34668-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33723 Rte: 06/02/09 q%qIS CERTIFIES that the building DECK WITH HOT TUB ~cation of Prc~erty: 265 JASMINE LA SOUTHOLD (HOUSE NO.) (STREET) (HANLET) County Tax ~ap NO. 473889 Section 70 Block 1 I~t 6.2 Subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 30, 2009 pursu~q/lt to which Building Pezl~it No. 34668-Z dated M2~Y 11, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is "AS BUILT" DECK ADDITION WITH HOT TUB TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JOSEPH F & CAROL A BEST (OWNER) of the aforesaid building. BUF~DLK COL~FI~fDEPAR~TOF ~L/~4APPROVAL N/A EL~C~RICAL CERTIFIC3%TE NO. 4029379 05/22/09 PL[~BERS ~RTIFICR%TION DA'r~ N/A Rev. 1/81 TOW l_U, r mLO ¢ D P m NT 765-1802, . ' ] ~ BLDG DEP~ APPLICATION FOR CERT~ICATE OF OCCUPY IOWN OF ~OUT~OLD application m~t ~ fill~ in by ~wdter or ~ ~d sub~ to ~e Buil~ng Dep~em wi~ ~e follow.g: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Apprnval o f electrical installatien from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Plarming Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to iuspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Oceupancy - New dwelLing $25.00, Additions to dwelllng $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory buildihg $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporm-y Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Location of Property: 2(o~- House No. Street Owner or Owners of Property: ~-C~5~_p~ ~_ Suffolk County Tax Map No 1000, Section F/O Old or Pre-existing Building: (check one) Hamlet Block ol & 2 Subdivision Pe=it No. 3 g Health Dept. Approval: Planning Board Approval: DateofPermit.~]l[ I~ Filed Map.. Applicant: Underwriters Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ .~ppli~ign;ture FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL COMPLETION OF THE WORK AUTHORIZED) FULL PERMIT NO. 34668 Z Date MAY 11, 2009 Permission is hereby granted to: for : "AS BUILT" JOSEPH F & CAROL A BEST 265 JASMINE LA SOUTHOLD,NY 11971 DECK ADDITION TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 265 JASMINE LA SOUTHOLD County Tax Map No. 473889 Section 070 Block 0001 Lot No. 006.002 pursuant to application dated APRIL 30, 2009 and approved by the Building Inspector to expire on NOVEMBER 11, 2010. Fee $ 400.00 Authorized Signature ORIGINAL Rev. 5/8/02 BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by CAROL BEST CAROL BEST 265 JASMINE LANE 265 JASMINE LANE SOUTHOLD NY 11971 SOUTHOLD, NY 11971 Located at 265 JASMINE LANE SOUTHOLD, NY 11971 Application Number: 4029379 Certificate Number: 4029379 Section: 1000-70 Block: 01 Lot: 6,2 Building Permit: 34668Z BDC: ns11 Described as a Residential occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith onthe2z"d Day of Ma~,,Z009. Name QTY Rate Rating Circuits Tyne Miscellaneous supply power and disconnect to self contained hol tub Wiring And Devices Disconnect 1 0 31-100 amp seal 1 or I This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [ ] INSU~AZION [ ~.,.],,i~AL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS:~,/~/-~//~ ~,~/~-- DATE INSPECTOR ~'~~ James Deerkoski PE. 260 Deer Drive Mattituck, NY. 11952 631-298 -7116 To: Town of Southold Building Department Reference: Joseph and Carol Best 265 Jasmine Lane, Southold Building Permit # 34668-Z SCTM # 100-70-01-6.2 To Whom it may Concern, The following existing deck and footings located at, 265 Jasmine Lane, c~0xrm to New York State Code. James DeerkOsl~PE. FW.l,r~ INSPECTION REPORT I DATE I COMMENTS FOUNDATION (1ST) FO~ATION (2ND) ROUGH F~G & PL~G ~SULATION PER N. Y. STATE ENERGY CODE ~DITION~ COMMENTS TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY H971 TEL: (631) 7d511802 FAX-: (631) 765-9502 SoutholdTown. NorthFork. net Examined Approved Disapproved a/c el//,2°0¢ >ltt'2°C PERMIT NO. Expiration ~]I I I ,20[0 APR 3 0 999 8LDG. DEPI. · T0WNOF~IHOL0 BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the foUowing, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey. Check Septic Form N.Y.S.D.E.C Trustees Flood Permit Storm-Water Assessment Form Contact: Phone: · Building Inspector kTION FOR BUILDING PERMIT Date 0~/- 30 ,20 INSTRUCTIONS illed in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a pemut shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for a~ addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on promises and in building for necessary inspections. (Signature 9(a2~licant or name, ff a coq~oration) Nh' //97/ (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises '::3"'D ,~,F_... ? hi ,,,&-~ ~ (~P~ LO ~.- (As on the tax roll or latest deed) If applican's a tion, signature of duly authorized officer (Name ant~ftle of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section d 'lSlu'ts Block Lot 2. State existing use and occupancy of premij, qs and int~n, ded use and occupancy of proposed construction: a. Existing use and occupancy _ ]~ ES/15~OT/~ L b. Intended use and occupancy Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost /000 o?~.. 5. If dwelling, number of dwelling units If garage, number of cars ~( Fee Addition Alteration Other Work ~) F-C.g,- -' (Description) Number of dwelling units on each floor (To be paid on filing this application) 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front "~2'r7 ' ¢7l~?ar ~'~, ,3 ' Depth Height ~ Z.5-' Number of Stories / ? Dimensions of same structure with alterations or additions: Front Depth :5 & ~,,~ Height 8. Dimensions of entire new construction: Front Height / ~ ~ Number of Stories 9. Size of lot: Front ,~©1.~, ~(o Rear Number of Stories. ear 10 t/% Depth (~,5 ,ql~ Rear. Depth I0. Date of Purchase '~ [ Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ,,~ 13. Will lot be re-graded? YES NO 2<, Will excess fill be removed from _ _ premises? YES 14. Names of Owner of premises F6~.w Address ~c~4q-v~t.~ Phone No.. Name of Architect ~&,xr' ~ h~,~.~ &x.._qj~ AddressP, O,&~ 167~$¢o~1o.~ PhoneNo Name of Contractor t4~ Address N,h Phone No. 15 a. Is this property within 100 feet ora tidal wetland or a freshwater wetland? *YES * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C PERMITS MAY BE REQUIRED b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQ~D. NO ~- 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property9 * YES NO )q" · IF YES, PROVIDE A COPY. ' -- STATE OF NEW YORK) SS: COUNTY ovr,5~t3c~ ~ ~-'~Ti- b, ~'1 ~ t'q {__ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (s)I% is the /5 (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. 'qwom to before me this ~ day of - Notary Public Sign~gl~'of Applicant AREA = 37,7~8 eq. ft. JOSEPH BEST C~d~OL BEET THE L OI~ 151~4N0 SA VlN68 B~NK FS8 SUPERIOR ABSTRACT CORPORA TION TRW-S-54393B-I sURVEY OF ATSOUTHOLD TOWN OF SOUTHOLD 93 - 101 STATE ~C. ATION ~. AU~ ~9~ 20~ ( ~. ~w ad~fl~s ) ~ ~ ~ ~c~ ~ ~ ~~ S V~Y~.~. P C I I~'DA~T~~~ ~ [ ~~ o~v~i~oI r.~. I . ~ ~~~3/~ 765 - ~7 I ' X~~ sos ............... I , .. ,.~ ~ ,~ ,~ ~ s~r~o, ~.~. //.~/~1 Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C,T.M. #: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A STORM-WATER, GRADING~ DRAINAGE AND EROSION CONTROL PLAN CERTIFIED BY A DESIGN PROFESSIONAL tN THE STATE OF NL~N YORK, Item Number: 1 2 3 4 5 6 7 8 9 (NOTE: A Check Mark (~) far each Question is Required for a Complete Application) Will this Project Retain All Storm-Water Run-Off Generated by a Two (2") Inch Rainfall on Site? (This item will include all mn-off created by site clearing and/or constmcfon activities as well as all Site Improvements and the permanent creation of impervious surfaces.) Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location? This Item shall include all Proposed Grade Changes and Slopes Controlling Surface WaterFIowI Will this Project Require any Land Pilling, Grading or Excavation where them is a change to the Natural Existing Grade Involving more than 200 Cubic Yards of Matedal within any Parcel? Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000) Square Feet of Ground Surface? ts there a Natural Water Course Running through the Site? is this Project within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach? Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vertical Rise to One Hundred (100') of Horizontal Distance? Will Driveways, Parking Areas or other Impervious Surfaces be Sloped to Direct Storm-Water Run-Off into and/or in he d rec on ora Town right-of-way? Will this Project Require the Placement of Material; Removal of Vegetation and/or Ihe Construction of any Item Within the Town Right-of-Way or Road Shoulder Area? (This item will NOT include the Installation of Driveway Aprons.) Wilt this Project Require Site Preparation within the One Hundred (100) Year Floodp ain o any Watercourse? Yes No NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark in the Box, a Storm-Water, Grading, Drainage & Erosion Control Plan is Required and Must be Submitted for Review Prior to Issuance of Any Building Permit! EXEMPTION~ Ye~s N._R Does this project meet the minimum standards for classification as an Agricultural Project? Note: IfYouAnsweredYestothisQuestion, aStonm-Water, Grading, Drainage&ErosionContro P an is NOT Required! -- ~'~ STATE OF NE~7 YORK, COUNTY OF ....'~..9..~.....F.,Q,...%,(..(=., .............. SS That I,.....~......~...~.~t~. ......... ~: ......... {.~...~..~ ...................... being duly sworn, deposes anti says flint (Name of individual signing Document) CONNIE D BUNCH /keF_. ,~- Notary Fublic. Si~teof NewYo~ And that he/she s the L~]~'.,-.,~.t .......................... N~.,QI.BU6J.85050 .................... Owner and/or representative of the Owner of Owner's, and is duly authorized to perform or make and file this application; that all statement~ contained in this applica6on are true to fine that the work will be performed in the manner set forth in the application filed herewith. Sworn to before me this; ........ ......................... Notary Public: epe for}..~2ed thc said work and stof~ TOWN O~ SOU/HOLD FORM - 06/07 O~NE-~-R "~T-REET 'Z.~7~'~.~'_ VILLAGE DIST.__ SUB. LOT ACR REMARKS ~ -- ~- ~, .~1 I ~ ~t ,, TYPE OF BLD. loc ~ ~¢o~] IO~ o~ ' ~4q- ~ + ~ooo ~, ~005~ 36o~ ~o F~O~TAGE O~ wATE~ T~LLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT TOTAL / 'K I[ '- --- I ~ d~O Foundation Extension ~,x 2-~--~ ZZSJ ~4/ Z, 7~ /¢~ Basement ~x~on ~7 ~ I~= ~7~ ~ ~,~ ~/~ Ext. Walls Extension Fire Place Patio Woodstove BR. Porch Dormer Deck Attic Breezeway Rooms 1st Floor Garag~/~ X ~E ~ ~ ~ --:..~ ~y~ ~ /~ I, ~ Driveway Rooms 2nd floor o.. POOl~ ~ ~ ~ ~ ~ r/ Paradise Series SITE PREPARATION You probably have a spot picked out for your new spa, whether it's indoors or outdoom, on a patio or on a deck. Just make sure you check the following: · Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal Make certain that the location you choose can support the weight of your filled spa. · Don't forget to level your spa before filling it. (Sea the Spa Leveling Preparation section of this manual.) · Locate your equipment compartment, which houses a~l of the electrical components, in a place where water will drain away from it, AJlowing water into the equipment compartment can damage the electronics, or may result in tdpping your house's circuit breaker. o Leave youmelf easy access to the circuit breakers in the subpanel. · Never let water get into the subpanel. Your 230 volt spa's subpanel is rain-tight when installed correctly with the door closed. Peeddically cheek these conditions and correct any flaws if detected. · Leave access to the equipment compartment for periodic spa care and maintenance. A WARNING: Damage to the apo% equipment compartment components or internal plumbing as a result of rodent infestation is ~ covered under your warran¥ OUTDOOR AND PATIO INSTALLATION No matter where you install your new spa, it's important that you have a solid foundation to support it. Structural damage to the spa, resulting from incorrect installation, or placement on an inadequate foundation, is not covered under the spa's limited warranty. Watkins Manufactuhng Corporation recommends that the Caldera® spa be installed above ground. Lowering the top of the spa to 9round level, or employing decking which raises standing level toward the top of the spa substantially increases the hazard of accidental entr~. Consult a Iicansed building contractor to design or evaluate your custom decking requirements. if you install the spa outdoors, we recommend a reinforced concrete pad at ieast four inches thick. The reinforcing rod or mesh in the pad should be attached to a bond wire DECK INSTALLATION To be certain your deck can support your spa, you must know the deck's maximum Icad capacity. Consult a qualified building contractor or structural engineer. To find the weight of your spa, its contents and occupants, refer to the Spa Specification char[ on back cover. This weight per square foot must not exceed the structure's rated capacity, or sedous structural damage could result INDOOR/BASEMENT INSTALLATION Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa it is recommended that a floor drain be installeq. The humidity will naturally increase with the spa indoors. Water may get into woodwork and produce dry rot, mildew, or other problems. Check for airborne moisture's effects on exposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed. Caldera spas are equipped with a jet pump shroud to remove excessive heat from the equipment compartment. Find this vent and be sure the vent is not blocked by anything, including carpeting. Your Caldere dealer can help you with local information such as zoning regulations and building codes. SPA LEVELING PREPARATION Concrete sloped at 1 inch per 10 feat is preferred so that rain water and water spiliover will run off and not puddle underneath the spa (water under the spa for long peedds of time may cause the wood to deteriorate). Other options are brick, stepping stone, or blocks. It is important to note that soft surfaces, even when stepping stones are used to evenly distribute the weight of the spa, will have a tendency to settle, thus resulting in an unleveleq spa. 1 inch Slope 1 inch per 10 ft, for proper drainage. Stepping stones or brick may settle causing the spa to be unlevel. NOTE: Placing the spa on grass or dirt may increase the amount of debds which is inadvertently brought into the spa water and may cause harm to your equipment as DANGER. RISK OF INJURY. · Never leave a spa uncovered or unattended. · Never leave a spa cover unlocked. · Do not stand, sit, or lie on the cover. well as the spa surface, which is not covered under warranty. SPA COVER INSTALLATION · Place the cover squarely on the spa. · Position the tie-down looks included with your cover on the side of the spa so that they are easily reached by the cover tie-down straps. Allow for about 1/2" to 3/4" slack in the straps to make it easy to insert straps into looks and to compensate for vinyl shrinkage in cold weather. · Attach the locks with the screws provided and insert the cover tie-down straps into the looks. NOTE: Keeping the cover in place any time the spa is not in use will reduce the amount of time the heater operates, thereby minimizing operating costs. 10 ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera* Spa has been carefully designed to give you maximum safety against electrical shock. Connecting the spa to an impropady wired circuit will negate many of the spa's safety features. Improper widng may also cause erectrocutfon, dsk of fire, and other dsks of iniuries. Please read and follow the electhcal instarlation reculrements and instructions for your spa completely! SERVICE NOTE; All CaFdera spas have diagnostic functions that are displayed on the control panel. Four flashing lines are visible on the control panel if the heater high ~mit thermostat has tripped. If the four flashing lines are visible, follow the instructions in the troubleshooting section to identify and correct the cause. Tne four flashing lines will stop flashing once the problem has been corrected. _30 VOLT PERMANENTLY CONNECTED C,~ LDERA SPAS MUST BE WIRED IN ACCORDANCE WITH ALL APPLICABLE LOCAL ELECTRICAL CODES. ALL ELECTRICAL WORK SHOULD BE DONE BY AN ~PERIENCED LICENSED ELECTRICIAN. WE RECOMMEND THE USE OF APPROPRIATE ELECTRICAL CONDUIT, FI'FRNGS, AND WIRE FOR ALL CIRCUITS. An electrical subpanel containing two GFCI breakers is included with each spa. We recommend that this subpanel be used to supply power and p retecl the spa. This subpanel requires a 50 amp, single phase, 230 volt, four wire service (two line, one neutral, one ground). T~e ground wire must never be less than #10 AWG. Use NEC 250-122 (table) and local codes for more information. A minimum #10 AWG solid copper bond wire is also required. Mount the subaaner in the vicinib/of the spa, but not wrthin five feet, in accordance with local codes. INSTALLATION INSTRUCTIONS !. To connect the electrical service, first remove the screws from the equipment compadment door, lower the door one inch and remove the door. 2. Locate the spa control box. Remove the screws on the front of the control box and remove the control box cover. 3. Route the electrical service from the subpaeel into the spa equipment compartment. NOTE: The subpanel must be placed in sight of the spa, no closar than five feet. ~. Connect wire to bottom of control box using a minimum of 3/4" liquid-tight, flex conduit fitting. WIRING CONNECTIONS !. Identify the TBs1 terminal block, located inside the control box at the lower left-hand cornei: 2. Connect the #12 AWG, BLUE wire, from the subpane120 amp breaker, terminal L1 to TB-1, terminal 1 3. Connect the #12 AWG, RED wire, from the subpane120 amp breaker, terminal L2 to TB-1, terminal 3 NOTE: The WHITE neutral wire must be attached to the LOAD neutrai on the 230 volt, 30 amp breaker (not to the neutral bus bar in the subpanel). The WHITE neutral w~re coming from the breaker itself is already connected to the neutral bus bar. Connect the #10 AWG, BLUE wire, from the subpane130 amp breaker, terminal L1 to TB-1, terminal 2 Connect the #10 AWG, REP wire, from the subpane130 amp breaker, terminal L2 to TB-1, terminal 4 6. Connect the #10 AWG, WHITE wire, from the subpane130 amp breaker, terminal N (Icad neutral) to TB-1, terminal 5 Connect the #10 AWG, GREEN wire, from the subpaeel GROUND bar to TB-1, system ground terminal. Using the pressure wire connector provided on the outside of the control box, bond the spa to all exposed metal equipment or fixtures, handrails, and the concrete pad (if applicable) per N.EC. and local codes. 9. Replace the control box cover and securely tighten the fastening screws. Close and secure the equipment compartment door as follows: · Place top of door or panel directly below bartop against the frame of the spa. · Push bottom of door or panel against the spa frame. · Slide door or panel upward (pushing in on center of door) until screw holes line up. · Slightly pull on door or panel, if door rereains against the spa then replace the screws. · If the door does not lock into position, repeat the previous steps. 2 WARNING: FILL THE SPA WITH WATER BEFORE TURNING ON THE POWER! (See STARTUP AND REFILL PROCEDURES). Once your spa has been filled with water, turn it on and test all of the circuit breakers. NOTE: If both breekere immediately trip, verify that the #10 AWG WHITE neutral wire is connected from TB-1 terminal 5 to the N (~oad neutral) terminal of the 30 amp subpaeel breaker. Each breaker should be tested prior to each use. Here's how: Push the "TEST" button on each GFCI breaker, and observe it click OFE Wait 30 seconds, then push the breaker switch to the OFF (down) posrtion (to ensure that it has completely disengaged), then push the breaker switch to the ON (up) position, if you don1 wait 30 seconds, the spa's control panel may flash four lines on and off- t~7 again. ;¢ any of the GFCI breakers fails to operate in this manner, your spa may have an electrical malfunction, and you may be at risk of electrical shock. Turn off all circuits and do not use the spa until the problem has been correcfed by an authorized service agent. 11 A WARNING: Removing or bypassing any GFCI breaker will result in an unsafe spa and wiJJ void the spa's warranty, IMPORTANT: Should you ever find the need to move or relocate your Calders'~ spa, it is essential that you understand and apply these instaJlatJon requirements Your Caldera spa has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the spa to an improperry wired circuit wil negate many of its safety features. NOTE: Long wiring runs may require larger-gauge wire than stated. 230 Volt Permanently Connected 2JOY, 50 Amp, 2-POLE, CIRCUIT BREAKER (NON 0FCI) MAIN SERVICE ELECTRICAL PANEL NN WARNING! THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCl BREAKER WILL VARY BETWEEN MANUFACTURERS, CONNECTING THE HOT WIRE TO THE EUTRAL TERMINAL WILL CAUSE iRREVERSIBLE DAMAGE TO THE CONTROL BOX HEATER GROUND ~] TB1 *SUBPANEL WITH GFCI BREAKER~ Minimttm 5 FEET The Subpanel m~t be ~Jh/~,~Lo f the spa Do not exceed 50 FEEZ LESS THAN 100 FT. ~1 GRD CONTRO_ ~0~ '* Refer to NEC 250-122 (table) NOTE: The wire connections to GFC[ breakers are for reference only Always ensure the white neutral wire is connected to the Icad neutral of the 30 amp breaker *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. POWER CONNECTION ACCESS CONTROL B 230V WIRING ACCESS OPENINGS ON RIGHT& LEFT HAND SIDE PUMP DOOR EQUIPMENT COMPARTMENT DOOR 12 MARTINIQUE~ PARADISE OVERHEAD VIEW 1. Air Control 2. Euro Directional Jet 3. Temperature Sensor 4. Air Jet 5, MagnaSsageJet . 9. DiverterValv~. 6, MagnaJet : 10. Drain-' 7, VersaSsageJet' 11,Ught :' :: · 8, Versa Jet : 12, Ozone Jet 13. Control Panel 14. Pillow 15. Filter Compartment 16. Grab Rail 20' ?0.00' O 72 '20 "~/ SITE PLAN DISCLOSURE: SITE PLAN INFORMATION IS BASED ON A LAND SURVEY PREPARED BY JOHN T. LAND SURVEYOR. NEW YORK STATE LICENSE NUMBER 49618, SURVEY DATED e S5.S, METZGA LICENSED JUNE 25, 2002, )) ??o ~) 764.S6' qb qb SITE PLAN FOR CAROL BEST SITUA TED .4 T ,0T #l "MAP OF SOUTHOLD VILLAS" FILED JUNE 26, 1992 MAP NO. 9237 AT SOUTHOLD TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-70-01-6.2 SCALE: 1"--15' SURVEY DATE: JUNE 25, 2002 SITE PLAN DATE: APRIL 29, 2009 235.00, ??o 720. O2, 'dP dP. cb LQ' 0 PROJECT TITLE & LOCATION: BEST RESIDENCE 265 JASMINE LANE SOUTHOLD, NEW YORK SCTM # 1000-70-01-6.2 WORKNOTES: 5130 Main Bayview Road Soufhold, NewYork 11971 phone' (631)765-1862 fax 1631) 765-6820 E-Mail: CArm8888@aal cam SHEET NAME: SITE PLAN ENGINEER: 401NEER'S SEAL: JAMES DEERKOSKI, PE Professional Engineer 260 Deer Drive MatUtuck, NY 11952 651-298-7116 OWNERSHIP AND USE OF These drawings and specifications inc g the ideas, design and arrangements repre~ ed therein, are the property of East End Design Associates, LLC. No part thereof shall be copied, discJosed to others or used in connection with any work or project other than for which they have been prepared without written consent of East End Design Associates, LLC. PROJECT NO: DRAWN BY: CMA SCALE; 1" = 15' DATE: 04-25-09 SHEET INDEX: SP1 GROUNDSNOW I WINED LOAD SPEED (mph) 45 Ibs/sqft! 120 (mph) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA SEISMIC DESIGN CATEGORY WEATHERING SEVERE SUBJECT TO DAMAGE MODERATE FROM TO HEAVY SLIGHT TO MODERATE WINTER ICE YES SHIELD FROST LINE DESIGN UNDERLAY- DEPTH TERMITE DECAY TEMP, MENT REQUIRED FLOOD HAZARDS 1984/1998 WIND EXPOSURE CATEGORY LUMBER SPECIES AND GRADE ALL EXT DECK FRAMING MATERIAL ACQ NC PINE #2 AND BETTER AREAS OF STRUCTURE ;RAWL SPACE NA BASEMENT NA fIRST FLOOR NA SECOND FLOOR NA IHIRD FLOOR NA BALCONY NA LOFT NA ATTIC (HOUSEXo) NA ATTIC (HOUB£)(b) NA GARAGE NA ATTIC (GARAGE)to) ! NA BONUS ROOM NA SCREENED PORCHES NA SUNROOM NA DECKS 355 sq ft COVERED PORCHES NA COVERED ENTRANCE NA POOL HOUSE/ CABANA NA ACCESSORY STRUCTURE NA (o) WITHOUT STORAGE (b) WITB STORAGE MINIMUM UNIFORM DISTRIBUTED LIVE LOADS (in pounds per squore foot) USE LIVE LOAD DEAD LOAD EXTERIOR BALCONIES 60 10 DECKS (D 40 10 PASSENGER VEHIOLE GARAGES (o) 50 (o) 10 ATTICS WITHOUT STORAGE (b,e) 10 10 o) ELEVATED GARAGE FLOORS SHALL BE CAPABLE OF SUPPORTING A 2,000- POUND LOAD APPLIED OVER A 20-SQUARE-INCH AREA b) NO STORAGE WI~ ROOF SLOPE NOT OVER 5 UNITS IN 12 UNITS c) INDIVIDUAL STAIR TREADS SHALL BE DESIGNED FOR THE UNIFORMLY DISTRIBUTED LIVE LOAD OR A SOO-POUND CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE INCHES, WHICHEVER PRODUCES THE GREATER STRESSES, d) A SINGLE CONCENTRATION WiTH WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH SECTION R802,101, e) SEE SECTION R502,21 FOR DECKS ATTACHED TO EXTERIOR WALLS / ~ J (2)2x10 ACQ FLUSH GIRDER / WiTH 2x2 LEDGER 1~~/ ~l~"x 6" STK CEDAR DECKING -,. LOWER :CK .-'2x8 AGO UPPER DECK FLUSH GIRD~:~_ JOrSTS 1B"oc --~1 EXISTING KITCHEN NOTE: ALL SIMPSON HANGERS HAVE BEEN CERTIFIED BY AN ENGINEER TO HAVE REQUIRED AMOUNT CALCULATED FOR EACH CASE. A CAPACITY EQUAL TO OR GREATER THAN THE NOTE: PROVIDE SOLID BLOCKING IN ALL FLOOR JOISTS AND AND THE AMERICAN FOREST & PAPER ASSOCIATION FAMILY DWELLINGS, 2001 BBC HIGH WIND EDITION. RAFTERS AS REQUIRED BY THE BUILDING CODE OF THE STATE OF NEW YORK, (AF & PA) WOOD FRAME CONSTRUCTION MANUAL (WFCM) FOR ONE AND TWO NOTE: EAST END DESIGN ASSOCIATES, LLC. AND ITS ASSOCIATED ENGINEER HAVE NOT BEEN RETAINED TO INSURE PROPER INSTALLATION OF ANY MATERIAL OR WORKMANSHIP PROVIDED TO THIS JOB SITE. 2xB CEDAR TOP RAIL 2x~ CEDAR SUB RAIL 2x2 CEDAR BALISTER 2x4 CEDAR BOTTOM 4xDx16 SOLID BLOCK (MINB' 0" BELOW FINAL GRADE) J 2x6 CEDAR TOP RAIL 2x4 CEDAR SUB RAIL 2x2 CEDAR BALISTER 2x4 CEDAR BOTTOM ~x4 POST lx12 RS CEDAR BOX COVER 2x10 ACQ BOX BEAM (2)2x10 ACO GIRDER 4x4 ACQ POST 4xDx16 SOLID BLOCK (MINB' O" BELOW FINAL GRADE) 2x8 ACQ 16"oc. (FLOOR JOISTS) 2×2 ACQ LEDGER 2x8 ACQ FLOOR JOISTS 16"oc. I I 2, RSWG~. FRN~kNG & PLU~.i,~[~G ~, ~SU~TDN 4. FIHAE - OONST~UCTK}~ MUST BE OOMPLErE F~,; GO. AL~ OONSTRUCTION SHALL ME~ ~E REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OB CONSTRUOTION ERRORS, RETA]~ STORM WATER RUNOFF ~UR~UA,~T ?n OHAPTER 236 O( ;UPA ':" *"3 ,:IS U' ' .i'UL CR SS S N © COPYRIGHT 2009 EAST END DESIGN ASSOCIATES, ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAW. PLANS MAY NOT BE REPRODUCED WITHOUT ALLCONSTRU~;TImNSk WRITTEN AUTHORIZATION. MEET THE RECl! 'I ALL PLANS AND DESIGNS ARE THE SOLE EAST END DESIGN ASSOCIATES, LLC, THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE PLANS IS LICENSED EXCLUSIVELY TO THE BUYER. PROJECT TITLE dc LOCATION: BEST RESIDENCE 265 JASMINE LANE SOUTHOLD, NEW YORK SCTM # 1000-70-01-6.2 WORKNOTES; EAST END DESIGN ASSOCIPfI'IzS, 5130 Moln Boyvlew Rood Soulhold, New York 11971 SHEET NAME: DECK FLOOR PLAN AND CROSS SECTIONS ENGINEER: :JAMES DEERKOSKI, PE 'Professional Engineer 260 Deer Drive Mettltuck, NY 11952 631-298-7116 OWNERSHIP AND USE OF These drawings and specificotions including the ideos, design ond orrongements represented therein, (]re the property of E~st End Design Associetes, LLC, No p~rt thereof shell be copled, disclosed to others or used in connection with eny work or project other then for which [hey hdve been prepered without written consent of E~st End Design Associetes, LLC, ~ROJECT NO: 90~ -PO09 BY: CMA SCALE: 1/4" = 1'-0" SHEET INDEX: S101 04 23 09