Loading...
HomeMy WebLinkAbout34380-ZFORM NO. 4 TOW/~ OF SOL~fHOLD BUILDING DEP~T~NT Office of the Building Inspector Town Hall Southold, N.Yo CERTIFICATE OF OCCUPANCY No: Z-34167 Date: 01/15/10 THIS c~KTIFIES that the building ANTENNA & EQUIPMENT I~cation of P~x)~rty: 9245 ~IN RD (HOUSE NO.) (STREET) County Tax Map NO. 473889 Section 31 Block 3 Subdivision Filed Map No. __ Lot No. __ EAST MARION ( HD~4LET ) Lot 11.31 conforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 12, 2009 pursuant to which Building Per.it NO. 34380-Z dated JANUARY 12, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ANTENNA ON AN EXISTING TELECOS~g3NICATIONS TOWER (AND EQUIPMENT) AS APPLIED FOR PER ZBA ~5826, DATED 8/16/07. (NEW CINGULAR WIRELESS) The certificate is issued to EAST MARION FIRE DISTRICT (OWNER) of the aforesaid building. SUFI~OI~ t~)[~Y DEPART}~qT OF H~%L~{ A~PROVAL N/A RY.R~-r~ICAL C~KTIFICATE NO. 129892C 08/28/09 PL~MB~ CERTIFICATION DA'r~u3 N/A Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is , denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C; Fees · 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pm-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commemial $15.00 Date. Old or Pm-existing Building: New Construction: Location of Property: (check one) House No. Owner or Ownars of Property: Suffolk County Tax Map No 1000, Section Subdivision Street Hamlet Frr Block 0003 Lot ~)//a OS/ Filed Map. Lot: Applicant: Cl°.~ ¢ u.. ~OF ~fe [~ PermitNo. ,-~q3 ~'0 DateofPermit. //]Z/O(~ Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ ~'-"~) o Underwriters Approval: Final Certificate: ~ (check one) (.5 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPA~RTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34380 Z Date JANUARY 12, 2009 Permission is hereby granted to: NEW CINCULAR WIRELESS PCS, LLC 333 CROSSWAYS PARK DRIVE WOODBURY,NY 11797 for : INSTALL. OF ANTENNAS ON EXISTING POLE & INSTALL. OF EQUIPMENT AS APPLIED FOR PER ZBA & PLANNING BOAPdD APPR. REPLACES (BP# 33500) at premises located at County Tax Map No. 473889 Section 031 pursuant to application dated JANUARY Building Inspector to expire on JULY Fee $ 250.00 9245 MAIN RD EAST MARION Block 0003 Lot No. 011.031 12, 2009 and approved by the 12, 2010 . ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT {THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33500 Z Date OCTOBER 30, 2007 Permission is hereby granted to: NEW CINGULAR WIRELESS PCS, LLC 333 CROSSWAYS PARK DRIVE WOODBURY,NY 11797 for : INSTALLATION OF ANTENNAS ON EXISTING POLE AND INSTALLATION OF EQUIPMENT AS APPLIED FOR PER ZBA AND PLANNING BOARD APPROVALS. at premises located at 9245 MAIN RD EAST MARION County Tax Map No. 473889 Section 031 Block 0003 Lot No. 011.031 pursuant to application dated OCTOBER 19, 2007 and approved by the Building Inspector to expire on APRIL Fee $ 250.00 ORIGINAL Rev. /8/02 Electrical Inspection Certifici te Elec'gi~J Inq)ecSon ~ervt~e, lnG. 37S Duntorl A~nue g~'t Pat~c~ue, NewYork 11772 (~1) 2864M2 Issued To: Cingular V~1reless Street: 9245 Main Rd Village: East Madon Section: Block: Contractor:. Militia I=loctrl6-- Zip: 11939 Lot: Town $outhold .... I.:1C7# 6244E * [] Cemmembd [] NVDe~ U Pool ~ 'lltFIoor I-'T Indoor [] B,~mmnt [~HotTub [] Reeldenlial [] Der. Glmlge ~ W [] 2nd Floor [] O~dom' [] A~ition [] ~ Sw~e~ Reeepmo/M FJm~TM GR HNMrs A,'C ~ I 1 1 i ~h~' VYasher/,~ D~ym'/An~ Oven RlnEe/lm~ Fumioe Oil ~il ClrouMors Smoke Deleotor J~ll ~ Meter ~ Ph~e U~/OH J~¢u'~ Televls~n / ~/C~. /:)em]~Y: 73346 Other Equiprtmnt 13-2p 30 Circuit 2-1p 30 Circuit 2-2p 15 Circuit CODet~'ter Hugo S, Surdi President Th~ oe~lflcate mu~t not be altered in any n~rmer. Inapectam may be Identified by ,~eit c4~edeat Jak'. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] ROU~PLBG. [ [ ] FOUNDATION 2ND [ ] I~ULATION [ ] FRAMING / STRAPPING [~,/] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION I 1 .RE.E.STA~ C0~~ I I F,.E RF..STA.T PE.ETRAT.. REMARKS: DATE INSPECTOR ~n~D tNS?ECnON mn'ORT FO~A~ON (1ST) ..................................... FO~ATION (2~) ROUG~ ~G & PL~G ~S~ATION PER N. Y. STATE ENERGY CODE PLANNING BOARD MEMBERS MARTIN H. SIDOR Chair WILLIAM J. CREMERS KENNETH L. EDWARDS GEORGE D. SOLOMON JOSEPH L. TOWNSEND October 14, 2009 Net Corn Development Att: Charles Eisenberg 30 Central Drive Farmingdale, NY 11735 PLANNING BOARD OFFICE TOWN OF SOUTHOLD Re: Site plan for E. Marion FD Telecom - final inspection Located: 9245 Main Road, Mattituck SCTM# 1000-31-3-11.31 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor, Main Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax: ~1 765-3136 OCT 1 4 2009 BLDG. DEPT. TOWN OF SOUTHO[O Dear Mr; Eisenberg: As per your request, the Planning Staff conducted a site inspection of the above property on Thursday October 8, 2009 where the site work was determined to be in conformance with your approved site plan, Please note any future requested change to the site plan should include a copy of the approved stamped site plan noting the location of the requested change. If you have any questions regarding the above, contact me anytime. Thank you. Since, relay Senior Planner Cc; Planning Board Heather Lanza, Planning Director Michael Verity, Chief Building Inspector Jamie Richter, Town Engineer API~EALS BOARD MEMBERS~ James Dinizio, Jr.. Chairman Gerard P. Goehringer Ruth D. Oliva Michael A. Simon Leslie Kanes Weisman ht tp://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631} 765-1809 · Fax (631) 765-9064 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF AUGUST 16, 2007 Mailin~ Address: Southold Town Hall 53095 Main Road · P.O. Box 1179 Southold. NY I 1971-0959 Office Location: Town Annex/First Floor, North Fork Bank 54375 Main Road (at Youngs Avenue), Southold, NY 1197l ~. ~ I~ECEtV~-D t 12,,/o ZBA File No. 5826)- NEW ClNGULAR WIRELESS, PCS LLC Property Location:, East Marion Fire District, 9245 Main Road, East Madon CTM 31-3-11.31 containing 3.05 acres Zone District: R-40 Low-Density Residential SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. In addition, the Town Planning Board has issued a Negative Declaration with a Determination of Non-Significance dated September 11, 2006. PROPERTY FACTS/DESCRIPTION: The applicant's property contains 3.05 acres owned by the East Madon Fire Distdct and improved with two Fire House structures. The East Madon Fire District (EMFD), an established special district for emergency communications, has a building permit issued for the tower, inside of which this antenna facility will be co-locatad. The EMFD maintains at its fire station communication transmissions to and from this site, and the wireless communications tower was determined to be in a tocation that provides sufficient space and height to provide an installation of a 450 Hz antenna, north of the firehouse, and sufficient land area of three acres shown on the October 25, 2005 9urvey prepared by Peconic Surveyors, P.C. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application has been referred as required under the Suffolk: County Administrative Code Sections A 14-14 to 23. The Suffolk County Department of Planning reply dated January 22, 2007 states that the application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. FINDINGS OF FACT APPLICANT'S REQUEST: By application received May 15, 2007, a request was filed by New Cingular Wireless) PCS LLC, applicantJlessee, for a Special Exception under Section 280-69A, based on the Building Inspector's April 18, 2007 Notice of Disapproval, concerning the proposed co- location of a wireless communications antenna on an existing approved tower. Town of Southold Chapter 280, Article XVII Wireless Communications Facility reads: ) Page 2 - August lS, 2007 ZFJ, File No. 5826- New Cingular CTM No. 31-3-11.31 '= Any unstaffed facility for the transmission and/or reception of wireless telecommunications services or other radio transmission and/or receiving service or use usually consisting of a wireless communication facility array, connection cables, an equipment facility and a support structure to obtain the necessary elevation. The support structure is either a building, telecemmunication or radio antenna or tower or other approved structure. [Added 11-12-1997 by L.L. No. 26-1997: amended 2-2-1999 by L.L. No. 3-1999] CODE ARTICLE XVII: Section 280-67 (former #100-160) of the Zoning Code allows wireless COmmunications, and particularly telecommunication towers, to be reviewed and approved in keeping with the town's existing zoning and historic development patterns, including the size and spacing of structures and open spaces. Furthermore, the Standards herein reflect two preferences: that wireless communication facilities are preferred in industrial areas and that wireless communication facilities be located on existing buildings and towers rather than on newly constructed towers. Any wireless communication facility must take into account the aesthetic aspects of the town, including open vistas, scenic byways and historic districts. In addition, the following provisions have been applied: § 280-68 (former 6100-161). Scope. [Amended 12~-1998 by L.L. No. 25-1998] The regulations of this article shall govern and ~control the erection, enlargement, expansion, alteration, operation, maintenance, relocation and rer~oval of all wireless communication facilities. The regulations of this article relate to the location and design of these facilities and shall be in addition to the provisions of the Southold Building and Zoni,qg Codes and any other federal, state or local laws or Federal Communication Commission (FCC) regulations pertaining to such facilities. Nothing herein shall be construed to, apply to, prohibit, regulate or otherwise affect the erection, maintenance or utilization of antennas or support structures by those licensed by the Federal Communications Commission pursuant to Chapter 47 of the Code of Federal Regulations, Part 97, to operate amateur radio stations. §280-69 (former #100-162). Location of use. No wireless communication facility shall be used, erected or altered in the Town of Southold when located in an R-80 Residential Zone District, except by (Planning Boa~) site plan approval, meeting the following requirements. (1) Wireless communication facilities on buildings shall require a special exception approval pursuant to:this article. Wireless communication facilities on buildings shall be no higher than 10 feet aboVe the average height of buildings (excluding signs, fences and walls) within 300 feet of the proposed facility. The building on which the wireless communication facility is located mus~ be located at least 100 feet from the nearest property line and 300 feet from any landmark property or district listed by federal, state or town agencies. (2) Wireless communication facilities on existing telecommunications towers shall require a special exCePtion approval pursuant to this chapter unless otherwise allowed by the terms of a prior special,exception approval (3) Wireless communication facilities on telecommunication towers shall require special exception approval pursuant to this article and shall not project higher than 10 feet above the average height of buildings (excluding signs, fences and walls) within 300 feet of the facility or, if there are no buildings within 300 feet, these facilities shall not project higher than 10 feet above the average tree canopy height in that radius measured from ground level. If there are Page 3- Augus116, 2007 Z~ File No. 5826 - New Cingular CTM No. 31-3-11.31 no buildings within 300 feet of the proposed facility site, all telecommunication towers shall be surrounded~by dense tree growth to screen views of the facility in all directions. The base of the lower shall be located at least 100 feet from the nearest property line and 300 feet from a landmark prOperty or district listed by federal, state or town agencies. (4) A wireiess communication facility is a permitted use, not requiring site plan approval, if located on property owned, leased or otherwise controlled by state, federal or town governmen! provided that a license or lease authorizing such facility has been approved by that govern~nent. The height of such facility may be established by the public agency. (5) A wireless communication facility is a permitted use, not requiring site plan approval, if located on property owned, leased or otherwise controlled by a special district, provided that a license or lease authorizing such facility has been approved by the commissioners of the special district, and provided that it does not exceed the maximum heights specified above. Section 280-70B(!-5). Code Standards. In addition to the standards in Article XVII of this Code, the Zoning Board of A~peals shall find and determine the following: (1) The applicant is a public utility. (2) The co-10cation of a public utility antenna is a public necessity, in that it is required to meet current or expected demands of the telecommunications provider and to render adequate service to the public. (3) The applicant has made substantial effort to co-locate on a permitted tower. (4) The fadlity conforms with applicable FCC regulations. (5) There are compelling reasons, economic or otherwise, which make it more feasible to construct the proposed antenna than alternatives. OTHER CODE CONSIDERATIONS: In addition to considerations under Article XVII (Special Exceptions) of Chapter 280, the Zoning Board of Appeals has given consideration to the following in issuing a special etxception approval for a wireless communication facility: (1) The antenna will be located within the tower without affecting the height, and Is the minimum necessary to render adequate service. (2) The antenna f(~r the wireless communication facility is to be situated within an existing previously approved monopole antenna and therefore will have no visual affects to residential structures, residential district boundaries and landmarks designated by town, federal or state agencies. (3) The antenna ,is designed and situated to be compatible with the nature of uses on adjacent and nearby property. (4) The antenna has been designed to minimize any possible visual impact. Page 4 -August 16, ~907 ZE[ File NO. 5826 - New Cingular CTM No. 31-3-11.31 RESOLUTION OF THE BOARD The Zoning Board of Appeals held a public hearing on this application on June 28, 2007 and August 2, 2007, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: 1 ) That the applicant is a public utility. 2) The applicant is locating (co-locating) within an existing approved monopole tower which is encouraged by th~ town to help mitigate the aesthetic aspects including vistas, scenic byways and historic districts. 3) The proposed antenna is compatible with the nature of uses on adjacent and nearby property, to the extent that East Marion has a commercial/industrial area, and within this area is a fire house, permitted tower for telecommunications, and New York State Highway Route 25. 4) There are compelling reasons, economic or othem/ise, which make it more feasible to construct the proposed antenna than alternatives. A) The location of the previously approved tower is at the East Madon Fire House which is in the heal1 of the business district for this hamlet. B) Other locations within the effective range of this tower, such as inside church steeples, are not high enough and would increase the need for additional towers and antennas by decreasing the propagation footprint required to sen/ica the areas. 5) The height;,at which the antenna will be installed, on the previously approved tower, will maximize the prol~agation footprint. The board has investigated other alternative sites within the effective range of the proposed antenna, such as church steeples and determines that (any) alternate site if ch0~en would increase the need to build more towers and antennas in the area, 6) The TelecOmmunications Act of 1996 addresses and regulates the strength of the signal emitted from telecOmmunications antennas for the purposes of health and safety, 7) The effect on real estate values will be minimal because the antenna will not be visible after it is installed on the inside of the previously approved tower. RESOLUTION OFTHE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Oliva, seconded by Member Page 5- August 16, 2007 Z~, File No. 5826 - New Cingular CTM No. 31-3-11.31 Goehringer, and duly carried, to GRANT, the special exception as applied for, as shown on Diagrams Z-01,. Z-02, Z-03, T-01 prepared 4-16-07 by Inflnigy Engineering, date stamped May 4, 2007 by the Zoning Board of Appeals. Vote of the Board: Ayes: Members Dinizio (Chairman), Oliva, Goehringer, and Weisman. Simon was absent. This Resolution was duly adopted (4-0). Ja~n~s Dinizio Jr., ZBA C~airn~an A~proved for Filing ~' 8/2~/2007 Member S 65'40'00" 19.38' I STORY FR. FIREHOUSE FOR INTERNAL USE SITE PLAN USE 2O07 Initial Determination Date: ~ / I~t' / Project Name:~ Project Address:~ ?_z(- ~ Suffolk County Tax Map ND.:1000, Request: (Note: Copy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) Initial Dete,,rmination as to whether use is permitted: (p~¢* /,~¢_/"¢zA,4 / ~-7-~)~"~ Initial Determination as to whether site plan is required: %-*/~-~"- ,~L, Ct-- ~ Signature of Bh21¢dlng~r Planning Department (P.D.) Referral: P.D. Date Received: ~ / ~ /Ode Date of Comment: ~ / ~ ~' / O-/~- ,Final Determination Date: ~/,~ / 87 S~~eviewer Signature of BuildiYig Ins~ecffor FOR INTERNAL USE ONLy SITE PLAN USE DETERMINATION Initial Determination Date: ~/ / Project Name:~ Project Address:°(?..zlL ~'~ ' ,<~-o,-~ DateSent: 'i~ I I'~ Suffolk County Tax Map No.:1000, "~ I - 3 -//'~ / Zoning District: Request: (~o-~ ~ C/¥'F'~'. ~.~,~,,~,/,./~ ~ ~3~j ..~.~. / % (Note: Copy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) Initial Dete. Lrmination as to whether use is permitted: Initial Determination as to whether site plan is required: ~-~/ Signature of B~llding~r Planning Department (P.D.) Referral: P.D. Date Received: / / Date of Comment: Comments: Final Determination Date: / / Decision: Signature of Planning Dept. Staff Reviewer Signature of Buildi~'~ Inspector COMPLETE w'rRELE$$ CONTRAC'I" N6, NC. July 2, 2007 · . ./. ¢ :-~., 'h' ~ Re: East Mar~on Fire Dts~t~c~¢ ~-~ ,~ MainRd.,E.M~oa, N~ ~/ II ~ '~ - . . ' t~,7 To Whom it may concern: The ceded cost of con~ucfion for ~e ~ta~ation of C~gnlar's eq~pment at the above mentioned site i~ $70,000.00. Ve~ tr~ ~o~, President 99 West Main Street, E. Zslip, NY 11730 631-§81-8105 phone 631-581-820§ fax I~LANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND September 11, 2007 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cot. Main Rd. & Youngs Ave.) Southald, NY Telephone: 631 765-1938 Fax: 631 765-3136 Edward J. Boyd, Esq. 54655 Main Road P.O, Box 1468 Southold, NY 11971 Re: Proposed Site Plan for East Marion Fire Department Telecom Located on the n/s/o NYS Route 25, approximately 494' w/o Stars Road, known as 9245 State Route 25, East Marion SCTM#1000-31-3-11.31 Dear Mr. Boyd: The Southold Town Planning Board, at a meeting held on Monday, September 10, 2007, adopted the following resolutions: The final public hearing was closed. WHEREAS, this site plan is for the co-location of Cingular at 107' height, on an approved neutral blue/gray 110' communications unipole tower with fire/police emergency communication mounted on a cross bar at 30' and includes a 16' x 22' enclosure with a 6' high fence on a 3.0583-acre split-zoned parcel in tile R-40 & HB Zones located on the n/s/o NYS Route 25, approximately 494' w/o Stars Road, in East Marion. SCTM#1000-31-3-11.31; and WHEREAS, East Marion Fire District is the owner of the property located on the n/s/o NYS Route 25, approximately 494' w/o Stars Road, in East Marion; and WHEREAS, on December 9, 2005, the agent, Lawrence C. R6, working for New Cingular Wireless PCS, LLC, submitted a formal site plan for approval; and WHEREAS, on January 6, 2006, the New York State Department of Transportation responded after review and determined a permit would not be necessary as long as all work is out of the State ROW; and WHEREAS, on January 6, 2006, the East Marion Fire District responded that current fire access is sufficient for the proposed plan and that "the landscaping be up-graded to fully screen all fencing, including barbed wire in addition to other ground equipment and structures"; and WHEREAS, on January 11, 2006, the Suffolk County Department of Planning responded after review and determined this matter is for "local determination as there appears to be no significant county-wide or inter-community impact(s)" and the Planning Board accepts this pursuant to 239L & M General Municipal Law; and East Marion FD Telecom Paqe Two September 11, 2007 WHEREAS, on March 1, 2006, the Architectural Review Committee reviewed the architectural drawings aind associated site plan materials and recommended "a re-consideration of height and location to reflect impact on existing and future nearby residential properties"; and WHEREAS, on May 4, 2006, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and suggested street trees be added to the east side of the property along NYS Route 25 and the Planning Board forwarded this recommendation to the Southold Town Tree Committee for comment; and WHEREAS, on July 24, 2006, a new agent, Edward J. Boyd, Esq., working for East Marion Fire District, submitted a revised site plan and application for approval; and WHEREAS, on September 12, 20,06, the Southold Town Planning Board acting under the State Environmental Quality Review Act, pursuant to 6 NYCRR Part 617.7, performed a coordinated review of this Unlisted Action. The Planning Board established itself as lead agency, and as lead agency, made a determination of non-significance and granted a Negative Declaration; and WHEREAS, on December 14, 2006, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and approved the tower's change in color to light blue; and WHEREAS, on March 8, 2007, the Southoid Town Zoning Board of Appeals, under Appeal Number 5972, denied the variance as applied for and granted "a variance in the location shown on the 6-17-06 Infinigy Site Diagram (setbacks 105 feet from the north lot line, 196 + feet set back from the westerly lot line), at a maximum antenna height of 110 feet, subject to the following conditions: 1. The covering of the monopole shall be painted a color that will make it blend into the area. The board suggests a neutral color such as gray or gray-blue. 2. No flag shall be placed upon the monopole antenna. 3. The monopole shall not be lighted except as required by law"; and WHEREAS, on April 19, 2007, the Southold Town Building Department issued a Building Permit for the "construction of an emergency communications tower per ZBA #5972 as applied for" under Building Permit #32920Z; and WHEREAS, on August 16, 2007, tl~e Southold Town Zoning Board of Appeals granted a Special Exception described under Appeal Number 5826 for the proposed co-location of a wireless communications antenna on an exiisting approved tower; and WHEREAS, on August 22, 2007, the Southold Town Engineer responded, after review, with three (3) comments and the Planning Board accepted the following comments with the exception of comment #3: 1. The proposed new "Unipole" Telecom Tower and Equipment Compound is to be constructed on the north side of the existing Fire Department facilities in the open lawn area. The proposed area of new impervious surfaces for this project will not generate a significant amount of stormwater run-off. Therefore, it is recommended that the proposed landscaped areas be constructed within a slight depression to contain and recharge run-off that will be generated by the development of this site. East Marion FD Telecom Pa.qe Three September 11, 2007 It is not clear if there are any additional roadways or pavement surfaces proposed for access to this equipment compound? If there are, drainage calculations may be required. If no additional site improvements are proposed, additional drainage structures will not be required. The proposed setback from the northerly residential property line for the installation of the Cingular Unipole has been indicated as +/- 105'. This setback is in excess of Town Code Requirements, 100' under Section 280-69 (3), but this unipole is detailed at a height of 110'. It is recommended that this setback be a minimum of 110'; and WHEREAS, on September 6, 2007, the Southold Town Building Inspector reviewed and responded "The proposed use Wireless Communication Facility on an existing telecommunication tower is a permitted use by Special Exception in this R-40 District and is so certified" with a reference to the ZBA Appeal #5826; and WHEREAS, on September 6, 2007, the East Marion Fire District submitted a letter stating, "The Board of Fire Commissioners of the East Marion Fire District requests that evergreen screening be placed on alt four sides of the equipment compound at the base of our tower. In addition, the Board of Fire Commissioners reserves the right to grant final approval for all plantings" and the Planning Board accepts these comments for the file and is not requiring additional landscape at this time; and WHEREAS, on September 7, 2007, the Southold Town Tree Committee responded, after review, stating: "It is our conclusion there is no need for additional trees on or near the road front of this property" and the Planning Board accepts this recommendation; and WHEREAS, the Southold Town Pllanning Board, pursuant to Chapter 58, Notice of Public Hearing, has received affidavits that the applicant has complied with the notification provisions; and WHEREAS, the following items shall be required: All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. The lighting must meet Town Code requirements. 2. As per the landscape survivability guarantee, the applicant agrees to replace any of the landscaping which dies within three (3) years of planting; be it therefore RESOLVED, that the Southold Town Planning Board has reviewed the proposed action under the policies of the Town of Southold Local Waterfront Revitalization Program and has determined, in a memo dated April 26, 2006 prepared by the LWRP Coordinator, that the action is consistent provided that the Best Management Practices outlined are implemented including: 1. Require the use of native plants and encourage the use of disease-resistant and drought-tolerant plants in landscaping. 2. Require a Maintenance Plan and two year survival requirement for all planted vegetation. East Marion FD Telecom ,PaRe Four September 11, 2007 Recommend the use of mulch materials generated by the Town of Southold Compost Facility which contribute to the replenishment of organic matter in local soils and help reduce the reliance of fertilizers and herbicides and minimize the reduction of fertilizers and herbicides in the Town's ground and surface waters; and be it further RESOLVED, that the Southold Town Planning Board acting under the State Environmental Quality Review Act, pursuant to 6 NYCRR Part 617.7, issues a revised Negative Declaration for this Unlisted Action to reflect the current proposed build out of the site; and be it fudher RESOLVED, that Local Law 16 entitled "Temporary Moratorium on the Processing, Review of, and making Decisions on application for Building Permits, Site Plans and Special Exception Use Permits for Wireless Communication Facilities in the Town of Southold", does not apply as per the exclusion which states, "Applications for co-location of wireless telecommunications facilities inside a permitted tower, with no component pads visible from the exterior"; and be it further RESOLVED, that pursuant to Southold Town Code 280-131 Part I, the applicant agrees to incorporate all the requirements, comments, and recommendations of each reviewing agency as referenced above and as indicated on the site plan and corresponding attachments; and be it further RESOLVED, that the Southold Town Planning Board grant approval on the site plan packet, T01 and Z01-Z05 prepared by Infinigy Engineering and certified by John S. Stevens, P.E., dated June 20, 2006 and last revised April 16, 2007, and authorize the Chairperson to endorse the site plans with the following conditions: The owner, agent and/or applicant agrees to submit, in writing, any proposed changes in landscaping from the approved site plan to the Planning Board for review. The Planning Board reserves the right to request a revised site plan detailing any changes in landscaping if necessary. 2. The site plan approval requires that all work proposed on the site plan shall be completed within three (3) years from the date of this resolution. Prior to the request for the Certificate of Occupancy, the owner or authorized agent must request, in writing, the said Building Inspector and the Planning Board to perform an on- site inspection to find the site improvements are in conformity with the approved site plan. Prior to the request for an on~site inspection, the applicant/agent/owner must submit a copy of all required approvals from any necessary agencies to the Southold Town Planning Department. 5. If the as-built site improvements vary from the approved site plan, the Planning Board reserves the right to request a certified as-built site plan detailing all the changes. Any changes from the approved site plan shall require Planning Board approval, and any such changes without Planning Board approval will be subject to referral to the Town Attorney's Office for possible legal action. The Planning Board will issue a final site plan approval in the form of a letter following a site inspection and at the time the site improvements are found to be in conformance with the approved site plan. East Marion FD Telecom Pa.qe Five September 11, 2007 A copy of the approved site plan is enclosed for your records. As per the Town Code, one copy each will be distributed to the Building Department, Zoning Board of Appeals and Town EngineedHighway Department. In addition a copy of the revised Negative Declaration is enclosed for your records. If you have any questions regarding the above, please contact this office. Very truly yours, Chairperson enc. cc; Southold Town Zoning Board of Appeals (with map) Southold Town Building Department (with map) Southold Town Engineer ('with map) Munley, Meade, Nielsen & R~ (with map) Suffolk County Planning Department File ~LANNING BOARD MEMBERS ~ JERILYN B. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND PLANNING BOARD OFFICE TOWN OF SOUTHOLD MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cot. Main Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 State Environmental Quality Review NEGATIVE DECLARATION Notice of Determination Non-Significance September 10, 2007 This amends the previously issured Negative Declaration dated September 11, 2006 to revise the project description as per the Southold Town Zoning,Board of Appeals decisions, #5972 and #5826. This notice is issued pursuant to Part 617 of the implementing regulations pertaining to Article 8 (State Environmental Quality Review Act) of the Environmental Law. The Southoid Town Planning Board, as lead agency, has determined that the proposed action described below will not have a significant effect on the environment and a Draft Environmental Impact Statement will not be prepared. Name of Action: Proposed Site Plan for the East Marion FD Telecom SCTM#: 1000-31-3-11.31 Location: On the n/s/o NYS Route 25 approximately 494' w/o Stars Road known as 9245 State Route 25, East Marion SEQR Status: Type I ( ) Unlisted (X) Conditioned Negative Declaration: Yes ( ) No (X) Description of Action: This site plan is for the co-location of Cingular at 107' height, on an approved neutral blue/gray 110' communications unipole tower with fire/police emergency communication mounted on a cross bar at 30' and includes a 16' x 22' enclosure with a 6' high fence on a 3.0583-acra split-zoned parcel in the R-40 & HB Zones located on the n/s/o NYS Route 25, approximately 494' w/o Stars Road, in East Marion. SCTM#1000-31-3-11.31 Reasons Supporting This Determination: An Environmental Assessment Form has been submitted and reviewed and it was determined that no significant adverse effects to the environment were likely to occur should the project be implemented as planned. SEQR Neqative Declaration page Two September 10, 2007 No major change in the use of either the quantity or type of energy will occur. No known creation of a hazard to human health is expected to occur. The proposed action will not cause a substantial change in the use, or intensity of use, of land including agricultural, open space or recreational resources, or in its capacity to support existing uses. No substantial adverse change in existing air quality, ground or surface water quality or quantity, traffic or noise levels, no substantial increase in solid waste production, potential of erosion, flooding, leaching or drainage problems will occur as a result of this action. The property is zoned Hamlet Business (HB) and R-40 (Residential) and does not contain significant vegetation. No significant removal or destruction of large quantities of vegetation or fauna, no substantial interference with the movement of any resident or migratory fish or wildlife species, no significant impacts on a significant habitat area, no substantial adverse impacts on a threatened or endangered species of animal or plant or the habitat of such a species, and no other significant adverse impacts to natural resources will occur. The proposed action will not impair the character or quality of impodant historical, archaeological, architectural, or aesthetic resources or of existing community or neighborhood character. The proposed action is not in material conflict with a community's current plans or goals as officially approved or adopted. On August 24, 2006, the Suffolk County Department of Planning responded that as an interested agency they "have no objection to the Town of Southold assuming Lead Agency". Based upon such, no significant adverse impacts to the environment are expected to occur should the project be implementedl as planned. There has not been any correspondence received from the Southold Town Zoning Board of Appeals, Southold Town Building Department, Southold Town Board, Southold Town Engineer or New York State Department of Transportation in the allotted time. Therefore, it is assumed that there are no comments or objections from these agencies. For Further Information: Contact Person: Address: Telephone Number: Amy Thiel, Senior Planner Southold Town Planning Board 631.765.1938 Cc: Southold Town Zoning Board of Appeals Southold Town Building Department Southold Town Engineer Suffolk County Planning Department File NEW cingular WIRELESS SITE NUMBER: L1-1017 CINGULAR ID: NYCENY1017 SITE NAME: EAST MARION DRAWING INDEX T01 Z01 Z02 Z03 Z04 Z05 TITLE SHEET SITE PLAN DETAILED SITE PLAN AND DETAILS ELEVATION VIEWS CONSTRUCTION DETAILS LANDSCAPE PLAN 11~ UNDI~ONt~. PURSUANT TO $OUTROLD TOWN CODE SECTION ,,~'~,-., ~--~,~,~ ' ~... ,~.,:~c ~o~ p~ ~ NO~: ~e ~rov~ site develo~ pi~ ~.~ a ~od of~ (3) ~ ~m ~ ~ of~v~ ~ ~ code sec~ ~00-255, - - REV 0 0 0 0 0 0 DIRECTIONS VICINITY MAP PROJECT INFORMATION LATI~JDE (NAD 83): LONGITUDE (NAD 85): ELEVATION (NAVD 88): AN UNMANNED TEL/COMMUNICATION FACIUTY INCLUDING 1~HE INSTALLATION OF OUTDOOR EOUIRMENT CARINETS AND (5) PANEl_ ANTENNAS MOUNTED WITHIN UNIPOLE. SITE QUALIFICATION PARTICIPANTS NAME COMPANY NUMBER A/E JOHN STEVENS INFINIGY ENGINEERING (518) 434-2288 SAC JOY MOONEY HIGHLANDER CONSULTANTS, INC. (631) 581-8105 LANDLORD DANIEL WOOD EAST MARION FIRE DISTRICT (651) 477-05.39 CON GERRY BROCK BECHTEL (205) 555-5505 RF TARIK OUAZZANI BECHTEL (201) 755-2154 50-034 EAST MARION . ..~iTE~NO. L1-1017 9245 MAIN ROAD ingular ::= =:=-_ ==: WIRELESS o o*~ RE~S.~S ~ C.K .'~ TITLE SHEET 24897 NYCENY1017 TO1 ANTHONY LEKAKIS \ 1. SITE PLAN INFORMATION WAS WAS BASED ON VARIOUS SOURCES , USE: RESIDENTIAL VACNAT LAND ~\ \. ~ OF INFORMATION INCLUDING FIELD NOTES & MEASUREMENTS / ZONED: R-40 ~9~/''~ ~ '\\ ~ACT~ALS~TE pLANF1ELDIS NOTcoNDiT1oNTO SCALE.oF ~ PERFORMED BY INFINIGY ENGINEERING. PLLC OF NY. " .~' ~ ~ ~ ~ X ~ I EXISTING BUILDING STRUCTURE IS 2. THIS PROPOSAL IS FOR AN UNMANNED TELECOMMUNICATIONS FACILrPf N/F ~ ,¢ ./' / c~\ ~ \ \ '~ NOT WHAT IS DEPICTED ON THIS CONSISTING Of PANEL ANTENNAS MOUNTED TO A UNIPOLE, USE: RESIDENTIAL- I FAMILY RESIDENCE, ~,\\\ ~TOWER SETBACK D,MENSIONS ARE LEASEHOLD, AND ASSOCIATED APPURTENANCES. - LOT, ~VA~.\~../~,~?~?-,,,~ . \~\\'~ ~ ~. THEPROPOSEDC'NGU~WIR=SSSE~OEE^O,U~ISUNMANNED. AND IS ,OT,~NBED FOB ~- ~---~ FENCED LEASE ~REA , ,~-'~ , USE: 1 FAMILY \ ~ S. OCCUPANCY IS UMITED TO PERIODIC MNNTENANCE AND INSPECTION ~'.~, ~.-~~~_;$B' · USRE~.s~DEFi~USE: 1 FAMILY ~,.~.'~,, ~ ~ \\ ~ 7. THIsNO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM _\--~.~ ',,.-\~ B. OUTDOOR ~O~GE AND SOlD W~ C ONT~NERB ~E NOT PROPOSED. KORTSOLAKIS ~ ARKING ~REA \ 11. TOTAL ARea OF DISTURBANCE UNDER THIS PROPOSAI~ 570 SF:~ ZONED: R-40 12. THE INCREASE IN STORM WATER RUNOFF DUE TO THE INCREASE IN / \% . \ \ \ NOT BE RED. THEREFORE, E UOTHRESANENOT ROPOSED. ~'%'~*~' \, SPECIFICATIONS. STANDARDS. AND REQUIREMENTS OF THE GOVERNMENTAL ~'~ '~' O~ / OR UTILITY AUTHORITIES HAVING JURISDICTION. , ./.~ ~ 14. ALL EXISTING ACTIVE SEWER, WATER. GAS, ELEC~IC. AND OTHER UTiLITiES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED // AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXEcLmoN OF ~~E ~- ~ .~.,~/~kco.-/ THE WORK, SHALL BE RELOCATED ~S DIRECI[D BY ENGINEERS. USE: 1 FAMILY RESIDENCE ~' ,-~-~ /~/ "-;"-;/ NOTE: METES AND BOUNDS ARe TAKEN EXTREME cALmON SHOULD BE USED BY 3HE CONTRACTOR WHEN ~~.~ ~ ~^ B~ ~er~oRMeD BY EXCAVATING OR PIER BRI~RO AROUND OR N~ ........... \~ ~ ~/ ~/.~.~/~'/ PECO.~ su~o~ ~. uc~sED co~mOR S~ PRO. DE ~ ~.~RO FOR THE WORK,RD N/F ~ ~/ ..~ZE?STiNG 16. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER E.M. wAN M~OR~ ASSOC. / ~ ~'~ APPROVED BY R~SE S~ BE REMO~O USE; RESIDENCE 17. THE SITE SHN_L BE GRADED TO CAUSE SURFACE WATER TO FLOW ZONED: HB AWAY ;'ROM THE RA~_lO EQUIPMENT AND TOWER AREAS. SlTEPLAN ~ PLANNING BOAI~D ~B. me SUBB~E S~ BE COMP^~ ~D BROUOm TO ^ SM~m ~ 1 ' I UNIFORM GRADE PRIOR TO FINISHED SURFACE APPUCATION. ~ o ~ ,-' TOWN OF SOUTHOLD ~. ~ EX~STING ,~ S~ER, WATER. ~. E~IC ANO OTHER ,;~ I I ~es. WHICH m~RE W~ THE EXEC~ON OF ~E WORK. 8EP ~ 0 B~ BE .EM~O ~D/OR ~'PED. PLDG.D OR OTHEr,BE DATE DISCONTINUED AT POINTS WHICH WILL NOT iNTERFERE WI~ THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF NOT COVERED BY THE PROPOSED IMPROVEMENTS SHALL BE RESTORED DETAIL REFERENCE PROPER'Pr LINE ~- AS REQUIRED. 21. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION,  ~. X X ; FENCE LINE SHALL BE IN CONFORMANCE WI~ THE LOCAL GUIDELINES FOR BECKONS AND DETAILS EROSION AND SEDIMENT CONTROL. -- E ELECTRIC SERVICE 22. ALL SITE WORK SHALL BE COORDINATED WITH THE PROPERTY OWNER CONCRETE T- TELEPHONE SERVICE AS REQUIRED. 25. CONTRACTOR;~EC~ONTACT DIG ALERT: 800-962-7962 TO LOCATE _ITIED PRIOR TO CONSTRUCTION. GRAVEL/STONE --~ EXISTING CONTOUR s~_ 312 9245 MAIN ROAD BETA 850/1900 C~,M F.A 850/19130 PROPOSED ~ ('nm) ~ SUPPOI~T POST + BRACKET FOR CHANNEL (PIROD INC OR EQUAL) CUT POST LENGTH TO SUIT BY REMOVING UNCAPPED END (PIROD PART NO. 852168 OR 85216 T HANGER BRACKET (PIROD INC OR EQUAL) MAXIMUM CABLE SP~J~ = 3'--0' (IYP) (PIROD PART NO. 802282) BRIDGE CHANNEL (PIROD INC. OR EQUAL) CUT ICE BRIDGE CHANNEL LENGTH TO SUIT (SEE NOTE) (PIROD PART NO. 8521B8 OR B521e3) CABLES ARRANGEMENT BY CONTRACTOR. FOR CABLE HANGER SEE TABLE BELOW INSTALL DRIP LOOP ON ANTENNA CABLES AT BOTTOM OF TOWER/MONOPOLE. BENDING RADIUS PER MANUFACTURER'S STANDARDS COMMSCOPE NOMINAL CABLE MANUP. MIN. CABLE: SIZE PART CABLE HANGER NUMBER PART NUMBER BEND RADIU: 7/8" F'XL107OPE 1070EZS 10" 1 1/4' FXL1480PE 1480EZS 15' 1 5/8" CR1973PE 1873EZS 20" PROPOSED BUFFER PROPOSED 16'x22' CINGUI AR LEASE DETAILED SITE PLAN SCALE: ~N NamW. BLUE/ GENERAL SITE NOTES: 1. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMO0~ UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. infinigy e n g i n e e r i n g__/ EAST MARION ~o ~.~ o~ ~_vo. ~ SITE NO. L1-1017 150--034 APPROVED BY PLANNING BOARD TOWN OF SOUTHOLD DATE SEPt 0 ~7 PIER CABLE ICE BRIDGE DETAIL /~UNISTRUT PIPE/CONDUIT CLAMP Pl119 OR P2558-35 (GALV.) (3YPICAL) BoLTFOLLOWToRQUEMM~UF' RECOMMENDATIONS FOR SCH.40 PiPE (GALV) UNISTRUT P1001 TO PROVIDE MOUNTING HARDWARE lO~e PLNN CONCRETE OR SAKRETE PIER- sc~ELEC/'rELCO~ SUPPORT RACK A INFINIGY ENGINEERING HAS NOT EVALUATED THE EXISTING TOWER FOR THIS SITE, IT iS THE CARRIER'S RESPONSIBIUTY TO JNVESllGATE ANY _OADING CONCERNS WHEN ADDING ADDITIONAL EQUIPMENT TO THE TOWER. SECTOR 1 - PROPOSED /~ RRE DEPARI}JENT A~IT~NNA UNIPOL~ / 0 ,wro~ ~ s~c~} I' ~ ,om ANTENNA LAYOUT APPROVED BY PLANNING BOARD I tOWN OF SOUrHO[D ANTENNA DETAIL MODEL #: ~ ~r~L CH~, u,~ F~CE-~ KATHREIN 800 10121 ~x~~m°~°s~ ~ GRADE LEVEL = O' (AGL) (BY Ol~ll~) P~ C~ ~ CI3a. k' SJ~/Z4¥ NE~ SOUTH ELEVA TION ~,o,EAST ELEVA TION ~To SCAt. E infini~o/V ,e,.E.W :i :'-,~, ,* engineering EAST MARION lar 300 ~EAT ON<S ~_V~.N.B~hr~S3E.Ny312,~Z03 SITE NO. L'-10179245__.0.~ v~c~ n¢-I u ~1"~' _._ 4'-0" GATE OPENING 1-I/2 PAIR INDUSTRIAL ),~d. LEABLE IRON OFFSET PIN HINGE (PAGE-WILSON M-6 OR COPPE~ BPdUD (1YP.) SEE GROUNDING DETAILS GATE DETAIL SCALE: NTS -~LE IRON FORK TYPE LATCH wrl~ PROVISION FOR PADLOCK (PAGE-WILSON ~'(PE 75 GATE LATCH ASSEMBLY OR EQU~L) I0'-0~ MAX. SPACING UNE POST (~'P.) END~ OR CORNER COATED CHAIN LINK TOP RAIL (TfP) 2~" CROWN ~.9 I.;1',-2 APPROVED BY L6- TOWN OF SOUTHOLD 3/8"e TRUSS ROD WrTH ~JRN BUCKLE. - 2 1/2" O.D, POST J Jill UNE PoST PLANNING BOARD ~T lO'-O- ,,u,,x. D^TE SEP 1_ 0 2007 SPACING FOR END, CORNER, & GATE POSTS CHAIN LINK FENCE DETAIL (ELEVATION)<~ SCALE: --2' CONC. GATE DETENT DETAIL METAL GATE DEFENT INSTALL WITH SLOTS PAP, Al I FI TO FENCE '~Hl~,,,tll~-~ rl~~ L~ BAR, I LOCK KEEPER. I LOCK KET~PER GUIDE. 2 LATCH FORKS. i ?~i LOCATED ~ DIRECTED BY 1HE OWNER. i .n f ! n~, j g ¥ EAST MARION · · ~ NEmW ~ ~ CONSTRUCTION e gin e ' g Xcmngular NO~ SET 1REE PLUMB PRIOR TO STAKING RUBBER HOSE SECIION TREE STAKING AND GUYING EASll~N RED CEDAR OYP) e4DIE~ PLANII~ NG~ I. STANDARDS SET FORTH IN 'A~ERIG&N STANDARD FOR NURSERY STOCK", LATEST EDmON, REPRESENT GUIDELINE SPEDEICAllONS ONLY AND SHALL CONST)TU1E MIN~UM QUALIFY REQUIREMENTS FOR PLANT MATERmAL 2. ALL PLANTS ARE SUBJECT TO THE APPROVAL OF THE ENGINEED'S REPRESENTATNE BEFORE, DURING, AND AFIER INSTALLAllON. 3. PRIOR TO CONS~UCIION, THE O~ITRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UI'ILITES AND ~ AVOID DAMAGE TO ALL UllLFFIES DURING COURSE OF THE WORK. THE CONIRACTOR IS RESPO~ K FOR BEPAIRING ALL BAIZE TO UTiLmES, STRUCTHRES, SITE APPUR1ENANCES, ETC. WHICH OCCURS AS A RESULT OF THE LANDSCAPE CONSTRUCTION. 4. ALL PLANTS IWUST BE HEALTHY, VIGOROUS MA1ERmAL, FREE OF PESTS AND DISEASE. 5. ALL P~S MUST BE CONTNBE~-GROWN OR BALLED AND BURLAPpED AS SPEGIFmED. 6. ALL TRE]ES UUST BE STRAIGHT 1RUNKED, FULL HEADED AND MEET ALL REQUIR~EI, ITS SPECIFIED. 7. ALL TREES MUST BE GUYED OR STA~'ED AS SHOWN. 8. ALL PLANTS AND PLANllNG AREAS UUST BE COMPLEIELY MULCHED AS SPECIFIED. 9. THE ENGINEER'S REPRESEI~ATNE ~ APPROVE THE STAKED LOCATION OF ALL PLANT MATERIAL PRIOR TO INSTALLAllON. lO, THE CONTRACTOR IS ~ FOR ~IFYING ALL OUANImES SHOWN ON THEBE PLANS B~E P~ClNG THE ~ 11. THE ~OR IS RESPONS)BLE FOR FULLY MNNTNNING ALL P[ANllNG (INCLUDING, BUT NOT MMITED TO: WATERING, SR~.YING, MULCHING, EERllEZATIOi~I, ETC.) OF PLANI1NG AREAS UNllL THE WORK IS ACC~q~ IN TOTAL BY THE ENOINEI~'S REPRESENTAllVE. 12. AFil~ BEING DUG AT THE N~RSEI~ SOURCE, AU. I~EES IN LEAF SHALL BE ACCUMATED FOR l~O (2) WEEKS UNDER A MIST SYSTEM PRIOR TO INSTALEAllON. 15. wNoE .P. LANT MATERIAL THAT DIES, 'IURNS BEOVtN OR DEFOLIATES (PRIOR TO TOTAL ACCEPTANCE OF THE K) SHALL BE PROMPTLY REMOVED FROM THE SO'E AND REPLACED W~ll-I MATERIAL OF THE SAME SPECIES, OBANTIIY. SiZE AND MEETING ALL SPECIFICAllONS, 14.. 1HE CONII~CTOR SHALL COMPEEII~y GUARANI'RE ALL PLANT MA1ERIAL FOR A PERIOD OF ONE (1) YEAR BEGINNINO AT THE BATE OF TOTAL ACCEPTANCE, THE CONTRACTOR SHALL PROMPTLy MAKE ALL REPLACEMENTS BEPORE OR AT THE END OF THE GUARANII[E PEPJOD. infinij en~inoerinB 150--034 EAST MARION SITE NO. L1-1017 92~ MAIN ROAD LANSCAPING PLAN CALLED NO~ APPROVED BY PLANNING BOAP. D TOWN OF SOUTHOLD D^TE SEP 1 0 201)7 · · · NEiW ~ '~ wU,!.-- v cmngr , ' 248~7 INYCENY'0,'7' Z0~ PLANT MATERIALS LIST ~ -,, DATE: , ~]:?j FEE: ~ ' ~ '-- 7~5-180~ 8AM TO 4PM FOR THE WIRELESS : FOLLOWING INSPECTIONS: .... 1. FOUNDATION . TWO REQU)RED ~ ,,, . FOR POURED CONCRETE OuCUP~CY OR~. ROUGH- FRAMING & PLUMBING 3. INSULATION SITE NUMBER: L1-1017 USE IS UNLAWFUL 4.FINAL- CONSTqUCT,ON MUST BE COMPLETE FOR C.O. ClNGU R ID: NYCENY1017 WiISOUT CERTIRCATE ,~ co~s,~uc,,o~ SITE NAME: EAST MARION OF OCCUPANCYYoRKREQUJREMENTSsTATEm NoTOFTHE CODESOFNEWREsPONSiBLE FOR DESIGN OR CONSTRUCTION ERRORS, INDEX R~ DIRECTIONS DRAWING I r.o. C,NOU~. OmC~ T*~ 4~ ~ST ~0 0.~ COUN~ .0.~ (C. S~) TO ~,N .0.~ S.-~S). r.O. , ~S I PROJECT INFORMATION TO~ TITLE SHE~ 6 SCOPE ~ WORK: AN UNMANNED TELECOMMUNICATION FACILITY INCLUDING THE INSTALLATION OF OUTDOOR EOUIP~ENT CABINETS AND (3) PANEL ANTENNAS MOUNTED C01 SITE P~N 6 ~TH~N UN,POLE C02 DETAILED SITE P~N AND B~AILS 6 S~rE *~.ESS: .~5 ~,* ~0.. ALL CONSTRUv ~ t0:~ SHALL ~ CO~ G~DING. EROSION & SEDIMENT CONTROL NOTES 6 ...... LAND O~E~: E~ST ~A~ON nRC DISm,C~ mm, OF THE C03 ELEVATION VI~S 6 A p.o. eox 1~1 C,. ~S E~ST ~*~oN. N~ .~}a " C~ CONSTRUCTION D~AILS 6 co~ CONST.UC~ON D~A~bS e ~*~ ,~ .u..~.: ~'-~-'"~' ~*¢~ - ~OF C~ CONSTRUCTION D~AILS 6 LATiTUdE (NAD 8~): 4~' 07' 40.1" ~ 'X~ C07 CONSTRUCTION D~AILS 6 ELEVAnON (NA~ 88): 32' AMSL j C08 CONSTRUCTION D~AILS 6 JU~SO~C~ON: TOWN Or SOU~OLD C~ ~NDSCAPE P~N 6 CU..ENT USE: F,.E STA~ON ; PROPOSED USE: TELECOMMUNICATIONS FACILITY E01 E~ERIOR GROUNDING P~N 6 CURRENT ZONING: SPLIT-ZONED HB AND R 40 E02 UTILI~ ROUTING P~N 6 [CCCTRtC CO~PAN~: UPA E~ ELECffELCO ONE-LINE AND PANEL SCHEDULE 6 TELEPHONE COMPANY: VERIZON E04 ANTENNA SCHEMATIC AND RF SCHEDULE 6 SITE OUALIFIOATION PARTICIPANT8 E05 E911 SCHEDULE AND BILL OF MATERIALS 6 E~ MISCEL~NEOUS D~AILS 6 A/[ dOHN STE~NS INFiNIGY ENGINEERING (518) 434-2288 EOEA A~RM DETAILS 6 SAC dOY MOONEY HIGHLANDER CONSULTANt, INC. (631) 581 8~05 n n EAST MARION NE , _~s_~ ~ ~ ~ ~ ~ ~ s,,,o.u.,o,, c,ngu I 6 B N/F CHERYL L. BONDARCRUK USE: RESIDENTIAL - 1 FAMILY RESIDENCE ZONED: R-40 ANTHON~F LENAIOS USE: RESIDENTIAL VACRAT LAND ZONED: R-40 N/F GEATRAKIS & GEORGE KORTSOLAKIS USE: RURAL RESIDENTIAL ZONED: R-~O \ N/F WHITE SWAN ~ USE: 1 FAMILY X RESIDENCE ZONED: R-40 N/F EASTERN BREEZES USE: 1 FAMILY * · ISITE PLAN IS NOT TO SCALE. ACTUAL FIELD CONDmON OF EXISTING BUILDING 51RUCTURE IS NOT WHAT IS DEPICTED ON THIS PL.~N. ClNCULAR COMPOUND AND TOWER SETBACK DIMENSIONS ARE TRUE FROM PROPER~¢ IJNES. SYLVIA M. DALEY USE: 1 FAMILY RESIDENCE ZONED: R-4-O SYMBOLS AND MATERIALS DETNL REFERENCE SECTIONS AND DETAILS CONCRETE EARTH GRAVEL/STONE infini,j engineering 150-034 RREHOgSE NOt METES AND BOUNDS ARE TAKEN FROM A SURVEY PERFORMED BY PECONIC SURVEYORS PC, UCENSED LAND SURVEYOR. S 85'40'00" W E.M. WAR MEMORIAL ASSOC. UllLIW POLE USE: RESIDENCE ZONED: HB 'T', SITE LEGEND CALL. NO ELECTRIC SERVICE TELEPHONE SERVICE --[~--- PROPOSED CONTOUR 50 EXISTING CONTOUR EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST NIARION, NY 119G9 cNE.w 'ngwU, J sr GENERAL NOTES: 1. SITE PLAN INFORMATION WAS WAS BASED ON VARIOUS SOURCES OF INFORMATION INCLUDING FIELD NOTES & MEASUREMENTS PERFORMED BY INFINIGY ENGINEERING, PLLC OF NY. 2. THIS PROPOSAL IS FOR AN UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF PANEL ANTENNAS MOUNTED TO A UNIPOLE, pLACEMENT OF SMALL, WEATHEEfflGHT RADIO EQUIPMENT CABINETS WITHIN THE SUBJECT LEASEHOLD, AND ASSOCIATED APPURTENANCES. 5. THE PROPOSED CINGULAR WIRELESS SERVICES FACILRY WILL BE UNMANNED AND DOES NOT REQUIRE WATER OR SEWER SERVICE. 4. THE PROPOSED CINGULAR WIRELESS SERVICE FAClLRY IS UNMANNED. AND IS NOT INTENDED FOR HUMAN HABITATION AND THUS DOES NOT REQUIRE HANDICAP ACCESS. 5. OCCUPANCY iS LIMITED TO PERIO01C MAINTENANCE AND INSPECTION BY ClNGULAR WIRELESS TECHNICIANS APPROXIMATELY (2) TIMES PER MONTH. 6. NO STROBIC LIGHTING IS INCLUDED IN THIS PROPOSAL. 7. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. 8. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 9. EXTERIOR SIGNS ARE NOT PROPOSED. 10. NO NEW ACCESS ROAD WILL BE REQUIRED UNDER THIS APPLICATION. 11. TOTN_ ASEA OF DISTURBANCE UNDER THIS PROPOSAL: 570 SF± 12. THE INCREASE iN STORM WATER RUNOFF DUE TO THE INCREASE IN IMPERVIOUS AREA IS INSIGNIFICANT. EXISTING DRAINAGE PA'rrERNS WILL NOT BE ALTERED. THEREFORE. DRAINAGE STRUCTURES ARE NOT PROPOSED. 15. ALL CONSTRUCTION FOR SITE IMPROVEMENTS SHN_L CONFORM TO APPLICABLE SPECIFICATIONS, STANDARDS, AND REQUIREMENTS OF THE GOVERNMENTAL OR UTIU1Y AUTHORITIES HAVING JURISDICTION. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK. SHALL BE PROTECTED AT ALL TIMES. AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK. SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILUNG AROUND OR NEAR UTILmES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFET~ D) TRENCHING & EXCAVATION 15.ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWING AND STIPULATED IN THE PROJECT SPECIFICATIONS. 16. IF NECESSARY, RUBBISH. STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 17.THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE RADIO EQUIPMENT AND TOWER AREAS. 18.THE SUBORADE SHALL BE COMPACTED ANO BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPUCATION. 19. ALL EXISTING IRACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTIUTIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORN, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUEO AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF ENGINEERING. 20. THE AREAS OF THE OWNERS PROPER1'( DISTURBED BY THE WORK NOT COVERED BY THE PROPOSED IMPROVEMENTS SHALL BE RESTORED AS REQUIRED. 21. EROSION CONTROL MEASURES. IF REQUIRED DURING CONSTRUCTION. SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDEUNES FOR EROSION AND SEDIMENT CONTROL. 22.ALL SITE WORK SHALL BE COORDINATED WITH THE PROPERTY OWNER AS REQUIRED. 25. CONTRACTOR TACT DIG ALERT: 800-962-7962 TO LOCA 'E 'lES PRIOR TO CONSTRUCTION. ,1:: s,rE BETA 850/ UMTS PROPOSED 16'x22' CINGULAR LEASE IN NEUTRAL BLUE/ TO PIPE MOU~ DETAILED SITE PLAN GENERAL SITE NOTES: 1. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO fiNISHED SURFACE APPUCATION. 2. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER ~TIUTIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUfRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EX~EME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTI!.~ES. CON~TOR SHALL PROVIDE SAFE~ ~AJNING FOR THE WORKING ENGINEER. 3. ALL EXISTING INACTNE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTIUTIES, WHICH IN~REERE WITH THE EXECU~ON OF THE WORK, SHALL BE REMOVED ANO/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WiTH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF AN ENGINEER. 4. THE SI~ SHALL BE GP~a~)ED TO CAUSE SURFACE WATER TO FLOW AWAY FROM ALL EQUIPMENT AND TOWER AREAS. 5. GARBAGE, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL DE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER.. 6. THE AREAS OF THE OWNERS PROPERT~ DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, FERTtLIZED, AND SEEDED. 150-034 EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST MARION, NY 11939 cNE.w 'ng J sr SUPPORT POST + BRACKET FOR CHANNEL (PIROD INC OR EQUAL) CUT POST LENGTH TO SUIT BY REMOVING UNCAPPED END (PIROD PART NO. 852168 OR 9 T HANGER BRACKET (PIROD lNG OR EQUAL) MAXIMUM c.~LE sPAN = ~'-o' ('~'P) (PIROD PART NO. 802262) ICE BRIDGE CHANNEL (PIROD INC. OR EQUAL) CUT ICE BRIDGE CHANNEL LENGTH TO SUiT (SEE NOTE) (PIROD PART NO. 852168 OR 852163) ARRANGEMENT BY CONTRACTOR. INSTALL DRIP LOOP ON ANTENNA CABLES AT BOTTOM OF TOWER/MONOPOLE. BENDING RADIUS PER MANUFACTURER'S STANDARDS COMMSCOPE NOMINAL CABLE MANUF. MIN. PART CABLE HANGER 8END RADIUS CABLE SIZE NUMBER PART NUMBER 7/8" FXLIO7OPE 1070EZS 10' 1 1/4' FXL1480PE 1480EZS 1 5/8" CR1973PE 1873EZS 20" FOR CABLE HANGER SEE TABLE BELOW PIER CABLE ICE BRIDGE DETAIL OR P2558-55 (GALV.) (1YPIC~d.) BoLTFOLLOWToRQUEIdANUF' RECOMMENDATIONS FOR SCH.40 PiPE (GALV) UNI~UT P1001 (GALV) UNISTRUT 10"~ PLAIN CONCRETE OR SAKRETE PIER ELEC/TELCOns SUPPORT RACK DETAILED SITE PLAN AND DETAILS 24897 NYCENYIO 7 C02 GRADING & EXCAVATING NOTES: <~ENERAL EROSION & SEDIMENT CONTROL NOTES: ~ V£OErATNE SCHEDULE 1. ALL EXCAVATIONS ON WHICH CONCRETE ~S TO BE PLACED SHALL BE SUBSTANTIALLY 1. THE SOIL EROSION AND SEDIMENT CONTROL MEASURES AND DETNLS AS SHOWN~ SPECIES RATE/lO00 S,F. DATE HERIN AND STIPULATED WITHIN STATE STANDARDS HORIZONTAL ON UNDisTURBED AND UNFROZEN SOIL AND BE FREE FROM LOOSE SHALL BE FOLLOWED AND INSTALLED IN A MANNER SO AS TO MATERIAL AND EXCESS GROUNDWATER. DEWATERING FOR EXCESS GROUNDWATER MINIMIZE SEDIMENT LEAVING THE SHALL BE PROVIDED IF REQUIRED. 2. PRIOR TO COMMENCING LAND DISTURBANCE ACI~V~Y, THE 2. CONCRETE FOUNDATIONS SHALL NOT BE PLACED ON ORGANIC MATER[N- IF SOUND UMITS OF LAND DISTURBANCE SHALL BE C~LY AND SOIL IS NOT REACHED AT THE DESIGNATED EXCAVATION DEFITI, THE ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR TALL FESCUE GRASS 1.0~ APRIL 1 - OCTOBER 15 UNSATISFACTORY SOIL SHALL BE EXCAVATED TO ITS FULL DEPTH AND EITHER BE OTHER APPROPRIATE MEANS. REPLACED WITH MECHANICALLY COMPACTED GRANULAR MATER,S.. OR THE .3, EROSION CONTROL DEVICES SHALL BE INSTALLED BEFORE GROUND SERICEA LESPEDEZA SEED BEARING HAY140~ OCTOBE:E I - ~ARCH 15 EXCAVATION BE FILLED WITH CONCRETE OF THE SAME QUALRY SPECIFIED FOR THE DIS3~RBANCE OCCURS. THE LOCATION OF SOME OF THE EROSION WlTH OVERSEEDING WEEPING LOVEGEASS 0,2· MARCH 15 - NAY 1 FOUNDATION. CONTROL DEVICES MAy HAVE TO BE ALTERED FROM SHOWN ON THE 3. ANY EXCAVATION OVER THE REQUIRED DEPTH SHALL BE FILLED WITH EITHER APPROVED PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE FERTILIZER MIX : MECHANICALLY COMPACTED GRANULAR MATERIAL OR CONCRETE OF THE SAblE DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PA'r~ERNS. IT IS THE QUALRY SPECIFIED FOR THE FOUNDATION. CRUSHED STONE MAY BE USED TO CONTRACTOR'S RESPONSIBILITY TO ACCOMPUSH EROSION CONTROL FOR APPLICATION N, #/ACRE P2 Os, ~J/ACRE K2 O, ///ACRE N, TOP STABIMZE THE BOTFOM OF THE EXCAVATION. STONE, iF USED, SHALL NOT BE USED ALL DRAINAGE PATTERNS CREA]ED AT VARIOUS STAGES DURING CONSTRUCTION. ANY DIFFICULTY IN CONTROLUNG EROSION DURING ANY PHASE OF 1st 60 - 90 120 - 180 120 - 180 50 AS COMPIUNG CONCRE]E THICKNESS. CONStrUCTION Sf-[ALL BE REPORTED TO THE ENGINEER IMMEDIATELY, 4. AF'I[R COMPLETION OF THE FOUNDATION AND OTHER CONSTRUCTION BELOW 4. THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES 2nd 60 120 120 - GRADE, AND BEFORE BACKFILLING, ALL EXCAVATIONS SHALL BE CLEAN OF MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE UNSUITABLE MATERIAL SUCH AS VEGETATION, TRASH, DEBRIS, AND SO FORTH, PLANS IF DP, AIRAGE PATFERNS DURING CONSTRUCTION ARE NO~E: DIFFERENT FROM THE FINAL PROPOSED DR. NNAGE PAT[ERNS. - GP~S AND MULCH ALL DISTURBED AREAS 5. -USE APPROVED MATERIALS CONSISTING OF EARTH, LOAM, SANDY CLAY, SAND ANY DIFFICUL1Y IN CONTROLMNG EROSION DURING ANY PHASE -BE FREE FROM CLODS OR STONES OVER 2-1/2' MAXIMUM DIMENSIONS OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER -BE PLACED IN 6" LAYERS AND COMPACTED TO 95~ STANDARD PROCTOR IMMEDIATELY. EXCEPT IN GRASSED/LANDSCAPED AREAS, WHERE 90~ STANDARD PROCTOR 5. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL MEASURES UNTIL WHEN I-hI:)RAUEC SEEDING AND FERTIEZING EQUIPMENT IS USED, NO GRADING AND SHAPING OR PERMANENT VEGETATION HAS BEEN ESTABUSHED. CONTRACTOR SHALL SEEDBED PREPARATION WILL BE REQUIRED, THE FERrlEZER, SEED AND WOOD CELLULOSE FIBER CLEAN OUT ALL SEDIMENT PONDS WHEN REQUIRED BY THE ENGINEER OR MULCH WILL BE MIXED WITH WATER AND APPUED IN A SLURRY. ALL SLURRY INGREDIENTS MUST 6, REMOVE ALL VEGETATION, TOPSOIL, DEBRIS, WET AND UNSATISFACTORY SOIL THE LOCAL JURISDICTION INSPECTOR. CON3RACTOR SHALL INSPECT EROSION BE COMBINED TO FORM A HOMOGENEOUS MIXTIJRE, AND SPREAD UNIFORMLY OVER THE AREA MATERIALS, OBSTRUCTIONS. AND DE~RIOUS MATERIALS FROM GROUND SURFACE CONTROL MEASURES AT THE END OF EACH WORKING DAY TO ENSURE WITHIN ONE HOUR AFTER MIX~JRE IS MADE. STI~AW OR HAY MULCH AND ASPHALT EMULSION PRIOR TO PLACING FILLS. PLOW, STRIP, OR BREAK UP SLOPED SURFACES S3EEPER THAN MEASURES ARE FUNCTIONING PROPERLY. WILL BE APPLIED WI~{ BLOWER-TYPE MULCH SPREADING EQUIPMENT WIthIN 24 HOURS AFTER ~HAN 1 VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING SURFACE. SEEDING, THE MULCH WILL BE SPREAD UNIFORMLY OVER THE AREA, LEAVING A~OUT 25 WHEN SUBGRADE OR EXISTING GBOUND SURFACE TO RECEIVE FILL HAS A DENSITY LESS 6. THE CONTRACTOR SHALL REMOVE ACCUMULA'IED SILT WHEN PERCENT OF THE GROUND SURFACE EXPOSED. THAN THAT REQUIRED FOR FILL, BREAK UP GROUND SURFACE TO DEPTH REQUIRED, THE SILT IS WITHIN 12' OF THE TOP OF THE SILT FENCE. PULVERIZE, MOISTURE-CONDmON OR AERATE SOIL AND RECOMPACT TO REQUIRED 7. FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL EROSION CONVI~ON~ SEE'~NG EOUIPM~R' DENSRY. CONTROL MEASURES WILL RESULT iN ALL CONSTRUCTION BEING STOPPED ON THE JOB SITE UNTIL SUCH MEASURES ARE GRADE, SHAPE AND SMOOTH WHERE NEEDED TO PROVIDE FOR SAFE EQUIPMENT OPERATION AT 7. PROTECT EXISTING GRAVEL SURFACING AND SUBGRADE IN AREAS WHERE EQUIPMENT LOADS CORRECTED. SEEDING TIME AND FOR MAINTENANCE PURPOSES. THE EME AND FER~rlUZER iN DRY FORM WILL BE SPREAD UNIFORMLY OVER THE AREA IMMEDIATELY BEFORE SEEDBED PREPARATION, A WILL OPERATE. USE PLANKING OR OTHER SUITABLE MATERIALS DESIGNED TO SPREAD EQUIPMENT 8. SILT BARRIERS TO BE PLACED AT DOWNSTREAM TOE OF ALL SEEDBED WILL BE PREPARED BY SCARIFYING TO A DE~TI-I OF 1 TO 4 ~NCHES AS DETERMINED LOADS. REPAIR DAMAGE TO EXIS~NG GRAVEL SURFACING OR SUBGRADE WHERE SUCH CUT AND FILL SLOPES. ON SITE. THE SEEDBED MUST BE WELL PULVERIZED, SMOOTHED AND FIRMED. SEEDING WILL DAMAGE IS DUE TO THE CONTRACTOR'S OPERATIONS. OAMAGED GRAVEL SURFACING SHALL BE RESTORED TO MATCH THE ADJAC:ENT UNDAMAGED GRAVEL SURFACING AND 9. ALL CUT AND FILL SLOPES MUST BE SURFACED ROUGHENED AND BE DONE WITH CULTIPACKER-SEEDER, DRILL, ROTARY SEEDER OR OTHER MECHANICAL OR HAND SHALL BE OF THE SAME THICKNESS. VEGETATED WITHIN SEVEN (7) DAYS OF THEIR CONStrUCTION. SEEDER. SEED WILL BE DIS~IBUTED UNIFORMLY OVER A FRESHLY PREPARED SEEDBED AND COVERED EGHTLY. WITHIN 24 HOURS AFTER SEEDING, STRAW OR HAY MULCH WILL BE SPREAD 10. CONTRACTOR SHALL REMOVE ALL EROSION & SEDIMENT CONSOL UNIFORMLY OVER THE AREA, LEADING A~OUT 25 PERCENT OF THE GROUND SURFACE EXPOSED. 8. REPLACE EXISTING GRAVEL SURFACING ON AREAS FROM WHICH GRAVEL SURFACING IS MEASURES AFTER COMPLETION OF CONSTRUCTION AND MULCH WILL BE SPREAD WITH BLOWER--TYPE MULCH EQUIPMENT OR BY HAND AND ANCHORED REMOVED DURING CONSTRUCTION OPERATIONS. GRAVEL SURFACING SHALL BE REPLACED ESTABUSHMENT OF pERMANENT GROUND COVER. IMMEDIATELY AFTER IT IS SPREAD. A DISK HARROW WITH THE DISK SE'i' STRAIGNT OR A SpECiAL TO MATCH EXISTING ADJACENT GRAVEL SURFACING AND SHALL BE OF THE SAME 11. THE ESCAPE OF SEDIMENT FROM THE SITE PACKER DISK MAY BE USED TO PRESS THE MULCH INTO THE SOIL THICKNESS. SURFACES OF GRAVEL SURFACING SHALL BE FREE FROM CORRUGATIONS ANO WAVES. SHALL BE PREVENTED BY THE INSTALLATION OF EROSION CONTROL EXISTING GRAVEL SURFACING MAY BE EXCAVATED SEPARATELY AND REUSED IF INJURIOUS MEASURES AND PRACTICES PRIOR TO. OR CONCURRENT WITH, AMOUNT~ OF EAEffH, ORGANIC MATrER, OR OTHER DELETERIOUS MATERIALS ARE REMOVED LAND-DISTIJRBING ACTIVITIES. PRIOR TO REUSE. FURNISH ~ ADDITIONAL GRAVEL RESUREACtNG MATERIAL AS REQUIRED. BEFORE GRAVEL SURFACING IS REPLACED, SUBGRADE SHALL BE GRADED TO CONFORM TO REQUIRED SUBGRADE ELEVATIONS, AND LOOSE OR DISTURBED MATERIALS SHALL BE THOROUGHLY COMPACTED. DEPRESSIONS IN TI-IR SUBGRADE SHALL BE FILLED AND COMPAC3ED WITH APPROVED SELECTED MATERLN- GRAVEL SURFACING MATERIAL MAY BE USED FOR FILUNG DEPRESSIONS IN THE SUBGRADE, SUBJECT TO ENGINEER'S APPROVAL. 9. DAMAGE TO EXISTING STRUCTURES AND UTILITIES RESULTING FROM CONTRACTOR'S NEGUGENCE SHALL BE REPAIRED/REPLACED TO OWNER'S SATISFACTION AT CONTRACTOR'S EXPENSE. 10. CONTRACTOR SHALL COORDINATE THE CONSTRUCTION SCHEDULE WITH PROPERTY OWNER SO AS TO AVOID INTERRUPTIONS TO PROPERTY' OWNER'S OPERATIONS. 11. ENSURE POSITIVE DRAINAGE DURING AND AFTER COMPLETION OF CONSTRUCTION. ! 12, ALL CUT AND FILL SLOPES SHALL BE MAXIMUM 2 HORIZONTAL TO 1 VERTICAL 13. CONTRACTOR SHALL BE RESPONSIBLE EOn MONITORING SITE VEHICLE TRAFFIC AS TO NOT ALLOW VEHICLES LEAVING THE SITE TO TRACK FOR CLEANING PUBMC STREETS DUE TO MUDDY VEHICLES LEAVING THE SITE. ' r~engineering ~c i r~ ' ~C~y EASTMARION NElar o..,.--- _.___----- ...-- - ~,,,£__ SITENO. U-1017 c nc,u ,._ ._.__ ,~=(~,).~-2o.,150__034 EASTMARION. NY11939 ~/ WIRELESS ~ I~A~ REVISICN~ BY CHKI~p'~ dOB f $~Ef D~AVaNGNUMSER [R~EV SCA~ ID~NED= I DRAWN: 24897 INYCENYI0171 C02A IINFINIGY ENGINEERING HAS NOT EVALUATED THE EXISTING TOWER FOR THIS SITE. IT IS THE CARRIER'S RESPONSIBILITY TO INVESTIGATE ANY LOADING CONCERNS WHEN ADDING ADDITIONAL EQUIPMENT TO THE TOWER. SECTOR 5 - 250t SECT~ I - 30' I/OOEI_ I~ 1~THREIJV ~00 tO12t ANTENNA LAYOUT PROPOSED 6' BLACK VINYL CHAIN UNK engc g 150-034 EAST MARION SITE NO. L1-1017 9245 MAiN ROAD EAST MARION, NY 11939 LOCATION OF GPS ANTENNA MOUNTED TO H-FRAME )= 32' (AMSL) GRADE LEVEL = O' (AGL) (m' Om~S) AREA (1) ANTENNA Pl~ SECTOR PROPOSED 6' BLACK VINYL CHNN UNK FENCE GRADE LEVE~SL) ~ GRADE LEVEL '-'~' (AGL) ~ ~TOW~R FOUNDAllON DESIGN (~ ~) NOTE: CONCRETE AND REINFORCING STEEL NOTES: COMPACT SOIL TO MIN 95~ MODIFIED MAX DENSITt' PER 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ALPHA 2. CONCRETE SHA" HAVE A MiNiMUM COMPRESS S,"ENGTH OF BATTERY 24 VD(:: 850/190 ~50/190 4000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE.* CABINET MCPA , ALL CONCRETE EXPOSED TO FREEZING WEATHER SHALL CONTAIN ENTRAINED AIR PER ACI 211 AND TABLE 4,2.1 OF ACl 518-95. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED 8' THICK CONCRETE UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM EQUIPMENT PAD A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPMCES ~ SHALL BE CLASS 'B" AND ALL HOOKS SHALL BE ACI STANDARD, UNO. ~ ~ REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: SLOPE ~-. THE FOM_OWlNG MINIMUM CONCRE'TE COVER SHALL BE PROVIDED FOR PAD---~ " CONCRETE: CAST AGNNST EARTH ........ 5 IN. '~, I CONCRETE EXPOSED TO EARTH OR WEATHER: C~.l~. o.c. EA WAY L_EX~VA~ AB RED,,RED TOR~oVE CONCRL-IE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: CENTER OF SLAB VEGETATION AND TOPSOIL, AND P!.~E MIN 4' CRUSHED STONE SLAB AND WALL ........................ 3/4 IN. BEAMS AND COLUMNS .............. 1 1/2 IN. 5. A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, ELEVATION VIEW UNO, IN ACCORDANCE w~'rH ACl 501 SEC~]ON 4.2.4. 6. INSTALLATION OF CONCRL~I~ EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT NOKIA BTS CABINETS SET BY DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR NOKIA pER MANUFACTURER'S ENGINEERING APPROVAL WHEN DRILUNG HOLES IN CONCRETE. ~ SITE WORK GENERAL NOTES: -- 2. ALL SITE WORK SHALL BE COMPLETED AS iNDICATED ON THE DRAWINGS AND PROJECT SPECIFICATIONS. BATFERY ALPHA BETA GAMMA 5. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER CABINET 24 VDC 850/1900 850/1900 860/1900 MCPA REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY, BTS BTS BTS CABINET I I 4. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY i FROM THE BTS EQUIPMENT AND TOWER AREAS. ~ ~ ~ u'[: ~ B..o .~ OR EM~KME~ ~TER~ S~ BE P~CED ON FROZEN ~ ? ,, ~' I 6. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH ,? ? ? /' I UNIFORM GRADE PRIOR TO FINISHED SURFACE APPUCATION. ~ ~------' ~----~"I 7. THE AREAS OF THE OWNER'S PROPER~Y D~STURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY. SHALL BE GRADED i TO A UNIFORM SLOPE, AND STABIUZED TO PREVENT EROSION. ARGus ,NET SET 7: DATIONS \ GENERAL CONTPJ~:TOR PER B. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING MANUFACTURER'S RES CONSTRUCTION, SHALL BE ,N CONFORMANCE WITH THE LOCAL GUIDEUNES FOR EROSION AND SEDIMENT CONSOL. 9. SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND THOSE LOCAL AUTHORITIES HAVING PLAN VIEW ~ ~ 150-054 ALPHA 850/190( GAMMAl 24 VDC 850/190~1 CABINET ~50/190 MCPA 3NCRETE  GPSfBCCH (SEE NOTE 4)~ I~ USE: (PART NO. S~MR) CABLE DIAMETER VS. LENGTH SFX540PE (1/2--INCH) UP TO 70' FXLIO7OPE (7/8-INCH) UP TO 120' FXL1480PE (1 1/4-INCH) UP TO 170' CR1875PE (1 5/8-INCH) UP TO 200' NOTE: FOR LARGER DIA CABLE, USE 6' JUMPERS AT 1/2' DIA. AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25~ OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANIENNA. 2. ALL GPS ANTENNA LOCA330NS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCA310N OF GPS ANTENNA. 5. THE WEIGHT OF THE ANTENNA MOUNT IS 6.5 LBS. 4. IF ICE BRIDGE OR SIMILAR POST IS NOT GROUNDED, GROUND WffH ~/2 AWG TINNED BARE COPPER WIRE EXOTHERMICALLy BONDED TO POST AND CONNECSED TO GROUND RING. SUPPORT~ m FOR LMU/GPS SENSORS 30-5/16' 30-5/16' 2-19/52" 24-~3/52" //--(4)-5/8" MOUNTING HOLE R~0NT 29-5/8' 24-13/52' 5-29/32' (PUNT~) FRONT ~/Is' BOLT HOLE MEASUREMENTS FOR A 24VDC OUTDOOR SITE BOLT HOLE MEASURF~MENTS FOR A IdCPA OUTDOOR CABINET ANCHOR LOCATION DIAGRAM~ ALBN~f. NY 12207 150-034 EAST MARION SITE NO. U-1017 9245 blAIN ROAD · SUBCON33~N~TOR TO INSTALL ISOLATION PAI)S UNDERNEATH THE CABINETS WHEN MOUNTING 3E21 AND OR TE20 TO CONCREE cNE.w lng wU, J sr , CONSTRUCTION DETAILS ~BCCH/GPS ANTENNA MOUNTED TO COAX TRANSITION ALL CONDUITS TO SUPPORT POST ,3/4" LMFC AT NOKIA BTS UNITS~ (2)-1/2"C0AX JUMPERsDIA E911\r- .................. 24VDC 3-FT MAX FROM /--JUMPER TERMINATION X /AT NOKIA BTS - -- - ~-- Z '-~ '~- ~ GAMMA BTS BETA BTS ALPHA BTS ~J'~ LAST J J J J JJ ' '-- ~ " R TO C ' ' J : ~OUND JJ I Ii ;, I I J 24VDC 24-~8 AND , , * , I ~R NOKIA H~A JJ I"II i~ J~ , UNISTRUT ANGLE J J J J CIRCUITS 6-~4, JJ I Il ~J I I J BRACKg AND (SIDE VIEW) i ~ MCPA ~ _ I ~ ~ ~ ~ GROUND ~ ~ = ~ ~ ~ BOLTS SUPPORT F~ME AT R~R OF NOKIA POWER CABIN~ SUPPORT F~ME DETAIL infinigy. *STMARIONgu"arl ,:,-- --- CONSTRUCTION ~: I ~N/D: J ~: 2~g7 NYOENY10~ 71 GATE OPENING 1-1/2 PAiR INDUS3~IAL MALLEABLE IRON OFFSET PIN HINGE (PAGE-WILSON M-6 OR EQUAL) -- BLACK VINY'L COATED CHNN LINK- (TYP.) SEE GROUNDING DET. edLS GATE DETAIL SCAL~ NTS I,,I IRON FORK 3YPE LATCH WITH PEOVISION FOR PADLOCK (PAGE-WILSON 3YPE 75 GATE LATCH ASSEMBLY OR EQUAL) I0'-0' MAX. SPACING '- UNE POST (~YP.) RAIL CPfP) -- 2' MESH, 9 GAUGE GALV. BI~CK VINYL COATED CHAIN LINK · 2 1/2' O.D. POST · I ~r[, BO'FrOM TENSION WIRE III1UNE PoST t rcrJ, CONCR C~HA.~IN LINK FENCE DETAIL (ELEVATION) ~:> -2' CON CROWN M~~'~AL GATE DETENT iNSTALL wm-t SLOTS FINISH GRADE PARALLEL TO FENCE -'11~ L ',~.~ :ii CONCRETE GATE DETENT DETAIL infinity engineering gg PINE ~ 150-034 EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST MARION. NY 11939 GATE/STOPPER DETAIL v c ngular WIRELESS 1. FENCING MATERIALS SHALL BE OF GALVANIZED STEEL 2. POST, BP, ACES AND GATE FRAMES SHALL BE SCHEDULE 40 (STANDARD WEIGHT) PIPE. SIZES SPECIFIED ARE ~ 3. DOUBLE SWING GATE SHALL BE PROVIDED WITN TUBULAR PLUNGER BAR, I LOCK KEEPER, 1 LOCK KEEPER GUIDE, 2 LATCH FORKS, 2 FORK CATCHES, 1 CATCH FOR PLUNGER BAR, AND 2 GATE STOPS LOCATED AS DIRECTED BY 3~iE OWNER. 4. POSTS, CAPS AND OTHER NECESSARY FENCE FITrlNGS SHALL BE AS MANUFACTURED BY THE FENCE MANUFACTURER OR EQUAL. HINGES SHALL BE OF GALVANIZED STEEl_ 5. POSTS SHALL BE SPACED EQUIDISTAkq' BUT NOT MORE 6. BOTTOM OF FENCE SHALL BE NO MORE THAN 5' GRADE AT ANY SECTION. CONSTRUCTION DETAILS 24897 NYCENY 017 C07 I MIN MIN FENCE- WHERE REQUIRED 3YPE C SILT F.~RIC ON UPSTREAM SIDE OF FENCE DIRECTION OF FLOW 150-034 NOTE: 1. DIG TRENCH 2. LAY IN FABRIC TO BoTroM OF TRENCH 3. BACKFIM. TRENCH, COVERING FABRIC SILT FENCE DETAIL CONSTRUCTION NOTES FOR FABRICATED SILT FENCE WOVEN WIRE FENCE TO BE FASTENED SECURELY POSTS: STEEL E~'IER T OR U TO FENCE POSTS WITH WIRE TIES OR STAPLES. ~E. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24' AT TOP AND MID SECTION. FENCE: WOVEN WIRE, 14 GA. 6' MAX. MESH OPENING. AS DIRECTED BY BANKS CO. WHEN ~ SECTIONS OF FILTER CLOTH N~JOIN EACH OTHER THEY SHN.L BE OVER- LAPPED BY SIX INCHES AND FOLDED. FILTER CLOTH: FILTER X, MIRAR lOOX' STABlUNKA T140N OR APPROVED EQUAL MNNTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN "BULDGES' DEVELOP IN THE SILT FENCE, PREFABRICATED UNIT: GEOFAB, ENVIROFENCE OR APPROVED EQUAL ALL SILT FENCE MATERIALS MUST BE USTED ON THE CURRENT STATES. D.O.T. QUALIFIED PRODUCTS UST ~36. EAST MARION SITE NO. L1-1017 9245 MAIN ROAD cNE=w wU,.[ sr UNK F~*4CE STONE SURFACE SECTION THROUGH COMPOUND CONSTRUCTION DETAILS 24897 NYCENY1017 ~ I TREE STAKING AND GUYING NOT TO SCALE RED CEDAR 1. STANDARDS SET FORTH IN "AMERICAN STANDARD FOR NURSERY STOCK", LATEST EDITION, REPRESENT GUIDEUNE SPECIFICA110RS ONLY ARD SHALL CONSTffUTE MINIMUM QUALI~ REQUIREMENTS FOR PI. ANT MATERIAL. 2. ALL PLANTS ARE SUBJECT TO THE APPROVAL OF THE ENGINEER'S REPRESENTAINE BEFORE, DURING, AND AFIER INSTN. J.A'flON. 5. PRIOR TO CONSTRUCRON, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUNO URLmES AND SHALL AVOID DAMAGE TO ALL URLmES CURING COURSE OF THE WORK. '(HE CONTRACTOR IS RESPONSIBLE FOR REPNRING ALL DAMAGE TO UTILmES, STRUCTORES, SITE APPUETERANCES, ETC. WHICH OCCURS AS A RESULT OF THE LANDSCAPE CONSTRUCTION, 4, AU. PLANTS MUST BE HEALTHY, VIGOROUS MATERIAL, FREE OF PES1S AND DISE~E, 5. NJ_ PL~ MUST BE CONTNNER-GROWN OR BALLED AND BURL,~PBED AS SPECIFIED, 6. AU. TREES MUST BE EI~AIGHT THUNKED, FULL HEADED AND MEET ALL REQUIREMENTS SPECIRFO. 7, ALL TREES MUST BE GUYED OR STAKED AS SHOWN. B. NJ. PLANTS AND P!_ANRNG AREAS MUST BE COMPLETELY MULCHED AS SPECIRED. 9. THE EMGINE£R'S R£PRESENTA'I~E WILL ARPRO~E THE STAKED LOCATION OF ALL PLANT MATERIAL PRIOR TO INSTAL[A~N. 10. THE COhff~ACTOR IS RESPONSIBLE FOR VERIFYING N.L OUARTmES SHO~N ON THESE PLANS BEFORE PRICING THE WORK. 11. THE CON'~CTOR iS RESPONSIBLE FOR FULLY MAINTNNING NJ_ PLANTING (INCLUDING, BUT NOT UMI'i'F_.D TO: WATERING, SPRAYING, MULCHING, FERTILIZATION, ETC.) OF PLAN~ING AREAS UNTIL THE WORK IS ACCEPTED IN TOTAL BY THE ENCINEER'S REPRESE~ITATIVE. 12. ~ BEING DUG AT THE NURSERY SOURCE, ALL TREES IN ~ SHALL BE ACCUMATED FOR lWO (2) WEEKS UNDER A MIST SYSTEM PRIOR TO INSTALLATION. 13. ANY PLANT RA~ERtAL THAT DIES, TURNS BRO~ OR DEFOtJATES (PRIOR TO TOTAL ACCEPTANCE OF THE WORK) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPtJ~C£D WR1J MATERIAL OF THE SAME SPECIES, OUAN'flTY, SIZE AND MEE'DNG NJ. SPECIFICATIONS, 14. THE CONTRACTOR SHALL COMPLE[ELY GDAP~NTEE ALL PLANT MATER~I_ FOR A PERIOD OF ONE (1) 'fEAR BEGINNING AT THE DAlE OF TOTAL ACCEPTANCE. THE CONTRACTOR SHALL PROMPTLY 14AKE ALL REPLACEMI~ITS BEFORE OR AT THE END OF THE GUARANIEE PERIOD, LANSCAPING PI-4N iegg ifn ! er?i!g~y.P,N~ 150-034 EAST MARION SITE NO. L1-1017 cNE.w 'ngwU, J sr LANDSCAPE PLAN PLANT MATERIALS LIST CODED DRAWING NOTES CO,,ECT FENCE TO ~ROU,D mN~. ~ ~. P~ES. BOND UI1LIIY RNTX SUPPORT POST 10 E~UlPMENT GROUND RIN~ w~ t2 AW~. COIL IO-FT t2 AWG GROUND WIRE FOR NOKIA B~S 2 AWG GROUND ~lRE FOR MCPA & UMTS 2 AWG GROUND WIRE ~02R 24VDC CABINET & BATIERY CABINET CABINET A -- OF MASTER AND BOTTOM /.~. GROUND BARS. BOND ALL COAX CABLES WITH COAX GROUND KITS EQUIPMENT GROUND BAR TO GROUND RING (~YP 2 PLACES) P~OPOSED UNIPOLE ~ BOND ALL METALLIC OBJECTS TO GROUND BAR EXTERIOR GROUNDING PLAN ifni2, i g Y 50-034 EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST MARION, NY 11939 LEGEND 1- COPPER GROUND BAR, 1/4"X 4'X 20', NEWTON INSTRUMENT CO. CAT. NO. B-6142 OR EQUAL HOLE CEN~ERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 2- INSULATORS, NEWTON INSTRUMENT CAT. NO. 5061-4 OR EQUAL 5- 5/8' LOCKWASBERS, NEWFON INSTRUMENT CO. CAT. NO. 5015-8 OR EQUAL 4- WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR EQUAL 5- 5/8-11 X 1' HHCS BOLTS. NEWTON INS'I~UME~T CO. CAT NO. 5012--1 OR EQUAL 6- INSULATORS SHALL BE EUMIRA~ED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNEC~ON TO TOWER/MONOPOLE ~IRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. GROUND BAR COPPER-CLAD STEEL GROUND ROD ~- 5/8'e~ 0'-0' LONG cNEmW 'nggJ. sr GROUNDING NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL OTHER APPLICABLE LOCAL CODES 2, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION SO AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 5. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). 4. ALL GROUND CONNECTIONS ABOVE GRADE SHALL BE FORMED USING 2-HOLE LUGS AND ~/0 (2) HIGH PRESS CRIMPS. 5. ALL EXOTHERMIC MECHANICAL CONNECTIONS TO THE GROUND RODS SNAIL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 6. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 7, ALL EXTERIOR GROUND CONDUCTORS SHALL BE ~2 SOLID AWG TIN PLATED COPPER UNLESS OTHERWISE iNDICATED. 8. IF APPECABLE: GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8'e lO-FT. LONG, AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18' BELOW FINAL GRADE. 9. CONNECTIONS TO THE GROUND BARS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SLOES OF THE GROUND BAR ARE PERMITTED. 10, USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 11, MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 10 OHMS. 12. NO UPHILL GROUND CONNECTIONS ALLOWED ABBREVIATIONS AWG AMERICAN WIRE GAUGE BCW BARE CoPPer WIRE DWG DRAWING EMT ELECTRICAL METALLIC TUBING GEN GENERATOR IMC INTERMEDIATE METALLIC CONDUIT MGB MASTER GROUND BAR PCS PERSONAL COMMUNICATION SYSTEM PVC POLYVINYL CHLORIDE CONDUIT PVC RIGID GALVANIZED STEEL ELECTRICAL SYMBOLS GROUND ROD WITH ACCESS CHEMICAL GROUND ROD GROUND ROD DISCONNECT SWITCH METER CIRCUIT BREAKER CADWELD TYPE CONNECTION COMPRESSION TYPE CONNECTION RWY RACEWAY ~-m[~ R~ c~ ~/~ - REPRESENTS DETAIL NUMBER , ELECTRICAL NOTES ~ ~ (1) ~" ~C FOR B~A/~ 3. ~ [~1~ ~S S~LL BE u.g ~PRO~D OR U~D ~t ~B~ ~ ~ ~(~ '~ XX X~///' X 5. CO~OR S~ OBTNN ~ PERM., PAY ~ PERMff ~ES, H~A CIRCU~ (6) ~14~' ~ ~~/ ~x ~D S~EDU~ ~ REQUIR~ INSPE~ONS. UTILI~ ROUTING P~N ~ ~ ~m . (~D OR ~E SOIL) 'ELCO CONDUff UTILI~ T~NCH DETAIL ¢ EAST MARION NE ' : "-~ ~ ~ ~ ~ ~ ~ ~ ~ I~ ROUTING P~N 1) STANDN~D 42-POSITION INTERSECT PANEL SHALL ALWAYS BE USED WHERE POSSIBLE pART t~MM5320042-3R 2) ORDER b~F/NJ INTERSECT BRF~KER KIT PART~BRKEB KIT TS TO ORDER A GENERATOR RECEPTACLE ON THELEET S)DE OF THE PANEL, ORDER PART ~DRINWIRREL~Y-L AND APPLETON REDEPTACLE PART ~J~2004'4-RS FOR 3-PH FOR A GENERATOR BECEPTABLE ON THE RIGHT ORDER pARIF ~CR,HW,RRELAY-R ANDAPPLETON RECEPTADLE PARq- ~AN20044-RS FOR 5-PH. PANEL 'A' SCHEDULE L ELEC/'rELCO/ALARM ONE LINE DIAGRAM i n f ! j g ye n , in e i 150-034- EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST MARION, NY 11939 cNE.w rang wUJ sr MCPA PANEL 'A' SCHEDULE (~ SCN.E:N~J NOTES: 1) 24VDC CABINET INSTALLER SHALL MAKE ALL FINAL TERMINATIONS AT 24VDC CABINET 2) NOKIA INSTALLER SHALL MAKE ALL RNAL TERMINATIONS AT NOKIA B~S CABINET 3) 24V0C CABINET MANUFACTURER SHALL PROVIDE AND INSTALL BRIDGE KIT FROM 24VDC CABINET TO NOKIA BTS CA~INET 4) 24-VDC MANUFACTURER SHALL PROV1DE AND INSTALL DC POWER CABLES READY FOR FINAL TERMINATION BY NOKIA. DC DISI~RIBUTION CABLES SHALL BE (2)-2/0 AWD FOR EACH STS. A) ASSOCIATED CIRCUIT BREAKER FOB DC OISTRIBUTION CABLES SHALL BE LEFT OPEN AND PROVlDED W/A REMOVABLE LOCKING DEVICE OR TAG $0 THAT THE BREAKER CAN NOT BE CLOSED* B) DC CABLES SHALL BE RHB/RHW AND CABLE TRAY (CT) RATED C) NOKLA INSTALLER TO PROVIDE DC DISTRIBUTION CABLES LUGS ON NOKIA END S) 24VDC INSTAM.ER SHALL PRO~IDE AND INSTALL TELCO CABLE(S) BELDEN PANT ~7919A COILED AND READY FOR FINAL TERMINATION BY NOKLA 6) 24VDC MANUFACTURER SHALL PROVIDE ANO INSTALL CDS DATACOM ALARM CABLE PART ~C05610075 COILED AND READY FOR FINAL TERMINATION BY NOKIA 7) ALL CONDUCTORS SHALL BE BESIDNED AND INSTALLED IN ACCORDANCE W/NEC AND LOCAL CODES S) SUFFICIENT SLACK SHALL BE PROVIDED TO PERMIT NOKIA INSTALLER TO TERMINATE ALL CABLES 9) ALL CABLE ENDS AT THE NOKIA ERS SHALL BE IDENTIFIED AND TAPED o, / ¢7/PA NEL SCHEDULE GSMlgO0 Txl/Rx l~Tx2~Rx2 GSM850 Txl Rxl/Tx2/Rx2 800 10121 SITE NUMBER: U-1017 RF SYSTEM SCHEDULE I J- H 0,. mU N/A ~mREIN (2)-1/2" N/A 15-~ ~ N/A N/A OD-B60/1920/GPS -- GROUND ~ 0 0 l~ (TOP OF TOWER) (BOSOM OF TOWER) BILL OF ~R~S NOTES: + - + - --GROUND ~ J I  ~ ~ ' 5 1/2' BO~Oa JUmP[RS W/~[-~ CON. (giN) CO~aSCOP[ S~500 2~ CODE ANTENNA $CHE~ATlC ~ e n g n , EAST MARION TENNA SCHEMATIC - ~.~ .... ~ ~ ~ ~ ~ ~ND--RP SCHEDULE SITE NUMBER: U-1017 RF SYSTEM SCHEDULE LMU N/A KA~-IREIN (2)--1/2" N/A 15-FT ~PS N/A N/A OD-B60/1 g20/GPS 900 850 TE21 AN1ENNA ~MR240 (T~ e) (o~o~*~ w,,~o) RACK LMR240 (~tP 6) ~ 24V DC ,~ (-) infin!gy engineeri g 150-034 EAST MARION SITE NO. L1-1017 9245 MAIN ROAD EAST MARION, NY 11939 cNE.w 'ngwU,r TO (2) ~/4' FL[X CONDUIT TO ~[R eTS) SCHEMATIC & MATERIALS I o 0 0 WHT/BLU '-I BLU~HT WNT/ORG W~/aRN W~/SLT ~ 10 ~ ~~NA BEN/RED RED/SLT BLK/BLU ~=~ 21 ~m RED/~ ~ NOTCH SL~/~ 3 ~ ~ ~ ~ ~ = ~aa Pow~ F~L (~ CC) ~ 7 ORG/B~ ~ ~ = ~ 24 ~ ~ (~ ~6, ~ ~ 16) ~ ~ ~N/RED ~ ~ ~RMI~ ~/~. BLK/GRN z ~=,.,/=,,~. -~ =,.._z. 26 "-~-= I RECT 24V - MINOR (PRE-WIRED IN 24V) BEN/RED LABEL m PORT MARKED 'UNPROTECTED' TO TELCO ~ NiU J6 AWG STRANDED INSULATED GROUND WIRE BONDED TO MGB OR GROUNDED ENCLOSURE I~ DIN RAIL, OR EQUAL, AND SECURELY MOUNT TO TELCO g .GE suP 66 BLOCK ALARM ASSIGNMENTS ~N~UJ~-~,~CGESS i n fi n i 'c~ EAST MARION NE ~ro~ax.,,m~='~ MISCELLANEOUS gular N_ARMS ROUTED TO CINGULAR 66-BLOCK ALARM BLOCK INSIDE THE CINGULAR TELCO ENCLOSURE USING BELDEN t9565 6-PR t24UTP .u.c -ooL ~ . 0 0 . .0x~.,N 0 0 0~:~ 22 SRN~ ~ ~ ~ 8 N/A 3 ~M ~S Wl~ MNR2 ~ ~ 6 MJb1 ~M ~' ~ o 26 x m 28 SLT/RED ~= 20 =~ ~ N/A '"'"'"'"'" MJ~ ~ BLU/B~ ~= ~ ~ C~SIS L CRITA1 ~ ~ (~,14.~1D ~) 30 ORG/B~ 3~= 24 =~] J N/A ~ RF ~P FAULT_MCPA 8~ (CELT) ~ ~ ==~3 ~R A ~ GRN 19~ 1-~PA FNL ~ L _ ] (REMO~ JUMPE~ ~ REQUIRED ~ ~ ~ ~ ~ ] MCPA MAIN A~EM BLOCK ~. ~.sT~ a~lN~ cups (S~ON-~-~-2S ~ 150-034 WIRELESS FROM MCPA CHASSIS SIGNAL WIRE COLOR ALARM MINOR ALM BLK MC. PA FAN FAIL MINOR ETN RED f/JR A ALM GRN 1900 1--MCPA FAIL }/,JR A RTN BLUE CRT A ~ WHT/BLK 1900 2--MCPAs FAll