Loading...
HomeMy WebLinkAbout33581-ZFORM NO · 4 TOWN OF SOUTHOLD BUILDING DEP~RTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33478 I~]te: 01/08/09 11{IS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 3895 DELMAR DR LJkUREL (HOUSE NO.) (STREET) (HAMLET) Co%k~ty Tax ~lp NO. 473889 Section 125 Block 4 Lot 2 subdivision Filed Map No. __ Lot No. __ conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 1, 2006 pursuant to which Building Permit No. 33581-Z dated DECEMBER 13, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS AND ADDITIONS, INCLUDING DECK, TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. · ~ne certificate is issued to ALBERT C NAEKEL III (OWNER) of the aforesaid building. SUF~LKC~3~I~fDEPAR~TOF ~L~"~PRO~-AL N/A ELEt-rKICRkL CI~RTIFIC~TE NO. 123545C 09/19/08 pL~ER~ CERTIFICATION DA'r~3 12/23/08 CLASSIC PLUMBING & HEAT uthori~ Rev. 1/81 This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworu statement from phimber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Location of Property: House No. Owner or Ownem of Property: Suffolk County Tax Map No 1000, Section Date. Old or Pre-existing Building: b/ (check one) Street Hamlet Block ]Z-fi'. -~'/~ Z Lot Subdivision Fe,mNo. Date of Permit. Filed Map. Lot: Applicant: /jr O~-e~' C.- Health Dept. Approval: Underwritem Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ Final Certificate: V/'" (check one) Applicant Signature Issue Date 9/19/2008 Electrical Inspection Certificate Electrical Inspection Service, Inc. Application Number 375 Dunton Avenue 123545C East Patchogue, NewYork 11772 (631) 286-6642 Issued To: Mr. Albert C. Naekel III Street: 3895 Delmar Drive Village: Laurel Zip: 11948 Section: 125 Block: 0004 Lot: 0002 Contractor: Three Brothers Electric Inc. Town: Southold Lic,# 3792-E Was examined and found to be in compliance with the National Electrical Code. Commercial [:~ NVDefects ! Pool i-X] lstFIoor IX Indoor [Xl Basement i i HotTub Residential ~!J Det. Garage ~1 Attic ~ ~] 2nd Floor iX Outdoor ~ Addition ill Survey Switches Receptacles Fixtures GFI Heaters AJC Fans 39 54 51 4 2 3 Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwaves 1/20a 1 20 1 30 2/20a 1 Gas 1/20a Furnace Oil Gas Circulators Smoke Detector Bell Transformer I x 3 5 1 Meter Amps Phase UG/OH Jacuzzi Television CO Detector Bldg. Permit: 33581Z Other Equipment ~_-30 ~mp A/C ~isc./1,~ra~e Door opener Recept. Hugo S. Surdi President 06/11/2008 John Mc Mahon III This cedificete must not be altered in any manner. Inspectors may be identified by their credentials. Town I Tall Anncx s4375 Main Road PO. Box 1179 Saulhold. New York 11971 0959 ][3 UILDING DEPARTMENT TOWN OF SOUTHOLD CERIIFICATION (Please print) Icad. I cmtlfy that thc soldel uscd U', the water supply system contam~ less than 2110 (Plumbers Signaturm FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33581 Z Date DECEMBER 13, 2007 Permission is hereby granted to: ALBERT C III NAEKEL 3895 DELMAR DRIVE LAUREL,NY 11948 for : ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. at premises located at County Tax Map No. 473889 Section 125 pursuant to application dated NOVEMBER Building Inspector to expire On JUNE 3895 DELMAR DR LAUREL Block 0004 Lot No. 002 1, 2006 and approved by the 13, 2009. Fee $ 423.60 ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765- t 802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING [ ~'FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION REMARKS: [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION DATE Io~2-~ -D ~ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ] ROUGH PLBG. [ ] INSULATION [~INAL ] FIREPLACE & CHIMNEY ] FIRE RESISTANT CONSTRUCTION REMARKS: [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION DATE / ~ ~/''~'~ ~ ~ INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INACTION [~J~INAL [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]RRE RF. SI~_ CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARK~I~'~-~ ~ .~ DATE ~~--- INSPECTOR ~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]~ PLBG. [ ] FOUNDATION 2ND [~'~ INSULATION [ ]FRAMING/STRAPPING [-]FINAL [ ]FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION [ ]FIRE RESISTANT CONSTRUCTION [ ]FIRE RESISTANT PENETRATION REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION I~/~ FIRE RESISTANT PENETRATION [ REMARKS: DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-t 802 INSPECTION [ ]FOUNDATION 1ST ~~. [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION REMARKS: [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] F~ION 2ND [ ] INSULATION ~*/~~TRAPPING [ ]FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] F~UNDATION 2ND [ ] INSULATION [v~'FRAMING S~RAPPING x--,~ [ ]FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION DATE ~/~/'~//0 ~ INSPECTOR ~~ 335~/.7~ ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST ~FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ]INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: ,. DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ROUGH PLBG. ~-'~FOUNDATION 1ST [ ] FOUNDATION 2ND [ ]INSULATION ]FINAL / ]FIRE SAFETY INSPECTION [ ] FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: m£o ~s~,scrio~ m, oa~ I ~ ~ co~s PLL~G ~ ~Zad ~ ~' i ~ STATE ENERGY CODE ~DITION~ CO~ENTS ~ TO%VN OF SOUTHOLD BUILDING DEPAR~Ti~IENT TO%VN HALL SOUTHOLD, NY 11971 TEL: ~63t) 76~i802 FAX: (631) 76~9502 x~-. n orthfork.nel/Soulhobt; BUILDING PEYGMIT APPLICATION CHECKLIST D:, yo.* have ,.,r n~ed th~ folh, a,.mg. ;,~for. applTin~" ~oard ,,f ~Ath Cantact: APPLiCATiON FOR BUILDING PERMIT Date INSTRUCIIONS a. ~ltis application MUST be completely filled in by ~-pewriter or in ixtk m~d subnfitted to the B~l&ng ~speetor ;;4th 3 sets of plus, aecm'ate ph, t plm~ to scfle. Fee aecor~ng to sehed~e. b. Plot pi~ sho;~ng locati~ of lot ~d of btfil~ngs on pre~ses, relations}tip to adjoimng prcnfiscs or public ~n'eets or e ~e w~,-k- covered by tbJs ~pp!i~fio~ m~y p,~t be eo~mcm:*l bcf, x'c issumcc ofBuildh~ Pcmfit. d. Upon approv~ offs applicafi~, the Buil(hng h~spcctor will issue a B~l~ng Pe~t to the applicmm Such a pem~t sh~l be kept m thc pre'scs av~lable k.r inspection fln'oughout thc work c. No buil~t~ shMl be occupied or used in whale or in p~ ~br m~y pnpose what so cvcr until the Bt~lding h~spcctor issues a Ce~fieate of Occupm~cy. f. Ex.~ bnih~g p~ufii sh~l ~pi[e if the work au~mfized has nO conancnced wi~fin 12 mon~ts ariel rite dale of issum~ee or has not been convicted ;~4tlfin 18 ~nonths fi~om such date. If no z~ng mnen~cnts or other reaOafions afi~c~a the addition six mont~. ~erea~er, a new pm~fit shMl bc req~md. APPLICA~ON IS ~BY N~DE to the Buili~ng Depm~mct~ ~br the issumee ora Btfilding Pemfit pt~su~t to the Btfildi~ Zone Or~tm~ee of the Town of Southold, Suffolk Com~,, N~' York, md off,er applicable Laws, Ordinmces Re~ulatlons. for the constt a~fion ofbGl~ngs, ad~fions, or ~teratim~s or t%r mmov~ or dcmoiifion as herein described. ~le applicm~ a~rees to eoraply with Mi applicable laws, ordinm~ccs, b~ng code, Bottling code, mid rcg~lation~, (/ignamre ,vf appiicomt ~,r nmne, if a co~oration) (~{~dlir, g ad& ess of a~,plicant) State whether applicant is owner, lessee, agca~t, architect, engineer, ~neral contractor, electrician, plnmber or builder Name of owner of premises gL~ff'~'7~ C /V~J~rJ~'&'~ /~ (As on the tax roll or late.~ deed) If applicant is a coq)oration, si ~mmture of duly authorized officer (Nanm and title of corporate officer) Builders License No. Plumbers License No. Electiidmis License No. Other Trade's License No. I. Location of lead on which proposed work will be clone: 37q ' P,ezm ,e vd House N mnber S~'eet Com~E~, Tax Map No. 1000 Section Subdivision d~ (N Hamlet Filed Map No. Lot . ff 2. State existinr, use and occupancy' of premises and itRended use aid occupant' of proposed coustmcfion: Existing use vad occupang' b. intended use sad occupan%' 3. Nature oi wak (check which applicable): New Building. Adchtion Repair Removal D em olili on Oth et' Vqork Estimated Cost ,~,tggg/ ~flboe2, ~ 5. If dwelling, number of dwelling uats If g~mge, number of c~rs Fee Alteration (D escripti mil iTo be pa~d on iliag th~s applicatioa~ Number of dwelling units on each floor / 6. d business, commercial or mixed occupancy~ speci~, nata'e and extent of each tv~)e of use. 7. Dima~sions of exd~ing strnctures, if any: Front ~tt'~* Rear ~/(-/~? Depth ,~'~ Height /~ t Number of Stories / Dimensions of same structure with alterations or ~dditions: Front ~(, ~fir~ Rear Depth ,.¢"~> ' 0 * Height. /~' Number of Stories 8. Din, ensions ofentkenew consti'uction: Front Ct/¢ ~'~* Rear ~J2'/0' Depth Height /~, ~ Number of Stories / 9. Size of lot: Front /519' Rear /,~t~ ' Depth /~flO ' 10. Date of Purchase ,~ghCO Name ofla:onner Owner ,~8~/r'&? /~/J/~'/t'¢/. i i. Zone o~ use district in which pt~mises ae situated 13. Will, ~, 14. Names of Name of Architect~ Name of Contractor Ad(kess Phone No. 15 a. Is this propem/within 100 feet of a tidal wetland or a fi'eshwater wetlaud? *YES NO /~ ' zF '5 ~ S, oOb 2XtOLD TO¥~ N TP, E, STEE S & D.E.k_ PEPd~ii z ~ M~'k BE RE QUI~ED. b. ls fins properS; within 300 feet of a tidal we~ianfl? ~ ~'~S, ~, NO * IF YES, D.E.C. PERMITS MAY BE REQUESTED. 16. Prov.de .mve¥, to .~ca.e, wt/n accurate foundation plan and distances to properPy lines. 17. Ii elevation at any pant on properS- is at 10 ted or bdow, mub{ provide topographical data on atrvey. S TA TE OF NEW ¥OKKi SS: CO[%T7 OF } ~_£ ~-Z[ e ~ ~ bein~ d~y s,vom~ deposes m~d says flint (s)he is the applic=t (Nm~e ofin~x~du~ sigMng con. act) above n~xed, (Contractor, Agent, Corporate Officer, etc.) of said owner ,.,r owners, m~d is (My autht~'ized to pert'om~ or have peffmned the said work m~d to m&e md file thts application; that all statements contained in tiffs application m'e tt-ac to the best of his knowledge mid belief; and that the work will be performed in 6~e rammer set font~ m fnc apptieai on fikd tim ewitk Notaty'¢'~SblieTM Signat~ n'e of Applicant Public, State of Ne~Yoi'~ No, 02ST5027579 Oualified in Suffolk Cou.t~., ~mlnlis~ion Expires May 9, gOD'?'. HOME. IMF)ROVEM~NT CONTRACTOR LICENSE KENNETH M MOSKELAND 43738-H 7 r~v,~,~ ~ tl/~1/2009 Norseman Building Corp. 444 West Jericho Turnpike Huntington, NY 11743 tele: (631) 692-5050 fax: (631)692-5904 November 8, 2007 Mr. James Richter Southold Town Hall P.O. Box 1179 Southold, NY 11971-1179 Dear Mr. Richter, This note is to remind & restate what we discussed in our conversation on November 2, 2007 pertaining to question #7 on the attached form. The existing driveway is to remain as is a~d is not included as part of this project. Very truly yours, NORSEMAN BUILDING CORP. Kenneth Moskeland Vice President Town -of Southold ~ L.~' ~Eroslon, Sedimentation ~ A85E88MENT FOR~ ~;'~ ?ROPERI~ LOCA~.TIOH: 8.C.T.M.~: THE FOLLOWING A~ION8 ~y REQUIRE ~E 8'""~""q" OF · " ~ ~C~ ~ 'c~ 8TOR~WATER G~DING D~I~OEAHD ~081~N'; '~ ....... ~ ' Illem Number: 1 2 3 4 8 9 (NOTE: A Check Mark (~) for each Question Is Required lot a Complete Application) Yes No Will Ihle ProJeot Retain All SIorm-Water Run-Off Genereled by a Two (2") Inch R~lnfell on Site? (This Ilem will include all mn-off creeled by site cleadng and/or conslmctlpn ectlvllles as well as all Sile Improvement~ end the permanent creation of impervious surfaces.) Does the $lle Plan end/or Survey Show Ail Proposed DreJnage Slmctures IndlcaUng Size & Location? Tiffs Ilem cheil Include ell Proposed Grade Changee and Slopes Conirolling Surface WaterFIowl Will thle. PiloJecI Require any Land Filling, Grading or Excavetlco where there Is a change to the Natural Exleling Grade Involving more Ihan 200 Cubic Yards of Matedal Wflhln any Parcel? Will this/lkopgcadon Require Land Dlslurblng Acllvltles Encompassing en Area In Excess of Five Thousand (5,000) Square Feet o! Ground Surface? Is them a Natural Water Course Runn ng through the Site? Is this Project within Ihe Troslees Judsdiclion or within One Hundred (100') feel of a Wetland or Beach? Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vedical Rise Io One Hundred (100') of Horizonlal Distanc. e? Will Driveways, Perking Areas or other Impe~,ious Surfaces be Sloped to Direct Storm-Water Run-Off into and/or In the direction o! a Town rlght-ol'-way? Will Ihte Project Require [he Placement of Material, Removal of Vegelation and/or the ConsImction of any Item Within Ihe Town Righl-oI-Way or Road Shou der Area? (This Ilem wlH NOT Include the Installation of Driveway Aprons.) Will this ProJecl Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercourse? NOTE: IlAny Answer to Questions One Ihrough Nlnb Is Answered with e Check Mark In the Box, e Storm-Water, Grading, Drainage & Erosion Control Plan Is Required end Must be Submitted for Review Prior to Issuance of Any Building Permlll EXEMPTION: ~ : Yes No Does this project meet the minimum slandards for classilicaiton as an Agricultural Project? / Note: If You Answered Yes to this Question, a Storm-Water, Grading, Drainage & Erosion Control Plan I$ NOT Requlredl __ ,~ STATE OF NEI~ YORK, cou~rr~ ox .................................. /. ....... ~.~, ~~ c · '~ /~ ~. ' ...................................... · ~ ......... ~. ............. bcmg dui) sworn, d~poscs m~d s~ys d~a~ h~shc ~s d~ applicant [~r Pcrm~ O~n~r ~or repr~en~ve o[ dm Owner o[ 0~ net s, mul ~s duly authorized to perlbnn or have perlbrmed Ihe ~d work and to m~e md file fld~ application; O~at ~1 ~temen~ tongued m ods appli~on a~e ~e Io O~e best of his B~o~vle{lge and beliefi · at ~e ~rk ~1 ~ performed in fl~e m~mer' set [ortb in O~e application filed herewid~. Sworn ta ~fore me dti~; FORM -06~07 ~o"~ REScheck Software Version 4.1.0 Compliance Certificate Project Title: 07.136 Report Date: 10/24/07 Data filename: F:\MEC AND RES CHK PROJECTS\07 Projects\07.136 NAEKEL rck Energy Code: Location: Construction Type: Heating Type: Non-Electric Glazing Area Percentage: '14% Heating Degree Days: 5750 Construction Site: New York State Energy Conservation Construction Code Suffolk County, New York Detached I or 2 Family Owner/Agent: ALBERT NAEKEL 3895 DELMAR DRIVE LAUREL, NY 11948 Designer/Contractor: GARY D. CANNELLA ASSOCIATES 55 KNICKERBOCKER AVENUE BOHEMIA, NY 11716 Maximum UA: 470 Your Home UA: 470 = 0.0% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Ceiling 3: Cathedral Ceiling (no attic) Wall 1; Wood Frame, 16" oc. Window 1: Vinyl Frame:Double Pane with Low-E Door 1: Solid Door 2: Glass Floor 1: AIbWood Joist/Truss:Over Unconditioned Space 2007 30.0 0.0 70 194 19.0 0.0 10 138 15.0 0.0 9 2244 13.0 0.0 154 232 0.330 77 37 0.300 11 93 0,310 29 2339 19.0 0.0 110 The proposed building represented in this document is ( with this permit application. The proposed systems Code requirements. When a Registered Des his/her knowledge, belief, and professional Name - Title 07.136 Page I of I REScheck Software Version 4.1.0 Inspection Checklist Date: 10/23/07 Ceilings: ~1 Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [] Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above-Grade Walls: Wall 1: Wood Frame, 16" c.c., R-13.O cavity insulation Comments: Windows: Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Comments: Yes No Doors: Door 1: Solid, U-factor: 0.300 Comments: [] Door 2: Glass, U-factor: 0,310 Comments: Floors: [] Floor 1: Ali-Wood JoisCrruss:Over Unconditioned Space, R-190 cavity insulation Comments: Air Leakage: [] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. [] Recessed lights are 1) Type lC rated, or 2) installed inside an appropriate air-fight assembly with a 0.5" clearance from combustible materials, If non-lC rated, fixtures are installed with a 3" clearance from insulation. Vapor Retarder: r~ Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [] Materials and equipment are installed in accordance with the manufacturer's installation instructions, Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ¢-I insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. [] insulation is installed according to manufacturer's instructions, in substantial contact with the sur[ace being insulated, and in a manner that achieves the rated R-value without compressing the insulation, Duct Insulation: Supply ducts in unconditioned attics or outside the building are insulated to R-8. Return ducts in unconditioned attics or outside the building are insulated to R-4. Supply ducts in unconditioned spaces are insulated to R-8 07.136 Page 2 of 4 Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: n All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), masfic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. wg (500 Pa). ~1 The HVAC system provides a means for balancing air and water systems Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit Fireplaces: [-~ Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and out,et unless the water heater has an integral heat trap or is part of a circulaling system [~1 Circulating hot water pipes are insulated to the levels in Table 1 Circulating Hot Water Systems: [~] Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: F~I HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. 07136 Page 3 of 4 Tab/e 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1 25" 1 5" to 2.0" Over 2" Temperature (°F) 170-180 05 1 0 1.5 2.0 140-169 0.5 0.5 10 1.5 100-139 0.5 05 05 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp Piping System Types Range(OF) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1 0 LOW Temperature 120-200 05 Steam Condensate (for feed water) Any 1 Cooling Systems Chilled Water, Refrigerant and 40-55 0,5 Brine Below 40 1.0 1.5 1.5 20 1.0 1.0 1.5 1.0 1.5 2,0 0.5 075 1,0 t.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) 07136 Page 4 of 4 TOWN OF SOUTHOLD PROPERTY ,,RECORD CARD ""~'-' OWNER STREET '~ ~ ', .~ . '(,~ VILLAGE DIST. SUB.~,~ LOT~'r.._~r~ ~: ~ ~S~S. VL. ~ FARM CO~. CB. MICS. : M~t. V=lue ~ND IMP. TOTAL DATE RE~RKS//~h~ ~/~/~ ~ ~ ~ J(~ rill:~le ~ FRONTAGE ON WATER N~I:~ FRONTAGE ON ROAD ~ DEPTH / ~' 0 ' ~ Plmt BULKH~D COLOR TRIM Extension ,~? X Extension Po~ch Ilorch Potio 0.8. T~al Foundation Basement Ext. Walls Fire Place Type Roof Bot~ Floors Interior Finish Heat Rooms 1st Floor Recreation Room Rooms 2nd Floor Dormer Driveway ~'/~/~' ..~j,(, /?~. ~ LR. ~),.~, ,~ ,fc.J. DR. inette BR. FIN. B bot ~D : ~ YOUNG & YOUNG 400 OSTRANDER AVEHUE, R)VERH[~AD NEW YORK ALfJEN ~ YOUNG HOWARD W. YOUNG SURVEYINLANDFOR:HoMES, tNC, ~,~: '" ' ' i.' :':"?~,': ,.~,. ~, LOT NO. 2B,"LAUREL COUNTRY ES3~,5,TE$'' ^~r LAUREL ~T~,~o '~o: SOUTHOLD SUFFOLK CO,, N.Y. t" = 40' oA'r'~:~,~,,,~ ~'PICAL ROOF CONSTRUCTION 'IBERGLA~S ROOF SHINGLES 5# BLDG. FELT CE SHIELD A~ SHOWN /2" PLYWOOD SHEATHING %OOF P-JNFTEP-,5 A5 PER PLAN :EILING JOISTS AS PER PLAN R-30) INSUL.@ FLAT R- I 9) INSUL @ CATH /2" GYPSUM WALL BOARD 12 2' X 4" TOP EL. WALK-IN CLOD. 3/4" PLYWOOD DUDFLOORING ( TCG ) CRAWL SPACE RIDGE VENT TYPICAL WALL CONSTRUCTION VINYL SIDING INFILTRATION BARRIER I/2" PLYWOOD SHEATHING 2" X 4" STUD5 @ t G" O.C. MATT INSUL. (R-I 3) I/2" GYP. WALL DS. I/2" ¢ THRU-DOLTS EA R.R. / C.J. CONNECTION I~ CATH CLG'5. CLG. HT. ~ M. DDRM 2" X 4" R- l 9 INSUL. @ I G" O.C. TECO~ BLOPED I lb" GYPSUM WALL DS. (~ WALL5 ¢,CLG. DRG, WALL MASTER BEDROOM FLOOR. JOIDTD AD PEP, PLAN TO ALIGN W/EXIST. VAPOR 5ARRIER TOP OF PM TOP OF DUD FL · D" P.C. FOUNDATION WALL 2" X 4' CONT. NE'rWAY SECTION A I/4"= I I-OH FOR ADDITIONAL INFORMATION REFER TO SHEET 4 ~) I/2" 0 THRU-DOLTS ) EA R.R. / C.J, CONNECTION ) CATH CLG'D. ;LC. HT. @ FAMILY Pdv~ 12 DLIq'G AD R~Q'D INSUL. PAMILY RM VENT 0" ~JDGE PLAN W/TECC)5 DAF. TOP OF PLK fOP OF 5US FL. 2" X G'" NAILER W/ TEGOD. REFER. TO DETAIL 51dEET 4 5UDFLOORiNG ( T*G ) TO DE FLUSH W/~XIDT. FLOOR JOISTS AD PER pLAN TO ALIGN W/EXIST, CRAWL SPACE GRD AD pER. PLAN 5ECTION B I/4"= I I - 01' FOR ADDITIONAL INFORMATION REFER TO SECTION ABOVE TOP OF DUD FL. GRADE /5" P,C. FOUNDATION WALL ON D" X I G" P.C. ErG. W'/ 2" X 4" CONT. KEYWAY gYP.) M. BATH HALL BATH KITCHEN ~,,1~ ~' ~'%'? I~,, 2,1 o [o u~v u,,v wc~ °~'l° DW. SCHEMATIC co PLUMBING RISER DIAGRAM N.%5. NEW ADDITION NEW DECK NEW ADDITION REFER TO CORNER HOLD DOWN DETAIL BELOW 20'-7" aII 8I' 5CR ?KT CRAWL SPACE 2" P.C. SLAB OVER VAPOR BARRIER I' 7'- I 0" '-I /,/NEW 2" X 8" FJ I 2.c. TO BE FLUSH W r ~l T,E ~LR To ~,ST. STEP ~G, 2: I M~ TO REMOVE EXIST. W1NDOW ~ROVIDE OPENING TO NEW CRAWL 5PACE ( ~LUE KELOCATEEXIgT. HTR TOTH, LOC^T,ON NOTE: PROVIDE 5/8" TYPE "X" GYPSUM SD, 2" X I 0" LINE OF DECK. ~/¢ STEP5 ABV 2" X I (3) 2" X I0" F.C. PIER ON 24" X 24" X 12" P,C FrG. (~¢PICAL) NOTE: ALL LUMBER USED ~$1 DECR5 TO DE TPJ~ATED. ALL HARDWARE TO DE GALV. I REFERTO SHEET 5 FOR LEDGER SD. REMOVE D(IDT. CONNECTION Gl AR~A 2" X 8'"'LEDGER SD. W/TEC05 REMOVE ~(19T. F.J ~ CANTILEVER. REMOVE ¢ RELOCATE EXIST, HTR @ BOILER AREA AD PER CODE ( I O0 5J=,) EXI5TING 0 EXISTING (3) 2" O-- (3) X ADD ~ I 3/4" X 9 I/2" LVL ~TO EACH IDE OF EXIST. GRD. USE I 2 LENGTH5% REFER TO DETAIL BELOW 8I' GIRgER 0 -- ---- J EXIST CELLAR GIRDER DLK. 50US UNDER NEW POET ADV. EXISTING 24'-2" I G"I~ 8" 5CF-, ~ ENT CRAWL 5PACE 2" P.C. 5LAD OVER VAPOR BARRIER I G" X 6" DLK PIER ON 24" X 24"X I 2' P,C, % FOOTING (?FPICAD I I 2" X 8" FJ ~ I G'"~, ___. TO DE FLUSH W/~XI,5't' I 5CR \ //NEW 2" X 6" I 6 TO BE W/I~ 8'-6" 5'- I O" ENT CORROSIVE T~ ~ TO ~IST. ~G. ~ICAD TIE NEW ?ND WALL EXIST CRAWL 5PACE PROVIDE OPN'G TO EXIST. EXIST UNEXCAVATED RETAIN STORM WATER mlNOFF PURSUANT TO CI IA?~ cn 236 OF THE TOWN CODE. ~MOV[ ~X~ST.~ND WALL TO ALLOW FOR 10LO" OH DR COMPLY W!TH ALL CODES OF NEW YORK STATE & TOWN As REQUlF .,,,ND lJ //JJ SOL~OLOTOWNZBA SOUTHOLD TOWN PLANNrNG 80ARS .-~. 80UTHOLD TOWN TRUSTEES NY,8, DEC EXIST. F.J. , FOUNDATION FLOOR PLAN I/4"= I '-0" EXISTING (3) 2" X 6" TYPICAL FOUNDATION 8" POURED CONCRETE WALL ON IG~' x 8" P.C. FOOTING W/2" x 4" CONT, KEYWAY, (2) 2" x G" TREATED DILL pLATED, 5ILL 5EAL, TERMITE SHIELD ¢ DAMPPROOFING. 5/D"0 ANCHOR BOLT OCCU, ' kIOY OR USE 15 UNLAWFUL WITHOUT CERTIFI( OF O00UPANOY APP~V~D AS NOTED 7BB-180~, 8AM TO 4PM EOR THE FOLLOW~3 INSPECTIONS: 1. FOUND]~TION - TWO REQUIRED ' FgR P.~JRED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST DE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NBA YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. NAIL~ ~ GIi OiC, PR~DEFLECTED HOLDDOWN (EITHER SIDE) CERTIFICATION OF' NAILING ¢~DERWRffERS CERT~OA~ TYPICAL CORNER REQUIRED --I A L L C 0 N ST R L ~;~i(~¢sH(~ CODE~ OF N~ ry~F~K STAT ON L~D CON~ :~BEFO~ OERTIFICA TE O~ ~UP~ ' SOLDER USE[ ~ATER 8UPPL Y SYST~ ~ANNO~ EXCEED ~I0 C ~'~ LEAD THE :. COL, Bk"ON D DETAIL ADD I 3/4"X 9 I/2"LVL TO EACH 5IDB. THRU-DOLT W/ 1/2" ¢ DOLT5 @ I 2" O.C, STAGGERED. U5E I 2' LENGTH~. SIMPSON OR EQUAL HOLDOWN5 TO DE PROVIDED AT CORNER5 OF NEW BUILDING AND AT OPENING5 GREATER THAN GLO" WIDE DEE DETAIL5 THI5 SHEET. TYPICAL ANCHOR ~OLT5 5/8" I~ X 53II C.C. W/MINIMUM EMDEDMENT OF 7" WITH 3" X SQUARE WASHER, HOLD l 2" OFF CORNER.5 AND 4" TO I 2]" OFF EACH END OF EACH 5ILL PLATE. PROVIDE LIpLIh-f 5TP-.A? CONNECTION5, SEE DETAIL 51tEET # A-. / 2'- I" DH Dd NAIL5 @ 4" O.C. EDGE5 D~l NAIL5 ~ 4rI O.C, I LSd NAIL5 ~ 4" O.C. A5 SHOWN -- ALL EDGE5 ELEVATIOIW VIEW WAI ,l, BRACING DETAIL HOLD-DOWN PLAN DETAIL r ~.,~ PLUMBING J Date: 10~24~07 A,L~,~.~" tll~ ~E sWNAESET~E m I ~ n ML~rOJ # 07 13(;; FND5 \ , TESnN~ SEFORECO, V~J.~;, ' ' PREDEEIZCTED HOLDDOWN ' - (EITNER BIDE) 5/8" ¢ ANCHOR DOLT CNW COUPLER NUT5 coMPLy'WITH cHAPTeR 46 FLOOD SouTHOU Drwn. by: DKvTC Chkd. by: dk PROVIDE 51MPDON A55 NEW ROOF BHINGLEB RIDGE VENT NEW 2" X G" C,J. (~ I G" O.C, WJ TECOD EXIDTING RA~TEP-.5 ~15 INDUL NEW CLG. F. ~ NEW LVL W/BR~.~/ tlJ : ........... ~- KNEEWALL ABV I I REMOVE EXIBT. WALLS (' CLG. TO RIDGE I I (MID A&~. ~PAI& FL,, * WAL~ ~ ii ~REQUI~D, MATCH NEW CONDITIONS ~ R~TCHEN ~ DINING ~OOM b [~ '~ EXIDT. CEL~& ~iDT. COL 6KIBT. FTG. SECTION C I/4" = I '-0" GENERAL DEMOLITION NOTES: I . FIROT FLOOR: - REMOVE ALL WALLS. CEILING JOISTS, AND ROOF P-,APTEP-,5 WHERE SHOWN. - REMOVE ALL PLUMBING FIXTURES AND APPLIANCES WHERE SHOWN. - REPAIR EXISTING WALL5 TO RECIEVE NEW PARTITIONS WHERE SHOVeN. 2. ALL PLUMBING, HVAC, AND ELECTRICAL COMPONNENTS TO BE DISCONNECTED, CAPPED AND REMOVED OR REROUTED AS REQUIRED. 3. ALL WINDOW5 TO BE REMOVED AND REPLACED AS PER PLAN. REPAIR OPENINGS AS REQ'D. TO ACCEPT NEW OR RELOCATION. 4. CONTRACTOR, SHALL CLEAN AND PREPARE EXISTING ELOOR TO BE READY FOR NEW FLOOR AND FINISHES. EXIST, WALLO. REQ'D) AD REQUIRED. MATCH )NDITIONB ~RIFY [ JTD. NOTIP¢ ir IE LAPPED lB WALL. EXIST. BEDROOM 20L7" NEW DECK 24'-2" NEW (BUILD THIS ROOF FIR`BT) ~L4" ~'0" ~'-4" c 14 P4O4O c 14 WE) STEP5 W/H R NOTE: POST EA END III ii ~-- TO GR`ADE AD REQ'E ] OF HD,°-. SOLID (TYP) i (a)2,,~ io,, % , ~- i i TW 2652 TW ~_~,52 i RAILING T (2) 2" × ,5" J (2) 2" X a" % / ~ ~ CLi~. ,, , ~F,C^U aO,.7,, 4,, ' ~ D'-~" b.&, a .,_0,, aJo,, .,, ~ c~o~. ~ ~z'x~"~.~.~tCo., ' ' ~ -- ~ 8o u I 2"X&'IC.J, ~lG"ox // m i ~" ~ m CbG. HT ~ D~ DOT. ~ 9'-6" A. =.~, ~ ~ ~ //2" X ~ ~ ~ ~ ' ~ 2"XS"C.J. ~16"o.c. // 6 ~ ~ J I ~ CA~I~ A~V )J -, ~ NEW DEC~ ~ ' m ~ m ~ ~ m ~ ~ , m // 5/4" DECKING ~ m CT~. W. N~E= VENT ~ m m - mm ~ :AD'5 A ~LO" m m ~ m m ~ ~10~ ~ m m ~ , ~AM reLY ~OOM m , , ~ , .."m ¢ m ~ 4" X ~ mm ~ C ~ m ~ m ~ ~ 3LO" m ~ ~ 4,, 2'( O. ~,, 3,-~" ~,, I ~ ~ ~ ~ (!~ 2" X I O' '~ NLGD33G~5 NLGDGOG~R NLGD33G~5 m )m o ~ O~ o ~,~ · ~: DINING ROOM 0 N m ~ ' '~>~ ~ o ~"x ~"d ~ ~ xx ~ ~ % 12'-0"/~,, ,2'-0 ? 4'-3" ,4" ~ 5 k 20'-7 J 4"~ I -~ f ~ %~MOVE~ST.C.J. ~ J ' ~ - --' ~ '--'~-' ~ ...... m~ ----~1 ~¢t~"A~ WlT[,:05~-- -- ~-~ D~D~OO x ~ ~ u~w ~OLO ~S ~ ~ ~ LVL ~ _~ ~ ~ D~D~OOM ~ " _~ ~ ~ITCH~N ~ ~ ~ ~I~T, GA~G~ o° ~ ' ~ ' ~ ~°O~O 'd ~ ~= '.,~ 50 C~M~'P' x mm (2) Z" X l 2": (2)~mm302 I 0 ~" ....... ~ - ~/~EW 2,m-~,, ~7 ~ ........ ~-~ z ~ ~ ~ IG"~'C'OV~F" 4" 2'¢' 4" I~'-0" 4' ~ 5'-0" ~ 4" P.C. FA~ ~ ~ ~ '~~, ~ e (2) m 3/4"X 9 )/2" LVL (2) 2"X I0"~ --~ ~ -ju ~= (2) TW3042 (3) 3C ~2 OVE ~IBT,~NDO~. ~ ~ER TO INSTALL NEW ~ SHOWN D~AIL ,; I 0'-¢" I ¢-¢" 3LO" ~ 6'-2" J 2'- I" ~ 2'- I" 24'-2" +/- ~lBT. 4,_6,,, 2 I ,.4,, +/. ~lBT. I ¢'- I O" +/- ~lBT, 64L4" ~IBTING REMOVE EXIST. BATHRM ~REPAIR FLOOR AD FIXTUREB. CAP OFF ALL / FREQUIRED TO MATCH REMOVE EXIST. WALLS, PLUMBING. REPAIR / EXISTING /CLG. ¢ ROOF THIB AREA. FLOOR AD REQUIRED / /REPAIR PL., * WALLO AD ~ - CHIMNEY NEW CONDITIONS DINING II KITCHEN EXIBT. I[ FAMILY Rivl. R~MOVE EXIST. CLG, THIS AREA. EXIBT. GAP. AGE ~-r -~/ '~ WALLS. REPAIR PLO /il H AB R~QUIRED BEDROOM II II EXIBT. BEDROOM )H NOTE: CLOTHED DRYER D(~AUD'T TO BE INOTALLED IN ACCORDANCE WiTH ~ECTION I 501 OF Tiff E REglDENTIAL CODE OP NEW YORR NOTE; VENT N '~' EXTERIOR 4" X 4" PC~TO ¢//GALV. CAP ¢ BADE ANCHOP, O · ALL BRACING REMOVE ID(mDT. RXTUREB. CAP OEP ALL PLUMBING. REPAIR FLOOR AD REQUIRED REMOVE EXIST. OH DOOR MAKE OPN'G W1DER TO ACCEPT NEW ~0' OH DR. FIP-,,BT FLOOP-, PLAN I/4" = I I-0" EXIST. AREA CALC. FIRST FLOOR.: 1342,5.F. GARAGE: 361 .5.F. TYPICAL WINDOW/PATIO DOOR NOTE: ALL WINDOWS ¢ EXTERIOR PATIO DOORB ARE TO DE MANUEACTURED BY ANDEROEN. DERIEB 400. WHITE PERMADHIELD, HIGH PERPORMANCE LOW E GLAZING,BCREENB, BTANDARD HARDWARE. PROVIDE EULL WALL WlDTfl E3~TENBION JAMBB AS REQ'B,. PROVIDE FACTORY INBTALLED MULLIONB AB RfQ'D.. ALL UNITS TO HAVE A MIN. DP SO RATING, INBTALL ALL UNITS AD PER MANUFACTURE'B BPECB. FLOOR, AREAO: F___XIOT.FII~OT FLOOR`: 1342 O.F. NEW CONOTR`UCTION: 997 5.F TOTAL: GARAGE (EXIST): P-.EA P.. DECK: 2339 5.F. 36 1 5.ff. 412 5.F. WALL LEGEND EXIST. TO REMAIN TO BE REMOVED NEW 2" X FRAMING (AB NOTED ON PLAN) NEW END. WALL ] E ] zrV' z 0 j Date: 10/24/07 Proj. #: 07.136 Drwn. by: DK/TC Chkd. by: dk sheet no. 2 DEMOLITION PLAN I/4" = I '-0" PL, HT BUBPL NOTE: REMOVE EXISTING ROOf= SHINGLES AND SIDING. INSPECT AND REPLACE ANY DETERIORATED SHEATHING. INSTALL NEW MOISTURE BARRIERS, SIDING AND SHINGLES. ~PL. HT. ~BUBFL. 2LO" ~ OCREENED LOUVERED VENT ROOF BHINGLE5 L/./~ RIDGE VENT I 2 -I 2-- DECOI~ATIVE :- -i ' rli, -I' Il ,' , = = ,/ ,J I ~ I DEC01 ~TIVE BHLFFFER,5 · I I ~ I ~ FR.( ,~T ELEVATION ~555~5~~ ///// '~ ~[~ -- I //~" I i /~'~P (~OW~ I r REMOVE ~IST. % // NEW VIN% SIDING ~ DECO~TIVE PANE~ ~MOVE ~IST, ~MOVE ~IDT, / UFW ~/lU~ qrnlkl~ / SHOWN) WINDOWS. PILL OPN'G WINDOW~ WINDOW5 FLUBH BOTH BIDEB NEW EXIBTING EXIBTING ~ISTING I STEP ~G FRONT ELEVATION I/4" = I '-0" 12"¢ P.C. PIER 3' BELOW GRADE TYPICAL NOTE: NEW VINYL SIDING ENTIRE HOUSE NEW ROOF SHINGLES ENTIRE HOUSE NEW ADDITION NEW DECK NEW ADDITION TPL. HT. ~BUDF ROOF BHINGLE5 L.~ RIDGE VENT 2' ,Q" ~ .m. CREENED BLIND RIDGE HT I G" X B" VENT VINYL BIDING 3' HIGH RAIUG W/ F WD STEP5 W/HR 2" X 2" DALU,STER5 TO GRADE AD REQ'B I ~ @ 5" O,C. (TYP) L FLJq ~ J~ ~ ~ ON 24" X 24" X I 2" -- -- STEP FTG STEP FTG ~ j P.C. FTG. (lh'PICAL) 2:1 MAX 2:1 MAX j REAR 5TE?FTG ELEVATION I/4"= I '-0" PL. HT. BUDFL. ~ GP-,ADE EXXIBTING REBIDENCE NEW ADDITION NEW ADDITION EXISTING R[51DENCE BLIND PL. HT, 0 NEW I O' X 7' OH DOOR I ,, I VIN% 51DING VINYL 51DING ,% ~ Date: 10/24/07 5U~FL. ~ Proj, ~: 07.13G G~DE VENT ~ILL OPN'G PLUSH BOTH J ~EMOVE ~IDT. ¢' OH DR WD 5TEP5 W/H~ J 5CR VENT 51D[5 ~ ~Q'P T,'O ACCE~ * ~P~CE W/ I O' OH DK TO G~DE ~ ~Q'q I J L ak -- L ~ _ 3' BELOW G~DE STEP ~G I ] J ~ICAL) no. LEFT SIDE ELEVATION I/4" = I '-0" RIGHT 51DE ELEVATION I/4" = I '-0" 3 CONDTP--.UCTION NOTE5 ENERGY NOTE5 EGR. E55 WINDOW SCHEDULE (ALL 5LEERING ROOMS) SAFETY GLAD5 REQUIP-ZMENT5 AFCPA WOOD FP-,AME CONSTRUCTION 1:395 EDITION FASTENER SCHEDULE FOR 5TIRUCTUP-,AL MEMDER5 NUMBER AND TYPE SPACING OF FASTENER8 DESCRIPTION OF BUILDING ELEMEHTS OF FAETENER ROOF FRAMING BLOCMNG TO JOIST, TOE NAILED 2-8d EACH END ~LOCEING TO 5ILL OR TOP PLATE ( TOE NAILED) 3- I Gd EACH BLOCK LEDGER STRIP TO BEAM (FACE- NAILED) 3-I Ga EACH JOIST JOIST ON LEDGER TO DRAM (TOE NAILED) 3-8d DER JOIST DANE JOIST TO JOIST, END NAILED $-I 6d PER JOIST DANE JOIST TO SILL OR. TOP PLATE (TOE NAILED) 2- I Gd PER FOOT SOLE PLATE TO JOIST OP. BLOCKJNG. FACE NAIL (~1 J ~ I 2" O.C. G.W.B. j 5J::tCOOLER~ I 7"EDGE/ IOI'FIELD 4" FOR ATTACHMENT OF ROOF 5HEATHrNG TO GADLE WALLS. 2" X 2" DALISTER5 l/2" CDX ROOF SHEATHING RIDGE BEAM A~ PER PLAN ~ 5" O.C HOLD PLYWOOD DACE FROM RIDGE EOR AIR CIRCULATION CAP SHINGLE AT RIDGE VENTS CONTINUOUS PJDGE VENT AS PER PLAN BUILDING FELT (SEE PLAN) NAILED TO JOIST5 ROOF SHINGLES PEK PLAN PROVIDE HANGERD@ I 1/4" x 200a BTEEL STRAP EVERY CATH CLG'B (4) Scl NAIL~ EACH END, C.T.rS ~ 32" O.C. OK DECKING ~LLAR TIE5 @ I G' O.C. MAY DE SUBSTITUTED ~ D~CKJOISTS~PERP~N ~ ~ ~ POST ANCHOR. '~ (5} 8d ~ ~E~ ~. CONN~O~ SIMPSON PD 5E~E5 (5) 6d ~ P~TE EA. CONNE~O~ (~ TO TOP P~Tm) DECK DETAIl, (CLG. JTS.) ~F~ TO T~-DO~ / CONN[CO~ e ] 6" O.C. C~20 5T~PS.HDE TO STUD, (5) Cd ~ P~TE ~ AND FOUNDATrON WALL JOIST HANGER -- PROVIDE I¢ ¢ 1 6" O.C, STAGGERED ¢ DOUBLED @ EA END @ EA LEDGER ED. CONNECTION TYPICAL DECK FRAMING DETAIL AT EACH CRIPPLE 5TUD. TOP AND BOTTOM -- PHD5 HOLDOWN REQ'D AT ALL OPENING5 GLO" WIDE ¢ GP, J~ATER ,STUD TO BTUD, 5/&' 0 ANCHOR BOLT @ DB" O,C, HOLD G" - I 2" OFF EACH END OF EACH SILL PLATE. MIN, EMBEDMENT 7" INTO CONCRETE 16" O.C. (5) IOd NAIL~ EACH END* LTP4 5ILL PLATE TO RIM JOIST. ( I 2) ,~d OR C520 5TRAPS ~ I 6' O.C. RUN UNDER BILL PLATE5 AND UP STUD, MINIMUM (4) I Od NAIL5 ~JkCH END OR BTUD TO BILL @ 0.C.(5) I Od NAIL~ ~ EACH TIE DOWN /FOUNDATION DETAIL END,(42" LONG MIN.) TYPICAL HEADER OPENING CLIMATIC AND GEOGP-,APHIC DESIGN CRITERIA GROUND 5NOW 45 PDF LOAD WIND SPEED 120 (re?h) SEISMIC DEDIGN CATEGORY C WRATH- 5¢VERE ERING FRODT ~UDJEc'r UNE ~'-0" TO DAMAGE TEE. MITE MOD-TO FROM HEAVY 5LrGHT TO DECAY MODERATE UNDERLAY- YES CODE ANALYSIS ASPHALT ROOF SHINGLE NOTE ASPHALT SHINGLES SHALL HAVE SELF- SEAL STRIPB OR. DE INTERLOCKING, AND COMPLY WITH ASTM D 225 OR D 3462. 2. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS, ALUMINUM, OR COPPER ROOFING NAILS. MINIMUM 12 GAGE 5HANIC. ED WITH A MINIMUM 3/8 INCH DrAM~ER HEAD, OF A LENGTH TO PENET~kTE THROUGH THE ROOFrNG MATERIAL5 AND SHEATHING. 3. ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUM~SER OF G EASTENE~5 REQUIRED DYTHE MANUFACTURER. ( G MTN.) 4. FOR. NORMAL APPLICATION, ASPHALT SHINGLES SHALL BE SECURED TO THE ROOF WITH NOT LESS THAN SIX F~STENER5 PEP. STRIP SHINGLE OR TWO FASTENER..5 PEP-. INDrVIDUAL 5HINGLZ. 5. ROOF COVE~.ING MATERIAL~ (SHINGLES) SHALL DE DELIVERED IN PACF. AGES BEARING THE MANUFACTURES IDENTIFT]NG MARF.5, Da~e: I 0/24/07 Proj. #: 07.136 Drwn. by: Dr,/I-C Chkd. by: dk ~heet no. 4