HomeMy WebLinkAbout34673-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-33718 Date: 05/18/09
THIS c~RTIFIES that the building WOOD STOVE
Location of Property: 11305 MAIN RD MATTITUCK
(HOUSE NO.) (STREET) (HAMLET)
County Ta~ Map No. 473889 Section 142 Block 2 I~)t 19
Subdivision Filed Map No. __ Lot No. __
conforms substantially to the Application for Building Permit heretofore
filed in this office dated MAY 11, 2009 pursuant to which
Building Permit No. 34673-Z dated MAY 11, 2009
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is WOOD STOVE IN A NON-HABITABLE ACCESSORY BUILDING AS APPLIED FOR.
· ~me certificate is issued to GEORGEANN PACKARD
(OWNER)
of the aforesaid building.
SUFi~)5iCOOI~I~fDEP~RT~NT OF~F2kLTHAPPROVAL
ELRt-£KICAL U~K'rIFICA/]~ NO.
PLL~4BEI~S CERTIFIC-ATION DASD
N/A
N/A
N/A
'/~~/A~~S ignature
Rev. 1/81
· ' TOWN OF SOUTHOLD ~.,~S',~a0~~~ ---
Form No. 6
765-1802
APPLICATION FOR CERTIFICATE OF OCC.~
. .
~is apphcatlon must be filled in by t~ewdter or i~ md sub~aed to ~e Building Depmi~
A. For new building or new use:
1. F~ su~ey of prope~y wi~ a~te l~tion of ~1 buil~ngs, pr0pe~y lines, s~ets, ~d unus~l nail or
topo~phic feat~es.
2. F~ Approval ~om Heal~ D~t. of water supply ~d sewemge~sposal (S-9 fora).
3. Approval of electfic~ inst~lation ~om Bo~ of F~ Unde~fite~.
4. Sworn statement from plmber ceding ~at ~e mlder used ~ system contains less ~ 2/10 of 1% lead.
5. Co~ercial building, indmffial buil~ng, multiple residences ~d s~l~ buildings ~d inst~lations, a ceffificate
of Code Compliance ~om ~chit~t or engineer responsible for the building.
6. Submit Pl~ng Bo~d A~roval of completed site pl~ mq~mments.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25,00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Old or Pre-existing Building:
House No. Street
New Construction:
Location of Property:
Owner or Owners oferoperty: ~O r~E~I t~
Suffolk County Tax Map No 1000, Section { ap
Subdivision
(check one)
Hamlet
Block 00 0 ~. Lot ~ [ t:~
Permit No. _~ 4{~
Health Dept. Approval:
Filed Map. Lot:
Dateofeerrnit. 5/lt/6 ~ Applicant: ~0Q~ ~g~t~x
Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $ ~L~, ~
Final Certificate: J (check one)
pp~t~tant Signature
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 34673 Z Date MAY 11, 2009
Permission is hereby granted to:
GEORGEANN PACKARD
PO BOX 648
MATTITUCK,NY 11952
for :
INSTALLATION OF WOOD STOVE IN A NON-HABITABLE ACCESSORY BUILDING
AS APPLIED FOR. REPLACES EXPIRED BP # 31970
at premises located at 11305 MAIN RD MATTITUCK
County Tax Map No. 473889 Section 142 Block 0002 Lot No. 019
pursuant to application dated MAY 11, 2009 and approved by the
Building Inspector to expire on NOVEMBER 11, 2010.
Fee $ 75.00
Authorized Signature
ORIGINAL
Rev. 5/8/02
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUIIJDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 31970 Z Date MAY 8, 2006
Permission is hereby granted to:
GEORGEANN PACKARD
PO BOX 648
MATTITUCK,NY 11952
for :
INSTAIJ,ATION OF A WOOD STOVE IN A NON-HABITABLE ACCESSORY BUILDING
AS APPLIED FOR
at premises located at 11305 MAIN RD
Cou~nty Tax Map No. 473889 Section 142
pursuant to application dated MAY
MATTITUCK
Block 0002 Lot No. 019
4, 2006 and approved by the
Building Inspector to expire on NOVEMBER 8, 2007.
Fee $ 75.00
~ature
Rev. 5/8/02
ORIGINAL
3/
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INS~JL~ION
[ ] FRAMING / STRAPPING [ ~ FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS:
DATE ~ /,-,-~/~/ INSPECTOR~
I~'~LD INSPECTION REPORT I DATE l
FOUNDATION (1ST)
FOUNDATION (2ND)
ROUGH FRA.1VII~G &
PLUMBING
INSULATION PER BI. Y.
STATE EBIERGY CODE
F12~AL
. ADDITIONAL COMMENTS
TOWN OF SOUTHOLD
BUILD,lNG D,EPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www. northfork.net/Southold/
Examined
Approved ~f~./ ,20~
Disapproved a/c
/
Expiration ! ¢~-,~ ,20
PERMIT NO. '3 iq :/~ ':~
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Plmming Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Contact:
APPLICATION FOR BUILDING PERMIT
INSTRUCTIONS Date
Mail to:
Phone:
3 ,20 c3
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for mi
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffblk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessaryinspections. //~
// (I {.ghamre of applicant or name, if a dorporation)
iMafling address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name ofowner ofpremises ~2d'O~ d. 0a.t,1 [~. (9~£~r'4~' {,.~ol~7~o{xgx.,tC~,~r_,(m; 1,3/G~"- il 71~_._,
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer & ~/~- 5~g 3- ¢6 d-/~/
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
House Number Street
County Tax Map No. 1000 Section
Subdivision
(Name)
Hamlet
Block
Filed M~
2. a. Existing use and occupancy d~at-zck~
State existing use and occupancy of premises and intended use and occupancy of proposed construction:
b. Intended use and occupancy
Nature of work (check which applicable): New Building
Repair Removal Demolition
Estimated Cost ~7 / ~ OD
If dwelling, number of dwelling units
If 9arage, number of cars
Fee
Addition Alteration
~her Work '~vtSg'a.({a_~
'----- ~ (Description)
(To be paid on filing this application)
Number of dwelling units on each floor
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
i~ ! q-q Rear [C(I tlL tt Depth
7. Dimensions of existing structures, if any: Front
Height ( ;~ ' ~ ~' Number of Stories I
Dimensions of same structure with alterations or additions: Front
Depth Height_ Number of Stories
Rear
8. Dimensions of entire new construction: Front
Height Number of Stories
9. Size of lot: Front ~-~-- r' Rear 0-5'-
10. DateofPurchase t~'qaS0~F' tqm/ Name ofFormer Owner
Rear .Depth
_Depth ,:¢q SD- [~ /
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded? YES__ NO t//will excess fill be removed from premises? YES__ NO__
14. Names of Owner of premises ~-~:7~,-C~£,"~{ Address t% .~ )t 0z(--~' Phone No. fl-q2~- ~ ;a-ftc>
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE;,gEQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
NO
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
COUNTY OF ~/(-*(kS)S:
~--~ a~"~)~ rl~ K- ~])~.ck ~ v'~( being duly s~voru, deposes and says that (s)he is the applicant
(Name of~ndividual si~ing contract) above named,
(S)He is the
(Contractor, Agent. Corporate Officer. etc.)
Sw. om to before me this.
~q'J day of /t~/~-/..~. 20
IIMI~ Public S
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
' Signature o f Applicant~
iq 49'02'40" E
55.00'
Z
$ 49.0')'40" W
55.00'
lvIAIN R. OAD
i~SURVEY OF PROPERTY
SITUATED AT
~ MATTITUCK
TOWN OF' SOUTHOLD
SUFFOLK COUIqTY, NEW YORK
S.C. TAX No. 1000-142-02-19
SCALE 1"--20'
NOVEMBER 22. 1993
AREA = 13,726.24 sq. ft.
CERTIFIED TO:
CHICAGO TITLE INSURANCE COMPANY
CENTERBANK ~ORTGAGE COMPANY
STATE OF NEW YORK MORTGAGE AGENCY
ROBERT S. WHITE
Joseph A. Ingegno
Land Surveyor
93-30:~
COLOR'
M.
Porch
Po~h
P~io
O, Bo
Tol~,l
· ~ou~cJation .
· , WOlls
PJace
Roof
reation Room
Interior'Finish
IDinette
Rooms 1st Floor
)riYe,,voy
APPROVED AS NOTED
DATE: ~/~'/~, B.P.# $/
FEE: ,,~J' ~;~'~,~2
NOTIFY BUILDING DEP~TMENT AT
765-1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION - TWO REQUIRED
FOR POURED CONCRETE
2, ROUGH - FRAMING & PLUMBING
3. INSU~TJON
4, FINAL - CONSTRUCTION MUST
BE COMPLET[ FOR C,O.
ALL CONSTRUCTION SHALL
MEET THE REQUIREMENTS OF THE
CODES OF NEW YORK STATE,
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
ALL CONSTRUCT
REQUIREMENTS ~
YORK STATE. N(
DESIGN OR COk
.............. ~) STOVE
~F.i~.P.~N SIR L E FOR
~m~ ERRORS.
Geor~eann Pa~ard
~3o5 Main ~oad
Mattituc~ New York
Scale: ~/2" = ~_'
May 3, 2006
NOTES:
· Installation follows all manufacturer's specifications for
Jotul Freestanding Wood Stove.
· Chimney will come out of top of stove.
· Stove will be installed by United Chimney Corporation,
14ol Church Street, Bohemia, NY 11716, 631 563 4641.
Copy of work order attached containing materials to be
used.
· Btack stove pipe on interior section is stainless-steel lined.
· Ceiling of structure is open rafters, 24" on center.
· Structure has Certificate of Occupancy.
I
Stove sits on
x ~' Cerami Tile
over 4" m~'
Concrete Floor
Stove is
centered between
North and South walls
(9' ~" from each wa~O
with pipe coming
from the stove's top
centered between
open rafters. Back of
stove is 3' from wall
behind and all
combustibles.
1401 CHURCH STREET,, ~
BOHEMIA, NY 11716 (' ~'/ \ )
631-563-4641 \ ~-~ '~'
Fax 631-563-8970 ~
1 (888) PRO-SWEEP
www. unitedchimney, net
CUSTOMER
ADDRESS
[?A ·
Westchester Lic.# WC10018H 99
Nassau County Lic. # H0708030000
Suffolk County Lic. # 27011-HI
Southampton Lic. # 2780
East Hampton Lic. # 5107
DATE day date time
COMPLETE
DATE day date time
CITY
X-STREET ~')~.
CONTACT -
SALE DATE ~ -:~\- O~'
SERVICE INSTRUCTIONS
SWEEPS COMMENTS
AREANO.
STATE 11'~ '-~ PHONE(H)( )"7-.c~'-
ZIP ~~,°t ~" o~- PHONE (B) ( )
CUSTOMER TYPE SRVC MNGR#
PROSPECTS SOURCE
t SUB-TOTAL
*ALL CUSTOM WORK REQUIRES A SALES TAX
TOTAL
50% NON-REFUNDABLE DEPOSIT. CREDIT CARD DEPOSIT
Signature: CHECK NO. DUE ON COMPLETION
***30 DAY SATISFACTION GUARANTEE*** The¢~ I$ · $35.00 fee for returned checks.
UNITED guarantees that if you are not 100% satisfied with the service performed on your home, UNITED will reservice those
areas at no additional charge to homeowner. In addition, for your protection UNITED is fully insured, including liability and
workman's compensation.
In the event that a payment is not made within 30 days from the date of completion, the buyer shall be responsible for an additional
25% for collection fee.
"YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS
DAY AFTER THE DATE OF THIS TRANSACTION. SEE THE ATTACHED N.O,,TICE OF CANCELLATI~IN FOR/M FOR AN
EXPLANATION OF THIS RIGHT / ~ /
S,G.ATURE DATE
American Fireplace Stove #8
Glass door standard. We have designed these stoves
knowing you want to view the fire. The large glass door
is standard equipment. A fire screen is also included for
open fire viewing.
Porcelain enamel finish. To complement your home's
decor, Jotul stoves are available in durable and attractive
decorator colors. These colors allow Jotul stoves to have
the appearance of a fine piece of furniture.
Maintenance is very easy and your stove will retain
its '%rand new" look year after yea~
Jotul is highly skilled in the enamelling process and
is able to offer it to you at an economical price.
Cast iron construction. All Jotul stoves and fireplaces
are made of 100% durable cast iron. Cast iron is the best
material to use because it can withstand more heat, and
is less likely to fatigue than sheet metal.
#8 Ivory Porcel~n Enamel
#8 CLEARANCES TO COMBUSTIBLES
TOP EXIT WITH ELBOW
TOP EXIT STRAIGHT THROUGH ROOF
#8 Black Senotherm finish with short legs.
JOTUL USA, INC.,
EO. Box 1157, Portland, Maine 04104
1. GENERAL INFORMATION
1.1. The Jotul Fireplace Stove 8 is made of cast iron and Is
designed to burn both wood and coal as fuel. Logs ap-
proximately 20 inches in length may be used and the
stove may be filled with approximately 18 lbs of wood.
When using the Jotul 8 as a coal burning appliance the
optional coal burning grate must be used. Both nut
size anthracite and bitumious coal may be burned.
The Jotul Fireplace Stove 8 may be used either as an
open fireplace or closed, as a room heater. When using
the stove as a room heater, the heat output is regula*
ted by the sir inlet valve located on lower front of the
door.
1.2. When installing, operating and maintaining your Jotul
Fireplace Stove 8 follow the guidelines given in these
instructions. Save these instructions and keep them
so that they are always available to anyone using the
stove.
2. HAZARDS CONNECTED TO THE USE OF THE J~TUL
FIREPLACE STOVE 6
2.1. Any use of fire, even with the door of the flreptace
closed represents e usrtain danger.
2.2. With intense firing the temperature of the cast iron can
exc~eed 500° C (932° Fl. The following factors must al-
ways be considered.
A. The stove should not be installed in areas of the
room where there is traffic.
B. Loose inflammable material must kept a safe di-
stance away from top end front of the Fireplace
Stove, a minimum 90 cm (36 inches).
C. Children must be taught that the stove is hot and
must not be touched.
--- D~ Clothes must notbedded~)ver the stove. They-can
fall down and be ignited.
E. Contact Local Building or Fire Officials about Re-
strictions and Installation Inspection in your area.
F. The Jatul Fireplace Stove 8 must be used and main-
tained in accordance with these instructions.
2.3. Never use the stove if there are combustible gases in
the room.
2.4. Poisonous gases can come out of the stove into the
room, if, for example the ventilation system creates a
Iow pressure condition in the room where the stove is
located.
2.5. Make sure that the sparks and embers do not get out
of the stove when the door is open. The spark screen
must always be used when the stove is operated as an
open fireplace.
2.6. Disposal of Ashes
Ashes should be placed in a metal container with a
tight fitting lid. The closed container of ashes should
be placed on a noncombustible floor or on the ground,
well away from all combustible materials, pending fi-
nal disposal If the ashes are disposed of by burial in
the soil or otherwise locally dispersed, they should be
retained in the closed container until all cinders have
thoroughly cooled.
2.7. Creosote-Formation and the Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture
to form creosote. The creosote vapors condense in the
relatively cool chimney flue of a slow burning fire. As a
result, creosote residue accumulates on the flue
lining. When ignited this creosote makes an extremely
hot fire.
If the creosote has accumulated it should be removed
2.8. Use solid wood or coal as fuel never use liquid fuels.
Liquid fuels utilized in a stove can result in an explo-
sion and fire.
Never use gasoline, gasoline-type lantern fuel, kerose-
ne, charcoal lighter fluid, or similar liqdds to start or
.freshen up. a fire in this fireplace stove, ~';eep all such
liquids well away from the fireplace stove while it is in
use. For your safety, follow these installation instructi-
ons. If this stove Is not properly installed, a house fire
may result.
2.9, Andirons may be used with the Jetul Fireplace Stove 8
to support the logs when burning wood. When burning
coal the optional coal grate system must be used.
3. INSTALLATION
3,1. Consult Local Building or Fire Officials about Restric-
tions and installation inspection in your area. For your
safety, follow these installation directions, If this sto-
ve is not properly Installed, a house fire may result. Re*
fer to the chimney and chimney connector manufactu*
rer's instructions and local building codes for Installa-
tion through combustible wails or ceilings,
3.2. Inspect your Chimney
The Jotul Fireplace Stove 8 must be connected to a
masonry chimney for residential type appliances, or
an Underwrlter's Laboratories, Inc. Listed Residential
Type and Building Heating Appliance Chimney, 7 inch
diameter. Single wall metal chimney shall not be used.
For a circular chimney, a diameter of a minimum 7
inches is required. The minimum height for the
chimney should be in accordance with the chimney
manufacturers instructions.
GO NOT G~NNECT-T-HIS UNtT TO A-CHfMNEY FLUE
~;'. SERVING ANOTHER APPLIANCE.
3.A. Installing the Jotul Fireplace Stove 8 into masonry fire.
place.
When installing the stove into a masonry fireplace the
following steps must be followed:
1. A direct connection must be made between the fire-
place damper area and the chimney flue through
which the connector pipe passes. Use a filler plate
of 12 guage Iow carbon steel to permanently seal
the fireplace throat below the chimney.
2. Install the adjustable Jotul fireplace shield to the
dimension of the fireplace opening. See Diagram A,
B and C.
3. Install the necessary floor protection in installa-
tions where it is necessary.
3.3. Determine where the Jotul Fireplace Stove 8 is to be In-
stalled.
The stove can be installed in different ways, but the
installation chosen must be in accordance with these
instructions. Figure I shows the listed installations
and the clearances which can be used.
Make a Floor Protector.
The stove must be placed on a floor protector of 1 layer
of 318 inch millboard having a thermal conductivity K
<: 0.84 BTU Inlft=.h.°F or the equivalent protection
provided by the use of UL tistcd floor protectors.
The Floor protection shall extend at leest 18 inches in
front and at least 8 inches to each side of the fuel load-
ing dopr and beyond the back of the stove.
Where the chimney connector exits the rear of the
stove the floor protector shall cover the area behind
the stove to the wall beneath the connector and extend
The floor protector may ne placed on [he sub og finish
flooring and shall be readily distinguish~l~'from the
surrounding floor
3.5. Installing the Flreolace~tove 8.
The Jetul Fireplace Stove 8 is completely assembled
at the factory with the exception of the 4 legs, door
handle, floor shield and a~h apron which are packed
inside the stove.
After installing the legs, the handle, the shield and ash
apron, using the fasteners provided, place your stove
on the protector according to the clearances to com-
bustible material given in figure 1. Clearances to com-
bustible walls may be reduced by using UL listed Wall
Shields. Refer to the wall shield manufacturers in-
structions for details.
3.6. Install the Chimney Connector.
With the stove in place you can now determine the
path of the chimney connector. The connector (stove-
pipe) shall be used to connect the stove to the chim-
ney. The connector shall be 24 gauge or thicker, black
or biued steel pipe. 7 inch diameter. The connector, for
its entire length shall be the same size as the smoke
outlet of the stove (7"). Each joint must be secured
with sheet metal screws to insure a tight joint and to
prevent accidental separation. Furnace cement may
be applied to each joint to insure a tight seal
The chimney connector is secured to the smoke outlet
by two 6 mm screws which are delivered wirh the
smoke outlet.
A connector to a masonry chimney shall extend
through the wall to the inner face of liner, but not
beyond, and shall be firmly cemented to the masonry.
A thimble may be used to faciliate the removal of the
chimney connector for cleaning, in which case the
thimble shall be permanently cemented in place with
A chimney connector shall not pass through any floor
or ceiling, nor through a fire wall partition.
3.7. Before Building a Fire.
With the chimney connector properly secured to the
chimney and the smoke outlet, your Jetul Fireplace
Stove 8 is ready to use. Please read the following
section carefully.
4. OPERATION OF THE J~TUL FIREPLACE STOVE 8
4.1. Always use solid wood or coal as fuel.
When burning coal, always use the optional Jetul
burning grate. Please see the section in these instruc-
tions marked ,Operation-Coal Burning~,.
4.2. Operating-Wood Burning
The wood fuel should be air dried for at least 4 to 6
months and covered in such a way as to be kept dry
while allowing a free circulation of air through the
wood.
4.3. Firing with Closed Door
Open fully the draft regulator located on lower front of
the door. Crumple a quantity of paper and place a qu-
antity of dry kindling randomly on top of the paper mid
light. Once this kindling has caught, add more kindling
and close the door leaving the draft regulator fully
open. After a short interval begin adding normal size
pieces. Allow these pieces to -catch,, and burn strong-
ly for a short interval.
The fully open draft regulator should now be adjusted
to regulate the heat output of the stove to the desired
In place of constant rekindling, the stove may be :.'apt
burning continuously day and night. When the wood
has burned almost completely and only embers re-
main, new fuel should be added and the draft regulator
opened fully. The new Icad of fuel should be allowed to
ignite and burn well for a short period of time before
adjusting the draft regulator to desired level of heat
output.
4.4. Firing with Open Door
When firin{3 the stove as an open fireplace follow the
same procedures as above in regards to lighting the
fire. At the beginning of a fire, the draft in the chimney
may be poor. To prevent smoke being released into the
room, close the stove door and fully open the draft
regulator. After the chimney has become warm and the
draft has improved, the door may be opened and the
spark screen put in place. Always use the SPARK
SCREEN when operating the stove as an open fire-
place.
WARNING-FIREPLACE STOVES EQUIPPED WITH
DOOR(S) SHOULD BE OPERATED ONLY WITH
DOOR(S) FULLY OPEN OR DOOR(S) FULLY CLOSED.
iF DOOR(S) ARE LEFT PARTLY OPEN GAS AND
FLAME MAY BE DRAWN OUT OF THE FIREPLACE
STOVE OPENING, CREATING RISKS FROM BOTH
FIRE AND SMOKE.
For your safety, follow these installation instructions.
If this stove is not properly installed, a house fire may
result.
4.5. Operation-Coal Burning
DO NOT BURN COAL WITHOUT GRATE.
Operation of the Jetul Fireplace Stove 8 with optional
Jetul Coal Grate
To install coal grate:
1. Remove top of stove.
2. Remove top of baffle plate.
3. Place sliding shaker grate inside grate bearer.
4. Place assembled grate system inside stove and fit
on to shelf located on the inside burn plates, Both
side burn plates have pins which fit into the grate
bearer which secures the coal grate system and in-
sures its proper installation.
5. Install the ash pan beneath the coal grate. A tool is
provided to shake the grate and for removal of the
ash pan.
6. Replace the baffle plate.
7. Replace top plate.
Lighting a coal fire:
Establish a hot wood fire and allow it to burn until it
becomes reduced to a large glowing bed of embers.
Add a layer of coal about 2 inches deep. Close door
and fully open draft regulator. Allow coal to ~catch,
and burn until glowing. Add more coal. Adjust draft re-
gulator once fire is established, to desired heat output.
THIS STOVE IS INTENDED TO BURN NUT SIZE AN*
TRACITE AND BITUMIOUS COAL.
4.6. Fireplace Stoves must not be fired to extent that they
assume a red glow. If they are atlowed to do so the
castings and enamel finish may then be damaged. DO
NOT OVERFIRE. iF FIREPLACE STOVE OR CHIMNEY
CONNECTOR GLOWS, YOU ARE OVERFIRING.
For your safety, follow these installation instructions.
If this stove is not properly installed, a house fire may
4.7.
During the first few times you use the new stove, the
stove may become somewhat damp. In order to prevent
this condensate from running down the sides of the
stove, open the door slight{y during the first firing. As
soon as the stove is warm, the condensate will ecapo-
rate and the door may be closed. A bottle of black Se-
notherm is enclosed for unenamelled room heater. It
may be used for touching up possible scratches in the
finish. Color touch-up paintfor enamelled stoves is
available through your Jetui dealer.
On enammelled fireplace stoves, this condensate sho-
uld be wiped off immediately, as it will permanently
stein or pit the surface.
5. SWEEPING AND MAINTENANCE
5.1. When wood and coal burns, soot and creosote may
develop and could together with other uncombustible
particles settle in the chimney and the chimney con-
nector. If these deposits increase, it may be necessary
to have them removed, this must be done by sweeping
the chimney and chimney connector regularly. How
often depends on the use of the stove. As a rule, the
chimney connector and chimney should be inspected
at least twice monthly during the heating season to de-
termine if a creosote build up has occured.
If the chimney and chimney connectqr is not swept
regularly, e chimney fire may develop. If a fire should
erupt, the chimney should be inspected by a professio-
nal before using again. For your safety, follow these in-
stallation instructions. If this stove is not properly in-
stalled, a house fire may result.
5.2. The Jetul Fireplace Stove 8 may burn .continuoosly.
(day and night) even on small Ioeds. Should pitch
develop, during such continuous burning conditions
the fire+place stove should be fired intensely at the
beginning ~ eac~h I~oading, on regular basis. This
method of operating the st~ee w~!l[ help to reduce the
buildup of creosote.
When sweeping the chimney connector it may be con-
venient to disconnect the stove. The chimney con-
nector must be cleaned in its fullest length to assure
safe removal of all creosote which has condensed on
the inner surface.
Be sure to install the chimney connector properly after
sweeping and secure it with the screws used at the
joints.
Disposal of Ashes (See 2.6.)
Maintenance
We recommend that you inspect your stove whenever
sweeping is performed. Check all visible surfaces for
cracks. Inspect the joints for visible leaks and check
the gasket in the door and on the top lid. Loose gas-
kets may be repaired by applying some water glass
(sodium silicate) to the gasket groove and pressing
the gasket back into the groove. Allow to dry before
using again.
6. OPTIONAL EQUIPMENT
The following optional equipment is available for the
Jetul Fireplace Stove 8. P~ease follow the instructions
supplied with each of the optional equipment pack-
ages.
1. Short Legs catalog number 350074
2. Coal System catalog number 350072
3. Fireplace Shield catalog number 350073
FLOOR FLUE OUTLET T1 T2 I T3
PROTECTION NUMBER OF LAYERS 1 t ' 1
//
B 35" 35" 35'
LAYERS OF 3/1 iNCH MIL~BOARD WHERE
C 34 1/2' 34 t/2' 341/2"
Fig. 2