HomeMy WebLinkAbout35305-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-34289
Date: 05/03/10
THIS u~KTIFIES that the building COVERED PORCH AJDDITION
Location of Property: 4150 ALDRICH LA
(HOUSE NO.) (STREET)
County Tax ~ap No. 473889 Section 120 Block 3
subdivision
Filed Map No. Lot NO. __
MATTITUCK
Lot 13
( HAJ~LET )
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JANUARY 18, 2010 pursuant to which
Building Permit No. 35305-Z dated JANUARY 18, 2010
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is COVERED PORCH ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR
· ~ne certificate is issued to NYLA C L~/~M
of the aforesaid building.
(OWNER)
SUF~LK CO~ DEPAI~T~T OF }{]EALTH AI~PRO~q%L
ELEt-i-KIC/%L C~ERTIFICAq~E NO.
PL~3b~ CERTIFIC_ATION I]A~q~D
N/A
N/A
N/A
hori~ed sijFhature
Rev. 1/81
Al>P
BLDG. DEPT.
lOgflq OF SOU~HOll) _
,~k.y,J~,ettJon must be tilled in by t~ewriter or
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
ink and submitted to the Building Department with the following:
A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from amhitect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
* 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Co~nmercial $15.00
Date. q' ' ~ ..3 -~' cD
(check one)
Hamlet
New Construction: ¢"
Location of Property:
House No.
Owner or Owners of Property: ]'x~ V I 04.
Suffolk County Tax Map No 1000, Section
Old or Pre-existing Building:
Subdivision
Permit No.
Street
Block
g Lot
Filed Map. Lot:
35'30 5 Date of Permit.
Applicant:
Health Dept. Approval:
Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $ ~( ~
Final Certificate:
(check one)
pplicant Signature
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 35305 Z
Date JANUARY 18, 2010
Permission is hereby granted to:
NYLA C LAMM
4150 ALDRICH LANE
LAUREL,NY 11948
for :
ADDITIONS & ALTEP, ATIONS TO AN EXISTING SINGLE FAMILY DWELLING
AS APPLIED FOR. REPLACES EXPIRED BP # 31881
at premises located at
County Tax Map No. 473889 Section 120
pursuant to application dated JANUARY
Building Inspector to expire on JULY
4150 ALDRICH LA MATTITUCK
Block 0003 Lot No. 013
18, 2010 and approved by the
18, 2011.
Fee $ 200.00
Authorized Signature
ORIGINAL
Rev. 5/8/02
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
(THIS
BUILDING PERMIT
PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 31881 Z
Date APRIL 4, 2006
Permission is hereby granted to:
NYLA C LAMM
PO BOX 455
LAUREL,NY 11948
for :
ADDITIONS AND ALTEPJkTIONS TO AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR
at premises located at 4150 ALDRICH LA
County Tax Map No. 473889 Section 120
pursuant to application dated MARCH
Building Inspector to expire on OCTOBER
Fee $ 150.00
MATTITUCK
Block 0003 Lot No. 013
31, 2006 and approved by the
4, 2007.
~r~
ORIGINAL
Rev. 5/8/02
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ] ROUGH PLBG.
I ] INS.~JL-ATION
[ ~/]~NAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INS~UL~ATION
[ ] FRAMING / STRAPPING [~FINAL
[ ] FIREPLACE&CHIMNEY [ ] FIRE SA~.,.1,/' INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
FIELD IN SPE~'~-rION I:~PORT I DATEI COM~IENTS
FO~A~ON (1S~ ,~
FOU~ATION (2~)
ROUGH ~G &
PL~G
~SULATION P~ N. Y.
STATE E~RGY CODE
. ~D~ON~ COUNTS
,60,:~00 ~
Are° ~
YOUNG & YOUNO
SURVEY FOR:
R4Y~OIVD KU~I4VI$~I 8 BAR~
tow~ ~ SOUT~D
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631 ) 765-1802
Fax (631 ) 765-951')2
BUILDING DEPARTMENT
TOWN OF SOUTI-IOLD
March 31st, 2009
NOTICE
Nyla C. Lamm
P.O. Box 455
Laurel, N.Y. 11948
RE: 4150 Aldrich Ln. (Additions/Alterations)
SeTM: # 1000-120. -3-13
Dear Ms. Lamm,
Please be advised that your Building Permit # 31881 issued April 4*h 2006 has expired.
According to the (;ode of the Town of 5outhold, a Certificate of Occupancy must be
issued before the use of the structure.
To renew your Building Permit, please submit a fee of $200.00: at that time we can
schedule an inspection by one of our Building Inspector's.
If you have any questions, please call us at 765-1802.
P, espectfully,
SOUTHOLD TOWN BUILDING DEPT
P.(). Box 117!t
Soulhold, N Y I 1 !)71-0939
Tcleph(me (631) 763-1802
Fax (631) 763-9302
BUIIJ)IN(; DIqPARTM ENT
TO~* "- - DUTHOLD
December 28th 2009
FINAL NOT ¢E
Nyla C. Lamm
P.O. Box 455
Laurel, N.Y. 11948
RE: 4150 Aldrich Lane (Abb£;.LON$/ALTERATZON$)
5CTM: # 1000-120. -3-13
To Whom It May Concern:
Please be advised that your Building Permit # 31881 issued April 4th, 2006 has expired.
According to the Code of the Town of 5outhold, a Certificate of Occupancy must be
issued before the use of the structure.
To renew your Building Permit please submit a fee of $ 200.00: at that time we can
schedule an inspection by one of our Building Inspector's.
If you have any questions, please call us at 765-1802.
P, espectfully,
50UTHOLD TOWN BU'I'LDIN~ DEPT
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www. northfork.net/Southold/
Examined ~//~//20
Approved ?/~/ ,20
/'
Disapproved aJe
Expiration ,20___
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health ~
4 sets ofBuilding Plans f
Planning Bo~proval
Survey ~
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Contact:
Mail to~:
qOo g
Building Inspector
APPLICATION FOR BUILDING PERMIT
Date ~.~-F/ffg~5~'/" y ,20 ('),5
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Buildhig Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application ~nay not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
.~hall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction ofbuildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housin.g~ode, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections. ,~_~
JA /(Signature of aPplicant or name, ifa corporation) · O~Iailing address of applicant) '
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises /t~yt/~
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No. ~96t)'7~ ~2 7-H
Plumbers LicenseNo.
Electricians LicenseNo.
Other Trade's License No.
1. Location of land on which proposed work will be done:
q7.5 0 , ?/) Lq.
House Number Street
Hamlet
County Tax Maf~..~.~10~ectmn
Subdlvts~on -~ .' ,;~,:.~ o~
Block
Filed Map No.
Lot
Lot
2. State existing use and occupancy of premises a,nd intended use and occupancy of proposed construction: a. Existing use and occupancy
b. Intended use and occupancy
3. Nature of work (check which applicable): New Building. Addition
Repair Removal
Estimated Cost j~,, ~ ·
If dwelling, number of dwelling units
If garage, number of cars
Demolition
Other Work
Fee
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front
Height Number of Stories
Rear Depth
Dimensions of same structure with alterations or additions: Front
Depth Height Number of Stories
8. Dimensions of entire new construction: Front //t Rear //z Depth
Height /o?t Number of Stories /
Rear
9. Size of lot: Front Rear _Depth
10. Date of Purchase
Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO/
13. Will lot be re-graded? YES NO /Will excess fill be removed from premises? YES NO z/
14. Names of Owner of premises/~,/t/~ ~g~P///'ff
Name of Architect
Name of Contractor .~,2'~ _r? ~¢~
Address ~//ff'F~) ,,~/_c/r',~4 &/Phone No. o9~:L 7/,~"-
Address Phone No
Address ~_~L~T/?. 6~.¥~% ,~/,~'. Phone No. ~,,~'ff"
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ,-/
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY B.~REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES
NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
COUNTY OF'"~'4 ¢fQ [4S:
t ~0/7~ ~'7/0---~ ?d/d being duly sworn, deposes and says that (s)he is the applicant
(Name of individual(~gning contract) above named,
(S)H_e is the t~ ~/"~ ~TZO/''
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to pertbrm or have performed the said work and to make and file this application;
that all statements contained in this application are trne to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this
· _~D[ day of C,-x~C, ~ 20~
Notary Public
APPR0~VED AS NOTED
DATE:.~_.~_ B.P.# '~/<~'~
NOTIFY BUILDING DEPARTMENT AT
765-1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION - TWO RSQUIRED
FOR POURED CONDRETE
2. ROUGH - FRAMING & PLUMBING
3. INSULATION
4. FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C~O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS EQUiRED AND CONDITIONS OF
/ ~ SO~TH¢'LD TOWN ZBA
-AJ ~/'J
SOUTNOLD TOWN PLANNLNG BOARD
.,/.~ ~ SOU'[HOLD TO~i'N ~'RUSTEES
f ~ N,Y.S. DEC
FLOOD DAMAGE PREVENTION
SOUTHOLD TOWN CODE.
OCCUPANCY OR
UNLAWFUL
CERTIFICATE
]Y
CERTIFICATION OF
NAILING & CONNECTIONS
REQUIRED,
I0" [:;'lA CONG. PF=DESTAL ON
2'X2'XI' ~ONC,. FTYS. OR (t~F-24) AN~.HOR
AND' FOOTIN~ FORh4 K'IITH I0" DIA TUBE
(2 PLAC.,ES)
EFL '",/ATION
I-3/4 x ~I-I/2 LVL
x 6 AC(2. POST
5GALE: I/4" = I'-0"
PINISH~-~ C. EILIN~
SHALL
I1'-0"
1= ONT L "N/ATI ON
SC'ALE: 114" : I'-O"
THE REQUIREMENTS OF THE
3TATE.
FINISHED FLOOR
n>-g
GENERAL CONSTRUCTION NOTES
1 The ~nformation on this set of construction documents is to relate basic design
intent and frammg details. They are intended as a construction aid, not a substitute
for generally accepted good btsltsng practice and compliance with current New York
state building codes The general contractor is responsible thr prowtsng standard
construction details and procedures to ensure a professionally fin~shed, strdcturally
sound, and weatherproof completed product
2 General Contractor to coordinate all sub contractors, scheduling of work, and
Jnteracbon between trades
3 The general contractor is responsible for ensudng that all work and construcbon
meets or exceeds current federal, state, and fecal codes, ortsnances and regulations,
efe These codes are fe be considered as part of the specificafions fer this building
and should be adhered to even if they are in vadance with the plan
4, Dimenmons shall take precedent over scale drawings (do not scale drawings).
5. The designer has not been engaged for construchon supervismn and assumes no
responslbdity for construction coordinating with these plans, nor responsibility for
construction means, methods, techniques, sequences, or procedures, or for safety
precautions and programs in connection with the work. There are no warranties for a
specific use expressed or implied in the use of these plans
6 Refer to floor plans, extedor tsevations, and widow schedule for types and sizes of
widows. All windows to be Andersen high performance quahty or approved equal
7. Door and widow headers to align unless othervt~se noted.
fi. General contractor IS to ensure that masonry and prefabncatad fireplace
construction meets or exceeds all manufacturer's specfflcabons and applicable codes.
9 General contractor to consult and coordinate w~th the owner and the plans for all
built m items such as bookcases, shtsving, pantry, closets, etc
10. Prowde hardw~red smoke detectors, with battery backup, on all floors and in each
bedroom, verify w~th local code reqmrements as per Section R317, New York State
Remdential Cons/ructmn Code. tsstalr carbon monoxide detectors as per code
GENERAL FOUNDATION NOTES
1 General contractor to rewew plans, elevations, and defeds to determine intended
heights of flnmhed floor(s) above typical grade.
2. All footings to rest on untssturbed sod.
3 Provide %" expansion joint mafedal between all concrete slabs and abutsng
concrete or masonry watis occurlir~g in extenor or unheated intoner areas.
4. Concrete on 4" sand or gravel fill minimum, with 6x6 - 10/10 wire mesh remforc~ng
· Intoner stabs to be placed on 6 mil. slabdized polyethylene vapor ban fei.
5. Provide crawl space ventsaflon per Iocts code requirements
6. General contractor to *nstall cop-r-rex (or copper) sheet metal term~fe shields
between air wood surfaces that are exposed to concrete or masonry surfaces.
7. Dampproof extedor of feundation with a bgummous coahng as per code and soil
conditions.
GENERAL FLOOR PLAN NOTES
1. Dimensions shall take precedent over scale drawings (do not scale drawings).
2. All mtetior walls to be covered with %" gypsum board with metal comer reinforcing.
Tape, float, and sand (3 coats)
3 Walls common to garage and house to have a layer of 5/8", fire rated gypsum board
at garage s~de with 5'-0" return on adjacent walls and ceiling. Manufactured lumber
requires 2 layers of 518", fire rated gypsum board.
4. All bath and toilet area walls and ceilings adjacent to wet areas to have water
res~stact gypsum board, or wall tile set en wonderboard or equal
DESIGN LOAD CALCULATIONS
~IINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (lbsf)
EXTERIOR BALCONIES 50
DECKS 40
ATTICS WITHOUT STORAGE 30
ATTICS WITH STORAGE 40
ROOMS (OTHER THAN SLEEPING ROOMS) 40
SLEEPING ROOMS 30
CRITERIA FOR CALCULATION OF DEAD LOAD
~ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A,I A
ARCHITECTURAL GRAPHIC STANDARDS
SNOW I
IGROUND SNOW LOAD 145lbs.
SEISMIC
IDES'GN CATEGORY IB
NIND
IE o S:. ATEGORY I?0 m,h
GENERAL FRAMING NOTES
1. AIl walls, 2x4 and 2x6, fo be stud grade or better 16" o/c AIl other frammg matedal
to be #2 douglas fir or beiter.
2. All wood frammg in contact with concrete or masonry to be pressure treafed,
3. Provide double floor joists under all walls parallel to floor jo~st span direction unless
otherwise specified
4. Provide x-bracing or sohd blocking at a maximum of fi'-0" o/c for all d~mensional
lumber floor joists.
5 Floor construction: ~" tongue and groove plywood subfloor Fimshed material to be
applied over subfloor. Glue and screw plywood decking to floor joists.
6 All window and door headers to be mmimum (2) 2x10 unless cther~se specified
All interior headers to be (2) 2x10 unless othe~ise specified.
7. Provide full solid blocking under all beanng walls
8. All beams to have adequate beadng at each end or as specified.
9, All flush beam and joist intersections to have galvamzed hangers
10 Typical ex~edor walls and roof to be sheathed with %*' exfedor grade plywood or
7/16'* eBB plywood, group 1, APA rated Plywood to span over all plates and
headers.
11. Provide insulation baffles at nave vents between rafters.
12. Exfenor flashing to be correctly installed at all connections between roofs, walls,
chimneys, projectJons, and penetrations as required by approved constr~ction
practices
13. General contractor to provide adequate attic ventdation and roof vents.
14. Provide appropriate soffit ventilation al overhangs
GENERAL PLUMBING NOTES
1 Plumbing subcontractor to be responsibts fei adhering to all applicable code and
safety requirements.
2 If wall plates or joists are cut dudng the installation of plumbing fixtures or
equipment provide bracing to tie framing back together.
GENERAL HVAC SYSTEM NOTES
1 Mechanical subcontractor is responsible for adhering ta all apphcable codes and
safety requirements
2. HVAC subcontractor to felly coordinate all system data and requirements w~th the
equipment supplier,
3 HVAC subcontractor to provide final system layout drawing and submit it to general
contractor, owner, and equipment supplier for final review and approval.
NEW CODE
GENERAL WIND PROTECTION CONNECTION NOTES
Adapted from Standard for Hurricane Resistant Residential Construction; SSTD 10-99
and 1titlE BBC High Wind Edition Wood Frame Construction
Fasteners and Connectors for Wood Frame Construction
1. A continuous Icad path between footings, foundations wails, floors, studs and roof
framing shall be prowded.
2 Approved connectors, anchors and other fastening devices not included in the
Standard Building Code, Table 2306.1 shall be installed in accordance with
manufacturer's recommendations.
3. Metal plates, connectors, screws, bolts, and nails exposed direcfly to the weather or
subject to salt corrosion in costal areas, shall he stainless steel or hot dipped
gvanlZed
Where windows and doors interrupt wood structural panel sheathing and s~tsng,
framing anchors or connectors shall be provided at the top and bottom of crfflple
studs, header studs, and at least one stud at each side of opening
5. Ridge straps shall be attached to each pair of oppomng ratters except where collar
ties of 1 x6 or 2x4 lumber is located m upper third of attic space and attach to each pair
of ratters.
6. Uplift connectors shall be provided at each rafter bearing.
7. Floor to floor hold-downs to be provided every 48, and every 16" within 4' of exfenor
cereals.
8. Sill Plate to Foundation Anchorage- Sdl plate shall be anchored to the foundation
with anchor bolts hawng a rain bolt diameter of 5/8" and 3" x 3" x 1/8" washers. A
mm~mum of one anchor bolt shall be prowded within 6 to 12 inches of each end of
each plate. Anchor bolts shtsl have a mmimum embedment of 7 inches ~n concrete/
masonry foundations. Anchor bolts shall be located withm 12 inches of comers and at
spacing not exceeding 4 feet on center.
THESE NOTES ARE GENERAL CONSTRUCITON NOTES, THEY ARE NOT
SPECIFICALLY WRITTEN FOR TH~B PLAN THEY ARE TO BE CONSIDERED AS
GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WiTH YOUR
GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS.
JOINT DESCRIPTION NAIL QUALITY NAiL SPACING
~5 S~C PIGH ~D E3~GN W~XDD Fp~
P-A~ I E.H SF'AQNG 16' Q'C
~1; 11 14
4:1~ 8 11
5:12 7
7:12 r 6
~12 5
1~12
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
WEATHERING SEVERE
FROST LINE DEP"R-I 3'47'
'I~RMI]E MODERATE TO HEAVY
DECAY SLIGHT TO MODERATE
WIN~ER DESIGN TEMP 11
ICE SHIELD UNDER- AS PER MANUFAC~JRER'S
LAYMENT REQUIRED SPECIFICATIONS / STATE COD~-
FLOOD HAZARDS
TABLE 3'41 r
1995 SBC HIGH WIND EDITION WOOD
:RAME CONSTRUCTION MANUAL
RAFTER S PACING 16" CiO T
12(] mph FASTEST WlNDSPEED
ROOF ROOF NUMBER
PITCH SPAN (ft) OF NAILS
412 12 3
15 4
20 5
24 6
20
24
28
32
36
SOUTHOLD BUILDING D~ARTMB~' ~,rt~ I ~.~A
OCCUPANCY CLASSIFICAllON R~3 RESIDENTIAL - SEC~ON 310 BUILDING CODE N Y.S.
USE DWELUNG UNIT- SECTION 310 - 310.2
2 HEIGHT TOTAL[24'4"
FIRE AREA (st)
TYPE OF CONS~UCllON NeeD FRAME CONS~:~UC~ON
4 DESIGN CRITERIA :RESL;I-(iP' BVE DESIGN - 1995 HIGH WIND EDI"gON WFCM
5 FRAMING ELEMENTS SEE FLOOR PLANS AND SECllONS
6 DESIGN LOAD CALCULATIONS SEE PG 6 & 7
7 WINDOWAND DOOR SCHEDULE SEE PG 9
8 LOAD PAtH SEE PG 6 & 7
I
9 NAILING SCHEDULE SEE PG 8
10 EGRESS SEE PG 9
11 PLUMBING RISER DIAGRAM N/A
12 FIRE PROTEC~ON N/A r
13J fRUSS DESIGN DRAWINGS N/A
14 ENERGY CALCULA~ONS SEE ATTACHED
Ld b-
RAFTER [ ( ' KINGSTUDS
I I / JACK STUDS A RAm~RIDGEIm~R W~ CT ' ~S250 21"
2ND. FLOOR WALL STUD ~ , 2ND. FLOOR WALL STUD I 1SI. FLOOR WALL STUD~ [:, ~ I 1ST. ~OOR WALL S~D
2ND. FLOOR PraTE ~: > / 2ND. FLOOR P~m -,:~ I I I ~ POST ANCHOR FOR CO.RED PORC,ES
RIM BOARD ] RIM BOARD 4 SUBFLOOR -, , , SUBFLOOR
I, . ~ USP RS250 AT 36' ~ ~,
RIM BOARD ~1 ~" RiM BOARD
~FLOOR TO FLOOR ~FLOOR TO FLOOR ~ STUD/P~TE/SILL ._ ~ STUD/P~TE P~TE/SILL ~ POST ANCHORS FO. ~C~S
i I / JACKSTUDS A RAFTLR/RIDGE/RAF~RWI%ICT' ~S250 21"
2ND. FLOOR PLATE ~: I / ~ 2ND. FLOOR PLATE - ,:' I I I ~'G ~ POST ANCHOR FOR COVERED PORCHES
,
IsT.USPKLFTAFLoORTOP PLATES ~ Ir i ~ IST. FLOORTOPPLATES ~ I ; USPRS250AT36" ,-, ~ USPRS250AT16"
I
(~FLOOR TO FLOOR ~)FLOOR TO FLOOR ~ STUD/PLATE/SILL ._ ~) STU D/PLATE PLATE/SI LL ~ POST ANCHORS FOR ~ECKS