HomeMy WebLinkAbout1000-102.-2-12.5 NO
PARKING
ANYTIME
NO pAKK~NG
NO STOPPING
P4-6 PLAN VIEW
(N,Y.S.D.O.T.) HC & ACCESS DETAILS
(SEE SITE PLAN FOR LOCATION) N.T.S,
PLANTING SCHEDULE: STREET TREES PER L/PA
W/RE FRIENDLY TREE PROGRAM
(*MIR 8' HIOH)
8 SHRUGS-- EVONY Mus. r.-- GOLD GPA$G AND HOLLY BERRY NiCE "LLEX V. GERRY NiCE
EN THE EVENT THAT THE EXISTING STREET TREE AS INDICATED ON THE PLAN AS 18" DIAMETER MAPLE TREE ALONG THE MAIF
CURB
SECDON G-G
a period of three (3) yeats from thc d~c ofappto¥~ ~,~ ~
4
APPP. OVED BY
PLANNING BOARD
TOWN OF SOUTHOLD
DATE ~AR ' 8 2010
[] 4 LOCATION OF FOOTCANDLE READING
MAINTAINED FOOTCANDLE VALUES AT GRADE,
USING A .72 MAINTENANCE FACTOR.
SiaUsUcol Area Summary
Project: OWEN
Label
Avg Max
INSIDE PROPERTY 0.8 11.5
Mtn Avg/Min
0.O 0 O0
Max/Mtn
0.00
laboratory data
This hghUng pattern represents illuminabon levels calculated from
taken under controlled conditions utilizin9 current industry standard lamp ratings in
accordance with Illuminating Engineering Society approved methods. Acutal performance
of any manufacturer's lumineme may vary due to variation in electrical voltage, toleronce
in lamps and ether variable Ee[d conditions.
1. IN THE EVENT THAT THE EXISTING STREET TREE AS INDICATED ON THE PLAN
AS 18" DIAMETER MAPLE TREE ALONG THE MAliN ROAD EXPIRES, iT SHALL BE
REPLACED BY TWO FLOWERING MAPLE STREET TREES 20' OC AS PER TOWN
CODE SECTION 161--44
2, IN THE EVENT THAT THE EXISTING STREET TREE AS INDICATED ON THE
PLAN AS 2¢" DIAMETER MAPLE TREE ALONG THE MAIN ROAD EXPIRES, IT SHALL
3E REPLACED 3Y TWO FLOWERING MAPLE STREET TREES 80' DC AS PER TF~WN
CODE SEC] ION 161-44
3. IN THE EVENT THAT THE EXISTING STREET TREE AS INDICATED ON THE
PLAN AS 23" DIAMETER MAPLE TREE ALONG THE MAIN RBA]~ EXPIRES, IT SHALL
]~E REPLACED BY TWO FLOWERING MAPLE STREET TREES 20' OC AS PER TOWN
CODE SECTION
%,%
ROQTE 4-8 (,AKA NORTH ROAD)
RTE, 25 (AKA MAIN' ST,)
SITE KEY MAP NTS
LOCATION -
CONTACT ENGINEERING INSPECTOR (765-1560) AT LEAST 24
HOURS PRIOR TO THE START OF ANY WORK. WORK PERFORMED
WITHOUT INSPECTION SHALL BE CERTIFIED TO THE ENGINEERS
SATISFACTION AT APPLCIANT'S EXPENSE. PLACEMENT OF FILL
INSTALLATION OF RETAINING WALLS, DUMPING OF MATERIAL,
EXCAVATION, MINING, OR SIMILAR DISTURBANCE OF LAND REQUIRES
AN APPROVED SITE PLAN. COMMENCEMENT OF ANY ACTION OF THE
ABOVE WITHOUT APPROVAL IS PROHIBITED AND SUBJECT TO LEGAL
ACTION.
SURVEY DATA
NATHAN TAFT CORWIN,L.S.
322 ROANOKE AVE
RIVERHEAD, NY 11901
(631) 727-2090
SITE DATA
SCTM # 1000 -102 - 02 -12,5
ZONE RESIDENTIAL
JEXISTINO IMPROVED LOT 20,224 SF (,¢64 AC)
AKA "NEW PARCEL 1')
STING BLDG FOOT PRINT AREA= 1563 SF
EXISTING GARAGE FOOT PRINT AREA- 635.6 SF
PROPOSED BLUESTONE PARKING AREA= 5644.3 SF
PROPOSED LANDSCAPED AREA= 10,397.1 SF
PROPOSED ASPHALT RC PARKING = 910 SF
EXISTING CONC &~ BRICK WALK WAYS, PATIOS,
PROPOSED TIMBER TEK BC RAMP - 1074 SF
PARKING REQUIREMENTS:
2700 SF OFFICE =
18 STALLS (150 SF = 1 STABL)
INCLUDING 2 HC PARKING STALLS
TOTAL PARKING PROVIDED -
18 STALLS (INCLUDING 2 HC STALLS)
IMPERVIOUS SITE DRAINAGE
PROPOSED TOTAL IMPERVIOUB
SURFACE REQUIRING DRAINAOE
(BUILDINGS, BRICK &CONC, WALKS,
PAVED HC PARKING, HC RAMP)
- 4182.6 SF
WITH 2" RAINFALL
¢182.8 x .16 = 869.2
669,2/68.4 = 9.7/(IO'DEEP POOL)
= 1 LEACHING POOL REQUIRED.
PARKING DRAINAGE
PROPOSED TOTAL BLUESTONE
SURFACE REQUIRING DRAINAGE
(NO CURBS) = 5644.3 SF
WITH 2" RAINFALL
5644,3 x ,16 = 903
903/68.4 = 13.2 -
1- 14' DEEP LEACHING POOL REQUIRED,
LANDSCAPE DRAINAGE
80 % PERVIOUS SURFACE = 10,397,1 SF
WITH 2" RAINFALL
10,397.1 x ,16 = 1680
80% OF 1680 - 16335 / 684 =24,32
/ (1)-12' DEEP POOL & (1)-13' DEEP POOL)
= 2 LEACHING POOLS REQUIRED.
SANITARY REQUIREMENTS:
ALLOWED: 300 GPO/ACRE
'.464 AC 192 GPO
PROVIDE 1200 GAL SEPTIC TANK
& (1) 10 X 12 LP
PROPOSED NEW SEPTIC WILL
BE LOCATED THE REQUIRED
DISTANCES FORM PUBLIC WATER
LINES, DRAINAGE LEACHING
POOLS, ETD, AS REQIRED
USE
ABANDON RESIDENTIAL USE ~
PROVIDE PROFESSIONAL OFFICES
ZONE : R-O
"RESIDENTIAL OFFICE"
MIR LOT SIZE
REQUIRED: 40,000 SF
PROVIDED; 20,224 SF (,z-64 AC.)
MIR LOT WIDTH AT FRONT STREET
REQUIRED: 150 FT
PROVIDED: 124,75 FT
MIR LOT DEPTH
REQUIRED: 175 FT
PROVIDED: 199.77 FT
MAX LOT FAR (NO CHANCE)
ALLOWED: 20%
PROVIDED: 10.87 %
MAX IMPERVIOUS SURFACE
ALLOWED: %
PROVIDED: 17 %
MAX HT OF BUILDINGS
ALLOWED: 35 FT
PROVIDED: 35 FT
(EXISTING- NO CHANGE) >-
MIR FRONT YARD
REQUIRED: 50 FT-OR o
AVG. OF ADJACENT PROPERTIES
PROVIDED: SOUTH 40.3' FT
WEST: 12.4 FT
SIDE YARD ~--
REQUIRED: 15 FT
PROVIDED: EAST =30'-6"'
SIDE YARD TOTAL COMBINED
REQUIRED: 35 FT
PROVIDED: 42.9' FT
MIR REAR YARD DEPTH
REQUIRED: 50 FT
PROVIDED: 113' (MAIN BUILDING) SHEET NO,
NYS LIC. NO. 50467
S I k PI AN BCT : 060 O -. ET,REDi1900_ O _O ,
-- __ JIJNE 1, 2004 SCALE 1;20 PROVIDED = .05'
NEW PARCEL 1 20,224,28 SF
ALE: 1" = JUL~ 12, 2004 ADDE; BUILDIN~ COVERAG~ OVE~ NEW PARCEL 2
JULY 15, 2004 ADDED BUILDING COVERAGE OVER NEW PARCEL 1
EXISTING HOUSE
SANITAEY SYSTEM DETAIL
N.T.S.
NOTES:
1, ELEVATIONS ARE REFERENCED TO AN ASSUMED DATUM
EXISTING ELEVATIONS ARE SHOWN THUS:
2. REFER TO FILED MAP FOR TEST HOLE DATA.
S, MININUM SEPTIC TANK CAPACITY IS 1,200 GALLONS,
1 TANK~ 8' DIA., 4' LIQUID DEPTH
50~ FUTURE EXPANSION POOL
I0~ DIA, X 12' DEEP SANITARY LEACHING POOL
1,200 GALLON SEPTIC TANK
fi, THE LOCATION OF EXISTING WELLS AND CESSPOOLS SHOWN HEREON ARE FROM FIELD
OBSERVATIONS AND/OR DATA OBTAINED FROM OTHERS.
10-0" MIN
SEPTIC TANK
8-0" MJN ~
Jo= 48,70'
LEACHINO
POOL ~
~ FROM GRADE
17' DEPTH
(~-MANHOLE COVER
x 50
POOL
RTE, 25
(AKA MAIN ST.)
SITE KEY MAP NTS
LOCATION
SITE DATA
SCTM # 1000 -102 - 02 -12.5
ZONE -RESIDENTIAL/OFFICE
EXISTING IMPROVED LOT 20,22~- SF (,46z~ AC)
AKA "NEW PARCEL 1")
XISTING BLDG FOOT PRINT AREA= 1557 SF
:XlSTING GARAGE FOOT PRJNT AREA= 655,6 SF
SANITARY CALCULATIONS
NON- MEDICAL OFFICE = DB GPD/ SF
1557 sf FIRST FLOOR OFFICE NON- MEDICAL
1557 sfx ,06 gpd= 93,42 gpd
1269 sf SECOND FLOOR OFFICE NON- MEDICAL
1269 sf x .06 gpd= 76 14 gpd
637 sf OARAOE/ STORAGE
637 sfx .04 gpd= 25 48 gpd
TOTAL OPD= 195,04
GARAGE UNFrNISHED FOR VEHICLE PARKING
ONLY / NO STORAGE/ NO WATER SERVICE
BASEMENT UNFINISHED FBR MECHANICALS
DNLY NB STBRAGE
ATTIC .UNFINISHED FOR MECHANICAL
ONLY - NO STORAGE
SANITARY DENISTY CALCULATION
,464AC X 600 GPD/AC = 278,40 ALLOWED DPD
GROUND WATEN ZONE ~ IV
ALLOWED; 600 GPD/ACRE
, ,484 AC = 278,40 OPD
~ i' PROVIDED GPD= 195,04
PROVIDE MINIMUM SYSTEM
1200 GAL SEPTIC TANK 8' DIA X
4' LIQUID DEPTH & (1) 10 X 12 LP
PROPOSED NEW SEPTIC WILL
BE LOCATED THE REQUIRED
DISTANCES FORM PUBLIC WATER
LINES, DRAINAGE LEACHING
POOLS, ETC. AS REQIRED BY
SCHD SANITARY CODE,
TEST HOLE DATA
~z/z / os
SCTM # 1000 - 102 - 2 - 12,5 (11)
p~: ~K .,o',,'. LGA. (OL)
BY: McDONALD GEOSClENCE
SURVEY DATA
NATHAN TAFT CORWlN,L.S.
322 ROANOKE AVE
RIVERHEAD, NY 1190~
(631) 727-2090
NYS LIC. NO. 50467
SCTM: 1000 102 02-11 (RETIRED)
1000- 102 -02-125
JUNE 1, 2004 SCALE 1:20
NEW PARCEL 1 20,224.2B SF
C, F
completed form ~h{- as proof
~'¢¢'. . . ¢ ENGINEER'S ;ERf;F,CAI,OH -[,'T::°
S,,r F PLAN
SCALE:i = 20'
~ ~ have ~ ~ ~ ~1 ~ ~th S~Ik
JULY 12, 2004 ADDED BUILDING COVERAGE OVER NEW PARCEL 2
JULY 15, 200¢ ADDED BUILDINO COVERAGE OVER NEW PARCEL 1
SCH
REF,# C10 09 0001
Z
SHEET NO
S1