Loading...
HomeMy WebLinkAbout34032-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34173 Date: 01/25/10 T~IS u~TIFIES that the building COMMERCIAL STOR. BLDG. Location of Property: 67875 MAIN ROAD GREENPORT (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 52 Block 5 Lot 58.2 Subdivision Filed~4ap No. __ Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JULY 2, 2008 pursuant to which Building Permit No. 34032-Z dated JULY 2, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is COMMERCIAL STORAGE BUILDING FOR CONTRACTOR'S YARD AS APPLIED FOR PER ZBA #4934, DATED 4/19/01. Ge certificate is issued to ALBERTSON LANE LLC (OWNER) of the aforesaid building. ~UF~OLK CO[~l"f DEPAR~I~NT OF ~2%L~{ ;~PPRO~L~L C10-01-0005 04/09/07 RLR,ir~IC~J~ CE~TIFICA~ NO. 4025999 04/24/09 PL~4B~S C~RTIFICATION DA-r~ 01/15/10 JOSEPH WHITECAVAGE Rev. 1/81 Form No. 6 TOWN OF $OUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Location of Property: Old or Pre-existing Building: House No. Street Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Subdivision Permit No. Date. %,q, Health Dept. Approval: fO (check one) Block ,.~ Lot Filed Map. f'2"- ? 7 ? Lot: Applicant: /¢;7//~'/~/X~2,, ~ Date of Permit. t'~,, 2aa"7 / Underwriters Approval: Final Certificate: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ 5''t~. O0 _.Oc (check one) ;~gnature Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York I 1971-0959 Telephone (63 I) 765-1802 Fax (631) 765-9502 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. 3 ~L 0 '3 ~ Owner: }~/~g/~,:- ~4 / {_. ~_~ (Please print) Plumber: ~,o£(~26 ~6,'/r'c~ / (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Sworn to before me this // day of .~-~-,o-~, 20 ~ ~' Notary PU~C~~ County (Plumbers Signature) BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by JIM SAGE ELEC. INC. PO BOX 38 GREENPORT, NY 11944-0038, ALBERTSON LA LLC. ALBERTSON LA GREENPORT, NY 11944 Located at ALBERTSON LA GREENPORT, NY 11944 Application Number: 4025999 Certificate Number: 4025999 Section: Block: Lot: Building Permit: · BDC: ns11 Described as a Commercial occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: First Floor, Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the:z4th Day of Service Service Disconnect: Service3Phase4w Service Ra0ng800Amperes Wiring And Devices Fixture Fixture Receptacle Receptacle Receptacle Receptacle Switch Rate Rating 200 Circuits April, 2009. Ty~e 3 0 Incandescent 5 0 High Intensity 1 0 30a Special / twist lock 1 0 50a Special / twist lock 8 0 GFCI 15 0 Gert, Purpose 5 0 Gen, Purpose I of I seal This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUII~JING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PER~IT NO. 34032 Z Date JULY 2, 2008 Permission is hereby granted to: PAUL J III CORAZZINI 3120 ALBERTSON LA GREENPORT,NY 11944 for : CONSTRUCTION OF NEW COMMERCIAL STORAGE BLDG.FOR A CONTRACTOR'S YP-RD AS PER ZBA, PLANNING& CHAPTER 46 OF TOWN CODE REPLACES BP # 29085 at premises located at County Tax ~ap No. 473889 Section 052 pursuant to application dated JULY Building Inspector to expire on J~N~3ARY Fee $ 1,292.00 67875 MAIN ROAD GREENPORT Block 0005 Lot No. 058.002 2, 2008 and approved by the 2, 2010. ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29085 Z Date JANUARY 8, 2003 Permission is hereby granted to: PAUL J III CORAZZINI 3120 ALBERTSON LA GREENPORT,NY 11944 for : CONSTRUCTION OF A NEW COMMERCIAL STO~AGE BUILDING FOR A CONTRACTOR'S YARD AS PER ZBA, PLAiqNING AND CHAPTER 46 OF THE TOWN CODE at premises located at 67875 MAIN ROAD GREENPORT County Tax Map No. 473889 Section 052 Block 0005 Lot No. 058.002 pursuant to application dated SEPTEMBER 17, 2002 and approved by the Building Inspector to expire on JULY 8, 2004. Fee $ 969.00 ORIGINAL Rev. 5/8/02 765.1802 BUILDING DEPT. [[ ]] ~OR~UMNiDNA~ION 2ND [[ ]] IF~NSAU~'ATION [ ] FIREPLACE&CHIMNEY , INSPECTION [ ] FOUNDATION 1ST [ '] R~OUGH PLBG. INSPECTION [ ]FOUNDATION 1ST [ ] ROUGH PLBG. [ ]FOUNDATION 2ND [ ]INSULATION [ ]FRAMING / STRAPPING [~ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SA~-,-; ~ INSPECTION [ ] RRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: TOWN OF SOUTHOLD BUILDING DEP~ 765-1802 To: Pat Page 2 of 2 2009-12-18 19:26:27 (GMT) 631-614-3516 From: Joseph Fischetti, PE PROFESSIONAL ENGINEER 1725 HOBART ROAD / PO BOX 616 SOUTHOLD, NEW YORK 11971 TEL: 631.765.2954 · FAX: 631.614.3516 · e-mail: joseph~fischetti.com Re~rence: December 18, 2009 Comzzini Bid. / BP ¢h34032Z Southold Building Dept PO Box 1179 Southold, NY 11971 Dear Sir, I inspected the foundation during construction and have recently inspected the structural steel. I certify that to the best of my knowledge, the foundation and the structural steel erection have been COmpleted in acCOrdance with plans submitted for Building Permits and in acCOrdance with New York State Codes BEDG. DEPT. TOWN OF SOUTHOLD PLANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L~ TOWNSEND March 5, 2007 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave. Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD Paul J. Corazzin/, III 3120 Albertson Lane Greenpott, New York 11944 Rel NYS Road 25 & Albertson Lane Greenport, New York SCTM#: 1000-52-5-58.2 Dear Mr. Corazzini: At the written request of Paul J. Corazzini, dated August 1, 2006, requesting final site plan inspection, Planning Department staff performed a final ske visit on February 21, 2007. In reference to the above, the Planning Board has discussed this application at numerous work sessious, most recendy on February 26, 2006, to discuss the approved site plan approved, the as-built site plan with proposed changes made byPaul J. Corazzini date received February 15, 2007 and staff site risk comments. In reference to the above, the Planning Board has determined the site plan requirements have been satisfied and include the following items: The applicant must comply with New York State Code and ADA requirements regarding all handicap parking stalls, access aisles and signage. All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. All lighting must meet town code requirements. The Planning Board approves the reduction of the vegetative buffer fronting NYS Road 25 from 50' to 25' as shown on the approved as-built ske plan/survey prepared by John T. Metzger dated September 21, 2005 and last revised on May 16, 2006 with hand drawn changes byPaul J. Corazzini. As indicated on the plan/survey, the buffer line along the comer of NYS Road 25 and Alberton's Lane measures approximately 100' from the comer property along NYS Road 25 and approximately 100' from the comer along Albertson's Lane, to allow the maximum vegetative buffer possible. Paul J. Cora,'mi Page Two March 5, 2007 · As detailed on the approved as-bnilt site plan/survey, the applicant must maintain the buffer area and replant/vegetate with native species as necessary. The Planning Board approves the relaxation of the buffer area with the understanding that the buffer area must be maintained with substantial vegetation along NYS Road 25 as k is a scenic corridor within the Town. The Planning Board reserves the right to require the installation of additional landscaping/vegetation as required. · In addidon the Planning Board shall not permit the removal of anyvegetadon, storage of any vehicles/equipment or constmcdon of any kind within this buffer area. · All requirements of New York State Department of Tramportadon must be met. Please find enclosed a copy of the approved as-bnilt site plan/survey prepared by John T. Metzger dated September 21, 2005 and last revised on May 16, 2006 with hand drawn changes byPaul J. Corazzlni dated received bythe Planning Department February 15, 2007. This letter does not condone any changes from the as-built site plan and approvals from other agencies if required. Respectfully yours, Chairperson Cc: File Building Department Town Engineer Enc: One (1) copy of the approved as-built site plan/survey prepared by John T. Metzger dated September 21, 2005 and last revised on May 16, 2006 with hand drawn changes by Paul J. Corazzini date received bythe Planning Department February 15, 2007 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined ~' ,~'5~, 20 Approved ~. ~t~ ,20 ~.~ Disappro~/a/c Expffati~ ~ ,20 O ~ BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the followin.~r~efore applying? Board of Health r,-'~"/// 3 sets of Building Plans Planning Board approval '~' Survey ,/ Check -'~ 1').~/ Septic Form ~ N.Y.S.D.E.C. Trustees Contact: Mail to: APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS ,200 a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. , f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new pemait shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (g~ame, if a corporation) (Mailing address ~f applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises /'~a / ~ dO,/~' 2 a ,'v~,' ~' (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: House Number Street County Tax Map No. 1000 Section Subdivision (Name) Hamlet ' ' ' ?.xM '(5" ~{ Fil~ Map NQ. ~t,' : ~t · 0 State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy '/q~Y/~ b. Intended use and occupancy ~]~rSlff/( q ~ r~3l 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Estimated Cost J~O/ r_)OO Fee If dwelling, number of dwelling units If garage, number of cars (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. /'4~0/~ I 7. Dimensions o,f~x~}g structures, if any: Front ~t9 Rear ~d .Depth Height /' · Number of Storie~- Dimensions of same structure with alterations or additions: Front Depth. Height Number of Stories :: 8. Dimensions of entire new construction: Front ~5~(-j~ Rear ~-~O ~ Depth Height / q p r Number of Stories 9. Size oflot: Front '7..$'7 Rear t/~'t'/r ~ _Depth 2~0/ Rear 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO ~ 13. Will lot be re-graded? YES __ NO t~Will excess fill be removed fi.om premises? YES__ NO__ 14. Names of Owner of premises Name of Architect Name of Contractor Address Phone No. Address Phone No Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY B,E~?~.EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) · SS' COUNTY OF 5~ r~oo [IF' ~r4 / ~'~Lg "~' being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the t~p~'~ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of~ 20 O~. (l~otary Public Public, State Of NO. 01MA6065694 ~uallfled In Suffolk County p..omn, dssion Explre~ October 29, Applicant ]~-]~)4~-__~-.-~ --,~, ~. TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET ~:~7 ~-Z~ VILLAGE DIST. SUB. LOT REMARKS TYPEOF BLD. ' / f PROP. CLASS LAND IMP. TOTAL DATE I FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD Z~d ~7 = ~ ~O WOODLAND DEPTH ~ MEADOWLAND BULKHEAD HOUSE/LOT TOTAL COLOR TRIM M. Bldg. Foundation P.c. c.8. Bath Dinette FULL Extension Basement CRAWL Floors Kit. SLAB Extension Ext. Walls Interior Finish L.R. Extension Patio Porch Deck Breezewa Garage Pool Fire Place Dormer Driveway Heat Woodstove Attic Rooms 1st Floor Rooms 2nd Floor BR. Fin. B. PLANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair RICHARD CAGGIANO WILLIAM J. CREMERS KENNETH L. EDWARDS MARTIN H. SIDOR P.O. Box 1179 Town Hall, 53095 State Route 25 Southold, New York 11971-0959 Telephone (631) 765-1938 Fax (631) 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM Amended 17 Date: March 17, 2004 To: From: Re: Michael Verity, Principal Building Inspector Jerilyn B. Woodhouse, Planning Board Chair(~ Unauthorized Site Plan Activity Paul Corazzini 3120 Albertson Lane Greenport, NY SCTM# 1000-52-5-58.2 Status: Site plan approved 09/30/02 with open building permit 29085z A site inspection by Planning Board Staff on March 5, 2004 and March 11, 2004 revealed major clearing and removal of vegetation within the prescribed buffer zones indicated on the approved site plan. In reference to the above, attached you will find a copy of the BP# 29085z which indicates "as per ZBA, Planning". On March 11,2004 Mr. Paul Corazzini came into the P.B. office and indicated that he will submit a letter of intent and landscape Site plan detailing the changes. Until the amended site plan is reviewed and accepted by the Planning Board, this site is in violation of an approved site plan. We formally request that the Building Department don't issue the certificate of occupancy until the applicant comes in full compliance with the site plan requirements. Thank you in advance. cc: file, ef, ta Eric.: letter PLANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair RICHARD CAGGIANO WILLIAM J. CREMERS KENNETH L. EDWARDS MARTIN H. SIDOR P.O. Box 1179 Town Hall, 53095 State Route 25 Southold, New York 11971-0959 Telephone (631) 765-1938 Fax (631) 765-3136 MEMORANDUM Date: To: From: Re: PLANNING BOARD OFFICE TOWN OF SOUTHOLD March 15, 2004 Michael Verity, Principal Building Inspector Jerilyn B. Woodhouse, Planning Board Chair ~ Unauthorized Site Plan Activity Paul Corazzini 3120 Albertson Lane Greenport, NY SCTM# 10 -5~.2 ~..~- 172OO4 Status: Site plan approved 09/30/02 with open building permit 29085z A site inspection by Planning Board Staff on March 5, 2004 and March 11,2004 revealed major clearing and removal of vegetation within the prescribed buffer zones indicated on the approved site plan. In reference to the above, attached you will find a copy of the BP# 29085z which indicates "as per ZBA, Planning". On March 11, 2004 Mr. Paul Corazzini came into the P.B. office and indicated that he will submit a letter of intent and landscape site plan detailing the changes. Until the amended site plan is reviewed and accepted by the Planning Board, this site is in violation of an approved site plan. We formally request that the Building Department don't issue the certificate of occupancy until the applicant comes in full compliance with the site plan requirements. Thank you in advance. cc: file, ef, ta Enc.: letter PLANNING BOARD MEMBERS BENNETT ORLOWSKI, JR. Chairman RICHARD CAGGIANO VglLLIAM J. CREMERS KENNETH L. EDWARDS MARTIN SIDOR P.O. Box 1179 Town Hall, 53095 State Route 25 Southold, New York 11971-0959 Telephone (631) 765-1938 Fax (631) 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM T: Michael Verity, Principal Building Inspector F: Scott Hughes, Senior E~n~er~' R: ML"~a~hine and Equipment Re~aul Corazzini SCTM: 1000-52-5-58.2 17 September 2002 D: On November 5th, 2001 the Planning Board granted this project Conditional Final Approval requiring "Approval by the Suffolk County Department of Health Services". This condition has been fulfilled by the submission of Health Department stamped maps, one of which I attach for your files. Enc. Site Plan erard P, G0ehringer' Chairman - James Dinizio, Jr. Lydia A. Tortora Lora S. Collins George Homing BOARD OF APPEALS TOWN OF SOUTHOLD Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, New York 11971 ZBA Fax (631) 765-9064 Telephone (631) 765-1809 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF APRIL 19, 2001 Appl. No. 4934- PAUL J. CORAZZINI Location of Property: 67876 Main Road, Greenport Date of Public Heating: April 5, 2001 Parcel 1000-52-5-58.2 FINDINGS OF FACT PROPERTY FACTS/DESCRIPTION: The subject property is a 1.0475-acre lot located on the comer of the Main Road (S.R. 25) and Albertson's Lane, Greenport. The lot has two read frontages, one of 287.17 feet along Albertson Lane and 260 ft. along the Main Road. The property is located in the LI Light Industrial Zone District. .BASIS OF APPEAL Building Inspector's Notice of Disapproval dated December 18, 2000, denying an application dated November 13, 2000 for a permit to build a commemial building, for the following reasons: (1) Article XIV, Section 100-142 requires 70 ft. minimum rear yard setback, and (2) Article XIV, Section 100-143C for the reason that "no single structure shall have more than sixty (60) linear feet of frontage on one street. An amended Apdl 4, 20001 Notice of Disapproval was issued replacing the above Notice of Disapproval, which negates the necessity for a variance under Section 100-143C as to a building frontage limitation, based on Appeal/Interpretation No. 4708 rendered by the ZBA 7/22/99. RELIEF REQUESTED: Applicant requests a vadance to locate an 40x80 ft. storage building with a rear yard setback at 52 feet, instead of 70 feet, as shown on the November 7, 2000 site plan map. .REASONS FOR BOARD ACTION, DESCRIBED BELOW: On the basis of testimony presented, materials submitted and personal inspection, the Board makes the following findings: 1. Grant of the area vadance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties because, when considering the nature of applicant's business and the size of the trucks and equipment that the applicant intends to store and work on within the proposed building, a 40x80 ft. building is the minimum size to allow adequate room. The building is proposed at the center of the lot and will be screened from the road. The immediate neighboring properties are other industrial zoned uses. 2. The benefit sought cannot be achieved by some method, feasible for the applicant to pursue other than an area variance. The lot is a corner lot with two front yards (100 ft. and 77 ft.). 3. The area variance is not substantial. 4. No evidence has been submitted to indicate an adverse effect or impact on the physical or environmental conditions in the neighborhood or district. The buildingwould be built observing the 100 ff. front yard setback ,with a 50 ff. natural buffer along the Main Road, thereby shielding it from ZBA Appl; No. 4934- P. J. Corazzini Re: 1000-52-5-58.2 at Greenport view from most of the traffic passing by; the 77 ft. front yard setback off Albertson Lane with a natural buffer area also shields visibility of the industrial use at the property. 5. The action set forth below is the minimum necessary and at the same time preserves and protects the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION: On moti0n by Member Dinizio, seconded by Chairman Goehringer, it was RESOLVED, to GRANT approval of a setback not less than 52 feet from the rear property line, as applied for. VOTE OF THE BOARD: AYES: Members Goehdnger (Cha~jcma,~, Dinizio, Tortora, Collins, and HOming. This Resolution was duly ado pt e d (5- 0)~.....~../...~~~ .,,,~E'RARD P. 'GOEHRINGE'R " . f CHAIRMAN FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPAKTMENT SOUTHOLD, N.Y. AMENDED NOTICE OF DISAPPROVAL DATE; April 4, 2001 TO Joseph Fischetti A/C Corazzkfi .P.O Box 6t6 So,uthold,NY 11971 PleaSe take notice that your application dated November 13, 2000 For permit for commercial storage building Location of property _.67875 Main Road Greenport NY County Tax Map No. 1000 - Section 52 Block5 Lot 58.2 Subdivision Filed Map # Lot # Is returned herewith and disapproved on the following grounds Proposed 1)roiect not permitted pursuant to Axfcle XIV Section 100-142 winch states; No building or prem(ses shall be used and no building or part thereof shall be erected or altered in the I2[ Light Industrial District unless the same conforms to the BuLk Schedule and parking anti Loadin E Schedules incorporated into this chapter by reference, with the same force and effect ~ if such regulations were set forth herein in full. B__ulk .schedule requires 70 (seventy) foot rear yard setback, proposed structure shown at 52 (fifty two) feet from rear lot line. Proposed, Proiect not permitted pursuant to ~4rtt'cle XIV Section 100-143C which states; ~4 pro[ect shall be divided into:sepamtte structures so that no single structure shall have more. than sixty (60):linear feet lO f frontage on one (1) streea The setbacks of multiple structures on a parcel ma~ var),~ provided that the average setback of the structures meets the setback required above and all buildlnes are,at [east seventF-five (75) feet from the rlght-of-waF. ProlJoSed structure has 80 (eighty) foot frontaee on Main Rong The above.italicized p~rtioa of this disapproval is being removed pursuant to Appeal # 4708 dated 7/22/99 which interpreted Section 100-143c~ negating the necessity for a variance_an FORM NO. 3 TOWN OF SOLrrHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE 01~ DISAPPROVAL DATE; December I8, 2000 TO Joseph Fisaheifi gYC Corazziui PO'Box 6t6 SouthoidNy 11971 Please tak~ notice that your application dated November 13, 2000 For pennit f~ commercial, storag9 building at Loeationofprope~ty 6?875 MainRoad C, vteenpor~NY CountyTaxMap No. 1000- Section 52 Block5 Lot 58.2 Subdivision Filed Map # Lot # Is returned herewith and disapproved on the following grounds Proposed ~roieet not permitted pursuan, [o Ax~ticle XIV Section 100-142 which states; No buildinlg:or prennsas shall be used and no building or part thereof shall be meted or altered in the LI Liv2tt Industrial District unless the same conforms to thc Bulk Schedule and Parkin~ and Loading Schedules incoreorated into this chapter by reference, with the same force and effect as if such regulations were set forth herein in full. Bulk schedule requires 70 (seventy} foot rear yard setback, proposed slranture shown at 52 (fifty t~vo) feet from rear lot line. Pmnosed ~roiect not permitted pursuant to Article XIV Section 100-143C which states; A proiect shall be divided into separate structures so that n~ single structure shall have more than sixt~ (60} linear feet of frontage on one (1) s~reet. The setbacks of multiole structures on a ~arcel may van,. provided that the avemee setback of the sh'uctures meets the sothaek requixed above and all builain~ are at least ¢;~v~mtv-five (77) feet fi'om the ril;cht--of-wa¥. Prot~oscd structure has 80 (ci~htvl foot frontage on Main Heritage Building Systems P.O. Box 470 North Little Rock, Arkansas 72115 501-945-3377 December 18, 2002 Job #NYX19110 P.J. Corriziui Greensport, New York New York State Building Code Use and Occupancy Classification Group C4,2 low hazard storage as defined in section 703.5 Type 2b - noncombustible construction 2093 Cherry Road Cabot, Arkansas72023 501-843-9790 New York PE # 069093-1 Type ofConstmcfion tablelH-704 PLANNING BOARD MF..,MBEI:t8 JERILT'N B. WOODHOUSE Chsi~ RIOI-IARD CAGGIANO KEITI~TH L. EDWARDS MARTII~ H. SIDOR P.O. BOX 1179 Tovm Hall, 58095 State Route 25 Southold, New Y~rk 11971-0959 Telephone (651) 765.19~S F,-~ (681) 76~-~136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM Amended Date: March 17, 2004 To: From: Re: Michael Verity, Principal Building Inspector Jerilyn B, Woodhouse, Planning Board Chalr~) Unauthorized Site Plan Actl~,ity Paul Comzzini 3120 Albertaon Lane Gmenport, NY SCTM# 1000-52-5-58,2 Status: Site plan approved 0g/30/02 with open building permit 29085z A site inspection by Planning Board Staff on March 5, 2004 and March 11, 2004 revealed major clearing and removal of vegetation within the prescribed buffer zones Indicated on the approved site plan/In reference to the above, attached you will find a copy of the BP# 29085z which indicates "as per ZBA, Planning". On March 11,2004 Mr. Paul Corezzlni came into the P.B. office and indicated that he will submit a letter of intent and landscape ~ite plan detailing the changes. Until the amended site plan Is reviewed and accepted by the Planning Board, this site is in violation of an approved site plan. W.e fore, ally request that the Building Depa~[[hent don't issue the certificate of oc. cupancy until the applicant comes in full compliance with the site plan requirements. Thank you in advance. cc: file, ef, ta Enc.: letter · . ,~d~4'~H T. T.EI~.RY TOW~ C LEI"~K OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 2~, 1993: RESOLVED that the Town Board of the Town of Southold hereby adopts two (2) new forms to be used under tFte Flood Damage Prevent regulations of the Code of the Town of Southold: "Floodplain Developmen.t Permit Application" [FDP(93)], and "Certificate of Compliance for Development in Special Flood Hazard Area [C/C(93)]. Iff'? ; TOWN OF SO.:J~OLD [ . Terry o' Southold Town Clerk August 25, 1993 APPLICATION # PAGE I of 4 TOWN OF SOUTHOLD FLOODPLAIN DEVELOPMENT PERMVI' APPLICATION This form is to be filled out in duplicate. SECTION 1: GENERAL PROVISIONS (APPLICANT lo read and 1. No work may start until a permit is Lxsucd. 2. Thc permit may be revoked ff any fal~e statemcnl-S arc made herein. 3. If revoked, all work must ceuse until permit is re-issued. 4. Development shall not be used or occupied uadl a Certificate of CompLiznce is issued. 5. The permit will expire il' hO work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local, state mad federal regulatory requirements. 7. Applicant hereby gjve~ con.seat to the Local Administrator or his/her rcpre.~eatative to make reasonable iuspecfiot~ requited to verify compllaucc. _ THIS APPLICATION ARE, TO THE.J3F:~/9~jMY KNOWLEDGE, TRUE AND ACCU~d~.-] (APPL~CAN'PS S ) / SECTION 2: PROPOSED DEVELOPMENT (To Ipe completed by APPLICANT} NAME ADDRESS TELEPHONE To avoid delay in proce~ing the appllcadou, please provide cnou_v.h information to ea.~ily identify the project location. Provide the street ,ddress, lot number or legal description (attach) and, outside urban arm, the distance to the nearest intersecting road or weLl-known l~dmark. A sketch attached to this application showing the project location would be helpOaL FDP(93) · " APPLICATION pAGE 2 OF ~ DESCRIPTION OF' WORK (Check all applicable boxes) A STRUCFURAI~ DEVELOPMENT ACTIVTrY ~New Structure [3 Addition [] Ahcration [] Rclocatlon [] Demolition [] Replacement .STRUCTURE TYPE Fl Residential (1~ Family) N[~ouff] Residential (More tha~ 4 Family) residential (Floodprool-mg? [] Yes) [] Combhaed Use ('Residential &Com. mercLal) [] Manufactured (Mobile) Home (In Manu- factured Home Park.'? [3 Ye-s) ESTIMATED COST OF PROJECT B. OTHER DEVELOPMENT ACWIVITIES: [] Fill [] Mining [] Drilling [] Grading E] Excavation (Except for Struciural Development Checked Above) - [] Watercourse Alteration (Including Dredging and Channel Modifications) [] Drahaage Improvemem-~ (Including Culverl Work) [] Road, Street or Bridge Coastruction [] Subdivision (New or Expansion) [] Individual Water or Sewer System / ~/~ [3 Other (Please Specify) ff"O~ ~ Ia~- / ('~ ' After completing SECTION 2. APPLICANT should submit form to Local Admlaxistrator for review. ~ECTION 3: FLOODPLAIN DETERMINATION (To be completed bv LOCAL ADbIINISTRATOR) The proposed development is located on FIRM Panel No. , Dated The Proposed Develgpment: ~NOT located in a Special Flood HaTard A~ea (']qOtif~ the applicant that the application rex4ew i~ complete and NO FLOODPI--'adN DEVELOPMENT pERlvlTr IS REQUIRED). F1 Is located in a Special Flood Hazard Area. IqRM zone designation is tOO-Year flood elevation at the site is: Ft. NGVD (MSL) [2 Unavailable [] Thc proposed development is located in a floodway. FBFM Pazml No. Dated [] Sec Sec~o~~. itional instructions. A~PLICAT1ON # -- PAGE 3 OF 4 SECTION_4: ADDITIONAL INFORj'vIATION REQUIRED (To hc completed bv LO~CA2L ADMINISTRATOR] The appticant must submit the documents checked below before the application can be proc~scd: [] A site plan showing thc location of all existing structures, water bodies, adj~ccm roads, lot dimensions and proposed development. [] Development plans, drawn to scale, and specifications, including where appticablc: details I'or anchoring structure, proposed elevation of lowest floor (including basement), types of water resistant materials used below the first floor, details of floodproofmg of utilities located below the £trst floor and details of enclostLres below the first floor. A~o, E] Subdivision or other development plans (If thc subdivision or other development exceeds 50 lots or $ acres, whichever is the lesser, the applicant must provide 100-year flood elevations if they are not otherwise available). I"l Plans showing the extent of wat~rcourse relocation a.nd/or lanctform alterations. [] Top of new l'tl} elevation Ft. NGVD (MSL). El Floodproofing protex:tion level (non-residential only) Ft.' NGVD (M-RL). For floodproofed structures, applicant must attach certification from registered engineer or architect. [] Certification from a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of the 100-year flood. A copy of all data and c~cnlations supporting this finding must also be submitted. [] Other. ~E~-'TION 5: PERMIT DETERMINATION (TO be completed bY LOCAL ADMINI~'TRATQR) I have determined that the proposed activity, ,6_ I-1 Is B. 1~ Is not in conformance with provisions of Local Law g , 19 . The Ix:mit is issued subject to the conditions attached to and mada part of this p~rmit. SIGNED . DATE I~BOX A is checked, the Local Administrator may issue a Development Permit upon payment of designated fee. If BOX B is checked, the Local Administrator xvill provide a written summm'y of deficiencies. Applicant may ~evise and resubmit an apptication to the Local Administrator or may request a bearing from the Boa.rd of Appeals. AppELA]~: Appealed to Boa~rd of Appeals? O Yes [Z} No H ca~-mg dale: Appeals Board DecLsion -- Approved? [] Yes Conditions [] No APPLICATION PAGE 4 OF 4 ~E(TFION 6: A.5-BUILT ELEVATIONS (To be submitted by APPLICANT before Certificate 0f Compliance i~ issued'l The following information mttst be provided for project structures. Thks section mnst be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete 1 or 2 below. 1. Actual (A~-Built) Elevation of the top of ~he lowest floor, indudlng basement (in Coastal High Hazard Areas. bottom of lowest structural member of the lowest floor, exdudlng piling and columns) is: FT. NGVD (MSL). 2. Actual (As-Built) Elevation of flocMproo£mg protection is FT. NGVD (MSL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. ~ECTION 7: COMPLIANCE ACTION (To be completed bv LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSP~C"FIONS: DATE BY DEIqCI~NCIES? [] YES r-I NO DATE BY DF..FICIENCIES? [] YES [] NO DATE BY DEFICIENCIES7 U] YES [] NO SECTION $: CERTIFICATE OF COMPLIANCE(To be comt~leted by LOCAL ADMINIb~TRATOR~ Certificate of Compliance issued: DATE: BY:. Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HAXAJLD AREA (o~rNER MUST RETAIN THIS CERTIFICATE) PR~MISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: F1 NEW BUILDING [~ EXISTING BUILDING U] VACANT LAND THE LOCAL ADMINISTIL, kTOR IS TO COMPLETE A~ OR B. BELOW: COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # ,19 SIGNED: DATED: COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19__, AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: C/C(93) Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 09/17/02 Transaction(s): Septic Permit - Construct. Non-resid. Receipt#: 0 Subtotal $25.00 Total Paid: $25.00 Name: Corazzini Iii, Paul & Ruthanne 3120 Albertson Lane Greenport, NY 11944 Clerk ID: LBOHN Internal ID: 62553 AREA=I.0475 ACRES -O-=UTT. LZTY POL£ ALBERTSON'S i ~Joj~ SCDHS Ref. ~ C10-01-0005 SURVEY OF PROPERTY A T GREENPORT TOWN OF SOUTHOLD SUFFOLK COUNTY,N.Y. 1000-52-05-58.2 SCALE.: 1'--20' SEPTEMBER 21, 2005 Feb. IQ, 2oos [£L£VA TION$.~ MA.Y lB,, £DOS(FIN,4L) LANE $ 87'a4 '3~' E LP 125,0 $OU TH OLD, KEY MAP $CALE:i '=600 ' ET .~, 99-272 SUFFOLK COUNTY DEPT. OF HEALTH SERVICES, CALL 852-2097, 48 HOURS IN ADVANCE, TO SCHEDULE INSPECTION(S). SUFFOLK COUNTY DEPARTMENT OF HEAL1H 8EflVICE APPROVED FOR CONSTRUCTION ONLY H.S. REF.NO. Cfc- 0/-0005' FLOW TYPE., ~'fo ~ ~ Thio approval ia granted for the conslru~oo ~1 Ihe ssnila¢/ disposal and watar supply facilities pumuant to Art~ales VD ? cf the Saffalk County Sanitary Code and is not an ~-r Implied approval to ~ischargo from or occupy the stmctura(s) show'm 'THIS APPROVAL EXPIRES THREE YEARS FROM THE DATE BELOW. DATE SIGNATURE ~JSJECT TO CONVENANT8 & REErRICTIONB iJ P~E LB~R ~"SON' $ V,4C~IT .<:~=U TIL Z T Y AREA LANE ~ ~o' .~ ~ KEY MAP $CALE~i ~=600' SITE' PLAN.'FOR PAUL CORAZZINI .! A T GREENPORi' TO WN OF SO UTHO D SUFFOLK COUNTY , N. Y. 1000-52-05-58.2 SCALE: 1" =20' APPROVED BY PLANNING BOARD TOWN OF SOUTHOLD DATE'~ ?~ o~ JUNE 8~ 2000 .Nov. 7, 2000 (rev/sionl FEB. 14, ~001 APRIL 13~ gO01 ( revision ) MA Y $0~ 2001 ( revl$1o~ ) ~' ~o- ] S 87'24'30' g .~'t~ ~ r ~.vMm I · ~8. X4' ~ ~ SUb.ACE SEWIGE DISPOSAL ~ ~5' B U F F E R ~ rein ~l~ SYST~ DESI6N ' ~ ....... ~ART RO~D ~ ~ ~ ~OUTHOLD~ ~.y. ll971 . it " / / ' " % ¢ ~ ~ 320~./t 000 = ' spaces ~ .~ ,f PROV,~ED - I GROUND WA TER MANAEMENT ZONE' IV ' ALLOWABLE FLOW FOR SITE~ 600 gp8. --~' ' 600 ~d / s.f. x 1.04Z~ ACRES = 698.5' ~d., SEWAGE DISPOSAi . ~ ~ · ~,,~ DRAINAGE: STORAGE BUILDING (ANDUSTRIAL) ~ ~ .~ I ' 0.17 x 3200 = 544 cu. ft. BLUESTONE PARKING ~ DR/VEWAY SEWAGE DISPOSAL SYSTEM DESIGN' ~ ~ 77~0 sq. ft. SEPTIC TANK ~ 0.5 ~ 0./7~ 77~0 = 656 cu. fl. / ' ~ ~ PROPOSED, 1~8 9pd 2 = ~5~ GPD /~oo cu. ,. I ' PROVe, MINIMUM SYSTE~. ;900 ~n ~ use I~ ' / ~'~~ J /~00/~2.2 = ~8.~ VF. , LE~cHm~ POOLS ~ PROVIDE ~ L.P.S ~'~ ~' Dee~ 3 L.P. ~ ~' ~ ~ / REOUIRED. 1~8 ~ 1.5 . 85 s.f. leocei~ aMo ~Or~ ~o ~' / LIGHTING PROVIOE, ~IUUU 300 ~.1. I. ocM. g ~4e~4o'- I = SHIELDED FLOODS HR5 - Max Height 14' 4~ ~ // ~= Proposed E/e.vo//ons APPLICANT' / PAUL CORAZZINI ae ~0~ O~ ' "' 31~0 ALBER[SON LANE / ¢ LOT COVERAGE ~ c ~ ~ t GREENPOR T, N. Y. ~o ,CONTO~ L~E A~ ELEVA T~ A~ ~FE~ED ~' ~. ~5 BUILDING - TO FIVE EASTERN TO~ T~A~ MAP '~ - LANDSCAPIN~ ~ BUFFER ..... . ANY ALTE~AT[DN D~ A~DIT[DN TD THIS SURVEY IS g VIDLATIUN ,~, ~IC, ~D, 4961~ ~¢~/~¢ '"?, '"~,*- ,~ DF SECTIDN 7B09 DF THE NEV YDRK STATE EflgCATIDN ,' ~ PHONE ~-,..,- ~. - EXCEPT AS PER SECTIDN 78,09 ~UBDIV~SIDN ~. ~ALL CERTIFICATIDNS "' '""¢ HEREDN ARE VALID FOR THIS HAP AND CDPIES ',THEREDF ~NLY ~F ~:,, : , P,D,B~ 1 0475 '' acres ,, .~ ~r ~' ~,- SAIB..HAP DR CDPIES .BEA~ THE IMPRESSED SEAL EF THE SURVEYflR i230 TRAVELER STREET . ' WHDSE SIGNATURE APPEARS HEREDN. SDUTH~LD, N,Y, SITE DA TA SITE ARI~_A, 1.0475 ACRAE$ ,. TOTAL BUILDING AREA' ~ ~ ' - , f . ALLO'WAB~, '" ' g SANIT~EY FLOW ( DENS~TY ) ', "'" . 3 ,, P,C, 50~0 FAX,'(631) 765-179 k APPLICANT, PAUL CORAZZINI .31,~0 ALBERF$ON LANE GRE£NPOR T, N. Y. ?-=UTILITY PDL£ 'AREA ¸1' VACANT ALBERT$ON'$ S 87°84,30· E 887,17' ' [~' JU# ! 3 2001 Southold Town Planning Board SITE PLAN,FOR PAUb CORAZZIN! A T GREENPORT OF SOUTHOLD ,N.Y TO WN SUFFOLK COUNTY 1000-52-05-58.2 SCALE.'1" =20' dUNE 8~ 2000 .Nov. 7~ 2000 (rev/sion) FEB. 14~ gOO/ APRIL 13, SO01 I revision ) MA Y $0~ 2001 I reV/Wec ) = J F NO TE' SUBSURFACE SEwagE DISPOSAL SYSTEM DESigN JOSEPH FISCHETTI, P.E. HOBART ROAD SOUTHOLD, N.Y~ 11971 16311 765 - 2954 , THERE ARE NO WELLS WITHIN 150' OF SEPTIC SYSTEM THERE ARE NO CESSPOOLS WITHIN 150' OF WELL THERE ARE NO DRAINS WITHIN ~' OF WELL ;T. RJCT: LI FIRE DISTRICI~ $~. SCHOOL DIS TRIC T. 10.5 PARKING - IflO0~ sq. fl. STORAGE BUILDING 40'x 80' =, 3~00 3200/1000 = 3.2 spoCes PROVIDED - 5 i. 04'75 'acres DRAINA GE ,, "ROOF., 3~EO0 sq. fL I ,'x 0.17 x 3200 = 544 cu, ft. , BLUESTONEPARK/NG & DR/VEWAY 7730 ~q. ft. 0.5 ~ 0./7~ 7730 := 6,56 cu. ft. 1200 cu. ft. · IL~00142.2 = 28.4 VF. PROVIDE 6 L.P.S 8'¢ 4' Deep Z, L.P. 8'¢ 2' 'Deep LIGHTING ': '" %SHIELDED FLOODS HP5 - Max , .~I= Proposed Elevations ro ~ ~s~ r~ r~,~ ~ Neigh/ 14'. KEY MAP SCALEd'=600' ~ANITARY DESIGN SITE DA TA ' SITE AREA 1.0475 ACRAES TOTAL ~UILDING AREA, EXISTIN6, O' PROPOSED' $~200 ~.f. S~NITARC DESIGN ~d GPO 3~00 s.L .O~:~d ?s.f. = 1~8 ALLOWABLE SANITARY FLOW ( DENSIT~Y') GROUND WA TER MANAGMENT ZONE' ALLOWABLE FLOW FOR SITE' 300 gpd. f no:public wrier 300 ~Pd / $;f. x h0475 ACRES = 31~,~5 ,gpd.., SEWAGE DISPOSAL S,YSTEM D[StGN CAL,~ULATt~NS, '. STORAGE BUILDING f,INDUSTRIAL ) 3~00 SEWAGE DISPOSAL SYSTEM DESIGN, SEPTIC TANK PROPOSED~ lES ~pd n ~ = ~56 DPD PROVUE' MINIMUM SYSTEMS. 900 ~llec leak use I000 ge/, Caflk LEACHING POOLS REQUIRED~ Iff8 * 1.5 ~ 85 s.I. leeching ergo PROVIDE, M~VIMUM 300 s.f. leeching aree (DIES, P,C, PHDNE:(531). 765 - 50BO P, D, BGX 909 iBSO' TRAVELER STR£ET SDUTHDI_D~ N,Y, 119; ND, 4961,9 FAX¢(631> ANY ALTERATION OR ADDITION TD TH~S SURVEY IS A VIOLATION DF SECTION 7209 DF THE NEW YORK STATE EDUCATION LAW, EXCEPT AS PER SECTION 7209-SUBJ?~V~SION 2, ALL CERTIFICATIONS HEREON ARE VALID FOR TH~S MAP ;~ND COPIES THEREOF ONLY IF SA~,~MAP ~R ~DP~ES .BEAR THE IMPRESSED SE~L DF THE SURVEYDR ~HBSE SIGNATURE APPEARS HEREGN, 765~179: ~ A£B~RT$ON'$ IV. 87%P~'2O" F. ,' APPLICANT, PAUL CORAZZINI 3120 A£BER T$ON LANE xGREENPORT, N. Y. -o-=U,TILITY PETLE AREA ,. , aoFes V.~CANT 15' UT~ITY EASEMENT 25' B U'F F E' R lo 50' ~,DE ~ eB7,iT, remoin oalural .¢ ,f SITE PLAN' FOR PAUL, CORAZZINI AT GREENPORT " TOWN OF S O UTHO' ,D SUFFOLK COUNTY , N. Y ooo-52-o5-58.2 JUNE 8, 2000 .Nov. 7, 2000 (revision) FEB. 14, 2001 APRIL I$, 2001 I revl$ten ) MAY $0~ 2OOI (.revlMen ] DEC. 18, 2002IFLOOD.ZON£S) "D/STRICT..- LI ~'~DISTRIC. T: 31 ~OL. D/STRICT: 10:5 ~, SURFACE SEWAGE DISPOSAL · SYSTEM DESIGN BY' JOSEPH FISCHETTI, P.E. SANITARY DESt~N SITE ~,4 TA SITE ARI~.A 1.0475 ACRA'ES TOTAL BUILDING AREA, · ENOUNO WA TER MANAGMEN:T ZoNE~ IV' ALLO~ABLE FLOW FOR SITE, ~00 600 gpd I s.f; ~ h0475 ACRES = 6~8.5' gpd, LOT COVERAGE DRAI~,~E , "~OOF. ' $~00 sq. fL I ~ 0~]7 ~ 3200 = 544 rCU. fl. ~BLUESTONE PARKING & DRIVEWAY ~7~0' Jq' It' : ' Q'5 ~ O.17X ~730 '~ ~06 cu'fL 1200, cu. fl; I200/42:2 = 28.4 VF.' PROVIDE 6 L,P,S 8'¢ 4' Deep LI~H.~r~G r ~E~AGE DISPOSAL CAL r STORAGE BUILDING (.INDOSTRI~L ) SAN/ 3200 s.f. ' 3200 s,'f.,~ .~4' SEWAGE DISPOSAL S~ YSTEM DESIGN',, SEPTIC TANK ,' · PROVe, 300 s.[. leacbln~ afea .... .. ~-~'r r = SHIELDED 'FLOODS HP5 .- ~--~' Proposed E/eva/ions 3 L.P. 8'¢ 2' Deep Max He/gM IZt" ' FL ODD ZONES FROM FIRM 36103C0159 , ,,~ ~,~' ~o~/~ G 5/04/98 ANY ALTERAT~Ei~ [~I~ A..D.~,I?IIJN TI] THfS SURVEY IS A V£I]LATIDN DF SECT~DN 720:9 DF THE NE~ YDRK. STATE EDUCATIGN LA~/, ' EXCEPT 'AS PER ,¢EETZ'DN 7209-SUBJ?[V¢SIl]N 2, ALL CERTIFICATIDN'S' 'HEIEEDN ARE V/~LID ~DR THIS-MAP ~ND CDPIES TH'EREDF DNLY IF SA!B'~MAP I]R CDPtES .BEAR THE ZMPRESSED SEAL DF -THESURVEYDR ~./HI]SE SZGNAT. URE APPEARS. HERE~N, PHDN£/ P, D, BDX 909 1230 'TRAVELER SDUTHDLD, N,Y; 55 - S TRE£ T ' LI i'_,1 I/4I' :11 BUILDING PO SYSTEMS BOX 47O NORTH LITTI ROCK, AR 72115 ESUILE $PEQIFIC TION$ THE STRUCTURE UNDER THIS CONTRACT HAS BEEN DESIGNED ,4ND DETAILED FOR THE LOADS AND CONDITION5 STIPULATED IN THE CONTRACT AN~ 5HORN ON TN~5~ COMPONENT pA~TS, O~ T~E ADDITION OF OT~E~ CONSTRUCTION MATE~IAL50~ LOAD$ MUST ~E DONE UNDE~ TNB ~OvlOE OF ~ ~E~I$TE~ED A~CNITECT, CIVIL ~IL[TY FOR ANY LOAD5 NOT INOIOATEO. THIS HERITAGE METAL ~UILDING IS DESIGNED USING STANDARZ; DESIGN pRACTICES ~ASED oN PERTINENT PROCEDURES ~N~ ~ECOMMEN~ATION5 OF THE FOLLO~IN~ O~GANIZATION5 AN~ AMERICAN INSTITUTE OF STEEL CONSTRUCTION~ "SPECIFICATiOH FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR ~UILDINGS", 5TH EDITION. AMERICAN IRON AND STEEL INSTITUTE: "SPECIFICATION FOR THE AMERICAN LUELDING SOCIETY: "STRUCTURAL LUELDING CODE" AL~S 0U-88, SECT. 5, PART t~. DESIGN OF ENGINEERED OR DO NOT PROCEED WITH FRAMING UNTIL SURVEY OF FOUNDATION LOCATION HAS BEEN API~ROV_ED. UNDE~NRITERS CERT~I~ REQUIRED PLUMBING ALL PLUMBING WASTE & WATER LINES NEED ~BTING BEFORE COVERING TH LONG OCCUPANCY OR APpm 'D AS.Om .OT, .U,LD,.G ?es-lao:l S AM TO 4 P~/'FOR THE FOLLOWING INSPECTIONS: 1, FOUNDATION - TWO REQblRED FOR POURED CONCRETE ROUGH - FRAMING & PLUMBING INSULATION & FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE N.Y. 6TATS CONSTRUCTION & ENERGY CODES, NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERROR6 RUN MATERJAL pROPERTIES OF STEEL PLATE AND SHEET STEEL USED IN THE FABRICATION OF pRll"IARY RIGID FRAMES AND ALL PRIMARY STRUCTURAL Ff~AMING MEMBERS (OTHER THAN COLD FORMED SECTIONS) CONFORM TO ASTM A-56 MODIFIED ~ITH A MINIMUM YIELD OF 5®,¢®® PSI, OR A-5'l¢ OR MATERIAL PROPERTIES OF COLD FOP-J"IED LIGHT GAGE STEEL MEMDERS CONFORM TO THE REQUIREMENTS OF ASTM-~IO, LLJITH A MINIbIL]M YIELD OF 55,C~C~C) PSI. HIGH STRENGT,-I ~OLTS AND THEIR INSTALLATION SHALL CONFORM TO ASTM SPECIFICATIONS A-~25 AND AP-.~ DESIGNED AS BEARING TYPE CONNECTIONS UJITH THREADS INCLUDED IN THE SHEAR PLANE. TIGHTENING OF THESE I~,OLTS IS REcoMMENDED ~"T' TNB TURN-OF-THE-NUT METHOD, PER "AISC SPECIFICATIONS FOl~ STRUCTURAL. JOINTS." ALL STEEL MEMBERS EXCEPT BOLTS AND FASTENERS SHALL RECEIve ONE SHOP COAT OF rNHIBITIVE PRIMER UNLESS STATED OTHERLUISE IN THE CONTRACT. co~Pt.YWrm c~,~-'R"46" $OUTHOLD' TOWN COD~. USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY If copper tubing ts used for water distributing ~ystem; piping shall be of lypes K or L only/ PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY SHOP AND FIELD INSPECTIONS AND ASSOCIATED FEES ARE THE P-.ESPONSIBILITY OF THE cONTRACTOR, UNLESS STIPULATED OTHERWISE. SOLDER USED IN WATER SUPPLY SYSTEM CANNOT "-¥r'ppn 9/10 OF 1% LEAD. LSI ILITIES Z)ESIG, N LO ING LUING INE)E× &L5 ~N~ PE~IT5 F~OM TNB THIS STrUCTUre 15 ~ESI~NED UTILIZIN~ TNB LOA~5 ~1 of ~ ~NCNOR BOLT PLAN [N~IC~TE~ AN~ APPLIED ~5 ~QU!~D CALCULATION5 INDICATE5 TWE ~UILDE~ 15 TO OONF[~ THAT TMESE LO,DS 5T2 of a LE~T END,ALL ~E STrUCTUrAL STEEL PLAN5 AND THE CO~PLT ~ITM TNE ~UI~ENT5 OF THE LOCAL PLANS ~ILL ~OVE~. (SECT. 3~ ~UILDIN~ DEP~T~ENT. 5T2 oF ~ ~I~NT END~LL 5T~ oF 5 FRONT ~$~UCq*U~E ~NICM ARE NOT ~O ~ ~OOF LIve LOAD O~LLY INDICATED. 42 P~ ~OUND oN~ , L o~ 7F $TEEL AND ~S$OCIATED ~0~ IN ~LD~.COOE ~iND SPEED :5~. 5T5 of ~ T~IM DETAIL5 I P$F COLLATEraL , ~OES, FALSE~O~ O~ OTNE~ 5T~ or a ~ENE~L PET~ILS ,~ P~CTICE, 5'TM E~ITION.) 5T~ o¢ 5 TRIH DET~IL5 I S~EISMIC ZONE 5QU**E FEET IN *UILD]N* D NOT FO* CON$T*UCTJON ¢STEM UNLE55 APPrOvED IN ~ITIN~ OTNE~ E ~UILDIN~ DESIGN AND COULD ~ ~ APPrOVaL O~E~5 MUST  FO~ F~IG~TION ~ITHIN DAY5 AFTEf~ SUBMITTAL O~A~JING5 Af~JE 1551JEI~ Of~ Tt-4E OP--.DEf~ LUILL ESE 5UI~JECT TO ANY OUTWENT P~IOE ING~.EA$E. I PROPERTY OF: HERITAGE BUILDING 5¥STEMS INC(~ FOR QUESTIONS O~ AS$15TANCE COPYrigHT 2OO2 OONOE~NIN~ E~ECTION OF NE~ITA~E OONFIDENTI~L; TNI5 DOOB~ENT AND T~E BUILDINg5, GALL: INFOrMaTION CONTAINED ME~EIN P~OPE~TT ~ HERITAGE DUILDIN~ $T$TEM5 INC. UN~UTNO~IZE~ USES ~ P~OMI~ITE~. J.~.P. 4/IO/'~2 NORTH LITTLE ~OOK, GREENPO T, NY 11 44 SCALE ~UIL~INO: ~.,o. 5~EET NO. E UILE:)E S ES ON$1: GENE ,A,L NOT THE ~UILDER MUST SECURE ALL RE,MIRED APPROVALS AppF~OPRIATE A~ENCY AS REQUIRED. ApprOVAL OF HERITAGE BUILDING SYSTEMS DRAUJINGS TMAT NE~ITA~E NA$ CO~CTLT INTErPrETED CONTraCT D~IN~ AND SPeCIFICaTIONS. p~ACTICE, STW EDITION.) ~HE~ DI$C~EPANCIE5 EXI$T ~ET~EEN THE ME~ITA'. PLAN5 FO~ OTHER T~ES, THE STrUCTUraL 5TEE~ AISC .CODE ~ 5TAN~A~ PRACTICE, 5TN EDITION.~ DESIGN CONSIDERATON5 ¢ AN~ MATE~I~L5 IN TNF, FUll,NED ~% NE~ITA~E ~E THE ~ESPONSI~LIT%', THAN HERITAGE ENgINEErING UNLE55 5PEOI~ OTHE~ THE ~ILDE~ 15 ~ESPOHSI~LE FO~ ~LL E~ECTION ELEMENT5 ~QUI~D FO~ E~ECTION ~ILL ~ TME ~UILDE~, (SECT 1.~.1 AISC GO~E ~ 5T~NDA~ IT I~ %ME ~UILDE~5 ~ESPONSI~ILITT TO ~pPLT AND TNB ~UILDE~ I$ ~$PON$1~LE FO~ TNB verIFICATION AND ~T iNVENTOr% B~ILDIN~ ~T TI~E ¢ ~ELIYEf NO cMANGE$ $HOULD ~E MADE TO THIS ~UILDIN~ ~Y TNB MANUFACTUre5 EN~INEE~IN~ DEPA~TMEN'r'. UNAPIPROVED CHANGES COULD RESULT IN AN PUBLIC SAFETY. 11 o o L /4" I 3'/4" 3/4I' DETAIL ELU _3/4" 1}/4" See Plan DETAIL 1 1/2" }14" L31a = 5/4" 8 1/2 E)ia= }/4" ':1 EL~J/ SLU NOTES FOR ~E,AOTIONS +.he fo II~uita~ Ears ~ei~ht dft) ~oof S/op~ (rise/12 Collateral Load Luind Speed (mph Exposure Closed/Open importance - S~Tsmic AI'NONO~ E~OLT SUhflI"'1AF~'C To+,a IESencJ Loc Dia L~n Lan din) (in) (in) QFI',IF~,A,L NOTES 1. BOLT DETAILS SNOLUN ON TMI$ DRALUINQ LOCATE TNE ANCNOR BOLTS IN t~EFERENCETO ~OTN TIdE E~UILDING STEEL LINE' AND TNE OUTSIDE OF N~ITAGE'S SUGGESTED ~NEL RECESS OF 1-1/2"? FO~ TNE DE~IQN O~ TNE ANCNO~ ~OLT TO PE~IT TNE T~ANBFE~ OF TNE ~SE PLATE ~N~ TNE AN~NO~ ~OLT T~ANSFE~ OF ANC~O~ DOLTS IN RELATION TO CONCRETE. UNLESS OTNE~WJSE P~OVIDE~ [IN TNE DOCU~ENT~, NE~ITAGE BUILDIN~ S~TE~S FOR TME DESIGN, ~TERI~L ~N~ CONSTRUCTION OF TNE FON~TION E~E~ENTS. TNE USE O~$TO~ER S~Q~L~ ~$$U~E ~I~$ELF T~T ~DEQU~TE P~OVIS[ON$ ~E ~OE IN THE FOUNdaTION ~ESIQN FO~ LO~S I~POSE~ GOLdeN ~EAOTIONS OF T~E ~DIL~INQ, OTNER ]~POSED LO~D$, ~ND BEA~ING CAPACITY OF T~E SOILAND OT~ER QONDiTIONS OF T~E ~UILDING I$ ~ECO~EN~E~ TN~T TNE ~NO~O~QE ~N~ FOUNdaTION OF ~UiL~INQ ~E ~ESI~NE~ ~Y ~ PROFESSIONAL ENGINEER EXPERIENCED TNE DESIGN OF SUCN STRUCTURES, (SECTION ~1~ M~M~ 1~86 LOW ~ISE ~UIL~ING 5. DOTTO~ OF ~LL ~ASE PLATE5 ARE AT ~E,A, OT/OI'qS (k DL * CL + * GL * LL D.4 13.q DL + UJL LUL 5.2 EI",!DLU,A, LL COLUMN, ~EACTIONS("kt hlAX/~Uml MAXIiMLIIM VERTICAL DL+GO+LL=6.2 VERTICAL DL*WL = :3.¢ NO~IZONTAL DL+LUL = 2.3 ~SF~,A,C. ING F~E,A, OT[OI-,,IS, p,A, IxlEL__ SNEA~ ---LUa/I--Col --Wind .... Sefsmfo- Shear Loc Id Ic~ Norz L__EW I 4 ? ~ ELU 5 4,? E>EE$C~IF'ION: ANCt40~: SCALE N~XI~II¢ SEE covE~AP~2 oF p-2 (T~p) E-2 P-2 (T~p) p-I (T~p) E-2 t~OOF 5NEETIN~ t~/~11~ t=t~AhlE ELEVATION ISSUE t~EV. IDESO'I~IPTION PATE ~1 =1= /~(,'~ E;,ESC~IPTION: I~IGIE~ F~AME ELEVATION ~ P.o. ~ox 4]e ~E~ITAGE JO~ * NYXI~II~ ~ NO.TV LITTLE ~OC~, A~ 1211D ~A~LN~ ~T DATE ONEC~ ~Y JAP 411¢1¢2 -SCALE SSUE ~ 4 EC-I OUT-TO-OUT OF STEEL 9'-® 114" G-I ~'-® I/4-" £ ~'~-2 PM] FF~APIE L/NE E EC-2 E EC-I II If 3/4" OUT-TO-OUT OF STEEL PMI c3'-® I/4" EC-i f=hll EC-2 ENDLJALL (~)N FF~,.-4MING: FF~,&hIE LINE 314'1 Ec-2 ER-I EF~-2 PA~T 8X35012 8X55Cl2 8X25ZI2 LENc3-FM I.~' 4 5/8" ]4' I~ 5/8" 2©'-.~ 1/16" 2©'-3, I/IG' ~'-4 CCh[NEC ] ICl I FRAI'IE d 5 TRI1"fl TABLE FRAh'IE L rNE 4~ 5 ©ll~ ~A Rt<. LENGTN E)ETAIL I ~T3 16'-2" T~Ir-I 4 P~2 PE~2 F F ENDLU,~LL SNEETII'qG ,~ LINE EIxlDLLIALL 5NEETING 4 PANELS: 2~ Ga. PF.~ - ~:ern Gr~n F~,h'IE LINE 5 / ~UIILDING CLJSTOI"IEF-~: P.J. CO*~IZINI / S'FSTEhIS LOCATION: ~.~EENPORT, NY / HERITAGE JOE~ * N'FXF311® 8®'-¢" OUT-TO-OUT OF STEEL E-I DN-I E-2 Q-4 E-2 [ I ] 12'-®" ~,. p -®= =Tn= = 12'-®" LINE 80'-®" OUT-TO-OUT OF eTEEL E-4 (.) () Ec-I ¢:=c-I ~Fl-I ieF]-I ieFJ-I I'-I D/4" I'-I 514" P-I 314" %1 ;/4" I,'-I ~/4" %1 ~/4" SIE>ELUALL F~.,AMING: LINE () MEME~EF~ T~ISLE FF.%~ME INE A 4 ED MAF~ f~AF~T E)P!-I ]3'-4" ]~'-4" 12'-©" I'~' :1/ I/2 I%' /1 I/2 I%' I1 I/2 1%'-11 I/2 I%'-I1 I/2 IC3' ~ I1 I/2 2' 1'-4 I/2" ®' 4 I/2" 21'-1 I/2" 22' 3 I/2" TRIM TAE~LE FF~-AI'IE LINE A 4~ ED ©1 MAR~ LENGTH NG4 2®'-2" FL-832 14' FL-23E5 12'=2" F/-2~ 12 '-4" D E T xS I L T~IM 16 TFeI]'I b T~ll'fl OE~2 -L GE4-L " " " " " " " " " '- '- '- " GE4-ie GE4-L IZIZiZIZI IZIZI-~ I-Z' IZIZ ~1Z1-%1 / (Gutt~re ~uTth -~ ~o~unspouts) I GE4-~ SIDELLI,&LL SHEETING4 TRIM: FIeAME LINE PANEL~: 2~, Ga. F:'ie - F~rn Green F'ANEL~: 26 Ga. Pie - F~rn Gr~n NE~IT,&GE ESbI~LDING SYSTEMS P. O. ~OX 49~ NORTH LITTLE ROCK, AR I-SO¢-~43-DSDD DE$CF~IPTION: $1DELJALL FF~AhllI~3 LOG,eTLON, GteEENPOF~T, NY NEtelTAGE JOD ~ NYXI911® JAP 4/1¢/®2 O.i'1. E!.T,S., NYXI%II® SE~ COVE~ ST} oF ~ I c', 4~'-®Ir PC.- ~,AFRTITJON 1 FFR.,AI"IING: F ? F~.AFRTITJON 2 FF~hfl[N~: :1 N OONNEOTION ~ I_A¥~, F~AI'IE L, 11'4E: I ~l2 2 PARTITION E~AC.K. SHEETING 4 TP--..IIM PANELS: 2~ ~a. PR - Polar I~hlt~ f~Af~TIT[ON 2 E~AC.t<. SMEETING 4 Tf~IM PANELS: 2~ m~a. PR - Polar LUhit~ C ~ NE~ITAQE JO~ * NYXI~II¢ ~ NO,TN LITTLE ~OCK, AR ~211b JAP 4/1¢/¢2 O.~. ___~.1:' PG-2 F>~X~TITION 5 F~PIlNG: PC- I'IE1MBEt~ TABLE PAf~TJTION 3 I"I,~RKPART LENGTM PC-1 8X~bCI4 I~'-q 5/1~" PC-2 ¢X~SG14 15'-I 5/1~" ~-2 8X35014 4'-I 15/16" Q-~ 8X2~Z16 8'-8" CONNECTION PLATEE LINE: ) i q I ~- I I I ® I I I I i - _ ~ ~ I I I I I I I ~ I I I I I ® I I I I I I I I F~AI~TITION 5 ~AOK SHEEETINC~ ~; T~lhl 'PANEL$: 2~3 Ga. F~ - Polar LJhit~ 155W~ t~V. D~$Of~!IPTION NYXI~II® ~31 .~S1-EEL LINE .aSTEEL LINE RBDF ENDWALL COLUMN - · , FLgE]R~ .'i / - ~g12 S,D, SCREW · o / ~WELDED ~ END'ALL END,ALL ~ ~ ~ 5 II A3a5 SHUTS _ _ _ ~ / o o < < (~) ~/~"¢ X PLATE VEL~E~ Ii il S~EWALL G~RT 0 SLOPED C~NCRETE N~TCH TB CDLB F~RHE~ ~1 II I I~cDL? Z/8"~ x KEEP VATER ~UT DF ~U;LDZNG END,ALL, II F~RHE? ~307 ~BLTS % SC-5 ~LLP PLAN ~E PLATEELEVAT~BN PLAN ~ASE PLATE ELEVATION RAFTER ~ ~- RAFTER Z/~¢ x ? A307 B~LTS SECT;ON THRU OBL? F~R~E~ EN~WALL C~LUHN TB EN~VALL C~LU~N TB ~ALL 5LRT EBRNER COLUMN TB ~LL ~JRT ENDWALL DBBR JAH~ ENDWALL COLUMN AT BVERHEA~ ~BBR WALKDBBR EN~WaLL RAFTER COLD FBRHED RAFTER EaVE STRUT ~EaVE STRUT ~ ~ ~ ~WEL~E9 / , ~ELDED -- ~X~R /~ BRACE ~__ oU ' , X ENSWALL RAFTER ~ ' GIRT COLUMN / L- EAVE STRUT J I ~ ~ SECTION ELEVATION EE ENDWALL DRAWING CLIP WELDED SECTION ELEVAI']BI,i TD RF CBLUHN WALL GIRT~ (a) 1/a"~ x 1" ~307 ?BLTS FOR ?BLT DIA AND TYPE, (6) 1/a~ x 1" A307 9BLTS (6) 1/~"~ x 1" A307 9BLTS 1/a"~ x i 1/4" A307 9BLTS ~/~"~ x l~ ~307 BOLTS (TYP> SECTION ELEVATION 1/~"~ x 1~ ~30~ SDLTS (TYP) ~BBR HEABER TB RAFTER SPLICE RBBF PURLIN TS WALL GIRT TD EAVE STRUT TB EAVE STRUT TB WALL GIRT TB DBBR JaMS SBBR JAMB TB EAVE STRUT AT SURFACE CHANGE INTERIOR FRAHE RAFTER INTERIOR FRAME CBLUHIN COLD FORMED RAFTER RIGI~ FRAHE DBBR JABS SIDEWALL COLUMN ~ / -- ANCHOR ~ II CLO~U~ %TC~ CONCRETE BOLTS ~ / ~Y OTHERS, MUST BE ADEQUATE FOUNDATION CBNCFRETE PLAN ELEVATION SIDEWALL CDI_UMN AND CONCRETE FOUNDATION CONCRETE FOUNDATION VITH BASE GIR% ~NO~T ~AFTE~ ~ET~EEN PURLIN5 RA~GNE~TED~ETAIL~L~[TN JA~BF¢~ T~IM,,R,, pANmL~ET~IL EO~ "~" * "~" ~AN~ O0~ERFO~ "A"T~I~ANELDETAIL ~BLTE~ o ~ ~TOP ~OLTS, SEE TOP FLANGE~ o O ~--TBP BOLTS, SEE ~ ~OLT OL~P o o INTERMEDIATE BBLTS, PLATE-- o o INTERHEBIATE BOLTS, ~OLT TO THE NUHBER DF TOP THE NUMBER BE TOP U NOTE: HOLE& pUrLIN5 CDLIjPIN CONNECTION COLUMN CONNECTION NOT LOCATED AT RIGID FRAME -- O 0 O O UIL ING cusTo **' ..J. co**,ax SYSTEMS LOC*TION: GREENPORT, NI' NE~ITA~E Jo~ ~ NYXIDII~ P. O. ~OX 4]~ D~dlN~ ~T ~TE CHECK ~T oc-[ E LITTLE ROCK, AR ]2115 JAP 4/IO/O2 N T.S. EAWE DETAIL UglTN SIMPLE EAYE TRIM AND 51..AEETED U.JALL PANEL PANEL EAVE DETAIL WlT~ GUTTER AND 5;-IEETED LU,,6,LL EAVE TR[;/ RAKE TRIhl ~% 5TD, I~"A~O1 4 WASHER5 OUTSIDE FLANC~E CORNER BOX TIE-IN 12" 12" 12" ~ 12 II (~ 12 I' ~ 12 {I Ic~II~T LAP E~OLT5 NOT] FIN HEAD (No W. ASNER FIROT LAPPED GIRT ~CTOR NOTE: AT EACH LAPP~B, GIRT CONNECTION, (I) 1/2"× III FiN NEAP DOLT NW3~2 MUST ~E U~ED $O ~$TAC~ T~E FI~ST OIRT FO TNE 51RT CLIP ~ A LAPPED CONDITION. THE BOLT~T [ A55EIdBLY I'IUST ~E ~NOM TIGHT PRIOR TO THE SECOND L~PPEP ~IRT BEIN~ IN~q ALLEP. ~F~MCE THE 5TANDA~ "O~H,L LAPPED ~[RT PETAFL" FOR HO~ INFORMATION. ( ) 5HOP WELD ~COLUMN GIRT / GIRT LAP 3/4" SEE ELEVATION 5EE ELEVATION LAPPED GIRT5 ~ INTERIOR BAY GOLUIdN5 NOTE: USE (3) I/2"xl If2" A3¢1 BOLT5 REFERENCE ERECTOR NOTE FOR TYPICAL WASNER REQUIREMENT5 SECOND LAPlanD a]RT GiRT CLIP Pop Riw~,%.. NOTE: INSULATION MUST E~E IN$TALLED ,,6,5 SHOWN OR ~OOF WILL LEAK. PANEL UIALL Pop Rivet Down,pout 5traf BAll pani "A" PAWEL DALL DOILJN$i'~OUT $TRAP ATTACHi'IENT La Pop Rivet __ '[_= FTeld ~end Gutter ~J?z~// 'wIN~ DOUJiqSPOUT TO GLITTER DETAIL MEMBER $CREU LOCATION (ALL MEi~BER$ EXCEPT AS NOTED) Detail IIA 12" Ill 12II 'Ill 212H ~ll I'dEM6ER $CRELU LOCATION De*,ail (PEAK PURLIN, EAvE $TRUT, AND PANEL END LAPS) Double Bead Tape %rlln NOI~ ~CI~ELU PATT~=t~N$ 6NOLUN, SATISFY REQUlt~EMENT5 FO~ t~OOF. SECTION THRU PEAK PURLIN AND PANEL END LAP5 AND II,ii PANEL F OOF 5Tn. I/2" 12Ii 12" 12" I¢Ii h'IEMCER 5CRELU LOCATION Pet~il 'IAI' (ALL MEMBERS) StDtch 5crem~ At . ConUnuous I/2 Tape Mastic 2~0" on ~~ 'PB~" Panel Onl~ DETAfL HAll PANEL WALL Pomn~pout Pop Rivet- Strut / ~utter Fleld Cut Gutter LUILh X" Pattern SECTION llAl' LUall Pane] DOUJNSPOUT DETAIL AT $NEETED UJALL iD.5. STRAP QLIANTITT EAVE HEIC~HTQUANTIT'i I¢'-¢ 2 12l-$ 2 [4'-¢ 2 2¢'-¢ 2 I$*UE t~.~V. ED~eO~I~'rION ~,~,TE HE~ITAC~E D~*C~I~TIOX, T~l~ / BLJILDIN~ C~$TOMER: P.J. CO~IZINI JAP / NYXI~II¢ SEE COVER