Loading...
HomeMy WebLinkAbout33889-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPARCY NO: Z-33738 Date: 05/27/09 THIS CERTIFIES that the building DECK Location of Property: 13090 SOUNDVIEW AVE (HOUSE NO.) (STREET) (HAMLET) County Tax Map NO. 473889 Section 54 Block 3 Lot 14.4 subdivision Filed Map No. Lot NO. __ SOUTHOLD conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 5, 2008 pursuant to which Building Permit NO. 33889-Z dated MAY 12, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The Occupancy for which this certificate is issued is "AS BUILT" DECK ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to ROBERTA ROSENBERG (OWNER) of the aforesaid building. SuFfOLK COUN~f DEPARTMENT OF HEALTH APPRO%~AL BLEC-rKICAL CERTIFICATE NO. I~LU~ERS CERTIFICATION DATED N/A N/A N/A ~tho~ i n&t%lre Rev. 1/81 Form No. 6 TO~ OF SOUTHOLD BUILDING DEPARTMENT APPLICATION FOR CERTIFICATE OF OCCUPANCY I/~tN.A . This application must be filled m' by typewriter or ink and submitted to the. Building Departm~nt.[wig the following:Dtt)G. DEPt. A. For new building or new use: I.~ fOW~ OE S0UID0tO 1. Final survey of property with aeonrate location of all buildings, property lines, stx~, and unusual natm~l or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-dispesal (5-9 form). 3. Approval of electrical installation from Board of Firo Underwriters. 4. Sworn statement from plumber c~-~dfying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, indushial building multiple reaidone~ and similar buildings and installations, a certificate of Code Complianea fmTM arehite~t or ongin~er responsible for the building. 6. Submit Planning Board Approval of complated site plan requirements; For existingbuildings (prior to April 9, 1957} non-conforming uses, o? buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streetS, building and.unusual natural or topographic features. 2. A properly completed application and consent to inapoct signed by th~ applicant. If a Certificate of Oocupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Oocupancy - New dwelling $25.00, Additions to dwelllng $25.00, Aheratiuns to dwelling $25.00, Swimming pool $25.00. Accessory building $25.00, Additions to aocessory building $25.00, Businesses $50.00. 2. Certificate of Occopancy on Pre-e;~iating Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5, Temporary Certificate of Oceapaney - Residential $15.00, Commercial $15.00 Old or Pre-existing Building: House No. S~t New Construction: Location of Property: Owner or Owners of Property: //P~/3 Z"~/d- 7"-/4 Suffolk County Tax Map No I000, Section ._.~¥Z Block (check one) Hamlet Lot Subdivision Permit No. ,..~3 ~'o° Health Dept. Approval: Date of Permit. Fried Map, Lot: Applicant: /~P'-~7'-~ /~-AJ,~'~:~" Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ 3 Finai Certifieate: (chock one) Applicant Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33889 Z Date MAY 12, 2008 Permission is hereby granted to: ROBERTA ROSENBERG 13090 SOUNDVIEW AVE SOUTHOLD,NY 11971 for : "AS BUILT" DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at County Tax Map No. 473889 Section 054 pursuant to application dated MAY Building Inspector to expire on NOVEMBER 13090 SOUNDVIEW AVE SOUTHOLD Block 0003 Lot No. 014.004 5, 2008 and approved bythe 12, 2009. Fee $ 400.00 Authorized Signature ORIGINAL Rev. 5/8/02 rchitectura£ ®esigns, ®. C. &.O. ~o;c 2192, &atchogue, .oZ. 11772 q~e~ (516) 848-8232 q~mai[.' .~4~Design&ermitsO ao£ com May 12, 2009 Town of Southold - Town Hall Building Department - Inspectors 53095 Main Road Southold, NY 11971 Re: Rosenberg Residence 13090 Soundview Avenue Southold, N.Y. 11971 Section: 54 Block: 3 Lot: 14.4 To Whom It May Concern, Please be advised that the construction of the Y-0" deep footings for the front wood deck at the above referenced property has been installed in accordance with and meets or exceeds the minimum standards of the Residential Code of New York State. If you have any questions or concerns, please contact me at (516) 848-8232. Thank you. Sinc~y, I Angela Mangels, R.A., A.I.A. Licensed Registered Architect , TOWN OF SOUTHOLD April 4, 2009 NOt 'T'FI t=Ot K IDt AI TIN® $ ID I®N PO Box 420 Mattituck NY 11952 Southold Town Building Department, This letter is in reference to an existing as built deck for Mr. Bob Cavagna residing at 13090 Soundview Ave. Southold NY, drawn by North Fork Drafting and Design, job #104 on 9-18-07. The drawings reflect and existing 14'-5" x 4' deck attached to the front of the residence. It is to the best of my knowledge that the preexisting deck is and was built as illustrated in these drawings submitted by Mr. Cavagna. North Fork Drafting and Design does not assume any liability for any misinformation on the plans that is not accessible or visible on site. John Rabkevich FO~ATIO~ (1ST) FO~DATION (2ND) ROUGH F~G & PL~G LNS~ATION PER N. Y. STATE ENERGY CODE TOWN OF SOUTH~)LD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork.net PERMIT NO. Examined ~t,¥ , 20~ Approved t)/~\)/, 20 0~ Disapproved a/c Expiration BUILD1NG PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Building Inspector APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS Mail to: Phone: a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection thxoughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Mailing address of applicant) g/9'7/ State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Nameofownerofpremises /~/3~a-/dT-/-~ ~(gC>~-~A/zS',~--.~F~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section Subdivision Block Lot //¢/. Z~ Lot ?~) ~:~/ 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration x,/''' Repair Removal Demolition Other Work Estimated Cost ~'TdP~, tSvt59 Fee If dwelling, number of dwelling units If garage, number of cars Number of dwelling units on each floor (Description) (To be paid on filing this application) ///,4 If business, commercial or mixed occupancy, specify nature and extent of each type of use. 8. Dimensions of entire new construction: Front G,q Height ['7 ' Number of Stories 9. Size of lot: Front /~dT' Rear Dimensions of existing structures, if any: Front G ~?c ' Rear ~ ~ ' Height. ! 7 ' Number of Stories Dimensions of same structure with alterations or additions: Front ~f~ ' Depth ,"~0 ' Height '7 ' Number of Stories Rear Depth Depth ,.~O ' Rear Depth ~-~, '7 ' 10. Date of Purchase ,~/,4~d// ,~t~vt9 Name of Former Owner Cd~/2~-~' 11. Zone or use district in which premises are situated flo~.S~-~_)~--,~/7-/,,q t_ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO V/ 13. Will lot be re-graded? YES NO /Will excess fill be removed from premises? YES NO V/ 14. Names of Owner of premises 2q}~d/~ fl~e~/~E4~ Address/~o?o ~u~)v/E~J Phone No. (:,ff/' Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO _ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ · IF YES, PROVIDE A COPY. NO V/ STATE OF NEW YORK) ss: COUNTY OF )(" ~0 ¢& C3r-c~ [~O~q~--'~ ~q-~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc0 of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of/~ O~ _ 200~ Not ublic Lo,mine NO. 01LA6059257 Qua fled In Suffolk CoUflN Commi~lon Expires- May Signature of Applicant TOWN OF SOUTHOLD PROPERTY IIECORD CARD ~:~¢~ ------ ~-,nr'tr~)'~VNER ~'C~-~ K'I~(-C~ STREET ) ~ ' VIL~GE DIST. SUB. LOT :ORMER OW~ERC~ ~ ~ ~O~C N E~6 / ACR. ~ L~k~ ~c {~ ( S W ~ TYPE OF BUILDING ES~)~ S~S. VL. ~ FARM CO~. CB, MICS. Mkt. V~lue ~ND IMP. TOTAL DATE REMARKS : / / ul~lo~ B~S~: mm,o+ ~on _ _ _._ liable FRONTAGE ON ~A~E~ 'o~lond FRONTAGE ON ROAD eodowl~nd DEPTH ~use Plot BULKH~D )roi 54.-3-14.4 1/08 M, Bldg!5 7' ExtensiOn~t'~ Extensio/n~ Extension Porch Breezeway Garage Patio O.B. Total /o Foundation Basement Ext. Walls Fire Place Type Roof Recreation Room 'Dormer / Bath Floors Interior Finish Heat Rooms 1st Floor Rooms 2nd Floor Driveway inette DR. 3R. FIN. B COLOR M. Bldg--./~r E. /.s,~ xtenslon ' Extension ,.,.,g ~ o ~ 0 2"X8" ACC LEDGER D ~ATE:_~/~ ~ LAG BOLTED TO HOUSE 0 ~ ~ :-- - o : , ~"X6" TOP DECKING ~ ~LLOW:k~ :,~S, ~TL~NS: I }k ACC DJ ~ 16"0C ~Z eRA~[ PO STOOP v GRADE ~( ACC GIRDER -- I I I I~ 0 ~ , '- 2)2"X6" ~ ~ FOR PC.IJRED GC'~[CRETE % ~ ~ ii ~ ] { . ROCGH- FRAMING & PLUMBING = '~ ~ "X4" ACC POST ~ ~ f I 4, FINAL - CONC]~qU,¢T~ON MUST 0 ,~ ~ 8,, ~ Lj LJ BE COMPLETE i:,,q C.O. I ~¢ ¢~ IN PC PIER ALL CONSTRLLII~;: SI4ALL MEET ~E ~ ~ g~ REQUIREMENTS OF ;HE CODES OF NEW 0 ' .... '-' EXISTING ELEVATION ,o~,,~,*T~.,OT~*o,~,~[,o, Z --~ DESIGN OR CONSTRUCTION ERRORS. ~ 4' SECTION A A ~"= ~'-o" ~ OCCUPANCY'" ~,', ~ USE IS UNLAWFUL z WITHOUT CERYlRCATE OF OCCUPANCY o 0 ~2"x8" ACC LEB6ER Lac BOLTE~ &LLCONST~Lm'Fk'~NS~ALL EXISTING HOUSE I ~XlST~G HOUS~ % ~ PO STOOP ~ PO STOOP ~ ~ I , , ' 5 I .0.. I 4"'X~" ACC POSt ' ~4'-5" I IN 8" PC PIER~ (2) 2"X6" ACC ~ 0 ~XISTI~G DECK ~AM ~XISII~G FOU~DAIIOr~ ~A~ ~: '~ dO~ ~: SHEET NOTE: THESE ARE AS BUILT DRAWINGS DECK WAS CONSTRUCTED PRE HIGH WIND CODE OF 200~ · HOMEOWNER CONFIRMS PRE EXISTENCE ] OF1 IN -F UC;FIO MA TE I L NOTE : 1. ~LSPEClFIEDF~STEN~RS~S~B~I~T~L~BACCO~IN~O~fl~ t GON TRUGTION PROPOSED: INTERIOR AL TERA T/ON ~RI~N~EST~DPA~RA~TION(AF i/ INCORRECT FASTER QUANTI~ ~IZ~ ~ ~ ~RIAL, OR FINISH ~ Y & PA ) W~D F~E ~UCTION ~U~ FOR ~E~D f. ASP~ T SN~GLES ARE TO BE INSTATED (8 ~ x 31) & ~NNOT BE REPUTED WI f$D SIN~R$ (9 GA x 3~ ~ ~LE$S ~L ~NS~UC~ IS TO BE IN ACCORfl~CE WI ~E ~W 2 3~ FEL, T P~ER (MIN) OR ICE SHIELD ON 4:12 ,~I~I~,,S~UC~ES&~,AR~EREO~S~LL. 3, f.'PL~D$H~THING - /-/~F/T ~ x/~ GA~GL/L,~/O/V OF1"LA~ERT~NTflEB~T ~ (~Rf~TNDS,$ECTIONa. Zf) C~S~UC~D~LYS~Rr~L~,I~L~D~D 4, RI~EORSTRUCTU~LRIDGEASNO~D ~ ~,:,o~ ~,t,o. I s~/t~, . c ir :~ x LOADS, LI~LOA~, ROOFLO~S, FL~RL~, SNOWL~D~ ' Y~K~TA ~ ~) R30f 'L~/, , WELDING~LVAN~DSTEELMAYPNODU~MFULF~,E$: FRO, FI~f.2(4)EQ~EX~EDf,O,~S~,L ~S-,~ WELDtNGSH~LDBEINACCORDAN~W/AWSST~D~D$ PAP~A~IOIA~(~&PA)W~F~C~UC~ION 9. I~"FASCIA&~KEBOAR~DW/~UMINUMCAPPING ~ ~ INJURE ~E OPE~ TOR OR O~ER$. ~IL ~8 ~ Y SE U$~ ~ ~ A~L ELEC~I~ ~RK ~ TO ~E ~.~ ~ N~ Y~K IN$TALLCONNECTOR~PROVIDED~ECORRECTQU~TI~&~FEOF OFE~ECTRI~LFI~Eg~ER~I~R~E~CTRI~ALEQUIP~ 11, VIN~F~LVEN~NG$~FIT$ O~E ~m~ ~ ~ NAILS ARE PROPERLY INSTALLED IN ~E ~IL ~LES. T~L$ W/ ~IL AND ~NG 8~L BE INSTALLED La.w. PART VIII, ~RS INSTRUCTIONS & USE ~E APPROPRIA TE ~F~ EQUI~NX ~TI~ ~QUIPM~NT ~L~ NOT B~ O~RB~ED BY ~E ~ ~ 4. AR~I~CT S~L ~OT~ ~$~18~ F~ ~E ~K g I~' FA~FOLD RIGID INSUM T/ON ~ ~ ~' BE~EN ~E JOIST END & THE NOR 8~L ~T ~CEED l.N ~R A$~ RE~ T~G TO THE C~CTOR$ ~E~UTI~S OR TO ~ '~ TESTSTANDARD~ M~N~M~O~CNN~E$ORP~DURESREQUIRED 3. ~C~OUSEW~POREQUAL ~ ~ 1 TO 1 TURN W/A ~ENC~ WI CONEIDE~ TI~ Glen ~0 ~SLE & ALL $T~UC~L L ~SER TO 8E ~S FI~ ~ HEM FIR OR 8E ~ & f~' GY~UM BOARD ~ ~ ~ ,~ FUTURE W~D $HRIN~GE CARE SHOULD BE TAKEN TO NOT WI UNIT $~REES ~ ~ P$1& MODU~S OF E~TICI~ NO~: , ~D,, L ~E$E P~N$ ~ I~ $~RI~ GONFO~N8~ ~/~ NEW YORK $~U~KU~ ~ ~ TO B~ ~U~ Y ~ TO TOP O~ I.R. ~ I~ ~RIOR W~LL$ C~ON ~/LIVING ~R~$ ~ ~ ~ ENERGYCONSERVA TION ~ES~ ~D ~L Y3, ~2 FOUN~ ~ W~L ~ $U~T C~U~LO~ CO~ WI~OE THISSITEP~N/S NOTALEGAL SUR~ ~ THERMOSTAT~MPE~C~TR~S~YNOT~CEED 75'F ~. ~US~E~L~IS~H~RS& ~IMMERS~D~L ~ENIN~ 2. R~INALL ~THED~L CEIUN~W/HURRICANE~SUNLESS~TED /T IS FOR ILL UST~ TION PUR~ES ONLY / ~ FOR H~ TING & 7O'F FOR C~LIN~ ~O~DE EI~ER 8WITC~ & UNDER ALL P~lO~ ~ ~CO ~N~ERS. ~DE ~IDGIN~ O~ERWI~E ALL D/~ENSION~ SETBACKS, LOCATIONS & ~ CL~KOR ~NUAL CON~Ot $E~CK ~ 8'~0. C. & ~N~ ~E~8~E STR~TURESWERETAKENFROMSURVEY ~ 3. INSV~ONTO8EINST~EDINA~NERTO~O~DE N~R$OFE~E~D~A~M~IC~M L/CENSED ~ND SURVEYOR ~/? ~c~/ ' CORNER P~ TES ETC' Z ~ NOT S~E ~. CONT~CT~ .~ VER/~ ~ Di~EN~S, i. ~ H~ER$ A~ TO SEA M~ OF (2) 2~f~ & ~U~E JACK E~ ARE RODERICK BAN TUGL, PC ~ 4 MOIS~RE VA~R R~ARDER I$ TO 8E ~STA~ED ~ ~E . EL~A T~N$ & G~ AT ~E ~ ~ ~ ~ GREENPOR~ NY ~ ' - W~IN. WINER SIDE OF ~E I~U~ ~ IN AlL F~ ~ $~LE ~ T~ P~C~ O~ ~ SCALE DA TS. APRIL 2~ 1977 ~/ ~ W~L& FL~RS, R~F AND CEILINGS ~PRISING E~ENT$ 2 ~USLE J~ST UNDER ALL PA~LEL PAR~EONE ~ ~ULKING~ERSTRIP~O~DEDATALL ~N~, A) ~RI~W~L: ~13FOILFAC~RS~INEU~I~ ~ P~VIDEFIREST~PINGAE~R~EC~E ~r~ ~O~FO~ PLOTPLAN SCA~' ~"=~O' ~R&SlLLS, C~CK$,JOIN~WALLP~EL$~DUTIU~ 8)~ILI~:R~cFOILFACEDR~G~INS~EON 4. ~ERHE~CU~S~NOT~CEED4' SEC' ~ SER~CE PRO~CmR~ ETC. C) ~ AT C~ ~ACE' R. Ig K~ FA~D F~ERG~$8 IN$U~ ~ ~ ~IN. M~AL ~NNEC BLK' 3 ~ /NELL ~ON ~ ~$ARE NOT ~0 ~CEED ~EFOLLOWIN~' I~T~L AS ~R~UFAC~R~ $PECIFI~ TIO~ LO~' 14.4 WINDO~O.3CF~SE SL/DINGG~R$~3C~E MOi~REV~R~DERiSTOSEiNBT~L~T~WA~Wi~$tDE COMPR~ING E~E~8 ~ ~E ~UILOI~ TNER~ EN~LO~ /&~ SECTION R3~ & ~E$EP~N$&SPEC/FICA~SHAVESEENPREPA~DUNDER 1. ~USLEFL~RJO/E~UNDA~L S~LIGNT8, $TAIRS&OPENING8 ~EDIRECTIONOFTHEUNDER8IGNED, TO~ESESTOF~E 9. TAPE~D~A~EA~G~SUM~A~YFORPNNT/N~ KNO~EDGE ~PERIENC& INF~TI~ & 8EU~ TO ~NFORM USE 1~" G~SUM BO~D FOR~L W~S & CEIU~. ~ ~0 THE RESIDENT/AL 8UI[DIN~ CODE ~ N~ F~K 8TA T~ WA~ AND CEIU~ F~ISNE8 8~ BE ~a,~ 8EC~ R3I~AND SEE WIND BORNE DEBRIS NOTES aE N~S~LIGHT' ~RIORW~L~RI~LBE ~a.w. SEC~R~ ~ ~ ~ (~x~) ~(~.~) ~.~1 VEN~TI~ES~UGH~ze~~ ~1. ~E~ONRYCH/~Y~BE~TR~Za.~SECT/ON1~t LIGHT, ~TION AND H~NG IN A~ORDANCE W~ SECTION ~A ~r~ EXm~ ~R~ ~NT, 12 ~E~CHI~CT~$NOT~EENR~AINED TO,REaM 8PE~REDIN THEWFCMWOODF~MECONE~UCTION~NUAL I~6EOITION&SBCHIGHW~NDEDITION ~ ~ [ ' ~0~ ORE~ . FtELflSUPERVIEI~RI~NS~UCTD~ EXISTINGF~Nmn~mRemlN I / f~ IFINTHE~UEEE~C~E~ACONDITION~ISrS~ICH ~ o~. CON~CTOR ~ 8~P ~& ~ T~ARCHI~C~ S~ULD T~ CONT~CTOR ~ TO ~LL OW ~I$ ~DU~ & C~NUE ,' 8~" / 8~" / 8'~' 4 ~E~~ EXI¢TING~LLYTOR~I~ ASPERNYSCR317 ~ q r' / ~ ~P OF~LL k~ ~o' / ~1 ~'¢' ' ~ Ii ~J~" IF ~t -/- ~' L, ~ ~ ~lS ~NG 8~8 TO REMAIN ~ J ~ W~L HEIGHT TO ~ ~E~EO