Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33873-Z Bldg C
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: z-33184 Date: 08/01/08 THIS CERTIFIES that the build{ng MOTEL BUILDING "C" Location of Property: 61475 CR 48 (HOUSE NO.) (STREET) (HAMLET) County Tax~4ap No. 473889 Section 45 Block i Lot 2.1 Subdivision Filed Map No. LOt No. GREENPORT conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 7, 2008 purs,,~nt to which Buil~ng PeXlnit No. 33873-Z dated MAY 7, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is MOTEL WITH EXTERIOR DECKS, (BUILDING C), AS APPLIED FOR PER ZBA # 4942, DATED 3/20/03. The certificate is issued to BREEZY SOUND CORP (OWNER) of the aforesaid building. SOFk~)I~K CO~TY DEPANT~T OF HE~J~TH AImPRO~I%~ C10-02-0015 ~.RC~ICAL C~TIFICATH NO. 8275 PI~]~E~S ~KTIFICATION DA'r~ 06/05/08 BETSAND PLUMBING 07/31/08 05/27/08 Rev. 1/81 Form~No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPAN(~ ~lc~ This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commemial building, industrial building, multiple residences and similar buildiugs and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. New Construction: Old or Pre-existing Building: LocationofProperty: ~.~ \ gSx'~]~ C_~['d- ,~t{>_) House No. Street C. Fees I. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. (check one) Owner or Owners ofProperty: \ ~_ff]h4x, k.~(x~\ ~-,..,D~ "-'~,~.fz-~,,-X,.~l'~w<.. Suffolk County Tax Map No 1000, Section q _t~ Block Filed Map. Applicant: Underwriters Approval: Subdivision Pe~t No. ~ ~)"3 "~ Health Dept. Approval: Date of Permit. Hamlet Lot ..3./ Lot: Plarming Board Approval: Request for: Temporary Certificate Fee Submitted: $ Z-~,°° Final Certificatc: ~ (check one) "-~pplicant Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33873 Z Date MAY 7, 2008 Permission is hereby granted to: SOUND CORP BREEZY PO BOX 815 QUOGUE,NY 11959 for : AMENDED FOUNDATION PERMIT TO CONSTRUCTION OF MOTEL BUILDING "C" AS PER ZBA, PLANNING, AND SCHD AS APPLIED FOR THIS REPLACES BP# 31685 at premises located at 61475 CR 48 County Tax ~4ap No. 473889 Section 045 pursuant to application dated MAY Building Inspector to expire on NOVEMBER Fee $ 3,600.00 GREENPORT Block 0001 Lot No. 002.001 7, 2008 and appro~d by the 7, 2009. ORIGINAL Rev. 5/8/02 ;FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31685 Z Date DECEMBER 20, 2005 Permission is hereby granted to: SOUND CORP BREEZY PO BOX 815 QUOGUE,NY 11959 for : CONSTRUCTION OF A FOUNDATION FOR MOTEL BUILDING "C" AS PER ZBA, PLA/~NING & SCHD AS APPLIED at premises located at 61475 CR 48 County Tax Map No. 473889 Section 045 pursuant to application dated AUGUST Building Inspector to expire on JUNE GREENPORT Block 0001 Lot No. 002.001 18, 2005 and approved by the 20, 2007. Fee $ 1,562.00 ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31685 Z Date DECEMBER 20, 2005 Permission is hereby granted to: SOUND CORP BREEZY PO BOX 815 QUOGUE,NY 11959 for : AMENDED FOUNDATION PERMIT TO CONSTRUCTION OF MOTEL BUILDING "C" AS PER ZBA, PLANNING AND SCHD AS APPLIED FOR at premises located at 61475 CR 48 County Tax Map No. 473889 Section 045 pursuant to application dated AUGUST GREENPORT Block 0001 Lot No. 002.001 18, 2005 and approved by the Building Inspector to expire on JUNE 20, 2007. Fee $ 3,600.00 ~~~ ORIGINAL Rev. 5/8/02 Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8275 Date: 5/27/08 Issued to: Cliffside Resorts Address: Route 48 (Building-C) Introduced By: Modern Electric East Village: Greenport License #: 4253-E Residential Commercial [] The following was examined and approved up to the above date and found to be in compliance with the NEC.' Attic [] I'~ Floor [] 2"~ Floor [] 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixlures G.F.h Fan Heaters Exit/Emergency Signs 12 13 58 8 6 I~ans Dishwasher ~rasher/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust Fans 4 4-Gas Furnace ()il (;as Heat Zones Whirlpool Bell Transformers yes II Final Insp. Meter Amps Phase Motors II 5/27/118 I 200A UG II Other Equipment: I-Time Clock,2-Photo Cells House Wiring Building-C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8217 Date: 5/7/08 Issued to: Cliffside Resorts Address: (CI01) Route 48 Introduced By: Modern Electric East lnc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic Ist Floor [] 2nd Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 17 22 13 5 I 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I l-Cook Top Furnace ()il Gas Heat Zones Whirlpool Bell Transformers I yes II Final lnsp Meter Amps Phase Motors Il 5/7/08 I I00A, I II Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York · 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8218 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C102) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic Is~ Flobr [] 2nd Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 21 26 16 5 I 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I 1-Cook Top 1 Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes IIFinal Insp. Meter Amps Phase Motors II 5/7/08 1 I00AI I II Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York · 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8219 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C103) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic 1~t Floor [] 2n~l Floor 3ra Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 24 24 19 5 I I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I l-Cook Top I Furnace ()il Gas Heat Zones Whirlpool Bell Transformers 1 yes 1 Final [nsp. Meter Amps Phase Molors II 5/7/08 I 100A I Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8220 Date: 5/7/08 lasued to: Cliffside Resorts Address: (C104) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic Ist Floor [] 2"a Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.[. Microwave Wine Cooler 22 23 16 5 1 I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I 1-Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes I [ Final lnsp. Meter Amps Phase Motors Il 5/7/08 1 ,00A l II Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Ii Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11951 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8220 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C105) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic Ist Floor [] 2nd Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 22 25 16 5 I I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust 1 I-Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes I Il Final lnsp Meter Amps Phase MolorS II 5/7/08 1 I00A I Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8221 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C106) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic !~t Floor [] 2"a Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 23 26 19 5 I I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top I Furnace Oil Gas }teat Zones Whirlpool Bell Transformers I yes I II Final Insp Meter Amps Phase Motors ]l 5/7/08 I I00A I Il Other Equipment: I-Zone Ccntral A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box $49, Aquebogue, New York + 11931 Tel: 631-$91-3097 Fax: 62;I-$91-3098 Application: 8222 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C107) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic 1st Floor [] 2"a Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 20 26 16 5 I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I -Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes I I Final Insp Meter Amps Phase Motors II 5/7/08 ' ,00A , Other Equipment: I-Zone Ccntral This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8223 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C108) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic Is* Floor [] 2nd Floor 3rd Floor Garage Conversion Basement [] Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 17 21 13 5 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I 1-Cook Top 1 Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes 1 II Final Insp. Meter Amps Phase Motors II 5/7/08 I 100A I II Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8224 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C201) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] 1st Floor 2nd Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.[. Microwave Wine Cooler 18 23 16 5 1 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust 1 1-Cook Top I Furnace Oil (Jam Heal Zones Whirlpool Bell Transformers I yes 1 II Final Insp. Meter Amps Phase Motors II 5/7/08 1 ,00A I II Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8225 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C202) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] Ist Floor 2na Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 18 23 16 5 I I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top 1 Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes I II Final Insp. Meter Amps Phase Motors II 5/7/08 i 100A I Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8226 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C203) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] Ist Floor 2nd Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 20 22 17 5 I 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top 1 Furnace ()il Gas tteat Zones Whirlpool Bell Transformers I yes I II Final Insp Meter Amps Phase Motors Il 5/7/08 I IOOA I II Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box $49, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8227 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C204) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] Ist Floor 2"a Floor [] 3ra Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 20 25 15 5 I I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top 1 Furnace Oil Gas tteat Zones Whirlpool Bell Transformers I yes I [ Final lnsp Meter Amps Phase Motors II 5/7/08 I I00A I Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-$91-3097 Fax: 631-$91-3098 Application: 8228 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C205) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] Ist Floor 2ntl Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 20 23 15 5 1 I Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes 1 II Final Insp Meter Amps Phase Motors II 5/7/08 i 100A I Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8229 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C206) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] Ist Floor 2~a Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I. Microwave Wine Cooler 20 24 17 5 1 1 Fans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes 1 II Final Insp. Meter Amps Phase Motors Il 5/7/08 I 100A I II Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York · 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8230 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C207) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] I~t Floor 2nd Floor [] 3ra Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures G.F.I Microwave Wine Cooler 18 23 17 5 I 1 I'ans Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I-Cook Top I Furnace Oil Gas Heat Zones Whirlpool Bell TransFormers I yes 1 II Final lnsp. Meter Amps Phase Motors II 5/7/08 I I OOA I Other Equipment: l-Zone Central A/C This certificate must not be altered in any manner Nassau Suffolk Electrical Inspections,Inc. P.O. Box 549, Aquebogue, New York + 11931 Tel: 631-591-3097 Fax: 631-591-3098 Application: 8231 Date: 5/7/08 Issued to: Cliffside Resorts Address: (C208) Route 48 Introduced By: Modern Electric East Inc. Village: Greenport License #: 4253-E Residential [] Commercial The following was examined and approved up to the above date and found to be in compliance with the NEC: Attic [] 1st Floor 2no Floor [] 3rd Floor Garage Conversion Basement Hot Tub Addition Detached Garage Pool Switches Receptacle Fixtures GFI. Microwave Wine Cooler 18 23 16 5 I I Fans Dish'rasher Washer/Amps Dryer/Amps Oven Range/Amps Carbon Monoxide 2-Exhaust I I -Cook Top 1 Furnace Oil Gas Heat Zones Whirlpool Bell Transformers I yes I II Final Insp Meter Amps Phase Motors II 5/7/08 , 100A 1 Other Equipment: I-Zone Central A/C This certificate must not be altered in any manner 08/05/2008 13:37 FAX 8313697746 L3M_DEVELOPMENT ~004/008 Town Hall, 53095 Main Road P.O. Box 11'79 Southold, New York 1197t-0959 'Fax (031) 755-9502 'lelephone (63) 765 802 BUILD ING DEPARTMENT TOWN OF $OUTHOLD CERTIFICATION Date: Building Permit No, ~.~% ~-~ ~ (Pleare prhlt) (Pleasc print) I certily that the solder used in the Water supply system contains less than 2/10 of I% lead, Sworn fo befhle me this fit h ... June 20 08 (P lul]'lber~ S." J gtl.'-tt u r e) Notary Publu;,. Suffolk Counlv Elleen M. Roache Notary Public, State of New York No. 4826942 Qualified in Suffolk County Commission Expires January 31, BOARL~ OF TOWN O:F SOUTHOLD FINDINGS, DELIBE~RATIOr,.% AND DETERMINATION MEETIN',.3 OF- ~.,/~RCH 20, 2003 ~]003/014 53095 Main RoAd P-O. Box Il?9 $outholc[, Hew 'York 11971-0959 TeJopbon~ ~631) 765-1 h t tp://$ o tt~ol~p~.a~lllgOrk.n ~ I Soethold Tows Clerk ,',9~1. No. 4942- BJ~EEZ'Y SOUND CO,~~, Pr~',certy Location: North Side of C.R 4& a~k~a North Road (opposite San N~.~roin~ Horoe). Greenport; Parcsl 1000-~5-01.,2.1, AF~ ALi~L~: Applicant is requesting a Special Exception under ~ec~on 10t.~61B(4), for permission to estal:r~h new $6-unit motel with motel office, pool house for motel guests, and motel-manager's aparb'nent unit as shown on the diroensic~al plan prepared by Barrett. Bonacci and VanWesle, P.C. dated 10/3/01, revised 8/2/02. P~K)PERTY FACTS~DESCRIPTION: ]'ne appii.c~at.'s 7.13-acm parcel is unimproved and :s located on the north side of C.R. 48, a/'rJa North Road, in Greenport, and is Io,:at~d in the Resort- Residential (RR) Zon~; D,s[4ct. F.~(D__ING~ :)F FACT ~'~-A Zoning Board of AppeaJ$ held a ,~bli; hearing on this applica~n on October 17, 2~'32. and January 16, 2003, at which & :i,g written and oral evidence were presented. B~s ~ d upon all testimony, docuroentatJo& personal inspeclJon ol~ the property, and other evL:l~nc, e, the Zoning Board finds the follcwlng i'acls to be true and relevant: CC, F.,E PROVISION: Code Section 100-$1~/,4) provides thai the following are permitted by '~pecia[ Exception approval from the BOard of AppeaLs, subject to site plan approval by ~h~ Planning Board: Transient hotels or mulch,, resort hotels or motels or conlsrsncs ~cnitle,s. pn~vlde~ thai the ~oltowing requirements are met: Ca) MiNmum parcel~s;:.e shall be five/,13) Cb) The maximum r, umb~' ~f gu~.~t u!~a~ shall be: [1] One (1) u~t per six Ih,~aand (6.000} square tee[ of la~d without public or aB~. [2] One (1) unit per ~O.~r thousand (4.000} square f~J: o~ had with public (c) No m~. ~fla~ment or Io~,~,~e~r sy~am shall be au~e bom (d) The maximum size of e g~es{ unit ~haN be slx hundred (it00) Square feet. ~8/3~/2005 14:40, ~AX 831389774~ LSd_DEVELOPMENT Lydia A. To.ora, ChaJ~oman Ocxazd P. Go¢t~in§cr G~orgc Homing Ruth D. Oliva V~nccn". OrSa~do P;-.t~!cia C. Moore, Esq, 5! r~;!0 Main Road So~,~tnold, NY 11971 BOARD 01~ AI~I~LS TOWN O~ SOUTHOLD April 8, 2003 [~ 002/014 Son.old Town Hall 5309'; Main Road P.O. Box 1179 Soudmld, New York 11971-0959 ZBA Fax (631) ?65-9064 Tel~phou¢ (631) 765-1809 hnp://sourholdtown.aort hfork_nc£ Re: AppL No. 4942 - Breezy Sound CorP. (Special Exception) De~r Enclosed please find a c,opy of the Board's determination regarding the aboz,~. application. Please be sure to follow-up with ~ r,~lanning and Building Oepart~nents for the next step in the zoning reviews and application process. An extra copy of this dgterminatlon should be made aw~ilab;a to ~he Building Department at the time of ~s~.:bmi~.ing your maps and any other raqu~ed documentation to assist their offices next stops_ Vecf truly yours, of Decision to: Building Deped~nent Planrling I~,oard p8/3~/2005 14:,t0 FAX G313G9774G !.~M_OEVELOP~ENT March 20, ZOOS 4942 - Breezy ~ound Shores I000-4~-1-2.1 at Gre~lx)rt ) 004/014 In addiUon, the Boam has reviewecl ~e General ,Standards governing Special Exception uses set forth in Section 100-263 and finds that: A, That the use Will r~t prevent the orderly and reasonable use of adjacent prope~es or of pn~pe~es Lq adjacent use districts. B. That the use will not prevent the orderly and reas~nabls use of permllted or legally established uses in the district wherein the reqt~ested use is located or of permitted or legally established uses in adjacent usa districts. C. That the seres, the health, the welfare, bhe co~nfort, the convenience or the order of the town will not be adversely affected by the Resort Motel use and its location. D. That Ihe use will be in harmony with and promote the general purposes and intent of th;s chapter, E. That the use will be compatible with its surroundings and w~th the character of the ~ei~jhboCnoocl anti of [he community'in general, particularly with regard to visibility, scale ~,,;d <w~all appearance. F, '~,'~at sll proposed structures, equipment end material shall be readily accessible for fire a~.d police prolectlon. BOA:RD CONSIDERATIONS/REASONS: ~ln considering this application, and on the basis of testimOny Ixesented, materials submitted and personal inspecuons, the Board ha"- reviewed the code requirements set fotlh pursuant to Section 100-61B(4) and finds that the applicant complies with the Code requirements, and that 1. -i'ne proposed Resort Metal is required to be built on a minimum o1: five acres. Breezy Sound Shores Corp. has seven acres located on County Route 48. The · proposed project is bounded on the east by a motel and a ¢ondominfum. and on the west by a motel. The site is located across Eom the San Simeon Nursing Home on County Route 48, and to the no~th of the site ~s a bluff overlooking Long Island Sound. Breezy Sound Shores Corp. has received a Permit to build from the Town Trustees amended 1/7/02. The number of guest units is determined by the availability of water and sewer, When both are available, one unit per four thousand square t=ast is allowed. The applicant has pertnis'%n from ~e SUt~,11k County Water Authority to hook up to public water. Breezy Sound Shores Corp. also has obtained approval for s chromogless system from the SUffolk Cc~,unty Board of Health for sewer dial3osal or .08/3'0/2006 14:,~1 FAX B313587745 L'..:H_DEVELOPMENT Jan ~ O~ 72.~1~p ~o~e Law O~c~ Appl ~p. 4942 -- ;3J.'71~54G~3 005/014 they are in negoUations with the Village of Greenport f~ sewer hookup. This would allow construction of 68 units. ~'~o music, entertainment or loudspeaker ,Jystem shell be audible from beyond the prcperty line. 'The maximum size of a guest unit shal! be 600 square feel The applicants plans call f3r a living ama. kitchens{ts, and two bedlams all within the §00 square, feet limit. 5. ?he definition of a Resort Motel a;;~o includes the permission to build a manager's unit with one bedroom and kitch~,n, and a pool house, pool, office, and beech access. After considering ail tiaras under Section 100-6'; B(4), no evidence has been submitted to ,~how mat the safety, health, wafter6 convenienc~ order of the Town would be adversely ~affected by this P, esort Motel use. This project is subject to a site plan review by the ~'~hning R~.'-.':~ OLUTION OF THE BOARD: In cor:~idedng all of the above fac. tom al~d. applying the test under New York Town I.,3w ?..67-B, motion was offerecl by Member Olive, by Member To,ore, and ~luly ca~'i,~z;I, to GRANT Ihs applica~on for a Spemat ExcspUon, for a Resort Motel, subject lo the following Covenants and RestricUons, to be prepared by applicant in recordable form, approvmd by the Tmvn ,~.ttom~,y'e O~'!ice, and filed by the owner/applicant with ~e Suffolk County Clar,~:'s 1. Regardless ~f the form of (wv~.ership of the Resort Motel or the individual motel units, ~e re~ort motel will be operated in accordance wire the Southold Town COde. In accordance with the Southold Town Code, the Resort Motel shall be "rented on ~: daily rental basis or for vacationers or ~,[har persons on a weeldy rental basis." 2, A Management Company, or equivalent, shall be e~{abllshed which witi n~anage the day to day'operaaons of th .~ resort motel aha shall monitor mat the units are oK,~Feted as a resort motel. A Board of Managers, or equivalent, will establish the rules ar:c ff.;gulations of the complex. The ruies a~,.S regulatJol3s shall be in conforml~j w{th the S(~ul/lold Towl~ COde, ~ 3. The Operating Agreement of this complex ~tl provide that Individual owners of the resort metal units shall be guaranteed no tno~e than ~wo v~eek$ of occupancy thei~ unit during lhe prime seaso~. The units ere to be placed in a &v~dable to the public. In the event that-' thc' unit is not rented, the owner of the unit may 98/3'0/2005 14:4! FAX 631388??46 LSM_BE',/ELOPMENT · .'lan Page 4 - March 20, 2003 Ap~l. No. ¢~42 - Breezy $ourv" SlY, res 1CO0-45.1-?..1 at Greenpo~l ~]005/014 then occupy the unit in accordance with the rules and regulations established by the Board of Managers, 4. The Resort Motel w~ll be clo.-,ed from January 15u' through March 15~h of each year. The units shall not be occupied as a dwelling. 6. The Resort Motel unit shall be rented as a suite with two bedrooms, and the bedrooms may not be individually rented. ThL~ aclioe does not authorize or condone any c~.~'renl or future use, setback or other feature of the subject property that may violate the Zoning Code. other than such uses, setbacks and other leatures as are expressly addressed in this action. Vote of the Board: Ayes:. Members Tortora (Chairwoman), Goehdnger, Orlando, and ~3hva- (Absent' was: Member Homing or Fishers Isla~ld.) s Resolution was duly ,,,Iopted (4-0). Ly--dl~ A~o[rtora, Chairwomao ~-A~pProved for Filing P. HAP. LE-q M. THOMAS, I~.A. PE) Box 8~'7 ,IAMESPORT, NY 1 1 cJ4? September 19, 2007 Building Department Town of Southold 53905 Main Road P. O. Box 1179 Southold, New York 11971 Re: Cliffside Resort Condominiums Southold, New York 11971 (Building "C' permit # 31685) Framing Certification This letter shall serve to certify that we have inspected the 'as built' Framing in Building 'C' and have found that it is in conformance with the construction drawings & required standards. Please call the office with any questions or concerns at (631) 727-7993. Thank you. CHARLES M. THOMAS, R.A. PO Box 8'7'7 ,IAMESPORT, NY '1194'7 ~631) 7g 7-7993 March 19, 2007 Building Department Town of Southold 53905 Main Road P. O. Box 1179 Southold, New York 11971 Cliffside Resort Condominiums Southold, New York 11971 (Building "C' permit # 31685) Final Certification This letter shall serve to certify that I have inspected the above reverenced building and have found that it substantially conforms with the approved construction drawings & specifications. Please call the office with any questions or concerns at (631) 727-7993. Thank you. homas, R.A. CHARLES M. THOMAS, R.A. Po Box ~3'7~ ,JAMESPDRT, NY 1 '194'7 OFFIOg ('6~" ~ ] 727-7993 FAX [~3 1 ) 727-8033 March 1, 2007 Attn: Re: Town of Southold Building Department 53905 Main Road Southold, N.Y. 11971 Strapping Certification for Cliffside Resort (Building 'C' permit # 31685) 61475 Route 48 Greenport, NY 11944 This letter shall serve to certify that based upon my inspection of building 'C' on 12/09/06 the 'strapping' is in conformance with the construction drawings. Please call the office with any questions or concerns at (631) 727-7993. Thank You. ~, CHAI~LES M. THnMAS, P~.A. PO Box ,IAMESPORT, NY ~ ~ 94? June ~ 2007 B~lding Department Towmof Southold 53905 Main Road P. O. Box 1179 Southold, New York 11971 Re; Cliffside Resort Condominiums Southold, New York 11971 (Building 'C' permit # 31685) Flashing Detail This letter shall serve to certify that we have inspected the 'as built' revised flashing detail at the thru-wall girder connections in Building 'B' and have found that it was completed in conformance with the revised flashing detail. (Enclosed please find the manufacturers specifications and installations details) Please call the office with any questions or concerns at (631) 727-7993. Thank you. / Sincere C CHARLES M. THDMAS, P..A. PO Box 8~ ,IAMESPOF~T, NY ~ ] cj4~ (~531) March 19, 2007 Building Department Town of Southold 53905 Main Road P. O. Box 1179 Southold, New York 11971 Re: Cliffside Resort Condominiums Southold, NewYork 11971 (Building "C' permit # 31685) HVAC Installation Based upon site inspection of installed HVAC Units & Truss Manufacture's Engineers certification for Trusses supporting said loads, I certify the installation of the Truss Hung HVAC Units in Building 'C'. Please call the office with any questions or concerns at (631) 727-7993. Thank you. 'ely, Thomas, R.A. TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] ROUGH PLBG. [ ] INSULATION [ ]FRAMING / STRAPPING [ ] FINAL [ ]FIREPLACE & CHIMNEY [~IRE SAFETY INSPECTION [ ]FIRE RESISTANT CONSTRUCTION [ I FIRE RESISTANT PENETRATION DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FRAMING / STRAPPING [,,'~ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT ~NS'I~RUCTIO. N [ ] FIRE RESISTANT PENETRATION REMARKS: ~~ ~ DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. ~3C~z~<_~,,~~ 765-1802 INSPECTION UNDATION[ 1ST [ ] ROU?~H~LBG. [ ] FOUNDATION 2ND [/~rlNSULATION [ ]FRAMING / STRAPPING [ ] FINAL [ ]FIREPLACE & CHIMNEY [ ] FIRES~AEETY INSPECTION [ ]FIRE RESISTANT CONSTRUCTION [~]'I~IRE RESISTANT PENETRATION REMARKS: ~'/~/~"'-~'~ /'~ ~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]/~JGH PLBG. [ ] FOUNDATION 2ND [~'] INSULATION [ ]FRAMING / STRAPPING [ ]FINAL [ ]FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS:~--~~~ ~(~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] ROUGH PLBG. [~INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RF.,~ISTANT PENETRA'nON REMARKS: ~~///~,-~ ~'~ c~ TOWN OF SOUTHOLD BUILDING DEPT. 765-t802 INSPECTION [ ]FOUNDATION 1ST [ ]ROUGH PLBG. [ ].~JJ~A~ION 2ND []INSULATION ~~JSTRAPPING [ ]FINAL ~...~cE ~ c..,,.EY I 1 F.~ SAF.Y.SP~'T.0. REMARKS: ~ DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT/ION [ ] FOUNDATION 1ST [~ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] RRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ~/~--.~ ~/~-~-~./~ · _~/ DATE '~ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL ~ROUGH PLBG. [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PEk,- .-,ATION REMARKS: INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION REMARKS: [ ] ROUGH PLBG. [ ]INSULATION [ ]FINAL [ ]FIRE SAFETY INSPECTION [ ]RRE RESISTANT PENETRATION DATE INSPECTOR~~--~ Re: J606004RP The truss drawing(s) referenced below have been prepared by Robbins Engineering, Inc. under my direct supervision based on the parameters provided by Trianole Buildin9 Products. Pages or sheets covered by this seal: T2730705 thru T2730705 My license renewal date for the state of New York is June 30, 2008. October 16,2007 Albani, Thomas The seal on these drawings indicate acceptance of professional engineering responsibility solely for the tress components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-1995 Sec. 2. 6904 Parke East Boulevard Tampa, FL 33610-4115 Phone: 813-972-1135 ,Fax: 813-971-6117 www.mbbinseng.com DALLAS TAMPA FT. WORTH J60~6004RP A23-CR ~. sP ~4oooo s x- o- o o ~VAC 10-7-7 HO 6-6 HO 3-1-6 g TC ~ I 6-6-6 (,) W: 508 5x6: 5x~ 6 R:2250 SPL o U: 997 REPAIR PROBLEM: (t) Need to add 2 Point load(s) to the truss where shown(*). Points loads are from AJC unit. No repair required. ~ o October 16,2007 Quan T~pe Span P1-H1 Left OH Right OH I TR 260600 6 0 0 JOb ~a~k J60~OO4RP A20-CR HVAC R,tT 10-3-14 HO 6-6 REPAIR PROBLEM: (1) Need to add 2 Point load(s) to the truss where shown(*). Point loads are from AJC unit HO repair required. 6-6-6 I 11-8-3 5 9-11-8 26-6-0 HGR R:1849 U: 701 online Plus -- Version 21.0.060 RUN DAT~: 15-0CT-07 CSI -Size ..... L~ber .... TC 0.89 2x 4 SPF-2100 BC O. 93 2x 4 SPF-2100 -- 0.92 2x 4 SP-2400 F -E .......... To~ Chords .......... A -G 0.06 3111 C 0.07 0.79 ........ Bottom C~Ords ......... October 16,2007 j60~OO4rp A26-CR ~ a~ ~*osoo s ~- o- o o ~VAC ~'T 10-6-9 10-3-0 HO 6-6 6-6-6 REPAIR PROBLEM: (1) Need to add 2 Point load(s) to the truss where shown(*). ~ ~ Point loads are from A/C unit. No repair required. (*) 3x6 % A HO 6-6 47-6-0 N I S3 G 4x6 5x6- 4x8 9-11-8 [ 19-6-8 I 27-11-8 I 37-6-8 [- 47-6-0 W:508 October 16,2007 J60'6004RP~ BI2-CR = ~ 2~o=oo ~ l- o- o ~- o- o m/AC R/? 8-8 REPAIR PROBLEM: (1) Need to add 2 Point load(s) to the truss where shown(*). Point loads are from A/C unit. No repair required. 6-7-8 L 11-1-2 113-1-0 mss-l-0 { 7-4-7 7-0-14 HO 6-6 g 18-6-0 i 26-2-0 I~° 3x4 _ 3x6 -- 3x4 W:508 W:508 W:508 W:400 R:1092 R: 56 R:1706 R: 747 U: 543 U: 34 U: 739 U: 334 O~lino Plus -- Version 21.0.060 RUN DATE: 15-O~T-07 CSI -Size ..... Lumber .... Plus 6 Wind Load Case(S) Plus 2 U~balanced Load Cases M~mbr CS! P Lbs Axl-CSI-Bnd .......... Top Chords .......... I -F 0.94 1348 C 0.01 0.93 F -B 0.94 1018 C 0.01 0.93 B -G 0.72 234 T 0.00 0.72 G -C 0.72 615 C 0.00 0.72 ........ Bot~ C~ords ......... I -A 0.44 1211 T 0.27 0.17 A -E 0.63 1211 T 0.27 0.38 E -S1 0.62 454 T 0.10 0.52 S1-J 0.84 454 T 0.10 0.74 J -C 0.84 572 T 0.12 0.72 October 16,2007 j606004rp B20-CR ~ SP 2~0200 G 0 0 I'2730709 svac ~/? HO 5x6 =H 10-9-4 I 14-10-0 (*) 5x6 = B N HO 6-9-6 (*) F 6 U: 501 10-10-8 21-2-0 3J~L pLATES A~ C Robbins Engineering, Inc./online Plus~ APPROX. TRUSS WEIGHT: 150.8 LBS ......... Top Chord~ .......... 0.69 171B T 0.25 0.44 October 16,2007 J60'6004RP B21-CR z ~ ~xo2oo ~ o o HO 6-6 HO 6-9-6 REPAIR PROBLEM: ~] (*) ~(*) (1) Need to add 2 Point load(s) Point loads are from MC unit. No repair required, p o C~line Plus -- Version 21.0.060 RL~ DATE: 15-0CT-07 TC 1.00 2x 4 SP-2400 -- 0.67 2x 4 SPF-2100 -- 0.66 2x 4 SPF-92 B -K BC 0.99 2x 4 $PF-2109 .......... Top Chords .......... A -H 1.00 1943 C 0.01 0.99 ........ Bottom Chorals ......... ............. Webs ............. October 16,2007 J6I~6OO4RP B27-CR s aw.c ~¥ 10-1-3 9-9-10 HO 6-6 7x6 _ A § g g 7~ 34-7-0 C 40-10-2 L SPL HO 6-6 I 47-0-0 6x8 _ H S2 F E 3x6-- 3x8-- 4x8- 4X8-- S3 REPAIR PROBLEM: (t) Need to add 2 Point load(s) to the tress where shown(*). Point loads are from AJC unit. No repair required. 9-4-4 I 18-7-12 I 28-4-4 I 37-7-12 G 3x6 -- W;508 R:2689 U:1263 October 16,2007 J6I~6OO4RP B29-CR ~ sP saoeoo e o ~- o- o r273OTU HO 2-9-6 HO 6-6 ~ g ~ oo o U: 908 11-5-8 3x8 -- U: 937 21-0-12 I 27-5-0 I 33-8-0 REPAIR PROBLEM: (1) Need to add 2 Point load(a) to the truss where shown(*). Point loads33_e~0are from AJC unit No repa r requ red. [~ October 16,2007 ROBBINS ENG. GENERAL NOTES & SYMBOLS 108 PLATE LOCATION Center plates on joints in plate list or on drawing. Dimensions are given in inches {i.e. 1 1/2" or 1.5" ) or IN-16ths (i.e. 108) FLOOR TRUSS SPLICE ( 3)(2, 4X2, 6)(2 ) (W) = Wide Face Plate (N) = Narrow Face Plate LATERAL BRACING Designates the local/on for continuous lateral bracing (CLB) for support of individual truss members only. CLBs must be properly anchored or restrained to prevent sh~ultaneous buckling of adjacent PLATE SIZE AND ORIENTATION 3x5 I[ The first dimension is the width measured perpendicular in slots. The second dimension is the length measured parallel to slots. Plate orientation, shown next to plate size, indicates direction of slots in connector plates. DIMENSIONS All dimensions are shown in FT-IN-$X (i.e. 6'-8.5' or 6-08-08 ). Dimensions less in IN-$X only (i.e. 708). ~708 W = Actual Bearing Width (IN-SX) R - Reaction {lbs.) U = Uplift (lbs.) BEARING When trlls~ is designed to bear on multiple supports, interior bearing locations should be marked on the h-uss. Interior support or temporary shoring must be in place before l~usses are installed. If necessary, shim Metal connector plates shall be applied on both faces of truss at each joint. Center the plates, unless indicated otherwise. No loose knots or wane in plate contact area. Splice only where shown. Overall spans assume 4" bearing at each end, unless indicated otherwise. Cutting and fabrication shall be performed using equipment which produces snug-fitting joints and plates. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication and the attached truss designs are not applicable for use with fire retardant lumber and some preservative treatments. Nails specified on Truss Design Drawings refer to common wire nails, except as noted. The attached design drawings were prepared in accordance with" National Design Specifications for Wood Construction" (AF & PA ), "National Design Standard for Metal Plate Connected Wood Truss Construction" (ANSI/TPI 1), and HUD Design Criteria for Trussed Rafters. Robbins Eng. Co. bears no respons/bility for the erection of trusses, field bracing or permanent truss bracing. Refer to "Building Component Safety Information" {BCSI 1) as published by Truss Plate Institute, 218 North Lee Street, Suite 312, Alexandria, Virginia 22314. Persons erecting trusses are cautioned to seek professional advice concerning proper erection bracing to prevent toppling and" dominoing ,. Care should be taken to prevent damage during fabrication, storage, slxipping and erection. Top and bottom chords shall be adequately braced in the absence of sheathing or rigid ceiling, respectively. It is the responsibility of others to ascertain that design loads utilized on these draw/ngs meet or exceed the actual dead loads imposed by the sh-ucture and the live loads imposed by the local building code or historical climatic records. When truss hangers are specified on the Truss Design Drawing, they must be installed per manufacturer's details and specifications. FURNISH A COPY OF THE ATTACHED TRUSS DESIGN DRAWINGS TO ERECTION CONTRACTOR. IT IS THE RESPONSIBILITY OF THE BUILDING DESIGNER TO REVIEW THESE DRAWINGS AND VERIFY THAT DATA, INCLUDING DIMENSIONS & LOADS, CONFORM TO ARCHITECTURAL PLAN / SPECS AND THE TRUSS PLACEMENT DIAGRAM FURNISHED BY THE TRUSS MANUFACTURER. 6904 Parke East Blvd. Tampa, F1 33610-4115 Tel: 813-972-1135 Fax: 813-971-6117 www.robbinseng.com ~n;rD ~NS~'ECT~ON mn'O~T FO~DATION (1ST) FOUNDATION (2ND) PL~B~G ~SULATION PER N. Y. STATE ENERGY CODE . _ _ Fire Protection b~ Computer Design LTR FIRE DESIGN 108 MONTAUK HWY WESTHAMPTON NY 11977 631-288-7692 Job Name Building Location System Contract Data File CLIFFSIDE RESORT C SOUND AVE., GREENPORT, NY C 6-1-05_C.WX3 LTR FIRE DESIGN Page 1 CLIFFSIDE RESORT Date 063005 Hydraulic Design Information Sheet Name - CLIFFSIDE RESORT Location - SOUND AVE., GREENPORT, NY Building - C Contractor - LTR FIRE DESIGN Calculated By - CMR Construction: (X) Combustible ( ) Non-Combustible Occupancy - RESIDENTIAL Date - 062905 System No. - C Contract No. - Drawing No. - 10 Ceiling Height - 24'6 S (X) NFPA 13 (X) Lt. Haz. Ord. Haz. Gp. ( ) 1 ( ) Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure S Other T Specific Ruling Made By E M Are~ ~f~p~nk~e~ ~e~-~---i~ .... Density - 0.12 D Area Per Sprinkler - 130 E Elevation at Highest Outlet - 24'6 S Hose Allowance - Inside - 100 I Rack Sprinkler Allowance G Hose Allowance - Outside - 150 N Note 2 ( ) 3 ( ) Ex.Haz. Curve Date System Type Sprinkler/Nozzle (X) Wet Make VICTAULIC ( ) Dry Model VK27 ( ) Deluge Size 1/2" ( ) Preaction K-Factor 5.6K ( ) Other Temp. Rat.200 Calculation Summary Flow Required - 599.56 Press Required - 59.058 AT SOURCE C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 6-15-05 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 72 @ Press R Residual Press - 59 Elev. - -3 Well Flow - 2650 Proof Flow S Elevation - -3' U Location - NEAREST HYDRANT NORTH RD. Source of Information - LTR FIRE DESIGN C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M S R T A O U R K A G E ( ) Single Row ( ) Double Row ( ) Mult. Row Flue Spacing Conven. Pallet Slave Pallet Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Longitudinal Transverse Horizontal Barriers Provided: vvatul oupply t.,u,ve t~,) LTR FIRE DESIGN CLIFFSIDE RESORT Page 2 Date 063005 City Water Supply: C1 ~ Static Pressure : 72 PSI C2 - Residual Pressure: 59 PSI C2 - Residual Flow : 2650 GPM 150 D1 - Elevation : 11.910 PSI 140 D2 - System Flow : 599,56 GPM D2 - System Pressure : 59.058 PSI 130 Hose ( Adj City ) : __GPM Hose (Demand) : __GPM p 120 D3- System Demand : 599.56 GPM Safety Margin : 12.110 PSI R 110 E 100 S 90 S 80 C1 U 70 --~=---~~-- - ~~ 2 D2 R 60 E 50 / 40 3O 20 / 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW ( N ^ 1.85 ) C~3mt~uter Praaram,~ bv Hvdratec Inc Route 'ill Windh~m N H. USA 03087 Fittings Summary LTR FIRE DESIGN CLIFFSIDE RESORT Fitting Legend Abbrev. Name Page Date 3 063005 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Generic Alarm Va Generic Buttedly Valve Roll Groove Coupling Dry Pipe Valve 90' Standard Elbow 45' Elbow Gate Valve 45' Grvd-Vic Elbow 90' Grvd-Vic Elbow 90' Grvd-Vic Tee Detector Check Valve Long Turn Elbow Medium Turn Elbow PVC Standard Elbow PVC Tee Branch PVC 45' Elbow Flow Control Valve PVC Coupling/Run Tee Swing Check Valve 90' Flow thru Tee 45' Firelock Elbow 90' Firelock Elbow Wafer Check Valve 90' Fimlock Tee Mechanical Tee Flow Switch Fittings 'Summary LTR FIRE DESIGN CLIFFSIDE RESORT Unadjusted Fittings Table 1/2 3/4 Page 4 Date 063005 1 I 1/4 I 1/2 2 2 1/2 3 3 1/2 4 A 7.7 21.5 17.0 B 7.0 10.0 12.0 C 1,0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 9.5 17.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1~0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 1,0 1.0 1,0 1.0 2.0 H 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 I 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7,0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16,0 K 14.0 14.0 L 1.0 1.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11.0 12.0 13.0 O 3.0 3.0 5.0 6.0 8.0 10.0 12,0 15.0 P 1.0 1.0 1.0 2.0 2.0 2.0 3,0 4.0 Q 18.0 29.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 S 4.0 5.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 U 1.8 2.2 2.6 3.4 V 3,5 4,3 5.0 6.8 W 10.3 X 8.5 10.8 13.0 16.0 Y 2.0 4.0 5.0 6.0 &0 10.5 12.5 15.5 22.0 Z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 17,0 27.0 29.0 9.0 10.0 12.0 19.0 21.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 47.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 5,0 7.0 9.0 11.0 13,0 17.0 19.0 21.0 24,0 28.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 36.0 55.0 45.0 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 4Q0 10.0 12.0 16.0 19.0 22.0 33.0 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 4.2 5.0 5.0 8.5 10.0 13.0 13.1 31.8 35.8 27.4 21.0 25.0 33.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 P?essur~ / Flow Summary - STANDARD LTR FIRE DESIGN CLIFFSIDE RESORT Node Elevation K-Fact Pt Pn Flow No. Actual Actual Page D~e Density Area 5 063005 Press Req. S101 24.5 5.6 11.1 S102 24.5 5.6 12.54 S103 24,5 5.6 9,44 S104 24.5 5.6 8.95 S105 24.5 5.6 10.35 S106 24.5 5,6 10,42 S107 24,5 5.6 10.92 S108 24.5 5.6 11,28 S109 24.5 5.6 11.18 Sl10 24.5 5.6 8.41 Slll 24.5 5.6 7.96 S112 24,5 5.6 8.83 Sl13 24.5 5.6 8.97 Sl14 24.5 5.6 9.1 Sl15 24.5 5.6 8.78 Sl16 24.5 5.6 7.77 Sl17 24~5 5.6 8.32 Sl18 24.5 5.6 12.77 Sl19 24.5 5.6 9.62 S120 24.5 5.6 9.12 117 19.0 13.53 115 19.0 11.02 116 19.0 12,33 114 19.0 13.61 113 19.0 14.14 111 19.0 11.85 112 19.0 12.48 110 19,0 14.88 t09 19.0 14.34 105 19.0 12.03 106 19.0 12.86 107 19.0 16.27 108 19.0 18.19 102 19.0 10.97 103 19.0 11.72 104 19.0 14.78 99 19.0 12.21 100 19.0 13.06 101 19.0 16.52 90 19.0 11.36 91 19.0 12.19 92 19.0 14.76 93 19.0 14.85 94 19.0 15.15 95 19,0 t5.79 96 19.0 18.26 97 19.0 18.69 98 19.0 20.95 TOR 19.0 36.59 BOR -3.0 52.35 SRC -3.0 59.06 na 18.65 .1200 130.00 na 19.83 .1200 130.00 na 17.21 .1200 130.00 na 16.75 .1200 130.00 na 18.01 .1200 130.00 na 18.08 .1200 130.00 na 18.5 .1200 130.00 na 18.81 .1200 130.00 na 18.73 .1200 130.00 na 16.24 .1200 130.00 na 15.8 ,1200 130.00 na 16.64 .1200 130.00 na 16.77 .1200 130.00 na 16.89 .1200 130.00 na 16.59 .1200 130.00 na 15.61 .1200 130.00 na 16.16 .1200 130.00 na 20.01 .1200 130.00 na 17.37 ,1200 130.00 na 16.91 .1200 130.00 na na na na na na na na na na na na na na na na na na na na na na na na na na 250.0 na 7.770 7.770 7.770 7.770 7,770 7.770 7.770 7,770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 7.770 The maximum velocity is 20.57 and it occurs in the pipe between nodes 98 and TOR Final C~lculations - Standard LTR FiRE DESIGN CLIFFSiDE RESORT Hyd. Qa Dia. Ref. "C" Point Qt Pf/UL Fitting Pipe Pt Pt or Ftng's Pe Pv Eqv, Ln. Total Pf Pn Page Date 6 063005 Notes ****** S101 18.65 1.049 to 120 109 18.65 0.1144 1E 2.000 5.500 11.096 K Factor = 5.60 2.000 2.382 7.500 0.858 Vel = 6.923 0.0 18.65 S102 19.83 1.049 to 120 107 19,83 0.1281 0.0 19.83 14.336 K Factor= 4.93 1T 5.000 5.500 12.540 K Factor = 5.60 5.000 2.382 10.500 1,345 Vel = 7.361 16.267 K Factor = 4.92 S103 17.21 1.049 to 120 106 17.21 0.0986 0.0 17.21 1T 5.000 5.500 9.444 K Factor = 5.60 5.000 2.382 10.500 1.035 Vel = 6.389 12.861 K Factor= 4.80 S104 16.75 1.049 to 120 105 16.75 0.0937 1E 2.000 5.500 8.948 K Factor = 5,60 2.000 2.382 7.500 0.703 Vel = 6.218 0.0 16.75 S105 18.01 1.049 to 120 117 18.01 0.1072 12.033 K Factor = 4.83 0.0 18.01 S106 18.08 1.049 to 120 114 18.08 0.1080 1E 2.000 5.500 10.347 K Factor = 5.60 2.000 2.382 7,500 0.804 Vel= 6.686 IE 13.533 K Fac~r = 4.90 2.000 5.500 10.419 K Factor= 5.60 2.000 2.382 7.500 0.810 Vel= 6.712 0.0 18,08 S107 18,50 1.049 to 120 113 18.5 0,1127 0.0 18.50 S108 18.81 1.049 to 120 110 18.81 0.1162 0.0 18.81 S109 18.73 1.049 to 120 104 18.73 0.1152 0.0 18.73 S~10 16.24 ii049 to 120 103 16,24 0.0886 13.611 K Factor = 4.90 1E 2.000 5.500 10.917 K Factor = 5.60 2.000 2.382 7.500 0.845 Vel = 6.868 1T 5.000 14.144 K Factor= 4.92 5.500 11.281 5.000 2.382 10.500 1.220 K Factor = 5.60 Vel = 6.983 1T 14.883 k Factor = 4.88 5.000 5.500 11.183 K Factor = 5.60 5.000 2.382 10.500 1.210 Vel = 6.953 1T 5.000 14.775 5.500 8.406 5.000 2.382 10.500 0.930 K Fa(~tor = 4.87 K Factor = 5.60 Vet= 6.029 F'inal C~lculations - Standard LTR FIRE DESIGN CLIFFSIDE RESORT Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/UL Eqv. Ln. Total Pf Pn Page Date 7 063005 Notes ****** 0.0 16.24 11.718 K Factor = 4.74 S111 15.80 1.049 1E 2.000 5.500 7.961 K Factor = 5.60 to 120 2.000 2.382 102 15.8 0.0841 7.500 0.631 Vel = 5.865 0.0 15.80 10.974 K Factor = 4.77 Sl12 16.64 1.049 1T 5.000 5.500 8.833 K Factor= 5.60 to 120 5.000 2,382 91 16,64 0.0926 10.500 0.972 Vel = 6.177 0.0 16.64 12.187 K Factor = 4.77 S113 16.77 1.049 1T 5.000 5.500 8.966 K Factor = 5.60 to 120 5.000 2.382 116 16.77 0.0939 10.500 0.986 Vel = 6.225 0.0 16.77 12.334 K Factor = 4.78 S114 16.89 1.049 1T 5.000 5.500 9.099 K Factor = 5.60 to 120 5.000 2.382 112 16.89 0.0951 10.500 0.999 Vel = 6.270 _ 0.0 16.89 12.480 K Factor = 4.78 S115 16.59 1.049 1E 2.000 5.500 8.777 K Factor = 5.60 to 120 2.000 2.382 111 16.59 0.0921 7.500 0.691 Vel = 6.159 0.0 16.59 11.850 K Factor = 4.82 S116 15.61 1.049 1T 5.000 5.500 7.770 K Factor = 5.60 to 120 5.000 2.382 115 15.61 0.0823 10.500 0.864 Vel = 5.795 0.0 15.61 11.016 K Factor = 4.70 S117 16.16 1.049 1E 2.000 5.500 8.325 K Factor = 5.60 to 120 2.000 2.382 90 16.16 0,0877 7.500 0.658 Vel = 5.999 0.0 16.16 11.365 K Factor = 4.79 S118 20.01 1.049 1T 5.000 5.500 12.771 K Factor = 5.60 to 120 5.000 2,382 101 20.01 0.1303 10.500 1.368 Vel= 7.428 0.0 20.01 16.521 K Factor = 4.92 S119 17.37 1.049 1T 5.000 5.500 9.620 K Factor = 5,60 to 120 5.000 2.382 100 17.37 0.1003 10.500 1.053 Vel= 6.448 0.0 17.37 13.055 K Factor= 4.81 F(nal C~lculations - Standard LTR FIRE DESIGN CLIFFSIDE RESORT Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/UL Eqv. Ln. Total Pf Pn Page Date 8 063005 Notes ****** S120 16.91 1.049 IE 2.000 5.500 9.116 K Factor= 5.60 to 120 2.000 2.382 99 16.91 0.0953 7.500 0.715 Vel = 6.277 0.0 16.91 12.213 K Factor= 4.84 117 18.01 1.049 1T 5.000 6.460 13.533 to 120 5.000 0.0 92 18,01 0.1072 11.460 1.228 Vel = 6.686 0.0 18.01 14.781 K Factor = 4.69 115 15,61 1.049 1E 2,000 9,030 11.016 to 120 1T 5.000 7.000 0.0 116 15.61 0.0823 16.030 1.319 Vel = 5.795 116 16,77 1.049 1T 5,000 2,920 12.335 to 120 5.000 0.0 93 32.38 0.3173 7,920 2.513 Vel= 12.020 0.0 32,38 14.848 K Factor = 8.40 114 18.08 1.049 1T 5.000 6.460 13.611 to 120 5.000 0.0 93 18,08 0.1079 11.460 1.237 Vel = 6.712 0.0 18,08 14.848 K Factor= 4.69 113 18.50 1.049 1T 5.000 3.960 14.144 to 120 5,000 0.0 94 18.5 0.1126 8.960 1,009 Vel= 6.868 0.0 18.50 15,153 K Factor = 4.75 111 16.59 1,049 6.850 11.850 to 120 0.0 0.0 112 16.59 0.0921 6.850 0.631 112 16.89 1.049 1T 5.000 2.920 12.480 to 120 5.000 0.0 94 33.48 0.3375 7.920 2.673 Vel= 6.159 Vel= 12,429 0.0 33.48 15.153 110 18.81 1.049 1T 5.000 2.850 14.883 to 120 5.000 0.0 95 18.81 0.1162 7.850 0.912 K Fac~r = 8.60 Vel= 6.983 0.0 18.81 15.795 109 18.65 1.049 1T 5.000 7.750 14.336 to 120 5.000 0.0 95 18.65 0.1144 12.750 1.458 K Factor= 4.73 Vel = 6.923 0.0 18.65 15.794 K Factor = 4.69 105 16.75' 1.049 8.830 12.033 to 120 0.0 0.0 106 16.75 0,0938 8.830 0.828 Vel= 6.218 Final Ca'lculations - Standard LTR FIRE DESIGN CLIFFSIDE RESORT Hyd. Qa Dia, Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/UL Eqv, Ln. Total Pf Pn Page Date 9 063005 Notes ****** 106 17.21 1.049 9.830 12.860 to 120 0.0 0.0 107 33.96 0.3466 9.830 3.407 Vel = 12.607 107 19.83 1.049 1E 2.000 0.370 16.267 to 120 2.000 0,0 108 53.79 0.8114 2.370 1.923 Vel = 19.968 108 0.0 2.635 7.750 18.190 to 120 0.0 0.0 96 53.79 0.0092 7.750 0.071 Vel = 3.165 0.0 53.79 18.261 K Factor = 12.59 102 15~80 1.049 8.830 10.974 to 120 0.0 0.0 103 15.8 0.0841 8.830 0.743 Vel = 5.865 103 16,24 1.049 9.830 11,717 to 120 0,0 0.0 104 32.04 0.3112 9.830 3.059 Vel = 11.894 104 18.72 1.049 1T 5.000 0.370 14.775 to 120 5.000 0.0 97 50.76 0,7289 5.370 3.914 Vel = 18.843 0.0 50.76 18.689 K Factor = 11.74 99 16.91 1.049 8.830 12.213 to 120 0.0 0.0 100 16.91 0,0954 8.830 0.842 Vel = 6.277 100 17.37 1.049 9.830 13.055 to 120 0.0 0.0 101 34.28 0.3526 9,830 3.466 Vel = 12.726 101 20.01 t.049 1T 5.000 0,370 16.521 to 120 5.000 0.0 98 54.29 0.8255 5.370 4.433 Vel = 20.154 0.0 54,29 20,954 K Factor = 11.86 90 16.16 1.049 9.390 11.365 to 120 0.0 0.0 91 16.16 0.0878 9.390 0.824 Vel = 5.999 91 16.64 1,049 1T 5.000 2.920 12,188 to 120 5.000 0,0 92 32.8 0.3250 7.920 2.574 Vel = 12.176 92 18.01 2.635 10.390 14.762 to 120 0.0 0.0 93 50,81 0.0083 10.390 0.086 Vel = 2.989 93 50.46 2.635 10,390 14.848 to 120 0.0 0.0 94 101.27 0.0295 10.390 0.306 Vel = 5.958 94 51.98 2.635 10,100 15.154 to 120 0.0 0.0 95 153.25 0.0635 10.100 0.641 Vel = 9.016 Final Calculations - Standard LTR FIRE DESIGN CLIFFSIDE RESORT Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/UL Eqv. Ln. Total Pf Pn Page 10 Date 063005 ******* Notes ****** 95 37.47 2.635 1T 16.474 9.460 15,795 to 120 16.474 0.0 96 190.72 0.0951 25.934 2.466 Vel = 11.221 96 53.79 2.635 2.850 18,261 to 120 0.0 0.0 97 244.51 0.1505 2.850 0.429 Vel = 14.385 97 50.76 2.635 10.600 18,690 to 120 0,0 0.0 98 295.27 0.2135 10.600 2.263 Vel = 17.372 98 54.29 2.635 1T 16.474 37.120 20,953 to 120 16.474 0.0 TOR 349.56 0.2917 53.594 15.634 Vel = 20.566 TOR 0.0 4.26 6E 13.167 95.250 36.588 to 120 1Z 13.167 126.403 9.528 BOR 349.56 0,0281 1K 18.434 221.653 6.232 Vel = 7.869 IB 15.800 BOR 250.00 4.26 1E 19,896 10.000 52.348 K Factor = 250,00 to 150 1G 3.979 23.874 5.000 Fixed loss = 5 SRC 599.56 0.0505 33.874 1.710 Vet = 13.496 .0 599.56 59.058 K Factor = 78.02 PLANNING BOARD MEMBERS JERILYN B. WOODHOUSE Chair KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND August1,2008 Patricia Moore, Esq. 51020 Main Road Southold, N.Y. 11952 MAILING ADDRESS: P.O. Box 1179 Southold, NY 11971 OFFICE LOCATION: Town Hall Annex 54375 State Route 25 (cot. Main Rd. & Youngs Ave.) Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 RE: Site Plan for Breezy Sound, Greenport SCTM# 1000-045.00-01.00-002.000 Dear Ms. Moore: The Planning Board is in receipt of your letter requesting a final inspection dated May 28, 2008 for the above referenced application. As you requested, a site inspection was performed on June 9, 2008 and June 20, 2008, and we found that the site work was incomplete. At a third site visit on July 2, 2008, the Planning Board determined that the site was developed in accordance with the site plan approved on July 12, 2007. Please note that Planning Board approval is required pdor to any significant changes to the site. Please contact the Planning Department with any questions regarding the above matter. Kdsty Winser Senior Planner cc: Building Department Town Engineer q~ O" i~llOll UP T - II'-a" I1% lO'dO" 2"XlO" CC^ LEOSER 7 I· I ~ I/2" STANOAREP STEEL PIPE COLUMN ON A 54"X54"XIS"OEEP POUREID ._1 CELLAR F 7 CELLAR FIRE SEPARATION 7 UNIT MECHANICAL UNIT HOUSE CONNECTIONS qP~¥ ROO~ UnUT'~ ROO~ VENT EAN TTP. I ~ ~ ~" cc^ HE. _ J NOTE, EXIT I b~ ,7. F- I 2 ,,Xl O,,C CA~.x.. I IFAOP I I ~I~211 I F q CELLAR IHR. RATEO b F G CELLAR II II IL. UP I_ 2"XlO" CC^ LEOSE~os8 POURED CONCRETE FOOTINg, L I StEP FOUNDATIOR ~IALL FO TiNS TO MAINTAIN ~flN L_¢~a -Iq Y e MEONAHICAL UNI F HOUSE CONNECTIONS SEC STAIR~ CELLAR 4" POURED J CELLAR N T ON P q CELLAR 4" POURED UNIT UNIT (~x NOTE: LESEN~, L~AUNORY ROOh4 VENT RAN T'm. NOTE: F UNIT UNIT DESI®N SUBJECT TO DAHASE 125I-2" SEISMIC SI',,OH DESI®N LOAD HEATHER CRITERI PiPE ALARM C,ONTROL pANEL I~LA~P 5HO~/HEAT PE~CTO~ 4'5 F'G~ B ¢,EVEP~ HINTER ICE SHIELD FLOOD TERMINATE UNDERLAYHENT DECAY TEHP. REQUIRED ROOF UPLIFT LOAD HALL USE/ SHEATHIN® OCCUPANCY SUCTION LOAD OLASSIFIOATION HEIGHT FIRE AREA T'r'PE OF CONSTRUCTION (b FPI LONG ISLAND SOUND 52.90' -- ______ 54.04' --~ .- 50.22' -- --- 55.26' .... 57.85' -- 20.68'_ / / T/ONe .e *.o' S 24'02'49" W 297.94" ROAD CNORTH ROAD) (O.R. 48) -- --~ ~°- 175A Commerce Drive, Hau~auge, NY 11788 w~.bbvpc.~m PROPERTY SITUATE GREENPORT SUFFOLK COUNTY, N.Y. TOWN OF SOUTHOLD FOUNDATION LOCATION MIDDLE dUNE 23, 2006 1"-- 20' . I q -I- F-- -~,7~ -- [ iOL2,,, BEAPI - I I I I I/2" 5TANPARD STEEL PIPE ~,OLUMN ON A 54"X54"XIS"OEEP POUF-ED CONCRETE POORTINO 141TH --q ')g. TRUE'E5 t~ I~" OO. [ e L FI L MECHANICAL UNIT HOUSE CONNECTIONS C, ELLAP-. 4" PoUREr) CONC SLAB ~-Iq INSULATION I / L_ 5/8," SPIT, ROC, K ?FF. (I)-IIR. FIRE SEPARATION X LAUNPR~¢ ROOJ"I VENDING e (4,L!. ALI I'AHFIIION HAl 1_5 CEll AR 4" POUREM JFAC, P I N O T I%f:l OH (~RAOE ON VIHOjN_ ~OJL. I ~ I I I I q,.u,, I Q, FOb -dE, AbE; I/ N A -6GALE , N,rF.O. 5NON h CELLAR CELl A~ N 0 · ~: I--- I ALI- pARnTION T ON 5EISHI6 OESION PLAk NOTE, ] PER Joo~.2.11.2 (TI'P) FIRE ALAI;tI4 OONTI%OL PANEL HEAT OETEfcTOR SMOKE DETEGTOI~ NON-STRODE I~LAT5~ 5MO~/H~AT DETECTOR TO FERHINA I'E t4OPERA~ TO DECAY ¢JJ4iiHT TO HINTFR L6E 5HIEL.[2 FLOOD UNDERLAT'MENT YEHP. I-°E(~LJIRED I UP 3 I/2" 51'AN[~ARD SFEEI PIPE COl UNN ON A 541'X54 I'XIb"I>EEP POUREP GONGRE rE FOOR I I NO Mi I'l t I I I [- -, _j [ FOci~rIN~ I'O HAINIAIN MIN, 4~" I J 5~ SI CELl .AP-. k ' ROOF UPI IF I I.OAI) DESION GRITERI NAIl tJSE/ HEIOHr FiRE 'IYPE OF %1 il A II lING OCGIJPANCY AREA GONE1 RI JCl'ION 5UO I ION IOAP GL A5511=ICAI IOIq FPI 4) ,bi L' ?L ,¢ o" ~¢ BEOROOi','I BAT~ [ I~INO plVIN~ I=IVIN¢ ~ BE[P~O0~ plVIN~ ~oo~ ~ooM ~oo~ ~oo~ ~ ~ OLOS. ~ RAI'~D Fl~ 5EpA*A1 ION BED~OO~N ~ETE~TO~ ~--' DBTBO'I O~ g uP D K 2-2"xl2" HOP-. Boom E~AT_U.H P-..DV __STA L~ .... ~ S T A I R N 0 l- E AL~ STAIR RAILo NO F ~Z~ 1HAN . , . * PLAOA~O TO DE pROMIN~NIL'F plDPLATED AT EAOll BUll , - ~o~b / SlOE ) I ' <12 I IMR KII~IbN : IHR. ~TEP ~ A55EM~Y J BUILPlN¢ "omm 5Eld 5lTd PLI.AN¢ IHR ~g ~LL ASSEMBLY · l " /o~. i il L DXELLINe UNiT ~A J*bJ , ~ ,50LATEO CMOS/HEAT OETECTO~ ~' rJl~lEo Iold ..... -- ...... ~ IHR. ~P MALL A55EM~ J ,,® ® L poor, d / / / / / ~OOi'd / I SMOKF~/ N / 125 OFM _BATH D ~ I I¥1N©N PN pIVIN® ROOM SMOKE Q--DETECTOR OL~ b IVINO ROOI~ O ' GLO% BATIt CLOS L I-~1~ lp R04.) ~tG 5Tf~UCTUAL IdEFJBIzH ~AFI'E~S HA¥1N® SI-OF>RS ~<i£AH-I< ]IIAN?/12 ~. L_/180 S I All< NO YE; LEelEND: FIRE ALAFRM E,,ONTF~OL pANEL HEAT DETrEOTOR NON-STROBE ISOLATED;' SMoKF-/HEAT P~TI~GTOR E×I'ERIOR~ STROBE D K 2-2"xl2" I IDR I_IVIN® I~~ '11" 0 OLO% 6 EIPROOM 2-2'1×12" HIP~. J~ / / N / q~ f I uon I vi . ? /. IV_l N~ PN 5 CFM E I=, BA FI I f N q [. E~ j (2) HO UNII5 IN BUll DIN® B FOR A TO1 AL OF (4) UNITS 5EDROOl,d G ®- PN :1 ,aL DbO'lO / I /// G I / LIVIN® I,~ J P-.ooJ,,I I~ N ® AI.L 5FAIR ~4All b NO} LES5 THAN 34" $ NO I MOHE l llAN ~8" ALL EX'FERLO~ MALLS ~HALL INTERIOR FACE ONLY P~R UI 70z1,5 I=IRIE-RL:-SIB-I-ANCE RA IINO. ]Htz FIRE-RESISTANCE RAI-IN~ OF LcX'rERIOR ~ALLS MI I-II SNPARAIION DIO-I-ANO~ OF' ~¢EAIL_M IlIAN 5 F-EET 0524 BE RAI-ED I=OR EXPOSURE 70 PI~E F~O~ 5,565 SF LIVING SPACE SCAU,: ,/4" = ,'-o" ]ABLE 160~,1 OF TI SIIL[:I A ..0. _ __ ~EQUI~E~ENI-5 I0" x q'-o" HOURED GONGRE'NE b- · [-I PLU~H --I -- I -- I I= I--- L_ I I I I I I I '~ I I 3- 2"xlo"_c_c& HDR__ J I J 54 "X54"X15 DEEP POURED I~ z~ bib" 51iT, NOOK, IYI= CONGRETE,~OORTINO. PqlTH ' ~ H ~ (IF~l'l~ lUmP ~ ~ 5/~" 51ql'. ~04, K TYP, N 0 T ~: I L t~UNI')I<Y = To I ' I ~d~P II , I ,..4.. I ~ ~_ e-~" ---~ I FIRE 5EPAb4.A/ION I ~ VENDINO AUNDF~T I~.0 C~N , [ ' [I I-' ~ "f -- - 1- ~ I=OOTINO HI Iii (3) it 4 DARE, L-ACllI HA'F fDOT7OM) "lin 4~" 13ELOHL 3 ?"X..IC)']oC'_A JJER. .J LDCEND, FAOP] PIRt~ ALARM OONTF~OL PANEL HEAT ,SMOKE DETEGTO~ I~OLA~D ~MOKE~T PETEOTOR A I/4" = ILO' DESION OR TERIA SROUNE HIND SEISMIC SUBJECT TO DAMA®E Hli~IER IOE SHIELD FLOOD [ [IVEDEALS ROOF UPLII=I lOAD biAl[ USE/ HEISHT FIRE ITPE OF 5NOM SPEED DESION PROP FROST DEGiOI'UNDERLAYNENT HAZARDE IOAC I OAI5 5NItAIIIINO OCOUHANCY AREA CONSFRtJOIION LOAD (HPII)GAFE~R' LINE 4fAI'blRRINO DFPI'IIrRRHINAFE DECAY l~lqP. REQUIRED GUOI'ION LOAD CLA551FICAFION }lq~;l ~4' 40" G [5A3 ii LIVINL5 P~OOivf IHIa. RATED MALL ASSEMBLY ~NO, U DO6 BNPl,.4OOhfl !¢ATH U) h~ L[VIN_~ bLOOIvl lIE. RA'I EI~-~AI..L ASR11M[3I [' b p[VIN(& ROOlvl BA Fl l ilL GSA D~-OK LIVING ROONI X = OLDS RAI E~ FiRE SEPARA FION ~ATED G ~) G FII:~E S~PARATION IIll~L I~ATEU btALL , ~ B~3PROOM ,,~ ® ® 4X4 CCA F I R?FT F L O O P-. P L A N t;l-Ail~ NOIP: N_O_!'=, 4,128 LIx,,/IN® SPACE .All S JAil'S P~R IO~;~.~l:'l ~ · [.DCA FIE FIP. E EXTINeSUI~I~P. PlZl~ N.Y. ST^YE COB)t; ]~RAE)5 NO1 Itq~5 IHAN IP L-~ O O ~ S G II ~ D U I. 17 SCALE: i/4"= r-ot~ ~ MISI-RO NOF 10 EXC,i bi9 7" i GRNIRALpER N.T, 51'A'rbSIAl'IONcoPESMO~E I IlEAl DErbonoN (L:OOP` HANUI=AG1URL-D PER SILVER LININ~ SERIES 5500 VINYl SLiDIN~ &LASS PA FiD) 14 I N E) O H SC H E ~U L E 'ALL ~IINO01,'IS 1'4ANUFAG FURED pEP- SILVER LININg' 5¢P-IES IOOO VINYL DOUBLE HLJFIO) -- P. OU®H oPENIN~ COPIh4ENTS/ GOLOP- ! I,dOPEL B4 Itdl' X 65 1/4" 20 I/4I' X 65 i/4" HI-lITE TYPIC, AL PLUMDIN® RISER ~GALE: N.T.5 DIASRAI'4 N O T E: ALL EXTERIOR P~IAI_[ 5 SliAI I BE INI ERIOF,,t FACE ON[ Y I;E~ UL IHR. PIF~E RAIiEI?II<OH I IlL 265. -IO4.b f-IRk F<EBIS'IANOR I-4AI lNG. I'HE F;I~F: RIZSISI-ANGI RAFING OF IEXTEF,,tlOR ./,IALI 5 k,lllll A SEF~ARAI ION DISIANGb. OF GF-.tEATER THAN 5 Fl-El (15224 'Hi'd) OItALL BE P. ATEi9 I BE L-XPOBUF,,tL; 10 I=lF,,tE FRO]vi l lll-E IN_CSIL)L-. 17 r~UAN'FITT fir 50, I IRE DOOR ( B LABEL ) 45 MIN. 5,0. FIRE DOOR ( C LABEL ) LEGEND, FIRE ALARH GONTF2,OL PANEL HEAT lPBTEGTOR SMOKE I~ET'EOTO P` NON-STP-ORE I~PLATt~P 51qOKE/HEAT DETECTOR EXTEP-IOR STt~DBE FAOP [ (5) © A] I~ L x,N I ]VIN~ P. OOM \ \ \ F~ E D LJV_IN~ F. OOlv (2) L_WIN® ROOM SEE P--OOk' '[~4L)~S I:I~.ANINd PI-AN BY OTIIE~S DEC, K , DN [.IVl NO ~OON/ ALLOHABLE OEI~LEC'FION L/180 I 1/180 X, [3~A_[j i IH_ I /5~0 L/24O L/240 L/12O ¥~1..<(__ . - Al I OHAIJI-f: DEPI.bGTION OF ii'Il ]qlt ~1-'. BIAII ~.~ AND ?AI~a IGIAIqb 'E~I[ 14]()1~ /4ALI S k!lND I.OAD~: IdlTit Plq j ,o,.s,,J t b s,, B~DROO~q STAI ~, NOTE: SEC, ONE) %LOOP PLAN 4,128 SF LIVING ,SPACE SOALE~ I/4" = I'-O" PAd, P ] ® · HANDP-AIL5 PER [OO3,D D II ALL STAI~ RAIL5 NOT LES5 FHAN 34" ~r NOT ~iORE THAN 141 HOP. N L~ 0 P,I 5, O I[ E D U ] 15 'ALI 141NIDO~I5 NANUI:AGILJF4.EL~ ~Et~ 51LVEI-E LININ~ $ERIE5 I000 VINT'L DOUBLE HUNO) 20 I/4" x 6D I/4" QUANTITY SYMBOL E) O O R S O iq E iD U ] I~ (DOOI-~ HAhqUFAC. IUIP`ED ?EI~ 5[LX/I~P, L INIIq~ Slc[41EG D:~OO VINY'L ~LIDiN® ~LAS~ PATIO) ROUGtl OPENING 72 I/D" x 8,0 I/4" QUAN FITY I~ iIR 56 FIRE POOR ( B I ABEL ) 4b HIN. 5.6 FIRE DOOP, ( 6 LABEL ) SYMBOL NOMINAl 51ZE ~) S/O x~5/D (~ 3/o x II/O D~) 3/0 x ~/o I,~O FIR~F FLR, LEFT SIPE ELEVATION O F R O N .,T, E L E V A T I O N SCALE: 1/4" = luO" ' SCALE: 1/4" = lUO P-.I®HT SIDE ELEVATION SGALE~ I/4" = I'-O" LEe~ENP, O F lEST FL COP-. PLA BE, ALE, I/,4" = ® ® REMOTE ANNUNC,,IATORS HEAT DETECTOt~- SMOK. E OETECTOR NON-STROBE ISOLATED Sh'IO~E/HEAT DETECTOR EXTERIOR STROBE N REAP--.,, ELEVATItON SCALE: I/4" = I'-O E®ENE): P-.EMOTE ANNUNC, 1ATORS HEAT IPETEOTOP-. SMOKE B)ETECTOR NON-STROBE ISOLATEE) SMOKE/HEAT EXTEP-..IOR STROBE PETE©TOR 48'-0" FOUNI:?ATION PLAN SCALE, I/4" = I'-0" T'r'PIOAL oEILINc, oONSq F4.tJ(]. IlON /. I'TI:fl_(eAJ I~00[: (.4PNo-I RUG I ION \ OFFICE LIVIN¢/ pINING ROOM NYS CODE (1'¥P) OEI fAR. T"'?ICAL FI 00~. OON:~ FP. UOTI ON_ CROSS SECTION SCALE, I/4" = I'-0"