Loading...
HomeMy WebLinkAbout33942-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEP~=RTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-33545 Date: 02/13/09 THIS CERTIFIES that the building FARM STORAGE BUILDING Location of Property: 25 SOUND AVE MATTITUCK (HOUSE NO.) (STREET) (HAMLET) Co%unty Tax Map No. 473889 Section 120 Block 1 Lot 1.3 Subdivision Filed Map NO. __ Lot No. -- conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 19, 2008 pursuant to which Building Permit No. 33942-Z dated MAY 30, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is 60' X 195' F~=RM STORAGE BUILDING. The certificate is issued to HARBES FARM RHD EAST LLC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEP~/~TMENT OF HEALTH APPRO~-AL EI~C~fRICAL u~KTIFICATE NO. N/A N/A N/A Rev. 1/81 , Form No 6 , . · TOWN OF SOUTHOLD Bum m m:v mmENT_ Ttus a hcat~on must be APPLI~.ATION FOR CERTIFICATE OF OCCUP~Cy ' pp ' ' filled in by ~pewriter or i~ and submitted to the Building Depamnent with the following: A. For new bmlding or new use: 1. Final su~ey of property with accurate location of all bnildings propemy lines, streets, and unusual natural topographic features. 2. Final Approval frmn Health Dept. of water supply and sewerage-disposal (S~9 fbnn) 3, Approval of electrical installation from Board of Fire Unde~fiters 4. Sworn statement fi'om plumber ceaifying that the solder used in system contains less than 2/10 of 1% lead 5. Coimnercial building, industrial building, multiple residences and similar buildings and installations, a cel~Jficate of Code Compliance fi'om architect or engineer responsible for the building. 6. Submit Planmng Board Approval of completed site plan ~equirements B. For existing buildings (prior to April 9, 1957) non-couforming nses, or buildings and "l)re-existing" land uses: I Accurate suiwey of piopc~)' showing ali propelty lines, stieets, build ~g and uimsual natural o~ topographic featm es. 2 A pioperly completed applic~li(m and consent lu in:si)cci sigamd b3 the applicant den/ed, thc Building h~specto~ shall state the ~aasons Ihe~efcn in writing to d~e applicant C. Fees Ccrtificale of C)ccui)anc~ Ncu' du elliuf, $?5G ~, 'xdditions k~ clwelling $2500, Xl/clalioll:; 1() chvdhng $25 00, 2 Ce:ificateofOccul:mC,~.onlqe existmglBnilding $10000 3 Copy of Certificate ot Occul)anc}- $25 4 LlpclatedOe~lilicatcofOccul)anc5, $5000 5 Teml)o~ary Cmtificate: ,ff()ccup racy - l<esidentiM $1 $ ()0 Corm ]ec I S15.( ( New (~onstm~t~on: ~ Old o~ Pm exisdng Building: (chFck one) [louse No Street ~ Hamlet . Owner or Ow ~e's flhol)erlV ~ .~ ~ ' ~ ( Subdix Filed Map. Heald~ I )ept App~ oval ~ ~ [ h~de~,,n~el s Appmx al Final Ccrlificate: (check t ~e) Applicant Sigmature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33942 Z Date MAY 30, 2008 Permission is hereby granted to: HARBES FARM RVHD. E. LLC 25 SOUND AVE MATTITUCK,NY 11952 for : CONSTRUCTION OF A 60'X 195' FD~RM STORAGE BUILDING PER PLANNING BOARD APPROVALS AS APPLIED FOR at premises located at 25 SOUND AVE MATTITUCK County Tax Map No. 473889 Section 120 Block 0001 Lot No. 001.003 pursuant to application dated MAY 19, 2008 and approved by the Building Inspector to expire on NOVEMBER 30, 2009. Fee $ 150.00 / Authorized Signature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork.net PERMIT NO. ~.~ q~- -t~ Examined ~'/,.Z !~L~ Contact: Approved ,20 ~ ~ Mail to: Disapproved a/c Phone: Expiration / BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Planning Board approval Survey_ Check Septic Form N.Y.S.D.EC. Trustees Flood Permit Storm-Water Assessment Form APPLICATION FOR BUILDING PERMIT Date ~/// ,20 aK INSTRUCTIONS a. This apphcat~on MUST be comp!~tely filled ~n by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, ac&rate plot plan to scale. Fed accor&ng to schedule. b. Plot plan showing location'of !ot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, ifa corporation) /,o ,y,¢ /r 2. 7 //?//g£ Z (Mailing address of' applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises ,X/'~4.~/_,_ ~ A~/~/t~,d ~/ Z~'Z' (As on the tax roll or latest deed) If applicant is a corporatiog~,signgtmre of duly authorized officer (Name and titl~ ~f co~orafe officer) ~ / ..... Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which.proposed work will be done:.'., House Number Street Hamlet County Tax Map No. 1000 Section /Z ~ Block ~,' Subdivision Filed Map No. Lot /. ~-~ Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building_ Repair Removal 4. Estimated Cost /,~d~ d'Jg? Fee If dwelling, number of dwelling units If garage, number of cars 5. J Addition Alteration Demolition Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor ~ 8. Dimensions of entire new construction: Front Height ~q ' If business, commercial or mixed occupancy, specify nature and extent of each type of use. ~ Dimensions of existing structures, if any: Front ~- Rear ~ Depth Height /'~ Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth / Height J Number of Stories ~-~ o/~ ' Rear ~'~ .Depth Number of Stories / 9. Size of lot: Front 35>? ' Rear ~'2 ' 10. Date of Purchase 2z~52,~ Name of Former Owner 11. Zone or use district in which premises are situated ~z~/'d,~o~4~ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ Depth 2 q q 7 NO 13. Will lot be re-graded? YES__ NO t/Will excess fill be removed from premises? YES NO / 14. Names of Owner ofpremises_~_~e,~aa~_a-~&a- Address ~a.~~Phone No. Name of Architect Address Phone No Name of Contractor/".~)("/(S~./M,~ - ,,~//~-~/a-~./5'/t~. Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO / * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES · IF YES, PROVIDE A COPY. NO STATE OF NEW YORK) (~ SS: COUNTY o'l~l_ ('z~/~/-~4'~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, iTCont~ctor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perfom~ or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn t~before me this~-. Nota~ e~bl~ - ' NOTAR~'b~'~i~ State el New N0. 01D04634870 0ualified in Suffolk Coun~ ~o~ission ~iros September Signature of Applicant YOUNG & YOUNG 400 Ostrander Avenue Riverhead, New York 11901 Telephone 631-727-2303 Facsimile 631-727-0144 admin@youngengineering, corn HOWARD W. YOUNG, Land Surveyor THOMAS C. WOLPERT, Professional Engineer ROBERT C. TAST, Architect DOUGLAS E. ADAMS, Professional Engineer Mr. Edward Harbes Harbes Family Farm ]amesport P.O. Box 1524 Mattituck, New York 11952 February 4, 2 ~.~[" FEB !~ ?nOg )09 BLDG. DEPT. tow~ OF SOUmOLO RE: New Barn Lot 10 "Holly Farms" (Miscellaneous Map) at ]amesport, T/O Riverhead, New York (08-0396) S.C. Tax Lots 1000-120-01-1.3 & 600-003-0l-2.14 Dear Mr. Harbes: We have determined by actual measurement and do hereby certify that the barn recently erected on Lot 10, "Holly Farms" S.C. Tax Lots 1000- 120-01-1.3 & 600-003-01-2.14 is approximately 100 feet from the southerly and westerly property lines and approximately 253 feet from the easterly property line and said barn does comply with the minimum front, side and rear setback lines of the Agriculture Conservation (AC) Zoning Use District in which the premise is located. HWY/mal Encl. Very truly yours, Howard W.~fi~n~ng Planning Engineering Land Surveying Architecture TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FIREPLACE & CHIMNEY ] FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ]INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [/~ FOUNDATION 1ST [ FOUNDATION 2ND [ ] ROUGH PLBG. ] INSULATION DATE 7~ / ~ ~ O ~ INSPECTOR [ ]FRAMING / STRAPPING [ ] FINAL [ ]FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]FIRE RESISTANT CONSTRUC~I~ ON [], FIRE~RESISTANT PENETRATION RE~_ PLANNING BOARD MEMBERS JERILYN lq. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND November 3, 2008 Harbes Riverhead East LLC Att: Edward Harbes 715 Hallock Lane Mattituck, NY 11952 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave. ) Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 Re: Site plan for Agricultural Storage Building Dear Mr. Harbes: The Planning Board is in receipt of your request for final inspection dated November 3, 2008 for the above referenced application. As you requested, the Planning Board has inspected the site and has found that the work done to date is in accordance with the approved site plan. Any future requested change to the site plan should include a copy of the approved stamped site plan noting the location of the requested change. If you have any questions regarding the above, contact me anytime. Thank you. Sincerely, Kristy Winser Senior Planner CC: Planning Board Jamie Richter, Town Engineer Mike Verity, Chief Building Inspector FIELD INSI~ECTION REPORT I DATE ..................................... STATE ENERGY CODE ~DI~ON~ COUNTS - STATE OF NEW' YORK WORKERS' COk~ENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE TO: Edward Harbes PO Box 1524 Mattituck, NY 11952 FORM NO. 3 NOTICE OF DISAPPROVAL DATE: March 5, 2008 Please take notice that your ap~ date. ed.~d~F~ebm~_ary 11, 2008 For permit to construct of a gr&~da~rs~e and4~arh a~ Location of property: 25 Sound Avenue, Mattituck, NY County Tax Map No. 1000 - Section 120 Blockl Lot 1.3 Is returned herewith and disapproved on the following grounds: The proposed f~onstruction requires site plan approval from the Southold Town Planning Board. ~u~or~~~~re Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Planning Board PLANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND May 13, 2008 Mr. Edwah:LHarDes P.O. Box 1524 Mattituck, N.Y. 11952 PI~A~INING BOARD OFFICE TOWN OF SOUTHOLD MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 Re: Site Plan Approval for Harbes Equipment Barn & Greenhouses Located at 25 Sound Avenue, approximately 1,519 feet west of Aldrich Lane on the north side of Sound Avenue, 11165 County Road 48, Mattituck SCTM#1000-120-1-1.3 Zoning District: A-C Dear Mr. Harbes: The Southold Town Planning Board, at a meeting held on Monday, May 12, 2008, adopted the following resolutions: WHEREAS, the applicant, Edward Harbes, submitted a formal site plan application on March 10, 2008 for the construction of a new 60' x 195', 11,700 sq. ft. farm equipment storage building, and three hoop house greenhouses, 30'x 196', 5,880 sq. ft. each, on a 24.2 acre parcel in the A-C Zone located approximately 1,519 feet west of Aldrich Lane, on the north side of Sound Avenue, in Mattituck; and WHEREAS, on March 10, 2008, the Planning Board accepted this application; and WHEREAS, on March 17, 2008, the Planning Board, pursuant to Southold Town Code §280- 131 C., distributed the application to agencies having jurisdiction for their comments, and the following agencies responded: Town Engineer, Architectural Review Committee, Suffolk County Planning Commission, and the Mattituck Fire District; and WHEREAS, the comments from those agencies referenced above were received and accepted by the Planning Board, discussed with the applicant, and incorporated into the site plan to the satisfaction of the Planning Board; and WHEREAS, on March 28, 2008, the Southold Town Building Inspector reviewed the plan and certified that the proposed agricultural storage building and greenhouse is a permitted use in this A-C District; and WHEREAS, there is an easement restricting the use of the property to agriculture, held by the New York State Office of Parks, Recreation and Historic Preservation and the Suffolk County Agricultural and Farmland Protection Board, acting on behalf of the State, recommended approval of the proposed barn and greenhouses; and Harbes, Edward Pa,qe Two May 13, 2008 WHEREAS, the Southold Town Planning Board, pursuant to Southold Town Code §280-131 B.(5), has the discretion to vary or waive parking requirements. The Planning Board has found that waiving the parking requirements on this application will not have a detrimental effect on the public health, safety, or general welfare, and will not have the effect of nullifying the intent and provision of the site plan requirements chapter in the Town Code for the following reasons: the property is large relative to the size of the structures, few vehicles will access the site, and the site is not open to the public; and WHEREAS, the Southold Town Planning Board, pursuant to Southold Town Code §280-131 H., has the discretion to waive the public hearing requirement for those applications involving uses strictly related to agriculture. The Planning Board has found that the public hearing for this application may be waived for the following reasons: the application is for an agricultural use, the parcel is large in size relative to the proposed structures which will cover 2.8% of the property, and the structures will be situated in such a way as to be unobtrusive to the public view - located 100 feet from the nearest property line, and about 500 feet from Sound Avenue; and WHEREAS, the Southold Town Planning Board, pursuant to §280-133 C. of Southold Town Code, has the discretion to waive any or all of the requirements in §280-133 for those applications involving uses strictly related to agriculture. The Planning Board has found that requiring the entire set of site plan application requirements for this site is not necessary to further the objectives set forth in Town Code §280-129 and maintain public health, safety, and welfare for the following reasons: the application is for an agricultural use, and the parcel is large in size relative to the proposed structures; therefore, be it RESOLVED, that on May 12, 2008, the Southold Town Planning Board, pursuant to State Environmental Quality Review (SEQR) (6 NYCRR, Part 617.5 (c) (3), has determined that the proposed action is a Type II Action, and not subject to review under SEQR; and be it further RESOLVED, that the Southold Town Planning Board has reviewed the proposed action under the policies of the Town of Southold Local Waterfront Revitalization Program and determined that the action is consistent as outlined in the March 31, 2008 memo prepared by the LWRP Coordinator; and be it further RESOLVED, that the Planning Board hereby waives the parking requirements, public hearing requirement, and site plan application requirements, except for the following items: §280-133 A. (1), (2), (4), and (5), B. (1) (a)-(0, (h)-(j), (k-partial), B. (3) (a)-(b), B.(4) (a),(d), (f-partial) and (i- partial), and be it further RESOLVED, that the Southold Town Planning Board grants approval with a condition, listed below, and authorizes the Chairperson to endorse the site plan entitled "Map for Edward W. Harbes Ill", prepared by Young and Young, Land Surveyors, dated January 10, 2007, containing hand-drawn additions by the applicant, and a second drawing illustrating drainage. Harbes, Edward Pa,qe Three May 13, 2008 Condition: 1. All storm water run-off from grading, driveways and gravel areas must be contained on site. Please also note the following required by Town Code: 1. Any outdoor lighting shall be shielded so the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. 2. Approved site plans are valid for three years from the date of approval, within which time all proposed work must be completed, unless an extension is granted by the Planning Board. 3. Any changes from the approved site plan shall require Planning Board approval. 4. Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is in conformity with the approved site plan, and issue a final site inspection approval letter. Should the site be found not in conformance with the approved site plan, no Certificate of Occupancy may be issued unless the Planning Board approves the changes to the plan. Copies of the approved site plan are enclosed for your records. One copy will also be sent to the Building Department and the Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Very truly yours, dhouse Chairperson encl. CC: Southold Town Building Department w/map Southold Town Engineer w/map By signing this letter, the applicant acknowledges that there is a mandatory condition, listed above, in addition to the above listed Town Code requirements that must be satisfied prior to the issuance of a Certificate of Occupancy. Edward Harbesl Applicant N ACREAGE TYPE OF BUILDING fJ , RES. LAND Ti Lle~Je 1 Tillable 2 Tillable 3 Woodland Swampland Brushland House Plot SEAS. IMP. O~ ~NORMAL K-~ ~Acre TOTAL FARM :, DATE CONDI B ELO~W COMM. IND. REMARKS ,"~, z. ..T. L /9,L~,,,,,f Total M. Bldg. Extension Extension Extension Foundation Basement Fire Place Driveway Breezeway P' Garage ~C). B: · Porch Porciq Bath Floors interior Finish Heat \ttic Rooms 1st Floor Rooms 2nd Floor O~VNER ~-.,'/~ ~/,~~~ e~, FORMER 0~VNER / N/~/__?~, FARM .~ SUB. LOT TYPE OF BUILD'lNG CB. Mkt. Value DATE REMARKS. ~ Zlzco ~ Total Woodland I ~'~ ' "12;;.~ FRONTAGE ON ROAD Meadowbnd [ DEPTH House Plat i BULKHEAD Tillable Value Per Value Acre FRONTAGE ON WATER DOCK AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre COLOR TRIM M. Bldg. Extension Extension Extension Bo,th i Dinette Garage Type Robf Rooms 1st Floor BR. Patio Recreation Room Rooms2nd Floor FIN. B O.B. Dormer Driveway I Total ." Porch Basement Floors Porch Ext. Wolls Interior Finish Breezeway Fire Ptoce Heot i DR. ~-WNER - ~T--R~ ET VILLAGE DIST SUB LOT ACR REMARKS TYPE OF BLD. PROP. CLASS ~ ~ ' ' I ~ J ~ I O J LAND J I~. I /TOTAL DATE FRONTAGE ON wATE~ TILLABLE FRONTAGE ON ROAD wOODLAND DEPTH MEADOwLAND BULKHEAD HOUSE/LOT TOTAL TRIM 1 st 2nd PC M. Bldg Foundation CB Fin. B. Bath Dinette FULL COMBO Extension Basement CRAWL PARTIAL Floors Kit. SLAB Extension Ext Walls Interior Finish LR. Extension Fire Place Heat ¢ D.R. Patio Woodstove BR Porch Dormer Baths Deck Dock Faro. Rm, Garage OB. Pool Page 1 of 10 FOR: Harbes Agricultural Enterprises JOB # 128-0813 BUILDING USE: Agricultural Building BUILDING DESCRIPTION: WIDTH ..................................... BW:= 6(~fl LENGTH ................................... BL:= 195. f~ OVERHANG WIDTH .................. OW:~ EAVE HEIGHT .......................... EH:: ROOF SLOPE .......................... RS := 4/12 BAY SPACING ......................... BS:: ?.5. fl BUILDING CLASSIFICATION ...... BC:= '1' IMPORTANCE FACTOR ............ I:: 0.?? DESIGN LOADS: REFERENCED STANDARDS: ROOF LIVE LOAD ....................... LL:= 15. psf DEAD LOAD ............................... DL: 4. psf CEILING LOAD ........................... CL:= 0. psf WIND SPEED ............................. V~s := 120 mph EXPOSURE CATEGORY ............. EC:= "C' ENCLOSURE CLASSIFICATION... EnC:= "ENCLOSED" ASCE7-05 NYSBC2007 COLUMN CALCULATION: WI ~ EH= 15.5fl. W4 BW = 60fi ~ WIND DESIGN COEFFICIENTS: WIND DIRECTIONALITY FACTOR .................................................. 1~ := 0.85 3-SECOND GUST SPEED POWER LAW EXPONENT ..................... c~ = 9.5 NOMINAL HEIGHT OF THE ATMOSPHERIC BOUNDARY LAYER .... zo - 900 MEAN ROOF HEIGHT ................................................................... H: 20.5 HEIGHT ABOVE GROUND LEVEL (ASCE minimum) ....................... z = 20.5 VELOCI~ PRESSURE EXPOSURE COEFFICIENT ........................ K~ = 0 91~. ~. VELOCI~ PRESSURE._ q: = 0.00256. Kz. ~. V3S2. I. psf q = 21.874psf END ZONE WIDTH ...... EZW = 12fl 05, Page 2 of 10 INTERNAL PRESSURE COEFFICIENTS: GCpi iN = -0.18 GCpi OUT = 0. l 8 EXTERNAL PRESSURE COEFFICIENTS - CASE A - TRANSVERSE LOADING: END ZONES GCpfA. iE = 0.78 GCpf.A 2E = -1.07 GCp/A 3E = -0.673 GCp£ A.4E = -0.618 INTERIOR ZONES GCpf.A I = 0.516 GCpfA 2 = -0.69 GCpf.A 3 - -0.469 GCpfA 4 = 0.415 DESIGN PRESSURES - CASE A - TRANSVERSE LOADING: END ZQNES PA. IE l :- q'(GCpf.A IE - GCpi.IN) PA2EI:= q'(GCpfA 2E GCpi IN) PA3EI := q'(GCpt'A 3E - GCpilN) PA 4E I := q'(GCpf A 41 GCpi IN) PA1EI - 21.003psf PA2E I - -19.468 psf PA3E I -10.79psf PA4E 1 = 9.583psf PALE2:= q'(GCpf.A IE - GCpiOUT) PA2E2: q'(GCpfA2E-GCpioU'I) PA 3E2 := q'(GCp£A 3E GCpi OUT) PA.4E.2 := q'(GCpf. A.qE - GCpiOUT) INTERIOR ZONES PAl I := q'(GCpfA I - OCpilN) PA 21: = q'(GCp£A 2 - GCpi IN) PA3.1 := q'(GCpf.A 3 - GCpi IN) PA41 := q'(GCp£A 4 - GCpi IN) PA.1.2 := q'(GCpf. A I - GCpi OUT) PA22 := q'(GCpfA2 - GCpioUT) PA 32 TM q' (GCpfA 3 - GCpi OUT) PA42 := q'(GCp£A.4 - GCpiOUT) PA IE.2 = 13.128psf PA2E 2 = -27.342 psf PA3E2 = -I 8.665 psf PA4E2 = - 17.457 psf PAll = 15.234psf PA21 = -I 1.156psf PA 31 = -6.3l I psf PA 4 1 = -5.149 psf PA.12 = 7.359psf PA22 - - 19.03 psf PA32 - -14.186 psf PA42 = -13.023 psf Page 3 of 10 COLUMN DESIGN CRITERIA: P = 3545.625 lb Columns in End Zone: EZW = 12t~ P Note: Moments at points Ma and Mb and uplift are taken from the attached listing of computer program for building frame analysis. Ma:= 93907. inlb .75 Mb:= 62539. inlb .75 uplift:= 3918-1b .75 END ZONE COLUMNS PN:= P uplift Column Size = "3 - 2x8 Laminated Column" A 32.62sqin Fc 1650psi S -- 39.42cuin Fb = 1730psi Id = 23.17 INTERACTION VALUE:= M. I ,,I x = L5ft INTERACTION VALUE = 0.66 SPLICE CHECK (Mb) As = 32.62 sqin Ss = 26.28 cuin Fcs = 1650psi Fb.s = 1500psi INTERACTION VALUE = 0.759 Page 4 of 10 TRUSS TO COLUMN CONNECTION: ROOF LOAD Truss is saddled between outside members of column and bearing on center member with (2) 1/2" Diameter through Machine Bolts and (12) 20d RS Nails Connector Load = 4038.8 lb P = 4417.5 lb Center Member_Is = "2x8" Areacentermember = 10.875 sqin UPLIFT Bearing_Stress := (P - Connector_Load) Areacentermember Connector_Load = 5619.2 lb BDL = 620 lb NETUPLIFT:-- UPLIFT- BDL NET UPLIFT - 3298 lb Bearing_Stress = 34.823 psi UPLIFT:= uplifi~ UPLIFT = 3918 lb FOOTING: Allowable Soil Bearing_Pressure:= 2000. psf Pfooting = 4417.5 lb Footin~Diameter = 24 in Footing Thickness- 10in · . 2 Footing D~ameter -x Areaact: = 4 Pfooting Areareqd:= Allowable_Soil_Bearing Pressure Areaact = 3.142 Areareqd = 2.209 iff2 Page 5 of 10 EMBEDMENT: Design Criteria: Restrained at ground with Base Anchor Straps in concrete floor To find required embedment depth, solve simultaneous equations below Initial try: ,~:= 4-~ hP:= Ma Given d2- 4.25. hP S3. B S3:= 160~psf B = 0.711 ft S3 = 150.2. 1.33. d. (clubfi ~ Find(d, S3) COLUMN EMBEDMENT DEPTH: d = 4.894fi $3 = 1952.8]3psf Soil Classification #4 BASE ANCHOR STRAP CHECK ~300 Horizontal Shear at Grade: 3/1 6"X3/4"X30" ~ SHEAR:= 1843-1b H.R. Flat Steel SHEAR= 18431b Allowable Shear resisted by two Base Anchor Straps: Consider 22,000 psi steel ~/ x 2.25" '~ Stainless Steel Steel Area = 0,105 in2 ~ Anchor Nails Therefore Allowable Shear = 4620 lb ~ 3 Member Column Allowable Shear resisted by 8 - Stainless Steel Nails: = 8(216)(1.6) = 2764 lb Allowable Withdrawal of Strap in Concrete: = (1.0 in)(0.75 in)(2)(2000 psi) = 3000 lb Page 6 of 10 WIND LOAD UPLIFT: UPLIFT = 39101b P ,,,d,~:= 4. fl R1 = 12in R2:= d. tan(.5236) + R~ R2 = 3.309fl R3 = 2.309~ ~\, 3 0° \ \ \ \ 14 ga. Metal Stilts Fastened w/(4) 0.148"(~ x 2" Stainless Steel Ring Shank Nails Each Corner ~ = 24in d=4fl R3 := R2 - Ri Soil Volume Above Footinq V,V,V~= -qr.d. Ri2+R22+R1.R27 V = 63.928 ft3 Total Soil Weiqht Allowable Soil Weight:= 100. pcf TSW :- V. Allowable_Soil Weight TSW = 6392.758 lb Building_Dead Load BWh 2h D~.~: = [DL. BS. [('~- ) + OV¢]]. (.-j) BDL = 620 lb Total Wei,qht on FootJnq TWF:= TSW + BDL TWF - 7012.758 lb Metal Stilts w/(16) .148" x 2" Stainless Steel Nails COLUMN TO FOOTING CONNECTION: ~apa,~,~= UPLIFT- BDL NET UPLIFT = 32901b No. of Nails Required to Resist Uplift = NAILS = 17 Page 7 of 10 Sliding Door Header (Section D-D): 5-1/4" x 19-1/2" Glu-Lam Beam, Fb = 2400 psi Sact = 332.72 in3 Mmax -- 41,414 ftlb Sreq = 180.06 in3 TRUSS TO HANGER CONNECTION: (14) 1-1/2" R.S. Nails & (1) 1/2" x 2 1/2" M Bolt & 7.5 sqin bearing Allowable Loads = 7,007 lb (Gravity) and 3,854 rb (Uplift) HANGER TO HEADER CONNECTION: (8) 20d R.S. Nails (0.177" dia) & 21.0 sqin Bearing Allowable Loads = 13,250 lb (Gravity) and 3,913 lb (Uplift) HEADER TO HANGER CONNECTION: (3) Base Anchor Nails (0.177" dia) & 21.0 sqin Bearing Allowable Loads = 12,610 lb (Gravity) HANGER/HEADER TO COLUMN CONNECTION: (3) Base Anchor Nails (0.177" dia), 15.75 sqin Bearing, and (14) 20d R.S. Nails Allowable Loads = 28,310 lb (Gravity) and 5544 lb (Uplift) JAMB FOOTING: ~ 30-in wa' 'n '= 2000. psf JF := 6627. lb (worst case) · 2 Footlng__Diameter Areaact = 4.909 ~2 4 JF ~:= Allowable Soil Bearing Pressure Areareqd = 3'313ft2 Page 8 of 10 2x4 PURLINS: Roof load 2 x 4 purlins, No.2 SPF Purlin spacing ............. Roof sheeting load ....... Purlin dead load .......... ,,~= 1509.4. psi PS: = 24- in SL: = 0.9- psf PL:= l.l.psf TOTAL_LOAD:= 20. psf + SL + PL TOTAL_LOAD = 22 psf PS Mmax:= .1071'TOTAL LOAD ~BS2 ~in~ Mrna~ Sreqd: = Fb- 1.15 Mmax = 265.072 lb fi Sreqd = 1.832cuin Uplift 2"x4" Purlin to Truss Connection: Required Purlin Spacing: 627, lb = 25.618 in Net suction. BS Page 9 of 10 SIDEWALL NAILERS: SP = 7.125R 2 x 4 nailers, 2100f MSR SPF ,,,~= 2100. psi NAILER SPACING ....................... NS:= 20, in NAILER TRIBUTARY AREA .......... NTA = 12.5 sqfi NAILER WIND LOAD ................... ~q~= 34.60. psf NS suction (in-~-~ (BS .375. fi)2 = Fb. 1.10. 1.6 Mmax = 365.936 lb- fl: Sreqd = 1.I 88 cuin Suction on Nailers (Fasteners): Maximum nailer spacing: 3nai .1.62 n. 46,b in = 20.421 in suction. BS Actual Nailer Spacing NS = 20 in SEISMIC DESIGN Seismic_Use_Group := 'T' Site_Class:= "D" Spectral response acceleration @ short periods (Ss): Spectral response acceleration @ 1-second periods (S1): Site coefficient (fa): Site coefficient (fy): Sins:= F~Ss Sins = 0.32 Sm1:= Fv.S1 Sml = 0.144 SDS:= (~)Sms SDS=0.213 SDI := (~)Sml SDI= 0-096 Seismic_Design_Category_Ss = "B" Seismic_Design_Category Si = "B" Note: Most severe category governs; therefore Seismic_Design_Category = "B" ,,~: = .20 S1 := .06 Fa = 1.6 Fy = 2.4 Page 10 of 10 SIMPLIFIED ANALYSIS PROCEDURE (SAP) FOR SEISMIC DESIGN OF BUILDINGS Building Weight: N~= 71000lb Response modification factor (R): R:= 7.0 1.2'SDs V:= -W ,wv R V = 2596.571 lb aSSUHPTII3NS aN]3 NFITESI 1, The columns ~re Fixed o~c ~che b~se, a, The Cruss ¢o column connec¢ion is hinged, 3, CircLed numbers ~re poin~c numbers, 4, Uncirc~ed numbers c~re Member numbers, 5, The wind [cod is opp/ied ~co ~che s~puc~u~es by NY~C (aO07) ~ ASCE 7-05 wind lo.din9 ~ecommendo~ions, 6, The Forces ~e computed by Purdue's Pl~e S~puc~upes anoiyzep (U,S,D,A, Fopes~ Senvice Popep FPL ~68. This is ~ computerized s~uc~u~o[ ~no(ysis p~og~m, 60 Ft. frame Case A NLTMBER OF POINTS = 28 NUMBER OF MEMBERS = 47 NI3MBER OF ROLLER SUPPORTS = 0 NUMBER OF PINNED OR FIRL SUPPORTS = NUMBER OF FIXED SUPPORTS = 2 ALLOWABLE MEMBER STRESSES IN PSI, NORMAL LOAD DURATION MEM, USE ALLOWABLE GROUP TYPE BEND COMP TENS WIDTH DEPTH MODULUS OF ELASTICITY 1 CS 1700. 0. 2 CS 1700. 0. 3 CS 1600. 0. 4 CU 1950. 0 5 WI3 1850. 0 6 WU 1600. 0 7 WU 1850. 0 8 CS 1700. 0 9 CS 1700. 0 0. 4.500 7.250 .150E+07 0. 3.000 7.250 .150E+07 0. 1.500 11.250 .150E+07 0. 1~500 11.250 .150E+07 0. 1.500 3.500 .150E+07 0. 1.500 5.500 .150E+07 0. 1.500 3.500 .150E+02 0. 4.500 7.250 .150E+07 0. 3.000 7.250 .150E+07 THE LOAD DURATION FACTOR IS 1.60 POINT COORDINATES POINT X-COORD Y-COORD NO. (IN) (IN) 1 .000 132.000 2 .000 .000 3 85.380 103.540 4 -85.380 103.540 5 50.870 .000 6 -50.870 .000 7 168.870 75.710 8 -168.870 75.710 9 143.630 .000 10 -143.630 .000 11 254.250 47.250 12 -254.250 47.250 13 238.500 .000 14 -238.500 .000 15 320.000 25.330 16 -320.000 25.330 17 320~000 .000 18 -320.000 .000 19 360.000 12.000 20 -360.000 12.000 21 360.000 .000 22 -360.000 .000 23 360.000 -138.000 24 -360,000 -138.000 25 360.000 -156.000 26 -360.000 -156.000 27 360.000 -174.000 28 -360.000 -174.000 MEMBER LAYOUT MEMBER NUMBER NEGATIVE END POINT CONDITION POSITIVE END POINT CONDITION MEMBER GROUP 1 28 RIGID 26 RIGID 1 2 26 RIGID 24 RIGID 2 3 24 RIGID 22 RIGID 1 4 22 RIGID 20 RIGID 1 5 20 pIhrNED 16 RIGID 3 6 16 RIGID 12 RIGID 3 7 12 RIGID 8 RIGID 3 8 8 RIGID 4 RIGID 3 9 4 RIGID 1 RIGID 3 10 1 RIGID 3 RIGID 3 11 3 RIGID 7 RIGID 3 12 7 RIGID 11 RIGID 3 13 11 RIGID 15 RIGID 3 14 15 RIGID 19 PINNED 3 15 19 RIGID 21 RIGID 8 16 21 RIGID 23 RIGID 8 17 23 RIGID 25 RIGID 9 18 25 RIGID 27 RIGID 8 19 22 PINNED 18 RIGID 4 20 18 RIGID 14 RIGID 4 21 14 RIGID 10 RIGID 4 22 10 RIGID 6 RIGID 4 23 6 RIGID 2 RIGID 4 24 2 RIGID 5 RIGID 4 25 5 RIGID 9 RIGID 4 26 9 RIGID 13 RIGID 4 27 13 RIGID 17 RIGID 4 28 17 RIGID 21 PINNED 4 29 12 PINNED 14 PINNED 5 30 8 PINNED 10 PINNED 5 31 4 PINNED 6 PINNED 6 32 1 PINNED 2 PINNED 7 33 5 PINNED 3 PINNED 6 34 9 PINNED 7 PINNED 5 35 13 PINNED 11 PINNED 5 36 14 PINNED 8 PINNED 5 37 10 PINNED 4 PINNED 5 38 6 PINNED 1 PINNED 6 39 1 PINNED 5 PINNED 6 40 3 PINNED 9 PINNED 5 41 7 PINNED 13 PINNED 5 42 22 PINNED 16 PINNED 3 43 20 PINNED 18 PINNED 3 44 16 PINNED 18 PINNED 3 45 17 PINNED 19 PINNED 3 46 15 PINNED 21 PINNED 3 47 15 PINNED 17 PINNED 3 REACTION CONDITIONS POINT REACTION HORIZ VERT NUMBER TYPE DISPL DISPL 27 FIX .00 .00 28 FIX .00 .00 MEMBER PROPERTIES MEMBER NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 LENGTH (IN) 18.000 18.000 138.000 12.000 42.163 69.308 89.998 88.006 89.998 89.998 88.006 89.998 69.308 42.163 12.000 138.000 18.000 18.000 40.000 81.500 94.870 92.760 WIDTH (IN) 4.500 3.000 4.500 4.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1,500 1.500 4.500 4.500 3.000 4.500 1.500 1.500 1.500 1.500 DEPTH (IN) 7.250 7.250 7.250 7.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 7.250 7.250 7.250 7.250 11.250 11.250 11.250 11.250 MODULUS OF EIJtSTICITY .150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 .150E+07 ~150E+07 .150E+07 .150E+07 .150E+07 ,150E+07 .150E+07 ~150E+07 .150E+07 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 4O 41 42 43 44 45 46 47 50.870 50.870 92.760 94.870 81.500 40.000 49.806 79.806 109.140 132.000 109.140 79.806 49.806 102.861 118.801 141.463 141.463 118.801 102.861 47.346 41.761 25.330 41.761 47.346 25.330 1.500 1.500 1.500 1.500 1.500 1.500 1,500 1.500 1.500 1.500 1.500 1,500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.SO0 11.250 11.250 11.250 11.250 11.250 11.250 3.500 3.500 5.500 3.500 5.500 3.500 3.500 3.500 3.500 5.500 5.500 3.500 3.500 11.250 11.250 11.250 11.250 11.250 11.250 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+02 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 THE STRUCTURE HAS UNIFORM LOADS AS FOLLOWS MEMBER HORIZ VERT NUMBER COMP COMP (PLI) (PLI) 1 13.130 .000 2 13.130 .000 3 13.130 .000 4 13.130 .000 5 -12.200 12.200 6 -12.200 12.200 7 -12.200 12.200 8 -12.200 12.200 9 -12.200 12.200 10 6.740 6.740 11 6.740 6.740 12 6.740 6.740 13 6.740 6.740 14 6.740 6.740 15 5.990 .000 16 5.990 .000 17 5.990 .000 18 5.990 .000 *** REACTIONS *** REACTION HOR. COMP. VERT. COMP. MOMENT POINT (LBS) (LBS) (IN-LBS 27 -1040.270 -2900.710 63347.552 28 -1860.850 -3917.690 93906.522 *** STRENGTH ANALYSIS *** MEMBER NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 MEMBER END ACTIONS LOCATION AXIAL SHEAR MOMENT (LBS) (LBS) (IN-LBS) NEG END -3917.690 1860.850 93906.522 POS END 3917.690 -1624.510 -62538.279 NEG END -3917.690 1624.510 62538.279 POS END 3917.690 -1388.170 -35424.156 NEG END -3917.690 1388.170 35424.156 POS END 3917.690 423.770 31119.468 NEG END -1861.692 -2514.509 -31119.468 POS END 1861.692 2672.069 .000 NEG END -2206.952 311.288 .000 POS END 2206.952 -825.672 23968.625 NEG END -6904.432 -910.778 -23968.625 POS END 6904.432 65.225 -9853.622 NEG END -6904.429 -361.593 9853.622 POS END 6904.429 -736.388 7011.883 NEG END -7184.634 -554.373 -701t.883 POS END 7184.634 -519.302 5468.672 NEG END -6165.923 -501.120 -5468.672 POS END 6165.923 -596.861 9776.973 NEG END -5897.034 -392.449 -9776.973 POS END 5897.034 -214.140 1753.207 NEG END -6513.480 -279.420 -1753.207 POS END 6513.480 -313.741 3263.444 NEG END -6514.166 -400.270 -3263.444 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 3O 31 POS END 6514.166 -206.319 -5464.181 NEG END -6514.164 -31.653 5464.181 POS END 6514.164 -435.480 8529.958 NEG END -4313.352 -344.399 -8529.958 POS END 4313.352 60.223 .000 NEG END -1854.554 -2284.505 .000 POS END 1854.554 2212.625 -26982.778 NEG END -2900.710 -1.990 26982.778 POS END 2900.710 -824.630 29779.358 NEG END -2900.710 824.630 -29779.358 POS END 2900.710 -932.450 45593.075 NEG END -2900.710 932.450 -45593.075 POS END 2900.710 -1040.270 63347.552 NEG END 1816.436 418.221 .000 POS END -1816.436 -418.221 16728.837 NEG END 6680.671 -381.990 -16728.837 POS END -6680.671 381.990 -14403.383 NEG END 6803.875 134.626 14403.383 POS END -6803.875 -134.626 -1631.432 NEG END 5770.370 13.370 1631.432 POS END -5770.370 -13.370 -391.220 NEG END 4441.524 5.043 391.220 POS END -4441.524 -5.043 -134.696 NEG END 4441.524 5.033 134.696 POS END -4441.524 -5.033 121.341 NEG END 5168.689 -19.575 -121.341 POS END -5168.689 19.575 -1694.474 NEG END 5802.672 -67.183 1694.474 POS END -5802.672 67.183 -8068.117 NEG END 5878.341 157.742 8068.117 POS END -5878.341 -157.742 4787.885 NEG END 4051.699 -119.697 -4787.885 POS END -4051.699 119.697 .000 NEG END -296.052 .000 .000 POS END 296.052 .000 .000 NEG END -1135.669 .000 .000 POS END 1135.669 .000 .000 NEG END -1944.301 .000 .000 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 POS END 1944.301 NEG END .010 POS END -.010 NEG END -1052.617 POS END 1052.617 NEG END -714.376 POS END 714.376 NEG END -237.676 POS END 237.676 NEG END -320,302 POS END 320.302 NEG END 1375.296 POS END -1375.296 NEG END 1985.701 POS END -1985.701 NEG END 1096.572 POS END -1096.572 NEG END 832,218 POS END -832.218 NEG END .752 POS END -.752 NEG END -4624.692 POS END 4624.692 NEG END 5078.411 POS END -5078.411 NEG END -659.059 POS END 659.059 NEG END 1907.070 POS END -1907.070 NEG END -2179.159 POS END 2179.159 NEG END -270.553 POS END 270.553 · 000 .000 .000 .000 ,000 .000 .000 .000 .000 .000 .000 · 000 .000 .000 000 000 00O O00 000 .000 .000 .000 .000 · 000 .000 .000 .000 ,000 .000 ,000 .000 .000 .000 .000 000 000 000 000 000 .000 .000 .000 .000 · 000 .000 .000 .000 · 000 .000 · 000 .000 .000 000 000 000 000 .000 .000 ,000 · 000 .000 .000 .000 .000 .000 .000 POINT POINT DISPLACEMENTS DISPL., HORIZ. OR DISPLACEMENT, IN DIR. OF ROLLER VERTICAL DISPLACEMENT, ROTATIONAL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 (IN) .164Ee01 .163E+01 .166E+01 .161E+01 .162E+01 .164E+01 .167E+01 ,159E+01 .160E+01 .166E+01 ,166E+01 ,160E+01 158E+01 168E+01 161E+01 168E+01 156E+01 170E+01 158E+01 .170E+01 .155E+01 .171E+01 .188E+00 .270E+00 .505E-01 .756E-01 ,000E+00 .000E+00 (IN) .474E+00 .490E+00 .473E+00 .508E+00 .478E+00 .500E+00 .434E+00 .492E+00 .451E+00 .504E+00 .319E+00 .371E+00 .345E+00 .397E+00 .107E+00 ,758E-01 .107E+00 .751E-01 .l13E-01 .151E-01 .108E-01 .147E-01 .267E-02 .360E-02 .107E-02 .144E-02 .000E+00 .000E+00 P~AD IANS ) -.431E-03 -.218E-03 -.207E-04 -.224E-03 -.219E-03 -.168E-03 -.628E-03 .314E-03 -.493E-03 .183E-03 -.253E-02 .357E-02 -.223E-02 .303E-02 -.283E-02 .301E-02 -.273E-02 .268E-02 -.331E-02 ,245E-03 -.407E-02 -.635E-03 -.929E-02 -.127E-01 -.456E-02 -,654E-02 .000E+00 .000E+00 60 Pt. frame Case B NUMBER OF POINTS = 28 NUMBER OF MEMBERS = 47 NI3MBER OF ROLLER SUPPORTS = 0 NUMBER OF PINNED OR FIRL SUPPORTS = NUMBER OF FIXED SUPPORTS = 2 ALLOWABLE MEMBER STRESSES IN PSI, NORMAL LOAD DUP~ATION MEM. USE ALLOWABLE GROUP TYPE BEND COMP TENS WIDTH DEPTH MODULUS OF ELASTICITY 1 CS 1700. 0. 0. 4.500 7.250 2 CS 1700. 0. 0. 3,000 7.250 3 CS 1600. 0. 0. 1.500 11.250 4 CU 1950. 0. 0. 1.500 11.250 5 WU 1850. 0. 0. 1.500 3,500 6 WU 1600. 0. 0. 1.500 5.500 7 WU 1850. O, 0. 1.500 3.500 8 CS 1700. 0. 0. 4.500 7.250 9 CS 1700. 0. 0. 3.000 7.250 .150E+07 .150E+07 .150E~07 .150E+07 .150E+07 .150E+07 .150E+02 .150E+07 .150E+07 THE LOAD DUR3tTION FACTOR IS 1.60 POINT COORDINATES POINT X-COORD Y-COORD NO. (IN) (IN) 1 .000 132.000 2 ,000 .000 3 85.380 103.540 4 -85,380 103.540 5 50,870 .000 6 -50.870 .000 7 168.870 75.710 8 -168.870 75.710 9 143.630 .000 10 -143.630 .000 11 254.250 47.250 12 -254.250 47.2S0 13 238.500 .000 14 -238,500 .000 15 320,000 25,330 16 -320.000 25.330 17 320.000 .000 18 -320.000 .000 19 360.000 12.000 20 -360.000 12.000 21 360,000 .000 22 -360.000 .000 23 360,000 -138.000 24 -360.000 -138.000 25 360,000 -156.000 26 -360.000 -156.000 27 360.000 -174.000 28 -360.000 -174.000 MEMBER LAYOUT MEMBER NI3MBER NEGATIVE END POINT CONDITION POSITIVE END POINT CONDITION MEMBER GROUP 1 28 RIGID 26 RIGID 1 2 26 RIGID 24 RIGID 2 3 24 RIGID 22 RIGID 1 4 22 RIGID 20 RIGID 1 5 20 PINNED 16 RIGID 3 6 16 RIGID 12 RIGID 3 7 12 RIGID 8 RIGID 3 8 8 RIGID 4 RIGID 3 9 4 RIGID 1 RIGID 3 10 1 RIGID 3 RIGID 3 11 3 RIGID 7 RIGID 3 12 7 RIGID 11 RIGID 3 13 11 RIGID 15 RIGID 3 14 15 RIGID 19 PINNED 3 15 19 RIGID 21 RIGID 8 16 21 RIGID 23 RIGID 8 17 23 RIGID 25 RIGID 9 18 25 RIGID 27 RIGID 8 19 22 PINNED 18 RIGID 4 20 18 RIGID 14 RIGID 4 21 14 RIGID 10 RIGID 4 22 10 RIGID 6 RIGID 4 23 6 RIGID 2 RIGID 4 24 2 RIGID 5 RIGID 4 25 5 RIGID 9 RIGID 4 26 9 RIGID 13 RIGID 4 27 13 RIGID 17 RIGID 4 28 17 RIGID 21 PINNED 4 29 12 PINNED 14 PINNED 5 30 8 PINNED 10 PINNED 5 31 4 PINNED 6 PINNED 6 32 1 PINNED 2 PINNED 7 33 5 PINNED 3 PINNED 6 34 9 PINNED 7 PINNED 5 35 13 PINNED 11 PINNED 5 36 14 PINNED 8 PINNED 5 37 10 PINNED 4 PINNED 5 38 6 PINNED 1 PINNED 6 39 1 PINNED 5 PINNED 6 40 3 PINNED 9 PINNED 5 41 7 PINNED 13 PINNED 5 42 22 PINNED 16 PINNED 3 43 20 PINNED 18 PINNED 3 44 16 PINNED 18 PINNED 3 45 17 PINNED 19 PINNED 3 46 15 PINNED 21 PINNED 3 47 15 PINNED 17 PINNED 3 REACTION CONDITIONS POINT REACTION HORIZ NUMBER TYPE DISPL 27 FIX .00 28 FIX .00 VERT DISPL .00 .00 MEMBER PROPERTIES MEMBER NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 LENGTH (IN) 18.000 18.000 138.000 12.000 42,163 69.308 89.998 88.006 89.998 89.998 88.006 89.998 69.308 42.163 12.000 138.000 18.000 18.000 40.000 81.500 94.870 92.760 WIDTH {IN) 4.500 3.000 4.500 4.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 4.500 4.500 3.000 4.500 1.500 1.500 1.500 1.500 DEPTH (IN) 7.250 7.250 7.250 7.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 11.250 7.250 7.250 7.250 7.250 11.250 11.250 11.250 11.250 MODULUS OF EL~ASTICITY .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E~07 .150E+07 .150E+07 23 50.870 1.500 11,250 24 50.870 1.500 11.250 25 92.760 1~500 11.250 26 94.870 1.500 11,250 27 81.500 1.500 11.250 28 40,000 1.500 11.250 29 49.806 1.500 3.500 30 79,806 1.500 3.500 31 109.140 1.500 5.500 32 132.000 1,500 3.500 33 109.140 1.500 5.500 34 79.806 1.500 3.500 35 49.806 1.500 3.500 36 102.861 1,500 3.500 37 118.801 1.500 3,500 38 141.463 1,500 5.500 39 141,463 1.500 5,500 40 118,801 1,500 3.500 41 102~861 1.500 3.500 42 47.346 1.500 11.250 43 41.761 1.500 11,250 44 25.330 1.500 11.250 45 41.761 1,500 11.250 46 47.346 1,500 11.250 47 25.330 1.500 11.250 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+02 .150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 150E+07 .150E+07 .150E+07 .150E+07 .150E+07 .150E+07 THE STRUCTURE HAS UNIFORM LOADS AS FOLLOWS MEMBER HORIZ VERT NUMBER COMP COMP (PLI) {PLI} 1 8.210 .000 2 8.210 .000 3 8.210 .000 4 8.210 .000 5 -17.100 17.100 6 -17.100 17.100 7 -17.100 17.100 8 -17.100 17.100 9 -17.100 17.100 10 11.700 11.700 11 11.700 11.700 12 11.700 11.700 13 11.700 11.700 14 11.700 11.700 15 10.900 .000 16 10.900 .000 17 10.900 .000 18 10.900 .000 ******************************* RESULTS ******************************* *** REACTIONS *** REACTION HOR. COMP. VERT. COMP. MOMENT POINT (LBS) (LBS) (IN-LBS) 27 -1465.661 -4679.469 75150.554 28 -1440.799 -5688.531 82664.106 *** STRENGTH ANALYSIS *** MEMBER NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 LOCATION NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END POS END NEG END MEMBER END ACTIONS AXIAL SHEAR MOMENT (LBS) (LBS) (IN-LBS) -5688.531 1440.799 82664.106 5688.531 -1293.019 -58059.738 -5688.531 1293.019 58059.738 5688.531 -1145.239 -36115.410 -5688.531 1145.239 36115.410 5688.531 -12.259 43752.000 -2630.803 -3596.740 -43752.000 2630.803 3695.260 .000 -3198.237 467.495 .000 3198.237 -1188.476 34910.067 -10143.228 -1306.505 -34910.067 10143.228 121.344 -14570.364 -10143.223 -497.086 14570.364 10143.223 -1041.887 9945.247 -10614.496 -781.664 -9945.247 10614.496 -723.242 7374.474 -9205.302 -686.126 -7374.474 9205.302 -852.847 14876.746 -8940.966 -650.622 -14876.746 8940.966 -402.360 3705.151 -9956.159 -486.283 -3705.151 9956.159 -543.390 6218.052 -9776.814 -708.026 6218.052 POS END 13 NEG END POS END 14 NEG END POS END 15 NEG END POS END 16 NEG END POS END 17 NEG END POS END 18 NEG END POS END 19 NEG END POS END 20 NEG END POS END 21 NEG END POS END 22 NEG END POS END 23 NEG END POS END 24 NEG END POS END 25 NEG END POS END 26 NEG END POS END 27 NEG END POS END 28 NEG END POS END 29 NEG END POS END 30 NEG END POS END 31 NEG END 9776.814 -9776.815 9776.815 -5338.902 5338.902 -2634.585 2634.585 -4679.469 4679.469 -4679.469 4679.469 -4679.469 4679.469 2190.422 -2190.422 9067.673 -9067.673 9313.662 -9313.662 7886.621 -7886,621 6048.629 -6048,629 6048.629 -6048.629 7294.260 -7294.260 8330,642 -8330.642 8294.498 -8294,498 4466.830 -4466.830 -375.279 375.279 -1562.710 1562,710 -2687.380 -344.955 19.912 -830.812 -705.850 212.547 -1304.583 1173.783 -430.939 -1073.261 1073.261 -1269.461 1269.461 -1465.661 614.756 -614.756 -557.081 557,081 195,445 -195.445 19.863 -19.863 5.022 -5.022 5.007 -5.007 -26.183 26.183 -127.669 127.669 331,180 -331,180 -313.330 313.330 ,000 .000 .000 .000 .000 -10119.838 10119.838 19361.011 -19361.011 .000 .000 -14870.199 14870.199 29449.971 -29449.971 50534.462 -50534,462 75150.554 ,000 24590.240 -24590.240 -20811.830 20811.830 -2269.963 2269.963 -427.492 427.492 -172.023 172.023 82,704 -82.704 -2346,028 2346.028 -14457.995 14457.995 12533.196 -12533.196 .000 .000 .000 .000 .000 .000 POS END 32 NEG END POS END 33 NEG END POS END 34 NEG END POS END 35 NEG END POS END 36 NEG END POS END 37 NEG END POS END 38 NEG END POS END 39 NEG END POS END 40 NEG END POS END 41 NEG END POS END 42 NEG END POS END 43 NEG END POS END 44 NEG END POS END 45 NEG END POS END 46 NEG END POS END 47 NEG END POS END 2687.380 .015 -.015 -1809.328 1809.328 -1152.140 1152.140 -324.597 324.597 -538.698 538.698 1902.462 -1902.462 2748.172 -2748.172 1872.975 -1872.975 1370.542 -1370.542 -205.028 205.028 -6864.431 6864.431 7180.061 -7180.061 -891.339 891.339 3996.203 -3996.203 -4407.861 4407.861 -503.790 503.790 000 000 000 · 000 .000 .000 · 000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 000 000 000 .000 .000 .000 .000 .000 000 000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 000 000 000 .000 .000 · 000 .000 .000 .000 .000 000 000 000 000 .000 .000 .000 · 000 DISPL., POINT IN DIR. POINT DISPLACEMENTS HORIZ. OR DISPLACEMENT, OF ROLLER VERTICAL DISPLACEMENT, ROTATIONAL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 (IN) .165E+01 .164E+01 .169E+01 .160E+01 .163E+01 .165E+01 .171E+01 .157E+01 .160E+01 .168E+01 .169E+01 .159E+01 .157E+01 .171E+01 .160E+01 .171E+01 .154E+01 .174E+01 .157E+01 ,173E+01 .153E+01 .175E+01 ,217E+00 ,243E+00 .604E-01 .662E-01 .000E+00 .000E+00 (IN) .696E+00 .720E+00 ,704E+00 .739E+00 .708E+00 .730E+00 .654E+00 ,711E+00 .678E+00 .729E+00 .483E+00 .535E+00 .521E+00 .572E+00 .139E+00 .107E+00 .138E+00 .106E+00 .181E-01 .219E-01 .175E-01 .213E-01 ,430E-02 .523E-02 .172E-02 .209E-02 .000E+00 .000E+00 (R~DIANS) -.426E-03 -.216E-03 ,441E-04 -.285E-03 -.224E-03 -.158E-03 -.810E-03 .498E-03 -.617E-03 .310E-03 -.413E-02 .517E-02 -.360E-02 ,441E-02 -.415E-02 .431E-02 -.390E-02 .383E-02 -.339E-02 .283E-03 -.381E-02 -.947E-03 -.103E-01 .l18E~01 -.525E-02 -.589E-02 .000E+00 .000E+00 O~ APPROVEI~ BY PLANNING BOARD 'tOWN OF SOUTHOLD UNDERWRITERS CERTIFICATE: AP/PR0/VED AS NOTED DAT~ B.p. # :.~,'~/:~.~:- 765 802 8AM TO 4PM FOR TRE 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMrNG & PLUMBING 3. INSULATION 4. FINAL - CON3TPUCTION MUST BE COMPLETE ;OR C O. ALL CONSTRDC¢IL,N SRALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK SLATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS, COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES ,~ J,'4S OF AS REQUIRED ANDCO. ,--r.~ ~'/ SOUTHJ., ,r, ,.~ SOUT JL' ,', ~,'A';NGGOARD N.YS DEC CEflTIFICATI( NAtLIN~ &~ REQUIRE ........ \LL cONST ME :"T THE REC oDES OF C CCUPAI ~ SE IS U! I ....... ---I VITHOU; --- ' ,F OCCL ~ETAIN STOfl ...... :URSUANT T - ',OM PLY W :LOO~ DAM - ;OUTHOLD ..... PI UMBER CE . ' ON '.FAD CON: ...... CEF 'IFICA TE o, S, ~LDER USE, SL ?PLYSYST E,~ ;EED 2/10 PANCY I/l WATER RUNOFF ~ CHAPTER 238 CODE. PREVENTION ~ON :OCCUPANCY ]INWATER Z-kd)A/ PLUMBING ALL PLUMBING WASTE & WATER LINES NEED TESTING BEFORE COV,ERING z z R ;j~pKOVED BY BOARD ~ite dcvelopmcra plan shall be v~id for a period of ~ (3) ye~ ~om me u=~ ~ code s~tlon E ,/ ,.GIT~ DATA TOTAL. ~ · 24,2 GONCEPTUAL 5ITE PLAN ] N Young & Young 400 Os~ra~der Avenue, l~iverhea& liew York 11901 631-?£?-2303 ~1'I~ DATA TOTAL AF~.A - 24.~ NAP FOR EDI/',IAf:RD H. HARBE5 III ~ubdivi~lon: Hell~ ~rms A~ J~meepor~ Tonn o~ Rlverhe=d $Tonn o~ ~outhol~ &OO O~ OI 2.14 CONCEPTUAL 61'1~ PLAN MORTON BUILDINGS GENERAL SPECIFICATIONS LAMINATED COLUMNS - NO. I OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .B POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE IlL OXIDE IN CONFORMANCE WITH USEPA GUIDELINES AND AWPA STANDARD C28. THE TREATED PORTION OF THE COLUMN EMBEDDED IN GROUND SHALL BE LAMINATED WiTH STAINLESS STEEL NAILS, FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG A MINIMUM DEPTH OF 4'~8'' BELOW GRADE (SEE plANS FOR DIAMETER AND DEPTH). COLUMNS WITH GALVANIZED SUPPORT STILTS ARE PLACED IN THE HOLE. CONCRETE (MINIMUM COMPRESSIVE STRENGTH 2500 PSi) IS POURED IN PLACE TO THE SPECIFIED THICKNESS (SEE pLANS FOR REQUIRED THICKNESS ABOVE AND BELOW THE COLUMN). THE COLUMN IS THEN BACKFILLED WITH SOIL AND COMPACTED AT B" INTERVALS OR BACKFILLED WITH CONCRETE (SEE PLANSJ. TREATED LUMB[~ - PRESSURE pRESERVATIVE TREATED LUMBER OTHER THAN LAMINATED COLUMNS ARE NO. 1 OR BEITER SOUTHERN YELLOW PiNE AND CENTER MATCHED OR NOTCHED AND GROOVED, PRESSURE TREATED TO A NET RETENTION OF ,4 POUNDS PER CUBIC FOOT WITH A CODE AND INDUSTRY APPROVED PRESERVATIVE TREATMENT IN ACCORDANCE WITH AWPA USE CATEGORY UC4A. FRAMING LUMBER - SIDING NAILERS ARE 2x4 S4~ QR 2x6 SPF NO. 2 OR BE~FER SPACED APPROXIMATELY 36" O.C. WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2x4 S4S NO. 2 OR BEITER ON EDGE SPACED APPROXIMATELY 24" O,C, ALL OTHER FRAMING LUMBER IS NO, 2 OR BRIER. ROOF TRUSSES - FACTORY ASSEMBLED WITH lB OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN-PLANT QUALITY CONTROL iNSPECTION IS CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU, TRUSSES ARE DESIGNED IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. SIDING PANELS (KYNAR B00 / HYLAR 50OD) - 0.019" MIN,, G90 GALVANIZED OR AZ55 GALVALUME, WITH AN ADDITIONAL BAKED-ON KYNAR 500 / HYLAR 5000 FINISH WITH A NOMINAL 1 MIL. PAINT THICKNESS ON EXTERIOR. ROOFING PANELS JFLUOROFLEX 2000 TM) . 0,019" MIN. AZ55 GALVALUME WiTH AN ADDITIONAL BAKED-ON THICKNESS POLYURETHANE PRIMER AND KYNAR 500 / HYLAR 5000 TOPCOAT WITH A TOTAL MINIMUM PAINT THICKNESS OF 2 MILS ON EXTERIOR. TRIM - DIE-FORMED TRIM OF 0,019" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, RIDGES, CORNERS, BASE WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. GU1TERS - 5" K-STYLE, .030 HIGH TENSILE ALUMINUM GUT[ER, KYNAR 500 / HYLAR 5000 FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDING. ADDITIONAL NOTES I,) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED AS PART OF THESE DRAWINGS. 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY ASTM E84 FOR ORDINARY CONDITIONS AND 28 OR LESS FOR EXITS* PASSAGEWAYS, AND CORRIDORS, B,) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD BHALL MEET THE SAME TESTING PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. 5.)KYNAR 500 IS A REGISTERED TRADEMARK OF ATOFINA CHEMICAL, INC., HYLAR SgOO IS A TRADEMARK OF SOLVAY SOLL:XJS. ~x4FK 11/05 SHEET INDEX SHEET# DESCRIPTION G1 OF 81 SPECIFICATIONS & SHEET INDEX Sl OF S7 COLUMN PLAN __ S2 OF S7 TRUSS PLAN & DETAILS S3 OF 57 TRUSS DRAWING & PURLIN LAYOUT __ S4 OF S7 ELEVATIONS S5 OF S7 FASTENING SCHEDULE & DETAILS S6 OF S7 SECTIONS & D~AILS S7 OF S7 DETAILS EARTHQUAKE DESIGN DATA TABLE 0.2 SEC SPECTRAL RESPONSE 0.200 ACCELERATION (Ss) .0 SEC SPECTRAL RESPONSE 0.OBg ACCELERATION (Si) TYPICAL LUMBER SPECIFICATIONS - 2001 NDS SrZE DESCRIPTION BENDING VALUE Fb 2)(4 NO. 1 &2$PF 1313 PSI 2x4 210Of MSR SPF 2100 PSI 2x6 NO. ] &2SPF 113B PSI 2x6 NO, 1 SYP 1650 PSI 2~8 NO, 1 SYP 1 BOO PSi 2xl 0 NO, 1 SYP 1300 PSi 2x12 NO. 1 SYP 1250 PSI NOTE: HIGHER GRADE MATEI:IAL REQUIRED AS NOTED ON pLANS. BUILDING DESIGN CRITERIA BUILDING CODE USE GROUP CONSTRUCTION TYPE t( / FLOOR AREA 11,700 SQFT MEAN ROOF HEIGHT BUILDING CATEGORY MINIMUM LIVE ROOF LOAD DESIGN SEE BELOW ·'OOF SNOW LOAD* 13 PSF ~AX. D~SlGN ELEVATION 1000 r~OUND SNOW LOAD 20 PSF SPEED (Vas) IMPORTANCE FACTOR EXPL ,~RE CATEGORY INTEF" AL PRESSURE COEFFICIENT BUIIJ ~G DESIGN CONDITION PEA: ~EIGHT BUlLL 'G VOLUME WINI' C)AD DESIGN MAIN ~NDFORCE RESISTING SYSTEM 120 MPH 0.77 C ENCLOSED 25.5 FT 239,850CU FT ASCE 7 METHOD 2 ZONE IE 21.02 PSF ZONE 2E -27.37 PSF ZONE 3E -18.68 PSF -17.47 PSF ZONE 4 ZONE 4E ZONE 5E 21.02 P;SF ZONE 6E -17.47 PSI: ZONE 1 15.25 PISF ZONE 2 -19.05 PSF ZONE 3 -14,20 PSF ZONE 5 ZONE6 ZONE 1 15.25 PS~ ;OMPON~ Ir & CLADDING WIND LOADS -13.04 PS~ 14.89, -23.6: PSF ZONE 2 14.89,~41,16 P ZONE 3 14.89,-B0,B7 P~ ZONE 4 25.84,-2B.03 ZONE5 25.84,-34.60 P MINIMUM LIVE ROOF LOAD DESIGNS FOR CONSTRUCTION, MAINT[NANf REPAIR, AND OTHER TEMPORARY LOADS PER SECTION 1607.107.1~,~1. / 1. ROOF PURLINS AND OTHER SECONDARY STRUCTURAL(,/ MEMBERS = 20 PSF 2, ROOF TRUSSES, HEADERS, COLUMNS AND OTHER PRIMARY STRUCTURAL MEMBERS = 15 PSi: B. FOOTINGS: J3 PSF (DESIGNED FOR ROOF SNOW LOAD AND OTHER NON'TEMPORARY LOADS WITH APPROVAL FROM BUILDING OFFICIAL) ROOF SNOW LOAD CALCULATIONS Ps = O,TxCexlxPgxCfxCs Ce = SNOW EXPOSURE FACTOR = 1.0 I = IMPORTANCE FACTOR = 0.B Pg = GROUND SNOW LOAD = 20 PSF Ct - THERMAL FACTOR = 1,2 Cs = ROOF SLOPE FACTOR = 0,94 Ps : 0.Txl.0xO.Gx20xl,2xO,94=12,6PSF WITHr':' , lr CAT APPROVED AS NOTED ALL CONST t CTION SHALL MEETTHE REOL ,i: ,,,SOFTHE CODES OF NEW YOBK STATE, "JJ I ERWR R$ CERTI REQUIflED RETA1N ORNI w TER RUNOFf: PURSUANT TO CHAPTER 236 OF THE TOWN COOE, I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR THIS BUILDING WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY DATE: WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON UNLESS ACTING UNDER THE DIRECTION OF THE LICENSED ARCHITECT OR LICENSED ENGINEER TO ALTER ANY ARCHITECTURAL OR ENGINEERING ITEM. CUTCHOGUE, N~Y . n 0 II I II I 7 ~DRA WN BY: KLEIN DA TE: 03/27/08 CHECKED BY,' BOG gA TE: 05/12/08 ~EVISED DATE: -- ~EVISED DATE: -- eEVISED DARE; -- REVISED DATE,' -- · SCALE: AS NOTED ~'~ SHEET NO, · Glo G1 $9'-9' 52'-4 1/2" 44'-10 1/2". 41'-7 1/9" 18'-1 14'-10 1/2" ' 7'-4 1/2" _,- ? 'T ~' 'T 7'-6" '- 7'-6" 7'-6" 7'-6" 7'-6" 24"B 16"B \ / b 7'-6" 7'-6" 7'-6" 7'-6" 24"B 24"B 24"B 24"B ¥ ¥ Y 24"B COLUMN PLAN LEGEND a . 3-2x6 LAMINATED COLUMN LOCATION [] - 8-2x6 LAMINATED COLUMN W/2x6xT' STIFFENER fl - 3-2x8 LAMINATED COLUMN LOCATION m - HEADEREDTRUSS LOCATION [] - (8) 8068 9*LITE TEMPERED GLASS IN LEAF WITH EMBOSSED OROSSBUCK EJBERSTEEL WALKDOOR(S) WJCLOSRR, DRADBOLT, & LOOKSET Q 22'-6" x 13'-7 1J2" DOUBLE SLIDING ALUMASTEEL SIDE DOOR(S) W/WEATHERSEAL ~) (2) 24'-0" X 14' DOUBLE SLIDINg ALUMASTEEL END DOOR(S) W/WEATHERSEAL ALL STEEL FASTENED W/S.S. SCREWS (13) 3065 SKYLITEJS) (VERIFY LOCATION) (3) 3'-6"x3'-6" CUPOLA WITH M 30 WEATHERVANENON-FUNCTIONAL ~ 81M BASE ANCHORS (6"B- 6" DIAMETER FOOTING WITH B"THICK MINIMUM READY-MIX CONCRETE BELOW BOTTOM OF LOWER COLUMN W TH ADD TIONAL READY-MIX BACKFILLED TO 4" BELOW GRADE, PLACE CONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION. 24'B- 24" DIAMETER FOOTING WITH J0Ir THICK MINIMUM READY-MIX CONCRETE BELOW BOTTOM OF LOWER COLUMN WITH ADDITIONAL READY-MIX BACKFILLED TO 4" BELOW GRADE, PLACE CONCRETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION. 30"B- 13" THICK MINIMUM READI-MIX CONCRETE BELOW BOTI'OM OF LOWER COLUMN WITH ADDITIONAL READEMIX BACKFILLED TO 4" BELOW GRADE, PLAOE CONORETE BELOW AND ABOVE BOTTOM OF LOWER COLUMN IN ONE OPERATION. ROUGH OPENING SCHEDULE UNIT SYMBOL WIDTH HEIGHT FROM LEGEND [] 38 1/4" 8]" 3'-11 1/4" 30"B 22'-1 1/2" 3'-I1 1 24"B 24"B 24"B 24"B 24~'B 24"B 24"B ¥ Y ¥ Y Y 7'-6'' 7'-6" 24"B Y 7'-6" '1' 7'-6" 24"B 24"B 7'-6" 7'-6" 24"B 24"B ¥ ¥ 24'B 24"B 24"B 24"B ¥ 7~.6,, 7L6. COLUMN PLAN 24'B 16' 24"B SCALE: 1'-0" VENTED SIDEWALL OVERHANGS 16"B 16"~ 24"B 7'-4 1/2" Z ,59'-9" 52~-4 1/2" 44'-10 1/2" · 41'-7 18'-1 1/2" 14'-10 1/2" 7'-4 1/2" CALLED dDWALL OVERHANGS CUTCHOGUE, NY n 0 II I II I m ~J II Ii DA TE: 03/27/08 CHECKED B~' SOG DA TR: 05/12/08 REVISED DA PE., ..- REVISED DATE: -_ o5, ~- SCALE; AS NOTED SHEET NO. · SloES7 7'-4 1/2" ~"- 7'-6" L~ 7'-6" ¢~ ?'-6" 7'-6" 7~-6'' ~ 7'-6" ~o 7'-6" -o 7'-6" 7'-6" 7'-6" - 7'-6" 7'-6" TRUSS/BRACING PLAN LEGEND (~) ~ 60' 2090 S,C. TRUSSES @ 7 - 60' END RAFTER ASSEMBLY - 2x4TRUSS TIES @ 3-9 O, . - 2X6 DIAGONAL END BRACES @ 7~-6" O,C. (TO EXlEND TO FIRST TRUSS IN FROM ENDWALL) TRUSS/BRACING PLAN SCALE: (2) 20d R.S. NAILS IN OVERHANG FRAME 2x4 BEV, PURLIN TOE NAIL OVJ TO OVERHANG NAILER WITH (1] 16d R.S, NAiL EACH SIDE OVERHANG FRAME - 2x6 OVERHANG NAILER I. DETAIL 1 SCALE: 1 1/2": 1 '-0" 60' - ~Xl0 INC.1 SYP) END RAFTER ASSEMBLY (7) 20d R.S. NAILS -- 3-2X6 CORNER COLUMN 60' 2x10 (NO.1 SYP) ~ END RAFTER ASSEMBLY~ _1o-2ooN ADDITIONAL 2x6 NAILER ~ 20d R,S. NAIL THR ~ // · j 2x4 TRUSS TIE ~ ~ 2x4 TRUSS TIE TO ENDWALL DETAIL #3 2-2x6 END COLUMN EXTENSION OR UPRIGHT ASSEMBLY NAILED TO END RAFTER ASSEMBLY AS SHOWN AND TO EACH INTERSECTING WEB. FASTEN TO HEADER AND FRAMING MEMBER WITH (2) 16d R.S. NAILS iNTO EACH END COLUMN EXTENSION MEMBER OR UPRIGHT. DETAIL 2 SCALE: 1 1/2"=, 1'-0" 2x4 TRUSS TIE 60d R,S, NAIL .OWER TRUSS CHORD I1) #9xlr' TRU-GRIP sCREWS ON PEAK SIDE AND/'~''''/~'///~ (2) ON EAVE SIDE IN HOLES SHOWN. (JOINT MUST BE TIGHT BEFORE FASTENING CLIPS) 2x4 TRUSS TIE DETAIL CALLED 20 ga. GALVANIZED PURLIN CONNECTOR CUTCHOGUE, NY 08 NO,12810813 II I 7 ~DRAWN B~' KLEIN DA TE: 03/27/08 CHECKED BY,' SOG DA TE: OB/12/0B REVISED DATE: REVISED DATE: REVISED DATE: -- ~REVISED DAT£' -- · SCALE: AS NOTED SHEET NO, ~, S2 oF S7 BC EP SL HO 1-3-8 9- 2-13 9-2-13 6-10- 7 7-3-0 22-11-14 6-10-10 7-3-0 29-10- E 6-10-10 7-3-0 36-9-2 6-10-10 7-3-0 43- 7-12 6-10-10 7-3-0 50-6-3 6-10- 7 9-8-14 59-9-0 SL 16-6-5 HO1 3-8 11-3-0 4.034I- WG1 8 #2.5x5 Wl C &18G-MN 18-7,5xl 6.25 & 18G-MN 1B-6.25x 12.5 B1 #5x&2B 0,1004 R T2 W4 W~ D #7.5xl 0 W5 3,963 [-- #18G-MN18~10xl6.25 E WEB STIFFENERS --] 3,963 F W6 W8 W7 #7.5x10 T3 W9 Wl0 #8.75x8.~5 #8,75xl 1.25 N #8.75xl 1,25 #8175x8,75 18G-MTSH-Sx16 B2 O M 18G-MTSH~Sx16 K p L 7. 7-8 E I 50508 40 00F40 00 50508 17- 9- 5 - 250408 291008 ~ 340408 391a00 7-7-8 ~'~ G Wll H #2.5x5 WG2 T4 J 4.034 #5x6,25 J B3 &18G-MN 18-6,25xl 2.5 &l 8G-MN18-11.25x17,5 59-9-0 TRUSS DESIGN LOAD = 270 PLF REQUIRED TRUSS LOAD = 19 LiVE LOAD 18 ,PSF DEAD LOAD 4 PSF CEILING LOAD PSF TOTAL LOAD 19 PSF PSF AT 7'-6" D.C.= 143 PLF 59-%0 TRUSS DESIGN SPECIFICATION; Truss has been designed by computer using Rebblns Engineering Software and specifications of recognized engineer]ng principles. Trusses are manufactured by Morton Buildings, inc. LUMBER SPECIFICATION {2001 NbS for Wood Construction): Lower Chord -- No, 1 K.D, - 19 or 2400f - MSR 2,0E Southern Pine Top Chord --~ No. 1 K.P. - I 9 or 2400f - MSR 2,OR Southern Pine Web Members -- No, 1 K,D. - 19 Southern Pine TRUSS PLATE SPECIFICATION {ICBO Evaluation repod NO. 2929): ASTM A-653, Grade A 20 Ga. and 18 Ga, where noted, galvanized steel Modon truss plates identified by a hexagon stamped every 1 114" along the center of the plate. 60' S.C. 2090 TRUSS SCALE; ~jl~I= 1'-0" 7-7-8 49-7-3 6' WIDE (ZONE 2 & 3J 2x4 P 6' WIDE (ZONE 2 & 3} HEADLOK .19"x 6.0" FLATHEAD LAG SCREW 60' WIDE BUILDING PURLIN LAYOUT SCALE: 1/2"= 1'-0" NOTE: HEADLOK .19" x 6.0" FLATH FAD LAG SCREW TO BE USED ON ALL PURLINS, 2x4 PURLIN HEADLOK .19'~(6,0" FLATHEAD LAG SCREW (ICC-ES REPORT ESR-1078) (1) #9x1" TRU-GRiP SCREW ON PEAK SiDE AND (2) #9x1" TRU-GRIP SCREWS ON EAVE SIDE DP PURLIN IN HOLES SHOWN (JOINT MUST BETIGHT BEFORE FASTENING CLIPS 2x4 BUTTED PURLIN DETAIL IPURLIN CONNECTED WITH 6" HEADLOK F~LATHEAD LAG SCREW) SCALEE: 1 1/'Z'= 1'-9" 20 GA. GALVANIZED PURLIN CONNECTOR U n O II I II I 7 U U II I ,_ DA TE: 03/27/08 CHECKED BY: SaG OA I"E; 05/12/08 ~?EVISED DATE: ---- J~EVISED DATE., --- FR: o5,,°s · SCALE.'AS NOTED SHEEI' NO. ,. S3 o~ S7 (ZONE 3) (ZONE 2) (ZONE ZONE B (ZONE 3) ~ IZONE2)~ (ZONE3)~ 34'-6" 65'-0" 65'~)" 6' WIDE (ZONE 2) [ONE 2 & 3) (ZONE 1 ) 34,.6,r 3'-6"x3'-6" CUPOLA (NON-FUNCTIONAL) 6' WIDE.. 183' WIDE (ZONE 4) · !~ J '(ZONE 5) I ~7L6'' ~ 25"0" 72"6" ~ ~ = ~, ~ O 6,0' WIDE (ZONE E) 6' WIDE (ZONE 2 & 3) (ZONE 1) WIDE (ZONE2&3) NORTH ELEVATION 6.0' WIDE ~ 6.0' WIDE (ZONE 2 & 3} /'~' ~/~'~. (ZONE 2 & 3) 6,0' WIDE (ZONE 2 & 3) 4E.0' WIDE (ZONE 6,0' wro~ ,~,o' w,DE ~ ~8.o' wiDE IZONE ~1 (ZONE E) (ZONE ,5) 6,0' WIDE (ZONE 5) 30'-0" ], 30'~)" b 0 -~ WEST ELEVATION 25'-0" EAST ELEVATION kEILE TRIM :L SIDING CORNER TRIM DN TRIM \INSCOT 6' WIDE (ZONE 2 & 5" O,G, GUTTERS HERIB STEEL SIDING rRtM STEEL WAINSCOT BASE TRIM HI-RIB STEEL SIDING T#21 CORNER TRIM T# 167 TRANSITION TRIM HI-RIB STEEL WAINSCOT T#)67 BASE TRIM · CUTCHOGUE, NY II l II I I ~D,~AWN B~' I(LEIN DATE: 33/27/08 ,~EVISED DATE., .-- ~EVISED DARE;I 6' WIDE fZONE $) NOTE: DOOR AND WINDOW LOCATIONS ARE TAKEN FROM THE EXTERIOR FACE OF THE NAILERS AND A~O THE CENTER OF THE DOOR AND WINDOW UNITS, VERIFY ALL LOCATIONS WITH THE OWNER. 183' WIDE (ZONE 4) SOUIH ELEVATION 6' WIDE (ZONE 5) oS, IL,:,, o8 I3CALE: AS NOTED SHEET NO. S4 o~ S7 ROOF STRUCTURE FASTENING SCHEDULE ---"'--- ~ #9 x 8" (]) ~RIDGE TO RIDGE BASE T~IM #9 X 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1'-0" 0,¢,) ~ RIDGE BASE TRiM TO 2X4 PURLINS ~) HI-RIB STEEL TO 2x4 PURLINS #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS AT EVERY HI-RIB (1 '-0" o,c.] ~) 20 ga. GALVANIZED PURLIN CONNECTORS #9 x 1" TRU-GRIP SCREWS ~) 2x4 PURLINS TO TRUSS HEADLOK ,19"' x 6,0" FLATHEAD LAG SCREW (2) lJ2"x5 1/2" MACHINE BOLTS (~) B0' STRAIGHT CHORD TRUSS TO COLUMN (12) 0.177"x 4" (20d) RING SHANK NAILS WALL FRAMING FASTENING SCHEDULE COLUMN STILT (14 GA.I TO COLUMN (16) 0,148"x 2" (Bd} STAINLESS STEEL RING SHANK NAILS B1M BASE ANCHOR TO COLUMN 0.177" x 2-1/2" STAINLESS STEEL NAILS (4) PER ANCHOR 2x8 SPLASHBOARD TO COLUMN (4) 0.177" x 4" J20d} STAINLESS STEEL RING SHANK NAILS @ SpIJCE/ (si 0,177" x 4" (20d) RING SHANK NAILS @ STANDARD CONNECTION 2x6 NOTCHED NAILER TO COLUMN (4) 8,148" x 3-1/2" (16d) NAILS @ SPLICE/(3) 0.148" x 3-1/2" (16d) NAILS @ STANDARD CONNECTION 7Jl 6" OSB TO SPLASHBOARD & NOTCHED NAILER 0,099" x 1-1J4" ASBESTOS SIDING NAilS 2x4 NAILER TO COLUMN (4) 0.148"x 3-1/2" (16d) RING SHANK NAILS @ SPLICE/(3) 0,1148" x 3-112" (1Bd) RINg ,SHANK NAILS @ STANDARD CONNECTION END RAFTER ASSEMBLY TO 2-2x6 END COLUMN EXTENSIONS (10) 0.177"x 4" (20d) RiNG SHANK NAILS 2x4 PURLIN TO END RAFTER ASSEMBLY HEADLOK ,]9"x 6,0" FLATHEAD LAG SCREW '" c ~ #9 x 2" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNA~L DRIVE SCREWS AT EVERY HI-RIB (1 ~0 o..) HI-RIB STEEL TO NAILERS ~~~(~ SOFFIT TO WALL INSERTED JN PRE-FORMED ,SLOT IN SOFFIT/HI-RIB CAP SOFFIT TO FASCIA T-50 MONEL STAPLES (2) PER PIECE CUPOLA CAP TO CUPOLA ROOF (4) 1/4" x 1" PLATED MACHINE BOLTS AND LOCK WASHERS CUPOLA ROOF TO CUPOLA SIDES PRE-FORMED CRIMPED METAL CONNECTIONS AND (8) #9 ~ 1" STAINLESS STEEL RUBBER WASHER PANHEAD INTERNAL DRIVE SCREWS ~ ~ #9~ 1" STAINLESS STEEL RUBBER WASHER pANHEAD INTERNAkL DRIVE SCREWS J4)~ER SiDE (16) TOTAL CUPOLA SID~ TO CUPOLA BASE FRAME ~ 1-7/B" GUN NAILS @ 6" o,c. OSB CUPOLA SUPPORT TO TREATED BEVELED BLOCK 0.148" x 3-1J2" (J 6d) RING SHANK NAILS @ B" o,c. , ,,, TREATED BEVELED BLOCK TO 2x4 CUPOLA BLOCKS l J4" × 4-1/2" LAG SCREW W/1/4" FLAT WASHEP~ AT EVERY HJI-RIB I1 I-O" C.C.) II I 2x4 CUPOLA BLocKS TO FRAMING CLIPS (2) 0.135" x 1-1/2' RING SHANK NAILS (2) 0.135" x 1-1/2" RING SHANK NALS IN SIDE OF PURLIN AN~D (2] 0.135' x 1-1/2" RING SHANK NAILS IN TOP OF Eg~LIN FRAMING CLIPS TO PURLINS CUPOLA ROOF "~'~'~UPOLA SIDE FRAME CUPOLA BASE TRIM -- FF2000 HI-RIB ,~ FIRST ROW 2X4 PURLINS~, t ~ CENTERLINE OF CUPOLA 6" 6" ~, 1'-O" ~' PF~,K PURLIN BLOCKS / '~ 'x~x Bg~ FR CUPOLA FRAMING DETAIL SCALE: 1" = 1'-~' 3'6 x 3'6 Cupola Non-Functional (2x4 Purlins) BASE FRAME T#167 REATED BEV. BLOCK BLOCKS , FRAMING CLIP~ TRUSS CUTCHOGUE, NY II I II I 7 DA TE." 03/27/08 DATE: 05/12/08 REVISED DATE; -.. REVI,SED DATE; -- REVISED DATE: -.. ,REVISED DA TE: -.. oS, olS S5 CE S7 T#1 ~) FF2000 HI-RIB STEEL ~® 2x4 PURLINS @ 24" O,C. (NO. 2 SPF] 2x4 BEV. PURLIN FILLER STRIP 2x6 BEV, FASCIA 5" O,O, GUTTERS @~ SOFFIT HI.RIB/SOFFIT CAP 2x6 OVERHANg NAILER (2) I/2~($ lj2" M, BOLTS & (12) 20d R.S. NAILS NEADLOK .19" x B,0'j FLATHEAD LAG SCREW 60' 2090 S,C. TRUSS ~) ~KYHAR HI-RIB STEEL 14'-0" gRADE TO HEEL 2'44 NAILERS @ 20" O.C, ~ 2100 MSR SPF 18" LOWEST FINISH GRADE 3-2X8 LAMINATED COLUMN 2X2 VERTICAL BLOCKING AT COLUMN LOCATION T#167 TRANSITION TRIM 2x6 NOTCHED NAILER KYNAR HI-RIB STEEL WAINSCOT ?'/1B" OSB PROTECTIVE LINER B/4x6 BLOCK T# 1~S7 BASE TRIM ROW 2x8 TREATED SPLASHBOARD 81M BASE ANCHOR ," MINIMUM COMPACTED GRANULAR SASE 24"~ 224M (14 GA,} COLUMN STILT ~ 10" THICK MINIMUM READI-MIX CONCRETE BELOW BOITOM OF LOWER COLUMN WITH ADDiTiONAL READI-MIX BACKFILLED TO 4" BELOW GRADE. PLACE CONCRETE BELOW AND ABOVE BOTFOM OF LOWER COLUMN IN ONE OPERATION, TRUSS IN COLUMN SADDLB LAMINATED COLUMN GABLE PURLIN FLASHING T# 1B GABLE TRIM 2x6 FASCIA FF20O0 HI-RIB STEEL PURLINS @24" O,C, T# 194 TRIM SOFFIT HI-Rib/SOFFIT CAP TRIM ~ 60' - 2x10 (NO,1 SYP) ADDL, 2x6 NAILER 3-2x~ LAMINATED COLUMN 2x4 TRUSS TIE ENDWALL SECTION B SCALE: 1 [2" = I 2x6 UPRIGHT KYNAR HI-RIB STEEL T#71 TRACK COVER B1M TRACK 3x4 TRACK BLOCK 1 1/2'~(2'~ BLOCK BT#74 T#] 71 JAMB TRIM 2x10 TRACK GIRT TO GRADE 2x3 JAMB (BEYOND; BOTFOM 2' TREATED) 3-2x6 JAMB COLUMN(BEYOND) W/2x6x7' TREATED SPLICE STIFFENER SLIDING DOOR HEADER SECTION C [4) 0,13B"x 2 1/4" R,W. NAILS OR lsd R,S, NAILS (1) 20ct R,S, NAIL THROUGH STRAP & INTO BRACE 2' END BRACE STRAP W/PRE-PUNCHED HOLES (BEND TO FITI FASTENED W/ (3) 0,140 x 1 1/2" R.S. NAilS -- 2x6 DIAGONAL BRACING FASTENED TO COLUMN W/(4J l~ct R,S, NAILS 60' 2090 S,C, TRUSS (2) 60d R.S. NAILS IN OVERHANG RAFTER 2x4 PURLIN CUT TO FIT OVERHANG FRAMES 6"MESH 2X6 OVERHANG NAILER KYNAR HI-RIB STEEL 2xl0 HEADER (NO, 1 SYP) 60' 2090 S.C. TRUSS T#71 TRACK COVER 4 1/2" CUSTOM 346L TRUSS HANGER FASTEN TO TRUSS W/(14) 1 1/2"R,S. NAILS $1M TRACK &/1) I/2"7~ 1/2' M, BOLT FASTEN TO 3x4 TRACK BOARD HEADER W/(8) 20d R.S, NAILS IN FACE & (4) 20d 1 1/2"x2" BLOCK R.S. NAILS IN TOP 13'-7 1/2" T#74 TRACKBOARD TRIM GRADE TO BOTTOM T# 172 JAMB TRiM OF TRACK GIRT 5 1/4"x 19 1/2" GLU-LAM D. X3 JAMB (BEYOND; HEADERS (2400lb) · o~roM 2' TREATED) J NOTE; DOOR HEIGHT = GRADE J 3-2x8 LAMINATED JAMB COLUMN TO HEEL HEIGHT ~ 4 ]/2", J BEYOND W/AN ADDITIONAL 2x8 TREATED LAMINATE FOR HEADER SUPPORT SLIDING DOOR HEADER SECTION D SCALE: l": IL0" TOP OF BEAM HANGER BITS DOWN ON SQUARE CUT COLUMN iAM HANGER TO COLUMN FROM OUTSIDE WITH (3) S,S. COLUMN ANCHOR NAILS SADDLE BLOCK NAIL HANGER TO BEAM FROM iNSIDE WITH S.S. COLUMN ANCHOR NAILS 3-2x8 LAMINATED COLUMN -- GLU-LAM BEAM ADDITIONAL TREATED LAMINATE INSIDE VIEW BEAM HANGER SIDEWALL SECTION A SCALE: 1/2"= 1'43" NOTE: FOOTINGS ARE DESIGNED FOR A 2000 PSF SOIL BEARING CAPACITY, LOCAL CONDITIONS MAY REQUIRE MODIFICATIONS, CONCRETE FLOOR NOTES 1. 3500 PSI, 5 1/2 BAG MIX CONCRETE 2, SLOPE GRADE AWAY FROM BUILDING @ 1" PER FOOT FOR A MINIMUM DISTANCE OF I0' PLUS OVERHANG WIDTH 3. A VAPOR RETARDER IS NOT MANDATED PER IBC SECTION 1910 EXCEPTION 3, UNLESS THE FLOOR WILL BE COVERED BY MOISTURE SENSITIVE FLOORING MATERIALS OR IMPERMEABLE FLOOR COATINGS OR WHERE THE FLOOR WILL BE JN CONTACT WITH ANY MOISTURE SENSITIVE EQUIPMENT OR PRODUCT 4. CONTRACTION JOINTS UNIFORMALLY SPACED 12' C.C. OR LESS NOTE: · IDENTIFIES ITEMS THAT ARE NOT PROVIDED BY MORTON BUILDINGS, INC, OR MORTON BUILDINGS' SUBCONTRACTORS AND ARE THE OWNER'S RESPONSIBILIT'(, NAIL 2x10 GIRT TO BEAM WITH 20d GUN NAILS @ 4" O,O, STAGGERED 2X3 JAMB *NOTE: VIEWS ARE SHOWN WITHOUT OVERHANGS 5 1/4" GLU-LAM JAMB DETAILS OUTSIDE VIEW 1/2" WOOD SCREWS @ 10" O,C, FASTENED THROUGH THE ALUMINUM DOOR SIDE JAMBS INTO THE 2)(4 ROUGH FRAMING. PRE-DRILL HOLES IN ALUMINUM DOOR JAMB TO ACCEPT WOOD SCREWS, SCREWS ARE NOT REQUIRED IN THE HEAD OR THE SILL, HEAD FLASHING 1/2'x12'' LAGS FASTEN 2x10 TO COLUMN W/(14) 20d R.S. NAILS #8 x 3 ~/2" WOOD SCREWS SPACED AS SHOWN ABOVE TO AVOID DOOR INSTALLATION SCREWS STILT ISOMETRIC LAMINATED COLUMN FASTENED TO COLUMN AT EACH CORNER WITH (4) .148"~x2" STAINLESS NAILS. (1S TOTAL NAILS PER COLUMN) 14 GA, CHANNEL WITH 1/4" PLATED RIVET TO SUPPORT ANGLE UNDISTURBED SOIL STILT NOTES 1, INSTALL PRESSURETREATED LOWER COLUMN WITH STILT IN THE AUGURED HOLE, 2, POUR 9" MINIMUM THICKNESS OF READI-MIX CONCRETE INTO THE HOLE AS SPECIFIED. 3, BACKFILLAND COMPACTTHE ANNULAR SPACE AROUND THE COLUMN TO GRADE WITH SOIL AUGURED FROM THE SITE. INTERIOR EXTERIOR NAIL KEY 0.148" x 4" (20d) NAILS 0.131" x 3 1/2" HOT DIPPED GALVANIZED (HOG) RING SHANIK NAILS 3-2x6 COLUMN SPLICE FASTENING IDETAIL SCALE: 1/2'= 1'-0" INTERIOR EXTERIOR NAIL KEY 0~148"x 4" (20d) NAILS -- I '10.131" x $1/2" HOT DIPPED GALVANIZED (HDC} RING SHANK NAILS 3-2x8 COLUMN SPLICE FASTENING DETAIL SCALE: 1/2" = 1'-0" DOOR JAMB 2'~4" ROUGH FRAMING WALK DOOR JAMB DETAIL OSB PANEL IS 1' WIDER THAN THE WIDTH OF TItE DOOR FROM OUTSIDE OF TRIM TO OUTSIDE OF TRiM NOTE: DOOR FANEL AND WINDOW PROTECTION DETAILS ARE FOR INSTALLATION INSTRUCTIONS ONLY, AND ARE NOT PROVIDED OR INBTALLED BY MORTON BUILDINGS' INC. OR MORTON BUILDINGS' SUBCONTRACTORS AND ARE THE OWNERS RESPONSIBILITY. HEAD FLASHING 7/1S" OSB PANEL DOOR SLAB WINDBOURNE DEBRIS PROTECTION - WALK DOOR WALK DOOR SECTION CUTCHOGUE, NY JO8 NO. 128-0813 0 II I II I 7 KLEIN · DA TE; 03/27/08 iDA TE: 05/12/08 REVI3ED DATE,' --. REVISED DA TE: --- '~TE.'--- S6 S7 3-2'~x6' LAMINATED JAMB COLUMN (BEYOND) GRADE VERTICAL "1" RAIL (0.07" WEB, 0.09" FLANGE) INTERMEDIATE DOOR GUIDE DOUBLE TOP "D" RAIL (lB GUAGE) HORIZONTAL /~ "t" S.S. RAIL (0.06" WEB, 0.08" FLANGE) 13E LATCH ROD \ 13E LATCH ROD ,~ VERTICAL "1" RAIL (0.07" WEB, 0,09" FLANGE) CENTER DOOR GUIDE -- 24'47' INTERMEDIATE DOOR GUIDE \ STRUT HORIZONTAL 'T' iNTERMEDIATE RAIL (0,06" WEB, 0,0B" FLANGE) HORIZONTAL "1" iNTERMEDiATE RAIL (0,06" WEB, 0.0B" FLANGE) VERTICAL "1" RAIL (0.07" WEB, 0.09" FLANGE) LATCH HANDLE DOUBLE BO]TOM (16 GUAGE) DOUBLE SLIDING DOOR FRAME (TWIN PANEL) CENTER DOOR GUIDE 14B AlS DOOR GUIDE HAS A BUILT-IN STOP FOR ALUMASTEEL DOORS SO STUB COLUMN MUST BE EXACTLY OENTERED IN DOOR OPENING INTERMEDIATE DOOR GUIDE DOOR GUIDE DETAILS JAMB COILUMN LATCH HANDLE 47E AlS LATCH STRIKE pLATE 1264 8" HOOK HORIZONTAL INTERMEDIATE "1" E INSTRUCTIONS 1. SCREW NUT ONTO HOOK, 2, SCREW HOOK INTO LATCH BODY. JAMB DETAIL 1265 JAMB LATCH BODY LATCH HANDLE F INTERMEDIATE RAIL ~iII TRACK GIRT TO GRADE ku RAIL THICKNESS CHART HEAVY STANDARD VERTICALj J HORIZONTALj FLANGE WEB J FLANGE WEB HORIZONTAL - WE~ FLANGE VERTICAL WEB · 090" r FLANGE DOUBLE TOP "D" RAIL -- [IJ (lB GUAGE) Illl 3-2"x8" LAMINATED ~ ~ 13'-7 /2" JAMB COLUMN m TRACK JRT (BEYOND) ii ~ TO G~ VERTICA' '1" RAIL ~ HORIZONTAL (0 / WEB "lIIS.S. RAIL j (0.06" WEB, (0.0~' WEB, j O.0B" FLANGE) 0.09" FLANGE) 18E LATCH ROD ~ HORIZONTAL "1" ~ iNTERMEDIATE RAIL 13E LATCH ROD ~ I),08" FLANGE) (0,07" WEB, HORIZONTAL "1" 0.09" FLANGE} INTERMEDIATE RAIL _ (0.06" WEB, 13E LATCH ROD ~ 0,0B" FLANGE) LATCH HANDLE ~ DOUBLE BOTTOM ~ INTERMEDIATE ~DOOR GUIDE CENTER DOOR GUIDE ~, INTERMEDIATE ~DOOR GUIDE (16 GUAGE,~ GRADE 5'-7 1/2" 5'-7 1/2" 5'-7 1/2" 5'-7 1/2" CUTCHOGUE, NY - U II I 7 DATE., [33/27/08 DA TE: 35/12/08 REVISED DATE., --. REVISED DA TE: -- ~EVISED DATE: ,.-- 13E LATCH DOUBLE SLIDING DOOR FRAME {TWIN PANEL) I $CALE: AS NOTED LATCH ROD DETAIL SHE~NO. S7 o~ S7