Loading...
HomeMy WebLinkAbout34174-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34211 Date: 02/25/10 THIS u~KTIFIBS that the building ADDITION & ALTERATION Location of Property: 1350 SMITH DR N SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) Co~t¥ Tax Map No. 473889 Section 76 Block 2 Lot 9 Subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 17, 2008 pursuant to which Building Permit No. 34174-Z dated SEPTEMBER 19, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION AND ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JOHN J CARWAY of the aforesaid building. ( OWNER ) SDFFOLKCO~DEP~T~NTOF~J%LTH;~PRO~AL N/A EI~C~£KICAL U~'rIFIC~%TH NO. 08-9295 12/02/09 PLUMBER~ U~TIFICATION DA'r~ 12/19/08 NICK SALVATO Rev. 1/81 BLI)G. TOWN OF SOUIHOLO Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey &property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by thc applicant. If a Certificate of Occupancy is denied, thc Building Inspector shall state the reasons therefor in writing to the applicant. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00. Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00. Commercial $15.00 Date. ~ Old or Pre-existing Building: ~/d~ (check one) House No. Street H~et New Construction: Location of Property: Owner or Owners ofProperty: ~ ft~[^~lA ,__[ , C(A ~('c~ ~ Suffolk County Tax Map No I OOO, Section 7 ~ Block Lot ~ Subdivision Filed Map. Lot: Permit No. ~ ~//~/ Date of Permit. ~/~ ~/~) ~J~ Applicant: ~'//~ ~?~-~ .~"'~ Underwriters Approval: Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ o~ ~ Final Certificate: (check one) P~pplicant~gnature 7 Electrical Inspectors, Inc. 308 East Meadow Avenue East Meadow, NY 11554 Office: (5[6) 794-4)400 (631)396-7474 Fax: (516) 794-5854 Website: www,electrica]inspectors.com Email: in fo~electricalin spectors.com Mail To: Lamond Electric Corp. George Lamond PO Box 652 Wading River, NY 11792 License#: 3428 Certificate Number: 08-9295 Municipality: Southold, Town Of Inspector: 124 Issue Date: 12/2/2009 A Southold, NY~ ELECTRICAL APPROVAL ?RTIFICA TE AREAS LISTED BELOW ARE APPR)~, Pt/ INSPECTION herein below only. Residential Inspection 1st Floor: Bathroom, Bedroom. Walk-ln Closet 2nd Floor: Bathroon Closets 18- Duplex Receptacles, 2- GFI Receptacles. 9- Recessed Fixtures, 8- Incandescent Fixtures. 3- Paddle Fan Outlets, 4 Ft. 200Amp Single 200Amp Single Phase Main Panel/4OCkts/31 Used. * Rough 12/31/08 Final 12/1/09 Richard M. Bivone President Philip F. Goehring Chief Electrical Inspector Not valid unless signed by an authorized EII Agent 12-18-08;18:57 ; 915167523889 ; # 1/ 'r~,~n Nail, 53095 Main Road P.O.. Box 1179 Snuthold, New York 1]971-0959 *Fax ('631) 765-9502 Telephane (631) 785-1802 BUILDING DEPARTMENT TOWN O1~' CERTIFICATI. ON 1:lumber: (Please prinO (Please print) Date: I certify that the solder used in the water SLq*lAy system contains less thau 2/10 of 1% lead Not~y Public, ~d County JO ANN DUBATO ~W Public, State of New York No. ~3~13 uahfl~ in Nassau CounW ~ .~ O *' ~/v ~mmi~ion E~ires May 2, ~ FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34174 Z Date SEPTEMBER 19, 2008 Permission is hereby granted to: JOHN J CARWAY 155 EMORY RD MINEOLJ~,NY 11501 for : ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1350 SMITH DR N SOUTHOLD County Tax Map No. 473889 Section 076 Block 0002 Lot No. 009 pursuant to application dated SEPTEMBER 17, 2008 and approved by the Building Inspector to expire OhM_ARCH 19, 2010. Fee $ 200.00 / 'A ' z'ed Signature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FO~I~DATION 2ND [ ] INSULATION [~/~FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION DATE~INSPECTOR~~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT ION [ ] FOUNDATION 1ST [~/ROUGH PLBG. [ ]FOUNDATION2ND [ ]INSULATION []FRAMING/STRAPPING []FINAL []FIREPLACE&CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS.[ ] FIRE RESIS~ANTC~NST~RUCTION [ ]FIRERESIS~,~PENETRATION {~~/~ ~' [~/~ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [/~RO~BG. [ ]FOUNDATION 2ND [/~tNSULATION [ ]FRAMING / STRAPPING [ ] FINAL [ ]FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]FIRERESISTANTC~RUG~//ON [ ]~IRERESI~ST,~PE/~~ REMARKS: _ ~ DATE INSPECTOR~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION _~FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: INSPECTOR FI2ELD 12qSPECTION REPORT FOUNDATION (1ST) FOt,~DATION (2ND) '-I- ~S~ATION PER N. Y. STATE ENERGY CODE ~DITION~ COUNTS TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined q/Jr, 20 OJ7 Approved !//~, 20 0~// Disapproved a/c Expiration PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey .~ ] ~¢~-~ Check ~00, O0 Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: ! - Building Inspector APPLICATION FOR BUILDING PERMIT t l -- ' J I Date I~_ 9_ ,20 .~ [ ~ INSTRUCTIONS ' g-~ a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, arid waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. · d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sig~lre o~ap~can~or~r~) " - (~Iailing address of applicarnt) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ~'~ ~) [,/~A~"~ · (~s~ll If applicant i~} c~'poration, signature of duly authorized officer .try (Name arid title of corporate officer) or latest deed) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on, which pro,posed work will be done: House Number Street t I4arfilet County Tax Map No. 1000 Section Subdivision Block ' ~ .... Piied Map No:' Lot (~ Lot State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existinguseandoccupancy f .~ S t dk ,ea,~r .~ ~ ~,t,~ [.a ~ ~ L, b. Intended use and occupancy ~-~- ,2 ~ ¢(¢~,, c ~ 3. Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost ~./ ~D ~ ~ ~ {3 ~ 5. If dwelling, number of dwelling units ~ If garage, number of cars Addition ~ Alteration Other Work Fee (Description) (To be paid on filing this application) Number of dwelling units on each floor ~ ~ 14 ~4~r~'~ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 8. Dimensions of enti~ new construction: Front ~'~, ~ Rear Height ,2-~/, 3~' Number of Stories ~ 9. Size of lot: Front ~)2c~-, '7.~'"" Rear ¢~, ~ Depth Dimensions of existing structures, if any: Front ~'-q, ~ Rear ~-7' Height 7~'{ , ! ~7 Number of Stories Dimensions of same structure with alterations or additions: Front Depth 2..~. ~-, Height 2-7, .F- Number of Stories 3'-7, ,~ Depth Depth 2- ~" ' fl Rear/fi?. 10. Date of Purchase ~C~T. I'~'~' 7 Name of Former Owner 11. Zone or use district in which premises are situated __~ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO f. 13. Will lot be re-graded? YES__ NO )0 Will excess fill be removed from premises? YES__ NO 14. Names of Owner ofpremise~Address/,~'~f ~m,~,- , ~,~, A~/,,0/Phone Ne. X0, Name of Architect Address tzc~ a~S ~'~_,2. ~Phone No rtt, ?¥ Name of Contractor Addres~~l~hone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO ~ 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO __ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) COUNTY OF<~ S)s: (Name of individual signi~ above being duly sworn, deposes and says that (s)he is the applicant named, (S)He is the o ~ ~.~/ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. 155 Emory Road Mineola, NY 11501 516-248-1929 John J. Carway cell 516-521-4023 iicarwa¥~aol.com 1350 Smith Drive North Southold, NY 11971 631-765-2161 September 4, 2008 Ms. Patricia Conklin Building Permits Examiner Building Department Southold Town Hall 53095 Main Road PO Box 1179 Southold, NY 11971 Dear Ms. Conklin Enclosed is the original sealed copy of the "Certification of Existing Subsurface Sewage Disposal and Water Supply Facilities For A Single Family Residence" Health Depa~*b~3ent Form WVVM-072 (Rev. 08-06) for the 2n°story addition to my home at 1350 Smith Drive North, Southold. It is signed and sealed by James J. Deerkowski, Professional Engineer, 260 Deer Drive, Mattituck, NY 11952 Thank you for your assistance thus far. If them are any further issues, the best way to contact me is by my cell phone, 516-521-4023 or by email at iicarwa¥~.aohcorn. Thank you again. Eric, Suffolk County Department of Health Services Health Reference Number Office of Wastewater Management 360 Yaphank Avenue, Suite 2C - Yaphank, NY 11980 (631) 852-5700 Certification of Existing Subsurface Sewage Disposal And Water Supply Facilities For A Single Family Residence A. Property Information 1) Address of Residence: Street ~ ~CJ ~3~31~r.~ b~T~,~ Hamlet SO ~-T ~ 0 C'~'~ Zip 2) Tax Map Number: District Section Block Lot(s) 3) Owner's Name ~"~fP~ ~.,,~.~q~-'~ Phone 4) Client's Name (if different than owner) 5) Proposed changes in use (e.g., addition of apartment, bedrooms, office, etc.) B. Sanitary System Evaluation: ** Sanitary System(s) must be pumped out and physically examined by the certifying design professional. 1 ) Type of Water Supply: ~Public Water [] Pdvate Well - Provide copy of water analysis dated within one calendar year 2) Date of sanitary system pumping ~. tq ]0~-~ total gallons removed '~'.Precast [] Block* 3) Materials of construction of sanitary sys! em *NOTE: Block pools are no longer accepted - sanitary system must be replaced 4) Size of Sanitary components*: Septic tank ! ¢.x:D~ gallons ~ >~ ~' diameter, or dimensions if rectangular c~ .O f effective depth Leaching Pools <~, Q diameter /2, (,~ effective depth '~_ total number of pools *NOTE: Sanitary components must meet current standards for proposed use or upgr. ading wilt be required. (waste lines, drop tees, baffle walls, covers, septic tank, leaching~3ools)\~ ~..,, ~.j~... '~' ~ ~'..' · , Certification: The results and recommendations found in this report are based upon my evaluation and inspection of the above referenced property and pumped out sanitary system: Mailing Address:-~ ~_~,(~O ~,"~_...~, ('~-,,,,j~ WWM-072 (Rev, 08/06) Page 1 of 2 C. Recommendations And Results (Check applicable items): 1. Sewage System a. X System(s) functioned properly at time of inspection and is adequate for the proposed use. __ System(s) is not adequate for the proposed use (explain and make recommendations in Section D below or attach a separate report). c. Other 2. Water Supply Water supply is adequate for proposed use (if private well, attach water analysis dated within one calendar year). __ Water supply is not adequate for proposed use (explain and make recommendations in Section D below or attach a separate report). c. Other D. Other Comments/Recommendations: Disclaimer: This inspection report indic~tli_e~ Condition of the private on-site subsurface sewage disposal system and water supply 'based on recommended inspection procedures. The results of this inspection do not guarantee or warranty future ~rformance. The recipient of this report should discuss any deficiencies found by this inspection with the individual who prepared the report. WWM-072 (Rev. 08/06) Page 2 of 2 Town of Southold Erosion, Sedimentation & Storm-Water Run.off A88ES8MBNT FORM PROPERTY LOCA~TION: $.C.T.M.#: ~(~ THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A ~.~,~ ~1~ ~;~ ~_ ij~J~'~_S_TORM-WATER, GRADING, ERAINAGE AND EROSION CONTROL pLAN ~ Section Clock [o~ CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. Number: (NOTE: A Check Mark (,~) for each Question is Required for a Complele Application) Y No 1 Will this Project Retain Ali Storm-Water Run-Off Generated by a Two (2") Inch Rainfall on Site? (This item will include alt run-off created by site clearing and/or construction activities as well as all Site Improvements and the permanenl crealion of impervious surfaces,) 2 Does the Site Plan and/or Survey Show All Proposed Drainage Slroctures Indicating Size & Location? .,~/,~. ~ / ~' This Item shall include all Proposed Grade Changes and Slopes Controlling Surfa.~,e WateC::low! /v/[/~.~,~__ ¢-7./"/¢/' ' ' 3 Will this Project Require any Land Filling, Grading or Excavation where there is a change to the Natural F'~ ~ Exlsling Grade Involving more than 200 Cubic Yards of Matedal within any Parcel? I~1 -- Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000) Square Feet of Ground Surface? 4 Is Ihere a Natural Water Course Running through the Site? is this Project within the Trustees judsdiclion or within One Hundred (100') feet of a Wetland or Beach? 5 Will there be Sile preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vedicaf Rise to One Hundred (100') of Hodzonlal Distance? 6 7 8 9 Will Driveways, Parking Areas or other Impervious Surfaces be Sloped Io Direct Storm-Water Run-Off into and/or in the direction of a Town dghEof-way? Wifi this Project Require tine Placemenl of Malarial, Removal of Vegetation and/or the Construction of any Item W he fown R 9 -o -Way or Road Shoulder Area? (This item will NOT include the Installation of Driveway Aprons.) Wfil (his Projecl Require Site Preparali!ln within the One Hundred (100) Year FIoodp a n o any Walercourse? M NOTE: If Ally Answer toQuesEons One through Nine is Answered with a Check Mark in the Box, aStorm-Water, Grading, D~inage & Erosion Control Plan is Required and Must be Submi~ed for Review Prior 1o Issuance of Any Building Pennifi EXEMPTION: Yes Does this project meet the minimum standsrds for classification as an Agricultural Projec[? Note: If You Answered Yes to this Questiom a Storm-Water, Grading, Drainage & Erosio~ Control Plan is NOT Required! STATE OF NEW YORK, Owner and/or m~e ~d file fl~at d~e work .dll be perfl~rmed in d~e mnmae~ scl forth in d*c application filed herewilh. Sworn 1o bclor e me this; Nota~ Pub c' ,I SMITH DRIVE NORTH~ p~ N.80° 30'O0"E. 99.50' " AREA - 9,762 SQ. FT. / LOT 106 CERTIFIED TO , LAWYERS TITLE INSURANCE CO. BAYSiDE FEDERAL SAVINGS & LOAN ASSOCIATION JOHN CARWAY JACOUELINE CARWAY P.O. I~ MAIN ROAD SOUTHOLDt N.Y. 1197r NO. SURVEY OF PROPERTY AT BAYVIEW TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. lO00 070 02 09 SCALE 1" ~ 80' AUG. 12, 1988 496tS LOT NUkiG~.R$ REFER TO ~ * MAP OF GOOSE NECK Permit Number Checked By/Date MECcheck Compliance Report New York State Energy Conservation Construction Code MECcheck SoRware Version 3.3 Release lc Data filename: Untitled TITLE: caraway residence COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached l or 2 Family HEATING TYPE: Non-Electric DATE: 03/10/08 DATE OF PLANS: march 10, 2008 COMPLIANCE: Passes Maximum UA = 137 Your Home = 116 15.3% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value N-Factor UA Ceiling l: Flat Ceiling or Scissor Truss Wall l: Wood Frame, 16" o.c. Window I: Wood Frame, Double Pane with Low-E 760 30.0 0.0 27 904 13.0 0.0 69 63 0.320 20 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed,this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or, specifications are in compliance with this Code. Builder/Designar ~t'~ Date MECcheck Inspection Checklist New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lc DATE: 03/10/08 TITLE: caraway residence Bldg. Dept. Use [ ] [ ] [ ] [ ] [ ] [ ] [ ! [ ] [ ] [ ] I. ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Wood Frame, Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: # Panes__ Frame Type Thermal Break? [ ] Yes [ Comments: ] No Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. lnsulatinn is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heatem with vertical pipe risem must have a heat trap on both the inlet and outlet unless the water heater has an.integral heat trap or is part ora cimulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools:. All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thicl~ness for Circulating Hot Water Pipe& insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Cimulating Mains and Runouts Temperature (F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range (F) 2" Ranouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) GENEP-JkL NOTE5 GENERAL NOTF5 ~, THE CONTRACTOIb' 5NALL REMOVE RELOCATE, EXTEND AND ~NSTALL ALL EXISTING THE ?LAN5 AND~ IN ~TP~CT COMPLIANCE ~VITH THE STATE, FEDERAL AND LOCAL IONS. A~D A(L ~THFP- ApI~UCADLE CODED AND FJ~GULATIONS. 3. UNLES~ 5PFC E~CALLY NOTE? OTHEP`WISE THE CONTP. ACTOR. 5HALL pP. OVIDE FOP. ~ AND':CC,'.O.R.DiNATE ALL LABOI~ MATERI~LS, EOMJP~ENT TOOLS, MACHiNER.Y AND OTHEP. ffAC U~.l~t ~.N,D 5EP. VICES. N ECE55AP-Y' f'OP. THE pp.Q~I~ EXECUTION OF THE WOPJ~. HE OWNER A 20 YEAR GUARENTEE ON THE ROOFING ,. ,,, CONTEACTOP` 5HALL FIELD VEP`IF ( ALL EXISTING CONDITION5 AND P. EFOP`T ANY DISCP. EPANCIES~ ON HE ARCHITECT IN J_ MECHANfCA~ AND ELECTRICAL . DEM~ 5TING CON.~TR.UCTION AD INDICATED ON THE [=LAND. DEMOUTION I. FEELS VE~ ALL DIMEN~ION5 P~OP TO P~CtNG CONCUR. ~, ALL CONC~E'WO~ 5~A~ CONPO~ TO THE A~l 3TANDA~ ~PE~NCE NUMO~ 316-~ CONCUR OE ACI 55~-99/~CE 5-99~M~ M~ON~5~CTU~. ~. A~ CO~ ~HA~ HAVE A M~IMU~ CO~P~IVE 5T~NGTH WITHIN 2~'~A~. ~B~ ~po~ED T~H~ W~THE~ k CONCUR DT~NGTH OP ~5~0 PSI WITHIN 2~ 4. ffOOT~NG5 5~A~ ~E ON VIRGIN '50il WITH A M~NIMUM OF ~ TON3 ~ DQUA~ FOOT DEA~N~ CAPAC~ AND ,THE ~OIL 5HA~ HAVE A MATE~AL O~WISE~NOTED 7. FL~OR 5~D5 5HA~ HAVE A"SMOQTH 5TELL T~L F~NtSH DOLT5 ~TH A ~INIMUM E~GHT-INCH EMDEDMENT ~TH A THeE-INCH HO0~ P~CED AT FIVE AND A, flA~ INC'H~ ON CENTE~, THE ENTI~ F~TE ~5 TO 'D~ ON THE FOUNDATION WA~. A~ 5[~ P~T~ A~ TO {~E T~TE~ T~ ~515T TE~ITE DAMAGE. , P D HOT ;'A~ A~OEBOLT~ A~ TO OE STAIN LE55 5TELL OE DOUD~ PTVE-EIGHT5 DIAM~ AND HA~ A MINIMUM ~D~MENT OP INDICATED ON T~E AND A'MINIMUM OF Off I ~-INCH~ FEOM A~ F~TE END5 AND A M~IMUM MANUAL HIGH WIND EDITION 2. pROVIDE HEADER.5/%5 POLLOW~ (UNLE~50THEP`WISE ' I oPENING Ti t~EADEP` (2) 2x~'5 2 ~ , (2} 2Xt 2"5 5 ALL 5TEEL REINFOR.CING INDICATED 5HALL CONFORM TO ADTM AG I 5, GRADE 5 ALL BTEEL COLUMN5 BHALL HAVE A 5HOP APPLIED R.UST INHIDITER TREATMENT. G, ALL 5TR.UCTUr~,AL ~TEEL CONNECTION5 DHALL BE WELDED, UNLE~ OTHER.WISE NOTED. ALL WELDING 5HALL CONffDRM TO THE CURJ~ENT AW'D DPECIFICATJONS. 7. ALL STANDARD PIPE COLUMN5 AY,[ TO HAVE A EW OP 3(; KDI. 6, THE BTP`UCTUlEE FOP', TNI5 pR.OJECT HAD BEEN DESIGNED AND P`EVIEWED BY AREA LIVE LOAD DEAD LOAD TOTAL LOAD PIP~DT FLOOR 20 I 0 50 CARPENTRY 1 DOUBLE ALL FLOOR. JOIBT UNDER. FART T ON~ P.UNNING PARALLEL TO THE JOtBT, IN THE EVENT THAT THE JOIST ARE SEPARATED TO ALLOW FOP-, THE IfN5TALLAT~ON OF ~'IPING OR. VENT~ THEN THE JOIST ARE TO BE DLOCI~ED WITH DLOCEING NOT LE~B THAN 2 NCHE~ THICF. AND ~PACED NOT MORE THAN POUF` PR[ET ON CENTEP`. 2. ALL JOIBT, DRAM5 OF` GIRDER.5 5HALL HAVE NOT LES5 THAN ONE AND A HAL~ NCHF--5 OF BEAPJNGI'ON WOOD AND 3 INCHED OF BEAPdNG ON MA.~ONR.Y UNL~ MOiBTUP-E * THEPJVlAL PROTECTION I. ASPHALT ROOF SHINGLE5 5HALL BE OWEN5 CORNING CLIMATIC ¢ GEOGP-,A?HIC DESIGN CRITERIA GROUND SNOW LOAD 20 WIND S?EED 3 SECOND GUST 120M?H SEISMIC DESIGN CATEGORY N / A SUBJECT TO DAMAGE BY: WEATHERING SEVERE FROST LINE DEPTH TER]vIlTE HEAVY DECAY SLIGHT TO MODERATE WINTER DESIGN TEMP. I I ICE UNDERLAYMENT REQUIRED FLOOD HAZARD SMITH D IVE NO TI-I ~ N ~0° 30' 00" E ,~ 33o.7s T _-i j -I 5 ~0© 30' 00" W 99.5' I ~,,' ADDITION I 95.75' ~J ECT PLOT PLAN SCALE I '- ~32' NOTE5 THE INFOP~MATION ON THI5 PLOT PLAN WAD TAKEN FP.OM 5UR.VEY PP`EPARED BY ZONING INPOR, MATION PROPERTY IS LOCATED:) IN THE INCORPORATED TOWN OF SOUTHOLD, ITEM REQ'D LOT AR.LA <20,000 HEIGHT FKONT 3105 MiN I O' TOTAL 25' REAP` 35' LOT COVERAGE 20% N.Y. R-20 DIgTRICT EXISTING PROPOSED 35.33' 3~.~' 13 B3' NO CHANGE 39.75' NO CHANGE 34 63' 35' NOTE THIS PROJECT IS FOR a SECOND FLOOR ADDITION TO AN EXISTING ONE FAMILY, 2 BEDROOM RESIDENCE. THE ADDITION INCF. fASED THE NUMBER OI= DEDROOMB DY ONE AND THE NUMBER Of= BATHROOM5 DY ONE General Notes · LIST OF DRAWING5 II A- J GENERAL NOTES SITE PLAN AND ZONING A-2 PLAN, PLAN, INFORMATION FOUNDATION SECOND FLOOR ROOF PLAN A-3' FIRST FLOOR PLAN, SECTION, PLUMDING A-4 REOUI}~ PLUMBi~s ALL PLUMBING PLUMBER OER% ~LI ON LEAD cn~g~ SOLDER ~ ZUPPL Y SYs~ OT EXCEED ~0 OF I]~D, II ALL CONST~ ~'~ e~lAl L MEET TaE RI ,' ~],~ LJ,~ OF THE CODES OF NE~,M~u]i STATE, CERTIFI~T~N OF NAILING & Q~N~ECTIONS OCCUP,'.[ tm;. WITHOI,~i' C7~ OF OCCU2AN( ELEVATIONS HIGH WIND DETAILS 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS. FOR POUFI~ ' 3. INSULATION 4. FINAL - CONSTRUCTION MUST ALL CONSTRUCTION SHALL MEET REQUIREMENTS OF TBE CODES OF YORK STATE. NOT RESPONSIBLE DESI~ OR CONSTRUCTION RETAIN ~TOR~ WAIEp~ 1HE TOWN GEN.REV. Revlsion/!ssue STEPHEN 51WINSKI ARCHITECT 135 EMORY ROAD MINEOLA, N.Y. 11501 (5 I ~) 747-I 3(;;;8 ADDITIONS TO THE CARAWAY RESIDENCI I 350 SMITH DRIVE NORTH DOUTHOLD, N.Y, } I ~7 I ~,SEC.. BLOCK LOT 05 It 7 ~ 6-29~07, '~',, AS NOT[ 30'-4" PRO?OSED HOME O~P~C~ LCd/wALL e, e"~ PINI,SH NOTE.5 PROP. DEDROOM 5ATH ~ RXISTI NG EXISTING HALLWAY -, 5U~" 4" 1 0%3" FOUNDATrO'N ~ , ,;I ' ' " ": ';,' LAN 1 5E'CTIC)N PLUMBING: . EXISTING DECK EXISTING GARAGE EXISTING LIVING HEW BTAIR. AND ROOM ~ EQL. EQL. ST. PROP. BATH PROP. CLOS. 4" 4L2" @@ EXISTING DINING ROOM JI EXISTING BEDROOM FIELD VERIPY (2) 2×JO HDR FIRST FLOOR PLAN SCALE ~'L I LO" WALL KEY EXISTING [ DEMOLISH L. NEW SYMBOL5 l ATTIC %.¸ BEDROOM ~"~B~MBO^~° "-, '--..~, NEW N~ ,.~E~,o~ w^u_ ~o.~'~o.: C LOS. C LOS. oN ~ I EXISTING r m PROP. m BEDROOM m m 1 BUILDING ,.$ECTION SCALE ~"- I '-0" BATH TUB PLUMBING SCHEMATIC NO SCALE PLUMBING NOTES: I ALL PLUMBING INSTALLATIONS SHALL CONFORM TO STATE AND LOCAL [bUILDING CODE~ AND ALL AGENCIES HAVING JURISDICTION. 2,SUPPLY AND INSTALL SHUT-OPP VALVES, WHTH CROME PINISH, ON HOT AND COLD WATER LINES AT EACH PLUMBING PIXTURE, 3. HOT AND COLD PIPING ABOVE GROUND SHALL BE TYPE ILl, BELOW GROUND TFYE %' COPPER IS TO BE USED. 4. ALL HOT AND COLD WATER, PIPING 5HALL BE WP-,APP[ED WITH 3/4" FIBERGLASS PiPE INSULATION AND PR,E-FORMED FIDEP-.GLAS5 FOR FITTINGS 5. 50IL, WASTE, AND VENT PIPING ABOVE GROUND SHIALL BE AS PER, LOCAL CODES. 6, PIpING-SHALL BE CONCEALED WHEN PERMISSAI%E. '7. PROVIDE CLEANOUTS AS REQUIRED. ALL CLEANOUTS ~HALL BE ACCESSIBLE ¢. OWNER TO APPROVE ALL PIXTUP-,~S ¢. PLUMBER SHALL DO ALL NECESSARY ~(CAVATING, BACKFILLING, CUTTING AND PATCHING AS REQUIRED TO COMPLE'TE INSTALLATION. I O. ADHEARENCE TO THE NEW YOP-,K STATE RESlPENTIAL CODE FOR. CUTTING AND NOTCHING FOR INSTALLATION IS P-,EQUINES. ·General Notes LIST DRAWING,.5 A-I GENERAL NOTES SITE PLAN AND ZONING INFORMATION A-2 FOUNDATION PLAN, SECOND FLOOR PLAN A-3 FIRST PLOOR PLAN, SECTION, PLUMBING A-4 ELEVATIONS A-5 .,G. W, ND DESIGN DETAILS t GEN.REV. ~,/15 No. Revision/Issue Oate~ STEPHEN 51WINSKI ARCH ITECT 135 EMORY ROAD MINEOLA, N.Y. 1150 (5 I G) 747~ I 3G8 ADDITIONS TO THE CARAWAY RESIDENCE I 350 SMITH DRIVE NORTH ~OUTHOLD, N.Y. I ~71 SEC. BLOCK LOT 8-'ZD-Q7 · NOTED :~', NORTH ELEVATION SCALE ~"- ILO" lll lI IIlll~l I Ill Il ll Illi! ~ _~ !ll ll ii, l~l I I Ill I~ll I I IIl~ := 'Il i i iI'llll i i ill'il i ~ I' ~: = i!lll I!!l!ll I I l!l!l I ~ GRADE l~eneral Notes LIST OF DRAWINGS A-I NOTES ZONING A-2 PLAN, PLAN, GENERAL SITE PLAN AND INFORMATION' FOUNDATION SECOND FLOOR ROOF PLAN A-3 FIRST FLOOR PLAN, SECTION, PLUMDING A-4 A-5 DESIGN ELEVATIONS Ifl'IGH WIND DETAILS SOUTH ELEVATION 5CALF ~"- I ALUMINUM CLAD SOFFIT / WEST ELEVATION SCALE Y4"- ILO" GEN. REV. si 5, Eevlslon/I.sue STEPHEN SIWINSKI ARCH ITECT 135 .EMORY ROAD MINEOLA, N.Y. I 1501 (5 I G) 747-13G8 ADDITIONS ' 'TOTHE · ~/. CARAWAY RESIDENCE;.` SMITH D R,[VE ": 1350 NOR. TH" 50UTHOLD~'~N.Y. II ¢'7 I SEC. DLOCK , LO'I: ~5 '0517" ',. '"*' 6-29-07.. NAILING SCHEDULE OINT DESCRIPTION NUMBER OF NUMBER OF COMMON NAILS BOX NAIL5 I. NAILING REQUIREMENTS ARE BABED_ON WALL SHEATHING NAILED AT G" OiC,' AT PANEL EDGE. IF SHEATHING IS NAILED 3" O.C. AT PANEL .EDGE5 THAN NAILING IS TO BE DOUBLED. 2. WHEN SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF NAILS 5HALL BE REDUCED TO I - I Gd NAiL PER FOOT NOTE I = ALL PANELS 4" FROM CORNER5 SHALL BE NAILED $" O.C, AT EDGE5 AND G" O,C. AT PIELD, LEGEND: TN=TOE NAIL EH=FACE NAIL EH=END NAIL EXTERIOR WALL HEADER ANCHORAGE ON A B CDE FG 5TRAPPING VlEMBER NOTATIONS: (A) NUMBER OF 6d NAILS AT EACH END OF 5TRAPPING, I Od OR i Gd SINKERS FOR HDRS t0' TO I 2' LONG (B) NUMBER OF SILL STUDS ON THE FLAT ( NOT APPLICABLE TO DOORS) (C) NUMBER OF PULL HEIGHT KING STUDS AT EACH HEADER (D) NUMBER OPI Gd NAILS END NAILED THROUGH ADJACENT KING STUDS TO END Off HEADER AT EACH 5TUB. (E) NUMBER OF JACK STUD5 AT EACH END OF HEADER (fi) NUMBER OF I Gd NAIL5 END NAILED THROUGH ADJACENT JACK STUDS TO END OF SILL~ AT EACH SIDE (G) sIMPSON COILDTP. APPING LENGTH. TOTAL LENGTH OF ~TRAP IS HEADER DEPTH ( INCLUDING PLATES) PLUS DIMENSION INDICATED ON CHART ABOVE MI.N!MUM TOP PLATE 5PLI'CE LESS THAN SlX FEET DISTANCE NO I~" 22 GAGE COIL STRAP, SIMPSON CS20 NAILED WITH I O- I Od COMMON NAILS AT EACH RAFTER ROOF SHEATHING RIDGE 5TRAP DETAIL 564 LBS/RAFTER NO SCALE SIMPSON H5 ~ ~ G" O.C, NAILED WITH ~ 4_Ed COMMON NAIL~ TO RAFTER AND SIMPSON SSP ~ I G"" O.C, NAILED WITH ~- I Od COMMON NAI,I~ TO TOP PLATE AND 4- I Od COMMOhN NAI~ TO 5TUD~ ROOF SHEATHING ROOF RAFTER 2XG FASCIA BOARD VENTED SOFFIT Ya" PLYWOOD SHEATHING UP TO TOP OE PLATE PLATE 'TO RAFTER CONNECTION, 564 LDS/STLUD NO SCALE 2HID FLOOR FRAMING -- WALL FRAMING SHEATHING lY4" 20 GAGE COIL STRAP, SIMPSON C522 NAILED WITH 12- I Od COMMON FOR EACH CLEAR SPAN STUD TO 5TUB CONNECTION WHEN TWO STORIES EXIST NO SCALE 5G4 LBS/STUD NOTE fOR EXISTING CONSTRUCTION SUPPORTING NEW CONSTRUCTI©N AT I ST PLR. JOIST I . ALL EXISTING FRAMING SHALL SE STRAPPED WITH COIL STRAPPING ~ SHOWN FROM STUD TO STUD. 2, NAIL ALL ~5(I STING PLYWOOD SHEATHING A5 INDICATED ON SCHEDULE OR 1¢ I XG OR BOARD SHEATINING IS ~ISTING THEN NAIL W/2-1 OD NAILS AT EACH STUD WALL FRAMING SHEATHING ($) 2X4 CORNER STUDS 2ND FLOOR FRAMING -- 'x (3) 2X4 CORNER STUDS SIMPSON CMDTC I 4 NAILED WITH 5~¢ I ~d SINKER NAILS CORNER STRAPPING DETAIL WHEN TWO STORIES EXIST NO SCALE ,: '3500 LBS SIMPSON HDUS-SDS2.5 HOLDOWN SECURE WITH SCREWS SUPPLIED WITH CONNECTOR 1 ST FLOOR FRAMING FOR RETROFITTING BOLT DRILL HOLE AND APPLY SIMPSON ACRYLIC TIE ADMEADIVE, __ APPLICATION AND PREPORATION A5 PER MANUPACTURES SPECIPICATIONS WALL FRAMING MIN. 3 -STUDS SHEATHING 5ILL PLATE FOUNDATION WALL MOLDOWN DETAIL NO SCALE 7000 LSD NOTE ALL HOLDOWNS AT EXISTING CONSTRUCTION SHALL DE ~NSTALLED FROM THE EXTERIOR OF ~'HE RESIDENCE, DO NOT DISTURB THE INTE~OR FINISHES, CAREFULLY REMOVE THE EX'ISTING MATERIALS'I' INSTALL HOLDOWN AND REINSTALL EXISTING MATERIALS WALL FRAMING SHEATHING NOT SHOWN I ST FLOOR FRAMING SIMPSON FJA FOUNDATION ANCHORS SPACED 46" O.G. SIMPSON MSTA I 8 ~ $2" O.C. NAILED WITH 8- I Od COMMON NAILS TO FLAT,JOIST AND 5- IOa COMMON NAILS TO STUDS ALIGN WITH ANCHORS SIMPSON SS? ~ I G" O.C. NAILEDWITH I - I Od COMMON NAILS TO TSILL PLATE AND 4- I Od COMMON NAILS TO STUDS STUD TO FLOOR TO, FOUNIDATION CONNECTION NO SCALE NOTE FOR CONSTRUCTION WITHIN ONE MILE OF THE SHORE LINE I, CONTRACTOR 15 TO PROVIDE ~" PLYWOOD ?RECUT AND LABELED PANELS FOR ALL GLAZED OPENINGS EXPOSED TO THE WEATHER t General Notes LIST Of= DRAWINGS' A-I GENE NOTES SITE PLAN AND _zONING INFORMATION A-2 FOUNOAaON F:'LAN,SECOND FLOOR' ?LAN~ ROOF ~LAN A-3 F, sT FLOOR 'LAN SECT ON ?LUMIStNG A-4 ELEVATIONS DESIGN DETAIL5 STEPHEN ~IW~N~I A~CMITECT 135 EMO~Y ~OAD MINEOLA, N.Y. (5 I G) 747-I 3G8 ADDITION5 TO T~ CARAWAY R~SI 1350 SMITH DRIVE NORTH , 5OUT~OLD N,Y. A5 NO,ED: OF 5' ,,