HomeMy WebLinkAbout34215-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-34046
Rte: 10/27/09
THIS CERTIFIES that the building ADDITION TO COTTAGE
CUTCHOGUE
I~Dcation of Property: 2950 VA/~STON RD
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 111 Block 5 I~Dt 7.2
Filed Map NO. __ Lot No. __
Subdivision
conforms substantially to the Application for Building Permit heretofore
filed in this office dated OCTOBER 9, 2008 pursuant to which
Building Pezmit No. 34215-Z dated OCTOBER 9, 2008
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is GARAGE ADDITION TO AN EXISTING COTTAGE AS APPLIED FOR WITH NO HEAT OR
AIR CONDITIONING PER ZBA #6181, DATED 9/4/08.
The certificate is issued to RF & MA GALL~GHER TRT
(OWNER)
of the aforesaid building.
S~P~)LKC~DL~YDEPART~ENTOF~%L/~qAPPRO%KAL N/A
~EC~RIC3%L C~TIFICA~ NO. 11062 10/13/09
PLIERS c~TIFICATION DA'£~ N/A
Rev. 1/81
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPA=RTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-34045 I~ate: 10/27/09
THIS U~aTIFIES that the building ADDITION TO DWELLING
Location of Property: 2950 VANSTON RD CUTCHOGUE
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 111 Block 5 Lot 7.2
Subdivision Filed Map No. __ Lot No. __
conforms substantially to the Application for Building Permit heretofore
filed in this office dated OCTOBER 9, 2008 pursuant to which
Building Permit No. 34215-Z dated OCTOBER 9, 2008
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR.
The certificate is issued to RF & MA GALLAGHER TRT
( OWNER )
of the aforesaid building.
SUFFOLK COUNTYDEPARTMENT OF HEALTH APPROVAL
EL~crKICAL C~KTIFICATH NO.
PLIERS CERTIFICATION DA'r~a3
N/A
N/A
N/A
Signature
Rev. 1/81
~_ ~ 765-1802
-- --" =-~-'------APPLICATIONFOR CERTIFICATE OF OCCUPANCy
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
· A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of wator supply and sewerage4isposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sw0m statemen~ from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installatious, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-confoming uses, or buildings and "pre-existing" land uses:
i. Accurate survey of property showing all property lines, streets, building and uunsual natoral or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, AccessoD, building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Oeeupancy- Residential $15.00, Commercial $15.00
Date. /~9/c~3/O7
New Coustmction: [// Old or Pre-existing Building:
Location of Property:
(check qne)
House No.
Owner or Owners of Pmperty.-~eh*TOLl ~_~
Suffolk CountyTax Map No 1000, Section
Street
Block _5--
Lot
Subdivision
Permit No. c~ t4a7 I ~-
Health Dept. Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $ ~ff]', O(2)
5 qc q5
Filed Map. Lot:
Dateofi'ermit. h' e Appli--t:
Underwriters Approval: ~
Final Certificate:
(check one)
/ Applicant SignatUre /
+
SUFFOLK
BUREAUof
ELECTRICA~
I N S P E C 1 0 R S,~ n c.
40 Nottingham Drive, Middle Island, NY 11953
Telephone:631 4958136 · Fax:631 9806455 · E-Mail:SBEIGS@gmail.com
CERTIFICATE OF ELECTRICAL COMPLIANCE
Applicant:
Rough Tn Inspection Date:
Application No.:
County Tax Map No.:
Express Electric
September 2,2009
11062
Certificate No.:
Final Inspection Date:
Building Permit No.:
11062
October 13,2009
This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or
work described below, installed by the applicant named above, located at the premise of and not after the final
inspection date above:
Owner: Ronald Gallagher
Site Location: 2950 Vanston Road, Cutchogue, NY 11935
Owner's Address (if different):
~ Residential ~ Indoor
~_-1 Commercial [] Outdoor
[] New [] Renovation
~ Addition [] Survey
Single Phase Heat
Three Phase Hot Water
Main Panel AC Cond
Sub Panel AC Blower
Transformer Appliances
Disconnect Switches
GFCI Breaker Heat Pump
Other Equipment:
4
[] Basement [] Service [] Shed
[] First Floor ~ Pool ~ Hottub
[] Second Floor [] Attic [] Garage
Other:
INVENTORY
Duplex Recpt 9 Ceiling Fixture 2 HID Fixtures
GFCI Recpt 1 Wall Fixture Smoke
Single Recpt Recessed Fixture 4 CO Detect
Range Recpt Flourescent 2 Pumps
Dryer Recpt Emergency Time Clock
Twist Lock Exit Fixtures TVSS
Electric Heat Pool Luminaire Exhaust Fan
The electrical work and/or equipment described above were inspected and appear to be in compliance
with local, state and national electrical code requirements and this office.
Applicant: Express Electric
inspected By: Roger Richert
License No.: 3653-ME
Date Of Certificate: Oct '14,2009
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 34215 Z
Date OCTOBER 9, 2008
Permission is hereby granted to:
RONALD F GALLAGHER
2950 VANSTON RD
CUTCHOGUE,NY 11935
for :
ADDS/ALTS TO AN EXISTING SINGLE FAMILY DWELLING & ADDS/ALTS TO AN
EXISTING ACCY COTTAGE AS APPLIED FOR PER ZBA. 2 COS REQUIRED.
at premises located at 2950
County Tax Map No. 473889 Section 111
pursuant to application dated OCTOBER
VANSTON RD CUTCHOGUE
Block 0005 Lot No. 007.002
9, 2008 and approved by the
Building Inspector to expire on APRIL 9, 2010.
Fees 340.00 ~~~t/
ORIGINAL
Rev. 5/8/02
~PPEALS BOARD MEMBERS
Gerard E Goehringer, Chairman
Ruth D. Oliva
James Dinizio, Jr.
Michael A. Simon
Leslie Kanes Weisman
Mailing Address:
Southold Town Hall
53095 Main Road · EO. Box 1179
Southold, NY 11971-0959
Office Location:
Tmvn Annex/First Floor, North Fork Bank
54375 Main Road (at Youngs Avenue)
Southold, NY 11971
http://southoldtown.north fork.net
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD
Tel. (631)765-1809 · Fax (631)765-9064
FINDINGS, DELIBERATIONS, AND DETERMINATI4) MEETING HELD SEPTEMBER 4, 2008
ZBA it 6181 - RONALD F. and MARILYN A. GALLAGHER, APPLICANTS
PROPERTY LOCATION: 2950 Vanston Road, Cutchogue CTM 111-5-7.2
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property
under consideration in this application and determines that this review falls under
the Type II category of the State's List of Actions, without further steps under
SEQRA.
SUFFOLK COUNTY ADMINISTRATIVE CODE: This application has been referred
as required under the Suffolk County Administrative Code Sections A 14-14 to 23,
and the Suffolk County Department of Planning reply dated June 24, 2008 states
that the application is considered a matter for local determination as there appears
to be no significant county-wide or inter-community impact.
PROPERTY FACTS/DESCRIPTION: The subject property is a non-conforming
29,852 square foot parcel in the Residential R-40 District, measuring 71.94 feet and
194.50 feet along Old Cove Road to the north, 153.0 feet to the east, 318 feet to the
south, and 66.19 feet on Cutchogue Harbor to the west. The property is improved
with a single-family, two-story dwelling and a single-stow accessory unheated
cottage with an adjoining garage, as shown on the survey by Roderick Van Tuyl, P.
C., dated September 7, 1994.
BASIS OF APPLICATION: Request for Variances under Section 280-121 A, based on the
Building Inspector's April 9, 2008 Notice of Disapproval concerning a proposed addition to
the existing garage which is attached to a nonconforming cottage, accessory to a primary
dwelling.
FINDINGS OF FACT
The Zoning Board of Appeals held a public hearing on this application on August 21,
2008, at which time written and oral evidence were presented. Based upon all
Page 2 - September 4, 2008
ZBA # 6181 - R. and M. Gallagher
CTM 1000-111~5-7.2
testimony, documentation, personal inspection of the property, and other evidence,
the Zoning Board finds the following facts to be true and relevant:
RELIEF REQUESTED: The applicants seek a variance for a two-car garage addition,
~pl~ac~ of the existing one-car garage.
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials
submitted, and personal inspections, the Board makes the following findings:
1. Town Law §267-b(3)(b)(3)(1). Grant of a variance for the addition to convert an
existing one-car garage attached to a preexisting accessory cottage to a two-car
garage will not have an adverse effect on the character of the neighborhood or be a
detriment to nearby properties. The house is at the end of a long private road.
There are no other houses within 100 feet.
2. Town Law §267-b(3)(b)(2). The benefit of adding garage space for a second car
cannot be achieved without a variance, given the nonconforming nature of the building
that houses the garage.
3. Town Law §267-b(3)(b)(3). The variance sought for a larger garage is not substantial.
The garage addition will amount to 500 square feet and will occupy a portion of the
driveway adjacent to the existing one-car garage.
4. Town Law §267'b(3)(b)(5). The difficulty was created when the cottage and
garage was built prior to the existence of zoning requirements. The Building
Department issued a pre-existing certificate of occupancy for the cottage with garage
on May 29, 2008.
5. Town Law §267'b(3)(b)(4). No evidence has been submitted to suggest that grant
of this relief will have an adverse impact on physical or environmental conditions in
the neighborhood.
6. Town Law §267-b. Grant of the variance is the minimum action necessary and
adequate to enable the applicant to enjoy the benefit of a two-car garage addition,
while preserving and protecting the character of the neighborhood and the health,
safety and welfare of the community.
Page 3 September 4, 2008
ZBA# 6181 - R. and M. Gallagher
CTM 1000-111-5-7.2
RESOLUTION OF THE BOARD: In considering all of the above factors and
applying the balancing test under New York Town Law 267-B, motion was offered by
Member Simon, seconded by Member Weisman, and duly carried, to
GRANT the variance as applied for, as shown on the May 19, 2008 Diagrams A-
1, A-2 and A'3 prepared by Mark K. Schwartz, Architect, subject to the following
CONDITION: That no heat or air-conditioning shall be permitted in the
accessory cottage.
Any deviation from the variance given such as extensions, or demolitions which are not
shown on the applicant's diagrams or survey site maps, are not authorized under this
application when involving nonconformities under the zoning code. This action does not
authorize or condone any current or future use, setback or other feature of the subject
property that may violate the Zoning Code, other than such uses, setbacks and other features
as are expressly addressed in this action.
The Board reserves the right to substitute a similar design that is de minimus in nature for
an alteration that does not increase the degree of nonconformity.
Vote of the Board: Ayes: Members Goehringer (Chairman), Oliva, Simon and
Weisman. Absent was Member Dinizio. This Resolution was duly adopted (4-0).
,' GEP~ARD P. GOEHRINGER, CHAIRMAN 0/l/ /2008
c~---2~pproved for Filing
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
/~FOUNDATION 1ST [
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]RRB RESISTANT CONSTRUCTION [
] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
] RRE RESISTANT PENETRATION
REMARKS:
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
] FIREPLACE & CHIMNEY
] FIRE RESISTANT CONSTRUCTION
REMARKS:__
] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]FIRE RESISTANT CONSTRUCTION
[ ] ROUGH PLBG.
[~INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
REMARKS:
INSPECTOR ~__~-~T ~
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
FOUNDATION 1ST
FOUNDATION 2ND
FRAMING / STRAPPING
FIREPLACE & CHIMNEY
FIRE RESISTANT CONSTRUCTION
[ ] ROUGH PLBG.
[ ] INSULATION
~)~ FINAL
] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENEI'RATION
REMARKS:
DATE
INSPECTOR__~-~. ~
COM]MENTS
D 12',rSPECTION REPORT DATE
FOUNDATION (1ST)
FOI.~_q'qDATION (2ND)
ROUG~/FP._a~MING &
pI.,LrM3~I2~ G
iNSULATION PER N. Y.
STATE ENERGY CODE
F~NAL
A/)DITIONAL COM/VIENTS
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
SoutholdTown. NorthFork.net
Examined / ,20
Expiration ,20.__
PERMIT NO.
BUILD1NG PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying'?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check J
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Storm-Water Assessment Form
Contact:
Mail to:
APPLICATION FOR BUILDING PERMIT
Date ,20
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship.to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant or name, ifa corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises Rot'VO/~,5 F,
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade s License No.
Location of land on which proposed work will be done:
House Number Street
Hamlet
//¢35-
County Tax Map No. 1000 Section /// Block Obi'- Lot l~, Z
Subdivision Fred Map No. " Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy
b. Intendeduseand occupancy
3. Nature of work (check which applicable): New Building.
Repair Removal
Estimated Cost
If dwelling, number of dwelling units
If garage, number of cars
Addition )~ Alteration
Demolition Other Work
Fee
(Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
Dimensions of existing structures, if any: Front / i'
Height ! q / Number of Stories
Depth
Dimensions of same structure with alterations or additions: Front ~ O i o 'f
Depth ~o' ~ 'f Height /6' b'''~/ Number of Stories
Rear
/
8. Dimensions of entire new construction: Front
Height Number of Stories
Rear .Depth
9. Size of lot: Front
Rear _Depth
10. Date of Purchase
Name of Fenner Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded? YES NO__
14. Names of Owner of premises
Name of Architect
Name of Contractor
Will excess fill be removed from premises? YES __ NO__
Address Phone No. ).3q- ,,2~--~ q
Address Phone No
Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__NO __
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES__
· IF YES, PROVIDE A COPY.
NO
STATE OF NEW YORK)
..-- SS:
COUNTY Ob2 i) .~.' '){ I.(L
~Z~-~/c?/~/~ ,K'JLL ~,~0{/~'/~[ ' being duly sworn, deposes ~d says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
S~v~3~before me thi,~
? r_~~'' day o
, - v - - - t ~ ~ ;. ~iELANiE DOR0SKI
Nota~onc NOT~Y PUBLIC, State of New
No, 01D04634870
Qualified in Suffolk Coun~
~on ~ir~ 8eptembe~ 30- (~
Signature of Applicant
FORM NO. 3
NOTICE OF DISAPPROVAL
DATE: April 9, 2008
TO:
S&S Construction (Gallagher)
PO Box 1637
Mattituck, NY 11952
Please take notice that your application dated April 3, 2008
For additions and alterations to an existing accessory cottage at
Location of property: 2950 Vanston Road, Cutchogue
County Tax Map No. 1000 - Section 111 Block5 Lot 7.2
Is returned herewith and disapproved on the following grounds:
The proposed additions and alterations are not permitted pursuant to Article XXII Section 280-121 A,
which states that such building or use
"Shall not be enlarged, altered, extended, reconstructed or restored or placed on a different
portion of the lot or parcel of land occupied by such use on the effective date of this chapter,
nor shall any external evidence of such use be increased by any means whatsoever."
This Notice ~
Z~
lpproval is based on plans dated February 4~ 2008~ by Mark Schwartz~
Signature
Note to Applicant: Any change or deviation to the above referenced application, may require
further review by the Southold Town Building Department.
CC: file, Z.B.A.
Town of Southold
Erosion, Sedimentation & Storm-Water Run.off ASSESSMENT FORM
Item Number;
2
PROPERTY LOCATION: S,C,T,M, #:
,~_~_ /// .,¢.¢ ¢, Z
District Section Block Lot
(NOTE: A Chock Mark (~) for each Question is Required for a Complele Application)
Will this Project Retain All Storm*Water Run-Off Generated by a Two (2") Inch Rainfall on Site?
(This item will include all run-off created by slIe clearing and/or construction activities as well as all Site
improvements and the permanent creation of impervious surfaces.)
Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location?
This Item shall include all Proposed Grade Changes and Slopes Con(rolling Surface WaterFIowl
3
THE FOLLOWING ACTIONS MAY REQUIRE THE 8UBMI881ON OF A
STORM-WATER, GRADING~ DRAINAGE AND EROSION COHTROL FI. AN
CERTIFIED BY A DESIGN PROFE8810HAL IN THE STATE OF NEW YORK,
4
Will this P?ojecl Require any Land Filling, Grading or Excavation where there is a change to the Natural
Existing Grade Involving more than 200 Cubic Yards of Material within any Parcel?
5
Will this Application Require Land Disturbing Activities Encompassing an Area In Excess of
Five Thousand (5,000) Square Feet of Ground Surface?
6
Is there a Natural Water Course Running through the Slle?
Is INs Project within the Trustees juHsdiclion or within One Hundred (100') feet of a Wetland or Beach?
7
Will there be Site preparalion on Existing Grade Slopes which Exceed Fifteen (15) feet of Vedical Rise to
One Hundred (100') of Horizontal Distance?
8
9
Will Driveways, Parking Areas or other Impervious Surfaces be Sloped to Direct Storm-Water Run-Off
into and/or in the direction of a Town fight-of-way?
Wilt this Project Require the Placement of Material, Removal of Vegetation and/or the Construction of
any item Within the Town Right-of-Way or Road Shoulder Area?
(This item wilt NOT include the Installation of Driveway Aprons.)
Will this Project Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercourse?
Yes No
NOTE: If Any Answer to Queslions One through Nine is Answered with a Check Mark in the Box, a Storm-Water, Grading,
Drainage & Erosion Control Plan is Required and Must he Submitled for Review Prior to Issuance of Any Building Permftl
EXEMPTION: Ye~s
Does this project meet the minimum standards for classification as an Agdcullural Projecl?
Note: If You Answered Yes to this Question, a Storm-Water, Grading, Dra nage & Erosion Control Plan is NOT Required! ~
RD
STATE ()F NEW YOP, K,
COl JR YY OF .,..~ ~ ... SS
Ox*ne] and/o[ rcplescutabve of tim Owner o[ (J)~*rI~e]IS, al/d iS (Itl]5' allthol izod to perlorm or have pedormed Oe sad work and to
make and file tlus application; d~at MI statements contained in ~is application ate a~e to the best of}tis b~owledge ~d bdiel;
d~a~ d~c work will toe [>et formed in dze ru~mei sci forth m tim api)lication filed he~ex*qth.
Sworn Ir> I)e~o~ me d~is;
MELANIE DOROS~ (Slgnalure of
~OT~aV ~UaL;C, si~t~ u; N~.
FORM - 06/07 No. 01D04634870
Oualified in Suffolk Coun~ ~/~/0
Commission ~ires ~eCemb~ 30,~ ' ~
OF SOUTHOLD ~OPERTY
RECORD CARD
OWNER
EOR~,E~ OWWER ....
STREET
IS
VI LLAGE
W
DISTRICT SUB.
ACREAGE ~-~ ,
_~:~.~ ~ i~z-/~F'
TYPE OF BUILDING
LOT ,~
Farm Acre Va ue Per Acre
Tillable 2
Zilleble 3
Wcodl~nd
Swampland
Brushlanc~-
House Plot
Total
Extension
Extension
Foundation
Basement
Ext. Walls
Bath
Floors
Interior Finish
Fire Place Hea~
Porch Attic
Porch Rooms 1st Floor
Patio , Rooms 2nd Floor
Driveway
Y
Extension ~ i
I Foundation
Basement
$
o
TOWN OF SOUTHOLD
EXISTING
DINING ROOM
(~XPA~P~P)
N~WPNIN~
~MDV~ ~I~IN~ WA,[. %~
EXISTING
KITCHEN
EXISTING
ENTRY
EXISTING
COVERED PORCH
DINING RM
ADDITION
2~ W~L
FIRST FLOOR PLAN
1/4."= 1'-O"
',I~W pO~,DAqON -
FOUNDATION PLAN
1/4"= 1'-0"
APPROVED AS NOTED
765-1802 8AM TO 4 rM FOR THE
FOLLOWING INSPECTIGh~S.
1, FOUNDATION' TWO REQgIRED
~, ROUGH ' FRA~ING & PLUMBING
3. INSULATION
4, FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C,O
ALL CONSTRUCTION SHALL MEET THE
~ BEQUiREMENTS OF THE CODES OF NEW
~' YORK STATE, NOT RESPONS[BLE FOR
~~ DESIGN OR CONSTRUCTION ERRORS.
NEW YORK STAT2 & TOWN uuu~o
~AS REQUIRED AND cONDITIONS OF
~ SOU~OL~ TOWN TRUSTEES
~, N.Y,S. DEC
~GE AL~ONSTRUCTION 8HALL
ADDZ~ON MEET TH~REQUIREMENTS~N OF THE
-PROPOSED CODES ~ EW YORK STATE.
DINING RM
~D~ 1 ION EXISTING ~
UNDER~RS CERTIFI~
~,t STORY . ,-ftFtoATtOfl OF I~litEO
FR. COTTAGE t
~ ,-~' g LiNt. AWFUL
,,
OFv'C,b ,' ,
O-111-05-7.2
r
h~ ........... r~
I I [I
REVISIONS
JOB #:
~E~RU~RY 4, 2008
A
o,O CL.O .s
N
~W 2~
N0¢¢~ d,C, 1'0 VERIFY
~Xl~NId POUMPATION
WAbt.5 ANP FOOfINd~
EXISTING
II
I!
GARAGE
EXISTIN
J ~1~ KITCHE~
I /
/
J ,1 ~EXISTING
I / \ l 'x ~,~1-
-,I/ L_
il
(~ FOUNDATION PLAN ,/,,.,,:~'-o"
1/4"=1'-0"
(~ SECTION
1/4"= 1 '-0"
[2
(~ ROOF PLAN
1/4"= 1 '-0"
12
Z
DRAWN: 3G
SCALE: 1/4"=1'-0"
.]OB #:
FEBRUARY 4., 2008
SHEET NUHBER:
A-2
(~ NORTH ELEVATION
1/4"= 1 "-0"
(~ SOUTH ELEVATION
1/4"= 1"-0"
~ION
(~ EAST ELEVATION
1/4"= 1 "-0"
REVISIONS
,,, g
0 "'
· 'r' ~ >_
DRAWN: .1G
SCALE: ~/4"=1'-0"
30B #:
FEBRUARY 4, 2008
SHEET NUMBER:
WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS
USE THE FOLLOUJIN APPROX/E USP METAL CONNECTOt 5 FOR PF OPER LUIND REGIGTANT 4 CONGTF. UCTION, FOLLOLU MANUFACTUF E'$ EGOMMENDED INGTALLATION INSTF.%ICTION5 TO ACHIE\/E MAXIMUM
KING STUDS
RAFTER -- .~ ~
· HEADER LEDGER BATHTUB
SIDEWALL DOUBLE JOIST
USP NUMBER :)ESCRIPTIO~ APPLICATION
FLOOR
1ST, ADS5 HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS l ~
ANCHOR TO FOUNDATION W/ANCHOR BOLTS
CONNECT TO 1 SIDE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION APPLICATION BATH / SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT
2ND. ADS5 HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR
ANCHOR PLATES OF 1ST, FLOOR. CONNECT THROUGH ALL OPENINGS LSTA12 1-1/4"xt2" 20ga. STRAF APPLY TO EACH JACK STUD ROOF LSTA24 1-1/4"x24" 20ga. STRAP APPLY OVER RIDGE TO EACH RAFTER 2xG-2x8 LS26 18ga. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER JOIST DIRECTION WITH (2) JOISTS. UNDER WALL.
THE FLOORS TO EACH OTHER W/THREADED ROD, ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR ~PPLY TO EACH CRIPPLE STUD 2X10 LS210 18ga, SLOPE HANGER APPLY TO EACH RAFTER / LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS, PROVIDE
BLOCKING @24"OC
WALL STUD ..~~
,,~ / ~ "-:~ ~ VENTS SELECTED AND
METAL STRAP ..~ / ~'~...~ LOCATED BY CONTRACTOR
CRICKET AT TOP.SIDE OF
RIM BOARD O /CHIMNEY ~ENTILATION CHANNEL
~ RAFTER S REQUIRED
SILL PLATE(S) O // WALL SHEATHING )~AFTEt~5 ~MAINTAIN
FOUNDATION ' O ' - - ' ~ % ~ / BARRIER TO LAP FLASH NG ~' ~ ~ 2x4 SOFFIT JOIST
- / / FINISH WALL AND MOISTURE . ~ ~ ~ ~ 2x4 LEDGER BLOCKING
STAPPING TO BE A~ACHED TO WALL STUDS ~48"OC
AND ALL WINDOW/DOOR OPENING JACK STUDS ~ ~ ~ AT WALL-- MAINTAIN GAP ATTIC SHALL BE PROVIDED WITH A ~ % ~ ~, FAS~
FLOOR JOIST DEPTH ~SP NUMBER DESCRIPTION APPLICATION % ~ ~ ~ BE~EEN WALL FINISH AND MINIMUM NET FREE VENTILATING AREA ~- ~ ~ ....
INSTALL 4'0" O.O. NOT LESS THAN 11150 OF THE AREA ~¢ ~ J~ GUTTER WOOD GIRDER
~ / %/ ~ THE SPACE VENTILATED. ALL OPENinGS ~CONTIN SCREENED VENT
4" - 8" LSTA24 1-1/4"x24" 20ga, STRAP AND JACK STUDS ~ ~ SHALL BE COVERED WITH CORROSI~- ~ ~ ~CO .
ON ALL OPENINGS . % ~ / /~ . PROVIDE HEMMED EDGE AT / RESISTANT METAL MESH WITH MESh ) LCONTIN. SOFFIT / E~. PLYWOOD
INSTALL 4'0" O,C. ~ / // / ~ / FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTION APPLICATION I OPENINGS OF % INCH IN DIMENSION.
8" - t4" LSTA30 t-1/4"x30" 18ga, STRAP AND JACK STUDS ~ /~ ~ AND SO AS TO MAINTAIN AIR OFFITED
ON ALL OPENINGS ~ ~ / // ' -. ~ ~ ~ GAP TO PREVENT CAPILLARY 4" - 6" RAFTER RTl0 10-3/4" x 18ga. TYDOWN ANCHOR CONNECT TO
/ ~ /~ ~>~. ~ ACTION EACH RAFTER
INSTALL 4'8" O.C. PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND
CONNECTTO ~OO~ ~ENTIL~TION / OVER BEARING WALLS AND HEABERS
14"-16" LSTA36 1-1/4"x36"18ga, STRAP AND JACK STUD8 ~ j/~ /~~ B"-12"~FTER RT20 2~-I/8"x2Oga. TYDOWNANOHOREACHRAFTER
ON ALL OPENINGE ~ ~ ~,, / ~ % KEEP ROOFING NAILS OUT 5OFFITED EASE DETAIL
2ND. FLOOR WALL
ROOFING LAPS BASE
I¢ ~ ~ ~~ ~¢SE ~ASHING WRAPS CORNERS, RAFTER 0 RIDGE CAP OF SAME
~ / ~ ~ ~ EXTENDS UNDER SHINGLES AT /~ %~ MATERIAL AS ROOFING
/ ~ ~ % % SIDES 4 INCHES AND LAPS /~/ %%% % NAILED TO SHEATHING
SHINGLES AT BASE MfN. 4 INCHES ~ ~%%~ THROUGH VENT
,
, , GIRDER/HEADER
1ST. FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS ~48"OC WOOD JOIST
AND ALL WINDOW/DOOR OPENING JACK STUDS ~ETAL FLASHING AT ALL E~VES, SIDEWALLS, WALL STUD ~ ~ ~ ~
FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION AN~ R~KE5 -- PROVIDE NE~ED E~E5 ~O
INSTALL 4'0" C.C. A5 TO FO~M DRAINAGE CHANNEL5 ~ND ~F~ ¢~
4.. 8. LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS P~E~ENT CAPILLA~ ACTION LOCATION JSP NUMBER DESCRIPTION APPLICATION
ON ALL OPENINGS~ PRE-MANUFACTURED KEEP SHEATHING MIN. 1-t/2" ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH
CONNECT EACH RIDGE VENT FOLDS FROM PEAK TO ALLOW FREE
INSTALL 4'0" O.C, RAFTER/PLATE RTl5 ~DOWN ANCHOR ~FTER TO PLATE OVER RIDGE TO THE PROPER STEEL CONNECTOR.
8"- t6" MSTA48 1-t/4"x48" 16ga. STRAP AND JACK STUDS AIR PASSAGE
CONNECT OVER CONFORM TO SLOPE IF ABLE, SET FIR JOISTS APROX, 1/2" HIGHER THAN LVL HEADERS
ON ALL OPENINGS PLATE~ALL SPTH4 STUD PLATE ANCHOR PLATES TO EACH STUB OF ROOF TO ALLOW FOR SHRIN~GE, & REDUCE BUMP OUTS
DBL. SILL PLATE ,' ~
TERMITE SHIELD ~SlLL GASKET ~ ~~ +' ,
TYP. CONC, FOUNDATION ~ CONC. SLAB NEOPRENE '
GRANULAR FILL ...... ~ I BOLTED TO 5TEEL BEA~ BITH
6MIL POLY ON EXTERIOR ~ ~ STEEL COLUMN ' ~ ' ' ' ' ' ' ~'~ '/ ~ ' 112" D~A. ~OLT8 ~ 48" ¢.c, ~T~.
~/ 5 I > ~ ( ROOF JACK ~
~ ~/ 6TELL
KE~AY FOOTING ~ V ~7 ~ ~ , ~ ~, , ' ROOFING LAP ~ TOP ~ND eOTTOM PLATE
. , ANCHOR BOLT CONNECTION USE WITH 3x3 SQUARE WASHERS SIDES AND TO 1/2" G~OUT
DRAIN TILE ~ · 7 · ~ ~ J ANCHOR BOLT CONNECTION FOUNDATION 5/8" DIA, ANCHOR BOL' ~ ~" 5TELL COLUMN
SUPPORTING MAXIMUM SPACING FLASHING LAPS - -- ~ ~ ~ ~- ,
( IO ~IP5 )
{CRAWL SPACE OR FOUNDATION) 1 STORY 72" CC
TYPICAL CONC. FOUNDATION. APPLY PILASTERS SILL PLATE TO FOUNDATION T%PIC~L ~EAM DETAIL
WHERE NEEDED FOR STRUCTURAL BRACING. MIN. 3" STEEL COLUMN ANCHORED TO 24"x24"x12" CONC. FTG. (CRAWL SPACE OR FOUNDATION) 2 STORIES 36" CC 5TELL / BOTTOM EARIN
WALL BOTTOM PLATE TO FOUNDATION
{SLAB-ON-GRADE) 1-2 STORIES 57"OC OOF J OK6 ENT6 ET IL
OD.C, oo.
6X6 10/10~M ~A~E~ /// ~ ~J
COMPACT FILL ~~ ~00~ //// USE 2X8 0 - JOIST
FOR
BLOCKOUT
....... p.T. PLATE ~ - 6LO~E
· ,,
' ' ' ~ ' ' ' ' . .~5... 1/2"AIR S ~w~, 4 D~I~A~ NOTCH JOIST AND ADJUST HEIGHT
' - ' - ' ' ' ATENDAND , ,.~ . . ; - (WITH A NAILING PLATEIF NEEDED)
' ~> ~ ~' ~ ;' ~ ~ ~ ~'~~ ,~ ~ ~ NOTCH BEAM FOR MUDSILL IF REQUIRED -- MAXIMUM ~"-~ ' ~ ~ ~ 'd b ~ .'4 ~,~E
DRAIN TILE -~~~ ~ REINFORCING BAR . J ~,~ -REINFORCING BAR ~ , NOTCH EQUALS t/4 DEPTH OF BEAM )==~ ~ ~lll~m[~m~ Jo~sT
' OF CONTACT WITH CONCRETE or CONC. BLOCK ~~%L' ~ STEEL BEAM
(PICAL CONC. MONOLITHIC FOUNDATION. REINFORCE WITH (2) ~ REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. SHIMS TO LEVEL BEAM ~ ~ PLATE (BOLTED TO BEAM)
REINFORCE FOOTING WITH (2) ~ REINFORCING BARS, 3" MINIMUM BEARING SURFACE FOR WOOD BEAM ~E DOOR LOCKOUT
POCKET
FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION
INSTALL 4'0" C.C.
4" - 8" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS
ON ALL OPENINGS
INSTALL 4'0" O.C,
8"- t6" MSTA48 1-t/4"x48" 16ga. STRAP AND JACK STUDS
ON ALL OPENINGS
ENEf AL NOTE5
CONSTRUCTION NOTES:
1). The information within this set of construction documents is related to basic design
intent and framing details. They are intended as a construction aid, not a substitute
for generally accepted good building practice and compliance with current New York
State building codes. The General Contractor is responsible for providing standard
construction details and procedures to ensure a professionally finished, structurally
sound and a weatherproof completed product.
2). The General Contractor is responsible for ensuring that all work and construction
meets current federal, state, county and local codes, ordinances and regulations, etc.
These codes are to be considered as part of the specifications for this building and
should be adhered to even if in variance with the plan,
3). Dimensions shall take precedent over scaled drawings,
(DO NOT SCALE DRAWINGS).
4). The des gner has not been engaged for construction supervision and assumes no
responsibility for construction coordinating with these plans nor responsibility for
sonstruction means, methods, techniques, sequences, or procedures, or for safety
0recautions and programs in connection with the work. There are no warranties for a
specific use expressed or implied in the use of these plans.
5). Refer to the Window and Door schedule for exterior openings,
5). The General Contractor is to ensure that masonry or prefabracted fireplaces meets
exceeds manufactura's specifications and applicable codes.
7'), The General Contractor is to consult with the owner for all built-in items
such as bookcases, shelving, pantry, closets, trims, etc.
BI. Wind Icad requirements shall be taken into account during construction.
FOUNDATION NOTES:
1), The General Contractor and Mason to review plans, elevations, details and notes to
determine intended heights of finished floor(s) above typical grade.
2). Ail footings to rest on undisturbed (virgin) soil
3). Provide 1/2" expansion joint material between concrete slabs and abutting
:oncrate or masonry walls occuring in exterior or unheated interior areas.
4). Any new concrete walls being attached to existing concrete structure shall
0e installed with #5 re-bar, 18" long at 12" o,c., Use approved epoxy for installation.
5). Unless otherwise noted, all slabs on grade to be 2500 p.s.i,. Concrete to be
~oured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing. Interior slabs
lo be minimum 3-1/2 inch thick. Ail fill to be compacted to 95% relative density with
~" maximum lifts (layers).
Crawl spaces to be provided with a minimum 18"x24" access opening. Install one
cast iron foundation vent for every 150 sq. ft. of area.
7). Dampproof exterior of foundation with bituminous coating as per section R406 of
N.Y.S. Residential Construction Code. A 6-mil polyethylene film shall be applied over
the below grade portion of exterior walls prior to backfilling.
I. Drainage as per section R405 of N,Y.S. Residential Construction Code.
FRAMING NOTES
1), All framing techniques and methods as prescriptive design of 2006 SBC High Wind
Edition Wood Framing Construction Manual,
2). Unless otherwise noted, all framing and structural wood material to be #2 + BTR.
Douglas Fir.
3). Floors, walls, ceilings and rafters to be spaced at 16 inches c.c. unless noted
otherwise.
4). Unless otherwise noted, all bearing wall headers to be (2) 2x10 #2 + BTR. Doug, Fir.
Bearing wall headers to have (2) jack studs and (2) full length studs on each side of all
openings. LVL headers to have (3) jack studs and (2) full length studs on each side of
openings, Bearing wall window sills shall also have (2) window sill plates for 2x4 wall
openings between 4'1 and 6'0 and 2x6 wall openings between 5'11 and 8'9. Provide fire
and blocking where applicable.
5). All flush beams/headers to be installed with heavy duty galvinized hangers and
anchors where applicable to all connecting joists.
6), Double up floor joists under walls that run parallel to the floor joist and under bathtubs.
Floors to have ceramic tile installed shall be verified for proper Icad capacity unless noted
on plans.
7). Provide 2 - 1-3/4" thick micralams ( height to match floor joists) around stairwell and/or
other access openings unless otherwise noted (typical).
8). Dormers running up roof rafters are to be supported by double rafters on either side
where applicable unless otherwise noted.
9). Provide blocking/bridging in floor joists at 8'0 o,c., Use solid blocking in floor joists
under all bearing walls.
10). Provide insulation baffles at eave vents between rafters, Install draft blocking as
needed.
nless otherw se noted all roofs and walls to have a m n mum 1/2 th ck, 4-ply Fir
:erior sheathing grade plywood. Plywood to cover over plates and headers,
12). Unless otherwise noted use 3/4" thick T&G PTS Fir or Advantech plywood subfioor
adhered with PL400 adhesive and screwed to floor joists, Finished floor to be installed
over subfloor as per manufacture's instructions.
All bathroom walls to have 1/2" thick moisture-resistant sheetrock. Garage walls and
and over furnace tc have 5~8" thick type-x sheetrock. All other pads of building
to have regular 1/2" sheetrock, All walls to be taped and finished.
14). All reof with a pitch less than 4:12 shall be installed with an Ice & Water barrier or
approved equal. Flat roofs shall be applied with a Fiberglas base sheet with an EPDM
torch down type material over.
16). All sill plates and wood in contact with concrete to be pressure treated. Sill plates to
lbo nsta ed w th a foam s I gasket and cop-r-tax termite shield or approved equal.
WIND FRAMING NOTES
1). RIDGE-TO-RAFTER ASSEMBLY:
1-1/4" x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4.
When a collar tie is used in leu of a ridge strap, the number of 10d common nails required
in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap.
2). RAFTER-TO-WALL ASSEMBLY:
Lateral framing and shear wall connections for rafter, ceiling or truss to top plate shall be in
accordance to table 3.3. When a rafter or truss do not fall in line with studs below, rafters
or trusses shall be attached to the wall top plate and the wall top plate shall be attached to
the to the wall stud with uplift connections. Roofs overhanging the rake side of the building
shall be connected with uplift connections in accordance with table 3.3c.
3). WALL-TO-WALL ASSEMBLY:
Wall studs above and studs below a floor level shall be attached with uplift connections in
accordance with table 3.3b. When walt studs above do not fall in line with studs below, the
studs shall be attached to a common member in the floor assembly with uplift connectors Jn
accordance with table 3.3.
4). WALL ASSEMBLY TO FOUNDATION:
First wail studs shall be connected to the foundation, sill plate, or bottom plate with uplift
connectors. Steel straps shall have a minimum embedment of 7 inches in concrete
foundation and slab-on-grade, 15 inches in masonry block foundations, or lapped under
the plate and nailed in accordance with table 3.3b. When steel straps are lapped under the
bottom plate, 3 inch square washes shall be used with the anchor bolts. Anchor bolt
spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing,
anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all
corners.
5). TYPE I EXTERIOR SHEARWALL CONNECTIONS:
Type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior
attached with 8d common nails at 6" c.c. atthe panel edges and 12" c.c. in the field, and
1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7" c.c. at panel
edges and 10" c.c. in the field shall be in accordance with the length requirements specified
in table 3.t 5a-b.
6). TYPE II EXTERIOR SHEARWALL CONNECTIONS:
Type II exterior shearwalls shall meet the requirements of table 3.15a-b times the appropriate
length adjustment factors in table 3.f 6.
7). INTERIOR SHEARWALL CONNECTIONS:
Allowable sidewall lengths provided in table 3. t4 shall be permitted to be increased when
interior shearwalls are used. Sheathing and connections shall be in accordance with
2.4.4.2 and 2.2.4 respectively.
8), CONNECTIONS AROUND EXTERIOR WALL OPENINGS:
Header and/or girder connections shall be attached with uplift connections in accordance
with table 3.5. Window sill plates shall be have steel connectors in accordance with table
3.5.
9). CATHEDRAL CEILING ASSEMBLY:
Where a ridge is to be used as a structural beam, the rafters shall either be notched and
anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge
along the open ceiling part of the building. Connections, to the ridge and wall shall be be
attached with the above requirements.
DECK AND COVERED PORCH NOTES:
1). Unless otherwise noted, all framing material to be #1 ACQ pressure treated lumber.
All fasteners, hangers and anchors to be galvinized or stainless steel
2), Girders for deck joists to be bolted to each post with washers and nuts.
Girders on concrete piers shall be anchored with proper steel connectors anchored
into concrete with a minimum 1/2" dia x 7" long anchor bolt with washers and nuts,
3). Posts supporting girders shall be anchored to a 12"x12"x12" thick concrete footing.
Use a minimum 1/2" dia x 8" long anchor bolt with washers and nuts. Footings Shall be 3 fl,
below grede. Porches with covered roofs shall have 12" dia. concrete piers for the girders~
4). Deck joists to have blocking at 8'0 c.c..
5). A minimum of 10 inch flashing shall be installed between the building and ledger,
Ledger to be fastened to building with 1/2" dia. bolts with washers and nuts
where needed.
6). Concrete piers shall be a minimum 6" above grade.
7). All joists to be supported with hangers and anchors. Each Joist shall also be anchored
to girder(s).
8). Covered Roofs shall be assembled and anchored the same manner as a typical building.
PLUMBING NOTES
'1 ). All water supply, drainage and venting to be installed as per N.Y.S. Residential
Construction Code.
2). Verify septic system with the Engineer for Suffolk County Health Department approval,
3). If wall studs, plates or joists are cut out during installation for any plumbing related work,
provide adequate bracing and plates to protect and secure the structure. Verity with the
state code and manufacture's recommendation for ma~(imum hole size and spacing permitted.
HVAC SYSTEM NOTES
1). Mechanical subcontractor is responsible for adhearing to all applicable codes and safety
requirements,
2). HVAC subcontractor is to fully coordinate all systero data and requirements with the
equipment supplier,
3). HVAC subcontractor to provide final system layout drawing and submit it to the General
Contractor and owner for final review and approval.
ELECTRICAL NOTES:
1). Ali electrical to be installed as per N.Y,S. Residential Construction Code.
2). All electrical work shall be approved by a qualified Underwriter.
3). Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317
of N.Y.S. Residential Construction Code.
NAILING SCHEDULE
ROOF FRAMING:
NAIL NAIL
JOINT DESCRIPTION NOTES
QTY. SPACING
RAFTER TO 8' WALL: 3-6d COMMON: EACH
TOP PLATE 10' WALL: 4-8d COMMON RAFTER TOE-NAIL
GELLING JOIST 8' WALL: 3-8d COMMON EACH
TO TOP PLATE 10'WALL: 4-8d COMMON JOIST TOE-NAIL
CEILING JOIST TO AS PER TABLE 3.7 EACH FACE
PARALLEL RAFTER WFCM -SBC LAP NAIL
CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE
OVER PARTITION WFOM -SBC LAP NAIL
COLLAR TIE AS PER TABLE 3.4 EACH FACE
TO RAFTER WFCM -SBC END NAiL
BLOCKING 2 - 8d COMMON EACH TOE
TO RAFTER END NAIL
RIM BOARD EACH END
2 - 16d COMMON
TO RAFTER END NAIL
WALL FRAMING:
NAIL NAIL
JOINT DESCRIPTION NOTES
QTY. SPACING
TOP PLATE TO PER FACE NAIL
2 - 16d COMMON
TOP PLATE FOOT SEE NOTE: '1
TOP PLATES AT 4 - 16d COMMON JOINTS FACE
INTERSECTIONS LA, SIDE NAIL
STUD TO 2- 16d COMMON 24" FACE
STUD C.C. NAIL
HEADER TO 16" O.C. FACE
f6d COMMON
HEADER ALONG EDGES NAIL
TOP OR BOTTOM 2 - 16d COMMON PER 2x4 STUD END
PLATE TO STUD 3 - 16d COMMON PER 2x6 STUD NAIL
BOTTOM PLATE TO: PER FACE NAIL
FLOOR JOIST, BAND JOIST 2 - 16d COMMON
FOOT SEE NOTE: 1,2
END JOIST OR BLOCKING
FLOOR FRAMING:
NAIL NAIL NOTES
JOINT DESCRIPTION QTY, SPACING
JOIST TO: PER TOE
4 - 8d COMMON
SILL, TOP PLATE OR GIRDER JOIST NAIL
BRIDGING EACH TOE
2 - 8d COMMON
TO JOIST END NAIL
BLOCKING EACH TOE
2 - 8d COMMON
TO JOIST END NAIL
BLOCKING TO: 3- 16d COMMON EACH TOE
SILL OR TOP PLATE BLOCK NAIL
LEDGER STRIP EACH FACE
TO BEAM ~3- 16d COMMON JOIST NAIL
JOIST ON LEDGER PER TOE
TO BEAM 3 - 8d COMMON JOIST NAIL
BAND JOIST PER END
3 - 16d COMMON
TO JOIST JOIST NAIL
BAND JOIST TO: ,2 - 16d COMMON PER TOE NAIL
SILL OR TOP PLATE FOOT SEE NOTE: 1
ROOF SHEATHING:
BTRUCTURALPANELI Sd IASv A Ec3'81
CEILING SHEATHING:
JOINT DESCRIPTION
GYPSUM
WALLBOARD
NAIL NAIL
QTY. SPACING
7"~ O.C. EDGE
5dCOOLER'~ '10 O.C.FELD
WALL SHEATHING:
NAIL NAIL
JOINT DESCRIPTION QTY. SPACING
STRUCTURAL 8d COMMON AS PER TABLE 3.9
PANELS WFCM -SBC
7/16" OSB 3" C.C. EDGE
PLYWOOD 6d COMMON 6" O,C, FIELD
GYPSUM 7" C.C. EDGE
5d COOLERS
WALLBOARD '10" O.C. FIELD
FLOOR SHEATHING:
JOINT DESCRIPTION NAILQTy. II SPACINGNAIL
NOTES:
THESE NOTES ARE ONLY TO BE REFERRED TO IF
MENTIONED IN SCHEDULE NOTES ONLY.
1). Nailing requirements are based on wall sheathing
nailed 6" on-center at the panel edge. If wall sheathing
is nailed 3" on-center at the panel edge to obtain higher
shear capacities, nailing requirements for structural
members shall be doubled, or alternate connectors,
such as shear plates, shall be used to maintain Icad path.
2). When wall sheathing is continuous over connected
members,the tabulated number of nails shall be permitted
to be reduced to1 - 16d nail per foot.
PL,AN CONTENTE.
OCCUPANCY CLA~51FICATION I~3 f~E$1DENTIAL
E~iJILDING USE f~EblDENTIAL DLUELLING
E~UlLDING HEIGHT (SEE
TOTAL 5~. FT. OF CONSTRUCTION (SEE ~L~N~)
P~E~CRIPTIVE ~5 PER N.T.~. RESIDENTIAL CONSTRUCTION CODE
~ESIGN CRITERIA
2OO~ ~C Ni~H ~IND E~ITION, ~OOD F~E CON~T~UCTrON ~ANUAL
F~A~IN~ ELEMENT5 A5 PER FLOOR PLANS, 0~0~5 5LOTION ~N~ GENERAL NOTE5
EXT. ~ALCONIE~ ~O
~TTIC~ ~/~ ~TOR~GE
~TTIC5 ~/ 5TO~E 20
DESIGN LOA~ C~LCBL~TION5 ROOF (~OBND ~NO~ LOADJ 20
(LI~E LOAD5 P~F)
~00~ (OTHE~ THAN bLEEPING) 40
ROO~ (SLEEPING) 50
~U~D~AIL5 (ANT ~I~ECTION) 200
EXPOSURE C~T~GO~Y (~ESI~NED FO~ CAT.
LO~D P~TN SEE CONSTRUCTION ~NDBIND PATH CONNECTION
(~OOF - FOUNdaTION) DETAIL PAGE ~ GENERAL NOTE PAGE
NAILfN~ ~CNE~ULE ~EE GENERAL NOTE
EGRESS 5EL FLOO~ PL~N~ AND ~NDO~ ~CNEDULE
FI~E P~OTECTION ~m.:
(5~OKE ~ CO2 DETECTORbJ ~ 5EL FLOOR
T~U55 DESIGN N/A - 5TANKARD 5TIC~ F~A~E CONSTRUCTION
ENERGY O~LCUL~TION5 ~E~CNEC~
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA
GROUND WIND SEISMIC FROST WINTER ICESHIELD
SNOW SPEED DESIGN INEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT FLOOD
HAZARDS
LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED
20 LBS. t20 B SEVERE 3 FT. MODERATE SLIGHTTO tl NONE
TO HEAVY MODERATE
ROOFSHEATHING REQUIREMENTS FOR WIND LOADS:
NAIL SPACING NAIL SPACING AT INTERMEDIATE
SHEATHING LOCATION AT PANEL EDGES SUPPORTS iN THE PANEL FIELD NOTES
4' PERIMETER EDGE ZONE 5d COMMON @ 6" O,C. 8d COMMON @ 6" O,C. SEE NOTES: '1,3
INTERIOR ZONE 8d COMMON @ 6" C.C. 8d COMMON @ 12" O,C. SEE NOTES: '1 ( BOTH FI
NOTE: 2 FOR PANEL FI
GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4" O.C, 8d COMMON @ 4" C.C. SEE NOTES: '1,3
NOTES
THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
1). For roof sheatlhing within 4 feet of the perimeter edge of the roof, including 4 feet on each side of the roof peak,
the 4 foot perimeter edge zone attachments required shall be used.
2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to rafter / truss framing members with G>0.49.
For framing members with <0.42<G<0,49, the nail spacing shall be reduced to 6 inches c.c.
3). Tabulated 4 inch o,c. nail spacing assumes sheathing to rafter / truss framing members with G>0,49. For
framing members with 0.42<G<0.49, the nail spacing shall be reduced to 3 inches o.c,
WALL SHEATHING REQUIREMENTS FOR WIND LOADS:
NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES
SHEATHING LOCATION AT PANEL EDGES SUPPORTS iN THE PANEL FIELD
SEE NOTES: t, 3 ( BOTH FIELDS
4' EDGE ZONE 8d COMMON @ 6" C.C. 8d COMMON @ 12" O,C.
NOTE: 2 FOR PANEL FIELD
INTERIOR ZONE 8d COMMON @ 6" C.C. 8d COMMON @ 12" O,C. SEE NOTE: 3
NOTES
THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY.
1). For wall sheathing within 4 feet of the corners, the 4 foot edge zone attachment requirements shall
be used.
2). Tabulated 12 inch c.c. nail spacing assumes sheathing attached to stud framing members with
G>0,49. For framing members with 0.42<G<, the nail spacings shall be reduced to 6 inches o.c,
3). For exterior panel siding, galvinized box nails shall be permitted to be substituted for common nails.
NOTE:
CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY
EXISTING CONDITIONS. MINIMUM 3000# CAPACITY,
1 ), PROVIDE 5/8" TYPE-X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS.
2). USE SIMPSON HANGERS AND ANCHORS WITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ.
3). INSTALL 1 - Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR.
~ectfon R~O2.~, - FIREtBLOCKING I~EQLJIF~ED
Flreblockfn~ shall be provided to cut orr all concealed draft openings (both vertical and horizontal)
and to Form an effective Fire barrier bef. uJeen stories, and between a top s~or~ and ~he roof space.
Fir~blockln~ shall be provided In mood-Frame construction In the Fotlomln~ Iocationa.
I).
In conceaIed spaces of stud malls and partIWone, lnoludTn~ Furred spaces, at the ceilln~ and Floor
levels. Concealed horizontal Furred spaces shall also be ?Ireblocked at Intervals not
usln~ ~arall~l roms o¢ studs or s%a~r~d studs.
drop ceilings and cove ceilings,r.,~
3). In concealed spaces bell.Neon stair etrln~ers at the top and bottom of the run. Enclosed spaces
under stairs shall comply Lulth 5action ~314,~, N.¥,5. f~esldentia[ Code,
4), At openings around vents, plpes and ducts at cellln~ and Floor level, to resist the Free passac~e of
Flame anc~ products of combustion.
For the Fireblockln~ of chlmneqs and Fireplaces, refer to Section RIOOl.l&. N.~.~. ~esldentlal Code.