Loading...
HomeMy WebLinkAbout34307-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34094 Rte: 11/24/09 THIS u~KTIFIES that the building ALTERATIONS Location of Property: 330 BAILEY AVE (HOUSE NO.) (STREET) County TaxMap No. 473889 Section 34 Block 2 SukK~ivision Filed Map NO. __ Lot NO. __ GREENPORT Lot 7 (HAMLET) conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 14, 2008 pursuant to which Building Permit No. 34307-Z dated NOVEMBER 19, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INTERIOR ALTERATIONS WITH WOOD STOVE AND PORCH ALTERATION TO A/~ EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to WILLIAM J & JOAN P KART ( OWNER ) of the aforesaid building. SUFFOLK CO~NTYDEPARTMENT OF HEALTH APPRO%rAL N/A EI~t-rKICAL C~K'rIFICATE NO. 4019814 04/10/09 PLIERS CERTIFICATION DATED N/A //th~ized/Signature Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HAL£ 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1 Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or wpographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (8-9 form). -3. Approval of electrical installation fi.om Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate Of Code Compliance. from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Oeeupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: Old or Pre-existing Building: '// (check one) LoeationofProperty: 3'~O /'~.~['0-4 [k'~-~ (~7'v~.~ff-t~/ House No. ! Street OwnerorOwnersofProperty: _/~,/~~r~ ,J'-'"",~ ~t51~F Hamlet Suffolk County Tax Map No 1000, Section Subdivision __~/a/t Block c~ Lot Filed Map. Lot: Applicant: Permit No. ,~/'/,~f~ ~7 Date of Permit. //-/~-tO oc' Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Underwriters Approval: Final Certificate: ~ (checkone) Applicant Signature(./ BY THIS CERTIFICATE OF COMPLIANCE THE OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY NEW YORK BOARD 40 FULTON STRE~-i '~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by WILLIAM KART JOSEPH MAURO & SONS 33 CAMPUS LANE 611 BAILEY AVE LAKE RONKONKOMA, NY 11779, GREENPORT, NY 11944 Located at 611 BAILEY AVE GREENPORT, NY 11944 Certificate Number: 4019814 Application Number: 40,19814 Section: Block: Lot: Building Permit:* BDC: NS37 Described as a Residential occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on thetoth Day of April, 2009. Name QTY Rat._~e Ratimz Circuits TyPe Appliances and Accessories Electrical Heat Baseboard 1 0 .5 KVV Exhaust Fan 2 0 F.H.P Miscellaneous 1 st & 2nd floor bath room renovation Service Service Disccennect: I 150 cb ServicelPhase3w Service Rating 150Amperes Wiring And Devices ~ Fixture 4 0 Incandescent Outlet ..... 4 0 Fixtum Outlet 9 0 Gen, Purpose RecePtacle 2 0 Gen, Purpose Receptacle 2 0 GFCI Switch 9 0 Gen, Purpose seal Continued on Next Page I of 2 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by WILLIAM KART JOSEPH MAURO & SONS 33 CAMPUS LANE 611 BAILEY AVE LAKE RONKONKOMA, NY 11779, GREENPORT, NY 11944 Located at 611 BAILEY AVE GREENPORT, NY 11944 Application Number: 4019814 Certificate Number: 4019814 Section: Block: Lot: Building · NS37 Permit: BDC: Described as a Residential occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: First Floor, Second Floor, Outside, Basement, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on thel0ta Day of April, 2009. Name QTY Rate Rating Circuits Type seal 2 of 2 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. CERTIFICATION Date: Building Permit No. ~,~ ~Z ~ O '7 Owner: [..6)/ tL/,q~ ~ ..7-o /q tt~ ,4'"/z]-,"2/ ~ (Please print) Plumber: ~-~_~' ~,D 'x. "'~'~ (Please print) lead. I certify that the solder used in the water supply system contains less than 2/10 of 1% / (Pl(t(rnl~ers S ~g-natV~re) Sworn to before me this ~Y4/e*O day o~v.~.~.L~ , 200 ? Notary Public,/g~~County ilfJDITH A. SCULLY 'Notary Public, State of New YO~ No. 01SC5034538 Qualified in Suffolk County Commission Expires O~tob~' 11, blot o FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34307 Z Date NOVEMBER 19, 2008 Permission is hereby granted to: WILLIAM J & JOAN P KART 611 BAILEY AVE GREENPORT,NY 11944 for : INTERIOR/EXTERIOR ALTERATION OF EXISTING PORCH OF SFD AS APPLIED FOR. at premises located at County Tax Map NO. 473889 Section 034 pursuant to application dated NOVEMBER Building Inspector to expire on MAY 330 BAILEY AVE GREENPORT Block 0002 Lot No. 007 14, 2008 and approved by the 19, 2010. Fee $ 200.00 Authorized Signature Rev. 5/8/02 ORIGINAL TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [)~ROUGH PLBG. [ ]/~UNDATION 2ND [ ] INSULATION [~'~FRAMING / STRAPPING [ ] FINAL []FIREPLACE&CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESI .STANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARK~S. /~.~~ INSPECTOR/~~~/ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ~R'~GH PLBG. [ ~.-ItI~ULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTAI~I' CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMAR~.!~S: f~..~.~ °t~/x.~t~ -~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROU~I~ PLBG. [ ] FOUNDATION 2ND [~>]"INSULATION [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION REMARKS: DATE ~ INSPECTOR 343 o77___ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING ~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [~FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN~J~ [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ~'~- ~-~'-~/C~'-~/~Z C~,~'~/~ DATE ~r~l,D INSPEC'I'3[ON P. EPORT [ DATE PL~G ~$~ATION PER N. Y. STATE ENERGY CODE .r , -~ ] '1 "1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork, net/Southold/ Examined Approved Disapproved Expiration ~ //y ,20 ftc bcD' PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.EC. Trustees Mailto:,~za-9 F'e_~'~',/ ~'e~O Phone: (~/- Building Inspector Date 0 ,200~d INSTRUCTIONS t 'tOWN OF ~O:Lm0lp a. This application MUST be compietely filled in by typewriter or in mk and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pemfit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~,,g~',~,~,'C d_~,~-, e~. ~z,..~,. (Signature of-applicant or name, ifa corporation) ('Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder J Name of owner of premises ~Z.J/L/-~/,~,-~, :T- (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. /,;2 Oo." - t'-'t' Plumbers License No. ~,,qG[ --/o Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number ~ Street County Tax Map No. 1000 Section Subdivision (Name) Hamlet Block Filed Map No. ,~ Lot 7 Lot t 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:' a. Existing use and occupancy fi~z~t,o,-~ ~,~ c, b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost ,~ /,;2, ,ff T~-,o) 5. If dwelling, number of dwelling units [f garage, number of cars Addition Alteration Other Work floo~r~o,on~ ,vo ~x,r,r;,,,,~ ~r,e--~r,,ee~(Description) Fee (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or m/xed occupancy, specie, nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear Depth __ Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Height Number of Stories Rear Depth 9. Sizeoflot: Front 10. Date of Purchase Rear Depth Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ~ · ~ NO ~t Will excess fill be removed from premises9 YES . NO t~ 13. W I1 lot be re-graded. YES__ . 14. Names of Owner of premises /t.d~CCtnr,, ,r /~,~e~- Address {o/! /5~t~.~ 7 At ~'. PhoneNo. q 77 - ~56ie"TL. Name of Architect g',~.q~_. 7'"r ~, ~<Y~,,..J9 Address o r -Phone No -T&,oc''- ,5' Name ofContractor~Zo..O~e,~ do,o~Z e,,z~.c. Address ,~,s9 7'eee-t' ,~ Phone No. 7;7q, - '7 -7~- O 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ~ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this properg., within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide sun, ey, to scale, xx4th accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) (~O L. ,~ e ro ,o L ~,~_ being duly sworn, deposes aud says that (s)he is the applicant (Name of individual signing contract) above named, (S)~ is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is dui), authorized to perform or have performed the said work and to make and file this applicatioa: that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed m the manner set forth in the application filed therewith. Sworu to before me this /tg*~' day JUDITH A, SCULLY Notary Public, State of New No. 01SC5034538 Oualified in Suffolk Count~ Commission Expires October Signature of Applicant ~/~ 24-2? TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET, ~) VILLAGE DIST, SUB. . : ... . , . __Z,,., ~ES.~ 0 S~S. VL FARM COMM. . ~kt. Value ~ND IMP. TOTAL DATE REMARKS ~////~ AGE BUILDING CONDITION N~ NORMAL BELOW ABOVE FARM Acre Volue Per V~lue I Acre Tillable 1 Tillable ~illoble 3 ~oodlond gw~mpl~nd FRONTAGE ON WATER 3rushlond FRONTAGE ON ROAD qouse Plot DEPTH BULKH~D rotal D~K j L Bldg. <tension <tension ~2 o .,z. ? ,.. ~tension Type Roof ~rch COLOR I TRIM " ''J Lo Foundation (J'~?~ Bath Basement 1~ Floors Ext. Walls , Interior Finish Fire Place -)q O Heat Recreation Roorr ~rch Dormer reezeway Driveway arage aria 'otal Rooms 1st Floor Rooms 2nd Floo HOME IMPROVEMENT CONTRACTOR GENE E ZENDLER 12001-H 19~ bJ ZENDLER CERTIFICATE OF LIABILITY IN8URANCE Na~;ofla3 Tn~uranc~ B~ern~ of N.Y. X~lmndtm, NY ~174) Kerr~ Wolfrath TI, f~ C~.~i~-icATE I~ ISSUED AS A MA¥'rER c~ INFORMA11ON ONLY AND C~ONFERS NO R~T~ UP~ me O~PI~T; ALT~ ~E COVE~GE AFFO~ED BY ~ PO~ ClEO ~L~, INS~RS A~ORDING COVE~GE NAIC ~ ~su~ At).anttc ~psuilty ,, ' PAGE 03/0G ~ 001/004 2~1a/2oo8 ~ THE POUCIE~I OF INSURANCE LI~TED BELOW HAVE BEEN 18SUED To THE IN~URIID NAM~I:) A~OV~ POR THE POLIOy EEPJO0 INDk~TED. NOlq~/ITHSTAq DING ANY REQUIREI~NT T~RM OR OONDrrlON OF ANY OONTRACT OR OTHER DOCUMENT WITH REgPECT TO ~M~CH THIE QERTIFI~A~ MAY BE IS~U~'O OR MAY PERTAIN THE I'NSURAN(~E AFFORDED ~Y TH~ POU~I~ DE&CRIBBD H~I~EIN IS 8UBJI~OT TO ALL TH~ T~RM~ EXCLU~ONg AND COND TION~ OP 8UC POLLO E8 AGOREGAT~ LIMI'r$ SHOWN MAY HAVE BEEN REDUCED ,ay PAID CLAIUE, ' H Certlflcate ItoldeP 15 n;m~l as an Addlttoaal Zns~red wtth resPects to General Liability only. C:ANf"KLLATION ~A~ORD OORPORATIO# 1 Defiant 1610 Non-Catalytic Woodburning Stove Stove Clearance Unprotected Surfaces Protected Surfaces~ Stove Stove Stove Installed in Stove Installed in Parallel to Wall Corner Parallel to Wall Corner Side Rear Corners Side Read Corners Top exit with no connector heat shields. (A) 26" (B) 31" (C) 27" (D) 13" (E) 26" (F) 20" Flue collar shield installed (660 mm) (787 mm) (686 mm) (330 mm) (660 mm) (508 mm) Top exit with heat shields on connector. Flue collar (G) 26" (H) 18" (I) 27" (J) 13" (K) 26" (L) 20" shield installed? (660 mm) (457 mm) (686 mm) (330 mm) (660 mm) (508 mm) Top exit double-wall chim- (M) 26" (N) 23" (O) 16" (P) 10" (Q) 22" (R) 17" ney connector*. Flue collar (660 mm) (584 mm) (706 mm) (254 mm) (559 mm) (432 mm) shield installed Rear exit (S) 24" (T) 21" N/A (U) 10" (V) 21" N/A (610 mm) (533 mm) (254 mm) (533 mm) Chimney Connector Clearance Unprotected Vertical Surfaces Protected Vertical Surfaces Single-wall connector 261/2' (673 mm) 211/2" (546 mm) Single-wall connector with shields 13V2" (343 mm) 211/2" (546 mm) Double-wall chimney 181/2'' (470 mm) 171/2`` (445 mm) connector Unprotected Ceiling Surfaces Protected Ceiling Surfaces Single-wall connector 15" (381 mm) Not measured (Horizontal) Clearance to Combustibles in Front of Stove All Installations 48" (1219 mm) A minimum ceiling height of 8 feet (2.4 m) measured from the base of the stove is required for all installations. Using a listed double wall oval to 6" round connector. 1. When wall protection is used, a ceiling heat shield, 24" (610 mm) in diameter and suspended 1" (25 mm) from the ceiling must surround the pipe in installations where the chimney penetrates the ceiling. 2. The connector pipe heat shield must extend 36" (914 mm) above the flue collar. When this shield is used, a single wall pipe may continue vertically unshielded. 3. With protected wall surfaces, the rear clearance must be increased by 3" (76 mm) if the flue collar heat shield is not used. The uired when usir nnector pipe shields and always with unprotected surfaces, 14 30002850 Defiant 1610 Non-Catalytic Woodburning Stove You must connect the Defiant to a code-approved masonry chimney with a flue liner, to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney that complies with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Residential Type and Building Heating Appliance, UL 103, Figure 3 illustrates the two types. The chimney and chimney connector must be in good condition and kept clean. If you use an existing masonry chimney, it must be inspected to ensure it is in a safe condition before the stove is installed, Your local professional chimney sweep, building inspector, or fire department official will be able to inspect the chimney or provide a refer- ral to someone who can. See "Chimney and Fireplace hazards", in the appendix, for particulars. A prefabricated double.~ wall insulated chimney Am t21se~l~n~~ chimney ST241 Fig. 3 Approved chimney types. The chimney must extend at least 3' (914 mm) above the highest point where it passes through or near a roof, and at least 2' (610 mm) higher than any part of a building within 10' (3 m) horizontally. (Fig. 4) For proper draft and good performance, any chimney used with a Defiant should extend at least 16' (5 m) above the flue collar of the stove. Reference Point Fig. 4 The 2'-3'10' Chimney Rule. AC61 An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chimney should have no cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove. Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles. The chimney should be thoroughly cleaned before use. A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Mason- ry chimneys must be lined, either with code-approved masonry or pre-cast refractory tiles, stainless steel pipe, or a code-approved, "poured-in-place" liner. The chimney's clean-out door must seal tightly. A loose or leaky clean-out door can weaken chimney draft, caus- ing performance problems. ^ prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances to the High-Temperature (H.T.) Chimney Standard UL-103- 1985 (2100°F) for the United States, and High Temper- ature (650°C) Standard ULC S-629 for Canada. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. A Defiant with an 8" (203 mm) fiue collar is approved for venting into a masonry chimney with a nominal flue size of 8" x 8" (203 x 203 mm) or 8" x 12" (203 x 305 mm), and into a round flue with nominal flue size of 8" (203 mm). A Defiant with a 6" (152 mm) flue connector is approved for venting into a masonry chimney with a nominal flue size of 8" x 8" (203 x 203 mm), and into a round flue with nominal flue of 6" (152 mm). NOTE: When installed with a 6" flue collar, the Defi- ant may not be operated with the front doore open. Whatever the fiue collar size, a Defiant may be vented into larger chimneys as well. However, chimneys with liners larger than 8"x 12" (203 x 305 mm) may experience rapid cooling of smoke and reduction in draft, especially if the chimneys are located outside the home. These large chimneys may need to be insulated or have their flues relined for proper stove performance. 6 30002850 Accessories to help make the connection between stainless steel chimney liners and your Defiant are available through your local dealer. A chimney connector is the single-wall pipe that con- nects the stove to the chimney. The chimney itself is the masonry or prefabricated structure that encloses the flue. Chimney connectors are used only to connect the stove to the chimney. Single-wall connectors should be made of 24 gauge or heavier steel. Do not use galvanized connector; it cannot withstand the high temperatures that can be reached by smoke and exhaust gases, and may re- lease toxic fumes under high heat. The connector may be 6" (152 mm) or 8" (203 mm/in diameter. If possible, do not pass the chimney connector through a combustible wall or ceiling. If passage through a com- bustible wall is unavoidable, refer to the section on Wall Pass-Throughs. Do not pass the connector through an attic, a closet or similar concealed space. The whole connector should be exposed and accessible for in- spection and cleaning. In horizontal runs of un shielded chimney connector, maintain a distance of 30" (762 mm) from the ceiling. Keep it as short and direct as possible, with no more than two 90° turns. Slope horizontal runs of connector upward 1/4" per foot (6mm per meter) going from the stove toward the chimney. The recommended maxi- mum length of a horizontal run is 3' (1 m), and the total length should be no longer than 8' (2.4 m). In cathedral ceiling installations, extend the prefabricated chimney downward to within 8' (2.4 m) of the stove. This will help maintain a good draft by keeping the smoke warm, so that it rises readily. Wear gloves and protective eyewear when drilling, cut- ting or joining sections of chimney connector. Begin assembly at the flue collar of the stove. Insert the first crimped end into the stove's flue collar, and keep each crimped end pointing toward the stove. (Fig. 5) Using the holes in the flue collar as guides, drill 1/8" (3mm) holes in the bottom of the first sec- tion of chimney connector and secure it to the flue collar with three #10 x 1/2" sheet metal screws. Lift offthe griddle, and shield the stove's surface between the griddle opening and the front of the flue collar to protect the finish when you drill the front hole. Fasten each joint between sections of chimney connector, including telescoping joints, with at least three (3) sheet metal screws. The pre-drilled holes in the top of each section of chimney connector serve 30002850 Defiant 1610 Non-Catalytic Woodburning Stove as guides when you ddll 1/8" (3mm) holes in the bot- tom of the next section. Fasten the chimney connector to the chimney. Instructions for various installations follow. Figure 6 illustrates the general layout of chimney connector parts. Be sure the installed stove and chimney connector are correct dis- tances from nearby combustible materi- als. NOTE: Special slip ,, pipes and thimble sleeves that form tele- scoping joints between sections of chimney Flue Gas Direction connector are avail- able to simplify instal- lations. They often eliminate the need to Fig. 5 Chimney connector. cut individual con- hector sections. Consult your local dealer about these special pieces. Follow the installation instructions of the chimney manufacturer exactly as you install the chimney. The manufacturer of the chimney will supply the acces- sories to support the chimney, either from the roof of the house, at the ceiling of the room where the stove is installed, or from an exterior wall. Special adapters are available from your local dealer to make the connection between the prefabricated chimney and the chimney connector. The top of such adapters attaches directly to the chimney or to the chimney's ceiling support package, while the bottom of the adapter is screwed to the chimney connector. These adapters are designed so the top end will fit out- side the inner wall of the chimney, and the bottom end will fit inside the first section of chimney connector. Both freestanding masonry chimneys and fireplace ma- sonry chimneys may be used for your installation. If the chimney connector must pass through a combus- tible wall to reach the chimney, follow the recommen- dations in the Wall Pass-Through section that follows. The opening through the chimney wall to the flue (the "breech") must be lined with either a ceramic or metal cylinder, called the "thimble", which is cemented must be possible to re-open the damper to inspect or clean the chimney, If your fireplace opening height is at least 29" (737 mm), you may install a Defiant through the opening using a "positive connection" kit, available from your local deal- er. Positive connection kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 9) Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You'll find the required safe clearances for Defiant fire- place installations on Page 12. Floor protection requirements also apply to fireplace installations. This information is on Page 10. 3n. Whenever possible, design your installation so the con- nector does not pass through a combustible wall. If you are considering a wall pass-through in your installation, check with your building inspector before you begin. Also, check with the chimney connector manufacturer for any specific requirements. Accessories are available for use as wall pass- throughs. If using one of these, make sure it has been tested and listed for use as a wall pass-through, In the United States, the National Fire Protection As- sociation (NFPA) has established guidelines for passing chimney connectors through combustible wails. Many building code inspectors follow these guidelines when approving installations. Defiant 1610 Non-Catalytic Woodburning Stove Figure 10 shows one NFPA-recommended method. All combustible material in the wall is cut away from the single-wall connector to provide the required 12" (305 mm) clearance. Any material used to close up the open- ing must be noncombustible. Wall Stud Chimney 12" of Noncombustible Material Floor Protec- tion ST493 Fig. 10 An approved wall pass-through for the United States. Three other methods are also approved by the NFPA: · Placing a section of chimney connector inside a ventilated thimble, which in turn is separated from combustibles by 6" (152 mm) of fiberglass insulat- ing material. · Placing a section of chimney connector inside a section of 9" (230 mm) diameter, solid-insulated, factory-built chimney, with 2" (51 mm) of air space between the chimney section and combustibles. · Using a section of solid-insulated double-wall high temperature chimney, with an inside diameter the same as the chimney connector, at least one inch of solid insulation, and a minimum of 9" (229 mm) air space between the outer wall of the chimney section and combustibles. In Canada, The Canadian Standards Association has established different guidelines for wall pass-throughs. Figure 11 shows one method, in which all combustible material in the wall is cut away to provide the required 18" (457mm) clearance for the connector. The resulting space must remain empty. A flush-mounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted on noncombustible spacers at least 1" (25mm) clear of the wall. 30002850 9 GENERAL DESCRIPTION OF THE WORK The Contractor will be responsible for providing all material and labor with regard to the proposed alteration which will include bcff not be limited to the following: Stflp off all interior finishes, check for any damaged structural components and make all repairs as required. Make level exisflAg floor and verify structural integrity of existing floor framing components· Make all repairs as required. Remove existing windows and exterior door, supply and install new windows and door as shown ml the drawings and replace/repair exterior siding and trim in these areas to match existing. Supply and install new plumbing fixtures, fittings, water supply lines, wastes and vents as shown on the drav~flngs. Supply and install all electrical rough-in, fixtures and devices including fans and baseboard strip heating as shown on the drawings. Install new Insulation in walls and ceilings as noted on drawings and general notes· Supply and install Y~" NCR. gyp. bd, on all ceilings and wal~s finished with tape and three coats of spackle. Apply three coats of paint on all ceilings, walls and trim with finish as selected by Owner. Supply and install recessed medicine cabinet as selected by Owner. Supply and install finish flooring in all altered areas using a material as selected by Owner. Coordinate with Bugdillg Department for all necessa~7 inspections, Provide solder certificate, underwriters certificate and certificate of occupancy upon complstiofi of the work. It is the intent of the Drawings and Specifications to provide a completely finished project weather details of same are shown or implied. All labor and materials required to produce this end result shall be included in Contractor's scope of work. PLUMBER CERTIFICATION ON LEAD CONT~ENT BEFORE CERTIFICATE OF OCCUPANCY SOLDER USEiD IN WATER SUPPLY SYSTEM DANNOT EXCEED 2/10 OF 1% LEAL). STORM WATER RUNOFF COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOLm4OLD TOWN ZBA BOUTHOCD TOWN pd~NNli~ BOARD BOLm,IoU3 TOWN TRUSTEES .. trY.S. 9hO ALL CONSTRUCTION sHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. CERTIFICATION OF NAILING &'cONI~[q:~DNS NAt LIi~ ~REQLIIR[~I~TIONS OCCUPANCY OR USEIS UNLAWFUL WITHOUTCERTIFICATE OF OCCUPANCY APPROVED AS NOTED NOTIFY BUILDING DEPARTMENT AT 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - ~0 REQUIRED FOR POURED CONCRETE 2. ROUGri - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL ME~ THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS· ONDERWRffERs CERTIEtG~TE · ,~REQUIRE1) , ..- architect ~'~-- 1230 TraveLer Street South old N.Y. 11971 %'~2/~'~. ~ '~'~ 631- 765 - 5455 ~_ i ~:~'T'~ .... -':- ~.~ ~_.~~1~ -- 12B0 Traveler Street Southold N.Y. 11971 ~ E ,.~ ~.- N~WO~TO .~~~ 631 - 76~,- 5455 GENERALNOTES: 1. Contractors wori( is to conform'to all local ordinances and NYE Bul[dir~g and Energy Conservation .cone, retest edition(s). 2. ~ll Electrical and?lumbing work shall be governed by all National~ State and Local Codes, latest edit[on(s). 3. Ag connections of water supply lines are to be made ~vith 95/S solder as approved by Suffolk County Department of Health Services with ceR~ticate of compgance provided upon completion. Shower to he equipped with "scald proof" 5. Contractor(s) shall verify ag field conditions and dimensions and will be responsible for same. Any discrepancies shag be reported to the Architect Immediately. 5. Contractor(s) w~ll cooperate wig1 all other trades and.will complete work in accordance with best standards and practices. ?. Ali dimensions are neminaJ arid t~ke precedence over scale. All abbrevlatio ils are standarn. 8, All items of work on the drawings are new, uldess otherwise noted. 9, Proprietary names idenfltying items of work are used solely to prescribe standards of construction. items of equal quality may he submitted to the Architect for consideration un,ess noten otherwise. 10. All woon frame construct[on sha~l conform to the American Forest & Paper Association "WOOD FRAME CONETRUCTION MANUAL" 1995 SBC - HiGH WIND, latest edition. 11. All high winn resistant structural metal connections shown on the drawings, or required by code from the roof to the foundation are to be manufectqred by "EIMPSON Strong-Tie" and be "Z-Vax" coated. Connectors which are near, on or below grade must be fabricated of type 3t6 stainless steel. 12. Ag wood framing members shall have an allowable extreme fiber stress equal to or greater than structure[ grade Douglas Fir: 14. 15. 16. 17. 13, 20. 22. 23. 24. 25, 27. Contractor{s) i sta~'e to fol~ow ali manufacturers' instructions, shop drawings, as weti as installation manuals when installing any prefabricated item(s). Existing floor joists and entire structural shell of altered area are to be ~xamlned by the contracto~" to verify structqrai mtegr[ty and absence of any rot, decay or insect infestation, Evidence of any_ such damage is to be reported to the A~ch tect jmn~edipt · y. L ,Z Provide =/=" moisture resistant gypsum board on walls and ceilings of entire altered are~ including walls and ceiling of tub shower area. All firestopplng sball be of an approved non~Co~lbuStible ~aterial and installed in accordance with Exterior wails and ceiling are to be stripped of existing finishes So aa to allow instagafion of insulation as fogows: 3-~/2" (R.13} Krgft.fac. e~d baits withrvapor barYielr facing warrr~ side of building at all exterior walls. Ceding/Roof insulation shall b~ 3~112" (R-3g or IOA/4" R.31~) K~aft-faced botts ELECTRICAL NOTES : 1. All electrical work i~ to be completed by a licensed electrician and is to comply with all National, state & Local codes in addition to UnderWriters standards as they apply. Electrical work must be pertonned by mechanics skilled in their respective trade and shall present appearance and function typical of best trade practices. Work and/or materials not installed in this manner will be repaired or replaced at no expense to the owner. 2. All work shown on Ihe drawings is d. lagrammaEc. Electrical Contractor shall coordinate his work with ali other trades. D~ not scale drawings for fixture or device locations. Verify all fixture, outlet & equipment Iocafions with OW~Y ~r prior to commencing work. Coordinate all work with Vanity layout as well as ail Apptianc~ and Equipment locations. 3, Provide code- s~ze grounding conductors for any equipment. Provide light in crawl space a~ea on switch adjacent to access opening. 5. Provide Ground Fault protection circuit breakers or devices for all receptacles adjacent to lavatories and as othe~vise required. 6. Provide adequate receptacles and connections ~'or all appliances as well as venting of clothes dryer and exhaust fans to the exterior of the building, 7. All fixtures are to be equipped with 130 volt "watt miser" lamps where applicable. S. Electrical Contractor shall provide electric baseboard strip hoofing in altered areas on separate thermostat(s). EJectrical Contractor shall furnish a Certiticate of inspection from the Board of, Fire Underwriters upon completlon of the work under his contract, Such ceRificate shag indicate the approval of the work instalIed and of the complete electrical system, 10. Jt is the intent of the Drawings and SpeciticaUons to provide a complete and operational electrical system weather detags of same are shown or impged~ All labor and materials required to produce this end result shaft be included in Contractor's scope or work. 11. Any reference to "as per Owner" or "as directed~by Owner" refers to Mr, & Mrs. William Kart. ELECTRICAL LEGEND RECESSED INCANDESCENT LIGHTING., WALL~MOUNTED 220 VOLT CIRCUIT AND FIXTURE HALO #H-.5 WITH #501 OW TRIM ~ RECEPTACLE TO SERVICE FUTURE OR APPROVED EQUAL - · LAUNDRY EQUIPMENT. VANITY LIGHT FIXTURE JUNCTION BOX FOR 220 VOLT CIRCUIT AS SE~.ECTED BY OWNER ~ TO SERVICE STRIP BASEBOARD ELECTRIC HEATING UNIT COMBINATION HEAT LAMP AND EXHAUST THERMOSTAT DEVICE - QUANITY FAN ON SEPARATE SWITCHES, DUCTED TO ~ AND FINAL LOCATIONS TO BE THE EXTERIOR, CONFIRMED WITH OWNER WALL MOUNTED SWITCH "DECORA" DEVICE TO BE MOUNTED ROCKER STYLE - SINGLE POLE OR ~ F'~.. ~ AT COUNTER HEIGHT MULTI-WAY AS REQUIRED WALL MOUNTED 110V, DUPLEX RECEPTACLE DEVICE TO BE GROUND FAULT "DECORA" STYLE LOCATIONS AND MOUNTING -~-~t=~.--.~ .- PROTECTED HEIGHTS TO BE CONFIRMED WITH OWNER GARRETT, A. STRANG architect 1230 Traveler Street Southold N.Y. 11971 631 -765- 5455