HomeMy WebLinkAbout33581-ZFORM NO · 4
TOWN OF SOUTHOLD
BUILDING DEP~RTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-33478 I~]te: 01/08/09
11{IS CERTIFIES that the building ADDITIONS/ALTERATIONS
Location of Property: 3895 DELMAR DR LJkUREL
(HOUSE NO.) (STREET) (HAMLET)
Co%k~ty Tax ~lp NO. 473889 Section 125 Block 4 Lot 2
subdivision Filed Map No. __ Lot No. __
conforms substantially to the Application for Building Permit heretofore
filed in this office dated NOVEMBER 1, 2006 pursuant to which
Building Permit No. 33581-Z dated DECEMBER 13, 2007
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ALTERATIONS AND ADDITIONS, INCLUDING DECK, TO AN EXISTING ONE FAMILY
DWELLING AS APPLIED FOR.
· ~ne certificate is issued to ALBERT C NAEKEL III
(OWNER)
of the aforesaid building.
SUF~LKC~3~I~fDEPAR~TOF ~L~"~PRO~-AL N/A
ELEt-rKICRkL CI~RTIFIC~TE NO. 123545C 09/19/08
pL~ER~ CERTIFICATION DA'r~3 12/23/08
CLASSIC PLUMBING & HEAT
uthori~
Rev. 1/81
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworu statement from phimber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction:
Location of Property:
House No.
Owner or Ownem of Property:
Suffolk County Tax Map No 1000, Section
Date.
Old or Pre-existing Building: b/ (check one)
Street Hamlet
Block ]Z-fi'. -~'/~ Z Lot
Subdivision
Fe,mNo.
Date of Permit.
Filed Map. Lot:
Applicant: /jr O~-e~' C.-
Health Dept. Approval:
Underwritem Approval:
Planning Board Approval:
Request for: Temporary Certificate
Fee Submitted: $
Final Certificate:
V/'" (check one)
Applicant Signature
Issue Date
9/19/2008
Electrical Inspection Certificate
Electrical Inspection Service, Inc. Application Number
375 Dunton Avenue 123545C
East Patchogue, NewYork 11772
(631) 286-6642
Issued To: Mr. Albert C. Naekel III
Street: 3895 Delmar Drive
Village: Laurel Zip: 11948
Section: 125 Block: 0004 Lot: 0002
Contractor: Three Brothers Electric Inc.
Town: Southold
Lic,# 3792-E
Was examined and found to be in compliance with the National Electrical Code.
Commercial [:~ NVDefects ! Pool i-X] lstFIoor IX Indoor [Xl Basement i i HotTub
Residential ~!J Det. Garage ~1 Attic ~ ~] 2nd Floor iX Outdoor ~ Addition ill Survey
Switches Receptacles Fixtures GFI Heaters AJC Fans
39 54 51 4 2 3
Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwaves
1/20a 1 20 1 30 2/20a 1 Gas 1/20a
Furnace Oil Gas Circulators Smoke Detector Bell Transformer
I x 3 5 1
Meter Amps Phase UG/OH Jacuzzi Television CO Detector
Bldg. Permit: 33581Z
Other Equipment
~_-30 ~mp A/C ~isc./1,~ra~e Door opener
Recept.
Hugo S. Surdi
President
06/11/2008
John Mc Mahon III
This cedificete must not be altered in any manner. Inspectors may be identified by their credentials.
Town I Tall Anncx
s4375 Main Road
PO. Box 1179
Saulhold. New York 11971 0959
][3 UILDING DEPARTMENT
TOWN OF SOUTHOLD
CERIIFICATION
(Please print)
Icad.
I cmtlfy that thc soldel uscd U', the water supply system contam~ less than 2110
(Plumbers Signaturm
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 33581 Z Date DECEMBER 13, 2007
Permission is hereby granted to:
ALBERT C III NAEKEL
3895 DELMAR DRIVE
LAUREL,NY 11948
for :
ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR.
at premises located at
County Tax Map No. 473889 Section 125
pursuant to application dated NOVEMBER
Building Inspector to expire On JUNE
3895 DELMAR DR LAUREL
Block 0004 Lot No. 002
1, 2006 and approved by the
13, 2009.
Fee $ 423.60
ORIGINAL
Rev. 5/8/02
TOWN OF SOUTHOLD BUILDING DEPT.
765- t 802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
FRAMING / STRAPPING [ ~'FINAL
[ ] FIREPLACE & CHIMNEY
[ ] FIRE RESISTANT CONSTRUCTION
REMARKS:
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
DATE Io~2-~ -D ~ INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ]FOUNDATION 1ST
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ] ROUGH PLBG.
[ ] INSULATION
[~INAL
] FIREPLACE & CHIMNEY
] FIRE RESISTANT CONSTRUCTION
REMARKS:
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
DATE / ~ ~/''~'~ ~ ~ INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INACTION
[~J~INAL
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ]RRE RF. SI~_ CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARK~I~'~-~ ~ .~
DATE ~~--- INSPECTOR ~~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ]~ PLBG.
[ ] FOUNDATION 2ND [~'~ INSULATION
[ ]FRAMING/STRAPPING [-]FINAL
[ ]FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION
[ ]FIRE RESISTANT CONSTRUCTION [ ]FIRE RESISTANT PENETRATION
REMARKS:
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
FIRE RESISTANT CONSTRUCTION I~/~ FIRE RESISTANT PENETRATION
[
REMARKS:
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-t 802
INSPECTION
[ ]FOUNDATION 1ST ~~.
[ ]FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]FIRE RESISTANT CONSTRUCTION
REMARKS:
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] F~ION 2ND [ ] INSULATION
~*/~~TRAPPING [ ]FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
DATE
INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] F~UNDATION 2ND [ ] INSULATION
[v~'FRAMING S~RAPPING x--,~ [ ]FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS:
] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
DATE
~/~/'~//0 ~ INSPECTOR ~~
335~/.7~ ~
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
] FOUNDATION 1ST
~FOUNDATION 2ND
[ ]FRAMING / STRAPPING
[ ]FIREPLACE & CHIMNEY
[ ]FIRE RESISTANT CONSTRUCTION
[ ] ROUGH PLBG.
[ ]INSULATION
[ ] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
REMARKS: ,.
DATE
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[
ROUGH PLBG.
~-'~FOUNDATION 1ST
[ ] FOUNDATION 2ND [ ]INSULATION
]FINAL /
]FIRE SAFETY INSPECTION
[ ] FRAMING / STRAPPING [
[ ] FIREPLACE & CHIMNEY [
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS:
m£o ~s~,scrio~ m, oa~ I ~ ~ co~s
PLL~G ~ ~Zad ~ ~' i ~
STATE ENERGY CODE
~DITION~ CO~ENTS ~
TO%VN OF SOUTHOLD
BUILDING DEPAR~Ti~IENT
TO%VN HALL
SOUTHOLD, NY 11971
TEL: ~63t) 76~i802
FAX: (631) 76~9502
x~-. n orthfork.nel/Soulhobt;
BUILDING PEYGMIT APPLICATION CHECKLIST
D:, yo.* have ,.,r n~ed th~ folh, a,.mg. ;,~for. applTin~"
~oard ,,f ~Ath
Cantact:
APPLiCATiON FOR BUILDING PERMIT
Date
INSTRUCIIONS
a. ~ltis application MUST be completely filled in by ~-pewriter or in ixtk m~d subnfitted to the B~l&ng ~speetor ;;4th 3
sets of plus, aecm'ate ph, t plm~ to scfle. Fee aecor~ng to sehed~e.
b. Plot pi~ sho;~ng locati~ of lot ~d of btfil~ngs on pre~ses, relations}tip to adjoimng prcnfiscs or public ~n'eets or
e ~e w~,-k- covered by tbJs ~pp!i~fio~ m~y p,~t be eo~mcm:*l bcf, x'c issumcc ofBuildh~ Pcmfit.
d. Upon approv~ offs applicafi~, the Buil(hng h~spcctor will issue a B~l~ng Pe~t to the applicmm Such a pem~t
sh~l be kept m thc pre'scs av~lable k.r inspection fln'oughout thc work
c. No buil~t~ shMl be occupied or used in whale or in p~ ~br m~y pnpose what so cvcr until the Bt~lding h~spcctor
issues a Ce~fieate of Occupm~cy.
f. Ex.~ bnih~g p~ufii sh~l ~pi[e if the work au~mfized has nO conancnced wi~fin 12 mon~ts ariel rite dale of
issum~ee or has not been convicted ;~4tlfin 18 ~nonths fi~om such date. If no z~ng mnen~cnts or other reaOafions afi~c~a the
addition six mont~. ~erea~er, a new pm~fit shMl bc req~md.
APPLICA~ON IS ~BY N~DE to the Buili~ng Depm~mct~ ~br the issumee ora Btfilding Pemfit pt~su~t to the
Btfildi~ Zone Or~tm~ee of the Town of Southold, Suffolk Com~,, N~' York, md off,er applicable Laws, Ordinmces
Re~ulatlons. for the constt a~fion ofbGl~ngs, ad~fions, or ~teratim~s or t%r mmov~ or dcmoiifion as herein described. ~le
applicm~ a~rees to eoraply with Mi applicable laws, ordinm~ccs, b~ng code, Bottling code, mid rcg~lation~,
(/ignamre ,vf appiicomt ~,r nmne, if a co~oration)
(~{~dlir, g ad& ess of a~,plicant)
State whether applicant is owner, lessee, agca~t, architect, engineer, ~neral contractor, electrician, plnmber or builder
Name of owner of premises gL~ff'~'7~ C /V~J~rJ~'&'~ /~
(As on the tax roll or late.~ deed)
If applicant is a coq)oration, si ~mmture of duly authorized officer
(Nanm and title of corporate officer)
Builders License No.
Plumbers License No.
Electiidmis License No.
Other Trade's License No.
I. Location of lead on which proposed work will be clone:
37q ' P,ezm ,e vd
House N mnber S~'eet
Com~E~, Tax Map No. 1000 Section
Subdivision d~
(N
Hamlet
Filed Map No.
Lot . ff
2. State existinr, use and occupancy' of premises and itRended use aid occupant' of proposed coustmcfion:
Existing use vad occupang'
b. intended use sad occupan%'
3. Nature oi wak (check which applicable): New Building. Adchtion
Repair Removal D em olili on Oth et' Vqork
Estimated Cost ,~,tggg/ ~flboe2, ~
5. If dwelling, number of dwelling uats
If g~mge, number of c~rs
Fee
Alteration
(D escripti mil
iTo be pa~d on iliag th~s applicatioa~
Number of dwelling units on each floor /
6. d business, commercial or mixed occupancy~ speci~, nata'e and extent of each tv~)e of use.
7. Dima~sions of exd~ing strnctures, if any: Front ~tt'~* Rear ~/(-/~? Depth ,~'~
Height /~ t Number of Stories /
Dimensions of same structure with alterations or ~dditions: Front ~(, ~fir~ Rear
Depth ,.¢"~> ' 0 * Height. /~' Number of Stories
8. Din, ensions ofentkenew consti'uction: Front Ct/¢ ~'~* Rear ~J2'/0' Depth
Height /~, ~ Number of Stories /
9. Size of lot: Front /519' Rear /,~t~ ' Depth /~flO '
10. Date of Purchase ,~ghCO Name ofla:onner Owner ,~8~/r'&? /~/J/~'/t'¢/.
i i. Zone o~ use district in which pt~mises ae situated
13. Will, ~,
14. Names of
Name of Architect~
Name of Contractor Ad(kess Phone No.
15 a. Is this propem/within 100 feet of a tidal wetland or a fi'eshwater wetlaud? *YES NO /~
' zF '5 ~ S, oOb 2XtOLD TO¥~ N TP, E, STEE S & D.E.k_ PEPd~ii z ~ M~'k BE RE QUI~ED.
b. ls fins properS; within 300 feet of a tidal we~ianfl? ~ ~'~S, ~, NO
* IF YES, D.E.C. PERMITS MAY BE REQUESTED.
16. Prov.de .mve¥, to .~ca.e, wt/n accurate foundation plan and distances to properPy lines.
17. Ii elevation at any pant on properS- is at 10 ted or bdow, mub{ provide topographical data on atrvey.
S TA TE OF NEW ¥OKKi
SS:
CO[%T7 OF }
~_£ ~-Z[ e ~ ~ bein~ d~y s,vom~ deposes m~d says flint (s)he is the applic=t
(Nm~e ofin~x~du~ sigMng con. act) above n~xed,
(Contractor, Agent, Corporate Officer, etc.)
of said owner ,.,r owners, m~d is (My autht~'ized to pert'om~ or have peffmned the said work m~d to m&e md file thts application;
that all statements contained in tiffs application m'e tt-ac to the best of his knowledge mid belief; and that the work will be
performed in 6~e rammer set font~ m fnc apptieai on fikd tim ewitk
Notaty'¢'~SblieTM
Signat~ n'e of Applicant
Public, State of Ne~Yoi'~
No, 02ST5027579
Oualified in Suffolk Cou.t~.,
~mlnlis~ion Expires May 9, gOD'?'.
HOME. IMF)ROVEM~NT
CONTRACTOR
LICENSE
KENNETH M MOSKELAND
43738-H 7
r~v,~,~ ~ tl/~1/2009
Norseman Building Corp.
444 West Jericho Turnpike
Huntington, NY 11743
tele: (631) 692-5050
fax: (631)692-5904
November 8, 2007
Mr. James Richter
Southold Town Hall
P.O. Box 1179
Southold, NY 11971-1179
Dear Mr. Richter,
This note is to remind & restate what we discussed in our conversation on
November 2, 2007 pertaining to question #7 on the attached form. The existing
driveway is to remain as is a~d is not included as part of this project.
Very truly yours,
NORSEMAN BUILDING CORP.
Kenneth Moskeland
Vice President
Town -of Southold
~ L.~' ~Eroslon, Sedimentation ~ A85E88MENT FOR~
~;'~ ?ROPERI~ LOCA~.TIOH: 8.C.T.M.~: THE FOLLOWING A~ION8 ~y REQUIRE ~E 8'""~""q" OF ·
" ~ ~C~ ~ 'c~ 8TOR~WATER G~DING D~I~OEAHD ~081~N'; '~ ....... ~ '
Illem Number:
1
2
3
4
8
9
(NOTE: A Check Mark (~) for each Question Is Required lot a Complete Application)
Yes No
Will Ihle ProJeot Retain All SIorm-Water Run-Off Genereled by a Two (2") Inch R~lnfell on Site?
(This Ilem will include all mn-off creeled by site cleadng and/or conslmctlpn ectlvllles as well as all Sile
Improvement~ end the permanent creation of impervious surfaces.)
Does the $lle Plan end/or Survey Show Ail Proposed DreJnage Slmctures IndlcaUng Size & Location?
Tiffs Ilem cheil Include ell Proposed Grade Changee and Slopes Conirolling Surface WaterFIowl
Will thle. PiloJecI Require any Land Filling, Grading or Excavetlco where there Is a change to the Natural
Exleling Grade Involving more Ihan 200 Cubic Yards of Matedal Wflhln any Parcel?
Will this/lkopgcadon Require Land Dlslurblng Acllvltles Encompassing en Area In Excess of
Five Thousand (5,000) Square Feet o! Ground Surface?
Is them a Natural Water Course Runn ng through the Site?
Is this Project within Ihe Troslees Judsdiclion or within One Hundred (100') feel of a Wetland or Beach?
Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vedical Rise Io
One Hundred (100') of Horizonlal Distanc. e?
Will Driveways, Perking Areas or other Impe~,ious Surfaces be Sloped to Direct Storm-Water Run-Off
into and/or In the direction o! a Town rlght-ol'-way?
Will Ihte Project Require [he Placement of Material, Removal of Vegelation and/or the ConsImction of
any Item Within Ihe Town Righl-oI-Way or Road Shou der Area?
(This Ilem wlH NOT Include the Installation of Driveway Aprons.)
Will this ProJecl Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercourse?
NOTE: IlAny Answer to Questions One Ihrough Nlnb Is Answered with e Check Mark In the Box, e Storm-Water, Grading,
Drainage & Erosion Control Plan Is Required end Must be Submitted for Review Prior to Issuance of Any Building Permlll
EXEMPTION: ~
: Yes No
Does this project meet the minimum slandards for classilicaiton as an Agricultural Project?
/
Note:
If
You
Answered
Yes
to
this
Question,
a Storm-Water, Grading, Drainage & Erosion Control Plan I$ NOT Requlredl __ ,~
STATE OF NEI~ YORK,
cou~rr~ ox .................................. /. .......
~.~, ~~ c · '~ /~ ~. '
...................................... · ~ ......... ~. ............. bcmg dui) sworn, d~poscs m~d s~ys d~a~ h~shc ~s d~ applicant [~r Pcrm~
O~n~r ~or repr~en~ve o[ dm Owner o[ 0~ net s, mul ~s duly authorized to perlbnn or have perlbrmed Ihe ~d work and to
m~e md file fld~ application; O~at ~1 ~temen~ tongued m ods appli~on a~e ~e Io O~e best of his B~o~vle{lge and beliefi
· at ~e ~rk ~1 ~ performed in fl~e m~mer' set [ortb in O~e application filed herewid~.
Sworn ta ~fore me dti~;
FORM -06~07 ~o"~
REScheck Software Version 4.1.0
Compliance Certificate
Project Title: 07.136
Report Date: 10/24/07
Data filename: F:\MEC AND RES CHK PROJECTS\07 Projects\07.136 NAEKEL rck
Energy Code:
Location:
Construction Type:
Heating Type: Non-Electric
Glazing Area Percentage: '14%
Heating Degree Days: 5750
Construction Site:
New York State Energy Conservation
Construction Code
Suffolk County, New York
Detached I or 2 Family
Owner/Agent:
ALBERT NAEKEL
3895 DELMAR DRIVE
LAUREL, NY 11948
Designer/Contractor:
GARY D. CANNELLA ASSOCIATES
55 KNICKERBOCKER AVENUE
BOHEMIA, NY 11716
Maximum UA: 470 Your Home UA: 470 = 0.0% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Ceiling 3: Cathedral Ceiling (no attic)
Wall 1; Wood Frame, 16" oc.
Window 1: Vinyl Frame:Double Pane with Low-E
Door 1: Solid
Door 2: Glass
Floor 1: AIbWood Joist/Truss:Over Unconditioned Space
2007 30.0 0.0 70
194 19.0 0.0 10
138 15.0 0.0 9
2244 13.0 0.0 154
232 0.330 77
37 0.300 11
93 0,310 29
2339 19.0 0.0 110
The proposed building represented in this document is (
with this permit application. The proposed systems
Code requirements. When a Registered Des
his/her knowledge, belief, and professional
Name - Title
07.136 Page I of I
REScheck Software Version 4.1.0
Inspection Checklist
Date: 10/23/07
Ceilings:
~1 Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[] Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above-Grade Walls:
Wall 1: Wood Frame, 16" c.c., R-13.O cavity insulation
Comments:
Windows:
Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Comments:
Yes No
Doors:
Door 1: Solid, U-factor: 0.300
Comments:
[] Door 2: Glass, U-factor: 0,310
Comments:
Floors:
[] Floor 1: Ali-Wood JoisCrruss:Over Unconditioned Space, R-190 cavity insulation
Comments:
Air Leakage:
[] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
[] Recessed lights are 1) Type lC rated, or 2) installed inside an appropriate air-fight assembly with a 0.5" clearance from
combustible materials, If non-lC rated, fixtures are installed with a 3" clearance from insulation.
Vapor Retarder:
r~ Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
[] Materials and equipment are installed in accordance with the manufacturer's installation instructions,
Materials and equipment are identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
¢-I insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
[] insulation is installed according to manufacturer's instructions, in substantial contact with the sur[ace being insulated, and in a
manner that achieves the rated R-value without compressing the insulation,
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to R-8.
Return ducts in unconditioned attics or outside the building are insulated to R-4.
Supply ducts in unconditioned spaces are insulated to R-8
07.136 Page 2 of 4
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
Duct Construction:
n All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), masfic-plus-embedded-fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. wg (500 Pa).
~1 The HVAC system provides a means for balancing air and water systems
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
Separate electric meters exist for each dwelling unit
Fireplaces:
[-~ Fireplaces are installed with tight fitting non-combustible fireplace doors.
Fireplaces have a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York
State, the Residential Code of New York State or the New York City Building Code, as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and out,et unless the water heater has an integral heat
trap or is part of a circulaling system
[~1 Circulating hot water pipes are insulated to the levels in Table 1
Circulating Hot Water Systems:
[~] Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
F~I HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
07136 Page 3 of 4
Tab/e 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Up to 1" Up to 1 25" 1 5" to 2.0" Over 2"
Temperature (°F)
170-180 05 1 0 1.5 2.0
140-169 0.5 0.5 10 1.5
100-139 0.5 05 05
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp
Piping System Types Range(OF)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature 201-250 1 0
LOW Temperature 120-200 05
Steam Condensate (for feed water) Any 1
Cooling Systems
Chilled Water, Refrigerant and 40-55 0,5
Brine Below 40 1.0
1.5 1.5 20
1.0 1.0 1.5
1.0 1.5 2,0
0.5 075 1,0
t.0 1.5 1.5
NOTES TO FIELD: (Building Department Use Only)
07136 Page 4 of 4
TOWN OF SOUTHOLD PROPERTY ,,RECORD CARD ""~'-'
OWNER STREET '~ ~
', .~ . '(,~ VILLAGE DIST. SUB.~,~ LOT~'r.._~r~
~: ~ ~S~S. VL. ~ FARM CO~. CB. MICS. : M~t. V=lue
~ND IMP. TOTAL DATE RE~RKS//~h~ ~/~/~ ~ ~ ~ J(~
rill:~le ~ FRONTAGE ON WATER
N~I:~ FRONTAGE ON ROAD
~ DEPTH / ~' 0 '
~ Plmt BULKH~D
COLOR
TRIM
Extension ,~? X
Extension
Po~ch
Ilorch
Potio
0.8.
T~al
Foundation
Basement
Ext. Walls
Fire Place
Type Roof
Bot~
Floors
Interior Finish
Heat
Rooms 1st Floor
Recreation Room Rooms 2nd Floor
Dormer Driveway
~'/~/~'
..~j,(, /?~. ~ LR.
~),.~, ,~ ,fc.J. DR.
inette
BR.
FIN. B
bot
~D
: ~ YOUNG & YOUNG
400 OSTRANDER AVEHUE, R)VERH[~AD NEW YORK
ALfJEN ~ YOUNG HOWARD W. YOUNG
SURVEYINLANDFOR:HoMES, tNC, ~,~: '" ' ' i.' :':"?~,': ,.~,. ~,
LOT NO. 2B,"LAUREL COUNTRY ES3~,5,TE$''
^~r LAUREL ~T~,~o '~o:
SOUTHOLD
SUFFOLK CO,, N.Y.
t" = 40' oA'r'~:~,~,,,~
~'PICAL ROOF CONSTRUCTION
'IBERGLA~S ROOF SHINGLES
5# BLDG. FELT
CE SHIELD A~ SHOWN
/2" PLYWOOD SHEATHING
%OOF P-JNFTEP-,5 A5 PER PLAN
:EILING JOISTS AS PER PLAN
R-30) INSUL.@ FLAT
R- I 9) INSUL @ CATH
/2" GYPSUM WALL BOARD
12
2' X 4" TOP EL.
WALK-IN
CLOD.
3/4" PLYWOOD
DUDFLOORING ( TCG )
CRAWL SPACE
RIDGE VENT
TYPICAL WALL CONSTRUCTION
VINYL SIDING
INFILTRATION BARRIER
I/2" PLYWOOD SHEATHING
2" X 4" STUD5 @ t G" O.C.
MATT INSUL. (R-I 3)
I/2" GYP. WALL DS.
I/2" ¢ THRU-DOLTS
EA R.R. / C.J. CONNECTION
I~ CATH CLG'5.
CLG. HT. ~ M. DDRM
2" X 4" R- l 9 INSUL.
@ I G" O.C. TECO~
BLOPED
I lb" GYPSUM WALL
DS. (~ WALL5 ¢,CLG.
DRG, WALL MASTER
BEDROOM
FLOOR. JOIDTD AD PEP,
PLAN TO ALIGN W/EXIST.
VAPOR 5ARRIER
TOP OF PM
TOP OF DUD FL ·
D" P.C. FOUNDATION WALL
2" X 4' CONT. NE'rWAY
SECTION A I/4"= I I-OH
FOR ADDITIONAL INFORMATION REFER TO SHEET 4
~) I/2" 0 THRU-DOLTS
) EA R.R. / C.J, CONNECTION
) CATH CLG'D.
;LC. HT. @ FAMILY Pdv~
12
DLIq'G AD R~Q'D
INSUL.
PAMILY RM
VENT
0" ~JDGE
PLAN W/TECC)5
DAF.
TOP OF PLK
fOP OF 5US FL.
2" X G'" NAILER
W/ TEGOD. REFER.
TO DETAIL 51dEET 4
5UDFLOORiNG ( T*G )
TO DE FLUSH W/~XIDT.
FLOOR JOISTS AD PER
pLAN TO ALIGN W/EXIST,
CRAWL SPACE
GRD AD pER. PLAN
5ECTION B I/4"= I I - 01'
FOR ADDITIONAL INFORMATION REFER TO SECTION ABOVE
TOP OF DUD FL.
GRADE
/5" P,C. FOUNDATION WALL
ON D" X I G" P.C. ErG. W'/
2" X 4" CONT. KEYWAY gYP.)
M. BATH HALL BATH KITCHEN
~,,1~ ~' ~'%'? I~,, 2,1
o [o u~v u,,v wc~ °~'l° DW.
SCHEMATIC
co
PLUMBING RISER
DIAGRAM
N.%5.
NEW ADDITION
NEW DECK
NEW ADDITION
REFER TO CORNER
HOLD DOWN DETAIL
BELOW
20'-7"
aII
8I'
5CR
?KT
CRAWL SPACE
2" P.C. SLAB OVER
VAPOR BARRIER
I'
7'- I 0" '-I
/,/NEW 2" X 8" FJ I 2.c.
TO BE FLUSH W
r
~l T,E ~LR To ~,ST.
STEP ~G,
2: I M~
TO
REMOVE EXIST. W1NDOW
~ROVIDE OPENING TO
NEW CRAWL 5PACE
( ~LUE
KELOCATEEXIgT. HTR
TOTH, LOC^T,ON
NOTE: PROVIDE 5/8"
TYPE "X" GYPSUM SD,
2" X I 0"
LINE OF DECK.
~/¢ STEP5 ABV
2" X
I (3) 2" X I0"
F.C. PIER
ON 24" X 24" X 12"
P,C FrG. (~¢PICAL)
NOTE: ALL LUMBER USED ~$1
DECR5 TO DE TPJ~ATED. ALL
HARDWARE TO DE GALV. I
REFERTO SHEET 5
FOR LEDGER SD. REMOVE D(IDT.
CONNECTION Gl
AR~A
2" X 8'"'LEDGER SD. W/TEC05
REMOVE ~(19T. F.J
~ CANTILEVER.
REMOVE ¢ RELOCATE
EXIST, HTR
@ BOILER AREA AD
PER CODE ( I O0 5J=,)
EXI5TING
0
EXISTING (3) 2"
O--
(3)
X
ADD ~ I 3/4" X 9 I/2" LVL ~TO EACH
IDE OF EXIST. GRD. USE I 2 LENGTH5%
REFER TO DETAIL BELOW
8I' GIRgER 0 -- ---- J
EXIST CELLAR
GIRDER
DLK. 50US UNDER
NEW POET ADV.
EXISTING
24'-2"
I G"I~ 8"
5CF-, ~ ENT
CRAWL 5PACE
2" P.C. 5LAD OVER
VAPOR BARRIER
I G" X 6" DLK PIER ON
24" X 24"X I 2' P,C, %
FOOTING (?FPICAD I I
2" X 8" FJ ~ I G'"~, ___.
TO DE FLUSH W/~XI,5't'
I
5CR \
//NEW 2" X 6" I 6
TO BE W/I~
8'-6" 5'- I O"
ENT
CORROSIVE T~ ~ TO ~IST. ~G.
~ICAD
TIE NEW ?ND WALL
EXIST CRAWL 5PACE
PROVIDE OPN'G TO
EXIST.
EXIST UNEXCAVATED
RETAIN STORM WATER mlNOFF
PURSUANT TO CI IA?~ cn 236
OF THE TOWN CODE.
~MOV[ ~X~ST.~ND
WALL TO ALLOW
FOR 10LO" OH DR
COMPLY W!TH ALL CODES OF
NEW YORK STATE & TOWN
As REQUlF .,,,ND
lJ //JJ SOL~OLOTOWNZBA
SOUTHOLD TOWN PLANNrNG 80ARS
.-~. 80UTHOLD TOWN TRUSTEES
NY,8, DEC
EXIST. F.J. ,
FOUNDATION FLOOR PLAN I/4"= I '-0"
EXISTING (3) 2" X 6"
TYPICAL FOUNDATION
8" POURED CONCRETE WALL ON
IG~' x 8" P.C. FOOTING W/2" x 4"
CONT, KEYWAY, (2) 2" x G" TREATED
DILL pLATED, 5ILL 5EAL, TERMITE
SHIELD ¢ DAMPPROOFING.
5/D"0 ANCHOR BOLT
OCCU, ' kIOY OR
USE 15 UNLAWFUL
WITHOUT CERTIFI(
OF O00UPANOY
APP~V~D AS NOTED
7BB-180~, 8AM TO 4PM EOR THE
FOLLOW~3 INSPECTIONS:
1. FOUND]~TION - TWO REQUIRED
' FgR P.~JRED CONCRETE
2. ROUGH - FRAMING & PLUMBING
3. INSULATION
4. FINAL - CONSTRUCTION MUST
DE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NBA
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
NAIL~ ~ GIi OiC,
PR~DEFLECTED
HOLDDOWN
(EITHER SIDE)
CERTIFICATION OF'
NAILING
¢~DERWRffERS CERT~OA~ TYPICAL CORNER
REQUIRED
--I
A L L C 0 N ST R L ~;~i(~¢sH(~
CODE~ OF N~ ry~F~K STAT
ON L~D CON~ :~BEFO~
OERTIFICA TE O~ ~UP~
' SOLDER USE[
~ATER
8UPPL Y SYST~ ~ANNO~
EXCEED ~I0 C ~'~ LEAD
THE
:.
COL, Bk"ON D
DETAIL
ADD I 3/4"X 9 I/2"LVL
TO EACH 5IDB. THRU-DOLT
W/ 1/2" ¢ DOLT5 @ I 2"
O.C, STAGGERED. U5E
I 2' LENGTH~.
SIMPSON OR EQUAL HOLDOWN5
TO DE PROVIDED AT CORNER5 OF
NEW BUILDING AND AT OPENING5
GREATER THAN GLO" WIDE DEE
DETAIL5 THI5 SHEET.
TYPICAL ANCHOR ~OLT5
5/8" I~ X 53II C.C. W/MINIMUM
EMDEDMENT OF 7" WITH 3" X
SQUARE WASHER, HOLD l 2" OFF
CORNER.5 AND 4" TO I 2]" OFF EACH
END OF EACH 5ILL PLATE. PROVIDE
LIpLIh-f 5TP-.A? CONNECTION5, SEE
DETAIL 51tEET # A-.
/
2'- I"
DH
Dd NAIL5 @ 4" O.C.
EDGE5
D~l NAIL5 ~ 4rI O.C, I LSd NAIL5 ~ 4" O.C.
A5 SHOWN -- ALL EDGE5
ELEVATIOIW VIEW
WAI ,l, BRACING DETAIL
HOLD-DOWN PLAN DETAIL r
~.,~ PLUMBING J Date: 10~24~07
A,L~,~.~" tll~ ~E sWNAESET~E m
I ~ n ML~rOJ # 07 13(;;
FND5 \ , TESnN~ SEFORECO, V~J.~;, ' '
PREDEEIZCTED HOLDDOWN ' -
(EITNER BIDE)
5/8" ¢ ANCHOR DOLT
CNW
COUPLER NUT5
coMPLy'WITH cHAPTeR 46
FLOOD
SouTHOU
Drwn. by: DKvTC
Chkd. by: dk
PROVIDE 51MPDON A55
NEW ROOF BHINGLEB
RIDGE VENT
NEW 2" X G" C,J. (~
I G" O.C, WJ TECOD
EXIDTING RA~TEP-.5
~15 INDUL NEW CLG.
F.
~ NEW LVL W/BR~.~/ tlJ : ........... ~-
KNEEWALL ABV I I REMOVE EXIBT. WALLS (' CLG.
TO RIDGE I I (MID A&~. ~PAI& FL,, * WAL~ ~
ii ~REQUI~D, MATCH NEW CONDITIONS ~
R~TCHEN ~ DINING ~OOM b
[~ '~
EXIDT. CEL~&
~iDT. COL
6KIBT. FTG.
SECTION C I/4" = I '-0"
GENERAL DEMOLITION NOTES:
I . FIROT FLOOR:
- REMOVE ALL WALLS. CEILING JOISTS, AND
ROOF P-,APTEP-,5 WHERE SHOWN.
- REMOVE ALL PLUMBING FIXTURES AND APPLIANCES
WHERE SHOWN.
- REPAIR EXISTING WALL5 TO RECIEVE NEW PARTITIONS
WHERE SHOVeN.
2. ALL PLUMBING, HVAC, AND ELECTRICAL COMPONNENTS TO
BE DISCONNECTED, CAPPED AND REMOVED OR REROUTED
AS REQUIRED.
3. ALL WINDOW5 TO BE REMOVED AND REPLACED AS PER PLAN.
REPAIR OPENINGS AS REQ'D. TO ACCEPT NEW OR RELOCATION.
4. CONTRACTOR, SHALL CLEAN AND PREPARE EXISTING ELOOR
TO BE READY FOR NEW FLOOR AND FINISHES.
EXIST, WALLO.
REQ'D)
AD REQUIRED. MATCH
)NDITIONB
~RIFY [
JTD. NOTIP¢
ir IE LAPPED
lB WALL.
EXIST. BEDROOM
20L7" NEW DECK 24'-2" NEW (BUILD THIS ROOF FIR`BT)
~L4" ~'0" ~'-4"
c 14 P4O4O c 14 WE) STEP5 W/H R NOTE: POST EA END
III ii ~-- TO GR`ADE AD REQ'E ] OF HD,°-. SOLID (TYP)
i (a)2,,~ io,, % ,
~- i i TW 2652 TW ~_~,52
i RAILING T (2) 2" × ,5" J (2) 2" X a" % / ~ ~
CLi~. ,, , ~F,C^U aO,.7,, 4,, ' ~ D'-~" b.&, a .,_0,, aJo,, .,,
~ c~o~. ~ ~z'x~"~.~.~tCo., ' ' ~ --
~ 8o u I 2"X&'IC.J, ~lG"ox // m i ~" ~ m
CbG. HT ~ D~ DOT. ~ 9'-6" A. =.~, ~ ~ ~ //2" X
~ ~ ~ ~ ' ~ 2"XS"C.J. ~16"o.c. // 6
~ ~ J I ~ CA~I~ A~V )J
-, ~ NEW DEC~ ~ '
m ~ m ~ ~ m
~ ~ , m // 5/4" DECKING ~ m CT~. W. N~E= VENT
~ m m - mm ~ :AD'5 A
~LO" m m ~ m m ~ ~10~
~ m m ~ , ~AM reLY ~OOM m
, , ~ ,
.."m
¢ m ~ 4" X
~ mm ~ C ~ m ~ m ~ ~ 3LO"
m ~ ~ 4,, 2'( O. ~,, 3,-~" ~,,
I ~ ~ ~ ~ (!~ 2" X I O' '~ NLGD33G~5 NLGDGOG~R NLGD33G~5 m
)m
o ~ O~ o ~,~ · ~: DINING ROOM 0 N m
~ ' '~>~ ~ o ~"x ~"d
~ ~ xx ~ ~ % 12'-0"/~,, ,2'-0 ? 4'-3" ,4" ~ 5 k 20'-7 J 4"~ I
-~ f ~ %~MOVE~ST.C.J. ~ J ' ~
- --' ~ '--'~-' ~ ...... m~ ----~1 ~¢t~"A~ WlT[,:05~-- -- ~-~
D~D~OO x ~ ~ u~w ~OLO ~S ~ ~ ~ LVL
~ _~ ~ ~ D~D~OOM ~ " _~ ~ ~ITCH~N ~ ~ ~ ~I~T, GA~G~ o°
~ ' ~ ' ~ ~°O~O 'd ~
~= '.,~ 50 C~M~'P' x mm (2) Z" X l 2": (2)~mm302 I 0 ~" ....... ~ - ~/~EW 2,m-~,, ~7 ~ ........ ~-~ z
~ ~ ~ IG"~'C'OV~F"
4" 2'¢' 4" I~'-0" 4' ~ 5'-0" ~ 4" P.C. FA~ ~ ~ ~
'~~, ~ e (2) m 3/4"X 9 )/2" LVL
(2) 2"X I0"~ --~ ~ -ju ~=
(2) TW3042 (3) 3C ~2 OVE ~IBT,~NDO~. ~ ~ER TO
INSTALL NEW ~ SHOWN D~AIL
,;
I 0'-¢" I ¢-¢" 3LO" ~ 6'-2" J 2'- I" ~ 2'- I"
24'-2" +/- ~lBT.
4,_6,,, 2 I ,.4,, +/. ~lBT. I ¢'- I O" +/- ~lBT,
64L4" ~IBTING
REMOVE EXIST. BATHRM ~REPAIR FLOOR AD
FIXTUREB. CAP OFF ALL / FREQUIRED TO MATCH REMOVE EXIST. WALLS,
PLUMBING. REPAIR / EXISTING /CLG. ¢ ROOF THIB AREA.
FLOOR AD REQUIRED / /REPAIR PL., * WALLO AD
~ - CHIMNEY NEW CONDITIONS
DINING II KITCHEN EXIBT.
I[ FAMILY Rivl.
R~MOVE EXIST. CLG,
THIS AREA.
EXIBT.
GAP. AGE
~-r -~/ '~ WALLS. REPAIR PLO
/il H AB R~QUIRED
BEDROOM II
II EXIBT. BEDROOM
)H
NOTE: CLOTHED DRYER D(~AUD'T TO BE
INOTALLED IN ACCORDANCE WiTH ~ECTION
I 501 OF Tiff E REglDENTIAL CODE OP NEW YORR
NOTE; VENT N '~'
EXTERIOR
4" X 4" PC~TO
¢//GALV. CAP ¢
BADE ANCHOP, O ·
ALL BRACING
REMOVE ID(mDT.
RXTUREB. CAP OEP
ALL PLUMBING. REPAIR
FLOOR AD REQUIRED
REMOVE EXIST. OH DOOR
MAKE OPN'G W1DER TO
ACCEPT NEW ~0' OH DR.
FIP-,,BT FLOOP-, PLAN I/4" = I I-0"
EXIST. AREA CALC.
FIRST FLOOR.: 1342,5.F.
GARAGE: 361 .5.F.
TYPICAL WINDOW/PATIO DOOR NOTE:
ALL WINDOWS ¢ EXTERIOR PATIO DOORB ARE TO DE
MANUEACTURED BY ANDEROEN. DERIEB 400. WHITE
PERMADHIELD, HIGH PERPORMANCE LOW E
GLAZING,BCREENB, BTANDARD HARDWARE. PROVIDE
EULL WALL WlDTfl E3~TENBION JAMBB AS REQ'B,.
PROVIDE FACTORY INBTALLED MULLIONB AB RfQ'D..
ALL UNITS TO HAVE A MIN. DP SO RATING, INBTALL ALL
UNITS AD PER MANUFACTURE'B BPECB.
FLOOR, AREAO:
F___XIOT.FII~OT FLOOR`: 1342 O.F.
NEW CONOTR`UCTION: 997 5.F
TOTAL:
GARAGE (EXIST):
P-.EA P.. DECK:
2339 5.F.
36 1 5.ff.
412 5.F.
WALL LEGEND
EXIST. TO REMAIN
TO BE REMOVED
NEW 2" X FRAMING
(AB NOTED ON PLAN)
NEW END. WALL
]
E ]
zrV' z
0 j
Date: 10/24/07
Proj. #: 07.136
Drwn. by: DK/TC
Chkd. by: dk
sheet no.
2
DEMOLITION PLAN I/4" = I '-0"
PL, HT
BUBPL
NOTE:
REMOVE EXISTING ROOf= SHINGLES AND SIDING.
INSPECT AND REPLACE ANY DETERIORATED
SHEATHING. INSTALL NEW MOISTURE BARRIERS,
SIDING AND SHINGLES.
~PL. HT.
~BUBFL.
2LO" ~ OCREENED
LOUVERED VENT
ROOF BHINGLE5 L/./~ RIDGE VENT
I 2 -I 2-- DECOI~ATIVE
:- -i ' rli, -I' Il
,' , = = ,/ ,J I ~ I DEC01 ~TIVE BHLFFFER,5
· I I ~ I ~ FR.( ,~T ELEVATION
~555~5~~ ///// '~ ~[~ -- I //~" I i /~'~P (~OW~
I r REMOVE ~IST. % // NEW VIN% SIDING ~ DECO~TIVE PANE~ ~MOVE ~IST, ~MOVE ~IDT, / UFW ~/lU~ qrnlkl~ /
SHOWN)
WINDOWS. PILL OPN'G WINDOW~ WINDOW5
FLUBH BOTH BIDEB
NEW EXIBTING EXIBTING ~ISTING
I
STEP ~G
FRONT ELEVATION I/4" = I '-0"
12"¢ P.C. PIER
3' BELOW GRADE
TYPICAL
NOTE:
NEW VINYL SIDING ENTIRE HOUSE
NEW ROOF SHINGLES ENTIRE HOUSE
NEW ADDITION
NEW DECK
NEW ADDITION
TPL. HT.
~BUDF
ROOF BHINGLE5
L.~ RIDGE VENT
2' ,Q" ~ .m. CREENED
BLIND
RIDGE HT
I G" X B"
VENT
VINYL BIDING
3' HIGH RAIUG W/ F WD STEP5 W/HR
2" X 2" DALU,STER5 TO GRADE AD REQ'B I
~ @ 5" O,C. (TYP) L FLJq ~ J~ ~
~ ON 24" X 24" X I 2" -- -- STEP FTG STEP FTG ~
j P.C. FTG. (lh'PICAL) 2:1 MAX 2:1 MAX j
REAR
5TE?FTG
ELEVATION I/4"= I '-0"
PL. HT.
BUDFL. ~
GP-,ADE
EXXIBTING REBIDENCE NEW ADDITION
NEW ADDITION EXISTING R[51DENCE
BLIND
PL. HT, 0
NEW I O' X 7' OH DOOR I ,, I
VIN% 51DING VINYL 51DING ,% ~ Date: 10/24/07
5U~FL. ~ Proj, ~: 07.13G
G~DE
VENT ~ILL OPN'G PLUSH BOTH J ~EMOVE ~IDT. ¢' OH DR WD 5TEP5 W/H~ J 5CR VENT
51D[5 ~ ~Q'P T,'O ACCE~ * ~P~CE W/ I O' OH DK TO G~DE ~ ~Q'q I J L
ak
-- L ~ _ 3' BELOW G~DE
STEP ~G I ] J ~ICAL) no.
LEFT
SIDE ELEVATION I/4" = I '-0" RIGHT 51DE ELEVATION I/4" = I '-0" 3
CONDTP--.UCTION NOTE5
ENERGY NOTE5
EGR. E55 WINDOW SCHEDULE
(ALL 5LEERING ROOMS)
SAFETY GLAD5 REQUIP-ZMENT5
AFCPA WOOD FP-,AME CONSTRUCTION 1:395 EDITION
FASTENER SCHEDULE FOR 5TIRUCTUP-,AL MEMDER5
NUMBER AND TYPE SPACING OF FASTENER8
DESCRIPTION OF BUILDING ELEMEHTS OF FAETENER
ROOF FRAMING
BLOCMNG TO JOIST, TOE NAILED 2-8d EACH END
~LOCEING TO 5ILL OR TOP PLATE ( TOE NAILED) 3- I Gd EACH BLOCK
LEDGER STRIP TO BEAM (FACE- NAILED) 3-I Ga EACH JOIST
JOIST ON LEDGER TO DRAM (TOE NAILED) 3-8d DER JOIST
DANE JOIST TO JOIST, END NAILED $-I 6d PER JOIST
DANE JOIST TO SILL OR. TOP PLATE (TOE NAILED) 2- I Gd PER FOOT
SOLE PLATE TO JOIST OP. BLOCKJNG. FACE NAIL (~1 J ~ I 2" O.C.
G.W.B. j 5J::tCOOLER~ I 7"EDGE/ IOI'FIELD
4" FOR ATTACHMENT OF ROOF 5HEATHrNG TO GADLE WALLS.
2" X 2" DALISTER5 l/2" CDX ROOF SHEATHING RIDGE BEAM A~ PER PLAN
~ 5" O.C HOLD PLYWOOD DACE FROM
RIDGE EOR AIR CIRCULATION CAP SHINGLE
AT RIDGE VENTS CONTINUOUS PJDGE VENT
AS PER PLAN BUILDING FELT (SEE PLAN)
NAILED TO JOIST5 ROOF SHINGLES
PEK PLAN
PROVIDE HANGERD@ I 1/4" x 200a BTEEL STRAP EVERY
CATH CLG'B (4) Scl NAIL~ EACH END, C.T.rS ~ 32" O.C.
OK
DECKING ~LLAR TIE5 @ I G' O.C. MAY DE SUBSTITUTED
~ D~CKJOISTS~PERP~N ~ ~ ~
POST ANCHOR. '~ (5} 8d ~ ~E~ ~. CONN~O~
SIMPSON PD 5E~E5 (5) 6d ~ P~TE EA. CONNE~O~
(~ TO TOP P~Tm)
DECK DETAIl, (CLG. JTS.) ~F~ TO T~-DO~ / CONN[CO~ e ] 6" O.C.
C~20 5T~PS.HDE TO STUD, (5) Cd ~ P~TE
~ AND
FOUNDATrON WALL
JOIST HANGER --
PROVIDE I¢
¢ 1 6" O.C, STAGGERED ¢
DOUBLED @ EA END @ EA
LEDGER ED. CONNECTION
TYPICAL DECK FRAMING DETAIL
AT EACH CRIPPLE 5TUD.
TOP AND BOTTOM
-- PHD5 HOLDOWN REQ'D
AT ALL OPENING5
GLO" WIDE ¢ GP, J~ATER
,STUD TO
BTUD,
5/&' 0 ANCHOR BOLT @
DB" O,C, HOLD G" - I 2"
OFF EACH END OF EACH
SILL PLATE.
MIN, EMBEDMENT 7" INTO
CONCRETE
16" O.C. (5) IOd NAIL~ EACH END*
LTP4 5ILL PLATE TO RIM JOIST. ( I 2) ,~d
OR
C520 5TRAPS ~ I 6' O.C.
RUN UNDER BILL PLATE5 AND UP
STUD, MINIMUM (4) I Od NAIL5
~JkCH END
OR BTUD TO BILL @
0.C.(5) I Od NAIL~ ~ EACH TIE DOWN /FOUNDATION DETAIL
END,(42" LONG MIN.)
TYPICAL HEADER OPENING
CLIMATIC AND GEOGP-,APHIC
DESIGN CRITERIA
GROUND 5NOW 45 PDF
LOAD
WIND SPEED
120
(re?h)
SEISMIC DEDIGN
CATEGORY C
WRATH- 5¢VERE
ERING
FRODT
~UDJEc'r UNE ~'-0"
TO
DAMAGE TEE. MITE MOD-TO
FROM HEAVY
5LrGHT TO
DECAY MODERATE
UNDERLAY- YES
CODE ANALYSIS
ASPHALT ROOF SHINGLE NOTE
ASPHALT SHINGLES SHALL HAVE SELF- SEAL STRIPB OR. DE
INTERLOCKING, AND COMPLY WITH ASTM D 225 OR D 3462.
2. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL,
STAINLESS, ALUMINUM, OR COPPER ROOFING NAILS. MINIMUM
12 GAGE 5HANIC. ED WITH A MINIMUM 3/8 INCH DrAM~ER HEAD,
OF A LENGTH TO PENET~kTE THROUGH THE ROOFrNG MATERIAL5
AND SHEATHING.
3. ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUM~SER OF G
EASTENE~5 REQUIRED DYTHE MANUFACTURER. ( G MTN.)
4. FOR. NORMAL APPLICATION, ASPHALT SHINGLES SHALL BE
SECURED TO THE ROOF WITH NOT LESS THAN SIX F~STENER5
PEP. STRIP SHINGLE OR TWO FASTENER..5 PEP-. INDrVIDUAL 5HINGLZ.
5. ROOF COVE~.ING MATERIAL~ (SHINGLES) SHALL DE DELIVERED IN
PACF. AGES BEARING THE MANUFACTURES IDENTIFT]NG MARF.5,
Da~e: I 0/24/07
Proj. #: 07.136
Drwn. by: Dr,/I-C
Chkd. by: dk
~heet no.
4