HomeMy WebLinkAbout25261-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-33882
Date: 08/05/09
THIS CERTIFIES that the building ACCESSORY GARAGE
Location of Property: 520 CEDAR DR
(HOUSE NO.)
Cou~t¥ Taxi, ap No. 473889 Section 106
subdivision
MATTITUCK
(STREET) (HAMLET)
Block 10 Lot 24.1
Filed Map No. Lot No. __
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JUNE 9, 1998 pursuant to which
Building Permit No. 25261-Z dated OCTOBER 21, 1998
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ACCESSORY TWO CAR GARAGE AS APPLIED FOR PER ZBA ~4608 DATED 10/15/98.
The certificate is issued to DANIELLE GRZEGORCZYK
(OWNER)
of the aforesaid building.
SIIFFOLK COUNtrY DRP~T~T OF }~ALTH ~PPRO~
ELRt-£KICAL C~TIFICATH NO.
PLiErS CERTIFICATION DA'r~D
N/A
N/A
Rev. 1/81
Form No. 6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properiY completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy- $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction:
Location of Property: ~ 2 CD
House No.
Owner or Owners of Property:
Suffolk County Tax Map No 1000, Section \
Subdivision f)~-~l I_ !
Permit No. ~ Date of Permit.
Health Dept. Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $ q~ ~
Date.
Old or Pre-existing Building:
Street
Block
Filed Map.
(check one)
Hamlet
Lot ~[[~. I
Lot:
Applicant:
Final Certificate:
(check one)
Applicant Signature
Underwriters Approval:
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 25261 Z
Date OCTOBER 21~ 1998
Permission is hereby granted to:
for :
BERYLE E CAFFREY
9395 SOUND AVENUE
MATTITUCK~NY 11952
CONSTRUCT AN ACCESSORY STORAGE GARAGE IN THE FRONT YD.
OF A SINGLE
FAMILY DWELLING AS PER ZBA APPEAL#4608~ 10/15/98.
at premises located at 520 CEDAR DR
County Tax Map No. 473889 Section 106
pursuant to application dated JUNE
Building Inspector.
MATTITUCK
Block 0010 Lot No. 024.001
9 1998 and approved by the
Fee $ 47.80
ORIGINAL
Rev. 2/19/98
APPEALS BOARD MEMBERS
Gerard P. Goehringer, Chairman
James Dinizio, Jr.
Lydia A. Tortora
Lora S. Collins
George Homing
BOARD OF APPEALS
TOWN OF SOUTHOLD
Southold Town Hall
53095 Main Road
P.O. Box 1179
Southold, New York 11971
ZBA Fax (516) 765-9064
TeI~p~e (516) 765-1809
FINDINGS, DELIBERATIONS AND DETERMINATION
REGULAR MEETING OF OCTOBER 15, 1998
Appl. NO. 4608 - BERYL E. CAFFREY PARCEL 1000-106-10-24.1
STREET & LOCALITY: 520 Cedar Drive, Mattituck
DATE OF PUBLIC HEARING: October 15, 1998
FINDINGS OF FACT
PROPERTY FACTS/DESCRIPTION: The subject property fronts along the west side of
Cedar Drive and the north side of Millers Right-of-Way, Mattituck, with a total area of
43,560+- sq. ft. The property is improved with a one-story frame dwelling. The
accessory garage shown on the survey submitted with this application is planned to be
removed (if it has not already been removed by the date of this action.)
BASIS OF APPLICATION: Building Inspector's August 12, 1998 Notice of Disapproval
under Article IIIA, Section 100-30A.4 for the proposed location of a new accessory garage
and accessory storage shed in a front yard area.
AREA VARIANCE RELIEF REQUESTED: Applicant is requesting a variance to locate
two accessory buildings which are: (a) 24 ft. by 24 ft. and (b) 8ft. by 10 ft. The
setbacks are to be at least 20 feet from the side property line at its closest point and at
least 100 feet from the front property line along Hillers Right-of-Way to meet code.
REASONS FOR BOARD ACTION, DESCRIBED BELOW:
(1) The granting of the area variance will not produce an undesirable
change in the character of neighborhood or a detriment to nearby properties because the
garage and shed will be built well within the setback limits of the code requirement for a
principle structure.
Page~2 ---October 15, 1998
Southokl Town Board of Appeals
Re: Caffrey 1000-106-10-24.1
(2) The benefit sought by the applicant cannot be achieved by some method,
feasible for applicant to pursue, other than an area variance because the applicant has
two front yards according to Southold Town law.
(3) The requested area variance is not substantial in that the applicant has a
lot in excess of 40,000 sq. ft. and is removing a shed that is built over the property line
and a garage with a non-conforming setback from the side yard.
(4) There is no evidence that the grant of the variance will have an adverse
effect or impact on the physical or environmental conditions in the neighborhood or
district.
(5) The alleged difficulty has not been self-created.
~n considering this application, the Board deems this action to be the minimum necessary
and adequate to preserve and protect the character of the neighborhood, and the health,
safety, welfare of the community.
RESOLU'F[ON/ACT~ON: On motion by Member Dinizio, seconded by Chairman
Goehringer, it was
RESOLVED, to GRANT the variance, as applied for.
VOTE OF THE BOARD: AYES: MEMBERS GOEHRINGER, DINIZIO, TORTORA, COLLINS,
HORNING. This Resolution was duly adopted (5-0)~.~---) ~-
//GERARD P. GOEHRINGE~ - /
/./ CHAIRMAN 10/15/98 ~
f Approved for Filing
/d Jo -/~: o/~ -.~¢./TO~NI~' OF SOUTHOLD PROPERTY RECORD CARD
)WNER STREET ~"~ ~ VILLAGE 'DIST ~ ---W' ~'~' o~ /~
S W ~PE OF BUILDING
~'~O S~S. ~ FA~ COMM. CB. MISC. Mkt. Value
~ND IMP. TOTALDATE RE~RKS
~o ~o~ ~/oo ~ Vh/~~/~/~/7~ ~,~ (~,,)~,.~ - ~ ~ ~ ~. e~r~,~ ~r ~-~,
AGE BUILDING CONDITION / I I ~ .I " /
4~ NOeL BELOW ABOVE
ARM Acre Value Per Value
~re
Ileble
Ileble 2
leble 3
~lend
emp~nd FRONTAGE ON WATER
,shland FRONTAGE ON ROAD //3 ' ~ ~1 ' : ~ ~
,use Plot DEPTH /(O '
BULKH~D
tal ~ ~ DOCK
tension
tension
irch
'eezeway
irc~e
3rio
?
I I I I r I 13,,~, '
Foundation
Basement
Ext. Walls
Fire Piece
Type Roof
Recreation Roorr
Dormer
Driveway
Bath / Dinette
Floors ¢~/,~/~ K.
Interior Finish
Heat
Rooms 1st Floor
Rooms 2nd Floo~
DR.
BR.
FIN. 8.
OWNER
--
FORMER OWNER
LAND
/80o
TOWN OF SOUTHOLD
/
STREET
:ES. 3 1 2-- SEAS.
IMP.
AGE
NEW NORMAL
Acre
PROPERTY RECORD CARD
FL.
FARM
TOTAL
DATE
BUILDING CONDITION
VILLAGE
coM.
R~RKS
LOT
4eadowland DEPTH
~ouse Plot BULKHEAD
rotal DOCK
FAPJ~ Value Per Value
Acre
Fillable FRONTAGE ON WATER
~oodland FRONTAGE ON ROAD
BELOW ABOVE
DIST.I SUB.
ACE. ¢ o~,~-e ;.,-c I.'"
~P[ OF BUILDING
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ].~UJ. ATION
[ ] FRAMING [ ~ FINAL
[ ] FIREPLACE & CHIMNEY
REMARKS:
DATE
INSPECTOR
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION2ND [ ] INSULATION
[ ] FRAMING [ ] FINAL
[]FIREPLACE&CHIMNEY
DATE
INSPECTOR
:OUNDATION (1st)
~OUNDATION
(2nd)
ROUGH FRAME &
.PLUMBING
INSULATION PER N.
STATE ENERGY
CODE
FINAL
ADDITIONAL COMNENTS:
BLDG. DEPT.
TOWN Or spcrm0Lo
FORM NO. 1
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, N.Y. 11971
BOARD OF HEALTH .........
3 SETS OF PLANS ..........
SURVEY ...................
CIIECK ....................
SEPTIC FORH ..............
TEL.: 765-1803
, . . .
· ........
CALL .......
~A~L TO: 7~-t4(y~
INSTRUCTIONS
a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3
sets of plans, accurate plot plan to scale· Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets
or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli-
cation.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy
shall have been granted by the Building Inspector·
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
P, uilding Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, ,as herein described.
The applicant agrees to comply with all applicable laws, ordinances, building 9ode, housing,,c~ode~a,~t regulations, and to
admit authorized inspectors on premises and in building for necessary..~~~;::~ . ..---- ' '~~~
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician~ plumber or builder.
:.
Name of owner of premises (as on ....... the tax ;Jl{ ;; iit~'~~~? ~
If applicant is a corporation, signature of duly authorized officer· ~l~f~~
(Name and title of corporate officer) ~
Builder'] License No I ~ ~7g -/4~
Plumber s License N~.' . i i ,~,' '/~ i O~'~l,J ~A"C' O"
Electrician's License No .... ~ (~ US[. !S UNLAWFUL
.. ~"' WITHOUT CERTIFICATE
Oth~W.d~'~ Li~.s~ No. .~ .......... ~ OCCUPANCY
FOI. LOVlRI~ ~
1. EOUWO~I~ON - 1WO RI!OUIII~
FOR FOU~D~
3. INSU~
4. FINAL - CON~U~ON MU~
BE COM~t ~
ALL CONSTRUCTION SHALL MEET
THE REQUIREMENTS OF THE N.Y.
1. Location of land on which proposed work will be done ................... '. ............. U...'. i,: .'... ~':
· ................... ...................... ................
House Number Street Hamlet
County Tax Map No. 1000 Se~)7~.. ~...~ .......... Block ...... 'i?~./~i' Lot...~.~:.[../~./A .........
Subdivision .............. ~a~) ................ Filed Map No .... Lot.. ~ .......
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy..~.~...~..~,~a/h~.-.~'.. .................................................
b. Intended use and occupancy ~~ ] ]'~. ] .~<~.'ZZ...'..'~. ......................................
3. Nature of work (check which applicable): New Building ...... Addition ........ i k~Alteratidn ..........
Repair .............. Removal .............. Demolition .............. Ot ,l~er Work, ...............
'~ (D ripti0 )
· ·. ' i ~ - est n
4. Estimated Cost a~.b~
· · ............... Fee .........
- ! (to be paid on f'fling this application)
5. If dwelling, number of dwelling units../X J/.~. ........ Number of dwelling units on each floor ................
· Ifil garage,business,nUmbercommercialOf cars ...'~.V,J~. ............................................ .t ~:/~-i ................
6.
or mixed occupancy, specify nature and extent of each type of use . f?//f.3c. .............
7. Dimensions. o~e~xi?ting structures, if any'. Front .~-~'.. ~........r Rear .......~Yg tr. -~r~,~th... ~ ' .~ t~ ' · ·
H.e~ght .....//:~ ........ Number of Stories .../~./N/J~.- ............................. ~ .............
~Dtm.e, ns, on~o~/~me s.tmcture with alteration~ o~a~l¢~tions: Front ... _- _~/~ Rear iD1~ ............
ueprn 't~, Hei t ............
.... ~{t-r... ............ gh ././.~/t/~> .~.~ .......... Number of Stones .... ~//'JT~/-i., .........
~. ~menmonsp} e.nure new construction: Front f;.a/., .... Rear ~-~.{ ' Denth' .,~./-/
Height ../.~.'. ........ Number of Stories .... ..~k~ ~- ' .............. ~ ................
9. Size of lot: Front ~ //~ ~.~ ' "~fJ i '1" '/~) i 't ....... ~," :," ~" ~_z'~'~ .........
10 Da .... ""&'& f.2~X, ...................... t~.q ....... saeprn .~;=r:wT....,-,.~.., ..........
1 I' -- [e Ol rurcn~a~e :...r~.. '~' ~.. A c.~ ..... ....... ~Name of Former Owner .~4:YM,~.. fi,..~/:~.~ ......
· ~one or use nistrict in wnicn premises are situated.. ~.?.~x~ ..........................................
12. Does proposed construction violate any zoning law, ordinance or regulation: . ./~. ...................... ~.~
13. Will lot be regraded .. 1/~) ....................... Will excass.fill be remolted from premises: _.._Ye~ ff No)
14. ,N, ame of Owner ofpremises~.,~.. Address ~.~~. Phone No ~q~
mame of Architect .Afta~ Addre~. A ML ' ' ,,~ ,, ' ...............
................. ~a ............... rnone wo ...............
N?.of Contractor hl . 5 ....... Address .' .... Phon No.
15. xs this property within 300 feet of a tidal wetland? *Yes .. . u~ 5/ ..........
· If yes, Southold Town Trustees Permit ma be re uirifi ....... I'W .....
Y q ·
PLOT DIAGRAM
Locate clearly and distinctly all buildings, whether existing or proposed, and. indicate all set-back dimensions from
property lines. Give street and block number or description according to deed, and show street names and indicate whether
interior or corner lot.
s.s g.
...... ~ ] ·''"' ~" '~' '~'~' - .. - · - · .~......' being duly sworn, deposes and says that he is the applicant
(Name of individual signing contract)
above named. .
He
is
the
of said owner or owne~, ~d is duly auto.ed to perfo~have~ peffo~ed the said work ~d to m~e ~d file ~is
application; that all statements cont~ned ~ ~is application are true to the best of his ~owledge and belief; and that the
work will be perfo~ed in the m~ner set fo~ ~ the application filed therewith·
Sworn to before me this
.............. ; ......... day of..~~ ........ , 19 .~.~
. ..............
Ouslified in Suffolk qounW
Commisaion Expires May 22, ~9 /,~ - .
D~V~WA¥
121
,/
/
o~ o'~
/
MILLERS RIGHT OF WAY
~OP~ HO. 3
TO~INOF SOu~uOLD
BUILDING DEPARTMENT
SO~ruOLD, N.Y.
NOTICE OF DISAPPROVAL
To
22355 Cox Lane
Cutchogue, NY 11935
PLEASE TAXE NOTICE that your application dated Jppe 9,. . 98
520 Cedar Drive Nattituck
Location of Property ..........................
House No. Street Hamlet
County'Tax Hap No. 1000 - Section .1~. ....... BLOCK 10 LOT2~:I
Subdivision ......................... -- -. · . Filed Hap No .......... Lot Ho ........
is returned herewith and disapproved on the following grounds 0u0~r..4~gi~l~.l!!~ ....
Section 100-30A.4 of the R40 Zone accessory structures an? buildings must be
located in the required rear yard. -._
Note- Property owner said she plans to remove the existing garage and
BUILDING INSPECTOR'
RV 1/80
MORTON' BUILDINGS GENERAL SPECIFICATIONS
~ - NO 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 5 MEMBER S4S
COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8
POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE Ill, OXIDE TYPE, AS LISTED IN
FEDERAL SPECIFICATION TT-W-571d. THE TREATED PORTION OF THE COLUMN EMBEDDED IN GROUND
SHALL BE LAMINATED WITH STAINLESS STEEL NAILS.
FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG 4 FEET DEEP MIN. DEPTH BELOW GRADE AND
READY-MIX CONCRETE PADS OR DRY CONCRETE MIX PADS ARE POURED IN PLACE (NOTE PLANS FOR
SIZE & TYPE). TWO GALVANIZED STEEL BASE ANCHORS ARE PLACED 1" FROM BOTTOM OF COLUMN
OR 1/2" GALVANIZED STEEL ROD PLACED 2 1/2" FROM BOTTOM OF COLUMN.( SEE SECTION )ADDITIONAL CONCRETE
IS MIX POURED AROUND BASE OF COLUMN THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS
SPLASHBOARDS - SPLASHBOARDS ARE NO. 2 OR BETTER SOUTHERN YELLOW PINE 2"x8" S2S AND CENTER
MATCHED, PRESSURE TREATED TO NET RETENTION OF .6 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER
ARSENATE TYPE III, OXIDE TYPE, IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS' ASSOCIATION SPECIFICATION
C2 ONE ROW IS FURNISHED FOR BUILDING ON A LEVEL SITE
~ -SIDE NAILERS ARE 2"x4" SAS OR 2"×8" SPF NO.2 OR BETTER SPACED APPROXIMATELY 30" O.C
WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS, ROOF PURLINS ARE 2"x4" SAS NO, 2 OR
BETTER ON EDGE SPACED APPROXIMATELY 24" O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER ( SEE SECTION
ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS
REQUIRED AND KILN DRIED LUMBER AS SPECIFIED. IN-PLANT QUALITY CONTROL INSPECTION IS CONDUCTED
UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU, TRUSSES ABE DESIGNEE IN ACCORDANCE WITH
CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING.
$!_DING PANELS ~KYNAR 500/HYLAB 5000') -0.019" MIN., 690 GALVANIZED OR AZB5
GALVALUME, WITH AN ADDITIONAL BAKED-ON KYNAR
NOM. 1 MIL THICK ON EXTERIOR
ROOFING PANELS (KYNAR 500/HYLAR 5000') -0019"
500/RYLAR 5000 FINISH, PAINT
MIN, G@O GALVANIZED OR AZ55
GALVALUME, WITH AN ADDITrONAL BAKED-ON KYNAR 500/HYLAR 5000 FINISH. PAINT IS
NOM. 1 MIL THICK ON EXTERIOR.
TRIM -DiE-FORMED TRIM OF 0.019" MIN., 690 GALVANIZED OR AZ55 GALVALUME STEEL
ON GABLES, RIDGES, CORNERS, BASE, WINDOWS, AND DOORS WITH SAME FINISH AS
ROOFING OR SIDING PANELS.
GUTTERS - 5" K-STYLE, 030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500/HYLAR 5000
FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDINO
ADDITIONAL NOTES
1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED AS PART
OF THESE DRAWINGS.
2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WiTH THESE DRAWINGS SHALL BE PROMDED
BY OWNER. STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY
ASTM ED4 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, AND CORRIDORS.
3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING PROCEDURES
AS REQUIRED FOR WALL AND CEILING FINISHES.
4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECIFIC
JOB DRAWINGS OR SUPPLEMENTAL INFORMATION.
5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ELF ATOCBEM NORTH AMERICA, HYLAR
5000 IS A TRADEMARK OF AUSIMONT, USA.
CS2x4KK 2-96
TYPICAL LUMBER SPECIFICATIONS- 1991 NDS
SIZE DESCRIPTION FENDING VALUE Fb
2"x4" NO.1&2 SPF 1313 PSI
2"x4" 2100f MSR SPF 2100 PSi
2"x6" NOA&:2 SPF 1138 PSI
2"x6" ND. 1 SYP 1650 PSI
2"x8" NO. 1 SYP 1500 PSI
2"x10" NO. 1 SYP 1300 PSi
2"x12" NO. 1 SYP 1250 PSI
ALL 1950f MSR SYP 1950 PSI
1 1/2"x16" LAMINATED VENEER LUMBER 2800 PSI
5 1/2"x15" GLU-LAM 1650 PSI
1/4'xl6 ~/2" GLU-LAM 2400
5 1/4"x19 1/2" GLU-LAM 2400 PSI
NOTE: HIOHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS.
SHEET INDEX
SHEET # DESCRIPTION
1 OF 3SPECIFICATIONS & SHEET INDEX
2 OF 3COLUMN PLAN & ELEVATIONS
3 OF ,5 SECTIONS, DETAIL &: TRUSS DRAWING
I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR
THIS BUILDING WAS PREPARED BY ME OR UNDER MY
PROFESSIONAL ENGINEER. Id C."-g J
RONALD L. SUTTON, P,E
MICHAEL L. McCORMICK P.E.
DATF./I-4-~"V RED. # ' S"]qi cf
· FOFFiCE II~
DATE; 10-98-97
CHECKED BY: MI]('~ M,
REVISED DATE:
REVISED DATE:
REVISED DATE:
EV,SED D*TE: i
BCALE:8.EET NO.=----"
1 oF
SHINGLES
OG. GUTTERS
ELEVATION
GLES
5" 0 O GUTTERS
GU 0 ~
LEVAT~ON
11'-10 1/2" 19'-4 J/2"
7'-6' T-§"
1'-0" OVERHANG (SIDES VENTED)
O0 LU B N
& 150
~ V~NYL SIDING
F- .,/%.
12
-- T#144,146 & 150
VINYL SIDING
WL~T
E
Y
PLAN
LE-G E N D
o- 3-2x6 LAMINATED COLUMN LOCATION
(~- 18'xT OVERHEAD DOOR W/OPERATOR &: REMOTE
[]- 3068 9-LITE T-300 WALK DOOR
CUTCHOGUE, NY
JOB NO.
m
Z
m
BY: MBH
DATE: 10-28-97
CHECKED
DATE:
REVISED DATE:
REVISED DARE:
REVISED DATE:
REVISED DATE:
=i'-O",O,~ ]
I/2" CDX PLYWOOD &
(I) LAYER ROOFING FELT
2x4 PURLINS @ 16" O.C--
(NO 2 SPF)
2x4 BEV
T#150 DRIP EDGE
2×6 BEV FASCIA
5" O.D. GUTTERS
T#144 & 146 FASCIA TRIM
24' S.C TRUSS
HI-RIB/SOFFIT
2xB OVERHANG NAILER
1/2"x5 1/2" M. BOLTS &
(4) 20d R S NAILS
GRADE TO HEEL
2x4 VERTICAL CLOCKS @ 24" 0 C
-3-2x6 LAMINATED COLUMN
--2x4 NAILERS @ 32" O.C. 2100f MSR SPF
VINYL LAP SIDING
7/16" OBB & BUILDING WRAP
~'-- FINISH GRADE
SIDEWA L S
ROW 2xB TREATED SPLASHBOARD
CONCRETE FLOOR
4" MINIMUM COMPACTED GRANULAR BASE
(BY OWNER)
CONCRETE FLOOR NOTES
/
46M CASE ANCHORS
6" THICK READI-MIX PAD OR
(2)50# BAGS OF SACKRETE. PLACE
(1)50# BAG OF SACKRETE AROUND
COLUMNS WHEN SETTING.
NOTE.
CORNER AND ENDWALL COLUMNS WILL
HAVE 15" DIA. HOLES W/4" THICK READI-
MIX PADS OR (1)50# BAG OF SACKRETE.
PLACE (1)50# BAG OF SACKRETE AROUND
COLUMNS ~frlEN SETTING.
ECT ON A A
CO M.R.H. WIND LOAD
SCALE' I/2"= 1'-0"
TRUSS SPACING 7'-6" O.C.
UVE LOAD 30 PSF
DEAD LOAD ? PSF
CCILING LOAD - PSF
TOTAL LOAD 37 PSF
TRUSS DESIGN SPECIFICATION.
Truss has been designed by computer using the Purdue
Plone Structure Anolyzer lAW current stondords end
specificetio~s of recogmzed engineering principles.
Output dote will be provided upon requesL
LUMBER SPECIFICATION (1991 NDS for Wood Construction):
Lower Chord -- No. 1 K.D. - 19 Southern Pine
Top Chord --- No. 1 K.D. - 19 Southern Pine
Web Members -- No 1 K D. - 19 Southern Pine
TRUSS PLATE SPECIFICATION (ICBO Evoluotion Report No 2929):
ASTM A-446, Grode A 20 Go. end 18 De. where noted,
golvomzed steel Morton truss plotes identified by o
hexogon stomped every 1-1/4" olong the center of the plote
RAFTER LENGTH 13'3-$/16" Webs ore 2x4's
UPRIGHT
2x6 NAILER --
2x6 BLOCK
2x2 CLOCK
T# 151
T# 154
2x3 JAMB (BEYOND)
(3) 2xB JAMB COLUMN (BEYOND)
2x6 BLOCK (BEYOND)
O.H.D. HEADER
HEADER
HEADER
O.
UMASEAL
152
SECTION B
SCALE: 1 "= 1'-0"
CONCRETE FLOOR
2"x5" JAMB
JAMB COLUMN (BEYOND)
CONCRETE APPROACH
NO BCAL~E
9xll
Pt,
Web:~ i
4x5 12
PL. 6
Web~ 2
7'2-3/4"
CAMBER
13x8 Pt,
18 Go, 5x9 Pt,
LC .-
AT CENTERLINE 3~9~
1/2"
2xBx12'
11'10-1/2~
2 -'1 tS. C. TR L J
SCALE' 1/2'= 1' 0"
B
SLOPE GRADE AWAY FROM
APPROACH ~ 2% MINIMUM
FOR A DISTANCE OF 5'-0"
~4 REBAR CONT
AROUND PERIMETER
DETAIL
16x8 Pt, 18
15×5 PL,
CUTCHOGU ~, NY
JOB NO.
L- J
"DRAWN BY: MBH
DATE: 10-,88-97
CHECKED BY:
DATE:
REVISED DATE:
REVISED DATE:
REVISED DATE:
~EVISED DATE:
15-1/2"
L 3o[ 3
)