Loading...
HomeMy WebLinkAbout34373-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPA=RTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPkNCY NO: Z-34166 Rte: 01/15/10 THIS u~KTIFIES that the building TOWER Location of Pro~rty: 9245 MAIN RD EAST MARION (HOUSE NO.) (STREET) (HAMLET) County Tax Map NO. 473889 Section 31 Block 3 I~t 11.31 subdivision FiledMap NO. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated JANIJARY 5, 2009 pursuant to which Building Permit No. 34373-Z dated JD/gU~=Ry 5, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is EMERGENCY TELECOMMUNICATIONS TOWER AS APPLIED FOR PER ZBA #5972 DATED 3/8/07. · ~ne certificate is issued to EAST MARION FIRE DISTRICT (OWNER) of the aforesaid building. Bo~I~( ~DEP~TOF}~THAP~O%r~J~ N/A R~C'~RIC3%L C~KTIFICATH NO. 08-0149 04/27/09 PLD)~EBS u~KTIFICATION DA'r~u3 N/A Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. Ifa Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certi~cate ~f ~ccupancy - New dwel~ing $25.~~~ Additi~ns t~ dwel~ing $25.~~~ A~terati~ns t~ dwel~ing $25.~~~ Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Y Location of Property: q~.~' House No. Old or Pre-existing Building: (check one) Street Owner or Owners of Property: ~7'1~,3~ [~IOA/ ~'7L~7 ~[ ,'f'/tb I~'-' o~''' Suffolk County Tax Map No 1000, Section ~ / Block ~..,~ Subdivision Permit No.3 $/375 Health Dept. Approval: Dar e o f Permit. ]/~'~/~ / / Filed Map. Applicant: Underwriters Approval: Hamlet Lot Ii'SI Lot: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature Electrical Inspectors, Inc. 308 Fast Meadow Aveau¢ East Meadow, NY 11554 Office: ($16) 794-0400 C631 )396-7~.74 Fax: (516) 794-5854 Wcb~ite: www.elec Ulcalin spec tots.corn Email: in fo~elect ricalin~pectors.com Mail To: Charles M. Dwyer, Inc. Charles Dwyer 1457 Montauk Highway East Patehogue, NY 11772 License: 4278ME Certi/IcateNumber: 08-0149 Mtml¢ipality: Southold, Town Of Inspector: 125 l~sue Date: 4/27/2009 Propct~y Add~'c~s: AT&T Wkelass 9245 Main Road East Marion, NY 11939 ELECTRICAL APPR 0 VAL CER TIFICA TE AREAS LISTED BELOW ARE APPROVED BY INSPECTION AND FOUND TO BE IN COMPLIANCE WITH TI-13E NATIONAL ELECTRIC CODE NO visual defects were found for the oleclrical inspection provided. No obviouz uasatlsfaotory conditions were found in thc areas heroin below only. ... Comn~et~clal lnspe.~lon ~OOAmp $inglo Phase ~. ~gr~t~d ~ervlce, 200dm~ Single pltase DisConnect, Duplicate Original/MH Richard M. Bivo~ Philip F. Goehring Chic f Electrical Inspector Not valid uulcss signed blt authorized Eli Agent FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34373 Z Date JANUARY 5, 2009 Permission is hereby granted to: for : EAST MARION FIRE DISTRICT PO BOX 131 EAST MARION,NY 11939 CONSTRUCTION OF AN EMERGENCY COMMUNICATIONS TOWER PER ZBA #5972 AS APPLIED FOR. THIS PERMIT REPLACES BP 32920. at premises located at 9245 County Tax Map No. 473889 Section 031 pursuant to application dated JANUARY Building Inspector to expire on JULY MAIN RD EAST MARION Block 0003 Lot No. 011.031 5, 2009 and approved by the 5, 2010. Fee $ 250.00 Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUII/DING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. ~920 Z Date APRIL 19, 2007 Permission is hereby granted to: MARION FIRE DISTRICT EAST PO BOX 131 EAST MARION,NY 11939 for : CONSTRUCTION OF A/q EMERGENCY COMMUNICATIONS TOWER PER ZBA #5972 AS APPLIED FOR at pre~n~ses located at 9245 County Tax Map No. 473889 Section 031 pursuant to application dated APRIL MAIN RD EAST MARION Block 0003 Lot No. 011.031 10, 2007 and approved by the Building Inspector to expire on OCTOBER 19, 2008. Fee $ 250.00 ,~~~~/~//~ ORIGINAL Rev. 5/8/02 inf ig)/ Albany Office I 1 Herbert Albany, NY 12203 December 10, 2009 Mr. Richard Chiappa Bechtel Telecommunications 95 Cheslaut Ridge Road Montvale NJ 07654 Construction Completion Compliance Letter - AT&T: East Marion Fire District Site no.: LI 1017 Dear Mr. Chiappa: Per your request, Infmigy Engineering is providing this letter to serve as a tower foundation Construction Completion Compliance LetXer for the above referenced site. Prior to issuance of this letter, a final inspection of the tower's foundation installation was completed and subsequent md-lined construction drawings, photos of construction process, and data from a post-construction caisson evaluation were submitted to lnfmigy Engineering. Per the information provided, lnfmigy Engineering confirms that the tower foundation installation was performed in general accordance with foundation design drawings prepared by Paul J. Ford and Company, Dated 01-03-08. Please do not hesitate to contact me at (518) 434-2288, if you have any questions or comments. Very truly yours, John Stevens, PE Infinigy Engineering PLLC BL06 ~,EPI TOWN OF SOUI~CLi? 2255 Sewell Mill Rd 11 Herbert Dr Madettal, GA 30062 I.at, ham, NY 12110 678-444-4463 518~690-0790 www.infinio¥.com Frr~l ,D ]~SPECTiON RElY)iRT I DATE FO~A~ON (1S~ FO~A~ON (2~) PL~G ~S~ATION PER N. Y. STATE E~RGY CODE , TOWN OF SOUTHOLD BUILDING ~EPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, b~efore applying? Board of Health 4 sets of Building Plans ..... i '~ ~ 7~ Planning Board approval FAX: (631) 765-9502 ~-, ~-}r~ A,-'~ Survey_ www. northfork.net/Southold/ PERMIT NO.~ Check ~' Septic Form ·// Examined 7//~ ,20~ Contact: ~ard G. Boyd, APPLICATION FOR BUILDING PE~IT INSTRUCTIONS Date ~'~o ~.~ 2.% ,2006 Esq. a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the inter/m, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. East Marion Fire District (Signature of applicant or name, if a corporation) P.O. Box 131 East Marion, New York 11939 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Owner Name of owner of premises East Marion Fire District (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Daniel H. Wood, Commissioner, EMFD Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 9245 Route 25 East Marion House Number Street County Tax Map No. 1000 Section Subdivision (Name) Hamlet 31 Block 3 Lot 11.31 Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and oc,~upancy of proposed construc6on: a. ~'x~stlng use and occupancy Publxc Safety - Flreh~0se b. Intended use and occupancy 3. Nature of work (check which applicable): New Building_ Repair Removal Demolition 4. Estimated Cost $130,000.00 5. If dwelling, number of dwelling units N/A If garage, number of cars N/A Public Safety - Firehouse and Public Safety Communications Tower Addition Alt~ation Other Wo~ Public Safety Communicatio Tower (Description) Fee (To be paid on filing this application) Number of dwelling units on each floor N/A 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. N/A 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Depth. Height Number of Stories Rear Dimensions of entire new construction: Front Height 12O' Number of Stories Size of lot: Front 293 ' Rear 249 ' 10. Date of Purchase 11/23/9 8 Name of Former Owner Rear Depth .Depth 342' Eugene Kessler, as Executor of the Estate of Herbert R. Mendel 11. Zone or use district in which premises are situated R40 and lib 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO 13. Will lot be re-graded? YES __ NO x Will excess fill be removed from premises? YES x East Marion 9425 Route 25 14. Names of Owner of premises Fire District Address East Marion, NYPhoneno. Name of Architect Address Phone No Name of Contractor Address Phone No. NO 477-0163 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES __NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES __ NO x * IF YES, D.E.C. PERMITS MAY BE REQUIRED. x 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF Suf fol~9 Daniel H. Wood being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)Heisthe Commissioner of the East Marion Fire District, Owner of Premises (Contractor, Agent, Corporate Officer, etc.) ~q&~,'~O~;~l*~[ and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before-me this ~,4 ~/'~ay of July 20 0 6 Notary Public EDWARD JOHN BOYD 5th Notary Public State of N~,'.~ York 02600376625 Suffolk County Commi-,,sion Ex~es April 30, 200 PLANNIN(~ BOARD MEMBERS Chair wtt,t.ta.M j. CREMERS KENNETH L. EDWARDS GEORGE D. SOLOMON JOSEPH L. TOWNSEND October 14, 2009 Net Com Development Att: Charles Eisenberg 30 Central Drive Farmingdale, NY 11735 PLANNING BOARD OFFICE TOWN OF SOUTHOLD Site plan for E. Marion FD Telecom - final inspection Located: 9245 Main Road, Mattituck SCTM# 1000-31-3-11.31 M~II/NG ADDRESS: P.O. Box 1179 Southold, NY 11971 O~'~'ICE LOCATION: Town Hall Annex 54375 State Route 25 (cot. Ma/n Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax~ 631 765-3136 Dear Mr; Eisenberg: As per your request, the Planning Staff conducted a site inspection of the above property on Thursday October 8, 2009 where the site work was determined to be in conformance with your approved site plan. Please note any future requested change to the site plan should include a copy of the approved stamped site plan noting the location of the requested change. If you have any questions regarding the above, contact me anytime. Thank you. Sinca~rel. y Kristy Win~Cer Senior Planner Cc: Planning Board Heather Lanza, Planning Director Michael Verity, Chief Building Inspector Jamie Richter, Town Engineer APPEALS BOARD MEMBERS Ruth D. Oliva Gerard P. Goehringer James Dinizio, Jr. Michael A. Simon Leslie Kanes Weisman http://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTItOLD Tel. (631) 765-1809 · Fax (631) 765-9064 Mailing Address: Southold Town Hall 53095 Main Road · P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex/First Floor, North Fork Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 FINDINGS, DELIBERATIONS AND DETERMINATION MEETING HELD: MARCH 8, 2007 ZB File No. 5972 -- EAST MARION FIRE DISTRICT Property Location: 9245 Main Road, East Marion Zone Districts (split): HB Hamlet Business; R-40 Low Density Residential CTM 31-3-11.31 containing 3.05 acres SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. In addition, the Town Planning Board has issued a Negative Declaration with a Determination of Non-Significance dated September 11, 2006. PROPERTY FACTS/DESCRIPTION: The applicant's property contains 3.05 acres owned by the East Marion Fire District and improved with two Fire House structures, as shown on the site plan prepared by Infinigy Engineering dated 8/17/06. BASIS OF APPLICATION: The applicant requests a Variance under Section 280-69 (100-162A3, A5), based on an application for a building permit and the Building Inspector's July 25, 2006 Notice of Disapproval, concerning construction of a proposed wireless communication/telecommunications monopole tower on property owned, leased or otherwise controlled by a special district approved by the commissioners of the special district. The proposed tower will exceed the code limitation - with a height greater than 10 feet above the average height of buildings within 300 feet of the facility, OR higher than 10 feet above the average tree canopy height in that radius measured from ground level if there are no buildings within 300 feet. Also, if there are no buildings within 300 feet of the proposed facility site, all telecommunication towers shall be surrounded by dense tree growth to screen views of the facility in all directions. SPECIAL DISTRICT: The applicant, East Marion Fire District (EMFD), is an established special district for emergency communications on at least 4.35 acres of land. The EMFD maintains its fire station communication transmissions to and from this site, and the wireless communications tower would be in a location that provides sufficient space and height to provide an installation of a 450 Hz antenna, north of the firehouse. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application has been referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning replied in its communications dated November 24, 2006 and January 22, Page 2 - March 8, 2007 ZB File No. 5972 - East Marion Fire Distdct ', CTMNo. 31-3-11.31 2007 stating that the application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. TOWN CODE CHAPTER 95 (268) LWRP CONSISTENCY: This application has also been referred as required under Chapter 95 (268) of the Town Code, and LWRP Coordinator Mark Terry has issued a determination dated Apdl 26, 2006, received October 23, 2006, stating that this application is consistent with the Policy Standards. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on November 30, 2006 and January 25, 2007, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicant, East Marion Fire District, wishes to construct a telecommunications monopole tower to support public safety communications antennas, at a maximum height of 120 feet. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of alternative relief will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The site where the monopole antenna will be constructed is presently open space lying just north of the two structures that serve the community of East Marion as a firehouse. The site has been used for many years for the pbrposes of storing and maintaining fire fighting and associated support equipment such as fire trucks, hoses, ladders and radio equipment to communicate during actual fires. The addition of this monopole antenna will improve the reliability of the radio equipment currently in use. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The East Marion Fire District only owns one piece of real property, and it is upon this property that the monopole antenna will be erected. Security, electrical supply, and proximity to the source of dispatch demand that the principal antenna be located as close to the firehouse as possible. 3. The alternative relief granted herein is substantial. The variance sought by the applicant and the alternative relief granted herein, will increase the antenna height at least 90% over the code maximum. (The code requirement is a maximum of 60 feet in height.) Although a monopole antenna of this size will create some visual change in the area, this change must be balanced against the necessity of improving emergency communications for the community. 4. Granting of the alternative relief for a height variance will not have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district. The monopole antenna is designed to withstand the highest anticipated wind velocities and constructed in accordance to current engineering standards. All equipment required for powering and maintenance of the antenna will be located within a securely fenced area surrounding the base of the monopole, which Page 3 - March 8, 2007 ZB File No. 5972 - East Marion Fire District CTM No. 31-3-11.31 will be screened by native plantings. All radio transmissions will be regulated by appropriate agencies. 5. The alleged difficulty has not been self-created. It is necessary to update the means of communications as technology advances with time. The current technology requires a certain tower height in order to guarantee adequate coverage of the fire district. 6. The proposed height is not the minimum that is necessary to preserve and protect the character of the neighborhood and the health, safety, and welfare of the community. The testimony presented was not sufficient to persuade that the antenna height of 120 feet is necessary to provide the desired coverage at the fire district. The Board considers the substantial alternative relief granted to be sufficient to satisfy the applicant's needs and to meet reasonable concems of public safety. 7. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a telecommunications tower facility, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Simon, seconded by Member Oliva, and duly carried, to DENY the variance as applied for, and in the ALTERNATIVE, to GRANT a variance in the location shown on the 6-17-06 Infinigy Site Diagram (setbacks 105 feet from the north lot line, 196+/- feet set back from the westerly lot line), at a maximum antenna height of 110 feet, subject to the following conditions: 1) The covering of the monopole shall be painted a color that will make it blend into the area. The board suggests a neutral color such as gray or gray- blue. 2) No flag shall be placed upon the monopole antenna. 3) The monopole shall not be lighted except as required by law. That these ZBA conditions be written into the Building Inspector's Certificate of Occupancy, when issued. Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board: Ayes: Members, Oliva, Goehringeg, Simon, and Weisman. Nay: Chairman Dinizio (in favor of requested 120 ft. hei~ht~. This Res~uti,~n was duly a~opted (4-1). Ja,~a'-e'~'Dinizio Jr.~-C~airr~n-" /" 3/9/2007 Af~proved for Filing \, 5 S 65'40'00" 19.58' ~' o~ .,.. A,,.OVEO AS nRE .S,ECnO" UIJI~ITERS CERTIFICATE DATE~/PI!~ B.P., ~~ - REQUIRED BEFORE ~o°~ ~ '~ OPENING NO'IN BUILDING DEPA~MENT AT 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: EAST MARION FIRE DISTRICT ~. ~OUNO*T,ON- ~0 ~0" ,OU,EO CONC"~ ocCUPANCY OR ~.,OU~H-FR*M,N~ ~ PLUM~,N~ USE IS UN~WFUk SITE NAME: EAST MARION 4. FINAL' CONSTRUCTION MUST WITHOUT CERTIFICATE BE COMPLETE FOR C.O. AL~ CONST,UCT'O" SHA~ UE~ TH" OF OCCUPANCY REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. D~WING INDEX R~ VICINI~ MAP ~ PROJECT INFORMATION TO1 TITLE SHE~ A~ scoPE oF ~K: oFAN ~Nc~UNMANNEDcoMP~ND~LEC~MUNICA~ONAND 110' UNIP~.¢AC~LI~ IN~UDING ~E INSTA~ON C01 SITE P~N A ~ ADDRESS: 9245 MNN R~ C02 D~AILED SITE P~N AND DETAILS A ~T ~ON. CO~ G~DING, EROSION & SEDIMENT CONSOL NO~S A ~NO O~ER/APPLICANT: EAST MA~ RRE DISmlCT P.O. BOX 151 C03 EL~ATION Vl~S A EAST MARI~, NY 11939 TAX ID NUMBER: 31-5-11.51 C~ CONSTRUCTION D~AILS A LA~O[ (NAD 83): 4~' 07' ~5 CONSTRUCTION D~AI~ A ~' ~ ~~ L~DE (NAD 83): 72' 20' 29.2' C~ ~NDSCAPE P~N A ~ ~ ~ ~c~: TO~ ~ s~m~ . E01 ~ERIOR GROUNDING P~N A CURE[NT U~: ,,[ STA~ ~ / =~.~ ~ ,- ~C~MUNICA~S FACILI~ ~ ' CUR~E,T zo,m,c: SPUT-Z~[D HB ~PHONE COMPANY: ~RIZON COMPLY WITH ALL CODES OF m NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF. SO,HOLD ~ :~ c~~~ ~ "~,J', ~ SITE QUALIFICATION PARTICIPANTS A/E dOHN S~NS INRNIGY ENGINEERING (518) 454-2288 ~ ~~ RF BILL SCHEIBEL BECH~L (651) 655-6650 i ? ~. [ ~, j g Y "ST MARION ~:~ T, TLE SHEET "~* "' ~ ~ EAST MARION FIRE DISTRICT CHERYL L. BONDARCHUK USE: RESIDENTIAL - 1 FAMILY RESIDENCE ZONED: R-40 % ANTHONY LEKAKIS USE: RESIDENTIAL VACNAT LAND ZONED: R-40 LOT 1 GRAY/BLUE -EXISTING CONC. SL~ WMITE SWAN ~ USE: 1 FAMILY  RESIDENCE N/F ZONED: R-40 EASTERNR.E,BREEZES USE: 1 FAMILY RESIDENCE ZONED: R-40 ~_~. SITE pLAN tS NOT TO SCALE. ACTUAL RELD CONDmON OF EXISTING BUILDING STRUCTURE IS FROM PROPEEq'( UNES. NOT WHAT IS DEPICTED ON THIS PLAN, COMPOUND AND TOWER SETBACK DIMENSIONS ARE TRUE SYLVIA M. DALE¥ USE: 1 FAMILY RESIDENCE ZONED: R-40 SYMBOLS AND MATERIALS DETAIL REFERENCE SEC~ONS AND DETAILS CONCRETE EARTH GRAVEL/STONE i n f i n i c-..,a/Y. engineering 150 - 034- NOTE: METES AND BOUNDS ARE TAKEN FROM A SURVEY PERFORMED BY PECONIC SURVEYORS PC, UCENSED LAND SURVEYOR. S 65'40'00' W N/F E.M. WAR MEMORIAL ASSOC, USE: RESIDENCE ZONED: HB SITE PLAN SITE LEGEND PROPER~ LINE FENCE LINE ELECTRIC SERVICE / EXISTING ? UTILrPf POLE TELEPHONE SERVICE PROPOSED CONTOUR 50 EXISTING CONTOUR lEAST MARION FIRE DISTRICTt j;_ I 7 + EAST MARION 9245 IvlAIN ROAD I OESIGNED: GENERAL NOTES: 1. SITE PLAN INFORMATION WAS WAS BASED ON VARIOUS SOURCES OF INFORMATION INCLUDING FIELD NOTES & MEASUREMENTS PERFORMEO BY INFINIGY ENGINEERING, PLLC OF NY. 2. THIS PROPOSAL IS FOR AR UNMANNED TELECOMMUNICATIONS FACILITY CONSiSTING OF FENCED COMPOUND WITH UTILFFY RACK AND UNIPOLE. ,3. THE PROPOSED EAClLllY W~LL BE UNMANNED AND DOES NOT REQUIRE WATER OR SEa/ER SERVICE. 4. THE PROPOSED FAClLll'K IS UNMANNED, AND IS NOT INTENDED FOR HUMAN HABITATION AND THUS DOES NOT REQUIRE HANDICAP ACCESS. 5. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION TIMES PER MONTH. 6. NO STROBIC UONTING IS INCLUDED IN THIS PROPOSAL. 7. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM TH~S PROPOSAL 8. OUTOOOR STORAGE AND SOUD WASTE CONTAINERS ARE NOT PROPOSED. 9. EXTERIOR SIGNS ARE NOT PROPOSED. 10. NO NE~V ACCESS ROAD WILL BE REQUIRED UNDER THIS APPLICATION. 11. TOTAL AREA OF DISTURBANCE UNDER THIS PROPOSAL: 830 SF± 12. THE INCREASE IN STORM WATER RUNOFF DUE TO THE INCREASE IN IMPE~OUS AREA IS INSIGNIFICANT. EX~STING DI~JNAGE PATTERNS WILL NOT BE ALTERED. THEREFORE, DRAINAGE STRUCTURES ARE NOT PROPOSED. ALL CONSTRUCTION FOR SITE IMPROVEMENTS SHALL CONFORM TO APPLICABLE SPECIFICATIONS, STANDARDS, AND REQUIREMENTS OF THE GOVERNMENTAL OR UTILITY AUTHORITIES HAVING JURISDICTION. 14. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC. AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK. SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILUNG AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFET¢ TRAININD FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT UMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING & EXCAVATION 15. ALL SITE WORK SHALL BE AS INOICATED ON THE DRAWING AND STIPULATED IN THE PROJECT SPECIFICATIONS. 16. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEC~J_LY. 17. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE RADIO EQUIPMENT AND ¢LAGPOLE AREAS. 18. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIEORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 19. ALL EXISTING ~NACTIVE SEWER, WATER, GAB, ELECTRIC AND OTHER UTIUTIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK. SUBJECT TO THE APPROVAL OF ENGINEERING. 20. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE PROPOSED IMPROVEMENTS SHALL BE RESTORED AS REQUIRED. 21. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SED{MENT CONTROL. 22. ALL SITE WORK SHALL BE COORDINATED WITH THE PROPERTY OWNER AS REQUIRED. 23. CONTRACTOR SHALL CONTACT DIG ALERT: 800-962-7962 TO LOCATE' TO CONSTRDCT,ON. .'?.', PROPOSED 16'x22' LEASE AREA -- 'PROPOSED 110' UNIPOLE IN NEUTRN. GRAY/BLUE COLOR --PROPOSED 290 SQ. FT. FENCED AREA (6' BLACK VINYL COATED CHNN UNK FENCE) DETAILED SITE PLAN GEN[RAL SITE NOTES: 1. THE 5U~GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPUCATION. 2. ALL EXISTING ACTIVE SE~/ER, WATER, GAS, ELECTRIC, AND OTHER U~UT1ES WHERE E]flCOUNT-r-RED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY I~IE CO~TOR WHEN EXCAVATING OR PIER DRILUNG AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFELY TRAINING FOR THE WORKING ENGINEER. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCON11NUED AT POIN~TS WHICH WILL NOT INTERFERE WITI4 THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF AR ENGINEER. 4. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM ALL EQUIPMENT AND TOWER AREAS. 5. GARBAGE, STUMPS, DEBRIS. STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER.. 6. THE AREAS OF THE OWNERS PROPER~ DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING OR DRNEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, FERTIUZED, AND SEEDEO. infini!j engineering 150 - 034 EAST MARION 9245 MAIN ROAD EAST MARION, NY 11939 lEAST MARION FIRE DISTRICT A 21-07 ,~UNISTRUT PIPE/CONDUIT CLAMp Pl119 OR P2558-B§ (GALV.) (1YPICAL) BoLTFOLLOWToRQuEMANUF' RECOMMENDATIONS FOR PIPE (GALV) UNiSTRUT P1001 (GALV) UNISTRUT CONCRETE OR SAKRETE PIER. E~L:EC~/TELCO SUPPORT RACK ~ DETAILED SITE PLAN AND DETAILS GRADING & EXCAVATING NOTES: 1. ALL EXCAVATIONS ON WHICH CONCRETE IS TO BE pLACED SHALL BE SUBSTANTIALLY HORIZONTAL ON UNDISTURBED AND UNFROZEN SOIL AND BE FREE FROM LOOSE MATERIAL AND EXCESS GROUNDWATER. DEWATERING FOR EXCESS GROUNDWATER SHALL BE PROVIDED IF REQUIRED. 2. CONCRETE FOUNDATIONS SHALL NOT BE PLACED ON ORGANIC MATERIAL. IF SOUND SOIL IS NOT REACHED AT THE DESIGNATED EXCAVATION DEPTH, THE UNSATISFACTORY SOIL SHALL BE EXCAVATED TO ITS FULL DEPTH AND EITHER BE REPLACED WITH MECHANICALLY COMPACTED GRANULAR MAI[RIAL OR THE EXCAVATION BE FILLED WITH CONCRETE OF THE SAME QUAMTY SPECIFIED FOR THE FOUNDATION. 3. ANY EXCAVATION OVER THE REQUIRED DEPTH SHALL BE FILLED WITH EITHER MEChaNICALLY COMPACTED GRANULAR MATERIAL OR CONCRETE OF I~IE SAME QUALRY SPECIFIED FOR THE FOUNDATION. CRUSHED STONE MAY BE USED TO STABILIZE THE BOTTOM OF THE EXCAVATION. STONE, IF USED, SHALL NOT BE USED AS COMPIUNG CONCRE-IE THICKNESS. 4. AFTER COMPLETION OF THE FOUNDATION AND OTHER CONSTRUCTION BELOW GRADE, AND BEFORE BACKFILMNG, ALL EXCAVATIONS SHALL BE CLEAN OF UNSUITABLE MATERIAL SUCH AS VEGETATION, TRASH, DEBRIS, AND SO FORTH. 5. -USE APPROVED MATERIALS CONSISTING OF EARTH, LOAM, SANDY CLAY, S~ND -BE FREE FROM CLODS OR STONES OVER 2-1/2' MAXIMUM DIMENSIONS -BE PLACED IN 6" LAYERS AND COMPACTED TO 95% STANDARD PROCTOR EXCEPT IN GR~SSED/LANOSCAPED AREAS. WHERE 90~[ STANDARD PROCTOR REMOVE ALL VEGETATION, TOPSOIL, DEBRIS, WET AND UNSATISFACTORY SOIL MATERIALS, OBSTRUCTIONS, AND DELETERIOUS MATERIALS FROM GROUND SURFACE PRIOR TO PLACING FILLS. PLOW, STRIP, OR BREAK UP SLOPED SURFACES STEEPEN THAN THAN I VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING SURFACE. WHEN SUBGRADE OR EXISTING GROUND SURFACE TO RECEIVE FILL HAS A DENSI'Pf LESS THAN THAT REQUIRED FOR FIL~ BREAK UP GROUND SURFACE TO DEPTH REQUIRED, PULVERIZE, MOISTURE-CONDITION OR AERATE SOIL AND RECOMPACT TO REQUIRED DENSISY. PROTECT EXISTING GRAVEL SURFACING AND SUBGRADE IN AREAS WHENE EQUIPMENT LOADS WILL OPERATE. USE pLANKING OR OTHER SUITABLE MATERIALS DESIGNED TO SPREAD EQUIPMENT LOADS. REPAIR DAMAGE TO EXISTING GRAVEL SURFACING OR SUBGRADE WHERE SUCH DAMAGE IS DUE TO THE CONTRACTOB'S OPERATIONS. DAMAGED GRAVEL SURFACING SHALL BE RESTORED TO MATCH THE ADJACENT UNDAMAGED GRAVEL SURFACING AND SHALL BE OF THE SAME THICKNESS. REPLACE EXISTING GRAVEL SURFACING ON AREAS FROM WHICH GRAVEL SURFACING IS REMOVED DURING CONSTRUCTION OPERATIONS. GRAVEL SURFACING SHALL BE REPLACED TO MATCH EXISTING ADJACENT GRAVEL SURFACING AND SHALL BE OF THE SAME THICKNESS. SURFACES OF GRAVEL SURFACING SHALL BE FREE FROM CORRUGATIONS AND WAVES. EXISTING GRAVEL SURFACING MAY BE EXCAVATED SEPARATELY AND REUSED IF INJURIOUS AMOUNTS OF EARTH, ORGANIC MATrER, OR OTHER DELETERIOUS MATERIALS ARE REMOVED PRIOR TO REUSE. FURNISH ALL ADDITIONAL GRAVEL RESURFACING MATERIAL AS REQUIRED. BEFORE GRAVEL SURFACING IS REPLACED, SUBGRADE SHALL BE GRADED TO CONFORM TO REQUIRED SUBGRADE ELEVATIONS, AND LOOSE OR DISTURBED MATERIALS SHALL BE THOROUGHLY COMPACTED. DEPRESSIONS IN THE SUBGRADE SHALL BE FIllEr) AND COMPACTED WITH APPROVED SELECTED MATERIAL. GRAVEL SURFACING MATERIAL MAY BE USED FOR FILLING DEPRESSIONS IN THE SUBGRADE. SUBJECT TO ENGINEER'S APPROVAL DAMAGE TO EXISTING STRUCTURES AND UTILITIES RESULTING FROM CONTRACTOR'S NEGUGENCE SHALL BE REPNRED/REPLACED TO OWNER'S SATISFACTION AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL COORDINATE THE CONSTRUCTION SCHEDULE WITH PROPERI'f OWNER SO AS TO AVOID INTERRUPTIONS TO PROPER~f OWNER'S OPERATIONS. ENSURE POSITh/E DRAINAGE DURING AND AFTER COMPLETION OF CONSTRUCTION. ALL CUT AND FILL SLOPES SHALL BE MAXIMUM 2 HORIZONTAL TO 1 VERTICAL. CONTRACTOR SHALL BE RESPONSIBLE FOR MONITORING SITE VEHICLE TRAFRC AS TO NOT ALLOW VEHICLES LEAVING THE SITE TO TRACK MUD ONTO PUBUC STREETS. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING PUBUC STREETS DUE TO MUDDY VEHICLES LEAVING THE SITE. i n f i n i engineering 150-034 EAST MARION 9245 MAIN ROAD GENERAL EROSION & SEDIMENT CONTROL NOTES: 1. THE SOIL ENOSION AND SEDIMENT CONTROL MEASURES AND DETAILS AS SHOWN HERIN AND STIPULATED WITHIN STATE STANDARDS SHALL BE FOLLOWED AND INSTALLED IN A MANNER SO AS TO MINIMIZE SEDIMENT LEAVING THE SITE* 2. PRIOR TO COMMENCING LAND DISTURBANCE ACTMSY. THE UMITS OF LAND DISTURBANCE SHALL BE CLEARLY AND ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR OTHER APPROPRIATE MEANS. S. EROSION CONTROL DEVICES SHALL BE INSTALLED BEFORE GROUNO DISTURBANCE OCCURS. THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM SHOWN ON THE APPROVED PLANS IF DRNNAGE PAl I~I<NS DURING CONSTRUCTION ARE DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PAT[ERNS. IT IS THE CONSRACTOR'S RESPONSIBIMS~ TO ACCOMPLISH EROSION CONTROL FOR ALL DRAINAGE PA~TERNS CREATED AT VARIOUS STAGES DURING CONSTRUCTION. ANY DIFEICUL~Y IN CONTROLLING EROSION DURING ANY PHASE OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 4. THE LOCATION OF SOME OF THE ENOSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE DIFFERENT FROM THE FINAL PROPOSED DRNNAGE PATrERNS. ANY DIFFICUL]Y IN CONTROLMNG EROSION DURING ANY PHASE OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 5. CONTRACTOR SHALL MAINTAIN ALL ENOSION CONTROL MEASURES UNTIL PERMANENT VEGETATION HAS BEEN ESTABLISHED. CONTRACTOR SHALL CLEAN OUT ALL SEDIMENT PONDS WHEN REQUIRED BY THE ENGINEER OR THE LOCAL JURISDICTION INSPECTOR. CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES AT THE END OF EACH WORKING DAY TO ENSURE MEASURES ARE FUNCTIONING PROPERLY. 6, THE CONTRACTOR SHALL REMOVE ACCUMULATED SILT WHEN THE SILT IS WITHIN 12' OF THE TOP OF THE SILT FENCE. 7. FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL ENOSION CONTROL MEASURES WILL RESULT IN ALL CONSTRUCTION BEING STOPPED ON THE JOB SITE UNq]L SUCH MEASURES ARE CORRECTED. 8. SILT BARRIERS TO BE PLACED AT DOWNSTREAM TOE OF ALL CIJ~ AND FILL SLOPES. 9. ALL CUT AND FILL SLOPES MUST BE SURFACED ROUGHENED AND VEGETATED WITHIN SEVEN (7) DAYS OF THEIR CONSTRUCTION. 10. CONTRACTOR SHALL REMOVE ALL ENOSION & SEDIMENT CONTROL MEASURES AFTER COMPLE'rioN OF CONSSRUCTION AND ESTABLISHMENT OF PERMANENT GROUND COVER. 11. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF ENOSION CONTROL MEASURES AND PRACTICES PRIOR TO, OR CONCURRENT WITH, L~ND-DISTURBING ACff~qTIES. EAST MARION FIRE DISTRICT A 21-07 VEGETATIVE SCHEDULE SPECIES RATE/1000 S.F. DATE APPUCATION N, ~/ACRE TOP DRESSING 1st 2nd NOTE: FERTILIZER MIX IP~ 0,. #/ACREI K~O. ~/ACRE IN. 60- 90 1201--:0100 1201-180:0 50 SEEDBED PREPARATION WILL BE REQUIRED, THE FERTIUZER, SEED AND WOOD CELLULOSE FIBEN BE COMBINED TO FORM A HOMOGENEOUS MIXTURE, AND SPREAD UNIFORMLY OVER THE AREA WILL BE APPUED WITH BLOWER-~YPE MULCH SPREADING EQUIPMENT WITHIN 24 HOURS AFTER PERCENT OF THE GROUND SURFACE EXPOSED, GRADE, SHAPE AND SMOOTH WHENE NEEDED TO PROVIDE FOR SAFE EQUIPMENT OPERATION AT BE SPREAD UNIFORMLY OVER THE AREA IMMEDIATELY BEFORE SEEDBED PREPARATION, A ON SITE. THE SEEDBED MUST BE WELL PULVERIZED, SMOOTHED AND FIRMED. SEEDING WILL SEEDER. SEED WILL BE DISTRIBLqE:D UNIFORMLY OVER A FRESHLY PREPARED SEEDBED AND UNIFORMLY OVER THE AREA, LEADING ABOUT 25 PERCENT OF THE GROUND SURFACE EXPOSED. IMMEDIATELY AFTER IT IS SPREAD. A DISK HARROW WEH THE DISK SET STRAIGHT OR A SPECIAL GRADING, EROSION & SEDIMENT CONTROL NOTES 24897 ~NYCENY 017 C02A i] INF'INIGY ENGINEERING HAS NOT EVALUATED THE1 EXISTING TOWER FOR THIS SITE. IT IS THE CARRIER'S RESPONSIBIIJ~Y TO INVESTIGATE ANY LOADING CONCERNS WHEN ADDING ADDITIONAL EQUIPMENT TO THE TOWER. (TO BE SUPPUED .~D L~'TALLED BY OTHERS) PROPOSED 6' BLACK GRADE LEVEL = O' (AOL) (BY O~HERS) PROPOSED 6' BLACK VINYL CHAIN UNK GRADE LEVEL = 32' (AMSL) GRADE LEVEL ~ O' (AGL) SOUTH ELEVATION EAST ELEVATION infini(.j en~ineerino 1 §0-03~- EAST MARION 9245 MAIN ROAD EAST MARION, NY 11939 lEAST MARION FIRE DISTRICT (~Y OTHERS) TELEWAVE EXPOSED DIPOLE 450D6-9 10 FEET 30 FEET ANDREW D3205 10 FEET 30 FEET FIBER GLASS 5db ANDREW D3633 5 FEET TOP OF POLE FIBER G!.~,SS 5db RFS 201 8 FEET 30 FEL-~ FIBER GLASS 5db ANDREW ASP680 11.7 FEET 50 FEET ANTENNA MODEL DETAIL ELEVATION VIEWS ~o3 t I sn~ f 24897 ~NYCENYI017 I 4'-0" GATE OPENING COATED CHAIN MNK - UNE POST (TI'P,) / TfPE LATCH WITH PROVISION FOR RAIL PAIR INDUSTRIAL / PADLOCK (PAGE-WILSON TfPE 75 ~--TOP RNL (TYP) - BLACK VINYL ~: 5/8"e ]RUSS ROD WITH I ~H, BOTi'OM TENSION WIRE 2" CON ELECTRICAL COPPER BRND [~ ~ ' [- '- ~= SPACING O'YP.) I I r6. FORENO, 1'-2" CORNER, & GATE POSTS -~-- F[NC£ NOIES: in ,f.i n. j ~1 y F_*S~'~A.,O. CONSTRUCTION ~"o."~ o.,e.~e~ .,~ Ce/ EAST MARION FIRE DISTRICT DETAILS i 150-034 MIN FENCE- WHERE REQUIRED ~YPE C SILT FABRIC ON UPSTREAM SIDE OF FENCE DIRECTION OF FLOW 1. DIG TRENCH 2. LAy IN FABRIC TO BOTTOM OF TRENCH 3. BACKFILL TRENCH. COVERING FABRIC SILT FENCE DETAIL CONSTRUCTION NOTES FOR FABRICATED SILT FENCE WOVEN WIRE FENCE TO BE FAS~NED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION. WHEN 1WO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVER- L~PPED BY SIX INCHES AND FOLDED. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN 'BULDGES" DEVELOP IN THE SILT FENCE. ALL SILT FENCE MATERIALS MUST BE USTED ON THE CURRENT STATES. D.O.T. QUALIFIED PRODUCTS MST ~36. POSTS: STEEL EITHER T OR U TYPE. FENCE: WOVEN WIRE, 14 GA. 6" MAX. MESH OPENING. AS DIRECTED BY BANKS CO, FILTER CLOTH: FILTER X, MIRAFI lOOX' STABIUNKA T140N OR APPROVED EQUAL. PREFABRICATED UNIT: GEOFAB. ENVIROFENCE OR APPROVED EQUAL. EAST MARION 9245 MAIN ROAD EAST MARION, NY 11939 EAST MARION FIRE DISTRICT A 21-07 1 -DP, N)E TO DRNN AWAY FROM TOWER YN~D SECTION THROUGH COMPOUND CONSTRUCTION DETAILS C ~ TO RN~ TREE STAKING AND GUYING 1. ~DS S~ FOR~ IN "AMERI~ ~D~D FOR NURSE~ ~K', ~ EDEN, REPRESE~ GUIDEUNE SPECI~ONS ONLY ~D S~ CONS~ MINIMUM QU~ REQUIR~E~ F~ P~ ~R~ 2. ~ P~ ~E SU~ECT TO ~E ~R~ OF ~E ENGINE~'S REPRESE~A~ BEFORE, DURING, ~D ~R INfO'ON. 5. PRI~ TO CON~U~ION, ~E CO--TOE S~ BE RES~NSIB~ FOR L~NG UN~RG~ND ~1~ ~D S~ A~ID ~GE TO ~ ~ES DU~NG C~RSE OF ~E W~K. ~E CO~OR IS RES~NSIB~ FOR REPNRING ~ ~E TO ~, ~UC~RES, ~ ~PU~C~, ~C. ~ICH ~CU~ ~ A R~LT OF ~E ~DS~E CONiStON. 6. ~ TRE~ WU~ BE ~ ~NKED, ~ H~ED ~D ME~ ~ RE~IR~E~ SPECIR~. ~. ~ m~ vu~ ~[ O~D OR ~A~D ~ SH~.. ~NSCAPING P~N 8. ~ P~ ~D P~NG ~ MU~ BE ~MP~LY MULCHED ~ SPEClR~. 9. ~E ENGINe'S R~RES~A~ ~ ~PR~ ~E ~ L~ON OF ~ PR~R TO IN~. m 10. ~E CO~ ~ R~NSIB~ FOR ~I~NG ~ QU~ES SH~ ON ~ESE ~S 11. ~E ~TOR IS R~PONSIB~ FOR ~Y ~NNI~ ~ P~NG (INCLUDI~, B~ NOT UU~ TO: WARRING, ~NO, MULCHING, ~U~, ~C.) OF ~NO U~IL ~E WORK ~ A~E~D IN TOT~ ~ ~E ~GIN~'S R~RESE~A~. ~T~ 12. ~ B~NG DUO AT ~E NU~E~ ~URC[ ~ ~S IN ~ S~ BE ~LI~D FOR ~0 (2) ~EKS UND~ A BI~ ~EM PRIOR TO wo~) ~ .[ ~.~ .~ ~. ~ ~ ~ .~ w~ ~ o~ ~ ~ s~c,~. SEE R~KS 14. ~E CO~TOR S~ ~MP~LY G~E ~ P~ ~R~ FOR A PER~D OF ONE (1) ~ BEGINNING AT ~E ~ OF TOT~ ~CE~CE. ~E ~TOR S~ P~M~Y i e 9 i j g y ~ST MARION NDSCAPE g' e ' g = ~. = ~. ~. ,. ~ EAST MARION FIRE DISTRICT 150-034 I D PLANT MATERIALS LIST CODED DRAWING NOTES GROUNDING NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED ~N ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL OTHER APPLICABLE LOCAL ~ PRO, DE ~2 COPP[~ GROUND RING (MIN. 1'-6" FROM OUTSlD~ ~E OF CODES TOV/~R FOUNGAIION) BURIED AT MINIMUM 50' BB. OW GRADE. ~ CONNECT FENC£ TO GROUND RING. IYPIGAL 4 PLACES. ~'~ -- ~ 2. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION SO AB TO ~ OcN.EcT T~ER ~E TO GROB.O ROC IN ,WED .IRO,~' FGR 3,~.~ ~ PR~ENT ~ ~OSS 0~ CGN~NUI~ IN THE GROUNDING SY~EM OR C~/)WELD TO TOWER BASE P!J~TE OR AS PER MANUFACTO ER'S SPECl '(~)~~ DAMAGE TO THE CONDUIT. ~ CONNECT GATE TO GATE POST ~fP. FOR 2) ~ 4/0 ~ING ~T Y~S ~ CRIMPED ON EACH END WITH ^ C~ FOR IHE CN)WELD ~ 3. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC PROCESS. LENGTH SHN_L NJ.OW FULL S~ING OF GATE. CONNECT GATE (CADWELD). POSTS TO GROUND ROD. PROVIDE A WEEP HOLE ON ROITON CONDUCTOR FOR DRN~AG~. 4. ALL GROUND CONNECTIONS ABOVE GRADE SHALL BE FORMED USING ~ ROND UTIUIY RACK SUPPORT POST TO EQUIPMENT GROUND RIRO 2-HOLE LUGS AND 1WO (2) HIGH PRESS CRIMPS. WITH ~2 AW(;. LEGEND 5. ALL EXOTHERMIC MECHANICAL CONNECTIONS TO THE GROUND RODS  CAT ilO. 3012-1 OR EQUAL <~ 9. CONNECTIONS TO THE GROUND BARS SHALL NOT BE DOUBLED UP GROUND BAR SUPPORTED. ~ - -- ~ ELECTRICAL SYMBOLS , ABBREVIATIONS AWG AMERICAN WIRE GAUGE ~ ~__~' L DWG DRAW,NC ® GROUND ROD EMT ELECTRICAL METALLIC TUBING [~J DISCONNECT SWITCH GROUND RD0 COPPERViELD IMC INTERMEDIATE METALLIC CONDUIT [] METER /5/8"~x10'-0" LONG MGB MASTER GROUND BAR I CIRCUIT BREAKER  PVC POLYVINYL CHLORIDE CONDUIT · CADWELD TYPE CONNECTION EXTERIOR GROUNDING PLAN c~o ~ ~ ~ I ! COPPER-CLAD/~ ~'P TYPICAL STEEL GROUND ROD ~/~'~~.~X~"'~-'~REPRESENTS DETAIL NUMBER etL?jgY,..., EAST MARION FIRE DISTRICT 'I EXTERIOR i FAST MARION ~ ' ~ ', ~ , ~ GROUNDING PLAN e 150-034 sc~: I~""~: I ~": ^ UTILITY ROUTING PLAN infi ni(.j engineering 150-034 TELCO PROPER'P( UNE (TYP) ELEC. METER AND SERVICE ENTRANCE PANEL · NEMA 3R ELCO BOX 30'x30'x12" WrTH 5/8' PLYWOOD BACKBOARD / / CALLED NORTH 1~iViLARGED LITY ROUTING PLAN SC. NE: CNJ. ED NOR~ EAST MARION 9245 MAIN ROAD FAST MARION, NY 11939 , EAST MARION FIRE DISTRICT A 214 ELECTRICAL NOTES 1. ALL ELECIR~CAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL OTHER APpUCABLE LOCAL CODES. 2, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONOUIT INSTAU~TION AS TO PREVENT ANY LOSS OF CONTINUI3Y IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT, ALL ELECTRICAL iTEMS SHALL BE U.L. APPROVED OR USTED CONDUCTORS SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUITS (UNDERGROUND) AND IMC CONDUITS ABOVEOROUND. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY ALL PERMIT FEES, AND SCHEDULE ALL REQUIRED INSPECTIONS. CONTRACTOR SHALL OBTAIN LOCAL POWER AND TELCO COMPANY APPROVAL AND COORDINATE WiTH UTILITY COMPANIES SERVICE ENTRANCE REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON I~IIS DRAWING. AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL PRO.DE 2' SCHEDULE 40 RVC UNDERGROUND CONDUIT wn~'( PULL WIRE BEIWEEN ELECTRICAL UTILllY DEMARCATION POINT AND KWH METER BASE. CONDUIT ROLqlNGS ARE SCHEMATIC, CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. SERVICE TO EQUIPMENT CABINETS SHALL BE 120/240 VAS. 200 AMP. 1-PHASE. CONIRACTOR SHALL DETERMINE REQUIRED NUMBER AND LOCATION OF PULLBOXES PER UTILllY STANDARDS. USE ADAPTER FROM PVC CONDUIT TO RIGID STEEL 90' BEND AND USE REDUCER TO ENTER METER BOX WITH 2' DIA. CONDUIT. AS REQUIRED PAVEMENT, GRAVEL OR LAWN AREA RESTORATION TO MATCH SLOPE AND THICKNESS OF EXISTING TELCO CONDUIT ¢' PVC SCH. COMPACTED BACKFILL (SAND OR NATIVE SOIL) WARNING TAPE ELEC1RICAL CONDUIT 4# RVC SCH. 40 UTILITY TRENCH DETAIL !/~/o~ ~