Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33804-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEP~RTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33571 Date: 02/27/09 THIS CERTIFIES that the building RECONSTRUCTION Location of Property: 135 SUNSET LA GREENPORT (HOUSE NO.) (STREET) (HAMLET) County Tax,lap No. 473889 Section 33 Block 4 Lot 48 Subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 2, 2008 pursuant to which Building Permit No. 33804-Z dated APRIL 9, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued ~s ONE FAMILY DWELLING WITH FRONT COVERED PORCH, REAR SECOND FLOOR DECK AND ATTACHED ONE CAR GARAGE AS APPLIED FOR. · ~ne certificate is issued to ROBERT JR & GAIL A GHOSIO (OWNER) of the aforesaid building. COUNTY DEPARTMENT OF NEALTH APPROVAL gLgt-ialCa5 <mTIFICATE NO. I~LI~BERS CERTIFICATION DA'r~v Rev. 1/81 N/A 4008070 12/15/08 12/10/08 BD-RTS RELI~LE INC //u~rize~ Signature Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This applicat~n must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval ofenmpleted site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Acenrate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: [, Location of Property: House No. Street Owner or Owners of Property: C {4 Suffolk County Tax Map No 1000, Section Subdivision Permit No. '~,~ Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ _~, Old or Pre-existing Building: Date ofPermit. ~-~ lq lo. (check one) W Block 2-~ Lot Filed Map. Lot: Applicant: ~--~ /"~)~ ] 0 Underwriters Approval: Final Certificate: (check one) Applicar~ignature 53095 Main O. 8o~ 1179 New Yolk Fa~ (5~0 7,3!, '~' OFFICE OF 'THE BUILDING INSPECTOR TOWN OF SOUTHOLD Building Permit No, Owner: CERTIFICATION (please print) Date: - (please print)-' I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. ~\ ~ (plumbers Sworn to before me this I0)'I'K day of 0~c6¢05'f/' 20 08' Notary Public, .(J~2~ccC~.k. County BERNADETTE L. TAPUN NOTARY Pd8LIC ~4~44893 Stato of New York R'~¢ding i~ SufL',!, k County Cot'Expires ~__ BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by PECONIC ELECTRIC CORP BOB GOSHIO P.O. BOX 1258 .. 35 SUNSET LA QUOGUE, NY 11952, GREENPORT, NY 11944 Located at 35 SUNSET LA GREENPORT, NY 11944 AppLication Number: 4008070 Certificate Number: 4008070 Section: Block: Lot: Building Permit: 33804 BDC: NS37 Residential wherein the premises electrical system consisting of Described as occupancy, electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Attached Garage, Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard of New york, Department of, State Code Enf.(~rcement and Administration, or other promulgated by the State authority having jurisdiction, and fou'~d to be in compliance therewith on the 15~h D~ bf December, 2008. Name QTY Rate Rating Circuits Type AFCl 3 0 Dimmer 20 0 120 V Fixture 8 0 Fluorescent Fixture 23 0 Low Voltage Fixture 69 0 Incandescent GFCI Circuit Breaker 9 0 Lighting Track 10 0 ft Outlet 100 0 Fixture Outlet 126 0 Gert, Purpose Paddle Fan 7 0 Receptacle 3 0 GFCI Receptacle 90 0 Gert, Purpose Switch 76 0 Gen, Purpose seal 2 of 2 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33804 Z Date APRIL 9, 2008 Permission is hereby granted to: ROBERT JR & GAIL A GHOSIO 135 SUNSET LANE GREENPORT,NY 11944 for : RECONSTRUCTION OF AN EXISTING SINGLE FAMILY DWELLING FOLLOWING FIRE DAMAGE, AMENDMENT TO ORIGINAL EMERGENCY DEMO PERMIT. at premises located at 135 SUNSET LA County Tax Map No. 473889 Section 033 pursuant to application dated APRIL Building Inspector to expire on OCTOBER Fee $ 1,375.20 GREENPORT Block 0004 Lot No. 048 2, 2008 and approved by the 9, 2009. ~ze/~~~ mature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [~/~INSULATION [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION FINAL FIRE SAFETY INSPECTION FIRE RESISTANT PENETRATION REMARKS: TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 [ ] FOU N~ATINoNSIsTP E C R~OUG HOpLNBG. [ ]F~JNDATION2ND [ ]INSULATION [1/JFRAMING/STRAPPING [ ]FINAL [ ] FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION [ ] FIRE RESISTANT ~C~./~UCTION [ ]~FIRE RESISTANT PENETRATION DATE rn:,l D INSPECTION REPORT I DATE FOL~DATION (2ND) ROUGH FK~G & .... // . ~ ' / ~DITION~ COUNTS - JAMES J. DEERKOSKI, P.E. 260 Deer Drive Ma~lituck, N.Y. 11952 (631) 298-7116 Date: To: Re: September 2, 2008 Tovm of Soufl~old Strapping/Firestop Inspections Ghosio 135 Sunset La. Greenport, NY Pemfit#33804 To Vv'hom It May Concern: This letter certifies that all wind strapping on the above mentioned project is in tact, and meets all state and local building codcs. Also The Fire Stops in the Front Porch Ceiling were installed correctly. Any questions please feel free to call. ~x Sii~erely,. Ceerkos Date: To: Rc: JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-5506 June 5, 2008 Town of Southold Building Dept Foundation Inspection Ghosio 135 Sunset La Greenpo~,NY Pcmff~33804 To Whom It May Concern: Tiffs letter certifies that a tboting, foundation, damp proof inspection was preformed on the above mentioned property and was all done correctly and meets all state and local codes. Any questions please feel free to call. P.E. Permit # Permit Date REScheck Software Version 3.7 Release '1 b Compliance Certificate Project Title: Ghosio Report Date: 05123108 Energy Code: Location: Construction Type; Heating Type: Glazing Area Percentage: Heating Degree Days: Construction Site: 33 Sunset La Greenport, NY New York State Energy Conservation Construction Code Suffolk County, New York Detached '1 or 2 Family Non-Electric 10% 5750 Owner/Agent: Designer/Contractor: Ceiling 1: Flat Ceiling or Scissor Truss: Wall 1: Wood Frame, 16" o.c.: Window 1: Wood Frame:Double Pane with Low-E: Door 1: Solid: Door 2: Glass: Floor 1: Ali-Wood Joist/Truss:Over Unconditioned Space: Floor 2: Ali-Wood Joist/Truss:Over Outside Air: 1774 30.0 0.0 62 3088 13.0 0.0 227 186 0.350 65 21 0.290 6 112 0.340 38 1748 19.0 0.0 82 26 30.0 0.0 1 Statement of Compliance: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance with this Code. Builder/Designer Company Name Date Ghosio Page 1 of 4 REScheck Software Version 3.7 Release lb Inspection Checklist Date: 05/23/08 Ceilings: [] Ceiling 1: Flat Ceiling or Scissor Truss, R~30.0 cavity insulation Comments: Above-Grade Walls: [] Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [] Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Doors; [] Dcor 1: Solid, U-factar: 0.290 Comments: Door 2: Glass, U-factor: 0.340 Comments: Floor 1: Ali-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: [] Floor 2: All-Wood Joist/Truss:Over Outside Air, R-30.0 cavity insulation Comments: Air Leakage: [] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ~1 Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance Eom combustible matedals. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented flamed ceilings, walls, and floors. Materials Identification: [] Mateflals and equipment must be installed in accordance with the manufacturer's installation instrucfions. [] Materials and equipment must be identified so that compliance can be determined. I~ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [] Insulation R-values and glazing U-factors must be cleady mad(ed on the building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [] Retum ducts in unconditioned attics or outside the building must be insulated to R-4. ~1 Supply ducts in unconditioned spaces must be insulated to R-8. [] Retum ducts in unconditioned spaces (except basements) must be insulated to R- [] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. · insulation is not required on return ducts in basements. Ghosio Page 2 of 4 Duct Construction: [] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-~mbedded-tabdc, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal jctnt~ and seams on ducts operating at less than 2 in. w.g. (500 Pa). [] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [] Separate electric meters are required for each dwelling unit. Fireplaces: [] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code. as applicable. Service Water Heating: [] Water heaters with vertical pipe dsers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Ghosio Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heatsd Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Range(°F) Insulation Thickness In Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Ghosio Page 4 of 4 Attachment: Application For Building Permit Robert Ghosio Jr. Gail A. Ghosio 33 Sunset La. Gmenport, NY 11944 4/2/08 Fire Date: 3/28/08 Scope of Job: 1. Demolish 2 story residence to the extent permitted by insurance company. 2na floor will definitely be demolished, 1st floor ceilings and walls may be demolished. Finished basement will be gutted. 2. Temporary electric to be installed on outside temporary pole. 3. Propane tank to be removed. 4. Rebuild of existing home will be in the same footprint as existing. Engineer's plans will be drawn ASAP and submitted for the file. 5URVE'r' OF PROPER'I"Y' 51TUATE: C~P~I=NPO~T TOi~IN: ~;~FFIOLI~ ..eUFFOLK ~"I'T', N'T' 5URVET~O 0~-25-200~, 04-10-200~ 5~FFOLK ~NT¥ tax # IOOO- ~- 4- 4~ ROBt{R.T A. OHOS10 GAlL A. OHOSIO BIII~H AMPTON NATIONAL BANK BRIIX]B ABSTRACT LLC N ZI NOTES: · HONUH~NT FOUNP /N"e~ -- 12~,~,~.0~ ~L' Fl:. OP. 0.2q4~ A~c~5 LOT NUNIBEtP..e, El'ER TO "MAP OI= EAS'rERN 5~ORE5 AT (SREENPOP..T" FILED API~.IL 2'-/, Iq~4 A~ FILE # 4021 ®P-.APHIC. SCALE I"= DO' JOHN C. EHLERS LAND SURVEYOR 6 EAST ~ STREET N.Y.S. LIC. NO. 50202 RIVERHEAD, N.Y. 11901 369-8288 Fax 369-8287 REF.-\\Compaqserver~prosVO0SVOS-133REDO.pro FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED} PERMIT NO. 33804 Z Date APRIL 9, 2008 Permission is hereby granted to: ROBERT JR & GAIL A GHOSIO 135 SUNSET LANE GREENPORT,NY 11944 for : EMERGENCY DEMOLITION OF AN EXISTING SINGLE FAMILY DWELLING DUE TO FIRE DAMAGE at premises located at 135 SUNSET LA County Tax Map No. 473889 Section 033 pursuant to application dated APRIL GREENPORT Block 0004 Lot No. 048 2, 2008 a/id approved by the Building Inspector to expire on OCTOBER 9, 2009. ORIGINAL Rev. 5/8/02 .TO~r~ OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork.net Examined Disapproved a/?~ [ PERMIT NO. ,20__ Expiration 20__ BUILDING PERMIT APPLICATION ,CHEC,KLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Surve3~ Check Septic Form N.Y.S.D.E.C. Trustees Flood pernut Storm-Water Assessment Form Contact: Mail to: Phone: APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of th/s application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. ' £ Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply ~vith all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applic t~name, if a corporation) (Mailin~ address of applZant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electr/cian, plumber or builder Nameofownerofpremises ~o~4-(-'-/L- ~-~O%,;~ -J(-. '~,q-~'/ /~-~-~-,~oSr~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Location of land on which proposed work will be done: S g SuN 5 e_-/-- L~-. House Number Street Hamlet Block Filed MapNo. County Tax Map No. 1000 Section ~'~ Lot t.J ~, Subdivision Lot 2. State existing use and occupancy of premises and intended use and occuCancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Repair Removal Demolition 4. Estimated Cost '~ fl._ff'O~ oOO Fee 5. If dwelling, number of dwelling units If garage, number of cars I Addition Alteration OtherWork t"eJ~,,, ),:,l 4:4re. (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height_ Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Depth Height. Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories Rear 9. Size of lot: Front 10. Date of Purchase Rear .Depth Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ~5~ 13. Will lot be re-graded? YES NO 7Will excess fill be removed from premises? YES NO 14. Names of Owner of premises ~ ~ C,~ C ~ . F~/~'~O Address 355-v~1~4'/~PPhoneNQ°q~L Name of Architect ' Address Phone No Name of Contractor 'Bo ~4 ~ race,eM Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ~ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ~ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO ~ff' · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) ..... ~-~O~t- ~1t~ <; t ~ Jr"~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the t~(.o 4 ¢ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this cC ('1~ .day of /'~ .~'! 201~_ Notary Public~ ~ / 8ERl4t;BkTtE L. lhPklll .5URVE'Y OF PROPERTY' 51TUATE~ NORTH OF THE INC,. VlLLAC~E OF ~REENPOR'I' TOHN OF 50UTHOLD 5UFT=OLK ~TY, N'r' GRAPHIC SCALE PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANGY CERTiFiGATIO~ c ,- NAILING & CONNE,-,TiONS GHO IO IDENC SOLDER USED IN ~ SU,OPL Y SYSTEM CANNOT EXCEED 2/10 OF 1% LEAD. APPROVED AS NOTED DATEi~ B.P.# 5'2~0L~''~''' 765-180B 8AM TO 4PM FOR THE CENTERLINE OF WrNDOW5 TO ALIGN, FI~.DT FLOOR WrTH SECOND FLOOR CENTERLINE OF WINDOWS TO ALIGN, FIRST FLOOR WITI-I SECOND FLOOR FOLLOWING INSPECTIONS: 1, FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2, ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.C. ALL CONSTRUCTION SHALL DEBT THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. UNDERWRffERS FRAMING UNTIL OF FOUNDATION L RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE, OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFL OF OCCUPANCY ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE cODES OF NEW YORK STATE, ooozo COMPIcY WITH CHAPTER FLooD DAMAGE PREVENTION SOUTHOLD TOWN CODE. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODE~ AS REQUIRED AND CO!,IDITIONS O[ N ZBA DWN PI.ANNING BOAR[ [OWN Tt~UBTEE8 FRONT ELEVATION h, = I '-O" 5CALE: ~ N.Y.&DEC BOUTHOLD BUILDING DEPARTMENT CF. ITEP-.IA OCCDPAMCY CLASSIFICATION R-3 REsrDE],ITIAL - 5EcTroN ~ I 0 ~UILDING CODE N TY?E OFX~,C~STRUCTIQ.f~ WOOD FRAME CONSTRUCTION DESIGN-- "':"~'~ C TKN~¢~I~.-.-~ __ N E !4/-"~~- ' ,f,, ~ ERESG RIPTIV~ D ~SlG f,I I ~95 HIGIfl WIND EDITION WFCM FRAMING ~¢]~I.~4~EE~,~,'~'~-'%,"~ SEE FLOOR PLAN5 AND SECTIONS PAGE: LEffT SIDE ELEVATION SCALE: ¼"= ILO'' 'AGE' 2 R. IGHT SIDE ELEVATION SCALE: ~ II II I~L~I~L ~IT il II ,IT IIIIII IIIJll PAG~. 3 I _~: !_- _- ~ 2 ~ !_- z ~_- z ~' ~~~ ,~ ~z~ u ~'~' ','~?, ~~11," ..~EL~~ C z III II II;I II I1~1 II UL II IILI II~L REAP-. ELEVATION -~_~ SCALE: ¼" = ILO'' ~LJ ~Z :*Z [''' z >o~?-. EXISTING CI~,WL 5?ACE TO REMAIN ~IDTING BASEMX ~x~RRA TO REMAIN 7~¢?ICAL ALLIAR~AS/c~'X~O EXISTING CRAWL SPACE TO REMAIN \ d ~fl D~JSL~ JOISTS UNDER ?f~O~/iDZ SEAM POCX~T IN -- ~__ OUTL b EXISTING CRAWL 5PACE TO REMAIN ALIGN PP, OVIDE SIM?SON LGUM2G-2 CONNECTOR DOLTED TO FOUNDATION WITH TITZN ND aa'' X 4" 50LT5 FOOTING NEW W/ 212" X G" ACQ D.J, J® IO"DONOTUBEW/POURED CONCRZTEFOOTING 2'O"X 2LO"X PO"d, ¢Y?ICALALLFOOTINGS) FOUNDATION PLAN 5CAKE' ~" = I' 0" OF FOUNDATrON WALL ¢FYPrCAL ALL AREAS) FOUNDATION WALL LEGEND: EXISTING WALL PAP, TITiON: USE ACQ ON ALL AREAS AGAINST r'"", z ~, ua >o X (.O(O .'1 PAGE' 5 BEDROOM ~EDGE OF SECOND FLOOR E,kff E RI 0 R WALL ABOVE MUD OVER SUDFLOOR BEDROOM 3' O"KNEE WALL -- WITH GLA.DS BLOCR ABOVE IN SHOWER FLUSH HD VINYL PAN CLOSET MADTER~ E, EDROOM EXISTING DOOR UNrT TO REMAIN J 2 I~"X I I~Z"LVLHEADER LIVING ROOM LOCATION5 OF ?05T5 ABOVE 4" X 4" POET ASOVE - WRAP WrNDOW ~DENCH SEAT FROVfDE LIFT UE TOE AND RAISED PANEL FRONT I~" X 9½" LVL DROPEED TEMF 9" X 4" PORCH PLO PORCH DINING AREA K, ITCHEN ' 5UPPORT E STAIR OUTLINE OF SECOND ELOOR AREA ABOVE o I 'OSTS ~r2 CLODET PROVrDE WALL I LAUNDRY ® UTILITIES %. GAPxAGE ~ 2- J ~"X 9 ½" LVL HEADER AE~OVE GARAGE DOOR ,~'-0" X 7'-0" DOOR FIP-,,DT FLOOR PLAN h, = I LO" SCALE: ¥ NOTE' FROVfDE WIRING FOR OVERHEAD GARAGE DOOR A5 PER MANUFACTURER SPECIFICATIONS IN ACCORDANCE WITH THE RESIDENTIAL ELECTRICAL CODE OF NEW YOPJ<. STATE WALL LEGEND, E×ISTING WALL TO REMAIN DE 2- I~"X 9½" LVL HEADEP~5 ALL WINDOW5 ¢ DOORD PAGE: DOWN DOWN, ILO'' DE ~ ¢ DECK INBULATED BTEEL CLOSET- GREAT ROOM 3- I¢"X 92&'' LVL FLUBH HEADER J7,4 12 CUBTOM FRAMELEBS BOOR ¢ ENCLOBU~ DRYER MUD OVER J CLOSET J (TYF, END BEARING) 3- 14~'' X S2" LVL FLUBH HEADER FIREPLACE MEDIA ROOM WINDOW BENCH 5EAT PROVIDE LI~ UP TOE AND RAISED PANEL FRONT 2 TO HOUSE FRAME WiTH ' 7112 5ADLE rNBTALL VINYL FAN BEDROOM I 3% LIGIflT G7% VENT 12'M 2 2"X 4" SUPPORT __ MULLrON BETWEEN 3 I~"X D½" WINDOWS (TYE ALL) OUTLINE OF PORCH BELOW 5ECOND FLOOR PLAN BCALE. {"= ILO" 12 ATTIO R- I 5 INSULATrON WITHIN WALL PROVIDE 2- I ~" x 7¼" LVL HEADE~ DOW5 ¢ DOOR~ OTHERWIBE NOTED ©? T <:~ZEn a_dS PAGE: 7 I 1 I ~: 2"x a" ~.~ I GAF 30 YEA[ ARCHITE~U~L ~ / ~ d ~ ~ ff~RIM~E~D * VALLEY~ i ~°wu~ ~oor c~c~ ~ 2 ~ I~"X I I~" LVL RIDGff I ' ...... ~ --~ ---~ ' ~ ' ~ ........... / ~N OUTLINE I I OUTLINE Or FI~T (~f~TIN~ TO ~MAIN) , I ROOP P~Md PLAN GA¢ SO Y~AR ARCHITECU~L M 0 t ~ , ~X~-- ~ d FELT OVB~ ~" CDX PL~OOD ~ 8 I I ~owu~ ~oor c~c~ ~ 2 P~SM AT CHIMN~ ~1 I INTE~dCTION I I [ I~"X I I~" LVL RIDG~ I I I I I I I I I j I I ...... F --~ --- ~ ' a~oc - ~ ........... ~ ~ 6o.c WINDOW AND DOOR SCHEDULE 5T ,UCTUR.AL WOOD ?ANEL5 flOP-, WIND-BOP, NE DEBP-.15 ?P-.OTECTION POP. WALL OPENING PROTECTION OE120 MEld 3-SECOND WIND GUSTS (MAXIMUM MEAN ROOF HEIGHT ~5') MULTIPLE SECTION ASSEMISLY: I/4" THICR BOLTS ~ 2' OC FOR PANEL 5PANS: 0 < 4'-0" WIDE SPAN 25/32" APA 5PAN P-,ATED 4&/24 SHEATHING GRADE PL~OOD (OV~LA~ A~OUND OPENINGS USE AC G~AD~ W/R COAT5 ~RIO~ ~AINT 2 ~DES, 4 EDGES UTILIZING VID~TION R~515TANT ANC~O~ HAWING A MINIMUM WITHD~WL CAPACI~ OF 490 WD DOUBLE HUNG 5,35 B,BB I 0 4 DOUBLE NUNG DOUBLE HUNG CASEMENT 5 SO J 0 4 DOUBLE HUNG 5 74 JO 43 20 5 CASEMENT J O 4 OVAL I 0 4 AWNING JO DJ IIPDSOGB FRENCH WD HrNGED 20 4 D2 ISPDGO~B FRENCH WD. SLIDEP-. 50 4 EXISTrNG UNIT TO REMAIN ALL WINDOWS TO BE INTEGRITY BY MARVrN, WOOD ULTREX SERIES, UNLESS OTHERWISE SPECrFIED WINDOWS TO HAVE TRADITIONAL STYLE, STONE FINISH LOCKS ~ HARDWARE AhID PULL EXTERIOR SCREENS DIVIDED LIGHT GRILLES TO MATCH EXISTING WINDOWS 40 2 40 3 40 7 SO I 27 (NEW) CALCULATIONS FOR WINDOWS BASED UPON EXPOSURE COEEPfCIENT I OWITH I IOmphBASICW/NDSPEED, ASPER MUST HAVE DP UPGP~,DE KIT, MEETS NY STATE EGRESS REQUIREMENTS FOR HABITABLE SPACE. CUSTOM GRILLES - SEE ELEVATIONS WALL OPENINGS INCLUDrNG WINDOWS AND DOOR5 SHALL BE ?ROTECTED WIT[I REMOVEABLE 5/B" WOOD STRUCTURAL PANELS WITH MAXIMUM OF dS' 0" SPAN. FASTENEP~5 FOR 5PAFI5 UP TO G'-O" SHALL BE 2 I/2 - ~ ~ WOOD SCREWS AT I G" O/C, FASTENE~ ALTERNATIVE FOR OPENING PROTECTION WOOD STRUCTURAL PANELS Wfflfl A MINIMUM TH ICKNESS OP ?/J G" AND MA.glMUM PANEL SPAN OP D~ALL B~ F~EMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS. PANELS SHALL DE PRECUT TO COVER GLUED OPENINGS WITH ATTACHM[NT HA~D~AR[ PROVIDED. REFERTO SECTION I GO9,1 .4 AND I GOD G 5 AND TABLE I GO~ I TABLE 1 0 .1.4 W[NDBO~NE DEBRIS P~OTECTION F~TENING ~CH~DULE FOR WOOD 5T~UCTU~L PABIEL~ A~ACH ED UTILIZING ~~~~;AVING A MINIM UM W~ D~WL PAGE: 9 DESIGN LOAD CALCULATIONS I TABLE R,SO I .G ALLOWA~%E DEFLECTION OF BTRUCTURAL MEMEDER5 5TRUCTUR, AL MEMBER` ALLOWABLE DEFLECTION CEILING/pLATE HEIGHT 2 CEI ROOF 4"¢ ROOF VENT LAUNDRY C.O~ o~ TRAP SLOPE" 1/4" PER FOOT PITCH TO PLUMBING DIAG M NOT TO SCALE ATTIC SECOND FLOOR FIRST FLOOR BASEMENT 2" X 4" C.T. _ @ IG" 0 C. 2 I 4~"x 7¼" HEAUE,~ASOVE TO HOUBE FRAME WITH 5" ON PORCH pOP. CH POBTB-- H4 2" X ] 0" ~LDGE A~IC GAF 30 YEA~, IITECTURAL ABPHALT ROOFING WITH I 5# FELT OVER 4z'' CDR TLYWOOD WITH ICE ~ WEATI-IER SHELLS FROVIDE 2- I i"x ¢ ~" LVL DROPPED HEADER ~, DEBT-.DOM ~,, DYPSUM BOARB ~PICAL ALL ABRA5 2" x 4" STUD PA~TITrON P R.OVID~ CONTINUOUB BLOCKING ABOVE WALL KITCHEN ~" GYPBUM BOARDN DINING 24" X 24" X I 2" POURED CONCRETE FOOTING BYP ALL) 4" POURED CONCRETE BLAB ON COMPACTED TILL. MATCH BLAB FLOO~ HEIGHT BASEMENT 51MFSON H7 ONNECTOR FASCIA WITH , SOFFIT EXISTING WALL CRAWL BPACE TO REMAIN BUILDING SECTION "A" SCALE: ¼"= ILO'' TO SUFFOLK COUNTY DEF EALTH SEWER LINE ;LIMATIC AND GEOGR,APHIC DESIGN CR,ITER'IA MODERATE TO HEAVY 5LIGHT TO MODERATE NTER DEDIGN TEMP, J CE BHIELD UNDER- REQUIReD 5 PER MANUFACTUiRER'5 ZATION5 / STATE CODE 'AGE' I0 JOINT DESC ~.IPTION NAIL 5PACING NAIL QUALITY TOE NAILED ~'-O"WALL 3 WEND P-. 515TANT CONSTP-.UCTION CONNECTOP.5 CONNECTION LOCATION: PART NUM[bER~ NOTES: RIDGE-TO RAFTERS AFPLYTO EACH PAIR, OF RAPTERS 2ND FLOOR WALL TO- ] ST, FLOOR WALL HEADER-TO JACK STUD CRIPPLE 5TUB-TO HEADER, 0520 ~ 16" APPLY TO EACH WALL STUD APPLY TO EACH JACK STUD APPLY TO EACH CRIPPLE STUD SHEAR WALL NOLDDOWN ANCHOR SSTD I G APPLY TO EACH SIOEWALL END WRAP UNDER DOU~SLE SILL PLATE I 5T FLOOR-UNDER-51LL pLATE LFT4 (USE WITH 3" SQUARE WASHERS) TABLE 3.4 P-.OOF P. OOP NUMBER PITCH BPAN (ft;) NA LB 4.1 5.12 2O 24 2O 24 20 24 32 2C 24 WALL 51UO BOTTOM pLATE CONSTRUCTION DETAILS ¢ W1ND LOAD PATH CONNECTION DETAILS NOT TO SCALE GENERAL WIND PROTECTION CONNECTION NOTES Adapted Prom Standard for Humcane P,6sis~an6 ReSlden~lal II GENEP-.AL NOTES: intent and framing details. They are intended as a construction aid, not as a substitute for gerlerally accepted good Building practice and are in compliance with current New York 5tats bulldmg codes. The general contractor ~s responsible for provldln0 standard construction detalia and procedures to ensure a professionally finished, structurally 5ound and weatherproof completed product. · General contractor to coordmate all subcontractors, scheduling of work and interaction between trades. · The contractor is responsible for ensunng that all work and construction meets or exceeds current federal, state and local codes, ordinances and regulations, etc. The~e code5 are to be considered as part of the speclflCabons for this building plan. · If In the course of construction, a condition exists which dlsasreea with that aa mdlcated on these drawings, the contractor shall stop work and not~fy the designer $ the engineer ~mrnedlately. Should he fad to follow this procedure and continue work, h8 sllall assume all responsibility and Ilablhty arising therefrom, · Dimensions take precedent over scale - DO NOT SCALE DRAWINGS, responSlblhty for construction coordinating with these plans, nor responsibility for warranties for a specific use expressed or implied in the uae of these plans, · Contractor to provide hardwlred smoke detectors, with battery back up, and w~th no intervenmg switches, on all floors and m each bedroom. Verify with local code requirements as per Section P~ I 7 New York 5tats Residential Construclton Code. Install carbon monoxide de~ectors as per code. FOUNDATION NOTES: General contractor to review plans, elevations and details to determme intended height5 of fmlshed floor above typical grade. Concrete shall be PC = 3,500 PSI ~ 28 days Concrete on 4" sand or gravel fill minimum, with GxG - i O/I 0 welded wire mesh reinforcement. Interior slab5 to be placed on ¢ mil. stabilized polyethylene vapor tamer. Welded wire mesh is to be placed in 6he top third of the slab and ~s to be adequately supported by ?recast concrete bar supports to assure that the reinforcement is held in position durmg concrete placement and flnlshlneJ, · Isolation joints are to be installed between the slab and the walls. Use preformed joint filler that is to be cut I/2" below the 51ab surface and the resulting joint is to be filled with an elastomenc joint sealant. · General contractor to mstall cop-r-rex ( or copper) sheet metal termite shelld5 between all wood surfaces that are exposed to concrete or masonry surfaces. Dampproof exterior oF foundabon wall w~th a bituminous coatlnej; Foundation excavation ia not to be backhlled prior to the installation of the floor framing. PLUMBING ¢ HVAC NOTES: · All plumbing work shall be done by a duly licensed plumber and must co~form and adhere to all New York 5tats building codes ¢ sa~ey requirements. · If wall plates or joists are cut during the mstallatlon of plumbing fixtures or equipment contractor must provide appropriate bracing to be framln~ back together, Baseboard heating ia to Be hot water and zoned PlumbmeJ contractor la to adequately size the system and place the baseboards in an unobstructlve location in each room required to recleve heat. Minimum of one thermostat for 8ach zone will be required, · Mechanical subcontractor ia responsible for adhermg to all apphcable codes and saftely requirements, ELECTRICAL NOTES: · All electrical work to be BOARD OP PIR~ UND~RWRITER$ approved and to include installation of fixtures $ specifications aa indicated on plans. Light fixtures to be supplied by owner and installed by contractor. GFI outlets required at bathrooms and exterior areas, install all outlets aa per code All work is to be done in street accordance with the New York 5tats Code by a licensed electrician. All new switches ¢ outlets to be Levlt~on, s~andard, supplied ¢ installed by contractor, Contractor to do all hook-ups aa required for bathrooms FRAMING NOTES: All wood frammg in contact w~th concrete or masonry IS to be pressure ~reated. 'ACQ' destonat~on refers to current arsenic-free treated wood standards and shall take the place of 'CCA' · All TJl's are to be msballed in accordance with the manufacturer's specifications and shall include squash blocking web abffeners at Bearing points on g~rders and other load bearing areas · Structural 5tee[ ASTM A3~ - FY = 3G K,SI · All 5traps, connectors, plates, bolts, nails, etc. are to be galvanized. Designated connectors, straps. etc. on these drawings are my by 51mpaon unless otherwise indicated. All connectors, abra?s, etc. are to be nailed/bolted in accordance with the manufacturer's specifications, All floor sheathing 15 to be ~" AC type plywood, tongue ¢ groove and shall be glued and screwed to ~he floor jo~sts (6" o.c. edge5 ¢ 12" o,c, field) · 5olin blocking is to be installed every 8'-0" max. or mid span o¢ all floor joist5 with spans exceeding 8' 0". Blocking is to be moral[ed at all point load beanng points Install double joists under all partitions runnln~ parallel All exterior wall headers to be 2- LVL's a5 indicated on floor plan5 ¢ sections and all Interior headers are to be 2- 2" x 8" unless otherwise noted, All headers exceedmcj 5'-0'" 5hall have a double jack stud with a single king stud ¢ orl exterior walls prowde double 5~1[ plate (typical). · Provide insulation baffle5 at cave vents between rafters and soffit vents as md~cated on plans · Exterior flaahmg is to be adequately ~nstalled at all connections beeween roofs, walls, chimneys, projections and penetrations as required by approved cons~rctlon' practices. FLOOR PLAN NOTES: Dimensions shall take precedent over scale drawings, DO NOT 5CALE DRAWING5 · All ~nterlor wails to be covered w~th ½" gyspusm board with metal comer remforcmg, All drywall products, mcludmeJ gypsum board, screw, jOlr~t compound, tape5 ¢ trim shall be U.5. Gypsum Co. or approved equal, All jomts shall rec~eve ~ coa~s o~ joint treatment, 5and final coat to a uniform smooth surface. All walls, ceiling and interior of closets to be taped and spackled, 3 coats, ready for paint. · Walls common to garage and house to have a layer of e~'' fire rated gypsum board at garage aide w~th 5'-0" return on adjacent walls ¢ ce~hng. Provide 2 layers of ~" fire rated qypsum board on all enejlneered lumber aa required by manufacturer specifications · All bath ¢ kitchen area walls and celhnga adJaCent to wet areas to have water resistant drywall, and provide wonderboard for all areas set to recleve PAGE: 12