR FLOOD; AREAS OF IO0-YEAR FLOOD WITH AVERAGE DEPTH OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM IO0-YEAR FLOOD. ZONE X: AREAS DETERMINED TO BE OUTSIDE 500-YEAR FLOODPLAIN. g o~,~ 0= / / I / I TOp OF BAN TIE LINE ALONG APPARENT HIGH WATER MARK ON MAy 22, 2006 84"13'56" W N 52.13' ? l °2 0 ,p .~ 48. ~,< 20 POST ~_TEST HOLE ..7 ~ONE X* ZONE AE (EL. WALL a) TEST HOLE DATA (TEST HOLE DUG BY McDONALD GEOSCIENCE ON APRIL 17, 2006) EL 15.4' DARK BROWN SANDY LOAM BROWN CLAYEY SAND SC 123' WATER IN BROWN CLAYEY SAND SC 2£' WATER IN PALE BROWN FINE SAND SP PR~ARE~ IN ACCO~ t~ 'IHE MINIMUM ~ FOR 'OTLE ~ AS r..~u,~BLIS~IED BY lite LI..~.LS. AND APPRO~ AND ADO~iu) FOR SUCH USE BY THE NEW 'YORK Sl'A1[ LAND ~ ,ASSOCIATION. N.Y.S. LJc. No. 50467 O.8'E. ~- UNAUI~OF(IEJ~ )J.~RA'RON OR ADDITION (~ ~ WATER MARK SEC'I10N 7209 OF THE NE~ YORK STAT[ .O COPIES OF IHIS SURVEY MAP NOT BCARB4G 'IHE LAND SURVEYOR'S INKE~ SEAL OR EMBOSSED SEAL SHALL NOT BE CONS~DEREO TO BE A VALID 1RUE COPY. Ct.,~wqCARONS INDICATED HEREON ~ RUN ONLY TO 11-1E PERSON FOR WHOM THE SURVEY IS PREPA.~ AflD ON HIS BE]tN.F TO 1'dE TITLE COMP. MtY, GO--ME)ri'AL AGENCY AND LE]~DING IN:~III~N U~IP.U H~REON, .MklD 1UTION- Ce.me'ICATIONS AR[ NOT 1RANSrc.m,~LF.. THE EXISTENCE OF RIGHT OF WAYS AND/OR EASEMENTS OF RECORD. IF ANY, NOT SHOWN ARE NOT GUARANTEED. Lan d Surveyor -- Site Plans -- Construction Layout Fax (631)727-1727 P.O. Box 1931 River'head, New York 11901-0961 TrUe Su~eya -- SubdMsions PHONE (631)727-2090 OFFICES LOCAir. u AT 1856 Main Road Jameaport, New York 11947